51
|
Gong K, Kim K, Cui J, Wu D, Li Q. The Evolution of Image Reconstruction in PET: From Filtered Back-Projection to Artificial Intelligence. PET Clin 2021; 16:533-542. [PMID: 34537129 DOI: 10.1016/j.cpet.2021.06.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
PET can provide functional images revealing physiologic processes in vivo. Although PET has many applications, there are still some limitations that compromise its precision: the absorption of photons in the body causes signal attenuation; the dead-time limit of system components leads to the loss of the count rate; the scattered and random events received by the detector introduce additional noise; the characteristics of the detector limit the spatial resolution; and the low signal-to-noise ratio caused by the scan-time limit (eg, dynamic scans) and dose concern. The early PET reconstruction methods are analytical approaches based on an idealized mathematical model.
Collapse
Affiliation(s)
- Kuang Gong
- Department of Radiology, Center for Advanced Medical Computing and Analysis, Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Kyungsang Kim
- Department of Radiology, Center for Advanced Medical Computing and Analysis, Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Jianan Cui
- Department of Radiology, Center for Advanced Medical Computing and Analysis, Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Dufan Wu
- Department of Radiology, Center for Advanced Medical Computing and Analysis, Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Quanzheng Li
- Department of Radiology, Center for Advanced Medical Computing and Analysis, Gordon Center for Medical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
52
|
Xie Z, Li T, Zhang X, Qi W, Asma E, Qi J. Anatomically aided PET image reconstruction using deep neural networks. Med Phys 2021; 48:5244-5258. [PMID: 34129690 PMCID: PMC8510002 DOI: 10.1002/mp.15051] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 05/07/2021] [Accepted: 06/02/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The developments of PET/CT and PET/MR scanners provide opportunities for improving PET image quality by using anatomical information. In this paper, we propose a novel co-learning three-dimensional (3D) convolutional neural network (CNN) to extract modality-specific features from PET/CT image pairs and integrate complementary features into an iterative reconstruction framework to improve PET image reconstruction. METHODS We used a pretrained deep neural network to represent PET images. The network was trained using low-count PET and CT image pairs as inputs and high-count PET images as labels. This network was then incorporated into a constrained maximum likelihood framework to regularize PET image reconstruction. Two different network structures were investigated for the integration of anatomical information from CT images. One was a multichannel CNN, which treated PET and CT volumes as separate channels of the input. The other one was multibranch CNN, which implemented separate encoders for PET and CT images to extract latent features and fed the combined latent features into a decoder. Using computer-based Monte Carlo simulations and two real patient datasets, the proposed method has been compared with existing methods, including the maximum likelihood expectation maximization (MLEM) reconstruction, a kernel-based reconstruction and a CNN-based deep penalty method with and without anatomical guidance. RESULTS Reconstructed images showed that the proposed constrained ML reconstruction approach produced higher quality images than the competing methods. The tumors in the lung region have higher contrast in the proposed constrained ML reconstruction than in the CNN-based deep penalty reconstruction. The image quality was further improved by incorporating the anatomical information. Moreover, the liver standard deviation was lower in the proposed approach than all the competing methods at a matched lesion contrast. CONCLUSIONS The supervised co-learning strategy can improve the performance of constrained maximum likelihood reconstruction. Compared with existing techniques, the proposed method produced a better lesion contrast versus background standard deviation trade-off curve, which can potentially improve lesion detection.
Collapse
Affiliation(s)
- Zhaoheng Xie
- Department of Biomedical Engineering, University of
California, Davis, CA, USA
| | - Tiantian Li
- Department of Biomedical Engineering, University of
California, Davis, CA, USA
| | - Xuezhu Zhang
- Department of Biomedical Engineering, University of
California, Davis, CA, USA
| | - Wenyuan Qi
- Canon Medical Research USA, Inc., Vernon Hills, IL,
USA
| | - Evren Asma
- Canon Medical Research USA, Inc., Vernon Hills, IL,
USA
| | - Jinyi Qi
- Department of Biomedical Engineering, University of
California, Davis, CA, USA
| |
Collapse
|
53
|
Li S, Wang G. Modified kernel MLAA using autoencoder for PET-enabled dual-energy CT. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2021; 379:20200204. [PMID: 34218670 PMCID: PMC8255948 DOI: 10.1098/rsta.2020.0204] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Accepted: 03/04/2021] [Indexed: 06/13/2023]
Abstract
Combined use of PET and dual-energy CT provides complementary information for multi-parametric imaging. PET-enabled dual-energy CT combines a low-energy X-ray CT image with a high-energy γ-ray CT (GCT) image reconstructed from time-of-flight PET emission data to enable dual-energy CT material decomposition on a PET/CT scanner. The maximum-likelihood attenuation and activity (MLAA) algorithm has been used for GCT reconstruction but suffers from noise. Kernel MLAA exploits an X-ray CT image prior through the kernel framework to guide GCT reconstruction and has demonstrated substantial improvements in noise suppression. However, similar to other kernel methods for image reconstruction, the existing kernel MLAA uses image intensity-based features to construct the kernel representation, which is not always robust and may lead to suboptimal reconstruction with artefacts. In this paper, we propose a modified kernel method by using an autoencoder convolutional neural network (CNN) to extract an intrinsic feature set from the X-ray CT image prior. A computer simulation study was conducted to compare the autoencoder CNN-derived feature representation with raw image patches for evaluation of kernel MLAA for GCT image reconstruction and dual-energy multi-material decomposition. The results show that the autoencoder kernel MLAA method can achieve a significant image quality improvement for GCT and material decomposition as compared to the existing kernel MLAA algorithm. A weakness of the proposed method is its potential over-smoothness in a bone region, indicating the importance of further optimization in future work. This article is part of the theme issue 'Synergistic tomographic image reconstruction: part 2'.
Collapse
Affiliation(s)
- Siqi Li
- University of California Davis Medical Center, Department of Radiology, Saramento, CA, USA
| | - Guobao Wang
- University of California Davis Medical Center, Department of Radiology, Saramento, CA, USA
| |
Collapse
|
54
|
Zuo Y, López JE, Smith TW, Foster CC, Carson RE, Badawi RD, Wang G. Multiparametric cardiac 18F-FDG PET in humans: pilot comparison of FDG delivery rate with 82Rb myocardial blood flow. Phys Med Biol 2021; 66. [PMID: 34280905 DOI: 10.1088/1361-6560/ac15a6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Accepted: 07/14/2021] [Indexed: 02/01/2023]
Abstract
Myocardial blood flow (MBF) and flow reserve are usually quantified in the clinic with positron emission tomography (PET) using a perfusion-specific radiotracer (e.g.82Rb-chloride). However, the clinical accessibility of existing perfusion tracers remains limited. Meanwhile,18F-fluorodeoxyglucose (FDG) is a commonly used radiotracer for PET metabolic imaging without similar limitations. In this paper, we explore the potential of18F-FDG for myocardial perfusion imaging by comparing the myocardial FDG delivery rateK1with MBF as determined by dynamic82Rb PET in fourteen human subjects with heart disease. Two sets of FDGK1were derived from one-hour dynamic FDG scans. One was the original FDGK1estimates and the other was the correspondingK1values that were linearly normalized for blood glucose levels. A generalized Renkin-Crone model was used to fit FDGK1with Rb MBF, which then allowed for a nonlinear extraction fraction correction for converting FDGK1to MBF. The linear correlation between FDG-derived MBF and Rb MBF was moderate (r= 0.79) before the glucose normalization and became much improved (r> 0.9) after glucose normalization. The extraction fraction of FDG was also similar to that of Rb-chloride in the myocardium. The results from this pilot study suggest that dynamic cardiac FDG-PET with tracer kinetic modeling has the potential to provide MBF in addition to its conventional use for metabolic imaging.
Collapse
Affiliation(s)
- Yang Zuo
- Department of Radiology, University of California Davis Medical Center, Sacramento, CA 95817, United States of America
| | - Javier E López
- Department of Internal Medicine, University of California Davis Medical Center, Sacramento, CA 95817, United States of America
| | - Thomas W Smith
- Department of Internal Medicine, University of California Davis Medical Center, Sacramento, CA 95817, United States of America
| | - Cameron C Foster
- Department of Radiology, University of California Davis Medical Center, Sacramento, CA 95817, United States of America
| | - Richard E Carson
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT 06520, United States of America
| | - Ramsey D Badawi
- Department of Radiology, University of California Davis Medical Center, Sacramento, CA 95817, United States of America.,Department of Biomedical Engineering, University of California at Davis, United States of America
| | - Guobao Wang
- Department of Radiology, University of California Davis Medical Center, Sacramento, CA 95817, United States of America
| |
Collapse
|
55
|
Gao D, Zhang X, Zhou C, Fan W, Zeng T, Yang Q, Yuan J, He Q, Liang D, Liu X, Yang Y, Zheng H, Hu Z. MRI-aided kernel PET image reconstruction method based on texture features. Phys Med Biol 2021; 66. [PMID: 34192685 DOI: 10.1088/1361-6560/ac1024] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Accepted: 06/30/2021] [Indexed: 11/11/2022]
Abstract
We investigate the reconstruction of low-count positron emission tomography (PET) projection, which is an important, but challenging, task. Using the texture feature extraction method of radiomics, i.e. the gray-level co-occurrence matrix (GLCM), texture features can be extracted from magnetic resonance imaging images with high-spatial resolution. In this work, we propose a kernel reconstruction method combining autocorrelation texture features derived from the GLCM. The new kernel function includes the correlations of both the intensity and texture features from the prior image. By regarding the GLCM as a discrete approximation of a probability density function, the asymptotically gray-level-invariant autocorrelation texture feature is generated, which can maintain the accuracy of texture features extracted from small image regions by reducing the number of quantized image gray levels. A computer simulation shows that the proposed method can effectively reduce the noise in the reconstructed image compared to the maximum likelihood expectation maximum method and improve the image quality and tumor region accuracy compared to the original kernel method for low-count PET reconstruction. A simulation study on clinical patient images also shows that the proposed method can improve the whole image quality and that the reconstruction of a high-uptake lesion is more accurate than that achieved by the original kernel method.
Collapse
Affiliation(s)
- Dongfang Gao
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen 518055, People's Republic of China
| | - Xu Zhang
- Department of Nuclear Medicine, Sun Yat-sen University Cancer Center, Guangzhou 510060, People's Republic of China
| | - Chao Zhou
- Department of Nuclear Medicine, Sun Yat-sen University Cancer Center, Guangzhou 510060, People's Republic of China
| | - Wei Fan
- Department of Nuclear Medicine, Sun Yat-sen University Cancer Center, Guangzhou 510060, People's Republic of China
| | - Tianyi Zeng
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen 518055, People's Republic of China
| | - Qian Yang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen 518055, People's Republic of China
| | - Jianmin Yuan
- Central Research Institute, Shanghai United Imaging Healthcare, Shanghai 201807, People's Republic of China
| | - Qiang He
- Central Research Institute, Shanghai United Imaging Healthcare, Shanghai 201807, People's Republic of China
| | - Dong Liang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen 518055, People's Republic of China
| | - Xin Liu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen 518055, People's Republic of China
| | - Yongfeng Yang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen 518055, People's Republic of China
| | - Hairong Zheng
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen 518055, People's Republic of China
| | - Zhanli Hu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen 518055, People's Republic of China
| |
Collapse
|
56
|
Wang H, Huang Z, Zhang Q, Gao D, OuYang Z, Liang D, Liu X, Yang Y, Zheng H, Hu Z. Technical note: A preliminary study of dual-tracer PET image reconstruction guided by FDG and/or MR kernels. Med Phys 2021; 48:5259-5271. [PMID: 34252216 DOI: 10.1002/mp.15089] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 06/22/2021] [Accepted: 06/23/2021] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Clinically, single radiotracer positron emission tomography (PET) imaging is a commonly used examination method; however, since each radioactive tracer reflects the information of only one kind of cell, it easily causes false negatives or false positives in disease diagnosis. Therefore, reasonably combining two or more radiotracers is recommended to improve the accuracy of diagnosis and the sensitivity and specificity of the disease when conditions permit. METHODS This paper proposes incorporating 18 F-fluorodeoxyglucose (FDG) as a higher-quality PET image to guide the reconstruction of other lower-count 11 C-methionine (MET) PET datasets to compensate for the lower image quality by a popular kernel algorithm. Specifically, the FDG prior is needed to extract kernel features, and these features were used to build a kernel matrix using a k-nearest-neighbor (kNN) search for MET image reconstruction. We created a 2-D brain phantom to validate the proposed method by simulating sinogram data containing Poisson random noise and quantitatively compared the performance of the proposed FDG-guided kernelized expectation maximization (KEM) method with the performance of Gaussian and non-local means (NLM) smoothed maximum likelihood expectation maximization (MLEM), MR-guided KEM, and multi-guided-S KEM algorithms. Mismatch experiments between FDG/MR and MET data were also carried out to investigate the outcomes of possible clinical situations. RESULTS In the simulation study, the proposed method outperformed the other algorithms by at least 3.11% in the signal-to-noise ratio (SNR) and 0.68% in the contrast recovery coefficient (CRC), and it reduced the mean absolute error (MAE) by 8.07%. Regarding the tumor in the reconstructed image, the proposed method contained more pathological information. Furthermore, the proposed method was still superior to the MR-guided KEM method in the mismatch experiments. CONCLUSIONS The proposed FDG-guided KEM algorithm can effectively utilize and compensate for the tissue metabolism information obtained from dual-tracer PET to maximize the advantages of PET imaging.
Collapse
Affiliation(s)
- Haiyan Wang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Beijing, China
| | - Zhenxing Huang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Qiyang Zhang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Dongfang Gao
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Zhanglei OuYang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Dong Liang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen, China
| | - Xin Liu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen, China
| | - Yongfeng Yang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen, China
| | - Hairong Zheng
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen, China
| | - Zhanli Hu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen, China
| |
Collapse
|
57
|
Xie N, Gong K, Guo N, Qin Z, Wu Z, Liu H, Li Q. Rapid high-quality PET Patlak parametric image generation based on direct reconstruction and temporal nonlocal neural network. Neuroimage 2021; 240:118380. [PMID: 34252526 DOI: 10.1016/j.neuroimage.2021.118380] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 07/04/2021] [Accepted: 07/07/2021] [Indexed: 11/25/2022] Open
Abstract
Parametric imaging based on dynamic positron emission tomography (PET) has wide applications in neurology. Compared to indirect methods, direct reconstruction methods, which reconstruct parametric images directly from the raw PET data, have superior image quality due to better noise modeling and richer information extracted from the PET raw data. For low-dose scenarios, the advantages of direct methods are more obvious. However, the wide adoption of direct reconstruction is inevitably impeded by the excessive computational demand and deficiency of the accessible raw data. In addition, motion modeling inside dynamic PET image reconstruction raises more computational challenges for direct reconstruction methods. In this work, we focused on the 18F-FDG Patlak model, and proposed a data-driven approach which can estimate the motion corrected full-dose direct Patlak images from the dynamic PET reconstruction series, based on a proposed novel temporal non-local convolutional neural network. During network training, direct reconstruction with motion correction based on full-dose dynamic PET sinograms was performed to obtain the training labels. The reconstructed full-dose /low-dose dynamic PET images were supplied as the network input. In addition, a temporal non-local block based on the dynamic PET images was proposed to better recover the structural information and reduce the image noise. During testing, the proposed network can directly output high-quality Patlak parametric images from the full-dose /low-dose dynamic PET images in seconds. Experiments based on 15 full-dose and 15 low-dose 18F-FDG brain datasets were conducted and analyzed to validate the feasibility of the proposed framework. Results show that the proposed framework can generate better image quality than reference methods.
Collapse
Affiliation(s)
- Nuobei Xie
- College of Optical Science and Engineering, Zhejiang University, 38 Zheda Road, Building 3, Hangzhou 310027, China; Center for Advanced Medical Computing and Analysis, Massachusetts General Hospital and Harvard Medical School, 55 Fruit St, White 427, 125 Nashua Street, Suite 660, Boston, MA 02114, United States.
| | - Kuang Gong
- Center for Advanced Medical Computing and Analysis, Massachusetts General Hospital and Harvard Medical School, 55 Fruit St, White 427, 125 Nashua Street, Suite 660, Boston, MA 02114, United States.
| | - Ning Guo
- Center for Advanced Medical Computing and Analysis, Massachusetts General Hospital and Harvard Medical School, 55 Fruit St, White 427, 125 Nashua Street, Suite 660, Boston, MA 02114, United States
| | - Zhixing Qin
- Department of Nuclear Medicine, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
| | - Zhifang Wu
- Department of Nuclear Medicine, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
| | - Huafeng Liu
- College of Optical Science and Engineering, Zhejiang University, 38 Zheda Road, Building 3, Hangzhou 310027, China.
| | - Quanzheng Li
- Center for Advanced Medical Computing and Analysis, Massachusetts General Hospital and Harvard Medical School, 55 Fruit St, White 427, 125 Nashua Street, Suite 660, Boston, MA 02114, United States.
| |
Collapse
|
58
|
Dynamic PET reconstruction using the kernel method with non-local means denoising. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102673] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
59
|
Tsoumpas C, Jørgensen JS, Kolbitsch C, Thielemans K. Synergistic tomographic image reconstruction: part 1. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2021; 379:20200189. [PMID: 33966460 PMCID: PMC8107648 DOI: 10.1098/rsta.2020.0189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
This special issue focuses on synergistic tomographic image reconstruction in a range of contributions in multiple disciplines and various application areas. The topic of image reconstruction covers substantial inverse problems (Mathematics) which are tackled with various methods including statistical approaches (e.g. Bayesian methods, Monte Carlo) and computational approaches (e.g. machine learning, computational modelling, simulations). The issue is separated in two volumes. This volume focuses mainly on algorithms and methods. Some of the articles will demonstrate their utility on real-world challenges, either medical applications (e.g. cardiovascular diseases, proton therapy planning) or applications in material sciences (e.g. material decomposition and characterization). One of the desired outcomes of the special issue is to bring together different scientific communities which do not usually interact as they do not share the same platforms (such as journals and conferences). This article is part of the theme issue 'Synergistic tomographic image reconstruction: part 1'.
Collapse
Affiliation(s)
- Charalampos Tsoumpas
- Biomedical Imaging Science Department, University of Leeds, Leeds, West Yorkshire, UK
- Biomedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
- Invicro, London, UK
| | - Jakob Sauer Jørgensen
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark
- Department of Mathematics, The University of Manchester, Manchester, UK
| | - Christoph Kolbitsch
- Physikalisch-Technische Bundesanstalt, Braunschweig and Berlin, Germany
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
| | - Kris Thielemans
- Institute of Nuclear Medicine, University College London, London, UK
| |
Collapse
|
60
|
Deidda D, Akerele MI, Aykroyd RG, Dweck MR, Ferreira K, Forsythe RO, Heetun W, Newby DE, Syed M, Tsoumpas C. Improved identification of abdominal aortic aneurysm using the Kernelized Expectation Maximization algorithm. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2021; 379:20200201. [PMID: 33966459 PMCID: PMC8107650 DOI: 10.1098/rsta.2020.0201] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Abdominal aortic aneurysm (AAA) monitoring and risk of rupture is currently assumed to be correlated with the aneurysm diameter. Aneurysm growth, however, has been demonstrated to be unpredictable. Using PET to measure uptake of [18F]-NaF in calcified lesions of the abdominal aorta has been shown to be useful for identifying AAA and to predict its growth. The PET low spatial resolution, however, can affect the accuracy of the diagnosis. Advanced edge-preserving reconstruction algorithms can overcome this issue. The kernel method has been demonstrated to provide noise suppression while retaining emission and edge information. Nevertheless, these findings were obtained using simulations, phantoms and a limited amount of patient data. In this study, the authors aim to investigate the usefulness of the anatomically guided kernelized expectation maximization (KEM) and the hybrid KEM (HKEM) methods and to judge the statistical significance of the related improvements. Sixty-one datasets of patients with AAA and 11 from control patients were reconstructed with ordered subsets expectation maximization (OSEM), HKEM and KEM and the analysis was carried out using the target-to-blood-pool ratio, and a series of statistical tests. The results show that all algorithms have similar diagnostic power, but HKEM and KEM can significantly recover uptake of lesions and improve the accuracy of the diagnosis by up to 22% compared to OSEM. The same improvements are likely to be obtained in clinical applications based on the quantification of small lesions, like for example cancer. This article is part of the theme issue 'Synergistic tomographic image reconstruction: part 1'.
Collapse
Affiliation(s)
| | - Mercy I. Akerele
- Biomedical Imaging Science Department, University of Leeds, Leeds, UK
- Department of Radiology, Weill Cornell Medicine, New York, NY, USA
| | | | - Marc R. Dweck
- Edinburgh Imaging Facility, Queen’s Medical Research Institute, Edinburgh, UK
- British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK
| | | | - Rachael O. Forsythe
- Edinburgh Imaging Facility, Queen’s Medical Research Institute, Edinburgh, UK
- British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK
| | | | - David E. Newby
- Edinburgh Imaging Facility, Queen’s Medical Research Institute, Edinburgh, UK
- British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK
| | - Maaz Syed
- Edinburgh Imaging Facility, Queen’s Medical Research Institute, Edinburgh, UK
- British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK
| | | |
Collapse
|
61
|
Arridge SR, Ehrhardt MJ, Thielemans K. (An overview of) Synergistic reconstruction for multimodality/multichannel imaging methods. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2021; 379:20200205. [PMID: 33966461 DOI: 10.1098/rsta.2020.0205] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Imaging is omnipresent in modern society with imaging devices based on a zoo of physical principles, probing a specimen across different wavelengths, energies and time. Recent years have seen a change in the imaging landscape with more and more imaging devices combining that which previously was used separately. Motivated by these hardware developments, an ever increasing set of mathematical ideas is appearing regarding how data from different imaging modalities or channels can be synergistically combined in the image reconstruction process, exploiting structural and/or functional correlations between the multiple images. Here we review these developments, give pointers to important challenges and provide an outlook as to how the field may develop in the forthcoming years. This article is part of the theme issue 'Synergistic tomographic image reconstruction: part 1'.
Collapse
Affiliation(s)
- Simon R Arridge
- Department of Computer Science, University College London, London, UK
| | - Matthias J Ehrhardt
- Department of Mathematical Sciences, University of Bath, Bath, UK
- Institute for Mathematical Innovation, University of Bath, Bath, UK
| | - Kris Thielemans
- Institute of Nuclear Medicine, University College London, London, UK
| |
Collapse
|
62
|
Mao X, Zhao S, Gao D, Hu Z, Zhang N. Direct and indirect parameter imaging methods for dynamic PET. Biomed Phys Eng Express 2021; 7. [PMID: 34087810 DOI: 10.1088/2057-1976/ac086c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Accepted: 06/04/2021] [Indexed: 01/04/2023]
Abstract
The method of reconstructing parametric images from dynamic positron emission tomography (PET) data with the linear Patlak model has been widely used in scientific research and clinical practice. Whether for direct or indirect image reconstruction, researchers have deeply investigated the associated methods and effects. Among the existing methods, the traditional maximum likelihood expectation maximization (MLEM) reconstruction algorithm is fast but produces a substantial amount of noise. If the parameter images obtained by the MLEM algorithm are postfiltered, a large amount of image edge information is lost. Additionally, although the kernel method has a better noise reduction effect, its calculation costs are very high due to the complexity of the algorithm. Therefore, to obtain parametric images with a high signal-to-noise ratio (SNR) and good retention of detailed information, here, we use guided kernel means (GKM) and dynamic PET image information to conduct guided filtering and perform parametric image reconstruction. We apply this method to direct and indirect reconstruction, and through computer simulations, we show that our proposed method has higher identifiability and a greater SNR than conventional direct and indirect reconstruction methods. We also show that our method produces better images with direct than with indirect reconstruction.
Collapse
Affiliation(s)
- Xin Mao
- School of Physics and Microelectronics, Zhengzhou University, Zhengzhou 450001, People's Republic of China.,Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Shujun Zhao
- School of Physics and Microelectronics, Zhengzhou University, Zhengzhou 450001, People's Republic of China
| | - Dongfang Gao
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Zhanli Hu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Na Zhang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| |
Collapse
|
63
|
Cheng Z, Wen J, Huang G, Yan J. Applications of artificial intelligence in nuclear medicine image generation. Quant Imaging Med Surg 2021; 11:2792-2822. [PMID: 34079744 PMCID: PMC8107336 DOI: 10.21037/qims-20-1078] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2020] [Accepted: 02/14/2021] [Indexed: 12/12/2022]
Abstract
Recently, the application of artificial intelligence (AI) in medical imaging (including nuclear medicine imaging) has rapidly developed. Most AI applications in nuclear medicine imaging have focused on the diagnosis, treatment monitoring, and correlation analyses with pathology or specific gene mutation. It can also be used for image generation to shorten the time of image acquisition, reduce the dose of injected tracer, and enhance image quality. This work provides an overview of the application of AI in image generation for single-photon emission computed tomography (SPECT) and positron emission tomography (PET) either without or with anatomical information [CT or magnetic resonance imaging (MRI)]. This review focused on four aspects, including imaging physics, image reconstruction, image postprocessing, and internal dosimetry. AI application in generating attenuation map, estimating scatter events, boosting image quality, and predicting internal dose map is summarized and discussed.
Collapse
Affiliation(s)
- Zhibiao Cheng
- Department of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing, China
| | - Junhai Wen
- Department of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing, China
| | - Gang Huang
- Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai, China
| | - Jianhua Yan
- Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai, China
| |
Collapse
|
64
|
Miranda A, Bertoglio D, Stroobants S, Staelens S, Verhaeghe J. Low activity [ 11C]raclopride kinetic modeling in the mouse brain using the spatiotemporal kernel method. Phys Med Biol 2021; 66. [PMID: 33906176 DOI: 10.1088/1361-6560/abfbf0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Accepted: 04/27/2021] [Indexed: 11/12/2022]
Abstract
Depending on the molar activity of the tracer, the maximal allowable injected activity in mouse brain PET studies can be extremely low in order to avoid receptor saturation. Therefore, a high level of noise can be present in the image. We investigate several dynamic PET reconstruction methods in reduced counts, or equivalently in reduced injected activity, data exemplified in [11C]racloprideBPNDandR1quantification using the simplified reference tissue model (SRTM). We compared independent frame reconstruction (IFR), post-reconstruction HYPR denoising (IFR + HYPR), direct reconstruction using the SRTM model (DIR-SRTM), and the spatial (KERS) and spatiotemporal kernel reconstruction (KERST). Additionally, HYPR denoising of the frames used as features for the calculation of the spatial kernel matrix, was investigated (KERS-HYPR and KERST-HYPR).In vivodata of 11 mice, was used to generate list-mode data for five reduced count levels corresponding to reductions by a factor 4, 8, 12, 16 and 32 (equivalently 2.07, 1.04, 0.691, 0.518, and 0.260 MBq). Correlation of regionalBPNDandR1values (reduced versus full counts reconstructions) was high (r > 0.94) for all methods, with KERS-HYPR and KERST-HYPR reaching the highest correlation (r > 0.96). Among methods with regularization, DIR-SRTM showed the largest variability inBPND(Bland-Altman SD from 3.0% to 12%), while IFR showed it forR1(5.1%-14.6%). KERST and KERST-HYPR were the only methods with Bland-Altman bias and SD below 5% for noise level up to a reduction factor of 16. At the voxel level,BPNDandR1correlation was gradually decreased with increasing noise, with the largest correlation (BPNDr > 0.88,R1r > 0.62) for KERS-HYPR and KERST-HYPR. The spatial and the spatiotemporal kernel methods performed similarly, while using only temporal regularization with direct reconstruction showed more variability. AlthoughR1 values present noise, using the spatiotemporal kernel reconstruction, accurate estimates of binding potential could be obtained with mouse injected activities as low as 0.26-0.518 MBq. This is desirable in order to maintain the tracer kinetics principle in mouse studies.
Collapse
Affiliation(s)
- Alan Miranda
- Molecular Imaging Center Antwerp, University of Antwerp, Universiteitsplein 1, B-2610 Antwerp, Belgium
| | - Daniele Bertoglio
- Molecular Imaging Center Antwerp, University of Antwerp, Universiteitsplein 1, B-2610 Antwerp, Belgium
| | - Sigrid Stroobants
- Molecular Imaging Center Antwerp, University of Antwerp, Universiteitsplein 1, B-2610 Antwerp, Belgium.,University Hospital Antwerp, Wilrijkstraat 10, B-2650 Antwerp, Belgium
| | - Steven Staelens
- Molecular Imaging Center Antwerp, University of Antwerp, Universiteitsplein 1, B-2610 Antwerp, Belgium
| | - Jeroen Verhaeghe
- Molecular Imaging Center Antwerp, University of Antwerp, Universiteitsplein 1, B-2610 Antwerp, Belgium
| |
Collapse
|
65
|
Cheng JCK, Bevington C, Rahmim A, Klyuzhin I, Matthews J, Boellaard R, Sossi V. Dynamic PET image reconstruction utilizing intrinsic data-driven HYPR4D denoising kernel. Med Phys 2021; 48:2230-2244. [PMID: 33533050 DOI: 10.1002/mp.14751] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 10/16/2020] [Accepted: 01/28/2021] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Reconstructed PET images are typically noisy, especially in dynamic imaging where the acquired data are divided into several short temporal frames. High noise in the reconstructed images translates to poor precision/reproducibility of image features. One important role of "denoising" is therefore to improve the precision of image features. However, typical denoising methods achieve noise reduction at the expense of accuracy. In this work, we present a novel four-dimensional (4D) denoised image reconstruction framework, which we validate using 4D simulations, experimental phantom, and clinical patient data, to achieve 4D noise reduction while preserving spatiotemporal patterns/minimizing error introduced by denoising. METHODS Our proposed 4D denoising operator/kernel is based on HighlY constrained backPRojection (HYPR), which is applied either after each update of OSEM reconstruction of dynamic 4D PET data or within the recently proposed kernelized reconstruction framework inspired by kernel methods in machine learning. Our HYPR4D kernel makes use of the spatiotemporal high frequency features extracted from a 4D composite, generated within the reconstruction, to preserve the spatiotemporal patterns and constrain the 4D noise increment of the image estimate. RESULTS Results from simulations, experimental phantom, and patient data showed that the HYPR4D kernel with our proposed 4D composite outperformed other denoising methods, such as the standard OSEM with spatial filter, OSEM with 4D filter, and HYPR kernel method with the conventional 3D composite in conjunction with recently proposed High Temporal Resolution kernel (HYPRC3D-HTR), in terms of 4D noise reduction while preserving the spatiotemporal patterns or 4D resolution within the 4D image estimate. Consequently, the error in outcome measures obtained from the HYPR4D method was less dependent on the region size, contrast, and uniformity/functional patterns within the target structures compared to the other methods. For outcome measures that depend on spatiotemporal tracer uptake patterns such as the nondisplaceable Binding Potential (BPND ), the root mean squared error in regional mean of voxel BPND values was reduced from ~8% (OSEM with spatial or 4D filter) to ~3% using HYPRC3D-HTR and was further reduced to ~2% using our proposed HYPR4D method for relatively small target structures (~10 mm in diameter). At the voxel level, HYPR4D produced two to four times lower mean absolute error in BPND relative to HYPRC3D-HTR. CONCLUSION As compared to conventional methods, our proposed HYPR4D method can produce more robust and accurate image features without requiring any prior information.
Collapse
Affiliation(s)
- Ju-Chieh Kevin Cheng
- Pacific Parkinson's Research Centre, The University of British Columbia, 2215 Wesbrook Mall, Vancouver, BC, V6T 1Z3, Canada.,Department of Physics and Astronomy, The University of British Columbia, 6224 Agricultural Road, Vancouver, BC, V6T 1Z1, Canada
| | - Connor Bevington
- Department of Physics and Astronomy, The University of British Columbia, 6224 Agricultural Road, Vancouver, BC, V6T 1Z1, Canada
| | - Arman Rahmim
- Department of Physics and Astronomy, The University of British Columbia, 6224 Agricultural Road, Vancouver, BC, V6T 1Z1, Canada.,Department of Radiology, University of British Columbia, Vancouver, BC, V5Z 1M9, Canada
| | - Ivan Klyuzhin
- Department of Medicine, Division of Neurology, University of British Columbia, Vancouver, BC, V6T 2B5, Canada
| | - Julian Matthews
- Division of Neuroscience and Experimental Psychology, Wolfson Molecular Imaging Centre, The University of Manchester, Manchester, M20 3LJ, UK
| | - Ronald Boellaard
- Department of Radiology and Nuclear Medicine, VU University Medical Center, De Boelelaan 1117, Amsterdam, 1081 HV, Netherlands.,Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 KC, Groningen, Netherlands
| | - Vesna Sossi
- Department of Physics and Astronomy, The University of British Columbia, 6224 Agricultural Road, Vancouver, BC, V6T 1Z1, Canada
| |
Collapse
|
66
|
Meikle SR, Sossi V, Roncali E, Cherry SR, Banati R, Mankoff D, Jones T, James M, Sutcliffe J, Ouyang J, Petibon Y, Ma C, El Fakhri G, Surti S, Karp JS, Badawi RD, Yamaya T, Akamatsu G, Schramm G, Rezaei A, Nuyts J, Fulton R, Kyme A, Lois C, Sari H, Price J, Boellaard R, Jeraj R, Bailey DL, Eslick E, Willowson KP, Dutta J. Quantitative PET in the 2020s: a roadmap. Phys Med Biol 2021; 66:06RM01. [PMID: 33339012 PMCID: PMC9358699 DOI: 10.1088/1361-6560/abd4f7] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Positron emission tomography (PET) plays an increasingly important role in research and clinical applications, catalysed by remarkable technical advances and a growing appreciation of the need for reliable, sensitive biomarkers of human function in health and disease. Over the last 30 years, a large amount of the physics and engineering effort in PET has been motivated by the dominant clinical application during that period, oncology. This has led to important developments such as PET/CT, whole-body PET, 3D PET, accelerated statistical image reconstruction, and time-of-flight PET. Despite impressive improvements in image quality as a result of these advances, the emphasis on static, semi-quantitative 'hot spot' imaging for oncologic applications has meant that the capability of PET to quantify biologically relevant parameters based on tracer kinetics has not been fully exploited. More recent advances, such as PET/MR and total-body PET, have opened up the ability to address a vast range of new research questions, from which a future expansion of applications and radiotracers appears highly likely. Many of these new applications and tracers will, at least initially, require quantitative analyses that more fully exploit the exquisite sensitivity of PET and the tracer principle on which it is based. It is also expected that they will require more sophisticated quantitative analysis methods than those that are currently available. At the same time, artificial intelligence is revolutionizing data analysis and impacting the relationship between the statistical quality of the acquired data and the information we can extract from the data. In this roadmap, leaders of the key sub-disciplines of the field identify the challenges and opportunities to be addressed over the next ten years that will enable PET to realise its full quantitative potential, initially in research laboratories and, ultimately, in clinical practice.
Collapse
Affiliation(s)
- Steven R Meikle
- Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Australia
- Brain and Mind Centre, The University of Sydney, Australia
| | - Vesna Sossi
- Department of Physics and Astronomy, University of British Columbia, Canada
| | - Emilie Roncali
- Department of Biomedical Engineering, University of California, Davis, United States of America
| | - Simon R Cherry
- Department of Biomedical Engineering, University of California, Davis, United States of America
- Department of Radiology, University of California, Davis, United States of America
| | - Richard Banati
- Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Australia
- Brain and Mind Centre, The University of Sydney, Australia
- Australian Nuclear Science and Technology Organisation, Sydney, Australia
| | - David Mankoff
- Department of Radiology, University of Pennsylvania, United States of America
| | - Terry Jones
- Department of Radiology, University of California, Davis, United States of America
| | - Michelle James
- Department of Radiology, Molecular Imaging Program at Stanford (MIPS), CA, United States of America
- Department of Neurology and Neurological Sciences, Stanford University, CA, United States of America
| | - Julie Sutcliffe
- Department of Biomedical Engineering, University of California, Davis, United States of America
- Department of Internal Medicine, University of California, Davis, CA, United States of America
| | - Jinsong Ouyang
- Gordon Center for Medical Imaging, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Yoann Petibon
- Gordon Center for Medical Imaging, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Chao Ma
- Gordon Center for Medical Imaging, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Georges El Fakhri
- Gordon Center for Medical Imaging, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Suleman Surti
- Department of Radiology, University of Pennsylvania, United States of America
| | - Joel S Karp
- Department of Radiology, University of Pennsylvania, United States of America
| | - Ramsey D Badawi
- Department of Biomedical Engineering, University of California, Davis, United States of America
- Department of Radiology, University of California, Davis, United States of America
| | - Taiga Yamaya
- National Institute of Radiological Sciences (NIRS), National Institutes for Quantum and Radiological Science and Technology (QST), Chiba, Japan
| | - Go Akamatsu
- National Institute of Radiological Sciences (NIRS), National Institutes for Quantum and Radiological Science and Technology (QST), Chiba, Japan
| | - Georg Schramm
- Department of Imaging and Pathology, Nuclear Medicine & Molecular imaging, KU Leuven, Belgium
| | - Ahmadreza Rezaei
- Department of Imaging and Pathology, Nuclear Medicine & Molecular imaging, KU Leuven, Belgium
| | - Johan Nuyts
- Department of Imaging and Pathology, Nuclear Medicine & Molecular imaging, KU Leuven, Belgium
| | - Roger Fulton
- Brain and Mind Centre, The University of Sydney, Australia
- Department of Medical Physics, Westmead Hospital, Sydney, Australia
| | - André Kyme
- Brain and Mind Centre, The University of Sydney, Australia
- School of Biomedical Engineering, Faculty of Engineering and IT, The University of Sydney, Australia
| | - Cristina Lois
- Gordon Center for Medical Imaging, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Hasan Sari
- Department of Radiology, Massachusetts General Hospital & Harvard Medical School, Boston, MA, United States of America
- Athinoula A. Martinos Center, Massachusetts General Hospital & Harvard Medical School, Boston, MA, United States of America
| | - Julie Price
- Department of Radiology, Massachusetts General Hospital & Harvard Medical School, Boston, MA, United States of America
- Athinoula A. Martinos Center, Massachusetts General Hospital & Harvard Medical School, Boston, MA, United States of America
| | - Ronald Boellaard
- Radiology and Nuclear Medicine, Cancer Center Amsterdam, Amsterdam University Medical Center, location VUMC, Netherlands
| | - Robert Jeraj
- Departments of Medical Physics, Human Oncology and Radiology, University of Wisconsin, United States of America
- Faculty of Mathematics and Physics, University of Ljubljana, Slovenia
| | - Dale L Bailey
- Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Australia
- Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia
- Faculty of Science, The University of Sydney, Australia
| | - Enid Eslick
- Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia
| | - Kathy P Willowson
- Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia
- Faculty of Science, The University of Sydney, Australia
| | - Joyita Dutta
- Department of Electrical and Computer Engineering, University of Massachusetts Lowell, United States of America
| |
Collapse
|
67
|
da Costa-Luis CO, Reader AJ. Micro-Networks for Robust MR-Guided Low Count PET Imaging. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021; 5:202-212. [PMID: 33681546 PMCID: PMC7931458 DOI: 10.1109/trpms.2020.2986414] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Revised: 12/30/2019] [Accepted: 02/08/2020] [Indexed: 01/18/2023]
Abstract
Noise suppression is particularly important in low count positron emission tomography (PET) imaging. Post-smoothing (PS) and regularization methods which aim to reduce noise also tend to reduce resolution and introduce bias. Alternatively, anatomical information from another modality such as magnetic resonance (MR) imaging can be used to improve image quality. Convolutional neural networks (CNNs) are particularly well suited to such joint image processing, but usually require large amounts of training data and have mostly been applied outside the field of medical imaging or focus on classification and segmentation, leaving PET image quality improvement relatively understudied. This article proposes the use of a relatively low-complexity CNN (micro-net) as a post-reconstruction MR-guided image processing step to reduce noise and reconstruction artefacts while also improving resolution in low count PET scans. The CNN is designed to be fully 3-D, robust to very limited amounts of training data, and to accept multiple inputs (including competitive denoising methods). Application of the proposed CNN on simulated low (30 M) count data (trained to produce standard (300 M) count reconstructions) results in a 36% lower normalized root mean squared error (NRMSE, calculated over ten realizations against the ground truth) compared to maximum-likelihood expectation maximization (MLEM) used in clinical practice. In contrast, a decrease of only 25% in NRMSE is obtained when an optimized (using knowledge of the ground truth) PS is performed. A 26% NRMSE decrease is obtained with both RM and optimized PS. Similar improvement is also observed for low count real patient datasets. Overfitting to training data is demonstrated to occur as the network size is increased. In an extreme case, a U-net (which produces better predictions for training data) is shown to completely fail on test data due to overfitting to this case of very limited training data. Meanwhile, the resultant images from the proposed CNN (which has low training data requirements) have lower noise, reduced ringing, and partial volume effects, as well as sharper edges and improved resolution compared to conventional MLEM.
Collapse
Affiliation(s)
- Casper O. da Costa-Luis
- Department of Biomedical EngineeringSchool of Biomedical Engineering and Imaging Sciences, St. Thomas’ HospitalKing’s College LondonLondonSE1 7EHU.K.
| | - Andrew J. Reader
- Department of Biomedical EngineeringSchool of Biomedical Engineering and Imaging Sciences, St. Thomas’ HospitalKing’s College LondonLondonSE1 7EHU.K.
| |
Collapse
|
68
|
Marquis H, Deidda D, Gillman A, Willowson KP, Gholami Y, Hioki T, Eslick E, Thielemans K, Bailey DL. Theranostic SPECT reconstruction for improved resolution: application to radionuclide therapy dosimetry. EJNMMI Phys 2021; 8:16. [PMID: 33598750 PMCID: PMC7889770 DOI: 10.1186/s40658-021-00362-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 02/02/2021] [Indexed: 12/20/2022] Open
Abstract
Background SPECT-derived dose estimates in tissues of diameter less than 3× system resolution are subject to significant losses due to the limited spatial resolution of the gamma camera. Incorporating resolution modelling (RM) into the SPECT reconstruction has been proposed as a possible solution; however, the images produced are prone to noise amplification and Gibbs artefacts. We propose a novel approach to SPECT reconstruction in a theranostic setting, which we term SPECTRE (single photon emission computed theranostic reconstruction); using a diagnostic PET image, with its superior resolution, to guide the SPECT reconstruction of the therapeutic equivalent. This report demonstrates a proof in principle of this approach. Methods We have employed the hybrid kernelised expectation maximisation (HKEM) algorithm implemented in STIR, with the aim of producing SPECT images with PET-equivalent resolution. We demonstrate its application in both a dual 68Ga/177Lu IEC phantom study and a clinical example using 64Cu/67Cu. Results SPECTRE is shown to produce images comparable in accuracy and recovery to PET with minimal introduction of artefacts and amplification of noise. Conclusion The SPECTRE approach to image reconstruction shows improved quantitative accuracy with a reduction in noise amplification. SPECTRE shows great promise as a method of improving SPECT radioactivity concentrations, directly leading to more accurate dosimetry estimates in small structures and target lesions. Further investigation and optimisation of the algorithm parameters is needed before this reconstruction method can be utilised in a clinical setting.
Collapse
Affiliation(s)
- H Marquis
- Sydney Vital Translational Cancer Research Centre, Sydney, Australia.,Institute of Medical Physics, University of Sydney, Sydney, Australia
| | - D Deidda
- National Physical Laboratory, Teddington, UK
| | - A Gillman
- Australian e-Health Research Centre, CSIRO, Brisbane, Australia
| | - K P Willowson
- Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia
| | - Y Gholami
- Sydney Vital Translational Cancer Research Centre, Sydney, Australia.,Institute of Medical Physics, University of Sydney, Sydney, Australia.,Faculty of Medicine and Health, University of Sydney, Sydney, Australia
| | - T Hioki
- Institute of Medical Physics, University of Sydney, Sydney, Australia
| | - E Eslick
- Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia
| | - K Thielemans
- Institute of Nuclear Medicine, University College London, London, UK
| | - D L Bailey
- Sydney Vital Translational Cancer Research Centre, Sydney, Australia. .,Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia. .,Faculty of Medicine and Health, University of Sydney, Sydney, Australia.
| |
Collapse
|
69
|
Gao J, Liu Q, Zhou C, Zhang W, Wan Q, Hu C, Gu Z, Liang D, Liu X, Yang Y, Zheng H, Hu Z, Zhang N. An improved patch-based regularization method for PET image reconstruction. Quant Imaging Med Surg 2021; 11:556-570. [PMID: 33532256 DOI: 10.21037/qims-20-19] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Background Statistical reconstruction methods based on penalized maximum likelihood (PML) are being increasingly used in positron emission tomography (PET) imaging to reduce noise and improve image quality. Wang and Qi proposed a patch-based edge-preserving penalties algorithm that can be implemented in three simple steps: a maximum-likelihood expectation-maximization (MLEM) image update, an image smoothing step, and a pixel-by-pixel image fusion step. The pixel-by-pixel image fusion step, which fuses the MLEM updated image and the smoothed image, involves a trade-off between preserving the fine structural features of an image and suppressing noise. Particularly when reconstructing images from low-count data, this step cannot preserve fine structural features in detail. To better preserve these features and accelerate the algorithm convergence, we proposed to improve the patch-based regularization reconstruction method. Methods Our improved method involved adding a total variation (TV) regularization step following the MLEM image update in the patch-based algorithm. A feature refinement (FR) step was then used to extract the lost fine structural features from the residual image between the TV regularized image and the fused image based on patch regularization. These structural features would then be added back to the fused image. With the addition of these steps, each iteration of the image should gain more structural information. A brain phantom simulation experiment and a mouse study were conducted to evaluate our proposed improved method. Brain phantom simulation with added noise were used to determine the feasibility of the proposed algorithm and its acceleration of convergence. Data obtained from the mouse study were divided into event count sets to validate the performance of the proposed algorithm when reconstructing images from low-count data. Five criteria were used for quantitative evaluation: signal-to-noise ratio (SNR), covariance (COV), contrast recovery coefficient (CRC), regional relative bias, and relative variance. Results The bias and variance of the phantom brain image reconstructed using the patch-based method were 0.421 and 5.035, respectively, and this process took 83.637 seconds. The bias and variance of the image reconstructed by the proposed improved method, however, were 0.396 and 4.568, respectively, and this process took 41.851 seconds. This demonstrates that the proposed algorithm accelerated the reconstruction convergence. The CRC of the phantom brain image reconstructed using the patch-based method was iterated 20 times and reached 0.284, compared with the proposed method, which reached 0.446. When using a count of 5,000 K data obtained from the mouse study, both the patch-based method and the proposed method reconstructed images similar to the ground truth image. The intensity of the ground truth image was 88.3, and it was located in the 102nd row and the 116th column. However, when the count was reduced to below 40 K, and the patch-based method was used, image quality was significantly reduced. This effect was not observed when the proposed method was used. When a count of 40 K was used, the image intensity was 58.79 when iterated 100 times by the patch-based method, and it was located in the 102nd row and the 116th column, while the intensity when iterated 50 times by the proposed method was 63.83. This suggests that the proposed method improves image reconstruction from low-count data. Conclusions This improved method of PET image reconstruction could potentially improve the quality of PET images faster than other methods and also produce better reconstructions from low-count data.
Collapse
Affiliation(s)
- Juan Gao
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen, China.,Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen, China.,School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Qiegen Liu
- Department of Electronic Information Engineering, Nanchang University, Nanchang, China
| | - Chao Zhou
- Department of Nuclear Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Weiguang Zhang
- Department of Nuclear Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Qian Wan
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen, China.,Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen, China
| | - Chenxi Hu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zheng Gu
- Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, China
| | - Dong Liang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen, China.,Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen, China
| | - Xin Liu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen, China.,Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen, China
| | - Yongfeng Yang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen, China.,Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen, China
| | - Hairong Zheng
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen, China.,Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen, China
| | - Zhanli Hu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen, China.,Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen, China
| | - Na Zhang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Chinese Academy of Sciences Key Laboratory of Health Informatics, Shenzhen, China.,Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen, China
| |
Collapse
|
70
|
Li S, Wang G. Neural MLAA for PET-enabled Dual-Energy CT Imaging. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2021; 11595:115951G. [PMID: 36883104 PMCID: PMC9986115 DOI: 10.1117/12.2582317] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
The PET-enabled dual-energy CT method allows dual-energy CT imaging on PET/CT scanners without the need for a second x-ray CT scan. A 511 keV γ-ray attenuation image can be reconstructed from time-of-flight PET emission data using the maximum-likelihood attenuation and activity (MLAA) algorithm. However, the attenuation image reconstructed by standard MLAA is commonly noisy. To suppress noise, we propose a neural-network approach for MLAA reconstruction. The PET attenuation image is described as a function of kernelized neural networks with the flexibility of incorporating the available x-ray CT image as anatomical prior. By applying optimization transfer, the complex optimization problem of the proposed neural MLAA reconstruction is solved by a modularized iterative algorithm with each iteration decomposed into three steps: PET activity image update, attenuation image update, and neural-network learning using a weighed mean squared-error loss. The optimization algorithm is guaranteed to monotonically increase the data likelihood. The results from computer simulations demonstrated the neural MLAA algorithm can achieve a significant improvement on the γ-ray CT image quality as compared to other algorithms.
Collapse
Affiliation(s)
- Siqi Li
- Department of Radiology, University of California Davis Medical Center, Sacramento, CA 95817, United States
| | - Guobao Wang
- Department of Radiology, University of California Davis Medical Center, Sacramento, CA 95817, United States
| |
Collapse
|
71
|
Hashimoto F, Ohba H, Ote K, Kakimoto A, Tsukada H, Ouchi Y. 4D deep image prior: dynamic PET image denoising using an unsupervised four-dimensional branch convolutional neural network. Phys Med Biol 2021; 66:015006. [PMID: 33227725 DOI: 10.1088/1361-6560/abcd1a] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Although convolutional neural networks (CNNs) demonstrate the superior performance in denoising positron emission tomography (PET) images, a supervised training of the CNN requires a pair of large, high-quality PET image datasets. As an unsupervised learning method, a deep image prior (DIP) has recently been proposed; it can perform denoising with only the target image. In this study, we propose an innovative procedure for the DIP approach with a four-dimensional (4D) branch CNN architecture in end-to-end training to denoise dynamic PET images. Our proposed 4D CNN architecture can be applied to end-to-end dynamic PET image denoising by introducing a feature extractor and a reconstruction branch for each time frame of the dynamic PET image. In the proposed DIP method, it is not necessary to prepare high-quality and large patient-related PET images. Instead, a subject's own static PET image is used as additional information, dynamic PET images are treated as training labels, and denoised dynamic PET images are obtained from the CNN outputs. Both simulation with [18F]fluoro-2-deoxy-D-glucose (FDG) and preclinical data with [18F]FDG and [11C]raclopride were used to evaluate the proposed framework. The results showed that our 4D DIP framework quantitatively and qualitatively outperformed 3D DIP and other unsupervised denoising methods. The proposed 4D DIP framework thus provides a promising procedure for dynamic PET image denoising.
Collapse
Affiliation(s)
- Fumio Hashimoto
- Central Research Laboratory, Hamamatsu Photonics K. K., 5000 Hirakuchi, Hamakita-ku, Hamamatsu 434-8601, Japan
| | | | | | | | | | | |
Collapse
|
72
|
Abstract
Total-body PET image reconstruction follows a similar procedure to the image reconstruction process for standard whole-body PET scanners. One unique aspect of total-body imaging is simultaneous coverage of the entire human body, which makes it convenient to perform total-body dynamic PET scans. Therefore, four-dimensional dynamic PET reconstruction and parametric imaging are of great interest in total-body imaging. This article covers some basics of PET image reconstruction and then focuses on three- and four-dimensional PET reconstruction for total-body imaging. Methods for image formation from raw measurements in total-body PET are described. Challenges and opportunities in total-body PET image reconstruction are discussed.
Collapse
Affiliation(s)
- Jinyi Qi
- Department of Biomedical Engineering, University of California, One Shields Avenue, Davis, CA 95616, USA.
| | - Samuel Matej
- Department of Radiology, University of Pennsylvania, 3620 Hamilton Walk, John Morgan Building, Room 156A, Philadelphia, PA 19104-6061, USA
| | - Guobao Wang
- Department of Radiology, University of California Davis Medical Center, Lawrence J. Ellison Ambulatory Care Center Building, Suite 3100, 4860 Y Street, Sacramento, CA 95817, USA
| | - Xuezhu Zhang
- Department of Biomedical Engineering, University of California, One Shields Avenue, Davis, CA 95616, USA
| |
Collapse
|
73
|
Reader AJ, Corda G, Mehranian A, Costa-Luis CD, Ellis S, Schnabel JA. Deep Learning for PET Image Reconstruction. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021. [DOI: 10.1109/trpms.2020.3014786] [Citation(s) in RCA: 65] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
74
|
Huang Y, Wan Q, Chen Z, Hu Z, Cheng G, Qi Y. An iterative reconstruction method for sparse-projection data for low-dose CT. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2021; 29:797-812. [PMID: 34366362 DOI: 10.3233/xst-210906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Reducing X-ray radiation is beneficial for reducing the risk of cancer in patients. There are two main approaches for achieving this goal namely, one is to reduce the X-ray current, and another is to apply sparse-view protocols to do image scanning and projections. However, these techniques usually lead to degradation of the reconstructed image quality, resulting in excessive noise and severe edge artifacts, which seriously affect the diagnosis result. In order to overcome such limitation, this study proposes and tests an algorithm based on guided kernel filtering. The algorithm combines the characteristics of anisotropic edges between adjacent image voxels, expresses the relevant weights with an exponential function, and adjusts the weights adaptively through local gray gradients to better preserve the image structure while suppressing noise information. Experiments show that the proposed method can effectively suppress noise and preserve the image structure. Comparing with similar algorithms, the proposed algorithm greatly improves the peak signal-to-noise ratio (PSNR), structural similarity (SSIM), and root mean square error (RMSE) of the reconstructed image. The proposed algorithm has the best effect in quantitative analysis, which verifies the effectiveness of the proposed method and good image reconstruction performance. Overall, this study demonstrates that the proposed method can reduce the number of projections required for repeated CT scans and has potential for medical applications in reducing radiation doses.
Collapse
Affiliation(s)
- Ying Huang
- School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing, China
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Qian Wan
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
- Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Beijing, China
| | - Zixiang Chen
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Zhanli Hu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Guanxun Cheng
- Department of Radiology, Peking University Shenzhen Hospital, Shenzhen, China
| | - Yulong Qi
- Department of Radiology, Peking University Shenzhen Hospital, Shenzhen, China
| |
Collapse
|
75
|
Bailey DL, Sabanathan D, Aslani A, Campbell DH, Walsh BJ, Lengkeek NA. RetroSPECT: Gallium-67 as a Long-Lived Imaging Agent for Theranostics. ASIA OCEANIA JOURNAL OF NUCLEAR MEDICINE & BIOLOGY 2021; 9:1-8. [PMID: 33392343 PMCID: PMC7701228 DOI: 10.22038/aojnmb.2020.51714.1355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 10/28/2020] [Accepted: 10/31/2020] [Indexed: 11/06/2022]
Abstract
A limitation to the wider introduction of personalised dosimetry in theranostics is the relative paucity of imaging radionuclides with suitable physical and chemical properties to be paired with a long-lived therapeutic partner. As most of the beta-emitting therapeutic radionuclides emit gamma radiation as well they could potentially be used as the imaging radionuclide as well as the therapeutic radionuclide. However, the downsides are that the beta radiation will deliver a significant radiation dose as part of the treatment planning procedure, and the gamma radiation branching ratio is often quite low. Gallium-67 has been in use in nuclear medicine for over 50 years. However, the tremendous interest in gallium imaging in theranostics in recent times has focused on the PET radionuclide gallium-68. In this article it is suggested that the longer-lived gallium-67, which has desirable characteristics for imaging with the gamma camera and a suitably long half-life to match biological timescales for drug uptake and turnover, has been overlooked, in particular, for treatment planning with radionuclide therapy. Gallium-67 could also allow non-PET facilities to participate in theranostic imaging prior to treatment or for monitoring response after therapy. Gallium-67 could play a niche role in the future development of personalised medicine with theranostics.
Collapse
Affiliation(s)
- Dale L. Bailey
- Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia
- Faculty of Medicine & Health, University of Sydney, Sydney, Australia
| | | | - Alireza Aslani
- Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia
- Faculty of Medicine & Health, University of Sydney, Sydney, Australia
| | | | | | - Nigel A. Lengkeek
- Biosciences, Australian Nuclear Science & Technology Organisation (ANSTO), Sydney, Australia
| |
Collapse
|
76
|
Wang G. PET-enabled dual-energy CT: image reconstruction and a proof-of-concept computer simulation study. Phys Med Biol 2020; 65:245028. [PMID: 33120376 DOI: 10.1088/1361-6560/abc5ca] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Standard dual-energy computed tomography (CT) uses two different x-ray energies to obtain energy-dependent tissue attenuation information to allow quantitative material decomposition. The combined use of dual-energy CT and positron emission tomography (PET) may provide a more comprehensive characterization of disease states in cancer and other diseases. However, the integration of dual-energy CT with PET is not trivial, either requiring costly hardware upgrades or increasing radiation exposure. This paper proposes a different dual-energy CT imaging method that is enabled by PET. Instead of using a second x-ray CT scan with a different energy, this method exploits time-of-flight PET image reconstruction via the maximum likelihood attenuation and activity (MLAA) algorithm to obtain a 511 keV gamma-ray attenuation image from PET emission data. The high-energy gamma-ray attenuation image is then combined with the low-energy x-ray CT of PET/CT to provide a pair of dual-energy CT images. A major challenge with the standard MLAA reconstruction is the high noise present in the reconstructed 511 keV attenuation map, which would not compromise the PET activity reconstruction too much but may significantly affect the performance of the gamma-ray attenuation image for material decomposition. To overcome the problem, we further propose a kernel MLAA algorithm to exploit the prior information from the available x-ray CT image. We conducted a computer simulation to test the concept and algorithm for the task of material decomposition. The simulation results demonstrate that this PET-enabled dual-energy CT method is promising for quantitative material decomposition. The proposed method can be readily implemented on time-of-flight PET/CT scanners to enable simultaneous PET and dual-energy CT imaging.
Collapse
Affiliation(s)
- Guobao Wang
- Department of Radiology, University of California, Davis, CA, United States of America
| |
Collapse
|
77
|
Xie N, Gong K, Guo N, Qin Z, Wu Z, Liu H, Li Q. Penalized-likelihood PET Image Reconstruction Using 3D Structural Convolutional Sparse Coding. IEEE Trans Biomed Eng 2020; 69:4-14. [PMID: 33284746 DOI: 10.1109/tbme.2020.3042907] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Positron emission tomography (PET) is widely used for clinical diagnosis. As PET suffers from low resolution and high noise, numerous efforts try to incorporate anatomical priors into PET image reconstruction, especially with the development of hybrid PET/CT and PET/MRI systems. In this work, we proposed a cube-based 3D structural convolutional sparse coding (CSC) concept for penalized-likelihood PET image reconstruction, named 3D PET-CSC. The proposed 3D PET-CSC takes advantage of the convolutional operation and manages to incorporate anatomical priors without the need of registration or supervised training. As 3D PET-CSC codes the whole 3D PET image, instead of patches, it alleviates the staircase artifacts commonly presented in traditional patch-based sparse coding methods. Compared with traditional coding methods in Fourier domain, the proposed method extends the 3D CSC to a straightforward approach based on the pursuit of localized cubes. Moreover, we developed the residual-image and order-subset mechanisms to further reduce the computational cost and accelerate the convergence for the proposed 3D PET-CSC method. Experiments based on computer simulations and clinical datasets demonstrate the superiority of 3D PET-CSC compared with other reference methods.
Collapse
|
78
|
Zeng T, Gao J, Gao D, Kuang Z, Sang Z, Wang X, Hu L, Chen Q, Chu X, Liang D, Liu X, Yang Y, Zheng H, Hu Z. A GPU-accelerated fully 3D OSEM image reconstruction for a high-resolution small animal PET scanner using dual-ended readout detectors. ACTA ACUST UNITED AC 2020; 65:245007. [DOI: 10.1088/1361-6560/aba6f9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
79
|
Huang HM. Kernel-based curve-fitting method with spatial regularization for generation of parametric images in dynamic PET. Phys Med Biol 2020; 65:225006. [PMID: 33200750 DOI: 10.1088/1361-6560/abb1d8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Due to high levels of noise in pixel-wise time-activity curves, the indirect method that generates kinetic parametric images from dynamic positron emission tomography (PET) images often results in poor parametric image quality. We have demonstrated that the quality of parametric images can be improved by denoising dynamic PET images, using gradient-free curve-fitting and applying a kernel-based post-filtering to parametric images. However, many gradient-free curve-fitting methods are time-consuming. Moreover, some parameter estimates (e.g. k2 and k3) have large variability. To provide high-quality PET parametric images with low computational cost, we propose a curve-fitting method that incorporates the kernel-based denoising method and the highly constrained backprojection technique into the Levenberg-Marquardt (LM) algorithm. We conducted a simulation study to evaluate the performance of the proposed curve-fitting method. Dynamic PET images were reconstructed using the expectation-maximization (EM) algorithm and were denoised before parameter estimation. Compared to the LM algorithm with and without the kernel-based post-filtering, the proposed method achieved superior performance, offering a decrease in both bias and coefficient of variation (CV) on all parametric images. Overall, the proposed method exhibited lower bias and slightly higher CV than the gradient-free pattern search method with the kernel-based post-filtering (PatS-K). Moreover, the computation time of the proposed method was about 18 times lower than that of the PatS-K method. Finally, we show that the proposed method can further improve the quality of parametric images when dynamic PET images are reconstructed using the kernel-based EM algorithm.
Collapse
Affiliation(s)
- Hsuan-Ming Huang
- Institute of Medical Device and Imaging, College of Medicine, National Taiwan University, No.1, Sec. 1, Jen Ai Rd., Zhongzheng Dist., Taipei City 100, Taiwan
| |
Collapse
|
80
|
Hu J, Panin V, Smith AM, Spottiswoode B, Shah V, CA von Gall C, Baker M, Howe W, Kehren F, Casey M, Bendriem B. Design and Implementation of Automated Clinical Whole Body Parametric PET With Continuous Bed Motion. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2020. [DOI: 10.1109/trpms.2020.2994316] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
81
|
Wang G, Rahmim A, Gunn RN. PET Parametric Imaging: Past, Present, and Future. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2020; 4:663-675. [PMID: 33763624 PMCID: PMC7983029 DOI: 10.1109/trpms.2020.3025086] [Citation(s) in RCA: 56] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Positron emission tomography (PET) is actively used in a diverse range of applications in oncology, cardiology, and neurology. The use of PET in the clinical setting focuses on static (single time frame) imaging at a specific time-point post radiotracer injection and is typically considered as semi-quantitative; e.g. standardized uptake value (SUV) measures. In contrast, dynamic PET imaging requires increased acquisition times but has the advantage that it measures the full spatiotemporal distribution of a radiotracer and, in combination with tracer kinetic modeling, enables the generation of multiparametric images that more directly quantify underlying biological parameters of interest, such as blood flow, glucose metabolism, and receptor binding. Parametric images have the potential for improved detection and for more accurate and earlier therapeutic response assessment. Parametric imaging with dynamic PET has witnessed extensive research in the past four decades. In this paper, we provide an overview of past and present activities and discuss emerging opportunities in the field of parametric imaging for the future.
Collapse
Affiliation(s)
- Guobao Wang
- Department of Radiology, University of California Davis Health, Sacramento, CA 95817, USA
| | - Arman Rahmim
- University of British Columbia, Vancouver, BC, Canada
| | | |
Collapse
|
82
|
Zuo Y, Badawi RD, Foster CC, Smith T, López JE, Wang G. Multiparametric Cardiac 18F-FDG PET in Humans: Kinetic Model Selection and Identifiability Analysis. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2020; 4:759-767. [PMID: 33778234 DOI: 10.1109/trpms.2020.3031274] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Cardiac 18F-FDG PET has been used in clinics to assess myocardial glucose metabolism. Its ability for imaging myocardial glucose transport, however, has rarely been exploited in clinics. Using the dynamic FDG-PET scans of ten patients with coronary artery disease, we investigate in this paper appropriate dynamic scan and kinetic modeling protocols for efficient quantification of myocardial glucose transport. Three kinetic models and the effect of scan duration were evaluated by using statistical fit quality, assessing the impact on kinetic quantification, and analyzing the practical identifiability. The results show that the kinetic model selection depends on the scan duration. The reversible two-tissue model was needed for a one-hour dynamic scan. The irreversible two-tissue model was optimal for a scan duration of around 10-15 minutes. If the scan duration was shortened to 2-3 minutes, a one-tissue model was the most appropriate. For global quantification of myocardial glucose transport, we demonstrated that an early dynamic scan with a duration of 10-15 minutes and irreversible kinetic modeling was comparable to the full one-hour scan with reversible kinetic modeling. Myocardial glucose transport quantification provides an additional physiological parameter on top of the existing assessment of glucose metabolism and has the potential to enable single tracer multiparametric imaging in the myocardium.
Collapse
Affiliation(s)
- Yang Zuo
- Department of Radiology, University of California Davis Medical Center, Sacramento, CA 9817
| | - Ramsey D Badawi
- Department of Radiology and Department of Biomedical Engineering, University of California Davis Medical Center, Sacramento, CA 9817
| | - Cameron C Foster
- Department of Radiology, University of California Davis Medical Center, Sacramento, CA 9817
| | - Thomas Smith
- Department of Internal Medicine, University of California Davis Medical Center, Sacramento, CA 9817
| | - Javier E López
- Department of Internal Medicine, University of California Davis Medical Center, Sacramento, CA 9817
| | - Guobao Wang
- Department of Radiology, University of California Davis Medical Center, Sacramento, CA 9817
| |
Collapse
|
83
|
|
84
|
Bal A, Banerjee M, Chaki R, Sharma P. An efficient method for PET image denoising by combining multi-scale transform and non-local means. MULTIMEDIA TOOLS AND APPLICATIONS 2020; 79:29087-29120. [DOI: 10.1007/s11042-020-08936-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Revised: 02/14/2020] [Accepted: 04/13/2020] [Indexed: 04/01/2025]
|
85
|
Arabi H, Zaidi H. Applications of artificial intelligence and deep learning in molecular imaging and radiotherapy. Eur J Hybrid Imaging 2020; 4:17. [PMID: 34191161 PMCID: PMC8218135 DOI: 10.1186/s41824-020-00086-8] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Accepted: 08/10/2020] [Indexed: 12/22/2022] Open
Abstract
This brief review summarizes the major applications of artificial intelligence (AI), in particular deep learning approaches, in molecular imaging and radiation therapy research. To this end, the applications of artificial intelligence in five generic fields of molecular imaging and radiation therapy, including PET instrumentation design, PET image reconstruction quantification and segmentation, image denoising (low-dose imaging), radiation dosimetry and computer-aided diagnosis, and outcome prediction are discussed. This review sets out to cover briefly the fundamental concepts of AI and deep learning followed by a presentation of seminal achievements and the challenges facing their adoption in clinical setting.
Collapse
Affiliation(s)
- Hossein Arabi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva 4, Switzerland
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211, Geneva 4, Switzerland.
- Geneva University Neurocenter, Geneva University, CH-1205, Geneva, Switzerland.
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, 9700, Groningen, RB, Netherlands.
- Department of Nuclear Medicine, University of Southern Denmark, 500, Odense, Denmark.
| |
Collapse
|
86
|
Cui J, Qin Z, Chen S, Chen Y, Liu H. Structure and Tracer Kinetics-Driven Dynamic PET Reconstruction. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2020. [DOI: 10.1109/trpms.2019.2947860] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
87
|
Xie Z, Baikejiang R, Li T, Zhang X, Gong K, Zhang M, Qi W, Asma E, Qi J. Generative adversarial network based regularized image reconstruction for PET. Phys Med Biol 2020; 65:125016. [PMID: 32357352 PMCID: PMC7413644 DOI: 10.1088/1361-6560/ab8f72] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Positron emission tomography (PET) is an ill-posed inverse problem and suffers high noise due to limited number of detected events. Prior information can be used to improve the quality of reconstructed PET images. Deep neural networks have also been applied to regularized image reconstruction. One method is to use a pretrained denoising neural network to represent the PET image and to perform a constrained maximum likelihood estimation. In this work, we propose to use a generative adversarial network (GAN) to further improve the network performance. We also modify the objective function to include a data-matching term on the network input. Experimental studies using computer-based Monte Carlo simulations and real patient datasets demonstrate that the proposed method leads to noticeable improvements over the kernel-based and U-net-based regularization methods in terms of lesion contrast recovery versus background noise trade-offs.
Collapse
Affiliation(s)
- Zhaoheng Xie
- Department of Biomedical Engineering University of California Davis CA United States of America
| | | | | | | | | | | | | | | | | |
Collapse
|
88
|
Reader AJ, Ellis S. Bootstrap-Optimised Regularised Image Reconstruction for Emission Tomography. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:2163-2175. [PMID: 31944935 PMCID: PMC7273977 DOI: 10.1109/tmi.2019.2956878] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Revised: 11/22/2019] [Accepted: 11/24/2019] [Indexed: 06/10/2023]
Abstract
In emission tomography, iterative image reconstruction from noisy measured data usually results in noisy images, and so regularisation is often used to compensate for noise. However, in practice, an appropriate, automatic and precise specification of the strength of regularisation for image reconstruction from a given noisy measured dataset remains unresolved. Existing approaches are either empirical approximations with no guarantee of generalisation, or else are computationally intensive cross-validation methods requiring full reconstructions for a limited set of preselected regularisation strengths. In contrast, we propose a novel methodology embedded within iterative image reconstruction, using one or more bootstrapped replicates of the measured data for precise optimisation of the regularisation. The approach uses a conventional unregularised iterative update of a current image estimate from the noisy measured data, and then also uses the bootstrap replicate to obtain a bootstrap update of the current image estimate. The method then seeks the regularisation hyperparameters which, when applied to the bootstrap update of the image, lead to a best fit of the regularised bootstrap update to the conventional measured data update. This corresponds to estimating the degree of regularisation needed in order to map the noisy update to a model of the mean of an ensemble of noisy updates. For a given regularised objective function (e.g. penalised likelihood), no hyperparameter selection or tuning is required. The method is demonstrated for positron emission tomography (PET) data at different noise levels, and delivers near-optimal reconstructions (in terms of reconstruction error) without any knowledge of the ground truth, nor any form of training data.
Collapse
Affiliation(s)
- Andrew J. Reader
- School of Biomedical Engineering and Imaging SciencesKing’s College London, King’s Health Partners, St Thomas’ HospitalLondonSE1 7EHU.K.
| | - Sam Ellis
- School of Biomedical Engineering and Imaging SciencesKing’s College London, King’s Health Partners, St Thomas’ HospitalLondonSE1 7EHU.K.
| |
Collapse
|
89
|
Zhang X, Cherry SR, Xie Z, Shi H, Badawi RD, Qi J. Subsecond total-body imaging using ultrasensitive positron emission tomography. Proc Natl Acad Sci U S A 2020; 117:2265-2267. [PMID: 31964808 PMCID: PMC7007535 DOI: 10.1073/pnas.1917379117] [Citation(s) in RCA: 101] [Impact Index Per Article: 20.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
A 194-cm-long total-body positron emission tomography/computed tomography (PET/CT) scanner (uEXPLORER), has been constructed to offer a transformative platform for human radiotracer imaging in clinical research and healthcare. Its total-body coverage and exceptional sensitivity provide opportunities for innovative studies of physiology, biochemistry, and pharmacology. The objective of this study is to develop a method to perform ultrahigh (100 ms) temporal resolution dynamic PET imaging by combining advanced dynamic image reconstruction paradigms with the uEXPLORER scanner. We aim to capture the fast dynamics of initial radiotracer distribution, as well as cardiac motion, in the human body. The results show that we can visualize radiotracer transport in the body on timescales of 100 ms and obtain motion-frozen images with superior image quality compared to conventional methods. The proposed method has applications in studying fast tracer dynamics, such as blood flow and the dynamic response to neural modulation, as well as performing real-time motion tracking (e.g., cardiac and respiratory motion, and gross body motion) without any external monitoring device (e.g., electrocardiogram, breathing belt, or optical trackers).
Collapse
Affiliation(s)
- Xuezhu Zhang
- Department of Biomedical Engineering, University of California, Davis, CA 95616;
| | - Simon R Cherry
- Department of Biomedical Engineering, University of California, Davis, CA 95616
- Department of Radiology, University of California Davis Medical Center, Sacramento, CA 95817
| | - Zhaoheng Xie
- Department of Biomedical Engineering, University of California, Davis, CA 95616
| | - Hongcheng Shi
- Department of Nuclear Medicine, Zhongshan Hospital Fudan University, 200032 Shanghai, China
| | - Ramsey D Badawi
- Department of Biomedical Engineering, University of California, Davis, CA 95616
- Department of Radiology, University of California Davis Medical Center, Sacramento, CA 95817
| | - Jinyi Qi
- Department of Biomedical Engineering, University of California, Davis, CA 95616;
| |
Collapse
|
90
|
Wadhwa P, Thielemans K, Efthimiou N, Wangerin K, Keat N, Emond E, Deller T, Bertolli O, Deidda D, Delso G, Tohme M, Jansen F, Gunn RN, Hallett W, Tsoumpas C. PET image reconstruction using physical and mathematical modelling for time of flight PET-MR scanners in the STIR library. Methods 2020; 185:110-119. [PMID: 32006678 DOI: 10.1016/j.ymeth.2020.01.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 11/15/2019] [Accepted: 01/14/2020] [Indexed: 10/25/2022] Open
Abstract
This work demonstrates how computational and physical modelling of the positron emission tomography (PET) image acquisition process for a state-of-the-art integrated PET and magnetic resonance imaging (PET-MR) system can produce images comparable to the manufacturer. The GE SIGNA PET/MR scanner is manufactured by General Electric and has time-of-flight (TOF) capabilities of about 390 ps. All software development took place in the Software for Tomographic Image Reconstruction (STIR: http://stir.sf.net) library, which is a widely used open source software to reconstruct data as exported from emission tomography scanners. The new software developments will be integrated into STIR, providing the opportunity for researchers worldwide to establish and expand their image reconstruction methods. Furthermore, this work is of particular significance as it provides the first validation of TOF PET image reconstruction for real scanner datasets using the STIR library. This paper presents the methodology, analysis, and critical issues encountered in implementing an independent reconstruction software package. Acquired PET data were processed via several appropriate algorithms which are necessary to produce an accurate and precise quantitative image. This included mathematical, physical and anatomical modelling of the patient and simulation of various aspects of the acquisition. These included modelling of random coincidences using 'singles' rates per crystals, detector efficiencies and geometric effects. Attenuation effects were calculated by using the STIR's attenuation correction model. Modelling all these effects within the system matrix allowed the reconstruction of PET images which demonstrates the metabolic uptake of the administered radiopharmaceutical. These implementations were validated using measured phantom and clinical datasets. The developments are tested using the ordered subset expectation maximisation (OSEM) and the more recently proposed kernelised expectation maximisation (KEM) algorithm which incorporates anatomical information from MR images into PET reconstruction.
Collapse
Affiliation(s)
- Palak Wadhwa
- Biomedical Imaging Science Department, School of Medicine, University of Leeds, UK; Invicro, London, UK.
| | - Kris Thielemans
- Institute of Nuclear Medicine, University College London, UK
| | - Nikos Efthimiou
- PET Research Centre, Faculty of Health Sciences, University of Hull, UK
| | | | | | - Elise Emond
- Institute of Nuclear Medicine, University College London, UK
| | | | | | - Daniel Deidda
- Biomedical Imaging Science Department, School of Medicine, University of Leeds, UK; National Physical Laboratory, Teddington, UK
| | | | | | | | | | | | - Charalampos Tsoumpas
- Biomedical Imaging Science Department, School of Medicine, University of Leeds, UK; Invicro, London, UK.
| |
Collapse
|
91
|
Ashouri Z, Hunter CR, Spencer BA, Wang G, Dansereau RM, deKemp RA. Kernel-Based Reconstruction of C-11-Hydroxyephedrine Cardiac PET Images of the Sympathetic Nervous System. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:832-835. [PMID: 31946024 DOI: 10.1109/embc.2019.8856752] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Image reconstruction for positron emission tomography (PET) can be challenging and the resulting image typically has high noise. The kernel-based reconstruction method [1], incorporates prior anatomic information in the reconstruction algorithm to reduce noise while preserving resolution. Prior information is incorporated in the reconstruction algorithm by means of spatial kernels originally used in machine learning. In this paper, the kernel-based method is used to reconstruct PET images of sympathetic innervation in the heart. The resulting images are compared with standard Ordered Subset Expectation Maximization (OSEM) reconstructed images qualitatively and quantitatively using data from 6 human subjects. The kernel-based method demonstrated superior SNR with preserved contrast and accuracy compared to OSEM.
Collapse
|
92
|
Gong K, Berg E, Cherry SR, Qi J. Machine Learning in PET: from Photon Detection to Quantitative Image Reconstruction. PROCEEDINGS OF THE IEEE. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS 2020; 108:51-68. [PMID: 38045770 PMCID: PMC10691821 DOI: 10.1109/jproc.2019.2936809] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/05/2023]
Abstract
Machine learning has found unique applications in nuclear medicine from photon detection to quantitative image reconstruction. While there have been impressive strides in detector development for time-of-flight positron emission tomography, most detectors still make use of simple signal processing methods to extract the time and position information from the detector signals. Now with the availability of fast waveform digitizers, machine learning techniques have been applied to estimate the position and arrival time of high-energy photons. In quantitative image reconstruction, machine learning has been used to estimate various corrections factors, including scattered events and attenuation images, as well as to reduce statistical noise in reconstructed images. Here machine learning either provides a faster alternative to an existing time-consuming computation, such as in the case of scatter estimation, or creates a data-driven approach to map an implicitly defined function, such as in the case of estimating the attenuation map for PET/MR scans. In this article, we will review the abovementioned applications of machine learning in nuclear medicine.
Collapse
Affiliation(s)
- Kuang Gong
- Department of Biomedical Engineering, University of California, Davis, CA, USA and is now with Massachusetts General Hospital, Boston, MA, USA
| | - Eric Berg
- Department of Biomedical Engineering, University of California, Davis, CA, USA
| | - Simon R. Cherry
- Department of Biomedical Engineering and Department of Radiology, University of California, Davis, CA, USA
| | - Jinyi Qi
- Department of Biomedical Engineering, University of California, Davis, CA, USA
| |
Collapse
|
93
|
Chen Z, Zhang Q, Zhou C, Zhang M, Yang Y, Liu X, Zheng H, Liang D, Hu Z. Low-dose CT reconstruction method based on prior information of normal-dose image. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2020; 28:1091-1111. [PMID: 33044223 DOI: 10.3233/xst-200716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
BACKGROUND Radiation risk from computed tomography (CT) is always an issue for patients, especially those in clinical conditions in which repeated CT scanning is required. For patients undergoing repeated CT scanning, a low-dose protocol, such as sparse scanning, is often used, and consequently, an advanced reconstruction algorithm is also needed. OBJECTIVE To develop a novel algorithm used for sparse-view CT reconstruction associated with the prior image. METHODS A low-dose CT reconstruction method based on prior information of normal-dose image (PI-NDI) involving a transformed model for attenuation coefficients of the object to be reconstructed and prior information application in the forward-projection process was used to reconstruct CT images from sparse-view projection data. A digital extended cardiac-torso (XCAT) ventral phantom and a diagnostic head phantom were employed to evaluate the performance of the proposed PI-NDI method. The root-mean-square error (RMSE), peak signal-to-noise ratio (PSNR) and mean percent absolute error (MPAE) of the reconstructed images were measured for quantitative evaluation of the proposed PI-NDI method. RESULTS The reconstructed images with sparse-view projection data via the proposed PI-NDI method have higher quality by visual inspection than that via the compared methods. In terms of quantitative evaluations, the RMSE measured on the images reconstructed by the PI-NDI method with sparse projection data is comparable to that by MLEM-TV, PWLS-TV and PWLS-PICCS with fully sampled projection data. When the projection data are very sparse, images reconstructed by the PI-NDI method have higher PSNR values and lower MPAE values than those from the compared algorithms. CONCLUSIONS This study presents a new low-dose CT reconstruction method based on prior information of normal-dose image (PI-NDI) for sparse-view CT image reconstruction. The experimental results validate that the new method has superior performance over other state-of-art methods.
Collapse
Affiliation(s)
- Zixiang Chen
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Qiyang Zhang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Chao Zhou
- Department of Nuclear Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Mengxi Zhang
- Department of Biomedical Engineering, University of California, Davis, CA, USA
| | - Yongfeng Yang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xin Liu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Hairong Zheng
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Dong Liang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Zhanli Hu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| |
Collapse
|
94
|
3D Tensor Based Nonlocal Low Rank Approximation in Dynamic PET Reconstruction. SENSORS 2019; 19:s19235299. [PMID: 31805743 PMCID: PMC6928938 DOI: 10.3390/s19235299] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 11/24/2019] [Accepted: 11/26/2019] [Indexed: 11/17/2022]
Abstract
Reconstructing images from multi-view projections is a crucial task both in the computer vision community and in the medical imaging community, and dynamic positron emission tomography (PET) is no exception. Unfortunately, image quality is inevitably degraded by the limitations of photon emissions and the trade-off between temporal and spatial resolution. In this paper, we develop a novel tensor based nonlocal low-rank framework for dynamic PET reconstruction. Spatial structures are effectively enhanced not only by nonlocal and sparse features, but momentarily by tensor-formed low-rank approximations in the temporal realm. Moreover, the total variation is well regularized as a complementation for denoising. These regularizations are efficiently combined into a Poisson PET model and jointly solved by distributed optimization. The experiments demonstrated in this paper validate the excellent performance of the proposed method in dynamic PET.
Collapse
|
95
|
Bland J, Mehranian A, Belzunce MA, Ellis S, da Costa‐Luis C, McGinnity CJ, Hammers A, Reader AJ. Intercomparison of MR-informed PET image reconstruction methods. Med Phys 2019; 46:5055-5074. [PMID: 31494961 PMCID: PMC6899618 DOI: 10.1002/mp.13812] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2019] [Revised: 08/23/2019] [Accepted: 08/23/2019] [Indexed: 12/28/2022] Open
Abstract
PURPOSE Numerous image reconstruction methodologies for positron emission tomography (PET) have been developed that incorporate magnetic resonance (MR) imaging structural information, producing reconstructed images with improved suppression of noise and reduced partial volume effects. However, the influence of MR structural information also increases the possibility of suppression or bias of structures present only in the PET data (PET-unique regions). To address this, further developments for MR-informed methods have been proposed, for example, through inclusion of the current reconstructed PET image, alongside the MR image, in the iterative reconstruction process. In this present work, a number of kernel and maximum a posteriori (MAP) methodologies are compared, with the aim of identifying methods that enable a favorable trade-off between the suppression of noise and the retention of unique features present in the PET data. METHODS The reconstruction methods investigated were: the MR-informed conventional and spatially compact kernel methods, referred to as KEM and KEM largest value sparsification (LVS) respectively; the MR-informed Bowsher and Gaussian MR-guided MAP methods; and the PET-MR-informed hybrid kernel and anato-functional MAP methods. The trade-off between improving the reconstruction of the whole brain region and the PET-unique regions was investigated for all methods in comparison with postsmoothed maximum likelihood expectation maximization (MLEM), evaluated in terms of structural similarity index (SSIM), normalized root mean square error (NRMSE), bias, and standard deviation. Both simulated BrainWeb (10 noise realizations) and real [18 F] fluorodeoxyglucose (FDG) three-dimensional datasets were used. The real [18 F]FDG dataset was augmented with simulated tumors to allow comparison of the reconstruction methodologies for the case of known regions of PET-MR discrepancy and evaluated at full counts (100%) and at a reduced (10%) count level. RESULTS For the high-count simulated and real data studies, the anato-functional MAP method performed better than the other methods under investigation (MR-informed, PET-MR-informed and postsmoothed MLEM), in terms of achieving the best trade-off for the reconstruction of the whole brain and PET-unique regions, assessed in terms of the SSIM, NRMSE, and bias vs standard deviation. The inclusion of PET information in the anato-functional MAP method enables the reconstruction of PET-unique regions to attain similarly low levels of bias as unsmoothed MLEM, while moderately improving the whole brain image quality for low levels of regularization. However, for low count simulated datasets the anato-functional MAP method performs poorly, due to the inclusion of noisy PET information in the regularization term. For the low counts simulated dataset, KEM LVS and to a lesser extent, HKEM performed better than the other methods under investigation in terms of achieving the best trade-off for the reconstruction of the whole brain and PET-unique regions, assessed in terms of the SSIM, NRMSE, and bias vs standard deviation. CONCLUSION For the reconstruction of noisy data, multiple MR-informed methods produce favorable whole brain vs PET-unique region trade-off in terms of the image quality metrics of SSIM and NRMSE, comfortably outperforming the whole image denoising of postsmoothed MLEM.
Collapse
Affiliation(s)
- James Bland
- School of Biomedical Engineering and Imaging SciencesKing's College LondonSt Thomas' HospitalLondonSE1 7EHUK
| | - Abolfazl Mehranian
- School of Biomedical Engineering and Imaging SciencesKing's College LondonSt Thomas' HospitalLondonSE1 7EHUK
| | - Martin A. Belzunce
- School of Biomedical Engineering and Imaging SciencesKing's College LondonSt Thomas' HospitalLondonSE1 7EHUK
| | - Sam Ellis
- School of Biomedical Engineering and Imaging SciencesKing's College LondonSt Thomas' HospitalLondonSE1 7EHUK
| | - Casper da Costa‐Luis
- School of Biomedical Engineering and Imaging SciencesKing's College LondonSt Thomas' HospitalLondonSE1 7EHUK
| | - Colm J. McGinnity
- King's College London & Guy's and St Thomas' PET CentreSt Thomas' HospitalLondonSE1 7EHUK
| | - Alexander Hammers
- King's College London & Guy's and St Thomas' PET CentreSt Thomas' HospitalLondonSE1 7EHUK
| | - Andrew J. Reader
- School of Biomedical Engineering and Imaging SciencesKing's College LondonSt Thomas' HospitalLondonSE1 7EHUK
| |
Collapse
|
96
|
Zhu Y, Zhu X. MRI-Driven PET Image Optimization for Neurological Applications. Front Neurosci 2019; 13:782. [PMID: 31417346 PMCID: PMC6684790 DOI: 10.3389/fnins.2019.00782] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2018] [Accepted: 07/12/2019] [Indexed: 12/12/2022] Open
Abstract
Positron emission tomography (PET) and magnetic resonance imaging (MRI) are established imaging modalities for the study of neurological disorders, such as epilepsy, dementia, psychiatric disorders and so on. Since these two available modalities vary in imaging principle and physical performance, each technique has its own advantages and disadvantages over the other. To acquire the mutual complementary information and reinforce each other, there is a need for the fusion of PET and MRI. This combined dual-modality (either sequential or simultaneous) could generate preferable soft tissue contrast of brain tissue, flexible acquisition parameters, and minimized exposure to radiation. The most unique superiority of PET/MRI is mainly manifested in MRI-based improvement for the inherent limitations of PET, such as motion artifacts, partial volume effect (PVE) and invasive procedure in quantitative analysis. Head motion during scanning significantly deteriorates the effective resolution of PET image, especially for the dynamic scan with lengthy time. Hybrid PET/MRI device can offer motion correction (MC) for PET data through MRI information acquired simultaneously. Regarding the PVE associated with limited spatial resolution, the process and reconstruction of PET data can be further optimized by using acquired MRI either sequentially or simultaneously. The quantitative analysis of dynamic PET data mainly relies upon an invasive arterial blood sampling procedure to acquire arterial input function (AIF). An image-derived input function (IDIF) method without the need of arterial cannulization, can serve as a potential alternative estimation of AIF. Compared with using PET data only, combining anatomical or functional information from MRI for improving the accuracy in IDIF approach has been demonstrated. Yet, due to the interference and inherent disparity between the two modalities, these methods for optimizing PET image based on MRI still have many technical challenges. This review discussed upon the most recent progress, current challenges and future directions of MRI-driven PET data optimization for neurological applications, with either sequential or simultaneous acquisition approach.
Collapse
Affiliation(s)
- Yuankai Zhu
- Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiaohua Zhu
- Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
97
|
Zhang X, Xie Z, Berg E, Judenhofer MS, Liu W, Xu T, Ding Y, Lv Y, Dong Y, Deng Z, Tang S, Shi H, Hu P, Chen S, Bao J, Li H, Zhou J, Wang G, Cherry SR, Badawi RD, Qi J. Total-Body Dynamic Reconstruction and Parametric Imaging on the uEXPLORER. J Nucl Med 2019; 61:285-291. [DOI: 10.2967/jnumed.119.230565] [Citation(s) in RCA: 85] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 07/06/2019] [Indexed: 01/02/2023] Open
|
98
|
Gong K, Catana C, Qi J, Li Q. PET Image Reconstruction Using Deep Image Prior. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:1655-1665. [PMID: 30575530 PMCID: PMC6584077 DOI: 10.1109/tmi.2018.2888491] [Citation(s) in RCA: 121] [Impact Index Per Article: 20.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Recently, deep neural networks have been widely and successfully applied in computer vision tasks and have attracted growing interest in medical imaging. One barrier for the application of deep neural networks to medical imaging is the need for large amounts of prior training pairs, which is not always feasible in clinical practice. This is especially true for medical image reconstruction problems, where raw data are needed. Inspired by the deep image prior framework, in this paper, we proposed a personalized network training method where no prior training pairs are needed, but only the patient's own prior information. The network is updated during the iterative reconstruction process using the patient-specific prior information and measured data. We formulated the maximum-likelihood estimation as a constrained optimization problem and solved it using the alternating direction method of multipliers algorithm. Magnetic resonance imaging guided positron emission tomography reconstruction was employed as an example to demonstrate the effectiveness of the proposed framework. Quantification results based on simulation and real data show that the proposed reconstruction framework can outperform Gaussian post-smoothing and anatomically guided reconstructions using the kernel method or the neural-network penalty.
Collapse
|
99
|
Ramon AJ, Yang Y, Pretorius PH, Johnson KL, King MA, Wernick MN. Personalized Models for Injected Activity Levels in SPECT Myocardial Perfusion Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:1466-1476. [PMID: 30530358 PMCID: PMC6582653 DOI: 10.1109/tmi.2018.2885319] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
We propose a patient-specific ("personalized") approach for tailoring the injected activities to individual patients in order to achieve dose reduction in SPECT-myocardial perfusion imaging (MPI). First, we develop a strategy to determine the minimum dose levels required for each patient in a large set of clinical acquisitions (857 subjects) such that the reconstructed images are sufficiently similar to that obtained at conventional clinical dose. We then apply machine learning models to predict the required dose levels on an individual basis based on a set of patient attributes which include body measurements and various clinical variables. We demonstrate the personalized dose models for two commonly used reconstruction methods in clinical SPECT-MPI: 1) conventional filtered backprojection (FBP) with post-filtering and 2) ordered-subsets expectation-maximization (OS-EM) with corrections for attenuation, scatter and resolution, and evaluate their performance in perfusion-defect detection by using the clinical Quantitative Perfusion SPECT software package. The results indicate that the achieved dose reduction can vary greatly among individuals from their conventional clinical dose and that the personalized dose models can achieve further reduction on average compared with a global (non-patient specific) dose reduction approach. In particular, the average personalized dose level can be reduced to 58% and 54% of the full clinical dose, respectively, for FBP and OS-EM reconstruction, while without deteriorating the accuracy in perfusion-defect detection. Furthermore, with the average personalized dose further reduced to only 16% of full dose, OS-EM can still achieve a detection accuracy level comparable to that of FBP with full dose.
Collapse
Affiliation(s)
| | | | - P. Hendrik Pretorius
- Department of Radiology, Division of Nuclear Medicine, University of Massachusetts Medical School, Worcester, MA 01655 USA
| | - Karen L. Johnson
- Department of Radiology, Division of Nuclear Medicine, University of Massachusetts Medical School, Worcester, MA 01655 USA
| | - Michael A. King
- Department of Radiology, Division of Nuclear Medicine, University of Massachusetts Medical School, Worcester, MA 01655 USA
| | | |
Collapse
|
100
|
Abstract
PET images often suffer poor signal-to-noise ratio (SNR). Our objective is to improve the SNR of PET images using a deep neural network (DNN) model and MRI images without requiring any higher SNR PET images in training. Our proposed DNN model consists of three modified U-Nets (3U-net). The PET training input data and targets were reconstructed using filtered-backprojection (FBP) and maximum likelihood expectation maximization (MLEM), respectively. FBP reconstruction was used because of its computational efficiency so that the trained network not only removes noise, but also accelerates image reconstruction. Digital brain phantoms downloaded from BrainWeb were used to evaluate the proposed method. Poisson noise was added into sinogram data to simulate a 6 min brain PET scan. Attenuation effect was included and corrected before the image reconstruction. Extra Poisson noise was introduced to the training inputs to improve the network denoising capability. Three independent experiments were conducted to examine the reproducibility. A lesion was inserted into testing data to evaluate the impact of mismatched MRI information using the contrast-to-noise ratio (CNR). The negative impact on noise reduction was also studied when miscoregistration between PET and MRI images occurs. Compared with 1U-net trained with only PET images, training with PET/MRI decreased the mean squared error (MSE) by 31.3% and 34.0% for 1U-net and 3U-net, respectively. The MSE reduction is equivalent to an increase in the count level by 2.5 folds and 2.9 folds for 1U-net and 3U-net, respectively. Compared with the MLEM images, the lesion CNR was improved 2.7 folds and 1.4 folds for 1U-net and 3U-net, respectively. The results show that the proposed method could improve the PET SNR without having higher SNR PET images.
Collapse
Affiliation(s)
- Chih-Chieh Liu
- Department of Biomedical Engineering, University of California, Davis, CA, United States of America
| | | |
Collapse
|