1
|
Retention of Mandibular Complete Overdentures using Mini Dental Implants (Ø < 3 mm) and Standard Diameter Implants (Ø > 3mm): A Systematic Review and Meta-Analysis of Randomised Controlled Trials. ORAL HEALTH & PREVENTIVE DENTISTRY 2024; 22:181-188. [PMID: 38713458 DOI: 10.3290/j.ohpd.b5282167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/08/2024]
Abstract
PURPOSE The objective of the present systematic review and meta-analysis was to assess randomised controlled trials (RCTs) which assessed the efficacy of mini dental implants (MDIs) and standard-diameter implants (SDIs) in retaining mandibular overdentures (MO). MATERIALS AND METHODS The focused question was "Is there a difference in the mechanical stability between MDIs and SDIs in retaining MO?" Indexed databases were searched up to and including November 2023 using different keywords. Boolean operators were used during the search. The literature was searched in accordance with the PRISMA guidelines. The PICO characteristics were: patients (P) = individuals with complete mandibular dentures requiring dental implants; Intervention (I) = placement of MDIs under mandibular dentures; Control (C) = placement of SDIs under mandibular dentures; Outcome (O) = comparison of stability between MDIs and SDIs in supporting mandibular dentures. Only RCTs were included. Risk of bias (RoB) was assessed using the Cochrane RoB tool. RESULTS Five RCTs were included. The numbers of participants ranged between 45 and 120 edentulous individuals wearing complete mandibular dentures. The mean age of patients ranged between 59.5 ± 8.5 and 68.3 ± 8.5 years. The number of MDIs and SDIs ranged between 22 and 152 and 10 and 80 implants, respectively. The follow-up duration ranged between one week and 12 months. Three RCTs reported an improvement in the quality of life (QoL) of all patients after stabilisation of mandibular dentures using MDIs or SDIs. In one RCT, peri-implant soft tissue profiles were comparable between MDIs and SDIs at the 1-year follow-up. The implant survival rate was reported in two RCTs, which were from 89% to 98% and 99% to 100% for MDIs and SDIs, respectively. All RCTs had a low RoB. CONCLUSION Mini dental implants represent a viable alternative to traditional standard-diameter implants when seeking optimal retention for mandibular overdentures.
Collapse
|
2
|
One-Piece Mini Dental Implant-Retained Mandibular Overdentures: 10-Year Clinical and Radiological Outcomes of a Non-Comparative Longitudinal Observational Study. J Funct Biomater 2024; 15:99. [PMID: 38667556 PMCID: PMC11051283 DOI: 10.3390/jfb15040099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 03/30/2024] [Accepted: 04/03/2024] [Indexed: 04/28/2024] Open
Abstract
This study presents the first 10-year follow-up investigation of the implant survival and peri-implant outcomes of one-piece mini dental implants (MDIs) retaining mandibular implant overdentures (IODs), including marginal bone level alterations (ΔMBLs), clinical peri-implant parameters, and complications. Twenty participants with horizontally atrophied mandibles received complete dentures and four MDIs (diameter 1.8 mm) at baseline. The dentures were converted into IODs with O-ring attachments. The 10-year follow-up comprised a radiological assessment of ΔMBLs, peri-implant parameters, as well as biological and technical complications. Results from a 10-year follow-up of 14 participants showed a 100% implant survival rate for all 56 implants. The mean ΔMBL after 10 years was -1.12 ± 0.80 mm, with 49 implants classified as successful (ΔMBL < 2 mm) and 7 implants with satisfactory survival (ΔMBL 2-4 mm). Time after implant placement significantly influenced ΔMBL, with stable MBLs after 5 years. The prosthetic survival rate after 10 years was 93%. ΔMBLs were not influenced by implant position or gender but were significantly smaller in subjects older than 65 years. Conclusively, one-piece MDIs with O-ring attachments offer a reliable treatment option for horizontally atrophied mandibles after 10 years, with high implant and prosthetic survival rates, potentially benefiting from advanced age regarding peri-implant bone stability.
Collapse
|
3
|
The Biomechanical Impact of Loss of an Implant in the Treatment with Mandibular Overdentures on Four Nonsplinted Mini Dental Implants: A Finite Element Analysis. MATERIALS (BASEL, SWITZERLAND) 2022; 15:8662. [PMID: 36500160 PMCID: PMC9739263 DOI: 10.3390/ma15238662] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 12/01/2022] [Accepted: 12/02/2022] [Indexed: 06/17/2023]
Abstract
The aim of this study was to evaluate the biomechanical impact, in terms of stress and displacement, at the level of a mandibular overdenture, on four mini dental implants (MDIs) after the loss of an implant. A three-dimensional virtual model was obtained by scanning the overdenture, and a biomechanical analysis was carried out, using the finite element method (FEM). The displacements of the overdenture and the equivalent von Mises stresses were evaluated using logarithmic scales. In the case of a mandibular overdenture on four MDIs inserted in the interforaminal area, the frontal loading generated the lowest values for the von Mises stresses, and the bilateral loading generated the least displacement when two implants were inserted in the canine area and two in the molar area. The highest von Mises stress was observed during frontal loading in the situation of the mandibular overdenture on four MDIs, two of which were inserted in the canine area and two in the molar area, following the loss of an implant in the canine area. The largest displacement was noted in the mandibular overdenture on four interforaminal MDIs during unilateral loading, following the loss of a distally inserted implant. The FEM analysis showed aspects that correlated with clinical observations, with predictive value. The concentration of von Mises stresses, and the occurrence of some displacements of the prosthodontic restoration, can explain the emergence of some complications in the overdenture's biodynamics, and the increased risk of fracture. Complications can be prevented by choosing a certain number of implants and a topographical distribution correlated with biomechanical aspects, and by proposing a correct occlusal scheme with optimal functional loading.
Collapse
|
4
|
Effect of Sinus Perforation with Flaplessly Placed Mini Dental Implants for Oral Rehabilitation: A 5-Year Clinical and Radiological Follow-Up. J Clin Med 2022; 11:jcm11154637. [PMID: 35956252 PMCID: PMC9369462 DOI: 10.3390/jcm11154637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 08/05/2022] [Accepted: 08/06/2022] [Indexed: 11/25/2022] Open
Abstract
Background: Flaplessly placed one-piece mini dental implants (MDI) are an option to support maxillary overdentures. Evenly distribution of the implants over the atrophic alveolar process implies a risk of accidental sinus perforation in the posterior area which could induce sinus-related pathology. Methods: Thirty-one patients received 5–6 maxillary MDIs. Schneiderian membrane swelling was assessed with CBCT at the deepest point of the sinus in the mid-sagittal plane prior to surgery (baseline), after 2 and 5 years. Additionally, subjective patient-reported rhinosinusitis complaints, the effect of smoking, and gender differences were investigated. Results: Mean thickness of the Schneiderian membrane was 2.87 mm at baseline, 3.15 mm at 2 years, and 4.30 mm at 5 years in 27 of 31 initially treated patients. MDI perforation was detected in 21/54 sinuses. At 2 years, perforation length does not affect membrane thickness whereas baseline swelling does. In smokers, each perforated mm induced 0.87 mm additional swelling. After 5 years, the effect of baseline swelling becomes smaller whereas perforation length became statistically significant, with 0.53 mm increase for every perforated mm. The effect of smoking lost its significance. No relations between gender, membrane thickness changes, or subjective clinical sinus complaints and MDI perforation were found. Conclusion: Accidental MDI sinus perforation induces Schneiderian membrane swelling but does not interfere with clinical sinusal outcome after 5 years.
Collapse
|
5
|
The Effect of Number and Distribution of Mini Dental Implants on Overdenture Stability: An In Vitro Study. MATERIALS 2022; 15:ma15092988. [PMID: 35591322 PMCID: PMC9104554 DOI: 10.3390/ma15092988] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Revised: 04/09/2022] [Accepted: 04/16/2022] [Indexed: 02/05/2023]
Abstract
The rotational movement of mini dental implants (MDIs) overdenture disturbs the function of the prosthesis. Many dentists place more MDIs to improve the overdenture stability; however, the influence of the MDIs number and distribution on the overdenture resistance to para-axial dislodgment has not been investigated. Seven resin models simulating atrophic mandibles housed twenty MDIs placed according to seven arrangements. Acrylic overdentures were fabricated for each cast and were dislodged five times in lateral, anterior and posterior directions, and the peak load dislodgment was measured. Each overdenture underwent 540 axial removal/placement cycles. The para-axial dislodgments were measured again, and data were compared. Dislodgment force values were measured in all directions, and the data were analysed using analysis of variance ANOVA and post hoc (p < 0.05). After six months of simulated placement/removal, increasing the MDI number showed a difference in resistance to para-axial dislodgment. The distribution affected the resistance to dislodgment in some directions. The inter-implant distance of 27 mm provided better resistance to posterior dislodgment than placing two MDIs close together at 19 mm. The placement of three MDIs at any distribution showed no significant difference except for resistance to posterior dislodgment. FourMDIs placed at any distribution showed a significant difference in all groups in all tested directions. The resistance to the para-axial dislodgment of MDI overdenture could improve with the increasing MDIs number and careful planning of MDI distribution.
Collapse
|
6
|
Comparing Masticatory Performance of Maxillary Mini Dental Implant Overdentures, Complete Removable Dentures and Dentate Subjects. J Clin Med 2021; 10:jcm10215006. [PMID: 34768527 PMCID: PMC8584742 DOI: 10.3390/jcm10215006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 10/20/2021] [Accepted: 10/26/2021] [Indexed: 12/29/2022] Open
Abstract
Background: Mini dental implant (MDI) overdenture rehabilitation for the edentulous maxilla is a valuable, less invasive and affordable treatment alternative for complete removable dentures (CRD). However, comparative quantification of masticatory performance in different oral conditions are scarce. Purpose: This study compares objective masticatory performance of dentate groups, maxillary CRD and MDI overdentures and subjective masticatory performance in maxillary CRD and MDI overdentures. Materials and Methods: Four groups were defined, age 20+ dentate dental students (DS), age 50+ complete dentate subjects (DP), age 50+ maxillary CRD or MDI overdentures/dentate mandible. Objective masticatory performance was evaluated by measuring circular Variance of Hue (VOH) or the mixture degree of two-color chewing gum (Hue-check View Gum® Test). Additionally, subjective masticatory comparison was investigated in the CRD and MDI groups, with a visual analogue scale (VAS) for different food consistencies and the Oral Health Related Quality of Life (OHRQL) OHIP-14 questionnaire. Results: The mean VOH was 0.11 (SD 0.50, range 0.05–0.27) for the dentate dental 20+ students, 0.13 (SD 0.08, range 0.03–0.31) for the 50+ dentate group (p = 0.774), 0.41 (SD 0.41, range 0.14–0.76) for the CRD group and 0.39 (SD 0.18, range 0.07–0.76) for the MDI group (p = 0.725). Based on the VAS scores, no improvement was found between the CRD and the MDI overdenture group (p > 0.050). The mean OHIP-14 total score was 12.10 (SD 15.87, range 0–56) for CRD, while the MDI group (p = 0.039) saw a significant improvement to 2.85 (SD 2.85, range 0–15). Conclusion: Comparable results in objective masticatory performance were registered in dentate 20+ and 50+ subjects with a remarkable inferior outcome for the CRD and MDI group. Compared to CRD, MDI overdentures revealed no substantial improvement in subjective and objective masticatory performance. However, for MDI a significant increase in OHRQL was apparent.
Collapse
|
7
|
Narrow Diameter Dental Implants as an Alternative Treatment for Atrophic Alveolar Ridges. Systematic Review and Meta-Analysis. MATERIALS 2021; 14:ma14123234. [PMID: 34208369 PMCID: PMC8231146 DOI: 10.3390/ma14123234] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 06/06/2021] [Accepted: 06/07/2021] [Indexed: 01/10/2023]
Abstract
To determine the marginal bone loss and the survival, success and failure rates of narrow dental implants, a systematic literature search was carried out in the MEDLINE (Pubmed), Cochrane, Scopus, and Scielo databases for articles published between 2010 and 2021. The exclusion criteria were: systematic reviews, case reports, expert opinions; animal studies; samples of less than 10 subjects; follow-up periods of less than 36 months; smokers of minimum 10 cigarettes/day; and articles about mini-implants for orthodontic anchorage. Meta-analyses were performed to assess marginal bone loss and implant survival, success, and failure rates. Fifteen studies were included: 7 clinical trials, 3 randomized clinical trials, 3 cohort studies, and 2 case series. The total number of subjects was 773, in whom 1245 implants were placed. The survival rate for the narrow diameter implants was 97%, the success rate 96.8%, and the failure rate 3%. Marginal bone loss was 0.821 mm. All these data were evaluated at 36 months. Based on the literature, it can be considered that there is sufficient evidence to consider small diameter implants a predictable treatment option. These show favorable survival and success rates and marginal bone loss. All of them are comparable to those of standard diameter dental implants.
Collapse
|
8
|
Three-Dimensional Radiographic Outcome of Free-Handed Flaplessly Placed Mini Dental Implants in Edentulous Maxillae after 2-Years Function. J Clin Med 2020; 9:jcm9072120. [PMID: 32635649 PMCID: PMC7408764 DOI: 10.3390/jcm9072120] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 06/22/2020] [Accepted: 06/29/2020] [Indexed: 12/15/2022] Open
Abstract
Background: Free-handed, flaplessly placed mini dental implants (MDIs) are a valuable, more affordable and minimally invasive treatment to support overdentures in fully edentulous jaws, especially for medically compromised patients. However, critical 3D radiographic evaluation is lacking. This multicenter prospective case series assessed clinical outcome and carried out 3D- cone-beam computerized tomography (CBCT) analysis of free-handed flaplessly placed one-piece maxillary MDIs by an experienced maxillofacial surgeon. Methods: Thirty-one patients suffering from an ill-fitting maxillary denture relating to compromised bone volume (as confirmed on CBCT), with a dentate mandible, were selected. They received 5–6 MDIs free-hand flaplessly placed and mentally guided with preoperative CBCT. Final connection and attachment activation took place six months later. After two years each implant was individually assessed with CBCT for perforations on eight sites. Implant survival, prosthetic failure, clinical stability and sinus/nasal complaints were registered after three years. Results: 32/185 (17.3%) MDIs failed during the provisional loading with non-activated attachments; 17 replacements in 10 patients were performed. Of the 170 actively loaded 170 MDIs, 82.3% survived and 27/31 prostheses (87%) were fully functional. In total 98/170 MDIs showed no perforation. Based on 1360 CBCT observations, 231 perforations (16.9%) were registered. Of most perforations 37 (25%) were observed at the apical tip and 37 were positioned (21%) into the sinus/nasal cavity, although without clinical complaints. Conclusions: Given the compromised population, the minimally invasive procedure and the low treatment cost involved, a failure rate of 17% is substantial, however clinically acceptable given the critical bone condition. However, even in experienced surgical hands, freehanded and flapless placement yield a high risk for implant perforation, although this did not necessarily lead to complications.
Collapse
|
9
|
Clinical outcomes and bone-level alterations around one-piece mini dental implants retaining mandibular overdentures: 5-year follow-up of a prospective cohort study. Clin Oral Implants Res 2020; 31:549-556. [PMID: 32096255 DOI: 10.1111/clr.13591] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Revised: 02/11/2020] [Accepted: 02/15/2020] [Indexed: 12/14/2022]
Abstract
OBJECTIVES To report on the clinical outcomes of one-piece mini dental implants (MDIs) retaining mandibular implant overdentures (IODs), including marginal bone-level alterations (ΔMBLs), clinical peri-implant parameters, and technical- and biological complications during a 5-year follow-up. The null hypothesis was that ΔMBLs would be equal in subjects older than 65 years relative to younger subjects. MATERIALS AND METHODS Four 1.8-mm diameter one-piece MDIs with ball attachments were placed in the interforaminal region of 20 edentulous subjects. The existing complete dentures were converted to IODs. Standardized radiographs of each implant were taken at implant placement (baseline) and during the five-year follow-up. ΔMBLs and potential influencing factors were evaluated, and peri-implant parameters, and biological and technical complications were recorded. RESULTS The implant and prosthetic survival rates were both 100%. IODs fractured in seven participants. The overall mean ΔMBL after 5 years was -1.18 mm (standard deviation: 0.79 mm). ΔMBLs per month were most pronounced within the first 3 months after implant placement. ΔMBLs were not influenced by the implant location, the presence of keratinized mucosa, or gender. However, ΔMBLs were significantly smaller in subjects older than 65 years (p = .007). CONCLUSIONS One-piece MDIs retaining mandibular IODs with O-ring attachments are a predictable treatment option, providing stable peri-implant bone and soft tissue conditions over a mid-term follow-up. Incorporating a metal reinforcement can prevent denture fracturing when converting a complete denture into an IOD. The presence of keratinized mucosa does not necessarily lead to decreased bone-level changes. Advanced age might be beneficial in terms of peri-implant bone stability.
Collapse
|
10
|
The influence of implant body and thread design of mini dental implants on the loading of surrounding bone: a finite element analysis. BIOMED ENG-BIOMED TE 2017; 62:393-405. [PMID: 28358711 DOI: 10.1515/bmt-2016-0002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2016] [Accepted: 11/15/2016] [Indexed: 11/15/2022]
Abstract
Mini dental implants (MDI) were once thought of as transitional implants for treatment in selected clinical situations. Their reduced diameter makes them a very attractive option for patients with poor tolerance to maxillary and mandibular prostheses. Using the method of finite element analysis, a series of different designed MDI prototypes have been investigated. The prototypes differed in the geometry of implant body and/or design of implant head. The load transfer of the implant prototypes to the idealised alveolar bone has been regarded and the prototypes have been compared to each other and to a number of standard commercial implants. The prototype models have been virtually placed in the idealised bone with a cortical thickness of 1.5 mm and loaded laterally 30° from the implant's long axis. The condition of immediate loading was assumed for the numerical analyses through defining a contact interface between the implant and bone bed. The numerical analysis in this study showed that the design of the investigated prototype MDI of group 3 (mini-ball head) is the most advantageous design.
Collapse
|
11
|
Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study. ORAL & IMPLANTOLOGY 2016; 9:202-212. [PMID: 28042449 DOI: 10.11138/orl/2016.9.4.202] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. PURPOSE Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. MATERIALS AND METHODS Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. RESULTS There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. CONCLUSIONS Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. CLINICAL IMPLICATIONS Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force.
Collapse
|
12
|
Evaluation of Stress Distribution of Mini Dental Implant-Supported Overdentures in Complete Cleft Palate Models: A Three-Dimensional Finite Element Analysis Study. Cleft Palate Craniofac J 2014; 53:73-83. [PMID: 24919124 DOI: 10.1597/13-248] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE Mini dental implants could be an alternative treatment method for prosthetic treatment of edentulous cleft palate. The aim of this study was to analyze stress distribution around the cortical bone and different plans using a varied number of mini dental implants in edentulous unilateral complete cleft palates. MATERIALS AND METHODS Three edentulous maxillary models were modified to create unilateral complete cleft palates. Mini dental implants (2.4 × 15 mm) were located as two mini implants at the premolar region, four mini implants at the premolar and molar region, and six mini implants at the first premolar, second premolar, and first molar regions in the models, respectively. Mucosa, o-ring/ball attachments, and overdentures were simulated. Vertical and horizontal loads of 100 N were applied on both the right and left molar teeth of the overdenture for each model. Maximum and minimum principal stress values and the distribution at cortical bone around the implants and cleft palates were evaluated by finite element analysis. RESULTS Stress values under vertical loads were lower than values under horizontal loadings for all models. Stress values were found to be lower in the first model than in the second and third models. The highest stress values were found around implants in the second model. The unilateral feature of a complete cleft pattern affected the stress distribution. CONCLUSION Stresses occured mostly around implants when the overdenture was supported by six implants; however, the stress distribution around implants was low with two implants because of tissue support.
Collapse
|
13
|
Imaging technique for the complete edentulous patient treated conventionally or with mini implant overdenture. J Med Life 2013; 6:86-92. [PMID: 23599828 PMCID: PMC3624656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2012] [Accepted: 01/25/2013] [Indexed: 11/05/2022] Open
Abstract
RATIONALE The imaging methods are more and more used in the clinical process of modern dentistry. Once the implant based treatment alternatives are nowadays seen as being the standard of care in edentulous patients, these techniques must be integrated in the complete denture treatment. AIM The study presents some evaluation techniques for the edentulous patient treated by conventional dentures or mini dental implants (mini SKY Bredent) overdentures, using the profile teleradiography. These offer data useful for an optimal positioning of the artificial teeth and the mini dental implants, favoring to obtain an esthetic and functional treatment outcome. We proposed also a method to conceive a simple surgical guide that allows the prosthetically driven implants placement. MATERIAL AND METHOD Clinical case reports were made, highlighting the importance of cephalometric evaluation on lateral teleradiographs in complete edentulous patients. A clinical case that gradually reports the surgical guide preparation (Bredent silicon radio opaque), in order to place the mini dental implants in the best prosthetic and anatomic conditions, was presented. CONCLUSIONS The profile teleradiograph is a useful tool for the practitioner. It allows establishing the optimal site for implant placement, in a good relation with the overdenture. The conventional denture can be easily and relatively costless transformed in a surgical guide used during implant placement.
Collapse
|
14
|
Abstract
Mini dental implants (MDI) are ultra-small diameter (l.8 mm width), biocompatible titanium alloy implant screws, conceived and designed over 20 years ago by a board-certified Manhattan dentist, Sendax Victor. Dr. R. A. Bulard added a single-piece “O-ball” design to Dr. Sendax Victor concept. These implants can be used in atrophic ridges, flabby ridges, or in other cases where there is denture instability or lack of retention due to poor availability of residual bone. In this article, a case report of 55-year-old female patient is presented, with a severely atrophic mandibular ridge that was managed by the MDI system with an overdenture.
Collapse
|