1
|
Lessons learned after three years of SPIDER operation and the first MITICA integrated tests. FUSION ENGINEERING AND DESIGN 2023. [DOI: 10.1016/j.fusengdes.2023.113590] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/27/2023]
|
2
|
Study of beamlets extracted from a multi-aperture and five-stage acceleration system. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:053301. [PMID: 35649793 DOI: 10.1063/5.0080804] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Accepted: 03/12/2022] [Indexed: 06/15/2023]
Abstract
A beam optics study using the ITER-relevant high intense negative ion beams, such as 1 MeV, 200 A/m2, has been performed experimentally and analytically using a multi-aperture and five-stage accelerator. Initially, multi-beamlets generated from this accelerator were deflected in various directions due to the magnetic field and space charge repulsion between beams and showed various divergences. These had limited the pulse length and the beam energy. Compensation methods of the beamlet deflections have worked effectively and contributed to achieving the ITER requirement, the divergence angle of <7 mrad, and the deflection angle of <1 mrad for 1 MeV beam. The beam pulse has been gradually extended from 1 to 100 s and is now going to a longer pulse based on these results. One of the remaining issues is to understand and suppress peripheral components of the beam, namely, the halo, and to reduce the local heat loads observed around the aperture edge. This halo component has been successfully distinguished from the beam core by using a newly developed beam emittance measurement system for high intense beams. By combining this measured beam emittance and the beam simulation, it was clarified for the first time that the halo components are generated in an area of 1 mm width from the aperture edge.
Collapse
|
3
|
Impact of transcatheter aortic valve implantation on coronary flow reserve by transthoracic Doppler echocardiography 1-year after the intervention in severe aortic stenosis patients. Eur Heart J 2021. [DOI: 10.1093/eurheartj/ehab724.1636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Coronary flow reserve (CFR) which is one of indexes reflecting coronary microcirculation in patients without significant epicardial coronary lesions can be impaired in patients with severe aortic stenosis (AS). It has been shown that CFR is an independent predictor for future cardiovascular events in AS patients. Transcatheter aortic valve implantation (TAVI) has rapidly become widespread and is becoming the standard treatment for severe AS. This procedure may have a good effect on CFR due to reduction of severe afterload in patients with severe AS. Although the recent reports evaluated change in CFR immediately and 6 months after TAVI, it has not been evaluated whether impaired CFR improves 1-year after TAVI in AS patients with preserved left ventricular ejection fraction (LVEF).
Purpose
The purpose of the present study was to investigate whether impaired CFR improves 1-year after TAVI in severe AS patients with preserved LVEF.
Methods
The study population consists of consecutive 105 patients with severe AS undergoing TAVI. Exclusion criteria were atrial fibrillation, old myocardial infarction, history of coronary artery bypass grafting, significant lesions in the left anterior descending artery (LAD), moderate or severe mitral valve disease, history of valve replacement, LVEF <50% and preoperative CFR >2.2. CFR was obtained from coronary flow velocity by transthoracic echocardiography at rest and maximal hyperemia in LAD before, immediately and 1-year after TAVI. We compared CFR between before and after TAVI in the study patients who did not meet the exclusion criteria.
Results
After exclusion of 76 patients who met the exclusion criteria, the final study patients consist of 29 patients (8 male, 84.9±5.2 years). There was no significant difference in LVEF (61.3±3.4% vs 61.6±4.4%, P=0.667) and LV end-diastolic volume (LVEDVI; 58.2±9.2 mL/m2 vs 55.8±9.0 mL/m2, P=0.089) between before and immediately after TAVI. LVEF (61.0±2.8%, P=0.721) and LVEDVI (58.0±9.1 mL/m2, P=0.949) 1-year after TAVI were similar to those before TAVI. There was no significant difference in coronary flow velocity at rest between before and immediately after TAVI (27.4±8.9 vs 24.4±7.0 cm/s, P=0.051) and between before and 1-year after TAVI (25.9±8.3 cm/s, P=0.396). Coronary flow velocity at maximal hyperemia 1-year after TAVI significantly increased compared with that before TAVI (from 48.8±13.9 to 67.9±21.0 cm/s, P<0.001) while there was no significant difference between before and immediately after TAVI (52.0±12.0 cm/s, P=0.186). Impaired CFR before TAVI (1.82±0.28) increased immediately (2.03±0.39, P=0.009) and 1-year after TAVI (2.69±0.57, P<0.001).
Conclusions
The present results suggest that impaired CFR in patients with preserved LVEF improves 1-year after TAVI. TAVI may have a good effect on CFR in severe AS patients with preserved LVEF.
Funding Acknowledgement
Type of funding sources: None.
Collapse
|
4
|
On the road to ITER NBIs: SPIDER improvement after first operation and MITICA construction progress. FUSION ENGINEERING AND DESIGN 2021. [DOI: 10.1016/j.fusengdes.2021.112622] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
5
|
Correction to: Radiofrequency identification tag system improves the efficiency of closed vitrification for cryopreservation and thawing of bovine ovarian tissues. J Assist Reprod Genet 2020; 38:543. [PMID: 33377999 DOI: 10.1007/s10815-020-02039-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
6
|
105P Dynamic change in blood derived variant allele frequency as a predictive marker for response from checkpoint inhibitor based therapies among metastatic solid tumours. Ann Oncol 2020. [DOI: 10.1016/j.annonc.2020.08.226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
7
|
Analysis of the cesium distribution in the JT-60SA negative ion sources for steady long-pulse operation. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:033313. [PMID: 32259933 DOI: 10.1063/1.5131103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Accepted: 02/27/2020] [Indexed: 06/11/2023]
Abstract
To realize stable negative ion beams for 100 s required in the neutral beam injector of JT-60SA, a physical model to control cesium (Cs) distribution inside the negative ion source has been developed in order to maintain the stable negative ion production at the plasma grid (PG) surface with Cs. In this work, to quantitatively evaluate Cs coverage on the PG, a three-dimensional Cs transportation code was introduced to consider the spatial Cs distribution in the source. The spatial temperature distribution of the chamber wall was also introduced in this model. As a result, the reasonable variation of the Cs coverage for 100 s was obtained, compared to that in the initial model. Based on the modified model, the operational temperature of the chamber wall was proposed to be less than 60 °C to suppress the desorption of Cs in the chamber wall and to sustain the stable negative ion production. In addition, it was also suggested that a slightly higher wall temperature before the operation leads to a decrease in the amount of Cs stored at the chamber wall, resulting in suppression of Cs consumption in the ion source.
Collapse
|
8
|
Achievement of stable negative ion production with Cs-seeded for long pulse beam operation in the prototype of Cs-seeded negative ion source for JT-60SA. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:023502. [PMID: 32113455 DOI: 10.1063/1.5130436] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Accepted: 01/13/2020] [Indexed: 06/10/2023]
Abstract
Long pulse negative ion beams of 500 keV and 154 A/m2 for 118 s have been achieved for the first time, which exceeds the requirement of the JT-60SA negative ion source. In order to solve the issues of such long pulse beams, the fast cutoff system of the power supply aims to reduce the surge current and to extend the lifetime of filaments and the suppression method of excess cesium (Cs) accumulation on the plasma grid (PG) to achieve stable negative ion production. By developing the fast cutoff system using a field programmable gate array unit for the arc power supply, the cutoff time has been reduced to 1/10 that of the original system and the lifetime of the filament was extended by three times. In order to achieve stable negative ion production, incoming Cs on the PG surface has been reduced by keeping the chamber wall temperature below 40 °C. As a result, a stable beam current drift of <6% has been achieved for the 118 s duration.
Collapse
|
9
|
Achievement of high power and long pulse negative ion beam acceleration for JT-60SA NBI. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:023506. [PMID: 32113410 DOI: 10.1063/1.5131302] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Accepted: 01/16/2020] [Indexed: 06/10/2023]
Abstract
Long pulse acceleration of hydrogen negative ion beams with the power density over 70 MW/m2 and the pulse length over 100 s has been demonstrated for the first time by using a multi-aperture 3-stage accelerator. Such long pulse acceleration was achieved by integrating the design of beam optics and voltage holding capability to meet the requirements of JT-60SA. By using the newly designed accelerator for JT-60SA, voltage holding at 500 kV with beam acceleration was stably sustained even after 5 g of cesium was seeded, and heat load on each acceleration grid was reduced below the allowable level for long pulse, less than 5% of total acceleration power. As a result, 500 keV, 154 A/m2 for 118 s beam acceleration was achieved, which satisfies the requirement of the negative ion source for JT-60SA. This pulse length of such high-power density beams is longest in the world. In addition, the result contributes to the long pulse acceleration of multi-stage electrostatic accelerators, such as 1 MeV negative ion accelerator for ITER.
Collapse
|
10
|
First operation in SPIDER and the path to complete MITICA. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:023510. [PMID: 32113382 DOI: 10.1063/1.5133076] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2019] [Accepted: 01/22/2020] [Indexed: 06/10/2023]
Abstract
The requirements of ITER neutral beam injectors (1 MeV, 40 A negative deuterium ion current for 1 h) have never been simultaneously attained; therefore, a dedicated Neutral Beam Test Facility (NBTF) was set up at Consorzio RFX (Padova, Italy). The NBTF includes two experiments: SPIDER (Source for the Production of Ions of Deuterium Extracted from Rf plasma), the full-scale prototype of the source of ITER injectors, with a 100 keV accelerator, to investigate and optimize the properties of the ion source; and MITICA, the full-scale prototype of the entire injector, devoted to the issues related to the accelerator, including voltage holding at low gas pressure. The present paper gives an account of the status of the procurements, of the timeline, and of the voltage holding tests and experiments for MITICA. As for SPIDER, the first year of operation is described, regarding the solution of some issues connected with the radiofrequency power, the source operation, and the characterization of the first negative ion beam.
Collapse
|
11
|
P91 Prognostic value of tissue-tracking mitral annular displacement by speckle-tracking echocardiography in asymptomatic patients with aortic stenosis with preserved left ventricular ejection fraction. Eur Heart J 2020. [DOI: 10.1093/ehjci/ehz872.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Background
Management of asymptomatic severe aortic stenosis (AS) patients with preserved left ventricular (LV) ejection fraction (EF) remains controversial. Recent studies using have shown that decreased LV longitudinal deformation assessed by global longitudinal strain analysis can predict adverse cardiac events in AS patients with preserved EF. Tissue-tracking mitral annular displacement (TMAD) by speckle-tracking echocardiography provides rapid and simple assessment of LV longitudinal deformation even when the acoustic window is poor (Fig.1).
Purpose
The purpose of this study was to examine the value of TMAD to predict occurrence of the cardiac events in asymptomatic severe AS patients with preserved EF.
Methods
We studied 103 patients with severe AS and preserved EF [aortic velocity >4m/s or aortic valve area (AVA) <1.0 cm2, EF >50%]in whom TMAD was measured, and a total of 44 patients were included in the final data setaccording to the exclusion criteria. Using TMAD analysis software, the base-to-apex displacement of automatically defined mid-point of mitral annular line in four-chamber view was quickly assessed, and the percentage of its displacement to LV length at end-diastole (%TMAD) was calculated (Fig.1). We investigated the association between %TMAD and the cardiac events including implementation of hospitalization due to heart failure, decreased EF (< 50%), aortic valve replacement or transcatheter aortic valve implantation due to appearance of symptoms and cardiac death,
Results
In all the final study patients, %TMAD was successfully and quickly (within 10 seconds) evaluated. During a follow-up, the cardiac events developed in 16 (36%) of 44 patients. Tableshows echocardiographic parameters in patients with and without the cardiac events. %TMAD was significantly impaired in patients with the cardiac events compared with those without the cardiac events (9.6 ± 0.6 vs 12.1 ± 0.4%, p= 0.002). The other parameters were not involved in the event occurrence; age, LV mass index, EF, aortic velocity, AVA, tricuspid regurgitation pressure gradient (TR-PG), early diastolic /atrial filling velocity (E/A), early diastolic velocity of the mitral valve annulus (e’) and E/e’. In multiple variable analysis, %TMAD was an independentpredictor of the cardiac events (HR; 12.1, p= 0.001). ROC analysis revealed that the area under the curve of %TMAD was 0.81 for the cardiac events. Kaplan-Meier analysis showed %TMAD (cut-off: 11.9) provides a significant difference in the cardiac event (Fig. 2). Conclusions. The present results suggests that TMAD easily and rapidly estimated by speckle-tracking echocardiography can be used as a simple method to predict occurrence of the cardiac events in asymptomatic severe AS patients with preserved EF.
Abstract P91 Figure 1,2 and Table
Collapse
|
12
|
Experimental investigation of the Cs behavior in the cesiated H - ion source during high power long beam operation. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:013513. [PMID: 32012574 DOI: 10.1063/1.5130430] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Accepted: 12/27/2019] [Indexed: 06/10/2023]
Abstract
The behavior of the Cesium (Cs) in Cs-seeded negative ion sources has been investigated experimentally under the beam accelerations of up to 0.5 MeV. The pulse length was extended to 100 s to catch the precise variations in the Cs D2 emission, discharge power, negative ion current, and temperatures in the ion source. The variations of the negative ions were estimated by the beam current and the heat loads in the accelerator. This experiment shows that the buildup of temperature in the chamber walls lead to the evaporation of deposited Cs to enter the plasma region and influenced H- ion production. The H- ion beams were stably sustained by reducing the temperature rise of the chamber wall below 50 °C. A stable long pulse beam could be achieved through the temperature control of the surfaces inside the source chamber walls.
Collapse
|
13
|
Radiofrequency identification tag system improves the efficiency of closed vitrification for cryopreservation and thawing of bovine ovarian tissues. J Assist Reprod Genet 2019; 36:2251-2257. [PMID: 31691057 DOI: 10.1007/s10815-019-01599-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Accepted: 09/26/2019] [Indexed: 11/28/2022] Open
Abstract
PURPOSE A radiofrequency identification (RFID) tag system was designed to streamline cryopreservation and thawing procedures. This study evaluated the usefulness of the RFID tag system for improving the efficiency of cryopreserving/thawing bovine ovarian tissue by the closed vitrification protocol. METHODS Six participants carried out closed vitrification and thawing of bovine ovarian tissues procedures using either the conventional or the new RFID tag method, and the time required to perform each step of the respective methods was measured. After normality of data was confirmed by the Shapiro-Wilk test, the significance of differences was assessed by the unpaired t test. RESULTS When closed vitrification was performed, the time required for each step showed a significant difference between the two methods (t(4) = 2.938, p = 0.042, d = 2.40), and the total cryopreservation time was 11 min shorter using the RFID tag system. When thawing was performed, the time required for each step also showed a significant difference between the two methods (t(4) = 2.797, p = 0.049, d = 2.28), and the total thawing time was 2 min shorter using the RFID tag system. CONCLUSION The RFID tag system tested in this study seems to be suitable for managing biological samples stored in liquid nitrogen. Adoption of an RFID tag system by fertility centers may not only improve the efficiency of cryopreserving/thawing reproductive tissues but could also reduce human error.
Collapse
|
14
|
P2700Impact of instantaneous wave-free ratio on graft failure after coronary artery bypass graft surgery. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz748.1017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Background
It has been reported that preoperative fractional flow reserve (FFR) is associated with graft patency after coronary artery bypass graft (CABG) and the patency is excellent when a bypass graft is anastomosed on a vessel with positive FFR. However, the association with graft patency has not yet been investigated in its novel counterpart, instantaneous wave-free ratio (iFR), and iFR sometimes contradicts FFR results.
Purpose
The purpose of this study is to assess an impact of preoperative iFR on a graft failure after CABG in patients with coronary arteries showing positive FFR (≤0.80).
Methods
We retrospectively identified patients who had undergone preoperative coronary angiography in conjunction with resting and hyperemic intra-coronary pressure measurements, CABG, and graft evaluation by coronary computed tomography angiography. After excluding vessels with negative FFR (>0.80), vessels were divided into two groups: negative iFR group (iFR >0.89) and positive iFR group (iFR ≤0.89). The rate of graft failure within 1 year after CABG was compared between the two groups.
Results
We analyzed 131 vessels in 89 patients (35 vessels in the negative iFR group and 96 vessels in the positive iFR group). The negative iFR group showed significantly higher iFR (0.92±0.02 vs. 0.74±0.13, P<0.0001) and FFR (0.72±0.06 vs. 0.63±0.09, P<0.0001) than the positive iFR group, although percent diameter stenosis (%DS) was comparable (57±10 vs. 56±9, P=0.47). The graft failure significantly often occurred in the negative iFR group than in the positive iFR group (28.6% vs. 8.3%, P=0.0029). In order to reduce the imbalance in the baseline characteristics except for iFR, 70 vessels were selected by using propensity score matching (n=35 in each group). The propensity score matched vessels also demonstrated significantly higher rate of graft failure in the negative iFR group than in the positive iFR group (28.6% vs. 5.7%, p=0.026) despite much more balanced FFR (0.72±0.06 vs. 0.69±0.07, p=0.02) and %DS (57±10 vs. 57±9, p=1.000).
Conclusions
Even when FFR is positive, the graft failure is likely to occur when a bypass graft is anastomosed on a vessel with negative iFR compared to a vessel with positive iFR.
Acknowledgement/Funding
None
Collapse
|
15
|
P3387Cholesterol crystals in superficial plaque layer detected by optical coherence tomography as a new morphological feature for plaque rupture. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz745.0263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Background
While plaque rupture (PR) is the leading cause of acute myocardial infarction (AMI), other etiologies are also involved in the onset of AMI. Cholesterol crystals (CCs) are usually present abundantly in atherosclerotic plaques, especially in the culprit site of AMI. However, the relationship between in vivo CCs and PR is unclear. Optical coherence tomography (OCT) is a high-resolution imaging technique that allows for the in vivo identification of various plaque characteristics including PR and CCs.
Purpose
The aim of this study was to investigate prevalence and distribution of CCs between patients with AMI with PR, AMI without PR, and SAP.
Method
This study consisted of 146 patients with coronary artery disease (AMI with PR; n=64, AMI without PR; n=41, and SAP; n=41) who underwent OCT prior to percutaneous coronary intervention. Plaque characteristics in OCT images were assessed according to the consensus document. We classified the distribution of CCs as follows; superficial type CCs were defined by any of the CCs invading the fibrous cap and remaining CCs as deep type CCs.
Result
There was no statistical difference in clinical characteristics among the three groups. The % diameter stenosis was significantly smaller in the SAP group than others (AMI with PR 91±12% vs. AMI without PR 86±13% vs. SAP 65±9%, p<0.001). The prevalence of CCs was significantly higher in the AMI with PR group than others (AMI with PR 78% vs. AMI without PR 41% vs. SAP 39%, p<0.001). The prevalence of superficial type CCs was significantly different among the groups (AMI with PR 72% vs. AMI without PR 24% vs. SAP 7%, p<0.001). Multivariable logistic analysis demonstrated that lipid plaque (OR 84.5, 95% CI [6.30–11332.33], p<0.001) and superficial type CC (OR 9.5, 95% CI [2.61–34.89], p<0.001) were independent predictors of PR.
Conclusion
Plaque with CCs invading the fibrous cap is frequently associated with PR in patients with AMI, suggesting. In vivo CC detection is a new morphological feature for plaque rupture.
Acknowledgement/Funding
This study was supported by a grant from JSPS KAKENHI (17K09557).
Collapse
|
16
|
P2453Value of pre-operative left atrial minimum volume as a surrogate for post-operative symptoms in patients with aortic stenosis who underwent aortic valve replacement. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz748.0785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Previous reports have shown that symptoms after aortic valve replacement (AVR) are not uncommon depending on severity of myocardial fibrosis in patients with severe aortic stenosis (AS). Pre-operative minimum left atrial volume (LAVmin) at end-diastole determined by direct exposure of left ventricular end-diastolic pressure may be used as a surrogate for post-operative symptoms in patients with severe AS undergoing AVR.
Purpose
The purpose of this study was to examine the value of pre-operative echocardiographic LAVmin index (LAVImin) to predict post-operative symptomatic status after AVR in patients with severe AS.
Methods
The study population consisted of 219 patients with severe AS who underwent AVR and were followed up for 1000 days after AVR. Pre-operative maximum LAV index (LAVImax), LAVImin, LA emptying fraction (LAEF), LV volume indexes, LV ejection fraction (LVEF) by biplane Simpson's method, aortic valve area index (AVAI), mean aortic valve pressure gradient (mAV-PG), E/A, mean E/e' from LV inflow and mitral annular velocity, and pulmonary artery systolic pressure (PASP) were evaluated by Doppler echocardiography.
Results
After exclusion of 136 patients who met the exclusion criteria (atrial fibrillation, significant coronary artery disease, significant mitral valve diseases, pacemaker rhythm, and inadequate echocardiographic images), the final study population consisted of 75 patients (75±7 years old, 46 female). During a follow-up, 19 patients (25%) complained post-operative symptoms. There were no significant differences in pre-operative serum hemoglobin, creatinine, BNP, chronic obstructive pulmonary disease, hypertension, diabetes, LV volume indexes, LVEF, AVA, mAV-PG between patients with and without post-operative symptoms. There were significant differences in pre-operative LAVImax, LAVImin, and LAEF between patients with and without post-operative symptoms. (60±15 vs 47±15 ml/m2, 45±15 vs 28±1 ml/m2, and 29±12 vs 42±11 ml/m2, respectively). E/A, mean E/e', and PASP in patients with symptoms were significantly greater compared with patients without symptoms (1.0±0.3 vs 0.7±0.2, 25±3 vs 18±2, 44±17 vs 32±9 mmHg, respectively). In the multivariate analysis, pre-operative LAVImin was the independent predictor of the post-operative symptomatic status after AVR (odds ratio: 1.11, 95% confidence interval: 1.04 - 1.18). Receiver operating characteristic analysis revealed that area under the curve (AUC) of LAVImin (cutoff: 30ml/m2) for post-operative symptoms was the largest (0.84) among the other echocardiographic parameters, and significantly larger than that of mean E/e' (0.67, *p<0.01) and LVEF (0.53, **p<0.05) (figure).
Figure 1. ROC analysis
Conclusions
The present results suggest that pre-operative echocardiographic LAVImin may be used as a surrogate for post-operative symptomatic status after AVR in patients with severe AS.
Collapse
|
17
|
P4349Simple and rapid estimation of left ventricular longitudinal deformation by tissue-tracking mitral annular displacement in single apical view. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz745.0757] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Noninvasive assessment of left ventricular (LV) deformation using global longitudinal strain (GLS) has prognostic value in patients with and without preserved ejection fraction (EF). Application of speckle-tracking technology to the mitral annulus provides rapid and easy assessment of displacement of septal and lateral mitral annulus and mid-point of mitral annular line in single apical view (TMAD) even in poor echo-image quality. TMAD may be used as a simple index of LV longitudinal deformation in patients with and without preserved EF (Figure).
Purpose
The purpose of this study was to examine whether TMAD can be used as a simple index of LV longitudinal deformation in patients with and without preserved EF.
Methods
The study population consists of 95 patients without segmental wall motion abnormality, significant valvular diseases, and atrial fibrillation in whom both TMAD and GLS measurements were applied by QLAB software (Philips). We estimated GLS from apical 4- and 2-chamber views and apical longitudinal views, and TMAD from apical 4-chamber view. TMAD was automatically and quickly evaluated as the base-to-apex displacement of septal (TMADsep), lateral (TMADlat), and mid-point of annular line (TMADmid) (Figure). The percentage of M-TMAD to LV length from the mid-point of mitral annuls to the apex at end-diastole (%TMADmid) was also calculated. We compared each TMAD values with GLS values by linear regression analysis, and evluated TMAD values by a receiver operating characteristic (ROC) analysis to detect impaired LV longitudinal deformation (|GLS|<12.0%).
Results
TMAD was successfully assessed in 94 of 95 patients (99%) while GLS was measured in 84 of 95 patients (87%, p=0.0082 vs TMAD). There were good correlations between each TMAD index and |GLS| (TMADsep:r=0.77, TMADlat:r=0.81, TMADmid:r=0.82, %TMADmid:r=0.87). According to ROC curve, the best cut-off values for TMADsep, TMADlat, TMADmid, and %TMADmid in determining LV longitudinal deformation were 6.8mm, 8.0mm, 7.8mm, and 9.5% respectively (Table).
Conclusions
The present results suggest that rapid and easy assessment of TMAD in single apical view may be used as a simple index of LV longitudinal deformation.
Collapse
|
18
|
|
19
|
|
20
|
P861Relationship between noninvasive assessment of left ventricular intra-ventricular pressure gradients estimated by vector flow mapping and left ventricular systolic and diastolic function. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy564.p861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
21
|
P784Association between cholesterol crystals piercing fibrous cap and plaque rupture in patients with acute coronary syndrome. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy564.p784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
22
|
P4667Value of speckle-tracking echocardiographic tricuspid annular displacement for the assessment of right ventricular systolic dysfunction. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy563.p4667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
23
|
A substantial step forward in the realization of the ITER HNB system: The ITER NBI Test Facility. FUSION ENGINEERING AND DESIGN 2017. [DOI: 10.1016/j.fusengdes.2016.11.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
24
|
Progress on design and manufacturing of dc ultra-high voltage component for ITER NBI. FUSION ENGINEERING AND DESIGN 2017. [DOI: 10.1016/j.fusengdes.2017.05.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
25
|
Development of long-pulse high-power-density negative ion beams with a multi-aperture multi-grid accelerator. FUSION ENGINEERING AND DESIGN 2017. [DOI: 10.1016/j.fusengdes.2017.01.060] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
26
|
Recent R&D Results on Fusion Nuclear Technology for ITER and DEMO Reactor in Japan. FUSION SCIENCE AND TECHNOLOGY 2017. [DOI: 10.1080/15361055.2017.1330625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
27
|
Beam Sweeping for Long-Pulse Operation of an Ion Source in Neutral Beam Injectors. FUSION SCIENCE AND TECHNOLOGY 2017. [DOI: 10.1080/15361055.2017.1319719] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
28
|
Schizophrenia-like phenotypes in mice with NMDA receptor ablation in intralaminar thalamic nucleus cells and gene therapy-based reversal in adults. Transl Psychiatry 2017; 7:e1047. [PMID: 28244984 PMCID: PMC5545645 DOI: 10.1038/tp.2017.19] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2016] [Accepted: 12/30/2016] [Indexed: 01/09/2023] Open
Abstract
In understanding the mechanism of schizophrenia pathogenesis, a significant finding is that drug abuse of phencyclidine or its analog ketamine causes symptoms similar to schizophrenia. Such drug effects are triggered even by administration at post-adolescent stages. Both drugs are N-methyl-d-aspartate receptor (NMDAR) antagonists, leading to a major hypothesis that glutamate hypofunction underlies schizophrenia pathogenesis. The precise region that depends on NMDAR function, however, is unclear. Here, we developed a mouse strain in which NMDARs in the intralaminar thalamic nuclei (ILN) were selectively disrupted. The mutant mice exhibited various schizophrenia-like phenotypes, including deficits in working memory, long-term spatial memory, and attention, as well as impulsivity, impaired prepulse inhibition, hyperlocomotion and hyperarousal. The electroencephalography analysis revealed that the mutant mice had a significantly reduced power in a wide range of frequencies including the alpha, beta and gamma bands, both during wake and rapid eye movement (REM) sleep, and a modest decrease of gamma power during non-REM sleep. Notably, restoring NMDARs in the adult ILN rescued some of the behavioral abnormalities. These findings suggest that NMDAR dysfunction in the ILN contributes to the pathophysiology of schizophrenia-related disorders. Furthermore, the reversal of inherent schizophrenia-like phenotypes in the adult mutant mice supports that ILN is a potential target site for a therapeutic strategy.
Collapse
|
29
|
Measurement of heat load density profile on acceleration grid in MeV-class negative ion accelerator. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02B137. [PMID: 26932019 DOI: 10.1063/1.4935636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
To understand the physics of the negative ion extraction/acceleration, the heat load density profile on the acceleration grid has been firstly measured in the ITER prototype accelerator where the negative ions are accelerated to 1 MeV with five acceleration stages. In order to clarify the profile, the peripheries around the apertures on the acceleration grid were separated into thermally insulated 34 blocks with thermocouples. The spatial resolution is as low as 3 mm and small enough to measure the tail of the beam profile with a beam diameter of ∼16 mm. It was found that there were two peaks of heat load density around the aperture. These two peaks were also clarified to be caused by the intercepted negative ions and secondary electrons from detailed investigation by changing the beam optics and gas density profile. This is the first experimental result, which is useful to understand the trajectories of these particles.
Collapse
|
30
|
Development of the negative ion beams relevant to ITER and JT-60SA at Japan Atomic Energy Agency. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02B322. [PMID: 26932050 DOI: 10.1063/1.4934584] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
In order to realize negative ion sources and accelerators to be applicable to International Thermonuclear Experimental Reactor and JT-60 Super Advanced, a large cesium (Cs)-seeded negative ion source and a multi-aperture and multi-stage electric acceleration have been developed at Japan Atomic Energy Agency (JAEA). Long pulse production and acceleration of the negative ion beams have been independently carried out. The long pulse production of the high current beams has achieved 100 s at the beam current of 15 A by modifying the JT-60 negative ion source. The pulse duration time is increased three times longer than that before the modification. As for the acceleration, a pulse duration time has been also extended two orders of magnitudes from 0.4 s to 60 s. The developments of the negative ion source and acceleration at JAEA are well in progress towards the realization of the negative ion sources and accelerators for fusion applications.
Collapse
|
31
|
Time evolution of negative ion profile in a large cesiated negative ion source applicable to fusion reactors. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02B144. [PMID: 26932026 DOI: 10.1063/1.4938406] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
To understand the physics of the cesium (Cs) recycling in the large Cs-seeded negative ion sources relevant to ITER and JT-60SA with ion extraction area of 45-60 cm × 110-120 cm, the time evolution of the negative ion profile was precisely measured in JT-60SA where the ion extraction area is longitudinally segmented into 5. The Cs was seeded from the oven at 180 °C to the ion source. After 1 g of Cs input, surface production of the negative ions appeared only in the central segment where a Cs nozzle was located. Up to 2 g of Cs, the negative ion profile was longitudinally expanded over full ion extraction area. The measured time evolution of the negative ion profile has the similar tendency of distribution of the Cs atoms that is calculated. From the results, it is suggested that Cs atom distribution is correlated with the formation of the negative ion profile.
Collapse
|
32
|
Development of design technique for vacuum insulation in large size multi-aperture multi-grid accelerator for nuclear fusion. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:02B304. [PMID: 26932032 DOI: 10.1063/1.4931803] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Design techniques for the vacuum insulation have been developed in order to realize a reliable voltage holding capability of multi-aperture multi-grid (MAMuG) accelerators for fusion application. In this method, the nested multi-stage configuration of the MAMuG accelerator can be uniquely designed to satisfy the target voltage within given boundary conditions. The evaluation of the voltage holding capabilities of each acceleration stages was based on the previous experimental results about the area effect and the multi-aperture effect. Since the multi-grid effect was found to be the extension of the area effect by the total facing area this time, the total voltage holding capability of the multi-stage can be estimated from that per single stage by assuming the stage with the highest electric field, the total facing area, and the total apertures. By applying these consideration, the analysis on the 3-stage MAMuG accelerator for JT-60SA agreed well with the past gap-scan experiments with an accuracy of less than 10% variation, which demonstrated the high reliability to design MAMuG accelerators and also multi-stage high voltage bushings.
Collapse
|
33
|
Demonstration of long-pulse acceleration of high power positive ion beam with JT-60 positive ion source in Japan–Korea joint experiment. FUSION ENGINEERING AND DESIGN 2016. [DOI: 10.1016/j.fusengdes.2015.11.033] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
34
|
Recent progress in R&D for long pulse and ultra-high voltage components for the ITER HNB. FUSION ENGINEERING AND DESIGN 2015. [DOI: 10.1016/j.fusengdes.2015.01.041] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
35
|
The effects of doxapram on medullary respiratory neurones in brainstem-spinal cord preparations from newborn rats. Anaesthesia 2014; 69:468-75. [DOI: 10.1111/anae.12590] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/11/2013] [Indexed: 11/26/2022]
|
36
|
Long-pulse beam acceleration of MeV-class H(-) ion beams for ITER NB accelerator. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02B304. [PMID: 24593581 DOI: 10.1063/1.4825161] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In order to realize neutral beam systems in International Thermonuclear Experimental Reactor whose target is to produce a 1 MeV, 200 A/m(2) during 3600 s D(-) ion beam, the electrostatic five-stages negative ion accelerator so-called "MeV accelerator" has been developed at Japan Atomic Energy Agency. To extend pulse length, heat load of the acceleration grids was reduced by controlling the ion beam trajectory. Namely, the beam deflection due to the residual magnetic field of filter magnet was suppressed with the newly developed extractor with a 0.5 mm off-set aperture displacement. The new extractor improved the deflection angle from 6 mrad to 1 mrad, resulting in the reduction of direct interception of negative ions from 23% to 15% of the total acceleration power, respectively. As a result, the pulse length of 130 A/m(2), 881 keV H(-) ion beam has been successfully extended from a previous value of 0.4 s to 8.7 s. This is the first long pulse negative ion beam acceleration over 100 MW/m(2).
Collapse
|
37
|
Development of negative ion extractor in the high-power and long-pulse negative ion source for fusion application. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02B320. [PMID: 24593597 DOI: 10.1063/1.4852297] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
High power and long-pulse negative ion extractor, which is composed of the plasma grid (PG) and the extraction grid (EXG), is newly developed toward the neutral beam injector for heating and current drive of future fusion machines such as ITER, JT-60 Super Advanced and DEMO reactor. The PG is designed to enhance surface production of negative ions efficiently by applying the chamfered aperture. The efficiency of the negative ion production for the discharge power increased by a factor of 1.3 against that of the conventional PG. The EXG is also designed with the thermal analysis to upgrade the cooling capability for the long pulse operation of >1000 s required in ITER. Though the magnetic field for electron suppression is reduced to 0.75 of that in the conventional EXG due to this upgrade, it was experimentally confirmed that the extracted electron current can be suppressed to the allowable level for the long pulse operation. These results show that newly developed extractor has the high potential for the long pulse extraction of the negative ions.
Collapse
|
38
|
Improvement of uniformity of the negative ion beams by tent-shaped magnetic field in the JT-60 negative ion source. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02B314. [PMID: 24593591 DOI: 10.1063/1.4830365] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Non-uniformity of the negative ion beams in the JT-60 negative ion source with the world-largest ion extraction area was improved by modifying the magnetic filter in the source from the plasma grid (PG) filter to a tent-shaped filter. The magnetic design via electron trajectory calculation showed that the tent-shaped filter was expected to suppress the localization of the primary electrons emitted from the filaments and created uniform plasma with positive ions and atoms of the parent particles for the negative ions. By modifying the magnetic filter to the tent-shaped filter, the uniformity defined as the deviation from the averaged beam intensity was reduced from 14% of the PG filter to ∼10% without a reduction of the negative ion production.
Collapse
|
39
|
Numerical analysis of atomic density distribution in arc driven negative ion sources. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02B125. [PMID: 24593565 DOI: 10.1063/1.4852296] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The purpose of this study is to calculate atomic (H(0)) density distribution in JAEA 10 ampere negative ion source. A collisional radiative model is developed for the calculation of the H(0) density distribution. The non-equilibrium feature of the electron energy distribution function (EEDF), which mainly determines the H(0) production rate, is included by substituting the EEDF calculated from 3D electron transport analysis. In this paper, the H(0) production rate, the ionization rate, and the density distribution in the source chamber are calculated. In the region where high energy electrons exist, the H(0) production and the ionization are enhanced. The calculated H(0) density distribution without the effect of the H(0) transport is relatively small in the upper region. In the next step, the effect should be taken into account to obtain more realistic H(0) distribution.
Collapse
|
40
|
100 s extraction of negative ion beams by using actively temperature-controlled plasma grid. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:02B312. [PMID: 24593589 DOI: 10.1063/1.4830216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Long pulse beam extraction with a current density of 120 A/m(2) for 100 s has been achieved with a newly developed plasma grid (PG) for the JT-60SA negative ion source which is designed to produce high power and long pulse beams with a negative ion current of 130 A/m(2) (22 A) and a pulse length of 100 s. The PG temperature is regulated by fluorinated fluids in order to keep the high PG temperature for the cesium-seeded negative ion production. The time constant for temperature controllability of the PG was measured to be below 10 s, which was mainly determined by the heat transfer coefficient of the fluorinated fluid. The measured decay time of the negative ion current extracted from the actively temperature-controlled PG was 430 s which was sufficient for the JT-60SA requirement, and much longer than that by inertial-cooling PG of 60 s. Obtained results of the long pulse capability are utilized to design the full size PG for the JT-60SA negative ion source.
Collapse
|
41
|
|
42
|
Commissioning of the first KSTAR neutral beam injection system and beam experiments. FUSION ENGINEERING AND DESIGN 2012. [DOI: 10.1016/j.fusengdes.2012.05.011] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
43
|
Beam optics in a MeV-class multi-aperture multi-grid accelerator for the ITER neutral beam injector. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:02B119. [PMID: 22380276 DOI: 10.1063/1.3673626] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
In a multi-aperture multi-grid accelerator of the ITER neutral beam injector, the beamlets are deflected due to space charge repulsion between beamlets and beam groups, and also due to magnetic field. Moreover, the beamlet deflection is influenced by electric field distortion generated by grid support structure. Such complicated beamlet deflections and the compensations have been examined utilizing a three-dimensional beam analysis. The space charge repulsion and the influence by the grid support structure were studied in a 1∕4 model of the accelerator including 320 beamlets. Beamlet deflection due to the magnetic field was studied by a single beamlet model. As the results, compensation methods of the beamlet deflection were designed, so as to utilize a metal bar (so-called field shaping plate) of 1 mm thick beneath the electron suppression grid (ESG), and an aperture offset of 1 mm in the ESG.
Collapse
|
44
|
Vacuum insulation of the high energy negative ion source for fusion application. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:02B117. [PMID: 22380274 DOI: 10.1063/1.3672471] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Vacuum insulation on a large size negative ion accelerator with multiple extraction apertures and acceleration grids for fusion application was experimentally examined and designed. In the experiment, vacuum insulation characteristics were investigated in the JT-60 negative ion source with >1000 apertures on the grid with the surface area of ∼2 m(2). The sustainable voltages varied with a square root of the gap lengths between the grids, and decreased with number of the apertures and with the surface area of the grids. Based on the obtained results, the JT-60SA (super advanced) negative ion source is designed to produce 22 A, 500 keV D(-) ion beams for 100 s.
Collapse
|
45
|
First neutral beam injection experiments on KSTAR tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:02B102. [PMID: 22380259 DOI: 10.1063/1.3660254] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The first neutral beam (NB) injection system of the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak was partially completed in 2010 with only 1∕3 of its full design capability, and NB heating experiments were carried out during the 2010 KSTAR operation campaign. The ion source is composed of a JAEA bucket plasma generator and a KAERI large multi-aperture accelerator assembly, which is designed to deliver a 1.5 MW, NB power of deuterium at 95 keV. Before the beam injection experiments, discharge, and beam extraction characteristics of the ion source were investigated. The ion source has good beam optics in a broad range of beam perveance. The optimum perveance is 1.1-1.3 μP, and the minimum beam divergence angle measured by the Doppler shift spectroscopy is 0.8°. The ion species ratio is D(+):D(2)(+):D(3)(+) = 75:20:5 at beam current density of 85 mA/cm(2). The arc efficiency is more than 1.0 A∕kW. In the 2010 KSTAR campaign, a deuterium NB power of 0.7-1.5 MW was successfully injected into the KSTAR plasma with a beam energy of 70-90 keV. L-H transitions were observed within a wide range of beam powers relative to a threshold value. The edge pedestal formation in the T(i) and T(e) profiles was verified through CES and electron cyclotron emission diagnostics. In every deuterium NB injection, a burst of D-D neutrons was recorded, and increases in the ion temperature and plasma stored energy were found.
Collapse
|
46
|
Voltage holding study of 1 MeV accelerator for ITER neutral beam injector. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:02B121. [PMID: 22380278 DOI: 10.1063/1.3675389] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Voltage holding test on MeV accelerator indicated that sustainable voltage was a half of that of ideal quasi-Rogowski electrode. It was suggested that the emission of the clumps is enhanced by a local electric field concentration, which leads to discharge initiation at lower voltage. To reduce the electric field concentration in the MeV accelerator, gaps between the grid supports were expanded and curvature radii at the support corners were increased. After the modifications, the accelerator succeeded in sustaining -1 MV in vacuum without beam acceleration. However, the beam energy was still limited at a level of 900 keV with a beam current density of 150 A∕m(2) (346 mA) where the 3 × 5 apertures were used. Measurement of the beam profile revealed that deflection of the H(-) ions was large and a part of the H(-) ions was intercepted at the acceleration grid. This causes high heat load on the grids and the breakdowns during beam acceleration. To suppress the direct interception, new grid system was designed with proper aperture displacement based on a 3D beam trajectory analysis. As the result, the beam deflection was compensated and the voltage holding during the beam acceleration was improved. Beam parameter of the MeV accelerator was increased to 980 keV, 185 A∕m(2) (427 mA), which is close to the requirement of ITER accelerator (1 MeV, 200 A∕m(2)).
Collapse
|
47
|
Effect of non-uniform electron energy distribution function on plasma production in large arc driven negative ion source. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:02A719. [PMID: 22380228 DOI: 10.1063/1.3673485] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Spatially non-uniform electron energy distribution function (EEDF) in an arc driven negative ion source (JAEA 10A negative ion source: 10 A NIS) is calculated numerically by a three-dimensional Monte Carlo kinetic model for electrons to understand spatial distribution of plasma production (such as atomic and ionic hydrogen (H(0)∕H(+)) production) in source chamber. The local EEDFs were directly calculated from electron orbits including electromagnetic effects and elastic∕inelastic collision forces. From the EEDF, spatial distributions of H(0)∕H(+) production rate were obtained. The results suggest that spatial non-uniformity of H(0)∕H(+) productions is enhanced by high energy component of EEDF.
Collapse
|
48
|
Slow Breathing and Emotions Associated with Odor-Induced Autobiographical Memories. Chem Senses 2012; 37:379-88. [DOI: 10.1093/chemse/bjr120] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
49
|
Development of a plasma generator for a long pulse ion source for neutral beam injectors. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2011; 82:063507. [PMID: 21721691 DOI: 10.1063/1.3599585] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
A plasma generator for a long pulse H(+)/D(+) ion source has been developed. The plasma generator was designed to produce 65 A H(+)/D(+) beams at an energy of 120 keV from an ion extraction area of 12 cm in width and 45 cm in length. Configuration of the plasma generator is a multi-cusp bucket type with SmCo permanent magnets. Dimension of a plasma chamber is 25 cm in width, 59 cm in length, and 32.5 cm in depth. The plasma generator was designed and fabricated at Japan Atomic Energy Agency. Source plasma generation and beam extraction tests for hydrogen coupling with an accelerator of the KSTAR ion source have been performed at the KSTAR neutral beam test stand under the agreement of Japan-Korea collaborative experiment. Spatial uniformity of the source plasma at the extraction region was measured using Langmuir probes and ±7% of the deviation from an averaged ion saturation current density was obtained. A long pulse test of the plasma generation up to 200 s with an arc discharge power of 70 kW has been successfully demonstrated. The arc discharge power satisfies the requirement of the beam production for the KSTAR NBI. A 70 keV, 41 A, 5 s hydrogen ion beam has been extracted with a high arc efficiency of 0.9 -1.1 A/kW at a beam extraction experiment. A deuteron yield of 77% was measured even at a low beam current density of 73 mA/cm(2).
Collapse
|
50
|
Population decline in the spoon-billed sandpiper (Eurynorhynchus pygmeus) in northern Chukotka based on monitoring on breeding grounds. BIOL BULL+ 2011. [DOI: 10.1134/s1062359010090074] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|