51
|
Johansson B, Sundelin S, Wikberg-Matsson A, Unsbo P, Behndig A. Visual and optical performance of the Akreos Adapt Advanced Optics and Tecnis Z9000 intraocular lenses: Swedish multicenter study. J Cataract Refract Surg 2007; 33:1565-72. [PMID: 17720071 DOI: 10.1016/j.jcrs.2007.05.025] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2007] [Accepted: 05/23/2007] [Indexed: 11/30/2022]
Abstract
PURPOSE To compare the subjective visual and objective optical performance of 2 aspherical intraocular lenses (IOLs), the Akreos Adapt Advanced Optics (AO) (Bausch & Lomb, Inc.) and the Tecnis Z9000 (Advanced Medical Optics, Inc.). SETTING Four university hospitals in Sweden. METHODS This study comprised 80 patients, 20 each from 4 university hospital centers in Sweden. All patients had bilateral clear corneal phacoemulsification with implantation of an Akreos Adapt AO IOL in 1 eye and Tecnis Z9000 IOL in the other eye according to a randomization protocol. Preoperatively, 90% contrast Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity was measured and the mesopic pupil sizes were determined. Ten to 12 weeks postoperatively, 12.5% and 90% contrast ETDRS visual acuities and photopic and mesopic Functional Acuity Contrast Test chart contrast sensitivities were determined. Wavefront analysis was performed with the Zywave II aberrometer (Bausch & Lomb, Inc.), and a questionnaire on the subjective quality of vision was completed by each patient. RESULTS The Akreos AO IOL and Tecnis Z9000 IOL produced similar high- and low-contrast visual acuities as well as photopic and mesopic contrast sensitivities. The Tecnis Z9000 IOL resulted in lower spherical aberrations of the eye (mean 0.05 +/- 0.13 microm versus 0.35 +/- 0.13 microm root mean square, 6.0 mm pupil) (P<.001); however, the Akreos AO IOL provided a larger depth of field (mean 1.22 diopter [D] +/- 0.48 [SD] versus 0.86 +/- 0.50 D, 6.0 mm pupil) (P<.001). Patient satisfaction was generally high, although 68.8% of the patients reported some type of visual disturbance postoperatively. Twenty-eight percent of patients reported better subjective visual quality in the Akreos AO eye and 14%, in the Tecnis Z9000 eye (P<.0001). Accordingly, 33% perceived more visual disturbances in the Tecnis Z9000 eye and 11%, in the Akreos AO eye (P<.0001). CONCLUSIONS Maximum reduction of spherical aberration did not maximize subjective visual quality. The higher perceived quality of vision with the Akreos AO IOL could be because of differences in depth of field, IOL material, or IOL design.
Collapse
Affiliation(s)
- Björn Johansson
- Division of Ophthalmology, Department of Neuroscience and Locomotion, Linköping University Hospital, Linköping, Sweden
| | | | | | | | | |
Collapse
|
52
|
Katayama Y, Kobayakawa S, Yanagawa H, Tochikubo T. The Relationship between the Adhesion Characteristics of Acrylic Intraocular Lens Materials and Posterior Capsule Opacification. Ophthalmic Res 2007; 39:276-81. [PMID: 17851268 DOI: 10.1159/000108121] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2006] [Accepted: 04/19/2007] [Indexed: 11/19/2022]
Abstract
PURPOSE To investigate the relationship between the adhesion characteristics of similarly designed hydrophobic acrylic intraocular lenses (IOLs) and posterior capsule opacification (PCO). METHODS Three similarly shaped hydrophobic acrylic IOLs with a sharp-edged optic were used. Adhesive force of IOLs was measured with a tackiness tester. Human lens epithelial cells (LECs) were grown on each IOL for 48 h. LECs were then stained with crystal violet, which served as an index of the amount of cells attached to IOLs. Cellular migration and proliferation assays were performed using chamber inserts containing a collagen membrane. After 96 h of incubation, the collagen membranes were stained with hematoxylin and eosin for analysis. Three similarly shaped IOLs were implanted in rabbits. The eyes were enucleated 3 weeks later and analyzed for PCO area. RESULTS Hydrophobic acrylic IOLs were classified into three groups: A (less adhesive), B (moderately) and C (highly). The migration area of LECs on the collagen membrane was 5.65 +/- 4.5% in group A, 2.83 +/- 2.1% in group B, and 1.41 +/- 1.5% in group C, with a significant difference between groups A and C (p < 0.05). The mean percentage area of PCO in the rabbit eye was 19.4 +/- 16.7% in group A, 17.5 +/- 8.5% in group B, and 5.5 +/- 3.8% in group C, with a significant difference between groups A and C (p < 0.05). CONCLUSION Adhesive force of hydrophobic acrylic IOLs may play an important role in preventing PCO. Among the similarly shaped hydrophobic acrylic IOLs, IOLs of highly adhesive material inhibited LEC migration and PCO more than IOLs of less adhesive material.
Collapse
Affiliation(s)
- Yasuhiro Katayama
- The First Department of Ophthalmology, School of Medicine, Toho University, Tokyo, Japan
| | | | | | | |
Collapse
|
53
|
Hayashi K, Hayashi H. Influence on posterior capsule opacification and visual function of intraocular lens optic material. Am J Ophthalmol 2007; 144:195-202. [PMID: 17553447 DOI: 10.1016/j.ajo.2007.04.044] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2007] [Revised: 04/17/2007] [Accepted: 04/19/2007] [Indexed: 10/23/2022]
Abstract
PURPOSE To examine the influence of optic material on posterior capsule opacification (PCO) by comparing PCO and visual functions between eyes with an acrylic intraocular lens (IOLs) and those with a silicone IOL of the same optic design and with the same haptics. DESIGN Randomized clinical trial. METHODS One hundred patients scheduled for phacoemulsification surgery underwent implantation of an acrylic IOL (AMO Sensar; AR40e) in one eye and implantation of a silicone IOL (ClariFlex) of the same optic design and loops in the fellow eye. Eighty-nine patients (89%) remained for analysis. The PCO value was measured using the Scheimpflug videophotography system at one, three, six, 12, 18, 24, 30, and 36 months postoperatively. The incidence of eyes that required a neodymium:yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy was examined; visual acuity and contrast sensitivity with and without a glare source were also evaluated. RESULTS The mean PCO value did not increase significantly during follow-up in either the acrylic or silicone IOL group. When comparing the groups, no statistically significant difference was found in the PCO or in the incidence of Nd:YAG capsulotomy, although both tended to be slightly better in the silicone group than in the acrylic group. There was also no significant difference between the groups in visual acuity or in photopic and mesopic contrast sensitivity with or without glare. CONCLUSIONS When acrylic and silicone IOLs are of the same optic design and with the same haptics, the optic material does not influence the development of PCO enough to impair visual function.
Collapse
|
54
|
Abstract
BACKGROUND Posterior capsule opacification (PCO) remains the most common long-term complication after cataract surgery. It can be treated by Nd:YAG laser capsulotomy, however, this may lead to other complications and laser treatment is not available in large parts of the developing world. Therefore, many studies try to find factors influencing the development of PCO. OBJECTIVES To summarise the effects of different interventions to inhibit PCO. These include modifications of surgical technique and intraocular lens (IOL) design, implantation of additional devices and pharmacological interventions. SEARCH STRATEGY We searched CENTRAL, MEDLINE, EMBASE, LILACS in January 2007 and reference lists of identified trial reports. SELECTION CRITERIA We included only prospective, randomised and controlled trials with a follow-up time of at least 12 months. Interventions included modifications in surgical technique explicitly to inhibit PCO, modifications in IOL design (material and geometry), implantation of additional devices, and pharmacological therapy, compared to each other, placebo or standard treatment. DATA COLLECTION AND ANALYSIS Data were extracted and entered into Review Manager. Visual acuity data, PCO score and YAG capsulotomy rates were compared and a meta-analysis was performed when possible. MAIN RESULTS Fifty three studies were included in the review. The review was divided into three parts. (1) Influence of IOL optic material on the development of PCO. Compared to other materials, the meta-analysis of the included studies showed a significantly higher PCO score (overall effect: 12.39 (95% confidence interval: 9.82 to 14.95), scale 0 to 100) and YAG rate (odds ratio: 8.37 (3.74 to 20.36)) only in hydrogel IOLs. (2) Influence of IOL optic design on the development of PCO. There was a significantly lower PCO score (-8.65 (-10.72 to -6.59), scale 0 to 100) and YAG rate (0.19 (0.11 to 0.35)) in sharp edged than in round edged IOLs, however, not between 1-piece and 3-piece IOLs. (3) Influence of surgical technique and drugs on the development of PCO. There was no significant difference between different types of intra-/postoperative anti-inflammatory treatment except for treatment with an immunotoxin (MDX-A) leading to a significantly lower PCO rate. AUTHORS' CONCLUSIONS Due to the highly significant difference between round and sharp edge IOL optics, IOLs with sharp (posterior) optic edges should be preferred. There is no clear difference between optic materials, except for hydrogel IOLs, that showed more PCO than the other materials. The choice of postoperative anti-inflammatory treatment does not seem to influence PCO development.
Collapse
Affiliation(s)
- O Findl
- Medical University of Vienna, Department of Ophthalmology, Allgemeines Krankenhaus Wien, Währinger Gürtel 18-20, Vienna, Austria, A-1090.
| | | | | | | |
Collapse
|
55
|
Shah A, Spalton DJ, Gilbert C, Vasavada A, Boyce JF, Minassian D, Jayaram H, Mabey D. Effect of intraocular lens edge profile on posterior capsule opacification after extracapsular cataract surgery in a developing country. J Cataract Refract Surg 2007; 33:1259-66. [PMID: 17586384 DOI: 10.1016/j.jcrs.2007.03.044] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2006] [Accepted: 03/20/2007] [Indexed: 10/23/2022]
Abstract
PURPOSE To determine whether square-edged polymethyl methacrylate (PMMA) intraocular lenses (IOLs) reduce posterior capsule opacification (PCO) in the context of extracapsular cataract surgery in a developing country. SETTING A rural hospital in India. METHODS This was a prospective randomized double-masked fellow-eye controlled study. Over a 4-month period, 118 patients with normal eyes apart from age-related cataract were randomized to receive a square-edged or round-edged PMMA IOL in the first eye. The IOLs were identical apart from the edge profile. The fellow-eye had implantation of the alternative IOL within 1 month. Retroillumination images of the posterior capsule were taken using a dedicated camera system and analyzed to quantify the PCO area using POCO software 1 and 2 years postoperatively and the PCO area and severity using POCOman semiqualitative software at 2 years. Visual acuity was measured using a Gujarati logMAR chart. RESULTS One hundred fifteen patients were available for examination at 1 year and 107 at 2 years. With POCO software, the PCO area was reduced in the square-edged IOL group at 1 year (median 30% versus 20%, P=.001) and at 2 years (median 45% versus 35%, P=.006). With POCOman, the PCO area and severity were reduced in the square-edged group at 2 years (median 41.5% versus 33.2%, P=.019 and 0.59 versus 0.46, P=.037, respectively). There was no significant difference in visual acuity between the 2 groups at 1 or 2 years. CONCLUSIONS Sophisticated image analysis techniques can be used in developing countries to quantify PCO. Using extracapsular surgery, square-edged PMMA IOLs reduced the PCO area and severity compared with an identical round-edged IOL; however, the differences were not as marked as those reported with phacoemulsification. This may be due to the difficulty of performing a capsulorhexis that lies on the IOL surface in this situation. Nevertheless, square-edged IOLs offer a potential benefit for extracapsular surgery in the developing world.
Collapse
Affiliation(s)
- Alpesh Shah
- Iladevi Cataract and IOL Research Centre, Ahmedabad, India
| | | | | | | | | | | | | | | |
Collapse
|
56
|
Vyas AV, Narendran R, Bacon PJ, Apple DJ. Three-hundred-sixty degree barrier effect of a square-edged and an enhanced-edge intraocular lens on centripetal lens epithelial cell migration Two-year results. J Cataract Refract Surg 2007; 33:81-7. [PMID: 17189798 DOI: 10.1016/j.jcrs.2006.08.048] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2006] [Accepted: 08/24/2006] [Indexed: 10/23/2022]
Abstract
PURPOSE To study the 360-degree barrier effect of an intraocular lens (IOL) with a square edge at the optic and an enhanced square edge at the optic-haptic junctions (Rayner 570C C-flex) on centripetal migration of lens epithelial cells (LECs) over a 2-year period. SETTING Department of Ophthalmology, Scarborough Hospital, Scarborough, United Kingdom. METHODS In a prospective study of 40 consecutive eyes, a C-flex IOL was implanted in the bag after phacoemulsification surgery. Eyes with intraoperative complications, requiring additional procedures, without 360-degree overlap of the optic, or with capsule block syndrome were excluded. Follow-up was at 6, 10, 18, and 24 months. At each visit, high-magnification retroillumination digital photographs were taken using a slitlamp-attached digital camera. The barrier effect to LEC migration across the optic edge and the enhanced square edge at the optic-haptic junction was graded as complete (no epithelial pearls or sheet), partial (few epithelial pearls without sheet), and minimal/none (epithelial sheet behind the IOL optic). RESULTS Twenty-four patients came to the final follow-up at 24 months. Fifteen of these eyes (63%) had a complete barrier effect throughout the 360 degrees of the IOL. Three eyes (13%) had a partial barrier effect throughout the 360 degrees of the IOL. Three eyes had a complete optic barrier effect but a partial optic-haptic junction barrier effect. Three eyes had a partial optic barrier effect but a complete optic-haptic junction barrier effect. No eye had epithelial sheets extending behind the optic at any location. CONCLUSIONS This study showed the barrier effect of the edge design of the C-flex IOL and the efficacy of the enhanced edge in preventing LEC migration at the optic-haptic junction. The enhanced edge was as effective as a sharp square edge in restricting the LEC migration.
Collapse
Affiliation(s)
- Ashokkumar V Vyas
- Moran Eye Center, Department of Ophthalmology and Visual Sciences, Salt Lake City, Utah, USA.
| | | | | | | |
Collapse
|
57
|
Hancox J, Spalton D, Heatley C, Jayaram H, Yip J, Boyce J, Marshall J. Fellow-eye comparison of posterior capsule opacification rates after implantation of 1CU accommodating and AcrySof MA30 monofocal intraocular lenses. J Cataract Refract Surg 2007; 33:413-7. [PMID: 17321391 DOI: 10.1016/j.jcrs.2006.10.056] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2006] [Accepted: 10/13/2006] [Indexed: 10/23/2022]
Abstract
PURPOSE To measure posterior capsule opacification (PCO) and neodymium:YAG (Nd:YAG) capsulotomy rates between the AcrySof MA30 intraocular lens (IOL) (Alcon) and the 1CU IOL (HumanOptics) in a fellow-eye comparison. SETTING Ophthalmology Department, St. Thomas' Hospital, London, United Kingdom. METHODS Thirty patients who had bilateral cataract surgery with a 1CU IOL prospectively randomly allocated to 1 eye and an AcrySof MA30 monofocal IOL to the other eye were examined. Best corrected distance visual acuity was recorded using the Early Treatment Diabetic Retinopathy Study logMAR chart. Digital retroillumination images of the posterior capsule were taken with the pupil dilated and analyzed with POCO software. RESULTS Eyes with the 1CU IOL had significantly higher PCO rates than eyes with the MA30 IOL at all time points. By 2 years after surgery, 50% of eyes with a 1CU IOL had required Nd:YAG capsulotomy compared with no eyes with an MA30 IOL. There was no significant difference in visual acuity at any time point when post Nd:YAG capsulotomy was taken in to account. CONCLUSIONS The 1CU IOL has 4 broad optic-haptic junctions where the square-edged barrier is breached; this appeared to allow passage of lens epithelial cells, leading to an increase in PCO. However, the increased PCO cannot be attributed to this alone as the 1CU is hydrophilic, a factor known to be associated with higher PCO rates.
Collapse
Affiliation(s)
- Joanne Hancox
- Ophthalmology Department, St. Thomas' Hospital, London, United Kingdom
| | | | | | | | | | | | | |
Collapse
|
58
|
Cheng JW, Wei RL, Cai JP, Xi GL, Zhu H, Li Y, Ma XY. Efficacy of different intraocular lens materials and optic edge designs in preventing posterior capsular opacification: a meta-analysis. Am J Ophthalmol 2007; 143:428-36. [PMID: 17224119 DOI: 10.1016/j.ajo.2006.11.045] [Citation(s) in RCA: 79] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2006] [Revised: 11/16/2006] [Accepted: 11/19/2006] [Indexed: 11/27/2022]
Abstract
PURPOSE To evaluate the efficacy of different intraocular lens (IOL) materials and optic edge designs in preventing posterior capsular opacification (PCO). DESIGN Systematic review and meta-analysis. METHODS Pertinent studies were selected through an electronic search of the Cochrane Library, MEDLINE, and Embase. The randomized controlled trials meeting the predefined criteria were reviewed systematically by meta-analysis. The treatment effects were measured as risk difference, and the pooled estimates were computed according to a random effect model. RESULTS In total, 23 randomized controlled trials were included in the present meta-analysis. The pooled risk differences of Nd:YAG laser capsulotomy rates were -24% (95% confidence interval [CI], -29% to -20%) comparing acrylic with polymethylmethacrylate (PMMA) lenses; -9% (95% CI, -17% to -1%) comparing silicone with PMMA lenses; 14% (95% CI, -8% to 36%) comparing hydrogel with PMMA lenses; 4% (95% CI, -2% to 10%) comparing silicone with acrylic lenses; 19% (95% CI, 8% to 30%) comparing hydrogel with acrylic lenses; and 28% (95% CI, 10% to 46%) comparing hydrogel with silicone lenses. The pooled risk differences of PCO rates were -39% (95% CI, -47% to -31%) comparing acrylic with PMMA lenses; -14% (95% CI, -29% to 0%) comparing silicone with acrylic lenses; 56% (95% CI, 36% to 75%) comparing hydrogel with acrylic lenses; and 48% (95% CI, 31% to 64%) comparing hydrogel with silicone lenses. When comparing sharp with rounded-edge designs, pooled risk differences of capsulotomy rates were -47% (95% CI, -77% to -17%) in PMMA lenses, -22% (95% CI, -47% to 2%) in acrylic lenses, and -9% (95% CI, -17% to 0%) in silicone lenses; pooled risk differences of PCO rates were -28% (95% CI, -50% to -7%) in acrylic lenses and -37% (95% CI, -46% to -27%) in silicone lenses. CONCLUSIONS The rates of PCO and Nd:YAG laser capsulotomy may be influenced by different IOL biomaterials and optic edge designs. The lenses made by acrylic and silicone and those with sharp optic edges are superior in lowering the rates of PCO and laser capsulotomy.
Collapse
Affiliation(s)
- Jin-Wei Cheng
- Department of Ophthalmology, Changzheng Hospital, Second Military Medical University, Shanghai, China
| | | | | | | | | | | | | |
Collapse
|
59
|
Abstract
PURPOSE OF REVIEW Imaging of the crystalline lens and intraocular lens is becoming increasingly more important to optimize the refractive outcome of cataract surgery, to detect and manage complications and to ascertain advanced intraocular lens performance. This review examines recent advances in anterior segment imaging. RECENT FINDINGS The main techniques used for imaging the anterior segment are slit-lamp biomicroscopy, ultrasound biomicroscopy, scheimpflug imaging, phakometry, optical coherence tomography and magnetic resonance imaging. They have principally been applied to the assessment of intraocular lens centration, tilt, position relative to the iris and movement with ciliary body contraction. SUMMARY Despite the advances in anterior chamber imaging technology, there is still the need for a clinical, high-resolution, true anatomical, noninvasive technique to image behind the peripheral iris.
Collapse
Affiliation(s)
- James S Wolffsohn
- Ophthalmic Research Group, Life and Health Sciences, Aston University, Birmingham, UK.
| | | |
Collapse
|
60
|
Miyata K, Kato S, Nejima R, Miyai T, Honbo M, Ohtani S. Influences of optic edge design on posterior capsule opacification and anterior capsule contraction. ACTA ACUST UNITED AC 2006; 85:99-102. [PMID: 17244219 DOI: 10.1111/j.1600-0420.2006.00758.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
PURPOSE To investigate the influence of optic edge design on posterior capsule opacification (PCO) and anterior capsule contraction (ACC). METHODS A total of 43 eyes of 43 patients scheduled to undergo cataract surgery were included in this study. Patients received either a Sensor AR40 intraocular lens (IOL) or a Sensor AR40e IOL. The area of the anterior capsule opening (ACO) was determined by diaphanoscopy using the anterior eye segment analysis system EAS-1000 at 1 day, 1 week and 1, 3, 6 and 12 months postoperatively. Posterior capsule opacification was evaluated objectively in two ways, using either the EAS-1000 or POCOman. RESULTS There was no significant difference between the two groups in either ACO area or percentage reduction of ACO area at any time-point after surgery. The difference in the degree of PCO 1 year after surgery was not significant when measured by either the EAS-1000 or POCOman. CONCLUSIONS A sharp IOL edge is required to prevent PCO. Sharp-edged IOLs do not appear to be a risk factor for ACC.
Collapse
|
61
|
Hayashi K, Yoshida M, Hayashi H. Comparison of posterior capsule opacification between fellow eyes with two types of acrylic intraocular lens. Eye (Lond) 2006; 22:35-41. [PMID: 16823457 DOI: 10.1038/sj.eye.6702496] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To compare the degree of posterior capsule opacification (PCO) and visual function between fellow eyes that received two different types of hydrophobic acrylic intraocular lenses (IOLs). METHODS Forty-five patients underwent bilateral phacoemulsification and implantation of an Alcon AcrySof IOL (MA60AC) in one eye and an AMO Sensar IOL (AR40e) in the fellow eye. The PCO density value was measured using the Scheimpflug videophotography system at 1, 6, 12, and 24 months after surgery. The incidence of eyes that required a neodymium:YAG (Nd:YAG) laser capsulotomy, visual acuity, and contrast sensitivity with and without a glare source were also examined. RESULTS The mean PCO value did not show a significant increase in either the AcrySof MA60AC or Sensar AR40e IOL groups, and was similar between the two groups throughout the 24-month follow-up period. The incidence of Nd:YAG laser capsulotomy was also the same between the groups. No significant difference was found in mean visual acuity between the two IOL groups during the follow-up, and there was no significant difference in photopic or mesopic contrast visual acuity with and without a glare source at 1 and 24 months after surgery. CONCLUSION The degree of PCO in eyes with an AcrySof IOL are almost the same as that in eyes with a Sensar IOL, with the results that visual acuity and contrast sensitivity with and without glare are similar.
Collapse
Affiliation(s)
- K Hayashi
- Private Hospital of Ophthalmology, Hayashi Eye Hospital, Hakata-Ku, Fukuoka, Japan.
| | | | | |
Collapse
|
62
|
Hayashi K, Yoshida M, Hayashi H. Posterior capsule opacification in myopic eyes. J Cataract Refract Surg 2006; 32:634-8. [PMID: 16698486 DOI: 10.1016/j.jcrs.2006.01.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2005] [Accepted: 03/23/2005] [Indexed: 10/24/2022]
Abstract
PURPOSE To determine whether posterior capsule opacification (PCO) is extensive in eyes with myopia or long axial length when an intraocular lens (IOL) of low-power, zero-power, or minus-power, is implanted. SETTING Hayashi Eye Hospital, Fukuoka, Japan. METHODS Ninety eyes of 90 patients scheduled for phacoemulsification surgery were recruited. These consisted of 30 eyes with high (> or =-8 diopters [D]) myopia, 30 eyes with moderate (<-8 D and > or =-3 D) myopia, and 30 eyes with low (<-3 D) myopia. All eyes had implantation of an acrylic IOL-low-power, zero-power, or minus-power-with a sharp optic edge (AcrySof MA60BM or MA60MA, Alcon Surgical). The PCO in these eyes was measured using a Scheimpflug videophotography system (EAS-1000, Nidek) 1, 3, 6, 12, 18, and 24 months after surgery. Visual acuity and the incidence of neodymium:YAG (Nd:YAG) laser posterior capsulotomy were also examined. RESULTS No significant difference was observed in the mean PCO value or in the Nd:YAG capsulotomy rate between the high myopia, moderate myopia, or low myopia groups throughout the follow-up period. There was also no significant correlation between PCO value and the actual spherical power or axial length of the eye. Furthermore, although mean visual acuity tended to be worse in proportion to the degree of myopia, the difference was not statistically significant. CONCLUSION When an acrylic IOL of low-power, zero-power, or minus-power with a sharp optic edge was implanted, high myopia and long axial length were not associated with the degree of PCO.
Collapse
Affiliation(s)
- Ken Hayashi
- Hayashi Eye Hospital, School of Medicine, Fukuoka University, Fukuoka, Japan.
| | | | | |
Collapse
|
63
|
Abstract
PURPOSE OF REVIEW This paper assesses the factors that contribute to the formation of an effective capsular bend as a deterrent to posterior capsule opacification. Its goal is to assist the practicing ophthalmologist in separating current understanding of this process from various working models previously proposed. RECENT FINDINGS While a square-edge design appreciably improves resistance to posterior capsule opacification, significant factors remain under the control of the surgeon. These factors combine to form the physical and psychological barrier of a capsular bend. Innovative digital imaging has shown lens epithelial cell migration, allowing for a more rapid assessment of posterior capsule opacification resistance. A three-piece intraocular lens allows for full 360 degree capsular bend formation surrounding the optic edge; some single-piece designs may inhibit capsular bend formation. Decreasing, but not eliminating, the surviving lens epithelial cell population may diminish capsular bend strength, which may decrease resistance to posterior capsule opacification in the face of a regenerating cortex. All demographic features of clear/refractive lens exchange suggest higher rates of posterior capsule opacification than with standard cataract surgery. SUMMARY The quality of capsular bend formation will determine how resistant an intraocular lens will be to posterior capsule opacification as a consequence of regenerating cortex. As refractive lens exchange and new accommodating intraocular lens designs become more popular, the problems of regenerating cortex will increase in magnitude.
Collapse
Affiliation(s)
- Steven Dewey
- Colorado Springs Health Partners, PC, 209 South Nevada Avenue, CO 80903, USA.
| |
Collapse
|
64
|
|