26
|
Davies J, Stratford J, Duffy M, Pennington H, Whitehurst P, Rowbottom C, Mackay R, Gattamaneni H. THE TREATMENT AND 3D VERIFICATION OF AN INVERSE PLANNED IMRT FOR THE WHOLE CENTRAL NERVOUS SYSTEM. Radiother Oncol 2009. [DOI: 10.1016/s0167-8140(12)72715-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
27
|
McBain C, Green M, Stratford J, Davies J, McCarthy C, Taylor B, McHugh D, Swindell R, Khoo V, Price P. Ultrasound Imaging to Assess Inter- and Intra-fraction Motion during Bladder Radiotherapy and its Potential as a Verification Tool. Clin Oncol (R Coll Radiol) 2009; 21:385-93. [DOI: 10.1016/j.clon.2009.01.016] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2008] [Revised: 01/20/2009] [Accepted: 01/21/2009] [Indexed: 10/21/2022]
|
28
|
|
29
|
Booth MI, Stratford J, Jones L, Dehn TCB. Authors' reply: Randomized clinical trial of laparoscopic total (Nissen) versus posterior partial (Toupet) fundoplication for gastro-oesophageal reflux disease based on preoperative oesophageal manometry (Br J Surg 2008; 95: 57–63). Br J Surg 2008. [DOI: 10.1002/bjs.6282] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
30
|
Booth MI, Stratford J, Jones L, Dehn TCB. Randomized clinical trial of laparoscopic total (Nissen) versus posterior partial (Toupet) fundoplication for gastro-oesophageal reflux disease based on preoperative oesophageal manometry. Br J Surg 2007; 95:57-63. [DOI: 10.1002/bjs.6047] [Citation(s) in RCA: 119] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Abstract
Background
Laparoscopic fundoplication is an accepted treatment for symptomatic gastro-oesophageal reflux disease. The aim of this study was to clarify whether total (Nissen) or partial (Toupet) fundoplication is preferable, and whether preoperative oesophageal manometry should be used to determine the degree of fundoplication performed.
Methods
Preoperative oesophageal manometry was used to stratify 127 patients with established gastro-oesophageal reflux disease into effective (75) and ineffective (52) oesophageal motility groups. Patients in each group were randomized to Nissen (64) or Toupet (63) fundoplication.
Results
No significant differences between the operative groups were seen in heartburn, regurgitation or other reflux-related symptoms up to 1 year after surgery. Dysphagia of any degree (27 versus 9 per cent; P = 0·018) and chest pain on eating (22 versus 5 per cent; P = 0·018) were more prevalent at 1 year in the Nissen group. There were no differences in postoperative symptoms between the effective and ineffective motility groups. Surgery failed in eight patients on postoperative pH criteria, three in the Nissen group and five in the Toupet group.
Conclusion
Any differences in the symptomatic outcome of laparoscopic Nissen and Toupet fundoplication appear minimal. There is no reason to tailor the degree of fundoplication to preoperative oesophageal manometry.
Collapse
|
31
|
Sripadam R, Amer A, Marchant T, Stratford J, McCarthy C, Faivre-Finn C, Moore C, Price P. Respiratory Intrafraction Motion is an Important Source of Error in Radiotherapy to Oesophago-gastric Junction (OGJ) Cancers. Int J Radiat Oncol Biol Phys 2007. [DOI: 10.1016/j.ijrobp.2007.07.1312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
32
|
Gill J, Booth MI, Stratford J, Dehn TCB. The extended learning curve for laparoscopic fundoplication: a cohort analysis of 400 consecutive cases. J Gastrointest Surg 2007; 11:487-92. [PMID: 17436134 PMCID: PMC1852390 DOI: 10.1007/s11605-007-0132-0] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Many studies have looked at the learning curve associated with laparoscopic Nissen fundoplication (LNF) in a given institution. This study looks at the learning curve of a single surgeon with a large cohort of patients over a 10-year period. Prospective data were collected on 400 patients undergoing laparoscopic fundoplication for over 10 years. The patients were grouped consecutively into cohorts of 50 patients. The operating time, the length of postoperative hospital stay, the conversion rate to open operation, the postoperative dilatation rate, and the reoperation rate were analyzed. Results showed that the mean length of operative time decreased from 143 min in the first 50 patients to 86 min in the last 50 patients. The mean postoperative length of hospital stay decreased from 3.7 days initially to 1.2 days latterly. There was a 14% conversion to open operation rate in the first cohort compared with a 2% rate in the last cohort. Fourteen percent of patients required reoperation in the first cohort and 6% in the last cohort. Sixteen percent required postoperative dilatation in the first cohort. None of the last 150 patients required dilatation. In conclusion, laparoscopic fundoplication is a safe and effective operation for patients with gastroesophageal reflux disease. New techniques and better instrumentation were introduced in the early era of LNF. The learning curve, however, continues well beyond the first 20 patients.
Collapse
|
33
|
McCarthy C, Davies J, Stratford J, Duffy M, Gattamaneni HR. X-ray Volumetric Imaging in Paediatric Radiotherapy — a Case Study. Clin Oncol (R Coll Radiol) 2007; 19:194-6. [PMID: 17359906 DOI: 10.1016/j.clon.2006.11.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2006] [Revised: 10/16/2006] [Accepted: 11/24/2006] [Indexed: 10/23/2022]
|
34
|
Davies J, Stratford J. Teaching Session B: Auditing and Monitoring Set up Errors in Radiotherapy. Clin Oncol (R Coll Radiol) 2007. [DOI: 10.1016/j.clon.2007.01.299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
35
|
Jain P, Amer A, Stratford J, Saleem A, Moore C, Price P. X-ray Volumetric Imaging (XVI) to Redefine Radiotherapy Margins for Locally Advanced Pancreatic Cancer (LAPC). Clin Oncol (R Coll Radiol) 2007. [DOI: 10.1016/j.clon.2007.01.372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
36
|
Moore CJ, Amer A, Marchant T, Sykes JR, Davies J, Stratford J, McCarthy C, MacBain C, Henry A, Price P, Williams PC. Developments in and experience of kilovoltage X-ray cone beam image-guided radiotherapy. Br J Radiol 2006; 79 Spec No 1:S66-78. [PMID: 16980686 DOI: 10.1259/bjr/68255935] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
This paper offers a realistic review of kilovoltage X-ray cone beam tomography integrated with the treatment machine for image-guided radiotherapy in the light of experience taking a commercial system from prototype development into clinical use. It shows that key practicalities cannot be ignored, in particular the regular characterization of mechanical flex during gantry rotation, the mapping of defects in flat panel image transducers and their response to X-ray exposure. The number of X-ray projections and the doses required for clinically useful cone beam reconstruction at different therapy sites are considered in the context of imaging that is fit for purpose. Three roles for cone beam tomography in radiotherapy are identified: patient setup in three dimensions (3D), where even low dose cone beam tissue detail is superior to megavoltage imaging; disease targeting where, despite wide field scatter and slow scanning, it is possible to generate images that are suitable for tumour delineation even at challenging sites; adaptive treatment planning, where calibrated cone beam images have been shown to provide sufficient target detail to support "plan of the day" selection and have the potential for planning with bulk corrections. With frequent use in mind, the need to limit patient dose during setup, yet maximize much needed image quality in the target zone, is considered. Finally, it is noted that the development of cone beam tomography for radiotherapy is far from complete, with X-ray source, image transducer, reconstruction algorithms and techniques for image profile collection still being researched.
Collapse
|
37
|
Stratford J, Ball K, Henry AM, Cullen JN, Swindell R, Price P, Jain P. Radiotherapy Treatment Verification in the UK: An Audit of Practice in 2004. Clin Oncol (R Coll Radiol) 2006; 18:15-22. [PMID: 16477915 DOI: 10.1016/j.clon.2005.09.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
AIMS To audit current practice related to treatment verification undertaken in radiotherapy departments throughout the UK. MATERIALS AND METHODS A questionnaire was circulated to the radiotherapy service managers of 62 radiotherapy centres in the UK. This looked in detail at the department demographics, imaging equipment, site-specific verification protocols, and training and competency assessment of staff responsible for verification. RESULTS The response rate was 48% (30/62). All departments were using megavoltage imaging equipment in routine clinical practice. Twenty-four out of 29 (83%) departments that had electronic portal imaging capability were using image analysis software for verification. Twenty-nine out of 30 (97%) departments had site-specific written verification protocols. Twenty out of 30 (67%) treatment centres audited set-up errors within their department. Forty-three per cent of centres were using simulator image as the reference image of choice across all sites. Electronic portal imaging, alone or in combination with portal film, was being used for verification in 75% of the centres. Fifty-three per cent of centres used off-line correction strategies for measuring set-up errors across all sites. Radiographer-led interventions were primarily in the pelvis. CONCLUSION Presently in the UK, verification strategies vary widely at individual treatment sites and between departments. Dedicated departmental verification teams, with input from radiographers, physicists and clinicians, may assist in the effective implementation of evidence-based verification. The inclusion of comprehensive verification protocols within multicentre radiotherapy trials encourages standardisation across treatment centres.
Collapse
|
38
|
Henry AM, Stratford J, Davies J, McCarthy C, Swindell R, Sykes J, Moore CJ, Price P, Khoo VS. An assessment of clinically optimal gold marker length and diameter for pelvic radiotherapy verification using an amorphous silicon flat panel electronic portal imaging device. Br J Radiol 2005; 78:737-41. [PMID: 16046426 DOI: 10.1259/bjr/97956788] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Verification of target organ position is essential for the accurate delivery of conformal radiotherapy. Megavoltage electronic portal imaging with flat panel amorphous silicon detectors delivers high quality images that can be used for verification of bony landmark position. Gold markers implanted into the target organ can be visualized and used as a surrogate of actual organ position. On-line compensation for marker displacement, by adjusting patient position, can reduce geometric errors associated with radiation delivery. This study assesses the optimal marker length and diameter to be used with an amorphous silicon (a-Si) flat panel detector and electronic portal images (EPIs), prior to implementation of a clinical programme of gold marker insertion in prostate cancer patients. Seven marker sizes varying from 3 mm to 8 mm in length and 0.8 mm to 1.1 mm in diameter were investigated in a group of patients undergoing pelvic radiotherapy using an 8 MV Elekta SL20 linear accelerator. Markers were placed on the skin entry and exit sites of the treatment beam and EPIs in both lateral and anterior pelvic views were acquired. Three observers independently assessed visibility success and failure using a subjective scoring system. Markers less than 5 mm in length or 0.9 mm in diameter were poorly visualized (<70% visualization success in lateral EPIs). The marker measuring 0.9 mm x 5 mm appears to be clinically optimal in pelvic radiotherapy patients (80% visualization success in lateral EPIs) and will be used for actual organ implantation.
Collapse
|
39
|
Stratford J, McCarthy C, Davies J, Duffy M. 21 Image guided radiotherapy: clinical and practical experience using X-ray volumetric imaging. Radiother Oncol 2005. [DOI: 10.1016/s0167-8140(05)80975-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
40
|
Marchand T, Amer A, Moore C, Stratford J. 275 Comparison of set up errors measured in 2D and 3D using EPI and cone beam CT. Radiother Oncol 2005. [DOI: 10.1016/s0167-8140(05)81251-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
41
|
Wilkerson PM, Stratford J, Jones L, Sohanpal J, Booth MI, Dehn TCB. A poor response to proton pump inhibition is not a contraindication for laparoscopic antireflux surgery for gastro esophageal reflux disease. Surg Endosc 2005; 19:1272-7. [PMID: 16025197 DOI: 10.1007/s00464-004-2238-8] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2004] [Accepted: 03/17/2005] [Indexed: 11/25/2022]
Abstract
BACKGROUND We aimed to determine if a poor response to proton pump inhibitors (PPIs) can predict a poor outcome following laparoscopic antireflux surgery (LARS) in our surgically treated population. METHODS A total of 324 patients undergoing LARS were included in this study. Following standardized assessment, patients recorded the efficacy of their medication on visual analogue scales. Pre- and postoperative symptom scores were recorded, with outcomes measured by modified Visick scores. RESULTS There were 233 good responders (>50% relief) and 91 poor responders (<49% relief). Both groups demonstrated a significant decline in postoperative symptom scores. Ninety-four percent of good responders had an excellent or good outcome, compared to 87% of poor responders. Twenty-seven patients reported a fair or poor outcome, despite improved postoperative symptom scores. Fifteen of these patients reported continuing heartburn; five had positive pH tests. CONCLUSION Our results do not support the assumption that a poor response to PPIs equates to a poor outcome after LARS.
Collapse
|
42
|
Menon KV, Booth M, Stratford J, Dehn TCB. Laparoscopic fundoplication in mentally normal children with gastroesophageal reflux disease. Dis Esophagus 2003; 15:163-6. [PMID: 12220426 DOI: 10.1046/j.1442-2050.2002.00245.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Laparoscopic antireflux surgery has been performed in neurologically impaired and scoliotic children. We aimed to assess the effectiveness of laparoscopic fundoplication in mentally normal children with gastroesophageal reflux disease that failed to respond to medical therapy. Data were prospectively collected (symptoms, medical therapy, endoscopies' findings) on 12 children (nine boys, three girls) aged 9-15 years with gastroesophageal reflux disease. Pre- and postoperative ambulatory 24-h pH and DeMeester and Johnson scores were also recorded. Effectiveness of surgery was assessed by comparison of pre- and postoperative total acid exposure time, Visick grade, need for antireflux medication and symptom scores. In total, 11 children underwent a laparoscopic Nissen fundoplication and one underwent a Toupet procedure. Median length of stay was 2 (2-3) nights. The median preoperative pH acid exposure time (AET) was 4.7 (0.8-16.4) percent compared with postoperative AET of 0.4 (0-3) percent. Early postoperative dysphagia occurred in four out of 12 patients, requiring a total of six dilatations. Postoperative Visick scores were: grade I=7 and grade II=5. Laparoscopic fundoplication can be safely performed and is effective in children with GERD who have failed to respond to medical therapy.
Collapse
|
43
|
Booth M, Stratford J, Dehn TCB. Preoperative esophageal body motility does not influence the outcome of laparoscopic Nissen fundoplication for gastroesophageal reflux disease. Dis Esophagus 2002; 15:57-60. [PMID: 12060044 DOI: 10.1046/j.1442-2050.2002.00229.x] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
We evaluated a policy of performing laparoscopic antireflux surgery without tailoring the procedure to the results of preoperative esophageal motility tests. A total of 117 patients (82 with normal esophageal motility; 35 with ineffective motility, IEM) underwent laparoscopic Nissen fundoplication for symptomatic gastroesophageal reflux. There were no significant differences in preoperative symptom length, dysphagia, DeMeester symptom scores, acid exposure times or lower esophageal sphincter pressures between the two groups. Both groups showed postoperative improvements in DeMeester symptom scores, dysphagia and acid exposure, with no differences between groups. At 1 year after surgery, 95% of the normal motility group and 91% of the IEM group had a good/excellent outcome from surgery. None of the IEM group required postoperative dilatation or reoperation. Patients with IEM fare equally well from laparoscopic Nissen fundoplication as those with normal esophageal motility. There is no merit in tailoring antireflux surgery to the results of preoperative motility tests.
Collapse
|
44
|
Dyke PH, Stratford J. Changes to the TEF schemes can have significant impacts on regulation and management of PCDD/F and PCB. CHEMOSPHERE 2002; 47:103-116. [PMID: 11993627 DOI: 10.1016/s0045-6535(01)00219-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The changes recommended by the World Health Organisation (WHO) to the toxic equivalency factors (TEFs) for polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/F) and the recommendation to extend both the TEF scheme and the tolerable daily intake (TDI) to include "dioxin-like" PCB congeners have significant implications for regulators who have relied heavily on the International TEF (I-TEF) scheme in setting and monitoring limits and exposure to these compounds. This paper examines example data sets of sources, environmental concentrations, food and exposure to indicate likely changes in calculated toxic equivalent (TEQ) due to the recommended changes to TEFs. Many published data sets available do not provide congener specific data for PCDD/F which limits the ability to recalculate TEQs. There are even fewer congener specific data published to enable calculation of TEQs for the dioxin-like PCBs. In general TEQs calculated using the WHO scheme for emissions to air were found to show small increases (in the order of 1-10%) in comparison to the I-TEQ (for PCDD/F), some sludge samples showed substantial decreases (up to 70%). Levels in food and calculations of exposure showed that the change to TEFs for PCDD/F increased calculated exposure by 10-20% while the change to PCB TEFs decreased calculated TEQ attributable to PCB by 0-10%. The effects of including PCB in the overall TEQ and the changes to TEFs for PCDD/F substantially increase calculated TEQ exposure. Congener specific data should be presented to allow calculation of desired TEQ and the impact of the changes on emission limits, regulations on sludge use and environmental quality standards should all be carefully considered. The absence of data on emissions of dioxin-like PCB means that it is not possible to estimate with any certainty the impact on overall TEQ emissions of including the nominated PCB. Given the potential for confusion with the proliferation of TEFs and the extension to include both PCDD/F and PCB in the calculation of TEQs it is important that great care is taken to clearly express which compounds are included and which TEF scheme has been applied in each case.
Collapse
|
45
|
Booth MI, Jones L, Stratford J, Dehn TCB. Results of laparoscopic Nissen fundoplication at 2-8 years after surgery. Br J Surg 2002; 89:476-81. [PMID: 11952591 DOI: 10.1046/j.0007-1323.2002.02074.x] [Citation(s) in RCA: 95] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Although the long-term results of open fundoplication for gastro-oesophageal reflux disease are well documented, there have been few reports of the long-term results of laparoscopic fundoplication. METHODS Between January 1993 and July 1999, 179 consecutive patients underwent laparoscopic floppy Nissen fundoplication. Of these, 175 were available for long-term follow-up. Structured symptom questionnaires were completed by 140 patients (80 per cent) at 2-5 years (n = 92) or 5-8 years (n = 48) after operation. RESULTS Patient satisfaction with surgery was 91 per cent at a median follow-up of 48 (range 24-99) months. Visick scores of I or II were recorded by 84 per cent. Ninety per cent of patients remained free from significant reflux symptoms. Side-effects were common (22 per cent) but rarely affected patient satisfaction. Of the 19 patients (14 per cent) taking regular antireflux medication, eight used it for non-reflux symptoms and 12 had normal postoperative pH tests. CONCLUSION Laparoscopic floppy Nissen fundoplication is an effective and durable treatment for gastro-oesophageal reflux disease. Longer-term follow-up of patients operated on beyond the learning curve can be expected to show further improvements in surgical outcome.
Collapse
|
46
|
Booth MI, Stratford J, Dehn TC. Patient self-assessment of test-day symptoms in 24-h pH-metry for suspected gastroesophageal reflux disease. Scand J Gastroenterol 2001; 36:795-9. [PMID: 11495072 DOI: 10.1080/003655201750313298] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Marked daily fluctuations may occur in the pattern and degree of gastroesophageal reflux (GOR) and in patients' symptoms. The aim of this study was to observe how patients' self-assessment of their symptoms on the day of a 24-h pH test correlates with the likely outcome of the test and the potential value in repeating it. METHODS 367 patients with symptoms suggestive of GOR underwent 24-h pH tests. Fifty-eight patients had repeat studies. Patients assessed the severity of their test-day symptoms as 'better than typical', 'typical' or 'worse than typical'. RESULTS A 'typical' or 'worse than typical' day was more likely to produce an abnormal test result (P < 0.0001). A normal first test on a 'better than typical' day was more likely to be followed by an abnormal second test than a normal first test on a 'typical' or 'worse than typical' day (55% versus 22%; P = 0.025). The symptom index score, the total acid exposure time on the first test and the presence of oesophagitis were not associated with an abnormal second test (P not significant). CONCLUSIONS Patients' self-assessment of the severity of their test-day symptoms should be included in the interpretation of 24-h pH tests for suspected GOR. Patients with a normal pH test on a 'better than typical day warrant a repeat test.
Collapse
|
47
|
Booth MI, Stratford J, Thompson E, Dehn TC. Laparoscopic antireflux surgery in the treatment of the acid-sensitive oesophagus. Br J Surg 2001; 88:577-82. [PMID: 11298628 DOI: 10.1046/j.1365-2168.2001.01742.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
BACKGROUND Approximately 10 per cent of patients referred for 24-h oesophageal pH tests with symptoms suggestive of gastro-oesophageal reflux disease will have a normal endoscopic examination and normal distal oesophageal acid exposure times, but a clear temporal correlation between their symptoms and episodes of acid reflux. These patients have an 'acid-sensitive oesophagus', which forms part of the spectrum of reflux-related conditions. Their response to antireflux surgery has not been reported previously. This study represents a prospective cohort analysis of a clearly defined group of patients with acid-sensitive oesophagus who have undergone laparoscopic antireflux surgery. METHODS Nineteen patients (nine male and ten female; median age 32 years) underwent laparoscopic antireflux surgery for acid-sensitive oesophagus. All had had an incomplete response to medical therapy. RESULTS Eighteen of 19 patients were graded Visick I or II at 6 months after operation; all 16 patients followed for 1 year were graded Visick I or II. There were significant falls in DeMeester symptom score (4.0 versus 0.5; P < 0.001), symptom events (20 versus none; P < 0.001), number of reflux episodes (17 versus two; P < 0.001) and overall acid exposure times (1.2 versus 0.3 per cent; P < 0.001) after operation. CONCLUSION Laparoscopic antireflux surgery is a valid and effective treatment for patients with an acid-sensitive oesophagus. Presented in poster form to the British Society of Gastroenterology, Birmingham, March 2000 and the American Gastroenterological Association, San Diego, May 2000
Collapse
|
48
|
Preul MC, Feindel W, Dagi TF, Stratford J, Bertrand G. Arthur Roland Elvidge (1899-1985): contributions to the diagnosis of brain tumors and cerebrovascular disease. J Neurosurg 1998; 88:162-71. [PMID: 9420095 DOI: 10.3171/jns.1998.88.1.0162] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The contributions of Arthur Elvidge (1899-1985), Wilder Penfield's first neurosurgical recruit, to the development of neurosurgery have been relatively neglected, although his work in brain tumors extended the previous work of Percival Bailey and Harvey Cushing. He published rigorous correlations of clinical and histological information and formulated a revised, modern nosology for neuroepithelial tumors, including a modern histological definition of glioblastoma multiforme. Well ahead of his time, he believed that glioblastoma was not strictly localized and was the first to comment that the tumor frequently showed "satellitosis." He was the first neurosurgeon in North America to use angiography as a radiographic aid in the diagnosis of cerebrovascular disease. Having studied with Egas Moniz, he was the first to detail the use of angiographic examinations specifically for demonstrating cerebrovascular disorders, believing that it would make possible routine surgery of the intracranial blood vessels. Seeking to visualize all phases of angiography, he was the impetus behind the design of one of the first semi-automatic film changers. Elvidge and Egas Moniz made the first observations on thrombosis of the carotid vessels independently of each other. Elvidge elucidated the significance of embolic stroke and commented on the ischemic sequelae of subarachnoid hemorrhage. Besides his contributions to neurosurgery, he codiscovered the mode of transmission of poliomyelitis. Elvidge's soft-spoken manner, his dry wit and candor, mastery of the understatement, love of exotic travel, and consummate dedication to neurosurgery made him a favorite of patients, neurosurgery residents, nurses, and other hospital staff. His accomplishments and example as teacher and physician have become part of neurosurgery's growing legacy.
Collapse
|
49
|
Abstract
BACKGROUND A 20-year-old woman with a right occipital condylar fracture and bilateral hypoglossal nerve injury is presented. Only 17 cases of condylar fracture have been reported in the literature. METHODS The patient was evaluated with plain films, coronal and axial cut CT, and MRI. RESULTS MRI showed a severely distorted but otherwise normal medulla and a displaced condylar bone fragment. CONCLUSION Condylar fracture may cause twelfth nerve palsy by injuring the central or peripheral nerve.
Collapse
|
50
|
Stratford J, Wright MA, Reineke W, Mokross H, Havel J, Knowles CJ, Robinson GK. Influence of chlorobenzoates on the utilisation of chlorobiphenyls and chlorobenzoate mixtures by chlorobiphenyl/chlorobenzoate-mineralising hybrid bacterial strains. Arch Microbiol 1996; 165:213-8. [PMID: 8599540 DOI: 10.1007/bf01692864] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Chlorobenzoates (CBA) arise as intermediates during the degradation of polychlorinated biphenyls (PCBs) and some chlorinated herbicides. Since PCBs were produced as complex mixtures, a range of mono-, di-, and possibly trichloro-substituted benzoates would be formed. Chlorobenzoate degradation has been proposed to be one of the rate-limiting steps in the overall PCB-degradation process. Three hybrid bacteria constructed to have the ability to completely mineralise 2-, 3-, or 4-monochlorobiphenyl respectively, have been studied to establish the range of mono- and diCBAs that can be utilised. The three strains were able to mineralise one or more of the following CBAs: 2-, 3-, and 4-monochlorobenzoate and 3,5-dichlorobenzoate. No utilisation of 2,3-, 2,5-, 2,6-, or 3,4-diCBA was observed, and only a low concentration (0.11 mM) of 2,4-diCBA was mineralised. When the strain with the widest substrate range (Burkholderia cepacia JHR22) was simultaneously supplied with two CBAs, one that it could utilise plus one that it was unable to utilise, inhibitory effects were observed. The utilisation of 2-CBA (2.5 mM) by this strain was inhibited by 2,3-CBA (200 microM) and 3,4-CBA (50 microM). Although 2,5-cba and 2,6-cba were not utilised as carbon sources by strain jhr22, they did not inhibit 2-cba utilisation at the concentrations studied, whereas 2,4-cba was co-metabolised with 2-cba. The utilisation of 2-, 3-, and 4-chlorobiphenyl by strain JHR22 was also inhibited by the presence of 2,3- or 3,4-diCBA. We conclude that the effect of the formation of toxic intermediates is an important consideration when designing remediation strategies.
Collapse
|