1
|
Conceptual design of Thomson scattering diagnostics for the COMPASS-U tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:083503. [PMID: 34470395 DOI: 10.1063/5.0043661] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2021] [Accepted: 07/22/2021] [Indexed: 06/13/2023]
Abstract
The Thomson scattering (TS) diagnostic, one of the key diagnostics used on the tokamaks around the world, is planned for the COMPASS-U tokamak, which is recently under design and construction in the Institute of Plasma Physics in Prague, Czech Republic. This tokamak is supposed to be a world-unique, high magnetic field device with hot walls, allowing for the study of the plasma exhaust in advanced operational scenarios and testing cutting-edge technologies relevant to future fusion reactors, e.g., use of liquid metals. The core and edge TS systems are planned to be designed and operational, with a limited performance, already in the early stage of the tokamak operation. In this contribution, requirements and the most important constraints defining the TS system design are presented. The impact of both the possible collection lens location and spatial resolution on the plasma pedestal observation is simulated. Design considerations also take into account the high-resolution TS core and edge systems available from the COMPASS tokamak, which will be reused. The collection lenses will be newly built. Extension of the detection system will complete the plasma radius coverage in the future. The divertor TS is considered for later periods.
Collapse
|
2
|
|
3
|
Conceptual design of tomographic soft X-ray detectors for COMPASS-U tokamak. FUSION ENGINEERING AND DESIGN 2021. [DOI: 10.1016/j.fusengdes.2021.112656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
4
|
Microwave reflectometer for density profile and turbulence measurements on the COMPASS tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:013515. [PMID: 32012635 DOI: 10.1063/1.5099345] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Accepted: 01/07/2020] [Indexed: 06/10/2023]
Abstract
The fast microwave reflectometer system on the COMPASS tokamak consists of an O-mode polarized K-band (18 GHz-26 GHz), Ka-band (26 GHz-40 GHz), and a part of U-band (40 GHz-54 GHz). The plasma density profile from the edge plasma area is measured using a fast sweeping rate up of to 6 µs of the probing wave. The processing of the reflected signal is realized by the heterodyne detection configuration based on the I/Q modulator. Two different methods of dynamic calibration of the required linear sweep frequency, together with static frequency and dispersion calibration, were used. The electron density profile was reconstructed by a spectrogram-based method with four sweeps on average. The system has the capability to measure the mid-plane low-field side electron density profile in the density range from 4 × 1018 m-3 to 3.6 × 1019 m-3. Experimental results obtained on COMPASS discharges are presented to demonstrate the performance of the diagnostics.
Collapse
|
5
|
Study for the microwave interferometer for high densities plasmas on COMPASS-U tokamak. FUSION ENGINEERING AND DESIGN 2019. [DOI: 10.1016/j.fusengdes.2019.03.051] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
6
|
|
7
|
Comparison of approaches to the electromagnetic analysis of COMPASS-U vacuum vessel during fast transients. FUSION ENGINEERING AND DESIGN 2019. [DOI: 10.1016/j.fusengdes.2019.03.185] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
8
|
Development of an ion beam detector for the atomic beam probe diagnostic. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:113506. [PMID: 30501297 DOI: 10.1063/1.5044529] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Accepted: 10/29/2018] [Indexed: 06/09/2023]
Abstract
The atomic beam probe diagnostic concept aims at measuring the edge magnetic field and through that edge current distribution in fusion plasmas by observing trajectories of an ion beam stemming from a diagnostic neutral beam. The diagnostic potentially has microsecond scale time resolution and can thus prove to be a powerful option to study fast changes in the edge plasma. A test detector has been installed on the COMPASS tokamak as an extension of the existing lithium beam diagnostic system. It employs a relatively simple concept of an array of conductive detection plates measuring the incident ion current, which is then amplified and converted to a voltage signal. The aim of the test detector is to experimentally examine the idea of the diagnostic and provide background data for design and installation of a final detector. Also, a numerical code based on the CUDA parallel computing platform has been developed for modeling lithium ion trajectories in the given COMPASS plasma discharges. We present the developments of the detector design and test measurements of the diagnostic performed both in a laboratory beam system and on the COMPASS tokamak.
Collapse
|
9
|
Observation and evaluation of the alignment of Thomson scattering systems. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:10C105. [PMID: 30399913 DOI: 10.1063/1.5038772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2018] [Accepted: 06/02/2018] [Indexed: 06/08/2023]
Abstract
Concerning plasma diagnostics based on Thomson scattering (TS), precise adjustment and proper alignment is of great importance in order to provide reliable and accurate measurements. Any misalignment could result in an incorrectly determined plasma density or prevent the measurement with this type of diagnostic altogether. Suitable means of alignment monitoring should be integrated into each TS diagnostic system. Variations of commonly used methods are discussed in this article. Correlation of results from alignment control with performed measurements of vibrations on the COMPASS tokamak is presented. Various techniques of optimization of alignment monitoring are shown. The optimal technique, which could be accommodated during the construction of TS diagnostic systems in future fusion devices, is proposed.
Collapse
|
10
|
Fly ash-derived MCM-41 as a low-cost silica support for polyethyleneimine in post-combustion CO2 capture. J CO2 UTIL 2017. [DOI: 10.1016/j.jcou.2017.09.015] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
11
|
MALT1 Protease Activation Triggers Acute Disruption of Endothelial Barrier Integrity via CYLD Cleavage. Cell Rep 2017; 17:221-232. [PMID: 27681433 DOI: 10.1016/j.celrep.2016.08.080] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2015] [Revised: 07/14/2016] [Accepted: 08/23/2016] [Indexed: 12/26/2022] Open
Abstract
Microvascular endothelial cells maintain a tight barrier to prevent passage of plasma and circulating immune cells into the extravascular tissue compartment, yet endothelial cells respond rapidly to vasoactive substances, including thrombin, allowing transient paracellular permeability. This response is a cornerstone of acute inflammation, but the mechanisms responsible are still incompletely understood. Here, we demonstrate that thrombin triggers MALT1 to proteolytically cleave cylindromatosis (CYLD). Fragmentation of CYLD results in microtubule disruption and a cascade of events leading to endothelial cell retraction and an acute permeability response. This finding reveals an unexpected role for the MALT1 protease, which previously has been viewed mostly as a driver of pro-inflammatory NF-κB signaling in lymphocytes. Thus, MALT1 not only promotes immune cell activation but also acutely regulates endothelial cell biology, actions that together facilitate tissue inflammation. Pharmacologic inhibition of MALT1 may therefore have synergistic impact by targeting multiple disparate steps in the overall inflammatory response.
Collapse
|
12
|
|
13
|
Electromagnetic ELM and inter-ELM filaments detected in the COMPASS Scrape-Off Layer. NUCLEAR MATERIALS AND ENERGY 2017. [DOI: 10.1016/j.nme.2016.12.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
14
|
Power deposition on misaligned edges in COMPASS. NUCLEAR MATERIALS AND ENERGY 2017. [DOI: 10.1016/j.nme.2016.09.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
15
|
Tungsten dust remobilization under steady-state and transient plasma conditions. NUCLEAR MATERIALS AND ENERGY 2017. [DOI: 10.1016/j.nme.2016.10.021] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
16
|
Filamentary probe on the COMPASS tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2017; 88:035106. [PMID: 28372420 DOI: 10.1063/1.4977591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
This paper describes a new filamentary probe recently introduced on the COMPASS tokamak. It allows the measurement of electrostatic and magnetic properties of the filaments and their changes in dependence on distance from the separatrix in the region between a divertor and midplane. The probe head is mounted on a manipulator moving the probe radially on a shot-to-shot basis. This configuration is suitable for the long term statistical measurement of the plasma filaments and the measurement of their evolution during their propagation from the separatrix to the wall. The basics of the filamentary probe construction, the evolution of the plasma parameters, and first conditional averages of the plasma filaments in the scrape-off layer of the COMPASS tokamak during the L-mode regime are presented.
Collapse
|
17
|
Fitting of the Thomson scattering density and temperature profiles on the COMPASS tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:11E536. [PMID: 27910584 DOI: 10.1063/1.4961554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A new technique for fitting the full radial profiles of electron density and temperature obtained by the Thomson scattering diagnostic in H-mode discharges on the COMPASS tokamak is described. The technique combines the conventionally used modified hyperbolic tangent function for the edge transport barrier (pedestal) fitting and a modification of a Gaussian function for fitting the core plasma. Low number of parameters of this combined function and their straightforward interpretability and controllability provide a robust method for obtaining physically reasonable profile fits. Deconvolution with the diagnostic instrument function is applied on the profile fit, taking into account the dependence on the actual magnetic configuration.
Collapse
|
18
|
EP-1899: Evaluation of SEMAC MRI metal artifact reduction for orthopaedic implants in radiotherapy planning. Radiother Oncol 2016. [DOI: 10.1016/s0167-8140(16)33150-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
19
|
Profile measurements of the electron temperature on the ASDEX Upgrade, COMPASS, and ISTTOK tokamak using Thomson scattering, triple, and ball-pen probes. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:043510. [PMID: 27131677 DOI: 10.1063/1.4945797] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The ball-pen probe (BPP) technique is used successfully to make profile measurements of the electron temperature on the ASDEX Upgrade (Axially Symmetric Divertor Experiment), COMPASS (COMPact ASSembly), and ISTTOK (Instituto Superior Tecnico TOKamak) tokamak. The electron temperature is provided by a combination of the BPP potential (ΦBPP) and the floating potential (Vfl) of the Langmuir probe (LP), which is compared with the Thomson scattering diagnostic on ASDEX Upgrade and COMPASS. Excellent agreement between the two diagnostics is obtained for circular and diverted plasmas and different heating mechanisms (Ohmic, NBI, ECRH) in deuterium discharges with the same formula Te = (ΦBPP - Vfl)/2.2. The comparative measurements of the electron temperature using BPP/LP and triple probe (TP) techniques on the ISTTOK tokamak show good agreement of averaged values only inside the separatrix. It was also found that the TP provides the electron temperature with significantly higher standard deviation than BPP/LP. However, the resulting values of both techniques are well in the phase with the maximum of cross-correlation function being 0.8.
Collapse
|
20
|
Metabolic Tumor Volume Changes Measured by 18F-FDG-PET/CT After 1 Cycle of Induction Chemotherapy Is an Early Predictor of Radical Chemoradiation Therapy Outcome in Head and Neck Squamous Cell Carcinoma. Int J Radiat Oncol Biol Phys 2016. [DOI: 10.1016/j.ijrobp.2015.12.165] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
21
|
|
22
|
Edge Thomson scattering diagnostic on COMPASS tokamak: installation, calibration, operation, improvements. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:11E431. [PMID: 25430338 DOI: 10.1063/1.4893995] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The core Thomson scattering diagnostic (TS) on the COMPASS tokamak was put in operation and reported earlier. Implementation of edge TS, with spatial resolution along the laser beam up to ∼1/100 of the tokamak minor radius, is presented now. The procedure for spatial calibration and alignment of both core and edge systems is described. Several further upgrades of the TS system, like a triggering unit and piezo motor driven vacuum window shutter, are introduced as well. The edge TS system, together with the core TS, is now in routine operation and provides electron temperature and density profiles.
Collapse
|
23
|
Use of soft x-ray diagnostic on the COMPASS tokamak for investigations of sawteeth crash neighborhood and of plasma position using fast inversion methods. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:11E433. [PMID: 25430340 DOI: 10.1063/1.4894528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The soft x-ray diagnostic is suitable for monitoring plasma activity in the tokamak core, e.g., sawtooth instability. Moreover, spatially resolved measurements can provide information about plasma position and shape, which can supplement magnetic measurements. In this contribution, fast algorithms with the potential for a real-time use are tested on the data from the COMPASS tokamak. In addition, the soft x-ray data are compared with data from other diagnostics in order to discuss possible connection between sawtooth instability on one side and the transition to higher confinement mode, edge localized modes and productions of runaway electrons on the other side.
Collapse
|
24
|
Dichloroacetate induces autophagy in colorectal cancer cells and tumours. Br J Cancer 2014; 111:375-85. [PMID: 24892448 PMCID: PMC4102941 DOI: 10.1038/bjc.2014.281] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Revised: 04/22/2014] [Accepted: 04/30/2014] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Dichloroacetate (DCA) has been found to have antitumour properties. METHODS We investigated the cellular and metabolic responses to DCA treatment and recovery in human colorectal (HT29, HCT116 WT and HCT116 Bax-ko), prostate carcinoma cells (PC3) and HT29 xenografts by flow cytometry, western blotting, electron microscopy, (1)H and hyperpolarised (13)C-magnetic resonance spectroscopy. RESULTS Increased expression of the autophagy markers LC3B II was observed following DCA treatment both in vitro and in vivo. We observed increased production of reactive oxygen species (ROS) and mTOR inhibition (decreased pS6 ribosomal protein and p4E-BP1 expression) as well as increased expression of MCT1 following DCA treatment. Steady-state lactate excretion and the apparent hyperpolarised [1-(13)C] pyruvate-to-lactate exchange rate (k(PL)) were decreased in DCA-treated cells, along with increased NAD(+)/NADH ratios and NAD(+). Steady-state lactate excretion and k(PL) returned to, or exceeded, control levels in cells recovered from DCA treatment, accompanied by increased NAD(+) and NADH. Reduced k(PL) with DCA treatment was found in HT29 tumour xenografts in vivo. CONCLUSIONS DCA induces autophagy in cancer cells accompanied by ROS production and mTOR inhibition, reduced lactate excretion, reduced k(PL) and increased NAD(+)/NADH ratio. The observed cellular and metabolic changes recover on cessation of treatment.
Collapse
|
25
|
Timing and triggering of the Thomson scattering diagnostics on the COMPASS tokamak. FUSION ENGINEERING AND DESIGN 2014. [DOI: 10.1016/j.fusengdes.2014.03.031] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
26
|
|
27
|
|
28
|
SU-E-J-107: SEMAC MRI Metal Artifact Reduction Technique for Radiotherapy Planning Using CT/MRI Fusion. Med Phys 2013. [DOI: 10.1118/1.4814319] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
29
|
High-resolution Thomson scattering system on the COMPASS tokamak: evaluation of plasma parameters and error analysis. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:10E350. [PMID: 23127007 DOI: 10.1063/1.4743956] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The electron density and temperature profiles measured by the Thomson scattering diagnostic on the COMPASS tokamak are used for estimation of electron kinetic energy, energy confinement time, and effective charge number Z(eff). Data are compared with the line-integrated electron density measured by a microwave interferometer in an ohmically heated plasma with a circular cross section. An error analysis of both electron temperature and density are performed by two methods-a constant chi-square boundaries method and a Monte Carlo simulation, determining asymmetrical error bars for the electron temperature.
Collapse
|
30
|
Personnel protection during the operation of Thomson scattering laser system on COMPASS tokamak. FUSION ENGINEERING AND DESIGN 2011. [DOI: 10.1016/j.fusengdes.2011.02.073] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
31
|
Progress of development of Thomson scattering diagnostic system on COMPASS. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2010; 81:10D531. [PMID: 21033886 DOI: 10.1063/1.3494378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A new Thomson scattering diagnostic system has been designed and is being built now on the COMPASS tokamak at the Institute of Plasma Physics ASCR in Prague (IPP Prague) in the Czech Republic. This contribution focuses on design, development, and installation of the light collection and detection system. High spatial resolution of 3 mm will be achieved by a combination of design of collection optics and connected polychromators. Imaging characteristics of both core and edge plasma collection objectives are described and fiber backplane design is presented. Several calibration procedures are discussed. The operational deployment of the Thomson scattering diagnostic is planned by the end of 2010.
Collapse
|
32
|
Laser system for high resolution Thomson scattering diagnostics on the COMPASS tokamak. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2010; 81:10D511. [PMID: 21033866 DOI: 10.1063/1.3460450] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A new Thomson scattering diagnostic has been designed and is currently being installed on the COMPASS tokamak in IPP Prague in the Czech Republic. The requirements for this system are very stringent with approximately 3 mm spatial resolution at the plasma edge. A critical part of this diagnostic is the laser source. To achieve the specified parameters, a multilaser solution is utilized. Two 30 Hz 1.5 J Nd:YAG laser systems, used at the fundamental wavelength of 1064 nm, are located outside the tokamak area at a distance of 20 m from the tokamak. The design of the laser beam transport path is presented. The approach leading to a final choice of optimal focusing optics is given. As well as the beam path to the tokamak, a test path of the same optical length was built. Performance tests of the laser system carried out using the test path are described.
Collapse
|
33
|
Abstract
Polyoma virus nephropathy is an important cause of graft dysfunction in kidney transplant recipients and screening to prevent disease has been advocated. Although screening incurs new costs, our hypothesis is that savings from less immunosuppression in those with positive screening tests could pay for overall costs of screening. In 134 consecutive recipients, polyoma virus (positive decoy cells) was detected in the urine of 34 (25.4%) individuals over a 2-year follow-up. Of these 34, 11 had a plasma BK PCR of >7700 copies/mL. Immunosuppression was reduced stepwise in these patients until viral loads fell <1000/mL. Overall screening costs (including extra plasma PCR testing) were estimated at $33,450. Those with positive PCR had greater reductions in annual immunosuppression costs by year 2 ($6452 vs. $2799, p = 0.0015) compared to those with negative screens. At the end of the 2-year period, 61% of the screening costs were covered by less immunosuppressant costs. At the end of 30 months there were net savings. In summary, reductions in immunosuppression cover the cost of screening for polyoma viral infection. Longer-term follow-up is needed to ensure patient outcomes remain acceptable.
Collapse
|
34
|
Abstract
The study examines selection for kidney transplantation and determines who are referred, how many had contraindications and whether comorbidity indices predict transplant status. Of 113 consecutive adult incident end-stage renal disease (ESRD) patients at this single center 47 (41.6%) were referred. Using published guidelines, 48 (42.5%) had a specific contraindication. However 26 (23%) were neither referred nor had contraindications. An ESRD mortality score, acute renal failure status and albumin were independent predictors of referral but only the mortality score was predictive of contraindication status. The Charlson and ESRD comorbidity indices were less predictive of contraindication or referral status. In a comparison of patients who were Candidates (referred and no contraindication, n = 39) compared to those who were Neither (not referred and no contraindications, n = 26), age was the most discriminating factor (c = 0.99, 95% CI 0.97-1.00). Comorbidity and mortality indices were inferior. Neither patients were older (75 +/- 7 years) and had comorbidity scores that were higher than Candidates but similar to those with contraindications (ESRD index; Neither 3.3 +/- 2.5, Candidate 1.4 +/- 1.8, and contraindication 4.1 +/- 3.4). Comorbitity indices do not help explain selection practices whereas age is an important discriminator. How many Neither patients would benefit from transplantation is not known.
Collapse
|
35
|
Survey of porcine rotavirus G and P genotype in Poland and the United States using RT-PCR. JOURNAL OF VETERINARY MEDICINE. B, INFECTIOUS DISEASES AND VETERINARY PUBLIC HEALTH 2002; 49:373-8. [PMID: 12449245 DOI: 10.1046/j.1439-0450.2002.00572.x] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Porcine rotaviruses are a common cause of gastroenteritis. Several serotypes have been detected based on the two surface proteins VP4 (P-types) and VP7 (G-types). However, limited studies have been performed on the relative frequency of rotavirus types in diarrhetic pigs primarily because of the lack of availability of suitable methods. In this study, we describe a reverse transcriptase-polymerase chain reaction (RT-PCR) method for the typing of P and G types of rotavirus. This method allowed to detect G and P types in 96.8 and 87.1% of isolates collected in the United States, respectively and in 54.5 and 38.6% of isolates collected in Poland, respectively. Within the US specimens the G3, G4, G5, G9 and G10 types were detected in combination with P6 and P7 types while among Polish specimens only G3, G4 and G5 types in combination with P6 and P7 types were identified. In both instances the G4 and G5 were the most prevalent types. These studies show that a RT-PCR typing method is suitable for molecular epidemiological studies and that there is more diversity among porcine rotavirus than previously reported.
Collapse
|
36
|
Effect of recipient sensitization (peak PRA) on graft outcome in haploidentical living related kidney transplants. Clin Transplant 2000; 14:212-7. [PMID: 10831079 DOI: 10.1034/j.1399-0012.2000.140306.x] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE To evaluate the influence of pre-transplant recipient sensitization on the outcome of 1-haploidentical live related donor (LRD) kidney transplants. METHOD We reviewed 141 consecutive cyclosporine-treated adult haploidentical first transplants for which panel reactive antibody (PRA) levels were available. Patients were divided into three groups according to their peak PRA levels: group I, PRA = 0 (n = 97); group II, PRA = 1-50% (n = 24); and group III, PRA = 51-100% (n = 20). RESULTS Differences in PRA were associated with significant differences in short- and longer-term graft survival, unrelated to patient survival. Graft survival at 1, 3, and 5 yr was only 74, 40, and 27% in group III, compared to 92, 87, and 52% in group II, and 96, 91, and 85% in group I (p < 0.001). Increasing PRA was associated with shorter time-to-graft failure. In group III, 20% lost their transplant from acute rejection in the first 6 months, versus 4% in group II and 3% in group I (p < 0.01). Graft survival in group II diverged from that of group I only after 3 yr, due to an increase in loss from chronic rejection. Hospitalization was longer in group III, in association with a significantly higher incidence of acute rejection during the first 3 months after transplantation (p < 0.02). Serum creatinine was higher in sensitized than nonsensitized patients at all time points. CONCLUSIONS Sensitization has a significant negative impact on the outcome of haploidentical LRD kidney transplants. Sensitized potential recipients and their potential donors should be aware of this in arriving at informed decision-making for transplantation. These patients may benefit from more sensitive cross-match testing, more intense or more novel immunosuppression, or immunomodulation to modify their immune responsiveness.
Collapse
|
37
|
Neoral monitoring by simplified sparse sampling area under the concentration-time curve: its relationship to acute rejection and cyclosporine nephrotoxicity early after kidney transplantation. Transplantation 1999; 68:55-62. [PMID: 10428267 DOI: 10.1097/00007890-199907150-00011] [Citation(s) in RCA: 336] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Cyclosporine (CsA) dosing is traditionally based on trough blood levels (C0) rather than area under the concentration-time curve (AUC), although AUC correlates better with posttransplantation clinical events. For Neoral, AUC based on limited sampling correlates closely with full 12-hr AUC. The purpose of our study was to correlate C0 with AUC based on CsA levels at 0, 1, 2, 3, and 4 hr after dose (PK0-4) and to compare this AUC with C0 in predicting acute rejection (AR) and acute cyclosporine nephrotoxicity (CsANT) in de novo first kidney transplant patients. METHODS PK0-4 was done 2-4 days after starting Neoral for 156 patients. All received CsA-based triple-drug immunosuppression without antibody induction. AUC was calculated as projected 12-hr (AUC0-12) and actual 4-hr (AUC0-4) from the PK0-4 using the parallel trapezoid rule. Neoral dosing was based on C0 not AUC. AUC was retrospectively compared with C0 as a predictor of AR and CsANT during the first 90 days. RESULTS C0 correlated poorly with AUC0-12 and AUC0-4 (r=0.61 and r=0.42). C0 (mean+/-SEM) levels were not significantly different in 34 patients with and 109 without AR (293+/-21 vs. 294+/-11 microg/L, P=0.95). AUC0-12 and AUC0-4 were significantly lower in patients with than without AR (AUC0-12 9090+/-598 vs. 10608+/-336 microg x h/L, P=0.01; AUC0-4 3934+/-306 vs. 4802+/-166 microg.h/L, P=0.006). In stepwise regression analysis only AUC0-12 or AUC0-4 (P=0.03/P=0.02) and delayed graft function (P=0.007) predicted AR. AUC0-12, AUC0-4, and C0 were all significantly higher in patients with CsANT than without CsANT (AUC0-12 11746+/-650 vs. 10023+/-301 microg x h/L, P=0.01; AUC0-4 5270+/-358 vs. 4474+/-150 microg x h/L, P=0.01; C0 343+/-18 vs. 287+/-10 microg/L, P=0.01), but in stepwise regression analysis C0 was not an independent predictor of CsANT. Patients with AUC0-12 in the range of 9500 to 11500 microg x h/L or AUC0-4 between 4400 and 5500 microg x h/L had the lowest incidence of AR (13% and 7%, respectively) without significantly higher risk for CsANT. CONCLUSION C0 correlates poorly with AUC based on PK0-4. Early AUC based on PK0-4 is more closely associated with AR and CsANT than is C0. Our data suggest that a target AUC0-12 of 9500-11500 or AUC0-4 of 4400-5500 microg x h/L may provide optimal Neoral immunosuppression.
Collapse
|
38
|
The morbidity of prolonged wound drainage after kidney transplantation. J Urol 1999; 161:1467-9. [PMID: 10210374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
PURPOSE The consequences of prolonged wound drainage, defined as extravasation of more than 50 ml. fluid daily for more than 1 week through a drain or wound after renal transplantation, have not been well described in the literature. We examine the association of prolonged wound drainage with other clinical events, and its impact on hospitalization, and patient and graft survival. MATERIALS AND METHODS We prospectively documented prolonged wound drainage in 392 recipients of cadaver and live renal transplants from July 1993 to December 1997. Potential risk factors, associated outcomes within the first 6 months and effect on length of hospital stay due to prolonged wound drainage were determined. RESULTS Prolonged wound drainage was significantly associated with pre-transplantation weight, weight gain by post-transplantation day 3, delayed graft function and continuous ambulatory peritoneal dialysis on univariate analysis but only with delayed graft function (odds ratio 2.8, 95% confidence intervals 1.4 to 5.6) on multivariate analysis. Post-transplantation lymphoceles (5.2, 9 to 14), wound infection (27, 5.7 to 130) and wound dehiscence (5.8, 1.7 to 20) were associated with prolonged wound drainage. Patients with prolonged wound drainage stayed 8.7 additional days during the first hospitalization and overall 11.3 additional days during the first 6 months after transplantation independent of other co-morbid events, such as delayed graft function, rejection or cytomegalovirus disease. CONCLUSIONS Prolonged wound drainage is an important post-renal transplantation event that impacts patient outcomes and hospital resource use. Efforts to prevent this complication should be considered.
Collapse
|
39
|
Subclasses of cyclic GMP-specific phosphodiesterase and their role in regulating the effects of atrial natriuretic factor. Hypertension 1990; 15:528-40. [PMID: 2158939 DOI: 10.1161/01.hyp.15.5.528] [Citation(s) in RCA: 25] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Two subclasses of cyclic guanosine monophosphate (GMP)-specific phosphodiesterases were identified in vascular tissue from several beds. The activity of one subclass (phosphodiesterase IB) was stimulated severalfold by calmodulin and selectively inhibited by the phosphodiesterase inhibitor TCV-3B. The activity of the other subclass (phosphodiesterase IC) was not stimulated by calmodulin and was selectively inhibited by the phosphodiesterase inhibitor M&B 22,948. To assess the involvement of both subclasses in regulating cyclic GMP-dependent responses, the ability of TCV-3B and M&B 22,948 to potentiate the in vitro and in vivo responses to the endogenous guanylate cyclase stimulator atrial natriuretic factor (ANF) was evaluated. Both TCV-3B and M&B 22,948 relaxed isolated rabbit aortic and pulmonary artery rings and also potentiated the relaxant effect of ANF. In addition, both inhibitors produced small increases in urine flow and sodium excretion in anesthetized rats and potentiated the diuretic and natriuretic responses to exogenous ANF. M&B 22,948 (30 micrograms/kg/min) produced a threefold increase in the natriuretic response to simultaneously administered ANF, and TCV-3B (10 micrograms/kg/min) produced a twofold increase in the response to ANF. The results of the present experiments suggest that both the calmodulin-sensitive and calmodulin-insensitive subclasses of cyclic GMP-specific phosphodiesterase play a role in regulating the in vitro and in vivo response to ANF.
Collapse
|
40
|
O-methylation of isoproterenol by the endothelium of the rabbit thoracic aorta. BLOOD VESSELS 1986; 23:279-87. [PMID: 3790744 DOI: 10.1159/000158655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
We have examined the influence of endothelial cell removal upon the O-methylation of the isomers of isoproterenol in the isolated rabbit aorta. Endothelial cells were removed by mechanically abrading isolated segments of rabbit aorta. The latter procedure resulted in the abolition of acetylcholine-mediated relaxation of tissues, a process dependent upon the presence of endothelial cells. In addition, histological staining and electron-microscopic analysis indicated the presence of endothelial cells in tissues not subjected to mechanical abrasion and the absence of endothelial cells in tissues subjected to abrasion. Moreover, ultrastructural analysis revealed that the influence of abrasion was limited to the luminal side of the internal elastic lamina. The removal of endothelial cells from the isolated rabbit aorta was associated with a decrease (approximately 30%) in the O-methylation of the isomers of isoproterenol. Inhibition of the extraneuronal uptake process with deoxycorticosterone (DOCA) produced a predicted decrease in the O-methylation of isoproterenol in tissues with the endothelium intact. In the absence of endothelial cells, the inhibition of the O-methylation of isoproterenol mediated by DOCA persisted. The results suggest that the O-methylation of catecholamines can occur in both medial and endothelial structures in this blood vessel and support the results of immunohistochemical studies that suggested a presence of catechol-O-methyltransferase in vascular endothelial structures. In addition, the findings exclude a possibility that the extraneuronal uptake process for catecholamines resides exclusively in endothelial structures. The functional consequences of vascular endothelial cell O-methylation are discussed.
Collapse
|
41
|
The effect of Dianabol on certain cell energy processes in postirradiation disease. STRAHLENTHERAPIE 1974; 148:168-72. [PMID: 4373879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
42
|
Studies on the radioprotective effects of phosphororganic compounds combined with substances of different active centres and action mechanisms. STRAHLENTHERAPIE 1974; 148:116-9. [PMID: 4439427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
43
|
[Further studies on the radioprotective mode of action of anabolic steroids]. STRAHLENTHERAPIE 1973; 145:443-52. [PMID: 4704368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
44
|
[Radioprotective effects and action mechanism of phenchlorphos]. STRAHLENTHERAPIE 1973; 145:187-96. [PMID: 4121059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
45
|
[Radioprotective effect of trichlorphone]. STRAHLENTHERAPIE 1973; 145:178-86. [PMID: 4694655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
46
|
[Studies on the enhancement of the radiation-protecting action of anabolic steroids]. STRAHLENTHERAPIE 1972; 143:559-69. [PMID: 5055954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
47
|
[Studies on the mechanism of the radiation-protective effect of anabolic steroids. II. Influence of dianabol on tissue respiration disorders and postradiologic toxemia]. STRAHLENTHERAPIE 1972; 143:444-53. [PMID: 5048780] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
48
|
[Studies on the mechanism of the radiation-protective effect of anabolic steroids. I. Influence of Dianabol on the postradiologic disorders of individual serum protein factors]. STRAHLENTHERAPIE 1972; 143:211-8. [PMID: 4114861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
49
|
[Studies on the radiation-protective effect of methandrostenolone in female rats]. STRAHLENTHERAPIE 1968; 135:459-63. [PMID: 5675754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
50
|
[Studies on the mechanism of action of the radiation-protective substance methandrostenolone. II. The dependence of the radiation-protective effect of methandrostenolone on its hypoxemic effect]. STRAHLENTHERAPIE 1965; 128:610-6. [PMID: 5885888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|