101
|
Malbouisson LM, Busch CJ, Puybasset L, Lu Q, Cluzel P, Rouby JJ. Role of the heart in the loss of aeration characterizing lower lobes in acute respiratory distress syndrome. CT Scan ARDS Study Group. Am J Respir Crit Care Med 2000; 161:2005-12. [PMID: 10852781 DOI: 10.1164/ajrccm.161.6.9907067] [Citation(s) in RCA: 111] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
In the acute respiratory distress syndrome (ARDS), lower lobes appear essentially non-aerated in contrast to upper lobes whose aeration can be preserved in some patients. The aim of this study was to assess the mechanical compression exerted by the heart on lower lobes in patients with ARDS. Fourteen healthy volunteers and 38 patients with ARDS free of left ventricular failure were studied. Cardiorespiratory parameters were recorded and the cardiac dimensions, the pressure exerted by the heart on subjacent lower lobes, and the gas tissue ratio of lower lobes in the supine position were measured using computer tomography and Lungview, a specifically designed software. In patients with ARDS, the heart was larger and heavier than in healthy volunteers. The enlargement of the heart was mainly related to a left cardiac protrusion and the pressure exerted by the left heart on the lower lobes was higher in patients with ARDS than in healthy volunteers (8 +/- 3 g. cm(-)(2) versus 6 +/- 1 g. cm(-)(2), p < 0.01). As a consequence, the faction of gas represented 62% of the left lower lobes in healthy volunteers and 12% only in patients with ARDS. The present study demonstrates that apart from the already known anteroposterior and cephalocaudal gradients of pressure depending on the lung weight and abdominal pressure, the heart plays an important role in the dramatic loss of aeration characterizing lower lobes of patients with ARDS lying in the supine position.
Collapse
Affiliation(s)
- L M Malbouisson
- Réanimation Chirurgicale Pierre Viars, Department of Anesthesiology, Hôpital de la Pitié-Salpêtrière, University of Paris VI, Paris, France
| | | | | | | | | | | |
Collapse
|
102
|
Lu Q, Rouby JJ. Measurement of pressure-volume curves in patients on mechanical ventilation. Methods and significance. Minerva Anestesiol 2000; 66:367-75. [PMID: 10965718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
Abstract
In critically ill patients measurements of pressure volume curves has been suggested as a method for assessing the severity of lung injury and for monitoring the evolution of the lung disease; it can also guide the ventilatory adjustments to optimize the mechanical ventilation. The static pressure-volume curves are impaired in acute respiratory distress syndrome (ARDS). The evaluation of the lower and upper inflection point on the pressure-volumes curves at the bedside of patients with acute respiratory failure means to apply a "protective ventilatory strategy". The combined application of positive end expiratory pressure (PEEP) to the level of alveolar recruitment and low tidal volume (< 6 ml/kg) ameliorates the lung function and decrease mortality in ARDS patients. Routine monitoring with continuous technique is easy and develops good therapeutic practice.
Collapse
Affiliation(s)
- Q Lu
- Surgical Intensive Care Unit Pierre Viars, Department of Anesthesiology, La Pitié-Salpêtrière Hospital, University of Paris VI, France
| | | |
Collapse
|
103
|
|
104
|
Lu Q, Rouby JJ. Measurement of pressure-volume curves in patients on mechanical ventilation: methods and significance. Crit Care 2000; 4:91-100. [PMID: 11094498 PMCID: PMC137332 DOI: 10.1186/cc662] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/1999] [Revised: 03/03/2000] [Accepted: 03/03/2000] [Indexed: 11/14/2022] Open
Abstract
Physiological background concerning mechanics of the respiratory system, techniques of measurement and clinical implications of pressure-volume curve measurement in mechanically ventilated patients are discussed in the present review. The significance of lower and upper inflection points, the assessment of positive end-expiratory pressure (PEEP)-induced alveolar recruitment and overdistension and rationale for optimizing ventilatory settings in patients with acute lung injury are presented. Evidence suggests that the continuous flow method is a simple and reliable technique for measuring pressure-volume curves at the bedside. In patients with acute respiratory failure, determination of lower and upper inflection points and measurement of respiratory compliance should become a part of the routine assessment of lung injury severity, allowing a bedside monitoring of the evolution of the lung disease and an optimization of mechanical ventilation.
Collapse
Affiliation(s)
- Q Lu
- University of Paris VI, Paris, France.
| | | |
Collapse
|
105
|
|
106
|
Richecoeur J, Lu Q, Vieira SR, Puybasset L, Kalfon P, Coriat P, Rouby JJ. Expiratory washout versus optimization of mechanical ventilation during permissive hypercapnia in patients with severe acute respiratory distress syndrome. Am J Respir Crit Care Med 1999; 160:77-85. [PMID: 10390383 DOI: 10.1164/ajrccm.160.1.9809006] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
The aim of this study was to compare three ventilatory techniques for reducing PaCO2 in patients with severe acute respiratory distress syndrome treated with permissive hypercapnia: (1) expiratory washout alone at a flow of 15 L/min, (2) optimized mechanical ventilation defined as an increase in the respiratory frequency to the maximal rate possible without development of intrinsic positive end- expiratory pressure (PEEP) combined with a reduction of the instrumental dead space, and (3) the combination of both methods. Tidal volume was set according to the pressure-volume curve in order to obtain an inspiratory plateau airway pressure equal to the upper inflection point minus 2 cm H2O after setting the PEEP at 2 cm H2O above the lower inflection point and was kept constant throughout the study. The three modalities were compared at the same inspiratory plateau airway pressure through an adjustment of the extrinsic PEEP. During conventional mechanical ventilation using a respiratory frequency of 18 breaths/min, respiratory acidosis (PaCO2 = 84 +/- 24 mm Hg and pH = 7.21 +/- 0.12) was observed. Expiratory washout and optimized mechanical ventilation (respiratory frequency of 30 +/- 4 breaths/min) had similar effects on CO2 elimination (DeltaPaCO2 = -28 +/- 11% versus -27 +/- 12%). A further decrease in PaCO2 was observed when both methods were combined (DeltaPaCO2 = -46 +/- 7%). Extrinsic PEEP had to be reduced by 5.3 +/- 2.1 cm H2O during expiratory washout and by 7.3 +/- 1.3 cm H2O during the combination of the two modes, whereas it remained unchanged during optimized mechanical ventilation alone. In conclusion, increasing respiratory rate and reducing instrumental dead space during conventional mechanical ventilation is as efficient as expiratory washout to reduce PaCO2 in patients with severe ARDS and permissive hypercapnia. When used in combination, both techniques have additive effects and result in PaCO2 levels close to normal values.
Collapse
Affiliation(s)
- J Richecoeur
- Réanimation Chirurgicale Pierre Viars, Department of Anesthesiology, La Pitié-Salpêtrière Hospital, University of Paris VI, France
| | | | | | | | | | | | | |
Collapse
|
107
|
Vieira SR, Puybasset L, Lu Q, Richecoeur J, Cluzel P, Coriat P, Rouby JJ. A scanographic assessment of pulmonary morphology in acute lung injury. Significance of the lower inflection point detected on the lung pressure-volume curve. Am J Respir Crit Care Med 1999; 159:1612-23. [PMID: 10228135 DOI: 10.1164/ajrccm.159.5.9805112] [Citation(s) in RCA: 119] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
The goal of this study was to assess lung morphology in patients with acute lung injury according to the presence or the absence of a lower inflection point (LIP) on the lung pressure-volume (P-V) curve and to compare the effects of positive end-expiratory pressure (PEEP). Eight patients with and six without an LIP underwent a spiral thoracic CT scan performed at zero end-expiratory pressure (ZEEP) and at two levels of PEEP: PEEP1 = LIP + 2 cm H2O and PEEP2 = LIP + 7 cm H2O, or PEEP1 = 10 cm H2O and PEEP2 = 15 cm H2O in the absence of an LIP. The volumes of air and tissue within the lungs were measured from the gas-tissue ratio and the volumes of overdistended and normally, poorly, and nonaerated lung areas were determined by the analysis of the frequency histogram distribution. In the ZEEP condition, although total lung volume, volume of gas, and volume of tissue were similar in both groups, the percentage of normally aerated lung was lower (24 +/- 22% versus 55 +/- 12%, p < 0.05) and the percentage of poorly aerated lung was greater (40 +/- 12% versus 23 +/- 8%, p < 0.05) in patients with an LIP than in patients without an LIP. Lung density histograms of patients with an LIP showed a unimodal distribution with a peak at 7 Hounsfield units (HU). Lung density histograms of patients without an LIP had a bimodal distribution, with a first peak at -727 HU and a second peak at 27 HU. Total respiratory system and lung compliances were lower in patients with an LIP whereas all other cardiorespiratory parameters were similar in the two groups. In both groups, PEEP induced an alveolar recruitment that was associated with lung overdistension only in patients without an LIP. The amount of lung overdistension was related to the volume of lung parenchyma, characterized by a CT number less than -800 HU before PEEP implementation (y = 0.52x + 4, R = 0.87, and p < 0.0001). This study shows that the presence or the absence of an LIP on the lung P-V curve is associated with differences in lung morphology. In patients without an LIP on the lung P-V curve, normally aerated lung areas coexist with nonaerated lung areas and increasing levels of PEEP result in lung overdistension rather than in additional alveolar recruitment. In patients with an LIP, air and tissue are more homogeneously distributed within the lungs and increasing levels of PEEP result in additional alveolar recruitment without lung overdistention.
Collapse
Affiliation(s)
- S R Vieira
- Surgical Intensive Care Unit, Department of Anesthesiology, La Pitié-Salpêtrière Hospital, University of Paris VI, Paris, France
| | | | | | | | | | | | | |
Collapse
|
108
|
Lu Q, Vieira SR, Richecoeur J, Puybasset L, Kalfon P, Coriat P, Rouby JJ. A simple automated method for measuring pressure-volume curves during mechanical ventilation. Am J Respir Crit Care Med 1999; 159:275-82. [PMID: 9872850 DOI: 10.1164/ajrccm.159.1.9802082] [Citation(s) in RCA: 87] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Measurement of respiratory compliance is advocated for assessing the severity of acute respiratory failure (ARF). Recently, the administration of an automated constant flow of 15 L/min was proposed as a method easier to implement at the bedside than supersyringe or inspiratory occlusions methods. However, pressure-volume (P-V) curves were shifted to the right because of the resistive properties of the respiratory system. The aim of this study was to compare the P-V curves obtained using two constant flows-3 and 9 L/min-during volume-controlled mechanical ventilation with those obtained with the supersyringe and the inspiratory occlusions methods. Fourteen paralyzed patients with ARF were studied. The supersyringe and the inspiratory occlusions methods were performed according to usual recommendations. The new automated method was performed during volume-controlled mechanical ventilation by setting the inspiratory:expiratory ratio at 80%, the respiratory frequency at 5 breaths/min, and the tidal volume at 500 or 1,500 ml. These peculiar ventilatory settings were equivalent to administering a constant flow of 3 or 9 L/min during a 9.6-s inspiration. Esophageal and airway pressures were recorded. P-V curves obtained by the 3-L/min constant-flow method were identical to those obtained by the reference methods, whereas the P-V curve obtained by the 9-L/min constant flow was slightly shifted to the right. The slopes of the P-V curves and the lower inflection points were not different between all methods, indicating that the resistive component induced by administering a constant flow equal to or less than 9 L/min is not of clinical relevance. Because the 3-L/min constant-flow method is not artifacted by the resistive properties of the respiratory system and does not require any other equipment than a ventilator, it is an easy-to-implement, inexpensive, safe, and reliable method for measuring the thoracopulmonary P-V curve at the bedside.
Collapse
Affiliation(s)
- Q Lu
- Unité de Réanimation Chirurgicale, Department of Anesthesiology, La Pitié-Salpêtrière Hospital, University of Paris VI, France
| | | | | | | | | | | | | |
Collapse
|
109
|
Gallart L, Lu Q, Puybasset L, Umamaheswara Rao GS, Coriat P, Rouby JJ. Intravenous almitrine combined with inhaled nitric oxide for acute respiratory distress syndrome. The NO Almitrine Study Group. Am J Respir Crit Care Med 1998; 158:1770-7. [PMID: 9847266 DOI: 10.1164/ajrccm.158.6.9804066] [Citation(s) in RCA: 72] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Inhaled nitric oxide (iNO), a selective pulmonary vasodilator and intravenously administered almitrine, a selective pulmonary vasoconstrictor, have been shown to increase PaO2 in patients with acute respiratory distress syndrome (ARDS). This prospective study was undertaken to assess the cardiopulmonary effects of combining both drugs. In 48 consecutive patients with early ARDS, cardiorespiratory parameters were measured at control, after iNO 5 ppm, after almitrine 4 micrograms. kg-1. min-1, and after the combination of both drugs. In 30 patients, dose response to 2, 4, and 16 micrograms. kg-1. min-1 of almitrine with and without NO was determined. Almitrine and lactate plasma concentrations were measured in 17 patients. Using pure O2, PaO2 increased by 75 +/- 8 mm Hg after iNO, by 101 +/- 12 mm Hg after almitrine 4 micrograms. kg-1. min-1, and by 175 +/- 18 mm Hg after almitrine combined with iNO (p < 0.001). In 63% of the patients, PaO2 increased by more than 100% with the combination of both drugs. Mean pulmonary artery pressure (Ppa) increased by 1.4 +/- 0.2 mm Hg with almitrine 4 micrograms/kg/ min (p < 0.001) and decreased by 3.4 +/- 0.4 mm Hg with iNO and by 1.5 +/- 0.3 mm Hg with the combination (p < 0.001). The maximum increase in PaO2 was obtained at almitrine concentrations <= 4 micrograms. kg-1. min-1, whereas almitrine increased Ppa dose-dependently. Almitrine plasma concentrations also increased dose-dependently and returned to values close to zero after 12 h. In many patients with early ARDS, the combination of iNO 5 ppm and almitrine 4 micrograms. kg-1. min-1 dramatically increases PaO2 without apparent deleterious effect allowing a rapid reduction in inspired fraction of O2. The long-term consequences of this immediate beneficial effect remain to be determined.
Collapse
Affiliation(s)
- L Gallart
- Unité de Réanimation Chirurgicale (Department of Anesthesiology), Hôpital de la Pitié-Salpétrière, University of Paris VI, France
| | | | | | | | | | | |
Collapse
|
110
|
Puybasset L, Cluzel P, Chao N, Slutsky AS, Coriat P, Rouby JJ. A computed tomography scan assessment of regional lung volume in acute lung injury. The CT Scan ARDS Study Group. Am J Respir Crit Care Med 1998; 158:1644-55. [PMID: 9817720 DOI: 10.1164/ajrccm.158.5.9802003] [Citation(s) in RCA: 192] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
The lobar and cephalocaudal distribution of aerated and nonaerated lung and of PEEP-induced alveolar recruitment is unknown in acute lung injury (ALI). Dimensions of the lungs and volumes of aerated and nonaerated parts of each pulmonary lobe were measured using a computerized tomographic quantitative analysis and compared between 21 patients with ALI and 10 healthy volunteers. Distribution of PEEP-induced alveolar recruitment along the anteroposterior and cephalocaudal axis and influence of the resting volume of nonaerated lower lobes were also assessed. Anteroposterior and transverse dimensions of the lungs of the patients were similar to those of healthy volunteers, whereas cephalocaudal dimensions were reduced by more than 15%. Total lung volume (aerated plus nonaerated lung) was reduced by 27%. Volumes of upper and lower lobes were 99 and 48% of normal values. In addition to an anteroposterior gradient in the distribution of aerated and nonaerated areas, a cephalocaudal gradient was also observed. Nonaerated areas were predominantly found in juxtadiaphragmatic regions. PEEP-induced alveolar recruitment was more pronounced in nondependent than in dependent regions and in cephalad than in caudal regions. A significant correlation between resting volume of nonaerated lower lobes and regional PEEP-induced alveolar recruitment was observed. In ALI, loss of lung volume involves predominantly lower lobes. The thorax shortens along its cephalocaudal axis. PEEP-induced alveolar recruitment predominates in nondependent and cephalad lung regions and is inversely correlated with the resting volume of nonaerated lung.
Collapse
Affiliation(s)
- L Puybasset
- Unité de Réanimation Chirurgicale, Department of Anesthesiology and Department of Radiology (Thoracic Division), La Pitié-Salpêtrière Hospital, University of Paris VI, Paris, France
| | | | | | | | | | | |
Collapse
|
111
|
Vieira SR, Puybasset L, Richecoeur J, Lu Q, Cluzel P, Gusman PB, Coriat P, Rouby JJ. A lung computed tomographic assessment of positive end-expiratory pressure-induced lung overdistension. Am J Respir Crit Care Med 1998; 158:1571-7. [PMID: 9817710 DOI: 10.1164/ajrccm.158.5.9802101] [Citation(s) in RCA: 164] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
The aim of this study was to assess positive end-expiratory pressure (PEEP)-induced lung overdistension and alveolar recruitment in six patients with acute lung injury (ALI) using a computed tomographic (CT) scan method. Lung overdistension was first determined in six healthy volunteers in whom CT sections were obtained at FRC and at TLC with a positive airway pressure of 30 cm H2O. In patients, lung volumes were quantified by the analysis of the frequency distribution of CT numbers on the entire lung at zero end-expiratory pressure (ZEEP) and PEEP. In healthy volunteers at FRC, the distribution of the density histograms was monophasic with a peak at -791 +/- 12 Hounsfield units (HU). The lowest CT number observed was -912 HU. At TLC, lung volume increased by 79 +/- 35% and the peak CT number decreased to -886 +/- 26 HU. More than 70% of the increase in lung volume was located below -900 HU, suggesting that this value can be considered as the threshold separating normal aeration from overdistension. In patients with ALI, at ZEEP the distribution of density histograms was either monophasic (n = 3) or biphasic (n = 3). The mean CT number was -319 +/- 34 HU. At PEEP 13 +/- 3 cm H2O, lung volume increased by 47 +/- 19% whereas mean CT number decreased to -538 +/- 171 HU. PEEP induced a mean alveolar recruitment of 320 +/- 160 ml and a mean lung overdistension of 238 +/- 320 ml. In conclusion, overdistended lung parenchyma of healthy volunteers is characterized by a CT number below -900 HU. This threshold can be used in patients with ALI for differentiating PEEP-induced alveolar recruitment from lung overdistension.
Collapse
Affiliation(s)
- S R Vieira
- Unité de Réanimation Chirurgicale, Department of Anesthesiology and Department of Radiology (Thoracic Division), La Pitié-Salpêtrière Hospital, University of Paris VI, Paris, France
| | | | | | | | | | | | | | | |
Collapse
|
112
|
Puybasset L, Rouby JJ. Pulmonary uptake and modes of administration of inhaled nitric oxide in mechanically-ventilated patients. Crit Care 1998; 2:9-17. [PMID: 11094471 PMCID: PMC137224 DOI: 10.1186/cc118] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/1998] [Indexed: 11/10/2022] Open
Affiliation(s)
- Louis Puybasset
- Surgical Intensive Care Unit, Department of Anesthesiology, La Pitié-Salpêtrière Hospital, 47-89, Boulevard de I'Hôpital, 75013 Paris, France
| | - Jean-Jacques Rouby
- Surgical Intensive Care Unit, Department of Anesthesiology, La Pitié-Salpêtrière Hospital, 47-89, Boulevard de I'Hôpital, 75013 Paris, France
| |
Collapse
|
113
|
Mourgeon E, Levesque E, Duveau C, Law-Koune JD, Charbit B, Ternissien E, Coriat P, Rouby JJ. Factors influencing indoor concentrations of nitric oxide in a Parisian intensive care unit. Am J Respir Crit Care Med 1997; 156:1692-5. [PMID: 9372695 DOI: 10.1164/ajrccm.156.5.96-12012] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
In low concentrations, inhaled nitric oxide (NO) increases arterial oxygenation in patients with severe acute respiratory distress syndrome. When present in the ambient atmosphere, NO and its oxidative derivate, nitrogen dioxide (NO2), are considered pollutants. The aim of this study was to assess whether the administration of inhaled NO to mechanically ventilated patients was associated with an increased risk of exposure to NO and NO2 for medical and paramedical staff. During a 1-yr period, indoor and outdoor NO and NO2 concentrations were measured using chemiluminescence in a 14-bed intensive care unit (ICU) to assess the possible influence of therapeutic NO administration on indoor pollution. Ambient concentrations of NO within the ICU were 237 +/- 147 parts per billion (ppb) during periods of NO administration and 289 +/- 147 ppb during periods without NO administration (mean +/- SD, NS). Indoor concentrations of NO and NO2 were entirely dependent on outdoor concentrations and were mainly influenced by climatic conditions such as atmospheric pressure, mass of clouds, and speed of the wind. Therapeutic administration of concentrations of inhaled NO < or = 5 ppm to critically ill patients did not affect the ambient concentration of NO and NO2 within the ICU, which was mainly dependent on the outdoor air pollution. As a consequence, scavenging of exhaust NO from the breathing circuit in the ventilator does not appear mandatory in ICUs located in areas with significant urban pollution when NO concentrations < or = 5 ppm are administered.
Collapse
Affiliation(s)
- E Mourgeon
- Department of Anesthesiology, Faculté de Médecine Pitié-Salpétrière, University of Paris VI, France
| | | | | | | | | | | | | | | |
Collapse
|
114
|
Umamaheswara Rao GS, Gallart L, Law-Koune JD, Lu Q, Puybasset L, Cluzel P, Coriat P, Rouby JJ. Factors influencing the tracheal fluctuation of inhaled nitric oxide in patients with acute lung injury. Anesthesiology 1997; 87:823-34. [PMID: 9357884 DOI: 10.1097/00000542-199710000-00016] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND Inhaled nitric oxide (NO) improves arterial oxygenation in patients with acute lung injury (ALI) by selectively dilating pulmonary vessels perfusing ventilated lung areas. It can be hypothesized that NO uptake from the lung decreases with increasing ventilation perfusion mismatch. This study was undertaken to determine the factors influencing the fluctuation of tracheal NO concentration over the respiratory cycle as an index of NO pulmonary uptake in patients with ALI. METHODS By using a prototype system (Opti-NO) delivering a constant flow of NO only during the inspiratory phase, 3 and 6 ppm of NO were administered during controlled mechanical ventilation into a lung model and to 11 patients with ALI. All patients had a thoracic computed tomography (CT) scan. Based on an analysis of tomographic densities, lungs were divided into three zones: normally aerated (-1.000 to -500 Hounsfield units [HU]), poorly aerated (-500 to -100 HU), and nonaerated (-100 to +100 HU), and the volume of each zone was computed. Concentrations of NO in the inspiratory limb and trachea were continuously measured by a fast-response chemiluminescence apparatus. RESULTS In the lung model, tracheal NO concentration was stable with minor fluctuation. In contrast, in patients, tracheal NO concentration fluctuated widely during the respiratory cycle (55 +/- 10%). Because uptake of NO from the lungs was absent in the lung model but present in the patients, this fluctuation was considered as an index of pulmonary uptake of NO. This was further substantiated by (1) the coincidence of the peak and minimum tracheal NO concentration with the end-inspiratory and end-expiratory phases, respectively, and (2) continued decrease of tracheal NO concentration during prolonged expiratory phase. In patients with ALI, the fluctuation of tracheal NO concentration expressed as the difference between inspiratory and expiratory NO concentrations divided by inspiratory NO concentration was greater at 6 ppm than at 3 ppm (P < 0.01), was linearly correlated with normally aerated lung volume, inversely correlated with alveolar dead space and with poorly aerated lung volume. CONCLUSION In patients with ALI, fluctuation of tracheal NO concentration over the respiratory cycle can be considered as an index of NO uptake from the lungs that depends on aerated lung volume and perfusion of ventilated lung areas. At bedside, it may be used to follow the evolution of ventilation-perfusion mismatch.
Collapse
Affiliation(s)
- G S Umamaheswara Rao
- Unité de Réanimation Chirurgicale (Department of Anesthesiology), Hôpital de la Pitié-Salpétrière, University of Paris VI, France
| | | | | | | | | | | | | | | |
Collapse
|
115
|
Mourgeon E, Gallart L, Rao GS, Lu Q, Law-Koune JD, Puybasset L, Coriat P, Rouby JJ. Distribution of inhaled nitric oxide during sequential and continuous administration into the inspiratory limb of the ventilator. Intensive Care Med 1997; 23:849-58. [PMID: 9310802 DOI: 10.1007/s001340050421] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVES The concentrations of nitric oxide (NO) in the ventilatory circuits and the patient's airways were compared between sequential (SQA) and continuous (CTA) administration during inspiratory limb delivery. DESIGN Prospective controlled study. SETTING 14-bed Surgical Intensive Care Unit of a teaching University hospital. PATIENTS AND PARTICIPANTS Eleven patients with acute lung injury on mechanical ventilation and two healthy volunteers. INTERVENTIONS A prototype NO delivery device (Opti-NO) and César ventilator were set up in order to deliver 1, 3 and 6 parts per million (ppm) of NO into the bellows of a lung model in SQA and CTA. Using identical ventilatory and Opti-NO settings, NO was administered to the patients with acute lung injury. MEASUREMENTS AND RESULTS NO concentrations measured from the inspiratory limb [INSP-NOMeas] and the trachea [TRACH-NOMeas] using fast response chemiluminescence were compared between the lung model and the patients using controlled mechanical ventilation with a constant inspiratory flow. INSP-NOMeas were stable during SQA and fluctuated widely during CTA (fluctuation at 6 ppm = 61% in the lung model and 58 +/- 3% in patients). In patients, [TRACH-NOMeas] fluctuated widely during both modes (fluctuation at 6 ppm = 55 +/- 3% during SQA and 54 +/- 5% during CTA). The NO flow requirement was significantly lower during SQA than during CTA (74 +/- 0.5 vs 158 +/- 2.2 ml.min-1 to attain 6 ppm, p = 0.0001). INSP-NOMeas were close to the values predicted using a classical formula only during SQA (bias = -0.1 ppm, precision = +/-1 ppm during SQA; bias = 2.93 ppm and precision = +/-3.54 ppm during CTA). During SQA, INSP-NOMeas varied widely in healthy volunteers on pressure support ventilation. CONCLUSIONS CTA did not provide homogenous mixing of NO with the tidal volume and resulted in fluctuating INSP-NOMeas. In contrast, SQA delivered stable and predictable NO concentrations during controlled mechanical ventilation with a constant inspiratory flow and was economical compared to CTA. However, SQA did not provide stable and predictable NO concentrations during pressure support ventilation.
Collapse
Affiliation(s)
- E Mourgeon
- Département d'Anesthésie, Hôpital de la Pitié, Paris, France
| | | | | | | | | | | | | | | |
Collapse
|
116
|
Gallart L, Rouby JJ, Puig MM. [Pharmacologic treatment of hypoxemia in adult respiratory distress syndrome]. Rev Esp Anestesiol Reanim 1997; 44:273-83. [PMID: 9380921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
New drugs that improve arterial oxygenation (nitric oxide, almitrine, inhaled prostacyclin and cyclooxygenase inhibitors) are useful in the treatment of severe hypoxemia unresponsive to conventional treatment that is mainly seen in patients with acute respiratory distress syndrome (ARDS). By acting selectively on pulmonary blood flow and redistributing it, these drugs achieve effects unattainable until now. Thus, they decrease perfusion in non-ventilated zones (V/Q = O) responsible for shunt, or increase perfusion in well ventilated zones, guaranteeing adequate oxygenation. To apply these drugs the physician must understand their mechanism of action, guidelines for dosing, constraints on their use and side effects.
Collapse
Affiliation(s)
- L Gallart
- Servicio de Anestesiología y Reanimación, Hospital Universitari del Mar., Barcelona.
| | | | | |
Collapse
|
117
|
Kalfon P, Rao GS, Gallart L, Puybasset L, Coriat P, Rouby JJ. Permissive hypercapnia with and without expiratory washout in patients with severe acute respiratory distress syndrome. Anesthesiology 1997; 87:6-17; discussion 25A-26A. [PMID: 9232129 DOI: 10.1097/00000542-199707000-00003] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Permissive hypercapnia is a ventilatory strategy aimed at avoiding lung volutrauma in patients with severe acute respiratory distress syndrome (ARDS). Expiratory washout (EWO) is a modality of tracheal gas insufflation that enhances carbon dioxide removal during mechanical ventilation by reducing dead space. The goal of this prospective study was to determine the efficacy of EWO in reducing the partial pressure of carbon dioxide (PaCO2) in patients with severe ARDS treated using permissive hypercapnia. METHODS Seven critically ill patients with severe ARDS (lung injury severity score, 3.1 +/- 0.3) and no contraindications for permissive hypercapnia were studied. On the first day, hemodynamic and respiratory parameters were measured and the extent of lung hyperdensities was assessed using computed tomography. A positive end-expiratory pressure equal to the opening pressure identified on the pressure-volume curve was applied. Tidal volume was reduced until a plateau airway pressure of 25 cm H2O was reached. On the second day, after implementation of permissive hypercapnia, EWO was instituted at a flow of 15 l/min administered during the entire expiratory phase into the trachea through the proximal channel of an endotracheal tube using a ventilator equipped with a special flow generator. Cardiorespiratory parameters were studied under three conditions: permissive hypercapnia, permissive hypercapnia with EWO, and permissive hypercapnia. RESULTS During permissive hypercapnia, EWO decreased PaCO2 from 76 +/- 4 mmHg to 53 +/- 3 mmHg (-30%; P < 0.0001), increased pH from 7.20 +/- 0.03 to 7.34 +/- 0.04 (P < 0.0001), and increased PaO2 from 205 +/- 28 to 296 +/- 38 mmHg (P < 0.05). The reduction in PaCO2 was accompanied by an increase in end-inspiratory plateau pressure from 26 +/- 1 to 32 +/- 2 cm H2O (P = 0.001). Expiratory washout also decreased cardiac index from 4.6 +/- 0.4 to 3.7 +/- 0.3 l.min-1.m-2 (P < 0.01), mean pulmonary arterial pressure from 28 +/- 2 to 25 +/- 2 mmHg (P < 0.01), and true pulmonary shunt from 47 +/- 2 to 36 +/- 3% (P < 0.01). CONCLUSIONS Expiratory washout is an effective and easy-to-use ventilatory modality to reduce PaCO2 and increase pH during permissive hypercapnia. However, it significantly increases airway pressures and lung volume through expiratory flow limitation, reexposing some patients to a risk of lung volutrauma if the extrinsic positive end-expiratory pressure is not substantially reduced.
Collapse
Affiliation(s)
- P Kalfon
- Department of Anesthesiology, Hôpital de la Pitié-Salpétrièr, University of Paris VI, France
| | | | | | | | | | | |
Collapse
|
118
|
Mourgeon E, Puybasset L, Law-Koune JD, Lu Q, Abdennour L, Gallart L, Malassine P, Rao GSU, Cluzel P, Bennani A, Coriat P, Rouby JJ. Inhaled nitric oxide in acute respiratory distress syndrome with and without septic shock requiring norepinephrine administration: a dose-response study. Crit Care 1997; 1:25-39. [PMID: 11056694 PMCID: PMC28986 DOI: 10.1186/cc4] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/1996] [Revised: 04/19/1997] [Accepted: 06/09/1997] [Indexed: 01/20/2023] Open
Abstract
BACKGROUND: The aim of this prospective study was to assess whether the presence of septic shock could influence the dose response to inhaled nitric oxide (NO) in NO-responding patients with adult respiratory distress syndrome (ARDS). RESULTS: Eight patients with ARDS and without septic shock (PaO2 = 95 +/- 16 mmHg, PEEP = 0, FiO2 = 1.0), and eight patients with ARDS and septic shock (PaO2 = 88 +/- 11 mmHg, PEEP = 0, FiO2 = 1.0) receiving exclusively norepinephrine were studied. All responded to 15 ppm inhaled NO with an increase in PaO2 of at least 40 mmHg, at FiO2 1.0 and PEEP 10 cmH2O. Inspiratory intratracheal NO concentrations were recorded continuously using a fast response time chemiluminescence apparatus. Seven inspiratory NO concentrations were randomly administered: 0.15, 0.45, 1.5, 4.5, 15, 45 and 150 ppm. In both groups, NO induced a dose-dependent decrease in mean pulmonary artery pressure (MPAP), pulmonary vascular resistance index (PVRI), and venous admixture (QVA/QT), and a dose-dependent increase in PaO2/FiO2 (P </= 0.012). Dose-response of MPAP and PVRI were similar in both groups with a plateau effect at 4.5 ppm. Dose-response of PaO2/FiO2 was influenced by the presence of septic shock. No plateau effect was observed in patients with septic shock and PaO2/FiO2 increased by 173 +/- 37% at 150 ppm. In patients without septic shock, an 82 +/- 26% increase in PaO2/FiO2was observed with a plateau effect obtained at 15 ppm. In both groups, dose-response curves demonstrated a marked interindividual variability and in five patients pulmonary vascular effect and improvement in arterial oxygenation were dissociated. CONCLUSION: For similar NOinduced decreases in MPAP and PVRI in both groups, the increase in arterial oxygenation was more marked in patients with septic shock.
Collapse
Affiliation(s)
- Eric Mourgeon
- Unité de Réanimation Chirurgicale, Département d'Anesthésie, Hôpital de la Pitié-Salpétrière, 83 Boulevard de I'Hôpital, 75013 Paris, France
| | - Louis Puybasset
- Unité de Réanimation Chirurgicale, Département d'Anesthésie, Hôpital de la Pitié-Salpétrière, 83 Boulevard de I'Hôpital, 75013 Paris, France
| | - Jean-Dominique Law-Koune
- Unité de Réanimation Chirurgicale, Département d'Anesthésie, Hôpital de la Pitié-Salpétrière, 83 Boulevard de I'Hôpital, 75013 Paris, France
| | - Qin Lu
- Unité de Réanimation Chirurgicale, Département d'Anesthésie, Hôpital de la Pitié-Salpétrière, 83 Boulevard de I'Hôpital, 75013 Paris, France
| | - Lamine Abdennour
- Unité de Réanimation Chirurgicale, Département d'Anesthésie, Hôpital de la Pitié-Salpétrière, 83 Boulevard de I'Hôpital, 75013 Paris, France
| | - Lluis Gallart
- Unité de Réanimation Chirurgicale, Département d'Anesthésie, Hôpital de la Pitié-Salpétrière, 83 Boulevard de I'Hôpital, 75013 Paris, France
| | - Patrick Malassine
- Unité de Réanimation Chirurgicale, Département d'Anesthésie, Hôpital de la Pitié-Salpétrière, 83 Boulevard de I'Hôpital, 75013 Paris, France
| | - GS Umamaheswara Rao
- Unité de Réanimation Chirurgicale, Département d'Anesthésie, Hôpital de la Pitié-Salpétrière, 83 Boulevard de I'Hôpital, 75013 Paris, France
| | - Philippe Cluzel
- Département de Radiologie, Hôpital de la Pitié-Salpétrière, 83 Boulevard de I'Hôpital, 75013 Paris, France
| | - Abdelhai Bennani
- Laboratoire de Biologie, Hôpital de la Pitié-Salpétrière, 83 Boulevard de I'Hôpital, 75013 Paris, France
| | - Pierre Coriat
- Unité de Réanimation Chirurgicale, Département d'Anesthésie, Hôpital de la Pitié-Salpétrière, 83 Boulevard de I'Hôpital, 75013 Paris, France
| | - Jean-Jacques Rouby
- Unité de Réanimation Chirurgicale, Département d'Anesthésie, Hôpital de la Pitié-Salpétrière, 83 Boulevard de I'Hôpital, 75013 Paris, France
| |
Collapse
|
119
|
Affiliation(s)
- J J Rouby
- Department of Anesthesiology, Hôpital Pitié-Salpétrière, Paris, France
| |
Collapse
|
120
|
Rouby JJ. Histology and microbiology of ventilator-associated pneumonias. Semin Respir Infect 1996; 11:54-61. [PMID: 8885062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
A good knowledge of histological and bacteriological characteristics of experimental and human ventilator-associated bronchopneumonias (BPN) is of critical importance for the intensivist. BPN can be experimentally produced by intratracheal inoculation of microorganisms in high concentrations and ventilator-associated BPN by ventilating baboons with oleic-acid lung injury. Experimental ventilator-associated BPN is frequently polymicrobial, and bacterial lung burden increases with the severity of lung infection. In human ventilator-associated BPN, gross examination is of poor value for diagnosing lung infection. Four histologic categories of increasing severity have been described: bronchiolitis, focal bronchopneumonia, confluent bronchopneumonia, and lung abscess. Nonspecific inflammatory lesions are always associated with histologic lung infection: primary lung infection causes secondary inflammatory lung damage, whereas non-specific alveolar injury is rapidly superinfected when the lungs are mechanically ventilated. Infectious pulmonary lesions are disseminated within all pulmonary segments but preferentially found in the dependent segments. This fact suggests that ventilator-associated BPN has a bronchogenic origin and that gravity plays an important role in the dissemination of microorganisms within lung parenchyma. Ventilator-associated BPN is a nosocomial infection with a predominance of gram-negative bacteria, staphylococci species, and yeasts. It is frequently polymicrobial, and the lung bacterial burden depends on the histologic grade, the administration of topical and intravenous antibiotics, and the host's local antibacterial defenses. The bacterial complexity of human lung infection does not support the concept of a threshold for the diagnosis of nosocomial BPN. Intensivists should always keep in mind that human ventilator-associated BPN is a complex and rapidly changing entity.
Collapse
Affiliation(s)
- J J Rouby
- Department of Anesthesiology, Hôpital de la Pitié-Salpétrière, Université Paris VI, France
| |
Collapse
|
121
|
Bierling P, Godeau B, Fromont P, Bettaieb A, Debili N, el-Kassar N, Rouby JJ, Vainchenker W, Duedari N. Posttransfusion purpura-like syndrome associated with CD36 (Naka) isoimmunization. Transfusion 1995; 35:777-82. [PMID: 7570941 DOI: 10.1046/j.1537-2995.1995.35996029165.x] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
BACKGROUND CD36 deficiency, which could lead to CD36 isoimmunization, has been reported in the Japanese population. CD36 isoantibody has been involved in platelet transfusion refractoriness. CASE REPORT A 50-year-old woman originally from Corsica developed severe acute thrombocytopenia after massive transfusion. She was found to be CD36 deficient, and platelet immunoassays revealed a CD36 (Naka) platelet isoantibody. Although the involvement of another mechanism could not be entirely ruled out, the thrombocytopenia was attributed to posttransfusion purpura-like syndrome. The antibody was also involved in platelet transfusion refractoriness. CD36 deficiency was present in two members of the patient's family as well. Flow cytometry studies demonstrated the absence of CD36 expression on the surface of blood monocytes and cultured erythroblasts and megakaryocytes from one of the two CD36-deficient family members studied, but, in the absence of previous immunization, these CD36-deficient patients were not isoimmunized. In contrast, CD36 deficiency was not found in a population of 808 healthy blood donors in the Paris, France, area. CONCLUSION CD36 isoantibody might be involved in some cases of posttransfusion purpura and platelet transfusion refractoriness. These findings also confirm the extremely low frequency of CD36 deficiency among whites.
Collapse
Affiliation(s)
- P Bierling
- Laboratoire d'Immunologie Leucoplaquettaire, Hôpital Henri Mondor, Créteil, France
| | | | | | | | | | | | | | | | | |
Collapse
|
122
|
Fellahi JL, Mourgeon E, Goarin JP, Law-Koune JD, Riou B, Coriat P, Rouby JJ. Inhaled nitric oxide-induced closure of a patent foramen ovale in a patient with acute respiratory distress syndrome and life-threatening hypoxemia. Anesthesiology 1995; 83:635-8. [PMID: 7661369 DOI: 10.1097/00000542-199509000-00028] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Affiliation(s)
- J L Fellahi
- Department of Anesthesiology, Hôpital de la Pitié-Salpétrière, Université Paris VI, France
| | | | | | | | | | | | | |
Collapse
|
123
|
Saada M, Goarin JP, Riou B, Rouby JJ, Jacquens Y, Guesde R, Viars P. Systemic gas embolism complicating pulmonary contusion. Diagnosis and management using transesophageal echocardiography. Am J Respir Crit Care Med 1995; 152:812-5. [PMID: 7633748 DOI: 10.1164/ajrccm.152.2.7633748] [Citation(s) in RCA: 64] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
Systemic air embolism has been frequently reported after penetrating thoracic trauma. In blunt thoracic trauma, systemic air embolism has been rarely diagnosed, and then only after an invasive procedure such as thoracotomy. Transesophageal echocardiography has been recently introduced for the early assessment of trauma patients and is considered a sensitive noninvasive procedure to diagnose air embolism. We report three cases of systemic air embolism in patients with pulmonary contusion secondary to a blunt thoracic trauma requiring controlled ventilation. Transesophageal echocardiography was performed for evaluation of hemodynamic instability, and it showed air bubbles in the left atrium and left ventricle during the insufflation phase, which disappeared during apnea. A decrease in airway pressure (release of PEEP, low tidal volume, high frequency jet ventilation) significantly reduced the systemic air embolism. We concluded that systemic air embolism can occur after blunt thoracic trauma, and transesophageal echocardiography enables a rapid and accurate diagnosis that may be useful for therapeutic management.
Collapse
Affiliation(s)
- M Saada
- Department of Anesthesiology and Critical Care, Groupe Hospitalier Pitié-Salpêtrière, Paris VI University, France
| | | | | | | | | | | | | |
Collapse
|
124
|
Samama CM, Diaby M, Fellahi JL, Mdhafar A, Eyraud D, Arock M, Guillosson JJ, Coriat P, Rouby JJ. Inhibition of platelet aggregation by inhaled nitric oxide in patients with acute respiratory distress syndrome. Anesthesiology 1995; 83:56-65. [PMID: 7605019 DOI: 10.1097/00000542-199507000-00007] [Citation(s) in RCA: 126] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
BACKGROUND Nitric oxide inhibits platelet adhesion and aggregation in vitro. The aim of this prospective study was to assess the platelet antiaggregating activity of nitric oxide administered to patients with acute respiratory distress syndrome (ARDS) at increasing concentrations. METHODS In six critically ill patients (mean age 37 +/- 16 yr) with ARDS (lung injury severity score > or = 2.2), the lungs were mechanically ventilated with inhaled nitric oxide (1, 3, 10, 30, and 100 ppm) randomly administered. Patients with cardiac dysrhythmias, septic shock, an underlying hemostasis disorder (constitutive or acquired), a platelet count less than 100 Giga/l, or a decreased platelet aggregation and those treated with antiplatelet or anticoagulant agents were excluded. Platelet aggregation was measured without nitric oxide and at each nitric oxide concentration in platelet-rich plasma issued from radial artery. Ivy bleeding time using a horizontal incision was simultaneously performed. RESULTS After nitric oxide, a non-dose-dependent but statistically significant decrease in ex vivo platelet aggregation induced by three aggregating agents was observed: adenosine diphosphate = -56 +/- 18%, collagen = -37 +/- 18%, and ristocetin = -45 +/- 18% (P < 0.05). In each individual, Ivy bleeding time remained within normal values measured in healthy volunteers, and variations after nitric oxide did not correlate with changes in platelet aggregation. Simultaneously, arterial oxygenation improved significantly and pulmonary artery pressure decreased significantly. CONCLUSIONS In patients with ARDS and without preexisting coagulation disorders, the beneficial effects of inhaled nitric oxide on arterial oxygenation and pulmonary circulation are associated with a significant inhibition of platelet aggregation. This antithrombotic effect is not associated with a significant prolongation of the bleeding time.
Collapse
Affiliation(s)
- C M Samama
- Département d'Anesthésiologie, Hôpital de la Pitié-Salpêtrière, Université Paris VI, France
| | | | | | | | | | | | | | | | | |
Collapse
|
125
|
Puybasset L, Rouby JJ, Mourgeon E, Cluzel P, Souhil Z, Law-Koune JD, Stewart T, Devilliers C, Lu Q, Roche S. Factors influencing cardiopulmonary effects of inhaled nitric oxide in acute respiratory failure. Am J Respir Crit Care Med 1995; 152:318-28. [PMID: 7599840 DOI: 10.1164/ajrccm.152.1.7599840] [Citation(s) in RCA: 100] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
The aim of this prospective study was to determine factors influencing effects of inhaled nitric oxide (NO) on the pulmonary circulation and on gas exchange in critically ill patients with acute lung injury. Twenty-one hypoxemic patients with acute respiratory failure (PaO2 = 127 +/- 69 mm Hg during intermittent positive pressure ventilation, FiO2 = 1), were mechanically ventilated with 2 ppm NO and pure oxygen. The effect of positive end-expiratory pressure (PEEP) on alveolar recruitment was assessed on an anatomic basis using a high-resolution and spiral thoracic computed tomographic (CT) scan. Four conditions were studied in random order: zero end-expiratory pressure (ZEEP), ZEEP + 2 ppm NO, 10 cm H2O PEEP, 10 cm H2O PEEP + 2 ppm NO. During ZEEP and PEEP, NO significantly decreased pulmonary vascular resistance index (PVRI), mean pulmonary arterial pressure (MPAP), true pulmonary shunt (Qs/QT), and alveolar dead space (VDA/VT) and significantly increased PaO2 (p < 0.01). During ZEEP, NO-induced decreases in PVRI (delta PVRI) and MPAP (delta MPAP) were significantly correlated to baseline PVRI and MPAP (delta PVRI = -0.5 PVRI + 125, r = 0.97, p < 0.01 and delta MPAP = -0.28 MPAP + 4.8, r = 0.69, p < 0.05). These changes were not potentiated by PEEP-induced alveolar recruitment. The NO-induced increase in PaO2 (delta PaO2) was not significantly correlated with baseline PaO2 but was correlated with baseline PVRI (delta PaO2 = 0.11 PVRI + 30, r = 0.67, p < 0.05). In patients in whom PEEP was associated with alveolar recruitment, NO increased PaO2 by 66 +/- 24 mm Hg during ZEEP and by 104 +/- 26 mm Hg during PEEP (p < 0.01). In patients in whom PEEP did not induce alveolar recruitment, the NO-induced increase in PaO2 was similar during ZEEP and PEEP conditions (+70 +/- 15 mm Hg versus +76 +/- 12 mm Hg, NS). In patients with adult respiratory distress syndrome, factors determining NO-induced improvement in arterial oxygenation and pulmonary vascular effects are PEEP-induced alveolar recruitment and the baseline level of pulmonary vascular resistance.
Collapse
Affiliation(s)
- L Puybasset
- Department of Anesthesiology. Hôpital de la Pitié-Salpétrière, University of Paris VI, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
126
|
Rouby JJ, Laurent P, Gosnach M, Cambau E, Lamas G, Zouaoui A, Leguillou JL, Bodin L, Khac TD, Marsault C. Risk factors and clinical relevance of nosocomial maxillary sinusitis in the critically ill. Am J Respir Crit Care Med 1994; 150:776-83. [PMID: 8087352 DOI: 10.1164/ajrccm.150.3.8087352] [Citation(s) in RCA: 206] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
The incidence of infectious maxillary sinusitis (IMS) and its clinical relevance was prospectively studied in 162 consecutive critically ill patients who were mechanically ventilated for a period longer than 7 d. All had a paranasal computed tomographic (CT) scan within 48 h of admission and were divided into three groups according to the radiologic aspect of their maxillary sinuses: Group 1 = normal maxillary sinuses (n = 40), Group 2 = maxillary mucosal thickening (n = 26), Group 3 = radiologic maxillary sinusitis (RMS) defined as the presence of an air fluid level and/or opacification of maxillary sinuses (n = 96). Group 1 patients were randomized between nasal and oral endotracheal intubation with a gastric intubation performed via the same route and had a second paranasal CT scan 7 d later. Endotracheal and gastric tubes were left in their original position in Group 2 patients and a second paranasal CT scan was performed 7 d later. All patients of Group 3 underwent a transnasal puncture for bacteriologic analysis of maxillary sinus content. Forty-five spontaneously breathing patients served as a control group. In all patients with RMS, the occurrence of bronchopneumonia (BPN) was prospectively assessed for 7 d following the initial CT scan. Upon inclusion, only 25% of the patients had normal maxillary sinuses whereas all patients in the control group had normal paranasal CT scans. After 7 d, 46% of Group 2 patients had evidence of RMS. Risk factors for RMS were nasal placement and duration of endotracheal and gastric intubation.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- J J Rouby
- Unité de Réanimation Chirurgicale (Department of Anesthesiology), Hôpital de la Pitié-Salpétrière, Université Paris VI, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
127
|
Godet G, Bertrand M, Rouby JJ, Coriat P, Hag B, Kieffer E, Viars P. High-frequency jet ventilation vs continuous positive airway pressure for differential lung ventilation in patients undergoing resection of thoracoabdominal aortic aneurysm. Acta Anaesthesiol Scand 1994; 38:562-8. [PMID: 7976146 DOI: 10.1111/j.1399-6576.1994.tb03952.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Twenty patients, scheduled for surgical resection of thoracoabdominal aortic aneurysm were divided into two groups according to the type of differential lung ventilation used during graft replacement of the descending thoracic aorta. In the high-frequency jet ventilation (HFJV) group of ten patients, HFJV was applied to the left lung once collapsed and retracted by the surgeon, the patient lying in the right lateral decubitus and being intubated by a Carlens' tube. In the continuous positive airway pressure (CPAP) group of ten patients, CPAP was applied to the left lung at the same mean airway pressure as HFJV (1 kPa). Before anaesthetic induction, an arterial and a Swan-Ganz catheter were inserted for cardiovascular monitoring. The same anaesthetic technique using fentanyl 6 micrograms.kg-1, flunitrazepam 0.02 mg.kg-1 and pancuronium 0.1 mg.kg-1 was used for each patient. Haemodynamic and respiratory measurements were made; 15 min after positioning the patients in the right lateral decubitus using two-lung ventilation; 15 min after collapse and retraction of the left lung using one-lung ventilation and 15 min after using differential lung ventilation with CPAP or HFJV. Left lung collapse with conventional one-lung ventilation induced a dramatic decrease in arterial oxygenation: PaO2/FIO2 ratio decreased from 43 +/- 6 kPa to 20 +/- 8 kPa, alveolo-arterial oxygen difference increased from 24 +/- 7 kPa to 72 +/- 11 kPa and pulmonary shunt increased from 17 +/- 2% to 37 +/- 3%. Whereas differential lung ventilation with CPAP did not improve any of the respiratory parameters measured, differential lung ventilation with HFJV, significantly increased PaO2/FIO2 ratio to 41 +/- 14 kPa.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- G Godet
- Department of Anaesthesiology, University Hospital Center, Pitie-Salpetriere, Paris University, France
| | | | | | | | | | | | | |
Collapse
|
128
|
Puybasset L, Stewart T, Rouby JJ, Cluzel P, Mourgeon E, Belin MF, Arthaud M, Landault C, Viars P. Inhaled nitric oxide reverses the increase in pulmonary vascular resistance induced by permissive hypercapnia in patients with acute respiratory distress syndrome. Anesthesiology 1994; 80:1254-67. [PMID: 8010472 DOI: 10.1097/00000542-199406000-00013] [Citation(s) in RCA: 117] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
BACKGROUND The aim of this prospective study was to determine if inhaled nitric oxide (NO) would reverse the increase in pulmonary arterial pressures and in pulmonary vascular resistance induced by acute permissive hypercapnia in patients with acute respiratory distress syndrome. METHODS In 11 critically ill patients (mean age 59 +/- 22 yr) with acute respiratory distress syndrome (Murray Score > or = 2.5), the lungs were mechanically ventilated with NO 2 ppm during both normocapnic and hypercapnic conditions. Four phases were studied: normocapnia (arterial carbon dioxide tension 38 +/- 6 mmHg, tidal volume (655 +/- 132 ml); normocapnia plus inhaled NO 2 ppm; hypercapnia (arterial carbon dioxide tension 65 +/- 15 mmHg, tidal volume 330 +/- 93 ml); and hypercapnia plus inhaled NO 2 ppm. Continuous recordings were made of heart rate, arterial pressure, pulmonary artery pressure, tracheal pressure, and tidal volume (by pneumotachograph). At the end of each condition, arterial pressure, pulmonary artery pressure, cardiac filling pressures, and cardiac output were measured. Simultaneous arterial and mixed venous blood samples were obtained to measure arterial oxygen tension, arterial carbon dioxide tension, mixed venous oxygen tension, arterial hemoglobin oxygen saturation, mixed venous hemoglobin oxygen saturation, pH, and blood hemoglobin and methemoglobin concentrations (by hemoximeter). In addition, plasma concentrations of catecholamines were measured with a radioenzymatic assay. In 5 patients, end-tidal carbon dioxide tension was measured with a nonaspirative infrared capnometer. Calculations were made of pulmonary vascular resistance index, systemic vascular resistance index, true pulmonary shunt, and alveolar dead space. RESULTS During hypercapnia, NO decreased pulmonary vascular resistance index from 525 +/- 223 to 393 +/- 142 dyn.s.cm-5.m-2 (P < 0.01), a value similar to that measured in normocapnic conditions (391 +/- 122 dyn.s.cm-5.m-2). It also reduced mean pulmonary artery pressure from 40 +/- 9 to 35 +/- 8 mmHg (P < 0.01). NO increased arterial oxygen tension (inspired oxygen fraction 1) from 184 +/- 67 to 270 +/- 87 mmHg during normocapnia and from 189 +/- 73 to 258 +/- 101 mmHg during hypercapnia (P < 0.01). NO decreased true pulmonary shunt during normocapnia (from 34 +/- 3% to 28 +/- 4%, P < 0.001) but had no significant effect on it during hypercapnia (39 +/- 7% vs. 38 +/- 8.5%). In five patients, NO resulted in a decrease in alveolar dead space from 34 +/- 7% to 28 +/- 10% in normocapnic conditions and from 30 +/- 9% to 22 +/- 10% in hypercapnic conditions (P < 0.05). CONCLUSIONS Inhaled NO completely reversed the increase in pulmonary vascular resistance index induced by acute permissive hypercapnia. It only partially reduced the pulmonary hypertension induced by acute permissive hypercapnia, probably because the flow component of the increase in pulmonary pressure (i.e., the increase in cardiac output) was not reduced by inhaled NO. A significant increase in arterial oxygenation after NO administration was observed during normocapnic and hypercapnic conditions. A ventilation strategy combining permissive hypercapnia and inhaled NO may reduce the potentially deleterious effects that permissive hypercapnia alone has on lung parenchyma and pulmonary circulation.
Collapse
Affiliation(s)
- L Puybasset
- Unité de Réanimation Chirurgicale (Department of Anesthesiology), Hôpital de la Pitié-Salpétrière, University of Paris VI, France
| | | | | | | | | | | | | | | | | |
Collapse
|
129
|
Puybasset L, Rouby JJ, Mourgeon E, Stewart TE, Cluzel P, Arthaud M, Poète P, Bodin L, Korinek AM, Viars P. Inhaled nitric oxide in acute respiratory failure: dose-response curves. Intensive Care Med 1994; 20:319-27. [PMID: 7930025 DOI: 10.1007/bf01720903] [Citation(s) in RCA: 155] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
OBJECTIVE To determine the dose-response curve of inhaled nitric oxide (NO) in terms of pulmonary vasodilation and improvement in PaO2 in adults with severe acute respiratory failure. DESIGN Prospective randomized study. SETTING A 14-bed ICU in a teaching hospital. PATIENTS 6 critically ill patients with severe acute respiratory failure (lung injury severity score > or = 2.5) and pulmonary hypertension. INTERVENTIONS 8 concentrations of inhaled NO were administered at random: 100, 400, 700, 1000, 1300, 1600, 1900 and 5000 parts per billion (ppb). Control measurements were performed before NO inhalation and after the last concentration administered. After an NO exposure of 15-20 min, hemodynamic parameters obtained from a fiberoptic Swan-Ganz catheter, blood gases, methemoglobin blood concentrations and intratracheal NO and nitrogen dioxide (NO2) concentrations, continuously monitored using a bedside chemiluminescence apparatus, were recorded on a Gould ES 1000 recorder. In 2 patients end-tidal CO2 was also recorded. RESULTS The administration of 100-2000 ppb of inhaled NO induced: i) a dose-dependent decrease in pulmonary artery pressure and in pulmonary vascular resistance (maximum decrease--25%); ii) a dose-dependent increase in PaO2 via a dose-dependent reduction in pulmonary shunt; iii) a slight but significant decrease in PaCO2 via a reduction in alveolar dead space; iv) a dose-dependent increase in mixed venous oxygen saturation (SVO2). Systemic hemodynamic variables and methemoglobin blood concentrations did not change. Maximum NO2 concentrations never exceeded 165 ppb. In 2 patients, 91% and 74% of the pulmonary vasodilation was obtained for inhaled NO concentrations of 100 ppb. CONCLUSION In hypoxemic patients with pulmonary hypertension and severe acute respiratory failure, therapeutic inhaled NO concentrations are in the range 100-2000 ppb. The risk of toxicity related to NO inhalation is therefore markedly reduced. Continuous SVO2 monitoring appears useful at the bedside for determining optimum therapeutic inhaled NO concentrations in a given patient.
Collapse
Affiliation(s)
- L Puybasset
- Department of Anesthesiology, Université Paris VI, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
130
|
Rouby JJ, Poète P, Martin de Lassale E, Nicolas MH, Bodin L, Jarlier V, Korinek AM, Viars P. Prevention of gram negative nosocomial bronchopneumonia by intratracheal colistin in critically ill patients. Histologic and bacteriologic study. Intensive Care Med 1994; 20:187-92. [PMID: 8014284 DOI: 10.1007/bf01704698] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
OBJECTIVE To evaluate the efficiency of intratracheal colistin in preventing nosocomial bronchopneumonia (BPN) in the critically ill. DESIGN Study evaluating the clinical incidence of nosocomial BPN in 2 groups of critically ill patients who receive or did not receive intratracheal colistin. BPN was assessed clinically in survivors and histologically in non-survivors. SETTING A 14-bed surgical intensive care unit. PATIENTS 598 consecutive critically ill patients were studied during a prospective non-randomized study over a 40-month period. INTERVENTIONS 251 patients--31 non-survivors and 220 survivors--did not receive intratracheal colistin and 347-42 non-survivors and 305 survivors--received intratracheal colistin for a 2-week period (1,600,000 units per 24 h). MEASUREMENTS AND RESULTS The incidence of nosocomial BPN was evaluated clinically in survivors, using repeated protected minibronchoalveolar lavages, and histologically in non-survivors via an immediate postmortem pneumonectomy (histologic and semi-quantitative bacteriologic analysis of one lung). The clinical incidence of nosocomial BPN was of 37% in coli (-) survivors and of 27% in coli (+) survivors (p < 0.01). This result was histologically confirmed in non-survivors, where the incidence of histologic BPN was of 61% in coli (-) patients and of 36% in coli (+) patients (p < 0.001). Emergence of BPN due to colistin-resistant micro-organisms was not observed. Because colistin was successful in preventing Gram-negative BPN and did not change the absolute number of Gram-positive BPN, the proportion of BPN caused by staphylococcus species was higher in group coli (+) patients (33% vs 16%). Mortality was not significantly influenced by the administration of colistin. CONCLUSION This study suggests that the administration of intratracheal colistin during a 2-week period significantly reduces the incidence of Gram-negative BPN without creating an increasing number of BPN due to colistin-resistant micro-organisms.
Collapse
Affiliation(s)
- J J Rouby
- Département d'Anesthésie, Hôpital de la Pitié-Salpétrière, Université Paris VI, France
| | | | | | | | | | | | | | | |
Collapse
|
131
|
Rouby JJ. Bronchoalveolar lavage in the diagnosis of nosocomial pneumonia. Intensive Care World 1993; 10:145-50. [PMID: 10146455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
Affiliation(s)
- J J Rouby
- Département d'Anesthésie, Université Paris VI
| |
Collapse
|
132
|
Rouby JJ, Lherm T, Martin de Lassale E, Poète P, Bodin L, Finet JF, Callard P, Viars P. Histologic aspects of pulmonary barotrauma in critically ill patients with acute respiratory failure. Intensive Care Med 1993; 19:383-9. [PMID: 8270717 DOI: 10.1007/bf01724877] [Citation(s) in RCA: 134] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
OBJECTIVE To describe histologically pulmonary barotrauma in mechanically ventilated patients with severe acute respiratory failure. DESIGN Assessment of histologic pulmonary barotrauma. SETTING A 14-bed surgical intensive care unit (SICU) PATIENTS: The lungs of 30 young critically ill patients (mean age 34 +/- 10 years) were histologically examined in the immediate post-mortem period. None of them were suspected of pre-existing emphysema. MEASUREMENTS AND RESULTS Clinical events and ventilatory settings used during mechanical ventilation were compared with lung histology. Airspace enlargement, defined as the presence of either alveolar overdistension in aerated lung areas or intraparenchymal pseudocysts in nonaerated lung areas, was found in 26 of the 30 lungs examined (86%). Patients with severe airspace enlargement (2.6-40 mm internal diameter) had a significantly greater incidence of pneumothorax (8 versus 2, p < 0.05), were ventilated using higher peak airway pressures (56 +/- 18 cmH2O versus 44 +/- 10 cmH2O, p < 0.05) and tidal volumes (12 +/- 3 ml/kg versus 9 +/- 2 ml/kg, p < 0.05), were exposed significantly longer to toxic levels of oxygen (8.6 +/- 9.4 days versus 1.9 +/- 2 days at FIO2 > 0.6, p < 0.05) and lost more weight (6.3 +/- 9.2 kg versus 0.75 +/- 5.8 kg, p < 0.05) than patients with mild airspace enlargement (1-2.5 mm internal diameter). CONCLUSION Underlying histologic lesions responsible for clinical lung barotrauma consist of pleural cysts, bronchiolar dilatation, alveolar overdistension and intraprenchymal pseudocysts. Mechanical ventilation appears to be an aggravating factor, particularly when high peak airway pressures and large tidal volumes are delivered by the ventilator.
Collapse
Affiliation(s)
- J J Rouby
- Department of Anesthesiology, Hôpital de la Pitié-Salpêtrière, Université Paris VI, France
| | | | | | | | | | | | | | | |
Collapse
|
133
|
Orliaguet G, Jacquens Y, Riou B, Le Bret F, Rouby JJ, Viars P. Combined severe myocardial and pulmonary contusion: early diagnosis with transesophageal echocardiography and management with high-frequency jet ventilation: case report. J Trauma 1993; 34:455-457. [PMID: 8483194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
We report the case of a 27-year-old patient with blunt thoracic trauma in whom transesophageal echocardiography enabled an early diagnosis of severe myocardial contusion. Conventional mechanical ventilation dramatically enhanced cardiogenic shock because of myocardial contusion, requiring increasing doses of catecholamine. High-frequency jet ventilation produced an immediate improvement in hemodynamic status, permitting a decrease in catecholamine administration.
Collapse
Affiliation(s)
- G Orliaguet
- Department of Anesthesiology and Critical Care, C.H.U. Pitié-Salpêtriere, Paris, France
| | | | | | | | | | | |
Collapse
|
134
|
Rouby JJ, Martin De Lassale E, Poete P, Nicolas MH, Bodin L, Jarlier V, Le Charpentier Y, Grosset J, Viars P. Nosocomial bronchopneumonia in the critically ill. Histologic and bacteriologic aspects. Am Rev Respir Dis 1992; 146:1059-66. [PMID: 1416397 DOI: 10.1164/ajrccm/146.4.1059] [Citation(s) in RCA: 221] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
To provide a comprehensive description of the histologic and bacteriologic characteristics of human nosocomial bronchopneumonia (BPN), the lungs of 83 critically ill patients decreased after a period of mechanical ventilation were examined in the immediate postmortem period. In addition, the accuracy of the protected minibronchoalveolar lavage (BAL) technique in the diagnosis of nosocomial BPN was evaluated. In each patient, a surgical pneumonectomy was performed at the bedside within 30 min following death. Each pulmonary lobe was sampled and bacteriologically analyzed using semiquantitative cultures in 50 patients and quantitative cultures in 33 patients. The entire lung was histologically analyzed using 5 to 10 slices per lung segment. In 69 patients, the bacteriologic result of a protected mini-BAL performed within 48 h preceding death was compared with histologic and bacteriologic results of study of the lung tissue itself. Histologic lesions of BPN were found in 43 of the 83 lungs examined. These lesions were (1) severe in the majority of patients (confluent BPN, n = 23; lung abscess, n = 6), (2) preferentially found in dependent lung segments, (3) often associated with nonspecific alveolar damage, (4) associated with positive lung cultures in 65% of patients (53% with gram-negative bacteria), (5) polymicrobial in 28% of patients, (6) characterized by a lobar bacterial burden greater than 10(3) cfu/g in 32% of cases. Using semiquantitative bacteriologic analysis, the sensitivity and the specificity of the protected mini-BAL in the diagnosis of nosocomial BPN were found to be 70 and 69%, respectively. Protected mini-BAL identified 77% of causative microorganisms of BPN.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- J J Rouby
- Département d'Anesthésie (Unité de Réanimation Chirurgicale), Hôpital de la Pitié-Salpêtrière, Université Paris, VI, France
| | | | | | | | | | | | | | | | | |
Collapse
|
135
|
Rouby JJ, Ben Ameur M, Jawish D, Cherif A, Andreev A, Dreux S, Viars P. Continuous positive airway pressure (CPAP) vs. intermittent mandatory pressure release ventilation (IMPRV) in patients with acute respiratory failure. Intensive Care Med 1992; 18:69-75. [PMID: 1613201 DOI: 10.1007/bf01705035] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Intermittent Mandatory Pressure Release Ventilation (IMPRV) is a positive pressure spontaneous breathing ventilatory mode in which airway pressure is released intermittently and synchronously with patient's spontaneous expiration in order to provide ventilatory assistance. Eight critically ill patients free of any factor known to alter chest wall mechanics (group 1) and 8 critically ill patients whose spontaneous respiratory activity was markedly altered by a flail chest, or by a C5 quadraplegia and/or by the administration of opioids (group 2) were studied prospectively. CPAP and IMPRV were administered to each patient in a random order during a 1 h period using a CESAR ventilator. Gas flow, tidal volume, tracheal pressure, esophageal pressure, end-expiratory lung volume and hemodynamic parameters were measured. In group 1 patients, the ventilatory assistance provided by IMPRV was associated with a significant decrease in spontaneous tidal volume whereas all other respiratory parameters remained unchanged. In group 2 patients, IMPRV increased minute ventilation from 8.0 +/- 2.61/min to 12.2 +/- 1.81/min (p less than 0.05), decreased PaCO2 from 46 +/- 7.3 mmHg to 38 +/- 6.8 mmHg (p less than 0.05) and reduced respiratory frequency from 21 +/- 10 bpm to 14 +/- 5.7 bpm (p less than 0.07). These results show that IMPRV provides significant ventilatory assistance to patients with mild acute respiratory failure either by decreasing patient's contribution to minute ventilation or by increasing alveolar ventilation in presence of respiratory depression of central or peripheral origin.
Collapse
Affiliation(s)
- J J Rouby
- Département d'Anesthésie (Unité de Réanimation Chirurgicale) Hôpital de la Pitié, Université Paris VI, France
| | | | | | | | | | | | | |
Collapse
|
136
|
Rouby JJ, Andreev A, Léger P, Arthaud M, Landault C, Vicaut E, Maistre G, Eurin J, Gandjbakch I, Viars P. Peripheral vascular effects of thiopental and propofol in humans with artificial hearts. Anesthesiology 1991; 75:32-42. [PMID: 2064057 DOI: 10.1097/00000542-199107000-00007] [Citation(s) in RCA: 80] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
The peripheral vascular effects of thiopental 5 mg/kg and propofol 2.5 mg/kg were compared in five patients whose lungs were being ventilated and in whom a Jarvik-7 artificial heart had been implanted. The patients were monitored, using catheters that had been surgically inserted into the radial artery, the right and left atria, and the pulmonary artery. The Jarvik-7 settings were modified to render the artificial heart "preload independent" and to maintain cardiac output constant. Each patient received both drugs, with the interval between each drug ranging from 16 to 28 h. Hemodynamic parameters and catecholamine and atrial natriuretic peptide plasma concentrations were measured before drug administration and 5, 10, 15, 30, and 45 min later. Both drugs significantly decreased arterial pressure, systemic vascular resistance index, pulmonary arterial pressure (PAP), and right and left atrial pressures (RAP and LAP, respectively). However, propofol 2.5 mg/kg induced a significantly greater and more prolonged decrease in arterial pressure, systemic vascular resistance index, and RAP than that after administration of thiopental 5 mg/kg (P less than 0.05). Five minutes after drug injection, mean arterial pressure decreased by 21% after thiopental and by 39% after propofol (P less than 0.01); systemic vascular resistance index decreased by 21% after thiopental and by 44% after propofol (P less than 0.05); RAP decreased by 20% after thiopental and by 50% after propofol (P less than 0.05); mean PAP decreased by 18% after thiopental and by 32% after propofol (P less than 0.09); and LAP decreased by 40% after thiopental and by 46% after propofol (P less than 0.2). With both drugs, atrial natriuretic peptide, norepinephrine, and epinephrine plasma concentrations remained stable throughout the study period. Because cardiac output was maintained constant throughout the study, these results suggest that propofol 2.5 mg/kg is a more potent vasodilator of venous and arterial beds than is thiopental 5 mg/kg.
Collapse
Affiliation(s)
- J J Rouby
- Département d'Anesthésie, Hôpital de la Pitié, Paris, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
137
|
Amstutz P, Blanloeil Y, Cathala B, Chopin C, Gouin F, Grimaud D, Le Gall JR, Rouby JJ, Tempe JD, Vanooteghem-Delbarre A. [The results of antibiotic therapy in acute severe pneumonia dependent on the initial severity]. Presse Med 1990; 19:1948. [PMID: 2147761] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
|
138
|
Rouby JJ, Poète P, Bodin L, Bourgeois JL, Arthaud M, Viars P. Three mixed venous saturation catheters in patients with circulatory shock and respiratory failure. Chest 1990; 98:954-8. [PMID: 2209155 DOI: 10.1378/chest.98.4.954] [Citation(s) in RCA: 28] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Thirty-one critically ill patients with acute respiratory failure and circulatory shock were divided into three groups. Group 1 included 11 patients with an inserted mixed venous saturation (SvO2) catheter using three-reference wavelengths and characterized by one transmitting and one detecting fiberoptic filament (Oximetrix opticath catheter); group 2 included eight patients with an inserted SvO2 catheter using two-reference wavelengths and characterized by one transmitting and one detecting fiberoptic filament; (Edwards sat-one catheter); group 3 included 12 patients with an inserted SvO2 catheter using two-reference wavelengths and characterized by one transmitting and two detecting fiberoptic filaments. Once calibration procedures were performed, SvO2 measured by the catheter and by an hemoximeter OSM 3 (reference value) were compared following each therapeutic intervention. Over a period of 1.5 to 6 hours during which the hematocrit value remained unchanged, 119 measurements were obtained in group 1, 91 in group 2 and 181 in group 3. The dispersion of SvO2 values was much more pronounced with the two-reference wavelength systems using either one or two detecting fiber optic filaments, and the correlation coefficient was significantly higher with the three-reference wavelength system (r = 0.970 for the Oximetrix catheter vs r = 0.855 for the Edwards catheter and r = 0.826 for the Spectramed catheter, p less than 0.001). After 24 hours, the spontaneous drifts in the two-reference wavelength systems, using either one or two detecting fiber optic filaments (expressed as the SvO2 value measured by the catheter minus the reference SvO2 value) were significantly higher than the spontaneous drift in the three-reference wavelength system (9.3 +/- 7 percent for the Edwards catheter and +/- 6 +/- 4.1 percent for the Spectramed catheter vs 3.3 +/- 3.1 percent for the Oximetrix catheter, p less than 0.05). This study shows that a three-wavelength system is more accurate than a two-wavelength system for measuring acute changes in SvO2. The addition of a second detecting fiber optic filament does not seem to improve the accuracy of the system when SvO2 changes occur in conditions of stable hematocrit.
Collapse
Affiliation(s)
- J J Rouby
- Départment d'Anesthésie de la Pitié, Université Paris VI, France
| | | | | | | | | | | |
Collapse
|
139
|
Eurin J, Carayon A, Zongazo MA, Masson F, Barthelemy C, Maistre G, Rouby JJ, Eurin B, Legrand JC. Characteristics of atrial natriuretic hormone receptors in human pheochromocytomas. Acta Endocrinol (Copenh) 1990; 122:740-4. [PMID: 2165346 DOI: 10.1530/acta.0.1220740] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
The presence of functional receptors for human atrial natriuretic hormone in human pheochromocytomas was recently reported. The present study reports the binding of hANH as measured by Scatchard analysis in 4 human adrenal glands and in 5 human pheochromocytomas. Binding assays using [3H]ANH revealed a single class of high-affinity binding sites for hANH in both tissues. Human pheochromocytomas present a lower number of binding sites than normal human adrenal gland (Bmax of 7.1 +/- 2.1 vs 33.6 +/- 6.9 fmol/mg protein, respectively). However, the decreased number of ANH receptors was not paralleled by modifications of tissular cyclic GMP (cGMP). Moreover, plasma hANH concentrations in 7 patients with pheochromocytomas (20.2 +/- 2.7 pmol/l) were statistically higher than those obtained in 25 normal control humans (8.1 +/- 0.6 pmol/l, p less than 0.001). We also demonstrated the presence of immunoreactive ANH in the tumour itself.
Collapse
Affiliation(s)
- J Eurin
- Service de Biochimie, Faculté de médecine Pitié-Salpêtrière, Paris, France
| | | | | | | | | | | | | | | | | |
Collapse
|
140
|
Rouby JJ, Léger P, Andreev A, Arthaud M, Landau C, Vicaut E, Cabrol C, Viars P. Peripheral vascular effects of halothane and isoflurane in humans with an artificial heart. Anesthesiology 1990; 72:462-9. [PMID: 2310026 DOI: 10.1097/00000542-199003000-00012] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The peripheral vascular effects of isoflurane and halothane were compared in five critically ill patients in whom a Jarvik-7 artificial heart had been implanted. The lungs of all patients were mechanically ventilated in the postoperative period and the patients were monitored with an arterial catheter and with catheters that had been surgically inserted into the right and left atria and into the pulmonary artery. Norepinephrine and epinephrine plasma concentrations were measured using a radioenzymatic assay. The Jarvik-7 settings were modified to render the artificial heart "preload independent" and to maintain cardiac output constant. Each patient was anesthetized twice using halothane and isoflurane at two different MAC levels, 1 and 1.5 (Datex vapour analyzer), with the interval between each anesthetic ranging from 12 to 26 h. Both anesthetics significantly decreased mean arterial pressure (from 100 +/- 11 mmHg to 66 +/- 13 mmHg for halothane and from 102 +/- 17 mmHg to 48 +/- 11 mmHg for isoflurane; mean +/- SD) and systemic vascular resistance index (from 27 +/- 11 Wood units/m2 to 18 +/- 6 Wood units/m2 for halothane and from 30 +/- 6 Wood units/m2 to 13 +/- 3 Wood units/m2 for isoflurane; mean +/- SD), but with isoflurane to a significantly greater extent than with halothane (P less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- J J Rouby
- Département d'Anesthésie, Hopital de la Pitié, Université Paris VI, France
| | | | | | | | | | | | | | | |
Collapse
|
141
|
Rouby JJ. [High-frequency ventilation: status of research and practical application]. Rev Prat 1990; 40:456-7. [PMID: 2408132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- J J Rouby
- Département d'anesthesie-réanimation, CHU Pitié Salpêtrière, Paris
| |
Collapse
|
142
|
Rouby JJ, Rossignon MD, Nicolas MH, Martin de Lassale E, Cristin S, Grosset J, Viars P. A prospective study of protected bronchoalveolar lavage in the diagnosis of nosocomial pneumonia. Anesthesiology 1989; 71:679-85. [PMID: 2817462 DOI: 10.1097/00000542-198911000-00010] [Citation(s) in RCA: 142] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
The value of a new technique of protected bronchoalveolar lavage not requiring bronchoscopy was prospectively evaluated for the diagnosis of nosocomial pneumonia in two groups of critically ill patients. The control group was comprised of 29 patients free of any pulmonary disease whose lungs were ventilated for a mean time of 14 +/- 9 days (mean +/- SD). The pneumonia group was comprised of 30 patients with histologically proven nosocomial pneumonia whose lungs were ventilated for a mean time of 11 +/- 8 days. All patients of the pneumonia group died, and postmortem lung biopsies were taken for bacteriologic and pathologic examination. Twice a week in the control group or within the day preceding death in the pneumonia group, distal bronchial samples were obtained by a technique of protected bronchoalveolar lavage performed at the bedside. Fifty-one distal bronchial samples were bacteriologically analyzed in the control group and 30 in the pneumonia group. The sensitivity of a positive protected bronchoalveolar lavage for diagnosing nosocomial pneumonia was 80%, whereas the specificity was 66%. In 73% of the patients of the pneumonia group, the microorganisms isolated in the protected bronchoalveolar lavage and in the lung culture were partially (16%) or completely in agreement (57%). Among the 43 microorganisms isolated in the lung cultures, 74% were recovered by the protected bronchoalveolar lavage technique. This study shows that the protected bronchoalveolar lavage is an accurate technique for the diagnosis of nosocomial pneumonia. Because the technique is simple, noninvasive, easily repeatable at the bedside, and enables gram staining, it represents an attractive alternative to the fiberoptic bronchoscopy technique using a plugged double-sheathed brush.
Collapse
Affiliation(s)
- J J Rouby
- Département d'Anesthésie, Hôpital de la Pitié, Université Paris VI, France
| | | | | | | | | | | | | |
Collapse
|
143
|
Rouby JJ, Leger P, Arthaud M, Devilliers C, Cabrol A, Gandjbakch I, Cabrol C, Viars P. Respiratory effects of the Jarvik-7 artificial heart. J Appl Physiol (1985) 1989; 66:1984-9. [PMID: 2732189 DOI: 10.1152/jappl.1989.66.4.1984] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
In five anesthetized patients with a Jarvik-7 artificial heart, pulmonary volume displacements generated by cardiogenic oscillations were measured using an indirect spirometric method. Consequences on gas exchange were also evaluated during a 15-min period of apnea by use of a tracheal insufflation of pure O2 at a constant flow rate of 20 l/min. The Jarvik-7 artificial heart generated a mean pulmonary volume displacement of 105 +/- 29 (SD) ml/heart beat. After 15 min of apnea, arterial PCO2 (PaCO2) significantly increased from 29 +/- 5 to 47 +/- 6 (SD) Torr. PaCO2 increased by 0.8 Torr/min from the 5th to the 15th min of apnea. Mean arterial PO2, mean pulmonary shunt, mean O2 consumption, and mean metabolic production of CO2 did not change significantly during the apnea period. Because cardiac output was kept constant during the study, O2 transport was adequately maintained throughout the apnea period. In patient 1, where the period of apnea was continued for 60 min, PaCO2 progressively increased until the 45th min and then remained stable at 61 Torr during the last 15 min of apnea. This "plateau" corresponded to an alveolar ventilation of 3,907 ml/min, representing 69% of the alveolar ventilation calculated during conventional mechanical ventilation. In conclusion, the Jarvik-7 artificial heart provides a potent respiratory support through the cardiogenic oscillations it generates.
Collapse
Affiliation(s)
- J J Rouby
- Department of Anesthesiology, University of Paris VI, Hôpital de la Pitié-Salpétrière, France
| | | | | | | | | | | | | | | |
Collapse
|
144
|
Rouby JJ, Bodin L, Bourgeois JL, Ourhama S, Arthaud M, Viars P. [Comparative evaluation of 2 fiber optic catheters for the continuous measurement of Svo2]. Ann Fr Anesth Reanim 1989; 8:672-6. [PMID: 2633666 DOI: 10.1016/s0750-7658(89)80189-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Nineteen intensive care patients with shock and acute respiratory failure were studied using two different fiber-optic catheters used for the continuous measurement of mixed venous blood oxygen saturation (SVO2). In groupe I patients (n = 11), a Swan-Ganz catheter with optic fibres emitting light characterized by three different wavelengths was used (Opticath Oximetrix). In groupe II patients (n = 8), a Sat-one Edwards catheter was used instead (only two different wavelengths). All the patients were studied in the early stages of shock, once all the calibration procedures had been carried out. An increase in FIO2, using PEEP, fluid replacement therapy and vasoactive drugs or diuretics all improved the cardio-respiratory status of each patient. After each new therapeutic procedure, SVO2 was measured in blood samples obtained from these catheters, and from the pulmonary artery (to give the reference value, using an OSM3 Hemoximeter). Over a period of 1.5 to 6 h, 119 measurements were carried out in Group I, and 91 in Group II. The correlation coefficient was higher with the Oximetrix catheter than with the Edwards one (r = 0.970 and 0.855 respectively; p less than 0.001). Moreover, the 24 h spontaneous drift of the former catheter was less than that of the latter (+3.3 +/- 3.1% vs. +9.3 +/- 7%, p less than 0.05). This study showed that a catheter with optic fibres emitting a light with three wavelengths is more accurate than one emitting only two for the measurement of changes in SVO2 in critically ill patients.
Collapse
Affiliation(s)
- J J Rouby
- Département d'Anesthésie, Unité de Réanimation Chirurgicale, Hôpital de la Pitié, Paris
| | | | | | | | | | | |
Collapse
|
145
|
Rouby JJ, Poète P, Bodin L, Bourgeois JL, Arthaud M, Devilliers C, Viars P. [Factors influencing mixed venous oxygen saturation in intensive care]. Ann Fr Anesth Reanim 1989; 8:703-7. [PMID: 2699177 DOI: 10.1016/s0750-7658(89)80195-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Changes in mixed venous blood oxygen saturation (SvO2) were studied in 2 groups of patients. Group I patients (n = 10) were all hypoxaemic, suffering from acute respiratory failure, requiring that FIO2 be maintained at 1 throughout the study; respiratory and haemodynamic conditions were improved using PEEP and cardiovascular support. On the other hand, Group II patients (n = 13) were non-hypoxaemic patients with circulatory shock in whom FIO2 was gradually increased, and the haemodynamic status was improved using positive inotropic drugs (dopamine, dobutamine, adrenaline, amrinone). All 23 patients had a Swan-Ganz catheter set up for monitoring; all the usual haemodynamic and respiratory parameters were measured. Haematocrit values were kept at the same level throughout the study. Haemodynamic parameters were measured each time a new therapeutic procedure was carried out. No close relationship between SvO2 changes and changes in cardiac index or O2 consumption were found. However, a close relationship existed between changes in SvO2 and changes in O2 extraction (EAO2): SvO2 = -EAO2 + 102 (Group I; r = 0.90, n = 54); SvO2 = -1.2 EAO2 + 103 (Group II; r = 0.93, n = 66). A strong relationship was also found between changes in SvO2 and in FIO2 in each patient of Group II. In the complicated physiological set-up of an intensive care patient, SvO2 reflects oxygen extraction. A fall in SvO2 is related to an altered oxygen demand: oxygen supply ratio. In the most seriously ill patients, there is no relationship between changes in SvO2 and cardiac index.
Collapse
Affiliation(s)
- J J Rouby
- Département d'Anesthésie, Unité de Réanimation Chirurgicale, Hôpital de la Pitié, Paris
| | | | | | | | | | | | | |
Collapse
|
146
|
Abstract
Fifty five patients suffering from blunt chest trauma were studied to assess the diagnosis of myocardial contusion using thallium 201 myocardial scintigraphy. Thirty-eight patients had consistent scintigraphic defects and were considered to have a myocardial contusion. All patients with scintigraphic defects had paroxysmal arrhythmias and/or ECG abnormalities. Of 38 patients, 32 had localized ST-T segment abnormalities; 29, ST-T segment abnormalities suggesting involvement of the same cardiac area as scintigraphic defects; 21, echocardiographic abnormalities. Sixteen patients had segmental hypokinesia involving the same cardiac area as the scintigraphic defects. Fifteen patients had clinical signs suggestive of myocardial contusion and scintigraphic defects. Almost 70 percent of patients with blunt chest trauma had scintigraphic defects related to areas of myocardial contusion. When thallium 201 myocardial scintigraphy directly showed myocardial lesion, two-dimensional echocardiography and standard ECG detected related functional consequences of cardiac trauma.
Collapse
Affiliation(s)
- L Bodin
- Département d'Anesthésie, Centre Hospitalo-Universitaire, Université Paris VI, France
| | | | | |
Collapse
|
147
|
Rouby JJ, Houissa M, Brichant JF, Baron JF, McMillan C, Arthaud M, Amzallag P, Viars P. Effects of high-frequency jet ventilation on arterial baroreflex regulation of heart rate. J Appl Physiol (1985) 1987; 63:2216-22. [PMID: 3325484 DOI: 10.1152/jappl.1987.63.6.2216] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
Fifteen anesthetized mechanically ventilated patients recovering from multiple trauma were studied to compare the effects of high-frequency jet ventilation (HFJV) and continuous positive-pressure ventilation (CPPV) on arterial baroreflex regulation of heart rate. Systolic arterial pressure and right atrial pressure were measured using indwelling catheters. Electrocardiogram (ECG) and mean airway pressure were continuously monitored. Lung volumes were measured using two linear differential transformers mounted on thoracic and abdominal belts. Baroreflex testing was performed by sequential intravenous bolus injections of phenylephrine (200 micrograms) and nitroglycerin (200 micrograms) to raise or lower systolic arterial pressure by 20-30 Torr. Baroreflex regulation of heart rate was expressed as the slope of the regression line between R-R interval of the ECG and systolic arterial pressure. In each mode of ventilation the ventilatory settings were chosen to control mean airway pressure and arterial PCO2 (PaCO2). In HFJV a tidal volume of 159 +/- 61 ml was administered at a frequency of 320 +/- 104 breaths/min, whereas in CPPV a tidal volume of 702 +/- 201 ml was administered at a frequency of 13 +/- 2 breaths/min. Control values of systolic arterial pressure, R-R interval, mean pulmonary volume above apneic functional residual capacity, end-expiratory pulmonary volume, right atrial pressure, mean airway pressure, PaCO2, pH, PaO2, and temperature before injection of phenylephrine or nitroglycerin were comparable in HFJV and CPPV. Baroreflex regulation of heart rate after nitroglycerin injection was significantly higher in HFJV (4.1 +/- 2.8 ms/Torr) than in CPPV (1.96 +/- 1.23 ms/Torr).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- J J Rouby
- Département d'Anesthésie de la Pitié-Salpêtrière, Centre Hospitalo-Universitaire Pitié-Salpêtrière, Université Paris VI, France
| | | | | | | | | | | | | | | |
Collapse
|
148
|
Benhamou D, Ecoffey C, Rouby JJ, Spielvogel C, Viars P. High frequency jet ventilation: the influence of different methods of injection on respiratory parameters. Br J Anaesth 1987; 59:1257-64. [PMID: 3676054 DOI: 10.1093/bja/59.10.1257] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Fourteen critically ill patients with ventilatory failure were ventilated with HFJV using a constant driving pressure of 3 atm and a constant I:E ratio of 0.43. In six (group I) HFJV, using a frequency of 100 b.p.m., was delivered via a proximal injector cannula. Four injector cannulae (i.d. 1.8, 1.6, 1.4 and 1.2 mm, respectively) were used at random. In eight patients (group II), HFJV using three frequencies (100, 300 and 600 b.p.m.) was administered either via a 1.8-mm i.d. proximal injector cannula (proximal injection), for via a Hi-Lo jet tracheal tube (distal injection). The following indices were measured in vivo: mean airway pressure (Paw), mean pulmonary volume above apnoeic FRC (delta V), mean alveolar pressure (clamps method) and arterial blood-gas tensions. Injected volume (Vinj), entrainment (E) and tidal volume (VT) were measured in vitro using a water-sealed spirometer. Operating pressure (the pressure in the connecting tube) was measured directly using a high pressure calibrated transducer. In group I, Paw, delta V, PaO2, Vinj and VT significantly decreased whereas operating pressure and E significantly increased when the internal diameter of the injector cannula was reduced. In group II, Paw, delta V, E, VT and operating pressure significantly decreased, whereas Vinj increased and PaO2 and PaCO2 remained unchanged, when proximal injection was switched to distal injection. In both groups, a significant relationship was found between operating pressure and E. At a constant driving pressure, operating pressure increased with narrow injector cannulae and increased frequency, and decreased when proximal injection was switched for distal injection.
Collapse
Affiliation(s)
- D Benhamou
- Département d'Anesthésie-Réanimation, Centre Hospitalo-Universitaire, Pitié-Salpétrière, Paris, France
| | | | | | | | | |
Collapse
|
149
|
Abstract
Pulmonary oedema during angiographically proved massive pulmonary embolism without left ventricular failure is unusual. A few previous reports have used haemodynamic data obtained during the acute phase to rule out left ventricular failure. The following case, which we were able to observe for a period of 4 years has given further evidence of uninvolved left ventricular function.
Collapse
Affiliation(s)
- M C Dombert
- Department of Internal Medicine, Hôpital Bichat, Paris
| | | | | | | | | | | |
Collapse
|
150
|
Rouby JJ, Viars P. [High frequency jet ventilation]. Presse Med 1987; 16:1538-41. [PMID: 2958820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
High frequency jet ventilation (HFJV) is a new ventilation technique which ensures satisfactory gas exchanges with tidal volumes of about 2 ml . kg-1. A gas mixture under high pressure is "chopped up" by an electrically-controlled solenoid valve and delivered to the patient by an injection system. A specific heater-humidifier is required for optimal humidity and warmth of the gas mixture. HFJV creates a positive end-expiratory pressure effect in the alveoles, and the increase of mean intratracheal pressure observed accurately reflects the increase of mean alveolar pressure. Convection by direct alveolar ventilation plays a determinant role in CO2 clearance under HFJV, the other gas transport mechanisms being accessory. In respiratory failure with shock HFJV is better tolerated haemodynamically than conventional ventilation. The main indications of the new technique are ENT surgery, thoracic and tracheal surgery, lithotripsy, broncho-pleural and oesophago-tracheal fistulae and circulatory shock.
Collapse
Affiliation(s)
- J J Rouby
- Département d'Anesthésie, CHU Pitié-Salpétrière, Paris
| | | |
Collapse
|