Wang X, Rosenzweig S, Roeloffs V, Blumenthal M, Scholand N, Tan Z, Holme HCM, Unterberg-Buchwald C, Hinkel R, Uecker M. Free-breathing myocardial T
1 mapping using inversion-recovery
radial FLASH and motion-resolved model-based reconstruction.
Magn Reson Med 2023;
89:1368-1384. [PMID:
36404631 PMCID:
PMC9892313 DOI:
10.1002/mrm.29521]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 09/22/2022] [Accepted: 10/20/2022] [Indexed: 11/22/2022]
Abstract
PURPOSE
To develop a free-breathing myocardialT 1 $$ {\mathrm{T}}_1 $$ mapping technique using inversion-recovery (IR) radial fast low-angle shot (FLASH) and calibrationless motion-resolved model-based reconstruction.
METHODS
Free-running (free-breathing, retrospective cardiac gating) IR radial FLASH is used for data acquisition at 3T. First, to reduce the waiting time between inversions, an analytical formula is derived that takes the incompleteT 1 $$ {\mathrm{T}}_1 $$ recovery into account for an accurateT 1 $$ {\mathrm{T}}_1 $$ calculation. Second, the respiratory motion signal is estimated from the k-space center of the contrast varying acquisition using an adapted singular spectrum analysis (SSA-FARY) technique. Third, a motion-resolved model-based reconstruction is used to estimate both parameter and coil sensitivity maps directly from the sorted k-space data. Thus, spatiotemporal total variation, in addition to the spatial sparsity constraints, can be directly applied to the parameter maps. Validations are performed on an experimental phantom, 11 human subjects, and a young landrace pig with myocardial infarction.
RESULTS
In comparison to an IR spin-echo reference, phantom results confirm goodT 1 $$ {\mathrm{T}}_1 $$ accuracy, when reducing the waiting time from 5 s to 1 s using the new correction. The motion-resolved model-based reconstruction further improvesT 1 $$ {\mathrm{T}}_1 $$ precision compared to the spatial regularization-only reconstruction. Aside from showing that a reliable respiratory motion signal can be estimated using modified SSA-FARY, in vivo studies demonstrate that dynamic myocardialT 1 $$ {\mathrm{T}}_1 $$ maps can be obtained within 2 min with good precision and repeatability.
CONCLUSION
Motion-resolved myocardialT 1 $$ {\mathrm{T}}_1 $$ mapping during free-breathing with good accuracy, precision and repeatability can be achieved by combining inversion-recovery radial FLASH, self-gating and a calibrationless motion-resolved model-based reconstruction.
Collapse