1
|
Properties of Cosmic-Ray Sulfur and Determination of the Composition of Primary Cosmic-Ray Carbon, Neon, Magnesium, and Sulfur: Ten-Year Results from the Alpha Magnetic Spectrometer. PHYSICAL REVIEW LETTERS 2023; 130:211002. [PMID: 37295095 DOI: 10.1103/physrevlett.130.211002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 03/28/2023] [Accepted: 04/27/2023] [Indexed: 06/12/2023]
Abstract
We report the properties of primary cosmic-ray sulfur (S) in the rigidity range 2.15 GV to 3.0 TV based on 0.38×10^{6} sulfur nuclei collected by the Alpha Magnetic Spectrometer experiment (AMS). We observed that above 90 GV the rigidity dependence of the S flux is identical to the rigidity dependence of Ne-Mg-Si fluxes, which is different from the rigidity dependence of the He-C-O-Fe fluxes. We found that, similar to N, Na, and Al cosmic rays, over the entire rigidity range, the traditional primary cosmic rays S, Ne, Mg, and C all have sizeable secondary components, and the S, Ne, and Mg fluxes are well described by the weighted sum of the primary silicon flux and the secondary fluorine flux, and the C flux is well described by the weighted sum of the primary oxygen flux and the secondary boron flux. The primary and secondary contributions of the traditional primary cosmic-ray fluxes of C, Ne, Mg, and S (even Z elements) are distinctly different from the primary and secondary contributions of the N, Na, and Al (odd Z elements) fluxes. The abundance ratio at the source for S/Si is 0.167±0.006, for Ne/Si is 0.833±0.025, for Mg/Si is 0.994±0.029, and for C/O is 0.836±0.025. These values are determined independent of cosmic-ray propagation.
Collapse
|
2
|
Temporal Structures in Electron Spectra and Charge Sign Effects in Galactic Cosmic Rays. PHYSICAL REVIEW LETTERS 2023; 130:161001. [PMID: 37154630 DOI: 10.1103/physrevlett.130.161001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 11/21/2022] [Accepted: 02/09/2023] [Indexed: 05/10/2023]
Abstract
We present the precision measurements of 11 years of daily cosmic electron fluxes in the rigidity interval from 1.00 to 41.9 GV based on 2.0×10^{8} electrons collected with the Alpha Magnetic Spectrometer (AMS) aboard the International Space Station. The electron fluxes exhibit variations on multiple timescales. Recurrent electron flux variations with periods of 27 days, 13.5 days, and 9 days are observed. We find that the electron fluxes show distinctly different time variations from the proton fluxes. Remarkably, a hysteresis between the electron flux and the proton flux is observed with a significance of greater than 6σ at rigidities below 8.5 GV. Furthermore, significant structures in the electron-proton hysteresis are observed corresponding to sharp structures in both fluxes. This continuous daily electron data provide unique input to the understanding of the charge sign dependence of cosmic rays over an 11-year solar cycle.
Collapse
|
3
|
Properties of Daily Helium Fluxes. PHYSICAL REVIEW LETTERS 2022; 128:231102. [PMID: 35749176 DOI: 10.1103/physrevlett.128.231102] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Accepted: 05/06/2022] [Indexed: 06/15/2023]
Abstract
We present the precision measurement of 2824 daily helium fluxes in cosmic rays from May 20, 2011 to October 29, 2019 in the rigidity interval from 1.71 to 100 GV based on 7.6×10^{8} helium nuclei collected with the Alpha Magnetic Spectrometer (AMS) aboard the International Space Station. The helium flux and the helium to proton flux ratio exhibit variations on multiple timescales. In nearly all the time intervals from 2014 to 2018, we observed recurrent helium flux variations with a period of 27 days. Shorter periods of 9 days and 13.5 days are observed in 2016. The strength of all three periodicities changes with time and rigidity. In the entire time period, we found that below ∼7 GV the helium flux exhibits larger time variations than the proton flux, and above ∼7 GV the helium to proton flux ratio is time independent. Remarkably, below 2.4 GV a hysteresis between the helium to proton flux ratio and the helium flux was observed at greater than the 7σ level. This shows that at low rigidity the modulation of the helium to proton flux ratio is different before and after the solar maximum in 2014.
Collapse
|
4
|
Periodicities in the Daily Proton Fluxes from 2011 to 2019 Measured by the Alpha Magnetic Spectrometer on the International Space Station from 1 to 100 GV. PHYSICAL REVIEW LETTERS 2021; 127:271102. [PMID: 35061443 DOI: 10.1103/physrevlett.127.271102] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Revised: 09/24/2021] [Accepted: 11/08/2021] [Indexed: 06/14/2023]
Abstract
We present the precision measurement of the daily proton fluxes in cosmic rays from May 20, 2011 to October 29, 2019 (a total of 2824 days or 114 Bartels rotations) in the rigidity interval from 1 to 100 GV based on 5.5×10^{9} protons collected with the Alpha Magnetic Spectrometer aboard the International Space Station. The proton fluxes exhibit variations on multiple timescales. From 2014 to 2018, we observed recurrent flux variations with a period of 27 days. Shorter periods of 9 days and 13.5 days are observed in 2016. The strength of all three periodicities changes with time and rigidity. The rigidity dependence of the 27-day periodicity is different from the rigidity dependences of 9-day and 13.5-day periods. Unexpectedly, the strength of 9-day and 13.5-day periodicities increases with increasing rigidities up to ∼10 GV and ∼20 GV, respectively. Then the strength of the periodicities decreases with increasing rigidity up to 100 GV.
Collapse
|
5
|
Erratum: Properties of a New Group of Cosmic Nuclei: Results from the Alpha Magnetic Spectrometer on Sodium, Aluminum, and Nitrogen [Phys. Rev. Lett. 127, 021101 (2021)]. PHYSICAL REVIEW LETTERS 2021; 127:159901. [PMID: 34678040 DOI: 10.1103/physrevlett.127.159901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Indexed: 06/13/2023]
Abstract
This corrects the article DOI: 10.1103/PhysRevLett.127.021101.
Collapse
|
6
|
Properties of a New Group of Cosmic Nuclei: Results from the Alpha Magnetic Spectrometer on Sodium, Aluminum, and Nitrogen. PHYSICAL REVIEW LETTERS 2021; 127:021101. [PMID: 34296911 DOI: 10.1103/physrevlett.127.021101] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 04/30/2021] [Accepted: 06/01/2021] [Indexed: 06/13/2023]
Abstract
We report the properties of sodium (Na) and aluminum (Al) cosmic rays in the rigidity range 2.15 GV to 3.0 TV based on 0.46 million sodium and 0.51 million aluminum nuclei collected by the Alpha Magnetic Spectrometer experiment on the International Space Station. We found that Na and Al, together with nitrogen (N), belong to a distinct cosmic ray group. In this group, we observe that, similar to the N flux, both the Na flux and Al flux are well described by the sums of a primary cosmic ray component (proportional to the silicon flux) and a secondary cosmic ray component (proportional to the fluorine flux). The fraction of the primary component increases with rigidity for the N, Na, and Al fluxes and becomes dominant at the highest rigidities. The Na/Si and Al/Si abundance ratios at the source, 0.036±0.003 for Na/Si and 0.103±0.004 for Al/Si, are determined independent of cosmic ray propagation.
Collapse
|
7
|
Properties of Heavy Secondary Fluorine Cosmic Rays: Results from the Alpha Magnetic Spectrometer. PHYSICAL REVIEW LETTERS 2021; 126:081102. [PMID: 33709764 DOI: 10.1103/physrevlett.126.081102] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Accepted: 01/22/2021] [Indexed: 06/12/2023]
Abstract
Precise knowledge of the charge and rigidity dependence of the secondary cosmic ray fluxes and the secondary-to-primary flux ratios is essential in the understanding of cosmic ray propagation. We report the properties of heavy secondary cosmic ray fluorine F in the rigidity R range 2.15 GV to 2.9 TV based on 0.29 million events collected by the Alpha Magnetic Spectrometer experiment on the International Space Station. The fluorine spectrum deviates from a single power law above 200 GV. The heavier secondary-to-primary F/Si flux ratio rigidity dependence is distinctly different from the lighter B/O (or B/C) rigidity dependence. In particular, above 10 GV, the F/Si/B/O ratio can be described by a power law R^{δ} with δ=0.052±0.007. This shows that the propagation properties of heavy cosmic rays, from F to Si, are different from those of light cosmic rays, from He to O, and that the secondary cosmic rays have two classes.
Collapse
|
8
|
Properties of Iron Primary Cosmic Rays: Results from the Alpha Magnetic Spectrometer. PHYSICAL REVIEW LETTERS 2021; 126:041104. [PMID: 33576661 DOI: 10.1103/physrevlett.126.041104] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 11/22/2020] [Accepted: 12/09/2020] [Indexed: 06/12/2023]
Abstract
We report the observation of new properties of primary iron (Fe) cosmic rays in the rigidity range 2.65 GV to 3.0 TV with 0.62×10^{6} iron nuclei collected by the Alpha Magnetic Spectrometer experiment on the International Space Station. Above 80.5 GV the rigidity dependence of the cosmic ray Fe flux is identical to the rigidity dependence of the primary cosmic ray He, C, and O fluxes, with the Fe/O flux ratio being constant at 0.155±0.006. This shows that unexpectedly Fe and He, C, and O belong to the same class of primary cosmic rays which is different from the primary cosmic rays Ne, Mg, and Si class.
Collapse
|
9
|
Relationship between tumor cell infiltration and 5-aminolevulinic acid fluorescence signals after resection of MR-enhancing lesions and its prognostic significance in glioblastoma. Clin Transl Oncol 2020; 23:459-467. [PMID: 32617871 DOI: 10.1007/s12094-020-02438-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 06/19/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE This study investigated the degree of tumor cell infiltration in the tumor cavity and ventricle wall based on fluorescent signals of 5-aminolevulinic acid (5-ALA) after removal of the magnetic resonance (MR)-enhancing area and analyzed its prognostic significance in glioblastoma. METHODS Twenty-five newly developed isocitrate dehydrogenase (IDH)-wildtype glioblastomas with complete resection both of MR-enhancing lesions and strong purple fluorescence on resection cavity were retrospectively analyzed. The fluorescent signals of 5-ALA were divided into strong purple, vague pink, and blue colors. The pathologic findings were classified into massively infiltrating tumor cells, infiltrating tumor cells, suspicious single-cell infiltration, and normal-appearing cells. The pathological findings were analyzed according to the fluorescent signals in the resection cavity and ventricle wall. RESULTS There was no correlation between fluorescent signals and infiltrating tumor cells in the resection cavity (p = 0.199) and ventricle wall (p = 0.704) after resection of the MR-enhancing lesion. The median progression-free survival (PFS) and median overall survival (OS) were 12.5 (± 2.1) and 21.1 (± 3.5) months, respectively. In univariate analysis, the presence of definitive infiltrating tumor cells in the resection cavity and ventricle wall was significantly related to the PFS (p = 0.002) and OS (p = 0.027). In multivariate analysis, the absence of definitive infiltrating tumor cells improved PFS (hazard ratio: 0.184; 95% CI: 0.049-0.690, p = 0.012) and OS (hazard ratio: 0.124; 95% CI: 0.015-0.998, p = 0.050). CONCLUSIONS After resection both of the MR-enhancing lesions and strong purple fluorescence on resection cavity, there was no correlation between remnant fluorescent signals and infiltrating tumor cells. The remnant definitive infiltrating tumor cells in the resection cavity and ventricle wall significantly influenced the prognosis of patients with glioblastoma. Aggressive surgical removal of infiltrating tumor cells may improve their prognosis.
Collapse
|
10
|
Properties of Neon, Magnesium, and Silicon Primary Cosmic Rays Results from the Alpha Magnetic Spectrometer. PHYSICAL REVIEW LETTERS 2020; 124:211102. [PMID: 32530660 DOI: 10.1103/physrevlett.124.211102] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Accepted: 04/20/2020] [Indexed: 06/11/2023]
Abstract
We report the observation of new properties of primary cosmic rays, neon (Ne), magnesium (Mg), and silicon (Si), measured in the rigidity range 2.15 GV to 3.0 TV with 1.8×10^{6} Ne, 2.2×10^{6} Mg, and 1.6×10^{6} Si nuclei collected by the Alpha Magnetic Spectrometer experiment on the International Space Station. The Ne and Mg spectra have identical rigidity dependence above 3.65 GV. The three spectra have identical rigidity dependence above 86.5 GV, deviate from a single power law above 200 GV, and harden in an identical way. Unexpectedly, above 86.5 GV the rigidity dependence of primary cosmic rays Ne, Mg, and Si spectra is different from the rigidity dependence of primary cosmic rays He, C, and O. This shows that the Ne, Mg, and Si and He, C, and O are two different classes of primary cosmic rays.
Collapse
|
11
|
Properties of Cosmic Helium Isotopes Measured by the Alpha Magnetic Spectrometer. PHYSICAL REVIEW LETTERS 2019; 123:181102. [PMID: 31763896 DOI: 10.1103/physrevlett.123.181102] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Revised: 10/02/2019] [Indexed: 06/10/2023]
Abstract
Precision measurements by the Alpha Magnetic Spectrometer (AMS) on the International Space Station of ^{3}He and ^{4}He fluxes are presented. The measurements are based on 100 million ^{4}He nuclei in the rigidity range from 2.1 to 21 GV and 18 million ^{3}He from 1.9 to 15 GV collected from May 2011 to November 2017. We observed that the ^{3}He and ^{4}He fluxes exhibit nearly identical variations with time. The relative magnitude of the variations decreases with increasing rigidity. The rigidity dependence of the ^{3}He/^{4}He flux ratio is measured for the first time. Below 4 GV, the ^{3}He/^{4}He flux ratio was found to have a significant long-term time dependence. Above 4 GV, the ^{3}He/^{4}He flux ratio was found to be time independent, and its rigidity dependence is well described by a single power law ∝R^{Δ} with Δ=-0.294±0.004. Unexpectedly, this value is in agreement with the B/O and B/C spectral indices at high energies.
Collapse
|
12
|
P3715Impact of sleep-disordered breathing on short-term functional outcomes in ischemic stroke patients: a cardiopulmonary coupling analysis using holter-monitoring. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz745.0569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Background
Sleep-disordered breathing (SDB) assessed by conventional polysomnography is reported to have close association with worsened clinical outcomes in patients with ischemic stroke. The cardiopulmonary coupling (CPC) analysis using Holter-monitoring is an easily assessable method to evaluate SDB. However, its prognostic impact needs to be investigated.
Purpose
The present study investigated the prognostic impact of SDB defined by CPC analysis using Holter-monitoring at early stage of ischemic stroke on the functional disability at 3-month follow-up.
Methods
Total 692 patients with acute ischemic stroke who underwent Holter-monitoring were enrolled. The CPC analysis was conducted and SDB was defined as the presence of narrow-band (NB) coupling during sleep time. We investigated the association between SDB and functional disability at 3-month measured by modified Rankin scale (mRS).
Result
The NB coupling was present in 216 (31.2%) of 692 patients with mean age of 64.2±12.8 years. The NB group showed significantly higher proportion of severe functional disability (mRS ≥3; 45.3% vs. 12.3%, p<0.001) and persistent disability (ΔmRS≤0; 42.6% vs. 56.4%, p<0.001) after 3-month. In multivariate analysis, the presence of NB coupling was an independent predictor of higher risk of both severe and persistent functional disability (HR: 3.97; 95% CI: 2.37–6.64; p<0.001; and HR 1.92; 95% CI: 1.34–2.77; p<0.001, respectively). The results were consistent after propensity-score matched analysis with 175 patient pairs (C-statistics=0.759).
Parameters of functional disability Overall population (n=692) PSM population (n=350) no NB (n=476) NB (n=216) OR (95% CI) p-value no NB (n=175) NB (n=175) OR (95% CI) p-value Initial NIHSS ≥5 89 (18.6) 81 (37.5) <0.001 52 (29.7) 52 (29.7) >0.999 Discharge mRS ≥3 146 (30.6) 126 (58.3) <0.001 90 (51.4) 89 (50.8) 0.915 3-month mRS ≥3 59 (12.3) 98 (45.3) 5.86 (4.00–8.60) <0.001 38 (21.7) 72 (41.1) 2.52 (1.57–4.02) <0.001 3-month ΔmRS ≤0 (persisent disability) 203 (42.6) 122 (56.4) 1.74 (1.26–2.41) 0.001 77 (44.0) 100 (57.1) 1.69 (1.11–2.58) 0.014 Data are expressed as n (%). mRS = modified Rankin's scale; NB = narrow-band; NIHSS = National Institutes of Health Stroke Scale; OR = odds ratio; PSM = propensity-score matched.
Functional disabilities after 3-month
Conclusion
SDB assessed by CPC analysis at early phase of ischemic stroke was able to predict both greater and persistent functional disability at 3-month. The CPC analysis using Holter-monitoring is a useful modality for predicting functional disabilities in acute ischemic stroke.
Collapse
|
13
|
P1249Prognostic impact of sarcopenia on major adverse cardiovascular outcomes in coronary artery disease patients undergoing successful percutaneous coronary intervention. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz748.0207] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Background
Sarcopenia is an emerging marker of frailty. Its prognostic impact on atherosclerotic cardiovascular disease (ASCVD) requires further investigation.
Purpose
We investigated the long-term prognostic impact of computed tomography (CT)-determined sarcopenia in patients with coronary artery disease (CAD).
Methods
Total 475 CAD patients those who underwent successful percutaneous coronary intervention (PCI) and performed CT scan within 30 days of PCI were enrolled. The cross-sectional area of skeletal muscle at the first lumbar vertebra (L1) level was measured. Sarcopenia was defined as L1 skeletal muscle index of less than 34.60 cm2/m2 for men and of less than 25.90 cm2/m2 for women. Primary outcome was 3-year all-cause mortality and secondary outcome was 3-year major adverse cardiovascular event (MACE), a composite of all-cause mortality, any myocardial infarction, and repeat revascularization.
Results
Sarcopenia was present in 214 (45.1%) of 475 patients. The incidence of 3-year all-cause mortality and MACE was significantly higher in patients with sarcopenia than in those without sarcopenia (17.7% vs. 5.7%, p<0.001; and 35.0% vs. 11.2%, p<0.001, respectively). In the fully adjusted multivariable analysis, sarcopenia was an independent predictor of higher risk of 3-year all-cause mortality (odds ratio [OR]: 2.98; 95% confidence interval [CI]: 1.35 to 6.58, p=0.007) and MACE (OR: 4.39; 95% CI: 2.49 to 7.73, p<0.001). The results were consistent after propensity-score matched analysis with 100 pairs of study population (C-statistics = 0.868).
Kaplan–Meier analysis of 3-year outcomes Overall population PSM population Sarcopenia (n=214) No sarcopenia (n=261) Log-rank p-value Sarcopenia (n=100) No sarcopenia (n=100) Log-rank p-value All-cause mortality 36 (17.7) 14 (5.7) <0.001 19 (20.0) 7 (7.7) 0.013 Non-fatal MI 12 (6.6) 5 (2.0) 0.021 6 (7.0) 2 (2.3) 0.134 Repeat revascularization 32 (20.3) 14 (6.2) <0.001 17 (23.3) 8 (8.0) 0.027 Total MACEs 68 (35.0) 27 (11.2) <0.001 36 (39.3) 14 (15.4) 0.001 Data are expressed as n (%). MACE = major adverse cardiovascular event; MI = myocardial infarction; PSM = propensity-score matched.
Clinical impact of sarcopenia on CAD
Conclusion
Sarcopenia is a useful predictor of adverse clinical outcomes in patients with CAD undergoing PCI. CT-determined sarcopenia may further aid in risk stratification and decision-making for patients with established ASCVD.
Acknowledgement/Funding
National Research Foundation of Korea (NRF-2016R1A2B3013825), Ministry of Future Creation and Science of Korea (2018K000255)
Collapse
|
14
|
P4339Reference values for cardiorespiratory fitness in healthy Koreans: compared to western nations and nomogram. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz745.0748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Introduction
Cardiorespiratory Fitness (CRF), defined as the integrated ability to properly oxygenate skeletal muscles during physical activity, is associated with a high risk of cardiovascular disease and all-cause mortality. The reference range for CRF may differ among nations, with Asians under-represented in previous data.
Purpose
In this study, we sought to establish reference values of CRF for Asians using a recent Korean cohort.
Methods
We analyzed 2646 healthy Korean adults recently enrolled in the Korea Institute of Sports Science Fitness Standards (KISS FitS) project with estimated maximal oxygen uptake (VO2max) values during treadmill test. Patients with cardiovascular or renal disease, systemic infection, pregnant women and those with orthopedic injuries unable to measure physical fitness were excluded. Age-specific mean VO2max values were compared with those from recent American, Norwegian, Danish cohorts and old Korean data.
Results
Age-specific reference values for healthy Korean adults in this cohort were as shown (Table). We were able to draw a nomogram to predict exercise capacity for a given age and MET value (Figure). When compared to other countries, less CRF reduction by aging was seen in Asians than in other Westerners. When compared to old Korean data from the 1980s, values were similar after adjustment for difference in methods, except for those under 30 years old which were decreased.
Exercise capacity of healthy Korean Men Women Age VO2max (ml/kg/min) N P-value for trend Age VO2max (ml/kg/min) N P-value for trend 19–29 42.3±6.3± 209 <0.01 19–29 34.3±4.3± 110 <0.01 30–39 42.0±5.0± 170 39–39 32.2±4.5± 211 40–49 41.4±5.6± 238 40–49 30.8±4.6± 284 50–59 38.0±5.7± 274 50–59 28.3±4.6± 367 60–69 32.4±6.2± 134 60–69 26.0±5.7± 336 70–79 27.2±5.6± 83 70–79 23.9±4.4± 195 >80 24.1±4.0± 11 >80 21.0±3.7± 24 Total 38.6±7.4± 1119 Total 28.5±5.8 1527 Data are presented as mean ± standard deviation. VO2max, maximal oxygen uptake; N, number.
Nomogram of exercise capacity in Koreans
Conclusions
While there was no significant change in CRF over time in the same ethnic group, there was a clear inter-ethnic difference. CRF should be assessed according to ethnic or national standards, and it is necessary to establish a reference for each nation or ethnicity with periodic updates.
Acknowledgement/Funding
National Sports Promotion Fund of the Korea Sports Promotion Foundation in 2015
Collapse
|
15
|
P5744Sleep-disordered breathing assessed by holter-monitoring is associated to worsened one-year clinical outcomes in ischemic stroke patients: a cardiopulmonary coupling analysis. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz746.0684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Background
Sleep-disorder breathing (SDB) using polysomnography is closely associated to poor functional and clinical outcomes in ischemic stroke patients. The cardiopulmonary coupling analysis using Holter-monitoring (CPC-Holter analysis) is an emerging feasible modality to investigate SDB.
Purpose
We investigated the association between SDB defined by CPC-Holter analysis and one-year clinical outcome in patients with acute ischemic stroke.
Methods
Total 666 patients with acute ischemic stroke who underwent Holter-monitoring were enrolled. The CPC-Holter analysis was conducted and SDB was defined as the presence of narrow-band (NB) coupling during sleep time. Primary outcome was recurrent ischemic stroke, and secondary outcome was major adverse cerebrovascular event (MACE), a composite of recurrent ischemic stroke, transient ischemic attack, and all-cause mortality within one year since discharge.
Result
The NB coupling was present in 205 (30.8%) of 666 patients with mean age of 64.1±12.8 years. The NB group showed significantly higher incidence of both recurrent ischemic stroke (8.3% vs. 1.4%, p<0.001) and MACE (14.9% vs. 3.0%, p<0.001) within one-year. In multivariate analysis, presence of NB coupling remained as an independent predictor of both recurrent ischemic stroke and MACE (HR: 4.81; 95% CI: 1.73–13.4; p=0.003; and HR 4.17; 95% CI: 1.74–10.0; p<0.001, respectively). The results were consistent after propensity-score matched analysis with 164 patient pairs (C-statistics=0.757).
One-year clinical outcomes Overall population (n=666) PSM population (n=328) no NB (=461) NB (n=205) Log-rank p-value OR (95% CI) no NB (n=164) NB (n=164) Log-rank p-value OR (95% CI) Recurrent ischemic stroke 6 (1.4) 14 (8.3) <0.001 5.73 (2.20–14.9) 3 (2.0) 11 (8.1) 0.026 3.85 (1.07–13.8) Transient ischemic attack 3 (0.7) 3 (1.7) 0.275 2 (1.3) 3 (2.1) 0.633 Hemorrhagic stroke 0 (0.0) 2 (1.2) 0.027 0 (0.0) 2 (1.5) 0.148 Total death 3 (0.7) 9 (4.8) 0.001 2 (1.3) 3 (1.9) 0.641 MACEs 12 (3.0) 25 (14.9) <0.001 4.63 (2.06–10.4) 7 (5.2) 17 (13.1) 0.030 2.95 (1.06–8.21) Data are expressed as n (%). CI = confidence interval; MACE = major adverse cardiovascular event; NB = narrow-band; OR = odds ratio.
One-year clinical outcomes
Conclusion
SDB assessed by CPC-Holter analysis at early phase of ischemic stroke is a powerful prognostic marker for predicting one-year adverse clinical outcomes. The CPC analysis using Holter-monitoring is a useful modality and could be easily applied to predict clinical outcomes in acute ischemic stroke patients.
Collapse
|
16
|
P2501Validation of FRIEND and ACSM equations for cardiorespiratory fitness: comparison to direct measurement in male CAD patients. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz748.0830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Introduction
Cardiorespiratory fitness (CRF) is associated with a high risk of cardiovascular disease and all-cause mortality. The regression equation of American College of Sports Medicine (ACSM) was a preferred method for estimating maximal oxygen consumption (VO2max). It is well-known that CRF is overestimated in ACSM equation. Recently, Kokkinos reported more precise equation from the Fitness Registry and the Importance of Exercise National Database (FRIEND). Both equations were made from western healthy people.
Purpose
In this study, we compared VO2max estimated by ACSM and FRIEND equations to VO2max directly measured in male coronary artery disease (CAD) patients.
Methods
We analyzed 103 male CAD patients who underwent percutaneous coronary intervention and who participated in cardiac rehabilitation between June 2015 and December 2018. VO2max was directly measured by the gas exchange analysis during treadmill test with modified Bruce protocol. Exclusive criteria were pulmonary disease, chronic kidney disease on hemodialysis, malignancy, peripheral artery disease, insufficient cardiopulmonary exercise test and orthopedic injuries. Directly measured VO2max were compared to ACSM and FRIEND equations.
Results
Age-specific VO2max values, which were directly measured from male CAD patients, were shown in Table. Smaller CRF difference was shown in FRIEND equation than ACSM equation. Compared to the measured value, CRF estimated by ACSM equation was overestimated by 22%, but the one estimated by FRIEND equation had only 2% gap. Figure presents Bland-Altman plots. ACSM equation had the higher bias (5.52ml/kg/min) compared with FRIEND equation (0.200ml/kg/min).
Comparison table of VO2max estimated by ACSM and FRIEND equations with directly measured VO2max in male CAD patients Age Number VO2max (ml/kg/min) Measured ACSM % predicted FRIEND % predicted 30–39 4 29.5 ± (6.6) 35.7 ± (6.1) 122.3 ± (8.5) 29.1 ± (4.3) 100.1 ± (8.7) 40–49 20 29.1 ± (5.1) 35.7 ± (5.4) 123.6 ± (11.1) 29.1 ± (3.8) 101.2 ± (9.5) 50–59 32 25.6 ± (4.3) 31.5 ± (5.1) 123.8 ± (10.1) 26.2 ± (3.6) 103.2 ± (8.5) 60–69 27 26.0 ± (5.1) 31.1 ± (2.6) 120.5 ± (12.6) 25.9 ± (4.0) 100.8 ± (10.5) 70–79 18 21.2 ± (6.0) 26.8 ± (5.4) 123.2 ± (14.8) 22.8 ± (3.9) 105.2 ± (12.0) >80 2 25.0 ± (10.1) 22.8 ± (2.6) 97 ± (28.9) 19.9 ± (1.9) 85.1 ± (27.0) Total 103 25.7 ± (5.6) 31.4 ± (6.0) 122.2 ± (12.4) 26.1 ± (4.3) 102.1 ± (10.4) Data are presented as mean ± (standard deviation).
Bland-Altman plots
Conclusions
FRIEND equation can estimate CRF more accurately than ACSM equation, even in Asian patients with CAD.
Collapse
|
17
|
4098Reduced skeletal muscle mass is associated to worsened long-term clinical outcomes in patients with coronary artery disease: a quantitative analysis by computed tomography. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz745.0110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Sarcopenia is closely associated to poor clinical outcomes in patients with atherosclerotic cardiovascular disease (ASCVD). However, it is unclear whether the skeletal muscle mass at baseline has quantitative effect on future cardiovascular outcomes.
Purpose
We investigated the quantitative effect of skeletal muscle mass on future cardiovascular outcomes in patients with coronary artery disease (CAD).
Methods
Total 475 patients those who underwent successful percutaneous coronary intervention (PCI) for CAD and performed computed tomography (CT) scan within 30 days of PCI were enrolled. The cross-sectional area of skeletal muscle at the first lumbar vertebra (L1) level was measured. Whole study population was divided into 4 groups according to the sex-specific quartiles of skeletal muscle index (SMI). Primary outcome was all-cause mortality and secondary outcome was major adverse cardiovascular event (MACE) within 3 years of follow-up.
Results
Mean follow-up duration was 4.11±3.02 years and average time period from the date of PCI to CT scan was −3.33±11.72 days. The incidence of 3-year all-cause mortality (23.2% vs. 9.9% vs. 6.6% vs. 4.4%, p<0.001) and MACE (42.9% vs. 24.0% vs. 14.3% vs. 6.2%, p<0.001) was significantly higher in the group of lower quartiles of L1-SMI. In the fully adjusted multivariable analysis, lower quartiles of L1-SMI was an independent predictor of higher risk of all-cause mortality and MACE (lowest vs. highest quartile; OR: 4.90, 95% CI: 1.54 to 15.5, p=0.007; and OR: 12.3, 95% CI: 4.99 to 30.4, p<0.001, respectively).
Results of 3-year clinical outcomes SMI Q1 (n=124) SMI Q2 (n=116) SMI Q3 (n=112) SMI Q4 (n=123) Log-rank p-value All-cause mortality 27 (23.2) 11 (9.9) 7 (6.6) 5 (4.4) <0.001 Non-fatal MI 9 (8.7) 3 (3.0) 2 (2.0) 3 (2.6) 0.038 Repeat revascularization 20 (24.9) 15 (15.2) 7 (7.1) 4 (3.8) <0.001 Total MACEs 47 (42.9) 26 (24.0) 15 (14.3) 7 (6.2) <0.001 Data are expressed as n (%). MACE = major adverse cardiovascular event; MI = myocardial infarction; SMI = skeletal muscle index; Q = quartile.
Impact of reduced skeletal muscle on CAD
Conclusion
Skeletal muscle mass at baseline is a powerful predictor of future adverse clinical outcomes in patients with CAD undergoing successful PCI. Quantitative assessment of skeletal muscle mass at L1 level by CT scan provides prognostic implication for future cardiovascular risk stratification.
Acknowledgement/Funding
National Research Foundation of Korea (NRF-2016R1A2B3013825), Ministry of Future Creation and Science of Korea (2018K000255)
Collapse
|
18
|
P2523Hand grip strength as a predictor of exercise capacity in coronary heart disease. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz748.0852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
A recent study has shown that quadriceps strength can be used to predict the level of exercise capacity in patients with coronary heart disease (CHD). We investigated whether the relationship between muscular strength and exercise capacity is also observed with hand grip strength (HGS). We studied 443 participants (age, 61.8±11.2 y; 77.7% male) who underwent coronary intervention and participated in cardiac rehabilitation between 2015 and 2018. Participants were assessed for grip strength, measured using a Jamar dynamometer. Logistic regression was used to assess the relationship between various clinical measures (HGS, age, sex, etc) with the distance walked on a 6-minute walk test (6MWT) and maximal oxygen uptake (VO2max). HGS was significantly related to distance walked on the 6MWT (r=0.435, p<0.001). It was the only predictor of all exercise capacity categories, and one of the strongest predictors of each exercise capacity category. A HGS of 25.5% of body weight predicted an achievement of a 200 m walk on the 6MWT (positive predictive value = 0.95). However, HGS less than 35.5% of body weight predicted that 500m could not be done in 6 minutes (negative predictive value = 0.97). This trend was also observed in the subgroups in which VO2max was measured. This study demonstrates that HGS is associated with exercise capacity in CHD and can be used to predict the level of exercise capacity. These findings may contribute to setting the recommended level of daily activity as well as the level of cardiac rehabilitation in CHD.
Logistic regression models for different levels of exercise capacity Level of exercise capacity B±S.E p-value Odd ratio 95% CI Distance of 6MWT 200 m Grip strength 0.054±0.014 <0.001 1.056 1.027–1.086 300 m Grip strength 0.042±0.009 <0.001 1.042 1.024–1.062 400 m Grip strength 0.047±0.011 <0.001 1.048 1.026–1.070 500 m Grip strength 0.051±0.016 0.001 1.053 1.021–1.086 VO2max level 4 METs Grip strength 0.054±0.010 <0.001 1.056 1.036–1.076 6 METs Grip strength 0.059±0.011 <0.001 1.061 1.039–1.083 8 METs Grip strength 0.081±0.015 <0.001 1.085 1.053–1.117 10 METs Grip strength 0.113±0.049 0.019 1.12 1.019–3.232 Data are presented as mean ± standard deviation (SD). 6MWT, 6-minute walk test; STEMI, ST-Elevation Myocardial Infarction; SE, standard error; CI, confidence interval; VO2max, Maximal Oxygen uptake; METs, Metabolic equivalents.
Collapse
|
19
|
Observation of Complex Time Structures in the Cosmic-Ray Electron and Positron Fluxes with the Alpha Magnetic Spectrometer on the International Space Station. PHYSICAL REVIEW LETTERS 2018; 121:051102. [PMID: 30118287 DOI: 10.1103/physrevlett.121.051102] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Revised: 05/11/2018] [Indexed: 06/08/2023]
Abstract
We present high-statistics, precision measurements of the detailed time and energy dependence of the primary cosmic-ray electron flux and positron flux over 79 Bartels rotations from May 2011 to May 2017 in the energy range from 1 to 50 GeV. For the first time, the charge-sign dependent modulation during solar maximum has been investigated in detail by leptons alone. Based on 23.5×10^{6} events, we report the observation of short-term structures on the timescale of months coincident in both the electron flux and the positron flux. These structures are not visible in the e^{+}/e^{-} flux ratio. The precision measurements across the solar polarity reversal show that the ratio exhibits a smooth transition over 830±30 days from one value to another. The midpoint of the transition shows an energy dependent delay relative to the reversal and changes by 260±30 days from 1 to 6 GeV.
Collapse
|
20
|
Observation of Fine Time Structures in the Cosmic Proton and Helium Fluxes with the Alpha Magnetic Spectrometer on the International Space Station. PHYSICAL REVIEW LETTERS 2018; 121:051101. [PMID: 30118264 DOI: 10.1103/physrevlett.121.051101] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Revised: 05/09/2018] [Indexed: 06/08/2023]
Abstract
We present the precision measurement from May 2011 to May 2017 (79 Bartels rotations) of the proton fluxes at rigidities from 1 to 60 GV and the helium fluxes from 1.9 to 60 GV based on a total of 1×10^{9} events collected with the Alpha Magnetic Spectrometer aboard the International Space Station. This measurement is in solar cycle 24, which has the solar maximum in April 2014. We observed that, below 40 GV, the proton flux and the helium flux show nearly identical fine structures in both time and relative amplitude. The amplitudes of the flux structures decrease with increasing rigidity and vanish above 40 GV. The amplitudes of the structures are reduced during the time period, which started one year after solar maximum, when the proton and helium fluxes steadily increase. Above ∼3 GV the p/He flux ratio is time independent. We observed that below ∼3 GV the ratio has a long-term decrease coinciding with the period during which the fluxes start to rise.
Collapse
|
21
|
P5534Three-year major clinical outcomes of phosphorylcholine polymer- versus BioLinx polymer-zotarolimus-eluting stents: A propensity score matching study. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy566.p5534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
22
|
119Angiotensin converting enzyme inhibitor versus angiotensin receptor blockers on the top of calcium channel blocker in development of new-onset diabetes mellitus in hypertensive Korean patients. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy564.119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
23
|
P3209Calcium channel blocker monotherapy versus combination with renin-angiotensin system blockers in the development of new-onset diabetes mellitus in hypertensive Korean patients. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy563.p3209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
24
|
|
25
|
P2690The bleeding and cardiovascular risk according to NSAIDs selectivity in patients receiving antithrombotics and concomitant NSAIDs after myocardial infarction: a nationwide cohort study. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy565.p2690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
26
|
Observation of New Properties of Secondary Cosmic Rays Lithium, Beryllium, and Boron by the Alpha Magnetic Spectrometer on the International Space Station. PHYSICAL REVIEW LETTERS 2018; 120:021101. [PMID: 29376729 DOI: 10.1103/physrevlett.120.021101] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Indexed: 06/07/2023]
Abstract
We report on the observation of new properties of secondary cosmic rays Li, Be, and B measured in the rigidity (momentum per unit charge) range 1.9 GV to 3.3 TV with a total of 5.4×10^{6} nuclei collected by AMS during the first five years of operation aboard the International Space Station. The Li and B fluxes have an identical rigidity dependence above 7 GV and all three fluxes have an identical rigidity dependence above 30 GV with the Li/Be flux ratio of 2.0±0.1. The three fluxes deviate from a single power law above 200 GV in an identical way. This behavior of secondary cosmic rays has also been observed in the AMS measurement of primary cosmic rays He, C, and O but the rigidity dependences of primary cosmic rays and of secondary cosmic rays are distinctly different. In particular, above 200 GV, the secondary cosmic rays harden more than the primary cosmic rays.
Collapse
|
27
|
Observation of the Identical Rigidity Dependence of He, C, and O Cosmic Rays at High Rigidities by the Alpha Magnetic Spectrometer on the International Space Station. PHYSICAL REVIEW LETTERS 2017; 119:251101. [PMID: 29303302 DOI: 10.1103/physrevlett.119.251101] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Indexed: 06/07/2023]
Abstract
We report the observation of new properties of primary cosmic rays He, C, and O measured in the rigidity (momentum/charge) range 2 GV to 3 TV with 90×10^{6} helium, 8.4×10^{6} carbon, and 7.0×10^{6} oxygen nuclei collected by the Alpha Magnetic Spectrometer (AMS) during the first five years of operation. Above 60 GV, these three spectra have identical rigidity dependence. They all deviate from a single power law above 200 GV and harden in an identical way.
Collapse
|
28
|
Lunate morphology as a risk factor of idiopathic ulnar impaction syndrome. Bone Joint J 2017; 99-B:1508-1514. [PMID: 29092991 DOI: 10.1302/0301-620x.99b11.bjj-2016-1238.r2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2016] [Accepted: 05/15/2017] [Indexed: 02/06/2023]
Abstract
AIMS Positive ulnar variance is an established risk factor for idiopathic ulnar impaction syndrome (UIS). However, not all patients with positive ulnar variance develop symptomatic UIS and other factors, including the morphology of the lunate, may be involved. The aim of this study was to clarify the relationship between lunate morphology and idiopathic UIS. PATIENTS AND METHODS A cohort of 95 patients with idiopathic UIS (UIS group) was compared with 95 asymptomatic controls with positive ulnar variance. The shape of the lunate was measured using the capitate-triquetrum distance (CTD), ulnar coverage ratio (UCR), radiolunate distance and radiolunate angle. The association of radiographic parameters and lunate types with the development of UIS was investigated in univariable and multivariable analyses. Receiver operating characteristic curves were used to estimate a cutoff for any statistically significant variables. RESULTS The proportion of type II lunates, which have a medial hamate facet, were significantly higher in the UIS group than in the control group in the univariable analysis (p = 0.001). CTD (odds ratio (OR) 1.52; 95% confidence interval (CI) 1.11 to 2.06; p = 0.008) and UCR (OR 44.78; 95% CI 5.35 to 374.90; p = 0.002) showed a positive association with UIS in the multivariable analysis. Estimated cutoff values were 2.5 mm for the CTD (area under the curve (AUC) = 0.65) and 0.4 for the UCR (AUC = 0.64). CONCLUSION The proportion of type II lunates was greater in the UIS group than in the control group. A large UCR, which represents the broad base of the lunate, was positively associated with the development of idiopathic UIS. Cite this article: Bone Joint J 2017;99-B:1508-14.
Collapse
|
29
|
Precision Measurement of the Boron to Carbon Flux Ratio in Cosmic Rays from 1.9 GV to 2.6 TV with the Alpha Magnetic Spectrometer on the International Space Station. PHYSICAL REVIEW LETTERS 2016; 117:231102. [PMID: 27982618 DOI: 10.1103/physrevlett.117.231102] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Indexed: 06/06/2023]
Abstract
Knowledge of the rigidity dependence of the boron to carbon flux ratio (B/C) is important in understanding the propagation of cosmic rays. The precise measurement of the B/C ratio from 1.9 GV to 2.6 TV, based on 2.3 million boron and 8.3 million carbon nuclei collected by AMS during the first 5 years of operation, is presented. The detailed variation with rigidity of the B/C spectral index is reported for the first time. The B/C ratio does not show any significant structures in contrast to many cosmic ray models that require such structures at high rigidities. Remarkably, above 65 GV, the B/C ratio is well described by a single power law R^{Δ} with index Δ=-0.333±0.014(fit)±0.005(syst), in good agreement with the Kolmogorov theory of turbulence which predicts Δ=-1/3 asymptotically.
Collapse
|
30
|
Antiproton Flux, Antiproton-to-Proton Flux Ratio, and Properties of Elementary Particle Fluxes in Primary Cosmic Rays Measured with the Alpha Magnetic Spectrometer on the International Space Station. PHYSICAL REVIEW LETTERS 2016; 117:091103. [PMID: 27610839 DOI: 10.1103/physrevlett.117.091103] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2016] [Indexed: 06/06/2023]
Abstract
A precision measurement by AMS of the antiproton flux and the antiproton-to-proton flux ratio in primary cosmic rays in the absolute rigidity range from 1 to 450 GV is presented based on 3.49×10^{5} antiproton events and 2.42×10^{9} proton events. The fluxes and flux ratios of charged elementary particles in cosmic rays are also presented. In the absolute rigidity range ∼60 to ∼500 GV, the antiproton p[over ¯], proton p, and positron e^{+} fluxes are found to have nearly identical rigidity dependence and the electron e^{-} flux exhibits a different rigidity dependence. Below 60 GV, the (p[over ¯]/p), (p[over ¯]/e^{+}), and (p/e^{+}) flux ratios each reaches a maximum. From ∼60 to ∼500 GV, the (p[over ¯]/p), (p[over ¯]/e^{+}), and (p/e^{+}) flux ratios show no rigidity dependence. These are new observations of the properties of elementary particles in the cosmos.
Collapse
|
31
|
Precision Measurement of the Helium Flux in Primary Cosmic Rays of Rigidities 1.9 GV to 3 TV with the Alpha Magnetic Spectrometer on the International Space Station. PHYSICAL REVIEW LETTERS 2015; 115:211101. [PMID: 26636836 DOI: 10.1103/physrevlett.115.211101] [Citation(s) in RCA: 81] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Indexed: 06/05/2023]
Abstract
Knowledge of the precise rigidity dependence of the helium flux is important in understanding the origin, acceleration, and propagation of cosmic rays. A precise measurement of the helium flux in primary cosmic rays with rigidity (momentum/charge) from 1.9 GV to 3 TV based on 50 million events is presented and compared to the proton flux. The detailed variation with rigidity of the helium flux spectral index is presented for the first time. The spectral index progressively hardens at rigidities larger than 100 GV. The rigidity dependence of the helium flux spectral index is similar to that of the proton spectral index though the magnitudes are different. Remarkably, the spectral index of the proton to helium flux ratio increases with rigidity up to 45 GV and then becomes constant; the flux ratio above 45 GV is well described by a single power law.
Collapse
|
32
|
Precision Measurement of the Proton Flux in Primary Cosmic Rays from Rigidity 1 GV to 1.8 TV with the Alpha Magnetic Spectrometer on the International Space Station. PHYSICAL REVIEW LETTERS 2015; 114:171103. [PMID: 25978222 DOI: 10.1103/physrevlett.114.171103] [Citation(s) in RCA: 129] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2015] [Indexed: 06/04/2023]
Abstract
A precise measurement of the proton flux in primary cosmic rays with rigidity (momentum/charge) from 1 GV to 1.8 TV is presented based on 300 million events. Knowledge of the rigidity dependence of the proton flux is important in understanding the origin, acceleration, and propagation of cosmic rays. We present the detailed variation with rigidity of the flux spectral index for the first time. The spectral index progressively hardens at high rigidities.
Collapse
|
33
|
Precision Measurement of the (e^{+}+e^{-}) Flux in Primary Cosmic Rays from 0.5 GeV to 1 TeV with the Alpha Magnetic Spectrometer on the International Space Station. PHYSICAL REVIEW LETTERS 2014; 113:221102. [PMID: 25494065 DOI: 10.1103/physrevlett.113.221102] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2014] [Indexed: 06/04/2023]
Abstract
We present a measurement of the cosmic ray (e^{+}+e^{-}) flux in the range 0.5 GeV to 1 TeV based on the analysis of 10.6 million (e^{+}+e^{-}) events collected by AMS. The statistics and the resolution of AMS provide a precision measurement of the flux. The flux is smooth and reveals new and distinct information. Above 30.2 GeV, the flux can be described by a single power law with a spectral index γ=-3.170±0.008(stat+syst)±0.008(energy scale).
Collapse
|
34
|
Electron and positron fluxes in primary cosmic rays measured with the alpha magnetic spectrometer on the international space station. PHYSICAL REVIEW LETTERS 2014; 113:121102. [PMID: 25279617 DOI: 10.1103/physrevlett.113.121102] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2014] [Indexed: 06/03/2023]
Abstract
Precision measurements by the Alpha Magnetic Spectrometer on the International Space Station of the primary cosmic-ray electron flux in the range 0.5 to 700 GeV and the positron flux in the range 0.5 to 500 GeV are presented. The electron flux and the positron flux each require a description beyond a single power-law spectrum. Both the electron flux and the positron flux change their behavior at ∼30 GeV but the fluxes are significantly different in their magnitude and energy dependence. Between 20 and 200 GeV the positron spectral index is significantly harder than the electron spectral index. The determination of the differing behavior of the spectral indices versus energy is a new observation and provides important information on the origins of cosmic-ray electrons and positrons.
Collapse
|
35
|
High statistics measurement of the positron fraction in primary cosmic rays of 0.5-500 GeV with the alpha magnetic spectrometer on the international space station. PHYSICAL REVIEW LETTERS 2014; 113:121101. [PMID: 25279616 DOI: 10.1103/physrevlett.113.121101] [Citation(s) in RCA: 76] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2014] [Indexed: 06/03/2023]
Abstract
A precision measurement by AMS of the positron fraction in primary cosmic rays in the energy range from 0.5 to 500 GeV based on 10.9 million positron and electron events is presented. This measurement extends the energy range of our previous observation and increases its precision. The new results show, for the first time, that above ∼200 GeV the positron fraction no longer exhibits an increase with energy.
Collapse
|
36
|
First result from the Alpha Magnetic Spectrometer on the International Space Station: precision measurement of the positron fraction in primary cosmic rays of 0.5-350 GeV. PHYSICAL REVIEW LETTERS 2013; 110:141102. [PMID: 25166975 DOI: 10.1103/physrevlett.110.141102] [Citation(s) in RCA: 123] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2013] [Indexed: 06/03/2023]
Abstract
A precision measurement by the Alpha Magnetic Spectrometer on the International Space Station of the positron fraction in primary cosmic rays in the energy range from 0.5 to 350 GeV based on 6.8 × 10(6) positron and electron events is presented. The very accurate data show that the positron fraction is steadily increasing from 10 to ∼ 250 GeV, but, from 20 to 250 GeV, the slope decreases by an order of magnitude. The positron fraction spectrum shows no fine structure, and the positron to electron ratio shows no observable anisotropy. Together, these features show the existence of new physical phenomena.
Collapse
|
37
|
Pump efficiency improvement of a C-band tunable fiber laser using optical circulator and tunable fiber gratings. APPLIED OPTICS 2007; 46:2280-5. [PMID: 17415397 DOI: 10.1364/ao.46.002280] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
We propose and demonstrate a tunable fiber laser based on an optical circulator (OC) and two tunable fiber Bragg gratings (TFBGs). The OC acts as a pump power router to improve the pumping efficiency, and a 4% increase in overall conversion efficiency has been observed. The combined tuning spectra range of two TFBGs could cover the entire C-band spectrum from 1530 to 1560 nm. Stable laser output power above 10 dBm is obtained using 1.9 m of erbium-doped fiber and TFBGs with 50% reflectivity. With power equalization by using variable optical attenuators, the power variation is less than 0.1 dB in the whole C band with narrow linewidth of 0.05 nm. A signal-to-noise ratio of 60 dB and a continuous tuning resolution of 0.5 nm have been achieved. The TFBG-based tunable fiber laser can be a promising light source for WDM transmission and fiber sensor applications.
Collapse
|
38
|
Evidence for a long-range component in the pion emission source in Au+Au collisions at sqrt sNN=200 GeV. PHYSICAL REVIEW LETTERS 2007; 98:132301. [PMID: 17501193 DOI: 10.1103/physrevlett.98.132301] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2006] [Indexed: 05/15/2023]
Abstract
Emission source functions are extracted from correlation functions constructed from charged pions produced at midrapidity in Au+Au collisions at sqrt[s(NN)]=200 GeV. The source parameters extracted from these functions at low k(T) give first indications of a long tail for the pion emission source. The source extension cannot be explained solely by simple kinematic considerations. The possible role of a halo of secondary pions from resonance emissions is explored.
Collapse
|
39
|
Dense-medium modifications to jet-induced hadron pair distributions in Au+Au collisions at sqrt s NN=200 GeV. PHYSICAL REVIEW LETTERS 2006; 97:052301. [PMID: 17026095 DOI: 10.1103/physrevlett.97.052301] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2005] [Indexed: 05/12/2023]
Abstract
Azimuthal correlations of jet-induced high-p(T) charged hadron pairs are studied at midrapidity in Au+Au collisions at sqrt[s(NN)]=200 GeV. The distribution of jet-associated partner hadrons (1.0<p(T)<2.5 GeV/c) per trigger hadron (2.5<p(T)<4.0 GeV/c) is found to vary with collision centrality, in both shape and yield, indicating a significant effect of the nuclear collision medium on the jet fragmentation process.
Collapse
|
40
|
Common suppression pattern of eta and pi0 mesons at high transverse momentum in Au + Au collisions at square root S(NN) = 200 GeV. PHYSICAL REVIEW LETTERS 2006; 96:202301. [PMID: 16803168 DOI: 10.1103/physrevlett.96.202301] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2006] [Indexed: 05/10/2023]
Abstract
Inclusive transverse momentum spectra of eta mesons have been measured within p(T) = 2-10 GeV/c at midrapidity by the PHENIX experiment in Au + Au collisions at square root S(NN) = 200 GeV. In central Au+Au the eta yields are significantly suppressed compared to peripheral Au + Au, d + Au, and p + p yields scaled by the corresponding number of nucleon-nucleon collisions. The magnitude, centrality, and p(T) dependence of the suppression is common, within errors, for eta and pi0. The ratio of eta to pi0 spectra at high p(T) amounts to 0.40 < R(eta/pi)0 < 0.48 for the three systems, in agreement with the world average measured in hadronic and nuclear reactions and, at large scaled momentum, in e+e- collisions.
Collapse
|
41
|
Single electrons from heavy-flavor decays in collisions at. PHYSICAL REVIEW LETTERS 2006; 96:032001. [PMID: 16486684 DOI: 10.1103/physrevlett.96.032001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2005] [Indexed: 05/06/2023]
Abstract
The invariant differential cross section for inclusive electron production in p+p collisions at [FORMULA: SEE TEXT] has been measured by the PHENIX experiment at the BNL Relativistic Heavy Ion Collider over the transverse momentum range 0.4<or=pT<OR=5.0 GeV/c in the central rapidity region ([FORMULA: SEE TEXT]). The contribution to the inclusive electron spectrum from semileptonic decays of hadrons carrying heavy flavor, i.e., charm quarks or, at high , bottom quarks, is determined via three independent methods. The resulting electron spectrum from heavy-flavor decays is compared to recent leading and next-to-leading order perturbative QCD calculations. The total cross section of charm quark-antiquark pair production is determined to be [FORMULA: SEE TEXT].
Collapse
|
42
|
Measurement of identified and inclusive photon second-harmonic parameter and implications for direct photon production in [FORMULA: SEE TEXT] Au+Au. PHYSICAL REVIEW LETTERS 2006; 96:032302. [PMID: 16486688 DOI: 10.1103/physrevlett.96.032302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2005] [Indexed: 05/06/2023]
Abstract
The azimuthal distribution of identified pi0 and inclusive photons has been measured in [FORMULA: SEE TEXT] Au+Au collisions with the PHENIX experiment at the Relativistic Heavy-Ion Collider (RHIC). The second-harmonic parameter (nu2) was measured to describe the observed anisotropy of the azimuthal distribution. The measured inclusive photon is consistent with the value expected for the photons from hadron decay and is also consistent with the lack of direct photon signal over the measured pT range 1-6 GeV/c. An attempt is made to extract nu2 of direct photons.
Collapse
|
43
|
Nuclear modification of electron spectra and implications for heavy quark energy loss in Au+Au collisions at [FORMULA: SEE TEXT]. PHYSICAL REVIEW LETTERS 2006; 96:032301. [PMID: 16486687 DOI: 10.1103/physrevlett.96.032301] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2005] [Indexed: 05/06/2023]
Abstract
The PHENIX experiment has measured midrapidity ([FORMULA: SEE TEXT]) transverse momentum spectra ([FORMULA: SEE TEXT]) of electrons as a function of centrality in Au+Au collisions at [FORMULA: SEE TEXT]. Contributions from photon conversions and from light hadron decays, mainly Dalitz decays of pi0 and eta mesons, were removed. The resulting nonphotonic electron spectra are primarily due to the semileptonic decays of hadrons carrying heavy quarks. Nuclear modification factors were determined by comparison to nonphotonic electrons in p+p collisions. A significant suppression of electrons at high pT is observed in central Au+Au collisions, indicating substantial energy loss of heavy quarks.
Collapse
|
44
|
Measurement of transverse single-spin asymmetries for midrapidity production of neutral pions and charged hadrons in polarized p + p collisions at square root(s) = 200 GeV. PHYSICAL REVIEW LETTERS 2005; 95:202001. [PMID: 16384048 DOI: 10.1103/physrevlett.95.202001] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2005] [Indexed: 05/05/2023]
Abstract
Transverse single-spin asymmetries to probe the transverse-spin structure of the proton have been measured for neutral pions and nonidentified charged hadrons from polarized proton-proton collisions at midrapidity and square root(s) = 200 GeV. The data cover a transverse momentum (pT) range 1.0-5.0 GeV/c for neutral pions and 0.5-5.0 GeV/c for charged hadrons, at a Feynman-x value of approximately zero. The asymmetries seen in this previously unexplored kinematic region are consistent with zero within errors of a few percent. In addition, the inclusive charged hadron cross section at midrapidity from 0.5 < pT < 7.0 GeV/c is presented and compared to next-to-leading order perturbative QCD (pQCD) calculations. Successful description of the unpolarized cross section above approximately 2 GeV/c suggests that pQCD is applicable in the interpretation of the asymmetry results in the relevant kinematic range.
Collapse
|
45
|
Saturation of azimuthal anisotropy in Au + Au collisions at (square root)s(NN) = 62-200 GeV. PHYSICAL REVIEW LETTERS 2005; 94:232302. [PMID: 16090463 DOI: 10.1103/physrevlett.94.232302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2004] [Indexed: 05/03/2023]
Abstract
New measurements are presented for charged hadron azimuthal correlations at midrapidity in Au+Au collisions at (square root)s(NN) = 62.4 and 200 GeV. They are compared to earlier measurements obtained at (square root)s(NN) = 130 GeV and in Pb + Pb collisions at (square root)s(NN) = 17.2 GeV. Sizeable anisotropies are observed with centrality and transverse momentum (pT) dependence characteristic of elliptic flow (upsilon2). For a broad range of centralities, the observed magnitudes and trends of the differential anisotropy, upsilon2(pT), change very little over the collision energy range (square root)s(NN) = 62-200 GeV, indicating saturation of the excitation function for upsilon2 at these energies. Such a saturation may be indicative of the dominance of a very soft equation of state for (square root)s(NN) approximately 60-200 GeV.
Collapse
|
46
|
Centrality dependence of direct photon production in (square root)S(NN) = 200 GeV Au + Au collisions. PHYSICAL REVIEW LETTERS 2005; 94:232301. [PMID: 16090462 DOI: 10.1103/physrevlett.94.232301] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2005] [Indexed: 05/03/2023]
Abstract
The first measurement of direct photons in Au + Au collisions at (square root)S(NN) = 200 GeV is presented. The direct photon signal is extracted as a function of the Au + Au collision centrality and compared to next-to-leading order perturbative quantum chromodynamics calculations. The direct photon yield is shown to scale with the number of nucleon-nucleon collisions for all centralities.
Collapse
|
47
|
Deuteron and antideuteron production in Au+Au collisions at square root of s(NN)=200 GeV. PHYSICAL REVIEW LETTERS 2005; 94:122302. [PMID: 15903909 DOI: 10.1103/physrevlett.94.122302] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2004] [Indexed: 05/02/2023]
Abstract
The production of deuterons and antideuterons in the transverse momentum range 1.1<p(T)<4.3 GeV/c at midrapidity in Au+Au collisions at square root of s(NN)=200 GeV has been studied by the PHENIX experiment at RHIC. A coalescence analysis, comparing the deuteron and antideuteron spectra with that of proton and antiproton, has been performed. The coalescence probability is equal for both deuterons and antideuterons and it increases as a function of p(T), which is consistent with an expanding collision zone. Comparing (anti)proton yields, p /p=0.73+/-0.01, with (anti)deuteron yields, d /d=0.47+/-0.03, we estimate that n /n=0.64+/-0.04. The nucleon phase space density is estimated from the coalescence measurement.
Collapse
|
48
|
Centrality dependence of charm production from a measurement of single electrons in Au+Au collisions at sqrt[s(NN)]=200 GeV. PHYSICAL REVIEW LETTERS 2005; 94:082301. [PMID: 15783878 DOI: 10.1103/physrevlett.94.082301] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2004] [Indexed: 05/24/2023]
Abstract
The PHENIX experiment has measured midrapidity transverse momentum spectra (0.4<p(T)<4.0 GeV/c) of single electrons as a function of centrality in Au+Au collisions at sqrt[s(NN)]=200 GeV. Contributions from photon conversions and Dalitz decays of light neutral mesons are measured by introducing a thin (1.7% X0) converter into the PHENIX acceptance and are statistically removed. The subtracted nonphotonic electron spectra are primarily due to the semileptonic decays of hadrons containing heavy quarks, mainly charm at lower p(T). For all centralities, the charm production cross section is found to scale with the nuclear overlap function, T(AA). For minimum-bias collisions the charm cross section per binary collision is N(cc )/T(AA)=622+/-57(stat)+/-160(syst) microb.
Collapse
|
49
|
Bose-Einstein correlations of charged pion pairs in Au + Au collisions at square root sNN = 200 GeV. PHYSICAL REVIEW LETTERS 2004; 93:152302. [PMID: 15524868 DOI: 10.1103/physrevlett.93.152302] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2004] [Indexed: 05/24/2023]
Abstract
Bose-Einstein correlations of identically charged pion pairs were measured by the PHENIX experiment at midrapidity in Au + Au collisions at square root s(NN)=200 GeV. The Bertsch-Pratt radius parameters were determined as a function of the transverse momentum of the pair and as a function of the centrality of the collision. Using the standard core-halo partial Coulomb fits, and a new parametrization which constrains the Coulomb fraction as determined from the unlike-sign pion correlation, the ratio R(out)/R(side) is within 0.8-1.1 for 0.25< <k(T)> <1.2 GeV/c. The centrality dependence of all radii is well described by a linear scaling in N(1/3)(part), and R(out)/R(side) for <k(T)> approximately 0.45 GeV/c is approximately constant at unity as a function of centrality.
Collapse
|
50
|
Measurement of nonrandom event-by-event fluctuations of average transverse momentum in square root of (sNN)=200 GeV Au+Au and p+p collisions. PHYSICAL REVIEW LETTERS 2004; 93:092301. [PMID: 15447093 DOI: 10.1103/physrevlett.93.092301] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2003] [Indexed: 05/24/2023]
Abstract
Event-by-event fluctuations of the average transverse momentum of produced particles near midrapidity have been measured by the PHENIX Collaboration in square root of (sNN)=200 GeV Au+Au, and p+p collisions at the Relativistic Heavy Ion Collider. The fluctuations are observed to be in excess of the expectation for statistically independent particle emission for all centralities. The excess fluctuations exhibit a dependence on both the centrality of the collision and on the pT range over which the average is calculated. Both the centrality and pT dependence can be well reproduced by a simulation of random particle production with the addition of contributions from hard-scattering processes.
Collapse
|