1
|
Corrigendum: New Breakthroughs and Innovation Modes in English Education in Post-pandemic Era. Front Psychol 2022; 13:899201. [PMID: 35496248 PMCID: PMC9041302 DOI: 10.3389/fpsyg.2022.899201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 03/21/2022] [Indexed: 11/13/2022] Open
Abstract
[This corrects the article DOI: 10.3389/fpsyg.2022.839440.].
Collapse
|
2
|
New Breakthroughs and Innovation Modes in English Education in Post-pandemic Era. Front Psychol 2022; 13:839440. [PMID: 35222216 PMCID: PMC8873145 DOI: 10.3389/fpsyg.2022.839440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Accepted: 01/10/2022] [Indexed: 11/29/2022] Open
Abstract
The outbreak of COVID-19 has brought drastic changes to English teaching as it has shifted from the offline mode before the pandemic to the online mode during the pandemic. However, in the post-pandemic era, there are still many problems in the effective implementation of the process of English teaching, leading to the inability of achieving better results in the quality and efficiency of English teaching and effective cultivation of students' practical application ability. In recent years, English speaking has attracted the attention of experts and scholars. Therefore, this study constructs an interactive English-speaking practice scene based on a virtual character. A dual-modality emotion recognition method is proposed that mainly recognizes and analyzes facial expressions and physiological signals of students and the virtual character in each scene. Thereafter, the system adjusts the difficulty of the conversation according to the current state of students, toward making the conversation more conducive to the students' understanding and gradually improving their English-speaking ability. The simulation compares nine facial expressions based on the eNTERFACE05 and CAS-PEAL datasets, which shows that the emotion recognition method proposed in this manuscript can effectively recognize students' emotions in interactive English-speaking practice and reduce the recognition time to a great extent. The recognition accuracy of the nine facial expressions was close to 90% for the dual-modality emotion recognition method in the eNTERFACE05 dataset, and the recognition accuracy of the dual-modality emotion recognition method was significantly improved with an average improvement of approximately 5%.
Collapse
|
3
|
Effective Diagnosis of Foot-And-Mouth Disease Virus (FMDV) Serotypes O and A Based on Optical and Electrochemical Dual-Modal Detection. Biomolecules 2021; 11:biom11060841. [PMID: 34198783 PMCID: PMC8229964 DOI: 10.3390/biom11060841] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 05/31/2021] [Accepted: 06/01/2021] [Indexed: 12/31/2022] Open
Abstract
Foot-and-mouth disease virus (FMDV) is a highly contagious disease that affects cloven-hoofed animals. The traditional diagnostic methods for FMDV have several drawbacks such as cross-reactivity, low sensitivity, and low selectivity. To overcome these drawbacks, we present an optical and electrochemical dual-modal approach for the specific detection of FMDV serotypes O and A by utilizing a magnetic nanoparticle labeling technique with resorufin β-d-glucopyranoside (res-β-glc) and β-glucosidase (β-glc), without the use of typical lateral flow assay or polymerase chain reaction. FMDV serotypes O and A were reacted with pan-FMDV antibodies that recognize all seven FMDV serotypes (O, A, C, Asia 1, SAT 1, SAT 2, and SAT 3). The antigen–antibody complex was then immobilized on magnetic nanoparticles and reacted with β-glc-conjugated FMDV type O or type A antibodies. Subsequently, the addition of res-β-glc resulted in the release of fluorescent resorufin and glucose owing to catalytic hydrolysis by β-glc. The detection limit of fluorescent signals using a fluorescence spectrophotometer was estimated to be log(6.7) and log(5.9) copies/mL for FMDV type O and A, respectively, while that of electrochemical signals using a glucometer was estimated to be log(6.9) and log(6.1) copies/mL for FMDV type O and A, respectively. Compared with a commercially available lateral flow assay diagnostic kit for immunochromatographic detection of FMDV type O and A, this dual-modal detection platform offers approximately four-fold greater sensitivity. This highly sensitive and accurate dual-modal detection method can be used for effective disease diagnosis and treatment, and will find application in the early-stage diagnosis of viral diseases and next-generation diagnostic platforms.
Collapse
|
4
|
Mobile-based oral cancer classification for point-of-care screening. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210101R. [PMID: 34164967 PMCID: PMC8220969 DOI: 10.1117/1.jbo.26.6.065003] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Accepted: 06/08/2021] [Indexed: 06/10/2023]
Abstract
SIGNIFICANCE Oral cancer is among the most common cancers globally, especially in low- and middle-income countries. Early detection is the most effective way to reduce the mortality rate. Deep learning-based cancer image classification models usually need to be hosted on a computing server. However, internet connection is unreliable for screening in low-resource settings. AIM To develop a mobile-based dual-mode image classification method and customized Android application for point-of-care oral cancer detection. APPROACH The dataset used in our study was captured among 5025 patients with our customized dual-modality mobile oral screening devices. We trained an efficient network MobileNet with focal loss and converted the model into TensorFlow Lite format. The finalized lite format model is ∼16.3 MB and ideal for smartphone platform operation. We have developed an Android smartphone application in an easy-to-use format that implements the mobile-based dual-modality image classification approach to distinguish oral potentially malignant and malignant images from normal/benign images. RESULTS We investigated the accuracy and running speed on a cost-effective smartphone computing platform. It takes ∼300 ms to process one image pair with the Moto G5 Android smartphone. We tested the proposed method on a standalone dataset and achieved 81% accuracy for distinguishing normal/benign lesions from clinically suspicious lesions, using a gold standard of clinical impression based on the review of images by oral specialists. CONCLUSIONS Our study demonstrates the effectiveness of a mobile-based approach for oral cancer screening in low-resource settings.
Collapse
|
5
|
Fiber-based photoacoustic remote sensing microscopy and spectral-domain optical coherence tomography with a dual-function 1050-nm interrogation source. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210075R. [PMID: 34164968 PMCID: PMC8220968 DOI: 10.1117/1.jbo.26.6.066502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2021] [Accepted: 05/27/2021] [Indexed: 05/08/2023]
Abstract
SIGNIFICANCE Spectral-domain optical coherence tomography (SD-OCT) offers depth-resolved imaging of optical scattering contrast but is limited in sensitivity to optical absorption. Dual-modality imaging combined with the noncontact absorption contrast of photoacoustic remote sensing (PARS) microscopy can augment SD-OCT applications with specific molecular and functional contrasts in an all-optical, fiber-based platform. AIM To develop a fiber-based multimodal PARS and SD-OCT imaging system, which efficiently uses a common 1050-nm light source for SD-OCT and PARS interrogation. APPROACH PARS microscopy has predominantly utilized a 1310-nm interrogation light source to date. Hence, a recent dual-modality PARS and 1050-nm SD-OCT imaging system required three distinct wavelengths including a 532-nm PARS excitation, necessitating a free-space optical architecture with discrete subsystems. Here, we validate the first use of a 1050-nm interrogation wavelength for PARS. This enables the transition to fiber-based interferometry as is standard in modern SD-OCT systems, though infeasible with inclusion of an additional 1310-nm wavelength. PARS interrogation functionality is integrated using a broadband optical circulator. RESULTS Dual-modality imaging is demonstrated in carbon fiber phantoms and a mouse ear in vivo. SD-OCT provided a 4.5-μm lateral resolution, 8.8-μm axial resolution in air, and >101 dB of sensitivity, and PARS contributed 532-nm optical absorption contrast with a 47-dB SNR, and lateral and axial resolutions of 2.4 and 35 μm, respectively. Total interrogation power was reduced from 90% to 58% of the ANSI limit compared to a previous three-wavelength approach. CONCLUSIONS Adapting PARS to use the 1050-nm SD-OCT light source for interrogation enabled implementation of a fiber-based dual-modality system configuration, with image quality maintained. This will facilitate development of potential applications demanding handheld, catheter-based, or endoscopic form factors.
Collapse
|
6
|
Boys-Specific Text-Comprehension Enhancement With Dual Visual-Auditory Text Presentation Among 12-14 Years-Old Students. Front Psychol 2021; 12:574685. [PMID: 33897513 PMCID: PMC8062718 DOI: 10.3389/fpsyg.2021.574685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2020] [Accepted: 03/12/2021] [Indexed: 11/13/2022] Open
Abstract
Quality of language comprehension determines performance in all kinds of activities including academics. Processing of words initially develops as auditory, and gradually extends to visual as children learn to read. School failure is highly related to listening and reading comprehension problems. In this study we analyzed sex-differences in comprehension of texts in Spanish (standardized reading test PROLEC-R) in three modalities (visual, auditory, and both simultaneously: dual-modality) presented to 12-14-years old students, native in Spanish. We controlled relevant cognitive variables such as attention (d2), phonological and semantic fluency (FAS) and speed of processing (WISC subtest Coding). Girls' comprehension was similar in the three modalities of presentation, however boys were importantly benefited by dual-modality as compared to boys exposed only to visual or auditory text presentation. With respect to the relation of text comprehension and school performance, students with low grades in Spanish showed low auditory comprehension. Interestingly, visual and dual modalities preserved comprehension levels in these low skilled students. Our results suggest that the use of visual-text support during auditory language presentation could be beneficial for low school performance students, especially boys, and encourage future research to evaluate the implementation in classes of the rapidly developing technology of simultaneous speech transcription, that could be, in addition, beneficial to non-native students, especially those recently incorporated into school or newly arrived in a country from abroad.
Collapse
|
7
|
Polydopamine-modified dual-ligand nanoparticles as highly effective and targeted magnetic resonance/photoacoustic dual-modality thrombus imaging agents. Int J Nanomedicine 2019; 14:7155-7171. [PMID: 31564871 PMCID: PMC6731970 DOI: 10.2147/ijn.s216603] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Accepted: 08/01/2019] [Indexed: 12/29/2022] Open
Abstract
Background Platelet activation and subsequent aggregation are the initial stages of thrombosis. A molecular probe that specifically targets activated platelets and remains retained under high shear stress in vivo can enhance the imaging effect to achieve early and accurate diagnosis. Methods and materials In this study, we constructed nanoparticles (NPs) using polydopamine to carry two peptides that simultaneously bind integrin αIIbβ3 and P-selectin on activated platelets to enhance the targeting of NPs to thrombus. Results The targeting specificity and binding stability of the NPs on red and white thrombi were demonstrated in vitro using a simulated circulatory device and the targeting effect of the NPs on mixed thrombus was studied by magnetic resonance (MR)/photoacoustic (PA) dual-modality imaging in vivo. NPs that were surface modified with both peptides have higher selectivity and retention to red and white thrombi in vitro than NPs with a single or no peptide, and the targeting effect was closely related to the number and distribution of activated platelets as well as the structure and type of thrombus. The NPs also have MR/PA dual-modality imaging functionality, significantly enhancing the imaging of mixed thrombus in vivo. Conclusion These dual-targeted NPs have improved targeting specificity and binding stability to different thrombi under high shear stress and are beneficial for the early diagnosis of thrombosis.
Collapse
|
8
|
Fabrication and Application of Dual-Modality Polymer Nanoparticles Based on an Aggregation-Induced Emission-Active Fluorescent Molecule and Magnetic Fe₃O₄. Polymers (Basel) 2019; 11:polym11020220. [PMID: 30960204 PMCID: PMC6419270 DOI: 10.3390/polym11020220] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Revised: 01/23/2019] [Accepted: 01/24/2019] [Indexed: 12/22/2022] Open
Abstract
Fluorescent magnetic nanoparticles (NPs) utilized for imaging hold great promise for biomedical applications, but it remains a challenging task. Here, we report novel dual-modality NPs using an aggregation-induced emission (AIE)-active and near-infrared (NIR) emissive dye (TPAS) and magnetic Fe3O4 as the core, and biocompatible polymer Pluronic F-127 as the encapsulation matrix by self-assembly procedures. The obtained fluorescent-magnetic AIE NPs have both high fluorescence quantum yield (13.8%) at 700 nm and high magnetic saturation value. With good photostability and biocompatibility, the resulting NPs show effective MRI ability, but also a stain in cytoplasm with a strong NIR fluorescent signal.
Collapse
|
9
|
Three-Dimensional Tumor Margin Demarcation Using the Hybrid Tracer Indocyanine Green- 99mTc-Nanocolloid: A Proof-of-Concept Study in Tongue Cancer Patients Scheduled for Sentinel Node Biopsy. J Nucl Med 2018; 60:764-769. [PMID: 30504140 DOI: 10.2967/jnumed.118.220202] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Accepted: 10/26/2018] [Indexed: 12/15/2022] Open
Abstract
For radical resection of squamous cell carcinoma of the oral cavity, a tumor-free margin of at least 5 mm is required. Unfortunately, establishing in-depth margins is a surgical conundrum. Knowing that the hybrid sentinel node (SN) tracer indocyanine green (ICG)-99mTc-nanocolloid generates temporary tattoolike markings at the site of administration, we studied the ability to apply this tracer for tumor margin demarcation combined with SN biopsy. Methods: Nineteen patients with clinical T1-T2 oral tongue tumors received the traditional superficial 3 or 4 deposits of ICG-99mTc-nanocolloid (0.1 mL each), and in 12 patients additional deposits were placed deeply using ultrasound guidance (total of 6; 0.07 mL each). SN mapping was performed using lymphoscintigraphy and SPECT/CT. Before and directly after tumor excision, fluorescence imaging was performed to monitor the tracer deposits in the patient (fluorescent deposits were not used to guide the surgical excision). At pathologic examination, primary tumor samples were studied in detail. Results: The number of tracer depositions did not induce a significant difference in the number of SNs visualized (P = 0.836). Reproducible and deep tracer deposition proved to be challenging. The fluorescent nature of ICG-99mTc-nanocolloid supported in vivo and ex vivo identification of the tracer deposits surrounding the tumor. Pathologic examination indicated that in 66.7% (8/12), all fluorescence was observed within the resection margins. Conclusion: This study indicates that tumor margin demarcation combined with SN identification has potential but that some practical challenges need to be overcome if this technique is to mature as a surgical guidance concept. Future studies need to define whether the technology can improve the radical nature of the resections.
Collapse
|
10
|
Ultrasensitive Virion Immunoassay Platform with Dual-Modality Based on a Multifunctional Aggregation-Induced Emission Luminogen. ACS NANO 2018; 12:9549-9557. [PMID: 30148962 DOI: 10.1021/acsnano.8b05270] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Sensitive and accurate detection of highly contagious virus is urgently demanded for disease diagnosis and treatment. Herein, based on a multifunctional aggregation-induced emission luminogen (AIEgen), a dual-modality readout immunoassay platform for ultrasensitive detection of viruses has been successfully demonstrated. The platform is relied on virions immuno-bridged enzymatic hydrolysis of AIEgen, accompanying with the in situ formation of highly emissive AIE aggregates and shelling of silver on gold nanoparticles. As a result, robust turn-on fluorescence and naked-eye discernible plasmonic colorimetry composed dual-signal is achieved. By further taking advantage of effective immunomagnetic enrichment, EV71 virions, as an example, can be specifically detected with a limit of detection down to 1.4 copies/μL under fluorescence modality. Additionally, semiquantitative discerning of EV71 virions is realized in a broad range from 1.3 × 103 to 2.5 × 106 copies/μL with the naked eye. Most importantly, EV71 virions in 24 real clinical samples are successfully diagnosed with 100% accuracy. Comparing to the gold standard polymerase chain reaction (PCR) assay, our immunoassay platform do not need complicated sample pretreatment and expensive instruments. This dual-modality strategy builds a good capability for both colorimetry based convenient preliminary screening and fluorescence based accurate diagnosis of suspect infections in virus-stricken areas.
Collapse
|
11
|
Progress and Trends in AIE-Based Bioprobes: A Brief Overview. ACS APPLIED MATERIALS & INTERFACES 2018; 10:12217-12261. [PMID: 29140079 DOI: 10.1021/acsami.7b14343] [Citation(s) in RCA: 208] [Impact Index Per Article: 34.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Luminescent bioprobes are powerful analytical means for biosensing and optical imaging. Luminogens featured with aggregation-induced emission (AIE) attributes have emerged as ideal building blocks for high-performance bioprobes. Bioprobes constructed with AIE luminogens have been identified to be a novel class of FL light-up probing tools. In contrast to conventional bioprobes based on the luminophores with aggregation-caused quenching (ACQ) effect, the AIE-based bioprobes enjoy diverse superiorities, such as lower background, higher signal-to-noise ratio and sensitivity, better accuracy, and more outstanding resistance to photobleaching. AIE-based bioprobes have been tailored for a vast variety of purposes ranging from biospecies sensing to bioimaging to theranostics (i.e., image-guided therapies). In this review, recent five years' advances in AIE-based bioprobes are briefly overviewed in a perspective distinct from other reviews, focusing on the most appealing trends and progresses in this flourishing research field. There are altogether 11 trends outlined, which have been classified into four aspects: the probe composition and form (bioconjugtes, nanoprobes), the output signal of probe (far-red/near-infrared luminescence, two/three-photon excited fluorescence, phosphorescence), the modality and functionality of probing system (dual-modality, dual/multifunctionality), the probing object and application outlet (specific organelles, cancer cells, bacteria, real samples). Typical examples of each trend are presented and specifically demonstrated. Some important prospects and challenges are pointed out as well in the hope of intriguing more interests from researchers working in diverse areas into this exciting research field.
Collapse
|
12
|
Theranostic imaging of liver cancer using targeted optical/MRI dual-modal probes. Oncotarget 2018; 8:32741-32751. [PMID: 28416757 PMCID: PMC5464824 DOI: 10.18632/oncotarget.15642] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2016] [Accepted: 12/05/2016] [Indexed: 12/15/2022] Open
Abstract
The accurate preoperative detection and intraoperative navigation afforded by imaging techniques have had significant impact on the success of liver cancer surgeries. However, it is difficult to achieve satisfactory performance in both diagnosis and surgical treatment processes using any single modality imaging method. Here, we report the synthesis and characteristics of a novel dual-modality magnetic resonance imaging (MRI) and near-infrared fluorescence (NIRF) probe and verify its feasibility in nude mouse models with liver cancer. The probes are comprised of superparamagnetic iron oxide (SPIO) nanoparticles coated with liposomes to which a tumor-targeted agent, Arg-Gly-Asp peptides (RGD), and a NIRF dye (indocyanine green, ICG) have been conjugated. Specific targeting, biodistribution, and the imaging ability of the probes for MRI-NIRF were examined. Furthermore, we applied the dual-modality methodology toward the preoperative diagnosis and intraoperative guidance of radical resection in mouse models with both orthotopic liver tumors and intrahepatic tumor metastasis. The study demonstrated that both MRI and fluorescent images showed clear tumor delineation after probe injection (SPIO@Liposome-ICG-RGD). The contrast-to-noise ratio obtained from MRI was 31.9 ± 25.4 at post-injection for the preoperative diagnosis, which is helpful for detecting small tumors (0.9 ± 0.5 mm). The maximum tumor to background ratio of NIRF imaging was 2.5 ± 0.3 at 72 h post-injection for effectively capturing miniscule tumor lesions (0.6 ± 0.3 mm) intraoperatively. The novel MRI-NIRF dual modality probes are promising for the achievement of more accurate liver tumor detection and resection.
Collapse
|
13
|
Abstract
A current controversy in the area of implicit statistical learning (ISL) is whether this process consists of a single, central mechanism or multiple modality-specific ones. To provide insight into this question, the current study involved three ISL experiments to explore whether multimodal input sources are processed separately in each modality or are integrated together across modalities. In Experiment 1, visual and auditory ISL were measured under unimodal conditions, with the results providing a baseline level of learning for subsequent experiments. Visual and auditory sequences were presented separately, and the underlying grammar used for both modalities was the same. In Experiment 2, visual and auditory sequences were presented simultaneously with each modality using the same artificial grammar to investigate whether redundant multisensory information would result in a facilitative effect (i.e., increased learning) compared to the baseline. In Experiment 3, visual and auditory sequences were again presented simultaneously but this time with each modality employing different artificial grammars to investigate whether an interference effect (i.e., decreased learning) would be observed compared to the baseline. Results showed that there was neither a facilitative learning effect in Experiment 2 nor an interference effect in Experiment 3. These findings suggest that participants were able to track simultaneously and independently two sets of sequential regularities under dual-modality conditions. These findings are consistent with the theories that posit the existence of multiple, modality-specific ISL mechanisms rather than a single central one.
Collapse
|
14
|
Tracers for Fluorescence-Guided Surgery: How Elongation of the Polymethine Chain in Cyanine Dyes Alters the Pharmacokinetics of a Dual-Modality c[RGDyK] Tracer. J Nucl Med 2018; 59:986-992. [PMID: 29449447 DOI: 10.2967/jnumed.117.205575] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Accepted: 01/12/2018] [Indexed: 01/07/2023] Open
Abstract
The potential of receptor-mediated fluorescence-based image-guided surgery tracers is generally linked to the near-infrared emission profile and good-manufacturing-production availability of fluorescent dyes. Surprisingly, little is known about the critical interaction between the structural composition of the dyes and the pharmacokinetics of the tracers. In this study, a dual-modality tracer design was used to systematically and quantitatively evaluate the influence of elongation of the polymethine chain in a fluorescent cyanine dye on the imaging potential of a targeted tracer. Methods: As a model system, the integrin marker αvβ3 was targeted using arginylglycylaspartisc acid [RGD]-based vectors functionalized with a 111In-diethylenetriaminepentaacetic acid (DTPA) chelate and a fluorescent dye: (Cy3-(SO3)methyl-COOH [emission wavelength (λem), 580 nm], Cy5-(SO3)methyl-COOH [λem, 680 nm], or Cy7-(SO3)methyl-COOH [λem, 780 nm]). Tracers were analyzed for differences in photophysical properties, serum protein binding, chemical or optical stability, and signal penetration through tissue. Receptor affinities were evaluated using saturation and competition experiments. In vivo biodistribution (SPECT imaging and percentage injected dose per gram of tissue) was assessed in tumor-bearing mice and complemented with in vivo and ex vivo fluorescence images obtained using a clinical-grade multispectral fluorescence laparoscope. Results: Two carbon-atom-step variations in the polymethine chain of the fluorescent cyanine dyes were shown to significantly influence the chemical and photophysical characteristics (e.g., stability, brightness, and tissue penetration) of the hybrid RGD tracers. DTPA-Cy5-(SO3)methyl-COOH-c[RGDyK] structurally outperformed its Cy3 and Cy7 derivatives. Radioactivity-based evaluation of in vivo tracer pharmacokinetics yielded the lowest nonspecific uptake and highest tumor-to-background ratio for DTPA-Cy5-(SO3)methyl-COOH-c[RGDyK] (13.2 ± 1.7), with the Cy3 and Cy7 analogs trailing at respective tumor-to-background ratios of 5.7 ± 0.7 and 4.7 ± 0.7. Fluorescence-based assessment of tumor visibility revealed a similar trend. Conclusion: These findings underline that variations in the polymethine chain lengths of cyanine dyes have a profound influence on the photophysical properties, stability, and in vivo targeting capabilities of fluorescent imaging tracers. In a direct comparison, the intermediate-length dye (Cy5) yielded a superior c[RGDyK] tracer, compared with the shorter (Cy3) and longer (Cy7) analogs.
Collapse
|
15
|
Multifunctional PHPMA-Derived Polymer for Ratiometric pH Sensing, Fluorescence Imaging, and Magnetic Resonance Imaging. ACS APPLIED MATERIALS & INTERFACES 2018; 10:1556-1565. [PMID: 29210559 DOI: 10.1021/acsami.7b15796] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In this paper, we report synthesis and characterization of a novel multimodality (MRI/fluorescence) probe for pH sensing and imaging. A multifunctional polymer was derived from poly(N-(2-hydroxypropyl)methacrylamide) (PHPMA) and integrated with a naphthalimide-based-ratiometric fluorescence probe and a gadolinium-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid complex (Gd-DOTA complex). The polymer was characterized using UV-vis absorption spectrophotometry, fluorescence spectrofluorophotometry, magnetic resonance imaging (MRI), and confocal microscopy for optical and MRI-based pH sensing and cellular imaging. In vitro labeling of macrophage J774 and esophageal CP-A cell lines shows the polymer's ability to be internalized in the cells. The transverse relaxation time (T2) of the polymer was observed to be pH-dependent, whereas the spin-lattice relaxation time (T1) was not. The pH probe in the polymer shows a strong fluorescence-based ratiometric pH response with emission window changes, exhibiting blue emission under acidic conditions and green emission under basic conditions, respectively. This study provides new materials with multimodalities for pH sensing and imaging.
Collapse
|
16
|
In Vivo Dual-Modality Fluorescence and Magnetic Resonance Imaging-Guided Lymph Node Mapping with Good Biocompatibility Manganese Oxide Nanoparticles. Molecules 2017; 22:molecules22122208. [PMID: 29231865 PMCID: PMC6149721 DOI: 10.3390/molecules22122208] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2017] [Revised: 12/08/2017] [Accepted: 12/10/2017] [Indexed: 01/19/2023] Open
Abstract
Multifunctional manganese oxide nanoparticles (NPs) with impressive enhanced T₁ contrast ability show great promise in biomedical diagnosis. Herein, we developed a dual-modality imaging agent system based on polyethylene glycol (PEG)-coated manganese oxide NPs conjugated with organic dye (Cy7.5), which functions as a fluorescence imaging (FI) agent as well as a magnetic resonance imaging (MRI) imaging agent. The formed Mn₃O₄@PEG-Cy7.5 NPs with the size of ~10 nm exhibit good colloidal stability in different physiological media. Serial FI and MRI studies that non-invasively assessed the bio-distribution pattern and the feasibility for in vivo dual-modality imaging-guided lymph node mapping have been investigated. In addition, histological and biochemical analyses exhibited low toxicity even at a dose of 20 mg/kg in vivo. Since Mn₃O₄@PEG-Cy7.5 NPs exhibited desirable properties as imaging agents and good biocompatibility, this work offers a robust, safe, and accurate diagnostic platform based on manganese oxide NPs for tumor metastasis diagnosis.
Collapse
|
17
|
Synthesis and Evaluation of 64Cu-DOTA-NT-Cy5.5 as a Dual-Modality PET/Fluorescence Probe to Image Neurotensin Receptor-Positive Tumor. Mol Pharm 2015; 12:3054-61. [PMID: 26162008 DOI: 10.1021/acs.molpharmaceut.5b00325] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Overexpression of neurotensin receptors (NTRs) has been suggested to play important roles in the growth and survival of a variety of tumor types. The aim of this study is to develop a dual-modality probe (64Cu -DOTA-NT-Cy5.5) for imaging NTR1 expression in vivo with both positron emission tomography (PET) and fluorescence. In this approach, the thiol group and N terminal amino group of neurotensin analogue (Cys-NT) were chemically modified with Cy5.5 dye and DOTA chelator, respectively. After radiolabeling with 64Cu, the resulting probe (64Cu-DOTA-NT-Cy5.5) was evaluated in NTR1 positive HT-29 tumor model. Small animal PET quantification analysis demonstrated that the tumor uptake was 1.91±0.22 and 1.79±0.16%ID/g at 1 and 4 h postinjection (p.i.), respectively. The tumor-to-muscle ratio was 17.44±3.25 at 4 h p.i. based on biodistribution. Receptor specificity was confirmed by the successful blocking experiment at 4 h p.i. (0.42±0.05%ID/g). In parallel with PET experiment, fluorescence imaging was also performed, which demonstrated prominent tumor uptake in HT-29 model. As a proof of concept, an imaging guided surgery was performed to the fluorescent moiety of this probe and could provide potential surgery guidance for NTR positive patients. In summary, our results clearly indicated that the dual-modality probe, 64Cu-DOTA-NT-Cy5.5, could serve as a promising agent to image NTR positive tumors in vivo.
Collapse
|
18
|
In vivo molecular imaging of colorectal cancer using quantum dots targeted to vascular endothelial growth factor receptor 2 and optical coherence tomography/laser-induced fluorescence dual-modality imaging. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:096015. [PMID: 26397238 PMCID: PMC4963467 DOI: 10.1117/1.jbo.20.9.096015] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2015] [Accepted: 08/17/2015] [Indexed: 05/27/2023]
Abstract
Optical coherence tomography/laser induced fluorescence (OCT/LIF) dual-modality imaging allows for minimally invasive, nondestructive endoscopic visualization of colorectal cancer in mice. This technology enables simultaneous longitudinal tracking of morphological (OCT) and biochemical (fluorescence) changes as colorectal cancer develops, compared to current methods of colorectal cancer screening in humans that rely on morphological changes alone. We have shown that QDot655 targeted to vascular endothelial growth factor receptor 2 (QD655-VEGFR2) can be applied to the colon of carcinogen-treated mice and provides significantly increased contrast between the diseased and undiseased tissue with high sensitivity and specificity ex vivo. QD655-VEGFR2 was used in a longitudinal in vivo study to investigate the ability to correlate fluorescence signal to tumor development. QD655-VEGFR2 was applied to the colon of azoxymethane (AOM-) or saline-treated control mice in vivo via lavage. OCT/LIF images of the distal colon were taken at five consecutive time points every three weeks after the final AOM injection. Difficulties in fully flushing unbound contrast agent from the colon led to variable background signal; however, a spatial correlation was found between tumors identified in OCT images, and high fluorescence intensity of the QD655 signal, demonstrating the ability to detect VEGFR2 expressing tumors in vivo.
Collapse
|
19
|
In vivo tomographic imaging with fluorescence and MRI using tumor-targeted dual-labeled nanoparticles. Int J Nanomedicine 2013; 9:33-41. [PMID: 24368885 PMCID: PMC3869830 DOI: 10.2147/ijn.s52492] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Dual-modality imaging combines the complementary advantages of different modalities, and offers the prospect of improved preclinical research. The combination of fluorescence imaging and magnetic resonance imaging (MRI) provides cross-validated information and direct comparison between these modalities. Here, we report on the application of a novel tumor-targeted, dual-labeled nanoparticle (NP), utilizing iron oxide as the MRI contrast agent and near infrared (NIR) dye Cy5.5 as the fluorescent agent. Results of in vitro experiments verified the specificity of the NP to tumor cells. In vivo tumor targeting and uptake of the NPs in a mouse model were visualized by fluorescence and MR imaging collected at different time points. Quantitative analysis was carried out to evaluate the efficacy of MRI contrast enhancement. Furthermore, tomographic images were also acquired using both imaging modalities and cross-validated information of tumor location and size between these two modalities was revealed. The results demonstrate that the use of dual-labeled NPs can facilitate the dual-modal detection of tumors, information cross-validation, and direct comparison by combing fluorescence molecular tomography (FMT) and MRI.
Collapse
|
20
|
Gadolinium-functionalized aggregation-induced emission dots as dual-modality probes for cancer metastasis study. Adv Healthc Mater 2013; 2:1600-5. [PMID: 23836611 DOI: 10.1002/adhm.201300135] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2013] [Indexed: 01/15/2023]
Abstract
Understanding the localization and engraftment of tumor cells at postintravasation stage of metastasis is of high importance in cancer diagnosis and treatment. Advanced fluorescent probes and facile methodologies for cell tracing play a key role in metastasis studies. In this work, we design and synthesize a dual-modality imaging dots with both optical and magnetic contrast through integration of a magnetic resonance imaging reagent, gadolinium(III), into a novel long-term cell tracing probe with aggregation-induced emission (AIE) in far-red/near-infrared region. The obtained fluorescent-magnetic AIE dots have both high fluorescence quantum yield (25%) and T1 relaxivity (7.91 mM(-1) s(-1) ) in aqueous suspension. After further conjugation with a cell membrane penetrating peptide, the dual-modality dots can be efficiently internalized into living cells. The gadolinium(III) allows accurate quantification of biodistribution of cancer cells via intraveneous injection, while the high fluorescence provides engraftment information of cells at single cellular level. The dual-modality AIE dots show obvious synergistic advantages over either single imaging modality and hold great promises in advanced biomedical studies.
Collapse
|
21
|
Magnetic resonance and near-infrared imaging using a novel dual-modality nano-probe for dendritic cell tracking in vivo. Cytotherapy 2013; 16:699-710. [PMID: 24219906 DOI: 10.1016/j.jcyt.2013.09.006] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2013] [Revised: 09/14/2013] [Accepted: 09/28/2013] [Indexed: 01/11/2023]
Abstract
BACKGROUND AIMS The effect of cellular-based immunotherapy is highly correlated with the success of dendritic cells (DCs) homing to the draining lymph nodes (LNs) and interacting with antigen-specific CD4(+) T cells. In this study, a novel magneto-fluorescent nano-probe was used to track the in vivo migration of DCs to the draining LNs. METHODS A dual-modality nano-probe composed of superparamagnetic iron oxide (SPIO) and near-infrared fluorescent (NIRF) dye (NIR797) was developed, and its magnetic and optical contrasting properties were characterized. DCs generated from mouse bone marrow were co-cultured with the probe at a lower concentration of 10 μg/mL. The cell phenotype and function of DCs were also investigated by fluorescence-activated cell sorting analysis and mixed leukocyte reactivity assay. Labeled DCs were injected into the footpad of C57BL/6 mice. Afterward, magnetic resonance imaging, NIRF imaging, Perls staining and CD11c immunofluorescence were used to observe the migration of the labeled DCs into draining LNs. RESULTS The synthetic SPIO-NIR797 nano-probe had a desirable superparamagnetic and near-infrared behavior. Perls staining showed perfect labeling efficiency. The cell phenotypes, including CD11c, CD80, CD86 and major histocompatibility complex class II, as well as the T-cell activation potential of the mature DCs were insignificantly affected after incubation (P > 0.05). Labeled DCs migrating into LNs could be detected by both magnetic resonance imaging and NIRF imaging simultaneously, which was further confirmed by Perls staining and immunofluorescence. CONCLUSIONS The novel dual-modality SPIO-NIR797 nano-probe has highly biocompatible characteristics for labeling and tracking DCs, which can be used to evaluate cancer immunotherapy in clinical applications.
Collapse
|
22
|
Upconversion nanoparticles conjugated with Gd(3+) -DOTA and RGD for targeted dual-modality imaging of brain tumor xenografts. Adv Healthc Mater 2013; 2:1501-12. [PMID: 23630101 DOI: 10.1002/adhm.201300102] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2013] [Indexed: 01/03/2023]
Abstract
Glioblastoma multiforme (GBM) is the most common and malignant form of primary brain tumors in human. Small molecular magnetic resonance imaging (MRI) contrast agents are used for GBM diagnosis. However, conventional contrast agents have several limitations, such as low T1 relaxivity, short circulation half lives and absence of tumor targeting. Herein, we develop an upconversion nanoprobe labeled with Gd(3+) -DOTA and RGD (UCNP-Gd-RGD) for dual-modality imaging of glioblastoma. The preparation of UCNP-Gd-RGD starts with amine-functional upconversion nanoparticle core, followed by PEGylation, Gd(3+) DOTA conjugation and RGD labeling. The obtained UCNP-Gd-RGD has improved colloidal stability and reduced cytotoxicity compared with the UCNP core counterpart. Meanwhile, UCNP-Gd-RGD shows strong upconversion luminescence in deep-red region and three times enhancement of T1 relaxivity over Gd(3+) DOTA. Due to the recognition between UCNP-Gd-RGD and integrin αv β3 receptors, the nanoprobe specifically binds to U87MG cells, as evidenced by confocal microscopy and quantified by ICP-MS. Furthermore, UCNP-Gd-RGD demonstrates a preferential retention in subcutaneous U87MG tumor xenograft as shown in both in vivo upconversion fluorescence/MR imaging studies and ex vivo analysis. UCNP-Gd-RGD, conjugated with numerous RGD peptide and T1 contrast enhancing molecules, is promising for MR imaging of glioblastoma and delineating the tumor boundary before surgery. In addition, NIR-to-red upconversion characteristic of UCNP-Gd-RGD facilitates its potential intra-operative use for fluorescence-guided tumor resection.
Collapse
|