51
|
Lee D, Choi YH, Lee W. Enhancement of inflection point focusing and rare-cell separations from untreated whole blood. LAB ON A CHIP 2020; 20:2861-2871. [PMID: 32647850 DOI: 10.1039/d0lc00309c] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Inertial microfluidic systems have been widely used for particle or cell separation applications, especially for rare-cell enrichment and separation from blood due to the high throughput and simplicity of the systems. However, most of the separation techniques using inertial microfluidic systems require dilution of blood samples or RBC lysis to achieve a high separation efficiency, which can adversely affect the throughput and/or analysis of the collected sample. We developed a cell separation technique compatible with untreated whole blood by inflection point focusing, that is, an inertial focusing phenomenon toward inflection points of the velocity profile. We generated a strong shear-gradient lift force by varying the velocity profile in a channel cross-section with the combined effect of the channel geometry and the co-flows of two liquids with different viscosities. The natural viscosity of blood leads to a lagging flow region in the middle of the channel where larger particles and cells can be extracted to the side flow region, which enables a highly efficient separation scheme with an unprecedented high throughput.
Collapse
Affiliation(s)
- Dongwoo Lee
- Graduate School of Nanoscience and Technology, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea.
| | | | | |
Collapse
|
52
|
Dalili A, Taatizadeh E, Tahmooressi H, Tasnim N, Rellstab-Sánchez PI, Shaunessy M, Najjaran H, Hoorfar M. Parametric study on the geometrical parameters of a lab-on-a-chip platform with tilted planar electrodes for continuous dielectrophoretic manipulation of microparticles. Sci Rep 2020; 10:11718. [PMID: 32678180 PMCID: PMC7366698 DOI: 10.1038/s41598-020-68699-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Accepted: 06/22/2020] [Indexed: 02/08/2023] Open
Abstract
Advances in lab-on-a-chip (LOC) devices have led to significant improvements in the on-chip manipulation, separation, sorting, and isolation of particles and cells. Among various LOC-based approaches such as inertia-based methods, acoustophoresis, and magnetophoresis, the planar-slanted-electrode dielectrophoresis (DEP) method has demonstrated great potential as a label-free, cost-effective, and user-friendly approach. However, the devices built based on this method suffer from low flow throughput compared to devices functioning based on other LOC-based manipulation approaches. In order to overcome this obstacle, the geometrical parameters of these types of DEP-based devices must be studied to increase the effectiveness of DEP manipulation. With the consideration of both numerical and experimental studies, this paper studies the geometrical factors of a LOC platform consisting of tilted planar electrodes with the goal of achieving higher throughput in continuous manipulation of polystyrene particles. COMSOL Multiphysics software was used to study the effect of the electrodes geometry on the induced electric field. The simulation results show that by increasing the electrode's width and decreasing the electrode's spacing, higher DEP force is generated. Furthermore, the experimental outcomes indicated that lower channel height, higher voltage, and larger particle size resulted in the most improvement to DEP manipulation. Additionally, the experimental results demonstrated that slanted electrodes with an angle of 8° with respect to the direction of flow provide a more effective configuration.
Collapse
Affiliation(s)
- Arash Dalili
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Erfan Taatizadeh
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
- School of Biomedical Engineering, Faculty of Applied Science, Faculty of Medicine, The University of British Columbia, Vancouver, BC, V6T 1Z3, Canada
| | - Hamed Tahmooressi
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Nishat Tasnim
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Pamela Inés Rellstab-Sánchez
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Matthew Shaunessy
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Homayoun Najjaran
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Mina Hoorfar
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada.
| |
Collapse
|
53
|
Nasiri R, Shamloo A, Ahadian S, Amirifar L, Akbari J, Goudie MJ, Lee K, Ashammakhi N, Dokmeci MR, Di Carlo D, Khademhosseini A. Microfluidic-Based Approaches in Targeted Cell/Particle Separation Based on Physical Properties: Fundamentals and Applications. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e2000171. [PMID: 32529791 DOI: 10.1002/smll.202000171] [Citation(s) in RCA: 115] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 03/15/2020] [Indexed: 06/11/2023]
Abstract
Cell separation is a key step in many biomedical research areas including biotechnology, cancer research, regenerative medicine, and drug discovery. While conventional cell sorting approaches have led to high-efficiency sorting by exploiting the cell's specific properties, microfluidics has shown great promise in cell separation by exploiting different physical principles and using different properties of the cells. In particular, label-free cell separation techniques are highly recommended to minimize cell damage and avoid costly and labor-intensive steps of labeling molecular signatures of cells. In general, microfluidic-based cell sorting approaches can separate cells using "intrinsic" (e.g., fluid dynamic forces) versus "extrinsic" external forces (e.g., magnetic, electric field, etc.) and by using different properties of cells including size, density, deformability, shape, as well as electrical, magnetic, and compressibility/acoustic properties to select target cells from a heterogeneous cell population. In this work, principles and applications of the most commonly used label-free microfluidic-based cell separation methods are described. In particular, applications of microfluidic methods for the separation of circulating tumor cells, blood cells, immune cells, stem cells, and other biological cells are summarized. Computational approaches complementing such microfluidic methods are also explained. Finally, challenges and perspectives to further develop microfluidic-based cell separation methods are discussed.
Collapse
Affiliation(s)
- Rohollah Nasiri
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, 11365-11155, Iran
| | - Amir Shamloo
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, 11365-11155, Iran
| | - Samad Ahadian
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, CA, 90024, USA
| | - Leyla Amirifar
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, 11365-11155, Iran
| | - Javad Akbari
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, 11365-11155, Iran
| | - Marcus J Goudie
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - KangJu Lee
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Nureddin Ashammakhi
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Radiological Sciences, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Mehmet R Dokmeci
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, CA, 90024, USA
- Department of Radiological Sciences, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Dino Di Carlo
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Ali Khademhosseini
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, CA, 90024, USA
- Department of Radiological Sciences, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Chemical and Biomolecular Engineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| |
Collapse
|
54
|
Ooi C, Earhart CM, Hughes CE, Lee JR, Wong DJ, Wilson RJ, Rohatgi R, Wang SX. Flow Homogenization Enables a Massively Parallel Fluidic Design for High-throughput and Multiplexed Cell Isolation. ADVANCED MATERIALS TECHNOLOGIES 2020; 5:1900960. [PMID: 33072854 PMCID: PMC7567302 DOI: 10.1002/admt.201900960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Accepted: 03/04/2020] [Indexed: 06/11/2023]
Abstract
Microfluidic devices are widely used for applications such as cell isolation. Currently, the most common method to improve throughput for microfluidic devices involves fabrication of multiple, identical channels in parallel. However, this 'numbering up' only occurs in one dimension, thereby limiting gains in volumetric throughput. In contrast, macro-fluidic devices permit high volumetric flow-rates but lack the finer control of microfluidics. Here, we demonstrate how a micro-pore array design enables flow homogenization across a magnetic cell capture device, thus creating a massively parallel series of micro-scale flow channels with consistent fluidic and magnetic properties, regardless of spatial location. This design enables scaling in 2-dimensions, allowing flow-rates exceeding 100 mL/hr while maintaining >90% capture efficiencies of spiked lung cancer cells from blood in a simulated circulating tumor cell system. Additionally, this design facilitates modularity in operation, which we demonstrate by combining two different devices in tandem for multiplexed cell separation in a single pass with no additional cell losses from processing.
Collapse
Affiliation(s)
- Chinchun Ooi
- Department of Chemical Engineering, Stanford University, Stanford, California, USA; Department of Fluid Dynamics, Institute of High Performance Computing, Singapore
| | - Christopher M. Earhart
- Department of Materials Science and Engineering, Stanford University, Stanford, California, USA
| | - Casey E. Hughes
- Division of Oncology, Department of Medicine, Stanford University School of Medicine, Stanford, California, USA; Department of Biochemistry, University of Utah School of Medicine, Salt Lake City, Utah, USA
| | - Jung-Rok Lee
- Division of Mechanical and Biomechanical Engineering, Ewha Womans University, Seoul, South Korea
| | - Dawson J. Wong
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Robert J. Wilson
- Department of Materials Science and Engineering, Stanford University, Stanford, California, USA
| | - Rajat Rohatgi
- Department of Biochemistry, Stanford University School of Medicine, Stanford, California, USA
| | - Shan X. Wang
- Department of Materials Science and Engineering, Stanford University, Stanford, California, USA; Department of Electrical Engineering, Stanford University, Stanford, California, USA
| |
Collapse
|
55
|
Mihandoust A, Razavi Bazaz S, Maleki-Jirsaraei N, Alizadeh M, A. Taylor R, Ebrahimi Warkiani M. High-Throughput Particle Concentration Using Complex Cross-Section Microchannels. MICROMACHINES 2020; 11:E440. [PMID: 32331275 PMCID: PMC7231362 DOI: 10.3390/mi11040440] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 04/17/2020] [Accepted: 04/20/2020] [Indexed: 12/19/2022]
Abstract
High throughput particle/cell concentration is crucial for a wide variety of biomedical, clinical, and environmental applications. In this work, we have proposed a passive spiral microfluidic concentrator with a complex cross-sectional shape, i.e., a combination of rectangle and trapezoid, for high separation efficiency and a confinement ratio less than 0.07. Particle focusing in our microfluidic system was observed in a single, tight focusing line, in which higher particle concentration is possible, as compared with simple rectangular or trapezoidal cross-sections with similar flow area. The sharper focusing stems from the confinement of Dean vortices in the trapezoidal region of the complex cross-section. To quantify this effect, we introduce a new parameter, complex focusing number or CFN, which is indicative of the enhancement of inertial focusing of particles in these channels. Three spiral microchannels with various widths of 400 µm, 500 µm, and 600 µm, with the corresponding CFNs of 4.3, 4.5, and 6, respectively, were used. The device with the total width of 600 µm was shown to have a separation efficiency of ~98%, and by recirculating, the output concentration of the sample was 500 times higher than the initial input. Finally, the investigation of results showed that the magnitude of CFN relies entirely on the microchannel geometry, and it is independent of the overall width of the channel cross-section. We envision that this concept of particle focusing through complex cross-sections will prove useful in paving the way towards more efficient inertial microfluidic devices.
Collapse
Affiliation(s)
- Asma Mihandoust
- Complex Systems Laboratory, School of Physics-Chemistry, Department of Physics, Alzahra University, Tehran 1993893973, Iran; (A.M.); (N.M.-J.)
| | - Sajad Razavi Bazaz
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW 2007, Australia;
| | - Nahid Maleki-Jirsaraei
- Complex Systems Laboratory, School of Physics-Chemistry, Department of Physics, Alzahra University, Tehran 1993893973, Iran; (A.M.); (N.M.-J.)
| | - Majid Alizadeh
- School of Paramedicine, Ilam University of Medical Science, Ilam 6939177143, Iran;
| | - Robert A. Taylor
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW 2052, Australia;
| | - Majid Ebrahimi Warkiani
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW 2007, Australia;
- Institute of Molecular Medicine, Sechenov University, 119991 Moscow, Russia
| |
Collapse
|
56
|
Razavi Bazaz S, Rouhi O, Raoufi MA, Ejeian F, Asadnia M, Jin D, Ebrahimi Warkiani M. 3D Printing of Inertial Microfluidic Devices. Sci Rep 2020; 10:5929. [PMID: 32246111 PMCID: PMC7125121 DOI: 10.1038/s41598-020-62569-9] [Citation(s) in RCA: 73] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Accepted: 03/11/2020] [Indexed: 12/27/2022] Open
Abstract
Inertial microfluidics has been broadly investigated, resulting in the development of various applications, mainly for particle or cell separation. Lateral migrations of these particles within a microchannel strictly depend on the channel design and its cross-section. Nonetheless, the fabrication of these microchannels is a continuous challenging issue for the microfluidic community, where the most studied channel cross-sections are limited to only rectangular and more recently trapezoidal microchannels. As a result, a huge amount of potential remains intact for other geometries with cross-sections difficult to fabricate with standard microfabrication techniques. In this study, by leveraging on benefits of additive manufacturing, we have proposed a new method for the fabrication of inertial microfluidic devices. In our proposed workflow, parts are first printed via a high-resolution DLP/SLA 3D printer and then bonded to a transparent PMMA sheet using a double-coated pressure-sensitive adhesive tape. Using this method, we have fabricated and tested a plethora of existing inertial microfluidic devices, whether in a single or multiplexed manner, such as straight, spiral, serpentine, curvilinear, and contraction-expansion arrays. Our characterizations using both particles and cells revealed that the produced chips could withstand a pressure up to 150 psi with minimum interference of the tape to the total functionality of the device and viability of cells. As a showcase of the versatility of our method, we have proposed a new spiral microchannel with right-angled triangular cross-section which is technically impossible to fabricate using the standard lithography. We are of the opinion that the method proposed in this study will open the door for more complex geometries with the bespoke passive internal flow. Furthermore, the proposed fabrication workflow can be adopted at the production level, enabling large-scale manufacturing of inertial microfluidic devices.
Collapse
Affiliation(s)
- Sajad Razavi Bazaz
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, 2007, Australia
- Institute for Biomedical Materials & Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia
| | - Omid Rouhi
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, 2007, Australia
| | - Mohammad Amin Raoufi
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, 2007, Australia
- School of Engineering, Macquarie University, Sydney, NSW, 2109, Australia
| | - Fatemeh Ejeian
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, 2007, Australia
| | - Mohsen Asadnia
- School of Engineering, Macquarie University, Sydney, NSW, 2109, Australia
| | - Dayong Jin
- Institute for Biomedical Materials & Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia
- SUStech-UTS joint Research Centre for Biomedical Materials & Devices, Southern University of Science and Technology, Shenzhen, 518055, P.R. China
| | - Majid Ebrahimi Warkiani
- School of Biomedical Engineering, University of Technology Sydney, Sydney, NSW, 2007, Australia.
- Institute for Biomedical Materials & Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, NSW, 2007, Australia.
- SUStech-UTS joint Research Centre for Biomedical Materials & Devices, Southern University of Science and Technology, Shenzhen, 518055, P.R. China.
- Institute of Molecular Medicine, Sechenov University, Moscow, 119991, Russia.
| |
Collapse
|
57
|
Sonmez UM, Coyle S, Taylor RE, LeDuc PR. Polycarbonate Heat Molding for Soft Lithography. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e2000241. [PMID: 32227442 DOI: 10.1002/smll.202000241] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 02/28/2020] [Accepted: 03/02/2020] [Indexed: 06/10/2023]
Abstract
Soft lithography enables rapid microfabrication of many types of microsystems by replica molding elastomers into master molds. However, master molds can be very costly, hard to fabricate, vulnerable to damage, and have limited casting life. Here, an approach for the multiplication of master molds into monolithic thermoplastic sheets for further soft lithographic fabrication is introduced. The technique is tested with master molds fabricated through photolithography, mechanical micromilling as well as 3D printing, and the results are demonstrated. Microstructures with submicron feature sizes and high aspect ratios are successfully copied. The copying fidelity of the technique is quantitatively characterized and the microfluidic devices fabricated through this technique are functionally tested. This approach is also used to combine different master molds with up to 19 unique geometries into a single monolithic copy mold in a single step displaying the effectiveness of the copying technique over a large footprint area to scale up the microfabrication. This microfabrication technique can be performed outside the cleanroom without using any sophisticated equipment, suggesting a simple way for high-throughput rigid monolithic mold fabrication that can be used in analytical chemistry studies, biomedical research, and microelectromechanical systems.
Collapse
Affiliation(s)
- Utku M Sonmez
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, 15213, USA
| | - Stephen Coyle
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, 15213, USA
| | - Rebecca E Taylor
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, 15213, USA
| | - Philip R LeDuc
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, 15213, USA
| |
Collapse
|
58
|
Guzniczak E, Otto O, Whyte G, Chandra T, Robertson NA, Willoughby N, Jimenez M, Bridle H. Purifying stem cell-derived red blood cells: a high-throughput label-free downstream processing strategy based on microfluidic spiral inertial separation and membrane filtration. Biotechnol Bioeng 2020; 117:2032-2045. [PMID: 32100873 PMCID: PMC7383897 DOI: 10.1002/bit.27319] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 02/17/2020] [Accepted: 02/24/2020] [Indexed: 02/06/2023]
Abstract
Cell-based therapeutics, such as in vitro manufactured red blood cells (mRBCs), are different to traditional biopharmaceutical products (the final product being the cells themselves as opposed to biological molecules such as proteins) and that presents a challenge of developing new robust and economically feasible manufacturing processes, especially for sample purification. Current purification technologies have limited throughput, rely on expensive fluorescent or magnetic immunolabeling with a significant (up to 70%) cell loss and quality impairment. To address this challenge, previously characterized mechanical properties of umbilical cord blood CD34+ cells undergoing in vitro erythropoiesis were used to develop an mRBC purification strategy. The approach consists of two main stages: (a) a microfluidic separation using inertial focusing for deformability-based sorting of enucleated cells (mRBC) from nuclei and nucleated cells resulting in 70% purity and (b) membrane filtration to enhance the purity to 99%. Herein, we propose a new route for high-throughput (processing millions of cells/min and mls of medium/min) purification process for mRBC, leading to high mRBC purity while maintaining cell integrity and no alterations in their global gene expression profile. Further adaption of this separation approach offers a potential route for processing of a wide range of cellular products.
Collapse
Affiliation(s)
- Ewa Guzniczak
- Department of Biological Chemistry, Biophysics and Bioengineering Edinburgh Campus, School of Engineering and Physical Science, Heriot-Watt University, Edinburgh, Scotland
| | - Oliver Otto
- Centre for Innovation Competence - Humoral Immune Reactions in Cardiovascular Diseases, University of Greifswald, Greifswald, Germany.,Deutsches Zentrum für Herz-Kreislaufforschung, Partner Site Greifswald, Greifswald, Germany
| | - Graeme Whyte
- Department of Biological Chemistry, Biophysics and Bioengineering Edinburgh Campus, School of Engineering and Physical Science, Heriot-Watt University, Edinburgh, Scotland
| | - Tamir Chandra
- MRC Human Genetics Unit, MRC Institute of Genetics & Molecular Medicine, The University of Edinburgh, Western General Hospital, Edinburgh, Scotland
| | - Neil A Robertson
- MRC Human Genetics Unit, MRC Institute of Genetics & Molecular Medicine, The University of Edinburgh, Western General Hospital, Edinburgh, Scotland
| | - Nik Willoughby
- Department of Biological Chemistry, Biophysics and Bioengineering Edinburgh Campus, School of Engineering and Physical Science, Heriot-Watt University, Edinburgh, Scotland
| | - Melanie Jimenez
- Biomedical Engineering Division, James Watt School of Engineering, University of Glasgow, Glasgow, Scotland
| | - Helen Bridle
- Department of Biological Chemistry, Biophysics and Bioengineering Edinburgh Campus, School of Engineering and Physical Science, Heriot-Watt University, Edinburgh, Scotland
| |
Collapse
|
59
|
Microfluidic Passive Valve with Ultra-Low Threshold Pressure for High-Throughput Liquid Delivery. MICROMACHINES 2019; 10:mi10120798. [PMID: 31766417 PMCID: PMC6952951 DOI: 10.3390/mi10120798] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Revised: 11/16/2019] [Accepted: 11/20/2019] [Indexed: 12/13/2022]
Abstract
The microvalve for accurate flow control under low fluidic pressure is vital in cost-effective and miniaturized microfluidic devices. This paper proposes a novel microfluidic passive valve comprising of a liquid chamber, an elastic membrane, and an ellipsoidal control chamber, which actualizes a high flow rate control under an ultra-low threshold pressure. A prototype of the microvalve was fabricated by 3D printing and UV laser-cutting technologies and was tested under static and time-dependent pressure conditions. The prototype microvalve showed a nearly constant flow rate of 4.03 mL/min, with a variation of ~4.22% under the inlet liquid pressures varied from 6 kPa to 12 kPa. In addition, the microvalve could stabilize the flow rate of liquid under the time-varying sinusoidal pressures or the square wave pressures. To validate the functionality of the microvalve, the prototype microvalve was applied in a gas-driven flow system which employed an air blower or human mouth blowing as the low-cost gas source. The microvalve was demonstrated to successfully regulate the steady flow delivery in the system under the low driving pressures produced by the above gas sources. We believe that this new microfluidic passive valve will be suitable for controlling fluid flow in portable microfluidic devices or systems of wider applications.
Collapse
|
60
|
Suwannaphan T, Srituravanich W, Sailasuta A, Piyaviriyakul P, Bhanpattanakul S, Jeamsaksiri W, Sripumkhai W, Pimpin A. Investigation of Leukocyte Viability and Damage in Spiral Microchannel and Contraction-Expansion Array. MICROMACHINES 2019; 10:E772. [PMID: 31726665 PMCID: PMC6915465 DOI: 10.3390/mi10110772] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2019] [Revised: 11/05/2019] [Accepted: 11/07/2019] [Indexed: 12/22/2022]
Abstract
Inertial separation techniques in a microfluidic system have been widely employed in the field of medical diagnosis for a long time. Despite no requirement of external forces, it requires strong hydrodynamic forces that could potentially cause cell damage or loss during the separation process. This might lead to the wrong interpretation of laboratory results since the change of structures and functional characteristics of cells due to the hydrodynamic forces that occur are not taken into account. Therefore, it is important to investigate the cell viability and damage along with the separation efficacy of the device in the design process. In this study, two inertial separation techniques-spiral microchannel and contraction-expansion array (CEA)-were examined to evaluate cell viability, morphology and intracellular structures using a trypan blue assay (TB), Scanning Electron Microscopy (SEM) and Wright-Giemsa stain. We discovered that cell loss was not significantly found in a feeding system, i.e., syringe, needle and tube, but mostly occurred in the inertial separation devices while the change of cell morphology and intracellular structures were found in the feeding system and inertial separation devices. Furthermore, percentage of cell loss was not significant in both devices (7-10%). However, the change of cell morphology was considerably increased (30%) in spiral microchannel (shear stress dominated) rather than in CEA (12%). In contrast, the disruption of intracellular structures was increased (14%) in CEA (extensional and shear stress dominated equally) rather than spiral microchannel (2%). In these experiments, leukocytes of canine were used as samples because their sizes are varied in a range between 7-12 µm, and they are commonly used as a biomarker in many clinical and medical applications.
Collapse
Affiliation(s)
- Thammawit Suwannaphan
- Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand; (T.S.); (W.S.)
| | - Werayut Srituravanich
- Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand; (T.S.); (W.S.)
| | - Achariya Sailasuta
- Department of Pathology, Faculty of Veterinary Science, Chulalongkorn University, Bangkok 10330, Thailand;
| | - Prapruddee Piyaviriyakul
- Department of Physiology, Faculty of Veterinary Science, Chulalongkorn University, Bangkok 10330, Thailand; (P.P.); (S.B.)
| | - Suchaya Bhanpattanakul
- Department of Physiology, Faculty of Veterinary Science, Chulalongkorn University, Bangkok 10330, Thailand; (P.P.); (S.B.)
| | - Wutthinan Jeamsaksiri
- Thailand Microelectronic Centre, Ministry of Science and Technology, Chachoengsao 24000, Thailand; (W.J.); (W.S.)
| | - Witsaroot Sripumkhai
- Thailand Microelectronic Centre, Ministry of Science and Technology, Chachoengsao 24000, Thailand; (W.J.); (W.S.)
| | - Alongkorn Pimpin
- Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand; (T.S.); (W.S.)
| |
Collapse
|
61
|
Xiang N, Li Q, Shi Z, Zhou C, Jiang F, Han Y, Ni Z. Low-cost multi-core inertial microfluidic centrifuge for high-throughput cell concentration. Electrophoresis 2019; 41:875-882. [PMID: 31705675 DOI: 10.1002/elps.201900385] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 10/25/2019] [Accepted: 11/05/2019] [Indexed: 12/12/2022]
Abstract
We developed a low-cost multi-core inertial microfluidic centrifuge (IM-centrifuge) to achieve a continuous-flow cell/particle concentration at a throughput of up to 20 mL/min. To lower the cost of our IM-centrifuge, we clamped a disposable multilayer film-based inertial microfluidic (MFIM) chip with two reusable plastic housings. The key MFIM chip was fabricated in low-cost materials by stacking different polymer-film channel layers and double-sided tape. To increase processing throughput, multiplexing spiral inertial microfluidic channels were integrated within an all-in-one MFIM chip, and a novel sample distribution strategy was employed to equally distribute the sample into each channel layer. Then, we characterized the focusing performance in the MFIM chip over a wide flow-rate range. The experimental results showed that our IM-centrifuge was able to focus various-sized particles/cells to achieve volume reduction. The sample distribution strategy also effectively ensured identical focusing and concentration performances in different cores. Finally, our IM-centrifuge was successfully applied to concentrate microalgae cells with irregular shapes and highly polydisperse sizes. Thus, our IM-centrifuge holds the potential to be employed as a low-cost, high-throughput centrifuge for disposable use in low-resource settings.
Collapse
Affiliation(s)
- Nan Xiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Qiao Li
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Zhiguo Shi
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Chenguang Zhou
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Fengtao Jiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Yu Han
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| | - Zhonghua Ni
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, P. R. China
| |
Collapse
|
62
|
Herrmann N, Neubauer P, Birkholz M. Spiral microfluidic devices for cell separation and sorting in bioprocesses. BIOMICROFLUIDICS 2019; 13:061501. [PMID: 31700559 PMCID: PMC6831504 DOI: 10.1063/1.5125264] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Accepted: 10/14/2019] [Indexed: 05/04/2023]
Abstract
Inertial microfluidic systems have been arousing interest in medical applications due to their simple and cost-efficient use. However, comparably small sample volumes in the microliter and milliliter ranges have so far prevented efficient applications in continuous bioprocesses. Nevertheless, recent studies suggest that these systems are well suited for cell separation in bioprocesses because of their facile adaptability to various reactor sizes and cell types. This review will discuss potential applications of inertial microfluidic cell separation systems in downstream bioprocesses and depict recent advances in inertial microfluidics for bioprocess intensification. This review thereby focusses on spiral microchannels that separate particles at a moderate Reynolds number in a laminar flow (Re < 2300) according to their size by applying lateral hydrodynamic forces. Spiral microchannels have already been shown to be capable of replacing microfilters, extracting dead cells and debris in perfusion processes, and removing contaminant microalgae species. Recent advances in parallelization made it possible to process media on a liter-scale, which might pave the way toward industrial applications.
Collapse
Affiliation(s)
- N. Herrmann
- Institute of Biotechnology, Technische Universität Berlin, Ackerstr. 76, 13355 Berlin, Germany
| | - P. Neubauer
- Institute of Biotechnology, Technische Universität Berlin, Ackerstr. 76, 13355 Berlin, Germany
| | - M. Birkholz
- IHP—Leibniz-Institut für innovative Mikroelektronik, Im Technologiepark 25, 15236 Frankfurt (Oder), Germany
| |
Collapse
|
63
|
McBride SA, Dash S, Khan S, Varanasi KK. Evaporative Crystallization of Spirals. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:10484-10490. [PMID: 31260320 DOI: 10.1021/acs.langmuir.9b01002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Spiral motifs are pervasive in nature, art, and technology due to their functional property of providing compact length. Nature is particularly adept at spiral patterning, and yet, the spirals observed in seashells, hurricanes, rams' horns, flower petals, etc. all evolve via disparate physical mechanisms. Here, we present a mechanism for the self-guided formation of spirals from evaporating saline drops via a coupling of crystallization and contact line dynamics. These patterns are in contrast to commonly observed patterns from evaporation of colloidal drops, which are discrete (rings, concentric rings) or continuous (clumps, uniform deposits) depending on the particle shape, contact line dynamics, and evaporation rate. Unlike the typical process of drop evaporation where the contact line moves radially inward, here, a thin film pinned by a ring of crystals ruptures radially outward. This motion is accompanied by a nonuniform pinning of the contact line due to crystallization, which generates a continuous propagation of pinning and depinning events to form a spiral. By comparing the relevant timescales of evaporation and diffusion, we show that a single dimensionless number can predict the occurrence of these patterns. These insights on self-guided crystallization of spirals could be used to create compact length templates.
Collapse
Affiliation(s)
- Samantha A McBride
- Department of Mechanical Engineering , Massachusetts Institute of Technology , 77 Massachusetts Avenue , Cambridge , Massachusetts 02139 , United States
| | - Susmita Dash
- Department of Mechanical Engineering , Indian Institute of Science , CV Raman Road , Bengaluru 560012 , India
| | - Sami Khan
- Department of Mechanical Engineering , Massachusetts Institute of Technology , 77 Massachusetts Avenue , Cambridge , Massachusetts 02139 , United States
| | - Kripa K Varanasi
- Department of Mechanical Engineering , Massachusetts Institute of Technology , 77 Massachusetts Avenue , Cambridge , Massachusetts 02139 , United States
| |
Collapse
|
64
|
Al-Halhouli A, Albagdady A, Al-Faqheri W, Kottmeier J, Meinen S, Frey LJ, Krull R, Dietzel A. Enhanced inertial focusing of microparticles and cells by integrating trapezoidal microchambers in spiral microfluidic channels. RSC Adv 2019; 9:19197-19204. [PMID: 35516901 PMCID: PMC9064905 DOI: 10.1039/c9ra03587g] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Accepted: 06/12/2019] [Indexed: 11/21/2022] Open
Abstract
In this work, manipulating width and equilibrium position of fluorescent microparticles in spiral microchannel fractionation devices by embedding microchambers along the last turn of a spiral is reported. Microchambers with different shapes and sizes were tested at Reynolds numbers between 15.7 and 156.6 (100-1000 μL min-1) to observe focusing of 2, 5 and 10 μm fluorescent microparticles. This paper also discusses the fabrication process of the microfluidic chips with femtosecond laser ablation on glass wafers, as well as a particle imaging velocimetry (μPIV) study of microparticle trajectories inside a microchamber. It could be demonstrated with an improved final design with inclined microchamber side walls, that the 2 μm particle equilibrium position is shifted towards the inner wall by ∼27 μm and the focusing line's width is reduced by ∼18 μm. Finally, Saccharomyces cerevisiae yeast cells were tested in the final chip and a cell focusing efficiency of 99.1% is achieved.
Collapse
Affiliation(s)
| | - Ahmed Albagdady
- NanoLab, School of Applied Technical Sciences, German Jordanian University Amman Jordan
| | - Wisam Al-Faqheri
- MicroNano Mechatronic Lab, Mechanical, Automotive & Materials Engineering, University of Windsor Windsor ON Canada
| | - Jonathan Kottmeier
- Institut für Mikrotechnik, Technische Universität Braunschweig Braunschweig Germany
| | - Sven Meinen
- Institut für Mikrotechnik, Technische Universität Braunschweig Braunschweig Germany
| | - Lasse Jannis Frey
- Zentrum für Pharmaverfahrenstechnik, Technische Universität Braunschweig Braunschweig Germany
| | - Rainer Krull
- Zentrum für Pharmaverfahrenstechnik, Technische Universität Braunschweig Braunschweig Germany
| | - Andreas Dietzel
- Institut für Mikrotechnik, Technische Universität Braunschweig Braunschweig Germany
| |
Collapse
|
65
|
Rafeie M, Hosseinzadeh S, Taylor RA, Warkiani ME. New insights into the physics of inertial microfluidics in curved microchannels. I. Relaxing the fixed inflection point assumption. BIOMICROFLUIDICS 2019; 13:034117. [PMID: 31431813 PMCID: PMC6697030 DOI: 10.1063/1.5109004] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2019] [Accepted: 06/12/2019] [Indexed: 05/08/2023]
Abstract
Inertial microfluidics represents a powerful new tool for accurately positioning cells and microparticles within fluids for a variety of biomedical, clinical, and industrial applications. In spite of enormous advancements in the science and design of these devices, particularly in curved microfluidic channels, contradictory experimental results have confounded researchers and limited progress. Thus, at present, a complete theory which describes the underlying physics is lacking. We propose that this bottleneck is due to one simple mistaken assumption-the locations of inflection points of the Dean velocity profile in curved microchannels are not fixed, but can actually shift with the flow rate. Herein, we propose that the dynamic distance (δ) between the real equilibrium positions and their nearest inflection points can clearly explain several (previously) unexplained phenomena in inertial microfluidic systems. More interestingly, we found that this parameter, δ, is a function of several geometric and operational parameters, all of which are investigated (in detail) here with a series of experiments and simulations of different spiral microchannels. This key piece of understanding is expected to open the door for researchers to develop new and more effective inertial microfluidic designs.
Collapse
Affiliation(s)
- Mehdi Rafeie
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Shahin Hosseinzadeh
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales 2052, Australia
| | | | | |
Collapse
|
66
|
Rafeie M, Hosseinzadeh S, Huang J, Mihandoust A, Warkiani ME, Taylor RA. New insights into the physics of inertial microfluidics in curved microchannels. II. Adding an additive rule to understand complex cross-sections. BIOMICROFLUIDICS 2019; 13:034118. [PMID: 31431814 PMCID: PMC6697028 DOI: 10.1063/1.5109012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2019] [Accepted: 06/12/2019] [Indexed: 05/09/2023]
Abstract
Curved microchannels allow controllable microparticle focusing, but a full understanding of particle behavior has been limited-even for simple rectangular and trapezoidal shapes. At present, most microfluidic particle separation literature is dedicated to adding "internal" complexity (via sheath flow or obstructions) to relatively simple cross-sectional channel shapes. We propose that, with sufficient understanding of particle behavior, an equally viable pathway for microparticle focusing could utilize complex "external" cross-sectional shapes. By investigating three novel, complex spiral microchannels, we have found that it is possible to passively focus (6, 10, and 13 μm) microparticles in the middle of a convex channel. Also, we found that in concave and jagged channel designs, it is possible to create multiple, tight focusing bands. In addition to these performance benefits, we report an "additive rule" herein, which states that complex channels can be considered as multiple, independent, simple cross-sectional shapes. We show with experimental and numerical analysis that this new additive rule can accurately predict particle behavior in complex cross-sectional shaped channels and that it can help to extract general inertial focusing tendencies for suspended particles in curved channels. Overall, this work provides simple, yet reliable, guidelines for the design of advanced curved microchannel cross sections.
Collapse
Affiliation(s)
- Mehdi Rafeie
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Shahin Hosseinzadeh
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Jingrui Huang
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales 2052, Australia
| | | | | | | |
Collapse
|
67
|
Raoufi MA, Mashhadian A, Niazmand H, Asadnia M, Razmjou A, Warkiani ME. Experimental and numerical study of elasto-inertial focusing in straight channels. BIOMICROFLUIDICS 2019; 13:034103. [PMID: 31123535 PMCID: PMC6509046 DOI: 10.1063/1.5093345] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Accepted: 04/22/2019] [Indexed: 05/06/2023]
Abstract
Elasto-inertial microfluidics has drawn significant attention in recent years due to its enhanced capabilities compared to pure inertial systems in control of small microparticles. Previous investigations have focused mainly on the applications of elasto-inertial sorting, rather than studying its fundamentals. This is because of the complexity of simulation and analysis, due to the presence of viscoelastic force. There have been some investigative efforts on the mechanisms of elasto-inertial focusing in straight channels; however, these studies were limited to simple rectangular channels and neglected the effects of geometry and flow rates on focusing positions. Herein, for the first time, we experimentally and numerically explore the effects of elasticity accompanying channel cross-sectional geometry and sample flow rates on the focusing phenomenon in elasto-inertial systems. The results reveal that increasing the aspect ratio weakens the elastic force more than inertial force, causing a transition from one focusing position to two. In addition, they show that increasing the angle of a channel corner causes the elastic force to push the particles more efficiently toward the center over a larger area of the channel cross section. Following on from this, we proposed a new complex straight channel which demonstrates a tighter focusing band compared to other channel geometries. Finally, we focused Saccharomyces cerevisiae cells (3-5 μm) in the complex channel to showcase its capability in focusing small-size particles. We believe that this research work improves the understanding of focusing mechanisms in viscoelastic solutions and provides useful insights into the design of elasto-inertial microfluidic devices.
Collapse
Affiliation(s)
| | - Ali Mashhadian
- Department of Mechanical Engineering, Sharif University, Tehran, Iran
| | - Hamid Niazmand
- Department of Mechanical Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
| | - Mohsen Asadnia
- School of Engineering, Macquarie University, Sydney 2109, NSW, Australia
| | - Amir Razmjou
- UNESCO Center for Membrane Science and Technology, School of Chemical Science and Engineering, University of New South Wales, Sydney 2052, NSW, Australia
| | | |
Collapse
|
68
|
Moloudi R, Oh S, Yang C, Teo KL, Lam ATL, Ebrahimi Warkiani M, Win Naing M. Scaled-Up Inertial Microfluidics: Retention System for Microcarrier-Based Suspension Cultures. Biotechnol J 2019; 14:e1800674. [PMID: 30791214 DOI: 10.1002/biot.201800674] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Revised: 12/23/2018] [Indexed: 01/09/2023]
Abstract
Recently, particle concentration and filtration using inertial microfluidics have drawn attention as an alternative to membrane and centrifugal technologies for industrial applications, where the target particle size varies between 1 µm and 500 µm. Inevitably, the bigger particle size (>50 µm) mandates scaling up the channel cross-section or hydraulic diameter (DH > 0.5 mm). The Dean-coupled inertial focusing dynamics in spiral microchannels is studied broadly; however, the impacts of secondary flow on particle migration in a scaled-up spiral channel is not fully elucidated. The mechanism of particle focusing inside scaled-up rectangular and trapezoidal spiral channels (i.e., 5-10× bigger than conventional microchannels) with an aim to develop a continuous and clog-free microfiltration system for bioprocessing is studied in detail. Herein, a unique focusing based on inflection point without the aid of sheath flow is reported. This new focusing mechanism, observed in the scaled-up channels, out-performs the conventional focusing scenarios in the previously reported trapezoidal and rectangular channels. Finally, as a proof-of-concept, the utility of this device is showcased for the first time as a retention system for a cell-microcarrier (MC) suspension culture.
Collapse
Affiliation(s)
- Reza Moloudi
- School of Mechanical and Aerospace Engineering, Nanyang Technological University (NTU), 50 Nanyang Avenue, Singapore, 639798.,Bio-Manufacturing Programme, Singapore Institute of Manufacturing Technology (SIMTech), Agency for Science, Technology and Research (A*STAR), Innovis, Singapore, 138634
| | - Steve Oh
- Stem Cell Group, Bioprocessing Technology Institute, Agency for Science, Technology and Research (A*STAR), Centros, Singapore, 138668
| | - Chun Yang
- School of Mechanical and Aerospace Engineering, Nanyang Technological University (NTU), 50 Nanyang Avenue, Singapore, 639798
| | - Kim Leng Teo
- Stem Cell Group, Bioprocessing Technology Institute, Agency for Science, Technology and Research (A*STAR), Centros, Singapore, 138668
| | - Alan Tin-Lun Lam
- Stem Cell Group, Bioprocessing Technology Institute, Agency for Science, Technology and Research (A*STAR), Centros, Singapore, 138668
| | - Majid Ebrahimi Warkiani
- School of Biomedical Engineering, Center for Health Technologies, University of Technology Sydney, Ultimo, Sydney, NSW, 2007, Australia.,Institute of Molecular Medicine, Sechenov University, Moscow, Russia, 119146
| | - May Win Naing
- Bio-Manufacturing Programme, Singapore Institute of Manufacturing Technology (SIMTech), Agency for Science, Technology and Research (A*STAR), Innovis, Singapore, 138634
| |
Collapse
|
69
|
Xiang N, Zhang R, Han Y, Ni Z. A Multilayer Polymer-Film Inertial Microfluidic Device for High-Throughput Cell Concentration. Anal Chem 2019; 91:5461-5468. [DOI: 10.1021/acs.analchem.9b01116] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Nan Xiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing 211189, People’s Republic of China
| | - Rui Zhang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing 211189, People’s Republic of China
| | - Yu Han
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing 211189, People’s Republic of China
| | - Zhonghua Ni
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing 211189, People’s Republic of China
| |
Collapse
|
70
|
Rostami P, Kashaninejad N, Moshksayan K, Saidi MS, Firoozabadi B, Nguyen NT. Novel approaches in cancer management with circulating tumor cell clusters. JOURNAL OF SCIENCE: ADVANCED MATERIALS AND DEVICES 2019; 4:1-18. [DOI: 10.1016/j.jsamd.2019.01.006] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
|
71
|
Zhang X, Xia K, Ji A, Xiang N. A smart and portable micropump for stable liquid delivery. Electrophoresis 2019; 40:865-872. [DOI: 10.1002/elps.201800494] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Revised: 12/11/2018] [Accepted: 12/23/2018] [Indexed: 02/03/2023]
Affiliation(s)
- Xinjie Zhang
- College of Mechanical and Electrical Engineering; Hohai University; Changzhou P. R. China
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments; Southeast University; Nanjing P. R. China
| | - Kang Xia
- College of Mechanical and Electrical Engineering; Hohai University; Changzhou P. R. China
| | - Aimin Ji
- College of Mechanical and Electrical Engineering; Hohai University; Changzhou P. R. China
| | - Nan Xiang
- Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments; Southeast University; Nanjing P. R. China
| |
Collapse
|
72
|
Liu N, Petchakup C, Tay HM, Li KHH, Hou HW. Spiral Inertial Microfluidics for Cell Separation and Biomedical Applications. Bioanalysis 2019. [DOI: 10.1007/978-981-13-6229-3_5] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
|
73
|
Kwon T, Yao R, Hamel JFP, Han J. Continuous removal of small nonviable suspended mammalian cells and debris from bioreactors using inertial microfluidics. LAB ON A CHIP 2018; 18:2826-2837. [PMID: 30079919 DOI: 10.1039/c8lc00250a] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Removing nonviable cells from a cell suspension is crucial in biotechnology and biomanufacturing. Label-free microfluidic cell separation devices based on dielectrophoresis, acoustophoresis, and deterministic lateral displacement are used to remove nonviable cells. However, their volumetric throughputs and test cell concentrations are generally too low to be useful in typical bioreactors in biomanufacturing. In this study, we demonstrate the efficient removal of small (<10 μm) nonviable cells from bioreactors while maintaining viable cells using inertial microfluidic cell sorting devices and characterize their performance. Despite the size overlap between viable and nonviable cell populations, the devices demonstrated 3.5-28.0% dead cell removal efficiency with 88.3-83.6% removal purity as well as 97.8-99.8% live cell retention efficiency at 4 million cells per mL with 80% viability. Cascaded and parallel configurations increased the cell concentration capacity (10 million cells per mL) and volumetric throughput (6-8 mL min-1). The system can be used for the removal of small nonviable cells from a cell suspension during continuous perfusion cell culture operations.
Collapse
Affiliation(s)
- Taehong Kwon
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, USA.
| | | | | | | |
Collapse
|
74
|
Dixit C, Kadimisetty K, Rusling J. 3D-printed miniaturized fluidic tools in chemistry and biology. Trends Analyt Chem 2018; 106:37-52. [PMID: 32296252 PMCID: PMC7158885 DOI: 10.1016/j.trac.2018.06.013] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
3D printing (3DP), an additive manufacturing (AM) approach allowing for rapid prototyping and decentralized fabrication on-demand, has become a common method for creating parts or whole devices. The wide scope of the AM extends from organized sectors of construction, ornament, medical, and R&D industries to individual explorers attributed to the low cost, high quality printers along with revolutionary tools and polymers. While progress is being made but big manufacturing challenges are still there. Considering the quickly shifting narrative towards miniaturized analytical systems (MAS) we focus on the development/rapid prototyping and manufacturing of MAS with 3DP, and application dependent challenges in engineering designs and choice of the polymeric materials and provide an exhaustive background to the applications of 3DP in biology and chemistry. This will allow readers to perceive the most important features of AM in creating (i) various individual and modular components, and (ii) complete integrated tools.
Collapse
Affiliation(s)
- C.K. Dixit
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, United States
| | - K. Kadimisetty
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, United States
| | - J. Rusling
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, United States
- Institute of Materials Science, University of Connecticut, Storrs, CT 06269-3136, United States
- Department of Surgery and Neag Cancer Centre, UConn Health, Farmington, CT 06030, United States
- School of Chemistry, National University of Ireland at Galway, Galway, Ireland
| |
Collapse
|
75
|
Moloudi R, Oh S, Yang C, Teo KL, Lam ATL, Warkiani ME, Naing MW. Inertial-Based Filtration Method for Removal of Microcarriers from Mesenchymal Stem Cell Suspensions. Sci Rep 2018; 8:12481. [PMID: 30127526 PMCID: PMC6102204 DOI: 10.1038/s41598-018-31019-y] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Accepted: 08/07/2018] [Indexed: 01/21/2023] Open
Abstract
Rapidly evolving cell-based therapies towards clinical trials demand alternative approaches for efficient expansion of adherent cell types such as human mesenchymal stem cells (hMSCs). Using microcarriers (100-300 µm) in a stirred tank bioreactor offers considerably enhanced surface to volume ratio of culture environment. However, downstream purification of the harvested cell product needs to be addressed carefully due to distinctive features and fragility of these cell products. This work demonstrates a novel alternative approach which utilizes inertial focusing to separate microcarriers (MCs) from the final cell suspension. First, we systematically investigated MC focusing dynamics inside scaled-up curved channels with trapezoidal and rectangular cross-sections. A trapezoidal spiral channel with ultra-low-slope (Tan(α) = 0.0375) was found to contribute to strong MC focusing (~300 < Re < ~400) while managing high MC volume fractions up to ~1.68%. Accordingly, the high-throughput trapezoidal spiral channel successfully separated MCs from hMSC suspension with total cell yield~94% (after two passes) at a high volumetric flow rate of ~30 mL/min (Re~326.5).
Collapse
Affiliation(s)
- Reza Moloudi
- School of Mechanical and Aerospace Engineering, Nanyang Technological University (NTU), 50 Nanyang Avenue, Singapore, 639798, Singapore.,Bio-Manufacturing Programme, Singapore Institute of Manufacturing Technology (SIMTech), Agency for Science, Technology and Research (A*STAR), Innovis, Singapore, 138634, Singapore
| | - Steve Oh
- Stem Cell Group, Bioprocessing Technology Institute, Agency for Science, Technology and Research (A*STAR), Centros, Singapore, 138668, Singapore
| | - Chun Yang
- School of Mechanical and Aerospace Engineering, Nanyang Technological University (NTU), 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Kim Leng Teo
- Stem Cell Group, Bioprocessing Technology Institute, Agency for Science, Technology and Research (A*STAR), Centros, Singapore, 138668, Singapore
| | - Alan Tin-Lun Lam
- Stem Cell Group, Bioprocessing Technology Institute, Agency for Science, Technology and Research (A*STAR), Centros, Singapore, 138668, Singapore
| | - Majid Ebrahimi Warkiani
- School of Biomedical Engineering, Center for Health Technologies, University of Technology Sydney, Sydney, Ultimo NSW, 2007, Australia. .,Institute of Molecular Medicine, Sechenov First Moscow State University, Moscow, 119991, Russia.
| | - May Win Naing
- Bio-Manufacturing Programme, Singapore Institute of Manufacturing Technology (SIMTech), Agency for Science, Technology and Research (A*STAR), Innovis, Singapore, 138634, Singapore.
| |
Collapse
|
76
|
High-Throughput Microfluidic Sorting of Live Magnetotactic Bacteria. Appl Environ Microbiol 2018; 84:AEM.01308-18. [PMID: 29959254 DOI: 10.1128/aem.01308-18] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Accepted: 06/23/2018] [Indexed: 02/07/2023] Open
Abstract
Magnetic nanoparticles (MNPs) are useful for many biomedical applications, but it is challenging to synthetically produce them in large numbers with uniform properties and surface functionalization. Magnetotactic bacteria (MTB) produce magnetosomes with homogenous sizes, shapes, and magnetic properties. Consequently, there is interest in using MTB as biological factories for MNP production. Nonetheless, MTB can only be grown to low yields, and wild-type strains produce low numbers of MNPs/bacterium. There are also limited technologies to facilitate the selection of MTB with different magnetic contents, such as MTB with compromised and enhanced biomineralization ability. Here, we describe a magnetic microfluidic platform combined with transient cold/alkaline treatment to temporarily reduce the rapid flagellar motion of MTB without compromising their long-term proliferation and biomineralization ability for separating MTB on the basis of their magnetic contents. This strategy enables live MTB to be enriched, which, to the best of our knowledge, has not been achieved with another previously described magnetic microfluidic device that makes use of ferrofluid and heat. Our device also facilitates the high-throughput (25,000 cells/min) separation of wild-type Magnetospirillum gryphiswaldense (MSR-1) from nonmagnetic ΔmamAB MSR-1 mutants with a sensitivity of up to 80% and isolation purity of up to 95%, as confirmed with a gold-standard fluorescent-activated cell sorter (FACS) technique. This offers a 25-fold higher throughput than other previously described magnetic microfluidic platforms (1,000 cells/min). The device can also be used to isolate Magnetospirillum magneticum (AMB-1) mutants with different ranges of magnetosome numbers with efficiencies close to theoretical estimates. We believe this technology will facilitate the magnetic characterization of genetically engineered MTB for a variety of applications, including using MTB for large-scale, controlled MNP production.IMPORTANCE Our magnetic microfluidic technology can greatly facilitate biological applications with magnetotactic bacteria, from selection and screening to analysis. This technology will be of interest to microbiologists, chemists, and bioengineers who are interested in the biomineralization and selection of magnetotactic bacteria (MTB) for applications such as directed evolution and magnetogenetics.
Collapse
|
77
|
Vörös E, Piety NZ, Strachan BC, Lu M, Shevkoplyas SS. Centrifugation-free washing: A novel approach for removing immunoglobulin A from stored red blood cells. Am J Hematol 2018; 93:518-526. [PMID: 29285804 DOI: 10.1002/ajh.25026] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Revised: 12/20/2017] [Accepted: 12/26/2017] [Indexed: 01/28/2023]
Abstract
Washed red blood cells (RBCs) are indicated for immunoglobulin A (IgA) deficient recipients. Centrifugation-based cell processors commonly used by hospital blood banks cannot consistently reduce IgA below the recommended levels, hence double washing is frequently required. Here, we describe a prototype of a simple, portable, disposable system capable of washing stored RBCs without centrifugation, while reducing IgA below 0.05 mg/dL in a single run. Samples from RBC units (n = 8, leukoreduced, 4-6 weeks storage duration) were diluted with normal saline to a hematocrit of 10%, and then washed using either the prototype washing system, or via conventional centrifugation. The efficiency of the two washing methods was quantified and compared by measuring several key in vitro quality metrics. The prototype of the washing system was able to process stored RBCs at a rate of 300 mL/hour, producing a suspension of washed RBCs with 43 ± 3% hematocrit and 86 ± 7% cell recovery. Overall, the two washing methods performed similarly for most measured parameters, lowering the concentration of free hemoglobin by >4-fold and total free protein by >10-fold. Importantly, the new washing system reduced the IgA level to 0.02 ± 0.01 mg/mL, a concentration 5-fold lower than that produced by conventional centrifugation. This proof-of-concept study showed that centrifugation may be unnecessary for washing stored RBCs. A simple, disposable, centrifugation-free washing system could be particularly useful in smaller medical facilities and resource limited settings that may lack access to centrifugation-based cell processors.
Collapse
Affiliation(s)
- Eszter Vörös
- Department of Biomedical Engineering; University of Houston; Houston Texas 77204
| | - Nathaniel Z. Piety
- Department of Biomedical Engineering; University of Houston; Houston Texas 77204
| | - Briony C. Strachan
- Department of Biomedical Engineering; University of Houston; Houston Texas 77204
| | - Madeleine Lu
- Department of Biomedical Engineering; University of Houston; Houston Texas 77204
| | | |
Collapse
|
78
|
Xiang N, Shi X, Han Y, Shi Z, Jiang F, Ni Z. Inertial Microfluidic Syringe Cell Concentrator. Anal Chem 2018; 90:9515-9522. [DOI: 10.1021/acs.analchem.8b02201] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Nan Xiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Xin Shi
- Department of General Surgery, Zhongda Hospital, Southeast University, Nanjing, 210009, China
| | - Yu Han
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Zhiguo Shi
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Fengtao Jiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Zhonghua Ni
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| |
Collapse
|
79
|
Ryu H, Choi K, Qu Y, Kwon T, Lee JS, Han J. Label-free Neutrophil Enrichment from Patient-derived Airway Secretion Using Closed-loop Inertial Microfluidics. J Vis Exp 2018. [PMID: 29939191 DOI: 10.3791/57673] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
Airway secretions contain a large number of immune-related cells, e.g., neutrophils, macrophages, and lymphocytes, which can be used as a major resource to evaluate a variety of pulmonary diseases, both for research and clinical purposes. However, due to the heterogeneous and viscous nature of patient mucus, there is currently no reliable dissociation method that does not damage the host immune cells in the patient airway secretion. In this research, we introduce a sample preparation method that uses inertial microfluidics for the patient's immune assessment. Regardless of the heterogeneous fluidic properties of the clinical samples, the proposed method recovers more than 95% of neutrophils from airway secretion samples that are diluted 1,000-fold with milliliters of clean saline. By recirculating the concentrated output stream to the initial sample reservoir, a high concentration, recovery, and purity of the immune cells are provided; recirculation is considered a trade-off to the single-run syringe-based operation of inertial microfluidics. The closed-loop operation of spiral microfluidics provides leukocytes without physical or chemical disturbance, as demonstrated by the phorbol 12-myristate 13-acetate (PMA)-induced elastase release of sorted neutrophils.
Collapse
Affiliation(s)
- Hyunryul Ryu
- Research Laboratory of Electronics, Massachusetts Institute of Technology
| | - Kyungyong Choi
- Research Laboratory of Electronics, Massachusetts Institute of Technology; Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology
| | - Yanyan Qu
- Department of Medicine, University of Pittsburgh
| | - Taehong Kwon
- Research Laboratory of Electronics, Massachusetts Institute of Technology; Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology
| | - Janet S Lee
- Department of Medicine, University of Pittsburgh; Vascular Medicine Institute, University of Pittsburgh
| | - Jongyoon Han
- Research Laboratory of Electronics, Massachusetts Institute of Technology; Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology; Department of Biological Engineering, Massachusetts Institute of Technology;
| |
Collapse
|
80
|
|
81
|
Microfluidic cell sorting: Towards improved biocompatibility of extracorporeal lung assist devices. Sci Rep 2018; 8:8031. [PMID: 29795137 PMCID: PMC5966447 DOI: 10.1038/s41598-018-25977-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2018] [Accepted: 04/13/2018] [Indexed: 01/21/2023] Open
Abstract
Extracorporeal lung assist technology is one of the last options in critical care medicine to treat patients suffering from severe oxygenation and decarboxylation disorders. Platelet activation along with the consequent thrombus formation is a potentially life-threatening complication of this technique. To avoid platelet-dependent clot formation, this study aims at developing a microfluidic cell sorting chip that can bypass platelets prior to the membrane oxygenator of the extracorporeal lung assist device. The cell sorting chips were produced by maskless dip-in laser lithography, followed by soft lithography replication using PDMS. Citrated porcine whole blood with a clinically relevant haematocrit of 17% was used for the cell sorting experiments involving three different blood flow rates. The joint effects of flow focusing and hydrodynamic lifting forces within the cell sorting chip resulted in a reduction of up to 57% of the baseline platelet count. This cell sorting strategy is suitable for the continuous and label-free separation of red blood cells and platelets and is potentially applicable for increasing the biocompatibility and lifetime of current extracorporeal lung assist devices.
Collapse
|
82
|
|
83
|
Spiral Microchannels with Trapezoidal Cross Section Fabricated by Femtosecond Laser Ablation in Glass for the Inertial Separation of Microparticles. MICROMACHINES 2018; 9:mi9040171. [PMID: 30424104 PMCID: PMC6187241 DOI: 10.3390/mi9040171] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2018] [Revised: 03/18/2018] [Accepted: 03/20/2018] [Indexed: 11/29/2022]
Abstract
The fabrication and testing of spiral microchannels with a trapezoidal cross section for the passive separation of microparticles is reported in this article. In contrast to previously reported fabrication methods, the fabrication of trapezoidal spiral channels in glass substrates using a femtosecond laser is reported for the first time in this paper. Femtosecond laser ablation has been proposed as an accurate and fast prototyping method with the ability to create 3D features such as slanted-base channels. Moreover, the fabrication in borosilicate glass substrates can provide high optical transparency, thermal resistance, dimensional stability, and chemical inertness. Post-processing steps of the laser engraved glass substrate are also detailed in this paper including hydrogen fluoride (HF) dipping, chemical cleaning, surface activation, and thermal bonding. Optical 3D images of the fabricated chips confirmed a good fabrication accuracy and acceptable surface roughness. To evaluate the particle separation function of the microfluidic chip, 5 μm, 10 μm, and 15 μm particles were focused and recovered from the two outlets of the spiral channel. In conclusion, the new chemically inert separation chip can be utilized in biological or chemical processes where different sizes of cells or particles must be separated, i.e., red blood cells, circulating tumor cells, and technical particle suspensions.
Collapse
|
84
|
Choi K, Ryu H, Siddle KJ, Piantadosi A, Freimark L, Park DJ, Sabeti P, Han J. Negative Selection by Spiral Inertial Microfluidics Improves Viral Recovery and Sequencing from Blood. Anal Chem 2018; 90:4657-4662. [PMID: 29536737 PMCID: PMC6195311 DOI: 10.1021/acs.analchem.7b05200] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
In blood samples from patients with viral infection, it is often important to separate viral particles from human cells, for example, to minimize background in performing viral whole genome sequencing. Here, we present a microfluidic device that uses spiral inertial microfluidics with continuous circulation to separate host cells from viral particles and free nucleic acid. We demonstrate that this device effectively reduces white blood cells, red blood cells, and platelets from both whole blood and plasma samples with excellent recovery of viral nucleic acid. Furthermore, microfluidic separation leads to greater viral genome coverage and depth, highlighting an important application of this device in processing clinical samples for viral genome sequencing.
Collapse
Affiliation(s)
- Kyungyong Choi
- Research Laboratory of Electronics,Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA
| | | | - Katherine J Siddle
- Broad Institute of MIT and Harvard, 75 Ames Street, Cambridge, MA 02142, USA,Center for Systems Biology, Department of Organismic and Evolutionary Biology, Harvard University, Cambridge, MA, 02138, USA
| | - Anne Piantadosi
- Broad Institute of MIT and Harvard, 75 Ames Street, Cambridge, MA 02142, USA,Division of Infectious Disease, Department of Medicine, Massachusetts General Hospital, Boston, MA, 02114
| | - Lisa Freimark
- Broad Institute of MIT and Harvard, 75 Ames Street, Cambridge, MA 02142, USA
| | - Daniel J Park
- Broad Institute of MIT and Harvard, 75 Ames Street, Cambridge, MA 02142, USA
| | - Pardis Sabeti
- Broad Institute of MIT and Harvard, 75 Ames Street, Cambridge, MA 02142, USA,Center for Systems Biology, Department of Organismic and Evolutionary Biology, Harvard University, Cambridge, MA, 02138, USA,Department of Immunology and Infectious Disease, Harvard School of Public Health, Boston,Howard Hughes Medical Institute, Chevy Chase, Maryland, USA
| | - Jongyoon Han
- Research Laboratory of Electronics,Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA,Department of Biological Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA
| |
Collapse
|
85
|
Syed MS, Rafeie M, Vandamme D, Asadnia M, Henderson R, Taylor RA, Warkiani ME. Selective separation of microalgae cells using inertial microfluidics. BIORESOURCE TECHNOLOGY 2018; 252:91-99. [PMID: 29306136 DOI: 10.1016/j.biortech.2017.12.065] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Revised: 12/19/2017] [Accepted: 12/20/2017] [Indexed: 05/08/2023]
Abstract
Microalgae represent the most promising new source of biomass for the world's growing demands. However, the biomass productivity and quality is significantly decreased by the presence of bacteria or other invading microalgae species in the cultures. We therefore report a low-cost spiral-microchannel that can effectively separate and purify Tetraselmis suecica (lipid-rich microalgae) cultures from Phaeodactylum tricornutum (invasive diatom). Fluorescent polystyrene-microbeads of 6 μm and 10 μm diameters were first used as surrogate particles to optimize the microchannel design by mimicking the microalgae cell behaviour. Using the optimum flowrate, up to 95% of the P. tricornutum cells were separated from the culture without affecting the cell viability. This study shows, for the first time, the potential of inertial microfluidics to sort microalgae species with minimal size difference. Additionally, this approach can also be applied as a pre-sorting technique for water quality analysis.
Collapse
Affiliation(s)
- Maira S Syed
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Australia; Biomass Lab, School of Chemical Engineering, University of New South Wales, Australia.
| | - Mehdi Rafeie
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Australia
| | - Dries Vandamme
- Biomass Lab, School of Chemical Engineering, University of New South Wales, Australia; Laboratory for Aquatic Biology, KU Leuven, Campus Kulak, Belgium
| | - Mohsen Asadnia
- Department of Engineering, Macquarie University, Sydney, New South Wales, Australia
| | - Rita Henderson
- Biomass Lab, School of Chemical Engineering, University of New South Wales, Australia
| | - Robert A Taylor
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Australia; School of Photovoltaic and Renewable Energy Engineering, University of New South Wales, Australia
| | - Majid E Warkiani
- School of Biomedical Engineering, University of Technology Sydney, Australia; Center for Health Technologies, University of Technology Sydney, Australia.
| |
Collapse
|
86
|
Zhang X, Zhu Z, Xiang N, Long F, Ni Z. Automated Microfluidic Instrument for Label-Free and High-Throughput Cell Separation. Anal Chem 2018; 90:4212-4220. [DOI: 10.1021/acs.analchem.8b00539] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Xinjie Zhang
- School of Mechanical Engineering, and Jiangsu Key Laboratory
for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Zhixian Zhu
- School of Mechanical Engineering, and Jiangsu Key Laboratory
for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Nan Xiang
- School of Mechanical Engineering, and Jiangsu Key Laboratory
for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Feifei Long
- Nanjing Foreign Languages School, Nanjing, 210096, China
| | - Zhonghua Ni
- School of Mechanical Engineering, and Jiangsu Key Laboratory
for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| |
Collapse
|
87
|
Yan S, Li Y, Zhao Q, Yuan D, Yun G, Zhang J, Wen W, Tang SY, Li W. Liquid metal-based amalgamation-assisted lithography for fabrication of complex channels with diverse structures and configurations. LAB ON A CHIP 2018; 18:785-792. [PMID: 29424381 DOI: 10.1039/c8lc00047f] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Numerous lab-on-a-chip applications benefit from channels with complex structures and configurations in the areas of tissue engineering and clinical diagnostics. The current fabrication approaches require time-consuming, complicated processes and bulky, expensive facilities. In this work, we propose a novel method for the fabrication of complex channels with the assistance of amalgamation of liquid metal with copper tape. This new technique enables the rapid fabrication of liquid metal molds with various dimensions and diverse structures. Two proof-of-concept experiments were conducted to verify the utilization of this method. First, the channel replicated from the liquid metal mold is used to enhance the mixing performance of liquids flowing through the channel. Second, a channel with a semicircular cross-section is fabricated to achieve 3D focusing in a simple way. This proposed technique can be readily used for fabricating complex channels for a wide range of applications.
Collapse
Affiliation(s)
- Sheng Yan
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW 2522, Australia.
| | | | | | | | | | | | | | | | | |
Collapse
|
88
|
Yan S, Li Y, Zhao Q, Yuan D, Yun G, Tang SY, Li W. Enhanced particle self-ordering in a double-layer channel. Biomed Microdevices 2018; 20:23. [PMID: 29476424 DOI: 10.1007/s10544-018-0269-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
In this work, a novel double-layer microfluidic device for enhancing particle focusing was presented. The double-layer device consists of a channel with expansion-contraction array and periodical slanted grooves. The secondary flows induced by the grooves modulate the flow patterns in the expansion-contraction-array (ECA) channel, further affecting the particle migration. Compared with the single ECA channel, the double-layer channel can focus the particles over a wider range of flow rate. Due to the differentiation of lateral migration, the double-layer channel is able to distinguish the particles with different sizes. Furthermore, the equilibrium positions could be modulated by the orientation of grooves. This work demonstrates the possibility to enhance and adjust the inertial focusing in an ECA channel with the assistance of grooves, which may provide a simple and portable platform for downstream filtration, separation, and detection.
Collapse
Affiliation(s)
- Sheng Yan
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW, 2522, Australia.
| | - Yuxing Li
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW, 2522, Australia
| | - Qianbin Zhao
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW, 2522, Australia
| | - Dan Yuan
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW, 2522, Australia
| | - Guolin Yun
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW, 2522, Australia
| | - Shi-Yang Tang
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW, 2522, Australia
| | - Weihua Li
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW, 2522, Australia.
| |
Collapse
|
89
|
Bayat P, Rezai P. Semi-Empirical Estimation of Dean Flow Velocity in Curved Microchannels. Sci Rep 2017; 7:13655. [PMID: 29057886 PMCID: PMC5651805 DOI: 10.1038/s41598-017-13090-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Accepted: 09/18/2017] [Indexed: 01/13/2023] Open
Abstract
Curved and spiral microfluidic channels are widely used in particle and cell sorting applications. However, the average Dean velocity of secondary vortices which is an important design parameter in these devices cannot be estimated precisely with the current knowledge in the field. In this paper, we used co-flows of dyed liquids in curved microchannels with different radii of curvatures and monitored the lateral displacement of fluids using optical microscopy. A quantitative Switching Index parameter was then introduced to calculate the average Dean velocity in these channels. Additionally, we developed a validated numerical model to expand our investigations to elucidating the effects of channel hydraulic diameter, width, and height as well as fluid kinematic viscosity on Dean velocity. Accordingly, a non-dimensional comprehensive correlation was developed based on our numerical model and validated against experimental results. The proposed correlation can be used extensively for the design of curved microchannels for manipulation of fluids, particles, and biological substances in spiral microfluidic devices.
Collapse
Affiliation(s)
- Pouriya Bayat
- Department of Mechanical Engineering, York University, Toronto, ON, Canada
| | - Pouya Rezai
- Department of Mechanical Engineering, York University, Toronto, ON, Canada.
| |
Collapse
|
90
|
Kwon T, Prentice H, Oliveira JD, Madziva N, Warkiani ME, Hamel JFP, Han J. Microfluidic Cell Retention Device for Perfusion of Mammalian Suspension Culture. Sci Rep 2017; 7:6703. [PMID: 28751635 PMCID: PMC5532224 DOI: 10.1038/s41598-017-06949-8] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Accepted: 06/19/2017] [Indexed: 12/16/2022] Open
Abstract
Continuous production of biologics, a growing trend in the biopharmaceutical industry, requires a reliable and efficient cell retention device that also maintains cell viability. Current filtration methods, such as tangential flow filtration using hollow-fiber membranes, suffer from membrane fouling, leading to significant reliability and productivity issues such as low cell viability, product retention, and an increased contamination risk associated with filter replacement. We introduce a novel cell retention device based on inertial sorting for perfusion culture of suspended mammalian cells. The device was characterized in terms of cell retention capacity, biocompatibility, scalability, and long-term reliability. This technology was demonstrated using a high concentration (>20 million cells/mL) perfusion culture of an IgG1-producing Chinese hamster ovary (CHO) cell line for 18-25 days. The device demonstrated reliable and clog-free cell retention, high IgG1 recovery (>99%) and cell viability (>97%). Lab-scale perfusion cultures (350 mL) were used to demonstrate the technology, which can be scaled-out with parallel devices to enable larger scale operation. The new cell retention device is thus ideal for rapid perfusion process development in a biomanufacturing workflow.
Collapse
Affiliation(s)
- Taehong Kwon
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| | | | - Jonas De Oliveira
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Nyasha Madziva
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Majid Ebrahimi Warkiani
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, Australia
| | - Jean-François P Hamel
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.
| | - Jongyoon Han
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA.
- BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, Singapore, Singapore.
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.
| |
Collapse
|
91
|
Shakeel Syed M, Rafeie M, Henderson R, Vandamme D, Asadnia M, Ebrahimi Warkiani M. A 3D-printed mini-hydrocyclone for high throughput particle separation: application to primary harvesting of microalgae. LAB ON A CHIP 2017; 17:2459-2469. [PMID: 28695927 DOI: 10.1039/c7lc00294g] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
The separation of micro-sized particles in a continuous flow is crucial part of many industrial processes, from biopharmaceutical manufacturing to water treatment. Conventional separation techniques such as centrifugation and membrane filtration are largely limited by factors such as clogging, processing time and operation efficiency. Microfluidic based techniques have been gaining great attention in recent years as efficient and powerful approaches for particle-liquid separation. Yet the production of such systems using standard micro-fabrication techniques is proven to be tedious, costly and have cumbersome user interfaces, which all render commercialization difficult. Here, we demonstrate the design, fabrication and evaluation based on CFD simulation as well as experimentation of 3D-printed miniaturized hydrocyclones with smaller cut-size for high-throughput particle/cell sorting. The characteristics of the mini-cyclones were numerically investigated using computational fluid dynamics (CFD) techniques previously revealing that reduction in the size of the cyclone results in smaller cut-size of the particles. To showcase its utility, high-throughput algae harvesting from the medium with low energy input is demonstrated for the marine microalgae Tetraselmis suecica. Final microalgal biomass concentration was increased by 7.13 times in 11 minutes of operation time using our designed hydrocyclone (HC-1). We expect that this elegant approach can surmount the shortcomings of other microfluidic technologies such as clogging, low-throughput, cost and difficulty in operation. By moving away from production of planar microfluidic systems using conventional microfabrication techniques and embracing 3D-printing technology for construction of discrete elements, we envision 3D-printed mini-cyclones can be part of a library of standardized active and passive microfluidic components, suitable for particle-liquid separation.
Collapse
Affiliation(s)
- Maira Shakeel Syed
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW 2052, Australia.
| | | | | | | | | | | |
Collapse
|
92
|
Collins DJ, Khoo BL, Ma Z, Winkler A, Weser R, Schmidt H, Han J, Ai Y. Selective particle and cell capture in a continuous flow using micro-vortex acoustic streaming. LAB ON A CHIP 2017; 17:1769-1777. [PMID: 28394386 DOI: 10.1039/c7lc00215g] [Citation(s) in RCA: 62] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Acoustic streaming has emerged as a promising technique for refined microscale manipulation, where strong rotational flow can give rise to particle and cell capture. In contrast to hydrodynamically generated vortices, acoustic streaming is rapidly tunable, highly scalable and requires no external pressure source. Though streaming is typically ignored or minimized in most acoustofluidic systems that utilize other acoustofluidic effects, we maximize the effect of acoustic streaming in a continuous flow using a high-frequency (381 MHz), narrow-beam focused surface acoustic wave. This results in rapid fluid streaming, with velocities orders of magnitude greater than that of the lateral flow, to generate fluid vortices that extend the entire width of a 400 μm wide microfluidic channel. We characterize the forces relevant for vortex formation in a combined streaming/lateral flow system, and use these acoustic streaming vortices to selectively capture 2 μm from a mixed suspension with 1 μm particles and human breast adenocarcinoma cells (MDA-231) from red blood cells.
Collapse
Affiliation(s)
- David J Collins
- Pillar of Engineering Product Development, Singapore University of Technology and Design, Singapore 487372, Singapore.
| | | | | | | | | | | | | | | |
Collapse
|
93
|
Ryu H, Choi K, Qu Y, Kwon T, Lee JS, Han J. Patient-Derived Airway Secretion Dissociation Technique To Isolate and Concentrate Immune Cells Using Closed-Loop Inertial Microfluidics. Anal Chem 2017; 89:5549-5556. [PMID: 28402103 DOI: 10.1021/acs.analchem.7b00610] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Assessment of airway secretion cells, both for research and clinical purposes, is a highly desired goal in patients with acute and chronic pulmonary diseases. However, lack of proper cell isolation and enrichment techniques hinder downstream evaluation and characterization of cells found in airway secretions. Here, we demonstrate a novel enrichment method to capture immune-related cells from clinical airway secretions using closed-loop separation of spiral inertial microfluidics (C-sep). By recirculating the output focusing stream back to the input reservoir and running continuously with a high flow processing rate, one can achieve optimal concentration, recovery and purity of airway immune cells from a large volume of diluent, which was not readily possible in the single-pass operation. Our method reproducibly recovers 94.0% of polymorphonuclear leukocytes (PMNs), with up to 105 PMNs in clear diluted buffer from 50 μL of airway secretions obtained from mechanically ventilated patients. We show that C-sep isolated PMNs show higher neutrophil elastase (NE) release following activation by phorbol 12-myristate 13-acetate (PMA) than cells isolated by conventional mucolytic method. By capturing cells without chemically disrupting their potential function, our method is expected to expand the possibility of clinical in vitro cell based biological assays for various pulmonary diseases such as acute respiratory distress syndrome, pneumonia, cystic fibrosis, and bronchiectasis.
Collapse
Affiliation(s)
- Hyunryul Ryu
- Research Laboratory of Electronics, ‡Department of Electrical Engineering and Computer Science, §Department of Biological Engineering, Massachusetts Institute of Technology , 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States.,Department of Medicine and the ⊥Vascular Medicine Institute, University of Pittsburgh , NW628 Montefiore University Hospital, 3459 Fifth Avenue, Pittsburgh, Pennsylvania 15213, United States
| | - Kyungyong Choi
- Research Laboratory of Electronics, ‡Department of Electrical Engineering and Computer Science, §Department of Biological Engineering, Massachusetts Institute of Technology , 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States.,Department of Medicine and the ⊥Vascular Medicine Institute, University of Pittsburgh , NW628 Montefiore University Hospital, 3459 Fifth Avenue, Pittsburgh, Pennsylvania 15213, United States
| | - Yanyan Qu
- Research Laboratory of Electronics, ‡Department of Electrical Engineering and Computer Science, §Department of Biological Engineering, Massachusetts Institute of Technology , 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States.,Department of Medicine and the ⊥Vascular Medicine Institute, University of Pittsburgh , NW628 Montefiore University Hospital, 3459 Fifth Avenue, Pittsburgh, Pennsylvania 15213, United States
| | - Taehong Kwon
- Research Laboratory of Electronics, ‡Department of Electrical Engineering and Computer Science, §Department of Biological Engineering, Massachusetts Institute of Technology , 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States.,Department of Medicine and the ⊥Vascular Medicine Institute, University of Pittsburgh , NW628 Montefiore University Hospital, 3459 Fifth Avenue, Pittsburgh, Pennsylvania 15213, United States
| | - Janet S Lee
- Research Laboratory of Electronics, ‡Department of Electrical Engineering and Computer Science, §Department of Biological Engineering, Massachusetts Institute of Technology , 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States.,Department of Medicine and the ⊥Vascular Medicine Institute, University of Pittsburgh , NW628 Montefiore University Hospital, 3459 Fifth Avenue, Pittsburgh, Pennsylvania 15213, United States
| | - Jongyoon Han
- Research Laboratory of Electronics, ‡Department of Electrical Engineering and Computer Science, §Department of Biological Engineering, Massachusetts Institute of Technology , 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, United States.,Department of Medicine and the ⊥Vascular Medicine Institute, University of Pittsburgh , NW628 Montefiore University Hospital, 3459 Fifth Avenue, Pittsburgh, Pennsylvania 15213, United States
| |
Collapse
|
94
|
|
95
|
Robinson M, Marks H, Hinsdale T, Maitland K, Coté G. Rapid isolation of blood plasma using a cascaded inertial microfluidic device. BIOMICROFLUIDICS 2017; 11:024109. [PMID: 28405258 PMCID: PMC5367146 DOI: 10.1063/1.4979198] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Accepted: 03/14/2017] [Indexed: 05/21/2023]
Abstract
Blood, saliva, mucus, sweat, sputum, and other biological fluids are often hindered in their ability to be used in point-of-care (POC) diagnostics because their assays require some form of off-site sample pre-preparation to effectively separate biomarkers from larger components such as cells. The rapid isolation, identification, and quantification of proteins and other small molecules circulating in the blood plasma from larger interfering molecules are therefore particularly important factors for optical blood diagnostic tests, in particular, when using optical approaches that incur spectroscopic interference from hemoglobin-rich red blood cells (RBCs). In this work, a sequential spiral polydimethylsiloxane (PDMS) microfluidic device for rapid (∼1 min) on-chip blood cell separation is presented. The chip utilizes Dean-force induced migration via two 5-loop Archimedean spirals in series. The chip was characterized in its ability to filter solutions containing fluorescent beads and silver nanoparticles and further using blood solutions doped with a fluorescent protein. Through these experiments, both cellular and small molecule behaviors in the chip were assessed. The results exhibit an average RBC separation efficiency of ∼99% at a rate of 5.2 × 106 cells per second while retaining 95% of plasma components. This chip is uniquely suited for integration within a larger point-of-care diagnostic system for the testing of blood plasma, and the use of multiple filtering spirals allows for the tuning of filtering steps, making this device and the underlying technique applicable for a wide range of separation applications.
Collapse
Affiliation(s)
- M Robinson
- Department of Biomedical Engineering, Texas A&M University , College Station, Texas 77843, USA
| | - H Marks
- Department of Biomedical Engineering, Texas A&M University , College Station, Texas 77843, USA
| | - T Hinsdale
- Department of Biomedical Engineering, Texas A&M University , College Station, Texas 77843, USA
| | | | | |
Collapse
|
96
|
Feng SL, Skelley AM, Anwer AG, Liu G, Inglis DW. Maximizing particle concentration in deterministic lateral displacement arrays. BIOMICROFLUIDICS 2017; 11:024121. [PMID: 28503245 PMCID: PMC5409848 DOI: 10.1063/1.4981014] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2017] [Accepted: 04/04/2017] [Indexed: 05/11/2023]
Abstract
We present an improvement to deterministic lateral displacement arrays, which allows higher particle concentration enhancement. We correct and extend previous equations to a mirror-symmetric boundary. This approach allows particles to be concentrated into a central channel, no wider than the surrounding gaps, thereby maximizing the particle enrichment. The resulting flow patterns were, for the first time, experimentally measured. The performance of the device with hard micro-spheres and cells was investigated. The observed flow patterns show important differences from our model and from an ideal pattern. The 18 μm gap device showed 11-fold enrichment of 7 μm particles and nearly perfect enrichment-of more than 50-fold-for 10 μm particles and Jurkat cells. This work shows a clear path to achieve higher-than-ever particle concentration enhancement in a deterministic microfluidic separation system.
Collapse
Affiliation(s)
| | - Alison M Skelley
- GPB Scientific LLC, 800 East Leigh St., Richmond, Virginia 23219, USA
| | | | | | | |
Collapse
|
97
|
A comparison of microfiltration and inertia-based microfluidics for large scale suspension separation. Sep Purif Technol 2017. [DOI: 10.1016/j.seppur.2016.09.018] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
98
|
Go T, Byeon H, Lee SJ. Focusing and alignment of erythrocytes in a viscoelastic medium. Sci Rep 2017; 7:41162. [PMID: 28117428 PMCID: PMC5259727 DOI: 10.1038/srep41162] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2016] [Accepted: 12/14/2016] [Indexed: 12/30/2022] Open
Abstract
Viscoelastic fluid flow-induced cross-streamline migration has recently received considerable attention because this process provides simple focusing and alignment over a wide range of flow rates. The lateral migration of particles depends on the channel geometry and physicochemical properties of particles. In this study, digital in-line holographic microscopy (DIHM) is employed to investigate the lateral migration of human erythrocytes induced by viscoelastic fluid flow in a rectangular microchannel. DIHM provides 3D spatial distributions of particles and information on particle orientation in the microchannel. The elastic forces generated in the pressure-driven flows of a viscoelastic fluid push suspended particles away from the walls and enforce erythrocytes to have a fixed orientation. Blood cell deformability influences the lateral focusing and fixed orientation in the microchannel. Different from rigid spheres and hardened erythrocytes, deformable normal erythrocytes disperse from the channel center plane, as the flow rate increases. Furthermore, normal erythrocytes have a higher angle of inclination than hardened erythrocytes in the region near the side-walls of the channel. These results may guide the label-free diagnosis of hematological diseases caused by abnormal erythrocyte deformability.
Collapse
Affiliation(s)
- Taesik Go
- Center for Biofluid and Biomimic Research, Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 790-784, South Korea
| | - Hyeokjun Byeon
- Center for Biofluid and Biomimic Research, Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 790-784, South Korea
| | - Sang Joon Lee
- Center for Biofluid and Biomimic Research, Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 790-784, South Korea
| |
Collapse
|
99
|
Yousuff CM, Ho ETW, Hussain K. I, Hamid NHB. Microfluidic Platform for Cell Isolation and Manipulation Based on Cell Properties. MICROMACHINES 2017. [PMCID: PMC6189901 DOI: 10.3390/mi8010015] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Caffiyar Mohamed Yousuff
- Correspondence: (C.M.Y.); (E.T.W.H.); (N.H.B.H.); Tel.: +60-1678-50269 (C.M.Y.); +60-1238-17752 (E.T.W.H.); +60-1927-87127 (N.H.B.H.)
| | - Eric Tatt Wei Ho
- Correspondence: (C.M.Y.); (E.T.W.H.); (N.H.B.H.); Tel.: +60-1678-50269 (C.M.Y.); +60-1238-17752 (E.T.W.H.); +60-1927-87127 (N.H.B.H.)
| | | | - Nor Hisham B. Hamid
- Correspondence: (C.M.Y.); (E.T.W.H.); (N.H.B.H.); Tel.: +60-1678-50269 (C.M.Y.); +60-1238-17752 (E.T.W.H.); +60-1927-87127 (N.H.B.H.)
| |
Collapse
|
100
|
Cascading and Parallelising Curvilinear Inertial Focusing Systems for High Volume, Wide Size Distribution, Separation and Concentration of Particles. Sci Rep 2016; 6:36386. [PMID: 27808244 PMCID: PMC5093461 DOI: 10.1038/srep36386] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2016] [Accepted: 10/14/2016] [Indexed: 01/09/2023] Open
Abstract
Inertial focusing is a microfluidic based separation and concentration technology that has expanded rapidly in the last few years. Throughput is high compared to other microfluidic approaches although sample volumes have typically remained in the millilitre range. Here we present a strategy for achieving rapid high volume processing with stacked and cascaded inertial focusing systems, allowing for separation and concentration of particles with a large size range, demonstrated here from 30 μm–300 μm. The system is based on curved channels, in a novel toroidal configuration and a stack of 20 devices has been shown to operate at 1 L/min. Recirculation allows for efficient removal of large particles whereas a cascading strategy enables sequential removal of particles down to a final stage where the target particle size can be concentrated. The demonstration of curved stacked channels operating in a cascaded manner allows for high throughput applications, potentially replacing filtration in applications such as environmental monitoring, industrial cleaning processes, biomedical and bioprocessing and many more.
Collapse
|