26
|
Wiśniewski K, Tomasik B, Tyfa Z, Reorowicz P, Bobeff EJ, Stefańczyk L, Posmyk BJ, Jóźwik K, Jaskólski DJ. Porous Media Computational Fluid Dynamics and the Role of the First Coil in the Embolization of Ruptured Intracranial Aneurysms. J Clin Med 2021; 10:jcm10071348. [PMID: 33805169 PMCID: PMC8037793 DOI: 10.3390/jcm10071348] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 02/28/2021] [Accepted: 03/20/2021] [Indexed: 11/22/2022] Open
Abstract
Background: The objective of our project was to identify a late recanalization predictor in ruptured intracranial aneurysms treated with coil embolization. This goal was achieved by means of a statistical analysis followed by a computational fluid dynamics (CFD) with porous media modelling approach. Porous media CFD simulated the hemodynamics within the aneurysmal dome after coiling. Methods: Firstly, a retrospective single center analysis of 66 aneurysmal subarachnoid hemorrhage patients was conducted. The authors assessed morphometric parameters, packing density, first coil volume packing density (1st VPD) and recanalization rate on digital subtraction angiograms (DSA). The effectiveness of initial endovascular treatment was visually determined using the modified Raymond–Roy classification directly after the embolization and in a 6- and 12-month follow-up DSA. In the next step, a comparison between porous media CFD analyses and our statistical results was performed. A geometry used during numerical simulations based on a patient-specific anatomy, where the aneurysm dome was modelled as a separate, porous domain. To evaluate hemodynamic changes, CFD was utilized for a control case (without any porosity) and for a wide range of porosities that resembled 1–30% of VPD. Numerical analyses were performed in Ansys CFX solver. Results: A multivariate analysis showed that 1st VPD affected the late recanalization rate (p < 0.001). Its value was significantly greater in all patients without recanalization (p < 0.001). Receiver operating characteristic curves governed by the univariate analysis showed that the model for late recanalization prediction based on 1st VPD (AUC 0.94 (95%CI: 0.86–1.00) is the most important predictor of late recanalization (p < 0.001). A cut-off point of 10.56% (sensitivity—0.722; specificity—0.979) was confirmed as optimal in a computational fluid dynamics analysis. The CFD results indicate that pressure at the aneurysm wall and residual flow volume (blood volume with mean fluid velocity > 0.01 m/s) within the aneurysmal dome tended to asymptotically decrease when VPD exceeded 10%. Conclusions: High 1st VPD decreases the late recanalization rate in ruptured intracranial aneurysms treated with coil embolization (according to our statistical results > 10.56%). We present an easy intraoperatively calculable predictor which has the potential to be used in clinical practice as a tip to improve clinical outcomes.
Collapse
|
27
|
Hsiang HI, Chuang KH, Lee WH. FeSiCr Alloy Powder to Carbonyl Iron Powder Mixing Ratio Effects on the Magnetic Properties of the Iron-Based Alloy Powder Cores Prepared Using Screen Printing. MATERIALS (BASEL, SWITZERLAND) 2021; 14:1034. [PMID: 33671680 PMCID: PMC7926424 DOI: 10.3390/ma14041034] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/02/2021] [Revised: 01/25/2021] [Accepted: 02/16/2021] [Indexed: 11/16/2022]
Abstract
A screen printing process was used to substitute dry molding to solve the uneven compaction problem in the coil center column during molding in this study. FeSiCr alloy powders (FSC) with a large particle size were mixed with fine spherical carbonyl iron powder to increase the compaction density. FSC to carbonyl iron powder (CIP) mixing ratio effects on magnetic paste rheological behaviors and magnetic properties of the molding coil prepared using screen printing were investigated. A magnetic paste with the lowest viscosity can be obtained using 3C7F (30% CIP + 70% FSC) due to the small-sized CIP adsorbed onto the FSC surface. This process reduces the interlocked network formation resulting from the CIP. The toroidal core with 3C7F exhibited the highest relative density and highest inductance. The coils with pure CIP and higher CIP content exhibited the better DC superposition characteristic. The toroidal core loss increased rapidly as the FSC content was increased. A proper trade-off between the inductance, DC-bias superposition characteristic, and magnetic core loss can be reached by choosing a suitable powder mixing ratio.
Collapse
|
28
|
Zhou Y, Peng Q, Wu X, Zhang Y, Liu J, Yang X, Mu S. Endovascular Treatment of Tiny Aneurysms With Low-Profile Visualized Intraluminal Support Devices Using a "Compressed" Stent Technique. Front Neurol 2021; 11:610126. [PMID: 33391169 PMCID: PMC7775541 DOI: 10.3389/fneur.2020.610126] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Accepted: 12/02/2020] [Indexed: 11/13/2022] Open
Abstract
Objective: To investigate the safety and efficacy of low-profile visualized intraluminal support (LVIS) stent-assisted coiling of intracranial tiny aneurysms using a "compressed" stent technique. Methods: We retrospectively analyzed patients with tiny aneurysms treated in our hospital with LVIS devices using a compressed stent technique. We analyzed patients' imaging outcomes, clinical outcomes, and complications. Results: Forty-two tiny aneurysms in 42 patients were included in this study cohort; 8 patients presented with subarachnoid hemorrhage at admission. The immediate postoperative complete embolization rate was 76.2% (32/42). After an average of 8.5 months of imaging follow-up, the complete embolization rate was 90.5% (38/42), and no aneurysm recanalization occurred. After an average of 24.4 months of clinical follow-up, 95.2% (40/42) of the patients achieved favorable clinical outcomes (modified Rankin scale = 0/1). Operation-related complications occurred in two patients (4.8%); one intraoperative acute thrombosis, and one significant unilateral decreased vision during the postoperative follow-up. Conclusion: LVIS stent-assisted coiling of intracranial tiny aneurysms using a compressed stent technique is safe and effective. Combined stent compression technology is beneficial to maximize the complete embolization of aneurysms and reduce aneurysm recanalization. This study expands the clinical applicability of LVIS stents.
Collapse
|
29
|
Chernyavsky MA, Mosoyan MS, Odintsov NS, Susanin NV, Kazantsev AN. [Embolization of arteriovenous malformation of the scrotum]. Khirurgiia (Mosk) 2021:118-121. [PMID: 34941219 DOI: 10.17116/hirurgia2021121118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The authors report a rare disease at the junction of urology and cardiovascular surgery (arteriovenous malformation (AVM) of the scrotum). The options for correction of this disease are discussed. The authors describe the complications of natural course of disease and their treatment. Treatment strategy with AVM embolization is substantiated. Postoperative regression of symptoms is emphasized. The authors concluded safety and effectiveness of interventional correction of this disease.
Collapse
|
30
|
Papakonstantinou NA, Samiotis I, Kratimenos T, Dedeilias P. Aortocoronary saphenous vein graft aneurysm misdiagnosed as aortic arch aneurysm. Ann Card Anaesth 2021; 24:247-249. [PMID: 33884987 PMCID: PMC8253034 DOI: 10.4103/aca.aca_74_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
Coronary artery bypass grafting is the mainstay of revascularization worldwide. However, the most widely used saphenous vein grafts are related to a number of late sequelae. Aortocoronary saphenous vein graft aneurysms mainly diagnosed incidentally are one of these complications. Although rare, given the fatal risk of rupture if left untreated, management either with percutaneous intervention or open redo surgery should be considered. However, no guidelines are established in current scarce literature. Hereby, we present the successful percutaneous management of a huge saphenous vein graft aneurysm via coiling, avoiding the risks of repeat sternotomy.
Collapse
|
31
|
Al-Abdulwahhab AH, Al-Suhibani S, Al-Sharydah AM, Al-Jubran SA, Al-Thuneyyan MA. Multiple Dural Arteriovenous Fistulas Manifesting as Progressive Otalgia and Tinnitus and Treated Using a Single Session of Endovascular Embolization. Clin Interv Aging 2020; 15:2313-2320. [PMID: 33335390 PMCID: PMC7737546 DOI: 10.2147/cia.s277762] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Accepted: 11/23/2020] [Indexed: 11/23/2022] Open
Abstract
Background Multiple cranial dural arteriovenous fistulas (dAVFs) are considered to be an uncommon vascular condition. dAVFs usually manifest with vague symptoms, which are related to the site of occurrence of the lesion and present with complex angio-architectural features, which in turn can render treatment procedures difficult. Appropriate treatment that aims to reduce the risk of intracranial bleeding and manage the patient’s symptoms requires a multidisciplinary approach. Case Presentation The patient was a 62-year-old man who developed symptoms of progressive right-sided otalgia and tinnitus. Cross-sectional imaging revealed long-standing venous congestion with intracranial hemorrhage in the right parieto-occipital region. Moreover, cerebral angiography demonstrated multiple complex dAVFs at the right transverse sinus-sigmoid sinus (TS-SS) junction, right posterior condylar confluence (PCC), and torcula. Treatment consisted of one session of endovascular treatment, in which transarterial Onyx embolization was used to treat the dVAF at the right TS-SS junction, transvenous coil embolization for the dVAF at the right PCC, and particle embolization for both occipital arteries feeding the torcular dAVF. Postoperative improvement with favorable clinical outcomes was observed at the patient’s last follow-up visit. Conclusion Multiple cranial dAVFs are an uncommon vascular lesion, which can present with unusual symptoms such as otalgia. Moreover, a single session of endovascular therapy can treat this lesion, ie, it can improve the patient’s symptoms and provide a beneficial long-term outcome.
Collapse
|
32
|
Zhou Y, Wu X, Tian Z, Yang X, Mu S. Pipeline Embolization Device With Adjunctive Coils for the Treatment of Unruptured Large or Giant Vertebrobasilar Aneurysms: A Single-Center Experience. Front Neurol 2020; 11:522583. [PMID: 33192964 PMCID: PMC7661848 DOI: 10.3389/fneur.2020.522583] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Accepted: 09/30/2020] [Indexed: 11/13/2022] Open
Abstract
Objective: To evaluate effectiveness and safety of Pipeline embolization device (PED) for large or giant verterbrobasilar aneurysms (LGVBAs), and to compare the therapeutic effects of PED with and without adjunctive coils. Methods: We retrospectively analyzed 21 cases of unruptured LGVBAs who were treated in our hospital with PED. These cases were divided into "PED group" and "PED with adjunctive coils group." We compared the aneurysm characteristics and treatment outcomes between the two groups. Results: The overall neurological complication rate was 28.6% (6/21) and the mortality rate was 4.8% (1/21). There were 12 patients in the PED group and nine in the PED with adjunctive coils group. There were no significant differences in age, smoking, hypertension, aneurysm size, aneurysm location, or operation time between the two groups. The complete aneurysm embolization rate and favorable outcome rate (modified Rankin Scale = 0,1) of the PED with adjunctive coils group was 78% (7/9) and 100% (9/9), respectively, which were both better compared with the PED group with 63.6% (7/11) and 83% (10/12), respectively. However, these differences were not statistically significant. Conclusion: The effectiveness and safety of PED for LGVBAs is acceptable. Treatment results did not differ between the PED and PED with adjunctive coils groups; therefore, whether coils should be used may depend the operator. Our results suggest that correct use of the coils does not increase complications. We suggest that PED with adjunctive coils should be used for some selected LGVBAs.
Collapse
|
33
|
Mulder HA, Stewart JB, Blue IP, Krakowiak RI, Patterson JL, Karin KN, Royals JM, DuPont AC, Forsythe KE, Poklis JL, Poklis A, Butler SN, Turner JBM, Peace MR. Characterization of E-cigarette coil temperature and toxic metal analysis by infrared temperature sensing and scanning electron microscopy - energy-dispersive X-ray. Inhal Toxicol 2020; 32:447-455. [PMID: 33140978 DOI: 10.1080/08958378.2020.1840678] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
INTRODUCTION Electronic cigarettes (e-cigarettes) have rapidly evolved since their introduction to the U.S. market. The rebuildable atomizer (RBA) offers user-driven modification to the heating element (coil) and wicking systems. Different coil materials can be chosen based on user needs and preferences. However, the heating element of an e-cigarette is believed to be one-source for toxic metal exposure. METHODS E-cigarette coils from Kanthal and nichrome wires were constructed in a contact and non-contact configuration and heated at four voltages. The maximum temperatures of the coils were measured by infrared temperature sensing when dry and when saturated with 100% vegetable glycerin or 100% propylene glycol. The metal composition of each coil was analyzed with Scanning Electron Microscopy-Energy-Dispersive X-Ray (SEM-EDX) when new, and subsequently after 1, 50, and 150 heat cycles when dry. RESULTS The coils reached temperatures above 1000 °C when dry, but were below 300 °C in both liquid-saturated mediums. Metal analysis showed a decrease of 9-19% chromium and 39-58% iron in Kanthal wire and a decrease of 12-14% iron and 39-43% nickel in nichrome wire after 150 heat cycles. Significant metal loss was observed after one heat cycle for both coil alloys and configurations. CONCLUSIONS The loss of metals from these heat cycles further suggests that the metals from the coils are potentially entering the aerosol of the e-cigarette, which can be inhaled by the user.
Collapse
|
34
|
Tsukahara S, Shimohira M, Nagai K, Ohta K, Sawada Y, Hashizume T, Goto T, Shibamoto Y. Use of 0.014-in. pushable bare platinum coils in super-selective embolization through the 1.6-Fr. microcatheter of the triaxial system. Acta Radiol Open 2020; 9:2058460120964066. [PMID: 33101706 PMCID: PMC7549165 DOI: 10.1177/2058460120964066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 09/12/2020] [Indexed: 11/16/2022] Open
Abstract
Background A triple-coaxial (triaxial) system, which consists of a small microcatheter, a large microcatheter, and a 4-Fr. catheter, has been reported to allow super-selective catheterization. A 1.6-Fr. microcatheter has recently become available as the small microcatheter for the triaxial system, in addition to 0.014-in. pushable bare platinum coils that may be introduced into the 1.6-Fr. microcatheter. Purpose The purpose of the present study was to evaluate the feasibility of 0.014-in. pushable bare platinum coils in embolization through the 1.6-Fr. microcatheter of the triaxial system. Material and Methods Between November 2015 and October 2019, 19 embolizations were performed on 18 patients, 9 males and 9 females with a median age of 77 years (range, 41-88 years), using 0.014-in. pushable bare platinum coils through the 1.6-Fr. microcatheter of the triaxial system. The technical success rate, clinical success rate, and complications associated with the procedure were assessed. Technical success was defined as the successful delivery and placement of 0.014-in. pushable bare platinum coils, and clinical success as the immediate postembolic complete cessation of blood flow confirmed by digital subtraction angiography. Results Eighty-four 0.014-in. pushable bare platinum coils were delivered and 19 arteries were successfully embolized. The median number of 0.014-in. pushable bare platinum coils was 4 (range, 1-12). The technical success rate was 100% (84/84) and the clinical success rate was also 100% (19/19). There were no complications associated with the procedures. Conclusion The use of 0.014-in. pushable bare platinum coils in super-selective embolization through the 1.6-Fr. microcatheter of the triaxial system appears to be feasible and safe.
Collapse
|
35
|
Li J, Wang T, Richard SA, Zhang C, Xie X, Wang C. Bilateral pediatric pial arteriovenous fistulas accompanying a giant arachnoid cyst with torticollis: A case report. Medicine (Baltimore) 2020; 99:e20991. [PMID: 32590813 PMCID: PMC7328906 DOI: 10.1097/md.0000000000020991] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 05/11/2020] [Accepted: 05/29/2020] [Indexed: 02/05/2023] Open
Abstract
RATIONALE Pial arteriovenous fistula (PAVF) occurs when intracranial arteries communicate directly with veins. PAVFs are very rare congenital vascular lesions that are commonly seen in infants and children. Arachnoid cysts are congenital cavitation often filled with cerebrospinal fluid. We present a very rare associated occurrence of bilateral pediatric PAVF and a giant arachnoid cyst presenting as torticollis in a child. So far, this is the first case. PATIENT CONCERNS A 6-year-old male child was referred to our facility from a local hospital due to severe torticollis. DIAGNOSES An enhanced computed tomography scan revealed 2 slightly high-density masses at the anterior pontine cistern, right circumferential cistern, as well as left posterior occipital region. The same computed tomography scan revealed a giant arachnoid cyst in the left occipital as well as the temporal region with a thin cerebral cortex adjacent to the cyst. INTERVENTIONS Digital subtraction angiography confirmed that the 2 high-flow lesions were PAVFs. The patient was treated with a combination of detachable coils and Onyx Liquid Embolic System (Onyx HD-500) (Covidien/ev3 Neurovascular) via the transarterial endovascular route while the giant arachnoid cyst was managed conservatively. OUTCOMES The torticollis resolved 2 days after the procedure. He is currently well with no neurologic deficit. LESSONS We advocate that in cases of PAVF with accompanying cyst, the cyst should be managed conservatively if it is not associated with intracranial hemorrhage or focal neurologic deficit.
Collapse
|
36
|
Massey ZB, Li Y, Holli J, Churchill V, Yang B, Henderson K, Ashley DL, Huang J, Popova L. Modifications to Electronic Nicotine Delivery Systems: Content Analysis of YouTube Videos. J Med Internet Res 2020; 22:e17104. [PMID: 32348288 PMCID: PMC7298628 DOI: 10.2196/17104] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 02/25/2020] [Accepted: 02/26/2020] [Indexed: 01/29/2023] Open
Abstract
BACKGROUND As user modification can alter the addictiveness and toxicity of electronic nicotine delivery systems (ENDS), more research is needed to understand the types, motivations, risks, and information sources that lead to these product alterations. YouTube has been identified as a major platform where ENDS users obtain and share information about ENDS products and modifications. However, a comprehensive study of ENDS modification videos on YouTube is lacking. OBJECTIVE This study aimed to analyze the content of YouTube videos depicting modifications of ENDS. METHODS YouTube was searched in March 2019 to identify videos depicting ENDS modifications. Search terms were derived from interviews with ENDS users and current literature. We used 28 search phrases that combined the words vape and vaping with modification-related key terms (eg, custom build, modification, and dripping). The final sample included 168 videos. RESULTS Videos were 1 to 108 min long (median 9.55). Presenters were largely male (117/168, 69.6%), white (94/168, 56.0%), and older than 25 years (94/168, 56.0%). Most videos gave how to instructions (148/168, 88.1%), but few offered warnings (30/168, 17.9%) or mentioned commercial alternatives to modifications they presented (16/168, 9.5%). The ENDS devices most often featured were drippers (63/168, 37.5%) and refillable tanks (37/168, 22.0%). The most often modified ENDS components were coils (82/168, 48.8%) and e-liquids (34/168, 20.2%), which included adding other substances, such as cannabis, to the e-liquids (6/168, 3.6%). Most videos portrayed ENDS modifications positively (106/168, 63.1% positive; 60/168, 35.7% neutral; and 2/168, 1.2% negative) and were either neutral or positive in their overall portrayal of ENDS devices (78/168, 46.4% positive; 89/168, 53.0% neutral; and 1/168, 0.6% negative). CONCLUSIONS This study identified several concerning trends in popular YouTube videos on ENDS modifications, including lack of warnings, the addition of marijuana derivatives to e-liquids, and the positive portrayal of ENDS devices and modifications. By identifying the types of modifications (coil and e-liquid being the most prevalent), this study sets an agenda for research on the effects of modifications.
Collapse
|
37
|
Silverberg D, Bar-Dayan A, Rimon U, Raskin D, Fefer P, Halak M. The Jailed Coiling Technique for the Treatment of Penetrating Ulcers and Saccular Aneurysms of the Aortic Arch. Vasc Endovascular Surg 2020; 54:423-429. [PMID: 32323631 DOI: 10.1177/1538574420921282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To evaluate the technical success and short-term outcome of patients with penetrating aortic ulcers (PAUs) and saccular aneurysms (SAs) of the aortic arch treated with the jailed coiling technique. METHODS A retrospective review of 9 patients (mean age 70 years, 9 males) treated for PAUs and SAs of the aortic arch between 2018 and 2019 at our institution. Treatment included thoracic endovascular aneurysm repair (TEVAR) with a short (1cm) proximal landing zone, followed by coiling of aneurysm through a jailed extraluminal catheter. RESULTS All 9 patients underwent TEVAR followed by jailed coiling of the lumen of the aneurysms. Debranching of supra-aortic vessels was performed in 4 patients in order to create a proximal landing zone of at least 10 mm. Technical success was achieved in all cases. Coils were placed accurately within the aneurysm lumen in all patients. No distal embolization occurred. One patient expired in the perioperative period from a cardiac event. No patient developed spinal cord ischemia or stroke in the perioperative period. Mean follow-up was 10 months (range 3-18). On follow-up imaging, complete thrombosis of the aneurysm lumen was seen in all patients. None experienced enlargement of ulcer dimensions and none required reintervention. CONCLUSION PAUs and SAs of the aortic arch with a very short landing zone can be treated successfully by jailed coiling of the aneurysm and TEVAR. The procedure is technically feasible and can be performed with minimal morbidity. Long-term durability of the repair needs to be determined.
Collapse
|
38
|
Pereira N, Lima AC, Correia V, Peřinka N, Lanceros-Mendez S, Martins P. Magnetic Proximity Sensor Based on Magnetoelectric Composites and Printed Coils. MATERIALS 2020; 13:ma13071729. [PMID: 32272728 PMCID: PMC7212752 DOI: 10.3390/ma13071729] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Accepted: 04/01/2020] [Indexed: 02/06/2023]
Abstract
Magnetic sensors are mandatory in a broad range of applications nowadays, being the increasing interest on such sensors mainly driven by the growing demand of materials required by Industry 4.0 and the Internet of Things concept. Optimized power consumption, reliability, flexibility, versatility, lightweight and low-temperature fabrication are some of the technological requirements in which the scientific community is focusing efforts. Aiming to positively respond to those challenges, this work reports magnetic proximity sensors based on magnetoelectric (ME) polyvinylidene fluoride (PVDF)/Metglas composites and an excitation-printed coil. The proposed magnetic proximity sensor shows a maximum resonant ME coefficient (α) of 50.2 Vcm−1 Oe−1, an AC linear response (R2 = 0.997) and a maximum voltage output of 362 mV, which suggests suitability for proximity-sensing applications in the areas of aerospace, automotive, positioning, machine safety, recreation and advertising panels, among others.
Collapse
|
39
|
Li Y, Fairman RT, Churchill V, Ashley DL, Popova L. Users' Modifications to Electronic Nicotine Delivery Systems (ENDS): Interviews with ENDS Enthusiasts. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17030918. [PMID: 32024230 PMCID: PMC7037434 DOI: 10.3390/ijerph17030918] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 01/30/2020] [Accepted: 01/31/2020] [Indexed: 11/16/2022]
Abstract
Users' modifications to electronic nicotine delivery systems (ENDS) products could increase initiation, inhibit cessation, or change the toxicity of the product. This study aims to begin to identify consumers' common ENDS modification behaviors. We conducted audio-recorded, in-depth one-on-one interviews with 13 adult ENDS users in the metropolitan Atlanta area, who self-reported extensive modification experience. Modifications to coils, batteries, and e-liquids were commonly mentioned. Participants indicated that users modified devices to produce large clouds, change levels of nicotine delivery, alter tastes of e-liquids, and experience different throat hits. Because manufacturers have changed product characteristics to be in line with consumer preferences, interviewees indicated that fewer users currently engage in modifications to coils and batteries compared to the more widespread practice a few years ago. Hobbyists continue to perform modifications and many users continue to misuse or abuse e-liquids, despite the view that fewer users currently alter their ENDS than in the past. The Food and Drug Administration (FDA) regulatory actions that limit certain product characteristics may unintentionally increase the likelihood that users will once again make more extensive modifications to their products, and this should be considered as part of the FDA's regulatory decision-making process.
Collapse
|
40
|
Gorsi U, Bansal A, Jugpal TS, Chaluvashetty SB, Sandhu MS. Endovascular Management of Massive Hemoptysis Secondary to Systemic Collaterals in Previously Treated Pulmonary Arteriovenous Malformation. Vasc Endovascular Surg 2019; 53:674-678. [PMID: 31431148 DOI: 10.1177/1538574419870433] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Pulmonary arteriovenous malformations (PAVMs) are abnormal connections between pulmonary artery and vein through a thin-walled aneurysmal sac, leading to a right-to-left shunt. These are commonly associated with hereditary hemorrhagic telangiectasia, and treatment guidelines have been set on how to approach their management. Incorrect proximal placement of an embolization device can lead to delayed recruitment of systemic collaterals leading to presentation with hemoptysis. We are presenting a case of a 17-year-old male with treated PAVMs and with fresh hemoptysis. In this case report, we attempt to explain the management of such a complication and follow the principles of arteriovenous malformation embolization on the left side.
Collapse
|
41
|
Setlur Nagesh SV, Vakharia K, Waqas M, Fennell VS, Atwal GS, Shallwani H, Bednarek DR, Davies JM, Snyder KV, Mokin M, Rudin S, Levy EI, Siddiqui AH. High-Definition Zoom Mode: A High Resolution X-ray Microscope for Neurointerventional Treatment Procedures. J Neuroimaging 2019; 29:565-572. [PMID: 31339613 DOI: 10.1111/jon.12652] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Accepted: 06/20/2019] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND AND PURPOSE Visualization of structural details of treatment devices during neurointerventional procedures can be challenging. A new true two-resolution imaging X-ray detector system features a 194 µm pixel conventional flat-panel detector (FPD) mode and a 76 µm pixel high-resolution high-definition (Hi-Def) zoom mode in one detector panel. The Hi-Def zoom mode was developed for use in interventional procedures requiring superior image quality over a small field of view (FOV). We report successful use of this imaging system during intracranial aneurysm treatment in 1 patient with a Pipeline-embolization device and 1 patient with a low-profile visualized intramural support (LVIS Blue) device plus adjunctive coiling. METHODS A guide catheter was advanced from the femoral artery insertion site to the proximity of each lesion using standard FPD mode. Under magnified small FOV Hi-Def imaging mode, an intermediate catheter and microcatheters were guided to the treatment site, and the PED and LVIS Blue plus coils were deployed. Radiation doses were tracked intraprocedurally. RESULTS Critical details, including structural changes in the PED and LVIS Blue and position and movement of the microcatheter tip within the coil mass, were more readily apparent in Hi-Def mode. Skin-dose mapping indicated that Hi-Def mode limited radiation exposure to the smaller FOV of the treatment area. CONCLUSIONS Visualization of device structures was much improved in the high-resolution Hi-Def mode, leading to easier, more controlled deployment of stents and coils than conventional FPD mode.
Collapse
|
42
|
Anneberg TJ, Segraves KA. Intraspecific polyploidy correlates with colonization by arbuscular mycorrhizal fungi in Heuchera cylindrica. AMERICAN JOURNAL OF BOTANY 2019; 106:894-900. [PMID: 31162645 DOI: 10.1002/ajb2.1294] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Accepted: 03/26/2019] [Indexed: 06/09/2023]
Abstract
PREMISE Polyploidy is known to cause physiological changes in plants which, in turn, can affect species interactions. One major physiological change predicted in polyploid plants is a heightened demand for growth-limiting nutrients. Consequently, we expect polyploidy to cause an increased reliance on the belowground mutualists that supply these growth-limiting nutrients. An important first step in investigating how polyploidy affects nutritional mutualisms in plants, then, is to characterize differences in the rate at which diploids and polyploids interact with belowground mutualists. METHODS We used Heuchera cylindrica (Saxifragaceae) to test how polyploidy influences interactions with arbuscular mycorrhizal fungi (AMF). Here we first confirmed the presence of AMF in H. cylindrica, and then we used field-collected specimens to quantify and compare the presence of AMF structures while controlling for site-specific variation. RESULTS Tetraploids had higher colonization rates as measured by total, hyphal, and nutritional-exchange structures; however, we found that diploids and tetraploids did not differ in vesicle colonization rates. CONCLUSIONS The results suggest that polyploidy may alter belowground nutritional mutualisms with plants. Because colonization by nutritional-exchange structures was higher in polyploids but vesicle colonization was not, polyploids might form stronger associations with their AMF partners. Controlled experiments are necessary to test whether this pattern is driven by the direct effect of polyploidy on AMF colonization.
Collapse
|
43
|
Edelmann JC, Mair D, Ussmueller T. A novel measurement strategy to evaluate the human head as a transition medium for inductive ear-to-ear communication. BIOMED ENG-BIOMED TE 2019; 64:233-241. [PMID: 29894298 DOI: 10.1515/bmt-2017-0157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Accepted: 05/14/2018] [Indexed: 11/15/2022]
Abstract
This manuscript introduces a novel concept for measuring coil coupling for extremely loose-coupled coils (coupling factors k<10-6; mutual inductance values M<10-10 H). Such a coupling is found everywhere where the ratio of solenoid diameter to coil spacing is >50. Measuring these quantities with a low-power technology requires a sophisticated setup that goes beyond the sensitivity of state-of-the art approaches. The methodology is validated using laboratory measurements with three sets of solenoids (two ferrite-cored, one air-cored) and numerical simulations with COMSOL Multiphysics 5.2a, Stockholm, Sweden. The concept is then employed to investigate the channel characteristics for inductive through-the-head communication within the 3.155-3.195 MHz band. This selected part of the spectrum is in accordance with International Telecommunication Union Radio Regulation 5.116 for low-power wireless hearing aids. By applying a phantom solution, we demonstrate that human tissue layers are transparent for magnetic fields within these frequencies. However, the influence from the relative coil arrangement is evaluated in detail as it restricts the communication range significantly. The coupling results for off-the-shelf Sonion, Roskilde, Denmark, RF 02 AA 10 solenoids considering both lateral and axial displacements might be of special interest for a number of near-field applications.
Collapse
|
44
|
Wang X, Yu S, Chen X, Duan L. Endoscopic ultrasound-guided injection of coils and cyanoacrylate glue for the treatment of gastric fundal varices with abnormal shunts: a series of case reports. J Int Med Res 2019; 47:1802-1809. [PMID: 30819006 PMCID: PMC6460599 DOI: 10.1177/0300060519830207] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Gastric varices are found in approximately 20% of patients with portal hypertension. Endoscopic procedures involving the injection of cyanoacrylate (CYA) have proven to be the therapies of choice for primary treatment of gastric varices and have resulted in higher hemostasis rates and lower recurrent bleeding rates compared with band ligation and sclerotherapy. Nevertheless, serious adverse events associated with CYA injection, including glue embolization, have been reported in numerous articles and have occasionally led to fatal adverse events. Gastric fundal varices with abnormal shunts are higher-risk than those without abnormal shunts, and their treatment is more challenging. Endoscopic ultrasound (EUS)-guided puncture is an important technique in the field of digestive endoscopy. EUS has advantages that include improved therapeutic targeting, enhanced variceal detection, the ability to confirm varix obliteration with Doppler examination, and the ability to perform accurate observations of gastric varices that are not affected by blood in the stomach. The coils currently used for intravascular embolization can be precisely delivered into a varix through fine-needle puncture under EUS guidance, and this technique has provided a new approach for varix obliteration. We herein describe two patients with severe gastric fundal varices who were treated with EUS-guided coil injection and CYA embolization.
Collapse
|
45
|
Superior ophthalmic vein and ophthalmic artery in immediate evaluation after endovascular treatment of carotid-cavernous fistulas. Pol J Radiol 2019; 84:e32-e40. [PMID: 31019592 PMCID: PMC6479058 DOI: 10.5114/pjr.2019.82807] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2018] [Accepted: 12/03/2018] [Indexed: 11/17/2022] Open
Abstract
Purpose To validate superior ophthalmic vein (SOV) and ophthalmic artery (OA) usefulness in immediate evaluation of new endovascular approaches to treat carotid-cavernous fistulas (CCFs). Material and methods A retrospective review of 597 intracerebral malformation embolisations yielded 40 embolisations of CCF in the treatment of 18 patients. Two interventional radiologists performed detailed radiological angiographic assessments. Results Mean age at initial admission was 58.9 years (SD 18.5 years, range 24-85 years). Patients presented with: chemosis (50%), ocular bruit (50%), exophthalmos (61%), diminished visual acuity (77.8%), headache (16.7%), and intracerebral haemorrhage (5.55%), and 5.55% were asymptomatic. Unilateral fistulas (10-55.5%) showed more diversified venous drainage pattern than bilateral ones (8-44.4%). There were statistically significant differences in post-traumatic and spontaneous CCF regarding age (p = 0.036), type of fistula (p = 0.0008), and presence of pseudoaneurysm (p = 0.036). 77.8% of patients had increased ipsilateral SOV diameter. SOV enlargement was not associated with type of fistula, history of trauma, or degree of exophthalmos. Ipsilateral ophthalmic artery was visible in all patients on both pre- and postprocedural angiography on lateral projection. Pre- and post-procedural SOV diameter was significantly different. Internal carotid artery patency was 100%, while the overall final angiographic or clinical success was 85.7%. We had three cases of peri-procedural complications. Conclusions We reported changeable dynamics of SOV and OA after endovascular treatment of CCFs and proved the feasibility of coils and Onyx-18 in the treatment thereof.
Collapse
|
46
|
Poggi C, Mantovani S, Pecoraro Y, Carillo C, Bassi M, D'Andrilli A, Anile M, Rendina EA, Venuta F, Diso D. Bronchoscopic treatment of emphysema: an update. J Thorac Dis 2018; 10:6274-6284. [PMID: 30622803 DOI: 10.21037/jtd.2018.10.43] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Chronic obstructive pulmonary disease (COPD) is the major causes of disability and mortality. The efficacy of maximal medical treatment, although effective at the early stages of the disease, becomes limited when extensive alveolar destruction is the main cause of respiratory failure. At this stage of the disease more aggressive options, when feasible, should be considered. Lung transplantation and lung volume reduction surgery (LVRS) are currently available for a selected group of patients. Endoscopic alternatives to LVRS have progressively gained acceptance and are currently employed in patients with COPD. They promote lung deflation searching the same outcome as LVRS in terms of respiratory mechanics, ameliorating the distressing symptom of chronic dyspnea by decreasing the physiological dead space.
Collapse
|
47
|
Fellrath JM, Scherer T, Franzen DP, Lovis A, von Garnier C, Plojoux J, Soccal PM. Endobronchial coil therapy in severe emphysema: 6-month outcomes from a Swiss National Registry. J Thorac Dis 2018; 10:S2711-S2718. [PMID: 30210823 PMCID: PMC6129812 DOI: 10.21037/jtd.2018.04.53] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Accepted: 04/09/2018] [Indexed: 11/06/2022]
Abstract
BACKGROUND Endobronchial coils have been demonstrated in three randomized, controlled trials to improve quality of life, exercise tolerance, and lung function in patients with severe emphysema. This therapy is CE-marked and commercially available in Switzerland. Coil treated patients are followed in a post-market Swiss registry to collect safety and effectiveness data in routine clinical practice. METHODS The Swiss coil registry was initiated in October 2013. At the end of November 2016, an interim analysis of all 64 patients treated in five centers was performed to evaluate safety and effectiveness at six months post treatment. RESULTS patients had completed bilateral treatment with 6-month follow up at the time of data analysis. Patients had very severe, symptomatic emphysema and hyperinflation [38% male, mean age 66 years, BMI 24, FEV1 30% pred., residual volume (RV) 247% pred., 6-minute walking distance (6-MWD) 272 m, St. George Respiratory Questionnaire (SGRQ) 57 points]. Up to 6 months following treatment, seven serious adverse events (SAE) were reported in 6/29 patients. No device removals were necessary. At 6 months, responder rates [% achieving the minimal clinically important difference (MCID)] were as follows: RV (-0.35 L) 76%; FEV1 (+10%) 57%; SGRQ (-4 points) 87%; 6MWD (+26 m) 60%. CONCLUSIONS Endobronchial coil therapy performed in expert centers in Switzerland yields high 6-month responder rates across all relevant outcome.
Collapse
|
48
|
Welling JBA, Slebos DJ. Lung volume reduction with endobronchial coils for patients with emphysema. J Thorac Dis 2018; 10:S2797-S2805. [PMID: 30210833 DOI: 10.21037/jtd.2017.12.95] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The lung volume reduction coil treatment is a minimally invasive bronchoscopic treatment option for emphysema patients who suffer from severe hyperinflation. The treatment is aimed at a large group of patients where lung volume reduction surgery and bronchoscopic lung volume reduction using endobronchial valves are no option, or alternatively, can be offered as a bridge to lung transplantation. The nitinol coil exhibits a shape memory effect and is biologically inert. The lung volume reduction coil procedure is performed in two separate treatment sessions, targeting one lobe per session, with the contralateral lobe being treated 4 to 8 weeks after the first session. In one treatment session, around 10 to 14 coils, thereby treating an entire lobe, are being placed. Selecting optimally treated, symptomatic chronic obstructive pulmonary disease (COPD) patients with emphysema and severe hyperinflation, while avoiding significant airway disease such as asthma, chronic bronchitis and bronchiectasis, is key to achieve treatment success. Three randomized clinical trials investigating lung volume reduction coil treatment have been published until now, reporting the results of 452 treated patients up to 12 months after coil treatment. Lung volume reduction coil treatment results in significant improvement of pulmonary function outcomes and quality of life in patients with severe hyperinflation. The most common complications of lung volume reduction coil treatment are: COPD exacerbations, pneumonia, Coil Associated Opacity and an increased risk of pneumothorax. The purpose of this article is to describe the coil technique and review the available literature regarding effect, safety and future perspectives of lung volume reduction with coils for emphysema patients.
Collapse
|
49
|
Kawsara A, Núñez Gil IJ, Alqahtani F, Moreland J, Rihal CS, Alkhouli M. Management of Coronary Artery Aneurysms. JACC Cardiovasc Interv 2018; 11:1211-1223. [DOI: 10.1016/j.jcin.2018.02.041] [Citation(s) in RCA: 98] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Revised: 01/07/2018] [Accepted: 02/20/2018] [Indexed: 01/11/2023]
|
50
|
Bakker A, Siegel JA, Mendell MJ, Peccia J. Building and environmental factors that influence bacterial and fungal loading on air conditioning cooling coils. INDOOR AIR 2018; 28:689-696. [PMID: 29846963 DOI: 10.1111/ina.12474] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Accepted: 05/08/2018] [Indexed: 06/08/2023]
Abstract
We investigated bacterial and fungal concentrations on cooling coils of commercial AC units and quantified associations between microbial loads and AC unit or building operational parameters. A field campaign was conducted to sample 25 AC units in the humid, subtropical climate of Southern CT, USA and 15 AC units in the hot-summer Mediterranean climate of Sacramento, CA, USA. Median concentrations (with interquartile range) of bacteria and fungi on the cooling coils were 1.2 × 107 (5.1 × 106 -3.9 × 107 ) cells/m2 and 7.6 × 105 (5.6 × 104 -4.4 × 106 ) spore equivalents (SE)/m2 , respectively. Concentrations varied among units with median unit concentrations ranging three orders of magnitude for bacteria and seven orders of magnitude for fungi. Controlled comparisons and multivariable regressions indicate that dominant factors associated with AC coil loading include the nominal efficiency of upstream filters (P = .008 for bacteria and P < .001 for fungi) and coil moisture, which was reflected in fungal loading differences between top and bottom halves of the AC coils in Southern CT (P = .05) and the dew points of the two climates considered (P = .04). Environmental and building characteristics explained 42% (P < .001) of bacterial concentration variability and 66% (P < .001) of fungal concentration variability among samples.
Collapse
|