Effect of preventing
air intrusion on silent strokes during atrial fibrillation ablation using a mini-basket catheter.
PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2020;
44:71-81. [PMID:
33216388 DOI:
10.1111/pace.14131]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Revised: 11/04/2020] [Accepted: 11/15/2020] [Indexed: 11/28/2022]
Abstract
BACKGROUND
Air bubble intrusion through transseptal sheaths during left atrial (LA) catheter ablation can cause cerebral embolisms, especially when using complex-shape catheters. This study aimed to compare the incidence of silent cerebral events (SCEs) after atrial fibrillation (AF) catheter ablation using a mini-basket catheter (IntellaMap Orion; Boston Scientific) between the following groups: group SP, strict prevention of LA air intrusion and group CP, conventional air intrusion prevention.
METHODS
We enrolled 123 consecutive AF patients (group SP, n = 61 and group CP, n = 62) who underwent brain magnetic resonance imaging after a local-impedance-guided ablation using one mini-basket catheter and one circular mapping catheter. The preventive strategy in group SP included (a) the insertion of the mini-basket catheter into the transseptal sheaths in a container filled with heparinized saline and (b) no exchange of all catheters over the sheaths.
RESULTS
SCEs were detected in 67 patients (54.5%), and the incidence of SCEs did not significantly differ between groups SP and CP (55.7% vs 53.2%; P = .780). A multivariate analysis demonstrated that an older age, non-paroxysmal AF, and radiofrequency (RF) power output were independent positive predictors of SCEs (odds ratios: 1.079, 5.613, and 1.405; P = .005, <.001, and .012). On the follow-up MR imaging, 83.5% of the SCEs in group SP and 87.7% in group CP disappeared (P = .398).
CONCLUSIONS
Strict prevention of LA air intrusion may have no additional effect for reducing the incidence of SCEs after local impedance-guided AF ablation using a mini-basket catheter. An older age, non-paroxysmal AF, and high-power RF applications may increase the risk of SCEs.
Collapse