1
|
Reliability of pediatric ventricular function analysis by short-axis "single-cycle-stack-advance" single-shot compressed-sensing cines in minimal breath-hold time. Eur Radiol 2021; 32:2581-2593. [PMID: 34713331 PMCID: PMC8921124 DOI: 10.1007/s00330-021-08335-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 07/09/2021] [Accepted: 07/23/2021] [Indexed: 12/28/2022]
Abstract
Objectives Cardiovascular magnetic resonance (CMR) cine imaging by compressed sensing (CS) is promising for patients unable to tolerate long breath-holding. However, the need for a steady-state free-precession (SSFP) preparation cardiac cycle for each slice extends the breath-hold duration (e.g. for 10 slices, 20 cardiac cycles) to an impractical length. We investigated a method reducing breath-hold duration by half and assessed its reliability for biventricular volume analysis in a pediatric population. Methods Fifty-five consecutive pediatric patients (median age 12 years, range 7–17) referred for assessment of congenital heart disease or cardiomyopathy were included. Conventional multiple breath-hold SSFP short-axis (SAX) stack cines served as the reference. Real-time CS SSFP cines were applied without the steady-state preparation cycle preceding each SAX cine slice, accepting the limitation of omitting late diastole. The total acquisition time was 1 RR interval/slice. Volumetric analysis was performed for conventional and “single-cycle-stack-advance” (SCSA) cine stacks. Results Bland–Altman analyses [bias (limits of agreement)] showed good agreement in left ventricular (LV) end-diastolic volume (EDV) [3.6 mL (− 5.8, 12.9)], LV end-systolic volume (ESV) [1.3 mL (− 6.0, 8.6)], LV ejection fraction (EF) [0.1% (− 4.9, 5.1)], right ventricular (RV) EDV [3.5 mL (− 3.34, 10.0)], RV ESV [− 0.23 mL (− 7.4, 6.9)], and RV EF [1.70%, (− 3.7, 7.1)] with a trend toward underestimating LV and RV EDVs with the SCSA method. Image quality was comparable for both methods (p = 0.37). Conclusions LV and RV volumetric parameters agreed well between the SCSA and the conventional sequences. The SCSA method halves the breath-hold duration of the commercially available CS sequence and is a reliable alternative for volumetric analysis in a pediatric population. Key Points • Compressed sensing is a promising accelerated cardiovascular magnetic resonance imaging technique. • We omitted the steady-state preparation cardiac cycle preceding each cine slice in compressed sensing and achieved an acquisition speed of 1 RR interval/slice. • This modification called “single-cycle-stack-advance” enabled the acquisition of an entire short-axis cine stack in a single short breath hold. • When tested in a pediatric patient group, the left and right ventricular volumetric parameters agreed well between the “single-cycle-stack-advance” and the conventional sequences.
Collapse
|
2
|
Motion-corrected multiparametric renal arterial spin labelling at 3 T: reproducibility and effect of vasodilator challenge. Eur Radiol 2018; 29:232-240. [PMID: 29992384 PMCID: PMC6291439 DOI: 10.1007/s00330-018-5628-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Revised: 06/14/2018] [Accepted: 06/22/2018] [Indexed: 02/02/2023]
Abstract
OBJECTIVES We investigated the feasibility and reproducibility of free-breathing motion-corrected multiple inversion time (multi-TI) pulsed renal arterial spin labelling (PASL), with general kinetic model parametric mapping, to simultaneously quantify renal perfusion (RBF), bolus arrival time (BAT) and tissue T1. METHODS In a study approved by the Health Research Authority, 12 healthy volunteers (mean age, 27.6 ± 18.5 years; 5 male) gave informed consent for renal imaging at 3 T using multi-TI ASL and conventional single-TI ASL. Glyceryl trinitrate (GTN) was used as a vasodilator challenge in six subjects. Flow-sensitive alternating inversion recovery (FAIR) preparation was used with background suppression and 3D-GRASE (gradient and spin echo) read-out, and images were motion-corrected. Parametric maps of RBF, BAT and T1 were derived for both kidneys. Agreement was assessed using Pearson correlation and Bland-Altman plots. RESULTS Inter-study correlation of whole-kidney RBF was good for both single-TI (r2 = 0.90), and multi-TI ASL (r2 = 0.92). Single-TI ASL gave a higher estimate of whole-kidney RBF compared to multi-TI ASL (mean bias, 29.3 ml/min/100 g; p <0.001). Using multi-TI ASL, the median T1 of renal cortex was shorter than that of medulla (799.6 ms vs 807.1 ms, p = 0.01), and mean whole-kidney BAT was 269.7 ± 56.5 ms. GTN had an effect on systolic blood pressure (p < 0.05) but the change in RBF was not significant. CONCLUSIONS Free-breathing multi-TI renal ASL is feasible and reproducible at 3 T, providing simultaneous measurement of renal perfusion, haemodynamic parameters and tissue characteristics at baseline and during pharmacological challenge. KEY POINTS • Multiple inversion time arterial spin labelling (ASL) of the kidneys is feasible and reproducible at 3 T. • This approach allows simultaneous mapping of renal perfusion, bolus arrival time and tissue T 1 during free breathing. • This technique enables repeated measures of renal haemodynamic characteristics during pharmacological challenge.
Collapse
|
3
|
Multimodal population brain imaging in the UK Biobank prospective epidemiological study. Nat Neurosci 2016; 19:1523-1536. [PMID: 27643430 PMCID: PMC5086094 DOI: 10.1038/nn.4393] [Citation(s) in RCA: 936] [Impact Index Per Article: 117.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Accepted: 08/25/2016] [Indexed: 01/17/2023]
Abstract
Medical imaging has enormous potential for early disease prediction, but is impeded by the difficulty and expense of acquiring data sets before symptom onset. UK Biobank aims to address this problem directly by acquiring high-quality, consistently acquired imaging data from 100,000 predominantly healthy participants, with health outcomes being tracked over the coming decades. The brain imaging includes structural, diffusion and functional modalities. Along with body and cardiac imaging, genetics, lifestyle measures, biological phenotyping and health records, this imaging is expected to enable discovery of imaging markers of a broad range of diseases at their earliest stages, as well as provide unique insight into disease mechanisms. We describe UK Biobank brain imaging and present results derived from the first 5,000 participants' data release. Although this covers just 5% of the ultimate cohort, it has already yielded a rich range of associations between brain imaging and other measures collected by UK Biobank.
Collapse
|
4
|
Quantifying the Area at Risk in Reperfused ST-Segment-Elevation Myocardial Infarction Patients Using Hybrid Cardiac Positron Emission Tomography-Magnetic Resonance Imaging. Circ Cardiovasc Imaging 2016; 9:e003900. [PMID: 26926269 DOI: 10.1161/circimaging.115.003900] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Hybrid positron emission tomography and magnetic resonance allows the advantages of magnetic resonance in tissue characterizing the myocardium to be combined with the unique metabolic insights of positron emission tomography. We hypothesized that the area of reduced myocardial glucose uptake would closely match the area at risk delineated by T2 mapping in ST-segment-elevation myocardial infarction patients. METHODS AND RESULTS Hybrid positron emission tomography and magnetic resonance using (18)F-fluorodeoxyglucose (FDG) for glucose uptake was performed in 21 ST-segment-elevation myocardial infarction patients at a median of 5 days. Follow-up scans were performed in a subset of patients 12 months later. The area of reduced FDG uptake was significantly larger than the infarct size quantified by late gadolinium enhancement (37.2±11.6% versus 22.3±11.7%; P<0.001) and closely matched the area at risk by T2 mapping (37.2±11.6% versus 36.3±12.2%; P=0.10, R=0.98, bias 0.9±4.4%). On the follow-up scans, the area of reduced FDG uptake was significantly smaller in size when compared with the acute scans (19.5 [6.3%-31.8%] versus 44.0 [21.3%-55.3%]; P=0.002) and closely correlated with the areas of late gadolinium enhancement (R 0.98) with a small bias of 2.0±5.6%. An FDG uptake of ≥45% on the acute scans could predict viable myocardium on the follow-up scan. Both transmural extent of late gadolinium enhancement and FDG uptake on the acute scan performed equally well to predict segmental wall motion recovery. CONCLUSIONS Hybrid positron emission tomography and magnetic resonance in the reperfused ST-segment-elevation myocardial infarction patients showed reduced myocardial glucose uptake within the area at risk and closely matched the area at risk delineated by T2 mapping. FDG uptake, as well as transmural extent of late gadolinium enhancement, acutely can identify viable myocardial segments.
Collapse
|
5
|
Abstract
BACKGROUND UK Biobank's ambitious aim is to perform cardiovascular magnetic resonance (CMR) in 100,000 people previously recruited into this prospective cohort study of half a million 40-69 year-olds. METHODS/DESIGN We describe the CMR protocol applied in UK Biobank's pilot phase, which will be extended into the main phase with three centres using the same equipment and protocols. The CMR protocol includes white blood CMR (sagittal anatomy, coronary and transverse anatomy), cine CMR (long axis cines, short axis cines of the ventricles, coronal LVOT cine), strain CMR (tagging), flow CMR (aortic valve flow) and parametric CMR (native T1 map). DISCUSSION This report will serve as a reference to researchers intending to use the UK Biobank resource or to replicate the UK Biobank cardiovascular magnetic resonance protocol in different settings.
Collapse
|
6
|
Quantification of Left Ventricular Interstitial Fibrosis in Asymptomatic Chronic Primary Degenerative Mitral Regurgitation. Circ Cardiovasc Imaging 2014; 7:946-53. [DOI: 10.1161/circimaging.114.002397] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background—
The optimum timing of surgery in asymptomatic patients with chronic severe primary degenerative mitral regurgitation (MR) remains controversial, and further markers are needed to improve decision-making. There are limited data that wall stress is increased in MR and may result in ventricular fibrosis. We investigated the hypothesis that chronic volume overload in MR is a stimulus for myocardial fibrosis using T1-mapping cardiac MRI.
Methods and Results—
A cross-sectional study of 35 patients (age 60±14 years) with asymptomatic moderate and severe primary degenerative MR (mean effective regurgitant orifice area, 0.45±0.25 cm)
2
with no class I indication for surgery were compared with age and sex controls. Subjects were studied with cardiopulmonary exercise testing, echocardiography, and cardiac MRI.
Longitudinal and circumferential myocardial deformation was reduced with MR when left ventricular ejection fraction (67%±10%) and N-terminal pro B Natriuretic peptide (126 [76–428] ng/L) were within the normal range. Myocardial extracellular volume was increased (0.32±0.07 versus 0.25±0.02,
P
<0.01) and was associated with increased left ventricular end-systolic volume index (
r
=0.62,
P
<0.01), left atrial volume index (
r
=0.41,
P
<0.05) but lower left ventricular ejection fraction (
r
=−0.60,
P
<0.01), longitudinal function (mitral annular plane systolic excursion,
r
=−0.46,
P
<0.01), and peak V
O
2 max
(
r
=−0.51,
P
<0.05). In a multivariable regression model, left ventricular end-systolic volume index and left atrial volume index were independent predictors of extracellular volume (
r
2
=0.42,
P
<0.01).
Conclusions—
Patients with asymptomatic MR demonstrate a spectrum of myocardial fibrosis associated with reduced myocardial deformation and reduced exercise capacity. Future work is warranted to investigate whether left ventricle fibrosis affects clinical outcomes.
Collapse
|
7
|
Voxel-wise quantification of myocardial blood flow with cardiovascular magnetic resonance: effect of variations in methodology and validation with positron emission tomography. J Cardiovasc Magn Reson 2014; 16:11. [PMID: 24460930 PMCID: PMC3904701 DOI: 10.1186/1532-429x-16-11] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2013] [Accepted: 01/13/2014] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND Quantitative assessment of myocardial blood flow (MBF) from cardiovascular magnetic resonance (CMR) perfusion images appears to offer advantages over qualitative assessment. Currently however, clinical translation is lacking, at least in part due to considerable disparity in quantification methodology. The aim of this study was to evaluate the effect of common methodological differences in CMR voxel-wise measurement of MBF, using position emission tomography (PET) as external validation. METHODS Eighteen subjects, including 9 with significant coronary artery disease (CAD) and 9 healthy volunteers prospectively underwent perfusion CMR. Comparison was made between MBF quantified using: 1. Calculated contrast agent concentration curves (to correct for signal saturation) versus raw signal intensity curves; 2. Mid-ventricular versus basal-ventricular short-axis arterial input function (AIF) extraction; 3. Three different deconvolution approaches; Fermi function parameterization, truncated singular value decomposition (TSVD) and first-order Tikhonov regularization with b-splines. CAD patients also prospectively underwent rubidium-82 PET (median interval 7 days). RESULTS MBF was significantly higher when calculated using signal intensity compared to contrast agent concentration curves, and when the AIF was extracted from mid- compared to basal-ventricular images. MBF did not differ significantly between Fermi and Tikhonov, or between Fermi and TVSD deconvolution methods although there was a small difference between TSVD and Tikhonov (0.06 mL/min/g). Agreement between all deconvolution methods was high. MBF derived using each CMR deconvolution method showed a significant linear relationship (p<0.001) with PET-derived MBF however each method underestimated MBF compared to PET (by 0.19 to 0.35 mL/min/g). CONCLUSIONS Variations in more complex methodological factors such as deconvolution method have no greater effect on estimated MBF than simple factors such as AIF location and observer variability. Standardization of the quantification process will aid comparison between studies and may help CMR MBF quantification enter clinical use.
Collapse
|
8
|
Alström syndrome: a paradigm for diffuse fibrosis and clinical progression. J Cardiovasc Magn Reson 2013. [PMCID: PMC3559749 DOI: 10.1186/1532-429x-15-s1-p159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
9
|
New "gold standard" for assessing myocardial oedema in STEMI? J Cardiovasc Magn Reson 2013. [PMCID: PMC3559609 DOI: 10.1186/1532-429x-15-s1-o70] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
10
|
T2 mapping vs T2 weighted imaging in the detection of myocardial oedema. J Cardiovasc Magn Reson 2012. [PMCID: PMC3305033 DOI: 10.1186/1532-429x-14-s1-p266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
|
11
|
Microvascular Resistance Predicts Myocardial Salvage and Infarct Characteristics in ST-Elevation Myocardial Infarction. J Am Heart Assoc 2012; 1:e002246. [PMID: 23130166 PMCID: PMC3487342 DOI: 10.1161/jaha.112.002246] [Citation(s) in RCA: 78] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2012] [Accepted: 05/15/2012] [Indexed: 11/16/2022]
Abstract
BACKGROUND The pathophysiology of myocardial injury and repair in patients with ST-elevation myocardial infarction is incompletely understood. We investigated the relationships among culprit artery microvascular resistance, myocardial salvage, and ventricular function. METHODS AND RESULTS The index of microvascular resistance (IMR) was measured by means of a pressure- and temperature-sensitive coronary guidewire in 108 patients with ST-elevation myocardial infarction (83% male) at the end of primary percutaneous coronary intervention. Paired cardiac MRI (cardiac magnetic resonance) scans were performed early (2 days; n=108) and late (3 months; n=96) after myocardial infarction. T(2)-weighted- and late gadolinium-enhanced cardiac magnetic resonance delineated the ischemic area at risk and infarct size, respectively. Myocardial salvage was calculated by subtracting infarct size from area at risk. Univariable and multivariable models were constructed to determine the impact of IMR on cardiac magnetic resonance-derived surrogate outcomes. The median (interquartile range) IMR was 28 (17-42) mm Hg/s. The median (interquartile range) area at risk was 32% (24%-41%) of left ventricular mass, and the myocardial salvage index was 21% (11%-43%). IMR was a significant multivariable predictor of early myocardial salvage, with a multiplicative effect of 0.87 (95% confidence interval 0.82 to 0.92) per 20% increase in IMR; P<0.001. In patients with anterior myocardial infarction, IMR was a multivariable predictor of early and late myocardial salvage, with multiplicative effects of 0.82 (95% confidence interval 0.75 to 0.90; P<0.001) and 0.92 (95% confidence interval 0.88 to 0.96; P<0.001), respectively. IMR also predicted the presence and extent of microvascular obstruction and myocardial hemorrhage. CONCLUSION Microvascular resistance measured during primary percutaneous coronary intervention significantly predicts myocardial salvage, infarct characteristics, and left ventricular ejection fraction in patients with ST-elevation myocardial infarction. (J Am Heart Assoc. 2012;1:e002246 doi: 10.1161/JAHA.112.002246).
Collapse
|
12
|
7 Tesla (T) human cardiovascular magnetic resonance imaging using FLASH and SSFP to assess cardiac function: validation against 1.5 T and 3 T. NMR IN BIOMEDICINE 2012; 25:27-34. [PMID: 21774009 PMCID: PMC3440016 DOI: 10.1002/nbm.1708] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2010] [Revised: 12/02/2010] [Accepted: 02/15/2011] [Indexed: 05/04/2023]
Abstract
We report the first comparison of cardiovascular magnetic resonance imaging (CMR) at 1.5 T, 3 T and 7 T field strengths using steady state free precession (SSFP) and fast low angle shot (FLASH) cine sequences. Cardiac volumes and mass measurements were assessed for feasibility, reproducibility and validity at each given field strength using FLASH and SSFP sequences. Ten healthy volunteers underwent retrospectively electrocardiogram (ECG) gated CMR at 1.5 T, 3 T and 7 T using FLASH and SSFP sequences. B1 and B0 shimming and frequency scouts were used to optimise image quality. Cardiac volume and mass measurements were not significantly affected by field strength when using the same imaging sequence (P > 0.05 for all parameters at 1.5 T, 3 T and 7 T). SSFP imaging returned larger end diastolic and end systolic volumes and smaller left ventricular masses than FLASH imaging at 7 T, and at the lower field strengths (P < 0.05 for each parameter). However, univariate general linear model analysis with fixed effects for sequence and field strengths found an interaction between imaging sequence and field strength (P = 0.03), with a smaller difference in volumes and mass measurements between SSFP and FLASH imaging at 7 T than 1.5 T and 3 T. SSFP and FLASH cine imaging at 7 T is technically feasible and provides valid assessment of cardiac volumes and mass compared with CMR imaging at 1.5 T and 3 T field strengths.
Collapse
|
13
|
Ultrafast Cine cardiac MRI in the assessment of left ventricular diastology. J Cardiovasc Magn Reson 2011. [PMCID: PMC3106507 DOI: 10.1186/1532-429x-13-s1-p342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
14
|
Clinical evaluation of inline motion correction for cardiac perfusion MRI. J Cardiovasc Magn Reson 2011. [PMCID: PMC3106815 DOI: 10.1186/1532-429x-13-s1-p54] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
15
|
Feasibility of ultrahigh field (7 Tesla) human cardiovascular magnetic resonance imaging to assess cardiac volumes and mass validated against 1.5 T and 3T field strengths. J Cardiovasc Magn Reson 2011. [PMCID: PMC3106449 DOI: 10.1186/1532-429x-13-s1-o45] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
16
|
|
17
|
Non-contrast-enhanced four-dimensional (4D) intracranial MR angiography: a feasibility study. Magn Reson Med 2010; 63:835-41. [PMID: 20187191 DOI: 10.1002/mrm.22220] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
T(1)-shortening contrast agents have been widely used in time-resolved magnetic resonance angiography. To match imaging data acquisition with the short time period of the first pass of contrast agent, temporal resolution and/or spatial resolution have to be compromised in many cases. In this study, a novel non-contrast-enhanced technique was developed for time-resolved magnetic resonance angiography. Alternating magnetization preparation was applied in two consecutive acquisitions of each measurement to eliminate the need for contrast media. Without the constraint of contrast media kinetics, temporal resolution is drastically improved from the order of a second as in conventional contrast-enhanced approach to tens of milliseconds (50.9 msec) in this study, without compromising spatial resolution. Initial results from volunteer studies demonstrate the feasibility of this method to depict anatomic structure and dynamic filling of main vessels in the head.
Collapse
|
18
|
Carotid arterial wall MRI at 3T using 3D variable-flip-angle turbo spin-echo (TSE) with flow-sensitive dephasing (FSD). J Magn Reson Imaging 2010; 31:645-54. [PMID: 20187208 DOI: 10.1002/jmri.22058] [Citation(s) in RCA: 97] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To evaluate the effectiveness of flow-sensitive dephasing (FSD) magnetization preparation in improving blood signal suppression of three-dimensional (3D) turbo spin-echo (TSE) sequence (SPACE) for isotropic high-spatial-resolution carotid arterial wall imaging at 3T. MATERIALS AND METHODS The FSD-prepared SPACE sequence (FSD-SPACE) was implemented by adding two identical FSD gradient pulses right before and after the first refocusing 180 degrees -pulse of the SPACE sequence in all three orthogonal directions. Nine healthy volunteers were imaged at 3T with SPACE, FSD-SPACE, and multislice T2-weighted 2D TSE coupled with saturation band (SB-TSE). Apparent carotid wall-lumen contrast-to-noise ratio (aCNR(w-l)) and apparent lumen area (aLA) at the locations with residual-blood (rb) signal shown on SPACE images were compared between SPACE and FSD-SPACE. Carotid aCNR(w-l) and lumen (LA) and wall area (WA) measured from FSD-SPACE were compared to those measured from SB-TSE. RESULTS Plaque-mimicking flow artifacts identified in seven carotids on SPACE images were eliminated on FSD-SPACE images. The FSD preparation resulted in slightly reduced aCNR(w-l) (P = 0.025), but significantly improved aCNR between the wall and rb regions (P < 0.001) and larger aLA (P < 0.001). Compared to SB-TSE, FSD-SPACE offered comparable aCNR(w-l) with much higher spatial resolution, shorter imaging time, and larger artery coverage. The LA and WA measurements from the two techniques were in good agreement based on intraclasss correlation coefficient (0.988 and 0.949, respectively; P < 0.001) and Bland-Altman analyses. CONCLUSION FSD-SPACE is a time-efficient 3D imaging technique for carotid arterial wall with superior spatial resolution and blood signal suppression.
Collapse
|
19
|
084 High field (7 Tesla) cardiovascular MRI: a feasibility and comparison study. BRITISH HEART JOURNAL 2010. [DOI: 10.1136/hrt.2010.196071.6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
20
|
Inline directionally independent magnitude of velocity maps calculated from 3D encoded phase contrast images. J Cardiovasc Magn Reson 2010. [DOI: 10.1186/1532-429x-12-s1-p242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
21
|
Evaluation of patients with systemic sclerosis prior to hematopoietic stem-cell transplantation using cardiac magnetic resonance imaging. J Cardiovasc Magn Reson 2010. [DOI: 10.1186/1532-429x-12-s1-p259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
22
|
Coronary MRA at 3 T using 3d multi-interleaved multi-echo acquisition with varpro fat-water separation. J Cardiovasc Magn Reson 2010. [DOI: 10.1186/1532-429x-12-s1-p42] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
23
|
Diagnostic performance of magnetic resonance venography in the detection of recanalization in patients with chronic cerebral venous sinus thrombus. Chin Med J (Engl) 2009; 122:2428-2432. [PMID: 20079154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023] Open
Abstract
BACKGROUND In the chronic stage of cerebral venous sinus thrombosis (CVST), recanalization can result in disparate MR appearances. We aimed to prospectively investigate the diagnostic accuracy of magnetic resonance venography (MRV) in the evaluation of the recanalization of CVST. METHODS This study prospectively evaluated the diagnostic performance of 2-dimensional time-of-flight (2D-TOF) MRV in thirty-two consecutive patients during a three- to six-month follow-up for CVST. Both 2D-TOF MRV and digital substraction angiography (DSA) were undertaken. Diagnostic accuracy of 2D-TOF MRV in the detection of recanalized thrombus was evaluated using DSA as the reference standard. RESULTS MRV and DSA were completed without complications in all 32 patients. The sensitivity, specificity, positive predictive value, and negative predictive value of 2D-TOF MRV for the detection of recanalization on a segmental basis were 91% (62/68), 93% (37/40), 95% (62/65), and 86% (37/43) respectively. CONCLUSION 2D-TOF MRV provides high sensitivity and specificity for the diagnosis of recanalized CVST segments.
Collapse
|
24
|
Breathhold time-resolved three-directional MR velocity mapping of aortic flow in patients after aortic valve-sparing surgery. J Magn Reson Imaging 2009; 29:569-75. [PMID: 19243038 DOI: 10.1002/jmri.21685] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To evaluate the utility of breathhold time-resolved three-directional MR velocity mapping for quantifying the restoration of normal flow patterns in patients after aortic valve-sparing surgery. MATERIALS AND METHODS Breathhold time-resolved three-directional MR velocity mapping was performed on 13 patients with aortic valve-sparing surgery. Ten healthy volunteers and 12 patients with ascending aortic aneurysm underwent the same MR examination for comparison. Aortic laminar flow, turbulent flow, and the presence of vortical flow in the sinuses of Valsalva were semiquantitatively assessed and statistically compared between the three groups of subjects. RESULTS The average score of laminar flow in the ascending aorta for patients with surgery was not significantly different from that of volunteers (P=0.210), but was significantly greater than that of patients with aneurysm (P<0.01). The average score of turbulent flow in patients with surgery was significantly smaller than that of patients with aneurysm (P<0.01). The presence of systolic vortical flow in the sinuses of Valsalva for patients with surgery was not significantly different from that of healthy volunteers (P=0.405) and patients with aneurysm (P=0.238). CONCLUSION Breathhold time-resolved three-directional MR velocity mapping allows for quantifying flow patterns in the aortic root and ascending aorta. Normal laminar flow in the ascending aorta and vortical flow in the sinuses of Valsalva can be restored in patients after aortic valve-sparing surgery.
Collapse
|
25
|
Renal transplant: nonenhanced renal MR angiography with magnetization-prepared steady-state free precession. Radiology 2009; 251:535-42. [PMID: 19261926 DOI: 10.1148/radiol.2512081094] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The institutional review board approved this HIPAA-compliant study and waived informed consent. The purpose was to investigate nonenhanced magnetic resonance (MR) angiography with steady-state free precession (SSFP) with inversion recovery for assessing renal arteries in patients with renal transplants. Thirteen recipients of renal transplants underwent SSFP MR angiography before contrast material-enhanced MR angiography. Three stenoses (two mild, one severe) were identified at SSFP MR angiography in agreement with findings at contrast-enhanced MR angiography. There was no significant difference in image quality between the two methods. Results suggest SSFP MR angiography permits image quality of renal transplant arteries and detection of arterial stenosis comparable with those at contrast-enhanced MR angiography.
Collapse
|
26
|
Pulmonary vein imaging with unenhanced three-dimensional balanced steady-state free precession MR angiography: initial clinical evaluation. Radiology 2009; 250:932-9. [PMID: 19164696 DOI: 10.1148/radiol.2502072137] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
PURPOSE To determine whether unenhanced magnetic resonance (MR) angiography performed with a three-dimensional (3D) segmented steady-state free precession (SSFP) sequence would be an alternative to contrast material-enhanced MR angiography for evaluating pulmonary veins (PVs) prior to and following radiofrequency (RF) ablation for atrial fibrillation. MATERIALS AND METHODS MR angiographic examinations of PVs, performed in 20 patients (nine men, 11 women; mean age, 56.4 years +/- 12.7 [standard deviation]), were retrospectively reviewed according to an institutional review board-approved protocol. The number of PVs and their orthogonal measurements obtained from the 3D SSFP images were compared with those obtained from contrast-enhanced MR angiography. Signal-to-noise and contrast-to-noise ratios were also compared. Qualitative assessment of both techniques was performed by independent reviewers who scored the image quality (on a scale of 1 to 5) on the basis of PV conspicuity. The presence of cardiac and extracardiac pathologic indicators was also determined. Bland-Altman and Wilcoxon signed rank statistical analyses were performed. RESULTS The mean difference in PV diameter measurements between contrast-enhanced MR angiography and 3D SSFP was -0.02 cm +/- 0.25. Signal-to-noise and contrast-to-noise ratios were higher for 3D SSFP images than for contrast-enhanced MR angiograms. Qualitatively, there was no significant difference in PV conspicuity between the techniques. Noncardiac pathologic indicators were detected in 10 of 20 patients on 3D SSFP images but not on contrast-enhanced MR angiograms. CONCLUSION Unenhanced PV MR angiography performed by using a free-breathing 3D SSFP technique is as accurate as contrast-enhanced MR angiography for measuring PV diameter. This technique can be used for patients in whom contrast-enhanced computed tomographic or MR angiography is contraindicated and may be sufficient in all patients.
Collapse
|
27
|
Accelerated real time 2D and segmented 3D cine imaging – whole heart approaches in a single breath hold. J Cardiovasc Magn Reson 2009. [PMCID: PMC7860885 DOI: 10.1186/1532-429x-11-s1-p225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
28
|
Exploring the promise land of 7 T for CMR with T-PAT accelerated imaging techniques – first results for real time cardiac function and tagging in volunteers. J Cardiovasc Magn Reson 2009. [PMCID: PMC7860858 DOI: 10.1186/1532-429x-11-s1-p146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
29
|
Improved image quality in subtraction based non-contrast MRA using automated soft tissue motion correction with BRACE. J Cardiovasc Magn Reson 2009. [PMCID: PMC7860744 DOI: 10.1186/1532-429x-11-s1-p84] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
30
|
1047 Time-resolved three-directional MR velocity mapping of aortic flow in patient follow-up after aortic valve-sparing surgery. J Cardiovasc Magn Reson 2008. [DOI: 10.1186/1532-429x-10-s1-a172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
31
|
48 TPAT accelerated myocardial tagging with a 32-channel coil. J Cardiovasc Magn Reson 2008. [DOI: 10.1186/1532-429x-10-s1-a49] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
32
|
159 3D Submillimeter isotropic resolution superficial femoral artery wall MRI using SPACE at 3.0 T. J Cardiovasc Magn Reson 2008. [DOI: 10.1186/1532-429x-10-s1-a60] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
33
|
146 Improved 3D SPACE carotid vessel wall imaging at 3.0 T. J Cardiovasc Magn Reson 2008. [DOI: 10.1186/1532-429x-10-s1-a47] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
34
|
Abstract
The implications of an increase in field strength, from 1.5 T to 3 T, for routine functional cardiac examinations have been systematically investigated. Flip angle optimization was carried out for identical SSFP and FLASH cine imaging sequences at 1.5 T and 3 T, which supported the use of 20 degrees (FLASH 1.5 T and 3 T) and >60 degrees (SSFP 1.5 T and 3 T). The optimized sequences were applied in a study of cardiac function in a group of ten normal volunteers. Both SSFP and FLASH sequences showed significant SNR increases in the myocardium and blood at 3 T compared with 1.5 T, increases of 48% and 30% (myocardium and blood, respectively) for the SSFP sequence and 19% and 13% for the FLASH sequence. The SSFP sequence also showed a significant increase in CNR (22%). Image quality assessment revealed that the SSFP acquisitions were superior to FLASH at both field strengths. Although SSFP contained more artifacts at 3 T, they would not prevent its clinical use. We conclude that cardiac functional examinations at 3 T should use SSFP sequences.
Collapse
|
35
|
The median cleft face syndrome with associated cleft mandible, bifid odontoid peg and agenesis of the anterior arch of atlas. Br J Oral Maxillofac Surg 1991; 29:279-81. [PMID: 1911680 DOI: 10.1016/0266-4356(91)90199-f] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
A case is reported of median cleft face syndrome with bifid tongue and odontoid peg and failure of formation of the anterior arch of the atlas. These are features which have not been reported previously. The preoperative CT demonstrated its potential to enhance our understanding of complex and rare craniofacial deformities.
Collapse
|