51
|
Riley EP, Thomas JD, Goodlett CR, Klintsova AY, Greenough WT, Hungund BL, Zhou F, Sari Y, Powrozek T, Li TK. Fetal alcohol effects: mechanisms and treatment. Alcohol Clin Exp Res 2001. [PMID: 11391059 DOI: 10.1111/j.1530-0277.2001.tb02384.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
This article represents the proceedings of a symposium at the 2000 ISBRA Meeting in Yokohama, Japan. The chair was Edward P. Riley. The presentations were (1) Does alcohol withdrawal contribute to fetal alcohol effects? by Jennifer D. Thomas and Edward P. Riley; (2) Brain damage and neuroplasticity in an animal model of binge alcohol exposure during the "third trimester equivalent," by Charles R. Goodlett, Anna Y. Klintsova, and William T. Greenough; (3) Ganglioside GM1 reduces fetal alcohol effects, by Basalingappa L. Hungund; and (4) Fetal alcohol exposure alters the wiring of serotonin system at mid-gestation, by F. Zhou, Y. Sari, Charles Goodlett, T. Powrozek, and Ting-Kai Li.
Collapse
|
52
|
McCarthy PM, Takagaki M, Ochiai Y, Young JB, Tabata T, Shiota T, Qin JX, Thomas JD, Mortier TJ, Schroeder RF, Schweich CJ, Fukamachi K. Device-based change in left ventricular shape: a new concept for the treatment of dilated cardiomyopathy. J Thorac Cardiovasc Surg 2001; 122:482-90. [PMID: 11547298 DOI: 10.1067/mtc.2001.115240] [Citation(s) in RCA: 72] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVE We tested a unique new device, the Myosplint device (Myocor, Inc, Maple Grove, Minn), which is designed to change left ventricular shape, reduce left ventricular wall stress, and improve left ventricular systolic function. METHODS Heart failure was induced in 15 dogs over 27 days by rapid pacing (230 beats/min). Seven animals underwent sham surgery, and 8 animals received 3 transventricular Myosplint devices each. Myosplint devices were tightened to create a symmetric bilobular left ventricular shape and were adjusted to produce a calculated 20% reduction in wall stress. Hemodynamic, 2-dimensional, and 3-dimensional echocardiographic studies were recorded at baseline, immediately after Myosplint placement (acute change), and at 1 month after both groups had a reduced rate (190 beats/min) of pacing designed to maintain heart failure. RESULTS The Myosplint group had significant sustained improvements in left ventricular ejection fraction from baseline, to the acute change, to 1 month (19% +/- 5%; 36% +/- 8%; 39% +/- 13%) and reductions of left ventricular end-systolic volumes (73 +/- 9 mL; 34 +/- 5 mL; 42 +/- 12 mL) and end-systolic wall stress by 39% (341 +/- 68 10(3) dynes x cm(- 2) to 206 +/- 28 10(3) dynes x cm(-2)) acutely and 31% (372 +/- 83 10(3) dynes x cm(-2) to 250 +/- 40 10(3) dynes x cm(-2)) at 1 month. There were no significant changes in mitral regurgitation. CONCLUSION Application of a Myosplint device to a dilated impaired left ventricle resulted in reduced wall stress and improved left ventricular systolic function that was sustained at 1 month. Device-based shape change is a promising new opportunity to treat patients with dilated cardiomyopathy.
Collapse
|
53
|
|
54
|
Tabata T, Grimm RA, Greenberg NL, Agler DA, Mowrey KA, Wallick DW, Zhang Y, Zhuang S, Mazgalev TN, Thomas JD. Assessment of LV systolic function in atrial fibrillation using an index of preceding cardiac cycles. Am J Physiol Heart Circ Physiol 2001; 281:H573-80. [PMID: 11454559 DOI: 10.1152/ajpheart.2001.281.2.h573] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The clinical assessment of left ventricular (LV) systolic function during atrial fibrillation (AF) is unreliable and difficult because of beat-to-beat variability. We evaluated an index for the estimation of LV systolic function in AF that is based on the relationship between the preceding (R-R1) and prepreceding (R-R2) R-R intervals. LV Doppler stroke volume (SV), ejection fraction (EF), peak aortic flow rate (AoF) and the maximum value of the first derivative of the LV pressure curve (dP/dt(max)) were evaluated in 13 healthy open-chest dogs during triggered AF. All parameters showed a significantly strong positive linear relationship with the ratio of R-R1/R-R2 (r = 0.65, 0.74, 0.75, and 0.70 for SV, EF, AoF, and dP/dt(max), respectively). The calculated value of LV systolic parameters at R-R1/R-R2 = 1 in the linear regression line showed a good relationship and an agreement with the measured average value of the parameter over all cardiac cycles (SV, 12.1 vs. 12.8 ml; EF, 49.6 vs. 51.2%; AoF, 1.37 vs. 1.48 l/min; and dP/dt(max), 2,323 vs. 2,454 mmHg/s). Using the LV systolic parameters estimated at R-R1/R-R2 = 1 in the linear regression line allows the LV contractile function to be accurately and reproducibly evaluated during AF and obviates the less-reliable process of averaging multiple cardiac cycles.
Collapse
|
55
|
Sitges M, Kapadia S, Rubin DN, Thomas JD, Tuzcu ME, Lever HM. Percutaneous transluminal alcohol septal myocardial ablation after aortic valve replacement. Catheter Cardiovasc Interv 2001; 53:524-6. [PMID: 11515006 DOI: 10.1002/ccd.1215] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
When left ventricular outflow tract obstruction develops after aortic valve replacement, few treatment choices have been available until now. We present a patient with prior aortic valve replacement who developed left ventricle outflow tract obstruction that was successfully treated with a percutaneous transcoronary myocardial septal alcohol ablation. This technique is a useful tool for the treatment of obstructive hypertrophic cardiomyopathy, especially in those patients with prior heart surgery.
Collapse
|
56
|
Bauer F, Shiota T, Thomas JD. [Real time 3D echocardiography]. ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX 2001; 94:690-5. [PMID: 11494630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
Abstract
Three-dimensional representation of the heart is an old concern. Usually, 3D reconstruction of the cardiac mass is made by successive acquisition of 2D sections, the spatial localisation and orientation of which require complex guiding systems. More recently, the concept of volumetric acquisition has been introduced. A matricial emitter-receiver probe complex with parallel data processing provides instantaneous of a pyramidal 64 degrees x 64 degrees volume. The image is restituted in real time and is composed of 3 planes (planes B and C) which can be displaced in all spatial directions at any time during acquisition. The flexibility of this system of acquisition allows volume and mass measurement with greater accuracy and reproducibility, limiting inter-observer variability. Free navigation of the planes of investigation allows reconstruction for qualitative and quantitative analysis of valvular heart disease and other pathologies. Although real time 3D echocardiography is ready for clinical usage, some improvements are still necessary to improve its conviviality. Then real time 3D echocardiography could be the essential tool for understanding, diagnosis and management of patients.
Collapse
|
57
|
De Mey S, Thomas JD, Greenberg NL, Vandervoort PM, Verdonck PR. Assessment of the time constant of relaxation: insights from simulations and hemodynamic measurements. Am J Physiol Heart Circ Physiol 2001; 280:H2936-43. [PMID: 11356655 DOI: 10.1152/ajpheart.2001.280.6.h2936] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The objective of this study was to use high-fidelity animal data and numerical simulations to gain more insight into the reliability of the estimated relaxation constant derived from left ventricular pressure decays, assuming a monoexponential model with either a fixed zero or free moving pressure asymptote. Comparison of the experimental data with the results of the simulations demonstrated a trade off between the fixed zero and the free moving asymptote approach. The latter method more closely fits the pressure curves and has the advantage of producing an extra coefficient with potential diagnostic information. On the other hand, this method suffers from larger standard errors on the estimated coefficients. The method with fixed zero asymptote produces values of the time constant of isovolumetric relaxation (tau) within a narrow confidence interval. However, if the pressure curve is actually decaying to a nonzero pressure asymptote, this method results in an inferior fit of the pressure curve and a biased estimation of tau.
Collapse
|
58
|
Bolhuis A, Mathers JE, Thomas JD, Barrett CM, Robinson C. TatB and TatC form a functional and structural unit of the twin-arginine translocase from Escherichia coli. J Biol Chem 2001; 276:20213-9. [PMID: 11279240 DOI: 10.1074/jbc.m100682200] [Citation(s) in RCA: 207] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
In Escherichia coli, a subset of periplasmic proteins is exported via the twin-arginine translocation (Tat) pathway. In the present study, we have purified the Tat complex from E. coli, and we show that it contains only TatA, TatB, and TatC. Within the purified complex, TatB and TatC are present in a strict 1:1 ratio, suggesting a functional association. This has been confirmed by expression of a translational fusion between TatB and TatC. This Tat(BC) chimera supports efficient Tat-dependent export, indicating that TatB and TatC act as a unit in both structural and functional terms. The purified Tat complex contains varying levels of TatA, suggesting a gradual loss during isolation and a looser association. The molecular mass of the complex is approximately 600 kDa, demonstrating the presence of multiple copies of TatA, B, and C. Co-immunoprecipitation experiments show that TatC is required for the interaction of TatA with TatB, suggesting that TatA may interact with the complex via binding to TatC.
Collapse
|
59
|
Sun JP, Asher CR, Yang XS, Cheng GG, Scalia GM, Massed AG, Griffin BP, Ratliff NB, Stewart WJ, Thomas JD. Clinical and echocardiographic characteristics of papillary fibroelastomas: a retrospective and prospective study in 162 patients. Circulation 2001; 103:2687-93. [PMID: 11390338 DOI: 10.1161/01.cir.103.22.2687] [Citation(s) in RCA: 295] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Cardiac papillary fibroelastoma (CPF) is a primary cardiac neoplasm that is increasingly detected by echocardiography. The clinical manifestations of this entity are not well described. METHODS AND RESULTS In a 16-year period, we identified patients with CPF from our pathology and echocardiography databases. A total of 162 patients had pathologically confirmed CPF. Echocardiography was performed in 141 patients with 158 CPFs, and 48 patients had CPFs that were not visible by echocardiography (<0.2 cm), leaving an echocardiographic subgroup of 93 patients with 110 CPFs. An additional 45 patients with a presumed diagnosis of CPF were identified. The mean age of the patients was 60+/-16 years of age, and 46.1% were male. Echocardiographically, the mean size of the CPFs was 9+/-4.6 mm; 82.7% occurred on valves (aortic more than mitral), 43.6% were mobile, and 91.4% were single. During a follow-up period of 11+/-22 months, 23 of 26 patients with a prospective diagnosis of CPF that was confirmed by pathological examination had symptoms that could be attributable to embolization. In the group of 45 patients with a presumed diagnosis of CPF, 3 patients had symptoms that were likely due to embolization (incidence, 6.6%) during a follow-up period of 552+/-706 days. CONCLUSIONS CPFs are generally small and single, occur most often on valvular surfaces, and may be mobile, resulting in embolization. Because of the potential for embolic events, symptomatic patients, patients undergoing cardiac surgery for other lesions, and those with highly mobile and large CPFs should be considered for surgical excision.
Collapse
|
60
|
Greenberg NL, Vandervoort PM, Firstenberg MS, Garcia MJ, Thomas JD. Estimation of diastolic intraventricular pressure gradients by Doppler M-mode echocardiography. Am J Physiol Heart Circ Physiol 2001; 280:H2507-15. [PMID: 11356605 DOI: 10.1152/ajpheart.2001.280.6.h2507] [Citation(s) in RCA: 121] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Previous studies have shown that small intraventricular pressure gradients (IVPG) are important for efficient filling of the left ventricle (LV) and as a sensitive marker for ischemia. Unfortunately, there has previously been no way of measuring these noninvasively, severely limiting their research and clinical utility. Color Doppler M-mode (CMM) echocardiography provides a spatiotemporal velocity distribution along the inflow tract throughout diastole, which we hypothesized would allow direct estimation of IVPG by using the Euler equation. Digital CMM images, obtained simultaneously with intracardiac pressure waveforms in six dogs, were processed by numerical differentiation for the Euler equation, then integrated to estimate IVPG and the total (left atrial to left ventricular apex) pressure drop. CMM-derived estimates agreed well with invasive measurements (IVPG: y = 0.87 x + 0.22, r = 0.96, P < 0.001, standard error of the estimate = 0.35 mmHg). Quantitative processing of CMM data allows accurate estimation of IVPG and tracking of changes induced by β-adrenergic stimulation. This novel approach provides unique information on LV filling dynamics in an entirely noninvasive way that has previously not been available for assessment of diastolic filling and function.
Collapse
|
61
|
Tabata T, Kabbani SS, Murray RD, Thomas JD, Abdalla I, Klein AL. Difference in the respiratory variation between pulmonary venous and mitral inflow Doppler velocities in patients with constrictive pericarditis with and without atrial fibrillation. J Am Coll Cardiol 2001; 37:1936-42. [PMID: 11401135 DOI: 10.1016/s0735-1097(01)01252-9] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVES The goal of this study was to evaluate the difference in the respiratory change from expiration to inspiration (%E) between pulsed Doppler mitral inflow (MV) and pulmonary venous flow (PV) velocities in patients with constrictive pericarditis (CP) and to describe the influence of atrial fibrillation (AF). BACKGROUND The difference in %E between MV and PV velocities as well as the influence of AF on %E has not been well described. METHODS Pulsed-wave Doppler transesophageal echocardiography (TEE) was performed with respiratory monitoring in 31 patients with CP and sinus rhythm (SR) and in 10 patients with CP and AF. The MV early (E) and late diastolic (A) velocities and their velocity time integral (VTI) as well as PV systolic (S) and diastolic (D) velocities and their VTI were measured. RESULTS Regardless of the cardiac rhythm: 1) The MV-E velocity and E-VTI as well as PV-D velocity and D-VTI significantly decreased from expiration to inspiration; 2) the %E in PV-D velocity (27% in SR and 35% in AF) and D-VTI (38% in SR and 45% in AF) was significantly greater than that in MV-E velocity (18% in SR and 15% in AF) and E-VTI (21% in SR and 19% in AF), respectively; 3) the PV S/D and S/D-VTI significantly increased from expiration to inspiration. CONCLUSIONS A significant respiratory variation was observed in both MV and PV velocities in CP, not only in patients with SR but also in those with AF. Moreover, the %E was greater in the PV velocities than it was in the MV velocities. Evaluation of the %E in the PV velocities using TEE can be a sensitive diagnostic strategy for evaluation of patients with CP, even in patients with AF.
Collapse
|
62
|
Thomas JD. Patent foramen ovale with right-to-left shunting: echocardiographic alternatives. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY : THE JOURNAL OF THE WORKING GROUP ON ECHOCARDIOGRAPHY OF THE EUROPEAN SOCIETY OF CARDIOLOGY 2001; 2:74-5. [PMID: 11882431 DOI: 10.1053/euje.2001.0070] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
63
|
Marwick TH, Case C, Vasey C, Allen S, Short L, Thomas JD. Prediction of mortality by exercise echocardiography: a strategy for combination with the duke treadmill score. Circulation 2001; 103:2566-71. [PMID: 11382725 DOI: 10.1161/01.cir.103.21.2566] [Citation(s) in RCA: 118] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND In studies generally involving short follow-up, exercise echocardiography has been shown to predict composite end points. We sought to study the prediction of mortality with this test and to devise a strategy for combination with standard exercise testing. METHODS AND RESULTS Clinical, exercise testing, and echocardiographic data were collected in 5375 patients (aged 54+/-14 years, 3880 men) undergoing exercise echocardiography. The Duke treadmill score was derived from the results of treadmill exercise testing. Resting left ventricular (LV) function and the presence and severity of ischemia were interpreted by expert observers. Follow-up at 10.6 years (mean 5.5+/-1.9 years) was complete in 5211 patients (97%). The Duke score classified 59% of patients as low risk, 39% as intermediate risk, and 2% as high risk. Resting LV dysfunction was present in 1445 patients (27%), and the exercise echocardiogram was abnormal in 2525 patients (47%). Death occurred in 649 patients (12%). Over the first 6 years of follow-up, those with normal exercise echocardiograms had a mortality of 1% per year. Ischemia was an independent predictor of mortality. In sequential Cox models, the predictive power of clinical data was strengthened by adding the Duke score, resting LV function, and the results of exercise echocardiography. Exercise echocardiography was able to substratify patients with intermediate-risk Duke scores into groups with a yearly mortality of 2% to 7%. CONCLUSIONS A normal exercise echocardiogram confers a low risk of death, and positive results are an independent predictor of death; ischemia is incremental to other data. This test may be particularly useful in patients with intermediate-risk Duke treadmill scores.
Collapse
|
64
|
Riley EP, Thomas JD, Goodlett CR, Klintsova AY, Greenough WT, Hungund BL, Zhou F, Sari Y, Powrozek T, Li TK. Fetal alcohol effects: mechanisms and treatment. Alcohol Clin Exp Res 2001; 25:110S-116S. [PMID: 11391059 DOI: 10.1097/00000374-200105051-00020] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
This article represents the proceedings of a symposium at the 2000 ISBRA Meeting in Yokohama, Japan. The chair was Edward P. Riley. The presentations were (1) Does alcohol withdrawal contribute to fetal alcohol effects? by Jennifer D. Thomas and Edward P. Riley; (2) Brain damage and neuroplasticity in an animal model of binge alcohol exposure during the "third trimester equivalent," by Charles R. Goodlett, Anna Y. Klintsova, and William T. Greenough; (3) Ganglioside GM1 reduces fetal alcohol effects, by Basalingappa L. Hungund; and (4) Fetal alcohol exposure alters the wiring of serotonin system at mid-gestation, by F. Zhou, Y. Sari, Charles Goodlett, T. Powrozek, and Ting-Kai Li.
Collapse
|
65
|
Thomas JD, Fleming And SL, Riley EP. MK-801 can exacerbate or attenuate behavioral alterations associated with neonatal alcohol exposure in the rat, depending on the timing of administration. Alcohol Clin Exp Res 2001; 25:764-73. [PMID: 11371726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/16/2023]
Abstract
BACKGROUND We have reported that administration of MK-801, an NMDA receptor antagonist, during ethanol withdrawal in the developing rat attenuates ethanol's adverse effects on behavioral development. In the present study, we altered the timing of MK-801 delivery in relation to the last alcohol dose to determine if its protective effects were specific to the ethanol withdrawal phase. METHODS Five groups of rats were artificially reared and exposed to alcohol in a binge-like manner on postnatal day (PD) 6, producing peak blood alcohol levels of 335 mg/dl that cleared to 0 mg/dl by 33 hours. Four groups received MK-801 at various times after alcohol treatment (0, 9, 21, or 33 hr post-ethanol). The fifth alcohol-treated group received saline. Two artificially reared control groups were included: one was injected with saline and the other injected with 0.5 mg/kg MK-801. Finally, a normally reared suckle control group was also included. Activity level and performance on a spatial discrimination reversal-learning task were evaluated at PD 18 and PD 40, respectively. RESULTS Administration of MK-801 at the same time as ethanol treatment (0 hr) produced a high rate of mortality. Ethanol exposure on PD6 increased activity level relative to controls. Administration of MK-801 at 0 hr exacerbated this ethanol-induced overactivity, whereas administration of MK-801 at 21 and 33 hr reduced the severity of ethanol-related overactivity. Similarly, ethanol exposure on PD 6 significantly increased the number of errors committed on a spatial discrimination reversal-learning task. MK-801 injections 9 hrs after ethanol exacerbated this effect, whereas MK-801 treatment 33 hrs after ethanol attenuated this effect. Thus, MK-801 administration at the time of ethanol treatment was highly toxic, whereas during the withdrawal period it was protective. CONCLUSION These data are consistent with the hypothesis that ethanol exposure in the neonatal rat inhibits the NMDA receptor, producing a subsequent rebound in NMDA receptor activation and possible excitotoxicity during withdrawal. Both the acute inhibitory effects of ethanol and the excitatory effects of withdrawal may contribute to fetal alcohol effects.
Collapse
|
66
|
Lin SS, Lauer MS, Asher CR, Cosgrove DM, Blackstone E, Thomas JD, Garcia MJ. Prediction of coronary artery disease in patients undergoing operations for mitral valve degeneration. J Thorac Cardiovasc Surg 2001; 121:894-901. [PMID: 11326232 DOI: 10.1067/mtc.2001.112463] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVES We sought to develop and validate a model that estimates the risk of obstructive coronary artery disease in patients undergoing operations for mitral valve degeneration and to demonstrate its potential clinical utility. METHODS A total of 722 patients (67% men; age, 61 +/- 12 years) without a history of myocardial infarction, ischemic electrocardiographic changes, or angina who underwent routine coronary angiography before mitral valve prolapse operations between 1989 and 1996 were analyzed. A bootstrap-validated logistic regression model on the basis of clinical risk factors was developed to identify low-risk (< or =5%) patients. Obstructive coronary atherosclerosis was defined as 50% or more luminal narrowing in one or more major epicardial vessels, as determined by means of coronary angiography. RESULTS One hundred thirty-nine (19%) patients had obstructive coronary atherosclerosis. Independent predictors of coronary artery disease include age, male sex, hypertension, diabetes mellitus,and hyperlipidemia. Two hundred twenty patients were designated as low risk according to the logistic model. Of these patients, only 3 (1.3%) had single-vessel disease, and none had multivessel disease. The model showed good discrimination, with an area under the receiver-operating characteristic curve of 0.84. Cost analysis indicated that application of this model could safely eliminate 30% of coronary angiograms, corresponding to cost savings of $430,000 per 1000 patients without missing any case of high-risk coronary artery disease. CONCLUSION A model with standard clinical predictors can reliably estimate the prevalence of obstructive coronary atherosclerosis in patients undergoing mitral valve prolapse operations. This model can identify low-risk patients in whom routine preoperative angiography may be safely avoided.
Collapse
|
67
|
Firstenberg MS, Morehead AJ, Thomas JD, Smedira NG, Cosgrove DM, Marchand MA. Short-term hemodynamic performance of the mitral Carpentier-Edwards PERIMOUNT pericardial valve. Carpentier-Edwards PERIMOUNT Investigators. Ann Thorac Surg 2001; 71:S285-8. [PMID: 11388206 DOI: 10.1016/s0003-4975(01)02514-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Although long-term durability data exist, little data are available concerning the hemodynamic performance of the Carpentier-Edwards PERIMOUNT pericardial valve in the mitral position. METHODS Sixty-nine patients who were implanted with mitral PERIMOUNT valves at seven international centers between January 1996 and February 1997 consented to participate in a short-term echocardiography follow-up. Echocardiographs were collected at a mean of 600+/-133 days after implantation (range, 110 to 889 days); all underwent blinded core lab analysis. RESULTS At follow-up, peak gradients were 9.09+/-3.43 mm Hg (mean, 4.36+/-1.79 mm Hg) and varied inversely with valve size (p < 0.05). The effective orifice areas were 2.5+/-0.6 cm2 and tended to increase with valve size (p = 0.08). Trace mitral regurgitation (MR) was common (n = 48), 9 patients had mild MR, 1 had moderate MR, none had severe MR. All MR was central (n = 55) or indeterminate (n = 3). No paravalvular leaks were observed. Mitral regurgitation flow areas were 3.4+/-2.8 cm2 and were without significant volumes. CONCLUSIONS In this multicenter study, these mitral valves are associated with trace, although physiologically insignificant, central MR. Despite known echocardiographic limitations, the PERIMOUNT mitral valves exhibit similar hemodynamics to other prosthetic valves.
Collapse
|
68
|
Zuscik MJ, Chalothorn D, Hellard D, Deighan C, McGee A, Daly CJ, Waugh DJ, Ross SA, Gaivin RJ, Morehead AJ, Thomas JD, Plow EF, McGrath JC, Piascik MT, Perez DM. Hypotension, autonomic failure, and cardiac hypertrophy in transgenic mice overexpressing the alpha 1B-adrenergic receptor. J Biol Chem 2001; 276:13738-43. [PMID: 11278430 DOI: 10.1074/jbc.m008693200] [Citation(s) in RCA: 78] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
alpha(1)-Adrenergic receptors (alpha(1A), alpha(1B), and alpha(1D)) are regulators of systemic arterial blood pressure and blood flow. Whereas vasoconstrictory action of the alpha(1A) and alpha(1D) subtypes is thought to be mainly responsible for this activity, the role of the alpha(1B)-adrenergic receptor (alpha(1B)AR) in this process is controversial. We have generated transgenic mice that overexpress either wild type or constitutively active alpha(1B)ARs. Transgenic expression was under the control of the isogenic promoter, thus assuring appropriate developmental and tissue-specific expression. Cardiovascular phenotypes displayed by transgenic mice included myocardial hypertrophy and hypotension. Indicative of cardiac hypertrophy, transgenic mice displayed an increased heart to body weight ratio, which was confirmed by the echocardiographic finding of an increased thickness of the interventricular septum and posterior wall. Functional deficits included an increased isovolumetric relaxation time, a decreased heart rate, and cardiac output. Transgenic mice were hypotensive and exhibited a decreased pressor response. Vasoconstrictory regulation by alpha(1B)AR was absent as shown by the lack of phenylephrine-induced contractile differences between ex vivo mesenteric artery preparations. Plasma epinephrine, norepinephrine, and cortisol levels were also reduced in transgenic mice, suggesting a loss of sympathetic nerve activity. Reduced catecholamine levels together with basal hypotension, bradycardia, reproductive problems, and weight loss suggest autonomic failure, a phenotype that is consistent with the multiple system atrophy-like neurodegeneration that has been reported previously in these mice. These results also suggest that this receptor subtype is not involved in the classic vasoconstrictory action of alpha(1)ARs that is important in systemic regulation of blood pressure.
Collapse
MESH Headings
- Animals
- Blood Pressure/genetics
- Body Weight
- Bradycardia/genetics
- Cardiomegaly/genetics
- Dose-Response Relationship, Drug
- Echocardiography
- Epinephrine/blood
- Femoral Artery/pathology
- Heart Rate
- Heart Septum/pathology
- Humans
- Hydrocortisone/blood
- Hypotension/genetics
- Inositol 1,4,5-Trisphosphate/biosynthesis
- Kidney/metabolism
- Male
- Mice
- Mice, Knockout
- Mice, Transgenic
- Norepinephrine/blood
- Organ Culture Techniques
- Organ Size
- Phenotype
- Phenylephrine/blood
- Promoter Regions, Genetic
- Receptors, Adrenergic, alpha-1/biosynthesis
- Receptors, Adrenergic, alpha-1/genetics
- Time Factors
Collapse
|
69
|
Corsi C, Borsari M, Consegnati F, Sarti A, Lamberti C, Travaglini A, Shiota T, Thomas JD. Left ventricular endocardial surface detection based on real-time 3D echocardiographic data. EUROPEAN JOURNAL OF ULTRASOUND : OFFICIAL JOURNAL OF THE EUROPEAN FEDERATION OF SOCIETIES FOR ULTRASOUND IN MEDICINE AND BIOLOGY 2001; 13:41-51. [PMID: 11251256 DOI: 10.1016/s0929-8266(00)00123-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVE A new computerized semi-automatic method for left ventricular (LV) chamber segmentation is presented. METHODS The LV is imaged by real-time three-dimensional echocardiography (RT3DE). The surface detection model, based on level set techniques, is applied to RT3DE data for image analysis. The modified level set partial differential equation we use is solved by applying numerical methods for conservation laws. The initial conditions are manually established on some slices of the entire volume. The solution obtained for each slice is a contour line corresponding with the boundary between LV cavity and LV endocardium. RESULTS The mathematical model has been applied to sequences of frames of human hearts (volume range: 34-109 ml) imaged by 2D and reconstructed off-line and RT3DE data. Volume estimation obtained by this new semi-automatic method shows an excellent correlation with those obtained by manual tracing (r = 0.992). Dynamic change of LV volume during the cardiac cycle is also obtained. CONCLUSION The volume estimation method is accurate; edge based segmentation, image completion and volume reconstruction can be accomplished. The visualization technique also allows to navigate into the reconstructed volume and to display any section of the volume.
Collapse
|
70
|
Dewey CF, Thomas JD, Kunt M, Hunter IW. Prospects for telediagnosis using ultrasound. TELEMEDICINE JOURNAL : THE OFFICIAL JOURNAL OF THE AMERICAN TELEMEDICINE ASSOCIATION 2001; 2:87-100. [PMID: 10165360 DOI: 10.1089/tmj.1.1996.2.87] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Ultrasound imaging is currently used as a primary diagnostic tool in cardiology, abdominal disorders, pulmonary medicine, trauma, and obstetrics. Because of its relatively low capital and operating costs as well as its growth potential, it represents one of the major diagnostic modalities of future health care. However, the use of ultrasonography as a mobile and powerful modality is controlled by the availability of a highly skilled technician to acquire the images and an experienced physician to interpret them. This paper discusses the technology required to increase the availability of a diagnosing physician by employing telerobotics. With this technology, the physician can guide the motion of the transducer by the technician from a remote location. Thus, the physician controls the examination and renders the diagnosis. It is shown that communication lines at 1.5 Mbits/s (T-1 speed) can, with appropriate compression, support both real-time viewing of the ultrasound images and telerobotic manipulation of the transducer. The incremental costs of telediagnosis for an examination are estimated to be a small fraction of the base charges and significantly less than the expense of bringing a physician to a remote location or transporting a patient to a regional medical center. Telediagnosis can, in addition, provide benefits from immediate interpretation and consultation that cannot be duplicated using store-and-forward scenarios.
Collapse
|
71
|
Pu M, Prior DL, Fan X, Asher CR, Vasquez C, Griffin BP, Thomas JD. Calculation of mitral regurgitant orifice area with use of a simplified proximal convergence method: initial clinical application. J Am Soc Echocardiogr 2001; 14:180-5. [PMID: 11241013 DOI: 10.1067/mje.2001.110139] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
To validate a previously proposed simplified proximal flow convergence method for calculating mitral regurgitant orifice area (ROA), a prospective study was conducted in ambulatory patients and in patients undergoing open heart surgery. Assuming a pressure difference between the left ventricle and left atrium of approximately 100 mm Hg (jet velocity [v(p)] 500 cm/s) and setting the color aliasing velocity (v(a)) to 40 cm/s, we simplified the conventional proximal convergence method formula (ROA = 2pi(r2)v(a)/v(p)) to r2/2, where r is the radius of the proximal convergence isovelocity hemisphere. For 57 ambulatory patients with a wide range of mitral regurgitant severity (1 to 4+), ROA was calculated by the conventional (x) and simplified (y) methods, demonstrating excellent accuracy (r = 0.92; P <.001; DeltaROA [y - x] = 0.004 +/- 0.08 cm2). For 24 intraoperative patients, ROA calculated by the simplified formula (y) correlated well with the pulsed Doppler-thermodilution method (x) (r = 0.84; P <.01; DeltaROA [y - x] = -0.002 +/- 0.08cm2). This simplified proximal convergence formula yields an accurate assessment of ROA for a wide range of regurgitant severity, while the time required for this measurement is shortened by half (1.5 +/- 0.5 minutes versus 3.2 +/- 0.7 minutes). This may increase the frequency of calculating ROA in the clinical laboratory.
Collapse
|
72
|
Nakatani S, Firstenberg MS, Greenberg NL, Vandervoort PM, Smedira NG, McCarthy PM, Thomas JD. Mitral inertance in humans: critical factor in Doppler estimation of transvalvular pressure gradients. Am J Physiol Heart Circ Physiol 2001; 280:H1340-5. [PMID: 11179082 DOI: 10.1152/ajpheart.2001.280.3.h1340] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The pressure-velocity relationship across the normal mitral valve is approximated by the Bernoulli equation DeltaP = 1/2 rhoDeltav(2) + M. dv/dt, where DeltaP is the atrioventricular pressure difference, rho is blood density, v is transmitral flow velocity, and M is mitral inertance. Although M is indispensable in assessing transvalvular pressure differences from transmitral flow, this term is poorly understood. We measured intraoperative high-fidelity left atrial and ventricular pressures and simultaneous transmitral flow velocities by using transesophageal echocardiography in 100 beats (8 patients). We computed mean mitral inertance (M) by M = integral((DeltaP)-(1/2 x rho v(2))dt/integral(dv/dt)dt and we assessed the effect of the inertial term on the transmitral pressure-flow relation. ranged from 1.03 to 5.96 g/cm(2) (mean = 3.82 +/- 1.22 g/cm(2)). DeltaP calculated from the simplified Bernoulli equation (DeltaP = 1/2. rhov(2)) lagged behind (44 +/- 11 ms) and underestimated the actual peak pressures (2.3 +/- 1.1 mmHg). correlated with left ventricular systolic pressure (r = -0.68, P < 0.0001) and transmitral pressure gradients (r = 0.65, P < 0.0001). Because mitral inertance causes the velocity to lag significantly behind the actual pressure gradient, it needs to be considered when assessing diastolic filling and the pressure difference across normal mitral valves.
Collapse
|
73
|
Parker A, Meyer J, Lewitzky S, Rennich JS, Chan G, Thomas JD, Orho-Melander M, Lehtovirta M, Forsblom C, Hyrkkö A, Carlsson M, Lindgren C, Groop LC. A gene conferring susceptibility to type 2 diabetes in conjunction with obesity is located on chromosome 18p11. Diabetes 2001; 50:675-80. [PMID: 11246890 DOI: 10.2337/diabetes.50.3.675] [Citation(s) in RCA: 75] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Genome-wide nonparametric linkage analysis of 480 sib-pairs affected with type 2 diabetes revealed linkage to a previously unreported susceptibility locus on chromosome 18p11. This result improved with stringent subphenotyping using age- and sex-adjusted BMI, ultimately reaching a logarithm of odds of 3.82 (allele sharing 0.6654) at a point between markers D18S976 and D18S391 when the most obese 20% of the sample was analyzed. Several genes on chromosome 18 have been suggested as metabolic disease candidates, but none of these colocalize with our linkage result. We conclude that our results provide support for the presence of a currently uncharacterized gene on chromosome 18p, certain alleles of which confer increased susceptibility to type 2 diabetes in conjunction with obesity. We additionally observed moderate evidence for linkage to chromosome 1, near marker D1S3462; chromosome 4, near marker D4S2361; chromosome 5, near marker D5S1505; and chromosome 17, near marker D17S1301.
Collapse
|
74
|
Firstenberg MS, Thomas JD. Echocardiographic assessment of the normal mitral annular size. THE JOURNAL OF HEART VALVE DISEASE 2001; 10:143-5. [PMID: 11297198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
|
75
|
Garcia MJ, Thomas JD, Greenberg N, Sandelski J, Herrera C, Mudd C, Wicks J, Spencer K, Neumann A, Sankpal B, Soble J. Comparison of MPEG-1 digital videotape with digitized sVHS videotape for quantitative echocardiographic measurements. J Am Soc Echocardiogr 2001; 14:114-21. [PMID: 11174445 DOI: 10.1067/mje.2001.110270] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Digital format is rapidly emerging as a preferred method for displaying and retrieving echocardiographic studies. The qualitative diagnostic accuracy of Moving Pictures Experts Group (MPEG-1) compressed digital echocardiographic studies has been previously reported. The goals of the present study were to compare quantitative measurements derived from MPEG-1 recordings with the super-VHS (sVHS) videotape clinical standard. Six reviewers performed blinded measurements from still-frame images selected from 20 echocardiographic studies that were simultaneously acquired in sVHS and MPEG-1 formats. Measurements were obtainable in 1401 (95%) of 1486 MPEG-1 variables compared with 1356 (91%) of 1486 sVHS variables (P <.001). Excellent agreement existed between MPEG-1 and sVHS 2-dimensional linear measurements (r = 0.97; MPEG-1 = 0.95[sVHS] + 1.1 mm; P <.001; Delta = 9% +/- 10%), 2-dimensional area measurements (r = 0.89), color jet areas (r = 0.87, p <.001), and Doppler velocities (r = 0.92, p <.001). Interobserver variability was similar for both sVHS and MPEG-1 readings. Our results indicate that quantitative off-line measurements from MPEG-1 digitized echocardiographic studies are feasible and comparable to those obtained from sVHS.
Collapse
|