1
|
Comparation of the outcomes between ProGlide based post-closure technique and arteriotomy repair for veno-arterial extracorporeal membrane oxygenation decannulation. J Crit Care 2024; 79:154434. [PMID: 37742517 DOI: 10.1016/j.jcrc.2023.154434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 07/11/2023] [Accepted: 09/16/2023] [Indexed: 09/26/2023]
Abstract
PURPOSE To compare outcomes between post-closure technique based on ProGlide and arteriotomy repair for veno-arterial extracorporeal membrane oxygenation (VA-ECMO) decannulation in this study. MATERIALS AND METHODS Patients who received VA-ECMO treatment and successfully removed from its support in Changhai Hospital from January 2018 to December 2021 were included in this study. Patients was divided into post-closure group and surgical repair group according to the artery access closure method used. Clinical data of these patients were retrospectively collected and analyzed. RESULTS A total of 58 patients were eventually enrolled in this study, including 26 (44.83%) patients in post-closure group and 32 (55.17%) patients in surgical repair group. Post-closure group had shorter procedure time, less minor bleeding events, estimated blood loss and packed cells transfused compared with the surgical repair group. The intensive care unit (ICU) length of stay after decannulation and the hospital length of stay after ICU in post-closure group were both shorter than surgical repair group. Nine patients (15.52%) died of multiple system organ failure after decannulation in this cohort and there were no significant differences between two groups. CONCLUSIONS Our study showed the post-closure technique based on ProGlide for VA-ECMO decannulation is feasible, safe and effective.
Collapse
|
2
|
Outcomes with plug-based versus suture-based vascular closure device after transfemoral transcatheter aortic valve replacement: A systematic review and meta-analysis. Catheter Cardiovasc Interv 2023; 101:817-827. [PMID: 36802100 DOI: 10.1002/ccd.30597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 10/25/2022] [Accepted: 02/04/2023] [Indexed: 02/21/2023]
Abstract
BACKGROUND Studies comparing plug-based (i.e., MANTA) with suture-based (i.e., ProStar XL and ProGlide) vascular closure devices (VCDs) for large-bore access closure after transcatheter aortic valve replacement (TAVR) have yielded mixed results. AIMS To examine the comparative safety and efficacy of both types of VCDs among TAVR recipients. METHODS An electronic database search was performed through March 2022 for studies comparing access-site related vascular complications with plug-based versus suture-based VCDs for large-bore access site closure after transfemoral (TF) TAVR. RESULTS Ten studies (2 randomized controlled trials [RCTs] and 8 observational studies) with 3113 patients (MANTA = 1358, ProGlide/ProStar XL = 1755) were included. There was no difference between plug-based and suture-based VCD in the incidence of access-site major vascular complications (3.1% vs. 3.3%, odds ratio [OR]: 0.89; 95% confidence interval [CI]: 0.52-1.53). The incidence of VCD failure was lower in plug-based VCD (5.2% vs. 7.1%, OR: 0.64; 95% CI: 0.44-0.91). There was a trend toward a higher incidence of unplanned vascular intervention in plug-based VCD (8.2% vs. 5.9%, OR: 1.35; 95% CI: 0.97-1.89). Length of stay was shorter with MANTA. Subgroup analyses suggested significant interaction based on study designs such that there was higher incidence of access-site vascular complications and bleeding events with plug-based versus suture-based VCD among RCTs. CONCLUSION In patients undergoing TF-TAVR, large-bore access site closure with plug-based VCD was associated with a similar safety profile as suture-based VCD. However, subgroup analysis showed that plug-based VCD was associated with higher incidence of vascular and bleeding complications in RCTs.
Collapse
|
3
|
Comparison of plug-based versus suture-based vascular closure for large-bore arterial access: a collaborative meta-analysis of observational and randomized studies. Clin Res Cardiol 2023; 112:614-625. [PMID: 36749418 PMCID: PMC10160216 DOI: 10.1007/s00392-022-02145-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Accepted: 12/19/2022] [Indexed: 02/08/2023]
Abstract
BACKGROUND Large-bore arteriotomies can be percutaneously closed with suture-based or plug-based vascular closure device (VCD) strategies. The efficacy of both techniques remains controversial. AIMS We conducted a meta-analysis of comparative studies between both VCD strategies, focusing on the most commonly applied VCDs (MANTA and ProGlide). METHODS We searched MEDLINE, the Cochrane Central Register of Controlled Trials and Google scholar for observational studies (OS) and randomized controlled trials (RCT) comparing vascular closure with the MANTA-based and the ProGlide-based technique. The principal endpoint of this analysis was access-site related vascular complications. Both study types were analyzed separately. RESULTS Access-site related vascular complications were less frequent after vascular closure with the MANTA technique in the analysis of OS (RR 0.61 [95%CI 0.43-0.89], p = 0.01, I2 = 0%), but more frequent in the analysis of RCT data (RR 1.70 [95%CI 1.16-2.51], p = 0.01, I2 = 0%). Both data sets provided no significant difference between the VCD techniques in terms of overall bleeding events (OS: RR 0.57 [95%CI 0.32-1.02], p = 0.06, I2 = 70%; and RCT: RR 1.37 [95%CI 0.82-2.28], p = 0.23, I2 = 30%). RCT data showed that endovascular stenting or vascular surgery due to VCD failure occurred more often after MANTA application (RR 3.53 [95%CI 1.07-11.33], p = 0.04, I2 = 0%). CONCLUSIONS While OS point to favorable outcomes for large-bore vascular closure with the MANTA-based technique, RCT data show that this strategy is associated with more access-site related vascular complications as well as endovascular stenting or vascular surgery due to device failure compared with the ProGlide-based technique.
Collapse
|
4
|
Suture-based vs. pure plug-based vascular closure devices for VA-ECMO decannulation-A retrospective observational study. Front Cardiovasc Med 2023; 10:1106114. [PMID: 36776253 PMCID: PMC9908581 DOI: 10.3389/fcvm.2023.1106114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Accepted: 01/10/2023] [Indexed: 01/27/2023] Open
Abstract
Background Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a valuable treatment option for patients in cardiogenic shock, but complications during decannulation may worsen the overall outcome. Therefore, the aim of this study was to compare the efficacy and safety of suture-based to pure plug-based vascular closure devices for VA-ECMO decannulation. Methods In this retrospective study, the procedural outcome of 33 patients with suture-based Perclose ProGlide closure devices was compared to 38 patients with MANTA plug-based closure devices. Results Rate of technically correct placement of closure devices was 88% in the suture-based group and 97% in the plug-based group (p = 0.27). There was a significant reduction of severe bleeding events during VA-ECMO decannulation in plug-based versus suture-based systems (3% vs. 21%, p = 0.04). Ischemic complications occurred in 6% with suture-based and 5% with plug-based device (p = 1.00). Pseudoaneurysm formation was detected in 3% in both groups (p = 1.00). No switch to vascular surgery due to bleeding after decannulation was necessary in both groups. Conclusion Based on our retrospective analysis, we propose that plug-based vascular closure should be the preferred option for VA-ECMO decannulation. This hypothesis should be further tested in a randomized trial.
Collapse
|
5
|
Acute limb ischemia after minimally invasive cardiac surgery using the ProGlide: A case series. World J Clin Cases 2022; 10:13052-13057. [PMID: 36569024 PMCID: PMC9782955 DOI: 10.12998/wjcc.v10.i35.13052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 10/12/2022] [Accepted: 11/17/2022] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND We report two cases of acute femoral artery occlusion following the use of ProGlide in minimally invasive cardiac surgery and insertion of large-bore catheters through the common femoral artery. This will add to the existing body of literature by highlighting the possible complications associated with the use of ProGlide and reiterate that the use of the sono-guided ProGlide skill will reduce the incidence of these complications.
CASE SUMMARY A 78-year-old man underwent minimally invasive cardiac surgery for severe aortic valve stenosis. After the operation, the puncture site of the common femoral artery was closed using ProGlide. The next morning, after regaining consciousness, he complained of pain, motor weakness (grade 2), and coldness in the right lower extremity. A 65-year-old man underwent minimally invasive cardiac surgery for a large secundum atrial septal defect (5 cm × 5 cm). After the operation, the puncture site of the common femoral artery was closed using ProGlide. After extubation, the patient complained of paresthesia of the right thigh. Both the patients underwent emergency surgery for acute occlusion of the common femoral artery.
CONCLUSION If the sono-guided ProGlide skill is used, complications can be prevented, and ProGlide can be safely used.
Collapse
|
6
|
Percutaneous Approach in Endovascular Aortic Procedures Using a Suture-Mediated Closure Device. J Clin Med 2022; 11:jcm11226660. [PMID: 36431136 PMCID: PMC9695263 DOI: 10.3390/jcm11226660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 11/05/2022] [Accepted: 11/07/2022] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND The purpose of this study is to assess the efficacy of a suture-mediated closure device during percutaneous endovascular aortic repair. METHODS A single-center, retrospective analysis of patients undergoing endovascular repair for infrarenal, thoracic and thoracoabdominal aortic aneurysms and aortic dissections via percutaneous femoral access between April 2017 and June 2021 was performed. The primary endpoint of the study was the efficacy and technical success of the Perclose ProGlide closure device during percutaneous endovascular procedures. The secondary endpoints were intraoperative and postoperative inguinal and vascular complications during and after device use. RESULTS A total of 376 punctures were performed in 263 patients with the deployment of the ProGlide vascular closure system. Twenty-two cases involved percutaneous re-puncture as part of a staged procedure. The primary and secondary technical success rates were 93.1% (350/376) and 94.7% (356/376), respectively. In 20 patients (5.3%), intraoperative femoral exposure due to complications was required. Postoperative complications occurred in 13 cases (3.5%), 2 of which required surgical reintervention. There was no statistical significance between the type of endovascular procedure and primary technical success (p = 0.56). The introduction of larger-diameter sheaths was not associated with increased intraoperative and postoperative complication rates (p = 0.75 and p = 0.78, respectively). Percutaneous re-puncture of the vascular access site did not result in a lower overall technical success rate (20/22, 90.9% primary technical success rate, p = 0.67; 21/22, 95.5% secondary technical success rate, p = 0.86) or an increased number of perioperative complications (1/22, 4.5% intraoperative complications, p = 0.86; 2/22, 9.1% postoperative complications, p = 0.13). CONCLUSION The application of the ProGlide closure system is a safe and efficient method to achieve hemostasis during percutaneous endovascular aortic repair. Complex aortic pathologies, which often require a staged approach with re-puncture, can also be successfully treated with this closure system.
Collapse
|
7
|
Large-bore arterial access closure after transcatheter aortic valve replacement: a systematic review and network meta-analysis. EUROPEAN HEART JOURNAL OPEN 2022; 2:oeac043. [PMID: 36117948 PMCID: PMC9472788 DOI: 10.1093/ehjopen/oeac043] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Revised: 06/27/2022] [Indexed: 02/03/2023]
Abstract
Aims As the indications to transcatheter aortic valve replacement (TAVR) expand to patients at increasingly lower risk, procedure-related vascular and bleeding complications events must be minimized. We aimed to evaluate the impact of different large-bore arterial access closure devices on clinical outcomes after TAVR. Methods and results We searched for papers that reported outcomes according to the type of vascular closure device/technique used after TAVR and performed a Bayesian network meta-analysis (NMA). Fifteen studies involving 9259 patients who underwent access site closure using PROSTAR™ XL percutaneous vascular surgical system (Abbott Vascular, Santa Clara, CA, USA), Perclose ProGlide™ suture-mediated closure system (Abbott), or MANTATM vascular closure device (Teleflex, Morrisville, NC, USA) were included. NMA showed MANTA to have the highest likelihood of reducing a primary composite endpoint of intra-hospital death, major vascular complications, and major or life-threatening bleedings [surface under the cumulative ranking curve analysis (SUCRA) 94.8%], but this was mitigated when only randomized clinical trials and propensity-matched cohorts were included (SUCRA 56.1%). The ProGlide showed the highest likelihood to reduce major or life-threatening bleedings, especially with increasing procedural complexity, and the MANTA device to reduce major and minor vascular complications. The ProStar XL device performed poorly in all explored endpoints. Conclusion Available evidence summarized through a NMA shows that ProGlide and MANTA devices appear to be both valid vascular closure devices globally and to be the best options to minimize vascular complications and reduce bleeding in patients undergoing TAVR, respectively.
Collapse
|
8
|
Comparing the outcomes of bedside percutaneous VA-ECMO decannulation by ProGlide and Manta in a high-ECMO-volume center in Hong Kong. Artif Organs 2022; 46:1382-1388. [PMID: 35132654 DOI: 10.1111/aor.14198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Revised: 12/22/2021] [Accepted: 01/24/2022] [Indexed: 11/29/2022]
Abstract
BACKGROUND The use of veno-arterial extracorporeal membrane oxygenation (VA-ECMO) decannulation with different percutaneous closure devices has been increasing. At our centre, ProGlide devices have been used since November 2018, and Manta devices became an alternative since March 2020. This study aimed to compare the success and complication rates and the clinical outcomes of ProGlide and Manta devices for VA-ECMO decannulation after arteriotomy wound closure. METHODS We retrospectively reviewed the results of bedside VA-ECMO decannulation between November 2018 and June 2021. Patients with VA-ECMO who could be bridged to recovery were recruited and divided into the ProGlide or Manta group based on the closure device used. Procedure time, amount of blood loss, amount of blood products transfused, and use of vasoactive medications during the procedure were documented. Clinical examination and Doppler ultrasound were performed to detect any complications. RESULTS After the closure technique, ProGlide was used in 44 patients and Manta was used in 13. There was no significant difference in the success rate between the ProGlide and Manta groups (86.4% vs. 100%). Amount of blood loss was greater in the ProGlide group than in the Manta group (290 [100-400] mL vs. 50 [50-100] mL), and more patients in the ProGlide group required an increased dose of inotropes during the procedure (59.1% vs. 15.4%), but the transfusion requirement was similar between the two groups. CONCLUSIONS The success rate of haemostasis using arteriotomy wound closure during VA-ECMO decannulation was similar between the two devices.
Collapse
|
9
|
A Randomized Trial Comparing Polymer Versus Suture-Based Vascular Closure Devices for Arterial Closure Following Lower-Limb Arterial Endovascular Revascularization. Cardiovasc Intervent Radiol 2021; 44:1883-1892. [PMID: 34386892 DOI: 10.1007/s00270-021-02940-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 07/31/2021] [Indexed: 12/19/2022]
Abstract
PURPOSES The primary objective of this study (STEP trial) was to compare the efficacy of the polymer-based FemoSeal® vascular closure device (VCD) and the suture-based ProGlide® VCD in achieving hemostasis at the femoral access site after lower-limb arterial endovascular revascularization. MATERIALS AND METHODS STEP was a multicenter randomized clinical trial including patients undergoing lower-limb arterial endovascular revascularization. The primary endpoint was technical success 5 h after the VCD intervention, defined as achievement of hemostasis without the need for a follow-up intervention at the access site and without a 2-g/dL drop in hemoglobin. RESULTS Between December 2017 and April 2019, 113 patients were assigned to the FemoSeal® group (FS) and 117 to the ProGlide® group (PG). VCD interventions were technically successful for 90 FS patients (80%) and 58 PG patients (50%) (odds ratio, 3.98; 95% CI, 2.22 to 7.14; p < 0.0001). This difference in success rates between FS and PG is partly explained by more frequent recourse to manual compression (FS: n = 19; PG: n = 45) and an additional VCD (FS: n = 0; PG: n = 23) in the latter group. After 5 h, 87% of FS patients and 69% of PG patients resumed ambulation (odds ratio: 3.07; 95% CI: 1.93 to 6.15; p = 0.0016). CONCLUSIONS In patients undergoing lower-limb arterial endovascular revascularization, FemoSeal® was superior to ProGlide® in terms of technical success. CLINICAL TRIAL REGISTRATION Step trial was registered on http://ClinicalTrials.gov (NCT03192033).
Collapse
|
10
|
A Single Center Study of ProGlide Used for Closure of Large-Bore Puncture Holes After EVAR for AAA. Vasc Endovascular Surg 2021; 55:798-803. [PMID: 34105422 DOI: 10.1177/15385744211022654] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
PURPOSE The objective of this study was to evaluate the primary and assisted secondary percutaneous and non-invasive technical success of the ProGlide device on all-comers in a consecutive case series of percutaneous endovascular aortic aneurysm repair (P-EVAR). METHOD A single-center consecutive case series where 434 elective and acute P-EVAR procedures were registered prospectively between May 2011 and July 2017. The mean age was 74.5 years ± SD 11.4 years. 82.3% of the patients were male. All patients were pre-planned from CT angiography. Percutaneous access punctures, performed in local anesthesia in the common femoral artery, with a final introducer size between 12-22 Fr OD were included and stratified in 2 groups, 12-16 Fr and 17-22 Fr. RESULTS By screening 868 access groins 22 groins were excluded. Of the remaining 846 groins, intended to be treated with ProGlide, 9 groins were excluded peri-procedurally and treated with the Fascia Suture Technique or surgical cutdown. The remaining 837 groins had access closure with ProGlide, with a mean value of 2.15 devices per groin with a slight significant difference between the 2 stratification groups. Primary ProGlide technical success was achieved in 68.1% of the groins. Secondary percutaneous or non-invasive technical success was achieved in 96.9%. Here there was no statistically significant difference between the 2 stratification groups. Thirty-one (3.7%) groin complications were registered during 30-day follow-up and 17 required additional treatment. Total mortality was 2.8%. None of these deaths were related to the access site. CONCLUSION ProGlide by itself has a significant failure rate in the closure of large-bore access holes on an unselected cohort of patients eligible for P-EVAR. However, together with adjunct percutaneous or non-invasive methods a success rate of 97% can be achieved. The access complication rate was lower than 4% at 30-day follow-up.
Collapse
|
11
|
Control of Femoral Cannulation with a ProGlide Pre-Closure Device during Cardiac Surgery: Is It Reliable? J Chest Surg 2021; 54:179-185. [PMID: 33911051 PMCID: PMC8181693 DOI: 10.5090/jcs.21.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 03/13/2021] [Accepted: 03/17/2021] [Indexed: 11/16/2022] Open
Abstract
Background The use of ProGlide as a percutaneous vascular closure device in cardiac surgery remains inconclusive. This study investigated the clinical outcomes of using Pro- Glide in the percutaneous cannulation of femoral vessels in adult cardiac surgery. Methods From September 2017 to July 2018, 131 consecutive patients underwent femoral vessel cannulation during cardiac surgery. The ProGlide (Abbott Vascular Inc., Santa Clara, CA, USA) with percutaneous cannulation was used in 118 patients (mean age, 55.7±15.5 years). The accessibility of femoral cannulation was evaluated through preoperative computed tomography. For cannulation, sonography was routinely used. The postoperative ankle-brachial index (ABI) was used to evaluate femoral artery stenosis. Results Of the 118 patients, 112 (94.9%) and 6 (5.1%) underwent minimally invasive cardiac surgery and median sternotomy, respectively. Most femoral cannulations were performed on the right side (98.3%) using 15F to 19F arterial cannulas. The technical success rate of cannulation with ProGlide was 99.2%, with no delayed bleeding or cannulation site-related complications during hospitalization. During follow-up, only 1 patient showed femoral artery stenosis with claudication and was treated with interventional balloon angioplasty. The postoperative ABI revealed no significant difference in functional stenosis between the cannulation and non-cannulation sides (n=86; cannulation vs. non-cannulation, 1.2±0.1 vs. 1.1±0). Conclusion Percutaneous femoral cannulation with ProGlide was safe and feasible in adult cardiac surgery. This technique may be a good alternative option in patients requiring femoral vessel cannulation for cardiac surgery.
Collapse
|
12
|
Single versus double use of a suture-based closure device for transfemoral aortic valve implantation. Int J Cardiol 2021; 331:183-188. [PMID: 33529662 DOI: 10.1016/j.ijcard.2021.01.043] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 01/11/2021] [Accepted: 01/22/2021] [Indexed: 12/17/2022]
Abstract
BACKGROUND The most common method of percutaneous closure in transfemoral transcatheter aortic valve implantation (TAVI) employs two obtusely oriented ProGlide devices. The aim of this study was to assess the feasibility and safety of using a single ProGlide system for primary access site closure in comparison with the double ProGlide approach in an all-comers TAVI population. METHODS Between March 2016 and December 2018, a total of 1105 patients underwent transfemoral TAVI for severe aortic stenosis at our center. Application of two ProGlide systems was standard until April 2017 (n = 432), whereas thereafter a single ProGlide system was used (n = 663). A 1:1 propensity score matching was performed to adjust for baseline differences between the two groups, resulting in 327 matched cases. Primary outcomes of interest were main access site-related vascular complications. RESULTS The mean number of ProGlide devices used per patient was 1.03 (SD 0.2) in the single-ProGlide group versus 2.01 (SD 0.14) in the double-ProGlide group. An additional vascular closure device was required to obtain full hemostasis in 23.2% versus 9.5% of patients (p < 0.001) in the two groups, respectively. Technical success of ProGlide usage was similar (94.3% versus 92.1%, p = 0.163). In the matched cohorts, the rates of main access site-related major vascular complications were similar (4.0% vs. 6.4%, p = 0.217). CONCLUSION The single-ProGlide technique is feasible, with rates of technical success similar to those of the double-ProGlide technique. Use of this method did not lead to more frequent access site-related complications but was more cost effective than the double-ProGlide approach.
Collapse
|
13
|
Suture- or Plug-Based Large-Bore Arteriotomy Closure: A Pilot Randomized Controlled Trial. JACC Cardiovasc Interv 2020; 14:149-157. [PMID: 33358648 DOI: 10.1016/j.jcin.2020.09.052] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 09/23/2020] [Accepted: 09/29/2020] [Indexed: 12/17/2022]
Abstract
OBJECTIVES This study sought to test the superiority in terms of efficacy and safety of a dedicated plug-based vascular closure device (VCD) during transcatheter aortic valve replacement (TAVR) over a suture-based VCD. BACKGROUND Vascular complications after TAVR are relevant and often associated with VCD failure. METHODS The MASH (MANTA vs. Suture-based vascular closure after transcatHeter aortic valve replacement) trial is an international, 2-center pilot randomized controlled trial comparing the MANTA VCD (Teleflex, Wayne, Pennsylvania) versus 2 ProGlides (Abbott Vascular, Abbott Park, Illinois). The primary composite endpoint consisted of access site-related major or minor vascular complications at 30-days' follow-up. Secondary endpoints included clinically relevant access site bleeding, time to hemostasis, and modified VCD failure (defined as failure to achieve hemostasis within 5 min or requiring additional endovascular maneuvers such as endovascular stenting, surgical techniques, or additional closure devices). Adverse events were adjudicated by an independent clinical events committee according to the VARC-2 definitions. RESULTS A total of 210 TAVR patients were included between October 2018 and January 2020. Median age was 81 years, 54% were male, and the median STS score was 2.7%. There was no significant difference in the primary endpoint of access site-related vascular complications between MANTA and ProGlide (10% vs. 4%; p = 0.16). Clinically significant access site bleedings were similar with both closure techniques (9% vs. 6%; p = 0.57). Modified VCD failure occurred less frequently in MANTA versus ProGlide (20% vs. 40%; p < 0.01). Suture-based closure required more often additional closure devices, whereas MANTA numerically needed more covered stents and surgical bailouts. CONCLUSIONS Plug-based large-bore arteriotomy closure was not superior to suture-based closure. Plug-based closure required fewer, but a different kind of bailout maneuvers.
Collapse
|
14
|
One-year experience of bedside percutaneous VA-ECMO decannulation in a high-ECMO-volume center in Hong Kong. Perfusion 2020; 36:803-807. [PMID: 33200650 DOI: 10.1177/0267659120971998] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND When veno-arterial extracorporeal membrane oxygenation (VA-ECMO) support can be terminated, open repair of arteriotomy wounds in operating theaters is the standard of practice. Comparable outcomes by percutaneous decannulation using different closure devices have been reported. However, transport of the critically- ill, man-power and timeslots of operating theaters could be saved if decannulation was performed at bedside. METHOD Bedside percutaneous arteriotomy wound closure became our default method of decannulation since November 2018. We reviewed our 1-year data to evaluate if such practice could be safely adopted in a local high-ECMO-volume center. RESULTS Between November 2018 and October 2019, 25 patients had their VA-ECMO terminated at the bedside. Twenty-one patients (84%) had successful decannulation. For those who failed, emergency open repair resulted in no additional complications. Two ProGlide devices were used in 15 (71.4%) patients and three were used in 6 (28.6%) patients. The procedure time was 27 (15-45) min. The median blood loss was 300 mL (250-400). Minor complications were found in 4 (19.1%) patients, including two arterial clot formation, one pseudoaneurysm and one wound infection. There were no other major complications. CONCLUSION Our 1-year experience showed that percutaneous bedside VA-ECMO decannulation was feasible to commence in a local large-ECMO-volume center.
Collapse
|
15
|
Efficacy and Safety of ProGlide Versus Prostar XL Vascular Closure Devices in Transcatheter Aortic Valve Replacement: The RISPEVA Registry. J Am Heart Assoc 2020; 9:e018042. [PMID: 33103545 PMCID: PMC7763424 DOI: 10.1161/jaha.120.018042] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Background Transcatheter aortic valve replacement (TAVR) requires large‐bore access, which is associated with bleeding and vascular complications. ProGlide and Prostar XL are vascular closure devices widely used in clinical practice, but their comparative efficacy and safety in TAVR is a subject of debate, owing to conflicting results among published studies. We aimed to compare outcomes with Proglide versus Prostar XL vascular closure devices after TAVR. Methods and Results This large‐scale analysis was conducted using RISPEVA, a multicenter national prospective database of patients undergoing transfemoral TAVR treated with ProGlide versus Prostar XL vascular closure devices. Both multivariate and propensity score adjustments were performed. A total of 2583 patients were selected. Among them, 1361 received ProGlide and 1222 Prostar XL. The predefined primary end point was a composite of cardiovascular mortality, bleeding, and vascular complications assessed at 30 days and 1‐year follow‐up. At 30 days, there was a significantly greater reduction of the primary end point with ProGlide versus Prostar XL (13.8% versus 20.5%, respectively; multivariate adjusted odds ratio, 0.80 [95% CI, 0.65–0.99]; P=0.043), driven by a reduction of bleeding complications (9.1% versus 11.7%, respectively; multivariate adjusted odds ratio, 0.76 [95% CI, 0.58–0.98]; P=0.046). Propensity score analysis confirmed the significant reduction of major adverse cardiovascular events and bleeding risk with ProGlide. No significant differences in the primary end point were found between the 2 vascular closure devices at 1 year of follow‐up (multivariate adjusted hazard ratio, 0.88 [95% CI, 0.72–1.10]; P=0.902). Comparable results were obtained by propensity score analysis. During the procedure, compared with Prostar XL, ProGlide yielded significant higher device success (99.2% versus 97.5%, respectively; P=0.001). Conclusions ProGlide has superior efficacy as compared with Prostar XL in TAVR procedures and is associated with a greater reduction of composite adverse events at short‐term, driven by lower bleeding complications. Registration Information URL: clinicaltrials.gov; Unique identifier: NCT02713932.
Collapse
|
16
|
Outcomes of routine use of percutaneous access with large-bore introducer sheaths (>21F outer diameter) during endovascular aneurysm repair. J Vasc Surg 2020; 73:81-91. [PMID: 32442603 DOI: 10.1016/j.jvs.2020.04.504] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Accepted: 04/11/2020] [Indexed: 02/08/2023]
Abstract
OBJECTIVE The objective of this study was to evaluate the performance of percutaneous femoral access with large-bore sheaths (>21F outer diameter) mainly employed for thoracic and thoracoabdominal aortic endovascular treatment and to stratify the outcomes on the basis of the introducer size. METHODS Between December 2015 and December 2018, all consecutive patients who received endovascular repair through a percutaneous approach with a suture-mediated vascular closure device (VCD) and the preclose technique were included in a retrospective single-center study called Totally Percutaneous Approach to Endovascular Treatment of Aortic Aneurysms (PEVAR-PRO). The morphologic characteristics of the access vessels and patients' demographics were recorded, and 30-day closure success was defined as the primary end point. Analysis of the closure success comparing large-bore sheaths vs small-bore sheaths (≤21F outer diameter) was performed after 1:1 propensity score matching of preoperative confounding variables. RESULTS The closure success rate of the entire study cohort was 94% (622 femoral accesses in 360 patients; median age, 74 years; 84% male). Univariate analysis identified eight different factors associated with failure, but only two remained significant on multivariate analysis: diabetes (odds ratio [OR], 2.8; 95% confidence interval [CI], 1.3-6.2; P = .011) and common femoral artery stenosis >50% (OR, 4.5; 95% CI, 1.3-13.7; P = .019). After propensity score matching (1:1, 172 femoral accesses per group), closure success rate was not significantly different between large-bore and small-bore sheaths (90.7% vs 93.0%; P = .43). Multivariate analysis of the large-sheath group identified two factors associated with failure: small (<9 mm) femoral arteries (OR, 6.9; 95% CI, 1.5-31.6; P = .13) and access vessel calcifications involving more than one-third of the circumference (OR, 7.9; 95% CI, 2.1-29.4; P = .002). Neither previous femoral cutdown (44 accesses [23%]) nor percutaneous closure with VCDs (38 accesses [20%]) affected the closure success rate in the large-sheath group. Closure failure did not significantly increase the need for postoperative blood transfusions or hospital length of stay. CONCLUSIONS Off-label use of VCDs and the preclose technique for percutaneous approach with large-bore sheaths needed for complex aortic endovascular procedures is safe and feasible. Closure success rate is not significantly different from that obtained with on-label application of VCDs with smaller sheaths.
Collapse
|
17
|
Safety and effectiveness of single ProGlide vascular access in patients undergoing endovascular aneurysm repair. J Vasc Surg 2020; 72:1946-1951. [PMID: 32276013 DOI: 10.1016/j.jvs.2020.03.028] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Accepted: 03/04/2020] [Indexed: 12/17/2022]
Abstract
OBJECTIVE The objective of this study was to evaluate the safety and effectiveness of single ProGlide use per bilateral access site for endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms. METHODS A retrospective cohort study was performed for all elective percutaneous EVARs from November 2015 to December 2017 at the QEII Health Sciences Centre (Halifax, Nova Scotia, Canada). Exposure of interest was number of ProGlides used per access site, dichotomized into bilateral single ProGlide closure vs nonsingle ProGlide closure on at least one femoral arteriotomy. Outcomes included Valve Academic Research Consortium (VARC)-2 and Bleeding Academic Research Consortium (BARC) criteria. Groups were compared with Fisher exact test, analysis of variance, or Wilcoxon rank sum, as appropriate. Logistic regression was used to compare the effect of single ProGlide use on VARC-2 and BARC criteria. RESULTS A total of 131 cases were included, of which 116 had bilateral single ProGlide use for access closure. Baseline characteristics including comorbidities and smoking status were compared between groups. Groups were similar for all characteristics except smoking status, with an increased proportion of former smokers in the nonsingle ProGlide group. There were 119 (90.8%) patients who had single ProGlide use on the right femoral artery and 121 (92.4%) on the left; 16 (12.2%) patients had ProGlide deployment issues. Median maximal right and left femoral sheath diameters were 16F (interquartile range [IQR], 16F-18F) and 14F (IQR, 14F-16F), respectively. Median length of stay was 1 day (IQR, 1-1 day). VARC-2 criteria occurred in 8 of 131 (6.11%) patients, 6 of 116 (5.17%) with bilateral single ProGlides and 2 of 15 (13.3%) with nonsingle ProGlides. BARC criteria occurred in 6 of 131 (4.58%) patients, 5 of 116 (4.31%) with bilateral single ProGlides and 1 of 15 (6.67%) with nonsingle ProGlides. Single ProGlide use was not associated with a difference in VARC-2 (odds ratio, 0.35; 95% confidence interval, 0.64-1.94) or BARC (odds ratio, 0.63; 95% confidence interval, 0.07-6.79) criteria. No patients developed pseudoaneurysms or required repeated intervention for bleeding. CONCLUSIONS Single ProGlide use per vascular access site in patients undergoing EVAR is a safe and effective method for access closure with sheath diameters up to and including 16F.
Collapse
|
18
|
Percutaneous suture technique with ProGlide to manage vascular access pseudoaneurysm after percutaneous coronary intervention procedure: A case report. Chin J Traumatol 2020; 23:34-37. [PMID: 31956042 PMCID: PMC7049607 DOI: 10.1016/j.cjtee.2019.11.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2019] [Revised: 11/04/2019] [Accepted: 11/05/2019] [Indexed: 02/04/2023] Open
Abstract
Iatrogenic femoral artery pseudoaneurysm is a common complication of the endovascular procedures. Manual compression and thrombin injection are the conventional techniques to occlude the pseudoaneurysms. However, there are still some failed cases that applied these treatment options. The aim of the study is to seek a potential and alternative method with ProGlide system to close the pseudoaneurysm. During April 2018 to February 2019, 2 patients with iatrogenic pseudoaneurysm of the superficial femoral were treated with the suture-base closure device--ProGlide. After punctured the pseudoaneurysm and placed a 6-F sheath, the guide wire was placed in the right femoral artery via the access of the pseudoaneurysm neck. Then the pseudoaneurysm neck was sutured by ProGlide to occlude the blood supply to the pseudoaneurysm. These 2 patients were cured with no complications and complaints, which revealed that percutaneous suture technique with ProGlide at the neck level of pseudoaneurysm provides a novel method for the management of vascular access pseudoaneurysm, especially in those with a wide and short neck.
Collapse
|
19
|
Percutaneous Decannulation Instead of Surgical Removal for Weaning After Venoarterial Extracorporeal Membrane Oxygenation-A Crossed Perclose ProGlide Closure Device Technique Using a Hemostasis Valve Y Connector. Crit Care Explor 2019; 1:e0018. [PMID: 32166262 PMCID: PMC7063916 DOI: 10.1097/cce.0000000000000018] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Improvements in cannula removal techniques, and in particular a standardized decannulation technique with a suitable closure device, are needed to further improve patients' outcomes after percutaneous cannulation. The decannulation techniques described so far are neither sufficiently standardized nor proven enough to be used in the large group of venoarterial extracorporeal membrane oxygenation patients. To meet this challenge, we have established a highly standardized and safe decannulation technique based on the Perclose ProGlide closure system (Abbott Vascular, Lake Bluff, IL). Design Establishment of a highly standardized and safe decannulation technique based on the Perclose ProGlide closure system, which is described in detail with comprehensive instructions for the executive clinician and first application in the context of a pilot study. Measurements and Main Results So far our technique has already been used successfully in seven patients since January 2019 as a standard procedure on our ICU with only one minor complication occurred after the first procedure, that is, a small pseudoaneurysm likely originating from antegrade perfusion puncture site which was sealed by thrombin injection. Conclusions Our crossed ProGlide technique using a hemostasis valve Y connector ensuring no blood loss seems to be a very promising decannulation technique.
Collapse
|
20
|
Access site complications after transfemoral aortic valve implantation - a comparison of Manta and ProGlide. CVIR Endovasc 2018; 1:20. [PMID: 30652151 PMCID: PMC6319663 DOI: 10.1186/s42155-018-0026-0] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Accepted: 08/28/2018] [Indexed: 12/18/2022] Open
Abstract
Background Despite decreasing sheath diameter, access site bleeding and vascular complications are still a major concern in transfemoral aortic valve implantation (TAVI), and may increase morbidity and even increase mortality. The aim was to compare safety of arterial closure in transfemoral TAVI with two different principles, pre-suture with ProGlide and collagen plug closure with Manta. Results Seventy-six patients treated with ProGlide and 75 with Manta were analysed. The endpoints were 1: access site vascular complications and 2: non-planned vascular or endovascular surgery at the puncture site. Complications occurred in 2 (2.7%) ProGlide and in 8 (10.7%) Manta cases, p = 0.047. During the learning phase there were no significant differences. In the established phase there was one event (2%) in the ProGlide group, compared to 6 endpoints (12.0%), p = 0.047, in the Manta group. Unplanned surgery or intervention was seen in two (2.7%) ProGlide and in 7 (9.3%) Manta patients, p = ns. There were no significant differences during the learning phase. In established use, endpoints occurred more frequently in patients treated with the Manta device (12%), than in patients treated with the ProGlide (2%), p = 0.047. Conclusion The ProGlide presuture closure device was associated with significantly lower rates of vascular complications and lower rates of surgery and interventions compared to the collagen plug Manta system. Trial registration The data were collected from Internal quality control registry on treatment of patients with valvular heart disease with or without coronary artery disease, No 2014/17280, Oslo University Hospital, Ullevål.
Collapse
|
21
|
Femoral arterial closure using ProGlide® is more efficacious and cost-effective when ambulating early following cardiac catheterization. IJC HEART & VASCULATURE 2016; 13:6-13. [PMID: 28616553 PMCID: PMC5454184 DOI: 10.1016/j.ijcha.2016.09.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2016] [Revised: 09/08/2016] [Accepted: 09/24/2016] [Indexed: 11/30/2022]
Abstract
OBJECTIVE This was a prospective, single-center study evaluating the efficacy and cost-effectiveness of early ambulation (within 30 min) following femoral artery closure with the ProGlide® suture-mediated vascular closure device (PD) in patients undergoing diagnostic cardiac catheterization compared with manual compression. BACKGROUND It is unclear whether early ambulation with ProGlide is safe or is associated with patient satisfaction and cost savings as compared with manual compression (MC). METHODS AND RESULTS Inclusion criteria were met in 170 patients (85 PD and 85 MC patients). Patients ambulated 20 ft. within 30 min (PD) or after the requisite 4 h recumbent time (MC) if feasible. Primary endpoint was time-to-ambulation (TTA) following device closure. We also directly compared the safety of closure, times-to-hemostasis (TTH), -ambulation (TTA) and -discharge (TTD) with MC and, using a fully allocated cost model, performed cost analysis for both strategies. Multivariate analysis was used to determine predictors of patient satisfaction. The primary endpoint of safe, early ambulation was achieved following closure (mean of 27.1 ± 14.9 min; 95% confidence interval [CI] 25.2-30.2). Predictors of patient satisfaction in the PD group were absence of pain during closure, decreased TTA, and drastic reductions in TTD; the latter contributed indirectly to significant cost savings in the PD group (1250.3 ± 146.4 vs. 2248.1 ± 910.2 dollars, respectively; P < 0.001) and incremental cost savings by strategy also favored closure over MC ($84,807). CONCLUSIONS ProGlide is safe and effective for femoral artery closure in patients who ambulate within 30 min after cardiac catheterization; translating into improved patient satisfaction and substantial cost savings.
Collapse
|
22
|
Abstract
Totally percutaneous endovascular abdominal aortic aneurysm repair (PEVAR) using suture-mediated closure devices (SMCDs) has several well-established advantages over standard open femoral exposure as a direct consequence of being less invasive and having shorter times to hemostasis and procedure completion. The first multicenter randomized controlled trial designed to assess the safety and efficacy of PEVAR and to compare percutaneous access with standard open femoral exposure was recently published (the PEVAR trial). The PEVAR trial demonstrated that percutaneous endografting is safe, effective, and noninferior to standard open femoral exposure among trained operators. The study reaffirmed the results of several recent single center and nonrandomized studies, demonstrating that percutaneous access facilitated shorter procedures, shorter times to secure hemostasis, and improved quality of life for patients. As PEVAR has gained popularity among patients and physicians, refinements to the technique and patient selection process have been made. There has been growing interest in treating patients with anatomical characteristics previously thought to be unsuitable for PEVAR, such as common femoral artery (CFA) calcifications, scarred groins, small CFA diameter, and high patient body mass index (BMI). However, observance of strict procedural technique and consideration for patient selection criteria remain paramount in achieving acceptable technical success rates with PEVAR.
Collapse
|