26
|
Xu Q, Yang Z, Sun Y, Lai L, Jin Z, Ding G, Zhao X, Yao J, Wang J. Shock-Resistibility of MEMS-Based Inertial Microswitch under Reverse Directional Ultra-High g Acceleration for IoT Applications. Sci Rep 2017; 7:45512. [PMID: 28361893 PMCID: PMC5374543 DOI: 10.1038/srep45512] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2016] [Accepted: 02/27/2017] [Indexed: 11/09/2022] Open
Abstract
This paper presents a novel MEMS-based inertial microswitch design with multi-directional compact constraint structures for improving the shock-resistibility. Its shock-resistibility in the reverse-sensitive direction to ultra-high g acceleration (~hunderds of thousands) is simulated and analyzed. The dynamic response process indicates that in the designed inertial microswitch the proof mass weight G, the whole system’s stiffness k and the gap x2 between the proof mass and reverse constraint blocks have significant effect on the shock-resistibility. The MEMS inertial microswitch micro-fabricated by surface micromachining has been evaluated using the drop hammer test. The maximum allowable reverse acceleration, which does not cause the spurious trigger, is defined as the reverse acceleration threshold (athr). Test results show that athr increases with the decrease of the gap x2, and the proposed microswitch tends to have a better shock-resistibility under smaller gap. The measured responses of the microswitches with and without constraint structure indicates that the device without constraint structure is prone to spurious trigger, while the designed constraint structures can effectively improve the shock-resistibility. In this paper, the method for improving the shock-resistibility and reducing the spurious trigger has been discussed.
Collapse
|
27
|
Sun B, Wang Y, Ding G. Flexible Field Emitter for X-ray Generation by Implanting CNTs into Nickel Foil. NANOSCALE RESEARCH LETTERS 2016; 11:393. [PMID: 27613070 PMCID: PMC5017995 DOI: 10.1186/s11671-016-1598-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Accepted: 08/20/2016] [Indexed: 06/06/2023]
Abstract
This paper reports on a flexible Ni micro wire with CNTs embedded into its surface. By using micromachining technology, for the first time, we could implant nanoscale materials into micro-scale metal substrate at room temperature. Thanks to the effective direct contact and the strong interactions between CNTs and the substrate, field emission current of 1.11 mA (current density of 22.2 mA/cm(2)) could be achieved from the micro wire. Moreover, the wire shows excellent mechanical properties for large amplitude bending, which is beneficial for geometric designing. To check the practical application of the wire, a simplified X-ray imaging system was set up by modifying a conventional tube. The gray shade that appears on the sensitive film after being exposed to the radiation confirms the X-ray generation.
Collapse
|
28
|
Sun B, Wang Y, Ding G. Flexible Field Emitter for X-ray Generation by Implanting CNTs into Nickel Foil. NANOSCALE RESEARCH LETTERS 2016; 11:326. [PMID: 27401089 PMCID: PMC4940312 DOI: 10.1186/s11671-016-1523-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2016] [Accepted: 06/07/2016] [Indexed: 06/06/2023]
Abstract
This paper reports a novel implanting micromachining technology. By using this method, for the first time, we could implant nano-scale materials into milli-scale metal substrates at room temperature. Ni-based flexible carbon nanotube (CNT) field emitters were fabricated by the novel micromachining method. By embedding CNT roots into Ni foil using polymer matrix as transfer media, effective direct contact between Ni and CNTs was achieved. As a result, our novel emitter shows relatively good field emission properties such as low turn-on field and good stability. Moreover, the emitter was highly flexible with preservation of the field emission properties. The excellent field emission characteristics attributed to the direct contact and the strong interactions between CNTs and the substrate. To check the practical application of the novel emitter, a simple X-ray imaging system was set up by modifying a traditional tube. The gray shadow that appears on the sensitive film after being exposed to the radiation confirms the successful generation of X-ray.
Collapse
|
29
|
Sullivan A, Ding G. SU-E-J-06: Additional Imaging Guidance Dose to Patient Organs Resulting From X-Ray Tubes Used in CyberKnife Image Guidance System. Med Phys 2016. [DOI: 10.1118/1.4924094] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
30
|
Ding G. SU-E-J-23: Characteristics of X-Rays From ExacTrac and Patient Dose From Imaging Procedures. Med Phys 2016. [DOI: 10.1118/1.4924110] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
31
|
Liu L, Wang Y, Yao J, Yang C, Ding G. A minimally invasive micro sampler for quantitative sampling with an ultrahigh-aspect-ratio microneedle and a PDMS actuator. Biomed Microdevices 2016; 18:59. [PMID: 27372944 DOI: 10.1007/s10544-016-0086-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
This study describes a novel micro sampler consisting of an ultrahigh-aspect-ratio microneedle and a PDMS actuator. The microneedle was fabricated by a new method which introduced reshaped photoresist technology to form a flow channel inside. The microneedle includes two parts: shaft and pedestal. In this study, the shaft length is 1500 μm with a 45° taper angle on the tip and pedestal is 1000 μm. Besides, the shaft and pedestal are connected by an arc connection structure with a length of 600 μm. The microneedles have sufficient mechanical strength to insert into skin with a wide safety margin which was proved by mechanics tests. Moreover, a PDMS actuator with a chamber inside was designed and fabricated in this study. The chamber, acting as a reservoir in sampling process as well as providing power, was optimized by finite element analysis (FEA) to decrease dead volume and improve sampling precision. The micro sampler just needs finger press to activate the sampling process as well as used for quantitative micro injection to some extent. And a volume of 31.5 ± 0.8 μl blood was successfully sampled from the ear artery of a rabbit. This micro sampler is suitable for micro sampling for diagnose or therapy in biomedical field.
Collapse
|
32
|
|
33
|
Ding G. SU-F-T-225: Is It Time to Have Pre-Configured Therapeutic Beams Available in Commercial Treatment Planning Systems? Med Phys 2016. [DOI: 10.1118/1.4956364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
34
|
Herchko S, Ding G. SU-F-T-486: A Simple Approach to Performing Light Versus Radiation Field Coincidence Quality Assurance Using An Electronic Portal Imaging Device (EPID). Med Phys 2016. [DOI: 10.1118/1.4956671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
35
|
Ding G. TU-B-201-01: An Overview of TG-180. Med Phys 2016. [DOI: 10.1118/1.4957452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
36
|
Ding G. SU-F-J-179: Commissioning Dosimetric Data of a New 2.5 Megavoltage Imaging Beam from a TrueBeam Linear. Med Phys 2016. [DOI: 10.1118/1.4956087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
37
|
Ding G, Yin F, Ren L. SU-G-JeP3-06: Lower KV Image Dose Are Expected From a Limited-Angle Intra-Fractional Verification (LIVE) System for SBRT Treatments. Med Phys 2016. [DOI: 10.1118/1.4957071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
38
|
Xie J, Zhao D, Zhao L, Pei J, Xiao W, Ding G, Wang Z, Xu J. Characterization of a novel arabinose-tolerant α
-l-
arabinofuranosidase with high ginsenoside Rc to ginsenoside Rd bioconversion productivity. J Appl Microbiol 2016; 120:647-60. [DOI: 10.1111/jam.13040] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2015] [Revised: 11/13/2015] [Accepted: 12/28/2015] [Indexed: 11/30/2022]
|
39
|
Yeo G, Gupta A, Ding G, Skerman H, Khatun M, Melsom D. Pain Levels after Local Anaesthetic with or without Hyaluronidase in Carpal Tunnel Release: A Randomised Controlled Trial. Adv Orthop 2015; 2015:784329. [PMID: 26587288 PMCID: PMC4637433 DOI: 10.1155/2015/784329] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2015] [Accepted: 10/15/2015] [Indexed: 01/06/2023] Open
Abstract
Purpose. Hyaluronidase is an enzyme that temporarily liquefies the interstitial barrier, allowing easy dispersal of local anaesthetic through cleavage of tissue planes. This prospective, blinded, randomised controlled study investigates the utility of adding hyaluronidase to local anaesthetic in the setting of carpal tunnel release. Methods. 70 consecutive carpal tunnel release patients were recruited and randomised into a control group only receiving local anaesthetic and a hyaluronidase group receiving both hyaluronidase and local anaesthetic. Pain scores were rated using the visual analogue scale (VAS) by patients immediately after local anaesthetic injection and again immediately after the carpal tunnel release. Results. Preoperative VAS scores, taken after local anaesthetic injection, were greater than postoperative VAS scores. Postoperative VAS scores were significantly lower in the hyaluronidase group and tourniquet times were significantly shorter in the hyaluronidase group. Conclusion. Hyaluronidase addition to local anaesthetic in carpal tunnel release resulted in significant reductions in operative time and pain immediately after operation.
Collapse
|
40
|
Netherton T, Ding G. SU-E-T-316: Dosimetric Effects Resulting From Increased MLC Error and Expanded Dose Dynamic Leaf Tolerances in Sliding Window IMRT. Med Phys 2015. [DOI: 10.1118/1.4924677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
41
|
Liu F, Tai A, Lee P, Biswas T, Ding G, El Naqa I, Grimm J, Jackson A, Kong F, LaCouture T, Loo B, Miften M, Solberg T, Li X. TH-AB-304-04: Tumor Control Probability Modeling for Stereotactic Body Radiation Therapy of Early-Stage Lung Cancer Using Multiple Bio-Physical Models. Med Phys 2015. [DOI: 10.1118/1.4926119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
42
|
Ding G. TH-C-BRD-03: Techniques to Reduce Radiation Dose Resulting From Daily Imaging Guidance Procedures. Med Phys 2015. [DOI: 10.1118/1.4926221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
43
|
Ding G, Wang L. SU-E-J-08: Comparison of Unintended Radiation Doses to Organs at Risk Resulting From the Out-Of-Field Therapeutic Beams and From Image-Guidance X-Ray Procedures. Med Phys 2015. [DOI: 10.1118/1.4924096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
44
|
Morales-Paliza M, Ding G. SU-E-T-741: The Resources and Cost to Operate An Intraoperative Radiation Therapy Program for Accelerated Partial Breast Irradiation Using a Low-Energy X-Ray Source. Med Phys 2015. [DOI: 10.1118/1.4925105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
45
|
Wang L, Ding G. SU-E-T-381: Evaluation of Calculated Dose Accuracy for Organs-At-Risk Located at Out-Of-Field in a Commercial Treatment Planning System for High Energy Photon Beams Produced From TrueBeam Accelerators. Med Phys 2015. [DOI: 10.1118/1.4924742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
46
|
Penoncello G, Ding G. SU-E-T-694: Significant Skin Dose Differences Between IMRT and VMAT and Between Boost and Integrated Treatment Regimens for Treating Head and Neck and Other Cancer Site Patients. Med Phys 2015. [DOI: 10.1118/1.4925058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
47
|
Frank K, Ding G, Raue F, Ziegler R. Can the routine treatment of Graves' orbitopathy be efficiently supplemented by the administration of Venalot? DEVELOPMENTS IN OPHTHALMOLOGY 2015; 20:127-9. [PMID: 2687048 DOI: 10.1159/000417928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
48
|
Ding G. SP-0601: Monte Carlo simulations of kV imaging beams and methods of managing imaging doses to radiotherapy patients:. Radiother Oncol 2015. [DOI: 10.1016/s0167-8140(15)40595-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
49
|
Yin J, Wang X, Wei J, Wang L, Shi Y, Zheng L, Tang W, Ding G, Liu C, Liu R, Chen S, Xu Z, Gu H. Interleukin 12B rs3212227 T > G polymorphism was associated with an increased risk of gastric cardiac adenocarcinoma in a Chinese population. Dis Esophagus 2015; 28:291-8. [PMID: 24529168 DOI: 10.1111/dote.12189] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Gastric cardiac adenocarcinoma (GCA) is one of common malignant tumors in the world. Multiple genes that play critical roles in inflammatory pathways probably are associated with GCA risk. We conducted a hospital-based case-control study to evaluate the genetic effects of functional single nucleotide polymorphisms (SNPs): interleukin 9 (IL9) rs31563 C > T, IL9 rs31564 G > T, IL10 rs1800872 T > G, IL12A rs2243115 T > G, IL12B rs3212227 T > G, and IL13 rs1800925 C > T on the development of GCA. Two hundred and forty-three GCA cases and 476 controls were recruited. Their genotypes were determined using a custom-by-design 48-Plex SNPscan kit. IL12B rs3212227 T > G polymorphism was associated with the increased risk of GCA. However, there was no significant association between the other five SNPs and GCA risk. Stratified analyses indicated that the risk of GCA associated with the IL12B rs3212227 T > G polymorphism was evident among female patients and patients who never smoked or consumed alcoholic drinks. These findings indicated that functional polymorphism IL12B rs3212227 T > G might correlate with GCA risk. However, our results were obtained with a limited sample size; the power of our analysis was low. Larger studies are required to confirm the current findings.
Collapse
|
50
|
Wei FL, Wang JH, Ding G, Yang SY, Li Y, Hu YJ, Wang SL. Mechanical force-induced specific MicroRNA expression in human periodontal ligament stem cells. Cells Tissues Organs 2015; 199:353-63. [PMID: 25823370 DOI: 10.1159/000369613] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/06/2014] [Indexed: 01/14/2023] Open
Abstract
It remains unclear how the expression of microRNAs (miRNAs) in human periodontal ligament stem cells (PDLSCs) might respond to mechanical stretch. To investigate specific miRNA expression in stretched PDLSCs, we used a Flexcell® FX-5000™ tension system to achieve external mechanical stimulation. Then, a custom-designed microarray assay was performed to investigate and describe the genome-wide differential expression of miRNAs in normal and stretched PDLSCs. Finally, we implemented integrative miRNA target prediction and network analysis approaches to construct an interaction network of the key miRNAs and their putative targets. We found that stretching induced morphological changes and increased alkaline phosphatase (ALP) activity, runt-related transcription factor 2 (RUNX2), osteocalcin (OCN), and bone sialoprotein (BSP) expression in PDLSCs. The microarray data showed that 53 miRNAs were differentially expressed with stretching. With an interaction network, we examined the connections between 10 selected key miRNAs and their putative target genes, which were related to mechanical force. The results from the interaction network provided a basis for postulating the functional roles of miRNAs in PDLSCs.
Collapse
|