1
|
Al Mukahal FHH, Abazid MA, Sobhy M. Investigating Electromechanical Buckling Response of FG-GPL-Reinforced Piezoelectric Doubly Curved Shallow Shells Embedded in an Elastic Substrate. Materials (Basel) 2023; 16:2975. [PMID: 37109811 PMCID: PMC10141238 DOI: 10.3390/ma16082975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2023] [Revised: 03/30/2023] [Accepted: 04/06/2023] [Indexed: 06/19/2023]
Abstract
This work reports the investigations of the electric potential impacts on the mechanical buckling of the piezoelectric nanocomposite doubly curved shallow shells reinforced by functionally gradient graphene platelets (FGGPLs). A four-variable shear deformation shell theory is utilized to describe the components of displacement. The present nanocomposite shells are presumed to be rested on an elastic foundation and subject to electric potential and in-plane compressive loads. These shells are composed of several bonded layers. Each layer is composed of piezoelectric materials strengthened by uniformly distributed GPLs. The Halpin-Tsai model is employed to calculate the Young's modulus of each layer, whereas Poisson's ratio, mass density, and piezoelectric coefficients are evaluated based on the mixture rule. The graphene components are graded from one layer to another according to four different piecewise laws. The stability differential equations are deduced based on the principle of virtual work. To test the validity of this work, the current mechanical buckling load is analogized with that available in the literature. Several parametric investigations have been performed to demonstrate the effects of the shell geometry elastic foundation stiffness, GPL volume fraction, and external electric voltage on the mechanical buckling load of the GPLs/piezoelectric nanocomposite doubly curved shallow shells. It is found that the buckling load of GPLs/piezoelectric nanocomposite doubly curved shallow shells without elastic foundations is reduced by increasing the external electric voltage. Moreover, by increasing the elastic foundation stiffness, the shell strength is enhanced, leading to an increase in the critical buckling load.
Collapse
Affiliation(s)
- Fatemah H. H. Al Mukahal
- Department of Mathematics and Statistics, College of Science, King Faisal University, P.O. Box 400, Al-Ahsa 31982, Saudi Arabia
| | - Mohammad Alakel Abazid
- Department of Mathematics and Statistics, College of Science, King Faisal University, P.O. Box 400, Al-Ahsa 31982, Saudi Arabia
| | - Mohammed Sobhy
- Department of Mathematics and Statistics, College of Science, King Faisal University, P.O. Box 400, Al-Ahsa 31982, Saudi Arabia
- Department of Mathematics, Faculty of Science, Kafrelsheikh University, Kafrelsheikh 33516, Egypt
| |
Collapse
|
2
|
Pringels L, Vanden Bossche L, Wezenbeek E, Burssens A, Vermue H, Victor J, Chevalier A. Intratendinous pressure changes in the Achilles tendon during stretching and eccentric loading: Implications for Achilles tendinopathy. Scand J Med Sci Sports 2022; 33:619-630. [PMID: 36517927 DOI: 10.1111/sms.14285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Revised: 10/29/2022] [Accepted: 12/02/2022] [Indexed: 12/23/2022]
Abstract
Mechanical overload is considered the main cause of Achilles tendinopathy. In addition to tensile loads, it is believed that the Achilles tendon may also be exposed to compressive loads. However, data on intratendinous pressures are lacking, and consequently, their role in the pathophysiology of tendinopathy is still under debate. Therefore, we aimed to evaluate the intratendinous pressure changes in the Achilles tendon during stretching and eccentric loading. Twelve pairs of human cadaveric legs were mounted in a testing rig, and a miniature pressure catheter was placed through ultrasound-guided insertion in four different regions of the Achilles tendon: the insertion (superficial and deep layers), mid-portion, and proximal portion. Intratendinous pressure was measured during three simulated loading conditions: a bent-knee calf stretch, a straight-knee calf stretch, and an eccentric heel-drop. It was found that the intratendinous pressure increased exponentially in both the insertion and mid-portion regions of the Achilles tendon during each loading condition (p < 0.001). The highest pressures were consistently found in the deep insertion region (p < 0.001) and during the eccentric heel-drop (p < 0.001). Pressures in the mid-portion were also significantly higher than in the proximal portion (p < 0.001). These observations offer novel insights and support a role for compression in the pathophysiology of Achilles tendinopathy by demonstrating high intratendinous pressures at regions where Achilles tendinopathy typically occurs. To what extent managing intratendinous pressure might be successful in patients with Achilles tendinopathy by, for example, avoiding excessive stretching, modifying exercise therapy, and offering heel lifts requires further investigation.
Collapse
Affiliation(s)
- Lauren Pringels
- Department of Physical and Rehabilitation Medicine, Ghent University Hospital, Ghent, Belgium.,Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent, Belgium
| | - Luc Vanden Bossche
- Department of Physical and Rehabilitation Medicine, Ghent University Hospital, Ghent, Belgium.,Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent, Belgium
| | - Evi Wezenbeek
- Department of Rehabilitation Sciences and Physiotherapy, Ghent University, Ghent, Belgium
| | - Arne Burssens
- Department of Orthopaedic Surgery, Ghent University Hospital, Ghent, Belgium
| | - Hannes Vermue
- Department of Orthopaedic Surgery, Ghent University Hospital, Ghent, Belgium
| | - Jan Victor
- Department of Orthopaedic Surgery, Ghent University Hospital, Ghent, Belgium
| | - Amelie Chevalier
- Department of Electromechanical, systems and metals engineering, Ghent University, Ghent, Belgium.,Department of Electromechanics, CoSysLab, University of Antwerp, Antwerp, Belgium.,AnSyMo/Cosys, Flanders Make, the strategic research centre for the manufacturing industry, Antwerp, Belgium
| | | |
Collapse
|
3
|
LePage EC, Stoker AM, Kuroki K, Cook JL. Effects of cyclic compression on intervertebral disc metabolism using a whole-organ rat tail model. J Orthop Res 2021; 39:1945-1954. [PMID: 33073417 DOI: 10.1002/jor.24886] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 10/07/2020] [Accepted: 10/14/2020] [Indexed: 02/04/2023]
Abstract
Many factors contribute to the development and progression of intervertebral disc (IVD) degeneration. This study was designed to assess the effects of compressive load magnitude on IVD metabolism. It was hypothesized that as load magnitude increased, there would be a significant increase in release of proinflammatory and degradative biomarkers, and a significant decrease in tissue proteoglycan (GAG) and collagen contents compared with unloaded controls. IVD whole organ functional spinal units (FSU) consisting of cranial and caudal body halves, cartilage endplates, and IVD (n = 36) were harvested from the tails of six Sprague Dawley rats, and FSUs were cultured at 0.0 MPa, 0.5 MPa, or 1.0 MPa at 0.5 Hz for 3 days. After culture, media were collected for biomarker analysis and FSUs were analyzed for extracellular matrix composition. Significant differences were determined using a one-way analysis of variance or Kruskal-Wallis test and post hoc analyses. Media concentrations of IFN-γ, IL-6, IL-1β, and MMP-8 were significantly higher in the 0.5 MPa compared with the 0.0 MPa group. Media concentrations of PGE2 and TIMP-1 were significantly higher in the 1.0 MPa group compared with the 0.0 MPa group, and media PGE2 was significantly higher in the 1.0 MPa group compared with the 0.5 MPa group. Media GAG content was significantly higher in the 1.0 MPa group compared with the 0.0 MPa group, and percent GAG in the tissue was significantly lower in 0.5 MPa and 1.0 MPa groups compared with the 0.0 MPa group. Clinical Significance: These data suggest that there are magnitude-dependent inflammatory and degradative IVD responses to cyclic loading, which may contribute to IVD degeneration.
Collapse
Affiliation(s)
- Emma C LePage
- Department of Orthopaedic Surgery, University of Missouri, Columbia, Missouri, USA.,Department of Orthopaedic Surgery, Thompson Laboratory for Regenerative Orthopaedics, University of Missouri, Columbia, Missouri, USA
| | - Aaron M Stoker
- Department of Orthopaedic Surgery, University of Missouri, Columbia, Missouri, USA.,Department of Orthopaedic Surgery, Thompson Laboratory for Regenerative Orthopaedics, University of Missouri, Columbia, Missouri, USA
| | - Keiichi Kuroki
- Department of Orthopaedic Surgery, Thompson Laboratory for Regenerative Orthopaedics, University of Missouri, Columbia, Missouri, USA
| | - James L Cook
- Department of Orthopaedic Surgery, University of Missouri, Columbia, Missouri, USA.,Department of Orthopaedic Surgery, Thompson Laboratory for Regenerative Orthopaedics, University of Missouri, Columbia, Missouri, USA
| |
Collapse
|
4
|
Pereira AR, Lipphaus A, Ergin M, Salehi S, Gehweiler D, Rudert M, Hansmann J, Herrmann M. Modeling of the Human Bone Environment: Mechanical Stimuli Guide Mesenchymal Stem Cell-Extracellular Matrix Interactions. Materials (Basel) 2021; 14:4431. [PMID: 34442954 PMCID: PMC8398413 DOI: 10.3390/ma14164431] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 08/02/2021] [Accepted: 08/03/2021] [Indexed: 02/06/2023]
Abstract
In bone tissue engineering, the design of in vitro models able to recreate both the chemical composition, the structural architecture, and the overall mechanical environment of the native tissue is still often neglected. In this study, we apply a bioreactor system where human bone-marrow hMSCs are seeded in human femoral head-derived decellularized bone scaffolds and subjected to dynamic culture, i.e., shear stress induced by continuous cell culture medium perfusion at 1.7 mL/min flow rate and compressive stress by 10% uniaxial load at 1 Hz for 1 h per day. In silico modeling revealed that continuous medium flow generates a mean shear stress of 8.5 mPa sensed by hMSCs seeded on 3D bone scaffolds. Experimentally, both dynamic conditions improved cell repopulation within the scaffold and boosted ECM production compared with static controls. Early response of hMSCs to mechanical stimuli comprises evident cell shape changes and stronger integrin-mediated adhesion to the matrix. Stress-induced Col6 and SPP1 gene expression suggests an early hMSC commitment towards osteogenic lineage independent of Runx2 signaling. This study provides a foundation for exploring the early effects of external mechanical stimuli on hMSC behavior in a biologically meaningful in vitro environment, opening new opportunities to study bone development, remodeling, and pathologies.
Collapse
Affiliation(s)
- Ana Rita Pereira
- IZKF Group Tissue Regeneration in Musculoskeletal Diseases, University Hospital Wuerzburg, 97070 Wuerzburg, Germany; (A.R.P.); (M.E.)
- Bernhard-Heine-Centrum for Locomotion Research, University of Wuerzburg, 97074 Wuerzburg, Germany
| | - Andreas Lipphaus
- Biomechanics Research Group, Ruhr-University Bochum, 44801 Bochum, Germany;
| | - Mert Ergin
- IZKF Group Tissue Regeneration in Musculoskeletal Diseases, University Hospital Wuerzburg, 97070 Wuerzburg, Germany; (A.R.P.); (M.E.)
- Department of Biomaterials, Center of Energy Technology und Materials Science (TAO), University of Bayreuth, 95447 Bayreuth, Germany;
| | - Sahar Salehi
- Department of Biomaterials, Center of Energy Technology und Materials Science (TAO), University of Bayreuth, 95447 Bayreuth, Germany;
| | | | - Maximilian Rudert
- Department of Orthopedic Surgery, Koenig-Ludwig-Haus, University of Wuerzburg, 97074 Wuerzburg, Germany;
| | - Jan Hansmann
- Fraunhofer Institute for Silicate Research, Translational Center for Regenerative Therapies, 97082 Wuerzburg, Germany;
| | - Marietta Herrmann
- IZKF Group Tissue Regeneration in Musculoskeletal Diseases, University Hospital Wuerzburg, 97070 Wuerzburg, Germany; (A.R.P.); (M.E.)
- Bernhard-Heine-Centrum for Locomotion Research, University of Wuerzburg, 97074 Wuerzburg, Germany
| |
Collapse
|
5
|
Itskovich Y, Meikle MC, Cannon RD, Farella M, Coates DE, Milne TJ. Differential behaviour and gene expression in 3D cultures of femoral- and calvarial-derived human osteoblasts under a cyclic compressive mechanical load. Eur J Oral Sci 2021; 129:e12818. [PMID: 34289176 DOI: 10.1111/eos.12818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Revised: 06/02/2021] [Accepted: 06/14/2021] [Indexed: 11/29/2022]
Abstract
The aim of the study was to compare the response of calvarial and femoral osteoblasts cultured in a 3D hydrogel environment to cyclic compressive mechanical loading. Human foetal femoral and calvarial osteoblasts were encapsulated in a semi-synthetic thiol-modified hyaluronan gelatin polyethylene glycol diacrylate (PEGDA) cross-linked HyStemC hydrogel. Constructs were subjected to a cyclic compressive strain of 33.4 kPa force every second for 5 s every hour for 6 h per day using FlexCell BioPress culture plates and compared to non-compressed constructs. Cell viability, mineralisation, and morphological changes were observed over 21 days. BMP2, ALP, COL1A1, COL2A1, and OCN gene expression levels were quantified. Encapsulated osteoblast numbers increased and formed hydroxyapatite over a 21-day period. Cell viability decreased under a cyclical strain when compared to cells under no strain. Femoral osteoblasts under strain expressed increased levels of BMP2 (53.9-fold) and COL1A1 (5.1-fold) mRNA compared to no strain constructs. Surprisingly, no BMP2 mRNA was detected in calvarial osteoblasts. Osteoblasts derived from endochondral (femoral) and intra-membranous (calvarial) processes behaved differently in 3D-constructs. We therefore recommend that site-specific osteoblasts be used for future bone engineering and bone replacement materials and further research undertaken to elucidate how site-specific osteoblasts respond to cyclic compressive loads.
Collapse
Affiliation(s)
- Yana Itskovich
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Murray C Meikle
- King's College Dental Institute, University of London, London, UK
| | - Richard D Cannon
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Mauro Farella
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Dawn E Coates
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Trudy J Milne
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| |
Collapse
|
6
|
Alsubaiy EF, Chaturvedi S, Qutub OA, Mously HA, Zarbah MA, Haralur SB, Bhagat TV. Novel CAD-CAM zirconia coping design to enhance the aesthetics and strength for anterior PLZ crowns. Technol Health Care 2021; 29:1161-1171. [PMID: 33998567 DOI: 10.3233/thc-202782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The aesthetics and strength of anterior porcelain layered zirconia (PLZ) crowns are mainly affected by the zirconia (Zr) coping design. There is a need for a modified design to enhance aesthetics with strength. OBJECTIVES The purpose of this study was to compare the fracture resistance of anterior PLZ crowns having modified CAD-CAM Zr coping designs (in terms of thickness and marginal collar designs) with standard Zr copings. METHODS Fifty PLZ crowns were fabricated and divided into two groups: Gr 1: Standard Zr Coping (SZC) (control gr) with 0.5 mm thickness (Facial-F, Mesial-M, Distal-D, incisal-I, and Palatal-P) without a collar; Gr 2: Collar Zr Coping (CZC) (test gr) with 2.5 mm collar height on M, D, P and 0.2 mm F and variable facial wall thickness. Subgroups: Gr 2a: (CZC-0.5 mm) facial wall thickness 0.5 mm; Gr 2b: (CZC-0.4 mm) facial wall thickness 0.4 mm; Gr 2c: (CZC-0.3 mm) facial wall thickness 0.3 mm; Gr 2d: (CZC-0.2 mm) facial wall thickness 0.2 mm. The fracture load was determined and analysed using One-way ANOVA and Dunnet test. RESULTS The minimum fracture load was 927.36 ± 127.80 N observed for Gr 2c (CZC at 0.3 mm) while the maximum fracture load was 1373.61 ± 146.54 N observed for Gr 2a (CZC at 0.5 mm). A highly significant difference in mean fracture load among various Zr coping groups (p< 0.001) was determined. CONCLUSIONS Novel Zr coping design for anterior PLZ crowns can provide better aesthetics with strength. Reducing the thickness of Zr coping in the aesthetic zone to 0.2 mm and providing a modified collar design (2.5 mm collar height on M, D, P, and 0.2 mm F) would provide strength without jeopardizing aesthetics.
Collapse
Affiliation(s)
- Ebrahim Fihaid Alsubaiy
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Saurabh Chaturvedi
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Osama A Qutub
- Oral and Maxillofacial Prosthodontics Department, College of Dentistry, King Abdulaziz University, Saudi Arabia
| | - Hisham Abdullah Mously
- Oral and Maxillofacial Prosthodontics Department, College of Dentistry, King Abdulaziz University, Saudi Arabia
| | - Mohammad Abdullah Zarbah
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Satheesh B Haralur
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Tushar V Bhagat
- College of Dentistry, Prince Sattam bin Abdulaziz University, AlKharj, Saudi Arabia
| |
Collapse
|
7
|
Cabeza M, Díaz B, Nóvoa XR, Pérez C, Pérez MC. The Effect of Loading on the Diffusivity of Chlorides in Mortar. Materials (Basel) 2019; 12:ma12162527. [PMID: 31398882 PMCID: PMC6718981 DOI: 10.3390/ma12162527] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 08/01/2019] [Accepted: 08/07/2019] [Indexed: 12/04/2022]
Abstract
This study focuses on the effect generated by a compressive load, in the range 15%–60% of the ultimate load (Fu), in the chloride penetration rate of cement-based materials. The modifications produced in the microstructure influence the transport properties, and, thus, the validation of several interesting parameters, such as, the load value and the loading time, including both static and dynamic loading modes, was evaluated. This analysis was performed by impedance spectroscopy (IS), a non-destructive technique that allowed, after the appropriate modeling analysis, the assessment of the resistivity of the sample, a parameter that has been correlated to the diffusion coefficient in a previous investigation. The experimental arrangement was designed to allow the recording of the impedance spectra under the effect of a compressive load and, thus, the real-time monitoring of the chloride diffusivity was provided. An increase in the diffusion coefficient was verified for a load at 60%Fu whereas no variations were obtained for the load fixed at 30%. A relevant difference could be checked if the values were measured once the load was removed, showing the importance of the precise loading stage for the chloride diffusion study.
Collapse
Affiliation(s)
- Marta Cabeza
- ENCOMAT group, University of Vigo, EEI, Campus Universitario, 36310 Vigo, Spain
| | - Belén Díaz
- ENCOMAT group, University of Vigo, EEI, Campus Universitario, 36310 Vigo, Spain.
| | - X Ramón Nóvoa
- ENCOMAT group, University of Vigo, EEI, Campus Universitario, 36310 Vigo, Spain
| | - Carmen Pérez
- ENCOMAT group, University of Vigo, EEI, Campus Universitario, 36310 Vigo, Spain
| | - M Consuelo Pérez
- ENCOMAT group, University of Vigo, EEI, Campus Universitario, 36310 Vigo, Spain
| |
Collapse
|
8
|
Buasiri T, Habermehl-Cwirzen K, Krzeminski L, Cwirzen A. Piezoresistive Load Sensing and Percolation Phenomena in Portland Cement Composite Modified with In-Situ Synthesized Carbon Nanofibers. Nanomaterials (Basel) 2019; 9:E594. [PMID: 30974888 PMCID: PMC6523284 DOI: 10.3390/nano9040594] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Revised: 03/29/2019] [Accepted: 04/03/2019] [Indexed: 11/17/2022]
Abstract
Carbon nanofibers (CNFs) were directly synthesized on Portland cement particles by chemical vapor deposition. The so-produced cements contained between 2.51-2.71 wt% of CNFs; depending on the production batch. Several mortar mixes containing between 0 and 10 wt% of the modified cement were produced and the electrical properties at various ages and the load sensing capabilities determined. The percolation threshold related to the electrical conductivity was detected and corresponded to the amount of the present CNFs, 0.271, 0.189, 0.135 and 0.108 wt%. The observed threshold depended on the degree of hydration of the Portland cement. The studied mortars showed a strong piezoresistive response to the applied compressive load reaching a 17% change of the electrical resistivity at an applied load of 3.5 MPa and 90% at 26 MPa. This initial study showed that the studied material is potentially suitable for future development of novel fully integrated monitoring systems for concrete structures.
Collapse
Affiliation(s)
- Thanyarat Buasiri
- Building Materials, Department of Civil, Environmental and Natural Resources Engineering, Luleå University of Technology, 97187 Luleå, Sweden.
| | - Karin Habermehl-Cwirzen
- Building Materials, Department of Civil, Environmental and Natural Resources Engineering, Luleå University of Technology, 97187 Luleå, Sweden.
| | - Lukasz Krzeminski
- The Institute of Engineering Materials and Biomaterials, Silesian University of Technology, 44-100 Gliwice, Poland.
| | - Andrzej Cwirzen
- Building Materials, Department of Civil, Environmental and Natural Resources Engineering, Luleå University of Technology, 97187 Luleå, Sweden.
| |
Collapse
|
9
|
Sharma V, Grujovic N, Zivic F, Slavkovic V. Influence of Porosity on the Mechanical Behavior during Uniaxial Compressive Testing on Voronoi-Based Open-Cell Aluminium Foam. Materials (Basel) 2019; 12:E1041. [PMID: 30934831 DOI: 10.3390/ma12071041] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Revised: 03/18/2019] [Accepted: 03/25/2019] [Indexed: 11/17/2022]
Abstract
We have studied an application of the Voronoi tessellation method in the modeling of open-cell aluminium foam under uniaxial compressive loading. The Voronoi code was merged with computer-aided design (CAD) for converting the polyhedral model into an irregular open-cell cellular structure to create porous samples for compression testing simulations. Numerical simulations of the uniaxial compression uniformly over the upper surface of the sample in the z-axis direction at a constant 20 N load was realised. Samples with three different porosities (30%, 60% and 80%) were studied. A nonlinear elasto-plastic material model with perfect plasticity, without hardening, based on the von Mises yield criterion was applied below 10% strain. Corresponding stress–strain curves were observed and the influence of porosity on deformation mechanism was discussed. Samples with higher porosity exhibited significantly higher normal stress under the same load, and increased stress plateaus. An increase of porosity produced an increase of both compressive and tensile stresses and struts exhibited complex stress fields. Voronoi-based modeling was in accordance with experimental results in the literature in the case of the quasi-static condition and linear elastic region (below 1% strain). Further study is necessary to enable the simulation of real dynamic behaviour under all deformation regimes by using the Voronoi tessellation method.
Collapse
|
10
|
Sintini I, Fitzpatrick CK, Clary CW, Castelli VP, Rullkoetter PJ. Computational evaluation of TKR stability using feedback-controlled compressive loading. J Orthop Res 2018; 36:1901-1909. [PMID: 29393547 DOI: 10.1002/jor.23862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2017] [Accepted: 01/08/2018] [Indexed: 02/04/2023]
Abstract
Pre-clinical assessment of stability in total knee replacement is crucial for developing preferred implant performance. Current total knee replacement patients often experience joint instability that the human body addresses with compensatory strategies. Specifically, an increased quadriceps-hamstrings co-contraction serves to increase joint stability through an increased compressive force across the tibiofemoral joint. The aim of this study is to introduce a novel method to evaluate total knee replacement by determining the compressive loading required to achieve natural knee stability. Four current total knee replacement geometries in both their cruciate-retaining and posterior-stabilized forms are modeled in a finite-element framework. The finite-element model is initially validated experimentally using traditional knee laxity testing with a constant compressive load and anterior-posterior displacement or internal-external rotation. Model predictions of constraint are in reasonable agreement with experimental results (average root mean square errors: 0.46 Nm, 62.5 N). The finite-element model is subsequently interfaced with a feedback controller to vary the compressive force that the implant requires in order to match experimental natural knee internal-external and anterior-posterior stability at different flexion angles. Results show that the lower constraint total knee replacement designs require on average 66.7% more compressive load than the higher constraint designs to achieve natural knee constraint. As expected, total knee replacement stability and compressive load requirements to replicate natural kinematics vary with inclusion of tibiofemoral ligaments. The current study represents a novel approach to evaluate stability in existing total knee replacement geometries and to design implants that better restore natural knee mechanics. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1901-1909, 2018.
Collapse
Affiliation(s)
- Irene Sintini
- Center for Orthopaedics Biomechanics, University of Denver, Denver, Colorado.,Department of Industrial Engineering, University of Bologna, Bologna, Italy
| | - Clare K Fitzpatrick
- Center for Orthopaedics Biomechanics, University of Denver, Denver, Colorado
| | - Chadd W Clary
- Center for Orthopaedics Biomechanics, University of Denver, Denver, Colorado.,DePuy Synthes, Inc., Warsaw, Indiana
| | | | - Paul J Rullkoetter
- Center for Orthopaedics Biomechanics, University of Denver, Denver, Colorado
| |
Collapse
|
11
|
Tseng SC, Shields RK. Limb Segment Load Inhibits the Recovery of Soleus H-Reflex After Segmental Vibration in Humans. J Mot Behav 2017; 50:631-642. [PMID: 29140761 DOI: 10.1080/00222895.2017.1394259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
We investigated the effects of vertical vibration and compressive load on soleus H-reflex amplitude and postactivation depression. We hypothesized that, in the presence of a compressive load, limb vibration induces a longer suppression of soleus H-reflex. Eleven healthy adults received vibratory stimulation at a fixed frequency (30 Hz) over two loading conditions (0% and 50% of individual's body weight). H-reflex amplitude was depressed ∼88% in both conditions during vibration. Cyclic application of compression after cessation of the vibration caused a persistent reduction in H-reflex excitability and postactivation depression for > 2.5 min. A combination of limb segment vibration and compression may offer a nonpharmacologic method to modulate spinal reflex excitability in people after CNS injury.
Collapse
Affiliation(s)
- Shih-Chiao Tseng
- a School of Physical Therapy , Texas Woman's University , 6700 Fannin, Houston , Texas , USA
| | - Richard K Shields
- b Department of Physical Therapy & Rehabilitation Science , University of Iowa, Carver College of Medicine , Iowa City , Iowa , USA
| |
Collapse
|
12
|
Abstract
STUDY DESIGN Longitudinal repeated-measures; within-subject control. OBJECTIVE We examined the extent to which an isometric plantar flexion training protocol attenuates bone loss longitudinally after SCI. SUMMARY OF BACKGROUND DATA After spinal cord injury (SCI), bone mineral density (BMD) of paralyzed extremities rapidly declines, likely because of loss of mechanical loading of bone via muscle contractions. METHODS Six individuals with complete paralysis began a 3-year unilateral plantar flexor muscle activation program within 4.5 months after SCI. The opposite limb served as a control. Compliance with recommended dose was > 80%. Tibia compressive force was > 140% of body weight. RESULTS Bilateral hip and untrained tibia BMD declined significantly over the course of the training. Lumbar spine BMD showed minimal change. Percent decline in BMD (from the baseline condition) for the trained tibia (approximately 10%) was significantly less than the untrained tibia (approximately 25%) (P < 0.05). Trained limb percent decline in BMD remained steady over the first 1.5 years of the study (P < 0.05). CONCLUSIONS Compressive loads of approximately 1 to 2 times body weight, induced by muscle contractions, partially prevent the loss of BMD after SCI. Future studies should establish dose-response curves for attenuation of bone loss after SCI.
Collapse
Affiliation(s)
- Richard K Shields
- Graduate Program in Physical Therapy and Rehabilitation Science, University of Iowa, Iowa City, IA 52242-1190, USA.
| | | | | |
Collapse
|