51
|
Namsoy E, Sadikoglu IS, Ozverel CS, Erdag E. Computational analysis of 3D printing: Selecting the better among newly released materials. Eur J Oral Sci 2024; 132:e12987. [PMID: 38616404 DOI: 10.1111/eos.12987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Accepted: 03/27/2024] [Indexed: 04/16/2024]
Abstract
Resin-based three-dimensional (3D) printing finds extensive application in the field of dentistry. Although studies of cytotoxicity, mechanical and physical properties have been conducted for newly released 3D printing resins such as Crowntec (Saremco), Temporary Crown Resin (Formlabs) and Crown & Bridge (Nextdent), the resistance of these materials to esterases in saliva has not been demonstrated at the molecular level. Therefore, in this study, the binding affinities and stability of these new 3D printing resins to the catalytic sites of esterases were investigated using molecular docking and molecular mechanics with Poisson-Bolzmann and surface area solvation (MM/PBSA) methods after active pocket screening. Toxicity predictions of the materials were also performed using ProTox-II and Toxtree servers. The materials were analyzed for mutagenicity, cytotoxicity, and carcinogenicity, and LD50 values were predicted from their molecular structures. The results indicated that out of the three novel 3D printing materials, Nexdent exhibited reduced binding affinity to esterases, indicating enhanced resistance to enzymatic degradation and possessing a superior toxicity profile.
Collapse
Affiliation(s)
- Ege Namsoy
- Department of Endodontics, Faculty of Dentistry, European University of Lefke, Mersin, Turkey
| | - Ismail Serhat Sadikoglu
- Department of Restorative Dentistry, Faculty of Dentistry, Cyprus International University, Nicosia, Cyprus
| | - Cenk Serhan Ozverel
- Department of Basic Medical Sciences, Faculty of Dentistry, Near East University, Nicosia, Cyprus
- DESAM Research Institute, Near East University, Nicosia, Cyprus
| | - Emine Erdag
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Near East University, Nicosia, Cyprus
| |
Collapse
|
52
|
Han JY, Shin JH, Shim JS, Kim RJY. Effects of dentin bonding agents and silanization on bond strength between 3D printed resin and composite resin. Dent Mater J 2024; 43:400-406. [PMID: 38719585 DOI: 10.4012/dmj.2023-181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2024]
Abstract
This study aimed to evaluate the effects of dentin bonding agents and silanization on the bond strength between 3D printed resin and composite resin and compare it with a conventional composite resin. 3D printed resin cylinders (PCB) and composite resin substrates (Z250) were prepared and divided into eight subgroups based on the bonding agents used (n=12). The shear bond strength was measured using a universal testing machine, and the failure modes were evaluated. The bond strength was found to vary significantly among the bonding agents and substrate types. Silane application did not significantly improve the bond strength. Among the bonding agents, the universal adhesives exhibited the highest bond strengths for both substrates. Compared to PCB, Z250 demonstrated stronger bonds and exhibited more cohesive failures. Further research is needed to optimize the surface treatments and resin formulations for enhanced bond strength and durability between 3D printed and composite resins.
Collapse
Affiliation(s)
- Jae-Yeon Han
- Department of Conservative Dentistry, Korea University Medical Center Guro Hospital
| | - Joo-Hee Shin
- Department of Conservative Dentistry, Korea University Medical Center Guro Hospital
| | - Ji-Suk Shim
- Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Guro Hospital
| | - Ryan Jin Young Kim
- Department of Dental Science, Dental Research Institute, School of Dentistry, Seoul National University
| |
Collapse
|
53
|
Oyar P, Ulusoy M. Effect of milling procedures in CAD-CAM systems on the color changes of CAD-CAM polymethyl methacrylate resin material as interim material. BMC Oral Health 2024; 24:618. [PMID: 38807102 PMCID: PMC11131249 DOI: 10.1186/s12903-024-04350-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Accepted: 05/08/2024] [Indexed: 05/30/2024] Open
Abstract
PURPOSE This study aimed to investigate the effects of new and used burs on CAD-CAM PMMA resin color changes following thermocycling. MATERIALS AND METHODS Twenty disk-shaped specimens (10 × 2 mm) were made using a single brand of CAD-CAM polymethyl methacrylate resin (Polident) for the color test. Group N consisted of half of the specimens that were machined using the new tungsten carbide bur set, and Group U consisted of the specimens that were milled using the used bur set (500 machining time). A color test was performed on the specimens both before and after thermocycling. For the statistical analysis, the Kruskal-Wallis and Dunn Pairwise Comparison tests were employed. RESULTS The ∆E* value of specimens (2.057) milled with the used bur was higher than those of specimens milled with the new bur (0.340), but this value is within clinically acceptable limits. After thermocycling, specimens milled with the utilized burs had the greatest L* (93.850) and b* (5.000) values. After thermocycling, statistically significant differences were discovered between Group N and Group U as well as between specimens milled with the utilized bur before and after thermocycling. CONCLUSION Thermocycling process have an effect on the mean ∆E values of specimens milled with the used carbide bur, but these ∆E* values were not statistically significant. CLINICAL SIGNIFICANCE The color and clinical performance of CAD-CAM restorations may be affected by variations in CAD-CAM milling bur properties, particularly those related to their frequent use.
Collapse
Affiliation(s)
- Perihan Oyar
- Department of Dental Prostheses Technology, Health Services Vocational High School, Hacettepe University, D Block, 3. Floor, Sihhiye, 06100, Ankara, Turkey.
| | - Mutahhar Ulusoy
- Department of Prosthodontics, Faculty of Dentistry, Near East University, Mersin, 10, Turkey
| |
Collapse
|
54
|
Nagai T, Alfaraj A, Chu TMG, Yang CC, Lin WS. Color stability of CAD-CAM hybrid ceramic materials following immersion in artificial saliva and wine. J Prosthodont 2024. [PMID: 38742795 DOI: 10.1111/jopr.13868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 04/21/2024] [Indexed: 05/16/2024] Open
Abstract
PURPOSE To examine the color stability of 3D-printed and milled, interim, and definitive, restorative materials after immersion in artificial saliva and wine for 1, 3, and 6 months. MATERIAL AND METHODS The study used a 2 × 5 factorial design with 10 subgroups, including 2 immersion liquids (artificial saliva and wine) and 5 manufacturing technology and restorative material combinations (n = 10). Color measurements were taken using a contact-type digital spectrophotometer (CM-2600d Spectrophotometer; Konica Minolta Healthcare Americas Inc) before immersion and at 1 month (T1), 3 months (T3), and 6 months (T6) after immersion. The CIE2000 system was used to calculate quantitative measurements of color differences in ΔE00, and comparisons were made to the acceptability threshold (AT) and perceptibility threshold (PT). Repeated measures of ANOVA (α = 0.05) were used to compare differences in color changes between manufacturing technology/restorative material-immersion liquid combinations at T1, T3, and T6. RESULTS To compare the effect of immersion liquid and time on the manufacturing technology/restorative material groups, the ΔE00 values were compared to the PT of 0.8 and the AT of 1.8. Wine caused significant color changes in ΔE00 values beyond the PT and AT values in all groups at all time intervals, except for the AT value of milled definitive crowns (hybrid nano-ceramic material). Wine immersion caused significant ΔE00 for all manufacturing technology/restorative material groups at all time intervals (1 month, 3 months, and 6 months) when compared to artificial saliva immersion (all p < 0.001). CONCLUSION Upon exposure to artificial saliva, 80%-100% of samples from all groups remained within the acceptable and perceptible color change thresholds. The wine had significant chromogenic effects on all tested restorative materials, however, the milled definitive crowns (hybrid nano-ceramic material) showed the greatest color stability. For patients with heavy wine consumption, 3D-printed definitive crowns (hybrid ceramic-filled material) may show discoloration exceeding acceptable and perceptible color change limits.
Collapse
Affiliation(s)
- Toshiki Nagai
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| | - Amal Alfaraj
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA
- Department of Prosthodontics, King Faisal University, School of Dentistry, Al Ahsa, Saudi Arabia
| | - Tien-Min G Chu
- Department of Biomedical Sciences and Comprehensive Care, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| | - Chao-Chieh Yang
- Advanced Education Program in Prosthodontics, Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| | - Wei-Shao Lin
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| |
Collapse
|
55
|
Nowicki A, Osypko K, Kurzawa A, Roszak M, Krawiec K, Pyka D. Mechanical and Material Analysis of 3D-Printed Temporary Materials for Implant Reconstructions-A Pilot Study. Biomedicines 2024; 12:870. [PMID: 38672224 PMCID: PMC11048395 DOI: 10.3390/biomedicines12040870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Revised: 04/09/2024] [Accepted: 04/11/2024] [Indexed: 04/28/2024] Open
Abstract
In this study, the authors analyzed modern resin materials typically used for temporary reconstructions on implants and manufactured via 3D printing. Three broadly used resins: NextDent Denture 3D, NextDent C&B MFH Bleach, and Graphy TC-80DP were selected for analysis and compared to currently used acrylic materials and ABS-like resin. In order to achieve this, mechanical tests were conducted, starting with the static tensile test PN-EN. After the mechanical tests, analysis of the chemical composition was performed and images of the SEM microstructure were taken. Moreover, numerical simulations were conducted to create numerical models of materials and compare the accuracy with the tensile test. The parameters obtained in the computational environment enabled more than 98% correspondence between numerical and experimental charts, which constitutes an important step towards the further development of numeric methods in dentistry and prosthodontics.
Collapse
Affiliation(s)
- Adam Nowicki
- Diamante Dental Clinic, ul. Sportowa 48A/C, 59-300 Lubin, Poland;
| | - Karolina Osypko
- Dental Salon, Oral Surgery Academy, ul. E. Horbaczewskiego 53A, 54-130 Wroclaw, Poland
| | - Adam Kurzawa
- Department of Lightweight Elements Engineering, Foundry and Automation, Faculty of Mechanical Engineering, Wroclaw University of Science and Technology, Smoluchowskiego 25, 50-370 Wroclaw, Poland;
| | - Maciej Roszak
- Department of Mechanics, Materials Science and Biomedical Engineering, Wrocław University of Science and Technology, Smoluchowskiego 25, 50-370 Wroclaw, Poland; (M.R.); (K.K.); (D.P.)
| | - Karina Krawiec
- Department of Mechanics, Materials Science and Biomedical Engineering, Wrocław University of Science and Technology, Smoluchowskiego 25, 50-370 Wroclaw, Poland; (M.R.); (K.K.); (D.P.)
| | - Dariusz Pyka
- Department of Mechanics, Materials Science and Biomedical Engineering, Wrocław University of Science and Technology, Smoluchowskiego 25, 50-370 Wroclaw, Poland; (M.R.); (K.K.); (D.P.)
| |
Collapse
|
56
|
Espinar C, Pérez MM, Pulgar R, Leon-Cecilla A, López-López MT, Della Bona A. Influence of printing orientation on mechanical properties of aged 3D-printed restorative resins. Dent Mater 2024; 40:756-763. [PMID: 38429216 DOI: 10.1016/j.dental.2024.02.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 02/15/2024] [Accepted: 02/18/2024] [Indexed: 03/03/2024]
Abstract
OBJECTIVE To evaluate the influence of printing orientation on flexural strength (σf) and elastic modulus (E) of different 3D printing dental restorative resins. METHODS Bar-shaped specimens (n = 20) were fabricated from two SLA-printed resins (FT- Formlabs Temporary, and FP- Formlabs Permanent) and two DLP-printed resins (DFT- Detax Freeprint Temp, and GCT- GC Temporary) using two building orientations (0º and 90º). The 3D-printed structures were aged (14 d) before submitted to three-point bending in 37ºC distilled water at a crosshead speed of 1.0 ± 0.3 mm/min until fracture to calculate the σf and the E values. The fractured surfaces were evaluated using stereomicroscopy and scanning electron microscopy (SEM) following fractography principles. Data were statistically analyzed using two-way ANOVA and Tukey post-hoc (α = 0.001). RESULTS FP and FT showed significantly higher E values than DFT and GCT, irrespectively of printing orientation (p < 0.001). There was no statistical difference between the building orientations (0º and 90º) for the mean σf and E values for the resin materials evaluated. Fractographic characteristics were similar for the surface fracture from all the materials evaluated, showing typical brittle fracture behavior. SIGNIFICANCE Printing orientation did not influence of flexural strength and elastic modulus values for the 3D-printed resin structures evaluated. Surface topography was mostly governed by the 3D printer type.
Collapse
Affiliation(s)
- Cristina Espinar
- Department of Stomatology, Faculty of Dentistry, Colegio Máximo, Campus de Cartuja s/n. University of Granada, 18071 Granada, Spain
| | - María M Pérez
- Department of Optics, Faculty of Science, Campus Fuentenueva, Edificio Mecenas, s/n. University of Granada, 18071 Granada, Spain
| | - Rosa Pulgar
- Department of Stomatology, Faculty of Dentistry, Colegio Máximo, Campus de Cartuja s/n. University of Granada, 18071 Granada, Spain
| | - Alberto Leon-Cecilla
- Department of Applied physics, Faculty of Science, Campus Fuentenueva, University of Granada, 18071 Granada, Spain
| | - Modesto T López-López
- Department of Applied physics, Faculty of Science, Campus Fuentenueva, University of Granada, 18071 Granada, Spain
| | - Alvaro Della Bona
- Postgraduate Program in Dentistry, Dental School, University of Passo Fundo, Campus I, Passo Fundo, RS, Brazil.
| |
Collapse
|
57
|
Toksoy D, Önöral Ö. Influence of glazing and aging on the marginal, axial, axio-occlusal, and occlusal fit of 3-unit monolithic zirconia restorations fabricated using additive and subtractive techniques. J Prosthet Dent 2024; 131:658.e1-658.e9. [PMID: 38342643 DOI: 10.1016/j.prosdent.2024.01.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 01/08/2024] [Accepted: 01/10/2024] [Indexed: 02/13/2024]
Abstract
STATEMENT OF PROBLEM Studies are sparse on how glazing and aging influence the fit of additively fabricated monolithic zirconia restorations. PURPOSE The purpose of this in vitro study was to assess the effect of glazing and aging on the fit of 3-unit monolithic zirconia restorations fabricated using different techniques. MATERIAL AND METHODS A total of 32 monolithic zirconia restorations were fabricated for a typodont model by using 4 distinct techniques (subtractive fabrication [SF], stereolithography [SLA], digital light processing [DLP], and lithography-based ceramic manufacturing [LCM]). The silicone replica approach was adopted to measure the discrepancy values for premolar and molar abutments after sintering, glazing, and 1 year of aging. The silicone replicas were sliced into mesiodistal and buccopalatal cross-sections, and digital micrographs of the cross-sections were made with a ×80 stereomicroscope. An inherent measuring program was run to record the discrepancy values (µm). Repeated-measures 2-way ANOVAs with the Bonferroni post hoc test were used to statistically analyze the acquired data. (α=.05). RESULTS From the repeated measures 2-way ANOVAs, both the glazing×fabrication technique and the aging×fabrication technique interactions were not statistically significant (P>.05). Glazing significantly influenced premolar abutment marginal (P=.022) and occlusal (P=.007) discrepancy values, as well as molar abutment marginal discrepancy values (P=.047). Aging had a statistically significant effect on premolar abutment marginal (P=.008) and occlusal (P=.011) discrepancy values, as well as molar abutment occlusal discrepancy values (P=.039). In both the glazing and aging data, for all areas of interest, statistically significant differences were detected among the fabrication techniques (P<.05). The LCM group had the lowest discrepancy values, followed by the SLA, SF, and DLP groups. CONCLUSIONS The LCM and SLA groups outperformed the other groups in terms of fit accuracy. The glazing and aging procedures altered the discrepancy values. The marginal discrepancy values of all groups were below the threshold of clinical acceptability (<120 µm).
Collapse
Affiliation(s)
- Dilem Toksoy
- Research Assistant, Department of Prosthetic Dentistry, Faculty of Dentistry, Near East University, Nicosia, North Cyprus
| | - Özay Önöral
- Associate Professor, Department of Prosthetic Dentistry, Faculty of Dentistry, Near East University, Nicosia, North Cyprus.
| |
Collapse
|
58
|
Poltorak M, Banatkiewicz P, Poltorak L, Sobolewski P, Zimon D, Szwast M, Walecka I. Brachytherapy and 3D printing for skin cancer: A review paper. J Contemp Brachytherapy 2024; 16:156-169. [PMID: 38808207 PMCID: PMC11129648 DOI: 10.5114/jcb.2024.137357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 02/23/2024] [Indexed: 05/30/2024] Open
Abstract
Brachytherapy is a type of radiation therapy, in which a radiation source is placed directly or close to a tumor. It is commonly used to treat skin cancer, and enables precise irradiation treatment of affected area (planning target volume - PTV) while minimizing exposure dose to surrounding healthy tissue (organs at risk - OARs). Recently, the use of 3D printing has begun revolutionizing brachytherapy, as it allows manufacturing of custom-designed applicators for unique shape of skin topography, tumor, and surrounding tissues. Outcome of the combination of 3D printing and brachytherapy has several advantages over traditional treatment planning methods. Some of the advantages are intuitive, whereas others can be concluded from a literature overview as follows: 1) Possibility of developing patient-specific applicators that precisely match the shape of tumor area; 2) Reduction of the time required for applicator production, especially when custom-made devices are needed; 3) Reduction of manufacturing costs; 4) Treatment procedures improvement; 5) Improvement of safety measures accelerated by the development of smart materials (e.g., polymer filaments with admixture of heavy elements); 6) Possibility of nearly instant adjustment into tumor treatment (applicators can be changed as the tumor is changing its shape); and 7) Applicators designed to securely fit to treatment area to hold radioactive source always in the same place for each fraction. Consequently, tumor-provided dose is accurate and leads to effective treatment. In this review paper, we investigated the current state-of-the-art of the application of 3D printing in brachytherapy. A number of existing reports were chosen and reviewed in terms of printing technology, materials used, treatment effectiveness, and fabrication protocols. Furthermore, the development of future directions that should be considered by collaborative teams bridging different fields of science, such as medicine, physics, chemistry, and material science were summarized. With the indicated topics, we hope to stimulate the innovative progress of 3D printing technology in brachytherapy.
Collapse
Affiliation(s)
- Michal Poltorak
- The National Institute of Medicine of the Ministry of the Interior and Administration, Warsaw, Poland
| | - Pawel Banatkiewicz
- The National Institute of Medicine of the Ministry of the Interior and Administration, Warsaw, Poland
| | - Lukasz Poltorak
- Electrochemistry@Soft Interfaces Team, Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, Lodz, Poland
| | - Piotr Sobolewski
- The National Institute of Medicine of the Ministry of the Interior and Administration, Warsaw, Poland
- Department of Dermatology, Centre of Postgraduate Medical Education, Warsaw, Poland
| | - Damian Zimon
- The National Institute of Medicine of the Ministry of the Interior and Administration, Warsaw, Poland
- Department of Dermatology, Centre of Postgraduate Medical Education, Warsaw, Poland
| | - Maciej Szwast
- Department of Chemical and Process Engineering, Warsaw University of Technology, Warsaw, Poland
| | - Irena Walecka
- The National Institute of Medicine of the Ministry of the Interior and Administration, Warsaw, Poland
- Department of Dermatology, Centre of Postgraduate Medical Education, Warsaw, Poland
| |
Collapse
|
59
|
Radwan M, Abdou A, Tawfik A, Bills P, Blunt L, Kusumasari C, Mahrous A. Trueness of vat-photopolymerization printing technology of interim fixed partial denture with different building orientation: A Microcomputed tomography study. J Clin Exp Dent 2024; 16:e494-e502. [PMID: 38725814 PMCID: PMC11078504 DOI: 10.4317/jced.61422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Accepted: 03/04/2024] [Indexed: 05/12/2024] Open
Abstract
Background The aim was to assess the consequence of different printing orientation on the marginal misfit and internal gap of 3-unit interim fixed partial denture manufactured by two different additive manufacturing technologies compared to milling technique. Material and Methods Three-unit interim fixed partial denture (FPD) was designed by using exocad software (Dental CAD 3.0 Galway) in the format of standard tessellation language (STL) , which was transferred to a nesting software (PreForm) and printed by A Next Dent C&B resin liquid (NextDent; Soesterberg, Neitherland) by using two printing technologies; stereolithography (SLA, n=30) and digital light processing (DLP, n=30) with 3 different orientations (occlusal direction [0°] ,buccal direction [90°] & lingual direction [270°]) for each technology (n=10). Additionally, a control group was milled (CAD/Milling, n=10) from DC PMMA A1 Disc (White peaks dental solutions; Gmbh& co., Germany). A Microcomputed tomography was used to measure the marginal misfit and internal gap for each specimen in 12 different points. The average value of the marginal and internal gaps measurements was calculated, and one-way ANOVA was used for the comparison between groups. Results SLA printing technology showed a similar result to CAD/Milling with all different printing orientations tested. DLP printing technology showed the highest gap values within all the printing orientations with significant difference (p< 0.001) with the CAD/Milling and SLA. Conclusions Regarding the trueness of the interim FPDs, SLA was a promising technology for its superior adaptation. Marginal misfit and Internal gap for DLP printing technology limiting the use of that technology as it exceeded the acceptable clinical range. Key words:3D Printing, Microcomputed topography, Marginal Gap, Internal Misfit.
Collapse
Affiliation(s)
- Mohamed Radwan
- Fixed Prosthodontics Department, Faculty of Dentistry, Bani-Suef University, Bani-Suef, Egypt
| | - Ahmed Abdou
- Faculty of Dentistry, Al-Ayen Iraq University, Thi-Qar, Iraq
| | - Ahmed Tawfik
- EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, United Kingdom
| | - Paul Bills
- EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, United Kingdom
| | - Liam Blunt
- EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, United Kingdom
| | - Citra Kusumasari
- Department of Conservative Dentistry, Faculty of Dentistry, Universitas Indonesia, Jakarta, Indonesia
| | - Aliaa Mahrous
- Fixed Prosthodontics Department, Faculty of Dentistry, Fayoum University, Fayoum,and October University for Modern Sciences and Art, 6th of October City, Egypt
| |
Collapse
|
60
|
Khiari Z. Recent Developments in Bio-Ink Formulations Using Marine-Derived Biomaterials for Three-Dimensional (3D) Bioprinting. Mar Drugs 2024; 22:134. [PMID: 38535475 PMCID: PMC10971850 DOI: 10.3390/md22030134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 03/12/2024] [Accepted: 03/13/2024] [Indexed: 05/01/2024] Open
Abstract
3D bioprinting is a disruptive, computer-aided, and additive manufacturing technology that allows the obtention, layer-by-layer, of 3D complex structures. This technology is believed to offer tremendous opportunities in several fields including biomedical, pharmaceutical, and food industries. Several bioprinting processes and bio-ink materials have emerged recently. However, there is still a pressing need to develop low-cost sustainable bio-ink materials with superior qualities (excellent mechanical, viscoelastic and thermal properties, biocompatibility, and biodegradability). Marine-derived biomaterials, including polysaccharides and proteins, represent a viable and renewable source for bio-ink formulations. Therefore, the focus of this review centers around the use of marine-derived biomaterials in the formulations of bio-ink. It starts with a general overview of 3D bioprinting processes followed by a description of the most commonly used marine-derived biomaterials for 3D bioprinting, with a special attention paid to chitosan, glycosaminoglycans, alginate, carrageenan, collagen, and gelatin. The challenges facing the application of marine-derived biomaterials in 3D bioprinting within the biomedical and pharmaceutical fields along with future directions are also discussed.
Collapse
Affiliation(s)
- Zied Khiari
- National Research Council of Canada, Aquatic and Crop Resource Development Research Centre, 1411 Oxford Street, Halifax, NS B3H 3Z1, Canada
| |
Collapse
|
61
|
Palaszkó D, Németh A, Török G, Vecsei B, Vánkos B, Dinya E, Borbély J, Marada G, Hermann P, Kispélyi B. Trueness of five different 3D printing systems including budget- and professional-grade printers: An In vitro study. Heliyon 2024; 10:e26874. [PMID: 38468926 PMCID: PMC10925989 DOI: 10.1016/j.heliyon.2024.e26874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 02/20/2024] [Accepted: 02/21/2024] [Indexed: 03/13/2024] Open
Abstract
Problem Several types of 3D printers with different techniques and prices are available on the market. However, results in the literature are inconsistent, and there is no comprehensive agreement on the accuracy of 3D printers of different price categories for dental applications. Aim This study aimed to investigate the accuracy of five different 3D printing systems, including a comparison of budget- and higher-end 3D printing systems, according to a standardized production and evaluation protocol. Material and methods A maxillary reference model with prepared teeth was created using 16 half-ball markers with a diameter of 1 mm to facilitate measurements. A reference file was fabricated using five different 3D printers. The printed models were scanned and superimposed onto the original standard tesselation language (.stl) file, and digital measurements were performed to assess the 3-dimensional and linear deviations between the reference and test models. Results After examining the entire surface of the models, we found that 3D printers using Fused filament fabrication (FFF) technology -120.2 (20.3) μm create models with high trueness but high distortion. Distortions along the z-axis were found to be the highest with the stereolithography (SLA)-type 3D printer at -153.7 (38.7) μm. For the 4-unit FPD, we found 201.9 (41.8) μm deviation with the digital light processing (DLP) printer. The largest deviation (-265.1 (55.4) μm) between the second molars was observed for the DLP printer. Between the incisor and the second molar, the best results were produced by the FFF printer with -30.5 (76.7) μm. Conclusion Budget-friendly 3D printers are comparable to professional-grade printers in terms of precision. In general, the cost of a printing system is not a reliable indicator of its level of accuracy.
Collapse
Affiliation(s)
- Dénes Palaszkó
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Anna Németh
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Gréta Török
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Bálint Vecsei
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Boldizsár Vánkos
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Elek Dinya
- Institute of Digital Health Sciences, Semmelweis University, Budapest, Hungary
| | - Judit Borbély
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | | | - Péter Hermann
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Barbara Kispélyi
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| |
Collapse
|
62
|
Güntekin N, Tunçdemir AR. Comparison of volumetric loss and surface roughness of composite dental restorations obtained by additive and subtractive manufacturing methods. Heliyon 2024; 10:e26269. [PMID: 38390076 PMCID: PMC10882017 DOI: 10.1016/j.heliyon.2024.e26269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 02/05/2024] [Accepted: 02/09/2024] [Indexed: 02/24/2024] Open
Abstract
Statement of problem Permanent crown materials produced with new generation additive manufacturing and traditional subtractive manufacturing materials have not been compared in terms of wear resistance. Purpose This study aims to compare the volumetric loss related to wear and resulting surface roughness after aging in a chewing simulator between resin nano ceramics produced with milling technique and permanent crown materials produced with three dimensional (3D) printing. Materials and methods Three different hybrid composite-ceramic (HCC) (The three materials are GC: Cerasmart, VE: Vita Enamic, and GV: Grandio Voco.) and one 3D printed definitive crown resin (FormLabs Permanent Crown Resin) were investigated before aging (n:8), the surface roughness of all samples was measured with a profilometer, and 1 randomly selected sample from each subgroup was imaged with scanning electron microscope (SEM). 3D scans of each sample were obtained with a desktop scanner. Thermomechanical aging was performed using a chewing simulator. Four hundred thousand cycles were completed under a vertical occlusal force of 49 ± 0.7 N with a thermal cycle of 1.7 Hz 5-55° and with a dwell time of 120 s, mimicking 2 years of aging. The imaging procedures were repeated, and the change in surface roughness was evaluated. 3D images were also overlapped, and the volumetric loss was calculated with the relevant inspector software. The data obtained were analyzed by two-way ANOVA (p < 0.05). Result The results showed significant statistical differences for both parameters (p > 0.05). The highest volumetric loss was found in the GV group while the lowest volumetric loss was in the VE group. The highest surface roughness values were observed in the GV group, while the lowest values belonged to the VE one. Conclusion Of the restorative materials evaluated, the VE group is suitable for long-term restorations, whereas the GV one is suitable for medium-term restorations. It is promising in terms of 3D printing technologies that the 3D material gives comparable results with the GV group. Clinical i̇mplication Additive manufacturing techniques are a successful method that accelerates the manufacturing process. Permanent crown resins are promising alternatives to conventional production.
Collapse
Affiliation(s)
- Neslihan Güntekin
- Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey
| | - Ali Rıza Tunçdemir
- Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey
| |
Collapse
|
63
|
Caussin E, Moussally C, Le Goff S, Fasham T, Troizier-Cheyne M, Tapie L, Dursun E, Attal JP, François P. Vat Photopolymerization 3D Printing in Dentistry: A Comprehensive Review of Actual Popular Technologies. MATERIALS (BASEL, SWITZERLAND) 2024; 17:950. [PMID: 38399200 PMCID: PMC10890271 DOI: 10.3390/ma17040950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Revised: 02/09/2024] [Accepted: 02/13/2024] [Indexed: 02/25/2024]
Abstract
In this comprehensive review, the current state of the art and recent advances in 3D printing in dentistry are explored. This article provides an overview of the fundamental principles of 3D printing with a focus on vat photopolymerization (VP), the most commonly used technological principle in dental practice, which includes SLA, DLP, and LCD (or mSLA) technologies. The advantages, disadvantages, and shortcomings of these technologies are also discussed. This article delves into the key stages of the dental 3D printing process, from computer-aided design (CAD) to postprocessing, emphasizing the importance of postrinsing and postcuring to ensure the biocompatibility of custom-made medical devices. Legal considerations and regulatory obligations related to the production of custom medical devices through 3D printing are also addressed. This article serves as a valuable resource for dental practitioners, researchers, and health care professionals interested in applying this innovative technology in clinical practice.
Collapse
Affiliation(s)
- Elisa Caussin
- Faculty of Dental Surgery, University of Paris Cité, 75006 Paris, France
- Bretonneau Hospital, Assistance Publique des Hôpitaux de Paris (AP-HP), 75018 Paris, France
- Université of Paris Cité, URB2i, 92100 Montrouge, France
| | | | - Stéphane Le Goff
- Faculty of Dental Surgery, University of Paris Cité, 75006 Paris, France
- Université of Paris Cité, URB2i, 92100 Montrouge, France
| | - Timothy Fasham
- Faculty of Dental Surgery, University of Paris Cité, 75006 Paris, France
- Bretonneau Hospital, Assistance Publique des Hôpitaux de Paris (AP-HP), 75018 Paris, France
- Université of Paris Cité, URB2i, 92100 Montrouge, France
| | - Max Troizier-Cheyne
- Faculty of Dental Surgery, University of Paris Cité, 75006 Paris, France
- Bretonneau Hospital, Assistance Publique des Hôpitaux de Paris (AP-HP), 75018 Paris, France
- Université of Paris Cité, URB2i, 92100 Montrouge, France
| | - Laurent Tapie
- Faculty of Dental Surgery, University of Paris Cité, 75006 Paris, France
- Université of Paris Cité, URB2i, 92100 Montrouge, France
- EPF École d’Ingénieurs, 94230 Cachan, France
| | - Elisabeth Dursun
- Faculty of Dental Surgery, University of Paris Cité, 75006 Paris, France
- Université of Paris Cité, URB2i, 92100 Montrouge, France
- Henri Mondor Hospital, AP-HP, 94000 Créteil, France
| | - Jean-Pierre Attal
- Faculty of Dental Surgery, University of Paris Cité, 75006 Paris, France
- Université of Paris Cité, URB2i, 92100 Montrouge, France
- Charles Foix Hospital, AP-HP, 94200 Ivry-Sur-Seine, France
| | - Philippe François
- Faculty of Dental Surgery, University of Paris Cité, 75006 Paris, France
- Bretonneau Hospital, Assistance Publique des Hôpitaux de Paris (AP-HP), 75018 Paris, France
- Université of Paris Cité, URB2i, 92100 Montrouge, France
| |
Collapse
|
64
|
de Souza FA, Blois MC, Collares K, Dos Santos MBF. 3D-printed and conventional provisional single crown fabrication on anterior implants: A randomized clinical trial. Dent Mater 2024; 40:340-347. [PMID: 38103959 DOI: 10.1016/j.dental.2023.12.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 11/28/2023] [Accepted: 12/08/2023] [Indexed: 12/19/2023]
Abstract
OBJECTIVES The present study aims to compare provisional single crowns on anterior implants made using conventional PMMA and 3D-printed workflows. The study assessed the occurrence of failures, color variation, signs of early deterioration, operating time, and patients' satisfaction with the treatment through a randomized controlled trial. METHODS This study was conducted as a randomized controlled trial, following the SPIRIT and CONSORT guidelines. Patients were included in the study after meeting the eligibility criteria and were randomly assigned to one of two groups (conventional and 3D-printed). FDI criteria, visible plaque index (VPI), bleeding on probing (BOP), and color variation were considered as the primary outcomes. Operating time and patient satisfaction were also assessed as secondary outcomes. Fisher's exact test was performed to analyze the association between the primary and secondary outcomes and the study groups. Mann-Whitney test was used to compare the mean VAS satisfaction scores between the conventional PMMA and 3D-printed groups (STATA 14™, with an α = 0.05). RESULTS A total of 42 provisional single crowns (n = 21) were made for 33 patients. Only the fracture parameter (FDI) showed a statistically significant difference, with 3D-printed provisionals exhibiting higher rates of catastrophic failures compared to conventional ones (p = 0.05). Although the operating time for the 3D-printed group was shorter (p < 0.001), no statistical difference observed in patients' satisfaction regarding esthetics, phonetics, chewing, or comfort. SIGNIFICANCE 3D-printed and conventional PMMA provisional single crowns showed comparable clinical performance, except for the observed fracture types. Although 3D-printed provisional restorations showed a shorter operating time, overall patients' satisfaction was not affected.
Collapse
Affiliation(s)
- Fernanda Angeloni de Souza
- Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil; Program in Dentistry, Mercosur Dental Educational Institute, Brazil
| | - Matheus Coelho Blois
- Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil; Program in Dentistry, Mercosur Dental Educational Institute, Brazil
| | - Kaue Collares
- Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| | | |
Collapse
|
65
|
Lee JM, Son K, Lee KB. Evaluation of photopolymer resins for dental prosthetics fabricated via the stereolithography process at different polymerization temperatures. Part II: Dimensional accuracy and fracture load of fixed dental prostheses. J Prosthet Dent 2024; 131:330.e1-330.e9. [PMID: 37993321 DOI: 10.1016/j.prosdent.2023.10.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 10/19/2023] [Accepted: 10/20/2023] [Indexed: 11/24/2023]
Abstract
STATEMENT OF PROBLEM Prostheses printed on a 3-dimensional (3D) printer need to undergo the postpolymerization process, which can increase the working time. However, it has been not suggested for reducing workload and improving the properties of prostheses in dental clinical practice. PURPOSE The purpose of this in vitro study was to evaluate how the printing temperature impacts the dimensional accuracy and fracture load of 3D printed fixed dental prostheses (FDPs). MATERIAL AND METHODS Dental prostheses were printed at room temperature (RT), 50°C, and 70°C using a stereolithography 3D printer. Subsequently, after rinsing away residual monomer, the printed parts underwent the green condition (it was not subjected to any postprocessing) and postpolymerization. The mechanical properties of the printed FDPs were determined by loading to fracture (n=6). To evaluate their clinical applicability, the dimensional accuracy and fit of FDPs fabricated at various resin polymerization temperatures were measured (n=6). The 1-way analysis of variance was used to perform statistical comparisons, followed by the Tukey honestly significant difference test (α=.05). RESULTS The specimens printed at RT and 50°C were better than those printed at 70°C in terms of dimensional accuracy and fit (P<.05). Nonetheless, the dimensional accuracy and fit of the specimens printed at 70°C were clinically acceptable. The fracture load of the 3-unit FDPs depended significantly on the printing temperature. CONCLUSIONS The dimensional accuracy and fracture load of the 70°C group were acceptable for FDP fabrication. Thus, the temperature of 70°C without postprocessing may help make the procedure more efficient.
Collapse
Affiliation(s)
- Ji-Min Lee
- Graduate student, Advanced Dental Device Development Institute, Department of Dental Science, Graduate School, Kyungpook National University, Daegu, Republic of Korea
| | - KeunBaDa Son
- Research Professor, Advanced Dental Device Development Institute, Department of Dental Science, Graduate School, Kyungpook National University, Daegu, Republic of Korea
| | - Kyu-Bok Lee
- Professor, Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea.
| |
Collapse
|
66
|
Lu Y, Wang L, Dal Piva AMDO, Tribst JPM, Čokić SM, Zhang F, Werner A, Kleverlaan CJ, Feilzer AJ. Effect of printing layer orientation and polishing on the fatigue strength of 3D-printed dental zirconia. Dent Mater 2024; 40:190-197. [PMID: 37977991 DOI: 10.1016/j.dental.2023.11.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 10/23/2023] [Accepted: 11/04/2023] [Indexed: 11/19/2023]
Abstract
OBJECTIVE The aim of the study was to evaluate the influence of surface polishing and printing layer orientation on the fatigue behaviour of 3 mol% yttria-stabilized zirconia (3Y-TZP) by stereolithography (SLA) in comparison with subtractive manufacturing. MATERIALS AND METHODS 60 experimental zirconia bar-shaped specimens were 3D-printed (P) via SLA, and 30 specimens were milled (M) from commercial zirconia block (Lava™ Frame, 3 M ESPE AG). All specimens had the same dimensions (1 mm × 1 mm x 12 mm) after sintering. The 3D-printed specimens were randomly divided according to printing orientations: parallel or perpendicular to the tensile surface in the fatigue test. The specimens were subsequently submitted to two surface finishing protocols (n = 15/gr): unpolished or polished. Their phase compositions were analysed by X-ray diffraction. The fatigue behaviour was evaluated by a stepwise approach. RESULTS The milled and both 3D-printed groups showed similar phase compositions for the as-sintered condition. Considerable amounts of rhombohedral phase were detected after polishing. Milled unpolished samples presented significantly higher fatigue strength than 3D-printed unpolished samples. Polishing did not improve the fatigue strength for milled zirconia but was advantageous for the 3D-printed specimens. 3D-printed specimens with parallel printing-layer orientation were significantly stronger than specimens with perpendicular layers regardless of surface finishing. CONCLUSION The manufacturing techniques had a significant influence on the fatigue strength of 3Y-TZP, but not on the phase compositions of the surface. The polishing protocol showed different effects on 3Y-TZP fatigue strength and induced phase transition of the 3Y-TZP from Tetragonal to Rhombohedral. The best fatigue strength was achieved through milling using an unpolished surface and SLA-printed layers that were parallel to the tensile surface, followed by polishing.
Collapse
Affiliation(s)
- Yuqing Lu
- Department of Dental Materials Science, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, the Netherlands
| | - Li Wang
- Jiangsu Key Laboratory of Advanced Food Manufacturing Equipment and Technology, School of Mechanical Engineering, Jiangnan University, Wuxi 214122, Jiangsu, China; Institute of Advanced Technology, Jiangnan University, Wuxi 214122, Jiangsu, China
| | - Amanda Maria de Oliveira Dal Piva
- Department of Dental Materials Science, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, the Netherlands
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, the Netherlands.
| | - Stevan M Čokić
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & University Hospitals Leuven (UZ Leuven), Dentistry, Leuven, Belgium
| | - Fei Zhang
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & University Hospitals Leuven (UZ Leuven), Dentistry, Leuven, Belgium; KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001 Leuven, Belgium
| | - Arie Werner
- Department of Dental Materials Science, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, the Netherlands
| | - Cornelis J Kleverlaan
- Department of Dental Materials Science, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, the Netherlands
| | - Albert J Feilzer
- Department of Dental Materials Science, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, the Netherlands; Department of Reconstructive Oral Care, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, the Netherlands
| |
Collapse
|
67
|
Ferreira I, Calazans Neto JV, Cândido dos Reis A. Artificial teeth obtained by additive manufacturing: Wear resistance aspects. A systematic review of in vitro studies. Heliyon 2024; 10:e23279. [PMID: 38163102 PMCID: PMC10754871 DOI: 10.1016/j.heliyon.2023.e23279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 10/27/2023] [Accepted: 11/30/2023] [Indexed: 01/03/2024] Open
Abstract
Wear resistance is one of the properties that must be considered for maintaining the long-term functionality of artificial teeth in dental prostheses. This property can be altered by the method of tooth fabrication, the material, the chewing force, and the relationship to the antagonist tooth. This systematic review evaluated the wear resistance of artificial teeth obtained by the additive manufacturing method and aims to answer the question, "Do artificial teeth for dental prostheses obtained by additive manufacturing show wear resistance similar to prefabricated ones?" The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Checklist guidelines were followed with a customized search in Scopus, PubMed/Medline, Embase, Science Direct, and Google Scholar databases on August 30, 2023. The inclusion criteria were artificial teeth for dental prostheses in acrylic resin by additive manufacturing and comparing the wear resistance with conventional prefabricated teeth, in vitro and English studies, without time restriction. And excluded if 1) do not make artificial teeth by additive manufacturing or that were metal or ceramic teeth; 2) clinical trials, animal studies, review articles, case reports, letters to the editor, short communication, book chapters; 3) another language that is not English. The selection was in two steps, reading the titles and abstracts, followed by reading the selected studies in full. The risk of bias analysis was performed with the adaptation of the quasi-experimental studies tool by Joanna Briggs Institute. Four hundred and twelve articles were found in the databases, after the selection steps and application of eligibility criteria, 6 articles were included for qualitative data analysis and presented low risk of bias. For teeth obtained by additive manufacturing, 2 studies reported lower wear resistance, 2 studies had higher resistance, and 2 similar compared to prefabricated ones. Additive manufactured teeth compared to prefabricated teeth show influences on wear resistance due to differences in material composition, relationship to the antagonist's tooth, applied force, chewing cycles, and processing methods.
Collapse
Affiliation(s)
- Izabela Ferreira
- Department of Dental Materials and Prosthesis, Ribeirão Preto School of Dentistry, University of São Paulo (USP), Ribeirão Preto, Brazil
| | - João Vicente Calazans Neto
- Department of Dental Materials and Prosthesis, Ribeirão Preto School of Dentistry, University of São Paulo (USP), Ribeirão Preto, Brazil
| | - Andréa Cândido dos Reis
- Department of Dental Materials and Prosthesis, Ribeirão Preto School of Dentistry, University of São Paulo (USP), Ribeirão Preto, Brazil
| |
Collapse
|
68
|
Saini RS, Gurumurthy V, Quadri SA, Bavabeedu SS, Abdelaziz KM, Okshah A, Alshadidi AAF, Yessayan L, Mosaddad SA, Heboyan A. The flexural strength of 3D-printed provisional restorations fabricated with different resins: a systematic review and meta-analysis. BMC Oral Health 2024; 24:66. [PMID: 38200473 PMCID: PMC10782672 DOI: 10.1186/s12903-023-03826-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 12/25/2023] [Indexed: 01/12/2024] Open
Abstract
BACKGROUND Three-dimensional (3D) printing technology has revolutionized dentistry, particularly in fabricating provisional restorations. This systematic review and meta-analysis aimed to thoroughly evaluate the flexural strength of provisional restorations produced using 3D printing while considering the impact of different resin materials. METHODS A systematic search was conducted across major databases (ScienceDirect, PubMed, Web of Sciences, Google Scholar, and Scopus) to identify relevant studies published to date. The inclusion criteria included studies evaluating the flexural strength of 3D-printed provisional restorations using different resins. Data extraction and quality assessment were performed using the CONSORT scale, and a meta-analysis was conducted using RevMan 5.4 to pool results. RESULTS Of the 1914 initially identified research articles, only 13, published between January 2016 and November 2023, were included after screening. Notably, Digital Light Processing (DLP) has emerged as the predominant 3D printing technique, while stereolithography (SLA), Fused Deposition Modeling (FDM), and mono-liquid crystal displays (LCD) have also been recognized. Various printed resins have been utilized in different techniques, including acrylic, composite resins, and methacrylate oligomer-based materials. Regarding flexural strength, polymerization played a pivotal role for resins used in 3D or conventional/milled resins, revealing significant variations in the study. For instance, SLA-3D and DLP Acrylate photopolymers displayed distinct strengths, along with DLP bisacrylic, milled PMMA, and conventional PMMA. The subsequent meta-analysis indicated a significant difference in flexure strength, with a pooled Mean Difference (MD) of - 1.25 (95% CI - 16.98 - 14.47; P < 0.00001) and a high I2 value of 99%, highlighting substantial heterogeneity among the studies. CONCLUSIONS This study provides a comprehensive overview of the flexural strength of 3D-printed provisional restorations fabricated using different resins. However, further research is recommended to explore additional factors influencing flexural strength and refine the recommendations for enhancing the performance of 3D-printed provisional restorations in clinical applications.
Collapse
Affiliation(s)
- Ravinder S Saini
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | | | | | - Shashit Shetty Bavabeedu
- Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Khalid M Abdelaziz
- Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Abdulmajeed Okshah
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | | | - Lazar Yessayan
- Department of Therapeutic Stomatology, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Yerevan, Armenia
| | - Seyed Ali Mosaddad
- Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - Artak Heboyan
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Yerevan, Armenia.
| |
Collapse
|
69
|
Chander NG, Mahajan A. Comparison of cytotoxicity between 3D printable resins and heat-cure PMMA. J Oral Biol Craniofac Res 2024; 14:107-110. [PMID: 38304040 PMCID: PMC10831252 DOI: 10.1016/j.jobcr.2024.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 12/06/2023] [Accepted: 01/10/2024] [Indexed: 02/03/2024] Open
Abstract
Aim The aim of this study was to evaluate and compare the cytotoxicity of polyurethane and polyoxymethylene printable resins with conventional heat cure polymethyl methacrylate denture base resins. Methods The study followed ISO-10993-5 guidelines. It comprised of three groups. Fifteen cuboidal samples measuring 10x10 × 10mm dimension were prepared for each group. The polymethylmethacrylate samples were fabricated using conventional denture processing techniques, while the polyoxymethylene samples were printed using fused deposition modeling and the polyurethane samples using stereolithography technique. Post fabrication the samples were evaluated for cytotoxicity using the MTT assay with the VERO cell line. The percentage of cell viability was calculated to determine the cytotoxic effects. Results Statistical analysis revealed a significant difference in the cell viability of the experimental groups (p ≤ 0.0001). The polyoxymethylene group showed the highest % cell viability (62.78 %), followed by the polymethylmethacrylate group (52.43 %), and the least was observed in the polyurethane-based resin group (46.47 %). The findings indicate polyoxymethylene group displayed least cytotoxicity, followed by polymethylmethacrylate, and polyurethane-based resin. Conclusion Polyoxymethylene resin exhibited the minimum cytotoxic properties among the tested materials, followed by polymethylmethacrylate and polyurethane resin.
Collapse
Affiliation(s)
- N. Gopi Chander
- Department of Prosthodontics, SRM Dental College, Ramapuram, Chennai, 89, India
| | - Aashmika Mahajan
- Department of Prosthodontics, SRM Dental College, Ramapuram, Chennai, 89, India
| |
Collapse
|
70
|
Peker Ozturk H, Ayyıldız S. Comparison of different 3D printers in terms of dimensional stability by image data of a dry human mandible obtained from CBCT and CT. Int J Artif Organs 2024; 47:49-56. [PMID: 37981804 DOI: 10.1177/03913988231212405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2023]
Abstract
OBJECTIVES To manage the mandibular traumas, for the expression of the complex anatomy or pathology in education of health sciences related branches, a model of the traumatized mandible is indispensable. For these, different 3D-print-technologies can be used. The aim of this study is, to measure how close these 3D-printed-models are to human-mandible (trueness) and the effectiveness of CT and CBCT at this point. STUDY DESIGN One-dry-human-mandible and 10-models manufactured by five different 3D-printers in four different-kinds of additive-manufacturing technology (Fused-Deposition-Modeling (FDM), Stereolithography (SLA), Binder-jetting (BJ), Polyjet (PJ)) were used, five-anatomic-landmarks and eight-distances were measured and evaluated. Mandible's data were constructed based on DICOM-3.0 data from CBCT and CT scans. Images were opened in MIMICS (software-program). RESULTS Study compared the devices that produced models with the same dry human-mandible. It was seen that the model with the highest margin of error (132.5 mm) was manufactured by Fused-deposition-modeling device using CT-data. In terms of distance to real-data, the model with the lowest error was generated by Binder-Jetting (ZCorp) with CBCT-data. Models produced with CBCT-data are closer to dry-human-mandible than models with CT-data. CONCLUSION The current study shows that CBCT generates significantly better data than CT in producing mandibular models. The first choice for manufacturing of human mandible is BJ and the second choice is the technology of SLA.
Collapse
Affiliation(s)
- Hilal Peker Ozturk
- Department of Dento Maxillofacial Radiology, Gulhane Faculty of Dentistry, University of Health Sciences, Ankara, Turkey
| | - Simel Ayyıldız
- Department of Prosthodontics, Gulhane Faculty of Dentistry, University of Health Sciences, Ankara, Turkey
| |
Collapse
|
71
|
Prakash J, Shenoy M, Alhasmi A, Al Saleh AA, C SG, Shivakumar S. Biocompatibility of 3D-Printed Dental Resins: A Systematic Review. Cureus 2024; 16:e51721. [PMID: 38318586 PMCID: PMC10839546 DOI: 10.7759/cureus.51721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 01/05/2024] [Indexed: 02/07/2024] Open
Abstract
BACKGROUND The biocompatibility of 3D-printed dental resins has become a critical concern in modern dentistry due to the increasing utilization of additive manufacturing (AM) techniques in dental applications. These resins serve as essential materials for fabricating dental prostheses, orthodontic devices, and various dental components. As the clinical adoption of 3D printing in dentistry grows, it is imperative to comprehensively assess the biocompatibility of these materials to ensure patient safety and dental treatment efficacy. This systematic review aimed to evaluate the existing body of literature on the biocompatibility of 3D-printed dental resins, thereby providing valuable insights into the potential biological risks associated with their use. METHODS The search strategy to identify relevant papers was implemented across PubMed/MEDLINE, Scopus, Web of Science, Embase, Cochrane Library, CINAHL, and Google Scholar to identify relevant studies. Study selection was not limited to any particular timeframe of publishing. The revised CONSORT criteria were used to ascertain the authenticity and dependability of the review's outcomes. Comprehensive screening and eligibility assessment processes were conducted to select studies meeting predefined criteria. Biocompatibility-related parameters, including toxicity, mechanical properties, cell viability, and other relevant outcomes, were analyzed across selected studies using a standardized variable extraction protocol. RESULTS A total of 9 studies were included in the systematic review. The findings encompassed various aspects of biocompatibility assessment, including material composition, mechanical properties, cell viability, and cytotoxicity. Some studies revealed significant improvements in flexural strength and cell viability with specific resin formulations, demonstrating their potential for enhanced clinical utility. Conversely, certain resins exhibited cytotoxicity, while others displayed promising biocompatibility profiles. CONCLUSION As per the assessed findings, material composition, post-processing techniques, and manufacturing methods emerged as critical factors influencing biocompatibility outcomes. While some resins exhibited favorable biocompatibility profiles, others raised concerns due to cytotoxicity. These findings emphasize the need for careful consideration when selecting and implementing 3D-printed dental resins, with a focus on materials engineering and comprehensive biocompatibility testing. Further research is warranted to elucidate the long-term biocompatibility and clinical implications of these materials.
Collapse
Affiliation(s)
- Jayant Prakash
- Department of Prosthodontics, Dental Institute, Rajendra Institute of Medical Sciences, Ranchi, IND
| | - Mahesh Shenoy
- Department of Oral and Maxillofacial Surgery and Diagnostic Sciences, College of Medicine and Dentistry, Riyadh Elm University, Riyadh, SAU
| | - Abdulmajeed Alhasmi
- Department of Periodontics, King Salman Hospital, Ministry of Health, Riyadh, SAU
| | | | - Shivakumar G C
- Department of Oral Medicine and Radiology, People's College of Dental Sciences and Research Centre, Bhopal, IND
| | - Sahana Shivakumar
- Department of Public Health Dentistry, People's College of Dental Sciences and Research Centre, Bhopal, IND
| |
Collapse
|
72
|
Sahrir CD, Ruslin M, Lee SY, Lin WC. Effect of various post-curing light intensities, times, and energy levels on the color of 3D-printed resin crowns. J Dent Sci 2024; 19:357-363. [PMID: 38303871 PMCID: PMC10829711 DOI: 10.1016/j.jds.2023.07.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 07/06/2023] [Indexed: 02/03/2024] Open
Abstract
Background/purpose Current 3D-printing technology has been widely used for creating dental resin restorations. This study aimed to evaluate the effect of light intensity, time, and energy post-curing on the surface color of 3D-printed resin crowns. However, the influences of post-curing parameters on the restoration after printing still need to be explored. Therefore, this project investigates the effect of post-cure conditions on resin color. Materials and methods Specimens from single-crown (SC) and pontic (PO) specimens underwent post-curing at various light intensities (105, 210, 420, 630, and 860 mW/cm2) for 5, 10, and 15 min. Specimens were observed at three predetermined points and measured using a commercial spectrophotometer that utilizes the CIE Lab∗ color space. Subsequently, samples were analyzed for color differences (ΔE). Results ΔE color differences in evaluated samples were influenced by the light intensity, time, and energy post-curing. SC samples showed a significant color difference (P < 0.05), with the lowest value at 5 min of 16 (860 mW/cm2), while 10 and 15 min had a difference of 4 (210 mW/cm2). PO samples exhibited a significant decrease in the color difference (P < 0.05) at 5 and 10 min of 16 (860 mW/cm2), and at 15 min of 12 (630 mW/cm2). Conclusion The results of this study indicate that exposing a resin crown to a high light intensity results in color stability and allows shorter post-curing times.
Collapse
Affiliation(s)
- Citra Dewi Sahrir
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Muhammad Ruslin
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Hasanuddin University, Makassar, Indonesia
| | - Sheng-Yang Lee
- Department of Dentistry, Wan-Fang Hospital, Taipei Medical University, Taipei, Taiwan
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
- Center for Tooth Bank and Dental Stem Cell Technology, Taipei Medical University, Taipei, Taiwan
| | - Wei-Chun Lin
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
- Department of Dentistry, Wan-Fang Hospital, Taipei Medical University, Taipei, Taiwan
- Center for Tooth Bank and Dental Stem Cell Technology, Taipei Medical University, Taipei, Taiwan
| |
Collapse
|
73
|
Su G, Zhang Y, Jin C, Zhang Q, Lu J, Liu Z, Wang Q, Zhang X, Ma J. 3D printed zirconia used as dental materials: a critical review. J Biol Eng 2023; 17:78. [PMID: 38129905 PMCID: PMC10740276 DOI: 10.1186/s13036-023-00396-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Accepted: 11/27/2023] [Indexed: 12/23/2023] Open
Abstract
In view of its high mechanical performance, outstanding aesthetic qualities, and biological stability, zirconia has been widely used in the fields of dentistry. Due to its potential to produce suitable advanced configurations and structures for a number of medical applications, especially personalized created devices, ceramic additive manufacturing (AM) has been attracting a great deal of attention in recent years. AM zirconia hews out infinite possibilities that are otherwise barely possible with traditional processes thanks to its freedom and efficiency. In the review, AM zirconia's physical and adhesive characteristics, accuracy, biocompatibility, as well as their clinical applications have been reviewed. Here, we highlight the accuracy and biocompatibility of 3D printed zirconia. Also, current obstacles and a forecast of AM zirconia for its development and improvement have been covered. In summary, this review offers a description of the basic characteristics of AM zirconia materials intended for oral medicine. Furthermore, it provides a generally novel and fundamental basis for the utilization of 3D printed zirconia in dentistry.
Collapse
Affiliation(s)
- Guanyu Su
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China
| | - Yushi Zhang
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China
| | - Chunyu Jin
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China
| | - Qiyue Zhang
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China
| | - Jiarui Lu
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China
| | - Zengqian Liu
- Shi-Changxu Innovation Center for Advanced Materials, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016, China
- School of Materials Science and Engineering, University of Science and Technology of China, Hefei, 230026, China
| | - Qiang Wang
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China
| | - Xue Zhang
- Department of Orthodontics, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China.
| | - Jia Ma
- Department of Orthodontics, School and Hospital of Stomatology, China Medical University, No. 117 Nanjing North Street, Shenyang, 110001, China.
| |
Collapse
|
74
|
Jeong M, Radomski K, Lopez D, Liu JT, Lee JD, Lee SJ. Materials and Applications of 3D Printing Technology in Dentistry: An Overview. Dent J (Basel) 2023; 12:1. [PMID: 38275676 PMCID: PMC10814684 DOI: 10.3390/dj12010001] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 12/05/2023] [Accepted: 12/14/2023] [Indexed: 01/27/2024] Open
Abstract
PURPOSE This narrative review aims to provide an overview of the mechanisms of 3D printing, the dental materials relevant to each mechanism, and the possible applications of these materials within different areas of dentistry. METHODS Subtopics within 3D printing technology in dentistry were identified and divided among five reviewers. Electronic searches of the Medline (PubMed) database were performed with the following search keywords: 3D printing, digital light processing, stereolithography, digital dentistry, dental materials, and a combination of the keywords. For this review, only studies or review papers investigating 3D printing technology for dental or medical applications were included. Due to the nature of this review, no formal evidence-based quality assessment was performed, and the search was limited to the English language without further restrictions. RESULTS A total of 64 articles were included. The significant applications, applied materials, limitations, and future directions of 3D printing technology were reviewed. Subtopics include the chronological evolution of 3D printing technology, the mechanisms of 3D printing technologies along with different printable materials with unique biomechanical properties, and the wide range of applications for 3D printing in dentistry. CONCLUSIONS This review article gives an overview of the history and evolution of 3D printing technology, as well as its associated advantages and disadvantages. Current 3D printing technologies include stereolithography, digital light processing, fused deposition modeling, selective laser sintering/melting, photopolymer jetting, powder binder, and 3D laser bioprinting. The main categories of 3D printing materials are polymers, metals, and ceramics. Despite limitations in printing accuracy and quality, 3D printing technology is now able to offer us a wide variety of potential applications in different fields of dentistry, including prosthodontics, implantology, oral and maxillofacial, orthodontics, endodontics, and periodontics. Understanding the existing spectrum of 3D printing applications in dentistry will serve to further expand its use in the dental field. Three-dimensional printing technology has brought about a paradigm shift in the delivery of clinical care in medicine and dentistry. The clinical use of 3D printing has created versatile applications which streamline our digital workflow. Technological advancements have also paved the way for the integration of new dental materials into dentistry.
Collapse
Affiliation(s)
- Min Jeong
- Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, MA 02115, USA; (M.J.); (K.R.); (D.L.); (J.D.L.)
| | - Kyle Radomski
- Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, MA 02115, USA; (M.J.); (K.R.); (D.L.); (J.D.L.)
| | - Diana Lopez
- Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, MA 02115, USA; (M.J.); (K.R.); (D.L.); (J.D.L.)
| | - Jack T. Liu
- Dexter Southfield, Brookline, MA 02445, USA;
| | - Jason D. Lee
- Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, MA 02115, USA; (M.J.); (K.R.); (D.L.); (J.D.L.)
| | - Sang J. Lee
- Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, MA 02115, USA; (M.J.); (K.R.); (D.L.); (J.D.L.)
| |
Collapse
|
75
|
Huang L, Liu L, Yang S, Khadka P, Zhang S. Evaluation of the accuracy of implant placement by using implant positional guide versus freehand: a prospective clinical study. Int J Implant Dent 2023; 9:45. [PMID: 38036932 PMCID: PMC10689697 DOI: 10.1186/s40729-023-00512-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 11/05/2023] [Indexed: 12/02/2023] Open
Abstract
PURPOSE The aim of this study is to examine and compare the accuracy of implant placement using implant positional guide and freehand. METHODS 48 implants were placed in patients with single tooth loss with implant positional guide and freehand, respectively. The accuracy of implant placement was assessed by comparing the actual and planned position, including four parameters: coronal deviation, apical deviation, angular deviation, and vertical deviation. RESULTS Comparing all the variables, it has been found that the implant positional guide is more accurate than the freehand. All parameters describing in the deviation were significantly lower in the implant positional guide group than the freehand. CONCLUSIONS The implant positional guide can act as a practicable tool for dental implant surgery. It is a promising technology that guarantees low cost and high precision in implant surgery. However, based on the restricted evidence from clinical studies, longer follow-up periods, larger population studies, and standardized experimental studies are required. Trial registration CHICTR, ChiCTR2300071024. Registered 28 April 2023-CHICTR, ChiCTR2300071024. Registered 28 April 2023-Retrospectively registered, https://www.chictr.org.cn/showproj.html?proj=195424 .
Collapse
Affiliation(s)
- Lixuan Huang
- State Key Laboratory of Oral Diseases and National Center for Stomatology and National Clinical Research Center for Oral Diseases, Chengdu, People's Republic of China
| | - Linfeng Liu
- State Key Laboratory of Oral Diseases and National Center for Stomatology and National Clinical Research Center for Oral Diseases, Chengdu, People's Republic of China
| | - Shengtao Yang
- State Key Laboratory of Oral Diseases and National Center for Stomatology and National Clinical Research Center for Oral Diseases, Chengdu, People's Republic of China
| | - Prapti Khadka
- Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, People's Republic of China
| | - Shiwen Zhang
- State Key Laboratory of Oral Diseases and National Center for Stomatology and National Clinical Research Center for Oral Diseases, Chengdu, People's Republic of China.
- Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, People's Republic of China.
| |
Collapse
|
76
|
Albergaria LS, Scotti CK, Mondelli RFL, Vega HA, Faggion CM, Bombonatti JFS, Velo MMDAC. Effect of nanofibers as reinforcement on resin-based dental materials: A systematic review of in vitro studies. JAPANESE DENTAL SCIENCE REVIEW 2023; 59:239-252. [PMID: 37593731 PMCID: PMC10429726 DOI: 10.1016/j.jdsr.2023.07.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 04/16/2023] [Accepted: 07/12/2023] [Indexed: 08/19/2023] Open
Abstract
This systematic review provides an update on the effect of nanofibers as reinforcement on resin-based dental materials. A bibliographic search was conducted in MEDLINEPubMed, Embase, Web of Science, Scopus, BVS (LILACS, BBO e IBECS), Cochrane, LIVIVO, and gray literature (BDTD) to identify relevant articles up to May 2021. In vitro studies that evaluated and compared the mechanical properties of nanofibers resin-based composite materials, were eligible. No publication year or language restriction was applied, and methodological quality was assessed using two methods. In a total of 6100 potentially eligible studies, 81 were selected for full-text analysis and 35 were included for qualitative analysis. Of the 35 included studies, a total of 29 studies evaluated the flexural strength (FS) of the materials. These groups were distinguished according to the resin-based materials tested and nanofiber types. Most of the studies evaluated materials composed of glass fibers and demonstrated higher values of FS when compared to resin-based materials without nanofibers. The incorporation of nanofibers into resin-based dental materials improved the mechanical properties compared to resin-based materials without nanofibers, suggesting better performance of these materials in high-stressbearing application areas. Further clinical studies are required to confirm the efficacy of resin-based materials with nanofibers.
Collapse
Affiliation(s)
- Laís Santos Albergaria
- Department of Operative Dentistry, Endodontics, and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, São Paulo, Brazil
| | - Cassiana Koch Scotti
- Department of Operative Dentistry, Endodontics, and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, São Paulo, Brazil
| | - Rafael Francisco Lia Mondelli
- Department of Operative Dentistry, Endodontics, and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, São Paulo, Brazil
| | - Heber Arbildo Vega
- Faculty of Dentistry, Department of General Dentistry, San Martín de Porres University, Chiclayo, Peru
- Faculty of Human Medicine, Department of Human Medicine, San Martín de Porres University, Chiclayo, Peru
| | - Clovis Mariano Faggion
- Department of Periodontology and Operative Dentistry, Faculty of Dentistry, University Hospital Münster, Münster, Germany
| | - Juliana Fraga Soares Bombonatti
- Department of Operative Dentistry, Endodontics, and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, São Paulo, Brazil
| | - Marilia Mattar de Amoêdo Campos Velo
- Department of Operative Dentistry, Endodontics, and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, São Paulo, Brazil
| |
Collapse
|
77
|
Singh TS, Bhola N, Reche A. The Utility of 3D Printing for Surgical Planning and Patient-Specific Implant Design in Maxillofacial Surgery: A Narrative Review. Cureus 2023; 15:e48242. [PMID: 38054128 PMCID: PMC10695083 DOI: 10.7759/cureus.48242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 11/03/2023] [Indexed: 12/07/2023] Open
Abstract
Maxillofacial reconstructive implants are typically created in standard shapes and have a widespread application in head and neck surgery. During surgical procedures, the implant must be correctly bent according to the architecture of the particular bones. Bending takes practice, especially for untrained surgeons. Furthermore, repeated bending may increase internal stress, resulting in fatigue in vivo under masticatory loading and an array of consequences, including implant failure. There is a risk of fracture, screw loosening, and bone resorption. Resorption, infection, and displacement are usually associated with the use of premade alloplastic implants and autogenous grafts. Recent technological breakthroughs have led to the use of patient-specific implants (PSIs) developed by computer-designed additive manufacturing in reconstructive surgery. The use of computer-designed three-dimensional (3D)-printed PSI allows for more precise restoration of maxillofacial deformities, avoiding the common difficulties associated with premade implants and increasing patient satisfaction. Additive manufacturing is something that refers to a group of additive manufacturing methods. This technique has been quickly used in a variety of surgical procedures. The exponential expansion of this technology can be attributed to its enormous surgical value. Adding 3D printing to a medical practice can be a rewarding experience with stunning results.
Collapse
Affiliation(s)
- Tanvi S Singh
- Oral and Maxillofacial Surgery, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research (DMIHER), Wardha, IND
| | - Nitin Bhola
- Oral and Maxillofacial Surgery, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research (DMIHER), Wardha, IND
| | - Amit Reche
- Public Health Dentistry, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research (DMIHER), Wardha, IND
| |
Collapse
|
78
|
Yang Y, Qiu B, Zhou Z, Hu C, Li J, Zhou C. Three-Dimensional Printing of Polycaprolactone/Nano-Hydroxyapatite Composite Scaffolds with a Pore Size of 300/500 µm is Histocompatible and Promotes Osteogenesis Using Rabbit Cortical Bone Marrow Stem Cells. Ann Transplant 2023; 28:e940365. [PMID: 37904328 PMCID: PMC10625337 DOI: 10.12659/aot.940365] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Accepted: 07/12/2023] [Indexed: 11/01/2023] Open
Abstract
BACKGROUND Many patients have bone defects that exceed the healing size. This study aimed to construct polycaprolactone/nano-hydroxyapatite (PCL/nHA) composite scaffolds with different pore sizes and investigate the osteogenesis and histocompatibility of cortical bone mesenchymal stem cells (BMSCs-C) seeded on it after inoculation. MATERIAL AND METHODS After mixing PCL and nHA proportionally, three-dimensional (3D) printing was used to print scaffolds. Porosity, compressive strength, and elastic modulus of PCL/nHA scaffolds were tested. The proliferation of BMSCs-C cells was examined and osteogenesis, chondrogenesis, and adipogenesis were evaluated. BMSCs-C cells were inoculated into 3D printing scaffolds, and histocompatibility between BMSCs-C cells and scaffolds was observed by the cell count kit (CCK-8) assay and LIVE/DEAD staining. After inoculating BMSCs-C cells into scaffolds, alkaline phosphatase (ALP) activity and calcium content were measured. RESULTS There was no obvious difference in characteristics between the 3 PCL/nHA composite scaffolds. The porosity, compressive strength, and elastic modulus of the 300/500-μm scaffold were between those of the 300-μm and 500-μm scaffolds. With increasing pore size, the mechanical properties of the scaffold decrease. BMSCs-C cells demonstrated faster growth and better osteogenic, adipogenic, and chondrogenic differentiation; therefore, BMSCs-C cells were selected as seed cells. PCL/nHA composite scaffolds with different pore sizes had no obvious toxicity and demonstrated good biocompatibility. All scaffolds showed higher ALP activity and calcium content. CONCLUSIONS The 300/500 μm mixed pore size scaffold took into account the mechanical properties of the 300 μm scaffold and the cell culture area of the 500 μm scaffold, therefore, 300/500 μm scaffold is a better model for the construction of tissue engineering scaffolds.
Collapse
|
79
|
Cantó-Navés O, Michels K, Figueras-Alvarez O, Fernández-Villar S, Cabratosa-Termes J, Roig M. In Vitro Comparison of Internal and Marginal Adaptation between Printed and Milled Onlays. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6962. [PMID: 37959559 PMCID: PMC10650727 DOI: 10.3390/ma16216962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 10/16/2023] [Accepted: 10/26/2023] [Indexed: 11/15/2023]
Abstract
STATEMENT OF PROBLEM Nowadays, milling is still the gold standard for fabricating indirect restorations, but to overcome its disadvantages, there are alternatives, such as 3D printing. PURPOSE This study aimed to compare the gaps between the prepared tooth and milled and printed onlays fabricated with the same CAD design. It also aimed to determine the gap reproducibility across onlays fabricated by 3D printing and milling. METHODS A resin tooth was prepared for an onlay. After scanning the preparation, an onlay was designed with proprietary dental software. Next, 22 onlays were milled in a graphene-reinforced PMMA disc (Group 1), and 22 onlays were 3D-printed with a hybrid composite material (Group 2). After that, all fabricated restorations were scanned and superimposed on the scanned prepared resin tooth. Subsequently, a specific software was used to measure the margin, central, and intaglio-located gap between the milled or printed restoration and the preparation. Finally, measurements were compared with a multifactor analysis of variance. RESULTS The results demonstrated that printed onlays (Group 2) adapted better to the prepared tooth than the milled ones (Group 1) (p < 0.05). The comparison of standard deviations showed the better gap reproducibility of printed onlays (p < 0.05). CONCLUSION This study concluded that the printed onlays adapted significantly better to the prepared tooth than the milled onlays. Printed onlays also showed significantly better gap reproducibility.
Collapse
Affiliation(s)
- Oriol Cantó-Navés
- Department of Restorative Dentistry, Universitat Internacional de Catalunya, 08195 Sant Cugat del Vallès, Barcelona, Spain; (O.C.-N.); (S.F.-V.); (J.C.-T.); (M.R.)
| | - Kyra Michels
- Universitat Internacional de Catalunya, 08195 Sant Cugat del Vallès, Barcelona, Spain;
| | - Oscar Figueras-Alvarez
- Department of Restorative Dentistry, Universitat Internacional de Catalunya, 08195 Sant Cugat del Vallès, Barcelona, Spain; (O.C.-N.); (S.F.-V.); (J.C.-T.); (M.R.)
| | - Sandra Fernández-Villar
- Department of Restorative Dentistry, Universitat Internacional de Catalunya, 08195 Sant Cugat del Vallès, Barcelona, Spain; (O.C.-N.); (S.F.-V.); (J.C.-T.); (M.R.)
| | - Josep Cabratosa-Termes
- Department of Restorative Dentistry, Universitat Internacional de Catalunya, 08195 Sant Cugat del Vallès, Barcelona, Spain; (O.C.-N.); (S.F.-V.); (J.C.-T.); (M.R.)
| | - Miguel Roig
- Department of Restorative Dentistry, Universitat Internacional de Catalunya, 08195 Sant Cugat del Vallès, Barcelona, Spain; (O.C.-N.); (S.F.-V.); (J.C.-T.); (M.R.)
| |
Collapse
|
80
|
Espinar C, Della Bona A, Tejada-Casado M, Pulgar R, Pérez MM. Optical behavior of 3D-printed dental restorative resins: Influence of thickness and printing angle. Dent Mater 2023; 39:894-902. [PMID: 37598040 DOI: 10.1016/j.dental.2023.08.003] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 07/27/2023] [Accepted: 08/07/2023] [Indexed: 08/21/2023]
Abstract
OBJECTIVES To evaluate the influence of thickness and printing angle on the optical properties of 3D-printed dental restorative resins. METHODS Four 3D printing resin systems were evaluated: DFT-Detax Freeprint Temp; FP- Formlabs Permanent Crown; FP- Formlabs Temporary CB; and GCT- GC Temporary-. Samples from each material were printed at 0° and 90°, and polished up to 0.5, 1.0, 1.5 and 2.0 mm thickness. Scattering (S), absorption (K) and albedo (a) coefficients, transmittance (T%), light reflectivity (RI) and infinite optical thickness (X∞) were calculated using Kubelka-Munk's model. Data were statistically analyzed using Kruskal-Wallis¸ Mann-Whitney tests, and VAF coefficient. RESULTS The spectral distribution on S, K, T%, RI,X∞ were wavelength dependent. Although the spectral behaviors were similar for all the specimens evaluated, the values of S, K, T% andX∞ presented significant differences between specimen thicknesses for all the materials used and for both printing orientations. Values for S and K increased, and T% and X∞ decreased. Significant differences between 0° and 90° were found for RI values at 0.5 and 1.0 mm thick samples, for S and K at 2.0 mm, for X∞ at 0.5 and 1.0 mm for DFT, and at 0.5 mm for FT. CONCLUSIONS Optical properties of 3D-printed restorative resins vary between thicknesses, and could be affected by the building orientation. Therefore, these factors should be considered in order to improve the biomimetic potential of 3D-printed dental restorative resins. CLINICAL SIGNIFICANCE Understanding the optical behavior of the 3D-printed restorative resins is essential to optimize their clinical performance.
Collapse
Affiliation(s)
- Cristina Espinar
- Department of Stomatology, Faculty of Dentistry, Colegio Máximo, Campus de Cartuja s/n. University of Granada, 18071, Granada, Spain
| | - Alvaro Della Bona
- Post-Graduate Program in Dentistry, Dental School, University of Passo Fundo, Campus I, Passo Fundo, RS, Brazil
| | - Maria Tejada-Casado
- Department of Optics, Faculty of Science, Campus Fuentenueva, Edificio Mecenas, s/n. University of Granada, 18071, Granada, Spain
| | - Rosa Pulgar
- Department of Stomatology, Faculty of Dentistry, Colegio Máximo, Campus de Cartuja s/n. University of Granada, 18071, Granada, Spain
| | - María M Pérez
- Department of Optics, Faculty of Science, Campus Fuentenueva, Edificio Mecenas, s/n. University of Granada, 18071, Granada, Spain.
| |
Collapse
|
81
|
Hasanzade M, Yaghoobi N, Nematollahi P, Ghazanfari R. Comparison of the marginal and internal fit of PMMA interim crowns printed with different layer thicknesses in 3D-printing technique. Clin Exp Dent Res 2023; 9:832-839. [PMID: 37386767 PMCID: PMC10582242 DOI: 10.1002/cre2.758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 06/02/2023] [Accepted: 06/17/2023] [Indexed: 07/01/2023] Open
Abstract
OBJECTIVE The aim of this in vitro study was to compare the effect of printing layer thickness on the marginal and internal fit of interim crowns. MATERIAL AND METHODS A maxillary first molar model was prepared for ceramic restoration. Thirty-six crowns were printed with three different layer thicknesses using a digital light processing-based three-dimensional printer (25, 50, and 100 µm [LT 25, LT 50, and LT 100]). The marginal and internal gaps of the crowns were measured with replica technique. An analysis of variance was conducted to determine if there were significant differences between the groups (ɑ = .05). RESULTS The marginal gap of LT 100 group was significantly higher than that LT 25 (p = .002) and LT 50 groups (p ≤ .001). The LT 25 group has significantly larger axial gaps than LT 50 group (p = .013); however, there were no statistically significant differences between other groups. The LT 50 group showed the smallest axio-occlusal gap. The mean occlusal gap differed significantly by printing layer thickness (p ≤ .001), with the largest gap occurring for LT 100. CONCLUSIONS Provisional crowns printed with 50 µm layer thickness provided the best marginal and internal fit. CLINICAL SIGNIFICANCE It is recommended that provisional crowns be printed with a 50 µm layer thickness to ensure optimal marginal and internal fit.
Collapse
Affiliation(s)
- Mahya Hasanzade
- Department of Prosthodontics, School of Dentistry, International CampusTehran University of Medical SciencesTehranIran
| | - Negin Yaghoobi
- Department of Prosthodontics, School of DentistryTehran University of Medical SciencesTehranIran
| | - Parsa Nematollahi
- School of Dentistry, International CampusTehran University of Medical SciencesTehranIran
| | - Rezvaneh Ghazanfari
- Department of Prosthodontics, School of Dentistry, International CampusTehran University of Medical SciencesTehranIran
| |
Collapse
|
82
|
Luna-Domínguez CR, Luna-Domínguez JH, Blatz M. Full-mouth rehabilitation in a completely digital workflow using partially adhesive monolithic zirconia restorations. J ESTHET RESTOR DENT 2023; 35:1050-1057. [PMID: 37026815 DOI: 10.1111/jerd.13048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 03/17/2023] [Accepted: 03/28/2023] [Indexed: 04/08/2023]
Abstract
OBJECTIVE This clinical case describes a completely digital workflow using current digital technologies for a full-mouth adhesive rehabilitation with ultra-translucent multilayer zirconia restorations. CLINICAL CONSIDERATIONS A healthy 60-year-old man with abfractions on all upper and lower molars and severe tooth wear underwent a full-mouth rehabilitation with laminate veneers and partial adhesive restorations. A proper zirconia bonding protocol was realized to provide a durable bond between the ultra-translucent zirconia and the resin cement. Furthermore, the implementation of a digital workflow enables the clinician to have an effective communication during treatment planning and simplify the clinical and laboratory procedures, providing the patient with long-term esthetic treatment and functional results. CONCLUSION The implementation of a completely digital workflow and the use of ultra-translucent multilayer zirconia for indirect adhesive restorations can be an alternative with simplified and predictable procedures for patients with dental wear and teeth discolorations. CLINICAL SIGNIFICANCE The digital workflow described is intended to facilitate the planning and execution of a full-mouth adhesive rehabilitation and demonstrates to clinicians a reliable zirconia bonding concept for minimally invasive anterior and posterior restorations.
Collapse
Affiliation(s)
- Carlos Roberto Luna-Domínguez
- Department of Prosthodontics, Autonomous University of Tamaulipas, School of Dentistry, Tampico-Madero University Center, Tampico, Tamaulipas, Mexico
- Private Practice, Odontología Avanzada, Tampico, Tamaulipas, Mexico
| | - Jorge Humberto Luna-Domínguez
- Private Practice, Odontología Avanzada, Tampico, Tamaulipas, Mexico
- Research Center, Autonomous University of Tamaulipas, School of Dentistry, Tampico-Madero University Center, Tampico, Tamaulipas, Mexico
| | - Markus Blatz
- Department of Preventive and Restorative Sciences, Penn Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
83
|
Gad MM, Alalawi H, Akhtar S, Al-Ghamdi R, Alghamdi R, Al-Jefri A, Al-Qarni FD. Strength and Wear Behavior of Three-Dimensional Printed and Prefabricated Denture Teeth: An In Vitro Comparative Analysis. Eur J Dent 2023; 17:1248-1256. [PMID: 36669653 PMCID: PMC10756787 DOI: 10.1055/s-0042-1759885] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
OBJECTIVES With advanced technology for complete denture fabrication, there is a lack of knowledge on the mechanical behavior of three-dimensional (3D) printed teeth despite the development of complete denture fabrication technologies. This study aimed to compare different types of 3D-printed teeth in terms of wear and fracture resistance in comparison to control prefabricated denture teeth. MATERIALS AND METHODS One prefabricated tooth was selected and fixed in a resin holder and half of the tooth remained in anatomic form, while the other half was flattened for the wear test. One from each type was scanned and then printed with different resins; Asiga (DentaTOOTH, Asiga, Alexandria 2015,NSW, Australia), FormLabs (Denture Base LP, FormLabs, Berlin, Germany), and NextDent (NextDent C&B MFH, NextDent B.V., Soesterberg, the Netherlands) according to manufacturer recommendations. A total of 60 specimens (20/resin, n = 10) were thermo cycled (5,000 cycles) and wear test samples were further subjected to cyclic loading (1,70,000 cycles) in a chewing simulator machine CS-4.2 (SD Mechatronik GmbH, Germany). The fracture strength of anatomic teeth was measured using a universal testing machine (Instron model 5965, Massachusetts, United States), while Geomagic Control X software was used to assess the amount of wear of flattened teeth. Statistical analyses were performed with one-way analysis of variance with Tukey's post hoc test at significance level of α = 0.05. RESULTS NextDent specimens showed the greatest volume loss, whereas FormLabs specimens showed the least volume loss. Comparing NextDent specimens to FromLabs specimens, FromLabs showed statistically significantly less volume loss (p < 0.001). No other group pairs differed significantly from one another in terms of volume loss (p > 0.06). CONCLUSION 3D-printed denture teeth showed comparable strength and wear resistance with the prefabricated denture teeth and were suitable for long-term clinical usage except for NextDent that significantly showed the lowest fracture resistance.
Collapse
Affiliation(s)
- Mohammed M. Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Saudi Arabia
| | - Haidar Alalawi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Saudi Arabia
| | - Raghad Al-Ghamdi
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Saudi Arabia
| | - Rahaf Alghamdi
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Saudi Arabia
| | - Alaa Al-Jefri
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Saudi Arabia
| | - Faisal D. Al-Qarni
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Saudi Arabia
| |
Collapse
|
84
|
Qiu J, Liu W, Wu D, Qiao F, Sui L. Fit accuracy in the rest region of RPDs fabricated by digital technologies and conventional lost-wax casting: a systematic review and meta-analysis. BMC Oral Health 2023; 23:667. [PMID: 37715159 PMCID: PMC10504730 DOI: 10.1186/s12903-023-03348-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Accepted: 08/24/2023] [Indexed: 09/17/2023] Open
Abstract
BACKGROUND Digital technologies have recently been introduced into the fabrication of removable partial dentures (RPDs). However, it is still unclear whether the digitally fabricated RPDs fit better than conventionally cast ones in the rest region. The aim of this study was to evaluate the fit accuracy in the rest region of RPDs fabricated by digital technologies and compare it to those made by conventional lost-wax (CLW) technique. METHODS A comprehensive search was conducted in Cochrane Library, PubMed, EMbase, Web of Science and SpringerLink. Studies published up to August 2022 were collected. Two authors analyzed the studies independently and assessed the risk of bias on the modified methodological index for non-randomized studies (MINORS) scale. The mean values of gap distance between rests and corresponding rest seats of each study were extracted as outcome. A random-effects model at a significance level of P < 0.05 was used in the global comparison and subgroup analysis was carried out. RESULTS Overall, 11 articles out of 1214 complied with the inclusion criteria and were selected, including 2 randomized controlled trials (RCTs), 1 non-randomized clinical trial and 8 in vitro studies. Quantitative data from Meta-analysis revealed that fit accuracy in the rest region of RPDs fabricated with CLW showed no statistically significant difference with digital techniques (SMD = 0.33, 95%CI (-0.18, 0.83), P = 0.21). Subgroup analysis revealed a significantly better fit accuracy of CLW-fabricated RPDs in the rest region than either additive manufacturing (AM) groups or indirect groups (P = 0.03, P = 0.00), in which wax or resin patterns are milled or printed before conventional casting. While milled RPDs fit significantly better than cast ones in the rest region (P = 0.00). With digital relief and heat treatment, hybrid manufactured (HM) clasps obtained better fit accuracy in the rest region (P < 0.05). In addition, finishing and polishing procedure had no significant influence in the fit accuracy in all groups (P = 0.83). CONCLUSIONS RPDs fabricated by digital technologies exhibit comparable fit accuracy in rest region with those made by CLW. Digital technologies may be a promising alternative to CLW for the fabrication of RPDs and additional studies are recommended to provide stronger evidence. TRIAL REGISTRATION CRD42020201313.
Collapse
Affiliation(s)
- Jiachao Qiu
- Department of Prosthodontics, Tianjin Medical University School and Hospital of Stomatology, Qixiangtai Road No.12, Tianjin, 300070, P.R. China
| | - Wei Liu
- Department of Stomatology, North Sichuan Medical College, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, People's Republic of China
| | - Danfeng Wu
- Department of Prosthodontics, Tianjin Medical University School and Hospital of Stomatology, Qixiangtai Road No.12, Tianjin, 300070, P.R. China
| | - Feng Qiao
- Department of Oral and Maxillofacial Surgery, Tianjin Medical University School and Hospital of Stomatology, Qixiangtai Road No.12, Tianjin, 300070, P.R. China
| | - Lei Sui
- Department of Prosthodontics, Tianjin Medical University School and Hospital of Stomatology, Qixiangtai Road No.12, Tianjin, 300070, P.R. China.
| |
Collapse
|
85
|
Osnes C, Davda K, Hyde TP, Khalid S, Dillon S, Archer N, Attrill D, Devlin H, Keeling A. Current challenges for 3D printing complete dentures: experiences from a multi-centre clinical trial. Br Dent J 2023:10.1038/s41415-023-6114-0. [PMID: 37558770 DOI: 10.1038/s41415-023-6114-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 03/29/2023] [Accepted: 04/10/2023] [Indexed: 08/11/2023]
Abstract
Aims To develop an optimal clinical and laboratory protocol for the fabrication of 3D printing dentures.Design A prospective feasibility study across three UK dental schools.Material and methods Each patient received one conventional and one 3D-printed denture. Both dentures were constructed using the same impression, jaw registration and wax trial denture. Variables investigated included methods of digitisation of the impression and optional use of a 3D-printed baseplate for jaw registration.Results Clinicians strongly preferred 3D-printed baseplates. Patients felt that conventional and printed dentures were similar in retention and stability. More patients favoured conventional dentures over 3D-printed dentures in terms of comfort.Discussion It is feasible to combine conventional clinical work with digital techniques to produce 3D-printed dentures. 3D-printed baseplates offer a cost-effective alternative to conventional bases at the jaw registration stage. Challenges were faced in tooth positioning and managing occlusion, particularly where roots required adjustment.Conclusion 3D printing is suitable for producing baseplates for jaw registration blocks and wax trial insertions. It is feasible to produce 3D-printed dentures using conventional clinical techniques for impressions, jaw registration and wax trial insertion. The workflow used in this study for 3D-printed dentures is not superior to conventional dentures. Further work is required.
Collapse
Affiliation(s)
| | | | - T Paul Hyde
- School of Dentistry, University of Leeds, UK
| | | | - Sean Dillon
- School of Dentistry, University of Leeds, UK
| | | | | | - Hugh Devlin
- School of Dentistry, University of Manchester, UK
| | | |
Collapse
|
86
|
Abreu JLBD, Hirata R, Witek L, Benalcazar Jalkh EB, Nayak VV, de Souza BM, Silva EMD. Manufacturing and characterization of a 3D printed lithium disilicate ceramic via robocasting: A pilot study. J Mech Behav Biomed Mater 2023; 143:105867. [PMID: 37163816 DOI: 10.1016/j.jmbbm.2023.105867] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 04/20/2023] [Accepted: 04/22/2023] [Indexed: 05/12/2023]
Abstract
OBJECTIVE The objective of this study was to manufacture and to evaluate the physico-mechanical properties of the Lithium disilicate (Li2O5Si2) ceramic structures fabricated using additive manufacturing (3D printing). METHODS Li2O5Si2 samples were divided into (n = 30/group): SM (subtractively manufactured) and AR (additive/robocasting). For the AR group, Li2O5Si2 powder was combined with ammonium polyacrylate, hydroxypropyl methylcellulose, and polyelectrolyte to create a colloidal gel, which was then used for printing. A digital CAD model of a disc was designed, and the G-code transferred to a custom built DIW 3D printer. The control group samples were prepared using pre-crystallized ceramic blocks, which were cut to obtain discs with same dimensions as the AR group. Disc-shaped specimens from both groups were crystallized at 840 °C. Mechanical properties were evaluated using biaxial flexural strength test (BFS) and Vickers hardness test. Representative fractographic images of the specimens were acquired using scanning electron microscopy (SEM) to analyze the fracture origin and crack propagation. Energy-dispersive X-ray spectroscopy (EDS) and attenuated total reflection Fourier transform infrared spectroscopy (FTIR-ATR) were used for chemical analysis, and X-ray diffractometry (XRD) was performed to analyze the crystalline phases. RESULTS AR group yielded lower values of BFS (120.02 MPa ±33.91) and hardness (4.07 GPa ±0.30), relative to the SM group, (325.09 MPa ±63.98) and (5.63 GPa ±0.14), respectively. For EDS analysis, AR and SM groups showed similar elemental composition. In FTIR-ATR analysis, higher peaks referring to the crystalline structure were found for SM group. XRD analysis indicated a decreased formation of Li2O5Si2 from Lithium metasilicate (Li2O-SiO2) in the AM group. SEM micrographs showed a more porous microstructure associated with the 3D printed samples. SIGNIFICANCE The viability of fabricating Li2O5Si2 ceramic constructs using the Robocasting technique was successful. However, the samples prepared using subtractive manufacturing presented higher mechanical properties compared to the 3D printed constructs. The difference in properties between the manufacturing may be correlated to the decreased formation of Li2O5Si2 crystals and higher degrees of porosity.
Collapse
Affiliation(s)
- João Luiz Bittencourt de Abreu
- Department of Dental Clinic, School of Dentistry, Federal University of Rio de Janeiro, R. Prof. Rodolpho Paulo Rocco, 325, 21941617, Rio de Janeiro, RJ, Brazil; Analytical Laboratory of Restorative Biomaterials - LABiom-R, Universidade Federal Fluminense, School of Dentistry, Rua Mário Santos Braga, 30, 24020140, Niterói, Rio de Janeiro, Brazil; Biomaterials Division, NYU College of Dentistry, New York, NY, USA.
| | - Ronaldo Hirata
- Biomaterials Division, NYU College of Dentistry, New York, NY, USA.
| | - Lukasz Witek
- Biomaterials Division, NYU College of Dentistry, New York, NY, USA; Department of Biomedical Engineering, New York University Tandon School of Engineering, Brooklyn, NY, USA; Hansjörg Wyss Department of Plastic Surgery, NYU Grossman School of Medicine, New York, NY, USA.
| | - Ernesto Byron Benalcazar Jalkh
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Bauru, SP, Brazil.
| | - Vasudev Vivekanand Nayak
- Department of Mechanical and Aerospace Engineering, New York University Tandon School of Engineering, Brooklyn, NY, USA; Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL, USA.
| | - Bruno Martins de Souza
- Laboratory of Biomaterials, Military Engineering Institute, Rio de Janeiro, Rio de Janeiro, Brazil. Pç General Tibúrcio, 80, Rio de Janeiro, RJ, Brazil
| | - Eduardo Moreira da Silva
- Analytical Laboratory of Restorative Biomaterials - LABiom-R, Universidade Federal Fluminense, School of Dentistry, Rua Mário Santos Braga, 30, 24020140, Niterói, Rio de Janeiro, Brazil.
| |
Collapse
|
87
|
Igreţ A, Rotar RN, Ille C, Topală F, Jivănescu A. Marginal fit of milled versus different 3D-printed materials for provisional fixed dental prostheses: an in vitro comparative study. Med Pharm Rep 2023; 96:298-304. [PMID: 37577020 PMCID: PMC10419681 DOI: 10.15386/mpr-2588] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 01/09/2023] [Accepted: 02/09/2023] [Indexed: 08/15/2023] Open
Abstract
Introduction Provisional dental prostheses are used as interim restorations to help patients perform oral functions between the time of tooth preparation and the placement of the final restoration. A provisional dental prosthesis should protect the abutment from pulpal and gingival aggressions, adapt correctly to keep healthy gingival tissues, be durable, and have a low price. The purpose of this in vitro study was to compare the marginal adaptation of different types of provisional fixed dental prostheses (PFDP), fabricated using 3D printing technology versus the milling (computer-aided manufacturing [CAM]) technique. Method Two resin teeth (second premolar and second molar) on a typodont were prepared for three-unit provisional fixed dental prostheses. Thirty models were 3D-printed after a digital model was created using an intraoral scanner. Then, 30 provisional fixed dental prostheses (PFDPs) were made from a variety of materials using a digital design of a 3-unit PFDP and STL files delivered to a milling machine and a 3D printer, respectively. Ten PFDP were milled (CAM), and two sets of ten each, were fabricated with 3D printing technology (stereolithography), using two different materials. All restorations were analyzed under a microscope, and marginal gap was then measured using the software Image J. Results The milled group presented the best marginal gap values (ranging from 86 to 108 μm) and a median value of 93 μm, followed by GC group with (110-251 μm) with a median value of 205 μm and the PR group with median value of 316.5 μm. Conclusion According to the findings of this in vitro study, the milling (CAM) technique and SLA technology provides acceptable marginal fit values to fabricate provisional fixed partial dentures.
Collapse
Affiliation(s)
- Anca Igreţ
- Department of Prosthodontics, Faculty of Dentistry, Victor Babeş University of Medicine and Pharmacy, Timişoara, Romania
| | - Raul Nicolae Rotar
- Department of Prosthodontics, Faculty of Dentistry, Victor Babeş University of Medicine and Pharmacy, Timişoara, Romania
- TADERP Research Center, UMFVBT, Timişoara, Romania
| | - Codruţa Ille
- Department of Prosthodontics, Faculty of Dentistry, Victor Babeş University of Medicine and Pharmacy, Timişoara, Romania
- TADERP Research Center, UMFVBT, Timişoara, Romania
| | - Florin Topală
- Department of Prosthodontics, Faculty of Dentistry, Victor Babeş University of Medicine and Pharmacy, Timişoara, Romania
| | - Anca Jivănescu
- Department of Prosthodontics, Faculty of Dentistry, Victor Babeş University of Medicine and Pharmacy, Timişoara, Romania
- TADERP Research Center, UMFVBT, Timişoara, Romania
| |
Collapse
|
88
|
Zheng H, Xia Y, Ni X, Wu J, Li Y, Zhang P, Wu X, Lu K, Zhao Q. Clinical effects of 3D printing-assisted posterolateral incision in the treatment of ankle fractures involving the posterior malleolus. Front Surg 2023; 10:1176254. [PMID: 37292486 PMCID: PMC10244554 DOI: 10.3389/fsurg.2023.1176254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 05/03/2023] [Indexed: 06/10/2023] Open
Abstract
Objective To explore the clinical outcomes of a 3D printing-assisted posterolateral approach for the treatment of ankle fractures involving the posterior malleolus. Methods A total of 51 patients with ankle fractures involving the posterior malleolus admitted to our hospital from January 2018 to December 2019 were selected. The patients were divided into 3D printing group (28 cases) and control group (23 cases). 3D printing was performed for ankle fractures, followed by printing of a solid model and simulation of the operation on the 3D model. The operation was then performed according to the preoperative plan, including open reduction and internal fixation via the posterolateral approach with the patient in the prone position. Routine x-ray and CT examinations of the ankle joint were performed, and ankle function was evaluated using the American Foot and Ankle Surgery Association (AOFAS) ankle-hindfoot score. Results All patients underwent x-ray and CT examinations. All fractures healed clinically, without loss of reduction or failure of internal fixation. Good clinical effects were achieved in both groups of patients. The operation time, intraoperative blood loss and intraoperative fluoroscopy frequency in the 3D printing group were significantly less than those in the control group (p < 0.05). There was no significant difference between the two groups in the anatomical reduction rate of fractures or the incidence of surgical complications (p > 0.05). Conclusion The 3D printing-assisted posterolateral approach is effective in the treatment of ankle fractures involving the posterior malleolus. The approach can be well planned before the operation, is simple to perform, yields good fracture reduction and fixation, and has good prospects for clinical application.
Collapse
Affiliation(s)
- Hongming Zheng
- Department of Orthopedic Surgery, Affiliated Danyang Hospital of Nantong University, Danyang, China
| | - Yan Xia
- Department of Orthopedic Surgery, Affiliated Danyang Hospital of Nantong University, Danyang, China
| | - Xiaohui Ni
- Department of Orthopedics, Dafeng People’s Hospital, Yancheng, China
| | - Jieshi Wu
- Department of Orthopaedics, Affiliated Hospital of Jiangnan University, Wuxi, China
| | - Yankun Li
- Department of Orthopaedics, Guizhou Provincial People's Hospital, Guiyang, China
| | - Pengpeng Zhang
- Department of Orthopaedics, Guizhou Provincial People's Hospital, Guiyang, China
| | - Xinglin Wu
- Department of Orthopaedics, Guizhou Provincial People's Hospital, Guiyang, China
| | - Kaihang Lu
- Department of Orthopaedics, Guizhou Provincial People's Hospital, Guiyang, China
| | - Quanming Zhao
- Department of Orthopaedics, Guizhou Provincial People's Hospital, Guiyang, China
| |
Collapse
|
89
|
Da Silva TM, Immich F, De Araujo TS, Lund RG, Da Silva AF, Piva E, Da Rosa WLDO. Photosensitive resins used in additive manufacturing for oral application in dentistry: A scoping review from lab to clinic. J Mech Behav Biomed Mater 2023; 141:105732. [PMID: 36898354 DOI: 10.1016/j.jmbbm.2023.105732] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 01/21/2023] [Accepted: 02/11/2023] [Indexed: 03/05/2023]
Affiliation(s)
| | - Felipe Immich
- School of Dentistry, Federal University of Pelotas, RS, Brazil.
| | | | - Rafael Guerra Lund
- Department of Restorative Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil.
| | - Adriana Fernandes Da Silva
- Department of Restorative Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil.
| | - Evandro Piva
- Department of Restorative Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil.
| | | |
Collapse
|
90
|
Juri AZ, Belli R, Lohbauer U, Ebendorff-Heidepriem H, Yin L. Edge chipping damage in lithium silicate glass-ceramics induced by conventional and ultrasonic vibration-assisted diamond machining. Dent Mater 2023:S0109-5641(23)00091-X. [PMID: 37076403 DOI: 10.1016/j.dental.2023.04.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 03/30/2023] [Accepted: 04/05/2023] [Indexed: 04/21/2023]
Abstract
OBJECTIVES Diamond machining of lithium silicate glass-ceramics (LS) induces extensive edge chipping damage, detrimentally affecting LS restoration functionality and long-term performance. This study approached novel ultrasonic vibration-assisted machining of pre-crystallized and crystallized LS materials to investigate induced edge chipping damage in comparison with conventional machining. METHODS The vibration-assisted diamond machining was conducted using a five-axis ultrasonic high-speed grinding/machining machine at different vibration amplitudes while conventional machining was performed using the same machine without vibration assistance. LS microstructural characterization and phase development were performed using scanning electron microscopy (SEM) and x-ray diffraction (XRD) techniques. Machining-induced edge chipping depths, areas and morphology were also characterized using the SEM and Java-based imaging software. RESULTS All machining-induced edge chipping damages resulted from brittle fractures. The damage scales, however, depended on the material microstructures; mechanical properties associated with the fracture toughness, critical strain energy release rates, brittleness indices, and machinability indices; and ultrasonic vibration amplitudes. Pre-crystallized LS with more glass matrix and lithium metasilicate crystals yielded respective 1.8 and 1.6 times greater damage depths and specific damage areas than crystallized LS with less glass matrix and tri-crystal phases in conventional machining. Ultrasonic machining at optimized amplitudes diminished such damages by over 50 % in pre-crystallized LS and up to 13 % in crystallized LS. SIGNIFICANCE This research highlights that ultrasonic vibration assistance at optimized conditions may advance current dental CAD/CAM machining techniques by significant suppression of edge chipping damage in pre-crystallized LS.
Collapse
Affiliation(s)
- Afifah Z Juri
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide 5005, SA, Australia.
| | - Renan Belli
- Research Laboratory for Dental Biomaterials, Dental Clinic 1 - Operative Dentistry and Periodontology, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Ulrich Lohbauer
- Research Laboratory for Dental Biomaterials, Dental Clinic 1 - Operative Dentistry and Periodontology, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Heike Ebendorff-Heidepriem
- Institute for Photonics and Advanced Sensing (IPAS) and School of Physics, Chemistry and Earth Sciences, The University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Ling Yin
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide 5005, SA, Australia.
| |
Collapse
|
91
|
Balhaddad AA, Garcia IM, Mokeem L, Alsahafi R, Majeed-Saidan A, Albagami HH, Khan AS, Ahmad S, Collares FM, Della Bona A, Melo MAS. Three-dimensional (3D) printing in dental practice: Applications, areas of interest, and level of evidence. Clin Oral Investig 2023:10.1007/s00784-023-04983-7. [PMID: 37017759 DOI: 10.1007/s00784-023-04983-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 03/28/2023] [Indexed: 04/06/2023]
Abstract
OBJECTIVES The aim of this review to overview three-dimensional (3D) printing technologies available for different dental disciplines, considering the applicability of such technologies and materials development. MATERIALS AND METHODS Source Arksey and O'Malley's five stages framework using PubMed, EMBASE, and Scopus (Elsevier) databases managed this review. Papers focusing on 3D printing in dentistry and written in English were screened. Scientific productivity by the number of publications, areas of interest, and the focus of the investigations in each dental discipline were extracted. RESULTS Nine hundred thirty-four studies using 3D printing in dentistry were assessed. Limited clinical trials were observed, especially in Restorative, endodontics, and pediatric dentistry. Laboratory or animal studies are not reliable for clinical success, suggesting that clinical trials are a good approach to validate the new methods' outcomes and ensure that the benefits outweigh the risk. The most common application for 3D printing technologies is to facilitate conventional dental procedures. CONCLUSIONS The constantly improving quality of 3D printing applications has contributed to increasing the popularity of these technologies in dentistry; however, long-term clinical studies are necessary to assist in defining standards and endorsing the safe application of 3D printing in dental practice. CLINICAL RELEVANCE The recent progress in 3D materials has improved dental practice capabilities over the last decade. Understanding the current status of 3D printing in dentistry is essential to facilitate translating its applications from laboratory to the clinical setting.
Collapse
Affiliation(s)
- Abdulrahman A Balhaddad
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O.Box 1982, Dammam, 31441, Saudi Arabia.
| | - Isadora Martini Garcia
- Clinical Assistant Professor, Division of Operative Dentistry, Department of General Dentistry, University of Maryland School of Dentistry, Baltimore, MD, 21201, USA
| | - Lamia Mokeem
- Ph.D. Program in Dental Biomedical Sciences, University of Maryland School of Dentistry, Baltimore, Maryland, USA
| | - Rashed Alsahafi
- Department of Restorative Dental Sciences, College of Dentistry, Umm Al-Qura University, Makkah, 24381, Saudi Arabia
| | - Ahmad Majeed-Saidan
- Division of Prosthodontics, Department of Advanced Oral Sciences and Therapeutics, University of Maryland School of Dentistry, Baltimore, MD, 21201, USA
| | - Hathal H Albagami
- Department of Restorative Dental Sciences, College of Dentistry, Taibah University, Medina, 42353, Saudi Arabia
| | - Abdul Samad Khan
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O.Box 1982, Dammam, 31441, Saudi Arabia
| | - Shakil Ahmad
- Directorate of Library Affairs, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31441, Kingdom of Saudi Arabia
| | - Fabricio Mezzomo Collares
- Department of Dental Materials, School of Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| | - Alvaro Della Bona
- Postgraduate Program in Dentistry, Dental School, University of Passo Fundo, Passo Fundo, Brazil
| | - Mary Anne S Melo
- Ph.D. Program in Dental Biomedical Sciences, University of Maryland School of Dentistry, Baltimore, Maryland, USA.
- Division of Operative Dentistry, Department of General Dentistry, University of Maryland School of Dentistry, Baltimore, Maryland, USA.
| |
Collapse
|
92
|
Lee J, Ju S, Kim J, Hwang S, Ahn J. The comparison of the accuracy of temporary crowns fabricated with several 3D printers and a milling machine. J Adv Prosthodont 2023; 15:72-79. [PMID: 37153009 PMCID: PMC10154143 DOI: 10.4047/jap.2023.15.2.72] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 04/08/2023] [Accepted: 04/21/2023] [Indexed: 05/09/2023] Open
Abstract
PURPOSE The purpose of this in vitro study was to compare the accuracy of various 3D printers and a milling machine. MATERIALS AND METHODS The die model was designed using CAD (Autodesk Inventor 2018 sp3). The 30 µm cement space was given to the die and the ideal crown of the mandibular left first molar was designed using CAD (ExoCAD). The crowns were produced using the milling machine (Imes-icore 250i) and the 3D printers (Zenith U, Zenith D, W11) and they were divided into four groups. In all groups, the interior of each crown was scanned (Identica blue) and superimposed (Geomagic Control X) with the previously designed die. The difference between the die and the actual crown was measured at specific points. The Kruskal-Wallis test, the Mann-Whitney test, and Bonferroni's method were performed with a statistical analysis software (P < .008 in inter-group comparison P < .001 in intra-group comparison). RESULTS In all groups, the center of the occlusal area and the anti-rotational dimple area showed significantly greater difference and the marginal area showed the smallest difference comparatively. The mean value of the difference in each area and the sum of the differences were higher in order of W11, Imes-icore 250i, Zenith D, and Zenith U. CONCLUSION The digital light processing (DLP) method shows higher accuracy compared to the sereolithography (SLA) method using the same resin material.
Collapse
Affiliation(s)
- Junsik Lee
- Dental Research Institute and Department of Dental Biomaterials Science, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Sungwon Ju
- Dental Research Institute and Department of Dental Biomaterials Science, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | | | - Sion Hwang
- Dental Research Institute and Department of Dental Biomaterials Science, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Jinsoo Ahn
- Dental Research Institute and Department of Dental Biomaterials Science, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| |
Collapse
|
93
|
Espinar C, Bona AD, Pérez MM, Tejada-Casado M, Pulgar R. The influence of printing angle on color and translucency of 3D printed resins for dental restorations. Dent Mater 2023; 39:410-417. [PMID: 36914433 DOI: 10.1016/j.dental.2023.03.011] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 02/06/2023] [Accepted: 03/03/2023] [Indexed: 03/13/2023]
Abstract
OBJECTIVES To evaluate the influence of printing orientation on color and translucency of 3D printing restorative resins. METHODS Four 3D printing resin systems in the available shades (DFT-Detax Freeprint Temp- A1, A2,A3; FP-Formlabs Permanent Crown- A2,A3,B1,C2; FT- Formlabs Temporary CB- A2,A3,B1,C2; GCT-GC Temporary- Light, Medium) were evaluated. Three samples (10×10×1.2 mm) from each material were printed at two different printing orientations (0° and 90°) and polished to 1.00 ± 0,01 mm of thickness. Spectral reflectance was measured against black background using a calibrated spectroradiometer, CIE D65 standard illuminant and the 45°/0°geometry. Color and translucency differences were evaluated using CIEDE2000 metric (ΔE00) and 50:50% perceptibility (PT00 and TPT00) and acceptability (AT00 and TAT00) thresholds. RESULTS In general, color changes due to printing orientation at (0° and 90°) were mainly produced by ΔL* or ΔC* . ΔE00 were above PT00 for all DFT shades, FP-B1, FP-C2, FT-A2 and FT-B1. Only for DFT-1, ΔE00 was above AT00. ΔRTP00 values were above TPT00 for DFT-A1, DFT-A3, FP-B1 and FT-B1, but lower than TAT00. The direction of the changes in translucency (ΔRTP00) depends on the material and shade. SIGNIFICANCE The selection of building orientation (0° and 90°) for the 3D printed resins influence the visual color and translucency and therefore their esthetic appearance. These aspects should be considered when printing dental restorations using the evaluated materials.
Collapse
Affiliation(s)
- Cristina Espinar
- Department of Stomatology, Faculty of Dentistry, Colegio Máximo, University of Granada, Campus de Cartuja s/n, 18071 Granada, Spain
| | - Alvaro Della Bona
- Post-Graduate Program in Dentistry, Dental School, University of Passo Fundo, Campus I, Passo Fundo, RS, Brazil
| | - María M Pérez
- Department of Optics, Faculty of Science, Campus Fuentenueva, University of Granada, Edificio Mecenas, s/n, 18071 Granada, Spain.
| | - Maria Tejada-Casado
- Department of Optics, Faculty of Science, Campus Fuentenueva, University of Granada, Edificio Mecenas, s/n, 18071 Granada, Spain
| | - Rosa Pulgar
- Department of Stomatology, Faculty of Dentistry, Colegio Máximo, University of Granada, Campus de Cartuja s/n, 18071 Granada, Spain
| |
Collapse
|
94
|
Sandmair MN, Kleber C, Ströbele DA, von See C. AFM Analysis of a Three-Point Flexure Tested, 3D Printing Definitive Restoration Material for Dentistry. J Funct Biomater 2023; 14:jfb14030152. [PMID: 36976076 PMCID: PMC10056548 DOI: 10.3390/jfb14030152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 02/28/2023] [Accepted: 03/07/2023] [Indexed: 03/12/2023] Open
Abstract
Background: Three-dimensional printing is a rapidly developing technology across all industries. In medicine recent developments include 3D bioprinting, personalized medication and custom prosthetics and implants. To ensure safety and long-term usability in a clinical setting, it is essential to understand material specific properties. This study aims to analyze possible surface changes of a commercially available and approved DLP 3D printed definitive restoration material for dentistry after three-point flexure testing. Furthermore, this study explores whether Atomic Force Microscopy (AFM) is a feasible method for examination of 3D printed dental materials in general. This is a pilot study, as there are currently no studies that analyze 3D printed dental materials using an AFM. Methods: The present study consisted of a pretest followed by the main test. The resulting break force of the preliminary test was used to determine the force used in the main test. The main test consisted of atomic force microscopy (AFM) surface analysis of the test specimen followed by a three-point flexure procedure. After bending, the same specimen was analyzed with the AFM again, to observe possible surface changes. Results: The mean root mean square (RMS) roughness of the segments with the most stress was 20.27 nm (±5.16) before bending, while it was 26.48 nm (±6.67) afterward. The corresponding mean roughness (Ra) values were 16.05 nm (±4.25) and 21.19 nm (±5.71) Conclusions: Under three-point flexure testing, the surface roughness increased significantly. The p-value for RMS roughness was p = 0.003, while it was p = 0.006 for Ra. Furthermore, this study showed that AFM surface analysis is a suitable procedure to investigate surface changes in 3D printed dental materials.
Collapse
Affiliation(s)
- Maximilian N. Sandmair
- Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, 3500 Krems, Austria
- Correspondence: (M.N.S.); (C.v.S.)
| | - Christoph Kleber
- Department of Medicine, Faculty of Medicine and Dentistry, Danube Private University, 3500 Krems, Austria
| | - Dragan A. Ströbele
- Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, 3500 Krems, Austria
| | - Constantin von See
- Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, 3500 Krems, Austria
- Correspondence: (M.N.S.); (C.v.S.)
| |
Collapse
|
95
|
Effect of Adhesion Conditions on the Shear Bond Strength of 3D Printing Resins after Thermocycling Used for Definitive Prosthesis. Polymers (Basel) 2023; 15:polym15061390. [PMID: 36987170 PMCID: PMC10056338 DOI: 10.3390/polym15061390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 03/08/2023] [Accepted: 03/09/2023] [Indexed: 03/12/2023] Open
Abstract
Three-dimensional (3D) printing polymers such as urethane dimethacrylate (UDMA) and ethoxylated bisphenol A dimethacrylate (Bis-EMA) are typically used in definitive prosthesis and require surface treatments before bonding. However, surface treatment and adhesion conditions often affect long-term use. Herein, polymers were divided into Groups 1 and 2 for the UDMA and Bis-EMA components, respectively. The shear bond strength (SBS) between two types of 3D printing resins and resin cements was measured using Rely X Ultimate Cement and Rely X U200, according to adhesion conditions such as single bond universal (SBU) and airborne-particle abrasion (APA) treatments. Thermocycling was performed to evaluate the long-term stability. Sample surface changes were observed using a scanning electron microscope and surface roughness measuring instrument. The effect of interaction between the resin material and adhesion conditions on the SBS was analyzed via a two-way analysis of variance. The optimal adhesion condition for Group 1 was achieved when U200 was used after APA and SBU, whereas Group 2 was not significantly affected by the adhesion conditions. After thermocycling, the SBS significantly decreased in Group 1 without APA treatment and in the entire Group 2. Additionally, porosity, along with increased roughness, was observed on both material surfaces after APA.
Collapse
|
96
|
Rues S, Zehender N, Zenthöfer A, Bömicke W, Herpel C, Ilani A, Erber R, Roser C, Lux CJ, Rammelsberg P, Schwindling FS. Fit of anterior restorations made of 3D-printed and milled zirconia: An in-vitro study. J Dent 2023; 130:104415. [PMID: 36640843 DOI: 10.1016/j.jdent.2023.104415] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 12/23/2022] [Accepted: 01/10/2023] [Indexed: 01/13/2023] Open
Abstract
OBJECTIVES To evaluate the fit of zirconia veneers made by either 3D printing or milling. METHODS A typodont maxillary central incisor was prepared for a 0.5-mm-thick veneer and was reproduced 36 times from resin. Restorations were designed with a 20-µm-wide marginal and a 60-µm-wide internal cement gap, and were made from 3D-printed zirconia (LithaCon 3Y 210, Lithoz, n = 24) and milled zirconia (Cercon ht, DentsplySirona, n = 12). For milled zirconia, a drill compensation was needed to give the milling bur access to the intaglio surface. The restorations were cemented, cross-sectioned, and the cement gap size was analyzed by two raters. Inter-rater reliability was studied at 12 3D-printed veneers (intraclass correlation coefficient, ICC, mixed model, absolute agreement). Twelve remaining 3D-printed restorations were compared with 12 milled restorations regarding fit at three locations: marginally, labially, and at the incisal edge (Mann-Whitney U-tests, α<0.05). RESULTS Inter-rater reliability was excellent, with an ICC single-measure coefficient of 0.944 (95%-confidence interval: [0.907; 0.966]). Gap sizes (mean ± SD / maximum) were 55 ± 9 / 143 µm at the margins, 68 ± 14 / 130 µm labially, and 78 ± 19 / 176 µm at the incisor edge for 3D-printed veneers. For milled veneers, gap sizes were 44 ± 11 / 141 µm at the margins, 85 ± 19 / 171 µm labially, and 391 ± 26 / 477 µm at the incisor edge. At the margins, the milled veneers outperformed the 3D-printed restorations (p = 0.011). The cement gap at the incisor edge was significantly smaller after 3D printing (p < 0.001). CONCLUSIONS 3D-printed zirconia restorations showed clinically acceptable mean marginal gaps below 100 µm. Because drill compensation could be omitted with 3D printing, the fit at the sharp incisal edge was significantly tighter than with milling. CLINICAL SIGNIFICANCE The fit of 3D-printed ceramic anterior restorations meets clinical standards. In addition, 3D printing is associated with a greater geometrical freedom than milling. With regard to fit this feature allows tighter adaptation even after minimally invasive preparation.
Collapse
Affiliation(s)
- Stefan Rues
- Department of Prosthodontics, Heidelberg University Hospital, Heidelberg, Germany
| | - Nathalie Zehender
- Department of Prosthodontics, Heidelberg University Hospital, Heidelberg, Germany
| | - Andreas Zenthöfer
- Department of Prosthodontics, Heidelberg University Hospital, Heidelberg, Germany
| | - Wolfgang Bömicke
- Department of Prosthodontics, Heidelberg University Hospital, Heidelberg, Germany
| | - Christopher Herpel
- Department of Prosthodontics, Heidelberg University Hospital, Heidelberg, Germany
| | - Ali Ilani
- Department of Prosthodontics, Heidelberg University Hospital, Heidelberg, Germany
| | - Ralf Erber
- Department of Orthodontics, Heidelberg University Hospital, Heidelberg, Germany
| | - Christoph Roser
- Department of Orthodontics, Heidelberg University Hospital, Heidelberg, Germany
| | - Christopher J Lux
- Department of Orthodontics, Heidelberg University Hospital, Heidelberg, Germany
| | - Peter Rammelsberg
- Department of Prosthodontics, Heidelberg University Hospital, Heidelberg, Germany
| | | |
Collapse
|
97
|
Trzaskowski M, Mańka-Malara K, Szczesio-Włodarczyk A, Sokołowski J, Kostrzewa-Janicka J, Mierzwińska-Nastalska E. Evaluation of Mechanical Properties of 3D-Printed Polymeric Materials for Possible Application in Mouthguards. Polymers (Basel) 2023; 15:898. [PMID: 36850182 PMCID: PMC9964375 DOI: 10.3390/polym15040898] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 02/05/2023] [Accepted: 02/09/2023] [Indexed: 02/16/2023] Open
Abstract
Custom mouthguards are used in various sports disciplines as a protection for teeth, temporomandibular joints, and soft tissues of the oral cavity from impact forces. The purpose of this research was to evaluate the mechanical properties of flexible polymeric 3D-printable materials and to select a material with the most favourable physical properties for making intraoral protectors. Four 3D-printable polymeric materials were selected for the evaluation: IMPRIMO LC IBT (Scheu-Dental, Iserlohn, Germany), Keyortho IBT (EnvisionTEC, Gladbeck, Germany), IBT (Formlabs, Somerville, MA, USA), and Ortho IBT (NextDent, Utrecht, Netherlands). A total of 176 samples (44 from each material) was 3D-printed using the stereolitography (SLA) technique. Tensile strength, flexural strength, notch-toughness, Shore hardness, sorption, and solubility tests were conducted. The materials were compared using a series of analyses of variance (one-way ANOVA) with Bonferroni post hoc tests. Statistical analyses were performed with the use of IBM SPSS Statistics 28.0.0 software (IBM, New York, NY, USA). Each material was assigned a score from 1 to 4 depending on the individual test results, and tests were given indexes according to the significance of the parameter in the mouthguard protective function. The number of points obtained by each material in each test was then multiplied by the test index, and the results were tabulated. The material with the highest result among the ones studied-most suitable for the application in mouthguard fabrication-was Keyortho IBT from EnvisionTEC.
Collapse
Affiliation(s)
- Maciej Trzaskowski
- Department of Prosthodontics, Medical University of Warsaw, ul. Binieckiego 6, 02-097 Warsaw, Poland
| | - Katarzyna Mańka-Malara
- Department of Prosthodontics, Medical University of Warsaw, ul. Binieckiego 6, 02-097 Warsaw, Poland
| | - Agata Szczesio-Włodarczyk
- University Laboratory of Materials Research, Medical University of Lodz, Pomorska 251, 92-216 Łódź, Poland
| | - Jerzy Sokołowski
- University Laboratory of Materials Research, Medical University of Lodz, Pomorska 251, 92-216 Łódź, Poland
| | - Jolanta Kostrzewa-Janicka
- Department of Prosthodontics, Medical University of Warsaw, ul. Binieckiego 6, 02-097 Warsaw, Poland
| | | |
Collapse
|
98
|
Monitoring the Calibration of In-Office 3D Printers. Dent J (Basel) 2023; 11:dj11010020. [PMID: 36661556 PMCID: PMC9858488 DOI: 10.3390/dj11010020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 12/15/2022] [Accepted: 12/26/2022] [Indexed: 01/06/2023] Open
Abstract
Most desktop 3D printers lack features that allow manual calibration of printer parameters. It is crucial to assess the accuracy of printing to minimize the margin of error and variance between each print. Therefore, this study aimed to develop a method for monitoring the calibration of in-office 3D printers. A calibration coupon was designed to have a tolerance and dimensions that define nominal geometry and allow the measurement of variances occurring in X−Y axes and curvature. Ten printing cycles were run on two stereolithography (SLA) 3D printers with two different resins. Additionally, the coupons were positioned in five positions on the build platform to assess errors caused by differences in positioning. Measurements were made on the X and Y axes. No statistical difference was noted between the coupons being printed in different positions on the build platform and between the two resins at both X and Y axes of measurement (p > 0.05). Desktop 3D printers currently lack a standardized calibration protocol, which provides a closed loop for design and manufacturing of printed parts. The coupon in this study will allow monitoring the calibration of desktop 3D printers to ensure high-quality printing.
Collapse
|
99
|
Bonfante EA, Calamita M, Bergamo ETP. Indirect restorative systems-A narrative review. J ESTHET RESTOR DENT 2023; 35:84-104. [PMID: 36688803 DOI: 10.1111/jerd.13016] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 01/03/2023] [Accepted: 01/04/2023] [Indexed: 01/24/2023]
Abstract
OBJECTIVE The background and clinical understanding of the properties of currently available indirect restorative systems and fabrication methods is, along with manufacturer and evidence-based literature, an important starting point to guide the clinical selection of materials for tooth and/or implant supported reconstructions. Therefore, this review explores most indirect restorative systems available in the market, especially all-ceramic, along with aspects of manufacturing process, clinical survival rates, and esthetic outcomes. OVERVIEW Progressive incorporation of new technologies in the dental field and advancements in materials science have enabled the development/improvement of indirect restorative systems and treatment concepts in oral rehabilitation, resulting in reliable and predictable workflows and successful esthetic and functional outcomes. Indirect restorative systems have evolved from metal ceramics and polymers to glass ceramics, polycrystalline ceramics, and resin-matrix ceramics, aiming to improve not only biological and mechanical properties, but especially the optical properties and esthetic quality of the reconstructions, in attempt to mimic natural teeth. CONCLUSIONS Based on several clinical research, materials, and patient-related parameters, a decision tree for the selection of indirect restorative materials was suggested to guide clinicians in the rehabilitation process. CLINICAL SIGNIFICANCE The pace of materials development is faster than that of clinical research aimed to support their use. Since no single material provides an ideal solution to every case, professionals must continuously seek information from well designed, long-term clinical trials in order to incorporate or not new materials and technological advancements.
Collapse
Affiliation(s)
- Estevam A Bonfante
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry - University of São Paulo, Bauru, SP, Brazil
| | - Marcelo Calamita
- Department of Restorative Dental Sciences at the University of Florida, Gainesville, Florida, USA
| | - Edmara T P Bergamo
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry - University of São Paulo, Bauru, SP, Brazil
| |
Collapse
|
100
|
Pacho MO, Deeney D, Johnson EA, Bravo BN, Patel K, Latta MA, Belshan MA, Gross SM. Characterization of Ag-Ion Releasing Zeolite Filled 3D Printed Resins. J Funct Biomater 2022; 14:jfb14010007. [PMID: 36662054 PMCID: PMC9861246 DOI: 10.3390/jfb14010007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 12/16/2022] [Accepted: 12/20/2022] [Indexed: 12/24/2022] Open
Abstract
There has been profound growth in the use of 3D printed materials in dentistry in general, including orthodontics. The opportunity to impart antimicrobial properties to 3D printed parts from existing resins requires the capability of forming a stable colloid incorporating antimicrobial fillers. The objective of this research was to characterize a colloid consisting of a 3D printable resin mixed with Ag-ion releasing zeolites and fumed silica to create 3D printed parts with antiviral properties. The final composite was tested for antiviral properties against SARS-CoV-2 and HIV-1. Antiviral activity was measured in terms of the half-life of SARS-CoV-2 and HIV-1 on the composite surface. The inclusion of the zeolite did not interfere with the kinetics measured on the surface of the ATR crystal. While the depth of cure, measured following ISO4049 guidelines, was reduced from 3.8 mm to 1.4 mm in 5 s, this greatly exceeded the resolution required for 3D printing. The colloid was stable for at least 6 months and the rheological behavior was dependent upon the fumed silica loading. The inclusion of zeolites and fumed silica significantly increased the flexural strength of the composite as measured by a 3 point bend test. The composite released approximately 2500 μg/L of silver ion per gram of composite as determined by potentiometry. There was a significant reduction of the average half-life of SARS-CoV-2 (1.9 fold) and HIV-1 (2.7 fold) on the surface of the composite. The inclusion of Ag-ion releasing zeolites into 3D-printable resin can result in stable colloids that generate composites with improved mechanical properties and antiviral properties.
Collapse
Affiliation(s)
- Marian O. Pacho
- Department of Oral Biology, School of Dentistry, Creighton University, Omaha, NE 68178, USA
| | - Dylan Deeney
- Department of Medical Microbiology and Immunology, Creighton University, Omaha, NE 68178, USA
| | - Emily A. Johnson
- Department of Oral Biology, School of Dentistry, Creighton University, Omaha, NE 68178, USA
| | - Bryanna N. Bravo
- Department of Chemistry, College of Arts and Sciences, Creighton University, Omaha, NE 68178, USA
| | - Kishen Patel
- Department of Chemistry, College of Arts and Sciences, Creighton University, Omaha, NE 68178, USA
| | - Mark A. Latta
- Department of Oral Biology, School of Dentistry, Creighton University, Omaha, NE 68178, USA
| | - Michael A. Belshan
- Department of Medical Microbiology and Immunology, Creighton University, Omaha, NE 68178, USA
| | - Stephen M. Gross
- Department of Oral Biology, School of Dentistry, Creighton University, Omaha, NE 68178, USA
- Department of Chemistry, College of Arts and Sciences, Creighton University, Omaha, NE 68178, USA
- Correspondence:
| |
Collapse
|