1
|
Extramiana F, Dubois R, Vaglio M, Roussel P, Dreyfus G, Badilini F, Leenhardt A, Maison-Blanche P. The time course of new T-wave ECG descriptors following single- and double-dose administration of sotalol in healthy subjects. Ann Noninvasive Electrocardiol 2010; 15:26-35. [PMID: 20146779 PMCID: PMC6932454 DOI: 10.1111/j.1542-474x.2009.00336.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
INTRODUCTION The aim of the study was to assess the time course effect of IKr blockade on ECG biomarkers of ventricular repolarization and to evaluate the accuracy of a fully automatic approach for QT duration evaluation. METHODS Twelve-lead digital ECG Holter was recorded in 38 healthy subjects (27 males, mean age = 27.4 + or - 8.0 years) on baseline conditions (day 0) and after administration of 160 mg (day 1) and 320 mg (day 2) of d-l sotalol. For each 24-hour period and each subject, ECGs were extracted every 10 minutes during the 4-hour period following drug dosage. Ventricular repolarization was characterized using three biomarker categories: conventional ECG time intervals, principal component analysis (PCA) analysis on the T wave, and fully automatic biomarkers computed from a mathematical model of the T wave. RESULTS QT interval was significantly prolonged starting 1 hour 20 minutes after drug dosing with 160 mg and 1 hour 10 minutes after drug dosing with 320 mg. PCA ventricular repolarization parameters sotalol-induced changes were delayed (>3 hours). After sotalol dosing, the early phase of the T wave changed earlier than the late phase prolongation. Globally, the modeled surrogate QT paralleled manual QT changes. The duration of manual QT and automatic surrogate QT were strongly correlated (R(2) = 0.92, P < 0.001). The Bland and Altman plot revealed a nonstationary systematic bias (bias = 26.5 ms + or - 1.96*SD = 16 ms). CONCLUSIONS Changes in different ECG biomarkers of ventricular repolarization display different kinetics after administration of a potent potassium channel blocker. These differences need to be taken into account when designing ventricular repolarization ECG studies.
Collapse
Affiliation(s)
- Fabrice Extramiana
- Lariboisière Hospital, APHP, Paris 7 University, INSERM U942, Paris, France.
| | | | | | | | | | | | | | | |
Collapse
|
2
|
Häggmark S, Haney MF, Johansson G, Reiz S, Näslund U. Contributions of myocardial ischemia and heart rate to ST segment changes in patients with or without coronary artery disease. Acta Anaesthesiol Scand 2008; 52:219-28. [PMID: 17999710 DOI: 10.1111/j.1399-6576.2007.01507.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND ST changes related to ischemia at different heart rates (HRs) have not been well described. We aimed to analyze ST dynamic changes by vectorcardiography (VCG) during pacing-induced HR changes for subjects with proven coronary artery disease (CAD) and without (non-CAD). METHODS Symptomatic CAD patients scheduled for elective surgery were enrolled along with a non-CAD group. During anesthesia, both groups were placed at multiple ascending levels. VCG ST data, and in particular in ST change vector magnitude (STC-VM) from baseline, along with arterial and great coronary artery vein (GCV) blood samples were collected to determine regional myocardial lactate production. RESULTS A total of 35 CAD and 10 non-CAD patients were studied over six incremental 10 beat/min HR increases. STC-VM mean levels increased in the CAD group from 9+/-5 to 131+/-37 microV (standard deviation) compared with non-CAD subjects with 8+/-3-76+/-34 microV. Myocardial ischemia (lactate production) was noted at higher HRs and the positive predictive value for STC-VM to detect ischemia was 58% with the negative predictive value being 88%. STC-VM at 54 microV showed a sensitivity of 88% and a specificity of 75% for identification of ischemia. CONCLUSIONS Both HR and ischemia at higher HRs contribute to VCG ST elevation. Established ST ischemia detection concerning HR levels is suboptimal, and further attention to the effects of HR on ST segments is needed to improve electrocardiographic ischemia criteria.
Collapse
Affiliation(s)
- S Häggmark
- Heart Centre, University Hospital, Umeå, Sweden.
| | | | | | | | | |
Collapse
|
3
|
Eriksson M, Hofman-Bang C, Persson H, Tornvall P. Limited prognostic value of noninvasive assessment of reperfusion by continuous vectorcardiography in an unselected cohort of patients with acute ST-elevation myocardial infarction treated with thrombolysis. J Electrocardiol 2007; 40:305-10. [PMID: 17292384 DOI: 10.1016/j.jelectrocard.2006.12.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2006] [Accepted: 12/14/2006] [Indexed: 11/29/2022]
Abstract
AIMS We studied the prognostic value of different reperfusion criteria of short-term continuous vectorcardiography (VCG) in an unselected cohort of 400 patients with ST-elevation myocardial infarction, treated at 4 coronary care units in Stockholm, Sweden, between 1999 and 2002. The main outcome measure was 1-year mortality. RESULTS Of 400 study patients, 41 (10.2%) died within 1 year. One-year mortality in patients without reperfusion at 90 minutes, defined as ST resolution below 50% on VCG, was 11.6% compared with 9.0% in patients with reperfusion, (P = 0.4). Ninety-eight (24.5%) patients underwent intervention before discharge and percutaneous coronary intervention or coronary artery bypass grafting or both during the index admission. Percutaneous coronary intervention or coronary artery bypass grafting was related to improved 1-year survival (97 +/- 2% vs 87 +/- 2%, P = .0076). ST-vector magnitude resolution at 90 minutes was lower in patients who underwent intervention (P = .045). None of the reperfusion criteria of VCG was significantly associated with 1-year mortality. CONCLUSION Our results show that noninvasive assessment of reperfusion by continuous VCG has limited prognostic value in unselected patients treated with thrombolysis because of ST-elevation myocardial infarction when subsequent revascularizations are performed. However, VCG might be useful in selecting patients for coronary angiography with subsequent revascularization.
Collapse
Affiliation(s)
- Michael Eriksson
- Department of Cardiology, Karolinska University Hospital, Karolinska Institute, Stockholm, Sweden.
| | | | | | | |
Collapse
|
4
|
Dilaveris P, Anastasopoulos A, Androulakis A, Theoharis A, Zumerle B, Tzannetis G, Kallikazaros I, Stefanadis C. Effects of thrombolysis on vectorcardiographic indices of ventricular repolarization: correlation with ST-segment resolution. J Electrocardiol 2005; 38:347-53. [PMID: 16216611 DOI: 10.1016/j.jelectrocard.2005.04.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2004] [Revised: 03/29/2005] [Accepted: 04/21/2005] [Indexed: 11/24/2022]
Abstract
To investigate the effects of thrombolysis on vectorcardiographic (VCG) descriptors of ventricular repolarization in association with ST-segment resolution, 70 consecutively recruited patients with acute myocardial infarction underwent digital 12-lead electrocardiograms (ECGs) before and at 3 hours after thrombolysis. The alterations in the VCG descriptors spatial T amplitude and spatial QRS-T angle from the pre- to the post-thrombolysis ECG, as well as the ST-segment resolution, were calculated. Angiography revealed patency of the infarct-related coronary artery after thrombolysis in 52 (74%) patients (group A) and occlusion in 18 (26%) (group B). The spatial T amplitude was highly significantly reduced after thrombolysis in group A (P<.0001), but only marginally reduced in group B (P=.016). The spatial QRS-T angle was also significantly, although only marginally, reduced after thrombolysis in group A (P=.019), whereas it was not changed after thrombolysis in group B (P=.868). An ST-segment resolution of 60% and a 25% reduction in the spatial T amplitude after thrombolysis were able to identify patency of the infarct-related coronary artery with sensitivities of 90% and 77% and specificities of 94% and 74%, respectively. Both VCG descriptors were significantly affected by thrombolysis in patients with acute myocardial infarction, but constituted only moderate markers of thrombolysis efficacy, as evidenced by the presence of patency in the infarct-related coronary artery, compared with the ST-segment resolution.
Collapse
Affiliation(s)
- Polychronis Dilaveris
- 1st University Department of Cardiology, Hippokration Hospital, 115 27 Athens, Greece.
| | | | | | | | | | | | | | | |
Collapse
|
5
|
Singh PN, Athar MS. Simplified [correction of Simlified] calculation of mean QRS vector (mean electrical axis of heart) of electrocardiogram. Indian J Physiol Pharmacol 2003; 47:212-6. [PMID: 15255627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 04/30/2023]
Abstract
In clinical practice assessment of the mean QRS axis (MQRSA) provides information related either with hypertrophy of the ventricles or conduction blocks. The method adopted by clinicians i.e. the inspection of the QRS voltage in six of the limb leads has inherent element of subjectivity of approximately 10degrees. Moreover, in certain condition, when there is ambiguity about differentiation of left axis deviation assessed by inspection method in to either hypertrophy of left ventricles or complete/hemi block of the left bundle branches, accurate measurement of the axis becomes necessary to arrive at the correct diagnosis. Though a formula based on area under R wave and S-wave of the same QRS complex has been derived for accurate measurement of axis, considering its use in the computer software, working with ordinary electrocardiograph the only method for accurate measurement of the QRS axis is plotting method i. e. the net voltages in Lead-I, and III on their respective axes which is not practicable in clinical settings. Although, calculation of MQRSA by area method gives an accurate assessment of MQRSA, some authors prefer measurement of axis by voltage method, as in cases of the right ventricular hypertrophy with a broad S-wave calculation of axis by area method may give erroneous results. Hence, to obtain correct measurement of MQRSA, we have derived a simplified formula based on the net voltage of QRS complexes in Lead-I and Lead-III. The formula derived is as follows, Tan(theta) =(I + 2III) divided by sqrt [3I], where I and III represent net voltage in Lead-I and III, theta = angle subtended with the axis Lead-I. The value of theta can be found by using scientific calculator or the table. In case net voltage of QRS complex in Lead-I being negative, the value of the theta should be subtracted from 180degrees to find the angle of mean QRS vector.
Collapse
Affiliation(s)
- P N Singh
- Department of Physiology, Faculty of Medicine, A.M.U. Aligarh
| | | |
Collapse
|
6
|
Abstract
BACKGROUND Although the circulatory effects of cigarette smoking have been studied extensively, its impact on ventricular repolarization has not been adequately evaluated. METHODS The goal of our study was to determine whether cigarette smoking influences the spatial and temporal heterogeneity of ventricular repolarization in a population of young, healthy, male subjects. A digital 12-lead surface electrocardiogram was obtained from 1394 men recruited from the Hellenic Air Force and classified as smokers and nonsmokers. The maximum, minimum, and median QT intervals, QT dispersion (QT maximum - QT minimum), the rate-corrected maximum and median QT intervals, the slopes of the QT maximum/RR and QT median/RR regression equations, and the vectorcardiographic markers spatial T amplitude and spatial QRS-T angle were evaluated in the 2 groups. RESULTS Heart rate was significantly higher (P <.001) in smokers (n =691) compared with nonsmokers (n = 703). QT maximum, QT minimum, and QT median were significantly lower (P <.001), whereas the rate-corrected QT maximum (P =.04) and QT median (P =.06) were marginally higher in smokers than in nonsmokers. The spatial T amplitude was lower (P =.002), whereas the spatial QRS-T angle was higher (P =.01) in smokers compared with nonsmokers. Neither QT dispersion nor the slopes of the QT/RR and the spatial descriptors/RR regression equations differed between smokers and nonsmokers. CONCLUSIONS Ventricular repolarization is altered in young male cigarette smokers. The differences in the heterogeneity of ventricular repolarization between smokers and nonsmokers are mainly due to heart rate differences between the 2 study groups.
Collapse
Affiliation(s)
- P Dilaveris
- State Department of Cardiology, Hippokration Hospital, Athens, Greece.
| | | | | | | | | |
Collapse
|
7
|
Eriksson P, Gunnarsson G, Dellborg M. Diagnosis of acute myocardial infarction in patients with chronic left bundle-branch block. Standard 12-lead ECG compared to dynamic vectorcardiography. SCAND CARDIOVASC J 1999; 33:17-22. [PMID: 10093854 DOI: 10.1080/14017439950141984] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Standard 12-lead electrocardiogram (ECG) criteria were evaluated and compared with dynamic vectorcardiography for diagnosing acute myocardial infarction in 33 patients with chronic left bundle-branch block. In 14 patients a clinical diagnosis of acute myocardial infarction was made, but it was found that none of the seven most promising ECG criteria suggested in the literature could alone or in combination diagnose acute myocardial infarction. QRS vector difference evolution showed the same kind of pattern as that for patients with narrow QRS-complex. By using a predefined specific pattern, a diagnostic accuracy of 79% was achieved. The results indicate that dynamic vectorcardiography is a better tool for diagnosing and monitoring acute myocardial infarction in patients with left bundle-branch block than standard 12-lead ECGs taken on admission and after 12-24 h.
Collapse
Affiliation(s)
- P Eriksson
- Department of Medicine, Sahlgrenska University Hospital/Ostra, Göteborg, Sweden
| | | | | |
Collapse
|
8
|
Badir BF, LeBlanc AR, Nasmith JB, Palisaitis D, Dubé B, Nadeau R. Continuous ST-segment monitoring during coronary angioplasty using orthogonal ECG leads. J Electrocardiol 1997; 30:175-87. [PMID: 9261725 DOI: 10.1016/s0022-0736(97)80002-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
In order to characterize ST-segment shifts during transient coronary artery occlusion, 24 patients with single-vessel disease were continuously monitored during percutaneous transluminal coronary angioplasty by use of a computerized orthogonal lead system. Changes of ST-segment (J + 60 ms) in leads X, Y, and Z and of the ST vector magnitude were analyzed by using 20 microV as a threshold for significant ST-segment shift. The sensitivity and magnitude of this shift were compared among the left anterior descending, right coronary, and circumflex artery groups (11, 8, and 5 patients, respectively) during balloon inflation. Significant ST-segment shifts were seen in 22 patients (92%) in ST-VM, Y, and Z leads and all patients in lead X (100%). There was no significant difference in sensitivity of either the ST vector magnitude or the most sensitive lead for occlusion detection among the three groups. There was a significantly greater magnitude of ST shift during left anterior descending artery occlusion than during right coronary artery and circumflex artery occlusions in ST-VM. Analysis of the direction of ST shifts in the X, Y, and Z leads showed a characteristic pattern, which could distinguish among the three coronary groups in 21 patients (88%). The presence of collaterals was significantly associated with ST-segment depression in leads oriented toward ischemia (3 of 6 patients) as compared with ST-segment elevation in the absence of collaterals (all of 15 patients), P > .01. It is concluded that ST-segment shift in the orthogonal leads is a reliable marker for myocardial ischemia. It is equally sensitive to occlusion of each of the three major coronary arteries and can thus identify the occluded coronary. An ST-segment depression instead of an elevation was related to the presence of collaterals, which may reflect a lesser degree of ischemia.
Collapse
MESH Headings
- Adult
- Aged
- Analysis of Variance
- Angioplasty, Balloon, Coronary/instrumentation
- Angioplasty, Balloon, Coronary/methods
- Angioplasty, Balloon, Coronary/statistics & numerical data
- Collateral Circulation
- Coronary Disease/physiopathology
- Female
- Humans
- Male
- Middle Aged
- Monitoring, Intraoperative/instrumentation
- Monitoring, Intraoperative/methods
- Monitoring, Intraoperative/statistics & numerical data
- Myocardial Infarction/physiopathology
- Sensitivity and Specificity
- Signal Processing, Computer-Assisted
- Vectorcardiography/instrumentation
- Vectorcardiography/methods
- Vectorcardiography/statistics & numerical data
Collapse
Affiliation(s)
- B F Badir
- Research Centre, Hôpital du Sacré-Coeur de Montréal, Québec, Canada
| | | | | | | | | | | |
Collapse
|
9
|
Affiliation(s)
- H Lei
- Institute of Biomedical Engineering, Xian Jiaotong University
| | | | | | | |
Collapse
|
10
|
Abstract
AIMS In this study we evaluated the prognostic value of three methods of early risk estimation in patients with unstable coronary disease. METHODS AND RESULTS The methods evaluated were: clinical risk estimation at hospital admission, continuous ST analysis with computerized vectorcardiography for 24 h and serial measurements of creatinine kinase-MB for 48 h. Twenty-seven (14%) of the 195 patients died or had a non-fatal infarction within one year. Clinical risk evaluation correctly identified a subgroup of patients with low risk but did not otherwise predict outcome. Fifty-six (29%) patients had ST vector magnitude episodes on vectorcardiography, 70 (38%) had three or more episodes of ST change vector magnitude and 74 (38%) had a peak creatinine kinase-MB value of 6 microgram.l-1 or more. The even rate for patients with ST vector magnitude episodes (23%) was significantly higher than for those without (10%; P < 0.05). For patients with and without three or more episodes of ST change vector magnitude the event rate was 23% and 9% respectively (P < 0.05) and for patients with and without creatinine kinase-MB > or = 6 microgram.l-1 the event rate was 23% and 8% respectively (P < 0.01). The positive predictive value of having none, either one or both of the ST or creatinine kinase-MB markers positive was incremental. CONCLUSION Continuous vectorcardiographic monitoring of ischaemia in combination with serial creatinine kinase-MB measurement considerably improves risk stratification in unstable coronary disease.
Collapse
Affiliation(s)
- K Andersen
- Department of Medicine, Ostra University Hospital, Göteborg, Sweden
| | | | | |
Collapse
|
11
|
Zhao Y, Yao A, Xu Y, Hao W, Tu J. [Analysis of vectorcardiogram (VCG) in 150 healthy pilots]. Space Med Med Eng (Beijing) 1997; 10:108-10. [PMID: 11539899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
Abstract
150 healthy male pilots, aged 22-46 years (31 +/- 5) were examined with the HBD-II A instrument. The results showed that vectorcardiogram (VCG) parameters of pilots were within the normal value by clinical diagnosis standard of VCG, but some indexes of VCG appeared different from the normal people, these might be the characteristics of VCG of pilots. The present study provided some new parameters of VCG such as P loop. The results of this study may be used for pilots selection and real-time medical monitoring for pilots on ground training.
Collapse
Affiliation(s)
- Y Zhao
- Institute of Space Medico-Engineering, Beijing, China
| | | | | | | | | |
Collapse
|
12
|
Abstract
BACKGROUND Analysis of the surface ECG can predict the locations of pacing foci but is of limited value for locating arrhythmogenic substrates causing ventricular tachycardia because of the effects of myocardial infarction, ischaemia, and bundle branch block on ventricular activation. AIM To determine whether analysis of the initial 60 ms segment of the surface QRS improves the accuracy of the ECG for predicting ventricular tachycardia origin we correlated the locations of 37 arrhythmogenic areas present in 20 patients with the 3D vectors of the ventricular tachycardias generated by each respective area. METHODS The 3D vector of each ventricular tachycardia morphology was calculated from the integrals of the initial 60 ms of the surface vectorcardiogram and from the entire QRS recorded in each lead of the Frank orthogonal lead vectorcardiogram. Sixty eight-morphologies of ventricular tachycardia were mapped using simultaneous recordings from 60 catheter electrodes. RESULTS Ventricular tachycardias with 3D vectors directed inferiorly and posteriorly or superiorly and anteriorly were more likely to originate from the septum, P = 0.04, whereas tachycardias directed superiorly and to the right were more likely to originate from the inferior wall and the cardiac apex, P = 0.001. However, the same arrhythmogenic area could generate multiple ventricular tachycardias with different 3D vectors. In addition, ventricular tachycardias with similar 3D vectors were generated by arrhythmogenic areas in the septal, apical and inferior walls. The variances of the mean 3D vectors of ventricular tachycardias originating from each of 12 different cardiac regions were no different when based on the initial 60 ms of the surface QRS than on the entire surface QRS. CONCLUSION Analysis of the surface ECG provides only an approximate guide to the locations of arrhythmogenic areas generating ventricular tachycardia even when analysis is restricted to the initial forces in the surface QRS. Therefore, detailed mapping is needed to accurately determine the number and location of arrhythmogenic areas.
Collapse
Affiliation(s)
- L M Davis
- Cardiology Department, Westmead Hospital, New South Wales, Australia
| | | | | | | |
Collapse
|
13
|
Troquet J. [Vectorcardiographic significance of three-dimensional devices ended and nevertheless without boundaries]. Arch Int Physiol Biochim 1988; 96:127-36. [PMID: 2460057 DOI: 10.3109/13813458809079634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The circular boundary of a disk may be suppressed by connecting it to that of an other disk presenting the same characteristics (isomorph). In such a condition, energizing the first element indirectly feeds the second one by the same amount than it would be delivered to infinite surroundings. In mathematical terms, this means that summing up the potentials arising at the same points of the two connected disks leads to the potential identically located in the disk activated as before but disconnected from its isomorph: the statement being true except for a constant. In three dimensions, the problem is somewhat more difficult because a single isomorph cannot drain all the current that would be transmitted by a sphere to the infinite medium in which it is immersed. So, connecting two spheres results in a partial confinement which, however, does not rule out the aforementioned statement. On the other hand, the potential differences around the isomorph centre are well-suited to a vectorcardiographic use like Rijlant's one; this method is consequently justified as to its principle. Finally, we have studied the radial alinearity which is introduced by Rijlant to improve his instrument. We have shown the changes related to Rijlant's way of building his network and we conclude that the use of many equivalent layers bears on grounds similar to that which are developed for the linear isomorphs.
Collapse
Affiliation(s)
- J Troquet
- Institut Léon Frederiq, Physiologie, Université de Liège
| |
Collapse
|
14
|
Abel H. [Possibilities of the orthogonal electro- and vectorcardiography]. Z Gesamte Inn Med 1966; 21:103-6. [PMID: 5983066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
15
|
Schubert E. [Modern fundamentals of electrocardiographic methods of investigation]. Z Gesamte Inn Med 1966; 21:101-3. [PMID: 5983065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|