Chang JD, Kim IS, Prabhakar S, Mansukhani SA, Lee SS, Yoo JH. Revision Total Hip Arthroplasty Using Imageless Navigation With the Concept of Combined Anteversion. J Arthroplasty 2017; 32:1576-1580. [PMID: 28139342 DOI: 10.1016/j.arth.2016.12.030] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Revised: 12/14/2016] [Accepted: 12/16/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of the study was to evaluate the implant positions and clinical results of revision total hip arthroplasty (THA) using an imageless navigation with the concept of combined anteversion. METHODS A total of 40 cementless revision THAs (24 men and 16 women) using an imageless navigation with the concept of combined anteversion were retrospectively evaluated. The concept of combined anteversion was applied in cup positioning based on Widmer's equation (cup anteversion + 0.7 × stem anteversion). The mean follow-up period was 80.7 months. Postoperatively, the inclination of the cup was evaluated on standard anteroposterior view of the radiograph, and the anteversion of the cup and femoral stem was evaluated using computed tomography scan. A cup inclination of 40° ± 10° and combined anteversion of the cup and femoral stem of 37° ± 10° based on Widmer's equation were regarded as the "safe zone." RESULTS The average anteversion of the revised femoral stems was 15.3° ± 2.9° (range, 9.5°-21.5°), whereas that of the remained femoral stems was 17.4° ± 9.7° (range, 4.2°-29.8°). The inclination, anteversion of the cup, and combined anteversion after revision THA were 42.3° ± 3.1° (range, 32.1°-48.2°), 25.0° ± 2.9° (range, 16.9°-29.5°), and 36.1° ± 3.4° (range, 27.2°-42.9°), respectively. Therefore, the position of the implants, relative to the safe zone, showed no outliers after the revision surgery. Neither dislocation nor osteolysis was observed after the surgery. CONCLUSION Favorable results of this study indicate that imageless navigation helps the surgeon in placing the components of revision THA in the safe zone. This study also shows that when this safe zone is consistently obtained, then no postoperative dislocations were observed in these patients over the 6-year follow-up period.
Collapse
Affiliation(s)
- Jun-Dong Chang
- Department of Orthopaedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong-si, Gyeonggi-do, Republic of Korea
| | - In-Sung Kim
- Department of Orthopaedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong-si, Gyeonggi-do, Republic of Korea
| | - Sharad Prabhakar
- Department of Orthopaedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong-si, Gyeonggi-do, Republic of Korea
| | - Sameer A Mansukhani
- Department of Orthopaedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong-si, Gyeonggi-do, Republic of Korea
| | - Sang-Soo Lee
- Department of Orthopaedic Surgery, Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon, Republic of Korea
| | - Je-Hyun Yoo
- Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, Republic of Korea
| |
Collapse
|
452
|
Goyal P, Lau A, McCalden R, Teeter MG, Howard JL, Lanting BA. Accuracy of the modified Hardinge approach in acetabular positioning. Can J Surg 2017; 59:247-53. [PMID: 27240130 DOI: 10.1503/cjs.011415] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND The surgical approach chosen for total hip arthroplasty (THA) may affect the positioning of the acetabular component. The purpose of this study was to examine the accuracy in orienting the acetabular component using the modified Hardinge approach. METHODS We used our institutional arthroplasty database to identify patients with primary, press-fit, hemispherical acetabular components of a metal-on-polyethylene THA performed between 2003 and 2011. Patients with radiographs obtained 1-3 years after the index procedure were included for measurement of anteversion and inclination angles. Acceptable values of anteversion and abduction angles were defined as 15° ± 10° and 40° ± 10°, respectively. RESULTS We identified 1241 patients from the database, and the modified Hardinge approach was used in 1010 of the patients included in our analysis. The acetabular component was anteverted in the acceptable zone in 54.1% of patients. The abduction angle was within the defined range in 79.2% of patients. Combined anteversion and abduction angles within the defined zone were present in 43.6% of patients. CONCLUSION Consistent with studies examining accuracy from other approaches, our study reveals that the modified Hardinge approach was only moderately accurate in positioning the acetabular component in the acceptable zone.
Collapse
Affiliation(s)
- Prateek Goyal
- From the Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON (Goyal, McCalden, Teeter, Lau, Howard, Lanting); the Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON (Teeter)l; and the Surgical Innovation Program, Lawson Health Research Institute, London, ON (Teeter)
| | - Adrian Lau
- From the Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON (Goyal, McCalden, Teeter, Lau, Howard, Lanting); the Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON (Teeter)l; and the Surgical Innovation Program, Lawson Health Research Institute, London, ON (Teeter)
| | - Richard McCalden
- From the Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON (Goyal, McCalden, Teeter, Lau, Howard, Lanting); the Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON (Teeter)l; and the Surgical Innovation Program, Lawson Health Research Institute, London, ON (Teeter)
| | - Matthew G Teeter
- From the Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON (Goyal, McCalden, Teeter, Lau, Howard, Lanting); the Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON (Teeter)l; and the Surgical Innovation Program, Lawson Health Research Institute, London, ON (Teeter)
| | - James L Howard
- From the Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON (Goyal, McCalden, Teeter, Lau, Howard, Lanting); the Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON (Teeter)l; and the Surgical Innovation Program, Lawson Health Research Institute, London, ON (Teeter)
| | - Brent A Lanting
- From the Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON (Goyal, McCalden, Teeter, Lau, Howard, Lanting); the Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON (Teeter)l; and the Surgical Innovation Program, Lawson Health Research Institute, London, ON (Teeter)
| |
Collapse
|
453
|
Yan Y, Chen H, Feng J, Chen K, Zhou K, Hong W, Wang Y, Liu Z, Zhang J, Yang Q, Guo L, He C. Poor performance of Enduron polyethylene liner in total hip arthroplasty: a minimum ten-year follow up and ultra-morphological analysis of wear particles. INTERNATIONAL ORTHOPAEDICS 2017; 41:723-730. [PMID: 27178441 DOI: 10.1007/s00264-016-3217-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2016] [Accepted: 04/25/2016] [Indexed: 11/29/2022]
Abstract
PURPOSE The aim of the present study was to investigate the long-term outcome and the wear characteristics of two distinct types of ultra-high molecular weight polyethylene (UHMWPE) liners in total hip arthroplasty (THA). METHODS We conducted a retrospective clinical study on patients which were treated with total hip arthroplasty using either Enduron polyethylene (Enduron PE) or Trilogy polyethylene (Trilogy PE) liners based on a minimum of ten year follow up data. Morphological analyses of wear particles from tissue samples, which were harvested during revision surgeries, were also performed. RESULTS A total of 79 THAs in the Enduron group and 55 THAs in the Trilogy group were available for analysis. Kaplan-Meier survival with revision for wear-related complications as the endpoint of the Enduron PE liners was lower than that of Trilogy PE liners at ten years (93.5 % and 100 %, P = 0.03). The Enduron group had higher mean linear wear rate than that of the Trilogy group (0.20 ± 0.09 and 0.09 ± 0.03 mm/year, P < 0.01). The incidence of osteolysis for the Enduron group was higher than that of the Trilogy group (33.3 % and 12 %, P = 0.04). Under transmission electron microscopy, the Enduron group had more than 82 % of the particles less than 1.0 μm in size and more than 57 % of the particles less than 0.5 μm. CONCLUSION The long-term performance of Enduron liners was worse than that of Trilogy liners. Further clinical follow-up may be necessary in patients with Enduron PE liners in order to avoid catastrophic complications.
Collapse
Affiliation(s)
- Yufei Yan
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Hao Chen
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Jianmin Feng
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Kaizhe Chen
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Kaidi Zhou
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Weixiang Hong
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Yi Wang
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Zhihong Liu
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Jiong Zhang
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Qingming Yang
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Lei Guo
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China.
- Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, China.
| | - Chuan He
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China.
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China.
| |
Collapse
|
454
|
Imai H, Miyawaki J, Kamada T, Maruishi A, Takeba J, Miura H. Preoperative Planning and Operative Techniques of the Shorter Tapered Stem Compared to the Metaphyseal Fit Stem in Cementless Total Hip Arthroplasty. J Arthroplasty 2017; 32:1192-1199. [PMID: 27913129 DOI: 10.1016/j.arth.2016.11.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2016] [Revised: 10/12/2016] [Accepted: 11/01/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND In order to prevent postoperative dislocation due to prosthetic impingement as a result of total hip arthroplasty (THA), the combined anteversion (CA) theory, which combines the anteversion of the femoral stem and the acetabular socket, has been revised in recent years. Particularly, it is necessary to keep CA within the target zone. METHODS The aim of this study was to investigate whether postoperative CA can be kept within the target zone while using the operative technique which prepares the socket first in cementless THA, by estimating the anteversion of the metaphyseal fit stem or the shorter, tapered wedge stem using preoperative 3-dimensional computerized planning, and by adjusting the anteversion of the socket using a navigation system that considers CA. One hundred fourteen patients (118 hips) were recruited for the study. RESULTS Postoperative CA in THA using the metaphyseal fit stem was kept within the target zone for 56 of the 60 hips (93.3%). Using the shorter, tapered wedge stem, 49 of the 58 hips (84.4%) were within the target zone. No postoperative dislocations were observed in any hips. CONCLUSION We found that the metaphyseal fit stem worked better than the shorter, tapered wedge stem in terms of meeting the planned CA. The shorter, tapered wedge stems were flexible in rotation according to the anatomical configuration of the proximal femur. Therefore, the stem could be placed second with the metaphyseal fit stem, but we recommend placing the stem first with the shorter, tapered wedge stem.
Collapse
Affiliation(s)
- Hiroshi Imai
- Department of Bone and Joint Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| | - Joji Miyawaki
- Department of Bone and Joint Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| | - Tomomi Kamada
- Department of Bone and Joint Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| | - Akira Maruishi
- Department of Bone and Joint Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| | - Jun Takeba
- Department of Bone and Joint Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| | - Hiromasa Miura
- Department of Bone and Joint Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| |
Collapse
|
455
|
Nam D, Riegler V, Clohisy JC, Nunley RM, Barrack RL. The Impact of Total Hip Arthroplasty on Pelvic Motion and Functional Component Position is Highly Variable. J Arthroplasty 2017; 32:1200-1205. [PMID: 27919581 DOI: 10.1016/j.arth.2016.11.008] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Revised: 11/07/2016] [Accepted: 11/08/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND This study's purpose was to determine the impact of THA implantation on pelvic motion, and to assess motion in patients with a history of lumbar fusion or prosthetic dislocation. METHODS This was an IRB-approved, prospective investigation of 3 cohorts: (1) patients without a history of lumbar surgery undergoing THA (group A), (2) patients with a lumbar fusion (group B), and (3) patients with a THA prosthetic dislocation (group C). All patients received both standing and sitting lateral pelvis images to measure sacral slope and pelvic tilt in the sagittal plane. RESULTS Fifty-eight patients were enrolled (24 group A, 27 group B, and 7 group C), with no differences in age, gender, or body mass index (P = .1-.7). In group A, the mean change in sacral slope from standing to sitting was 22.1° ± 15.2° preoperatively and 19.5° ± 14.8° postoperatively. However, in 13 patients, the difference in pelvic motion from the standing to seated position, from preoperatively to postoperatively, was >5° and in 10 patients, this difference was >10°. The change in standing to sitting sacral slope was significantly less in patients with a lumbar fusion (9.8° ± 8.2°) and history of prosthetic dislocation (12.5° ± 4.7°) vs group A (P < .001 and P = .008). CONCLUSION Implantation of a THA can increase or decrease sagittal plane pelvic motion from the standing to seated position with a high degree of variability. Thus, the ability to predict ideal component positioning from preoperative images may be challenging.
Collapse
Affiliation(s)
- Denis Nam
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Venessa Riegler
- Department of Orthopedic Surgery, Washington University School of Medicine/Barnes-Jewish Hospital, St. Louis, Missouri
| | - John C Clohisy
- Department of Orthopedic Surgery, Washington University School of Medicine/Barnes-Jewish Hospital, St. Louis, Missouri
| | - Ryan M Nunley
- Department of Orthopedic Surgery, Washington University School of Medicine/Barnes-Jewish Hospital, St. Louis, Missouri
| | - Robert L Barrack
- Department of Orthopedic Surgery, Washington University School of Medicine/Barnes-Jewish Hospital, St. Louis, Missouri
| |
Collapse
|
456
|
Boettner F, Zingg M, Emara AK, Waldstein W, Faschingbauer M, Kasparek MF. The Accuracy of Acetabular Component Position Using a Novel Method to Determine Anteversion. J Arthroplasty 2017; 32:1180-1185. [PMID: 27839959 DOI: 10.1016/j.arth.2016.10.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Revised: 09/19/2016] [Accepted: 10/03/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND This study compares the differences in acetabular component position, leg length discrepancy, and hip offset between the anterior and posterior approach. A novel method is applied to determine the acetabular anteversion using the C-arm tilt angle for the anterior approach. METHODS Hundred consecutive anterior total hip arthroplasties were matched according to gender, body mass index, and age to a cohort of 100 primary total hip arthroplasties operated on through a posterior approach. Postoperative radiographs were analyzed to determine cup inclination, cup anteversion, leg length discrepancy, and hip offset. RESULTS The mean inclination was 40.8° (range 33°-48°) and 45.1° (range 33°-55°) for the anterior and posterior approach, respectively. Using the new C-arm tilt plane technique, an average acetabular anteversion of 18.4° (range 11°-26°) was achieved with the anterior approach compared with 23.6° (range 8°-38°) with the posterior approach. Hundred percent cups in the anterior group and 81% in the posterior group fell within the safe zone (P < .001). There was no difference in the overall hip offset between the operated side and the contralateral side for the anterior (P = .074) and posterior (P = .919) group. There was no difference in leg length discrepancy between the 2 approaches (P = .259). CONCLUSION Intraoperative fluoroscopy-assisted direct anterior approach was associated with improved acetabular component positioning. However, no benefit was shown with regards to restoration of hip offset or leg length.
Collapse
Affiliation(s)
- Friedrich Boettner
- Adult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, New York, New York
| | - Matthieu Zingg
- Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, Genève 14, Switzerland
| | - Ahmed K Emara
- Adult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, New York, New York
| | - Wenzel Waldstein
- Department of Orthopedics, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | | | - Maximilian F Kasparek
- Adult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, New York, New York
| |
Collapse
|
457
|
A retrospective analysis of the merits and challenges associated with simultaneous bilateral THA using the direct anterior approach. Hip Int 2017; 27:169-174. [PMID: 27886354 DOI: 10.5301/hipint.5000449] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/22/2016] [Indexed: 02/04/2023]
Abstract
INTRODUCTION 15%-20% of patients presenting for total hip arthroplasty (THA) have bilateral disease. While simultaneous bilateral THA is of interest to patients and surgeons, debate persists regarding its merits. The majority of previous reports on simultaneous bilateral THA involve patients in the lateral decubitus position, which require repositioning, prepping and draping, and exposure of a fresh wound to pressure and manipulation for the contralateral THA. The purpose of this study was to compare complications, component position, and financial parameters for simultaneous versus staged bilateral THAs using the direct anterior approach (DAA). METHODS Medical records were reviewed for patient demographics, medical history, operative time, estimated blood loss (EBL), change in hemoglobin, transfusion, tranexamic acid (TXA) use, length of stay (LOS), discharge disposition, leg length discrepancy, acetabular cup position, and perioperative complications. Cost and reimbursement data were analysed. RESULTS 44 patients were included in the sequential group and fifteen patients in the simultaneous group. Operative time, EBL, hemoglobin drop, transfusion rate, and LOS were significantly increased for simultaneous group. There was no significant difference in component position, complications, or readmissions between groups. Profit per hip was significantly higher for the simultaneous group. DISCUSSION While simultaneous DAA THA presents challenges, our results suggest that simultaneous DAA THA may add value to the healthcare system without resulting in increased complications compared to sequential hip arthroplasty.
Collapse
|
458
|
Inoue D, Kabata T, Kajino Y, Taga T, Hasegawa K, Yamamoto T, Takagi T, Ohmori T, Tsuchiya H. The influence of surgical approach on postoperative pelvic tilt after total hip arthroplasty. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2017; 27:1131-1138. [DOI: 10.1007/s00590-017-1946-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2016] [Accepted: 03/11/2017] [Indexed: 12/29/2022]
|
459
|
Abstract
Navigation in primary total hip arthroplasty has a history of over 20 years. During this process, imageless computer navigation can be particularly helpful in optimally restoring the hip’s biomechanics. This involves the accurate placement of the acetabular component with the determination of the anteversion and abduction, whereby the navigated femur-first technique also allows for a calculation of the combined anteversion. Additional critical parameters such as the reconstruction of the rotation centre, as well as the femoral and acetabular offset, can also be optimally adjusted. Last but not least, an intra-operative evaluation and equalisation of the leg length is possible. Nonetheless, the disadvantages of this surgical technique in terms of the high costs in the acquisition and preservation of the necessary devices, as well as the longer operation time, must be taken into account. However, economic aspects are not the only thing preventing widespread use of the navigation technique. Determining the plane of reference (APP) for the optimal orientation of the implants is based on palpation of the bony landmarks – and this is influenced by the thickness of the soft tissue layer. Furthermore, the experience of the surgeon constitutes a variable that influences the accuracy of navigation. In summary, hip navigation certainly offers an interesting technique for the optimisation of total hip arthroplasty with reconstruction of proper biomechanics. At the same time, there is currently a lack of high-quality randomised controlled long-term trials that evaluate the clinical advantage for the patients, together with cost utility and survival rates.
Cite this article: Renner L, Janz V, Perka C, Wassilew GI. What do we get from navigation in primary THA? EFORT Open Rev 2016;1:205-210. 10.1302/2058-5241.1.000034.
Collapse
Affiliation(s)
- Lisa Renner
- Centre for Musculoskeletal Surgery, Charité Universitätsmedizin, Berlin, Germany
| | - Viktor Janz
- Centre for Musculoskeletal Surgery, Charité Universitätsmedizin, Berlin, Germany
| | - Carsten Perka
- Centre for Musculoskeletal Surgery, Charité Universitätsmedizin, Berlin, Germany
| | - Georgi I Wassilew
- Centre for Musculoskeletal Surgery, Charité Universitätsmedizin, Berlin, Germany
| |
Collapse
|
460
|
Chang JD, Kim IS, Bhardwaj AM, Badami RN. The Evolution of Computer-Assisted Total Hip Arthroplasty and Relevant Applications. Hip Pelvis 2017; 29:1-14. [PMID: 28316957 PMCID: PMC5352720 DOI: 10.5371/hp.2017.29.1.1] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 01/31/2017] [Accepted: 02/09/2017] [Indexed: 12/27/2022] Open
Abstract
In total hip arthroplasty (THA), the accurate positioning of implants is the key to achieve a good clinical outcome. Computer-assisted orthopaedic surgery (CAOS) has been developed for more accurate positioning of implants during the THA. There are passive, semi-active, and active systems in CAOS for THA. Navigation is a passive system that only provides information and guidance to the surgeon. There are 3 types of navigation: imageless navigation, computed tomography (CT)-based navigation, and fluoroscopy-based navigation. In imageless navigation system, a new method of registration without the need to register the anterior pelvic plane was introduced. CT-based navigation can be efficiently used for pelvic plane reference, the functional pelvic plane in supine which adjusts anterior pelvic plane sagittal tilt for targeting the cup orientation. Robot-assisted system can be either active or semi-active. The active robotic system performs the preparation for implant positioning as programmed preoperatively. It has been used for only femoral implant cavity preparation. Recently, program for cup positioning was additionally developed. Alternatively, for ease of surgeon acceptance, semi-active robot systems are developed. It was initially applied only for cup positioning. However, with the development of enhanced femoral workflows, this system can now be used to position both cup and stem. Though there have been substantial advancements in computer-assisted THA, its use can still be controversial at present due to the steep learning curve, intraoperative technical issues, high cost and etc. However, in the future, CAOS will certainly enable the surgeon to operate more accurately and lead to improved outcomes in THA as the technology continues to evolve rapidly.
Collapse
Affiliation(s)
- Jun-Dong Chang
- Arthroplasty Center, Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea
| | - In-Sung Kim
- Arthroplasty Center, Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea
| | - Atul M Bhardwaj
- Arthroplasty Center, Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea
| | - Ramachandra N Badami
- Arthroplasty Center, Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea
| |
Collapse
|
461
|
Kaku N, Tabata T, Tagomori H, Tsumura H. Isolated acetabular revision with femoral stem retention after bipolar hip arthroplasty. Arch Orthop Trauma Surg 2017; 137:425-430. [PMID: 28150224 DOI: 10.1007/s00402-017-2633-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Indexed: 12/01/2022]
Abstract
INTRODUCTION In bipolar hemiarthroplasty, migration of the outer cup component into the acetabular cup, with evidence of severe osteolysis in the acetabulum, commonly occurs without loosening of the femoral component. The merits of retaining the stable femoral component in these cases have been debated. Our study aimed to determine whether revision of the acetabular component in isolation could be successfully performed. MATERIALS AND METHODS The data of 54 patients (61 hips), 44 women, and 10 men, aged 67.7 (range 47-86) years at the time of the index revision, were analyzed. The average time from primary operation to revision surgery was 14.9 (range 1.0-27.0) years, with an average follow-up time after revision of 5.2 (range, 1.0-18.7) years. Indications for acetabular revision included migration of the outer cup component (N = 55), disassembly of the bipolar cup (N = 4), and recurrent dislocation (N = 2). Fixation of the femoral stem was cementless in 49 hips and cemented in 12. Bone grafting for osteolysis of the proximal femur around the stem was performed in six hips. An acetabular reinforcement ring with a cemented cup was used in 31 hips, with cementless cup fixation in 29 hips, and cemented cup in one case. RESULTS On average, the Harris hip score improved from 57.0 ± 21.6 to 87.4 ± 6.40 points after revision. Two cases of femoral periprosthetic fracture were treated with osteosynthesis 3 year post-revision. There was no evidence of loosening of the femoral stem or subsidence, with a non-progressive radiolucent line <2 mm identified in one case. There was no incidence of dislocation or deep infection, and all components were judged to be stable at the final follow-up. CONCLUSION Isolated acetabular revision can be reliably performed in cases of failed bipolar hemiarthroplasty with a well-fixed femoral component.
Collapse
Affiliation(s)
- Nobuhiro Kaku
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, 1-1 Idaigaoka, Hasama-machi Yufu city, Oita, 879-5593, Japan.
| | - Tomonori Tabata
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, 1-1 Idaigaoka, Hasama-machi Yufu city, Oita, 879-5593, Japan
| | - Hiroaki Tagomori
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, 1-1 Idaigaoka, Hasama-machi Yufu city, Oita, 879-5593, Japan
| | - Hiroshi Tsumura
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, 1-1 Idaigaoka, Hasama-machi Yufu city, Oita, 879-5593, Japan
| |
Collapse
|
462
|
Goyal P, Lau A, Naudie DD, Teeter MG, Lanting BA, Howard JL. Effect of Acetabular Component Positioning on Functional Outcomes in Primary Total Hip Arthroplasty. J Arthroplasty 2017; 32:843-848. [PMID: 27965176 DOI: 10.1016/j.arth.2016.08.024] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Revised: 08/04/2016] [Accepted: 08/18/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Acetabular component positioning is crucial to a successful total hip arthroplasty (THA). This study evaluated the effect of absolute acetabular component position as well as acetabular position relative to bony anatomy on patient-reported functional outcomes after primary THA. METHODS Primary, press fit, hemispherical metal-on-polyethylene THA performed between 2003 and 2011 were analyzed. Western Ontario and McMaster Osteoarthritis Index (WOMAC), Harris Hip Score (HHS), Short Form-12 scores, and radiographs between 2 and 3 years after the index procedure were assessed. RESULTS Of the 1241 primary THA included, the mean abduction and anteversion angles were 44.4 ± 6.94 and 21.7 ± 11.9 degrees, respectively. The mean anterior and lateral overhang were 1.9 ± 3.6 and 2.5 ± 3.4 mm, respectively. There was no correlation between functional outcomes and acetabular inclination. A weak positive correlation between anteversion and HHS (P < .001) and WOMAC (P = .02) scores was found. For relative position, anterior overhang of the acetabular component beyond the bone resulted in inferior Short Form-12 physical function (P = .001), HHS (P = .004), and WOMAC (P < .001) scores compared to those with bony coverage. Mean HHS pain score was 41.20 ± 5.69 in patients with lateral overhang and 41.97 ± 5.04 in those who had bony coverage of the lateral edge of the acetabular component (P = .02). CONCLUSION The tribology and biomechanics of acetabular component position have been extensively studied without examination of how it affects patient function. Although statistical significance was seen, clinical outcome scores were not sensitive enough to show a clinically significant effect of the absolute or relative position of the acetabular component.
Collapse
Affiliation(s)
- Prateek Goyal
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
| | - Adrian Lau
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
| | - Douglas D Naudie
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
| | - Matthew G Teeter
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada; Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada; Surgical Innovation Program, Lawson Health Research Institute, London, ON, Canada
| | - Brent A Lanting
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
| | - James L Howard
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
| |
Collapse
|
463
|
A Validated Single-View Radiographic Alternative to Computed Tomography for the Measurement of Femoral Anteversion: A Method-Comparison Study. J Arthroplasty 2017; 32:1018-1023. [PMID: 27816368 DOI: 10.1016/j.arth.2016.09.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2016] [Revised: 08/15/2016] [Accepted: 09/09/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Although preoperative templating in total hip arthroplasty is helpful to ensure appropriate component position, there is no single-view radiographic method to determine femoral anteversion (FA) preoperatively. The aim of the present study was to validate the use of radiographic measurement of FA using a modified Budin view. METHODS This prospective study reports on 105 limbs from 65 patients. Computed tomography (CT) scans and radiographs were obtained to measure native FA. Radiographs were obtained using the modified Budin protocol with 90° flexion at the knee and 90° flexion and 30° abduction at the hip. Pearson correlation analyses, paired-samples t-test, and Bland-Altman plots were performed to assess correlation and agreement between methods. Data were grouped into subsets based on CT-derived FA in 5° intervals. Groups included all limbs, FA < 35°, FA < 30°, and FA < 25°. RESULTS For all limbs, Bland-Altman analysis revealed a fixed bias (mean bias, -0.8°; 95% confidence interval, -1.4° to -0.2°) and showed that radiographic methods underestimated FA. Subset analyses were performed and revealed excellent correlation between CT and radiographic measurements for all subgroups (r = 0.97, P < .001). Paired-samples t-tests revealed no significant difference between methodologies for any of the subgroups. Radiographic and CT methods showed excellent agreement, and the bias between methods was within 0.5° for all subgroups. There was no fixed bias and thus no systematic difference in methods within any of the subgroup analyses. CONCLUSION Radiographic measurement of FA using a modified Budin view is a valid and reliable technique.
Collapse
|
464
|
Sagittal spinopelvic alignment predicts hip function after total hip arthroplasty. Gait Posture 2017; 52:293-300. [PMID: 28027530 DOI: 10.1016/j.gaitpost.2016.12.010] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2016] [Revised: 12/03/2016] [Accepted: 12/09/2016] [Indexed: 02/02/2023]
Abstract
The aim of this study was to investigate the association between preoperative sagittal spinopelvic alignment and postoperative clinical outcomes after total hip arthroplasty (THA). This retrospective study included 92 patients with hip osteoarthritis who underwent primary THA between May 2013 and October 2015. Patients' characteristics, radiographic sagittal spinopelvic parameters and modified Harris Hip Scores, including function scores (gait scores and functional activities scores), were investigated. Multivariate linear regression analysis was performed to determine the associations between each preoperative sagittal spinopelvic parameter and postoperative hip function The preoperative sagittal spinopelvic parameters that were associated with postoperative gait scores were sagittal vertical axis (adjusted β-coefficient=-0.28, P=0.02), lumbar lordosis angle (adjusted β-coefficient=0.29, P=0.0089), pelvic tilt (adjusted β-coefficient=-0.25, P=0.045), sacral slope (adjusted β-coefficient=0.27, P=0.017) and pelvic incidence minus lumbar lordosis angle (adjusted β-coefficient=-0.31, P=0.01). The preoperative sagittal spinopelvic parameters that were related to the postoperative functional activities scores were sagittal vertical axis (adjusted β-coefficient=-0.38, P=0.0051) and pelvic incidence minus lumbar lordosis angle (adjusted β-coefficient=-0.39, P=0.0033). Patients with preoperative imbalanced sagittal alignment such as larger sagittal vertical axis, larger pelvic incidence minus lumbar lordosis and retroversion of pelvis had poorer clinical outcomes than others after THA. While, those preoperative imbalanced patients with anteversion of pelvis may have a compensatory ability which could correct the abnormal sagittal alignment after THA. Preoperative sagittal spinopelvic alignment affected postoperative clinical outcomes after THA.
Collapse
|
465
|
A cadaver study validating CT assessment of acetabular component orientation: the Perth CT hip protocol. Skeletal Radiol 2017; 46:177-183. [PMID: 27826701 DOI: 10.1007/s00256-016-2527-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Accepted: 10/27/2016] [Indexed: 02/02/2023]
Abstract
OBJECTIVE The aim was to develop a CT-based protocol to accurately measure post-operative acetabular cup inclination and anteversion establishing which bony reference points facilitate the most accurate estimation of these variables. MATERIALS AND METHODS An all-polyethylene acetabular liner was implanted into a cadaveric acetabulum. A conventional pelvic CT scan was performed and reformatted images created in both functional and anterior pelvic planes. CT images were transferred to a Freedom-Plus Graphics software package enabling an identical, virtual 3D model of the cadaveric pelvis to be created and definitive acetabular cup orientation established. Using coronal and axial slices of the CT scans, acetabular cup inclination and anteversion were measured on five occasions by ten radiographers using differing predetermined bony landmarks as reference points. The intra- and inter-observer variation in measurement of acetabular cup orientation using varying bony reference points was assessed in comparison to the elucidated definitive cup position. RESULTS AND CONCLUSION Virtually derived definitive acetabular cup orientation was measured showing cup inclination and anteversion as 41.0 and 22.5° respectively. Mean CT-based measurement of cup inclination and anteversion by ten radiographers were 43.1 and 20.8° respectively. No statistically significant difference was found in intra- and inter-observer recorded results. No statistically significant differences were found when using different bony landmarks. CT assessment of acetabular component inclination and anteversion is accurate, reliable and reproducible when measured using differing bony landmarks as reference points. We recommend measuring acetabular inclination and anteversion from the inferior acetabular wall/teardrop and posterior ischium respectively.
Collapse
|
466
|
Aslanian T. All dual mobility cups are not the same. INTERNATIONAL ORTHOPAEDICS 2017; 41:573-581. [PMID: 28097387 DOI: 10.1007/s00264-016-3380-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Accepted: 12/19/2016] [Indexed: 02/08/2023]
Abstract
PURPOSE Although the natural history of dual mobility has been exclusively borne for 20 years by a single company (due to industrial ownership), the concept has undeniably been very widely popularised with nearly 40 cups on the French market which should be regarded as a weight bearing surface, both broadly and in their own right. However, within the same original idea, these implants are not all identical (design, material, fixation ect.).The aim of this work is to propose a classification of different dual mobility cups by distinguishing between thegeneral characteristics of a conventional cup and those particular to this type of implant. METHODS By comparison with a standard metal-back cup, dual mobility is based on at least one additional interface corresponding to the mobility of the polyethylene insert in the concavity of the acetabular cup called the outersurface. Design, constitutive material, fixation of the cup and characteristics of the retentive insert are analysed through the published results. RESULTS The complications associated, in particular, the intraprosthetic dislocation and to a lesser extent fixation failures undoubtedly condemned the dissemination of the dual mobility concept, as witnessed by the fact that despite the precedence of this 40-year old concept, the overriding majority of publications (more than 95%) have only appeared in the last ten years. CONCLUSION The latest generation of dual mobility cups combines: 1) a cast chrome-cobalt alloy cup covered with a bilayer coating of porous titanium and hydroxyapatite for long-term press-fit fixation to 2) an insert designed to eliminate all of the risks of intraprosthetic dislocation, whilst keeping all of the elasticity properties of the polyethylene, which has demonstrated its medium and long term effectiveness on preventing instability by overcoming other complications.
Collapse
|
467
|
Tsukamoto M, Ohnishi H, Mori T, Kawasaki M, Uchida S, Sakai A. Fifteen-Year Comparison of Wear and Osteolysis Analysis for Cross-Linked or Conventional Polyethylene in Cementless Total Hip Arthroplasty for Hip Dysplasia-A Retrospective Cohort Study. J Arthroplasty 2017; 32:161-165.e1. [PMID: 27444850 DOI: 10.1016/j.arth.2016.06.008] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2016] [Revised: 06/05/2016] [Accepted: 06/07/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Cross-linked polyethylene (XLPE) acetabular liners used in cementless total hip arthroplasty (THA) have demonstrated better wear resistance at 10 years compared with conventional polyethylene (CPE) liners. No clinical studies have compared XPLE to CPE liners beyond 10 years. METHODS We performed a 15-year retrospective cohort study on cementless THA performed in patients with developmental hip dysplasia to measure the differences in polyethylene wear rates and the presence of osteolysis. Twenty-four THAs with XLPE and 17 THAs with CPE were evaluated. The mean age of patients was 55.9 years (41-68) in the XLPE group and 54.4 years (40-67) in the CPE group. The mean follow-up period was 15.1 years (13.9-16.1) in the XLPE group and 15.2 years (14.5-16.0) in the CPE group. RESULTS The XLPE group had a significantly lower wear rate at 5 and 10 years compared with the CPE group; however, no significant difference was found at 15 years (XLPE group, 0.040 mm/y; CPE group, 0.034 mm/y). In addition, the incidence of osteolysis did not differ significantly between the groups. However, the incidence of excessive wear between 10 and 15 years after surgery in the XLPE group was significantly higher than that in the CPE group. CONCLUSION XLPE demonstrated no advantage in the wear rate or the incidence of osteolysis at 15 years, despite having superior wear resistance up to 10 years. It is concerning that the incidence of excessive wear was higher in the XLPE group between 10 and 15 years, and this finding should alert the arthroplasty community to this possible problem with the more highly cross-linked polyethylene.
Collapse
Affiliation(s)
- Manabu Tsukamoto
- Department of Orthopaedic Surgery, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Hideo Ohnishi
- Department of Orthopaedic Surgery, Moji Medical Center, Kitakyushu, Japan
| | - Toshiharu Mori
- Department of Orthopaedic Surgery, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Makoto Kawasaki
- Department of Orthopaedic Surgery, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Soshi Uchida
- Department of Orthopaedic Surgery, Wakamatsu Hospital for the University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Akinori Sakai
- Department of Orthopaedic Surgery, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
| |
Collapse
|
468
|
Abstract
Being one of the most successful surgeries in the history of medicine, the indications for total hip arthroplasty have widened and are increasingly being offered to younger and fitter patients. This has also led to high expectations for longevity and outcomes. Acetabular cup position has a significant impact on the results of hip arthroplasty as it affects dislocation, abductor muscle strength, gait, limb lengths, impingement, noise generation, range of motion (ROM), wear, loosening, and cup failure. The variables in cup position are depth, height, and angular position (anteversion and inclination). The implications of change in depth of center of rotation (COR) are medialized versus anatomical positioning. As opposed to traditional medialization with beneficial effects on joint reaction force, the advantages of an anatomical position are increasingly recognized. The maintained acetabular offset offers advantages in terms of ROM, impingement, cortical rim press fit, and maintaining medial bone stock. The height of COR influences muscle activity and limb lengths and available bone stock for cup support. On the other hand, ideal angular position remains a matter of much debate and reliably achieving a target angular position remains elusive. This is not helped by variations in the way we describe angular position, with operative, radiologic, or anatomic definitions being used variably to describe anteversion and inclination. Furthermore, pelvic tilt plays a major role in functional positions of the acetabulum. In addition, commonly used techniques of positioning often do not inform us of the real orientation of the pelvis on operating table, with possibility of significant adduction, flexion, and external rotation of the pelvis being possibilities. This review article brings together the evidence on cup positioning and aims to provide a systematic and pragmatic approach in achieving the best position in individual cases.
Collapse
Affiliation(s)
- Deepu Bhaskar
- Department of Trauma and Orthopaedics, Centre for Hip Surgery, Wrightington Hospital, Hall Lane, Appley Bridge, Lancashire WN6 9EP, UK
| | - Asim Rajpura
- Department of Trauma and Orthopaedics, Centre for Hip Surgery, Wrightington Hospital, Hall Lane, Appley Bridge, Lancashire WN6 9EP, UK
| | - Tim Board
- Department of Trauma and Orthopaedics, Centre for Hip Surgery, Wrightington Hospital, Hall Lane, Appley Bridge, Lancashire WN6 9EP, UK,Address for correspondence: Prof. Tim Board, Centre for Hip Surgery, Wrightington Hospital, Hall Lane, Appley Bridge, Lancashire WN6 9EP, UK. E-mail:
| |
Collapse
|
469
|
Ohashi H, Kikuchi S, Aota S, Hakozaki M, Konno S. Surgical anatomy of the pelvic vasculature, with particular reference to acetabular screw fixation in cementless total hip arthroplasty in Asian population. J Orthop Surg (Hong Kong) 2017; 25:2309499016685520. [PMID: 28498719 DOI: 10.1177/2309499016685520] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
PURPOSE Pelvic vascular injury is a serious complication associated with acetabular component setting with screw fixation in cementless total hip arthroplasty (THA). In this study, we investigated the safety zone for acetabular component setting with screw fixation in cementless THA as a means to prevent pelvic vascular injury. METHODS Thirty left hip joints of Japanese cadavers (11 males and 19 females) were analyzed. We used a hemispherical measuring cup with 52 guide holes designed to allow vertical insertion of a Kirschner wire. After the measuring cup was placed on the acetabulum, the Kirschner wire was inserted from each guide hole to examine the anatomical relationship between the acetabulum and the pelvic vessels. We calculated the frequency of pelvic vessel punctures and measured the distance from the acetabular surface to the pelvic vessels at each guide hole. RESULTS Our findings revealed that pelvic vessels do not exist in certain parts of the posterior area of the acetabulum. Furthermore, in this area, intrapelvic vessels are either lacking or located at a distance ≥31 mm from the surface of the acetabulum. CONCLUSION The posterior area of the acetabulum, excluding its central portion, appeared to be the safety zone for acetabular screw fixation in Japanese cadavers.
Collapse
Affiliation(s)
- Hironori Ohashi
- Department of Orthopaedic Surgery, Fukushima Medical University School of Medicine, Fukushima, Japan
| | - Shinichi Kikuchi
- Department of Orthopaedic Surgery, Fukushima Medical University School of Medicine, Fukushima, Japan
| | - Shigeo Aota
- Department of Orthopaedic Surgery, Fukushima Medical University School of Medicine, Fukushima, Japan
| | - Michiyuki Hakozaki
- Department of Orthopaedic Surgery, Fukushima Medical University School of Medicine, Fukushima, Japan
| | - Shinichi Konno
- Department of Orthopaedic Surgery, Fukushima Medical University School of Medicine, Fukushima, Japan
| |
Collapse
|
470
|
Abstract
BACKGROUND Femoral bowing plane (FBP) is the unattended subject in the literature. More over the femoral shaft with its bowing is neglected in established anteversion determination methods. There is limited information about the relationship between FBP and anteversion. Thus we focused on this subject and hypothesized that there could be an adaptation of FBP to anteversion. MATERIALS AND METHODS FBP is determined on three-dimensional solid models derived from the left femoral computerized tomography data of 47 patients which were taken before for another reason and comparatively evaluated with anteversion. There were 20 women and 27 men. The mean age of patients was 56 years (range 21-84 years). RESULTS The anteversion values were found as the angle between a distal condylar axis (DCA) and femoral neck anteversion axis (FNAA) along an imaginary longitudinal femoral axis (LFA) in the true cranio-caudal view. The FBP was determined as a plane that passes through the centre-points of three pre-determinated sections on the femoral shaft. The angles between DCA, FNAA and FBP were comparatively evaluated. The independent samples t-test was used for statistical analysis. At the end, it was found that FBP lies nearly perpendicular to the anteversion axis for the mean of our sample which is around 89° in females and 93° in males (range 78-102°). On the other hand, FBP does not lie close to the sagittal femoral plane (SFP); instead, there is an average 12.5° external rotation relative to the SFP. FBP is correlated well with anteversion in terms of FBP inclination from SFP and femoral torsion (i.e., angle between FBP and femoral neck anteversion axis (P < 0.001; r = 0.680 and r = -0.682, respectively). Combined correlation is perfect (R2 = 1) as the FBP, SFP, and posterior femoral plane forms a triangle in the cranio-caudal view. CONCLUSIONS We found that FBP adapts to anteversion. As FBP lies close to perpendicularity for the mean, femoral component positioning perpendicular to the FBP can be an alternate way in the replacement surgeries. In addition, it has been found that FBP lies externally rotated relative to the SFP.
Collapse
Affiliation(s)
- Alp Akman
- Department of Orthopaedics and Traumatology, School of Medicine, Pamukkale University, Denizli, Turkey,Address for correspondence: Dr. Alp Akman, Department of Orthopaedics and Traumatology, School of Medicine, Pamukkale University, 20160 Kinikli, Denizli, Turkey. E-mail:
| | - Fahir Demirkan
- Department of Orthopaedics and Traumatology, School of Medicine, Pamukkale University, Denizli, Turkey
| | - Nuran Sabir
- Department of Radiology, School of Medicine, Pamukkale University, Denizli, Turkey
| | - Murat Oto
- Department of Orthopaedics and Traumatology, School of Medicine, Pamukkale University, Denizli, Turkey
| | - Cagdas Yorukoglu
- Department of Orthopaedics and Traumatology, School of Medicine, Pamukkale University, Denizli, Turkey
| | - Esat Kiter
- Department of Orthopaedics and Traumatology, School of Medicine, Pamukkale University, Denizli, Turkey
| |
Collapse
|
471
|
Daniel M, Rijavec B, Dolinar D, Pokorný D, Iglič A, Kralj-Iglič V. Patient-specific hip geometry has greater effect on THA wear than femoral head size. J Biomech 2016; 49:3996-4001. [PMID: 27842781 DOI: 10.1016/j.jbiomech.2016.10.030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2016] [Revised: 10/19/2016] [Accepted: 10/21/2016] [Indexed: 11/17/2022]
Abstract
In vivo linear penetration in total hip arthroplasty (THA) exhibits similar values for 28mm and 32mm femoral head diameter with considerable variations between and within the studies. It indicates factors other than femoral head diameter influence polyethylene wear. This study is intended to test the effect of patient׳s individual geometry of musculoskeletal system, acetabular cup orientation, and radius of femoral head on wear. Variation in patient׳s musculoskeletal geometry and acetabular cup placement is evaluated in two groups of patients implanted with 28mm and 32mm THA heads. Linear wear rate estimated by mathematical model is 0.165-0.185mm/year and 0.157-0.205mm/year for 28 and 32mm THA heads, respectively. Simulations show little influence femoral head size has on the estimated annual wear rate. Predicted annual linear wear depends mostly on the abduction angle of the acetabular cup and individual geometry of the musculoskeletal system of the hip, with the latter having the greatest affect on variation in linear wear rate.
Collapse
Affiliation(s)
- Matej Daniel
- Faculty of Mechanical Engineering, Czech Technical University in Prague, Czechia.
| | - Boris Rijavec
- Laboratory of Clinical Biophysics, Faculty of Health Sciences, University of Ljubljana, Slovenia
| | - Drago Dolinar
- Department of Orthopaedic Surgery, University Medical Centre Ljubljana, Ljubljana, Slovenia
| | - David Pokorný
- 1st Faculty of Medicine, Charles University, Prague, Czechia
| | - Aleš Iglič
- Laboratory of Biophysics, Faculty of Electrical Engineering, University of Ljubljana, Slovenia
| | - Veronika Kralj-Iglič
- Laboratory of Clinical Biophysics, Faculty of Health Sciences, University of Ljubljana, Slovenia
| |
Collapse
|
472
|
Repeated posterior dislocation of total hip arthroplasty after spinal corrective long fusion with pelvic fixation. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2016; 26:100-106. [DOI: 10.1007/s00586-016-4880-y] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2016] [Revised: 09/24/2016] [Accepted: 11/11/2016] [Indexed: 10/20/2022]
|
473
|
Batailler C, Fary C, Batailler P, Servien E, Neyret P, Lustig S. Total hip arthroplasty using direct anterior approach and dual mobility cup: safe and efficient strategy against post-operative dislocation. INTERNATIONAL ORTHOPAEDICS 2016; 41:499-506. [PMID: 27853816 DOI: 10.1007/s00264-016-3333-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2016] [Accepted: 10/31/2016] [Indexed: 12/27/2022]
Abstract
AIM We hypothesize that a dual mobility cup can be safely used via the direct anterior approach, without increasing the risk of complications or incorrect positioning. MATERIALS AND METHODS This retrospective study compared 201 primary total hip arthroplasties using a dual mobility cup performed via direct anterior approach without a traction table, to 101 arthroplasties performed via posterolateral approach. Implant positioning, function scores, and early complications were recorded. RESULTS Implant positioning was appropriate in both groups, with a higher cup anteversion in direct anterior approach. The complications rates were similar in both groups, with no dislocation or infection. CONCLUSION The direct anterior approach without traction table associated with a dual mobility cup does not increase the risk of complications or non-optimal positioning of implants. This strategy is interesting for patients with high risk of post-operative dislocation.
Collapse
Affiliation(s)
- Cécile Batailler
- Albert Trillat Center, Lyon North University Hospital, Lyon, France
| | | | - Pierre Batailler
- Public Health Center, Grenoble University Hospital, Grenoble, France
| | - Elvire Servien
- Albert Trillat Center, Lyon North University Hospital, Lyon, France
| | - Philippe Neyret
- Albert Trillat Center, Lyon North University Hospital, Lyon, France
| | - Sébastien Lustig
- Albert Trillat Center, Lyon North University Hospital, Lyon, France.
| |
Collapse
|
474
|
Fujihara Y, Fukunishi S, Fukui T, Nishio S, Okahisa S, Takeda Y, Kurosaka K, Yoshiya S. Use of the G-guide for Measuring Stem Antetorsion During Total Hip Arthroplasty. Orthopedics 2016; 39:e271-5. [PMID: 26881466 DOI: 10.3928/01477447-20160201-03] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2015] [Accepted: 07/17/2015] [Indexed: 02/03/2023]
Abstract
Implant positioning is one of the critical factors influencing postoperative outcomes in total hip arthroplasty (THA). Several studies have reported that the postoperative antetorsion (AT) measurement for the femoral stem inserted without navigation showed wide variability. The current authors developed a simple instrument, the Gravity-guide (G-guide), for intraoperative assessment of stem AT and adjustment. They evaluated the effectiveness of the G-guide with postoperative computed tomography (CT) examination. Ninety patients (96 hips) who underwent primary THA using the G-guide for stem adjustment were evaluated. The G-guide consists of 2 parts: one attached to the lower leg and the other attached to the handle of the rasp. The G-guide was used to evaluate the AT at the time of inserting the final rasp. In addition, the AT value in the G-guide evaluation system required correction by the angle obtained in the preoperative epicondylar view. Intraoperative stem AT was defined as the sum of the intraoperative G-guide value and the correction angle. Postoperative AT was evaluated by CT examination. The discrepancy between the intra- and postoperative measurements was 4.6°±4.1°. Acceptable accuracy with discrepancy of less than 5° and 10° was achieved in 66 (69%) hips and 85 (89%) hips, respectively. The use of the G-guide could effectively reduce the variability of stem anteversion compared with manual adjustment. This study proved the effectiveness of the newly developed G-guide system in intraoperative stem AT adjustment.
Collapse
|
475
|
Primary total hip arthroplasty using modified posterior approach through quadratus femoris flap osteotomy; comparison with conventional posterior approach. Hip Int 2016; 26:543-549. [PMID: 27739570 DOI: 10.5301/hipint.5000390] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 03/13/2016] [Indexed: 02/04/2023]
Abstract
INTRODUCTION The quadratus femoris muscle has not attracted attention as a structure for surgical exposure during posterior hip approaches. We sought to introduce a modified posterior approach through the quadratus femoris muscle area only, by flap osteotomy, which we have named the quadratus femoris osteotomy (QFO) approach. We compare this with the conventional posterior approach to determine the effectiveness of the new technique. METHODS We retrospectively reviewed the medical records of 329 patients (383 hips) who had undergone primary total hip arthroplasty (THA) between March 2006 and January 2013 by a single hip surgeon. The conventional group consisted of consecutive 118 patients (138 hips) who had undergone THA using the conventional posterior approach. The QFO group consisted of consecutive 101 patients (120 hips) who were treated with THA using the QFO approach. RESULTS The 2-year postoperative average Harris hip score were 88.8 ± 6.6 in the conventional group and 93.1 ± 6.9 in the QFO group. The 2-year postoperative average WOMAC scores were 20.8 ± 6.7 in the conventional group and 14.1 ± 6.6 in the QFO group. Complications in the conventional group were 2 deep vein thrombosis (DVT)s, 1 intraoperative fracture, and 6 posterior dislocations; the QFO group experienced 1 DVT and 3 intraoperative fracture. No dislocation was noted within 2 years after surgery. CONCLUSIONS Although further studies are needed to confirm the validity of our findings, a modified posterior approach using a quadratus femoris flap osteotomy could be an option worth considering among the variants of posterior approaches in THA.
Collapse
|
476
|
Weber M, Woerner ML, Sendtner E, Völlner F, Grifka J, Renkawitz TF. Even the Intraoperative Knowledge of Femoral Stem Anteversion Cannot Prevent Impingement in Total Hip Arthroplasty. J Arthroplasty 2016; 31:2514-2519. [PMID: 27236745 DOI: 10.1016/j.arth.2016.04.024] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2016] [Revised: 04/16/2016] [Accepted: 04/21/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND In this prospective study of 66 patients undergoing cementless total hip arthroplasty through a minimally invasive anterolateral approach, we evaluated the impact of an intraoperative hybrid combined anteversion technique on postoperative range of motion (ROM). METHODS After navigation of femoral stem anteversion, trial acetabular components were positioned manually, and their position recorded with navigation. Then, final components were implanted with navigation at the goals prescribed by the femur-first impingement detection algorithm. Postoperatively, three-dimensional computed tomographies were performed to determine achieved component position and model impingement-free ROM by virtual hip movement, which was compared with published values necessary for activities of daily living. This model was run a second time with the implants in the position selected by the surgeon rather than the navigation program. In addition, we researched into risk factors for ROM differences between the freehand and navigated cup position. RESULTS We found a lower flexion of 8.3° (8.8°, P < .001) and lower internal rotation of 9.2° (9.5°, P < .001) for the freehand implanted cups in contrast to a higher extension of 9.8° (11.8°, P < .001) compared with the navigation-guided technique. For activities of daily living, 58.9% (33/56) in the freehand group compared with 85.7% (48/56) in the navigation group showed free flexion (P < .001) and similarly 50.0% (28/56) compared with 76.8% (43/56) free internal rotation (P < .001). Body mass index, incision length, and cup size were identified as independent risk factors for reduced flexion and internal rotation in the freehand group. CONCLUSION For implementation of a combined anteversion algorithm, intraoperative alignment guides for accurate cup positioning are required using a minimally invasive anterolateral approach. Obese patients are especially at risk of cup malpositioning.
Collapse
MESH Headings
- Acetabulum/surgery
- Activities of Daily Living
- Aged
- Arthroplasty, Replacement, Hip/adverse effects
- Arthroplasty, Replacement, Hip/instrumentation
- Arthroplasty, Replacement, Hip/methods
- Female
- Femoracetabular Impingement/etiology
- Femoracetabular Impingement/prevention & control
- Femur/surgery
- Hip Joint/diagnostic imaging
- Humans
- Male
- Middle Aged
- Models, Theoretical
- Postoperative Complications/etiology
- Postoperative Complications/prevention & control
- Postoperative Period
- Prospective Studies
- Range of Motion, Articular
- Rotation
- Surgery, Computer-Assisted/methods
- Tomography, X-Ray Computed
Collapse
Affiliation(s)
- Markus Weber
- Department of Orthopedic Surgery, Regensburg University, Medical Center, Bad Abbach, Germany
| | - Michael L Woerner
- Department of Orthopedic Surgery, Regensburg University, Medical Center, Bad Abbach, Germany
| | - Ernst Sendtner
- Department of Orthopedic and Trauma Surgery, Vilsbiburg Hospital, Vilsbiburg, Germany
| | - Florian Völlner
- Department of Orthopedic Surgery, Regensburg University, Medical Center, Bad Abbach, Germany
| | - Joachim Grifka
- Department of Orthopedic Surgery, Regensburg University, Medical Center, Bad Abbach, Germany
| | - Tobias F Renkawitz
- Department of Orthopedic Surgery, Regensburg University, Medical Center, Bad Abbach, Germany
| |
Collapse
|
477
|
Dual-mobility implants prevent hip dislocation following hip revision in obese patients. INTERNATIONAL ORTHOPAEDICS 2016; 41:469-473. [PMID: 27761631 DOI: 10.1007/s00264-016-3316-y] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2016] [Accepted: 10/10/2016] [Indexed: 01/20/2023]
Abstract
PURPOSE Revision total hip arthroplasty (THA) is associated with increased rates of dislocation in obese patients. It is not known whether dual-mobility implants decrease dislocation in these patients with obesity. METHODS We retrospectively reviewed two groups of revision THAs to compare the dislocation rate between 32 obese patients (BMI >30 kg/m2) with standard cups, and 35 obese patients (BMI >30 kg/m2) with dual-mobility cups. All patients received the same implants except for diameter head (32-mm head with standard cups and 28-mm head with dual mobility) and had the same cemented stem that was not changed at revision. The patients were followed at routine intervals and were specifically queried about dislocation. The two groups were similar in terms of age, gender, causes of revision and follow-up since the primary arthroplasty. RESULTS With standard liners, more hips in obese patients dislocated than did hips in obese patients who received dual-mobility implants. The number of dislocations in standard hips was at one year follow-up 15.6 % (5 of 32) compared with 0 % in dual-mobility hips and was at five year follow-up 21.8 % (7 of 32) compared with 2.8 % (1 of 35). After a mean follow-up of seven years no cases of loosening were found. Five patients in the obese group with a standard liner underwent re-revision surgery, the additional re-operations being necessary to treat recurrent postoperative dislocation. CONCLUSIONS Obese patients should be counselled about the important risk of dislocation that occurs with standard liners after revision THA. Dual-mobility liners in these patients with hip revision is an efficient technique to prevent post-operative hip dislocation.
Collapse
|
478
|
Schwarz T, Weber M, Wörner M, Renkawitz T, Grifka J, Craiovan B. Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study. Int J Comput Assist Radiol Surg 2016; 12:829-837. [PMID: 27714567 DOI: 10.1007/s11548-016-1489-x] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Accepted: 09/27/2016] [Indexed: 11/29/2022]
Abstract
PURPOSE Accurate assessment of cup orientation on postoperative radiographs is essential for evaluating outcome after THA. However, accuracy is impeded by the deviation of the central X-ray beam in relation to the cup and the impossibility of measuring retroversion on standard pelvic radiographs. METHOD In an experimental trial, we built an artificial cup holder enabling the setting of different angles of anatomical anteversion and inclination. Twelve different cup orientations were investigated by three examiners. After comparing the two methods for radiographic measurement of the cup position developed by Lewinnek and Widmer, we showed how to differentiate between anteversion and retroversion in each cup position by using a second plane. To show the effect of the central beam offset on the cup, we X-rayed a defined cup position using a multidirectional central beam offset. According to Murray's definition of anteversion and inclination, we created a novel corrective procedure to balance measurement errors caused by deviation of the central beam. RESULTS Measurement of the 12 different cup positions with the Lewinnek's method yielded a mean deviation of [Formula: see text] (95 % CI 1.3-2.3) from the original cup anteversion. The respective deviation with the Widmer/Liaw's method was [Formula: see text] (95 % CI 2.4-4.0). In each case, retroversion could be differentiated from anteversion with a second radiograph. Because of the multidirectional central beam offset ([Formula: see text] cm) from the acetabular cup in the cup holder ([Formula: see text] anteversion and [Formula: see text] inclination), the mean absolute difference for anteversion was [Formula: see text] (range [Formula: see text] to [Formula: see text] and [Formula: see text] (range [Formula: see text] to [Formula: see text] for inclination. The application of our novel mathematical correction of the central beam offset reduced deviation to a mean difference of [Formula: see text] for anteversion and [Formula: see text] for inclination. CONCLUSION This novel calculation for central beam offset correction enables highly accurate measurement of the cup position.
Collapse
Affiliation(s)
- T Schwarz
- Department of Orthopedic Surgery, Regensburg University Medical Center, Kaiser-Karl-V.-Allee 3, 93077, Bad Abbach, Germany.
| | - M Weber
- Department of Orthopedic Surgery, Regensburg University Medical Center, Kaiser-Karl-V.-Allee 3, 93077, Bad Abbach, Germany
| | - M Wörner
- Department of Orthopedic Surgery, Regensburg University Medical Center, Kaiser-Karl-V.-Allee 3, 93077, Bad Abbach, Germany
| | - T Renkawitz
- Department of Orthopedic Surgery, Regensburg University Medical Center, Kaiser-Karl-V.-Allee 3, 93077, Bad Abbach, Germany
| | - J Grifka
- Department of Orthopedic Surgery, Regensburg University Medical Center, Kaiser-Karl-V.-Allee 3, 93077, Bad Abbach, Germany
| | - B Craiovan
- Department of Orthopedic Surgery, Regensburg University Medical Center, Kaiser-Karl-V.-Allee 3, 93077, Bad Abbach, Germany
| |
Collapse
|
479
|
Zhao JX, Su XY, Xiao RX, Zhao Z, Zhang LH, Zhang LC, Tang PF. A mathematical method for precisely calculating the radiographic angles of the cup after total hip arthroplasty. Med Eng Phys 2016; 38:1376-1381. [PMID: 27720337 DOI: 10.1016/j.medengphy.2016.09.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2015] [Revised: 08/18/2016] [Accepted: 09/23/2016] [Indexed: 11/19/2022]
Abstract
We established a mathematical method to precisely calculate the radiographic anteversion (RA) and radiographic inclination (RI) angles of the acetabular cup based on anterior-posterior (AP) pelvic radiographs after total hip arthroplasty. Using Mathematica software, a mathematical model for an oblique cone was established to simulate how AP pelvic radiographs are obtained and to address the relationship between the two-dimensional and three-dimensional geometry of the opening circle of the cup. In this model, the vertex was the X-ray beam source, and the generatrix was the ellipse in radiographs projected from the opening circle of the acetabular cup. Using this model, we established a series of mathematical formulas to reveal the differences between the true RA and RI cup angles and the measurements results achieved using traditional methods and AP pelvic radiographs and to precisely calculate the RA and RI cup angles based on post-operative AP pelvic radiographs. Statistical analysis indicated that traditional methods should be used with caution if traditional measurements methods are used to calculate the RA and RI cup angles with AP pelvic radiograph. The entire calculation process could be performed by an orthopedic surgeon with mathematical knowledge of basic matrix and vector equations.
Collapse
Affiliation(s)
- Jing-Xin Zhao
- Department of Orthopaedics, Chinese PLA General Hospital, Beijing 100853, People's Republic of China.
| | - Xiu-Yun Su
- Department of Orthopaedics, Affiliated Hospital of the Academy of Military Medical Sciences, No. 8 Dongdajie Road, Beijing 100071, People's Republic of China; Department of Orthopaedics, Chinese PLA General Hospital, Beijing 100853, People's Republic of China.
| | - Ruo-Xiu Xiao
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, People's Republic of China.
| | - Zhe Zhao
- Department of Orthopaedics, Beijing Tsinghua Chang Gung Hospital, No. 1 Block Tiantongyuan North, Beijing 102218, People's Republic of China; Department of Orthopaedics, Chinese PLA General Hospital, Beijing 100853, People's Republic of China.
| | - Li-Hai Zhang
- Department of Orthopaedics, Chinese PLA General Hospital, Beijing 100853, People's Republic of China.
| | - Li-Cheng Zhang
- Department of Orthopaedics, Chinese PLA General Hospital, Beijing 100853, People's Republic of China.
| | - Pei-Fu Tang
- Department of Orthopaedics, Chinese PLA General Hospital, Beijing 100853, People's Republic of China.
| |
Collapse
|
480
|
Noback PC, Danoff JR, Herschmiller T, Bobman JT, Shah RP, Geller JA, Macaulay W. Plain Radiographs are a Useful Substitute for Computed Tomography in Evaluating Acetabular Cup Version. J Arthroplasty 2016; 31:2320-4. [PMID: 27181489 DOI: 10.1016/j.arth.2016.03.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 02/22/2016] [Accepted: 03/07/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study is to compare acetabular component version measurements from cross-table lateral (XTL) radiographs, anteroposterior pelvis (AP-P) and anteroposterior hip (AP-H) radiographs, and axial pelvic computed tomography (CT) scans. METHODS One hundred fifty hips met our inclusion criteria of having a CT, XTL, and AP-P done postoperatively. Version was measured by 2 authors. Pearson regression analysis assessed correlation between versions of the modalities. Analysis of variance testing compared the averages of the values as a whole and based on demographics. When available, comparisons were also done with AP-H radiographs. RESULTS Mean version for XTL and CT scan was 21.7° and 23.8°, respectively, whereas that from AP-P and AP-H radiographs was 12.5° and 17.2°, respectively. XTL and AP-H version measures were closely correlated with CT (P = .81), whereas AP-P measurements were only moderately correlated with CT (P = .75). AP-P and AP-H were significantly (P < .05) different from CT, whereas XTL was not (P = .36). CONCLUSION The XTL radiograph remains a useful, cheaper, and safer substitute for CT scan when assessing supine version in the postoperative setting.
Collapse
Affiliation(s)
- Peter C Noback
- Center for Hip and Knee Replacement, Department of Orthopedic Surgery, NewYork-Presbyterian Hospital/Columbia University Medical Center, New York, New York
| | - Jonathan R Danoff
- Center for Hip and Knee Replacement, Department of Orthopedic Surgery, NewYork-Presbyterian Hospital/Columbia University Medical Center, New York, New York
| | - Thomas Herschmiller
- Center for Hip and Knee Replacement, Department of Orthopedic Surgery, NewYork-Presbyterian Hospital/Columbia University Medical Center, New York, New York
| | - Jacob T Bobman
- Center for Hip and Knee Replacement, Department of Orthopedic Surgery, NewYork-Presbyterian Hospital/Columbia University Medical Center, New York, New York
| | - Roshan P Shah
- Center for Hip and Knee Replacement, Department of Orthopedic Surgery, NewYork-Presbyterian Hospital/Columbia University Medical Center, New York, New York
| | - Jeffrey A Geller
- Center for Hip and Knee Replacement, Department of Orthopedic Surgery, NewYork-Presbyterian Hospital/Columbia University Medical Center, New York, New York
| | - William Macaulay
- Center for Hip and Knee Replacement, Department of Orthopedic Surgery, NewYork-Presbyterian Hospital/Columbia University Medical Center, New York, New York
| |
Collapse
|
481
|
Komiyama K, Nakashima Y, Hirata M, Hara D, Kohno Y, Iwamoto Y. Does High Hip Center Decrease Range of Motion in Total Hip Arthroplasty? A Computer Simulation Study. J Arthroplasty 2016; 31:2342-7. [PMID: 27067755 DOI: 10.1016/j.arth.2016.03.014] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Revised: 03/01/2016] [Accepted: 03/07/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND High placement of a cementless acetabular cup is often required to have sufficient bone coverage in hip dysplasia. We examined whether a high hip center decreases the postoperative range of motion (ROM) in total hip arthroplasty. METHODS Using a computer software, ROM and bone coverage were examined in 32 patients with unilateral osteoarthritis of the hip with Crowe type II or III hip dysplasia. The cup was placed at the anatomic hip center and moved vertically in 5-mm increments. Vertical center of rotation (V-COR) was defined as the distance from the head center to the interteardrop line. The required ROM was defined as flexion ≥110°, internal rotation (IR) at 90° flexion ≥30°, extension ≥30°, and external rotation ≥30°. We determined the V-COR to satisfy the required ROM and cup center-edge angle (Cup-CE) ≥0°. RESULTS Only 40.6% of the patients satisfied Cup-CE ≥0° at the anatomic hip center. Bone coverage increased with the peak at 30, 35 mm of V-COR (90.6% satisfied Cup-CE ≥0°) and decreased at ≥40 mm. Higher V-COR resulted in lower range of flexion and IR, but increased the range of extension and external rotation. The cutoff value from the receiver-operating characteristic curve for both flexion and IR was a V-COR of 35 mm. CONCLUSION The higher hip center gained more bone coverage but decreased the range of hip flexion and IR. Acceptable V-COR in hip dysplasia was around 35 mm, about 20 mm above the true hip center, in terms of ROM.
Collapse
Affiliation(s)
- Keisuke Komiyama
- Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Yasuharu Nakashima
- Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Masanobu Hirata
- Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Daisuke Hara
- Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Yusuke Kohno
- Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Yukihide Iwamoto
- Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| |
Collapse
|
482
|
Hernigou P, Trousselier M, Roubineau F, Bouthors C, Flouzat Lachaniette CH. Dual-mobility or Constrained Liners Are More Effective Than Preoperative Bariatric Surgery in Prevention of THA Dislocation. Clin Orthop Relat Res 2016; 474:2202-10. [PMID: 27130648 PMCID: PMC5014805 DOI: 10.1007/s11999-016-4859-3] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Obesity is associated with an increased risk of dislocation after total hip arthroplasty (THA). However, in patients with obesity, it is not known whether the risk is only in the early postoperative period or whether it persists several years after surgery, and whether having bariatric surgery before undergoing THA and/or receiving a specific device (such as a dual-mobility or constrained acetabular liner) is more effective in terms of decreasing the risk of dislocation. QUESTION/PURPOSES (1) What is the cumulative risk of dislocation in patients with obesity after THA in the absence of a dual-mobility or constrained liner, and is this related to component positioning? (2) Does bariatric surgery before undergoing THA decrease dislocation risk in patients with obesity? (3) Are dual-mobility and constrained liners efficient in preventing dislocation in patients with obesity? METHODS At our university-based practice, all surgeons adhered to the following treatment approaches: Before 2000 no dual-mobility implants or constrained liners were used for primary THAs. Between 2000 and 2008, all patients whose body mass index (BMI) was greater than 30 kg/m(2) received dual-mobility liners (or constrained liners), except when they had previously had bariatric surgery. After 2008, all patients with BMIs over 30 kg/m(2) as well as those patients who were previously treated with bariatric surgery (regardless of BMI at the time of the index THA) received dual-mobility or constrained liners. This case-control study compared the dislocation percentage between 215 hips in nonobese patients (BMI ≤ 30 kg/m(2)), 215 hips in patients with obesity (BMI > 30 kg/m(2)) who received standard cups, 85 hips in patients with bariatric surgery before THA using standard cups (with reduction to a BMI < 30 kg/m(2)), and 155 hips in patients with obesity who received dual-mobility (when younger than 70 years) or constrained liners (when older than 70 years). All patients received the same implants except for different femoral head diameters (32-mm head with standard cups and 28-mm head with dual-mobility or constrained liners). The patients were followed at routine intervals and were specifically queried about dislocation. All the 670 hips had a minimum followup of 5 years with a mean followup of 14 years (range 5-25 years). At the most recent followup, 101 (15%) hips were lost to followup (respectively, 36 of 215, 34 of 215, five of 85, 24 of 155), which is the same ratio as observed among the underlying populations from which the patients were drawn. RESULTS With standard liners, more hips in patients with BMI > 30 kg/m(2) dislocated than did hips in nonobese (BMI < 30 kg/m(2)) patients. The cumulative number of dislocations (first time without recurrent dislocation) was 6% (13 of 215) at 1-year followup in obese patients compared with 2% (four of 215) in nonobese patients (odds ratio [OR], 3.4; 95% confidence interval [CI] 1.09-10.58; p = 0.03) and was 13% (28 of 215) at 15 years followup compared with 4% (eight of 215) in nonobese patients (OR, 3.9; 95% CI 1.72-8.71; p = 0.001). When bariatric surgery was performed before THA, BMI declined from 42 kg/m(2) to 28 kg/m(2), but with the same standard liners, more hips after bariatric surgery dislocated at 1-year followup than did hips in patients with obesity without preoperative bariatric surgery (13% [11 of 85] compared with 6% [13 of 215]; OR, 0.43; 95% CI 0.18-1.01; p = 0.05). Dual-mobility or constrained implants decreased the risk of dislocation, and fewer hips in patients with obesity with dual-mobility or constrained liners at 7 years followup had dislocated than did hips with standard liners (2% [three of 155] compared with 9% [20 of 215]; OR, 0.19; 95% CI 0.05-0.66; p = 0.01) bringing this number in line with the number observed in nonobese subjects with standard cups. CONCLUSIONS With standard liners, the risk of dislocation is increased in patients with obesity. Preoperative decrease of BMI (with bariatric surgery) in patients with obesity did not prevent the risk of dislocation with standard liners. Use of dual-mobility or constrained liners in these patients is an effective technique to reduce the risk of postoperative hip dislocation. However, we do not yet know the full risks of loosening of dual-mobility and constrained liners in this obese population. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Philippe Hernigou
- Department of Orthopaedic Surgery, Hospital Henri Mondor, University Paris East, 94010 Creteil, France
| | - Matthieu Trousselier
- Department of Orthopaedic Surgery, Hospital Henri Mondor, University Paris East, 94010 Creteil, France
| | - François Roubineau
- Department of Orthopaedic Surgery, Hospital Henri Mondor, University Paris East, 94010 Creteil, France
| | - Charlie Bouthors
- Department of Orthopaedic Surgery, Hospital Henri Mondor, University Paris East, 94010 Creteil, France
| | | |
Collapse
|
483
|
Worlicek M, Weber M, Craiovan B, Wörner M, Völlner F, Springorum HR, Grifka J, Renkawitz T. Native femoral anteversion should not be used as reference in cementless total hip arthroplasty with a straight, tapered stem: a retrospective clinical study. BMC Musculoskelet Disord 2016; 17:399. [PMID: 27646313 PMCID: PMC5028956 DOI: 10.1186/s12891-016-1255-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2015] [Accepted: 09/13/2016] [Indexed: 11/25/2022] Open
Abstract
Backround Improper femoral and acetabular component positioning can be associated with instability, impingement, component wear and finally patient dissatisfaction in total hip arthroplasty (THA). The concept of “femur first”/“combined anteversion”, incorporates various aspects of performing a functional optimization of the prosthetic stem and cup position of the stem relative to the cup intraoperatively. In the present study we asked two questions: (1) Do native femoral anteversion and anteversion of the implant correlate? (2) Do anteversion of the final broach and implant anteversion correlate? Methods In a secondary analysis of a prospective controlled trial, a subgroup of 55 patients, who underwent computer-assisted, cementless THA with a straight, tapered stem through an anterolateral, minimally invasive (MIS) approach in a lateral decubitus position were examined retrospectivly. Intraoperative fluoroscopy was used to verify a “best-fit” position of the final broach. An image-free navigation system was used for measurement of the native femoral version, version of the final broach and the final implant. Femoral neck resection height was measured in postoperative CT-scans. This investigation was approved by the local Ethics Commission (No.10-121-0263) and is a secondary analysis of a larger project (DRKS00000739, German Clinical Trials Register May-02–2011). Results The mean difference between native femoral version and final implant was 1.9° (+/− 9.5), with a range from −20.7° to 21.5° and a Spearman’s correlation coefficient of 0.39 (p < 0.003). In contrast, we observed a mean difference between final broach and implant version of −1.9° (+/− 3.5), with a range from −12.7° to 8.7° and a Spearman’s correlation coefficient of 0.89 (p < 0.001). In 83.6 % (46/55) final stem version was outside the normal range as defined by Tönnis (15-20°). The mean femoral neck resection height was 7.3 mm (+/− 5.6). There was no correlation between resection height and version of the implant (Spearman’s correlation coefficient 0.14). Conclusion Native femoral version significantly differs from the final anteversion of a cementless, straight, tapered stem and therefore is not a reliable reference in cementless THA. Measuring anteversion of the final “fit and fill” broach is a feasible assistance in order to predict final stem anteversion intraoperatively. There is no correlation between femoral neck resection height and version of the implant.
Collapse
Affiliation(s)
- Michael Worlicek
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany.
| | - Markus Weber
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| | - Benjamin Craiovan
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| | - Michael Wörner
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| | - Florian Völlner
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| | - Hans R Springorum
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| | - Joachim Grifka
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| | - Tobias Renkawitz
- Departement of Orthopedic Surgery, University of Regensburg, Asklepios Medical Centre, Kaiser-Karl-V-Allee 3, D-93077, Bad Abbach, Germany
| |
Collapse
|
484
|
Midterm Survivorship of the Lefèvre Constrained Liner: A Consecutive Multisurgeon Series of 166 Cases. J Arthroplasty 2016; 31:1970-8. [PMID: 27006147 DOI: 10.1016/j.arth.2016.02.031] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 02/16/2016] [Accepted: 02/16/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Constrained liners are used as part of a salvage procedure to provide stability for patients at high risk for dislocation after a total hip arthroplasty. However, no recent studies exist highlighting their effectiveness and/or limitations. METHOD This prospective review included 166 consecutive hip arthroplasties, either primary (27%) or revision (73%), with a unique design of a constrained liner: Lefèvre retentive cup. There were 113 females (69%), and the average age at index surgery was 75.9 years (range, 35-94). The mean follow-up was 6.2 years (range, 0.3-11). RESULTS Twenty patients had a reoperation; 10 for infection (4 acute and 6 chronic joint infection) and 10 for cup failure (5 fixation failure, 3 aseptic loosening, and 2 dislocation). Ten-year survivals for cup revision were 89% (CI, 83-94) and 92% (CI, 89-97) for all revision and revision for noninfectious reasons, respectively. When solely evaluating for dislocation, the survival at 10 years was 99% (CI, 97-100). Considering primary and revision cases, 10-year survivals cup revision for aseptic reasons were 92.4% (CI, 84-100) and 92.5% (CI, 87-98), respectively. CONCLUSIONS The Lefèvre retentive cup demonstrated excellent 10-year's survivorship. With the rate of aseptic loosening around 2% and a dislocation rate around 1%, the cup is as effective as other available devices and is therefore a cost-effective tool to reduce the risk of dislocation in at-risk patients undergoing hip arthroplasty.
Collapse
|
485
|
Jauregui JJ, Banerjee S, Elmallah RK, Pierce TP, Cherian JJ, Harwin SF, Mont MA. Radiographic Evaluation of Hip Dislocations Necessitating Revision Total Hip Arthroplasty. Orthopedics 2016; 39:e1011-8. [PMID: 27337666 DOI: 10.3928/01477447-20160616-02] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2015] [Accepted: 08/19/2015] [Indexed: 02/03/2023]
Abstract
Although prosthetic hip dislocation is a common reason for revision arthroplasty, few studies have comprehensively evaluated the radiographic factors that may lead to the need for revision. Therefore, the authors radiographically evaluated all prosthetic hip dislocations that were treated at one institution. They then specifically assessed those that required revision surgery. The authors found that the prosthetic center of rotation (pCOR) was located superolateral and inferolateral to the native COR (nCOR) in all patients. Most hips had pCOR distances more than 5 mm from the nCOR. Furthermore, most patients had cup inclination and anteversion angles within Lewinnek's previously defined "safe zone." Determining these similarities and properly planning these procedures may help decrease the instability rate and therefore improve the overall success of this procedure. [Orthopedics.2016; 39(5):e1011-e1018.].
Collapse
|
486
|
Weber T, Dendorfer S, Bulstra SK, Grifka J, Verkerke GJ, Renkawitz T. Gait six month and one-year after computer assisted Femur First THR vs. conventional THR. Results of a patient- and observer- blinded randomized controlled trial. Gait Posture 2016; 49:418-425. [PMID: 27513739 DOI: 10.1016/j.gaitpost.2016.06.035] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2015] [Revised: 06/22/2016] [Accepted: 06/25/2016] [Indexed: 02/02/2023]
Abstract
A prospective randomized controlled trial is presented that is used to compare gait performance between the computer assisted Femur First (CAS FF) operation method and conventional THR (CON). 60 patients underwent a 3D gait analysis of the lower extremity at pre-operative, 6 months post-operative and twelve months post-operative. Detailed verification experiments were facilitated to ensure the quality of data as well as to avoid over-interpreting of the data. The results confirm a similar data-quality as reported in the literature. Walking speed, range of motion and symmetry thereof improved over the follow-up period, without significant differences between the groups. While all parameters do significantly increase over the follow-up period for both groups, there were no significant differences between them at any given time-point. Patients undergoing CAS FF showed a trend to improved hip flexion angle indicating a possible long-term benefit.
Collapse
Affiliation(s)
- Tim Weber
- Ostbayerische Technische Hochschule Regensburg, Faculty of Mechanical Engineering, Laboratory for Biomechanics, Regensburg, Germany; Regensburg University Medical Center (UKR), Department of Orthopaedic Surgery, Regensburg, Germany.
| | - Sebastian Dendorfer
- Ostbayerische Technische Hochschule Regensburg, Faculty of Mechanical Engineering, Laboratory for Biomechanics, Regensburg, Germany.
| | - Sjoerd K Bulstra
- University of Groningen, University Medical Center Groningen (UMCG), Department of Orthopaedic Surgery, Groningen, The Netherlands.
| | - Joachim Grifka
- Regensburg University Medical Center (UKR), Department of Orthopaedic Surgery, Regensburg, Germany.
| | - Gijsbertus J Verkerke
- University of Groningen, University Medical Center Groningen (UMCG), Department of Rehabilitation Medicine, Groningen, The Netherlands; University of Twente, Department of Biomechanical Engineering, Enschede, The Netherlands.
| | - Tobias Renkawitz
- Regensburg University Medical Center (UKR), Department of Orthopaedic Surgery, Regensburg, Germany.
| |
Collapse
|
487
|
Choi WK, Cho MR, Kim HS, Nam JH, Chae SB. Results of Primary Total Hip Arthroplasty Using 36 mm Femoral Heads on 1st Generation Highly Cross Linked Polyethylene in Patients 50 Years and Less with Minimum Five Year Follow-up. Hip Pelvis 2016; 28:76-81. [PMID: 27536648 PMCID: PMC4972889 DOI: 10.5371/hp.2016.28.2.76] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Revised: 05/04/2016] [Accepted: 05/24/2016] [Indexed: 11/24/2022] Open
Abstract
Purpose We evaluated the clinical and radiographic midterm results of primary total hip arthroplasty (THA) using a 36 mm diameter femoral head on 1st generation highly cross-linked polyethylene (HXLPE) in patients 50 years and less with minimum five year follow-up. Materials and Methods We retrospectively reviewed 31 patients (41 hips) aged 50 years and less underwent primary THA with a 36 mm diameter femoral head on HXLPE between 2004 and 2010. Clinical follow-ups included specific measurements like modified Harris hip scores (HHS) and Merle d'Aubigne and Postel score. For radiologic evaluations, together with position of acetabular cup at six weeks later of postoperation, we separately calculated the penentrations of femoral head into polyethylene liners during postoperation and one year later check-ups, and during one year later check-ups and final check-ups. Results There were no major complications except for one case of dislocation. Average modified HHS at final follow-up was 88 (81-98), and Merle d'Aubigne and Postel scores were more than 15. Mean acetabular cup inclination and anteversion were 45.81°(36.33°-54.91°) and 13.26°(6.72°-27.71°), respectively. Average femoral head penetration of steady-state wear rate determined using radiographs taken at one-year postoperatively and at latest follow-up was 0.042±0.001 mm/year. Conclusion Based on minimum 5 years clinical results, we think 36 mm metal head coupling with HXLPE as the good alternate articulation surface when planning THA for patients aged 50 years and less.
Collapse
Affiliation(s)
- Won-Kee Choi
- Department of Orthopaedic Surgery, Catholic University of Daegu College of Medicine, Daegu, Korea
| | - Myung-Rae Cho
- Department of Orthopaedic Surgery, Catholic University of Daegu College of Medicine, Daegu, Korea
| | - Hee-Soo Kim
- Department of Orthopaedic Surgery, Catholic University of Daegu College of Medicine, Daegu, Korea
| | - Jun-Ho Nam
- Department of Orthopaedic Surgery, Catholic University of Daegu College of Medicine, Daegu, Korea
| | - Seung-Bum Chae
- Department of Orthopaedic Surgery, Catholic University of Daegu College of Medicine, Daegu, Korea
| |
Collapse
|
488
|
Miettinen SSA, Mäkinen TJ, Laaksonen I, Mäkelä K, Huhtala H, Kettunen J, Remes V. Early aseptic loosening of cementless monoblock acetabular components. INTERNATIONAL ORTHOPAEDICS 2016; 41:715-722. [DOI: 10.1007/s00264-016-3254-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2016] [Accepted: 07/19/2016] [Indexed: 10/21/2022]
|
489
|
Inaba Y, Kobayashi N, Suzuki H, Ike H, Kubota S, Saito T. Preoperative planning for implant placement with consideration of pelvic tilt in total hip arthroplasty: postoperative efficacy evaluation. BMC Musculoskelet Disord 2016; 17:280. [PMID: 27412447 PMCID: PMC4944317 DOI: 10.1186/s12891-016-1120-x] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2016] [Accepted: 06/09/2016] [Indexed: 11/13/2022] Open
Abstract
Background In total hip arthroplasty (THA), tilting of the pelvis alters the cup placement angles. Thus, the cup angles need to be planned with consideration of the effects of pelvic tilt. In the present study, we evaluated the efficacy of preoperative planning for implant placement with consideration of pelvic tilt in THA, and the accuracy of a CT-based computer navigation for implant positioning. Methods We examined 75 hips of 75 patients who underwent THA and were followed-up for one year postoperatively. The patients were divided into three groups (anterior, intermediate, posterior tilt) according to their preoperative pelvic tilt. Preoperative planning for implant placement was made with consideration of pelvic tilt and a CT-based navigation was used to execute the preoperative planning. Cup inclination, cup anteversion, and combined anteversion (CA) in supine and standing positions were examined 1 year after THA. The accuracy of the computer navigation was also examined. Results Mean CA was 35.0 ± 5.8° in supine position and 39.3 ± 5.7° in standing position. CA did not differ among the three subgroups (anterior, intermediate, posterior tilt) in either supine or standing position, indicating implant placements to be equally effective. The desired CA (37.3°) was midway between those in supine and standing positions for each subgroup. Respective mean absolute errors between preoperative planning and postoperative CT measurement was 5.3 ± 5.2° for CA. Conclusion We obtained favorable THA results with preoperative planning with consideration of pelvic tilt by demonstrating supine and standing CA to be unaffected by preoperative pelvic tilt one year postoperatively. Mean absolute error of CA between preoperative planning and postoperative measurement was 5° with use of the CT-based navigation.
Collapse
Affiliation(s)
- Yutaka Inaba
- Department of Orthopaedic Surgery, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan.
| | - Naomi Kobayashi
- Department of Orthopaedic Surgery, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan
| | - Haruka Suzuki
- Department of Orthopaedic Surgery, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan
| | - Hiroyuki Ike
- Department of Orthopaedic Surgery, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan
| | - So Kubota
- Department of Orthopaedic Surgery, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan
| | - Tomoyuki Saito
- Department of Orthopaedic Surgery, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan
| |
Collapse
|
490
|
Suda K, Ito T, Miyasaka D, Imai N, Minato I, Endo N. Cup implantation accuracy using the HipCOMPASS mechanical intraoperative support device. SPRINGERPLUS 2016; 5:784. [PMID: 27386270 PMCID: PMC4912536 DOI: 10.1186/s40064-016-2503-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2015] [Accepted: 06/02/2016] [Indexed: 11/23/2022]
Abstract
Background While navigation systems have been developed to increase implantation accuracy in total hip arthroplasty (THA), they are not yet sufficiently versatile or commonly used. Therefore, to elevate the appeal of such systems, we have developed HipCOMPASS, a simple and effective mechanical angle indicator for use in supine THA. Questions/purposes How accurate is the mean cup orientation [in terms of errors in radiographic anteversion (RA) and inclination (RI)] in cases where HipCOMPASS is used for intraoperative support? Does HipCOMPASS increase this cup orientation accuracy compared to THA cases without it? Does HipCOMPASS increase mean operation time? Methods We measured cup orientation in 97 THA cases with HipCOMPASS and in 80 cases without it. Then we compared the angles determined in preoperative planning with the angles revealed by postoperative computed tomography (CT) for both groups. The discrepancy between them was defined as an error. Errors greater than 10° were considered outliers. Additionally, mean operative time with and without the Hip COMPASS were compared. Results With the use of HipCOMPASS, the mean absolute error values in radiographic anteversion and inclination were 2.9° ± 2.3° (range 0°–12.8°) and 2.9° ± 2.1° (0.1°–7.7°), respectively. In contrast, without the use of HipCOMPASS, radiographic anteversion and inclination error values were 8.8° ± 5.8° (0.1°–25.4°) and 6.1° ± 4.5° (0.2°–21.0°), respectively. Outlier occurrence rates were 1.0 % with HipCOMPASS and 48.8 % without it. Mean operative times with and without HipCOMPASS use were 109.2 ± 23.8 min (74–199 min) and 137.6 ± 40.6 min (71–298 min), respectively. Conclusions The study has found that HipCOMPASS dramatically increases implantation accuracy and it is also a simple and highly versatile tool that can be implemented quickly. Given its low cost in addition to its favourable accuracy, simple implementation, and short operative time, HipCOMPASS can be regarded as a very useful and effective THA support device. Level of evidence Retrospective comparative study, Level 3.
Collapse
Affiliation(s)
- Ken Suda
- Department of Orthopedic Surgery, Niigata University, 757 1bancho, Chuoukuasahimatidori, Niigata City, Niigata 951-8510 Japan
| | - Tomoyuki Ito
- Saiseikai Niigatadaini Hospital, 280-7, Nishikuteraji, Niigata City, Niigata 950-1104 Japan
| | - Dai Miyasaka
- Department of Orthopedic Surgery, Niigata University, 757 1bancho, Chuoukuasahimatidori, Niigata City, Niigata 951-8510 Japan
| | - Norio Imai
- Department of Orthopedic Surgery, Niigata University, 757 1bancho, Chuoukuasahimatidori, Niigata City, Niigata 951-8510 Japan
| | - Izumi Minato
- Niigata Rinko Hospital, 114-3 1chome, Higashikumomoyamacho, Niigata City, Niigata 950-8725 Japan
| | - Naoto Endo
- Department of Orthopedic Surgery, Niigata University, 757 1bancho, Chuoukuasahimatidori, Niigata City, Niigata 951-8510 Japan
| |
Collapse
|
491
|
Akiyama K, Nakata K, Kitada M, Yamamura M, Ohori T, Owaki H, Fuji T. Changes in axial alignment of the ipsilateral hip and knee after total hip arthroplasty. Bone Joint J 2016; 98-B:349-58. [PMID: 26920960 DOI: 10.1302/0301-620x.98b3.35468] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
AIMS We investigated changes in the axial alignment of the ipsilateral hip and knee after total hip arthroplasty (THA). PATIENTS AND METHODS We reviewed 152 patients undergoing primary THA (163 hips; 22 hips in men, 141 hips in women) without a pre-operative flexion contracture. The mean age was 64 years (30 to 88). The diagnosis was osteoarthritis (OA) in 151 hips (primary in 18 hips, and secondary to dysplasia in 133) and non-OA in 12 hips. A posterolateral approach with repair of the external rotators was used in 134 hips and an anterior approach in 29 hips. We measured changes in leg length and offset on radiographs, and femoral anteversion, internal rotation of the hip and lateral patellar tilt on CT scans, pre- and post-operatively. RESULTS The mean internal rotation increased by 11° (-15° to 46°) and was associated with underlying disease (OA), pre-operative range of internal rotation, gender, surgical approach, leg lengthening, and change of femoral anteversion (adjusted R(2) : 0.253, p < 0.001). The mean lateral patellar tilt increased by 4° (-5° to 14°) and was associated with age, leg lengthening, and increment of hip internal rotation (adjusted R(2): 0.193, p < 0.001). CONCLUSION Both internal rotation of the hip at rest and lateral patellar tilt are increased after THA. Changes in rotation after THA may affect gait, daily activities, the rate of dislocation of the hip, and ipsilateral knee pain. TAKE HOME MESSAGE Internal rotation of the hip at rest and lateral patellar tilt increase after THA.
Collapse
Affiliation(s)
| | - K Nakata
- Japan Community Healthcare Organization Osaka Hospital, 4-2-78, Fukushima, Fukushima-ku, Osaka, 553-0003, Japan
| | - M Kitada
- Japan Community Healthcare Organization Osaka Hospital, 4-2-78, Fukushima, Fukushima-ku, Osaka, 553-0003, Japan
| | - M Yamamura
- Osaka Rosai Hospital, 1179-3, Nagasone-cho, Kita-ku, Sakai, 591-8025, Japan
| | - T Ohori
- Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita, 565-0871, Japan
| | - H Owaki
- Japan Community Healthcare Organization Osaka Hospital, 4-2-78, Fukushima, Fukushima-ku, Osaka, 553-0003, Japan
| | - T Fuji
- Japan Community Healthcare Organization Osaka Hospital, 4-2-78, Fukushima, Fukushima-ku, Osaka, 553-0003, Japan
| |
Collapse
|
492
|
Woerner M, Weber M, Sendtner E, Springorum R, Worlicek M, Craiovan B, Grifka J, Renkawitz T. Visual intraoperative estimation of range of motion is misleading in minimally invasive total hip arthroplasty. Arch Orthop Trauma Surg 2016; 136:1015-20. [PMID: 27236583 DOI: 10.1007/s00402-016-2478-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2016] [Indexed: 11/24/2022]
Abstract
INTRODUCTION Generally range of motion (ROM) in total hip arthroplasty (THA) is intraoperatively assessed by eye. Can we assume that visual estimation of ROM is reliable? METHODS 60 patients underwent cementless THA in a subgroup analysis of a clinical prospective trial using a minimally invasive anterolateral approach in lateral decubitus position. Four experienced surgeons intraoperatively estimated ROM visually by assessment of the femur relative to the alignment of the patient's pelvis. These estimations were compared with computer navigation measurements. RESULTS We found a mean difference between navigation measurements and intraoperative estimations by eye of -5.6° (±10.9°; -17° to 30°) for flexion, respectively, -0.4° (±10.7°; -24° to 30°) for extension, 8.7° (±9.0°; -10° to 34°) for abduction, 5.9° (±18.3°; -58° to 68°) for external rotation and -5.8° (±12.1°; -38° to 22°) for internal rotation. Multivariate analysis showed no association between the visual accuracy of estimation of ROM and patient characteristics, such as BMI, sex, grade of osteoarthritis and treatment side except for a significant correlation of visual accuracy of estimation of extension and the level of professional experience. Otherwise, the level of professional experience had no impact on the accuracy of estimation of ROM by eye. CONCLUSIONS Even the experienced surgeon's intraoperative estimation of ROM by eye is not reliable and differs up to 30° compared to objective measurements in minimally invasive THA. For accurate intraoperative assessment of ROM, the use of technical devices is recommended. TRIAL REGISTRATION DRKS00000739.
Collapse
Affiliation(s)
- Michael Woerner
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Asklepios Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany.
| | - Markus Weber
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Asklepios Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | - Ernst Sendtner
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Asklepios Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | - Robert Springorum
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Asklepios Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | - Michael Worlicek
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Asklepios Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | - Benjamin Craiovan
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Asklepios Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | - Joachim Grifka
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Asklepios Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | - Tobias Renkawitz
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Asklepios Klinikum Bad Abbach, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| |
Collapse
|
493
|
Hara D, Nakashima Y, Hamai S, Higaki H, Ikebe S, Shimoto T, Yoshimoto K, Iwamoto Y. Dynamic Hip Kinematics During the Golf Swing After Total Hip Arthroplasty. Am J Sports Med 2016; 44:1801-9. [PMID: 27037283 DOI: 10.1177/0363546516637179] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Although most surgeons allow their patients to play golf after total hip arthroplasty (THA), the effect on the implant during the golf swing is still unclear. PURPOSE To evaluate hip kinematics during the golf swing after THA. STUDY DESIGN Descriptive laboratory study. METHODS Eleven hips in 9 patients who underwent primary THA were analyzed. All patients were right-handed recreational golfers, and these 11 hips included 6 right hips and 5 left hips. Periodic radiographic images of the golf swing were taken using a flat-panel x-ray detector. Movements of the hip joint and components were assessed using 3-dimensional-to-2-dimensional model-to-image registration techniques. Liner-to-neck contact and translation of the femoral head with respect to the acetabular cup (cup-head translation) were examined. Hip kinematics, orientation of components, and maximum cup-head translation were compared between patients with and without liner-to-neck contact. RESULTS On average, the golf swing produced approximately 50° of axial rotation in both lead and trail hips. Liner-to-neck contact was observed in 4 hips with elevated rim liners (2 lead hips and 2 trail hips) at maximum external rotation. Neither bone-to-bone nor bone-to-implant contact was observed at any phases of the golf swing in any of the hips. Four hips with liner-to-neck contact had significantly larger maximum external rotation (37.9° ± 7.0° vs 20.6° ± 9.9°, respectively; P = .01) and more cup anteversion (26.5° ± 6.1° vs 10.8° ± 8.9°, respectively; P = .01) than hips without liner-to-neck contact. No significant differences between hips with and without contact were found for cup inclination (42.0° ± 2.5° vs 38.1° ± 5.5°, respectively; P = .22), combined anteversion (45.3° ± 8.9° vs 51.4° ± 7.9°, respectively; P = .26), or maximum cup-head translation (1.3 ± 0.3 mm vs 1.5 ± 0.4 mm, respectively; P = .61). CONCLUSION In this analysis, the golf swing did not produce excessive hip rotation or cup-head translation in any hips. However, liner-to-neck contact during the golf swing was observed in 36% of the hips, with unknown effects on the long-term results. CLINICAL RELEVANCE Golf is an admissible sport after THA because dynamic hip stability was observed. However, the implant position, especially cup anteversion and the use of elevated rim liners, promoted liner-to-neck contact.
Collapse
Affiliation(s)
- Daisuke Hara
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Yasuharu Nakashima
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Satoshi Hamai
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Hidehiko Higaki
- Department of Biorobotics, Faculty of Engineering, Kyushu Sangyo University, Fukuoka, Japan
| | - Satoru Ikebe
- Department of Biorobotics, Faculty of Engineering, Kyushu Sangyo University, Fukuoka, Japan
| | - Takeshi Shimoto
- Department of Information and Systems Engineering, Faculty of Information Engineering, Fukuoka Institute of Technology, Fukuoka, Japan
| | - Kensei Yoshimoto
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Yukihide Iwamoto
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| |
Collapse
|
494
|
Kurosaka K, Fukunishi S, Fukui T, Nishio S, Fujihara Y, Okahisa S, Takeda Y, Daimon T, Yoshiya S. Assessment of Accuracy and Reliability in Acetabular Cup Placement Using an iPhone/iPad System. Orthopedics 2016; 39:e621-6. [PMID: 27322169 DOI: 10.3928/01477447-20160610-05] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2015] [Accepted: 11/30/2015] [Indexed: 02/03/2023]
Abstract
Implant positioning is one of the critical factors that influences postoperative outcome of total hip arthroplasty (THA). Malpositioning of the implant may lead to an increased risk of postoperative complications such as prosthetic impingement, dislocation, restricted range of motion, polyethylene wear, and loosening. In 2012, the intraoperative use of smartphone technology in THA for improved accuracy of acetabular cup placement was reported. The purpose of this study was to examine the accuracy of an iPhone/iPad-guided technique in positioning the acetabular cup in THA compared with the reference values obtained from the image-free navigation system in a cadaveric experiment. Five hips of 5 embalmed whole-body cadavers were used in the study. Seven orthopedic surgeons (4 residents and 3 senior hip surgeons) participated in the study. All of the surgeons examined each of the 5 hips 3 times. The target angle was 38°/19° for operative inclination/anteversion angles, which corresponded to radiographic inclination/anteversion angles of 40°/15°. The simultaneous assessment using the navigation system showed mean±SD radiographic alignment angles of 39.4°±2.6° and 16.4°±2.6° for inclination and anteversion, respectively. Assessment of cup positioning based on Lewinnek's safe zone criteria showed all of the procedures (n=105) achieved acceptable alignment within the safe zone. A comparison of the performances by resident and senior hip surgeons showed no significant difference between the groups (P=.74 for inclination and P=.81 for anteversion). The iPhone/iPad technique examined in this study could achieve acceptable performance in determining cup alignment in THA regardless of the surgeon's expertise. [Orthopedics. 2016; 39(4):e621-e626.].
Collapse
|
495
|
CT-based automated planning of acetabular cup for total hip arthroplasty (THA) based on hybrid use of two statistical atlases. Int J Comput Assist Radiol Surg 2016; 11:2253-2271. [PMID: 27344334 DOI: 10.1007/s11548-016-1428-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2015] [Accepted: 05/27/2016] [Indexed: 10/21/2022]
Abstract
PURPOSE This study describes the use of CT images in atlas-based automated planning methods for acetabular cup implants in total hip arthroplasty (THA). The objective of this study is to develop an automated cup planning method considering the statistical distribution of the residual thickness. METHODS From a number of past THA planning datasets, we construct two statistical atlases that represent the surgeon's expertise. The first atlas is a pelvis-cup merged statistical shape model (PC-SSM), which encodes global spatial relationships between the patient anatomy and implant. The other is a statistical residual thickness map (SRTM) of the implant surface, which encodes local spatial constraints of the anatomy and implant. In addition to PC-SSM and SRTM, we utilized the minimum thickness as a threshold constraint to prevent penetration. RESULTS The proposed method was applied to the pelvis shapes segmented from CT images of 37 datasets of osteoarthritis patients. Automated planning results with manual segmentation were compared to the plans prepared by an experienced surgeon. There was no significant difference in the average cup size error between the two methods (1.1 and 1.2 mm, respectively). The average positional error obtained by the proposed method, which integrates the two atlases, was significantly smaller (3.2 mm) than the previous method, which uses single atlas (3.9 mm). In the proposed method with automated segmentation, the size error of the proposed method for automated segmentation was comparable (1.1 mm) to that for manual segmentation (1.1 mm). The average positional error was significantly worse (4.2 mm) than that using manual segmentation (3.2 mm). If we only consider mildly diseased cases, however, there was no significance between them (3.2 mm in automated and 2.6 mm in manual segmentation). CONCLUSION We infer that integrating PC-SSM and SRTM is a useful approach for modeling experienced surgeon's preference during cup planning.
Collapse
|
496
|
Lash NJ, Whitehouse MR, Greidanus NV, Garbuz DS, Masri BA, Duncan CP. Delayed dislocation following metal-on-polyethylene arthroplasty of the hip due to 'silent' trunnion corrosion. Bone Joint J 2016; 98-B:187-93. [PMID: 26850423 DOI: 10.1302/0301-620x.98b2.36593] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
AIMS We present a case series of ten metal-on-polyethylene total hip arthroplasties (MoP THAs) with delayed dislocation associated with unrecognised adverse local tissue reaction due to corrosion at the trunnion and pseudotumour formation. METHODS The diagnosis was not suspected in nine of the ten patients (six female/four male; mean age 66 years), despite treatment in a specialist unit (mean time from index surgery to revision was 58 months, 36 to 84). It was identified at revision surgery and subsequently confirmed by histological examination of resected tissue. Pre-operative assessment and culture results ruled out infection. A variety of treatment strategies were used, including resection of the pseudotumour and efforts to avoid recurrent dislocation. RESULTS The rate of complications was high and included three deep infections, two patients with recurrent dislocation, and one recurrent pseudotumour. CONCLUSION This series (mean follow-up of 76 months following index procedure and 19 months following revision THA) demonstrates that pseudotumour is an infrequent but important contributor to delayed instability following MoP THA. It is easy to overlook in the differential diagnosis, especially if the alignment of the components is less than optimal, leading to an assumption that malalignment is the cause of the dislocation. The instability is likely to be multifactorial and the revision surgery is complex. TAKE HOME MESSAGE Due to the high complication rate associated with revision in this cohort, the diagnosis should be borne in mind when counselling patients regarding the risks of revision surgery.
Collapse
Affiliation(s)
- N J Lash
- University of British Columbia, 3rd Floor 910 West 10th Avenue, Vancouver, BC, V5Z 4E3, Canada
| | - M R Whitehouse
- University of Bristol, Level 1 Learning and Research Building, Southmead Hospital, Bristol, BS10 5NB, UK
| | - N V Greidanus
- University of British Columbia, 3rd Floor 910 West 10th Avenue, Vancouver, BC, V5Z 4E3, Canada
| | - D S Garbuz
- University of British Columbia, 3rd Floor 910 West 10th Avenue, Vancouver, BC, V5Z 4E3, Canada
| | - B A Masri
- University of British Columbia, 3rd Floor 910 West 10th Avenue, Vancouver, BC, V5Z 4E3, Canada
| | - C P Duncan
- University of British Columbia, 3rd Floor 910 West 10th Avenue, Vancouver, BC, V5Z 4E3, Canada
| |
Collapse
|
497
|
Reikeras O, Gunderson RB. Cross table lateral radiography for measurement of acetabular cup version. ANNALS OF TRANSLATIONAL MEDICINE 2016; 4:169. [PMID: 27275482 DOI: 10.21037/atm.2016.05.08] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Appropriate orientation of the acetabular cup is an important factor for long-term results of total hip arthroplasty. For measurement of cup version cross-table lateral radiography is frequently used, but the reliability has been questioned. We compared cross table lateral radiography with computed tomography in patients that had undergone primary total hip arthroplasty. METHODS The study was prospectively done in 117 patients (117 hips). At 3 months after total hip replacement the acetabular version was measured by cross table lateral radiography and compared to measurements by computed tomography. RESULTS By cross table lateral radiography acetabular anteversion was on mean 13.9° with a standard deviation of 10.1° as compared to 17.8°±12.6° by computed tomography. Mean difference was -3.8 with a distribution of measurements of ±13 degrees for 95% of the cases. CONCLUSIONS Our study shows that cross table radiography provides acceptable information for clinical use, but has limited use for precise analysis of acetabular cup version.
Collapse
Affiliation(s)
- Olav Reikeras
- 1 Department of Orthopedics, 2 Department of Radiology, Oslo University Hospital, Rikshospitalet, Oslo, Norway
| | - Ragnhild Beate Gunderson
- 1 Department of Orthopedics, 2 Department of Radiology, Oslo University Hospital, Rikshospitalet, Oslo, Norway
| |
Collapse
|
498
|
Accuracy of measuring acetabular cup position after total hip arthroplasty: comparison between a radiographic planning software and three-dimensional computed tomography. INTERNATIONAL ORTHOPAEDICS 2016; 41:731-738. [PMID: 27277948 DOI: 10.1007/s00264-016-3240-1] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Accepted: 05/31/2016] [Indexed: 12/26/2022]
Abstract
PURPOSE Various methods are available for measuring acetabular cup position after total hip arthroplasty (THA) on standard anterior-posterior (AP) radiographs. We compared the accuracy of a commercial radiographic planning software program with that of three-dimensional computed tomography (3D-CT) scans. METHODS We obtained plain AP radiographs and 3D-CTs from 65 patients after THA. In addition to calculating cup anteversion and inclination with 3D-CT, we determined the cup position using the radiographic planning software program mediCAD® 2.5 (Hectec, Niederviehbach, Germany). Furthermore, we compared the measurements using the inter-teardrop and bi-ischial lines as pelvic landmarks. RESULTS The mean difference in anteversion between 3D-CT and mediCAD® software was 0.1° using the inter-teardrop line (standard deviation [SD], 8.8°; range, -21° to 23°; p = 0.97) and 0.4° using the bi-ischial line (SD, 8.8°; range, -23° to 21°; p = 0.72). Inclination showed a mean difference of 0.6° using the inter-teardrop line (SD, 4.4°; range, -9° to 21°; p = 0.24) and 0.5° using bi-ischial line (SD, 4.6°; range, -9° to 22°; p = 0.35). The means for absolute differences were 7.2° for anteversion and 3.1° for inclination. With regard to using the bi-ischial or inter-teardrop line, no significant difference was found between the two pelvic landmarks. The intra-class correlation coefficient (ICC) was analysed for anteversion and inclination using either the inter-teardrop line or the bi-ischial line as radiographic baseline. CONCLUSIONS A radiographic planning software program (mediCAD®) is a helpful tool for measuring cup inclination on AP radiographs. With respect to anteversion, measurements are rather susceptible to mistakes with mean inaccuracies of over 7°. Thus, 3D-CT remains the "gold standard" if a lower tolerance limit (±3°) is required for more complex biomechanical evaluations. As a pelvic landmark, the interteardrop line is preferential to the bi-ischial line because of its lower impact on the position of the pelvis.
Collapse
|
499
|
Woerner M, Sendtner E, Springorum R, Craiovan B, Worlicek M, Renkawitz T, Grifka J, Weber M. Visual intraoperative estimation of cup and stem position is not reliable in minimally invasive hip arthroplasty. Acta Orthop 2016; 87:225-30. [PMID: 26848628 PMCID: PMC4900086 DOI: 10.3109/17453674.2015.1137182] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Background and purpose - In hip arthroplasty, acetabular inclination and anteversion-and also femoral stem torsion-are generally assessed by eye intraoperatively. We assessed whether visual estimation of cup and stem position is reliable. Patients and methods - In the course of a subgroup analysis of a prospective clinical trial, 65 patients underwent cementless hip arthroplasty using a minimally invasive anterolateral approach in lateral decubitus position. Altogether, 4 experienced surgeons assessed cup position intraoperatively according to the operative definition by Murray in the anterior pelvic plane and stem torsion in relation to the femoral condylar plane. Inclination, anteversion, and stem torsion were measured blind postoperatively on 3D-CT and compared to intraoperative results. Results - The mean difference between the 3D-CT results and intraoperative estimations by eye was -4.9° (-18 to 8.7) for inclination, 9.7° (-16 to 41) for anteversion, and -7.3° (-34 to 15) for stem torsion. We found an overestimation of > 5° for cup inclination in 32 hips, an overestimation of > 5° for stem torsion in 40 hips, and an underestimation < 5° for cup anteversion in 42 hips. The level of professional experience and patient characteristics had no clinically relevant effect on the accuracy of estimation by eye. Altogether, 46 stems were located outside the native norm of 10-20° as defined by Tönnis, measured on 3D-CT. Interpretation - Even an experienced surgeon's intraoperative estimation of cup and stem position by eye is not reliable compared to 3D-CT in minimally invasive THA. The use of mechanical insertion jigs, intraoperative fluoroscopy, or imageless navigation is recommended for correct implant insertion.
Collapse
|
500
|
Preoperative planning and postoperative evaluation of total hip arthroplasty that takes combined anteversion. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2016; 26:493-500. [PMID: 27154291 PMCID: PMC4911372 DOI: 10.1007/s00590-016-1777-8] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Accepted: 04/27/2016] [Indexed: 11/16/2022]
Abstract
The purpose of this study was to investigate whether postoperative combined anteversion (CA) can be kept within the safe zone while using cementless total hip arthroplasty (THA) using the operative technique which prepares the socket first for developmental dysplasia of the hip (DDH), by estimating the anteversion of the metaphyseal fit stem using preoperative three-dimensional (3D) computerized planning and by adjusting the anteversion of the socket using a navigation system that considers CA. Our subjects were 65 patients (65 hips) that had undergone cementless THA for DDH that could be observed for 1 year or more. Clinical assessments were made using the Japanese Orthopaedic Association’s (JOA) hip score. For a radiological evaluation, we investigated 3D-planned stem versions, postoperative stem versions, preoperative and postoperative CA, and the relationship between CA and dislocation tendencies with temporary intraoperative reductions. JOA hip scores improved from 52.3 ± 11.4 points to 88.9 ± 8.6 points. CT evaluations revealed that 3D-planned stem versions were strongly correlated with postoperative stem versions (r = 0.80; p < 0.01). Preoperative CA was 50.5° ± 7.2°, and postoperative CA was 41.3° ± 8.6°. Postoperative CA was kept within the safe zone in 61 hips. No intraoperative dislocation tendencies were observed in any hips. By estimating the anteversion of the cementless metaphyseal fit stem using 3D planning preoperatively and adjusting the angle of anteversion of the socket using a navigation system that considers CA intraoperatively, postoperative CA can very frequently be kept within the safe zone, even with cementless THA using the operative technique which prepares the socket first for DDH.
Collapse
|