1
|
Periprosthetic fracture following arthroplasty for femoral neck fracture: is a cemented stem protective? EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:1927-1935. [PMID: 38462554 DOI: 10.1007/s00590-023-03830-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 12/28/2023] [Indexed: 03/12/2024]
Abstract
BACKGROUND Periprosthetic femoral fractures (PFF) carry significant morbidity following arthroplasty for femoral neck fracture (FNF). This study assessed fracture complications following arthroplasty for FNF and the effect of cement fixation of the femoral component on intraoperative and post-operative PFF. METHODS Between February 2014 and September 2021, 740 patients with a FNF who underwent arthroplasty were analyzed for demographics, surgical management, use of cement for fixation of the femoral component, and subsequent PFF. Variables were compared with Mann-Whitney or Chi-square as appropriate. Multivariate logistic regression was used to assess independent risk factors associated with intraoperative or post-operative PFF. RESULTS There were 163 THAs (41% cemented) and 577 HAs (95% cemented). There were 28 PFFs (3.8%): 18 post-operative and 10 intraoperative. Fewer post-operative PFFs occurred with cemented stems (1.63% vs. 6.30%, p = 0.002). Mean time from surgery to presentation with post-operative PFF was 14 months (0-45 months). Mean follow-up time was 10.3 months (range: 0-75.7 months). In multivariate regression, use of cement and THA was independently associated with decreased post-operative PFF (cement: OR 0.112, 95% CI 0.036-0.352, p < 0.001 and THA: OR 0.249, 95% CI 0.064-0.961, p = 0.044). More intraoperative fractures occurred during THA (3.68% vs. 0.69%, p = 0.004) and non-cemented procedures (5.51% vs. 0.49%, p < 0.001). In multivariate regression, use of cement was protective against intraoperative fracture (OR 0.100, CI 0.017-0.571, p = 0.010). CONCLUSIONS In patients with a FNF treated with arthroplasty, cementing the femoral component is associated with a lower risk of intraoperative and post-operative PFF. Choice of procedure may be based on patient factors and surgeon preference.
Collapse
|
2
|
Total hip arthroplasty with femoral shortening osteotomy using polished cemented stem vs. modular cementless stem in patients with Crowe type IV developmental dysplasia of the hip. Arch Orthop Trauma Surg 2022; 143:3487-3493. [PMID: 35915263 DOI: 10.1007/s00402-022-04518-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Accepted: 06/12/2022] [Indexed: 11/02/2022]
Abstract
INTRODUCTION There is still little information regarding the advantages of a using a polished tapered stem for Crowe Type IV developmental dysplasia of the hip (DDH). This study aimed to investigate the mid-term clinical and radiological outcomes of primary total hip arthroplasty (THA) with femoral shortening osteotomy using modular and polished tapered stems and to compare the results between the modular and polished tapered stems. MATERIALS AND METHODS This retrospective review included 32 patients (37 hips) with Crowe type IV DDH who underwent primary THA with femoral shortening osteotomy using a modular stem (cementless group, 14 hips) or a polished tapered stem (cement group, 23 hips) between 1996 and 2018. Clinical data and radiographic assessments were reviewed to analyze the differences between the two groups. RESULTS The mean duration of patient follow-up of the cementless group (134.4 months) was longer than that of the cement group (75.5 months). There were no differences in clinical results, time of bone union, and survival rate between the two groups. However, the cementless group exhibited a higher ratio of intraoperative fracture and thinning of cortical bone including stress shielding, medullary changes, stem alignment changes, and osteolysis, compared to the cement group. CONCLUSIONS The findings of this study suggest that THA with femoral shortening osteotomy using both cemented and modular stems can provide satisfactory results. However, considering the occurrence of intraoperative fracture and radiographic analysis in the current study, the cement stem may have an advantage for patients with bone fragility and deterioration in bone quality.
Collapse
|
3
|
Management and outcomes of femoral periprosthetic fractures at the hip : data from the characteristics, outcomes and management of periprosthetic fracture service evaluation (COMPOSE) cohort study. Bone Joint J 2022; 104-B:997-1008. [PMID: 35909379 DOI: 10.1302/0301-620x.104b8.bjj-2021-1682.r1] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The aim of this study was to describe the management and associated outcomes of patients sustaining a femoral hip periprosthetic fracture (PPF) in the UK population. METHODS This was a multicentre retrospective cohort study including adult patients who presented to 27 NHS hospitals with 539 new PPFs between 1 January 2018 and 31 December 2018. Data collected included: management strategy (operative and nonoperative), length of stay, discharge destination, and details of post-treatment outcomes (reoperation, readmission, and 30-day and 12-month mortality). Descriptive analysis by fracture type was performed, and predictors of PPF management and outcomes were assessed using mixed-effects logistic regression. RESULTS In all, 417 fractures (77%) were managed operatively and 122 (23%) conservatively. The median time to surgery was four days (interquartile range (IQR) 2 to 7). Of those undergoing surgery, 246 (59%) underwent revision and/or fixation and 169 (41%) fixation alone. The surgical strategy used differed by Unified Classification System for PPF type, with the highest rate of revision in B2/B3 fractures (both 77%, 176/228 and 24/31, respectively) and the highest rate of fixation alone in B1- (55/78; 71%) and C-type (49/65; 75%) fractures. Cemented stem fixation (odds ratio (OR) 2.66 (95% confidence interval (CI) 1.42 to 4.99); p = 0.002) and B2/B3 fracture type (OR 7.56 (95% CI 4.14 to 13.78); p < 0.001) were predictors of operative management. The median length of stay was 15 days (IQR 9 to 23), 12-month reoperation rate was 5.6% (n = 30), and 30-day readmission rate was 8.4% (n = 45). The 30-day and 12-month mortality rates were 5.2% (n = 28) and 21.0% (n = 113). Nonoperative treatment, older age, male sex, admission from residential or nursing care, and sustaining the PPF around a revision prosthesis were significant predictors of an increased 12-month mortality. CONCLUSION Femoral hip PPFs have mortality, reoperation, and readmission rates comparable with hip fracture patients. However, they have a longer wait for surgery, and surgical treatment is more complex. There is a need to create a national framework for data collection for this heterogeneous group of patients in order to understand the outcomes of different approaches to treatment. Cite this article: Bone Joint J 2022;104-B(8):997-1008 .
Collapse
|
4
|
Long-term survival of fully cemented stem in re-revision total knee arthroplasty performed on femur with diaphyseal deformation due to implant loosening. INTERNATIONAL ORTHOPAEDICS 2022; 46:1521-1527. [PMID: 35471610 DOI: 10.1007/s00264-022-05412-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Accepted: 04/18/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE The study aims to analyze long-term clinical and radiographic results, and survival of re-revision total knee arthroplasty (TKA) using fully cemented stems performed on femurs with diaphyseal deformation. METHODS Thirty-seven re-revision TKAs using fully cemented stems performed in femoral diaphyseal deformations, characterized as diaphyseal canal enlargement and cortex deformation due to aseptic loosening of previously implanted stems, between 2003 and 2015 were retrospectively reviewed. The mean follow-up period was 10.0 years. Clinically, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and range of motion (ROM) were evaluated. Radiographically, mechanical axis (MA) and component positions were measured. Complications and survival rates were also analyzed. RESULTS Clinically, the WOMAC significantly improved at final follow-up (61.2 vs 47.2, p < 0.001), but not the ROM (95.5 vs 102.5, p = 0.206). Radiographically, the MA and component positions were appropriate, with no changes in component positions from immediately post-operative to final follow-up, but with MA change from varus 2.9° to 3.7° (p = 0.020). Two cases (5.4%) with history of previous infections developed periprosthetic joint infection (PJI). Debridement with polyethylene insert exchange following antibiotic suppression were performed in those cases because of concern for difficult implant-cement removal. The five and ten year survival rates were 100% and 93.2%, respectively. CONCLUSION Fully cemented stems are viable in providing long-term satisfactory survival after re-revision TKA in patients with femoral diaphyseal deformation. However, it should be used carefully for those with previous infections.
Collapse
|
5
|
High rates of implant fracture of a generic polished tapered femoral stem. Hip Int 2022; 32:99-105. [PMID: 32459520 DOI: 10.1177/1120700020925739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVES Cemented polished tapered stems have demonstrated excellent long-term outcomes. Based on this concept, many generic tapered stems have been released into the market. The aim of this study was to evaluate implant-related complications of 1 specific stem design. METHODS Between 2010 and 2017, 315 total hip replacements were performed using a Fortress stem (Biotechni, La Ciotat, France). Patient records and radiology were retrospectively reviewed for implant-related complications. A failure analysis was performed on the failed Fortress stems in order to determine the cause of premature failure. RESULTS 7 (2.2%) patients sustained a fracture of the neck of the implant after a mean of 5 years (range 50-81 months). All fractures were atraumatic, originating at the introducer inlet of the stem. All fractured occurred in obese patients (BMI >33 kg/m2) with a small sized prosthesis. Of these, there were 5 135° and 2 125° stems. Fracture risk was 23% (7/30) for patients with a small sized stem and a BMI >30 kg/m2. All cases were revised using a cement-in-cement technique or a cementless modular revision stem. Failure analysis on the retrieved stems revealed a stress riser at the bottom of the introducer inlet. CONCLUSIONS An alarmingly high rate of early implant fractures was seen using this specific type of cemented stem, particularly when using smaller implant sizes in obese patients. Although based on a proven design, a specific modification led to a stress riser in the neck area, which resulted in a high incidence of implant failure. This series underlines the importance of a stepwise introduction into the market of new orthopaedic devices even when based on established concepts. Generic stems may not behave as the original stem upon which it was designed.
Collapse
|
6
|
Reliability and validity of the Unified Classification System for postoperative periprosthetic femoral fractures around cemented polished taper-slip stems. Bone Joint J 2021; 103-B:1339-1344. [PMID: 34334039 DOI: 10.1302/0301-620x.103b8.bjj-2021-0021.r1] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
AIMS This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems. METHODS Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss' kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs. RESULTS Interobserver reliability percentage agreement was 58.5% and the overall kappa value was 0.442 (moderate agreement). Lowest kappa values were seen for type B fractures (0.095 to 0.360). The mean intraobserver reliability kappa value was 0.672 (0.447 to 0.867), indicating substantial agreement. Validity percentage agreement was 65.7% and the mean kappa value was 0.300 (0.160 to 0.4400) indicating only fair agreement. CONCLUSION This study demonstrates that the UCS is unsatisfactory for the classification of PFFs around PTS stems, and that it has considerably lower reliability and validity than previously described for other stem types. Radiological PTS stem loosening in the presence of PFF is poorly defined and formal intraoperative testing of stem stability is recommended. Cite this article: Bone Joint J 2021;103-B(8):1339-1344.
Collapse
|
7
|
Abstract
AIMS To achieve the functional benefits of the direct anterior (DA) approach and the fixation benefits of cemented replacement, this study combined the two techniques posing the following questions: does the limited access of the DA approach adversely affect the cement technique?; and does such a cementing technique reduce the incidence of cementless complications? METHODS A consecutive series of 341 patients (360 hips) receiving the DA approach between 2016 and 2018 were reviewed. There were 203 cementless stems and 157 cemented stems. Mean age was 75 years (70 to 86) in the cementless group and 76 years (52 to 94) in the cemented group, with 239 (70%) females in the whole series. Femoral complications were compared between the two groups. Mean follow-up was 1.5 years (0.1 to 4.4) for patients in the cementless group and 1.3 years (0.0 to 3.9) for patients in the cemented group. RESULTS The cementless group had a higher rate of femoral complications (8 vs 0; p = 0.011). There were two loose stems and six fractures, all requiring revision. Fractures occurred a mean 14.5 days (2 to 31) postoperatively and loosening at 189 days and 422 days postoperatively. Femoral cementing can be done using the DA approach safely and reduces the number of complications compared with a contemporary cementless series. CONCLUSION A higher rate of early fractures and loosening occurred with cementless stems. This was not observed in our cemented stem cohort and cementing was safely accomplished through the DA approach. The modern femoral cementing process with the DA approach does not add to surgical complexity or time, has fewer early complications, and is a safer option for older patients compared to cementless femoral arthroplasties. Cite this article: Bone Joint J 2021;103-B(7 Supple B):33-37.
Collapse
|
8
|
Risk factors influencing fracture characteristics in postoperative periprosthetic femoral fractures around cemented stems in total hip arthroplasty : a multicentre observational cohort study on 584 fractures. Bone Jt Open 2021; 2:466-475. [PMID: 34233455 PMCID: PMC8325979 DOI: 10.1302/2633-1462.27.bjo-2021-0027.r1] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Aims This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty. Methods Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type. Results A total of 584 cases were included. Median age was 79.1 years (interquartile range 72.0 to 86.0), 312 (53.6%) patients were female, and 495 (85.1%) stems were PTS. The commonest UCS grade was type B1 (278, 47.6%). The most common AO/OTA type was spiral (352, 60.3%). Metaphyseal split fractures occurred only with PTS stems with an incidence of 10.1%. Male sex was associated with a five-fold reduction in odds of a type C fracture (OR 0.22 (95% CI 0.12 to 0.41); p < 0.001) compared to a type B fracture. CB stems were associated with significantly increased odds of transverse fracture (OR 9.51 (95% CI 3.72 to 24.34); p < 0.001) and wedge fracture (OR 3.72 (95% CI 1.16 to 11.95); p = 0.027) compared to PTS stems. Both UCS grade and AO/OTA type differed significantly (p < 0.001 and p = 0.001, respectively) between the revision and fixation groups but a similar proportion of B1 fractures underwent revision compared to fixation (45.3% vs 50.6%). Conclusion The commonest fracture types are B1 and spiral fractures. PTS stems are exclusively associated with metaphyseal split fractures, but their incidence is low. Males have lower odds of UCS grade C fractures compared to females. CB stems have higher odds of bending type fractures (transverse and wedge) compared to PTS stems. There is considerable variation in practice when treating B1 fractures around cemented stems. Cite this article: Bone Jt Open 2021;2(7):466–475.
Collapse
|
9
|
Prosthetic Neck Fracture in Exeter V40 Stems: A Report of Two Cases and Review of Literature. Arthroplast Today 2021; 7:105-108. [PMID: 33521205 PMCID: PMC7818608 DOI: 10.1016/j.artd.2020.11.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Revised: 11/25/2020] [Accepted: 11/27/2020] [Indexed: 12/02/2022] Open
Abstract
This report contains 2 acute fractures of the Exeter V40 stem with 2 different types of neck fracture, one at the subcapital level and another at the base of the neck. A review of relevant literature provides an insight into a similar pattern of failures reported in a certain subset of cases. We hypothesize that for high-BMI cases, attention to proper preoperative templating is mandatory. The operating surgeon should try to restore offset without having to use a long head in this subgroup of patients. We feel that trying to compensate for the offset with a long head may lead to high-stress concentration in the neck. This, in turn, may be responsible for the failure of the stem, as seen in the reported cases. We advocate, based on the literature, the need to recreate the offset carefully with as big a stem as possible to avoid these unique and rare complications. Reducing such failures may further improve the overall survivorship of the V40 Exeter stem.
Collapse
|
10
|
Hybrid stems are superior to cemented stems in revision total knee arthroplasty: a systematic review and meta-analysis of recent comparative studies. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2020; 31:131-141. [PMID: 32737569 DOI: 10.1007/s00590-020-02752-w] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Accepted: 07/25/2020] [Indexed: 11/26/2022]
Abstract
INTRODUCTION The demand for revision total knee arthroplasty (TKA) has grown significantly in recent years. The two major fixation methods for stems in revision TKA include cemented and 'hybrid' fixation. We explore the optimal fixation method using data from recent, well-designed comparative studies. METHODS We performed a systematic review of comparative studies published within the last 10 years with a minimum follow-up of 24 months. To allow for missing data, a random-effects meta-analysis of all available cases was performed. The odds ratio (OR) for the relevant outcome was calculated with 95% confidence intervals. The effects of small studies were analyzed using a funnel plot, and asymmetry was assessed using Egger's test. The primary outcome measure was all-cause failure. Secondary outcome measures included all-cause revision, aseptic revision and radiographic failure. RESULTS There was a significantly lower failure rate for hybrid stems when compared to cemented stems (p = 0.006) (OR 0.61, 95% CI 0.42-0.87). Heterogeneity was 4.3% and insignificant (p = 0.39). There was a trend toward superior hybrid performance for all other outcome measures including all-cause re-revision, aseptic re-revision and radiographic failure. CONCLUSION Recent evidence suggests a significantly lower failure rate for hybrid stems in revision TKA. There is also a trend favoring the use of hybrid stems for all outcome variables assessed in this study. This is the first time a significant difference in outcome has been demonstrated through systematic review of these two modes of stem fixation. We therefore recommend the use, where possible, of hybrid stems in revision TKA.
Collapse
|
11
|
Abstract
INTRODUCTION Breakage of the femoral stem component of a total hip replacement is now uncommon but continues to be seen with certain stem designs and in certain patient groups. Data previously published on this topic has been limited, either gathered from a single surgeon or centre, or included only a single stem design. METHODS We reviewed the data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), identified and analysed 143 stem breakages over a period of 16 years, covering 44 different stem designs. RESULTS Our data confirms previously published findings that risk factors for stem breakage include patient age at implantation of under 70, male gender, as well as the use of exchangeable necks. We found no association with initial diagnosis, or type of acetabular component implanted. We did however also find, excluding exchangeable neck designs, that after 4.5 years a cemented stem had a significantly higher risk of breakage then a cementless stem. DISCUSSION To our knowledge this is the 1st paper to suggest cemented fixation as a specific risk factor for stem breakage. The analysis of rare complications such as stem breakage is only possible through large data collection systems such as the AOANJRR. Whilst there have been recent advances in materials and manufacturing techniques, we recommend that surgeons are aware of all the specific risks when considering implant choices for individual patients.
Collapse
|
12
|
Postoperative migration of the anatomical and functional anteversion angle following total hip arthroplasty with a well-fixed cemented femoral component with line-to-line implantation. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2020; 30:1067-1074. [PMID: 32314066 DOI: 10.1007/s00590-020-02671-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Accepted: 04/07/2020] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Little is known about the association between well-fixed polished tapered cemented stems (PTCS) implanted by the line-to-line technique and changes of stem migration, or the change of functional anteversion of the femur after total hip arthroplasty (THA). MATERIALS AND METHODS This retrospective study included 422 two-stage bilateral primary THAs performed using PTCS implanted by the line-to-line technique. CT scans were made on both the target side (first postoperative CT) and on the contralateral side (second postoperative CT) 1 week postoperatively. The mean follow-up was 7.8 months. CT data for each scan were transferred to 3D template software (Zed hip, Lexi, Japan). The postoperative changes of anatomical stem anteversion (ASA), functional femoral anteversion (FFA), and stem subsidence were evaluated. RESULTS A total of 20 THAs with CT scans were available on 3D template software. The ASA and the FFA had migrated - 0.68° ± 0.62° and - 5.5° ± 9.7°, respectively, over the follow-up period. A significant positive correlation was observed between the change of subsidence and ASA (r2 = 0.34, p = 0.007), between the FFA on the second postoperative CT and ASA on the first postoperative CT (r2 = 0.26, p = 0.02) and between the FFA on the second postoperative CT and FFA on the first postoperative CT (r2 = 0.52, p = 0.0003). CONCLUSION This study indicates that the change in axial rotation of a PTCS implanted by the line-to-line technique was less than that reported by other studies and the preoperative external rotation contracture was substantially improved after THA.
Collapse
|
13
|
A simple angle-measuring instrument for measuring cemented stem anteversion during total hip arthroplasty. BMC Musculoskelet Disord 2020; 21:113. [PMID: 32075628 PMCID: PMC7031998 DOI: 10.1186/s12891-020-3142-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2019] [Accepted: 02/17/2020] [Indexed: 11/30/2022] Open
Abstract
Background During total hip arthroplasty (THA), the accurate placement of the femoral components is an important determinant of the success of the procedure. This study assessed the accuracy of cemented stem placement using a new angle-measuring instrument. The primary objective was to investigate the accuracy of the intraoperative measurements of cemented stem anteversion obtained using the angle-measuring instrument. Our secondary objective was to evaluate the accuracy of stem positioning performed using the angle-measuring instrument. Methods We compared the intraoperative stem anteversion measurements obtained using the angle-measuring instrument with postoperative stem anteversion measurements obtained using computed tomography in 149 hips (measurement accuracy). We also compared the target angle and postoperative stem anteversion in 105 hips (implantation accuracy). Results The mean amount of intraoperative stem anteversion was 37.9° ± 10.1°, and the mean amount of postoperative stem anteversion was 37.0° ± 10.4°. The mean measurement accuracy was 0.9° ± 6.1°, and the absolute measurement accuracy was 4.9° ± 3.7°. The correlation coefficient for the relationship between the intraoperative and postoperative stem anteversion measurements was 0.824 (p = 0.000). The mean amount of target angle was 37.4° ± 7.6°, and the mean amount of postoperative stem anteversion was 35.9° ± 9.1°. The mean implantation accuracy was 1.4° ± 5.6°, and the mean absolute implantation accuracy was 4.3° ± 3.6°. The correlation coefficient for the relationship between the target angle and postoperative stem anteversion was 0.795 (p = 0.000). Conclusions The angle-measuring instrument measured intraoperative stem anteversion accurately, and cemented stem was implanted accurately during THA with the angle-measuring instrument.
Collapse
|
14
|
Abstract
INTRODUCTION Total hip arthroplasty in patients with altered anatomy of the hip and femur, such as in congenital dysplasia of the hip, is challenging and often requires specially designed stems. Müller straight stems have shown excellent long-term results; however, long-term data on the analogous cemented Müller CDH stem are still missing. The aim of this study was to analyze long-term survival, identify potential risk factors for aseptic loosening, and analyze radiological outcome of the cemented Müller CDH stems. MATERIALS AND METHODS Between 01/1985 and 06/2005, 95 Müller CDH stems (Zimmer, Winterthur, Switzerland) made up of 3 different materials were cemented using 2 different bone cements: 38 of stainless steel/high-viscosity cement, 31 of a cobalt-chrome-based alloy (CoCr)/low-viscosity cement, and 26 of a titanium-based alloy (Ti)/low-viscosity cement. All patients had a prospective clinical and radiological follow-up according to the standards of our institution. The cumulative incidence for revision of the stem was calculated using a competing risk model. To identify demographic and implant-related risk factors for aseptic loosening of the stem, a multivariate regression model for competing risks was performed. RESULTS The cumulative risk of revision at 15 years was 12.5% (95% CI 6.6-20.5%) for aseptic loosening of the stem as endpoint, with marked differences for the various stem materials used: stainless steel 2.7% (0.2-12.3%), CoCr 12.9% (4.0-27.3%), and Ti 24.5% (9.6-43.1%). Regression modeling revealed that Ti stems in combination with low-viscosity cement (HR 10.2) and implantation with an axis deviation greater than 3° (HR 3.8) are risk factors for aseptic loosening. CONCLUSIONS Long-term survival of the cemented Müller CDH stem is comparable to other Müller-type straight stems and uncemented implants. Similar to the original Ti Müller straight stem, the Ti Müller CDH stem also showed an increased risk for aseptic loosening and should, therefore, no longer be used.
Collapse
|
15
|
Abstract
The results of modern cemented and uncemented total hip arthroplasties are outstanding and both systems have their advantages and disadvantages. This paper aims to examine the designs of different types of prostheses, some history behind their development and the reported results. Particular emphasis is placed on cemented stem design and the details of cementing technique.
Collapse
|
16
|
Comparative Study of Bipolar Hemiarthroplasty for Femur Neck Fractures Treated with Cemented versus Cementless Stem. Hip Pelvis 2016; 28:208-216. [PMID: 28097110 PMCID: PMC5240311 DOI: 10.5371/hp.2016.28.4.208] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2016] [Revised: 10/25/2016] [Accepted: 11/01/2016] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To compare and analyze clinical and radiologic outcomes of cemented versus cementless bipolar hemiarthroplasty for treatment of femur neck fractures. MATERIALS AND METHODS A total of 180 patients aged 65 years and over older who underwent bipolar hemiarthroplasty for treatment of displaced femur neck fractures (Garden stage III, IV) from March 2009 to February 2014 were included in this study. Among the 180 patients, 115 were treated with cemented stems and 65 patients with cementless stems. Clinical outcomes assessed were: i) postoperative ambulatory status, ii) inguinal and thigh pain, and iii) complications. The radiologic outcome was femoral stem subsidence measured using postoperative simple X-ray. RESULTS The cemented group had significantly lower occurrence of complications (postoperative infection, P=0.04) compared to the cementless group. There was no significant difference in postoperative ambulatory status, inguinal and thigh pain, and femoral stem subsidence. CONCLUSION For patients undergoing bipolar hemiarthroplasty, other than complications, there was no statistically significant difference in clinical or radiologic outcomes in our study. Selective use of cemented stem in bipolar hemiarthroplasty may be a desirable treatment method for patients with poor bone quality and higher risk of infections.
Collapse
|
17
|
Triple taper stem design shows promising fixation and bone remodelling characteristics: radiostereometric analysis in a randomised controlled trial. Bone Joint J 2015; 97-B:755-61. [PMID: 26033054 DOI: 10.1302/0301-620x.97b6.34736] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Cemented femoral stems with force closed fixation designs have shown good clinical results despite high early subsidence. A new triple-tapered stem in this category (C-stem AMT) was introduced in 2005. This study compares this new stem with an established stem of similar design (Exeter) in terms of migration (as measured using radiostereometric analysis), peri-prosthetic bone remodelling (measured using dual energy x-ray densitometry, DXA), Oxford Hip Score, and plain radiographs. A total of 70 patients (70 hips) with a mean age of 66 years (53 to 78) were followed for two years. Owing to missing data of miscellaneous reasons, the final analysis represents data from 51 (RSA) and 65 (DXA) patients. Both stems showed a typical pattern of migration: Subsidence and retroversion that primarily occurred during the first three months. C-stem AMT subsided less during the first three months (p = 0.01), before stabilising at a subsidence rate similar to the Exeter stem from years one to two. The rate of migration into retroversion was slightly higher for C-stem AMT during the second year (p = 0.03). Whilst there were slight differences in movement patterns between the stems, the C-stem AMT exhibits good early clinical outcomes and displays a pattern of migration and bone remodelling that predicts good clinical performance.
Collapse
|
18
|
Titanium-titanium modular neck for primary THA. Result of a prospective series of 170 cemented THA with a minimum follow-up of 5 years. Orthop Traumatol Surg Res 2015; 101:137-42. [PMID: 25698098 DOI: 10.1016/j.otsr.2014.12.013] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2012] [Revised: 11/26/2014] [Accepted: 12/02/2014] [Indexed: 02/02/2023]
Abstract
BACKGROUND Although they have been in use since the end of the 1980s, modular titanium neck components are associated with a risk of wear or fracture, and their safety has recently become a subject of debate and has never been evaluated in a consecutive series of patients. The goal of this study was to evaluate: revision-free survival of these implants after a minimum follow-up of 5 years; clinical and radiographic results; and the potential complications associated with the use of modular titanium neck components. HYPOTHESIS The use of titanium modular neck on cemented titanium THA is safe at a minimum follow-up of 5 years. PATIENTS AND METHODS Between January 2006 and December 2008, we prospectively followed 170 patients (170 hips) who underwent primary anatomical THA with a modular cemented titanium stem design implant. The indications were unilateral THA for primary (n=160) or secondary (n=10) hip osteoarthritis (aseptic osteonecrosis of the femoral head or hip dysplasia). Mean age of patients was 75.4±5.8 years old (52-85), and mean BMI was 26.1±4.5 kg/m(2) (16.6-42.1). Patients were operated on by a modified Watson-Jones anterolateral approach based on preoperative 2D planning. All patients underwent annual clinical and radiological follow-up by an independent observer. RESULTS At a mean follow-up of 71±8 months (60-84), 5 patients died and 7 were lost to follow-up. There was no revision of THA after a maximum follow-up of 84 months. The Harris score improved significantly from 50.4±11.3 (0-76) preoperatively to 84.5±15.2 (14-100) at the final follow-up. There was no difference in postoperative femoral offset or the position of the center of rotation compared to the opposite side. On the other hand, the neck-shaft angle (NSA) and limb length were corrected (2±5° [-11 to +14°] and 2.16±3.6 mm [-7.4 to +12.7 mm]) respectively. Fifteen patients (9%) had limb length discrepancies of more than 5 mm and 4 patients (2%) of more than 10 mm. There were no complications due to the modular implant design. DISCUSSION Our study suggests that the use of cemented titanium implants with a modular titanium stem is safe at a follow-up of 5 years. The modular design does not prevent limb length discrepancies but restores femoral offset. LEVEL OF EVIDENCE IV: prospective, non-comparative study.
Collapse
|