1
|
She YM, Ge N. Diagnostic value of endoscopic ultrasound in groove pancreatitis. Ann Med 2023; 55:2295991. [PMID: 38134890 PMCID: PMC10763902 DOI: 10.1080/07853890.2023.2295991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Accepted: 12/12/2023] [Indexed: 12/24/2023] Open
Abstract
Aim: Groove pancreatitis (GP) is a rare type of chronic pancreatitis characterized by varying degrees of thickening and scarring of the duodenal wall, duodenal lumen stenosis, mucosal hypertrophy with plicae and cyst formation. GP is primarily observed in middle-aged male patients with a history of alcohol consumption. Clinical symptoms are usually non-specific, and there is currently no unified diagnostic standard. However, imaging methods, particularly endoscopic ultrasound (EUS), are useful for diagnosis. EUS-guided biopsy can provide a strong basis for the final diagnosis. This review summarizes the value of EUS and its derivative technologies in the diagnosis, differential diagnosis and treatment of GP.Methods: After searching in PubMed and Web of Science databases using 'groove pancreatitis (GP)' and 'endoscopic ultrasonography (EUS)' as keywords, studies related were compiled and examined.Results: EUS and its derivative technologies are of great significance in the diagnosis, differential diagnosis, and treatment of GP, but there are still limitations that need to be comprehensively applied with other diagnostic methods to obtain the most accurate results.Conclusion: EUS has unique value in both the diagnosis and treatment of GP. Clinicians need to be well-versed in the advantages and limitations of EUS for GP diagnosis to select the most suitable imaging diagnostic method for different cases and to reduce the unnecessary waste of medical resources.
Collapse
Affiliation(s)
- Yu Mo She
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Nan Ge
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang, China
| |
Collapse
|
2
|
She YM, Ge N. Clinical application and follow-up of electrocautery-enhanced lumen-apposing metal stents for endoscopic ultrasonography-guided interventions. Ann Med 2023; 55:2282748. [PMID: 37967551 PMCID: PMC10653748 DOI: 10.1080/07853890.2023.2282748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 11/06/2023] [Indexed: 11/17/2023] Open
Abstract
Aim: The lumen-apposing metal stent (LAMS) is a new device that expands the scope of gastrointestinal intervention under endoscopy. LAMS was initially used for the treatment of pancreatic fluid collections (PFCs), but is increasingly being used off-label. The electrocautery system simplifies the deployment of LAMS, making it more suitable for off-label situations. The short-term results of electrocautery-enhanced lumen-apposing metal stents (ECE-LAMS) are satisfactory; however, the long-term follow-up results must be evaluated. The aim of this article is to review the expanded clinical application of ECE-LAMS, the clinical value of on-label and off-label use, and follow-up results.Methods: After searching in PubMed and Web of Science databases using 'electrocautery-enhanced lumen-apposing metal stents' and 'endoscopic ultrasonography (EUS) -guided interventions' as keywords, studies related were compiled and examined.Results: ECE-LAMS are widely used for on-label and off-label situations. The short-term and long-term results of ECE-LAMS are satisfactory, but there are still some studies that do not agree with this viewpoint.Conclusion: The clinical application of ECE-LAMS is relatively safe and reliable but more well-designed randomized trials and prospective studies are needed to evaluate the impact of this technology on therapeutic EUS, to improve the safety and success rate of EUS-guided LAMS implantation, and to expand its application in other indications.
Collapse
Affiliation(s)
- Yu Mo She
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Nan Ge
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang, China
| |
Collapse
|
3
|
She YM, Ge N. Diagnostic value of endoscopic ultrasonography in pelvic masses with bowel involvement. Therap Adv Gastroenterol 2023; 16:17562848231163414. [PMID: 37153498 PMCID: PMC10161300 DOI: 10.1177/17562848231163414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Accepted: 02/26/2023] [Indexed: 05/09/2023] Open
Abstract
Benign and malignant pelvic masses with or without intestinal invasion are common in women of childbearing age. Patients may have nonspecific symptoms and signs or experience no symptoms. Laparoscopic resection of pelvic masses is currently the mainstream treatment; therefore, accurate preoperative evaluation is not only essential for patients suspected of having intestinal invasion, but also extremely important for the selection of follow-up treatment. Procedures, including endoscopic ultrasonography (EUS), pelvic magnetic resonance imaging, abdominal computed tomography, vaginal ultrasonography, barium enema, and colonoscopy, aid in determining the presence, depth, and histology of the disease. In particular, the wide application and continuous developments in EUS techniques have improved the diagnostic accuracy for intestinal subepithelial and peripheral organ lesions. This article reviewed the clinical value of EUS in the diagnosis of benign and malignant pelvic masses with bowel involvement.
Collapse
Affiliation(s)
- Yu Mo She
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang, Liaoning Province, China
| | | |
Collapse
|
4
|
She YM, Ge N. The value of endoscopic ultrasonography for differential diagnosis in obstructive jaundice of the distal common bile duct. Expert Rev Gastroenterol Hepatol 2022; 16:653-664. [PMID: 35793397 DOI: 10.1080/17474124.2022.2098111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Obstructive jaundice is a common clinical disease of great significance; however, diagnosing it according to etiology, especially in patients with distal obstructive jaundice is difficult. The development of endoscopic ultrasonography has improved diagnostic methods. Endoscopic ultrasonography not only improves the accuracy of conventional endoscopic ultrasound technology in etiological diagnosis, but also offers several special endoscopic ultrasound technologies for diagnosing distal obstructive jaundice of the common bile duct. What's more, endoscopic ultrasonography can be used to treat distal obstructive jaundice of common bile duct. AREAS COVERED This review discusses the diagnostic value and applications of endoscopic ultrasonography for obstructive jaundice of the distal common bile duct. EXPERT OPINION This article summarizes the value of endoscopic ultrasonography in the etiological diagnosis, relevant treatment applications of distal obstructive jaundice and the limitations of endoscopic ultrasonography in some etiologies due to the lack of clear comparison with other imaging methods. We also provide new data for the future research direction of endoscopic ultrasonography in distal obstructive jaundice.
Collapse
Affiliation(s)
- Yu Mo She
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China
| | - Nan Ge
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China
| |
Collapse
|
5
|
Abstract
Equine myelin basic protein (MBP) has been isolated from spinal cord and shown to consist of a number of components (charge isomers) by alkaline-urea gel electrophoresis. Mass analyses of several of these components showed that each was posttranslationally modified and some have been identified. Component 1, the most cationic charge isomer, was sequenced by a combination of liquid chromatography and mass spectrometry of peptides obtained by proteolytic digestion. At 172 residues it is slightly larger than the bovine (169) and the human (170). A major difference between bovine and equine sequences was the replacement of AQGH (bovine residues 76-79) by SRDG (equine). A number of other replacements involving single amino acids were also found. Methylated arginine (residue 108 equine) was found as both the mono- and the dimethylated derivative and represents the first MS/MS evidence for this modification in any MBP.
Collapse
Affiliation(s)
- D D Wood
- Structural Biology and Biochemistry, The Hospital for Sick Children, Ont., M5G 1X8, Toronto, Canada
| | | | | | | | | |
Collapse
|
6
|
Burczynski FJ, Wang GQ, Elmadhoun B, She YM, Roberts MS, Standing KG. Hepatocyte [3H]-palmitate uptake: effect of albumin surface charge modification. Can J Physiol Pharmacol 2001; 79:868-75. [PMID: 11697746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
The role of plasma proteins on the cellular uptake of lipophilic substrates has perplexed investigators for many years. We tested the hypothesis that an ionic interaction between the protein-ligand complex and hepatocyte surface may be responsible for supplying more ligand to the cell for uptake. The surface-charged groups on albumin were modified to yield proteins having a range of isoelectric points (ALB, ALBs, ALBm, ALBe had values of 4.8-5.0, 4.5-4.7, 3.0-3.5, 8.4-8.6, respectively). [3H]-Palmitate uptake studies were performed with adult rat hepatocyte suspensions using similar unbound ligand fractions in the presence of the different binding proteins. Mass spectrometry, isoelectric focusing (pI), and heptane:water partitioning were used to determine protein molecular weight, pI, and protein-palmitate equilibrium binding constant, respectively. Hepatocyte [3H]-palmitate clearance in the presence of ALBs and ALBm were significantly lower (p < 0.05) than ALB, whereas [3H]-palmitate clearance in the presence of ALBe was significantly higher (p < 0.05) than ALB. The data were consistent with the notion that ionic interactions between extracellular protein-ligand complexes and the hepatocyte surface facilitate the uptake of long-chain fatty acids.
Collapse
Affiliation(s)
- F J Burczynski
- Department of Pharmacology, Faculty of Medicine, University of Manitoba, Winnipeg, Canada.
| | | | | | | | | | | |
Collapse
|
7
|
Burczynski FJ, Wang GQ, Elmadhoun B, She YM, Roberts MS, Standing KG. Hepatocyte [3H]-palmitate uptake: effect of albumin surface charge modification. Can J Physiol Pharmacol 2001. [DOI: 10.1139/y01-072] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The role of plasma proteins on the cellular uptake of lipophilic substrates has perplexed investigators for many years. We tested the hypothesis that an ionic interaction between the proteinligand complex and hepatocyte surface may be responsible for supplying more ligand to the cell for uptake. The surface-charged groups on albumin were modified to yield proteins having a range of isoelectric points (ALB, ALBs, ALBm, ALBe had values of 4.85.0, 4.54.7, 3.03.5, 8.48.6, respectively). [3H]-Palmitate uptake studies were performed with adult rat hepatocyte suspensions using similar unbound ligand fractions in the presence of the different binding proteins. Mass spectrometry, isoelectric focusing (pI), and heptane : water partitioning were used to determine protein molecular weight, pI, and protein-palmitate equilibrium binding constant, respectively. Hepatocyte [3H]-palmitate clearance in the presence of ALBs and ALBm were significantly lower (p < 0.05) than ALB, whereas [3H]-palmitate clearance in the presence of ALBe was significantly higher (p < 0.05) than ALB. The data were consistent with the notion that ionic interactions between extracellular proteinligand complexes and the hepatocyte surface facilitate the uptake of long-chain fatty acids.Key words: uptake, long-chain fatty acid, hepatic, protein, albumin, surface charge, facilitation, ionic interaction.
Collapse
|
8
|
She YM, Haber S, Seifers DL, Loboda A, Chernushevich I, Perreault H, Ens W, Standing KG. Determination of the complete amino acid sequence for the coat protein of brome mosaic virus by time-of-flight mass spectrometry. Evidence for mutations associated with change of propagation host. J Biol Chem 2001; 276:20039-47. [PMID: 11274180 DOI: 10.1074/jbc.m100189200] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Time-of-flight mass spectrometry (TOFMS) has been applied to determine the complete coat protein amino acid sequences of a number of distinct brome mosaic virus (BMV) isolates. Ionization was carried out by both electrospray ionization and matrix-assisted laser desorption/ionization (MALDI). After determining overall coat protein masses, the proteins were digested with trypsin or Lys-C proteinases, and the digestion products were analyzed in a MALDI QqTOF mass spectrometer. The N terminus of the coat protein was found to be acetylated in each BMV isolate analyzed. In one isolate (BMV-Valverde), the amino acid sequence was identical to that predicted from the cDNA sequence of the "type" isolate, but deviations from the predicted amino acid sequence were observed for all the other isolates analyzed. When isolates were propagated in different host taxa, modified coat protein sequences were observed in some cases, along with the original sequence. Sequencing by TOFMS may therefore provide a basis for monitoring the effects of host passaging on a virus at the molecular level. Such TOFMS-based analyses assess the complete profiles of coat protein sequences actually present in infected tissues. They are therefore not subject to the selection biases inherent in deducing such sequences from reverse-transcribed viral RNA and cloning the resulting cDNA.
Collapse
Affiliation(s)
- Y M She
- Department of Physics & Astronomy, University of Manitoba, Winnipeg, MB R3T 2N2, Canada
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Seifers DL, Salomon R, Marie-Jeanne V, Alliot B, Signoret P, Haber S, Loboda A, Ens W, She YM, Standing KG. Characterization of a novel potyvirus isolated from maize in Israel. Phytopathology 2000; 90:505-13. [PMID: 18944557 DOI: 10.1094/phyto.2000.90.5.505] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
A potyvirus (proposed name of Zea mosaic virus [ZeMV]) isolated from maize in Israel was analyzed by serology, sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) of capsid proteins, symptomatology, and sequencing. Parts of the nuclear inclusion b, coat protein, and 3' regions were sequenced; the amino acid sequence of ZeMV capsid was determined by time-of-flight mass spectrometry (TOFMS). The results of these analyses were compared with those of similar analyses of the following potyviruses: Maize dwarf mosaic virus (MDMV), Sugarcane mosaic virus strain MDB (SCMV-MDB), Johnsongrass mosaic virus(JGMV), Sorghum mosaic virus (SrMV), and an isolate of MDMV from Israel. Indirect enzyme-linked immunosorbent assay using ZeMV antiserum detected only ZeMV, and reciprocal tests using MDMV, JGMV, or SrMV antisera failed to detect ZeMV. ZeMV cross-reacted weakly when SCMV-MDB antiserum was used. The mass of ZeMV capsid was determined to be 36,810 Da by SDS-PAGE and 34,216 Da by TOFMS. The ZeMV systemically infected johnsongrass (Sorghum halepense), but did not infect oat (Avena sativa), pearl millet (Pennisetum glaucum), barley (Hordeum vulgare), or rye (Secale cereale). Necrosis was caused in 19 sorghum lines by SrMV, in 15 by ZeMV, in 14 by MDMV, and in 5 by JGMV and SCMV-MDB. The nucleic acid and amino acid sequences of ZeMV clearly showed that it is not a strain of JGMV, MDMV, SCMV, or SrMV.
Collapse
|
10
|
Seifers DL, Harvey TL, Haber S, She YM, Chernushevich I, Ens W, Standing KG. Natural Infection of Sorghum by Foxtail Mosaic Virus in Kansas. Plant Dis 1999; 83:905-912. [PMID: 30841071 DOI: 10.1094/pdis.1999.83.10.905] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Sorghum (Sorghum bicolor) was infected by a mechanically transmissible, flexuous, rod-shaped virus. Antiserum made against the purified virus reacted specifically in enzyme-linked immunosorbent assay to the virus and to the potexvirus foxtail mosaic virus (FoMV), indicating that the sorghum virus was an isolate of FoMV. Comparison of the sorghum isolate (H93) to FoMV PV 139 showed that H93 differed biologically by causing severe symptoms in sorghum, not readily infecting certain barley lines, and causing only faint symptoms in barley. At the molecular level, the capsid of H93 had a mass of 23.9 kDa and 217 amino acid residues compared with 23.7 kDa and 215 residues previously reported for the nucleic acid sequence of FoMV. The amino acid sequences of the two viruses were greater than 96% identical. They varied by having four substitutions, one deletion, and three insertions between residues 66 and 67. This is the first report of natural infection of sorghum by FoMV, thus extending its host range among cereal crops.
Collapse
Affiliation(s)
- Dallas L Seifers
- Associate Professor, Kansas State University, Agricultural Research Center-Hays 67601-9228
| | - Tom L Harvey
- Professor, Department of Entomology, Kansas State University, Manhattan 66506
| | - Steve Haber
- Research Scientist, Cereal Research Center, Agriculture & Agri-Food Canada, 195 Dafoe Road, Winnipeg, Manitoba, Canada
| | | | | | - Werner Ens
- Professor, Department of Physics, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Kenneth G Standing
- Professor, Department of Physics, University of Manitoba, Winnipeg, Manitoba, Canada
| |
Collapse
|