The effect of Fiber Optic RealShape technology on the reduction of radiation during complex endovascular surgery. J Vasc Surg 2024; 79:954-961. [PMID: 37931886 PMCID: PMC10960673 DOI: 10.1016/j.jvs.2023.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 10/28/2023] [Accepted: 11/01/2023] [Indexed: 11/08/2023]
Abstract
OBJECTIVE Despite the advantages that fenestrated endovascular aortic repair has over open repair, it is accompanied by the consequence of radiation exposure, which can result in long-term complications for both the patient and surgical staff. Fiber Optic RealShape (FORS) technology is a novel advancement that uses emitted light from a fiber optic wire and enables the surgeon to cannulate vessels in real time without live fluoroscopy. This technology has been implemented at select centers to study its effectiveness for cannulation of target vessels and its impact on procedural radiation. METHODS We collected prospective data on physician-modified endograft (PMEG) cases before and after the introduction of FORS technology. FORS PMEGs were matched with up to three conventional fluoroscopy cases by number of target vessels, inclusion of a bifurcated device below, aneurysm extent, and patient body mass index. The procedural radiation parameters were compared between these cohorts. Within the FORS cohort, we analyzed the rate of successful target vessel cannulation for all cases done with this technology (including cases other than PMEGs), and we compared the radiation between the cannulations using only FORS with those that abandoned FORS for conventional fluoroscopy. RESULTS Nineteen FORS PMEGs were able to be matched to 45 conventional fluoroscopy cases. Procedures that used FORS technology had significantly reduced total air kerma (527 mGy vs 964 mGy), dose area product (121 Gy∗cm2 vs 186 Gy∗cm2), fluoroscopy dose (72.1 Gy∗cm2 vs 132.5 Gy∗cm2), and fluoroscopy time (45 minutes vs 72 minutes). There was no difference in procedure length, total contrast, or digital subtraction angiography. Within FORS cases, 66% of cannulations were completed using only FORS. Cannulations using only FORS had significant reduction of navigation air kerma (5.0 mGy vs 26.5 mGy), dose area product (1.2 Gy∗cm2 vs 5.1 Gy∗cm2), and fluoroscopy time (0.6 minutes vs 2.3 minutes) compared with cannulations abandoning FORS for conventional fluoroscopy. CONCLUSIONS This study demonstrates the advantages of FORS for total procedural radiation as well as during individual cannulation tasks. The implementation of FORS for target vessel catheterization has the potential to decrease the total degree of radiation exposure for the patient and surgical staff during complex endovascular aortic surgeries.
Collapse
|
2
|
A novel plasmonic optical-fiber-based point-of-care test for periodontal MIP-1α detection. iScience 2023; 26:108539. [PMID: 38089574 PMCID: PMC10711496 DOI: 10.1016/j.isci.2023.108539] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 07/19/2023] [Accepted: 11/20/2023] [Indexed: 04/23/2024] Open
Abstract
The analysis of salivary biomarkers as expression of periodontal health conditions has been proposed as a useful aid to conventional diagnostic approaches. In this study, we present a point-of-care test (POCT) exploiting a surface plasmon resonance (SPR)-based optical biosensor to detect salivary macrophage inflammatory protein (MIP)-1α, a promising marker of periodontitis. A plastic optical fiber (POF) was suitably modified and functionalized by an antibody self-assembled monolayer against MIP-1α for plasmonic detection. The proposed SPR-POF biosensor showed high selectivity and very low limit of detection for MIP-1α of 129 fM (1.0 pg/mL) in phosphate-buffered saline and 346 fM (2.7 pg/mL) in saliva. As a proof of concept, this POCT was also able to discriminate between a periodontitis patient and a healthy subject. The obtained results support the future application of this technology for an on-site detection and real-time monitoring of periodontal health conditions for diagnostic and therapeutic purposes.
Collapse
|
3
|
Active-distributed temperature sensing dataset beneath a braided river. Data Brief 2023; 51:109756. [PMID: 38020435 PMCID: PMC10661649 DOI: 10.1016/j.dib.2023.109756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 10/29/2023] [Accepted: 10/30/2023] [Indexed: 12/01/2023] Open
Abstract
Braided rivers play a significant role in replenishing groundwater, but our understanding of how these recharge rates fluctuate over time remains limited. Traditional techniques for gauging groundwater recharge are ineffective for studying complex braided river systems due to their insufficient spatiotemporal resolution. To address this gap, active-distributed temperature sensing (A-DTS) was used. This method combines fiber optic temperature measurements with an active heat source, enabling quantification of groundwater fluxes. In this study, twelve consecutive A-DTS surveys were conducted on a 100 m long hybrid fiber optic cable to a depth of 5 m beneath the Waikirikiri Selwyn River. This experiment was conducted during a period of relatively stable river stage and flow, highlighting the effectiveness of using A-DTS to measure temporal changes in groundwater recharge.
Collapse
|
4
|
Sleep condition detection and assessment with optical fiber interferometer based on machine learning. iScience 2023; 26:107244. [PMID: 37496677 PMCID: PMC10366502 DOI: 10.1016/j.isci.2023.107244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 05/21/2023] [Accepted: 06/26/2023] [Indexed: 07/28/2023] Open
Abstract
The prevalence of sleep disorders has increased because of the fast-paced and stressful modern lifestyle, negatively impacting the quality of human life and work efficiency. It is crucial to address sleep problems. However, the current practice of diagnosing sleep disorders using polysomnography (PSG) has limitations such as complexity, large equipment, and low portability, hindering its practicality for daily use. To overcome these challenges, in this article an optical fiber sensor is proposed as a viable solution for sleep monitoring. This device offers benefits like low power consumption, non-invasiveness, absence of interference, and real-time health monitoring. We introduce the sensor with an optical fiber interferometer to capture ballistocardiography (BCG) and electrocardiogram (ECG) signals from the human body. Furthermore, a new machine learning method is proposed for sleep condition detection. Experimental results demonstrate the superior performance of this architecture and the proposed model in monitoring and assessing sleep quality.
Collapse
|
5
|
Initial single-center experience using Fiber Optic RealShape guidance in complex endovascular aortic repair. J Vasc Surg 2023; 77:975-981. [PMID: 36384183 DOI: 10.1016/j.jvs.2022.11.041] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 10/23/2022] [Accepted: 11/07/2022] [Indexed: 11/15/2022]
Abstract
OBJECTIVE In the present study, we have described the technical success using Fiber Optic RealShape (FORS) endovascular guidance and its effects on the overall procedural time and radiation usage during complex endovascular aortic repair (EVAR). METHODS Fenestrated and branched EVARs performed at a single center from 2017 to 2022 were prospectively studied. FORS-guided procedures were matched retrospectively 1:3 to non-FORS-guided procedures by the incorporated target arteries and body mass index. Technical success was defined as successful target vessel cannulation using FORS for the entirety of navigation (wire insertion to exchange for a stiff wire). The predictors of technical success were evaluated via logistic regression. The procedural times and radiation doses were compared between the matched cohorts using the Wilcoxon rank sum test. RESULTS A total of 21 FORS-guided procedures were matched to 61 non-FORS-guided procedures. A total of 95 FORS cannulations were attempted (87 for the visceral target artery and 8 for the bifurcate gate). Technical success was achieved in 81 cannulations (85%); 15 (16%) were completed without the use of live fluoroscopy. The univariate predictors of FORS technical success included <50% target artery stenosis, <50% target artery calcification, and the target vessel attempted (P < .05 for each). FORS failures were attributed to device material properties in six cases, device failure in two cases, and the wire/catheter combination in six. The use of FORS guidance was associated with shorter median procedural and fluoroscopy times and a lower dose area product and air kerma (P ≤ .0001 for each). CONCLUSIONS The results from our initial experience with FORS during complex EVAR, including our learning curve, has shown promise, with acceptable technical success and reductions in procedural times and radiation usage.
Collapse
|
6
|
Fiber-optic integrated aerodynamic three-hole vector probe for high-velocity flow field measurement. iScience 2022; 25:104402. [PMID: 35633936 PMCID: PMC9136669 DOI: 10.1016/j.isci.2022.104402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 04/26/2022] [Accepted: 05/10/2022] [Indexed: 12/04/2022] Open
Abstract
An integrated aerodynamic three-hole pressure probe (THP) based on a fiber-optic tip sensor array for high-velocity flow field vector measurement is developed and demonstrated in wind tunnel testing. The sensor array consisting of three miniature pressure fiber-tip sensors is integrated into three pressure conduits inside top area of the THP, which serves to mitigate pneumatic pressure loss and is expected for a more reliable analysis of flow characteristics. Fast real-time data acquisition is implemented by a compact self-developed multichannel white light interferometry (WLI) interrogator. Well-calibrated maps of the fiber-optic THP are developed in a subsonic free-jet wind tunnel to derive the velocity vectors in a yaw angular range of ±15° at Mach numbers of 0.2 Ma (∼70 m/s), 0.5 Ma (∼170 m/s), and 0.8 Ma (∼300 m/s) while related flow characteristics are analyzed. This work is desired to provide a potential candidate for turbomachinery experimental investigation in fluid mechanics community. Real-time measurement of high-velocity flow field vector Batch fabrication of miniature fiber-optic tip pressure sensors using MEMS technology Self-developed fiber-optic multichannel white light interferometry interrogator Feasibility verification of fiber-optic sensing system for flow field analysis
Collapse
|
7
|
Abstract
INTRODUCTION Steering light is relevant to many medical applications that require tissue illumination, sensing, or modification. To control the propagation direction of light beams, a great variety of innovative fiber-optic medical devices have been designed. AREAS COVERED This review provides a comprehensive overview of the patent literature on light beam control in fiber-optic medical devices. The Web of Science Derwent Innovation Index database was scanned, and 81 patents on fiber-optic devices published in the last 20 years (2001-2021) were retrieved and categorized based on the working principle to steer light (refraction/reflection, scattering, diffraction) and the design strategy that was employed (within fiber, at fiber end, outside fiber). EXPERT OPINION Patents describing medical devices were found for all categories, except for generating diffraction at the fiber end surface. The insight in the different designs reveals that there are still several opportunities to design innovative devices that can collect light at an angle off-axis, reduce the angular distribution of light, or split light into multiple beams.
Collapse
|
8
|
Dual-wavelength fiber-optic technique to assist needle cricothyroidotomy. Lasers Med Sci 2020; 36:571-582. [PMID: 32700050 PMCID: PMC7952284 DOI: 10.1007/s10103-020-03065-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Accepted: 06/09/2020] [Indexed: 11/25/2022]
Abstract
The traditional needle cricothyroidotomy procedure is performed blindly without any medical equipment. Complications including posterior tracheal wall perforation, accidental vessel puncture, and missed tracheal puncture are reported. Therefore, we proposed a dual-wavelength fiber-optic technique based on the technique of near-infrared spectroscopy to assist operators performing needle cricothyroidotomy in a swine model. We embedded optical fibers in a 16-gauge intravenous needle catheter. Real-time data were displayed on an oscilloscope, and we used the program to analyze the data immediately. The change of optical density corresponding to 690-nm and 850-nm wavelengths and hemoglobin parameters (HbO2 and Hb concentrations) was analyzed immediately using the program in the laptop. Unique and significant optical differences were presented in this experiment. We could easily identify every different tissue by the change of optical density corresponding to 690-nm and 850-nm wavelengths and hemoglobin parameters (HbO2 and Hb concentrations). Statistical method (Kruskal-Wallis H test) was used to compare differences in tissues at each time-point, respectively. The p values in every tissue in optical density change corresponding to 690 nm and 850 nm were all < 0.001. Furthermore, the p values in every tissue in Hb and HbO2 were also all < 0.001. The results were statistically significant. This is the first and novel study to introduce a dual-wavelength embedded fibers into a standard cricothyroidotomy needle. This proposed system might be helpful to provide us real-time information of the advanced needle tip to decrease possible complications.
Collapse
|
9
|
TiO 2-coated 2D photonic crystals for reflectometric determination of malachite green. Mikrochim Acta 2019; 186:844. [PMID: 31768658 DOI: 10.1007/s00604-019-3976-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Accepted: 10/25/2019] [Indexed: 01/26/2023]
Abstract
A "detect and destroy" strategy is reported for the spectroscopic determination and photocatalytic degradation of Malachite Green (MG) in aqueous solutions. The intensity of the reflection peak maxima from the TiO2-coated 2D-photonic crystal (PhC) at 633 nm wavelength undergoes a gradual decrease with increasing concentrations of MG. The determination of MG was readily achieved in the nanomolar range due to the quenching of the reflection intensity of the peak, measured using a fiber optic probe. The assay works in the 1.0 nM to 10 μM MG concentration range with a detection limit of 1.3 nM. The same TiO2-coated 2D-PhC surface can photocatalytically degrade MG in aqueous solutions under UV irradiation. The photocatalytic degradation in the presence of TiO2-coated 2D-PhC becomes evident as the blue color of MG changes to colorless with increasing irradiation time. The decrease in absorption is detected at 617 nm. It was found that the photocatalytic efficiency of TiO2 was synergistically enhanced in the presence of 2D-PhCs. It is concluded that each component of the TiO2-coated 2D-PhC system plays a key role in the detection and degradation of MG. Graphical abstractSchematic representation for reflectometric detection and photocatalytic degradation of hazardous Malachite Green dye using TiO2-coated two-dimensional photonic crystals.
Collapse
|
10
|
Hydrogel optical fibers for continuous glucose monitoring. Biosens Bioelectron 2019; 137:25-32. [PMID: 31077987 DOI: 10.1016/j.bios.2019.05.002] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Accepted: 05/01/2019] [Indexed: 01/29/2023]
Abstract
Continuous glucose monitoring facilitates the stringent control of blood glucose concentration in diabetic and intensive care patients. Optical fibers have emerged as an attractive platform; however, their practical applications are hindered due to lack of biocompatible fiber materials, complex and non-practical readout approaches, slow response, and time-consuming fabrication processes. Here, we demonstrate the quantification of glucose by smartphone-integrated fiber optics that overcomes existing technical limitations. Simultaneously, a glucose-responsive hydrogel was imprinted with an asymmetric microlens array and was attached to a multimode silica fiber's tip during photopolymerization, and subsequent interrogated for glucose sensing under physiological conditions. A smartphone and an optical power meter were employed to record the output signals. The functionalized fiber showed a high sensitivity (2.6 μW mM-1), rapid response, and a high glucose selectivity in the physiological glucose range. In addition, the fiber attained the glucose complexation equilibrium within 15 min. The lactate interference was also examined and it was found minimal ∼0.1% in the physiological range. A biocompatible hydrogel made of polyethylene glycol diacrylate was utilized to fabricate a flexible hydrogel fiber to replace the silica fiber, and the fiber's tip was functionalized with the glucose-sensitive hydrogel during the ultraviolet light curing process. The biocompatible fiber was quickly fabricated by the molding, the readout approach was facile and practical, and the response to glucose was comparable to the functionalized silica fiber. The fabricated optical fiber sensors may have applications in wearable and implantable point-of-care and intensive-care continuous monitoring systems.
Collapse
|
11
|
Dispersion of near-infrared laser energy through radicular dentine when using plain or conical tips. Lasers Med Sci 2017; 33:251-255. [PMID: 29063474 DOI: 10.1007/s10103-017-2352-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2017] [Accepted: 10/02/2017] [Indexed: 10/18/2022]
Abstract
The aim of this study was to investigate the influence of tip design on patterns of laser energy dispersion through the dentine of tooth roots when using near-infrared diode lasers. Diode laser emissions of 810 or 940 nm were used in combination with optical fiber tips with either conventional plain ends or conical ends, to irradiate tooth roots of oval or round cross-sectional shapes. The lasers were operated in continuous wave mode at 0.5 W for 5 s with the distal end of the fiber tip placed in the apical or coronal third of the root canal at preset positions. Laser light exiting through the roots and apical foramen was imaged, and the extent of lateral spread calculated. There was a significant difference in infrared light exiting the root canal apex between plain and conical fiber tips for both laser wavelengths, with more forward transmission of laser energy through the apex for plain tips. For both laser wavelengths, there were no significant differences in emission patterns when the variable of canal shape was used and all other variables were kept the same (plain vs conical tip, tip position). To ensure optimal treatment effect and to prevent the risks of inadvertent laser effects on the adjacent periapical tissues, it is important to have a good understanding of laser transmission characteristics of the root canal and root dentine. Importantly, it is also essential to understand transmission characteristics of plain and conical fibers tips.
Collapse
|
12
|
A Clinical Wide-Field Fluorescence Endoscopic Device for Molecular Imaging Demonstrating Cathepsin Protease Activity in Colon Cancer. Mol Imaging Biol 2017; 18:820-829. [PMID: 27154508 DOI: 10.1007/s11307-016-0956-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
PURPOSE Early and effective detection of cancers of the gastrointestinal tract will require novel molecular probes and advances in instrumentation that can reveal functional changes in dysplastic and malignant tissues. Here, we describe adaptation of a wide-field clinical fiberscope to perform wide-field fluorescence imaging while preserving its white-light capability for the purpose of providing wide-field fluorescence imaging capability to point-of-care microscopes. PROCEDURES We developed and used a fluorescent fiberscope to detect signals from a quenched probe, BMV109, that becomes fluorescent when cleaved by, and covalently bound to, active cathepsin proteases. Cathepsins are expressed in inflammation- and tumor-associated macrophages as well as directly from tumor cells and are a promising target for cancer imaging. The fiberscope has a 1-mm outer diameter enabling validation via endoscopic exams in mice, and therefore we evaluated topically applied BMV109 for the ability to detect colon polyps in an azoxymethane-induced colon tumor model in mice. RESULTS This wide-field endoscopic imaging device revealed consistent and clear fluorescence signals from BMV109 that specifically localized to the polypoid regions as opposed to the normal adjacent colon tissue (p < 0.004) in the murine colon carcinoma model. CONCLUSIONS The sensitivity of detection of BMV109 with the fluorescence fiberscope suggested utility of these tools for early detection at hard-to-reach sites. The fiberscope was designed to be used in conjunction with miniature, endoscope-compatible fluorescence microscopes for dual wide-field and microscopic cancer detection.
Collapse
|
13
|
Wide bandwidth fiber-optic ultrasound probe in MOMS technology: Preliminary signal processing results. ULTRASONICS 2017; 75:164-173. [PMID: 27992840 DOI: 10.1016/j.ultras.2016.11.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2016] [Revised: 09/29/2016] [Accepted: 11/29/2016] [Indexed: 06/06/2023]
Abstract
An ultrasonic probe consisting of two optical fiber-based miniaturized transducers for wideband ultrasound emission and detection is employed for the characterization of in vitro biological tissues. In the probe, ultrasound generation is obtained by thermoelastic emission from patterned carbon films in Micro-Opto-Mechanical-System (MOMS) devices mounted on the tip of an optical fiber, whereas acousto-optical detection is performed in a similar way by a miniaturized polymeric interferometer. The microprobe presents a wide, flat bandwidth that is a very attractive feature for ultrasonic investigation, especially for tissue characterization. Thanks to the very high ultrasonic frequencies obtained, the probe is able to reveal different details of the object under investigation by analyzing the ultrasonic signal within different frequencies ranges, as shown by specific experiments performed on a patterned cornstarch flour sample in vitro. This is confirmed by measurements executed to determine the lateral resolution of the microprobe at different frequencies of about 70μm at 120MHz. Moreover, measurements performed with the wideband probe in pulsed-echo mode on a histological finding of porcine kidney are presented, on which two different spectral signal processing algorithms are applied. After processing, the ultrasonic spectral features show a peculiar spatial distribution on the sample, which is expected to depend on different ultrasonic backscattering properties of the analyzed tissues.
Collapse
|
14
|
Optical fiber meta-tips. LIGHT, SCIENCE & APPLICATIONS 2017; 6:e16226. [PMID: 30167235 PMCID: PMC6062173 DOI: 10.1038/lsa.2016.226] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Revised: 08/30/2016] [Accepted: 09/06/2016] [Indexed: 05/09/2023]
Abstract
We report on the first demonstration of a proof-of-principle optical fiber 'meta-tip', which integrates a phase-gradient plasmonic metasurface on the fiber tip. For illustration and validation purposes, we present numerical and experimental results pertaining to various prototypes implementing generalized forms of the Snell's transmission/reflection laws at near-infrared wavelengths. In particular, we demonstrate several examples of beam steering and coupling with surface waves, in fairly good agreement with theory. Our results constitute a first step toward the integration of unprecedented (metasurface-enabled) light-manipulation capabilities in optical-fiber technology. By further enriching the emergent 'lab-on-fiber' framework, this may pave the way for the widespread diffusion of optical metasurfaces in real-world applications to communications, signal processing, imaging and sensing.
Collapse
|
15
|
Localized Surface Plasmon Resonance (LSPR)-Coupled Fiber-Optic Nanoprobe for the Detection of Protein Biomarkers. Methods Mol Biol 2017; 1571:1-14. [PMID: 28281246 DOI: 10.1007/978-1-4939-6848-0_1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Here is presented a miniaturized, fiber-optic (FO) nanoprobe biosensor based on the localized surface plasmon resonance (LSPR) at the reusable dielectric-metallic hybrid interface with a robust, gold nano-disk array at the fiber end facet. The nanodisk array is directly fabricated using electron beam lithography (EBL) and metal lift-off process. The free prostate-specific antigen (f-PSA) has been detected with a mouse anti-human prostate-specific antigen (PSA) monoclonal antibody (mAb) as a specific receptor linked with a self-assembled monolayer (SAM) at the LSPR-FO facet surfaces. Experimental investigation and data analysis found near field refractive index (RI) sensitivity at ~226 nm/RIU with the LSPR-FO nanoprobe, and demonstrated the lowest limit of detection (LOD) at 100 fg/mL (~3 fM) of f-PSA in PBS solutions. The SAM shows insignificant nonspecific binding to the target biomarkers in the solution. The control experimentation using 5 mg/mL bovine serum albumin in PBS and nonspecific surface test shows the excellent specificity and selectivity in the detection of f-PSA in PBS. These results indicate important progress toward a miniaturized, multifunctional fiber-optic technology that integrates informational communication and sensing function for developing a high-performance, label-free, point-of-care (POC) device.
Collapse
|
16
|
Competitive inhibition assay for the detection of progesterone in dairy milk using a fiber optic SPR biosensor. Anal Chim Acta 2016; 950:1-6. [PMID: 27916114 DOI: 10.1016/j.aca.2016.11.005] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Revised: 10/28/2016] [Accepted: 11/05/2016] [Indexed: 01/12/2023]
Abstract
Analytical methods that are often used for the quantification of progesterone in bovine milk include immunoassays and chromatographic techniques. Depending on the selected method, the main disadvantages are the cost, time-to-result, labor intensity and usability as an automated at-line device. This paper reports for the first time on a robust and practical method to quantify small molecules, such as progesterone, in complex biological samples using an automated fiber optic surface plasmon resonance (FO-SPR) biosensor. A FO-SPR competitive inhibition assay was developed to determine biologically relevant concentrations of progesterone in bovine milk (1-10 ng/mL), after optimizing the immobilization of progesterone-bovine serum albumin (P4-BSA) conjugate, the specific detection with anti-progesterone antibody and the signal amplification with goat anti-mouse gold nanoparticles (GAM-Au NPs). The progesterone was detected in a bovine milk sample with minimal sample preparation, namely ½ dilution of the sample. Furthermore, the developed bioassay was benchmarked against a commercially available ELISA, showing excellent agreement (R2 = 0.95). Therefore, it is concluded that the automated FO-SPR platform can combine the advantages of the different existing methods for quantification of progesterone: sensitivity, accuracy, cost, time-to-result and ease-of-use.
Collapse
|
17
|
Fiber optic-SPR platform for fast and sensitive infliximab detection in serum of inflammatory bowel disease patients. Biosens Bioelectron 2015; 79:173-9. [PMID: 26706938 DOI: 10.1016/j.bios.2015.11.087] [Citation(s) in RCA: 67] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Revised: 11/24/2015] [Accepted: 11/27/2015] [Indexed: 12/16/2022]
Abstract
Infliximab (IFX) is a therapeutic monoclonal antibody used for treating patients with inflammatory bowel disease (IBD). In order to improve therapeutic outcomes it is recommended to monitor IFX trough concentrations. Although ELISA is currently widely used for this purpose, this method is not suitable for single patient testing. In this paper we describe the development of a fast bioassay for determining IFX concentration in serum using an in-house developed fiber-optic surface plasmon resonance (FO-SPR) biosensor. Studies were first conducted to optimize covalent immobilization of the IFX-specific antibody on the sensor surface as well as to select an optimal blocking buffer for restraining the non-specific binding. In order to reach clinically relevant sensitivity for detecting IFX in patients' serum, the SPR signal was amplified by employing gold nanoparticles functionalized with another set of IFX specific antibodies. Using the optimized sandwich bioassay, calibration curves were made with series of IFX concentrations spiked in buffer and 100-fold diluted serum, reaching the limit of detection of 0.3 and 2.2ng/ml, respectively. The established bioassay was finally validated using five IFX treated IBD patients samples. Results from the FO-SPR platform were compared with an in-house developed, clinically validated ELISA resulting in excellent Pearson and intraclass correlation coefficient of 0.998 and 0.983, respectively. Furthermore, the assay time of the FO-SPR platform was significantly reduced compared to ELISA, demonstrating the potential of this platform to be used as a point-of-care diagnostic tool for improving therapeutic outcomes of IBD patients.
Collapse
|
18
|
An enhanced LSPR fiber-optic nanoprobe for ultrasensitive detection of protein biomarkers. Biosens Bioelectron 2014; 61:95-101. [PMID: 24858997 DOI: 10.1016/j.bios.2014.05.009] [Citation(s) in RCA: 83] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2014] [Revised: 04/15/2014] [Accepted: 05/03/2014] [Indexed: 01/01/2023]
Abstract
A miniaturized, localized surface plasmon resonance (LSPR)-coupled fiber-optic (FO) nanoprobe is reported as a biosensor that is capable of label-free, sensitive detection of a cancer protein biomarker, free prostate specific antigen (f-PSA). The biosensor is based on the LSPR at the reusable dielectric-metallic hybrid interface with a robust, gold nano-disk array at the fiber end facet that is directly fabricated using EBL and metal lift-off process. The f-PSA has been detected with a mouse anti-human PSA monoclonal antibody (mAb) as a specific receptor linked with a self-assembled monolayer at the LSPR-FO facet surfaces. Experimental investigation and data analysis found near field refractive index (RI) sensitivity at ~226 nm/RIU with current LSPR-FO nanoprobe, and demonstrated the lowest limit of detection (LOD) at 100 fg/mL (~3 fM) of f-PSA in PBS solutions. The control experimentation using 5mg/mL bovine serum albumin in PBS and nonspecific surface test shows the excellent specificity and selectivity in the detection of f-PSA in PBS. These results present important progress towards a miniaturized, multifunctional fiber-optic technology that integrates informational communication and sensing function for developing a high performance, label-free, point-of-care (POC) device.
Collapse
|
19
|
SU-E-J-196: In-Vivo Tumor Blood-Oxygen Content Measurement via Interstitial Optical Transmission Spectroscopy. Med Phys 2012; 39:3698. [PMID: 28519036 DOI: 10.1118/1.4735037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To demonstrate the application of in-vivo diffuse optical transmission spectroscopy in quantifying oxygen saturation in interstitial tissue, and to use this technique to examine reoxygenation dynamics in real-time as tumors responds to radiotherapy. METHODS Two 200 micron core fiber optics were threaded through two 21 gauge hypodermic needles: one coupled to an OceanOptics QE65000 spectrometer, and the other to an Ocean Optics HL-2000-HP 20W light source. These needles were fixed approximately 3 mm apart, and inserted into nude mice with human head- and-neck tumor xenografts. The oxygen saturation was then measured as a function of time after irradiation at intervals of 0.5, 1, 2, 6, 12, and 24, to measure the tumors' prompt oxygen saturation response to radiation. RESULTS Blood volume, deoxy and oxy-hemoglobin concentrations were measured through least-squares fitting of transmission spectra. Furthermore, various configurations of interstitial fiber optic probes were explored to optimize signal strength. Improvement of the optical coupling to the biological system and a concurrent increase in source intensity are the main two focuses for boosting signal strength. CONCLUSIONS This work has the potential to give an understanding of the time-scales of hypoxia and reoxygenation in vivo as tumors respond to radiation injury. This technique is of particular interest for hypofractionated therapies particularly treatments of only two or three treatments, where optimizing treatment timing can increase the tumorcidal effect of the remaining fractions.
Collapse
|