1
|
Ultrasound Pressure Estimation for Diagnosing Portal Hypertension in Patients Undergoing Dialysis for Chronic Kidney Disease. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2022; 41:2181-2189. [PMID: 34850412 PMCID: PMC9156659 DOI: 10.1002/jum.15897] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 10/08/2021] [Accepted: 10/27/2021] [Indexed: 06/13/2023]
Abstract
OBJECTIVES Hepatic venous pressure gradient (HVPG) is considered the standard in quantifying portal hypertension, but can be unreliable in dialysis patients. A noninvasive ultrasound technique, subharmonic-aided pressure estimation (SHAPE), may be a valuable surrogate of these pressure estimates. This study compared SHAPE and HVPG with pathology findings for fibrosis in dialysis patients. METHODS This was a subgroup study from an IRB-approved trial that included 20 patients on dialysis undergoing SHAPE examinations of portal and hepatic veins using a modified Logiq 9 scanner (GE, Waukesha, WI), during infusion of Sonazoid (GE Healthcare, Oslo, Norway). SHAPE was compared to HVPG and pathology findings using the Ludwig-Batts scoring system for fibrosis. Logistic regression, ROC analysis, and t-tests were used to compare HVPG and SHAPE with pathological findings of fibrosis. RESULTS Of 20 cases, 5 had HVPG values corresponding to subclinical and clinical portal hypertension (≥6 and ≥10 mmHg, respectively) while 15 had normal HVPG values (≤5 mmHg). SHAPE and HVPG correlated moderately (r = 0.45; P = .047). SHAPE showed a trend toward correlating with fibrosis (r = 0.42; P = .068), while HVPG did not (r = 0.18; P = .45). SHAPE could differentiate between mild (stage 0-1) and moderate to severe (stage 2-4) fibrosis (-10.4 ± 4.9 dB versus -5.4 ± 3.2 dB; P = .035), HVPG could not (3.0 ± 0.6 mmHg versus 4.8 ± 0.7 mmHg; P = .30). ROC curves showed a diagnostic accuracy for SHAPE of 80%, while HVPG reached 76%. CONCLUSION Liver fibrosis staging in dialysis patients evaluated for portal hypertension appears to be more accurately predicted by SHAPE than by HVPG; albeit in a small sample size.
Collapse
|
2
|
3D Harmonic and Subharmonic Imaging for Characterizing Breast Lesions: A Multi-Center Clinical Trial. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2022; 41:1667-1675. [PMID: 34694019 PMCID: PMC9884499 DOI: 10.1002/jum.15848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Accepted: 09/20/2021] [Indexed: 05/12/2023]
Abstract
OBJECTIVE Breast cancer is the most frequent type of cancer among women. This multi-center study assessed the ability of 3D contrast-enhanced ultrasound to characterize suspicious breast lesions using clinical assessments and quantitative parameters. METHODS Women with suspicious breast lesions scheduled for biopsy were enrolled in this prospective, study. Following 2D grayscale ultrasound and power Doppler imaging (PDI), a contrast agent (Definity; Lantheus) was administrated. Contrast-enhanced 3D harmonic imaging (HI; transmitting/receiving at 5.0/10.0 MHz), as well as 3D subharmonic imaging (SHI; transmitting/receiving at 5.8/2.9 MHz), were performed using a modified Logiq 9 scanner (GE Healthcare). Five radiologists independently scored the imaging modes (including standard-of-care imaging) using a 7-point BIRADS scale as well as lesion vascularity and diagnostic confidence. Parametric volumes were constructed from time-intensity curves for vascular heterogeneity, perfusion, and area under the curve. Diagnostic accuracy was determined relative to pathology using receiver operating characteristic (ROC) and reverse, step-wise logistical regression analyses. The κ-statistic was calculated for inter-reader agreement. RESULTS Data were successfully acquired in 219 cases and biopsies indicated 164 (75%) benign and 55 (25%) malignant lesions. SHI depicted more anastomoses and vascularity than HI (P < .021), but there were no differences by pathology (P > .27). Ultrasound achieved accuracies of 82 to 85%, which was significantly better than standard-of-care imaging (72%; P < .03). SHI increased diagnostic confidence by 3 to 6% (P < .05), but inter-reader agreements were medium to low (κ < 0.52). The best regression model achieved 97% accuracy by combining clinical reads and parametric SHI. CONCLUSIONS Combining quantitative 3D SHI parameters and clinical assessments improves the characterization of suspicious breast lesions.
Collapse
|
3
|
A Noninvasive Ultrasound Based Technique to Identify Treatment Responders in Patients with Portal Hypertension. Acad Radiol 2021; 28 Suppl 1:S128-S137. [PMID: 33341374 DOI: 10.1016/j.acra.2020.11.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 11/18/2020] [Accepted: 11/28/2020] [Indexed: 02/07/2023]
Abstract
RATIONALE AND OBJECTIVE Subharmonic aided pressure estimation (SHAPE) is based on the inverse relationship between the subharmonic amplitude of ultrasound contrast microbubbles and ambient pressure. The aim of this study was to verify if SHAPE can accurately monitor disease progression in patients identified with portal hypertension. MATERIALS & METHODS A modified Logiq 9 scanner with a 4C curvi-linear probe (GE, Waukesha, WI) was used to acquire SHAPE data (transmitting and receiving at 2.5 and 1.25 MHz, respectively) using Sonazoid (GE Healthcare, Oslo, Norway; FDA IND 124,465). Twenty-one (median age 59 years; 12 Males) of the 178 patients enrolled in this institutional review board approved study (14F.113) were identified as having clinically significant portal hypertension based on their hepatic venous pressure gradient results ≥ 10 mmHg. Repeat SHAPE examinations were done every 6.2 months. Liver function tests and clinical indicators were used to establish treatment response. RESULTS Of the 21 portal hypertensive subjects, 11 had successful follow up scans with an average follow up time of 6.2 months. There was a significantly larger SHAPE signal reduction in the group who were classified as treatment responders (n = 10; -4.01±3.61 dB) compared to the single nonresponder (2.33 dB; p < 0.001). Results for responders matched the corresponding clinical outcomes of improved model for end stage liver disease (MELD) scores, improvement in underlying cause of portal hypertension, improved liver function tests and reduced ascites. CONCLUSION SHAPE can potentially monitor disease progression in portal hypertensive patients and hence, may help clinicians in patient management. A larger study would further validate this claim.
Collapse
|
4
|
Characterization of Adnexal Masses Using Contrast-Enhanced Subharmonic Imaging: A Pilot Study. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:977-985. [PMID: 31769529 PMCID: PMC7174081 DOI: 10.1002/jum.15183] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Revised: 10/14/2019] [Accepted: 10/31/2019] [Indexed: 05/28/2023]
Abstract
OBJECTIVES This pilot study evaluated whether contrast-enhanced subharmonic imaging (SHI) could be used to characterize adnexal masses before surgical intervention. METHODS Ten women (with 12 lesions) scheduled for surgery of an ovarian mass underwent an SHI examination of their adnexal region using a modified LOGIQ E9 scanner (GE Healthcare, Waukesha, WI) with an endocavitary transducer, in which digital clips were acquired by pulse destruction-replenishment SHI across the lesions. Time-intensity curves were created offline to quantitatively evaluate SHI parameters (fractional tumor perfusion, peak contrast intensity, time to peak contrast enhancement, and area under the time-intensity curve), which were compared to pathologic characterizations of the lesions. RESULTS Of the 12 masses, 8 were benign, and 4 were malignant. A qualitative analysis of the SHI images by an experienced radiologist resulted in diagnostic accuracy of 70%, compared to 56% without contrast, whereas an inexperienced radiologist improved from 50% to 58% accuracy, demonstrating the benefit of SHI. A quantitative analysis of SHI parameters produced diagnostic accuracy as high as 81%. Peak contrast intensity was significantly greater in malignant than benign masses (mean ± SD, 0.109 ± 0.088 versus 0.046 ± 0.030 arbitrary units; P = .046). Malignant masses also showed significantly greater perfusion than benign masses (24.79% ± 25.34% versus 7.62% ± 6.50%; P = .045). When the radiologist reads were combined with the most predictive quantitative SHI parameter (percent perfusion), diagnostic accuracy improved to 84% for the experienced radiologist and 96% for the novice radiologist. CONCLUSIONS Results indicate that SHI for presurgical characterization of adnexal masses may improve the determination of malignancy and diagnostic accuracy, albeit based on a small sample size.
Collapse
|
5
|
Optimal Control of SonoVue Microbubbles to Estimate Hydrostatic Pressure. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:557-567. [PMID: 31634833 PMCID: PMC7053253 DOI: 10.1109/tuffc.2019.2948759] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
The measurement of cardiac and aortic pressures enables diagnostic insight into cardiac contractility and stiffness. However, these pressures are currently assessed invasively using pressure catheters. It may be possible to estimate these pressures less invasively by applying microbubble ultrasound contrast agents as pressure sensors. The aim of this study was to investigate the subharmonic response of the microbubble ultrasound contrast agent SonoVue (Bracco Spa, Milan, Italy) at physiological pressures using a static pressure phantom. A commercially available cell culture cassette with Luer connections was used as a static pressure chamber. SonoVue was added to the phantom, and radio frequency data were recorded on the ULtrasound Advanced Open Platform (ULA-OP). The mean subharmonic amplitude over a 40% bandwidth was extracted at 0-200-mmHg hydrostatic pressures, across 1.7-7.0-MHz transmit frequencies and 3.5%-100% maximum scanner acoustic output. The Rayleigh-Plesset equation for single-bubble oscillations and additional hysteresis experiments were used to provide insight into the mechanisms underlying the subharmonic pressure response of SonoVue. The subharmonic amplitude of SonoVue increased with hydrostatic pressure up to 50 mmHg across all transmit frequencies and decreased thereafter. A decreasing microbubble surface tension may drive the initial increase in the subharmonic amplitude of SonoVue with hydrostatic pressure, while shell buckling and microbubble destruction may contribute to the subsequent decrease above 125-mmHg pressure. In conclusion, a practical operating regime that may be applied to estimate cardiac and aortic blood pressures from the subharmonic signal of SonoVue has been identified.
Collapse
|
6
|
Three-Dimensional Subharmonic Aided Pressure Estimation for Assessing Arterial Plaques in a Rabbit Model. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2019; 38:1865-1873. [PMID: 30560581 PMCID: PMC7081075 DOI: 10.1002/jum.14884] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2018] [Accepted: 10/29/2018] [Indexed: 05/07/2023]
Abstract
OBJECTIVES To investigate 3-dimensional subharmonic aided pressure estimation (SHAPE) for measuring intraplaque pressure and the pressure gradient across the plaque cap as novel biomarkers for potentially predicting plaque vulnerability. METHODS Twenty-seven rabbits received a high-cholesterol diet for 2 weeks before a balloon catheter injury to denude the endothelium of the aorta, followed by 8 to 10 weeks of the high-cholesterol diet to create arteriosclerotic plaques. SHAPE imagings of the resulting plaques were performed 12, 16, and 20 weeks after injury using a LOGIQ 9 scanner with a 4D10L probe (GE Healthcare, Milwaukee, WI) before and during an infusion of Definity (Lantheus Medical Imaging, North Billerica, MA) and Sonazoid (GE Healthcare, Oslo, Norway). The ratios of the maximum subharmonic magnitudes at baseline and during the infusion were correlated with the intraplaque pressure and pressure gradient across the plaque cap obtained from direct measurements. RESULTS Ten rabbits died prematurely after the balloon injury procedure or due to toxicity from the high-cholesterol diet, whereas 2 rabbits were excluded for other conditions. Five rabbits were scanned in the 12-, 16-, and 20-week groups, respectively. Even after 20 weeks, the plaques that developed were very small (mean ± SD, 0.9 ± 0.4 × 0.14 ± 0.05 cm). Definity performed better than Sonazoid in this application but still only achieved a moderate correlation with pressure across the plaque cap (Definity, r = -0.40; Sonazoid, r = 0.22) and intraplaque pressure (Definity, r = -0.19; Sonazoid, r = -0.11). CONCLUSIONS Initial findings from plaque pressure estimation using 3-dimensional SHAPE technique showed only moderate correlations with reference standards, but that may be have been due to weaknesses in the animal model studied.
Collapse
|
7
|
Abstract
Subharmonic-aided pressure estimation (SHAPE) estimates hydrostatic pressure using the inverse relationship with subharmonic amplitude variations of ultrasound contrast agents (UCAs). We studied the impact of varying incident acoustic outputs (IAO), UCA concentration, and hematocrit on SHAPE. A Logiq 9 scanner with a 4C curvilinear probe (GE, Milwaukee, Wisconsin) was used with Sonazoid (GE Healthcare, Oslo, Norway) transmitting at 2.5 MHz and receiving at 1.25 MHz. An improved IAO selection algorithm provided improved correlations ( r from -0.85 to -0.95 vs. -0.39 to -0.98). There was no significant change in SHAPE gradient as the pressure increased from 10 to 40 mmHg and hematocrit concentration was tripled from 1.8 to 4.5 mL/L (Δ0.00-0.01 dB, p = 0.18), and as UCA concentration was increased from 0.2 to 1.2 mL/L (Δ0.02-0.05 dB, p = 0.75). The results for the correlation between the SHAPE gradient and hematocrit values for patients ( N = 100) in an ongoing clinical trial were also calculated showing a poor correlation value of 0.14. Overall, the SHAPE gradient is independent of hematocrit and UCA concentration. An improved algorithm for IAO selection will make SHAPE more accurate.
Collapse
|
8
|
Subharmonic and Endoscopic Contrast Imaging of Pancreatic Masses: A Pilot Study. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2018; 37:123-129. [PMID: 28681437 PMCID: PMC5752617 DOI: 10.1002/jum.14310] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 03/13/2017] [Accepted: 03/23/2017] [Indexed: 05/10/2023]
Abstract
OBJECTIVES To use subharmonic imaging (SHI) to depict the vascularity of pancreatic masses compared to contrast-enhanced endoscopic ultrasound (EUS) and pathologic results. METHODS Sixteen patients scheduled for biopsy of a pancreatic mass were enrolled in an Institutional Review Board-approved study. Pulse-inversion SHI (transmitting/receiving at 2.5/1.25 MHz) was performed on a LOGIQ 9 system (GE Healthcare, Milwaukee, WI) with a 4C transducer, whereas contrast harmonic EUS (transmitting/receiving at 4.7/9.4 MHz) was performed with a radial endoscope (GF-UTC180; Olympus Corporation, Tokyo, Japan) connected to a ProSound SSD α-10 scanner (Hitachi Aloka, Tokyo, Japan). Two injections of the contrast agent Definity (Lantheus Medical Imaging, North Billerica, MA) were administrated (0.3-0.4 and 0.6-0.8 mL for EUS and SHI, respectively). Contrast-to-tissue ratios (CTRs) in the mass and an adjacent vessel were calculated. Four physicians independently scored the images (benign to malignant) for diagnostic accuracy and inter-reader agreement. RESULTS One patient dropped out before imaging, leaving 11 adenocarcinomas, 1 gastrointestinal stromal tumor with pancreatic infiltration, and 3 benign masses. Marked subharmonic signals were obtained in all patients, with intratumoral blood flow clearly visualized with SHI. Significantly greater CTRs were obtained in the masses with SHI than with EUS (mean ± SD, 1.71 ± 1.63 versus 0.63 ± 0.89; P = .016). There were no differences in the CTR in the surrounding vessels or when grouped by pathologic results (P > .60). The accuracies for contrast EUS and SHI were low (<53%), albeit with a greater κ value for SHI (0.34) than for EUS (0.13). CONCLUSIONS Diagnostic accuracy of contrast EUS and transabdominal SHI for assessment of pancreatic masses was quite low in this pilot study. However, SHI had improved tumoral CTRs relative to contrast EUS.
Collapse
|
9
|
Effect of Pulse Shaping on Subharmonic Aided Pressure Estimation In Vitro and In Vivo. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2017; 36:3-11. [PMID: 27943411 PMCID: PMC5191985 DOI: 10.7863/ultra.15.11106] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Accepted: 04/15/2016] [Indexed: 05/10/2023]
Abstract
OBJECTIVES Subharmonic imaging (SHI) is a technique that uses the nonlinear oscillations of microbubbles when exposed to ultrasound at high pressures transmitting at the fundamental frequency ie, fo and receiving at half the transmit frequency (ie, fo /2). Subharmonic aided pressure estimation (SHAPE) is based on the inverse relationship between the subharmonic amplitude of the microbubbles and the ambient pressure change. METHODS Eight waveforms with different envelopes were optimized with respect to acoustic power at which the SHAPE study is most sensitive. The study was run with four input transmit cycles, first in vitro and then in vivo in three canines to select the waveform that achieved the best sensitivity for detecting changes in portal pressures using SHAPE. A Logiq 9 scanner with a 4C curvi-linear array was used to acquire 2.5 MHz radio-frequency data. Scanning was performed in dual imaging mode with B-mode imaging at 4 MHz and a SHI contrast mode transmitting at 2.5 MHz and receiving at 1.25 MHz. Sonazoid, which is a lipid stabilized gas filled bubble of perfluorobutane, was used as the contrast agent in this study. RESULTS A linear decrease in subharmonic amplitude with increased pressure was observed for all waveforms (r from -0.77 to -0.93; P < .001) in vitro. There was a significantly higher correlation of the SHAPE gradient with changing pressures for the broadband pulses as compared to the narrowband pulses in both in vitro and in vivo results. The highest correlation was achieved with a Gaussian windowed binomial filtered square wave with an r-value of -0.95. One of the three canines was eliminated for technical reasons, while the other two produced very similar results to those obtained in vitro (r from -0.72 to -0.98; P <.01). The most consistent in vivo results were achieved with the Gaussian windowed binomial filtered square wave (r = -0.95 and -0.96). CONCLUSIONS Using this waveform is an improvement to the existing SHAPE technique (where a square wave was used) and should make SHAPE more sensitive for noninvasively determining portal hypertension.
Collapse
|
10
|
Comparing Quantitative Immunohistochemical Markers of Angiogenesis to Contrast-Enhanced Subharmonic Imaging. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2016; 35:1839-1847. [PMID: 27388814 PMCID: PMC7172498 DOI: 10.7863/ultra.15.05024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Accepted: 12/14/2015] [Indexed: 06/06/2023]
Abstract
OBJECTIVES Different methods for obtaining tumor neovascularity parameters based on immunohistochemical markers were compared to contrast-enhanced subharmonic imaging (SHI). METHODS Eighty-five athymic nude female rats were implanted with 5 × 10(6) breast cancer cells (MDA-MB-231) in the mammary fat pad. The contrast agent Definity (Lantheus Medical Imaging, North Billerica, MA) was injected, and SHI was performed using a modified Sonix RP scanner (Analogic Ultrasound, Richmond, British Columbia, Canada) with a L9-4 linear array (transmitting/receiving frequencies, 8/4 MHz). Afterward, specimens were stained for endothelial cells (CD31), vascular endothelial growth factor (VEGF), and cyclooxygenase 2 (COX-2). Tumor neovascularity was assessed in 4 different ways using a histomorphometry system (×100 magnification: (1) over the entire tumor; (2) in small sub-regions of interest (ROIs); (3) in the tumor periphery and centrally; and (4) in 3 regions of maximum marker expression (so-called hot spots). Results from specimens and from SHI were compared by linear regression. RESULTS Fifty-four rats (64%) showed tumor growth, and 38 were successfully imaged. Subharmonic imaging depicted the tortuous morphologic characteristics of tumor neovessels and delineated small areas of necrosis. The immunohistochemical markers did not correlate with SHI measures over the entire tumor area or over small sub-ROIs (P > .18). However, when the specimens were subdivided into central and peripheral regions, COX-2 and VEGF correlated with SHI in the periphery (r = -0.42; P = .005; and r = -0.32; P = .049, respectively). CONCLUSIONS When comparing quantitative contrast measures of tumor neovascularity to immunohistochemical markers of angiogenesis in xenograft models, ROIs corresponding to the biologically active region should be used to account for tumor heterogeneity.
Collapse
|
11
|
Abstract
OBJECTIVE Breast cancer is the most frequent type of cancer among women (25% of all cancers). The angiogenic process that fuels the growth of tumors is a potential early indicator for differentiating between malignant and benign tumors. Recently, the use of microbubble-based contrast agents combined with ultrasound has allowed the development of contrast agent-specific imaging modes that provide visualization of tumor neovascularity. CONCLUSION Contrast-enhanced Doppler, harmonic, and subharmonic imaging are some of the imaging modes that have been investigated for visualizing and quantifying the vascularity in breast tumors.
Collapse
|
12
|
Delineation of atherosclerotic plaque using subharmonic imaging filtering techniques and a commercial intravascular ultrasound system. ULTRASONIC IMAGING 2013; 35:30-44. [PMID: 23287505 PMCID: PMC3683316 DOI: 10.1177/0161734612469511] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The ability to delineate atherosclerotic plaque from the surrounding tissue using custom-developed subharmonic imaging (SHI) digital filtering techniques was investigated in vivo using a commercially available system. Atherosclerosis was induced in the aorta of two Watanabe Heritable Hyperlipidemic rabbits following which injections of an ultrasound contrast agent (UCA) Definity (Lantheus Medical Imaging, N Billerica, Massachusetts) were administered. Imaging was performed using a Galaxy intravascular ultrasound (IVUS) scanner (Boston Scientific, Natick, Massachusetts) equipped with an Atlantis® SR Pro Imaging Catheter (Boston Scientific). Four preliminary band-pass filters were designed to isolate the subharmonic signal (from surrounding tissue) and applied to the radio-frequency (RF) data. Preliminary filter performances were compared in terms of vessel-tissue contrast-to-tissue ratio (CTR) and visual examination. Based on preliminary results, a subharmonic adaptive filter and a stopband (SB) filter were designed and applied to the RF data. Images were classified as fundamental, SHI, and SB. Four readers performed qualitative analysis of 168 randomly selected images (across all three imaging modes). The images were scored for overall image quality, image noise, plaque visualization, and vessel lumen visualization. A Wilcoxon signed-rank test was used to compare the scores followed by intraclass correlation (ICC) evaluation. Quantitative analysis was performed by calculating the CTRs for the vessel-to-plaque and vessel-to-tissue (compared using a paired student's t test). Qualitative analysis showed SHI and SB to have significantly less image noise relative to the fundamental mode (p < 0.001). Fundamental mode scored significantly higher than SHI and SB for the remaining three categories. ICC showed mixed results among reader evaluation for delineation of plaque. However, quantitatively, SHI produced the best vessel-plaque CTR.
Collapse
|
13
|
Investigating the efficacy of subharmonic aided pressure estimation for portal vein pressures and portal hypertension monitoring. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1784-98. [PMID: 22920550 PMCID: PMC3576693 DOI: 10.1016/j.ultrasmedbio.2012.06.013] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2012] [Revised: 06/19/2012] [Accepted: 06/29/2012] [Indexed: 05/14/2023]
Abstract
The efficacy of using subharmonic emissions from Sonazoid microbubbles (GE Healthcare, Oslo, Norway) to track portal vein pressures and pressure changes was investigated in 14 canines using either slow- or high-flow models of portal hypertension (PH). A modified Logiq 9 scanner (GE Healthcare, Milwaukee, WI, USA) operating in subharmonic mode (f(transmit): 2.5 MHz, f(receive): 1.25 MHz) was used to collect radiofrequency data at 10-40% incident acoustic power levels with 2-4 transmit cycles (in triplicate) before and after inducing PH. A pressure catheter (Millar Instruments, Inc., Houston, TX, USA) provided reference portal vein pressures. At optimum insonification, subharmonic signal amplitude changes correlated with portal vein pressure changes; r ranged from -0.82 to -0.94 and from -0.70 to -0.73 for PH models considered separately or together, respectively. The subharmonic signal amplitudes correlated with absolute portal vein pressures (r: -0.71 to -0.79). Statistically significant differences between subharmonic amplitudes, before and after inducing PH, were noted (p ≤ 0.01). Portal vein pressures estimated using subharmonic aided pressure estimation did not reveal significant differences (p > 0.05) with respect to the pressures obtained using the Millar pressure catheter. Subharmonic-aided pressure estimation may be useful clinically for portal vein pressure monitoring.
Collapse
|
14
|
Improving the sensitivity of high-frequency subharmonic imaging with coded excitation: a feasibility study. Med Phys 2012; 39:2049-60. [PMID: 22482626 PMCID: PMC3321054 DOI: 10.1118/1.3694101] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2011] [Revised: 02/23/2012] [Accepted: 02/23/2012] [Indexed: 12/18/2022] Open
Abstract
PURPOSE Subharmonic intravascular ultrasound imaging (S-IVUS) could visualize the adventitial vasa vasorum, but the high pressure threshold required to incite subharmonic behavior in an ultrasound contrast agent will compromise sensitivity-a trait that has hampered the clinical use of S-IVUS. The purpose of this study was to assess the feasibility of using coded-chirp excitations to improve the sensitivity and axial resolution of S-IVUS. METHODS The subharmonic response of Targestar-p(TM), a commercial microbubble ultrasound contrast agent (UCA), to coded-chirp (5%-20% fractional bandwidth) pulses and narrowband sine-burst (4% fractional bandwidth) pulses was assessed, first using computer simulations and then experimentally. Rectangular windowed excitation pulses with pulse durations ranging from 0.25 to 3 μs were used in all studies. All experimental studies were performed with a pair of transducers (20 MHz/10 MHz), both with diameter of 6.35 mm and focal length of 50 mm. The size distribution of the UCA was measured with a Casy(TM) Cell counter. RESULTS The simulation predicted a pressure threshold that was an order of magnitude higher than that determined experimentally. However, all other predictions were consistent with the experimental observations. It was predicted that: (1) exciting the agent with chirps would produce stronger subharmonic response relative to those produced by sine-bursts; (2) increasing the fractional bandwidth of coded-chirp excitation would increase the sensitivity of subharmonic imaging; and (3) coded-chirp would increase axial resolution. The experimental results revealed that subharmonic-to-fundamental ratios obtained with chirps were 5.7 dB higher than those produced with sine-bursts of similar duration. The axial resolution achieved with 20% fractional bandwidth chirps was approximately twice that achieved with 4% fractional bandwidth sine-bursts. CONCLUSIONS The coded-chirp method is a suitable excitation strategy for subharmonic IVUS imaging. At the 20 MHz transmission frequency and 20% fractional bandwidth, coded-chirp excitation appears to represent the ideal tradeoff between subharmonic strength and axial resolution.
Collapse
|
15
|
Parametric subharmonic imaging using a commercial intravascular ultrasound scanner: an in vivo feasibility study. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2012; 31:361-71. [PMID: 22368126 PMCID: PMC3576695 DOI: 10.7863/jum.2012.31.3.361] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
OBJECTIVES The feasibility of visualizing atherosclerotic plaque using parametric subharmonic intravascular ultrasound (IVUS) was investigated in vivo. METHODS Atherosclerosis was induced in the aorta of 2 rabbits. Following injection of Definity (Lantheus Medical Imaging, North Billerica, MA), radiofrequency IVUS signals were acquired at 40 MHz with a Galaxy IVUS scanner (Boston Scientific/Scimed, Natick, MA). Subharmonic imaging (SHI; receiving at 20 MHz) was performed offline by applying an 8-order equalization filter. Contrast-to-tissue ratios (CTRs) were computed for the vessel relative to the plaque area over 4 time points. Contrast-to-tissue ratios were also calculated for the plaque-tissue and vessel-tissue from 4 tissue regions of interest at 4 time points. Finally, parametric images showing the cumulative maximum intensity (CMI), time to peak, perfusion (PER), and time-integrated intensity (TII) were generated for the fundamental and subharmonic data sets, and CTR measurements were repeated. RESULTS Injection of the contrast agent resulted in improved delineation between plaque and the vessel lumen. Subharmonic imaging resulted in noticeable tissue suppression, although the intensity from the contrast agent was reduced. No significant improvement in the plaque to vessel lumen CTR was observed between the subharmonic and fundamental IVUS (2.1 ± 3.64 versus 2.2 ± 4.20; P = .5). However, the CTR for plaque-tissue was improved (11.8 ± 7.32 versus 9.9 ± 7.06; P < .0001) for SHI relative to fundamental imaging. Cumulative-maximum-intensity and TII maps of both fundamental and subharmonic data provided increased CTRs relative to nonparametric data sets (P < .002). Additionally, the CMI, PER, and TII of SHI IVUS showed significantly improved vessel-plaque CTRs for SHI relative to the fundamental (P < .04). CONCLUSIONS Parametric SHI IVUS of atherosclerotic plaque is feasible and improves the visualization of the plaque.
Collapse
|
16
|
Simultaneous grayscale and subharmonic ultrasound imaging on a modified commercial scanner. ULTRASONICS 2011; 51:890-7. [PMID: 21621239 PMCID: PMC3222296 DOI: 10.1016/j.ultras.2011.05.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2011] [Revised: 04/28/2011] [Accepted: 05/03/2011] [Indexed: 05/03/2023]
Abstract
OBJECTIVE To demonstrate the feasibility of simultaneous dual fundamental grayscale and subharmonic imaging on a modified commercial scanner. MOTIVATION The ability to generate signals at half the insonation frequency is exclusive to ultrasound contrast agents (UCA). Thus, subharmonic imaging (SHI; transmitting at f(0) and receiving at f(0)/2) provides improved visualization of UCA within the vasculature via suppression of the surrounding tissue echoes. While this capability has proven useful in a variety of clinical applications, the SHI suppression of surrounding tissue landmarks (which are needed for sonographic navigation) also limits it use as a primary imaging modality. In this paper we present results using a commercial ultrasound scanner modified to allow imaging in both grayscale (f(0)=4.0 MHz) and SHI (f(0)=2.5 MHz, f(0)/2=1.25 MHz) modes in real time. METHODS A Logiq 9 ultrasound scanner (GE Healthcare, Milwaukee, WI) with a 4C curvilinear probe was modified to provide this capability. Four commercially available UCA (Definity, Lantheus Medical Imaging, North Billerica, MA; Optison, GE Healthcare, Princeton, NJ; SonoVue, Bracco Imaging, Milan, Italy; and Sonazoid, GE Healthcare, Oslo, Norway) were all investigated in vitro over an acoustic output range of 3.34 MPa. In vivo the subharmonic response of Sonazoid was investigated in the portal veins of four canines (open abdominal cavity) and four patients with suspected portal hypertension. RESULTS In vitro, the four UCA showed an average maximum subharmonic amplitude of 44.1±5.4 dB above the noise floor with a maximum subharmonic amplitude of 48.6±1.6 dB provided by Sonazoid. The average in vivo maximum signal above the noise floor from Sonazoid was 20.8±2.3 dB in canines and 33.9±5.2 dB in humans. Subharmonic amplitude as a function of acoustic output in both groups matched the S-curve behavior of the agent observed in vitro. The dual grayscale imaging provided easier sonographic navigation, while the degree of tissue suppression in SHI mode varied greatly on a case by case basis. CONCLUSIONS These results demonstrate the feasibility of dual grayscale and SHI on a modified commercial scanner. The ability to simultaneously visualize both imaging modes in real time should improve the applicability of SHI as a future primary clinical imaging modality.
Collapse
|
17
|
Parametric imaging using subharmonic signals from ultrasound contrast agents in patients with breast lesions. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2011; 30:85-92. [PMID: 21193708 PMCID: PMC6053048 DOI: 10.7863/jum.2011.30.1.85] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Parametric maps showing perfusion of contrast media can be useful tools for characterizing lesions in breast tissue. In this study we show the feasibility of parametric subharmonic imaging (SHI), which allows imaging of a vascular marker (the ultrasound contrast agent) while providing near complete tissue suppression. Digital SHI clips of 16 breast lesions from 14 women were acquired. Patients were scanned using a modified LOGIQ 9 scanner (GE Healthcare, Waukesha, WI) transmitting/receiving at 4.4/2.2 MHz. Using motion-compensated cumulative maximum intensity (CMI) sequences, parametric maps were generated for each lesion showing the time to peak (TTP), estimated perfusion (EP), and area under the time-intensity curve (AUC). Findings were grouped and compared according to biopsy results as benign lesions (n = 12, including 5 fibroadenomas and 3 cysts) and carcinomas (n = 4). For each lesion CMI, TTP, EP, and AUC parametric images were generated. No significant variations were detected with CMI (P = .80), TTP (P = .35), or AUC (P = .65). A statistically significant variation was detected for the average pixel EP (P = .002). Especially, differences were seen between carcinoma and benign lesions (mean ± SD, 0.10 ± 0.03 versus 0.05 ± 0.02 intensity units [IU]/s; P = .0014) and between carcinoma and fibroadenoma (0.10 ± 0.03 versus 0.04 ± 0.01 IU/s; P = .0044), whereas differences between carcinomas and cysts were found to be nonsignificant. In conclusion, a parametric imaging method for characterization of breast lesions using the high contrast to tissue signal provided by SHI has been developed. While the preliminary sample size was limited, results show potential for breast lesion characterization based on perfusion flow parameters.
Collapse
|