26
|
Santos Filho E, Saijo Y, Tanaka A, Yambe T, Yoshizawa M. Fractal dimension of 40 MHz intravascular ultrasound radio frequency signals. ULTRASONICS 2008; 48:35-39. [PMID: 18078666 DOI: 10.1016/j.ultras.2007.08.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2007] [Revised: 08/24/2007] [Accepted: 08/24/2007] [Indexed: 05/25/2023]
Abstract
OBJECTIVE Fully automatic tissue characterization in intravascular ultrasound systems is still a challenge for the researchers. The present work aims to evaluate the feasibility of using the Higuchi fractal dimension of intravascular ultrasound radio frequency signals as a feature for tissue characterization. METHODS Fractal dimension images are generated based on the radio frequency signals obtained using mechanically rotating 40 MHz intravascular ultrasound catheter (Atlantis SR Plus, Boston Scientific, USA) and compared with the corresponding correlation images. CONCLUSION An inverse relation between the fractal dimension images and the correlation images was revealed indicating that the hard or slow moving tissues in the correlation image usually have low fractal dimension and vice-versa. Thus, the present study suggests that fractal dimension images may be used as a feature for intravascular ultrasound tissue characterization and present better resolution then the correlation images.
Collapse
|
27
|
Shiraishi Y, Yambe T, Saijo Y, Sato F, Tanaka A, Yoshizawa M, Ogawa D, Wada Y, Itoh S, Sakata R, Park Y, Uematsu M, Umezu M, Fujimoto T, Masumoto N, Liu H, Baba A, Konno S, Nitta S, Imachi K, Tabayashi K, Sasada H, Homma D. Morphological Approach for the Functional Improvement of an Artificial Myocardial Assist Device using Shape Memory Alloy Fibres. ACTA ACUST UNITED AC 2007; 2007:3974-7. [DOI: 10.1109/iembs.2007.4353204] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
28
|
Shiraishi Y, Yambe T, Sekine K, Saijo Y, Wang Q, Liu H, Nitta S, Konno S, Masumoto N, Nagatoshi J, Itoh S, Park Y, Uematsu M, Umezu M, Ogawa D, Olegario P, Sato F, Yoshizawa M, Tanaka A, Tabayashi K, Sasada H, Fujimoto T, Homma D, Higa M, Hori Y. Development of an Artificial Myocardium using a Covalent Shape-memory Alloy Fiber and its Cardiovascular Diagnostic Response. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2007; 2006:406-8. [PMID: 17282200 DOI: 10.1109/iembs.2005.1616431] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The authors have been developing a newly-designed totally-implantable artificial myocardium using a covalent shape-memory alloy fibre (Biometal®, Toki Corporation), which is attached onto the ventricular wall and is also capable of supporting the natural ventricular contraction. This mechanical system consists of a contraction assistive device, which is made of Ti-Ni alloy. And the phenomenon of the martensitic transformation of the alloy was employed to achieve the physiologic motion of the device. The diameter of the alloy wire could be selected from 45 to 250μm. In this study, the basic characteristics of the fiber of 150μm was examined to design the sophisticated mechano-electric myocardium. The stress generated by the fiber was 400gf under the pulsatile driving condition (0.4W, 1Hz). Therefore it was indicated that the effective assistance might be achieved by using the Biometal shape-memory alloy fiber.
Collapse
|
29
|
Uematsu M, Shiraishi Y, Sekine K, Yambe T, Saijo Y, Park Y, Ando H, Matsumoto T, Takeda S, Iwasaki K, Umezu M. An innovative approach to evaluate a cardiac function based on surface measurement. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2007; 2005:7640-3. [PMID: 17282050 DOI: 10.1109/iembs.2005.1616281] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Major function of the heart is to pump blood flow up to all tissues or organs in the body, and it is generally recognized that cardiac function under various diseased conditions are mainly represented by a relationship between blood flow and pressure inside of the heart. In this report, an original proposal of evaluation method on cardiac function is introduced through a simultaneous measurement of various points of cardiac muscular surface. An optical three-dimensional location sensor was employed to measure a displacement change of anatomically specific points on heart surface. Then, changes in strain in each regional surface area were quantitatively obtained. This result indicated similar tendency obtained from echocardiogram. It was also indicated that there was a difference in displacements and phrases between control and arrhythmia. Moreover, strain change in regional area was coincident with a contraction of natural heart. It was found that an attempt to superimpose the data of strain change onto the video images of natural heart was extremely helpful to understand a cardiac function visually.
Collapse
|
30
|
Olegario P, Yoshizawa M, Tanaka A, Shiraishi Y, Ogawa D, Hanaoka T, Abe K, Yambe T, Nitta S. Dynamic response of the pulmonary circulation in continuous flow artificial heart systems. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2007; 2004:3777-80. [PMID: 17271117 DOI: 10.1109/iembs.2004.1404059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Pulmonary circulation dynamics is important when considering bi-ventricular assist devices (BiVAD) or total artificial heart (TAH) systems and in investigating the mechanism of atrial collapse in order to design better control algorithms. In this study, we investigated pulmonary circulation dynamics in a continuous flow artificial heart system by performing acute tests on a mature goat. By varying the right pump speed, we were able to observe the dynamic response of the left atrial pressure (LAP) and simulate conditions that result in atrial suction. The results showed a time constant characteristic of a compliance lag in LAP response to changes in right pump output in the TAH configuration. These results may prove useful in the design of a new mock circulatory system that incorporates the dynamics of the pulmonary circulation, and in the improvement of existing control algorithms that prevent atrial wall collapse.
Collapse
|
31
|
Sugita N, Yoshizawa M, Tanaka A, Abe K, Chiba S, Yambe T, Nitta S. Quantitative evaluation of the effect of visually-induced motion sickness using causal coherence function between blood pressure and heart rate. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2007; 2004:2407-10. [PMID: 17270756 DOI: 10.1109/iembs.2004.1403696] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
To evaluate the effect of visually-induced motion sickness on the human, blood pressure variability (BP) and heart rate variability (HR) of 51 normal subjects watching a 15min-long video image taken by a vibrating handy camera were analyzed. Not only coherence function (K/sup 2/) between BP and HR but also two causal coherence functions: K/sup 2//sub BP-->HR/ from BP to HR and K/sup 2//sub HR-->BP/ from HR to BP were introduced to divide causal linearity of the cardiovascular system regarded as a closed-loop system. K/sup 2/ represents total linearity of the system. K/sup 2//sub BP-->HR/ and K/sup 2//sub HR-->BP/ correspond to the baroreflex system and the mechanical hemodynamics, respectively. The results revealed that K/sup 2//sub BP-->HR/ at the Mayer wave-band (around 0.1 Hz) of the subjects prone to motion sickness decreased gradually and was significantly lower than that of the subjects not prone to in later scenes. This result has never been obtained from conventional methods dealing with a cardiovascular system as an open-loop system.
Collapse
|
32
|
Mitamura Y, Yambe T, Sekine K. A MAGNETICALLY SEALED, HYDRODYNAMICALLY SUSPENDED MECHANICALLY NON-CONTACT AXIAL FLOW BLOOD PUMP. ASAIO J 2006. [DOI: 10.1097/00002480-200603000-00106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
33
|
Funamoto K, Hayase T, Saijo Y, Yambe T. Improvement of accuracy of blood flow simulation by integrating measurement using ultrasonic Doppler method. J Biomech 2006. [DOI: 10.1016/s0021-9290(06)85545-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
34
|
Yambe T, Inoue A, Sekine K, Shiraishi Y, Watanabe M, Yamaguchi T, Shibata M, Maruyama M, Konno S, Nitta S. Effect of the alternative magnetic stimulation on peripheral circulation for regenerative medicine. Biomed Pharmacother 2005; 59 Suppl 1:S174-6. [PMID: 16275489 DOI: 10.1016/s0753-3322(05)80027-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Regenerative medicine for patients with peripheral atherosclerosis attracts considerable attention around the world. However, ethical problems persist in gene therapy. This study evaluates the effect of alterative magnetic stimulation on peripheral circulation. The effect of magnetic stimulation as a medical treatment was examined using a thermograph for 11 healthy volunteers. The thermograph was used to measure the rise in skin temperature. The experimental results suggested an improvement in the peripheral circulation. The results of our study suggest the effectiveness of alternative magnetic stimulation on atherosclerosis. We intend to extend our study in order to establish a methodology for regenerative medical treatment for patients with peripheral atherosclerosis. Further, we wish to advance the current research in the field of angiogenesis.
Collapse
|
35
|
Yambe T, Meng X, Hou X, Wang Q, Sekine K, Shiraishi Y, Watanabe M, Yamaguchi T, Shibata M, Kuwayama T, Maruyama M, Konno S, Nitta S. Cardio-ankle vascular index (CAVI) for the monitoring of the atherosclerosis after heart transplantation. Biomed Pharmacother 2005; 59 Suppl 1:S177-9. [PMID: 16275490 DOI: 10.1016/s0753-3322(05)80028-9] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Atherosclerosis has been reported to progress rapidly after heart transplantation. A quantitative diagnosis is required for the diagnosis of atherosclerosis after heart transplantation. In this study, we compared brachial-ankle pulse wave velocity (baPWV) and cardio-ankle vascular index (CAVI) for the diagnosis. The average values of both baPWV and CAVI in the seven cases after heart transplantation were found to be signif-icantly large in comparison to the average values of the normal healthy people of the same age group. When comparisons were made before and after the heart transplantation in a particular case, CAVI was stable and baPWV changed sharply. A lot of parameters such as blood pressure, blood volume, etc. have been reported to influence baPWV. The results of this study suggested that CAVI was a stable parameter in comparison to baPWV even after heart transplantation. Thus, CAVI may be useful in the diagnosis of arteriosclerosis after heart transplantation.
Collapse
|
36
|
Yambe T, Asano E, Mauyama S, Shiraishi Y, Shibata M, Sekine K, Watanabe M, Yamaguchi T, Kuwayama T, Konno S, Nitta S. Chaos analysis of electro encephalography and control of seizure attack of epilepsy patients. Biomed Pharmacother 2005; 59 Suppl 1:S236-8. [PMID: 16275501 DOI: 10.1016/s0753-3322(05)80038-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
Abstract
In order to evaluate the EEG of patients with epilepsy, chaos analysis was performed for the subdural EEG time series data. The chaos attractor was reconstructed in the phase space and the correlation dimension. KS entropy calculated from the Lyapunov exponents was evaluated. Before the seizure attack, the KS entropy showed a lower value when compared with the time series data recorded during healthy condition. The results of our study suggest that it is possible to predict the seizure attack by the chaos analysis of the EEG signal. Further, we aim at developing an automatic control system for predicting a seizure attack by the use of local cooling of the focus with Peltier elements.
Collapse
|
37
|
Kawano S, Isoyama T, Kobayashi S, Arai H, Takiura K, Saito I, Chinzei T, Abe Y, Yambe T, Nitta S, Imachi K, Hashimoto H. Miniature vibrating flow blood pump using a cross-slider mechanism for external shunt catheter. Artif Organs 2003; 27:73-7. [PMID: 12534716 DOI: 10.1046/j.1525-1594.2003.07186.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The prototype of the miniature vibrating flow pump (VFP) is developed for the external shunt catheter. The cross-slider mechanism is applied to vibrate the tube, which causes the pumping effect. This mechanism results in successful development of the miniature and lightweight VFP. By the use of the prototype VFP, the experiment of the basic pump performance is made in detail based on the authorized procedure in the research field of fluids engineering. The typical H-Q curve of VFP, which is the relationship between the pump head and the flow rate, can be obtained. This result suggests that the miniature VFP developed here can be expected to be used as the booster pump for the external shunt catheter in clinical applications.
Collapse
|
38
|
Yambe T, Yoshizawa M, Taira R, Tanaka A, Iguchi A, Tabayashi K, Tobita S, Nitta S. Fluctuations of Emax of the left ventricle: effect of atrial natriuretic polypeptide. Biomed Pharmacother 2002; 55 Suppl 1:147s-152s. [PMID: 11774863 DOI: 10.1016/s0753-3322(01)90021-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
Abstract
Recently the circadian rhythm of fluctuations in heart rate variability (HRV) has gained increasing attention, and the use of appropriate treatment corresponding to the circadian rhythm has become an important issue. However, the question has been raised as to whether the rhythm of fluctuation is only limited to HRV, and if a rhythm is also present in the contraction of the heart. The mathematical technique of electrical circuit simulation of the cardiovascular system was used to observe the Emax rhythm. In this study, the therapeutic effect of various drugs, including atrial natriuretic polypeptide (ANP), was confirmed. The effect of inotropic drugs including ANP on Emax was observed, and the results based on an old and a new method of determining Emax . were examined. Furthermore, the chaos analysis of Emax was also made. The time series of Emax showed an increased complexity due to the administration of ANP. In conclusion, it might be important to consider not only the fluctuation of HRV, but also an analysis of the fluctuation in the contraction of the heart.
Collapse
|
39
|
Shizuka K, Yambe T. [Relationship between depression and lipid metabolism in the elderly with hypertension]. Nihon Ronen Igakkai Zasshi 2001; 38:785-90. [PMID: 11774724 DOI: 10.3143/geriatrics.38.785] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In order to examine the relationship between depressive symptoms and the lipid metabolism in the elderly with hypertension, we recruited 311 outpatients aged 65 or older with hypertension and defined depression as patients with 6 or more symptoms on Geriatric Depression Scale short form. We further classified depressed patients into three groups: mild depressed with 6-7 symptoms, moderate depressed with 8-10 symptoms and severe depressed with 11 or more symptoms. Serum total cholesterol, serum HDL cholesterol and serum LDL cholesterol levels were significantly higher in female depressed patients than those in nondepressed patients (TC, 194.6 +/- 30.1 vs 208.0 +/- 32.8 p < 0.01; HDL, 67.3 +/- 19.3 vs 72.3 +/- 16.2 p < 0.01; LDL, 107.6 +/- 26.5 vs 116.0 +/- 29.1 p < 0.05). In male patients, serum lipids were not significantly associated with depressive symptoms but depressed patients were significantly older than nondepressed patients (75.3 +/- 6.2 vs 78.0 +/- 5.9 p < 0.05). Concerning the analysis of the severity of depression, serum total cholesterol and serum LDL cholesterol levels were significantly higher in mildly depressed patients than nondepressed patients in females and the same tendency was seen in male patients. No linear associations were shown between the severity of depression and serum lipids. We concluded that hyperlipidemia may be associated with depressive symptoms in elder patients with hypertension and that it might be related the severity of depression. We need to further investigate the relationship between depression and lipid metabolism in larger population samples.
Collapse
|
40
|
Wang XZ, Yoshizawa M, Tanaka A, Abe KI, Yambe T, Nitta S, Chinzei T, Abe Y, Imachi K. Automatic monitoring system for artificial hearts using self organizing map. ASAIO J 2001; 47:686-91. [PMID: 11730212 DOI: 10.1097/00002480-200111000-00023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
This study presents an automatic monitoring system for artificial hearts. The self organizing map (SOM) was applied to monitoring and analysis of an aortic pressure (AoP) signal measured from an adult goat equipped with a total artificial heart. In the proposed system, two different SOMs were used to detect and classify abnormalities in the measured AoP signal. In the first stage, an ordinary SOM, taught with only normal AoP data, was used for detection of abnormalities on the basis of the quantization error in the real-time monitoring task. In the second stage, a supervised SOM was used for classification of abnormalities. The supervised SOM can be regarded as an ordinary SOM with an extra class vector for solving the classification problem. The class vector is assigned to every node in the second SOM as an output weight learned according to Kohonen's learning rule. The effectiveness of detection and classification of abnormalities using these two SOMs was confirmed.
Collapse
|
41
|
Yambe T, Kobayashi SI, Yoshizawa M, Tanaka A, Matsuki H, Sato F, Tabayashi K, Nitta SI. Recent progress on the vibrating flow pump as a totally implantable ventricular assist device. Artif Organs 2001; 25:688-91. [PMID: 11722343 DOI: 10.1046/j.1525-1594.2001.06857.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
This study describes the present state of progress in the development of the vibrating flow pump (VFP) ventricular assist system. We have proceeded with development aiming at a totally implantable ventricular assist system with smaller size and lighter weight appropriate for Asians like the Japanese by increasing the drive frequency. An actuator is important for the development of the miniature sized and lightweight artificial heart. We applied a linear motor for the mechanical part at first. The step motor was applied after that. This form may be best if we want the lightweight small sized motor for an actuator. The cross slider form is applied at present. It succeeded in the miniaturization compared with the linear motor. In the VFP-type ventricular assist system, the blood contact parts are a central vibration tube with inflow and outflow chambers. We designed round diaphragms to prevent thrombus formation. In addition, we developed an energy transmission system for total implantation. The VFP creates a high frequency oscillated blood flow. It has a unique flow pattern. Brain blood flow increased although the total flow of the circulation did not change in the frequency of 25 to 30 Hz. The quantitative evaluation of the autonomic nerve function during the left heart assistance with an oscillated blood flow was carried out by spectral analysis. Some influences on an autonomic nerve were observed by the VFP left heart assistance. We will continue development research with the aim of clinical application.
Collapse
|
42
|
Amae S, Wada M, Luo Y, Nakamura H, Yoshida S, Kamiyama T, Yambe T, Takagi T, Nitta S, Ohi R. Development of an implantable artificial anal sphincter by the use of the shape memory alloy. ASAIO J 2001; 47:346-50. [PMID: 11482484 DOI: 10.1097/00002480-200107000-00010] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
In this study, we developed and assessed an artificial anal sphincter driven by an shape memory alloy actuator (AS-SMA). The performance characteristics of the device were analyzed with a measurement system. Assessment showed that the AS-SMA could generate a pressure of 55 mm Hg at an atmospheric temperature of 36 degrees C, and displacement of the SMA actuator was 7.5 mm when the temperature of the SMA plate was 55 degrees C. To evaluate opening and closing, we studied a piglet colostomy model, in which the AS-SMA was implanted around the colostomy in the extraperitoneal space. Flow control tests using living porcine intestine revealed that the AS-SMA could maintain fecal continence against an intestinal pressure of 75 mm Hg. The high pressure zone corresponding to the location of the device was demonstrated in a manometric examination. For 6 days after surgery, we activated the AS-SMA twice a day and observed the bowel movements. The animal experiment indicated that the AS-SMA is able to control the bowel movements of patients with fecal incontinence if several problems, such as burning of tissue around the device and compression injury of the intestine, are resolved.
Collapse
|
43
|
Shibata M, Shizuka K, Nanka S, Yambe T, Nitta S. LONG-TERM RECORDING OF THE VAGUS NERVE ACTIVITIES. ASAIO J 2001. [DOI: 10.1097/00002480-200103000-00095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
44
|
Wang XZ, Yoshizawa M, Tanaka A, Abe K, Yambe T, Nitta S. Automatic detection and classification of abnormalities for artificial hearts using a hierarchical self-organizing map. Artif Organs 2001; 25:150-3. [PMID: 11251481 DOI: 10.1046/j.1525-1594.2001.06544-2.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
A hierarchical self-organizing map (SOM) has been developed for automatic detection and classification of abnormalities for artificial hearts. The hierarchical SOM has been applied to the monitoring and analysis of an aortic pressure (AoP) signal measured from an adult goat equipped with a total artificial heart. The architecture of the network actually consists of 2 different SOMs. The first SOM clusters the AoP beat patterns in an unsupervised way. Afterward, the outputs of the first SOM combined with the original time-domain features of beat-to-beat data are fed to the second SOM for final classification. Each input vector of the second SOM is associated with a class vector. This class vector is assigned to every node in the second map as an output weight and learned according to Kohonen's learning rule. Some experimental results revealed that a certain abnormality caused by breakage of sensors could be identified and detected correctly and that the change in the state of the circulatory system could be recognized and predicted to some extent.
Collapse
|
45
|
Yambe T, Owada N, Kobayashi SI, Tanaka A, Yoshizawa M, Abe KI, Tabayashi K, Takeda H, Hashimoto H, Nitta SI. Totally implantable ventricular assist system that can increase brain blood flow. Artif Organs 2000; 24:644-7. [PMID: 10971254 DOI: 10.1046/j.1525-1594.2000.06608.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
In the clinical usage of the ventricular assist device (VAD), multiple organ failure becomes an important problem. To improve the clinical record of the VAD, another organ function may be vitally important. For that reason, we have been developing a VAD system aiming at improving another organ's function. Development of the vibrating flow pump (VFP), which can generate a very unique flow pattern from 10 Hz to 50 Hz, was ongoing in our Institute. In order to evaluate brain blood flow and oxygen consumption, HbO2 was measured with a NIRO monitoring device in healthy adult goats. Four goats were anesthetized with halothane inhalation; then left thoracotomy was performed for the left heart bypass. HbO2 of the brain was measured by recording of the hemodynamic variables during left heart assistance with the VFP system. During left heart bypass with the VFP system, hemodynamic parameters stayed within normal range, and satisfactory pump output was easily obtained. Pump output stayed within 20-40% bypass to evaluate the effect of high frequency oscillated assist flow on brain blood flow during the same cardiac output. Interesting results were observed during the experiments. During 30 Hz drive of the VFP left heart assistance, HbO2 suggested that brain blood flow significantly increased compared with another drive frequency assistance during the same total cardiac output. These results suggest that we can control the brain blood flow with a totally implantable VAD system such as the VFP system.
Collapse
|
46
|
Shizuka K, Yambe T, Fukudo S, Nitta S. [Type A behaviour pattern and hypercholesterolemia in elder patients]. Nihon Ronen Igakkai Zasshi 2000; 37:486-9. [PMID: 10998931 DOI: 10.3143/geriatrics.37.486] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
To examine the relationship between type A behavior pattern and hypercholesterolemia, we recruited 109 primary hypercholesterolemic patients without treatment for hyperlipidemia (30 males and 79 females) and then classified them according to Maeda's questionnaire into two groups; type A group (16 males and 35 females, aged 73.1 +/- 8.7) and type B group (14 males and 44 females, aged 71.3 +/- 8.7). We studied serum total cholesterol, serum triglyceride and BMI. Serum total cholesterol was shown significantly higher in type A group than that in type B (233.0 +/- 22.8 vs 223.9 +/- 14.2 p < 0.01) and BMI lower (24.0 +/- 3.9 vs 25.4 +/- 3.9 p < 0.05), however, there was no significant difference in serum triglyceride between two groups (148.96 +/- 8.2 vs 134.0 +/- 48.8). Although there was no significant difference in BMI, serum total cholesterol was significantly higher in the women's group and in the 60s. This study suggests that type A behavior pattern is related to lipid metabolism, however we should take gender and age into consideration to study the relationship between type A behavior pattern and lipid metabolism.
Collapse
|
47
|
Yambe T, Amae S, Takagi H, Kamiyama T, Luo Y, Nitta S. DEVELOPMENT OF AN IMPLANTABLE ARTIFICIAL ANAL SPHINCTER BY THE USE OF THE SHAPE MEMORY ALLOY. ASAIO J 2000. [DOI: 10.1097/00002480-200003000-00313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
48
|
Saijo Y, Okawai H, Sasaki H, Yambe T, Nitta S, Tanaka M, Kobayashi K, Honda Y. Evaluation of the inner-surface morphology of an artificial heart by acoustic microscopy. Artif Organs 2000; 24:64-9. [PMID: 10677159 DOI: 10.1046/j.1525-1594.2000.06349.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The total artificial heart (TAH) is being developed for permanent replacement of the natural heart instead of heart transplantation. The need for detecting the material fatigue in the TAH is increasing in order to guarantee long-term use. In this study, the inner surface morphology of the TAH was evaluated by a specially developed scanning acoustic microscope (SAM) system operating in the frequency range of 100-200 MHz. The inner sac of our TAH consisted of polyvinylchloride coated with polyurethane, and the SAM investigations were performed before and after the implantations in goats. The amplitude images of the SAM demonstrated protein adhesion on the inner surface of the TAH after the animal experiment, and the phase images showed distortion of the wall with spatial resolution of 0.2 microm. These results suggest the feasibility of a high-frequency ultrasound for evaluating the material fatigue of TAH.
Collapse
|
49
|
Kobayashi S, Owada N, Yambe T, Nitta S, Fukuju T, Hongoh T, Hashimoto H. Total vascular resistance and blood flow frequency during left ventricular assistance using a vibrating flow pump. Artif Organs 1999; 23:732-5. [PMID: 10463498 DOI: 10.1046/j.1525-1594.1999.06412.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
A vibrating flow pump (VFP) can generate high frequency oscillated blood flow within 10-30 Hz by the oscillation of its central tube. A totally implantable artificial heart using a VFP is being developed as a unique type of blood pump. In this study, left ventricular (LV) assist circulation was performed using a VFP. The total vascular resistance and driving frequency of the VFP were estimated from their relationship. The effect of oscillation on the vascular system was studied by the frequency analysis method and vascular impedance. Adult goats were anesthetized by halothane using an inhaler and a left fourth thoracotomy was performed. The inflow cannula was inserted into the left ventricle, and the outflow cannula was sutured to the descending aorta. The VFP and a centrifugal pump were set in parallel for alternation and comparison. The driving frequency of the VFP was changed and included 15, 20, 25, and 30 Hz. The hemodynamic parameters were continuously recorded during experiments by a digital audio tape (DAT) data recorder. The internal pressure of the left ventricular cavity and aortic pressure were monitored by the pressure manometers continuously. One hundred percent LV assistance was judged by the separation of LV and aortic pressure. The total vascular resistance was decreased by the start of operation of each pump. The decrease during flow using the VFP was not as large as that using a centrifugal pump (CP). The arterial input impedance during oscillated blood flow by the VFP showed a slow curve appearance. It was similar to the frequency characteristics curve of natural heart beats within the lower frequencies. The study of arterial impedance may be important for the estimation of the reflection of the pulsatile wave from the arterial branch, among other things.
Collapse
|
50
|
Yambe T, Nanka S, Kobayashi S, Tanaka A, Owada N, Yoshizawa M, Abe K, Tabayashi K, Takeda H, Nishihira T, Nitta S. Detection of the cardiac function by fractal dimension analysis. Artif Organs 1999; 23:751-6. [PMID: 10463502 DOI: 10.1046/j.1525-1594.1999.06416.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Nonlinearity in circulation control attracts attention because nonlinearity is thought to be essential in the function of the living body. Many investigators have pointed out that the analysis of heart rate variability in particular is important in the analysis of autonomic nerve and cardiac function evaluation. Heart rate variability shows nonlinear behavior. However, until the present, many reports have been premised on linearity; linear correlation by frequency analysis has been used by many studies. However, in terms of this methodology, there is a problem applying it to the nonlinear living body. Therefore, fractal and chaos methodology has been used. The ascertainment of cardiac function has become important in allowing the clinical stage of a ventricular assist system to be successful. The purpose of this study was cardiac function evaluation by a methodology that was premised on nonlinearity. Chaos and fractal theory was used as a nonlinear dynamic theory. As a methodology of measurement, the volume of the left ventricle was used rather than an electrocardiogram, the waveform of arterial blood pressure. The volume was measured using acoustic quantification (AQ) ultrasonic echocardiography. Using these methodologies, the time series of many patients were analyzed. For example, drug administration was attempted in this study, and it was found that some drugs like ACE inhibitors showed a significant effect upon nonlinear dynamics in the cardiovascular system. The result, which attempted cardiac function evaluation by these various methodologies, is reported.
Collapse
|