1
|
Qu K, Morioka K, Nakamura K, Yamamoto S, Hemmi A, Shoji A, Nakajima H. Development of a C-reactive protein quantification method based on flow rate measurement of an ink solution pushed out by oxygen gas generated by catalase reaction. Mikrochim Acta 2023; 191:24. [PMID: 38091091 DOI: 10.1007/s00604-023-06108-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Accepted: 11/19/2023] [Indexed: 12/18/2023]
Abstract
A novel determination method for protein biomarkers based on on-chip flow rate measurement was developed using a microchip with organic photodiodes (OPDs). This quantitative method is based on the flow rate measurement of an ink solution pushed out by oxygen gas generated through catalase reaction. The amount of oxygen gas generated in the sample reservoir is dependent on the concentration of the analyte; therefore, the flow rate of the ink solution is also dependent on the concentration of the analyte. The concentration of the analyte can thus be estimated by measurement of the ink solution flow rate. The ink solution flow rate was estimated by measuring the migration time of the ink solution between two points using two OPDs placed below the microchannel. The principle of this method was demonstrated by the measurement of catalase using the microchip. In addition, the developed method was applied to the determination of C-reactive protein (CRP), a biomarker of inflammation, based on a catalase-linked immunosorbent assay (C-LISA). The limit of detection for CRP was 0.20 µg/mL. The method was also applied to the determination of CRP in human serum, and the quantitative values obtained by this method were in excellent agreement with those obtained by the conventional enzyme-linked immunosorbent assay (ELISA) method. The developed method does not require a photodetector with high sensitivity and is thus capable of downsizing; therefore, this will be useful for on-site analyses such as point-of-care testing and field measurements.
Collapse
|
2
|
Kagawa M, Morioka K, Osashima M, Hemmi A, Yamamoto S, Shoji A, Uchiyama K, Nakajima H. Development of small-sized fluorescence detector for pipette tip-based biosensor for on-site diagnosis. Talanta 2023; 256:124311. [PMID: 36738624 DOI: 10.1016/j.talanta.2023.124311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 01/19/2023] [Accepted: 01/26/2023] [Indexed: 02/05/2023]
Abstract
A small-sized fluorescence detector (referred to as a pipette tip [PT]-reader) was developed for a pipette tip-based biosensor. The PT-reader allows us to measure the fluorescence intensity of a solution in a truncated cone-shaped pipette tip with only the tip inserted into the PT-reader. A pipette holder made from a mixture of polydimethylsiloxane (PDMS) and carbon black was capable of the rigorous position arrangement of a truncated cone shaped-pipette tip and the prevention of stray light. The detection performance of the PT-reader was evaluated by measurement of resorufin. The limit of detection (LOD; 3σ) and the relative standard deviation (RSD, n = 4) were estimated to be 0.46 μM and 0.47-4.1%, respectively. This performance was comparable to that of a desktop-type fluorescence microplate reader. In addition, the PT-reader was applied to the quantification of immunoglobulin A (IgA), and the LOD (3σ) of IgA was estimated to be 1.0 ng/mL. The quantitation values of IgA in human saliva obtained by the PT-based enzyme-linked immunosorbent assay (PT-ELISA) were in agreement with those obtained by conventional ELISA. The PT-reader is expected to be useful for low-cost and user-friendly measurements, and the technique of device development proposed in this study will contribute to the progress of on-site medical diagnosis.
Collapse
|
3
|
Murakami H, Iida K, Oda Y, Umemura T, Nakajima H, Esaka Y, Inoue Y, Teshima N. Hydrophilic interaction chromatography-type sorbent prepared by the modification of methacrylate-base resin with polyethyleneimine for solid-phase extraction of polar compounds. ANAL SCI 2023; 39:375-381. [PMID: 36577893 DOI: 10.1007/s44211-022-00250-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 12/14/2022] [Indexed: 12/29/2022]
Abstract
Hydrophilic interaction chromatography (HILIC)-type sorbents were newly developed for the solid-phase extraction (SPE) of polar compounds. Two methacrylate-base resins with different cross-linking monomers and pore properties were synthesized, and three polyethyleneimines (PEIs) with different molecular weights were modified onto each base resin. In both cases, PEIs with a molecular weight of 10,000 (PEI-10,000) exhibited the highest adsorption properties for polar compounds (uracil, uridine, adenosine, cytidine, and guanosine). To control the water-enriched layer at the surface of the PEI-10,000-modified sorbents, the additive amount of PEI-10,000 in the modified reaction was also optimized. When 10 times the amount of PEI-10,000 to each base resin was added, an improvement in adsorption property was observed. Moreover, the use of a nonaqueous sample solution (100% acetonitrile) during the sample loading process drastically improved adsorption, especially for uracil (about 80%) and adenosine (100%). These results indicate that the formation of a strong water-enriched layer at the surface of sorbents with an effective expression of hydrophilic interaction was an important factor in the adsorption properties of polar compounds in HILIC mode-SPE.
Collapse
|
4
|
Lin H, Kasai N, Xu N, Nakajima H, Kato S, Zeng H, Lin JM, Mao S, Uchiyama K. Localized hydrodynamic flow confinement assisted nanowire sensor for ultrasensitive protein detection. Biosens Bioelectron 2022; 218:114788. [DOI: 10.1016/j.bios.2022.114788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 09/27/2022] [Accepted: 10/03/2022] [Indexed: 11/02/2022]
|
5
|
Si S, Kaneko T, Xu L, Luo H, Nakajima H, Kasai N, Uchiyama K, Wu D, Zeng H. Microsphere amplified fluorescence and its application in sensing. Biosens Bioelectron 2022; 218:114791. [DOI: 10.1016/j.bios.2022.114791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 09/25/2022] [Accepted: 10/06/2022] [Indexed: 11/25/2022]
|
6
|
Sakuma R, Nagai Y, Nakajima H, Lin KT, Kajihara Y. Passive dual-probe near-field microscopy. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:113708. [PMID: 36461468 DOI: 10.1063/5.0116419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Accepted: 10/27/2022] [Indexed: 06/17/2023]
Abstract
Accurate and simultaneous multiposition near-field measurements are essential to study the time-dependent local dynamics, including heat and carrier transfer. The existing passive long-wavelength infrared (LWIR) scattering-type scanning near-field optical microscopy (s-SNOM) systems with a single probe cannot perform precise near-field measurements of the heat or carrier transporting process at the nanoscale level. Therefore, in this study, we developed a passive LWIR s-SNOM system with two probes. To test the effectiveness of the proposed passive LWIR dual-probe s-SNOM system, each probe was precisely controlled using a shear-force feedback system, and the mechanical interference between the probes was used to monitor the distance between the probes. We achieved simultaneous near-field measurements at two different positions 500 nm apart using the proposed passive LWIR dual-probe s-SNOM system. The simultaneously detected near-field signals from two different points were extracted individually, making this technique an effective nanoscale analysis tool for local carrier dynamics.
Collapse
|
7
|
Kagawa Y, Kotani D, Bando H, Takahashi N, Horita Y, Kanazawa A, Kato T, Ando K, Satake H, Shinozaki E, Sunakawa Y, Takashima A, Yamazaki K, Yuki S, Nakajima H, Nakamura Y, Wakabayashi M, Taniguchi H, Ohta T, Yoshino T. PD-13 Plasma RAS dynamics and efficacy of anti-EGFR rechallenge in patients with RAS/BRAF wild-type metastatic colorectal cancer: REMARRY and PURSUIT trials. Ann Oncol 2022. [DOI: 10.1016/j.annonc.2022.04.091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
8
|
Mao S, Hu X, Tanaka Y, Zhou L, Peng C, Kasai N, Nakajima H, Kato S, Uchiyama K. A chemo-mechanical switchable valve on microfluidic chip based on a thermally responsive block copolymer. CHINESE CHEM LETT 2022. [DOI: 10.1016/j.cclet.2021.09.065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
9
|
Umemura T, Hatano T, Ogura T, Miyata T, Agawa Y, Nakajima H, Tomoyose R, Sakamoto H, Tsujimoto Y, Nakazawa Y, Wakabayashi T, Hashimoto T, Fujiki R, Shiraishi W, Nagata I. ADC Level is Related to DWI Reversal in Patients Undergoing Mechanical Thrombectomy: A Retrospective Cohort Study. AJNR Am J Neuroradiol 2022; 43:893-898. [PMID: 35550283 DOI: 10.3174/ajnr.a7510] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 03/17/2022] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE In patients with ischemic stroke, DWI lesions can occasionally be reversed by reperfusion therapy. This study aimed to ascertain the relationship between ADC levels and DWI reversal in patients with acute ischemic stroke who underwent recanalization treatment. MATERIALS AND METHODS We conducted a retrospective cohort study in patients with acute ischemic stroke who underwent endovascular mechanical thrombectomy with successful recanalization between April 2017 and March 2021. DWI reversal was assessed through follow-up MR imaging approximately 24 hours after treatment. RESULTS In total, 118 patients were included. DWI reversal was confirmed in 42 patients. The ADC level in patients with reversal was significantly higher than that in patients without reversal. Eighty-three percent of patients with DWI reversal areas had mean ADC levels of ≥520 × 10-6 mm2/s, and 71% of patients without DWI reversal areas had mean ADC levels of <520 × 10-6 mm2/s. The mean ADC threshold was 520 × 10-6 mm2/s with a sensitivity and specificity of 71% and 83%, respectively. In multivariate analysis, the mean ADC level (OR, 1.023; 95% CI, 1.013-1.033; P < .0001) was independently associated with DWI reversal. Patients with DWI reversal areas had earlier neurologic improvement (NIHSS at 7 days) than patients without reversal areas (P < .0001). CONCLUSIONS In acute ischemic stroke, the ADC value is independently associated with DWI reversal. Lesions with a mean ADC of ≥520 × 10-6 mm2/s are salvageable by mechanical thrombectomy, and DWI reversal areas regain neurologic function. The ADC value is easily assessed and is a useful tool to predict viable lesions.
Collapse
|
10
|
Shoji A, Nakajima M, Morioka K, Fujimori E, Umemura T, Yanagida A, Hemmi A, Uchiyama K, Nakajima H. Development of a surface plasmon resonance sensor using an optical fiber prepared by electroless displacement gold plating and its application to immunoassay. Talanta 2022; 240:123162. [PMID: 34996015 DOI: 10.1016/j.talanta.2021.123162] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/17/2021] [Accepted: 12/20/2021] [Indexed: 11/27/2022]
Abstract
A simple and low-cost method of fabricating an optical fiber for a surface plasmon resonance (SPR) sensor was proposed. The method is based on the electroless nickel plating and subsequent displacement gold plating of the core of the optical fiber. The thickness of the nickel and gold thin films deposited on the core of the optical fiber could be controlled by measuring the reflected light intensity from the tip of the optical fiber during the plating processes. The sensitivity and resolution of the SPR sensor with the fabricated optical fiber in the refractive index range from 1.333 to 1.348 were 1324.3 nm/RIU and 7.6 × 10-4 RIU, respectively. The developed SPR sensor was successfully used in the determination of immunoglobulin A (IgA) in human saliva. The IgA quantification results obtained by the SPR sensor were in excellent agreement with those obtained by conventional enzyme-linked immunosorbent assay using a 96-well microtiter plate.
Collapse
|
11
|
Nishitani Y, Kasai N, Nakajima H, Kato S, Mao S, Uchiyama K. Regioselective fabrication of gold nanowires using open-space laminar flow for attomolar protein detection. Chem Commun (Camb) 2022; 58:4308-4311. [PMID: 35262137 DOI: 10.1039/d2cc00507g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Gold nanowires are expected to be applied to biosensing due to their advantages, such as high stability and biocompatibility. However, it is still inconvenient to fabricate a single gold nanowire at a precise position, and without a special demanding environment. In this study, we present an open-space laminar flow approach for fabricating a single gold nanowire at a precise position under normal conditions. The fabricated gold nanowire demonstrated excellent biosensing of IgA with an extremely low limit of detection (1 aM).
Collapse
|
12
|
Horino T, Inotani S, Nakajima H, Ohnishi H, Komori M, Terada Y. Calcinosis and acro-osteolysis in systemic sclerosis. QJM 2022; 115:113-114. [PMID: 34963011 DOI: 10.1093/qjmed/hcab331] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
13
|
Morioka K, Osashima M, Azuma N, Qu K, Hemmi A, Shoji A, Murakami H, Teshima N, Umemura T, Uchiyama K, Nakajima H. Development of a fluorescence microplate reader using an organic photodiode array with a large light receiving area. Talanta 2022; 238:122994. [PMID: 34857327 DOI: 10.1016/j.talanta.2021.122994] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 10/18/2021] [Accepted: 10/21/2021] [Indexed: 11/28/2022]
Abstract
We developed a small fluorescence microplate reader with an organic photodiode (OPD) array. The OPD array has nine OPDs that have a large light receiving area (9.62 mm2 per one OPD). Since the OPD array is fabricated on a flat glass plate, it can be placed just below microwells and can detect fluorescence emitted through the entire surface of the microwell bottom. The analytical performance of the developed plate reader was evaluated by measuring an aqueous solution of resorufin. The limit of detection (LOD) for resorufin (0.01-0.05 μM) was lower than that obtained with a plate reader equipped with nine inorganic photodiodes developed in a previous study (0.30 μM) and a commercially available microplate reader (0.16 μM). These results indicate that the large light receiving area improves the detection performance of the system. In addition, the developed reader was successfully used to quantify immunoglobulin A (IgA) in human saliva. The LOD for IgA was estimated to be 1.2 ng/mL, which is low enough to objectively evaluate human stress.
Collapse
|
14
|
Zhou L, Kasai N, Nakajima H, Kato S, Mao S, Uchiyama K. In Situ Single-Cell Stimulation and Real-Time Electrochemical Detection of Lactate Response Using a Microfluidic Probe. Anal Chem 2021; 93:8680-8686. [PMID: 34107213 DOI: 10.1021/acs.analchem.1c01054] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Metabolism of a single cell, even within the same organization, differs from other cells by orders of magnitude. Single-cell analysis provides key information for early diagnosis of cancer as well as drug screening. Any slight change in the microenvironment may affect the state of a single cell. Timely and effective cell monitoring is conducive to better understand the behavior of single cells. The immediate response of a single cell described in this study is a liquid transfer-based approach for real-time electrochemical detection. The cell was in situ stimulated by continuous flow with glucose, and lactate secreted from the cell would diffuse into the microflow. The microflow was aspirated into the detection channel where lactate was then decomposed by coupled enzyme reactions and detected by an electrode. This work provides a novel approach for detecting lactate response from a single cell by noninvasive measurements, and the position resolution of the microfluidic probe reaches the level of a single cell and permits individual heterogeneity in cells to be explored in the diagnosis and treatment of cancer as well as in many other situations.
Collapse
|
15
|
Morita K, Morioka K, Nakajima H, Uchiyama K, Yanagida A, Shoji A. Film-Thickness-Controllable System for Preparing Silver Nanofilms through Absorbance Monitoring of the Thickness during a Silver-Mirror Reaction. ANAL SCI 2021; 37:625-631. [PMID: 33342923 DOI: 10.2116/analsci.20p400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
An innovative technique is proposed for forming silver thin films of nanometer-order thickness via a silver-mirror reaction. This approach is made possible by the real-time monitoring of the thickness of a silver thin film formed on the edge surface of a fiber core during the silver-mirror reaction using a homemade absorbance measurement system. The monitored absorbance value increases as silver plating progresses, and the relationship between the absorbance values and the thickness of the silver thin film is linear in the thickness range from approximately 30 to 60 nm. This technique was applied to the preparation of a fiber-optic surface plasmon resonance (FO-SPR) sensor. The sensor was successfully used to measure sucrose solutions with concentrations of less than 16% (w/v). The sensitivity of the sensor probe was estimated to be 2205 nm/RIU in the refractive index range of 1.333 - 1.357. The relative standard deviation of the wavelength shift obtained from measurements using different sensor probes was estimated to be less than 3.3%.
Collapse
|
16
|
Xu N, Lin H, Lin S, Zhang W, Han S, Nakajima H, Mao S, Lin JM. A Fluidic Isolation-Assisted Homogeneous-Flow-Pressure Chip-Solid Phase Extraction-Mass Spectrometry System for Online Dynamic Monitoring of 25-Hydroxyvitamin D 3 Biotransformation in Cells. Anal Chem 2021; 93:2273-2280. [PMID: 33443406 DOI: 10.1021/acs.analchem.0c04147] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
It is well known that cell can response to various chemical and mechanical stimuli. Therefore, flow pressure variation induced by sample loading and elution should be small enough to ignore the physical impact on cells when we use a Chip-SPE-MS system for cells. However, most existent Chip-SPE-MS systems ignored the pressure alternation because it is extremely difficult to develop a homogeneous-flow-pressure hyphenated module. Herein, we developed an interesting fluidic isolation-assisted homogeneous-flow-pressure Chip-SPE-MS system and demonstrated that it is adequate for online high-throughput determination and quantification of the 25-hydroxyvitamin D3 (25(OH)D3) biotransformation in different cells. Briefly, the homogeneous ambient flow pressure is achieved by fluidic isolation between the cell culture channel and the SPE column, and an automatic sampling probe could accomplish the sample loading and dispensing to fulfill online pretreatment of the sample. Through this new system, the expression levels of 24,25-dihydroxyvitamin D3 (24,25(OH)2D3) can be determined in real time with a detection limit of 2.54 nM. In addition, the results revealed that 25(OH)D3 metabolic activity differed significantly between normal L-02 cells and cancerous HepG2 cells. Treatment of L-02 cells with a high dose of 25(OH)D3 was found to increase significant formation of 24,25(OH)2D3, but this change was not apparent in HepG2 cells. The presented system promises to be a versatile tool for online accurate molecule biotransformation investigation and drug screening processes.
Collapse
|
17
|
Hamra A, Lim H, Huang N, Gowthaman N, Nakajima H, Rahman MM. Microwave exfoliated graphene-based materials for flexible solid-state supercapacitor. J Mol Struct 2020. [DOI: 10.1016/j.molstruc.2020.128710] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
18
|
Nakajima H, Kotani D, Oki E, Kato T, Shinozaki E, Sunakawa Y, Bando H, Yamazaki K, Yuki S, Yoshino T, Yamanaka T, Ohta T, Taniguchi H, Kagawa Y. P-18 REMARRY and PURSUIT trials: Liquid biopsy-guided re-challenge of anti-EGFR monoclonal antibody for patients with RAS/BRAF V600E wild-type metastatic colorectal cancer. Ann Oncol 2020. [DOI: 10.1016/j.annonc.2020.04.100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
19
|
Nathabumroong S, Eknapakul T, Jaiban P, Yotburut B, Siriroj S, Saisopa T, Mo SK, Supruangnet R, Nakajima H, Yimnirun R, Maensiri S, Meevasana W. Interplay of negative electronic compressibility and capacitance enhancement in lightly-doped metal oxide Bi 0.95La 0.05FeO 3 by quantum capacitance model. Sci Rep 2020; 10:5153. [PMID: 32198381 PMCID: PMC7083945 DOI: 10.1038/s41598-020-61859-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Accepted: 02/24/2020] [Indexed: 12/03/2022] Open
Abstract
Light-sensitive capacitance variation of Bi0.95La0.05FeO3 (BLFO) ceramics has been studied under violet to UV irradiation. The reversible capacitance enhancement up to 21% under 405 nm violet laser irradiation has been observed, suggesting a possible degree of freedom to dynamically control this in high dielectric materials for light-sensitive capacitance applications. By using ultraviolet photoemission spectroscopy (UPS), we show here that exposure of BLFO surfaces to UV light induces a counterintuitive shift of the O2p valence state to lower binding energy of up to 243 meV which is a direct signature of negative electronic compressibility (NEC). A decrease of BLFO electrical resistance agrees strongly with the UPS data suggesting the creation of a thin conductive layer on its insulating bulk under light irradiation. By exploiting the quantum capacitance model, we find that the negative quantum capacitance due to this NEC effect plays an important role in this capacitance enhancement
Collapse
|
20
|
Morioka K, Sato H, Morita K, Akihide H, Nakajima H, Shoji A, Yanagida A. Development of an on-chip sample injection system with a 6-port valve incorporated in a microchip. RSC Adv 2020; 10:35848-35855. [PMID: 35517096 PMCID: PMC9056900 DOI: 10.1039/d0ra07043b] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Accepted: 09/18/2020] [Indexed: 11/30/2022] Open
Abstract
Micro-flow-injection analysis (μFIA) is amenable to high-throughput systems with lower consumption of sample and reagent volumes. On-chip sample injection methods are important to prevent reduced analytical performance associated with dead volumes and diffusion of sample solutions. In this study, we have developed an on-chip sample injection system with a small-sized 6-port valve incorporated on a microchip. The valve is made with a 3D printer and is a simple structure that can be easily operated manually. A sample solution in a loading channel can be injected by switching the valve from the load to injection position. Sample injection tests using resorufin solutions revealed that samples can be injected below 100 μL min−1, and the performance of the sample injection system is comparable to that of a commercially available injector. In addition, the sample injection system was successfully applied to a flow-based assay for hydrogen peroxide. The detection limit (3σ) of hydrogen peroxide was estimated to be 0.5 μM, and the assay time after sample injection was approximately 100 s. The developed sample injection system will be useful for various microfluidic-based analyses including μFIA. We demonstrate on-chip sample injection using a 6-port valve incorporated in a microchip.![]()
Collapse
|
21
|
Woon KL, Wong WS, Chanlek N, Nakajima H, Tunmee S, Lee VS, Ariffin A, Songsiriritthigul P. Work function modification of PEDOT:PSS by mixing with barium acetylacetonate. RSC Adv 2020; 10:17673-17680. [PMID: 35515618 PMCID: PMC9053639 DOI: 10.1039/d0ra02575e] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Accepted: 04/23/2020] [Indexed: 11/21/2022] Open
Abstract
Poly(3,4-ethylenedioxythiophene)polystyrene sulfonate (PEDOT:PSS) is often used as a hole injection and extractor for various organic electronic devices. This study investigated whether it is possible to n-dope PEDOT:PSS with barium acetylacetonate (Ba(acac)2) to change its work function so that to be more suitable for electron injection and extraction. Molecular dynamics simulations suggested that barium cations can interact with the aromatic rings of PEDOT and the negatively charged sulfonate in PSS. At high doping concentration, we found that PEDOT became dedoped and precipitated resulting in a clear solution after filtration. The absence of the absorption peak of PEDOT at 263 nm indicates the removal of PEDOT after filtration. The shift in O 1s to a lower binding energy as seen in X-ray photoelectron spectroscopy suggested that the polystyrene sulfonic acids are being ionized to form barium polystyrene sulfonate (Ba–PSS). By spin-coating the solution on top of indium tin oxide, the work function can be adjusted to as low as 3.6 eV. The ability of such a mixture to inject and extract electrons is demonstrated using 2,7-bis(diphenylphosphoryl)-9,9′-spirobifluorene as an electron transporting layer. We attributed the lowering of the work function as the result of the formation of an interfacial dipole as large as 1.37 eV at the ITO/Ba–PSS interface. Modification of poly(3,4-ethylenedioxythiophene)polystyrene sulfonate as electron injection layer.![]()
Collapse
|
22
|
Phiri RR, Oladijo OP, Nakajima H, Rattanachata A, Akinlabi ET. Structural and morphological dataset for rf-sputtered WC-Co thin films using synchrotron radiation methods. Data Brief 2019; 25:104383. [PMID: 31516929 PMCID: PMC6728266 DOI: 10.1016/j.dib.2019.104383] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2018] [Accepted: 08/02/2019] [Indexed: 11/21/2022] Open
Abstract
Control and manipulation of synthesis parameters of thin film coatings is of critical concern in determination of material properties and performance. Structural and morphological properties of rf-sputtered WC-Co thin films deposited under varying deposition parameters namely, substrate temperature and rf power are presented in this data article. The surface morphology, crystallite size and nature were acquired using x-ray photoelectron spectroscopy (XPS) and Grazing Incidence X-ray absorption spectroscopy (GI-XAS). Furthermore, Synchrotron findings are correlated with complimentary data acquired from Scanning electron microscopy (SEM), Raman spectroscopy and surface profilometry to predict and point out optimum synthesis parameters for best properties of the film.
Collapse
|
23
|
Kaneko T, Sun Y, Nakajima H, Uchiyama K, Zeng H. Droplet Sensitized Fluorescence Detection for Enzyme-Linked Immune Sorbent Assays on Microwell Plate. Anal Chem 2019; 91:5685-5689. [DOI: 10.1021/acs.analchem.8b05668] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
24
|
Nakajima H, Morimoto T, Okigawa Y, Yamada T, Ikuta Y, Kawahara K, Ago H, Okazaki T. Imaging of local structures affecting electrical transport properties of large graphene sheets by lock-in thermography. SCIENCE ADVANCES 2019; 5:eaau3407. [PMID: 30746485 PMCID: PMC6358317 DOI: 10.1126/sciadv.aau3407] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Accepted: 12/13/2018] [Indexed: 05/30/2023]
Abstract
The distribution of defects and dislocations in graphene layers has become a very important concern with regard to the electrical and electronic transport properties of device applications. Although several experiments have shown the influence of defects on the electrical properties of graphene, these studies were limited to measuring microscopic areas because of their long measurement times. Here, we successfully imaged various local defects in a large area of chemical vapor deposition graphene within a reasonable amount of time by using lock-in thermography (LIT). The differences in electrical resistance caused by the micrometer-scale defects, such as cracks and wrinkles, and atomic-scale domain boundaries were apparent as nonuniform Joule heating on polycrystalline and epitaxially grown graphene. The present results indicate that LIT can serve as a fast and effective method of evaluating the quality and uniformity of large graphene films for device applications.
Collapse
|
25
|
Furuya H, Ikeda K, Iida K, Suzuki K, Furuta S, Tamachi T, Suzuki K, Miura G, Hiraguri M, Hase R, Hikosaka K, Norose K, Nakajima H. Disseminated toxoplasmosis with atypical symptoms which developed with exacerbation of systemic lupus erythematosus. Lupus 2018; 28:133-136. [PMID: 30486727 DOI: 10.1177/0961203318815583] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Toxoplasma is a common parasite worldwide that mainly affects the brain, lungs and eyes. Although toxoplasmic encephalitis is a lethal disease without treatment, past case reports show most patients with systemic lupus erythematosus who developed toxoplasmic encephalitis were misdiagnosed and treated as neuropsychiatric systemic lupus erythematosus, which led to unfavorable outcomes. We herein describe a case of disseminated toxoplasmosis affecting all the above organs with atypical symptoms, which developed with exacerbation of systemic lupus erythematosus. She had initially manifested with retinochoroiditis without vitritis, mild cognitive impairment and an isolated lung mass. These are completely different from the classic symptoms of toxoplasmosis that have been reported in patients with HIV infection and/or those after hematopoietic transplantation. Our case, together with previously reported cases, suggests the manifestation of toxoplasmosis that develops in systemic lupus erythematosus patients can be different from that seen in conventional cases and varies between individual patients. Our case highlights both the difficulty in and the importance of diagnosing toxoplasmosis in patients with systemic lupus erythematosus and provides helpful information to identify this rare, devastating, yet treatable disease.
Collapse
|