How Are High-Voltage Devices Used for Primary Prevention in Very Elderly Patients? Circ J 2024:CJ-24-0310. [PMID: 38763734 DOI: 10.1253/circj.cj-24-0310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/21/2024]
|
2
|
Unusual atrial pacing induced by type II far-field p-wave sensing in a patient with complete atrioventricular block. Pacing Clin Electrophysiol 2024; 47:433-436. [PMID: 37221929 DOI: 10.1111/pace.14743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 05/13/2023] [Accepted: 05/16/2023] [Indexed: 05/25/2023]
Abstract
An 88-year-old Japanese woman underwent DDD pacemaker (MicroPort KORA 250 DR, V lead: VEGA R52) implantation for complete atrioventricular block. A 12-lead electrocardiogram for a routine examination showed atrial pacing within the intrinsic P wave, followed by inhibition of ventricular pacing. Pacemaker interrogation revealed no abnormalities in the basic parameters; however, ventricular pacing was inhibited by far-field sensing of intrinsic atrial waves before atrial events; type II far-field P-wave sensing. As a result, unusual atrial pacing occurred due to the pause suppression algorithm, which is the one of the functions that prevent atrial fibrillation development.
Collapse
|
3
|
Spatiotemporal incremental change of radiofrequency catheter ablation-associated pulmonary vein calcifications. J Arrhythm 2023; 39:956-959. [PMID: 38045463 PMCID: PMC10692840 DOI: 10.1002/joa3.12925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 07/31/2023] [Accepted: 09/03/2023] [Indexed: 12/05/2023] Open
Abstract
We presented a detailed time course of RFCA-associated PV calcification process. Because RFCA-associated PV calcification may progress over time even with a single ablation, long-term caution should be paid in cases of especially extensive ablation and/or patients with stiff LA syndrome.
Collapse
|
4
|
Validation of the Implantable Cardioverter-Defibrillators Indication Criteria for Nonischemic Cardiomyopathy - Why? When? How? Circ J 2022; 87:101-102. [PMID: 36070963 DOI: 10.1253/circj.cj-22-0478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
5
|
A survey of the implementation rate of cardiac rehabilitation for patients with heart disease undergoing device implantation in Japan. J Arrhythm 2022; 38:1049-1055. [DOI: 10.1002/joa3.12792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 09/26/2022] [Accepted: 10/15/2022] [Indexed: 11/07/2022] Open
|
6
|
Qualitative study of barriers and facilitators encountered by individuals with physical diseases in returning and continuing to work. BMC Health Serv Res 2022; 22:1229. [PMID: 36192749 PMCID: PMC9531482 DOI: 10.1186/s12913-022-08604-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Accepted: 09/26/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The number of employees with physical diseases is increasing, and there is a need for support to help them return and continue to work. To provide effective support, it is important to identify barriers and facilitators for individuals in returning and continuing to work. Previous studies have reported barriers and facilitators for specific diseases. However, few reports have dealt with these issues across various diseases. To identify a range of barriers and facilitators that may apply to different physical diseases, we conducted a qualitative analysis by interviewing patients with diverse characteristics being treated for diseases. METHODS We conducted semi-structured interviews based on the criteria for qualitative research. We investigated three disease groups to obtain details of barriers and facilitators: impairments that were visible to other people (mainly stroke); impairments invisible to others (mainly heart disease); and impairments that changed over time (mainly cancer). Interview transcripts were analyzed and the results reported using systematic text condensation. RESULTS We extracted 769 meaning units from 28 patient interviews. We categorized barriers and facilitators that were generalizable to various diseases into three themes (personal factors, workplace factors, and inter-sectoral collaboration and social resources) and 10 sub-themes (work ability, psychological impacts, health literacy, social status, family background, workplace structure, workplace system, workplace support, inter-sectoral collaboration, and social resources). CONCLUSIONS This study identified 10 sub-themes that can be applied for workers with physical diseases; those sub-themes may be used as a basis for communicating with those individuals about returning and continuing to work. Our results suggest that various barriers and facilitators for workers with physical diseases should be understood and addressed at medical institutions, workplaces, and support sites.
Collapse
|
7
|
Relationship between Effective Refractory Period and Inducibility of Atrial Fibrillation from the Superior Vena Cava after Pulmonary Vein Isolation. Int Heart J 2022; 63:498-503. [DOI: 10.1536/ihj.21-803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
8
|
Influence of the right ventricular septum/free-wall boundary (hinge) on differentiation of the ventricular lead implantation site. J Cardiol 2022; 80:332-338. [PMID: 35637122 DOI: 10.1016/j.jjcc.2022.05.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Revised: 04/30/2022] [Accepted: 05/06/2022] [Indexed: 11/28/2022]
Abstract
BACKGROUND The prognosis associated with right ventricular (RV) free-wall pacing is worse than that of septal pacing. Identification of the pacing site using a 12‑lead electrocardiogram (ECG) is controversial and may be influenced by ECG changes within the same septal or free-wall area. The relationship between the diagnostic capabilities of ECG and pacing sites has previously been qualitatively evaluated. However, in this study, this relationship was analyzed quantitatively, and accurate evaluation of the pacing site was determined using computed tomography (CT). METHODS Of 779 consecutive outpatients, 65 who underwent pacemaker implantation and thoracic CT were prospectively included and classified into the following groups according to the lead tip position: free-wall, septal, or septum/free-wall boundary (hinge) group. The hinge was used as an anatomical marker, and the distance from the hinge to the lead tip was measured. Under RV pacing, a 12‑lead ECG was obtained. ECG findings were evaluated using three criteria (including lead I, II, and aVL and precordial leads V5 and V6) previously reported to be useful in differentiating pacing sites. RESULTS The lead tips were anchored at the free-wall in 10 patients, the septal wall in 19 patients, and the hinge in 32 patients. Paced QRS duration correlated with the distance from the hinge to the lead tip for the free-wall and septum (r = 0.47 and - 0.68, respectively). Estimation of the lead tip implantation site using the ECG algorithm was useful; however, the algorithm's accuracy decreased around the hinge. CONCLUSIONS ECG is useful in differentiating pacing sites but is less accurate around the hinge, which may be the reason that the identification of the RV pacing site using ECG remains controversial.
Collapse
|
9
|
“Carryover phenomenon” in subcutaneous implantable cardioverter‐defibrillator: Residual energy caused early shock to subsequent ventricular tachycardia. J Arrhythm 2022; 38:482-485. [PMID: 35785396 PMCID: PMC9237301 DOI: 10.1002/joa3.12715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 02/14/2022] [Accepted: 03/28/2022] [Indexed: 11/12/2022] Open
|
10
|
Relationship between device displacement distance toward the caudal side during standing and pocket position laterality. Pacing Clin Electrophysiol 2022; 45:297-301. [PMID: 35172014 DOI: 10.1111/pace.14464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 11/23/2021] [Accepted: 01/23/2022] [Indexed: 11/30/2022]
Abstract
BACKGROUND The displacement of cardiac implantable electronic devices (CIEDs) toward the caudal side during standing after CIED implantation could cause lead dislodgement. This study investigated the relationship between supine pocket position and standing CIEDs' displacement distance after the implantation. METHODS After CIED surgeries performed at 2 hospitals between 2012 and 2020, 134 patients underwent postoperative chest x-rays in the supine and standing positions during hospitalization. To measure the displacement distance of CIEDs from the supine to the standing position, we identified the first thoracic vertebrae (Th1) in the supine position using the first rib as an index, drew a horizontal line at the lower edge of the Th1, and calculated the distance from that point to the upper edge of the CIED. The difference between measures for the two positions was compared. At the position of the pocket in the thorax in the supine position, the ratio of the distance between the thorax and the device is defined as the device thorax ratio (DTR). We examined the relationship between DTR and CIED displacement distance. RESULTS In this study, we included 134 patients (53% men; median age, 79 years, body mass index, 22.3 ± 3.4; pacemaker 93%, left implantation 96%). We found that the more lateral the position of the CIED pocket, the more the CIED fell when standing (confidence interval = 0.34-0.60, P < 0.001). CONCLUSIONS The farther the CIED was implanted outside the thorax in the supine position, the more significantly the CIED was displaced in the standing position. This article is protected by copyright. All rights reserved.
Collapse
|
11
|
Incidence of out-of-hospital cardiac arrests and survival rates after 1 month among the Japanese working population: a cohort study. BMJ Open 2021; 11:e047932. [PMID: 34872993 PMCID: PMC8650304 DOI: 10.1136/bmjopen-2020-047932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
OBJECTIVES The prevention and improvement of the prognosis of out-of-hospital cardiac arrests (OHCAs) are important issues especially with respect to their social and economic significance in working populations. The age distribution of the working population in Japan is expected to change continually due to its ageing society and extension of retirement; however, few reports have examined the long-term condition of OHCA in the working population, defined by age. The aim of this study was to determine the incidence of OHCAs and the survival rates after 1 month, among the Japanese working population, defined by age, considering the changing age distribution. DESIGN AND SETTING We analysed the All-Japan Utstein registry, a prospective, nationwide, population-based, observational registry (2005-2016). PARTICIPANTS From the registry, 212 961 patients with OHCA from the Japanese working population (defined aged 20-69 years), with only cardiogenic aetiology participated in this study. These patients were further divided into four groups according to the type of citizen bystander (family, friends, work-colleagues and passers-by). PRIMARY AND SECONDARY OUTCOME MEASURES The main outcomes were 1-month survival with favourable neurological outcomes. RESULTS The incidence of OHCAs, in any age group, was almost constant during the 12-year period. The work-colleagues had the best prognosis despite having significantly longer times to initial defibrillations compared with the passers-by (13 vs 12 min, respectively, p<0.001) that was associated independently with 1-month survival with favourable neurological outcomes (adjusted OR: 0.94 (1 min increments), p<0.001). CONCLUSIONS In the 12-year period, the incidence of OHCAs in any age group remained almost constant, whereas the prognosis improved each year. Reducing the time to initial defibrillation may further improve the prognosis of OHCAs with a work-colleague bystander.
Collapse
|
12
|
Large discrepancy in optimal atrioventricular delay between sensed and paced atrial events in a pacemaker patient. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2021; 45:435-438. [PMID: 34793604 DOI: 10.1111/pace.14412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Revised: 10/12/2021] [Accepted: 11/14/2021] [Indexed: 11/28/2022]
Abstract
A 74-year-old man experienced complete atrioventricular (AV) block 2 days after catheter ablation for right atrial (RA) macroreentrant tachycardia. We performed DDD pacemaker implantation with atrial septal pacing because other sites of pacing threshold were not acceptable. The maximum left ventricular outflow tract velocity time integral was 15.8 cm with sensed AV delay (40 ms) and 15.0 cm with paced AV delay (220 ms); however, this exceeded the pacemaker's maximum difference of 100 ms. We herein report the case of a large discrepancy in optimal AV delay intervals between sensed and paced atrial events, requiring consideration of proper pacemaker settings.
Collapse
|
13
|
Accessory pathway ablation during atrial fibrillation in Ebstein anomaly. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2021; 45:431-434. [PMID: 34752651 DOI: 10.1111/pace.14404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 09/27/2021] [Accepted: 11/05/2021] [Indexed: 12/01/2022]
Abstract
An 84-year-old woman with type B Wolff-Parkinson-White (WPW) with Ebstein anomaly was admitted with heart failure. She had rapid wide QRS tachycardia due to accessory pathway (AP) conduction associated with atrial fibrillation (AF). Since transesophageal echocardiography before catheter ablation showed a left atrial thrombus, ablation was performed using a 3D mapping system under AF. After marking the functional tricuspid anulus with intra-cardiac echocardiography, 3D intra-cardiac electrogram visualization (ripple map) during AF enabled clear identification of location of the AP. After ablation, there was no complication of cerebral infarction, and the heart failure improved.
Collapse
|
14
|
Adenosine revives catheter-induced mechanical blocks in radiofrequency ablation. J Cardiovasc Electrophysiol 2021; 32:3103-3106. [PMID: 34460986 DOI: 10.1111/jce.15235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 08/03/2021] [Accepted: 08/27/2021] [Indexed: 11/28/2022]
Abstract
Adenosine can hyperpolarize the atrial action potential, which helps rapidly re-establish the membrane potential in ablated sites and unmask "dormant conduction." It has been reported that pharmacological agents, including adenosine, were unable to revive traumatized tissues. We present the first case of the catheter-induced mechanical block ("bump" phenomenon) that was unmasked with adenosine administration in the working myocardium of the superior vena cava. This result may be because, unlike before, we could determine the force of contact between the tip of the ablation catheter and the myocardial tissue. This case suggests the clinical usefulness of adenosine for unmasking bumped sites.
Collapse
|
15
|
RR interval variability in the evaluation of ventricular tachycardia and effects of implantable cardioverter defibrillator therapy. J Arrhythm 2021; 37:1052-1060. [PMID: 34386132 PMCID: PMC8339111 DOI: 10.1002/joa3.12551] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 04/13/2021] [Accepted: 04/21/2021] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND An implantable cardioverter defibrillator (ICD) is the most reliable therapeutic device for preventing sudden cardiac death in patients with sustained ventricular tachycardia (VT). Regarding its effectiveness, targeted VT is defined based on the tachyarrhythmia cycle length. However, variations in RR interval variability of VTs may occur. Few studies have reported on VT characteristics and effects of ICD therapy according to the RR interval variability. We aimed to identify the clinical characteristics of VTs and ICD therapy effects according to the RR interval variability. METHODS We analyzed 821 VT episodes in 69 patients with ICDs or cardiac resynchronization therapy defibrillators. VTs were classified as irregular when the difference between two successive beats was >20 ms in at least one of 10 RR intervals; otherwise, they were classified as regular. We evaluated successful termination using anti-tachycardia pacing (ATP)/shock therapy, spontaneous termination, and acceleration between regular and irregular VTs. The RR interval variability reproducibility rates were evaluated. RESULTS Regular VT was significantly more successfully terminated than irregular VT by ATP. No significant difference was found in shock therapy or VT acceleration between the regular and irregular VTs. Spontaneous termination occurred significantly more often in irregular than in regular VT cases. The reproducibility rates of RR interval variability in each episode and in all episodes were 89% and 73%, respectively. CONCLUSIONS ATP therapy showed greater effectiveness for regular than for irregular VT. Spontaneous termination was more common in irregular than in regular VT. RR interval variability of VTs seems to be reproducible.
Collapse
|
16
|
Effects of bicarbonate/lactate-buffered neutral peritoneal dialysis fluids on angiogenesis-related proteins in patients undergoing peritoneal dialysis. RENAL REPLACEMENT THERAPY 2021. [DOI: 10.1186/s41100-021-00344-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
In order to facilitate the safe and long-term delivery of peritoneal dialysis (PD), it is necessary to improve the biocompatibility of peritoneal dialysis fluids (PDFs). The novel bicarbonate/lactate-buffered neutral PDFs (B/L-PDFs) are expected to be improved biocompatible. This study evaluated the biocompatibility of B/L-PDFs by analysis on the profile of angiogenesis-related proteins in drained dialysate of patients undergoing PD.
Methods
Concentrations of 20 angiogenesis-related proteins in the dialysate were semi-quantitatively determined using a RayBio® Human Angiogenesis Antibody Array and were compared between B/L-PDFs and conventional lactate-buffered neutral PDFs (L-PDFs).
Results
The expression of growth-related oncogene (GRO α/β/γ), which belongs to the CXC chemokine family, decreased significantly after use of the B/L-PDFs compared to the L-PDFs (P = 0.03). The number of the proteins with lower level in the B/L-PDFs compared with L-PDFs was significantly negatively correlated with the PD duration (Spearman ρ = − 0.81, P = 0.004).
Conclusion
This study suggested that B/L-PDFs are more biocompatible than conventional PDFs.
Collapse
|
17
|
The features and trends of out-of-hospital cardiac arrests in Japanese working generation: long-term aspects of a prospective, nationwide, population-based registry. Eur Heart J 2020. [DOI: 10.1093/ehjci/ehaa946.3513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Background
Despite sudden cardiac death (SCD) in working generation is a crucial issue in terms of public health, social and economic significance, the long-term SCD condition in working generation is unclear.
Purpose
This study aimed to clarify the features and long-term trends of SCD in working generation from 2005 through 2016 in Japan, using a prospective, nationwide, population based out-of-hospital cardiac arrest (OHCA) registry.
Methods
We performed data analysis of the nation-wide registry in Japan who experienced OHCA during the 12 years. Working generation was defined as 20 to 69 years and we analyzed only definitive cardiogenic OHCA as an approximation of SCD.
Results
The number of definitive cardiogenic OHCA of working generation during the period was 66,214 and 31% of the events in whole population was working generation. Definitive cardiogenic OHCA in working generation in terms of both number and percentage of the population had been decreased from 6522 (0.07‰) in 2005 to 4910 (0.06‰) in 2016, bystander cardiopulmonary resuscitation (CPR) and usage of automated external defibrillator (AED) ratio increased from 32.7% in 2005 to 49.6% in 2016, and 0.3% in 2005 to 14.7% in 2016 respectively, and the survival rate after one-month improved year by year, from 12.8% in 2005 to 34.0% in 2016 (picture below). Among non-medical bystanders, CPR was most often performed by colleagues in this generation, while AED use rate by colleague was smaller, and the time from witness to initial defibrillation was significantly longer than by passerby. Good prognosis was observed in terms of one-month survival ratio and neurological outcome for those undergoing CPR by colleague and passerby compared with other bystanders. For 12 years, although the degree varies, all non-medical bystander had same tendency; bystander CPR and usage of AED ratio increased, and the survival rate after one-month and neurological outcome improved year by year.
Conclusions
Not only the number but the incidence of cardiogenic OHCA in working generation has been decreased in Japan. The positive prognosis of this generation may be related to CPR by colleagues.
Figure 1. OHCA number & 1-month survival rate
Funding Acknowledgement
Type of funding source: None
Collapse
|
18
|
Oxytocin-monomeric red fluorescent protein 1 synthesis in the hypothalamus under osmotic challenge and acute hypovolemia in a transgenic rat line. Physiol Rep 2020; 8:e14558. [PMID: 32914562 PMCID: PMC7507703 DOI: 10.14814/phy2.14558] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 07/18/2020] [Accepted: 07/20/2020] [Indexed: 12/29/2022] Open
Abstract
We generated a transgenic rat line that expresses oxytocin (OXT)-monomeric red fluorescent protein 1 (mRFP1) fusion gene to visualize the dynamics of OXT. In this transgenic rat line, hypothalamic OXT can be assessed under diverse physiological and pathophysiological conditions by semiquantitative fluorometry of mRFP1 fluorescence intensity as a surrogate marker for endogenous OXT. Using this transgenic rat line, we identified the changes in hypothalamic OXT synthesis under various physiological conditions. However, few reports have directly examined hypothalamic OXT synthesis under hyperosmolality or hypovolemia. In this study, hypothalamic OXT synthesis was investigated using the transgenic rat line after acute osmotic challenge and acute hypovolemia induced by intraperitoneal (i.p.) administration of 3% hypertonic saline (HTN) and polyethylene glycol (PEG), respectively. The mRFP1 fluorescence intensity in the paraventricular (PVN) and supraoptic nuclei (SON) was significantly increased after i.p. administration of HTN and PEG, along with robust Fos-like immunoreactivity (co-expression). Fos expression showed neuronal activation in the brain regions that are associated with the hypothalamus and/or are involved in maintaining water and electrolyte homeostasis in HTN- and PEG-treated rats. OXT and mRFP1 gene expressions were dramatically increased after HTN and PEG administration. The plasma OXT level was extremely increased after HTN and PEG administration. Acute osmotic challenge and acute hypovolemia induced upregulation of hypothalamic OXT in the PVN and SON. These results suggest that not only endogenous arginine vasopressin (AVP) but also endogenous OXT has a key role in maintaining body fluid homeostasis to cope with hyperosmolality and hypovolemia.
Collapse
|
19
|
Rate-dependent pacing failure after pacemaker implantation: Novel insights into the mechanism of using adenosine. J Cardiovasc Electrophysiol 2020; 31:2765-2769. [PMID: 32757423 DOI: 10.1111/jce.14704] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Revised: 07/21/2020] [Accepted: 07/26/2020] [Indexed: 11/27/2022]
Abstract
An 82-year-old woman received pacemaker implantation for sick sinus syndrome. Two days after the implantation, electrocardiography showed 2:1 atrial pacing failure, followed by a bradycardia-dependent increase in the atrial pacing threshold during a pacemaker examination. However, transient 1:1 atrial pacing capture recovered by adenosine triphosphate (ATP) administration, which was performed to evaluate the bradycardia-dependent pacing failure mechanism. We considered this phenomenon to be caused by Phase 4 depolarization and avoided replacing this atrial lead. Three weeks later, the atrial pacing threshold had improved. We report the potential role of Phase 4 depolarization in a bradycardia-dependent increase in pacing threshold by using ATP.
Collapse
|
20
|
A case of balloon angioplasty guided by integrated backscatter intravascular ultrasound for the treatment of pulmonary vein stenosis caused by radiofrequency atrial fibrillation. HeartRhythm Case Rep 2020; 5:465-467. [PMID: 31934542 PMCID: PMC6951306 DOI: 10.1016/j.hrcr.2019.06.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
|
21
|
Prevention of serious air embolism during cryoballoon ablation; risk assessment of air intrusion into the sheath by catheter selection and change in intrathoracic pressure: An ex vivo study. J Cardiovasc Electrophysiol 2019; 30:2944-2949. [PMID: 31588621 DOI: 10.1111/jce.14208] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 09/06/2019] [Accepted: 09/23/2019] [Indexed: 11/27/2022]
Abstract
INTRODUCTION One cause of cerebral infarction during cryoballoon ablation is the entry of air into a sheath due to the use of inappropriate catheters. It is known that the left atrial pressure of patients with obstructive sleep apnea syndrome can be negative. However, the effects of catheter selection and negative pressure changes in the sheath on air intrusion are not yet well understood. The aim of this study was to evaluate how catheter selection and negative pressure changes affect air intrusion and to perform countermeasures for air intrusion. METHODS AND RESULTS This experiment used siphon principle to create negative pressure in the sheath. Noncryoablation catheters (not designed exclusively for cryoballoon ablation) and cryoballoon catheters were investigated. Catheters were inserted into the sheath and then removed. Thereafter, the amount of air in the sheath was measured. For catheters producing significantly larger amounts of air intrusion, the catheters were inserted via a long sheath in the sheath (sheath-in-sheath technique) and the same procedures were repeated. We found that the amount of air intrusion through most of the noncryoablation catheters was significantly larger than that through cryoablation catheters. An increase in the magnitude of negative pressure in the sheath resulted in a proportional increase in air intrusion, but the sheath-in-sheath technique significantly reduced air intrusion. CONCLUSION The amount of air intrusion increased when using catheters with complicated tip shapes and thin outer diameters and when the magnitude of negative pressure in the sheath increased. The sheath-in-sheath technique may be an effective countermeasure.
Collapse
|
22
|
Bleeding and ischemic events during dual antiplatelet therapy after second-generation drug-eluting stent implantation in hemodialysis patients. J Cardiol 2019; 73:470-478. [DOI: 10.1016/j.jjcc.2018.12.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2018] [Revised: 10/23/2018] [Accepted: 10/29/2018] [Indexed: 10/27/2022]
|
23
|
Impact of High-Sensitivity Cardiac Troponin Elevation in Relation to Diagnostic Invasive Intravascular Imaging for the Assessment of Coronary Artery Disease. Int Heart J 2019; 60:601-607. [PMID: 31105151 DOI: 10.1536/ihj.18-448] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Recent studies reported that cardiac troponin elevation after percutaneous coronary intervention is related to adverse cardiac events. Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) are often used to assess lesion characteristics in the coronary arteries. However, little is known about the trend of cardiac troponin elevation after diagnostic invasive intracoronary examination and the prognostic influence. We assessed the relationship between myocardial injury manifested by the high-sensitivity cardiac troponin T (hs-cTnT) level after invasive intracoronary examination and future adverse cardiac outcomes. We evaluated 115 patients with stable coronary artery disease who underwent IVUS or OCT for detailed coronary assessment during coronary angiography (CAG). Baseline and post-procedural (within 24 hours after examination) hs-cTnT were measured. In consequence, post-procedural hs-cTnT level and percentage increase were higher in patients with IVUS or OCT during CAG than in those without. Periprocedural myocardial injury (PMI, defined as post-procedural hs-cTnT with upper reference limit greater than five-fold) occurred in 10 (8.6%) patients. There were no significant differences in baseline characteristics between patients with and without PMI, except for left-ventricular diastolic dimension. Only two major adverse cardiac events (MACE, defined as cardiovascular death, nonfatal myocardial infarction, and target lesion revascularization) occurred in non-PMI during a mean observation period of 32 ± 18 months. On Kaplan-Meier analysis, MACE-free survival rate was similar between PMI and non-PMI. In conclusion, a few imperceptible PMI derived by hs-cTnT assay occurred after diagnostic invasive intracoronary examination. However, it was not associated with subsequent poor cardiac outcome.
Collapse
|
24
|
Prognostic impact of lead tip position confirmed via computed tomography in patients with right ventricular septal pacing. Heart Rhythm 2019; 16:921-927. [PMID: 30633981 DOI: 10.1016/j.hrthm.2019.01.008] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2018] [Indexed: 10/27/2022]
Abstract
BACKGROUND Although fluoroscopy-guided right ventricular (RV) lead placement in the ventricular septum is a widely performed procedure, variation in true RV lead tip position confirmed via computed tomography (CT) and its prognostic implications in patients with atrioventricular block (AVB) are not well understood. OBJECTIVE The purpose of this study was to evaluate the prognostic impact of CT-confirmed RV lead tip position. METHODS We retrospectively enrolled 228 consecutive patients (age 77 ± 10 years; 125 men) with AVB who underwent fluoroscopy-guided RV septal lead implantation and thoracic CT after pacemaker implantation. Patients were classified into septal and free-wall groups according to RV lead tip position. The primary endpoint was the composite outcome of cardiac death and heart failure hospitalization. RESULTS The RV lead tip was located at the free wall in 18 patients (8%). The primary endpoint occurred in 37 patients (16%) over median follow-up of 41 months. Electrocardiographic analysis found that R amplitude >0.53 mV in lead I was significantly predictive of free-wall pacing, with sensitivity of 70% and specificity of 77%. Multivariate Cox regression analysis demonstrated that the lead tip in the free wall (hazard ratio 2.93; 95% confidence interval 1.21-7.11; P = .018) was an independent predictor of the primary endpoint. CONCLUSION Fluoroscopy-guided RV lead placement carries potential risk of unexpected RV free-wall pacing and may increase the risk of cardiac death and heart failure-related hospitalization in patients undergoing RV septal pacing due to AVB and receiving thoracic CT for medical reasons.
Collapse
|
25
|
Clinical Manifestations and Long-Term Mortality in Lamin A/C Mutation Carriers From a Japanese Multicenter Registry. Circ J 2018; 82:2707-2714. [PMID: 30078822 DOI: 10.1253/circj.cj-18-0339] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Mutation in the lamin A/C gene (LMNA) is associated with several cardiac phenotypes, such as cardiac conduction disorders (CCD), atrial arrhythmia (AA), malignant ventricular arrhythmia (MVA) and left ventricular dysfunction (LVD), leading to sudden cardiac death (SCD) and/or end-stage heart failure. We investigated how these phenotypes are associated with each other and which of them are most important for total mortality. Methods and Results: A multicenter registry included 110 LMNA mutation carriers (age, 43±15 years, male: 62%) from 60 families. After genetic diagnosis of LMNA mutation (missense: 27%, non-missense: 73%), patients or subjects were followed to evaluate the manifestations of their phenotypes and the risk of total mortality; 90 patients could be followed (median: 5 [0-35] years). Prevalence of the 4 clinical phenotypes was significantly increased during follow-up. Among these phenotypes, AA was significantly associated with MVA. CCD was significantly associated with LVD. LVD, meanwhile, was significantly associated with CCD and MVA. Male sex was significantly associated with MVA. Furthermore, during follow-up, 17 patients died: 12 end-stage heart failure, 4 SCD and 1 stroke. LVD was the only independent predictor for all-cause death (OR: 41.7, 95% CI: 4.1-422.3; P=0.0016). CONCLUSIONS Several cardiac phenotypes were age-dependently increased in LMNA mutation carriers, suggesting that ICD or CRT-D could suppress SCD after middle age; however, LVD leading to end-stage heart failure was the only independent predictor for total mortality.
Collapse
|
26
|
Contribution of Poststent Irregular Protrusion to Subsequent In-Stent Neoatherosclerosis after the Second-Generation Drug-Eluting Stent Implantation. Int Heart J 2018; 59:307-314. [DOI: 10.1536/ihj.17-463] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
27
|
Gene-Based Risk Stratification for Cardiac Disorders in
LMNA
Mutation Carriers. ACTA ACUST UNITED AC 2017; 10:CIRCGENETICS.116.001603. [DOI: 10.1161/circgenetics.116.001603] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2016] [Accepted: 09/25/2017] [Indexed: 01/01/2023]
Abstract
Background—
Mutations in
LMNA
(
lamin A/C
), which encodes lamin A and C, typically cause age-dependent cardiac phenotypes, including dilated cardiomyopathy, cardiac conduction disturbance, atrial fibrillation, and malignant ventricular arrhythmias. Although the type of
LMNA
mutations have been reported to be associated with susceptibility to malignant ventricular arrhythmias, the gene-based risk stratification for cardiac complications remains unexplored.
Methods and Results—
The multicenter cohort included 77
LMNA
mutation carriers from 45 families; cardiac disorders were retrospectively analyzed. The mean age of patients when they underwent genetic testing was 45±17, and they were followed for a median 49 months. Of the 77 carriers, 71 (92%) were phenotypically affected and showed cardiac conduction disturbance (81%), low left ventricular ejection fraction (<50%; 45%), atrial arrhythmias (58%), and malignant ventricular arrhythmias (26%). During the follow-up period, 9 (12%) died, either from end-stage heart failure (n=7) or suddenly (n=2). Genetic analysis showed truncation mutations in 58 patients from 31 families and missense mutations in 19 patients from 14 families. The onset of cardiac disorders indicated that subjects with truncation mutations had an earlier occurrence of cardiac conduction disturbance and low left ventricular ejection fraction, than those with missense mutations. In addition, the truncation mutation was found to be a risk factor for the early onset of cardiac conduction disturbance and the occurrence of atrial arrhythmias and low left ventricular ejection fraction, as estimated using multivariable analyses.
Conclusions—
The truncation mutations were associated with manifestation of cardiac phenotypes in
LMNA
-related cardiomyopathy, suggesting that genetic analysis might be useful for diagnosis and risk stratification.
Collapse
|
28
|
Miniaturized Leadless Cardiac Pacemakers - Can They Overcome the Problems With Transvenous Pacing Systems? Circ J 2017; 81:1576-1577. [PMID: 29021417 DOI: 10.1253/circj.cj-17-0933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
29
|
1678Is pacemaker therapy essential in all patients with ictal asystole? Europace 2017. [DOI: 10.1093/ehjci/eux160.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
30
|
Superior Rhythm Discrimination With the SmartShock Technology Algorithm - Results of the Implantable Defibrillator With Enhanced Features and Settings for Reduction of Inaccurate Detection (DEFENSE) Trial. Circ J 2017; 81:1272-1277. [PMID: 28428489 DOI: 10.1253/circj.cj-16-1330] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Shocks delivered by implanted anti-tachyarrhythmia devices, even when appropriate, lower the quality of life and survival. The new SmartShock Technology®(SST) discrimination algorithm was developed to prevent the delivery of inappropriate shock. This prospective, multicenter, observational study compared the rate of inaccurate detection of ventricular tachyarrhythmia using the SST vs. a conventional discrimination algorithm.Methods and Results:Recipients of implantable cardioverter defibrillators (ICD) or cardiac resynchronization therapy defibrillators (CRT-D) equipped with the SST algorithm were enrolled and followed up every 6 months. The tachycardia detection rate was set at ≥150 beats/min with the SST algorithm. The primary endpoint was the time to first inaccurate detection of ventricular tachycardia (VT) with conventional vs. the SST discrimination algorithm, up to 2 years of follow-up. Between March 2012 and September 2013, 185 patients (mean age, 64.0±14.9 years; men, 74%; secondary prevention indication, 49.5%) were enrolled at 14 Japanese medical centers. Inaccurate detection was observed in 32 patients (17.6%) with the conventional, vs. in 19 patients (10.4%) with the SST algorithm. SST significantly lowered the rate of inaccurate detection by dual chamber devices (HR, 0.50; 95% CI: 0.263-0.950; P=0.034). CONCLUSIONS Compared with previous algorithms, the SST discrimination algorithm significantly lowered the rate of inaccurate detection of VT in recipients of dual-chamber ICD or CRT-D.
Collapse
|
31
|
Left Atrial Remodeling in Segmental vs. Global Mitral Valve Prolapse - Three-Dimensional Echocardiography. Circ J 2016; 80:2533-2540. [PMID: 27829586 DOI: 10.1253/circj.cj-16-0694] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Segmental and global mitral valve prolapse (MVP) comprise 2 representative phenotypes in this syndrome. While mitral regurgitation (MR) severity is a major factor causing left atrial (LA) remodeling in MVP, prominent mitral valve (MV) annulus dilatation in global MVP may specifically cause inferiorly predominant LA remodeling. We compared MV annulus and LA geometry in patients with segmental and global MVP.Methods and Results:LA volume as well as inferior, middle, and superior LA cross-sectional areas (CSA) were measured on 3-D echocardiography in 20 controls, in 40 patients with segmental MVP, and in 18 with global MVP. On multivariate analysis, MR severity was primarily associated with LA dilatation in segmental MVP (P<0.001), while MV annular dilatation was primarily associated with LA dilatation in global MVP (P<0.001). Although there was no regional predominance in LA dilatation in segmental MVP, inferior predominance of LA dilatation was significant in global MVP (increase in inferior, middle, and superior LA-CSA relative to mean of the controls: +220±70% vs. +171±55% vs. +137±37%, P<0.001). CONCLUSIONS LA remodeling in segmental and global MVP is considerably different regarding its association with MR volume or MV annular dilatation and its regional predominance. While MR volume may mainly contribute to LA remodeling in segmental MVP, MV annular dilatation seems to have an important role in LA remodeling in global MVP. (Circ J 2016; 80: 2533-2540).
Collapse
|
32
|
Basal Left Ventricular Dilatation and Reduced Contraction in Patients With Mitral Valve Prolapse Can Be Secondary to Annular Dilatation. Circ Cardiovasc Imaging 2016; 9:CIRCIMAGING.115.005113. [DOI: 10.1161/circimaging.115.005113] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Accepted: 09/12/2016] [Indexed: 11/16/2022]
Abstract
Background—
Prominent mitral valve (MV) annular dilatation with only modest left ventricular (LV) dilatation in patients with MV prolapse (MVP) suggests predominant dilatation in adjacent basal LV, which may augment regional wall tension and attenuate contraction by Laplace’s law. We hypothesized that MV annular dilatation in patients with MVP is associated with the basal predominance of LV dilatation and attenuated contraction, which can be altered by surgical MV plasty with annulus reduction.
Methods and Results—
Echocardiography with speckle-tracking analysis to assess regional cross-sectional short-axis area and longitudinal contraction (strain) of basal, middle, and apical LV was performed in 30 controls and 130 patients with MVP. The basal value/averaged middle and apical values (B/M·A ratio) of LV cross-sectional area and strain were obtained. Patients with MVP showed significantly greater MV annular area (6.4±1.6 versus 3.7±0.6 cm
2
/m
2
), increased B/M·A LV area ratio (2.4±0.5 versus 1.8±0.2), and reduced B/M·A LV strain ratio (0.83±0.14 versus 0.96±0.09) than controls (
P
<0.001). Multivariable analyses identified that MV annular dilatation was independently associated with increased B/M·A LV area ratio (β=0.60,
P
<0.001), which was associated with reduced B/M·A LV strain ratio (β=−0.32,
P
<0.001). In 35 patients with MVP, B/M·A LV area and strain ratio significantly altered after surgical MV plasty with annulus reduction (2.5±0.5–1.8±0.3 and 0.73±0.10–0.89±0.17,
P
<0.001, respectively).
Conclusions—
In patients with MVP, MV annular dilatation was associated with the basal predominance of LV dilatation and reduced contraction, which can be altered by surgical MV plasty with annulus reduction, suggesting unfavorable influence from MV annular dilatation on basal LV.
Collapse
|
33
|
Non-Reentrant Fascicular Tachycardia. Circ Arrhythm Electrophysiol 2016; 9:CIRCEP.116.004177. [DOI: 10.1161/circep.116.004177] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2016] [Accepted: 08/23/2016] [Indexed: 11/16/2022]
Abstract
Background—
The most common form of idiopathic Purkinje-related ventricular tachycardia (VT) is the reentrant type. We describe the clinical and electrophysiological characteristics of focal non-reentrant fascicular tachycardia.
Methods and Results—
Among 530 idiopathic VT patients who were referred for ablation, we identified 15 (2.8%) with non-reentrant fascicular tachycardia (11 men, 45±21 years). Sinus rhythm ECG showed normal conduction intervals with a His–ventricular interval of 41±4 ms. All patients had monomorphic VT (cycle length: 337±88 ms) with a relatively narrow QRS (123±12 ms), and they did not respond to verapamil during the initial presentation. VT exhibited right bundle-branch block/superior axis configuration in 11 patients (73%) and inferior axis in 3 (20%). In 1 patient (7%), VT exhibited left bundle-branch block/superior axis configuration. During ablation, spontaneous VT occurred in 3 patients (20%) and nonentraintable VT or identical premature ventricular complex was induced in 9 (60%). A high-frequency presystolic Purkinje potential was recorded during VT/premature ventricular complex, preceding the QRS by 25±16 ms. VT recurrence was observed in 4 patients (27%), and among them, 3 underwent pacemap-guided ablation during the first session. A second ablation with activation mapping guidance eliminated the VT during the 88±8-month follow-up.
Conclusions—
Among idiopathic VT cases referred for ablation, 2.8% were focal non-reentrant fascicular tachycardia, which had distinct clinical characteristics and usually originated from the left posterior fascicle, and less commonly from the left anterior fascicle and right ventricular Purkinje network. Catheter ablation is effective, whereas pacemap-guided approach is less efficacious.
Collapse
|
34
|
Outcomes of single- or dual-chamber implantable cardioverter defibrillator systems in Japanese patients. J Arrhythm 2016; 32:89-94. [PMID: 27092188 PMCID: PMC4823579 DOI: 10.1016/j.joa.2015.09.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2015] [Revised: 09/06/2015] [Accepted: 09/14/2015] [Indexed: 12/05/2022] Open
Abstract
Background There are no criteria for selecting single- or dual-chamber implantable cardioverter defibrillators (ICDs) in patients without a pacing indication. Recent reports showed no benefit of the dual-chamber system despite its preference in the United States. As data on ICD selection and respective outcomes in Japanese patients are scarce, we investigated trends regarding single- and dual-chamber ICD usage in Japan. Methods Data from a total of 205 ICD recipients with structural heart disease (median age, 63 years) in two Japanese university hospitals were reviewed. Patients with bradycardia with a pacing indication and permanent atrial fibrillation at implantation were excluded. Results Single- and dual-chamber ICDs were implanted in 36 (18%) and 169 (82%) patients, respectively. Non-ischemic cardiomyopathy dominated both groups. Seventeen dual-chamber patients developed atrial pacing-dependency over 4.5 years, and it developed immediately after implantation in 14. Although preoperative testing showed no sign of bradycardia in these patients, their pacing rate was set higher than it was in patients who were pacing-independent (61 vs. 46 paces per min, p<0.01). Two single-chamber patients (5%) underwent atrial lead insertion. While inappropriate shock equally occurred in both groups (7 vs. 21 patients, single- vs. dual-chamber, P=0.285), device-related infection occurred only in dual-chamber patients (0 vs. 9 patients, P=0.155). No differences in death or heart failure hospitalization were observed between groups. Conclusions Dual-chamber ICDs were four-fold more common in Japanese patients without a pacing indication. No benefit over single-chamber ICD was observed. Newly developed atrial pacing-dependency seemed to be limited and could have been overestimated due to higher pacing rate settings in dual-chamber patients.
Collapse
|
35
|
Impact of additional intracoronary nicorandil administration during fractional flow reserve measurement with intravenous adenosine 5'-triphosphate infusion. J Cardiol 2016; 69:119-124. [PMID: 26947100 DOI: 10.1016/j.jjcc.2016.01.018] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2015] [Revised: 01/22/2016] [Accepted: 01/28/2016] [Indexed: 10/22/2022]
Abstract
BACKGROUND Fractional flow reserve (FFR) is a useful index for determining the functional severity of epicardial coronary artery stenosis as an invasive physiological method. Although intravenous adenosine 5'-triphosphate (ATP) is generally used as a hyperemic agent for FFR measurement in Japan, there are some concerns about the variability of FFR measurement (short half-life, effect of caffeine, cyclic change). It is difficult to confirm sufficient maximum hyperemia after ATP infusion. Recent studies reported that nicorandil (NIC) could be an alternative to ATP as a hyperemic agent. METHODS Patients who underwent FFR assessments of angiographically intermediate lesions were included. All patients were asked to refrain from caffeine-containing products more than 12hours before FFR measurements. All patients first received intravenous (IV) ATP infusion (180μg/kg/min) for 3min to measure FFR (ATP-FFR). After additional intracoronary (IC) NIC administration (2mg/30s) during ATP infusion, FFR was measured again (NIC-FFR). To check cyclic change in FFR, we measured minimum and maximum FFR values during both ATP and NIC hyperemic phase. RESULTS In this study, 94 patients with 94 lesions were enrolled. Mean FFR value was 0.81±0.10 in ATP-FFR infusion and 0.80±0.09 in NIC-FFR, respectively. ATP-FFR and NIC-FFR had a strong correlation on the whole (r=0.92, p<0.001). In 18 patients (19%), FFR values were significantly lower in NIC-FFR than in ATP-FFR. In one-third of those patients (6%), it was possible to change therapeutic strategy from deferral range (>0.80) to interventional range (≦0.80) after NIC-FFR measurements. Cyclic change in FFR was smaller in NIC-FFR than in ATP-FFR (0.03±0.02 vs. 0.06±0.05, p<0.0001). CONCLUSION Additional IC NIC might be useful to confirm sufficient maximum hyperemia after IV ATP infusion in daily clinical practice. Furthermore, IC NIC could reduce cyclic change in FFR; thus, physicians might find it easier to determine FFR value during the procedure.
Collapse
|
36
|
Effects of right ventricular pacing sites on blood pressure variation in upright posture: a comparison of septal vs. apical pacing sites. Europace 2016; 18:1023-9. [PMID: 26851814 DOI: 10.1093/europace/euv298] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2015] [Accepted: 08/05/2015] [Indexed: 11/15/2022] Open
Abstract
AIMS Large variations in blood pressure (BP) in the upright position are a major cause of pacemaker syndrome, observed in up to 80% of patients paced non-physiologically at the right ventricular (RV) apex. We hypothesized that the magnitude of BP variations might be influenced by the RV pacing site. To assess this, we compared haemodynamic findings during supine and upright posture with RV apical vs. septal pacing. METHODS AND RESULTS The study population comprised a retrospective cohort of 24 dual-chamber pacemaker patients with advanced or complete atrioventricular block, in which 11 were randomly chosen from those with RV apical pacing, and 13 randomly chosen from those with septal pacing. Studies were performed during fixed rate VVI and DDD pacing modes with patients in both supine and passive head-up tilt positions. Continuous BP, stroke volume, cardiac index, and total peripheral resistance index were measured non-invasively. During RV apical pacing, there were significant differences of beat-to-beat BP variation after movement from supine to upright posture for both VVI and DDD pacing modes (P < 0.05); however, this was not the case for either mode during RV septal pacing. Further, comparing RV apical to RV septal pacing in the supine position, there were no BP variation differences for either DDD or VVI modes. Conversely, in the upright position BP variation was significantly greater during RV apical vs. RV septal VVI pacing (P = 0.017) but not during DDD pacing. CONCLUSION During VVI pacing, RV septal pacing exhibited lesser BP variation during upright posture compared with RV apical pacing.
Collapse
|
37
|
Pacing From the Right Ventricular Septum and Development of New Atrial Fibrillation in Paced Patients With Atrioventricular Block and Preserved Left Ventricular Function. Circ J 2016; 80:2302-2309. [DOI: 10.1253/circj.cj-16-0640] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
38
|
Left atrial appendage thrombus in a patient with sinus rhythm and left atrial appendage dysfunction. J Echocardiogr 2015; 13:157-8. [PMID: 26403481 DOI: 10.1007/s12574-015-0262-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2015] [Revised: 08/29/2015] [Accepted: 08/31/2015] [Indexed: 10/23/2022]
|
39
|
Genotype-dependent differences in age of manifestation and arrhythmia complications in short QT syndrome. Int J Cardiol 2015; 190:393-402. [DOI: 10.1016/j.ijcard.2015.04.090] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2015] [Revised: 04/03/2015] [Accepted: 04/14/2015] [Indexed: 11/16/2022]
|
40
|
Different characteristics of heart failure due to pump failure and bradyarrhythmia. J Echocardiogr 2014; 13:27-34. [PMID: 25750577 PMCID: PMC4346665 DOI: 10.1007/s12574-014-0235-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2014] [Revised: 11/20/2014] [Accepted: 11/25/2014] [Indexed: 11/29/2022]
Abstract
Background Heart failure (HF) can be caused by left ventricular (LV) pump failure as well as by bradyarrhythmias. Hemodynamic differences between HF by LV pump failure and that by bradyarrhythmia have not been fully investigated. We hypothesized that HF by LV pump failure could be associated with both reduced cardiac output (CO) and increased LV filling pressure due to associated LV diastolic dysfunction, whereas HF by bradyarrhythmia could be associated with reduced CO but only modestly increased LV filling pressure due to the absence of LV diastolic dysfunction. Methods In 39 patients with HF by LV pump failure (LV ejection fraction <35 %), 24 with HF by bradyarrhythmia, and 22 normal controls, LV volume, ejection fraction, stroke volume, left atrial volume, and early diastolic mitral valve flow to tissue annular velocity ratio (E/E′) were measured by echocardiography. Results Compared to patients with HF by LV pump failure, those with HF by bradyarrhythmia had significantly lower heart rates, less LV dilatation, preserved LV ejection fraction, preserved stroke volume, similarly reduced cardiac index (1.8 ± 0.4 vs. 1.6 ± 0.4 L/min/m2, n.s.), preserved LV diastolic function (E′) (4.4 ± 2.1 vs. 7.1 ± 2.9 cm/s, p < 0.001), less dilated end-systolic LA volume, and preserved E/E′ (24 ± 10 vs. 13 ± 7, p < 0.001). Conclusions HF by LV pump failure is characterized by both significantly reduced CO and increased LV filling pressure, whereas HF by bradyarrhythmia is characterized by a similar reduction in CO but only modestly increased LV filling pressure.
Collapse
|
41
|
Pacing and sensing interference by air bubble surrounding the non-extended helix of intact active fixation lead. Circ J 2014; 78:2862-6. [PMID: 25283686 DOI: 10.1253/circj.cj-14-0736] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Active fixation pacing leads with silicon cylinder tips have been used for their safety and flexibility. Measurement of baseline sensing/pacing characteristics before fixation of helix helps to identify the optimal pacing site, but we encountered difficulties in making these measurements despite multiple attempts with the model LPA 1200M lead. To identify the cause and overcome this complication, we compared 4 different retractable active fixation lead models, which enabled baseline sensing/pacing measurements before extension of helix. METHODS AND RESULTS: We immersed 4 different lead tips and rings in a 0.18% saline solution, and measured the lead impedance before and after flushing of air bubble visible inside the lead tip. Before evacuation of the air bubble, the impedance of the model LPA 1200M lead was >4,000 Ω in 8 out of 10 measurements, although that of the other leads was within the measurable range. After evacuation of the air bubble, the lead impedance returned to within the measurable range. There was no prominent change in the impedance of the metal cylinder tip lead. CONCLUSIONS Air bubbles may interfere with the measurement of baseline sensing/pacing characteristics before active fixation of pacing leads with cylindrical silicon tips. In the case of high impedance beyond the measurable range before extension of helix, the measurement should be repeated after fixation into the myocardium before suspecting lead dysfunction.
Collapse
|
42
|
Atrial pacing site and atrioventricular conduction in patients paced for sinus node disease. J Cardiovasc Electrophysiol 2014; 25:1224-31. [PMID: 24946835 DOI: 10.1111/jce.12476] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2014] [Revised: 06/10/2014] [Accepted: 06/15/2014] [Indexed: 11/28/2022]
Abstract
BACKGROUND Unnecessary ventricular pacing in sinus node disease (SND) must be avoided. To test the hypothesis that in SND, with or without 1st degree atrioventricular (AV) block, cumulative percent ventricular pacing (cum%VP) can be limited by low right atrial septal (LRAS) instead of right atrial appendage (RAA) pacing. METHODS We studied 102 dual-chamber pacemaker recipients with SND. The PQ interval on 12-lead electrocardiogram and the atrial paced to ventricular sensed interval (Ap-Vs) during LRAS and RAA pacing were measured and compared at implantation, 3 months and 1 year of follow-up. Group 1 included 62 patients with baseline PQ interval <200 milliseconds during LRAS (n = 28) versus RAA (n = 34) pacing. Group 2 included 40 patients with baseline PQ ≥200 milliseconds during LRAS (n = 20) versus RAA (n = 20) pacing. cum%VP were measured at 3 months and 1 year. RESULTS The characteristics and AV conduction properties were similar and the Ap-Vs interval was significantly shorter in the LRAS than in the RAA pacing group up to 1 year (193 ± 32 milliseconds vs. 220 ± 27 milliseconds in Group 1; P = 0.003, 222 ± 41 milliseconds vs. 281 ± 30 milliseconds in Group 2; P < 0.001). While cumulative percent atrial pacing was consistently similar, cum%VP was significantly smaller during LRAS than RAA pacing (1 ± 1% vs. 8 ± 18% in Group 1; P = 0.03, 7 ± 10% vs. 48 ± 38% in Group 2; P < 0.001). Similar observations were made with or without left atrial (LA) enlargement. CONCLUSION Compared with RAA, LRAS pacing showed shorter AV interval in SND patients with or without 1st degree AV block and LA enlargement. This beneficial effect persisted through 1-year follow-up, and decreased cum%VP significantly.
Collapse
|
43
|
Sodium channelopathy underlying familial sick sinus syndrome with early onset and predominantly male characteristics. Circ Arrhythm Electrophysiol 2014; 7:511-7. [PMID: 24762805 DOI: 10.1161/circep.113.001340] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
BACKGROUND Sick sinus syndrome (SSS) is a common arrhythmia often associated with aging or organic heart diseases but may also occur in a familial form with a variable mode of inheritance. Despite the identification of causative genes, including cardiac Na channel (SCN5A), the pathogenesis and molecular epidemiology of familial SSS remain undetermined primarily because of its rarity. METHODS AND RESULTS We genetically screened 48 members of 15 SSS families for mutations in several candidate genes and determined the functional properties of mutant Na channels using whole-cell patch clamping. We identified 6 SCN5A mutations including a compound heterozygous mutation. Heterologously expressed mutant Na channels showed loss-of-function properties of reduced or no Na current density in conjunction with gating modulations. Among 19 family members with SCN5A mutations, QT prolongation and Brugada syndrome were associated in 4 and 2 individuals, respectively. Age of onset in probands carrying SCN5A mutations was significantly less (mean±SE, 12.4±4.6 years; n=5) than in SCN5A-negative probands (47.0±4.6 years; n=10; P<0.001) or nonfamilial SSS (74.3±0.4 years; n=538; P<0.001). Meta-analysis of SSS probands carrying SCN5A mutations (n=29) indicated profound male predominance (79.3%) resembling Brugada syndrome but with a considerably earlier age of onset (20.9±3.4 years). CONCLUSIONS The notable pathophysiological overlap between familial SSS and Na channelopathy indicates that familial SSS with SCN5A mutations may represent a subset of cardiac Na channelopathy with strong male predominance and early clinical manifestations.
Collapse
|
44
|
Identifying atrial arrhythmias versus pacing-induced rhythm disorders with state-of-the-art cardiac implanted devices. J Arrhythm 2014. [DOI: 10.1016/j.joa.2014.03.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
|
45
|
|
46
|
|
47
|
A 2:1 AV rhythm: an adverse effect of a long AV delay during DDI pacing and its prevention by the ventricular intrinsic preference algorithm in DDD mode. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2011; 35:e189-92. [PMID: 21671954 DOI: 10.1111/j.1540-8159.2011.03152.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A 91-year-old woman received a dual-chamber pacemaker for sick sinus syndrome and intermittently abnormal atrioventricular (AV) conduction. The pacemaker was set in DDI mode with a 350-ms AV delay to preserve intrinsic ventricular activity. She complained of palpitation during AV sequential pacing. The electrocardiogram showed a 2:1 AV rhythm from 1:1 ventriculoatrial (VA) conduction during ventricular pacing in DDI mode with a long AV interval. After reprogramming of the pacemaker in DDD mode with a 250-ms AV interval and additional 100-ms prolongation of the AV interval by the ventricular intrinsic preference function, VA conduction disappeared and the patient's symptom were alleviated without increasing unnecessary right ventricular pacing.
Collapse
|
48
|
Failure of atrial capture during DDIR pacing in a patient with sinus node disease and preserved atrioventricular conduction: what is the mechanism? PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2011; 34:1301. [PMID: 21438893 DOI: 10.1111/j.1540-8159.2011.03077.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
49
|
Poster presentation. Europace 2011. [DOI: 10.1093/europace/euq492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|