Ngu JCY, Shannon NB, Eu EW, Lee LS, Tan SS, Lim SKT, Ng FC, Chiow AKH. Technical insights to multivisceral resections using the da Vinci Xi.
ANZ J Surg 2023;
93:166-172. [PMID:
36129451 DOI:
10.1111/ans.18064]
[Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 09/05/2022] [Accepted: 09/11/2022] [Indexed: 11/30/2022]
Abstract
BACKGROUND
There have been few reports on the feasibility and safety of robotic multivisceral surgeries. The da Vinci Xi boasts significant upgrades that improve its applicability in combined resections. We report our early experience of multivisceral, multi-quadrant resections with the Xi system.
METHODS
Between May 2015 and August 2019, 13 multivisceral resections were performed. Patient demographics, procedural data, and perioperative outcomes were evaluated.
RESULTS
The procedures were completed at a median operative time of 290 (range, 210-535) minutes. The median postoperative length of hospital stay was 3.5 (range, 2-7) days. There was one case of readmission for anastomotic leak, but no positioning injuries, external robot arm collisions or issues arising from trocar position. There were no cases of perioperative mortality.
CONCLUSION
Multivisceral resections can be safely accomplished using the Xi. Further studies are necessary to ascertain whether there are benefits of the robotic approach over conventional laparoscopy in these complex cases.
Collapse