Reliability of Bioreactance and Pulse-Power Analysis in Measuring Cardiac Index During Open Abdominal Aortic Surgery. J Cardiothorac Vasc Anesth 2024:S1053-0770(24)00097-1. [PMID: 38631929 DOI: 10.1053/j.jvca.2024.02.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 01/30/2024] [Accepted: 02/05/2024] [Indexed: 04/19/2024]
Abstract
OBJECTIVE To investigate the accuracy, precision, and trending ability of noninvasive bioreactance-based Starling SV and the mini invasive pulse-power device LiDCOrapid as compared to thermodilution cardiac output (TDCO) as measured by pulmonary artery catheter when assessing cardiac index (CIx) in the setting of elective open abdominal aortic (AA) surgery. DESIGN A prospective method-comparison study. SETTING Oulu University Hospital, Finland. PARTICIPANTS Forty patients undergoing elective open abdominal aortic surgery. INTERVENTIONS Intraoperative CI measurements were obtained simultaneously with TDCO and the study monitors, resulting in 627 measurement pairs with Starling SV and 497 with LiDCOrapid. MEASUREMENTS AND MAIN RESULTS The Bland-Altman method was used to investigate the agreement among the devices, and four-quadrant plots with error grids were used to assess trending ability. The agreement between TDCO and Starling SV was associated with a bias of 0.18 L/min/m2 (95% confidence interval [CI] = 0.13 to 0.23), wide limits of agreement (LOA = -1.12 to 1.47 L/min/m2), and a percentage error (PE) of 63.7 (95% CI = 52.4-71.0). The agreement between TDCO and LiDCOrapid was associated with a bias of -0.15 L/min/m2 (95% CI = -0.21 to -0.09), wide LOA (-1.56 to 1.37), and a PE of 68.7 (95% CI = 54.9-79.6). The trending ability of neither device was sufficient. CONCLUSION The CI measurements achieved with Starling SV and LiDCOrapid were not interchangeable with TDCO, and the ability to track changes in CI was poor. These results do not support the use of either study device in monitoring CI during open AA surgery.
Collapse
|
2
|
Clinical outcomes of a prospective randomized comparison of bioreactance monitoring versus pulse-contour analysis in a stroke-volume based goal-directed fluid resuscitation protocol in brain-dead organ donors. Clin Transplant 2023; 37:e15110. [PMID: 37615632 DOI: 10.1111/ctr.15110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 06/27/2023] [Accepted: 08/16/2023] [Indexed: 08/25/2023]
Abstract
Eighty percent of brain-dead (BD) organ donors develop hypotension and are frequently hypovolemic. Fluid resuscitation in a BD donor is controversial. We have previously published our 4-h goal-directed stroke volume (SV)-based fluid resuscitation protocol which significantly decreased time on vasopressors and increased transplanting four or more organs. The SV was measured by pulse-contour analysis (PCA) or an esophageal doppler monitor, both of which are invasive. Thoracic bioreactance (BR) is a non-invasive portable technology that measures SV but has not been studied in BD donors. We performed a randomized prospective comparative study of BR versus PCA technology in our fluid resuscitation protocol in BD donors. Eighty-four donors (53.1%) were randomized to BR and 74 donors to PCA (46.8%). The two groups were well matched based on 24 demographic, social, and initial laboratory factors, without any significant differences between them. There was no difference in the intravenous fluid infused over the 4-h study period [BR 2271 ± 823 vs. PCA 2230 ± 962 mL; p = .77]. There was no difference in the time to wean off vasopressors [BR 108.8 ± 61.8 vs. PCA 150.0 ± 68 min p = .07], nor in the number of donors off vasopressors at the end of the protocol [BR 16 (28.6%) vs. PCA 15 (29.4%); p = .92]. There was no difference in the total number of organs transplanted per donor [BR 3.25 ± 1.77 vs. PCA 3.22 ± 1.75; p = .90], nor in any individual organ transplanted. BR was equivalent to PCA in clinical outcomes and provides a simple, non-invasive, portable technology to monitor fluid resuscitation in organ donors.
Collapse
|
3
|
Relationship between the hemodynamic profile and resistant hypertension in pregnant patients with hypertensive crisis. Hypertens Pregnancy 2023; 42:2272176. [PMID: 38059821 DOI: 10.1080/10641955.2023.2272176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 10/07/2023] [Indexed: 12/08/2023]
Abstract
OBJECTIVE Reducing maternal morbidity and mortality has been a challenge for low and middle-income countries, especially in the setting of hypertensive disorders of pregnancy. Improved strategies for treating obstetric patients with resistant hypertension are needed. We sought to explore whether hemodynamic parameters may be used to identify patients that develop resistant hypertension in pregnancy. METHODS Retrospective cohort study among pregnant patients with gestational hypertension or preeclampsia that experienced severe blood pressure elevations. Hemodynamic variables were evaluated, including cardiac output (CO), and total peripheral resistance (TPR). The primary endpoint was resistant hypertension. An exploratory logistic regression was performed to evaluate the association between the hemodynamic profile and the development of resistant hypertension. Adverse maternal and fetal outcomes were additionally described according to the presence of resistant hypertension. RESULTS Fifty-seven patients with severe pregnancy hypertension were included, of whom 34 developed resistant hypertension (59.7%). The resistant hypertension group, in comparison to those without resistant hypertension, presented with a hypodynamic profile characterized by reduced CO < 5 L/min (41.2% vs. 8.7%, p: 0.007), and increased TPR > 1400 dyn-s/cm5 (64.7% vs. 39.1%, p: 0.057). Logistic regression analysis revealed an association between a hypodynamic profile and resistant hypertension (OR 3.252, 95% CI 1.079-9.804; p = 0.035). Newborns of the resistant hypertension group had more frequent low birth weight (<2500 g), low Apgar scores, ICU admissions, and acute respiratory distress syndrome. CONCLUSION Patients experiencing hypertensive crisis during pregnancy and exhibiting a hypodynamic profile (TPR ≥1400 dyn·s/cm5 and CO ≤ 5 L/min) developed higher rates of resistant hypertension.
Collapse
|
4
|
Longitudinal maternal cardiac function in hypertensive disorders of pregnancy. Am J Obstet Gynecol MFM 2023; 5:100824. [PMID: 36464241 DOI: 10.1016/j.ajogmf.2022.100824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 11/21/2022] [Accepted: 11/28/2022] [Indexed: 12/04/2022]
Abstract
BACKGROUND Compared with gestational hypertension, preeclampsia has traditionally been considered the worse end of the spectrum of hypertensive disorders of pregnancy. It is associated with worse pregnancy outcomes and future cardiovascular morbidities. Both hypertensive disorders may be associated with cardiac maladaptation in pregnancy. However, previous studies were limited by small numbers and a paucity of longitudinal data and unaccounted for the contribution of maternal characteristics that can affect hemodynamics. OBJECTIVE This study aimed to assess, in an unselected population, the maternal cardiac adaptation in normotensive and hypertensive pregnancies after controlling for important maternal characteristics that affect maternal cardiac function and the interaction among these covariates. STUDY DESIGN This was a prospective, multicenter longitudinal study of maternal hemodynamics, assessed by a noninvasive bioreactance technology, measured at 11 0/7 to 13 6/7, 19 0/7 to 24 0/7, 30 0/7 to 34 0/7, and 35 0/7 to 37 0/7 weeks of gestation in 3 groups of women. Group 1 was composed of women with preeclampsia (n=45), group 2 was composed of women with gestational hypertension (n=61), and group 3 was composed of normotensive women (n=1643). A multilevel linear mixed-effects model was performed to compare the repeated measures of hemodynamic variables controlling for maternal age, height, weight, weight gain, race, previous obstetrical history, and birthweight. RESULTS After adjusting for confounders that significantly affect maternal hemodynamics, both group 1 and group 2, compared with group 3, had pathologic cardiac adaptation. Group 1, compared with group 3, demonstrated hyperdynamic circulation with significantly higher cardiac output driven by greater stroke volume in the first trimester of pregnancy. As the pregnancies progressed to after 20 0/7 weeks of gestation, this hyperdynamic state transitioned to hypodynamic state with low cardiac output and high peripheral vascular resistance. Group 2, compared with group 3, had no significant differences in cardiac output, stroke volume, and heart rate before 20 0/7 weeks of gestation but thereafter demonstrated a continuous decline in cardiac output and stroke volume, similar to group 1. Both groups 1 and 2, compared with group 3, had persistently elevated mean arterial pressure and uterine artery pulsatility index throughout pregnancy. CONCLUSION After adjusting for confounders that affect maternal hemodynamics in an unselected pregnant population, women with preeclampsia and gestational hypertension, compared with normotensive women, demonstrated similar cardiac maladaptation. This pathologic profile was evident after 20 0/7 weeks of gestation and at least 10 weeks before the clinical manifestation of the disease.
Collapse
|
5
|
Change in End-Tidal Co 2 After Mini-Fluid Challenge to Determine Fluid Responsiveness. Crit Care Explor 2022; 4:e0816. [PMID: 36601564 PMCID: PMC9788972 DOI: 10.1097/cce.0000000000000816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Distributive shock is a major cause of morbidity and mortality in the ICU. IV fluid resuscitation is a vital intervention to improve cardiac output and end-organ perfusion during the initial resuscitation and for those who remain fluid responsive. Noninvasive measures of fluid responsiveness are lacking. The aim of this study is to assess whether changes in end-tidal co2 after mini-fluid challenge, or 250 mL bolus, can predict fluid responsiveness in mechanically ventilated patients with distributive shock. DESIGN Single-center prospective study. SETTING Patients were enrolled from 2019 to 2021 from the medical ICU within a single academic hospital. PATIENTS Thirty-eight patients with paired measurements of fluid responsiveness as determined by bioreactance who were admitted to the ICU with a diagnosis of distributive shock and on mechanical ventilation. INTERVENTIONS Stroke volume index (SVI), cardiac index, heart rate, systolic blood pressure, diastolic blood pressure, mean arterial pressure, and ETco2 were measured before and after completion of a mini-fluid challenge. Test characteristics of change in ETco2 (ΔETco2) greater than or equal to 2 after mini-fluid challenge to determine fluid responsiveness were calculated with percentage change in SVI greater than or equal to 10% used as the reference standard. MEASUREMENTS AND MAIN RESULTS The sensitivity and specificity of a ΔETco2 greater than or equal to 2 mm Hg as a predictor of a change in SVI greater than or equal to 10% following a mini-fluid challenge were 20.0% and 91.3%, respectively. The area under the receiver operating characteristic curve was 0.62. CONCLUSIONS A ΔETco2 greater than or equal to 2 mm Hg after mini-fluid challenge has limited test performance for determining fluid responsiveness in intubated patients with distributive shock.
Collapse
|
6
|
Impact of maternal height, weight at presentation and gestational weight gain on cardiac adaptation in pregnancy. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2022; 60:523-531. [PMID: 35020246 DOI: 10.1002/uog.24858] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 12/20/2021] [Accepted: 12/30/2021] [Indexed: 06/14/2023]
Abstract
OBJECTIVE To compare longitudinal maternal hemodynamic changes throughout gestation between different groups stratified according to weight at presentation and assess the relative influence of height, weight at presentation and gestational weight gain on cardiac adaptation. METHODS This was a prospective, longitudinal study assessing maternal hemodynamics using bioreactance technology at 11 + 0 to 13 + 6, 19 + 0 to 24 + 0, 30 + 0 to 34 + 0 and 35 + 0 to 37 + 0 weeks' gestation. Women were divided into three groups according to maternal weight at presentation at the first visit at 11 + 0 to 13 + 6 weeks: Group 1, < 60.0 kg (n = 421); Group 2, 60.0-79.7 kg (n = 904); Group 3, > 79.7 kg (n = 427). A multilevel linear mixed-effects model was used to compare the repeated measures of hemodynamic variables, correcting for demographics, medical and obstetric history, pregnancy complications, maternal weight and time of evaluation. The linear mixed-effects model was then repeated using maternal height, weight at presentation and gestational weight gain Z-scores, and the standardized coefficients were used to evaluate the relative impact of each of these demographic parameters on longitudinal changes of maternal hemodynamics. RESULTS Compared with Group 1, women in Group 3 demonstrated higher cardiac output (CO), heart rate (HR) and mean arterial pressure (MAP) throughout pregnancy. Groups 2 and 3 had higher stroke volume (SV) than Group 1 at the first visit, but their SV plateaued between the first and second visits and demonstrated an earlier significant decrease from the second visit to the third visit when compared with Group 1. Compared with Groups 1 and 2, there was a higher prevalence of pre-eclampsia, gestational hypertension and gestational diabetes in Group 3. Maternal height was the most important contributor to CO, peripheral vascular resistance (PVR), SV and HR, while weight at presentation was the most important contributor to MAP. Gestational weight gain was the second most important characteristic influencing the longitudinal changes of PVR and SV. CONCLUSIONS Women with greater weight at presentation have a pathological hemodynamic profile, with higher CO, HR and MAP compared to women with lower weight at presentation. Height is the main determinant of CO, SV, HR and PVR, weight is the main determinant of MAP, and gestational weight gain is the second most important determinant of SV and PVR. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
|
7
|
Accuracy and Trending Ability of Electrical Biosensing Technology for Non-invasive Cardiac Output Monitoring in Neonates: A Systematic Qualitative Review. Front Pediatr 2022; 10:851850. [PMID: 35372144 PMCID: PMC8968571 DOI: 10.3389/fped.2022.851850] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 02/14/2022] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Electrical biosensing technology (EBT) is an umbrella term for non-invasive technology utilizing the body's fluctuating resistance to electrical current flow to estimate cardiac output. Monitoring cardiac output in neonates may allow for timely recognition of hemodynamic compromise and allow for prompt therapy, thereby mitigating adverse outcomes. For a new technology to be safely used in the clinical environment for therapeutic decisions, it must be proven to be accurate, precise and be able to track temporal changes. The aim of this systematic review was to identify and analyze studies that describe the accuracy, precision, and trending ability of EBT to non-invasively monitor Left ventricular cardiac output and/or stroke volume in neonates. METHODS A qualitative systematic review was performed. Studies were identified from PubMed NCBI, SCOPUS, and EBSCOHost up to November 2021, where EBT technologies were analyzed in neonates, in comparison to a reference technology. Outcome measures were bias, limits of agreement, percentage error for agreement studies and data from 4-quadrant and polar plots for trending studies. Effect direction plots were used to present results. RESULTS Fifteen neonatal studies were identified, 14 for agreement and 1 for trending analysis. Only thoracic electrical biosensing technology (TEBT), with transthoracic echocardiography (TTE) as the comparator, studies were available for analyzes. High heterogeneity existed between studies. An equal number of studies showed over- and underestimation of left ventricular output parameters. All studies showed small bias, wide limits of agreement, with most studies having a percentage error >30%. Sub-analyses for respiratory support mode, cardiac anomalies and type of technology showed similar results. The single trending study showed poor concordance, high angular bias, and poor angular concordance. DISCUSSION Overall, TEBT shows reasonable accuracy, poor precision, and non-interchangeability with TTE. However, high heterogeneity hampered proper analysis. TEBT should be used with caution in the neonatal population for monitoring and determining therapeutic interventions. The use of TEBT trend monitoring has not been sufficiently studied and requires further evaluation in future trials.
Collapse
|
8
|
Reliability of Bioreactance and Pulse-Power Analysis in Measuring Cardiac Index in Patients Undergoing Cardiac Surgery With Cardiopulmonary Bypass. J Cardiothorac Vasc Anesth 2021; 36:2446-2453. [PMID: 35027295 DOI: 10.1053/j.jvca.2021.11.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 11/21/2021] [Accepted: 11/29/2021] [Indexed: 11/11/2022]
Abstract
OBJECTIVES Less-invasive and continuous cardiac output monitors recently have been developed to monitor patient hemodynamics. The aim of this study was to compare the accuracy, precision, and trending ability of noninvasive bioreactance-based Starling SV and miniinvasive pulse-power device LiDCOrapid to bolus thermodilution technique with a pulmonary artery catheter (TDCO) when measuring cardiac index in the setting of cardiac surgery with cardiopulmonary bypass (CPB). DESIGN A prospective method-comparison study. SETTING Oulu University Hospital, Finland. PARTICIPANTS Twenty patients undergoing cardiac surgery with CPB. INTERVENTIONS Cardiac index measurements were obtained simultaneously with TDCO intraoperatively and postoperatively, resulting in 498 measurements with Starling SV and 444 with LiDCOrapid. MEASUREMENTS AND MAIN RESULTS The authors used the Bland-Altman method to investigate the agreement between the devices and four-quadrant plots with error grids to assess the trending ability. The agreement between TDCO and Starling SV was qualified with a bias of 0.43 L/min/m2 (95% confidence interval [CI], 0.37-0.50), wide limits of agreement (LOA, -1.07 to 1.94 L/min/m2), and a percentage error (PE) of 66.3%. The agreement between TDCO and LiDCOrapid was qualified, with a bias of 0.22 L/min/m2 (95% CI 0.16-0.27), wide LOA (-0.93 to 1.43), and a PE of 53.2%. With both devices, trending ability was insufficient. CONCLUSION The reliability of bioreactance-based Starling SV and pulse-power analyzer LiDCOrapid was not interchangeable with TDCO, thus limiting their usefulness in cardiac surgery with CPB.
Collapse
|
9
|
Effect of maternal age on cardiac adaptation in pregnancy. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2021; 58:285-292. [PMID: 33592675 DOI: 10.1002/uog.23614] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 02/02/2021] [Accepted: 02/08/2021] [Indexed: 06/12/2023]
Abstract
OBJECTIVE To compare longitudinal maternal hemodynamic changes throughout gestation between different age groups. METHODS This was a prospective longitudinal study assessing maternal hemodynamics using a bioreactance technique at 11 + 0 to 13 + 6, 19 + 0 to 24 + 0, 30 + 0 to 34 + 0 and 35 + 0 to 37 + 0 weeks' gestation. Women were divided into four groups according to maternal age at the first visit at 11 + 0 to 13 + 6 weeks: Group 1, < 25.0 years; Group 2, 25.0-30.0 years; Group 3, 30.1-34.9 years; and Group 4, ≥ 35.0 years. A multilevel linear mixed-effects model was performed to compare the repeat measurements of hemodynamic variables, correcting for demographics, medical and obstetric history, pregnancy complications, maternal age and gestational-age window. RESULTS The study population included 254 women in Group 1, 442 in Group 2, 618 in Group 3 and 475 in Group 4. Younger women (Group 1) had the highest cardiac output (CO) and lowest peripheral vascular resistance (PVR), and older women (Group 4) had the lowest CO and highest PVR throughout pregnancy. The higher CO seen in younger women was achieved through an increase in heart rate alone and not with a concomitant rise in stroke volume. Although the youngest age group demonstrated an apparently more favorable hemodynamic profile, it had the highest incidence of a small-for-gestational-age neonate. There was no significant difference between the groups in the incidence of pre-eclampsia. CONCLUSION Age-specific differences in maternal hemodynamic adaptation do not explain the differences in the incidence of a small-for-gestational-age neonate between age groups. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
|
10
|
Maternal cardiac adaptation and fetal growth. Am J Obstet Gynecol 2021; 224:601.e1-601.e18. [PMID: 33347843 DOI: 10.1016/j.ajog.2020.12.1199] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 11/02/2020] [Accepted: 12/15/2020] [Indexed: 01/15/2023]
Abstract
BACKGROUND Pregnancies with small-for-gestational-age fetuses are at increased risk of adverse maternal-fetal outcomes. Previous studies examining the relationship between maternal hemodynamics and fetal growth were mainly focused on high-risk pregnancies and those with fetuses with extreme birthweights, such as less than the 3rd or 10th percentile and assumed a similar growth pattern in fetuses above the 10th percentile throughout gestation. OBJECTIVE This study aimed to evaluate the trends in maternal cardiac function, fetal growth, and oxygenation with advancing gestational age in a routine obstetrical population and all ranges of birthweight percentiles. STUDY DESIGN This was a prospective, longitudinal study assessing maternal cardiac output and peripheral vascular resistance by bioreactance at 11+0 to 13+6, 19+0 to 24+0, 30+0 to 34+0, and 35+0 to 37+0 weeks' gestation, sonographic estimated fetal weight in the last 3 visits and the ratio of the middle cerebral artery by umbilical artery pulsatility indices or cerebroplacental ratio in the last 2 visits. Women were divided into the following 5 groups according to birthweight percentile: group 1, <10th percentile (n=261); group 2, 10 to 19.9 percentile (n=180); group 3, 20 to 29.9 percentile (n=189); group 4, 30 to 69.9 percentile (n=651); and group 5, ≥70th percentile (n=508). The multilevel linear mixed-effects model was performed to compare the repeated measures of hemodynamic variables and z scores of the estimated fetal weight and cerebroplacental ratio. RESULTS In visit 2, compared with visit 1, in all groups, cardiac output increased, and peripheral vascular resistance decreased. At visit 3, groups 1, 2, and 3, compared with 4 and 5, demonstrated an abrupt decrease in cardiac output and increase in peripheral vascular resistance. From visit 2, group 1 had a constant decline in estimated fetal weight, coinciding with the steepest decline in maternal cardiac output and rise in peripheral vascular resistance. In contrast, in groups 4 and 5, the estimated fetal weight had a stable or accelerative pattern, coinciding with the greatest increase in cardiac output and lowest peripheral vascular resistance. Groups 2 and 3 showed a stable growth pattern with intermediate cardiac output and peripheral vascular resistance. Increasing birthweight was associated with higher cerebroplacental ratio. Groups 3, 4, and 5 had stable cerebroplacental ratio across visits 3 and 4, whereas groups 1 and 2 demonstrated a significant decline (P<.001). CONCLUSION In a general obstetrical population, maternal cardiac adaptation at 32 weeks' gestation parallels the pattern of fetal growth and oxygenation; babies with birthweight<20th percentile have progressive decline in fetal cerebroplacental ratio, decline in maternal cardiac output, and increase in peripheral vascular resistance.
Collapse
|
11
|
Noninvasive Assessment of Cardiac Output in Advanced Heart Failure and Heart Transplant Candidates Using the Bioreactance Method. J Cardiothorac Vasc Anesth 2020; 35:1776-1781. [PMID: 33059979 DOI: 10.1053/j.jvca.2020.09.109] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2020] [Revised: 08/18/2020] [Accepted: 09/16/2020] [Indexed: 11/11/2022]
Abstract
OBJECTIVES The aim of the present study was to assess the validity and trending ability of the bioreactance method in estimating cardiac output at rest and in response to stress in advanced heart failure patients and heart transplant candidates. DESIGN This was a prospective single-center study. SETTING This study was conducted at the heart transplant center at the Freeman Hospital, Newcastle upon Tyne, UK. PARTICIPANTS Eighteen patients with advanced chronic heart failure due to reduced left ventricular ejection fraction (19 ± 7%), and peak oxygen consumption 12.3 ± 3.9 mL/kg/min. INTERVENTIONS Participants underwent right heart catheterization using the Swan-Ganz catheter. MEASUREMENTS AND MAIN RESULTS Cardiac output was measured simultaneously using thermodilution and bioreactance at rest and during active straight leg raise test to volitional exertion. There was no significant difference in cardiac index values obtained by the thermodilution and bioreactance methods (2.26 ± 0.59 v 2.38 ± 0.50 L/min, p > 0.05) at rest and peak straight leg raise test (2.92 ± 0.77 v 3.01 ± 0.66 L/min, p > 0.05). In response to active leg raise test, thermodilution cardiac output increased by 22% and bioreactance by 21%. There was also a strong relationship between cardiac outputs from both methods at rest (r = 0.88, p < 0.01) and peak straight leg raise test (r = 0.92, p < 0.01). Cartesian plot analysis showed good trending ability of bioreactance compared with thermodilution (concordance rate = 93%) CONCLUSIONS: `Cardiac output measured by the bioreactance method is comparable to that from the thermodilution method. Bioreactance method may be used in clinical practice to assess hemodynamics and improve management of advanced heart failure patients undergoing heart transplant assessment.
Collapse
|
12
|
Should we overcome the resistance to bioelectrical impedance in heart failure? Expert Rev Med Devices 2020; 17:785-794. [PMID: 32658589 DOI: 10.1080/17434440.2020.1791701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
INTRODUCTION Heart failure is associated with increased neurohormonal activation that results in changes in body composition including volume overload and the loss of skeletal muscle, body fat, and bone density. Bioelectrical impedance measures body composition based on the conduction of electrical current through body fluids. AREAS COVERED The PubMed and Scopus databases were reviewed up to the third week of June 2020. Cross-sectional studies, retrospective observational studies, prospective observational studies, and randomized controlled trials have examined numerous bioelectrical impedance monitoring strategies to guide the diagnosis, prognosis, and treatment of heart failure. These monitoring strategies include intrathoracic impedance, lung impedance, bioelectrical impedance vector analysis, leg bioelectrical impedance, and thoracic bioreactance. EXPERT COMMENTARY Based on the current evidence, more studies are needed to validate bioelectrical impedance in heart failure. Lung impedance appears to be useful for guiding heart failure treatment in patients with ST-elevation myocardial infarction and improving outcomes in outpatients with heart failure. Furthermore, bioelectrical impedance has potential as a noninvasive, quantitative heart failure variable for population-based research.
Collapse
|
13
|
Effect of race on longitudinal central hemodynamics in pregnancy. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2020; 56:37-43. [PMID: 31692154 DOI: 10.1002/uog.21914] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 10/21/2019] [Accepted: 10/24/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVE To compare central hemodynamics between white, black and Asian women in pregnancy. METHODS This was a prospective, longitudinal study of maternal central hemodynamics in white, black and Asian women with a singleton pregnancy, assessed using a bioreactance method at 11 + 0 to 13 + 6, 19 + 0 to 24 + 0, 30 + 0 to 34 + 0 and 35 + 0 to 37 + 0 weeks' gestation. At each visit, cardiac output (CO), stroke volume (SV), heart rate (HR), peripheral vascular resistance (PVR) and mean arterial pressure were recorded. Multilevel linear mixed-effects analysis was performed to compare the repeated measures of the cardiac variables between white, black and Asian women, controlling for maternal characteristics, medical history and medication use. RESULTS The study population included 1165 white, 247 black and 116 Asian women. CO increased with gestational age to a peak at 32 weeks and then decreased; the highest CO was observed in white women and the lowest in Asian women. SV initially increased after the first visit but subsequently declined with gestational age in white women, decreased with gestational age in black women and remained static in Asian women. In all three study groups, HR increased with gestational age until 32 weeks and then remained constant; HR was highest in black women and lowest in white women. PVR showed a reversed pattern to that of CO; the highest values were in Asian women and the lowest in white women. The least favorable hemodynamic profile, which was observed in black and Asian women, was reflected in higher rates of a small-for-gestational-age infant. CONCLUSIONS There are race-specific differences in maternal cardiac adaptation to pregnancy. White women have the most favorable cardiac adaptation by increasing SV and HR, achieving the highest CO and lowest PVR. In contrast, black and Asian women have lower CO and higher PVR than do white women, with CO increasing through a rise in HR due to declining or static SV. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
|
14
|
Clinical validation of bioreactance for the measurement of cardiac output in pregnancy. Anaesthesia 2020; 75:1307-1313. [PMID: 32469423 DOI: 10.1111/anae.15110] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/30/2020] [Indexed: 11/27/2022]
Abstract
Maternal cardiac dysfunction is associated with pre-eclampsia, fetal growth restriction and haemodynamic instability during obstetric anaesthesia. There is growing interest in the use of non-invasive cardiac output monitoring to guide antihypertensive and fluid therapies in obstetrics. The aim of this study was to validate thoracic bioreactance using the NICOM® instrument against transthoracic echocardiography in pregnant women, and to assess the effects of maternal characteristics on the absolute difference of stroke volume, cardiac output and heart rate. We performed a prospective study involving women with singleton pregnancies in each trimester. We recruited 56 women who were between 11 and 14 weeks gestation, 57 between 20 and 23 weeks, and 53 between 35 and 37 weeks. Cardiac output was assessed repeatedly and simultaneously over 5 min in the left lateral position with NICOM and echocardiography. The performance of NICOM was assessed by calculating bias, 95% limits of agreement and mean percentage difference relative to echocardiography. Multivariate regression analysis evaluated the effect of maternal characteristics on the absolute difference between echocardiography and NICOM. The mean percentage difference of cardiac output measurements between the two methods was ±17%, with mean bias of -0.13 l.min-1 and limits of agreement of -1.1 to 0.84; stroke volume measurements had a mean percentage difference of ±15%, with a mean bias of -0.8 ml (-10.9 to 12.6); and heart rate measurements had a mean percentage difference of ±6%, with a mean bias of -2.4 beats.min-1 (-6.9 to 2.0). Similar results were found when the analyses were confined to each individual trimester. The absolute difference between NICOM and echocardiography was not affected by maternal age, weight, height, race, systolic or diastolic blood pressure. In conclusion, NICOM demonstrated good agreement with echocardiography, and can be used in pregnancy for the measurement of cardiac function.
Collapse
|
15
|
Abstract
Circulatory monitoring is currently limited to heart rate and blood pressure assessment in the majority of neonatal units globally. Non-invasive cardiac output monitoring (NiCO) in term and preterm neonates is increasing, where it has the potential to enhance our understanding and management of overall circulatory status. In this narrative review, we summarized 33 studies including almost 2,000 term and preterm neonates. The majority of studies evaluated interchangeability with echocardiography. Studies were performed in various clinical settings including the delivery room, patent ductus arteriosus assessment, patient positioning, red blood cell transfusion, and therapeutic hypothermia for hypoxic ischemic encephalopathy. This review presents an overview of NiCO in neonatal care, focusing on technical and practical aspects as well as current available evidence. We discuss potential goals for future research.
Collapse
|
16
|
The effect of parity on longitudinal maternal hemodynamics. Am J Obstet Gynecol 2019; 221:249.e1-249.e14. [PMID: 30951684 DOI: 10.1016/j.ajog.2019.03.027] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Revised: 03/24/2019] [Accepted: 03/27/2019] [Indexed: 12/16/2022]
Abstract
BACKGROUND Parous women have a lower risk for pregnancy complications, such as preeclampsia or delivery of small-for-gestational-age neonates. However, parous women are a heterogeneous group of patients because they contain a low-risk cohort with previously uncomplicated pregnancies and a high-risk cohort with previous pregnancies complicated by preeclampsia and/or small for gestational age. Previous studies examining the effect of parity on maternal hemodynamics, including cardiac output and peripheral vascular resistance, did not distinguish between parous women with and without a history of preeclampsia or small for gestational age and reported contradictory results. OBJECTIVE The objective of the study was to compare maternal hemodynamics in nulliparous women and in parous women with and without previous preeclampsia and/or small for gestational age. STUDY DESIGN This was a prospective, longitudinal study of maternal hemodynamics, assessed by a bioreactance method, measured at 11+0 to 13+6, 19+0 to 24+0, 30+0 to 34+0, and 35+0 to 37+0 weeks' gestation in 3 groups of women. Group 1 was composed of parous women without a history of preeclampsia and/or small for gestational age (n = 632), group 2 was composed of nulliparous women (n = 829), and group 3 was composed of parous women with a history of preeclampsia and/or small for gestational age (n = 113). A multilevel linear mixed-effects model was performed to compare the repeated measures of hemodynamic variables controlling for maternal characteristics, medical history, and development of preeclampsia or small for gestational age in the current pregnancy. RESULTS In groups 1 and 2, cardiac output increased with gestational age to a peak at 32 weeks and peripheral vascular resistance showed a reversed pattern with its nadir at 32 weeks; in group 1, compared with group 2, there was better cardiac adaptation, reflected in higher cardiac output and lower peripheral vascular resistance. In group 3 there was a hyperdynamic profile of higher cardiac output and lower peripheral vascular resistance at the first trimester followed by an earlier sharp decline of cardiac output and increase of peripheral vascular resistance from midgestation. The incidence of preeclampsia and small for gestational age was highest in group 3 and lowest in group 1. CONCLUSION There are parity-specific differences in maternal cardiac adaptation in pregnancy.
Collapse
|
17
|
Maternal hemodynamics in screen-positive and screen-negative women of the ASPRE trial. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2019; 54:51-57. [PMID: 30246326 DOI: 10.1002/uog.20125] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Revised: 09/11/2018] [Accepted: 09/13/2018] [Indexed: 06/08/2023]
Abstract
OBJECTIVE To compare maternal hemodynamics and perinatal outcome, in pregnancies that do not develop pre-eclampsia (PE) or deliver a small-for-gestational-age (SGA) neonate, between those identified at 11-13 weeks' gestation as being screen positive or negative for preterm PE, by a combination of maternal factors, mean arterial pressure, uterine artery pulsatility index, serum placental growth factor and pregnancy associated plasma protein-A. METHODS This was a prospective longitudinal cohort study of maternal cardiovascular function, assessed using a bioreactance method, in women undergoing first-trimester screening for PE. Maternal hemodynamics and perinatal outcome were compared between screen-positive and screen-negative women who did not have a medical comorbidity, did not develop PE or pregnancy-induced hypertension and delivered at term a live neonate with birth weight between the 5th and 95th percentiles. A multilevel linear mixed-effects model was used to compare the repeated measures of cardiac variables, controlling for maternal characteristics. RESULTS The screen-negative group (n = 926) had normal cardiac function changes across gestation, whereas the screen-positive group (n = 170) demonstrated static or reduced cardiac output and stroke volume and higher mean arterial pressure and peripheral vascular resistance with advancing gestation. In the screen-positive group, compared with screen-negative women, birth-weight Z-score was shifted toward lower values, with prevalence of delivery of a neonate below the 35th , 30th or 25th percentile being about 70% higher, and the rate of operative delivery for fetal distress in labor also being higher. CONCLUSION Women who were screen positive for impaired placentation, even though they did not develop PE or deliver a SGA neonate, had pathological cardiac adaptation in pregnancy and increased risk of adverse perinatal outcome. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
|
18
|
Non-Invasive Monitoring of Cardiac Output in Critical Care Medicine. Front Med (Lausanne) 2017; 4:200. [PMID: 29230392 PMCID: PMC5715400 DOI: 10.3389/fmed.2017.00200] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2017] [Accepted: 11/02/2017] [Indexed: 12/21/2022] Open
Abstract
Critically ill patients require close hemodynamic monitoring to titrate treatment on a regular basis. It allows administering fluid with parsimony and adjusting inotropes and vasoactive drugs when necessary. Although invasive monitoring is considered as the reference method, non-invasive monitoring presents the obvious advantage of being associated with fewer complications, at the expanse of accuracy, precision, and step-response change. A great many methods and devices are now used over the world, and this article focuses on several of them, providing with a brief review of related underlying physical principles and validation articles analysis. Reviewed methods include electrical bioimpedance and bioreactance, respiratory-derived cardiac output (CO) monitoring technique, pulse wave transit time, ultrasound CO monitoring, multimodal algorithmic estimation, and inductance thoracocardiography. Quality criteria with which devices were reviewed included: accuracy (closeness of agreement between a measurement value and a true value of the measured), precision (closeness of agreement between replicate measurements on the same or similar objects under specified conditions), and step response change (delay between physiological change and its indication). Our conclusion is that the offer of non-invasive monitoring has improved in the past few years, even though further developments are needed to provide clinicians with sufficiently accurate devices for routine use, as alternative to invasive monitoring devices.
Collapse
|
19
|
Evaluation of cardiac output by bioreactance technique in patients undergoing liver transplantation. ACTA ACUST UNITED AC 2016; 54:57-61. [PMID: 27461188 DOI: 10.1016/j.aat.2016.06.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Revised: 06/07/2016] [Accepted: 06/13/2016] [Indexed: 11/27/2022]
Abstract
BACKGROUND This study compared the cardiac output (CO) obtained from PiCCO with that obtained from the noninvasive NICOM method. METHODS Twenty-one cirrhotic patients receiving liver transplantation were enrolled. During the operation, their CO was measured by the PiCCO system via the thermodilution method as the standard and by the NICOM method. Two parameters including cardiac index (CI) and stroke volume index (SVI) were collected simultaneously at three phases during the surgery including the dissection phase (T1), the anhepatic phase (T2), and the reperfusion phase (T3). Correlation, Bland and Altman methods, and linear mixed model were used to evaluate the monitoring ability of both systems. RESULTS Poor correlation was noted between the data measured by NICOM and PiCCO; the correlation coefficients for CI and SVI measured between the two systems were 0.32 and 0.39, respectively. Bland and Altman analysis showed the percentage error of CI as 63.7%, and that of SVI as 66.6% for NICOM compared to PiCCO. Using the linear mixed model, the CI and SVI measured using NICOM were significantly higher than those using PiCCO (estimated regression coefficient 0.92 and 10.77, both p < 0.001). Mixed model analysis showed no differences between the trends of CI and SVI measured by the two methods. CONCLUSIONS NICOM provided a comparable CI and SVI trend when compared to the gold standard PiCCO, but it raises concerns as an effective CO monitor because of its tendency to overestimate CI and SVI especially during the state of high cardiac output.
Collapse
|
20
|
Pressure recording analytical method and bioreactance for stroke volume index monitoring during pediatric cardiac surgery. Paediatr Anaesth 2015; 25:143-9. [PMID: 24491036 DOI: 10.1111/pan.12360] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/03/2014] [Indexed: 12/30/2022]
Abstract
BACKGROUND It is currently uncertain which hemodynamic monitoring device reliably measures stroke volume and tracks cardiac output changes in pediatric cardiac surgery patients. OBJECTIVE To evaluate the difference between stroke volume index (SVI) measured by pressure recording analytical method (PRAM) and bioreactance and their ability to track changes after a therapeutic intervention. METHODS A single-center prospective observational cohort study in children undergoing cardiac surgery with cardiopulmonary bypass (CPB) was conducted. Twenty children below 20 kg with median (interquartile range) weight of 5.3 kg (4.1-7.8) and age of 6 months (3-20) were enrolled. Data were collected after anesthesia induction, at the end of CPB, before fluid administration and after fluid administration. Overall, median-IQR PRAM SVI values (23 ml·m(-2), 19-27) were significantly higher than bioreactance SVI (15 ml·m(-2), 12-25, P = 0.0001). Correlation (r(2) ) between the two methods was 0.15 (P = 0.0003). The mean difference between the measurements (bias) was 5.7 ml·m(-2) with a standard deviation of 9.6 (95% limits of agreement ranged from -13 to 24 ml·m(-2)). Percentage error was 91.7%. Baseline SVI appeared to be similar, but PRAM SVI was systematically greater than bioreactance thereafter, with the highest gap after the fluid loading phase: 13 (12-18) ml·m(-2) vs. 23 (19-25) ml·m(-2), respectively, P = 0.0013. A multivariable regression model showed that a significant independent inverse correlation with patients' body weight predicted the CI difference between the two methods after fluid challenge (β coefficient -0.12, P = 0.013). CONCLUSIONS Pressure recording analytical method and bioreactance provided similar SVI estimation at stable hemodynamic conditions, while bioreactance SVI values appeared significantly lower than PRAM at the end of CPB and after fluid replacement.
Collapse
|
21
|
Noninvasive cardiac output monitoring using bioreactance-based technique in pediatric patients with or without ventricular septal defect during anesthesia: in comparison with echocardiography. Paediatr Anaesth 2015; 25:167-73. [PMID: 25039420 DOI: 10.1111/pan.12492] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/26/2014] [Indexed: 01/14/2023]
Abstract
BACKGROUND We evaluated the use of bioreactance-based noninvasive cardiac output (CO) monitoring technique (NICOM(™), CO(NICOM)) in pediatric patients with or without ventricular septal defect (VSD) during anesthesia induction to determine its agreement with the measurements assessed by echocardiography (echo, CO(ECHO)). METHODS Twenty-eight pediatric patients with normal heart anatomy (group NHA) and 32 with isolated ventricular septal defects (group VSD) were included in this study. The cardiac output was measured simultaneously in minute-by-minute using NICOM and echo (Simpson's rule) during anesthesia induction and intubation. Linear regression and revised Bland-Altman analyses were performed to evaluate the agreement by comparing the paired CO results. The mean percent error ((CO(ECHO)-CO(NICOM))/CO(ECHO) × 100%) was used to assess the impact of congenital heart disease on the agreement. RESULTS The measurements of CO by NICOM and echo techniques were highly correlated in group NHA (γ = 0.96, P < 0.005) and VSD (γ = 0.84, P < 0.005). The mean bias (CO(ECHO) - CO(NICOM)) between the two methods was 0.03 and 0.31 l·min(-1) with the limits of agreement (LOA) -0.29 to +0.35 l·min(-1) and -0.44 to +1.05 l·min(-1), which include 96.9% (31/32) and 89.3% (25/28) of all patients' different data in group NHA and VSD, respectively. The median percent errors were significantly lower at all time points in group NHA than those in group VSD (all P < 0.05). CONCLUSION In children without heart defects, the CO measured by NICOM shows a good agreement with the echo during anesthesia induction. The NICOM technique underestimates echo although a strong correlation exists between two methods in children with ventricular septal defect.
Collapse
|