126
|
Hagendorff A, Klemm E, Bangard M, Dettmers C, Wolpert C, Schumacher B, Biersack HJ, Grünwald F, Lüderitz B, Pfeiffer D. Case report: regional cerebral hypoperfusion induced by ventricular tachycardia - short-term hippocampal hypoperfusion and its potential relationship to selective neuronal damage. J Interv Card Electrophysiol 2001; 5:435-41. [PMID: 11752912 DOI: 10.1023/a:1013202213276] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND Focussing on regional cerebral hypoperfusion during hemodynamically stable, but borderline hypotensive, sustained ventricular tachycardia (VT) experimental studies show (1) a reduction of cerebral blood flow (CBF) during tachyarrhythmias in contrast to the concept of CBF autoregulation, (2) a mediation of hypoperfusion by neuronal and humoral mechanisms, and (3) an involvment of microcirculation due to an ischemic stress response of the cerebral tissue. The clinical relevance of these observations remains still unclear. CASE REPORTS Two patients with coronary artery disease, left ventricular dysfunction and sustained monomorphic VT underwent electrophysiological study. VT was induced and the tracer (99m)Tc-HMPAO was injected after 3 minutes of ongoing VT. Regional CBF during this life threatening arrhythmia was determined with brain SPECT. A scanning protocol was performed after termination of VT. The measurements were repeated at baseline during normofrequent sinus rhythm (SR) one week later. CBF during SR was significantly reduced in the temporal lobe in comparison to the conditions during stable VT, particularly in the left hippocampus. CONCLUSION The reduction of hippocampal CBF due to cerebrovascular vasoconstriction and neuronal reflex mechanism previously observed in experiments during stable, sustained VT can be confirmed in a clinical scenario by high resolution (99m)Tc-HMPAO brain SPECT. This supports the hypothesis that repetitive stable VT can play a role in the pathophysiology of cerebrovascular insufficiency. Further clinical studies are needed to analyze the impact of tachyarrhythmias on cognitive and mnemic function.
Collapse
|
127
|
Butter C, Meisel E, Tebbenjohanns J, Engelmann L, Fleck E, Schubert B, Hahn S, Pfeiffer D. Transvenous biventricular defibrillation halves energy requirements in patients. Circulation 2001; 104:2533-8. [PMID: 11714646 DOI: 10.1161/hc4601.099463] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Defibrillation thresholds (DFT) with standard implantable cardioverter-defibrillator leads in the right ventricle (RV) may be determined by weak shock field intensity in the myocardium of the left ventricle (LV). Adding a shocking electrode in a coronary vein on the middle of the LV free wall, thereby establishing biventricular defibrillation, substantially reduced defibrillation requirements in animals. We investigated the feasibility of this approach in 24 patients receiving an implantable cardioverter-defibrillator using a prototype over-the-wire temporary LV defibrillation lead. METHODS AND RESULTS The LV lead was inserted through the coronary sinus, using a guide catheter and guidewire, into a posterior or lateral coronary vein whose location was determined by retrograde venography. Paired DFT testing compared a standard system (RV to superior vena cava plus can emulator [SVC+Can], 60% tilt biphasic shock) to a system including the LV lead. The biventricular system was tested with a dual-shock waveform (20% tilt monophasic shock from LV-->SVC+Can, then 60% tilt biphasic shock from RV-->SVC+Can). Twenty patients completed DFT testing. Venography and LV lead insertion time was 46+/-40 minutes. The biventricular system reduced mean DFT by 45% (8.9+/-1.1 J versus 4.9+/-0.5 J, P<0.001). Twelve patients (60%) had a standard system DFT >/=8 J, and the biventricular system gave a lower DFT in all patients. There were no adverse events related to the use of the LV lead, which was removed after testing. CONCLUSIONS Internal defibrillation using a transvenously inserted LV lead is feasible, produces significantly lower DFTs, and seems safe under the conditions tested. Biventricular defibrillation may be a useful option for reducing DFTs or could be added to an LV pacing lead for heart failure.
Collapse
|
128
|
Niehaus M, Schuchert A, Thamasett S, Pfeiffer D, Korte T, Pichlmaier M, Panning B, Belke R, Tebbenjohanns J. Multicenter experiences with a single lead electrode for dual chamber ICD systems. Pacing Clin Electrophysiol 2001; 24:1489-93. [PMID: 11707041 DOI: 10.1046/j.1460-9592.2001.01489.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Monitoring of atrial signals improves the accuracy in identifying supraventricular tachyarrhythmias to prevent inappropriate therapies in patients with implantable ICDs. Since difficulties due to the additional atrial lead were found in dual chamber ICD systems with two leads, the authors designed a single pass VDD lead for use with dual chamber ICDs. After a successful animal study, the prototype VDD lead (single coil defibrillation lead with two additional fractally coated rings for bipolar sensing in the atrium) was temporarily used in 30 patients during a German multicenter study. Atrial and ventricular signals were recorded during sinus rhythm (SR), atrial flutter, AF, and VT or VF. The implantation of the lead was successful in 27 of 30 patients. Mean atrial pacing threshold was 2.5 +/- 0.9 V/0.5 ms, mean atrial impedance was 213 +/- 31 ohms. Atrial amplitudes were greater during SR (2.7 +/- 1.6 mV) than during atrial flutter (1.46 +/- 0.3 mV, P < 0.05) or AF (0.93 +/- 0.37 mV, P < 0.01). During VF atrial "sinus" signals had significantly (P < 0.01) lower amplitudes (1.4 +/- 0.52 mV) than during SR. The mean ventricular sensing was 13.3 +/- 7.9 mV and mean ventricular impedance was 577 +/- 64 ohms. Defibrillation was successful with a 20-J shock in all patients. In addition, 99.6% of P waves could be detected in SR and 84.4% of flutter waves during atrial flutter. During AF, 56.6% of atrial signals could be detected without modification of the signal amplifier. In conclusion, a new designed VDD dual chamber lead provides stable detection of atrial and ventricular signals during SR and atrial flutter. Reliable detection of atrial signals is possible without modification of the ICD amplifier.
Collapse
|
129
|
Meisel E, Pfeiffer D, Engelmann L, Tebbenjohanns J, Schubert B, Hahn S, Fleck E, Butter C. Investigation of coronary venous anatomy by retrograde venography in patients with malignant ventricular tachycardia. Circulation 2001; 104:442-7. [PMID: 11468207 DOI: 10.1161/hc2901.093145] [Citation(s) in RCA: 106] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
BACKGROUND The coronary venous system is increasingly used for left ventricular or biventricular pacing in patients with severe heart failure. The present study investigated the structure of the coronary veins in patients presenting with structural heart disease and malignant ventricular tachyarrhythmias. The availability of veins for possible lead placement was assessed. METHODS AND RESULTS The number, relative size, and location of coronary veins were evaluated by retrograde venography in 129 patients undergoing cardioverter-defibrillator implantation. Detailed x-ray image analysis was performed in 86 patients, for whom optimal coronary sinus occlusion and vein visualization was achieved. The anterior interventricular vein and the middle cardiac vein were visible in 85 (99%) of 86 patients and in 86 (100%) of 86 patients, respectively. Between these 2 veins, at least 1 additional prominent vein was visible in 85 (99%) of 86 patients. Just 1 vein was present in 44 (51%) of 86 patients. Two veins were observed in 40 (46%) of 86 patients, and >2 veins were visualized in 2 (2%) of 86 patients. Venous anatomy allowed positioning of a 0.014-in guidewire in a coronary vein in 115 (93%) of 124 patients. CONCLUSIONS The presence, diameter, angulation, and tortuosity of veins as visualized by retrograde venography determine their acceptability for the placement of a lead in a predetermined location. Despite the considerable variability of the coronary venous system among patients, a lateral vessel for lead introduction was available in 82%, and a posterior or lateral vessel was available in 99% of individuals within a patient population that could potentially benefit from a lead on the left ventricle.
Collapse
|
130
|
Garnier Y, Pfeiffer D, Jensen A, Berger R. Effects of mild hypothermia on metabolic disturbances in fetal hippocampal slices after oxygen/glucose deprivation depend on depth and time delay of cooling. JOURNAL OF THE SOCIETY FOR GYNECOLOGIC INVESTIGATION 2001; 8:198-205. [PMID: 11525894 DOI: 10.1016/s1071-5576(01)00119-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
OBJECTIVE There is increasing evidence from animal experiments that mild hypothermia induced during or after cerebral ischemia might protect the immature brain from neuronal cell damage. However, the exact interrelation between the postischemic time delay and the degree of mild hypothermia by which to achieve neuroprotective effects on ischemic insults of different severity has not yet been elucidated systematically. To determine optimal neuroprotection, we studied the interaction between these variables in a recently modified hippocampal slice model. METHODS We investigated the recovery of energy metabolism and protein synthesis (PSR) in hippocampal slices from mature fetal guinea pigs after 20, 30, or 40 minutes of oxygen and glucose deprivation (OGD). Hypothermia of varying degrees was induced immediately or 2 or 4 hours after OGD and lasted for 12 hours. Prolonged inhibition of PSR after ischemia has been shown to be a sensitive marker of neuronal cell damage. RESULTS Hypothermia initiated immediately after OGD significantly improved the recovery of energy metabolism and PSR. If there was a 2-hour delay in the onset of hypothermia, neuroprotection depended on the degree of hypothermia. Reduction of the incubation temperature to 31C diminished the disturbances of energy metabolism and PSR, whereas lowering the bath temperature to only 34C was not effective. Hypothermia induced 4 hours after OGD did not have any influence on the recovery of energy metabolism and PSR. CONCLUSION We conclude that the effects of mild hypothermia on metabolic disturbances in hippocampal slices of mature fetal guinea pigs depended on the intervention delay and the degree of cooling. The shorter the postischemic intervention delay and the greater the degree of hypothermia, the better the neuroprotective effect seems to be.
Collapse
|
131
|
Berger R, Garnier Y, Löbbert T, Pfeiffer D, Jensen A. Circulatory responses to acute asphyxia are not affected by the glutamate antagonist lubeluzole in fetal sheep near term. JOURNAL OF THE SOCIETY FOR GYNECOLOGIC INVESTIGATION 2001; 8:143-8. [PMID: 11390248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/20/2023]
Abstract
OBJECTIVE Asphyxia is one of the main causes of perinatal brain damage that can result in psychomotor deficits during later development. Recently lubeluzole, a new glutamate antagonist, was shown to improve clinical outcome considerably without any safety concerns in adults who had acute ischemic stroke. However, our preliminary experiments showed transient alterations in heart rate as well as arterial hypertension after intravenous application of this compound in fetal sheep. The aim of the present study was to examine in detail whether lubeluzole affects circulatory responses to acute asphyxia in fetal sheep near term. METHODS Eleven fetal sheep were chronically instrumented at a mean gestational age of 133 +/- 2 days (term is at 147 days). The fetuses in the study group (n = 6) received three bolus injections of lubeluzole at 30-minute intervals (3 x 0.11 mg/kg estimated body weight), and five controls received solvent. Organ blood flows and physiologic variables were measured before, during, and after arrest of uterine blood flow for 2 minutes (ie, at 0, 1, 2, 3, 4, and 30 minutes). RESULTS Before asphyxia, distribution of combined ventricular output and physiologic variables in fetuses from the control group were in the normal range for chronically prepared fetal sheep near term. During acute asphyxia there was a redistribution of cardiac output toward the central organs accompanied by pronounced bradycardia and progressive increase in arterial blood pressure. There were nearly no differences between groups in the time course of physiologic and cardiovascular variables measured before, during, and after acute intrauterine asphyxia. CONCLUSION Lubeluzole did not affect circulatory responses to acute asphyxia in fetal sheep near term.
Collapse
|
132
|
Pfeiffer D, Rother T, Klein N, Mende M, Hagendorff A, Neugebauer A. [Catheter ablation of supraventricular tachyarrhythmias]. ZEITSCHRIFT FUR KARDIOLOGIE 2001; 89 Suppl 10:43-8; discussion 49-50. [PMID: 11151774 DOI: 10.1007/s003920070007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The term "supraventricular tachyarrhythmia" summarizes electrophysiologically different arrhythmias. After detection of the mechanism of the present arrhythmia, the weak part of the reentrant circuit has to be identified using different mapping techniques. The catheter ablation is widely used as focal ablation (sinus tachycardia, ectopic atrial tachycardia, focal atrial fibrillation) or for interruption of conducting pathways (accessory pathways, AV nodal reentrant tachycardia). A single ablation line should be created in isthmus-dependent atrial flutter or in incisional tachycardias, which is less used now-a-days. Multiple ablation lines are needed for ablation of atrial fibrillation, which is a method investigated in arrhythmia centers only. Some arrhythmias are less well understood, not localizable and therefore not curatively treated with ablation techniques. Newer three-dimensional mapping methods may help in this situation. The challenge at the present time is the catheter ablation of atrial fibrillation.
Collapse
|
133
|
Abstract
[figure: see text] 1,5- and 1,6-Dienes undergo a cyclization/boration reaction in the presence of a catalytic amount of Cp*2Sm.THF. The resulting organoboranes can be oxidized to the corresponding primary cyclic alcohols using standard conditions.
Collapse
|
134
|
Niehaus M, Thuermer G, Thamasett S, Pfeiffer D, Hoeper K, Korte T, Goerler H, Belke R, Tebbenjohanns J. [Usefulness of a VDD defibrillation electrode in recording atrial electrograms during atrial flutter and atrial fibrillation]. Herz 2001; 26:40-8. [PMID: 11258108 DOI: 10.1007/pl00002005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
BACKGROUND Monitoring of atrial signals improves the accuracy in identifying supraventricular tachyarrhythmias to prevent inappropriate therapies in patients with implantable cardioverter-defibrillators (ICD). Since complications due to the additional atrial lead were found in dual chamber ICD systems with 2 leads, we designed a single-pass VDD-lead for use with dual chamber ICDs. PATIENTS AND METHODS After promising animal experiments in a German multicenter study a prototype VDD lead (single-coil defibrillation electrode with 2 additional fractally coated rings for bipolar sensing in the atrium) was temporarily used in 20 patients. Atrial and ventricular signals were recorded during sinus rhythm, atrial flutter, atrial fibrillation and ventricular tachycardia or ventricular fibrillation. Terminations of ventricular arrhythmias were performed by internal DC shock. RESULTS The implantation of the electrode was successful in 18 of 20 patients. Mean atrial pacing threshold was 2.45 +/- 0.9 V/0.5 ms, mean atrial impedance was 215 +/- 31 Ohm. Atrial amplitudes were greater during sinus rhythm (2.7 +/- 1.6 mV) than during atrial flutter (1.36 +/- 0.28 mV, p < 0.05) or atrial fibrillation (0.92 +/- 0.29 mV, p < 0.01). During ventricular fibrillation atrial "sinus"-signals had significantly (p < 0.01) lower amplitudes than during sinus rhythm. Mean ventricular sensing was 13.3 +/- 7.9 mV, mean ventricular impedance was 577 +/- 64 Ohm. Defibrillation was successful with 20 J shock. 99.6% of P waves could be detected in sinus rhythm and 85 +/- 9.9% of flutter waves during atrial flutter. During atrial fibrillation 55% of atrial signals could be detected without modification of the signal amplifier. CONCLUSIONS A new designed VDD dual chamber electrode provides stable detection of atrial and ventricular signals during sinus rhythm and atrial flutter. For reliable detection of atrial fibrillation modifications of the signal amplifier are necessary.
Collapse
|
135
|
Seyfarth HJ, Siegemund A, Helling L, Woinke M, Pfeiffer D, Rühlmann C. [Recurrent coumarin necrosis in type II protein S deficiency]. VASA 2001; 30:72-5. [PMID: 11284095 DOI: 10.1024/0301-1526.30.1.72] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Coumarin necrosis is a rare but clinical very important complication of therapy with coumarin derivatives. We report a patient with congenital protein S deficiency type II, who developed coumarin necrosis during stabilization of phenprocoumon. Diagnostic problems and therapeutic alternatives are discussed considering the recent literature.
Collapse
|
136
|
Koksch M, Zeiger F, Wittig K, Siegemund A, Reininger CB, Pfeiffer D, Ruehlmann C. Coagulation, fibrinolysis and platelet P-selectin expression in peripheral vascular disease. Eur J Vasc Endovasc Surg 2001; 21:147-54. [PMID: 11237788 DOI: 10.1053/ejvs.2000.1294] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVES to examine coagulation, fibrinolysis, and platelet activity in patients with peripheral vascular disease (PVD). DESIGN fifty consecutive PVD patients and 50 healthy volunteers. (Prospective comparative study.) MATERIALS AND METHODS P-selectin expression in non-fixed, whole blood was measured flow cytometrically on non-stimulated and ADP- and TRAP-6-stimulated samples. Plasma fibrinogen, von Willebrand factor (vWF), tissue plasminogen activator (tPA), and plasminogen activator inhibitor-1 were determined using standard techniques. Disease severity was stratified on the basis of the ankle-brachial pressure index (ABPI) and the angiographic data were assessed using the Bollinger score. RESULTS coagulation and fibrinolysis parameters as well as the P-selectin expression on both stimulated and non-stimulated platelets were significantly increased in patients vs controls (all p<0.01). The respective sensitivity and specificity were as follows: P-selectin expression (81%, 94%), vWF (72%, 86%), fibrinogen (64%, 98%), PAI-1 (44%, 90%), tPA (15%, 100%). P-selectin expression on TRAP-6-stimulated MP correlated with disease severity (r=0.40, p<0.01). CONCLUSIONS these findings support the concept of ongoing thrombogenesis in the subclinical progression of PVD and demonstrate the high diagnostic sensitivity of flow cytometric analysis of platelet activation.
Collapse
|
137
|
Pfeiffer D. The paradox of changing the service delivery system in the field of rehabilitation. Disabil Rehabil 2001; 23:16-7. [PMID: 11213317 DOI: 10.1080/09638280150211239] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
138
|
Rose A, Scheller FW, Wollenberger U, Pfeiffer D. Quinoprotein glucose dehydrogenase modified thick-film electrodes for the amperometric detection of phenolic compounds in flow injection analysis. FRESENIUS' JOURNAL OF ANALYTICAL CHEMISTRY 2001; 369:145-52. [PMID: 11225357 DOI: 10.1007/s002160000633] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The use of thick-film electrodes as basic transducers for highly sensitive amperometric biosensors using PQQ (pyrroloquinoline quinone) dependent glucose dehydrogenase (GDH) with short response times is described. The enzyme is embedded in a polyurethane matrix on top of a platinum based thick film electrode and its ability to reduce oxidized phenolic compounds is exploited. The electrochemical amplification is based on the oxidation of the analyte on the surface of the electrode followed by its enzymatic reduction. Different parameters of the glucose dehydrogenase electrode system using dopamine as a model analyte were optimized, e.g., membrane thickness, pH value, buffer system, flow rate and storage conditions. Using optimized parameters the sensitivity and detection limits for various phenolic compounds were evaluated. The comparison of electrodes from the identical as well as from different batches shows the ability to produce a number of well reproducible sensors showing remarkably small differences with respect to parameters as sensitivity, response times and measuring range.
Collapse
|
139
|
Hagendorff A, Kölsch C, Dettmers C, Hartmann A, Pfeiffer D, Lüderitz B. [Is brain blood supply affected by changes in cardiac volume? Measurements of brain blood supply in healthy subjects during volume overload and in patients with artificial pacemaker by changing the pacing rate]. ZEITSCHRIFT FUR KARDIOLOGIE 2001; 90:35-42. [PMID: 11220085 DOI: 10.1007/s003920170210] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
A constant cerebral blood flow (CBF) in the presence of systemic blood pressure changes and cardiac output (CO) alterations during physiological conditions are postulated by the mechanism of cerebral autoregulation. The aim of the present study is the analysis of CBF in pacemaker (PM) patients with unspecific neurological symptoms. CBF was measured in 9 controls and 23 pacemaker patients with 133xenon, CO using Doppler echocardiography or impedance cardiography. Mean and individual CBF in controls remained unchanged when a CO increase of 28% induced by volume overload was observed. In PM patients a mean CO increase of 38% induced by an increase of basic pacing rate caused different effects of CBF. CBF increased or decreased by about 10% or remained constant. In summary, the data suggest an impairment of cerebrovascular function in those patients with concomittant CBF changes due to CO alterations (15/23 approximately equal to 65%). Thus, the analysis of brain perfusion in PM patients with unspecific neurological symptoms is possibly a new diagnostic feature in the future. It can be discussed whether or not indication and optimizing of pacemaker therapy has to be additionally analyzed by determination of endorgan perfusion.
Collapse
|
140
|
Schiemann U, Konturek JW, Osterhoff M, Assert R, Rembiasz K, Pfeiffer D, Schatz H, Domschke W, Pfeiffer A. Decreased expression of epidermal growth factor receptor and mRNA of its ligands in Helicobacter pylori-infected gastric mucosa. Scand J Gastroenterol 2001; 36:23-31. [PMID: 11218236 DOI: 10.1080/00365520150218020] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Epidermal growth factor (EGF) and TGF-alpha play a central role in maintaining gastric mucosal integrity. Little is known about the regulative role of the four other widely expressed epidermal growth factor receptor ligands, heparin-binding EGF, amphiregulin, betacellulin and cripto in the gastric mucosa. METHODS Nineteen patients with Helicobacter pylori-positive gastritis and 32 healthy controls were investigated. Mucosal mRNA expression of EGF receptor ligands was determined by quantitative PCR before and after H. pylori eradication. PCR products were analyzed by soft laser scanning densitometry. Moreover, the effect of chronic active gastritis on EGF receptor expression was assessed by [125I] EGF receptor autoradiography. Immunohistochemistry was performed for TGF-alpha to localize growth factor expression. RESULTS Antral and oxyntic biopsies showed strong mRNA expressions for TGF-alpha, amphiregulin and heparin binding EGF, but not for EGF, cripto and betacellulin. mRNA expression was significantly reduced down to 50% in H. pylori infection, significantly lower compared to normal gastric mucosa, and increased after eradication therapy. Moreover, chronic gastritis was associated with decreased antral EGF receptor binding compared to healthy controls, possibly reflecting reduced autoinduction. Immunohistochemical analyses localized TGF-alpha in the cytoplasma of gastric epithelial cells and revealed its increased expression after H. pylori eradication. CONCLUSIONS The data presented suggest that amphiregulin, heparin binding EGF and TGF-alpha are important EGF receptor ligands in the gastric mucosa. H. pylori infection apparently suppresses their mRNA as well as receptor expression that is reversed by H. pylori eradication. This deficiency of the gastroprotective EGF system may contribute to the gastric pathogenicity of H. pylori infection.
Collapse
|
141
|
Zeiger F, Stephan S, Hoheisel G, Pfeiffer D, Ruehlmann C, Koksch M. P-Selectin expression, platelet aggregates, and platelet-derived microparticle formation are increased in peripheral arterial disease. Blood Coagul Fibrinolysis 2000; 11:723-8. [PMID: 11132650 DOI: 10.1097/00001721-200012000-00005] [Citation(s) in RCA: 69] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Platelet volume has been reported to be increased in vascular disease. Therefore, we studied the relationship of mean platelet volume and platelet count as well as flow cytometrically measured platelet size and platelet function in 50 patients with peripheral arterial disease and 50 healthy volunteers. Platelet activation was measured by P-selectin expression analysis on resting and on stimulated platelets, and the determination of platelet aggregates and platelet-derived microparticles using flow cytometry. P-Selectin expression on platelets was significantly elevated in patients suffering from peripheral arterial disease (all P<0.0001). Platelet aggregates (P<0.0001) and platelet-derived microparticles (P<0.0001) were significantly higher in the patient group compared with controls, whereas mean platelet volume and platelet count showed no significant differences. Platelet count was inversely related to mean platelet volume in patients and controls (r = -0.43, P<0.001). The present study supports the hypothesis of platelet hyperreactivity and circulating activated platelets in peripheral arterial disease. Mean platelet volume, and platelet count cannot be used as predictive markers for platelet activation in peripheral arterial disease patients.
Collapse
|
142
|
Woinke M, Zeiger F, Ruehlmann C, Pfeiffer D, Koksch M. Changes in signal transduction in the platelets of patients with peripheral occlusive arterial disease. INT ANGIOL 2000; 19:345-50. [PMID: 11305734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
Abstract
BACKGROUND The finding that platelets of patients with peripheral occlusive arterial disease (POAD) circulate in an activated state prompted us to study platelet signal transduction. We hypothesised that platelet hyperreactivity is caused by changes in intracellular signalling. METHODS EXPERIMENTAL DESIGN a single blood sample was taken from the antecubital vein of each participant prior to the start of intravenous treatment with prostaglandins. SETTING patients were recruited from our inpatient Department of Cardiology and Angiology at the University Hospital. PARTICIPANTS 15 hospitalised patients with symptomatic POAD were randomly selected. Patients receiving antiplatelet drugs and those with diabetes were excluded. The control group consisted of 15 healthy volunteers from the medical staff. INTERVENTIONS blood tests were performed on the day of admission before any therapeutic intervention. MEASURES the platelet activation marker P-selectin was quantified on peripheral blood platelets before and after in vitro stimulation with platelet agonists (adenosine diphosphate, thrombin receptor activator peptide-6). The signal transduction cascade was also selectively blocked by preincubation with either: 1) forskolin, 2) phospholipase C inhibitor U-73122, or 3) bisindolylmaleimide. RESULTS A stronger inhibitory effect on ADP-stimulated platelets was seen in patients with U-73122, as indicated by a decrease in mean fluorescence intensity of 51% versus 34% in controls (p<0.0005). CONCLUSIONS Our findings support the assumption that changes in platelet signal transduction in POAD lead to platelet hyper-reactivity.
Collapse
|
143
|
Meisel E, Butter C, Philippon F, Higgins S, Strickberger SA, Smith J, Hahn S, Michel U, Schubert B, Pfeiffer D. Transvenous biventricular defibrillation. Am J Cardiol 2000; 86:76K-85K. [PMID: 11084104 DOI: 10.1016/s0002-9149(00)01295-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The recent success of biventricular pacing with transvenously implantable left ventricular leads suggests that left ventricular leads may be useful for other modes of therapy. Animal studies showed small leads inserted into a left ventricular vein dramatically reduced defibrillation strength requirements. This article describes a human investigation of the feasibility of biventricular defibrillation. Fifty-one patients undergoing implantable cardioverter defibrillator (ICD) implantation were enrolled. After insertion of a standard ICD lead, a prototype over-the-wire left ventricular defibrillation lead was inserted through the coronary sinus and into a vein on the left ventricle. Lead insertion was guided by retrograde venography. The left ventricular lead's location was randomized to the anterior or posterior vein. Randomized, paired defibrillation threshold (DFT) testing was performed to compare a standard ICD shock configuration (Control: right ventricle- --> superior vena cava+ + CAN+) to 1 of 3 biventricular shock configurations. In the anterior vein, the left ventricular lead was tested with either a single biphasic shock from right ventricle + left ventricle- --> superior vena cava+ + CAN+ or a dual biphasic shock. In the posterior vein, the left ventricular lead was tested with a dual biphasic shock. Dual shocks consisted of a 40% tilt biphasic shock from right ventricle- --> superior vena cava+ + CAN+ followed by another 40% tilt biphasic shock from left ventricle- --> superior vena cava+ + CAN+, delivered from a single 225 microF capacitance. Left ventricular lead positioning was successful in 41 of 46 patients (89%). Mean left ventricular lead insertion time was 17 +/- 17 minutes and 13 +/- 15 minutes for anterior and posterior locations, respectively. Mean DFTs were not statistically lower for the left ventricular shock configurations, but retrospective analysis showed a well-defined region of the posterolateral left ventricle where consistent DFT reduction was achieved with dual shocks (14.0 +/- 2.7 J vs 7.8 +/- 0.9 J; n = 5; p = 0.04). There were no adverse events requiring intervention due to the use of the left ventricular lead. Biventricular defibrillation is feasible and safe under the conditions used in this study. Additional studies are needed to verify whether dual shocks with posterolateral left ventricular lead positions consistently reduce DFTs.
Collapse
|
144
|
Berger R, Garnier Y, Pfeiffer D, Jensen A. Lipopolysaccharides do not alter metabolic disturbances in hippocampal slices of fetal guinea pigs after oxygen-glucose deprivation. Pediatr Res 2000; 48:531-5. [PMID: 11004246 DOI: 10.1203/00006450-200010000-00018] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The aim of the present study was to clarify whether endotoxins [lipopolysaccharides (LPS)] have a toxic effect on fetal brain tissue after cerebral ischemia, while excluding their effect on the cardiovascular system. Experiments were therefore performed on hippocampal slices prepared from mature fetal guinea pigs. In particular, we studied the influence of LPS on nitric oxide production, energy metabolism, and protein synthesis after oxygen-glucose deprivation (OGD). Incubating hippocampal slices in LPS (4 mg/L) for as long as 12 h did not alter cGMP tissue concentrations significantly. However, 10 min after OGD of 40-min duration, cGMP tissue concentrations were substantially increased in relation to controls, and this increase was almost completely blocked by the application of 100 microM N:(omega)-nitro-L-arginine, indicating that nitric oxide synthase was activated after OGD in fetal brain tissue. Again, LPS did not have any effect on cGMP tissue concentrations after OGD. Furthermore, addition of LPS altered neither protein synthesis nor energy metabolism measured 12 h after OGD. We therefore conclude that, apart from their well-known influence on the cardiovascular system, LPS do not alter metabolic disturbances in hippocampal slices of fetal guinea pigs 12 h after OGD. A direct toxic effect of LPS on immature brain tissue within this interval does not therefore seem to be very likely. However, delayed activation of LPS-sensitive pathways that may be involved in cell death, or damage limited to a small subgroup of cells such as oligodendrocyte progenitors, cannot be fully excluded.
Collapse
|
145
|
Abstract
The fifth generation of implantable cardioverter-defibrillators offer enhanced modes of detection of atrial and ventricular arrhythmias, antitachycardia pacing and shocks, multiprogrammability, intracardiac electrogram storage, and all functions of antibradycardia dual-chamber pacing including rate responsiveness and mode switching. There is no consensus on the indications for dual-chamber pacemaker defibrillator systems. This review focuses on the four major options of newer devices that might benefit patients: 1) permanent dual-chamber pacing in ischemic coronary disease patients, 2) detection and management of atrial fibrillation or other atrial tachyarrhythmias, 3) some newer indications for pacing, and 4) the suppression of inappropriate interventions. On the basis of published data, newer indications for the dual-chamber systems, advantages and limitations, and future perspectives are discussed.
Collapse
|
146
|
Pfeiffer D, Neugebauer A, Tebbenjohanns J, Schumacher B, Niehaus M, Rother T, Lüderitz B. Radiofrequency ablation of atrioventricular nodal reentrant tachycardia: mechanisms and recurrence rate. ZEITSCHRIFT FUR KARDIOLOGIE 2000; 89 Suppl 3:103-9. [PMID: 10810792 DOI: 10.1007/s003920070066] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Radiofrequency catheter ablation is the treatment of choice in atrioventricular nodal reentrant tachycardia. Electrophysiologic investigations in 623 patients revealed eight mechanisms of tachycardia ablation: Ablation of fast (I) or slow (II), modification of fast (III) or slow AV nodal pathways (IV), modification of both pathways (V), ablation of fast and modification of slow (VI), ablation of slow and modification of fast pathways (VII) and ablation of both pathways (VIII). The criteria of diagnosis of these eight mechanisms of tachycardia ablation are described. Follow-up showed fewer relapses in patients with ablation (0-2%) in comparison to patients with modification of a single AV nodal pathway (8-12%). Alteration of both pathways includes an increasing risk of total AV nodal block, which occurred in 7 patients (1.1%). Detailed analysis of the mechanism of catheter ablation is recommended in all patients after radiofrequency current delivery for AV nodal reentrant tachycardia to estimate the risk of relapse during follow-up or development of total AV block in the particular patient in case of a further ablation procedure.
Collapse
|
147
|
Greiner M, Pfeiffer D, Smith RD. Principles and practical application of the receiver-operating characteristic analysis for diagnostic tests. Prev Vet Med 2000; 45:23-41. [PMID: 10802332 DOI: 10.1016/s0167-5877(00)00115-x] [Citation(s) in RCA: 1268] [Impact Index Per Article: 52.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
We review the principles and practical application of receiver-operating characteristic (ROC) analysis for diagnostic tests. ROC analysis can be used for diagnostic tests with outcomes measured on ordinal, interval or ratio scales. The dependence of the diagnostic sensitivity and specificity on the selected cut-off value must be considered for a full test evaluation and for test comparison. All possible combinations of sensitivity and specificity that can be achieved by changing the test's cut-off value can be summarised using a single parameter; the area under the ROC curve. The ROC technique can also be used to optimise cut-off values with regard to a given prevalence in the target population and cost ratio of false-positive and false-negative results. However, plots of optimisation parameters against the selected cut-off value provide a more-direct method for cut-off selection. Candidates for such optimisation parameters are linear combinations of sensitivity and specificity (with weights selected to reflect the decision-making situation), odds ratio, chance-corrected measures of association (e. g. kappa) and likelihood ratios. We discuss some recent developments in ROC analysis, including meta-analysis of diagnostic tests, correlated ROC curves (paired-sample design) and chance- and prevalence-corrected ROC curves.
Collapse
|
148
|
Pfeiffer D, Heeg MJ, Winter CH. Synthesis and characterization of calcium complexes containing eta 2-pyrazolato ligands. Inorg Chem 2000; 39:2377-84. [PMID: 12526499 DOI: 10.1021/ic991049c] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Treatment of calcium bromide with 3,5-di-tert-butylpyrazolatopotassium (2 equiv) in tetrahydrofuran afforded Ca(tBu2pz)2(THF)2 (69%). The reaction of this compound with pyridine (3 equiv), tetramethylethylenediamine (TMEDA, 1 equiv), N,N,N',N',N"-pentamethyldiethylenetriamine (PMDETA, 1 equiv), triglyme (1 equiv), and tetraglyme (1 equiv) yielded Ca(tBu2pz)2(py)3 (51%), Ca(tBu2pz)2(TMEDA) (74%), Ca(tBu2pz)2(PMDETA) (50%), Ca(tBu2pz)2(triglyme) (73%), and Ca(tBu2pz)2(tetraglyme) (57%), respectively. Treatment of the tetrahydrofuran adduct of Ca(Me2pz)2, generated in situ, with PMDETA (1 equiv), triglyme (1 equiv), and tetraglyme (1 equiv) afforded Ca(Me2pz)2(PMDETA) (65%), Ca(Me2pz)2(triglyme) (54%), and Ca(Me2pz)2(tetraglyme) (40%), respectively. The X-ray crystal structures of Ca(tBu2pz)2(py)3, Ca(tBu2pz)2(TMEDA), Ca(tBu2pz)2(PMDETA), Ca(tBu2pz)2(triglyme), and Ca(Me2pz)2(PMDETA) revealed six-, seven-, or eight-coordinate calcium centers with eta 2-pyrazolato ligands. Ca(tBu2pz)2(triglyme) sublimes at 160 degrees C (0.1 mmHg). The potential utility of these complexes as source compounds for chemical vapor deposition processes is discussed.
Collapse
|
149
|
Klein N, Mende M, Hagendorff A, Neugebauer A, Pfeiffer D. [Alcohol concentration in the coronary sinus after transarterial ablation of septal hypertrophy in hypertrophic obstructive cardiomyopathy]. Dtsch Med Wochenschr 2000; 125:579-83. [PMID: 11320715 DOI: 10.1055/s-2007-1024364] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
BACKGROUND AND OBJECTIVE The size of the resulting myocardial necrosis varies after percutaneous transarterial ablation (PTA) of hypertrophied septum in patients with hypertrophic obstructive cardiomyopathy (HOCM). It was the aim of this study to discover whether the alcohol concentration in coronary sinus (CS) blood is a useful and appropriate parameter and what conclusions can be drawn from it. PATIENTS AND METHODS PTA was done in four patients (two women and two men, aged 30-53 years) with HOCM. Before the intervention the gradient across the left ventricular outflow tract ranged form 20 to 80 mmHg, postextrasystolic it ranged from 40 to 180 mmHg. 1 x 2 ml ethanol was injected into the first septal branch in 3 patients, 2 x 2 ml in one. The alcohol concentration in coronary sinus blood was measured every 30 sec for up to 5 min before and after ablation. The amounts were compared with the size of the akinetic area in the echocardiogram and the maximal value of creatine kinase, as a measure of the size of myocardial necrosis. RESULTS The left ventricular outflow gradient was reduced in all patients, to 0-30 mmHg and postextrasystolic to 30-90 mmHg. A pacemaker had to be implanted in one patient who developed a 3 degrees AV block. The alcohol concentration in coronary sinus blood ranged from maximally 1.53 and 0.23 per thousand after 30 sec and then fell to 0.56-0.12 per thousand after 5 min. The patient with the highest CS alcohol concentration also had the highest maximal value for creatine kinase (68 mumol/l) and the largest akinetic area in the echocardiogram. CONCLUSION The extent of myocardial necrosis can probably be estimated from the CS blood concentration of alcohol after alcohol ablation. If, after the first injection, high alcohol concentrations are measured, further alcohol injections are not indicated.
Collapse
|
150
|
Pfeiffer D, Luderitz B. The right atrial/transoesophagael approach for conversion of atrial fibrillation: a hybrid method for compromise? Eur Heart J 2000; 21:785-7. [PMID: 10781344 DOI: 10.1053/euhj.1999.2068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
|