1
|
Transcatheter aortic valve implantation in patients with significant septal hypertrophy. Clin Res Cardiol 2024:10.1007/s00392-024-02432-3. [PMID: 38466346 DOI: 10.1007/s00392-024-02432-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Accepted: 02/29/2024] [Indexed: 03/13/2024]
Abstract
BACKGROUND Previous reports suggest septal hypertrophy with an interventricular septum depth (IVSD) ≥ 14 mm may adversely affect outcomes after transcatheter aortic valve implantation (TAVI) due to suboptimal valve placement, valve migration, or residual increased LVOT pressure gradients. AIMS This analysis investigates the impact of interventricular septal hypertrophy on acute outcomes after TAVI. METHODS Between 2009 and 2021, 1033 consecutive patients (55.8% male, 80.5 ± 6.7 years, EuroSCORE II 6.3 ± 6.5%) with documented IVSD underwent TAVI at our center and were included for analysis. Baseline, periprocedural, and 30-day outcome parameters of patients with normal IVSD (< 14 mm; group 1) and increased IVSD (≥ 14 mm; group 2) were compared. Data were retrospectively analyzed according to updated Valve Academic Research Consortium-3 (VARC-3) definitions. Comparison of outcome parameters was adjusted for baseline differences between groups using logistic and linear regression analyses. RESULTS Of 1033 patients, 585 and 448 patients were allocated to groups 1 and 2, respectively. There was no significant difference between groups regarding transfemoral access rate (82.6% (n = 478) vs. 86.0% (n = 381), p = 0.157). Postprocedural mean transvalvular pressure gradient was significantly increased in group 2 (group 1, 7.8 ± 4.1 mmHg, vs. group 2, 8.9 ± 4.9 mmHg, p = 0.046). Despite this finding, there was no significant difference between groups regarding the rates of VARC-3 adjudicated composite endpoint device success (90.0% (n = 522) vs. 87.6% (n = 388), p = 0.538) or technical success (92.6% (n = 542) vs. 92.6% (n = 415), p = 0.639). Moreover, the groups showed no significant differences regarding the rates of paravalvular leakage ≥ moderate (3.1% (n = 14) vs. 2.6% (n = 9), p = 0.993), postprocedural permanent pacemaker implantation (13.4% (n = 77) vs. 13.8% (n = 61), p = 0.778), or 30-day mortality (5.1% (n = 30) vs. 4.5% (n = 20), p = 0.758). CONCLUSION Although transvalvular mean pressure gradients were significantly higher in patients with increased IVSD after TAVI, acute outcomes were comparable between groups suggesting no early impact of adverse hemodynamics due to elevated IVSD. However, how these differences in hemodynamic findings may affect mid- and long-term outcomes, especially in terms of valve durability, needs to be evaluated in further investigations.
Collapse
|
2
|
Procedural success in transaxillary transcatheter aortic valve implantation according to type of transcatheter heart valve: results from the multicenter TAXI registry. Clin Res Cardiol 2024; 113:48-57. [PMID: 37138103 DOI: 10.1007/s00392-023-02216-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Accepted: 04/25/2023] [Indexed: 05/05/2023]
Abstract
BACKGROUND Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.
Collapse
|
3
|
Balloon-expandable transcatheter heart valves for treatment of aortic valve stenosis in patients with large aortic annuli: Evaluation of deployment balloon overfilling strategies. Catheter Cardiovasc Interv 2024; 103:194-201. [PMID: 38037296 DOI: 10.1002/ccd.30922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 11/02/2023] [Accepted: 11/19/2023] [Indexed: 12/02/2023]
Abstract
OBJECTIVES Transcatheter aortic valve implantation (TAVI) using balloon-expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients. METHODS Between January 2016 and December 2022, 45 patients (100% male, 76.9 ± 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-3 definitions. RESULTS Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (˂750 mm³) even in aortic annuli of 29.0-30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750-3200 mm³). Accordingly, a low calcification group (˂750 mm³, n = 17) compared to a significant calcification group (≥750 mm³, n = 28), presented with higher overfilling volumina (2.1 ± 1.4 vs. 0.8 ± 1.0; p ˂ 0.001), although aortic annulus diameter was not different (29.8 ± 0.8 vs. 29.9 ± 0.9 mm; p = 0.7). All-cause 30-day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 ± 3.6 mmHg. No case of PVL >mild was documented. CONCLUSION Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex ˂750 mm³.
Collapse
|
4
|
Valve-in-valve procedures for degenerated surgical and transcatheter aortic valve bioprostheses using a latest-generation self-expanding intra-annular transcatheter heart valve. Front Cardiovasc Med 2023; 10:1209184. [PMID: 37727306 PMCID: PMC10505706 DOI: 10.3389/fcvm.2023.1209184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 08/07/2023] [Indexed: 09/21/2023] Open
Abstract
Background Valve-in-valve (ViV) transfemoral transcatheter aortic valve implantation (TAVI) for failing aortic surgical bioprostheses or transcatheter heart valves (THV) has demonstrated a reasonable clinical and hemodynamic efficacy. Traditionally, self-expanding (SE) supra-annular THV are considered to result in superior hemodynamics compared with balloon-expandable intra-annular THV after ViV. However, so far no data are found on latest-generation intra-annular SE THV for aortic ViV procedures which might be superior with regard to coronary access or subsequent valve reintervention. Aim We herein aim to evaluate a latest-generation SE intra-annular THV for aortic ViV procedures. Materials and methods Between May 2022 and November 2022, five consecutive patients (4/5 female with mean age of 76.2 years and mean Society of Thoracic Surgeons predicted risk of mortality score of 2.9%) received ViV TAVI using the Navitor system (Abbott, Chicago, IL, USA) for treatment of failing surgical bioprostheses or THV. Data were retrospectively analyzed according to updated Valve Academic Research Consortium 3 (VARC-3) definitions. Results At 30 days, absence of mortality and VARC-3 adjudicated clinical endpoints were documented. Echocardiography at 30 days revealed complete absence of paravalvular leakage and single-digit mean transvalvular gradients (mean of 6.0 mmHg) in all patients. Conclusion The investigated intra-annular SE THV results in excellent 30-day outcomes for aortic ViV procedures for failing surgical bioprostheses or THV. Despite the intra-annular design, hemodynamic results were excellent, even in small bioprostheses. Ease of use of this valve platform is reflected by only two cycles of resheathing in five ViV procedures with hemodynamic stability during all steps of valve deployment.
Collapse
|
5
|
Outcomes of Transcatheter Aortic Valve Replacement in Patients With Severely Reduced Left Ventricular Systolic Function in the Low Systolic Function and Transcatheter Aortic Valve Implantation (LOSTAVI) International Registry. Am J Cardiol 2023; 201:349-358. [PMID: 37423004 DOI: 10.1016/j.amjcard.2023.06.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 05/30/2023] [Accepted: 06/05/2023] [Indexed: 07/11/2023]
Abstract
Transcatheter aortic valve replacement (TAVR) is an established therapy for severe, symptomatic aortic valve stenosis even in patients with impaired left ventricular systolic function. However, there is uncertainty on the clinical effectiveness of the currently available TAVR devices in patients with reduced left ventricular ejection fraction (LVEF). The LOSTAVI (Low Systolic function and Transcatheter Aortic Valve Implantation) registry is a retrospective observational study using baseline, procedural, discharge, and long-term follow-up details. A total of 3 groups of interest were distinguished: extremely reduced LVEF (<25%), severely reduced LVEF (25% to 30%), and reduced LVEF (31% to 35%). Unadjusted and adjusted analyses were carried out for in-hospital and follow-up outcomes. A total of 923 patients were included from 12 centers, with 146 patients (16%) with LVEF <25%, 425 (46%) with LVEF 25% to 30%, and 352 (38%) with LVEF 31% to 35%. Several baseline and procedural features were different across groups, including age, risk, functional class, and prevalence of bicuspid disease (all p <0.05). In-hospital mortality was similar in the 3 groups (7 [4.8%], 18 [4.2%], and 7 [2.0%], respectively, p = 0.661), but major adverse events were more common in those with extremely reduced and severely reduced LVEF (19 [13%], 53 [13%], and 25 [7.1%], respectively, p = 0.024). The 12-month follow-up confirmed the significant detrimental impact of reduced LVEF on both death (21 [14%], 49 [12%], and 25 [7.1%], respectively, p = 0.024) and major adverse events (37 [25%], 89 [21%], and 53 [15%], respectively, p = 0.016). The adjusted analysis confirmed the significant prognostic role of LVEF on both outcomes, whereas TAVR device type was not associated with death or major adverse events (all p >0.05). In conclusion, TAVR yields favorable early and 1-year results in patients with reduced LVEF, including those with extremely depressed systolic dysfunction. However, reduced LVEF still represents a major adverse prognostic factor for both short- and mid-term outcomes.
Collapse
|
6
|
Prognostic impact of implantable cardioverter defibrillators and associated adverse events in patients with continuous flow left ventricular assist devices. Front Cardiovasc Med 2023; 10:1158248. [PMID: 37332585 PMCID: PMC10272823 DOI: 10.3389/fcvm.2023.1158248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 05/15/2023] [Indexed: 06/20/2023] Open
Abstract
Objectives Implantation of implantable cardioverter defibrillators (ICD) reduces the risk of all-cause mortality in symptomatic heart failure (HF) patients with severe left ventricular (LV) dysfunction. Nevertheless, the prognostic impact of ICD therapy in continuous flow left ventricular assist device (LVAD) recipients remains controversial. Methods 162 consecutive HF patients, who underwent LVAD implantation at our institution between 2010 and 2019, were categorized according to the presence (n = 94, ICD-group) or absence (n = 68, Control-group) of ICDs. Apart from clinical baseline and follow-up parameters, adverse events (AEs) related to ICD therapy and overall survival rates were retrospectively analyzed. Results Out of 162 consecutive LVAD recipients 79 patients (48.8%) were preoperatively categorized as Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile ≤2. The prevalence of severe HF symptoms and preoperative use of short-term circulatory support devices (54.4% vs. 13.8%, p < 0.001) was higher within the Control-group, although baseline severity of LV and RV dysfunction was similar. Apart from an increased prevalence of perioperative right heart failure (RHF) within the Control-group (45.6% vs. 17.0%; p < 0.001), procedural characteristics and perioperative outcome were similar. Overall-survival during a median follow-up of 14 (3.0-36.5) months was similar within both groups (p = 0.46). During the first 2 years after LVAD implantation 53 ICD-related AEs occurred within the ICD-group. Thereof, lead-dysfunction occurred in 19 patients and unplanned ICD-reintervention in 11 patients. Furthermore, in 18 patients appropriate shocks without loss of consciousness occurred, whereas inappropriate shocks occurred in 5 patients. Conclusion ICD therapy in LVAD recipients was not associated with a survival benefit or reduced morbidity after LVAD implantation. Conservative ICD-programming seems to be justified to avoid ICD-related complications and "awake shocks" after LVAD implantation.
Collapse
|
7
|
Impact of Mitral Regurgitation Etiology on Mitral Surgery After Transcatheter Edge-to-Edge Repair: From the CUTTING-EDGE Registry. JACC Cardiovasc Interv 2023; 16:1176-1188. [PMID: 37225288 DOI: 10.1016/j.jcin.2023.02.029] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 01/30/2023] [Accepted: 02/21/2023] [Indexed: 05/26/2023]
Abstract
BACKGROUND Although >150,000 mitral TEER procedures have been performed worldwide, the impact of MR etiology on MV surgery after TEER remains unknown. OBJECTIVES The authors sought to compare outcomes of mitral valve (MV) surgery after failed transcatheter edge-to-edge repair (TEER) stratified by mitral regurgitation (MR) etiology. METHODS Data from the CUTTING-EDGE registry were retrospectively analyzed. Surgeries were stratified by MR etiology: primary (PMR) and secondary (SMR). MVARC (Mitral Valve Academic Research Consortium) outcomes at 30 days and 1 year were evaluated. Median follow-up was 9.1 months (IQR: 1.1-25.8 months) after surgery. RESULTS From July 2009 to July 2020, 330 patients underwent MV surgery after TEER, of which 47% had PMR and 53.0% had SMR. Mean age was 73.8 ± 10.1 years, median STS risk at initial TEER was 4.0% (IQR: 2.2%-7.3%). Compared with PMR, SMR had a higher EuroSCORE, more comorbidities, lower LVEF pre-TEER and presurgery (all P < 0.05). SMR patients had more aborted TEER (25.7% vs 16.3%; P = 0.043), more surgery for mitral stenosis after TEER (19.4% vs 9.0%; P = 0.008), and fewer MV repairs (4.0% vs 11.0%; P = 0.019). Thirty-day mortality was numerically higher in SMR (20.4% vs 12.7%; P = 0.072), with an observed-to-expected ratio of 3.6 (95% CI: 1.9-5.3) overall, 2.6 (95% CI: 1.2-4.0) in PMR, and 4.6 (95% CI: 2.6-6.6) in SMR. SMR had significantly higher 1-year mortality (38.3% vs 23.2%; P = 0.019). On Kaplan-Meier analysis, the actuarial estimates of cumulative survival were significantly lower in SMR at 1 and 3 years. CONCLUSIONS The risk of MV surgery after TEER is nontrivial, with higher mortality after surgery, especially in SMR patients. These findings provide valuable data for further research to improve these outcomes.
Collapse
|
8
|
Prognostic impact and diagnostic value of invasively derived hemodynamic measures in patients with severe aortic stenosis undergoing TAVI. Clin Res Cardiol 2023; 112:667-676. [PMID: 36656376 PMCID: PMC10160203 DOI: 10.1007/s00392-023-02154-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Accepted: 01/05/2023] [Indexed: 01/20/2023]
Abstract
BACKGROUND Ejection time (ET), acceleration time (AT) and time between left ventricular and aortic systolic pressure peaks (T-LVAo) might be of diagnostic and prognostic use in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). AIM We aimed to assess the diagnostic value and prognostic impact of invasively measured ET, AT, and T-LVAo in patients undergoing TAVI. METHODS A total of 1274 patients received invasive measurement of ET, AT and T-LVAo prior to TAVI. Anatomic AS severity was assessed by CT-derived aortic valve calcification density (AVCd). Impact on all-cause mortality was retrospectively analyzed. RESULTS In multivariable linear regression, T-LVAo showed the strongest correlation with AVCd. No prognostic impact of T-LVAo was found according to uni- and multivariable analyses. In contrast, using an individual C-statistic derived cutoff (CD), patients with ET or AT ≥ CD showed lower mortality rates compared to patients with ET or AT < CD (1-year mortality: ET ≥ vs. < CD: 15.01vs. 33.1%, AT ≥ vs < CD 16.3 vs. 26.5%, p < 0.001). Moreover, multivariable analysis identified ET ≥ CD (HR 0.61 [95% CI 0.43-0.87; p < 0.007]) to be associated with beneficial outcome after TAVI, independent from clinical risk factors and echocardiography-derived parameters. CONCLUSION Among the studied hemodynamic parameters T-LVAo provides the highest diagnostic value, whereas ET is an outcome predictor beyond clinical risk factors and echocardiographic parameters in AS patients following TAVI. These parameters could be of considerable use in diagnostic evaluation and risk assessment of patients scheduled for TAVI. T-LVAo (yellow): defined as time between left ventricular and aortic systolic pressure peaks. ET (green): Ejection Time defined as time from the start to flow end. AT (orange): Acceleration time defined as time from the start to the peak flow. AOP: aortic pressure, AVC: aortic valve calcification, CI: confidence interval, HGAS: high-gradient aortic stenosis, LGAS: low-gradient aortic stenosis, LVP: left ventricular pressure, SD: standard deviation.
Collapse
|
9
|
Preliminary Experience of Extracorporeal Cytokine Hemoadsorption during Left Ventricular Assist Device Implantation in Cardiogenic Shock Patients. Thorac Cardiovasc Surg 2022. [PMID: 36216331 DOI: 10.1055/s-0042-1757300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
BACKGROUND Systemic inflammation due to cardiogenic shock is associated with vasoplegia leading to organ hypoperfusion, right heart failure, and poor clinical outcome. Extracorporeal cytokine hemoadsorption emerged to attenuate excessive levels of inflammatory cytokines, potentially improving patient outcomes. Nevertheless, its prognostic impact during high-risk left ventricular assist device (LVAD) implantation remains unknown. METHODS In total, 40 consecutive patients with advanced heart failure underwent continuous-flow LVAD implantation at our institution between 2018 and 2020. Out of 25 high-risk patients in cardiogenic shock (Interagency Registry for Mechanically Assisted Circulatory Support profile 1 and 2), 9 patients (CytoSorb group) underwent LVAD implantation with and 16 patients (control group) without simultaneous cytokine hemoadsorption during cardiopulmonary bypass. Besides preoperative patient characteristics, postoperative lactate clearance, vasopressor administration and mean arterial pressure, perioperative complication, and 30-day mortality rates were retrospectively analyzed. RESULTS Apart from an increased rate of reoperations within the CytoSorb group, baseline characteristics including the severity of ventricular dysfunction and consecutive signs of end-organ failure were similar in both groups. Preoperative short-term mechanical circulatory support bridging was comparable (66.7 vs. 75%; p = 0.66) prior to LVAD implantation. Procedural characteristics including intraoperative volume management and postoperative vasopressor administration were similar in both groups. There was no difference regarding postoperative lactate clearance, although postoperative mean arterial pressure was significantly higher in the control group (71.3 vs. 57.4 mm Hg; p < 0.01). Furthermore, the 30-day mortality rate was significantly higher in the CytoSorb group (33.3 vs. 0.0%; p = 0.01). CONCLUSION Extracorporeal cytokine hemoadsorption during high-risk LVAD implantation was not associated with a decrease of postoperative vasopressor support, improved hemodynamics, or an accelerated lactate clearance.
Collapse
|
10
|
Early Outcomes of Endoscopic Papillary Muscle Relocation for Secondary Mitral Regurgitation Type IIIb in Patients With Severe Left Ventricular Dysfunction. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2022; 17:317-323. [PMID: 35983699 PMCID: PMC9403379 DOI: 10.1177/15569845221115419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Objective: Subannular mitral valve (MV) repair techniques have been
developed to address increased rates of recurrent mitral regurgitation (MR) in
patients with secondary MR (SMR) type IIIb. Endoscopic papillary muscle
relocation (PMR) is feasible via minithoracotomy. Nevertheless, the
periprocedural outcome of patients with severe left ventricular (LV) dysfunction
remains unknown. Methods: A total of 98 consecutive patients with
SMR type IIIb underwent PMR at our institution. Due to concomitant coronary
artery bypass grafting, 62 patients underwent sternotomy and were excluded from
the current analysis, whereas 36 patients were treated by a minimally invasive
technique using 3-dimensional endoscopy. Of these, 18 patients had severely
depressed LV ejection fraction (LVEF) ≤35% (study group) and were compared to
the remaining 18 patients with LVEF >35% (control group). Periprocedural
outcome was retrospectively analyzed. Results: Although LVEF was
significantly worse in the study group (30% ± 4% vs 43% ± 6%,
P < 0.001), the severity of SMR and the degree of MV leaflet
tethering were similar. The prevalence of concomitant procedures and the
duration of surgery, cardiopulmonary bypass, and aortic cross-clamp were
comparable. Periprocedural low cardiac output syndrome was favorably low in both
groups (16.7% vs 5.6%, P = 0.29). Postoperative ventilation
time (5.7 h [4.2 to 8.7 h] vs 6.0 h [4.6 to 9.8 h], P = 0.43)
and duration of intensive care unit stay (2 days [1 to 3 days] vs 2 days [1 to 3
days], P = 0.22) were similar. There was no 30-day mortality in
either group. Conclusions: Standardized endoscopic PMR resulted in
favorable periprocedural outcomes in patients with severe LV dysfunction,
suggesting that minimally invasive surgery can safely be extended to this
patient population.
Collapse
|
11
|
Percutaneous vs surgical axillary access for transcatheter aortic valve implantation: the TAXI registry. Panminerva Med 2022; 64:427-437. [PMID: 35638242 DOI: 10.23736/s0031-0808.22.04750-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Transcatheter aortic valve implantation (TAVI) is an established management strategy for severe aortic valve stenosis. Percutaneous axillary approach for TAVI holds the promise of improving safety without jeopardizing effectiveness in comparison to surgical access. We aimed at appraising the comparative effectiveness of percutaneous vs surgical axillary approaches for TAVI. METHODS We performed an international retrospective observational study using de-identified details on baseline, procedural, and 1-month follow-up features. Valve Academic Research Consortium (VARC)-3 criteria were applied throughout. Outcomes of interest were clinical events up to 1 month of follow-up, compared with unadjusted and propensity score-adjusted analyses. RESULTS A total of 432 patients were included, 189 (43.8%) receiving surgical access, and 243 (56.2%) undergoing percutaneous access. Primary hemostasis failure was more common in the percutaneous group (13.2% vs 4.2%, p<0.001), leading to more common use of covered stent implantation (13.2% vs 3.7%, p<0.001). Irrespectively, percutaneous access was associated with shorter hospital stay (-2.6 days [95% confidence interval: -5.0; -0.1], p=0.038), a lower risk of major adverse events (a composite of death, myocardial infarction, stroke, type 3 bleeding, and major access-site related complication; odds ratio=0.44 [0.21; 0.95], p=0.036), major access-site non-vascular complications (odds ratio=0.21 [0.06; 0.77], p=0.018), and brachial plexus impairment (odds ratio=0.16 [0.03; 0.76], p=0.021), and shorter hospital stay (-2.6 days [-5.0; -0.1], p=0.038). CONCLUSIONS Percutaneous axillary access provides similar or better results than surgical access in patients undergoing TAVI with absolute or relative contraindications to femoral access.
Collapse
|
12
|
Standardized papillary muscle relocation for type IIIb secondary mitral regurgitation improves two-year outcome. Eur J Cardiothorac Surg 2022; 62:6576629. [PMID: 35511127 DOI: 10.1093/ejcts/ezac285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 04/06/2022] [Accepted: 04/27/2022] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES The major drawback of isolated annuloplasty for treatment of secondary mitral regurgitation (SMR) with restricted leaflet motion during systole (type IIIb) is recurrence of SMR, leading to adverse clinical outcome. Additional papillary muscles relocation (PMR) specifically addresses leaflet tethering to restore mitral valve geometry. We aimed to compare the two-year outcome of annuloplasty with additional PMR vs isolated annuloplasty. METHODS A total of 105 consecutive type IIIb SMR patients with preoperative LVEF <45%, LVEDD >55mm and a tenting height >10mm, reached two-year postoperative follow-up after MV repair and were included in the current analysis. 51 patients underwent annuloplasty and additional PMR (study group). 54 patients underwent isolated annuloplasty (control group). Primary composite study end-point comprised death or recurrence of MR ≥2 at two years postoperatively. RESULTS Echocardiographic baseline variables indicating the severity of left ventricular (LV) dysfunction and mitral leaflet tethering were similar. Procedural and periprocedural outcome was comparable in both groups. The primary composite end-point was significantly improved in the study group 19.6% [10/51] in comparison to the control group 44.4% [24/54] (p = 0.009). 2-year all-cause mortality was 7.8% [4/51] in the study group, vs 18.5% [10/54] in the control group (p = 0.098). After two years, significant improvement of NYHA functional class as compared to the baseline values was observed in the study group. CONCLUSIONS Additional PMR to treat SMR type IIIb resulted in an improved 2-year outcome in comparison to isolated annuloplasty. PMR specifically addressing mitral leaflet tethering represents a valid therapeutic option for heart-failure patients with SMR type IIIb.
Collapse
|
13
|
TAVI for Pure Non-calcified Aortic Regurgitation Using a Self-Expandable Transcatheter Heart Valve. Front Cardiovasc Med 2022; 8:743579. [PMID: 35146003 PMCID: PMC8823702 DOI: 10.3389/fcvm.2021.743579] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Accepted: 12/08/2021] [Indexed: 11/13/2022] Open
Abstract
Objectives: Transcatheter aortic valve implantation (TAVI) is routinely performed in patients with severe aortic stenosis (AS). For patients with pure non-calcified aortic regurgitation (AR) who are not suitable for open heart surgery no clear recommendations exist and use of TAVI has been largely off-label. We herein report a series of patients treated with the self-expandable AcurateNeo and Neo2 (Boston Scientific Co., Marlborough, MS, USA) transcatheter heart valve (THV) for pure AR.Methods: Between 05/2017 and 03/2021, 9 patients (88.8% female, 74.4 ± 7.1 years, logEuroSCORE II 5.5 ± 3.6%, STS PROM 6.2 ± 3.0%) received transfemoral (TF) TAVI for pure non-calcified AR following an adjusted valve sizing algorithm. Data were retrospectively analyzed according to updated Valve Academic Research Consortium (VARC-2) definitions.Results: Device success was 100%. Early safety was 77.7% (7/10), due to two (22.2%) cases of acute kidney injury. Thirty-day mortality was 0%, in seven (77.7%) patients no or trace paravalvular leakage (PVL) was seen and mild PVL in two (22.2%) patients at 30-day follow-up. No permanent pacemaker (PPM) was required during 30-day follow-up.Conclusion: In this series of selected patients using the Acurate neo THV for pure non-calcified AR, safety and efficacy were demonstrated. Thirty-day mortality as well as PPM implantation and PVL rates showed excellent results in this high-risk patient cohort. These results will have to be confirmed in larger patient cohorts.
Collapse
|
14
|
Prevention of coronary obstruction in patients at risk undergoing transcatheter aortic valve implantation: the Hamburg BASILICA experience. Clin Res Cardiol 2021; 110:1900-1911. [PMID: 34156524 PMCID: PMC8639537 DOI: 10.1007/s00392-021-01881-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Accepted: 05/26/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVES This study aimed to assess the clinical outcome of the bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary obstruction (BASILICA) technique in a single-center patient cohort considered at high or prohibitive risk of transcatheter aortic valve implantation (TAVI)-induced coronary obstruction. METHODS Between October 2019 and January 2021, a total of 15 consecutive patients (age 81.0 [78.1, 84.4] years; 53.3% female; EuroSCORE II 10.6 [6.3, 14.8] %) underwent BASILICA procedure prior to TAVI at our institution. Indications for TAVI were degeneration of stented (n = 12, 80.0%) or stentless (n = 1, 6.7%) bioprosthetic aortic valves, or calcific stenosis of native aortic valves (n = 2, 13.3%), respectively. Individual risk of TAVI-induced coronary obstruction was assessed by pre-procedural computed tomography analysis. Procedural and 30-day outcomes were documented in accordance with Valve Academic Research Consortium (VARC)-2 criteria. RESULTS BASILICA was attempted for single left coronary cusp in 12 patients (80.0%), for single right coronary cusp in 2 patients (13.3%), and for both cusps in 1 patient (6.7%), respectively. The procedure was feasible in 13 patients (86.7%) resulting in effective prevention of coronary obstruction, whilst TAVI was performed without prior successful bioprosthetic leaflet laceration in two patients (13.3%). In one of these patients (6.7%), additional chimney stenting immediately after TAVI was performed. No all-cause deaths or strokes were documented after 30 days. CONCLUSION The BASILICA technique appears to be a feasible, safe and effective concept to avoid iatrogenic coronary artery obstruction during TAVI in both native and bioprosthetic valves of patients at high or prohibitive risk. ClinicalTrials.gov Identifier: NCT04227002 (Hamburg AoRtic Valve cOhoRt).
Collapse
|
15
|
Bioprosthetic valve fracture: Predictors of outcome and follow-up. Results from a multicenter study. Catheter Cardiovasc Interv 2021; 98:756-764. [PMID: 33991385 DOI: 10.1002/ccd.29755] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 03/21/2021] [Accepted: 05/03/2021] [Indexed: 11/11/2022]
Abstract
OBJECTIVES To evaluate outcome and its predictors of bioprosthetic valve fracture (BVF) in patients undergoing valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). BACKGROUND BVF is feasible and reduces transvalvular gradients in VIV-TAVR-procedures, but follow-up-data and information on factors influencing the outcome are missing. METHODS The 81 cases of BVF-VIV-TAVR were collected from 14 international centers. RESULTS Predominantly transcatheter heart valve (THV) was implanted first, followed by BVF. VARC-2 defined device success was 93%, most failures were attributed to residual high gradients. Mean gradients decreased from 37 ± 13 mmHg to 10.8 ± 5.9 mmHg (p < 0.001). BVF reduced the gradient by 16 mmHg. During follow-up (FU, 281 ± 164 days) mean gradient remained stable (10.8 ± 5.9 mmHg at discharge, 12.4 ± 6.3 mmHg at FU, p = ns). In-hospital major adverse events occurred in 3.7%. Event-free survival at 276 ± 237.6 days was 95.4%. The linear mixed model identified balloon-expandable valves (BEV), Mitroflow surgical valve, stenotic surgical bioprostheses and balloon only 1 mm larger than the true internal diameter of the surgical valve as predictors for higher gradients. CONCLUSIONS BVF is safe and can significantly reduce gradients, which remain stable at FU. BEV, Mitroflow surgical valve, stenotic bioprostheses and balloon larger than the true internal diameter of the surgical valve of only 1 mm are predictors for higher final gradients.
Collapse
|
16
|
Transaxillary transcatheter ACURATE neo aortic valve implantation - The TRANSAX multicenter study. Catheter Cardiovasc Interv 2020; 98:E291-E298. [PMID: 33315296 DOI: 10.1002/ccd.29423] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Revised: 10/25/2020] [Accepted: 11/29/2020] [Indexed: 11/09/2022]
Abstract
BACKGROUND Transcatheter aortic valve replacement (TAVR) via transaxillary (TAx) approach with ACURATE neo valve is an off-label procedure. Our aim was to gather information on ACURATE neo cases implanted via TAx approach and report major outcomes. METHODS AND RESULTS The TRANSAX Study (NCT04274751) retrospectively gathered patients from nine centres in Europe and North America treated with ACURATE neo valve through TAx approach up to May/2019. Follow up was pre-specified at 1-year and was obtained for all patients. A total of 75 patients (79 ± 10 years; 32% women) were included. Left axillary (72%) and conscious sedation (95.2%) were the most common setting. Risk scores were higher when right axillary artery and surgical cut-down were selected. Severe complications including valve embolization, coronary obstruction, annulus rupture, and procedural mortality did not occur. Cardiac tamponade occurred in two cases (2.7%) with one requiring conversion to open surgery (1.3%). Bail-out stenting and surgical vascular repair were required in 7 (9.3%) and 3 (4%) cases, respectively. The need for new permanent pacemaker was 8%. Procedural success (96%), in-hospital (2.7%), and 1-year mortality (8%) were comparable in all settings. Only one case (1.3%) complicated with cerebrovascular event and one (1.3%) presented moderate aortic regurgitation before discharge. CONCLUSIONS TAx TAVR procedures with the ACURATE neo valve were presented high success rate and low in-hospital and 1-year mortality.
Collapse
|
17
|
Prognostic value of the H 2 FPEF score in patients undergoing transcatheter aortic valve implantation. ESC Heart Fail 2020; 8:461-470. [PMID: 33215870 PMCID: PMC7835574 DOI: 10.1002/ehf2.13096] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 10/02/2020] [Accepted: 10/22/2020] [Indexed: 02/06/2023] Open
Abstract
Aims The aim of this study was to assess the prognostic value of the H2FPEF score in patients undergoing transcatheter aortic valve implantation (TAVI) for severe aortic stenosis (AS) and preserved left ventricular ejection fraction (EF). Methods and results In this multicentre study, a total of 832 patients from two German high‐volume centres, who received TAVI for severe AS and preserved EF (≥50%), were identified for calculation of the H2FPEF score. Patients were dichotomized according to low (0–5 points; n = 570) and high (6–9 points; n = 262) H2FPEF scores. Kaplan–Meier and Cox regression analyses were applied to assess the prognostic impact of the H2FPEF score. We observed a decrease in stroke volume index (−2.04 mL/m2/point) and mean transvalvular gradients (−1.14 mmHg/point) with increasing H2FPEF score translating into a higher prevalence of paradoxical low‐flow, low‐gradient AS among patients with high H2FPEF score. One year after TAVI, the rates of all‐cause (low vs. high H2FPEF score: 8.0% vs. 19.4%, P < 0.0001) and cardiovascular (CV) mortality (1.9% vs. 9.0%, P < 0.0001) as well as the rate of CV mortality or rehospitalization for congestive heart failure (6.4% vs. 23.2%, P < 0.0001) were higher in patients with high H2FPEF score compared with those with low H2FPEF score. After multivariable analysis, a high H2FPEF score remained independently predictive of all‐cause mortality [hazard ratio 1.59 (1.28–2.35), P = 0.018] and CV mortality or rehospitalization for congestive heart failure [hazard ratio 2.92 (1.65–5.15), P < 0.001]. Among the H2FPEF score variables, atrial fibrillation, pulmonary hypertension, and elevated left ventricular filling pressure were the strongest outcome predictors. Conclusions The H2FPEF score serves as an independent predictor of adverse CV and heart failure outcome among TAVI patients with preserved EF. A high H2FPEF score is associated with the presence of paradoxical low‐flow, low‐gradient AS, the HFpEF in patients with AS. By identifying patients in advanced stages of HFpEF, the H2FPEF score might be useful as a risk prediction tool in patients with preserved EF scheduled for TAVI.
Collapse
|
18
|
TAVR for low-flow, low-gradient aortic stenosis: Prognostic impact of aortic valve calcification. Am Heart J 2020; 225:138-148. [PMID: 32502877 DOI: 10.1016/j.ahj.2020.03.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2020] [Accepted: 03/16/2020] [Indexed: 10/24/2022]
Abstract
BACKGROUND Compared to high gradient aortic stenosis (AS), patients with low-flow, low-gradient AS have higher mortality after transcatheter aortic valve replacement (TAVR), but distinct outcome predictors in this patient subset are yet to be determined. The present study investigated the prognostic impact of aortic valve calcification (AVC) in patients with low-flow, low-gradient AS undergoing TAVR. METHODS This retrospective single-center analysis includes all patients undergoing TAVR for severe low-flow, low-gradient AS (n = 526), ie, low EF low gradient AS (LEF-LG AS; n = 290) and paradoxical low-flow, low-gradient AS (PLF-LG AS; n = 236), in whom AVC was quantified from contrast-enhanced multislice computed tomography images. AVCdensity was defined as calcium volume per annulus area. Patients were trichotomized according to sex-specific AVCdensity tertiles in both subgroups. All-cause mortality was assessed by Kaplan-Meier analyses and independent outcome predictors were determined by multivariable analyses. RESULTS In both subgroups, patients with high AVCdensity had higher mean transvalvular gradients at baseline and higher rates of PVL after TAVR. High AVCdensity was associated with lowest 1- and 3-year mortality after TAVR in the LEF-LG AS but not in the PLF-LG AS group. According to multivariable analysis AVCdensity was independently associated with better survival in LEF-LG AS patients (HR 0.73 [0.60-0.88], P = .0011), but not in those with PLF-LG AS (HR 0.91 [0.73-1.14], P = .42). CONCLUSIONS Quantification of AVC may not only be of diagnostic but also of prognostic value, as it facilitates the selection of LEF-LG AS patients with higher probability of beneficial outcome after TAVR.
Collapse
|
19
|
Transcatheter Aortic Valve Replacement With Next-Generation Self-Expanding Devices. JACC Cardiovasc Interv 2019; 12:433-443. [DOI: 10.1016/j.jcin.2018.11.036] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Revised: 11/08/2018] [Accepted: 11/26/2018] [Indexed: 10/27/2022]
|
20
|
Hepatitis delta virus persists during liver regeneration and is amplified through cell division both in vitro and in vivo. Gut 2019; 68:150-157. [PMID: 29217749 DOI: 10.1136/gutjnl-2017-314713] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2017] [Revised: 11/17/2017] [Accepted: 11/20/2017] [Indexed: 12/18/2022]
Abstract
OBJECTIVE Hepatitis delta virus (HDV) was shown to persist for weeks in the absence of HBV and for months after liver transplantation, demonstrating the ability of HDV to persevere in quiescent hepatocytes. The aim of the study was to evaluate the impact of cell proliferation on HDV persistence in vitro and in vivo. DESIGN Genetically labelled human sodium taurocholate cotransporting polypeptide (hNTCP)-transduced human hepatoma(HepG2) cells were infected with HBV/HDV and passaged every 7 days for 100 days in the presence of the entry inhibitor Myrcludex-B. In vivo, cell proliferation was triggered by transplanting primary human hepatocytes (PHHs) isolated from HBV/HDV-infected humanised mice into naïve recipients. Virological parameters were measured by quantitative real time polymerase chain reaction (qRT-PCR). Hepatitis delta antigen (HDAg), hepatitis B core antigen (HBcAg) and cell proliferation were determined by immunofluorescence. RESULTS Despite 15 in vitro cell passages and block of viral spreading by Myrcludex-B, clonal cell expansion permitted amplification of HDV infection. In vivo, expansion of PHHs isolated from HBV/HDV-infected humanised mice was confirmed 3 days, 2, 4 and 8 weeks after transplantation. While HBV markers rapidly dropped in proliferating PHHs, HDAg-positive hepatocytes were observed among dividing cells at all time points. Notably, HDAg-positive cells appeared in clusters, indicating that HDV was transmitted to daughter cells during liver regeneration even in the absence of de novo infection. CONCLUSION This study demonstrates that HDV persists during liver regeneration by transmitting HDV RNA to dividing cells even in the absence of HBV coinfection. The strong persistence capacities of HDV may also explain why HDV clearance is difficult to achieve in HBV/HDV chronically infected patients.
Collapse
|
21
|
Binding of hepatitis B virus to its cellular receptor alters the expression profile of genes of bile acid metabolism. Hepatology 2014; 60:1483-93. [PMID: 24711282 DOI: 10.1002/hep.27159] [Citation(s) in RCA: 106] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2013] [Accepted: 04/02/2014] [Indexed: 12/20/2022]
Abstract
UNLABELLED Chronic hepatitis B virus (HBV) infection has been associated with alterations in lipid metabolism. Moreover, the Na+-taurocholate cotransporting polypeptide (NTCP), responsible for bile acid (BA) uptake into hepatocytes, was identified as the functional cellular receptor mediating HBV entry. The aim of the study was to determine whether HBV alters the liver metabolic profile by employing HBV-infected and uninfected human liver chimeric mice. Humanized urokinase plasminogen activator/severe combined immunodeficiency mice were used to establish chronic HBV infection. Gene expression profiles were determined by real-time polymerase chain reaction using primers specifically recognizing transcripts of either human or murine origin. Liver biopsy samples obtained from HBV-chronic individuals were used to validate changes determined in mice. Besides modest changes in lipid metabolism, HBV-infected mice displayed a significant enhancement of human cholesterol 7α-hydroxylase (human [h]CYP7A1; median 12-fold induction; P<0.0001), the rate-limiting enzyme promoting the conversion of cholesterol to BAs, and of genes involved in transcriptional regulation, biosynthesis, and uptake of cholesterol (human sterol-regulatory element-binding protein 2, human 3-hydroxy-3-methylglutaryl-coenzyme A reductase, and human low-density lipoprotein receptor), compared to uninfected controls. Significant hCYP7A1 induction and reduction of human small heterodimer partner, the corepressor of hCYP7A1 transcription, was also confirmed in liver biopsies from HBV-infected patients. Notably, administration of Myrcludex-B, an entry inhibitor derived from the pre-S1 domain of the HBV envelope, provoked a comparable murine CYP7A1 induction in uninfected mice, thus designating the pre-S1 domain as the viral component triggering such metabolic alterations. CONCLUSION Binding of HBV to NTCP limits its function, thus promoting compensatory BA synthesis and cholesterol provision. The intimate link determined between HBV and liver metabolism underlines the importance to exploit further metabolic pathways, as well as possible NTCP-related viral-drug interactions.
Collapse
|