1
|
Lim S, Park YJ, Lee SJ, An YS, Yoon JK. Clinical Feasibility of Deep Learning-Based Attenuation Correction Models for Tl-201 Myocardial Perfusion SPECT. Clin Nucl Med 2024; 49:397-403. [PMID: 38409758 DOI: 10.1097/rlu.0000000000005129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
PURPOSE We aimed to develop deep learning (DL)-based attenuation correction models for Tl-201 myocardial perfusion SPECT (MPS) images and evaluate their clinical feasibility. PATIENTS AND METHODS We conducted a retrospective study of patients with suspected or known coronary artery disease. We proposed a DL-based image-to-image translation technique to transform non-attenuation-corrected images into CT-based attenuation-corrected (CT AC ) images. The model was trained using a modified U-Net with structural similarity index (SSIM) loss and mean squared error (MSE) loss and compared with other models. Segment-wise analysis using a polar map and visual assessment for the generated attenuation-corrected (GEN AC ) images were also performed to evaluate clinical feasibility. RESULTS This study comprised 657 men and 328 women (age, 65 ± 11 years). Among the various models, the modified U-Net achieved the highest performance with an average mean absolute error of 0.003, an SSIM of 0.990, and a peak signal-to-noise ratio of 33.658. The performance of the model was not different between the stress and rest datasets. In the segment-wise analysis, the myocardial perfusion of the inferior wall was significantly higher in GEN AC images than in the non-attenuation-corrected images in both the rest and stress test sets ( P < 0.05). In the visual assessment of patients with diaphragmatic attenuation, scores of 4 (similar to CT AC images) or 5 (indistinguishable from CT AC images) were assigned to most GEN AC images (65/68). CONCLUSIONS Our clinically feasible DL-based attenuation correction models can replace the CT-based method in Tl-201 MPS, and it would be useful in case SPECT/CT is unavailable for MPS.
Collapse
Affiliation(s)
- Sungjoo Lim
- From the Department of Biomedical Systems Informatics, Yonsei University, Seoul
| | - Yong-Jin Park
- Department of Nuclear Medicine and Molecular Imaging, Ajou University School of Medicine, Suwon, South Korea
| | - Su Jin Lee
- Department of Nuclear Medicine and Molecular Imaging, Ajou University School of Medicine, Suwon, South Korea
| | - Young-Sil An
- Department of Nuclear Medicine and Molecular Imaging, Ajou University School of Medicine, Suwon, South Korea
| | - Joon-Kee Yoon
- Department of Nuclear Medicine and Molecular Imaging, Ajou University School of Medicine, Suwon, South Korea
| |
Collapse
|
2
|
Sung C, Han S, Yoon S, Han SA, Kang DY, Kim DH, Park DW, Song JM, Lee JS, Ryu JS, Moon DH. Diagnostic Performance of Perfusion-Only SPECT/CT for Chronic Thromboembolic Pulmonary Hypertension in Comparison With Ventilation-Perfusion Planar, SPECT, and SPECT/CT Imaging. Clin Nucl Med 2024; 49:427-433. [PMID: 38467577 DOI: 10.1097/rlu.0000000000005142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/13/2024]
Abstract
PURPOSE The aim of this study was to assess the diagnostic performance of perfusion-only SPECT/CT (Q SPECT/CT) in comparison with that of ventilation/perfusion planar scintigraphy (V/Q planar), perfusion SPECT with ventilation scan (V/Q SPECT), and perfusion SPECT/CT with ventilation scan (V/Q SPECT/CT) in chronic thromboembolic pulmonary hypertension (CTEPH). PATIENTS AND METHODS Patients with pulmonary hypertension who underwent ventilation-perfusion planar and SPECT/CT were retrospectively recruited. Two nuclear medicine physicians interpreted V/Q planar, V/Q SPECT, V/Q SPECT/CT, and Q SPECT/CT according to the European Association of Nuclear Medicine criteria. The diagnostic accuracy of these modalities for CTEPH was compared using a composite reference standard of pulmonary angiography, imaging test, cardiorespiratory assessment, and follow-up. RESULTS A total of 192 patients were enrolled, including 85 with CTEPH. The sensitivity of Q SPECT/CT was 98.8%, which similar to that of V/Q planar (97.6%), V/Q SPECT (96.5%), or V/Q SPECT/CT (100.0%). In contrast, Q SPECT/CT exhibited significantly lower specificity (73.8%) compared with V/Q planar (86.9%, P = 0.001), V/Q SPECT (87.9%, P < 0.001), and V/Q SPECT/CT (88.8%, P < 0.001). The significantly lower specificity of Q SPECT/CT, compared with the 3 others, was observed in the subgroup aged ≥50 years ( P < 0.001 for all), but not in those <50 years. CONCLUSIONS Q SPECT/CT exhibited lower specificity compared with V/Q planar, V/Q SPECT, and V/Q SPECT/CT in diagnosing CTEPH. It might underscore the essential role of a ventilation scan in patients with PH, even with the introduction of SPECT/CT.
Collapse
|
3
|
Hesse M, Dupont F, Mourad N, Babczenko P, Beaurin G, Xhema D, Bonaccorsi-Riani E, Jamar F, Lhommel R. Kidney dynamic SPECT acquisition on a CZT swiveling-detector ring camera: an in vivo pilot study. BMC Med Imaging 2024; 24:94. [PMID: 38649862 PMCID: PMC11036633 DOI: 10.1186/s12880-024-01271-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 04/08/2024] [Indexed: 04/25/2024] Open
Abstract
BACKGROUND Large field of view CZT SPECT cameras with a ring geometry are available for some years now. Thanks to their good sensitivity and high temporal resolution, general dynamic SPECT imaging may be performed more easily, without resorting to dedicated systems. To evaluate the dynamic SPECT imaging by such cameras, we have performed an in vivo pilot study to analyze the kidney function of a pig and compare the results to standard dynamic planar imaging by a conventional gamma camera. METHODS A 7-week-old (12 kg) female Landrace pig was injected with [99mTc]Tc-MAG3 and a 30 min dynamic SPECT acquisition of the kidneys was performed on a CZT ring camera. A fast SPECT/CT was acquired with the same camera immediately after the dynamic SPECT, without moving the pig, and used for attenuation correction and drawing regions of interest. The next day the same pig underwent a dynamic planar imaging of the kidneys by a conventional 2-head gamma camera. The dynamic SPECT acquisition was reconstructed using a MLEM algorithm with up to 20 iterations, with and without attenuation correction. Time-activity curves of the total counts of each kidney were extracted from 2D and 3D dynamic images. An adapted 2-compartment model was derived to fit the data points and extract physiological parameters. Comparison of these parameters was performed between the different reconstructions and acquisitions. RESULTS Time-activity curves were nicely fitted with the 2-compartment model taking into account the anesthesia and bladder filling. Kidney physiological parameters were found in agreement with literature values. Good agreement of these parameters was obtained for the right kidney between dynamic SPECT and planar imaging. Regional analysis of the kidneys can be performed in the case of the dynamic SPECT imaging and provided good agreement with the whole kidney results. CONCLUSIONS Dynamic SPECT imaging is feasible with CZT swiveling-detector ring cameras and provides results in agreement with dynamic planar imaging by conventional gamma cameras. Regional analysis of organs uptake and clearance becomes possible. Further studies are required regarding the optimization of acquisition and reconstruction parameters to improve image quality and enable absolute quantification.
Collapse
Affiliation(s)
- Michel Hesse
- Nuclear Medicine Department, Cliniques Universitaires Saint-Luc, 10 Avenue Hippocrate, 1200, Brussels, Belgium.
| | - Florian Dupont
- Nuclear Medicine Department, Cliniques Universitaires Saint-Luc, 10 Avenue Hippocrate, 1200, Brussels, Belgium
| | - Nizar Mourad
- Pôle de Chirurgie Expérimentale et Transplantation- CHEX, Cliniques Universitaires Saint-Luc, Brussels, Belgium
| | - Pavel Babczenko
- Pôle de Chirurgie Expérimentale et Transplantation- CHEX, Cliniques Universitaires Saint-Luc, Brussels, Belgium
| | - Gwen Beaurin
- Pôle de Chirurgie Expérimentale et Transplantation- CHEX, Cliniques Universitaires Saint-Luc, Brussels, Belgium
| | - Daela Xhema
- Pôle de Chirurgie Expérimentale et Transplantation- CHEX, Cliniques Universitaires Saint-Luc, Brussels, Belgium
| | - Eliano Bonaccorsi-Riani
- Pôle de Chirurgie Expérimentale et Transplantation- CHEX, Cliniques Universitaires Saint-Luc, Brussels, Belgium
| | - François Jamar
- Nuclear Medicine Department, Cliniques Universitaires Saint-Luc, 10 Avenue Hippocrate, 1200, Brussels, Belgium
| | - Renaud Lhommel
- Nuclear Medicine Department, Cliniques Universitaires Saint-Luc, 10 Avenue Hippocrate, 1200, Brussels, Belgium
| |
Collapse
|
4
|
Sarrut D, Etxebeste A, Létang JM. A photon source model for alpha-emitter radionuclides. Phys Med Biol 2024; 69:095009. [PMID: 38537308 DOI: 10.1088/1361-6560/ad3881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 03/27/2024] [Indexed: 04/18/2024]
Abstract
Objective.A Monte Carlo virtual source model named PHID (photon from Ion decay) that generates photons emitted in the complex decay chain process of alpha-emitter radionuclides is proposed, typically for use during the simulation of SPECT image acquisition.Approach.Given an alpha-emitter radionuclide, the PHID model extracts from Geant4 databases the photon emission lines from all decaying daughters for both isometric transition and atomic relaxation processes. According to a given time range, abundances and activities in the decay chain are considered thanks to the Bateman equations, taking into account the decay rates and the initial abundances.Main results.PHID is evaluated by comparison with analog Monte Carlo simulation. It generates photons with the correct energy and temporal distribution, avoiding the costly simulation of the complete decay chain thus decreasing the computation time. The exact time gain depends on the simulation setup. As an example, it is 30× faster for simulating 1 MBq of225Ac in water for 1 section Moreover, for225Ac, PHID was also compared to a simplified source model with the two main photon emission lines (218 and 440 keV). PHID shows that 2 times more particles are simulated and 60% more counts are detected in the images.Significance.PHID can simulate any alpha-emitter radionuclide available in the Geant4 database. As a limitation, photons emitted from Bremsstrahlung are ignored, but they represent only 0.7% of the photons above 30 keV and are not significant for SPECT imaging. PHID is open-source, available in GATE 10, and eases the investigation of imaging photon emission from alpha emitters.
Collapse
Affiliation(s)
- D Sarrut
- CREATIS; CNRS UMR5220; Inserm U1044; INSA-Lyon; Université Lyon 1; Centre Léon Bérard, France
| | - A Etxebeste
- CREATIS; CNRS UMR5220; Inserm U1044; INSA-Lyon; Université Lyon 1; Centre Léon Bérard, France
| | - J M Létang
- CREATIS; CNRS UMR5220; Inserm U1044; INSA-Lyon; Université Lyon 1; Centre Léon Bérard, France
| |
Collapse
|
5
|
Bohrmann L, Poulie CBM, Rodríguez-Rodríguez C, Karagiozov S, Saatchi K, Herth MM, Häfeli UO. Development of a 99mTc-labeled tetrazine for pretargeted SPECT imaging using an alendronic acid-based bone targeting model. PLoS One 2024; 19:e0300466. [PMID: 38626058 PMCID: PMC11020896 DOI: 10.1371/journal.pone.0300466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Accepted: 02/27/2024] [Indexed: 04/18/2024] Open
Abstract
Pretargeting, which is the separation of target accumulation and the administration of a secondary imaging agent into two sequential steps, offers the potential to improve image contrast and reduce radiation burden for nuclear imaging. In recent years, the tetrazine ligation has emerged as a promising approach to facilitate covalent pretargeted imaging due to its unprecedented kinetics and bioorthogonality. Pretargeted bone imaging with TCO-modified alendronic acid (Aln-TCO) is an attractive model that allows the evaluation of tetrazines in healthy animals without the need for complex disease models or targeting regimens. Recent structure-activity relationship studies of tetrazines evaluated important parameters for the design of potent tetrazine-radiotracers for pretargeted imaging. However, limited information is available for 99mTc-labeled tetrazines. In this study, four tetrazines intended for labeling with fac-[99mTc(OH2)3 (CO)3]+ were synthesized and evaluated using an Aln-TCO mouse model. 3,6-bis(2-pyridyl)-1,2,4,5-Tz without additional linker showed higher pretargeted bone uptake and less background activity compared to the same scaffold with a PEG8 linker or 3-phenyl-1,2,4,5-Tz-based compounds. Additionally, improved bone/blood ratios were observed in pretargeted animals compared to animals receiving directly labeled Aln-TCO. The results of this study implicate 3,6-bis(2-pyridyl)-1,2,4,5-Tz as a promising scaffold for potential 99mTc-labeled tetrazines.
Collapse
Affiliation(s)
- Lennart Bohrmann
- Faculty of Pharmaceutical Sciences, University of British Columbia, Vancouver, BC, Canada
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken, Copenhagen, Denmark
| | - Christian B. M. Poulie
- Department of Drug Design and Pharmacology, Faculty of Health and Medicinal Sciences, University of Copenhagen, Universitetsparken, Copenhagen, Denmark
| | | | - Stoyan Karagiozov
- Faculty of Pharmaceutical Sciences, University of British Columbia, Vancouver, BC, Canada
| | - Katayoun Saatchi
- Faculty of Pharmaceutical Sciences, University of British Columbia, Vancouver, BC, Canada
| | - Matthias M. Herth
- Department of Drug Design and Pharmacology, Faculty of Health and Medicinal Sciences, University of Copenhagen, Universitetsparken, Copenhagen, Denmark
- Department of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, Blegdamsvej, Copenhagen, Denmark
| | - Urs O. Häfeli
- Faculty of Pharmaceutical Sciences, University of British Columbia, Vancouver, BC, Canada
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken, Copenhagen, Denmark
| |
Collapse
|
6
|
Han D, Hyun MC, Miller RJH, Gransar H, Slomka PJ, Dey D, Hayes SW, Friedman JD, Thomson LEJ, Berman DS, Rozanski A. 10-year experience of utilizing a stress-first SPECT myocardial perfusion imaging. Int J Cardiol 2024; 401:131863. [PMID: 38365012 DOI: 10.1016/j.ijcard.2024.131863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 01/24/2024] [Accepted: 02/12/2024] [Indexed: 02/18/2024]
Abstract
BACKGROUND Despite its potential benefits, the utilization of stress-only protocol in clinical practice has been limited. We report utilizing stress-first single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). METHODS We assessed 12,472 patients who were referred for SPECT-MPI between 2013 and 2020. The temporal changes in frequency of stress-only imaging were assessed according to risk factors, mode of stress, prior coronary artery disease (CAD) history, left ventricular function, and symptom status. The clinical endpoint was all-cause mortality. RESULTS In our lab, stress/rest SPECT-MPI in place of rest/stress SPECT-MPI was first introduced in November 2011 and was performed more commonly than rest/stress imaging after 2013. Stress-only SPECT-MPI scanning has been performed in 30-34% of our SPECT-MPI studies since 2013 (i.e.. 31.7% in 2013 and 33.6% in 2020). During the study period, we routinely used two-position imaging (additional prone or upright imaging) to reduce attenuation and motion artifact and introduced SPECT/CT scanner in 2018. The rate of stress-only study remained consistent before and after implementing the SPECT/CT scanner. The frequency of stress-only imaging was 43% among patients without a history of prior CAD and 19% among those with a prior CAD history. Among patients undergoing treadmill exercise, the frequency of stress-only imaging was 48%, while 32% among patients undergoing pharmacologic stress test. In multivariate Cox analysis, there was no significant difference in mortality risk between stress-only and stress/rest protocols in patients with normal SPECT-MPI results (p = 0.271). CONCLUSION Implementation of a stress-first imaging protocol has consistently resulted in safe cancellation of 30% of rest SPECT-MPI studies.
Collapse
Affiliation(s)
- Donghee Han
- Departments of Imaging and Medicine and Burns and Allen Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States of America.
| | - Mark C Hyun
- Departments of Imaging and Medicine and Burns and Allen Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States of America
| | - Robert J H Miller
- Department of Cardiac Sciences, University of Calgary, Calgary, AB, Canada
| | - Heidi Gransar
- Departments of Imaging and Medicine and Burns and Allen Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States of America
| | - Piotr J Slomka
- Departments of Imaging and Medicine and Burns and Allen Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States of America
| | - Damini Dey
- Departments of Imaging and Medicine and Burns and Allen Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States of America
| | - Sean W Hayes
- Departments of Imaging and Medicine and Burns and Allen Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States of America
| | - John D Friedman
- Departments of Imaging and Medicine and Burns and Allen Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States of America
| | - Louise E J Thomson
- Departments of Imaging and Medicine and Burns and Allen Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States of America
| | - Daniel S Berman
- Departments of Imaging and Medicine and Burns and Allen Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States of America
| | - Alan Rozanski
- The Division of Cardiology, Mount Sinai Morningside Hospital, Mount Sinai Heart, and the Icahn School of Medicine at Mount Sinai, New York, NY, United States of America
| |
Collapse
|
7
|
Saednia S, Emami S, Moslehi M, Hosseinimehr SJ. Insights into the development of 99mTc-radioligands for serotonergic receptors imaging: Synthesis, labeling, In vitro, and In vivo studies. Eur J Med Chem 2024; 270:116349. [PMID: 38555856 DOI: 10.1016/j.ejmech.2024.116349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 03/15/2024] [Accepted: 03/18/2024] [Indexed: 04/02/2024]
Abstract
Serotonergic (5-hydroxytryptamine; 5-HT) receptors play critical roles in neurological and psychological disorders such as schizophrenia, anxiety, depression, and Alzheimer's diseases. Therefore, it is particularly important to develop novel radioligands or modify the existing ones to identify the serotonergic receptors involved in psychiatric disorders. Among the 16 subtypes of serotonergic systems, only technetium-99m based radiopharmaceuticals have been evaluated for serotonin-1A (5-HT1A), serotonin-2A (5-HT2A), 5-HT1A/7 heterodimers and serotonin receptor neurotransmitter (SERT). This review focuses on recent efforts in the design, synthesis and evaluation of 99mTc-radioligands used for single photon emission computerized tomography (SPECT) imaging of serotonergic (5-HT) receptors. Additionally, the discussion will cover aspects such as chemical structure, in vitro/vivo stability, affinity toward serotonin receptors, blood-brain barrier permeation (BBB), and biodistribution study.
Collapse
Affiliation(s)
- Shahnaz Saednia
- Farabi Hospital, Isfahan University of Medical Sciences, Isfahan, Iran; Department of Radiopharmacy, Faculty of Pharmacy, Mazandaran University of Medical Sciences, Sari, Iran
| | - Saeed Emami
- Department of Medicinal Chemistry and Pharmaceutical Sciences Research Center, Faculty of Pharmacy, Mazandaran University of Medical Sciences, Sari, Iran
| | - Masoud Moslehi
- Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Seyed Jalal Hosseinimehr
- Department of Radiopharmacy, Faculty of Pharmacy, Mazandaran University of Medical Sciences, Sari, Iran.
| |
Collapse
|
8
|
Kennel SJ, Jackson JW, Stuckey A, Richey T, Foster JS, Wall JS. Preclinical evaluation of Tc-99m p5+14 peptide for SPECT detection of cardiac amyloidosis. PLoS One 2024; 19:e0301756. [PMID: 38578730 PMCID: PMC10997057 DOI: 10.1371/journal.pone.0301756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 03/05/2024] [Indexed: 04/07/2024] Open
Abstract
INTRODUCTION Amyloid deposition is a cause of restrictive cardiomyopathy. Patients who present with cardiac disease can be evaluated for transthyretin (TTR)-associated cardiac amyloidosis using nuclear imaging with 99mTc-labeled pyrophosphate (PYP); however, light chain-associated (AL) cardiac amyloid is generally not detected using this tracer. As an alternative, the amyloid-binding peptide p5+14 radiolabeled with iodine-124 has been shown to be an effective pan-amyloid radiotracer for PET/CT imaging. Here, a 99mTc-labeled form of p5+14 peptide has been prepared to facilitate SPECT/CT imaging of cardiac amyloidosis. METHOD A synthesis method suitable for clinical applications has been used to prepare 99mTc-labeled p5+14 and tested for peptide purity, product bioactivity, radiochemical purity and stability. The product was compared with99mTc-PYP for cardiac SPECT/CT imaging in a mouse model of AA amyloidosis and for reactivity with human tissue sections from AL and TTR patients. RESULTS The 99mTc p5+14 tracer was produced with >95% yields in radiopurity and bioactivity with no purification steps required and retained over 95% peptide purity and >90% bioactivity for >3 h. In mice, the tracer detected hepatosplenic AA amyloid as well as heart deposits with uptake ~5 fold higher than 99mTc-PYP. 99mTc p5+14 effectively bound human amyloid deposits in the liver, kidney and both AL- and ATTR cardiac amyloid in tissue sections in which 99mTc-PYP binding was not detectable. CONCLUSION 99mTc-p5+14 was prepared in minutes in >20 mCi doses with good performance in preclinical studies making it suitable for clinical SPECT/CT imaging of cardiac amyloidosis.
Collapse
Affiliation(s)
- Stephen J. Kennel
- Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States of America
| | - Joseph W. Jackson
- Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States of America
| | - Alan Stuckey
- Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States of America
| | - Tina Richey
- Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States of America
| | - James S. Foster
- Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States of America
| | - Jonathan S. Wall
- Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States of America
| |
Collapse
|
9
|
Budenkotte T, Apostolova I, Opfer R, Krüger J, Klutmann S, Buchert R. Automated identification of uncertain cases in deep learning-based classification of dopamine transporter SPECT to improve clinical utility and acceptance. Eur J Nucl Med Mol Imaging 2024; 51:1333-1344. [PMID: 38133688 PMCID: PMC10957699 DOI: 10.1007/s00259-023-06566-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 12/08/2023] [Indexed: 12/23/2023]
Abstract
PURPOSE Deep convolutional neural networks (CNN) are promising for automatic classification of dopamine transporter (DAT)-SPECT images. Reporting the certainty of CNN-based decisions is highly desired to flag cases that might be misclassified and, therefore, require particularly careful inspection by the user. The aim of the current study was to design and validate a CNN-based system for the identification of uncertain cases. METHODS A network ensemble (NE) combining five CNNs was trained for binary classification of [123I]FP-CIT DAT-SPECT images as "normal" or "neurodegeneration-typical reduction" with high accuracy (NE for classification, NEfC). An uncertainty detection module (UDM) was obtained by combining two additional NE, one trained for detection of "reduced" DAT-SPECT with high sensitivity, the other with high specificity. A case was considered "uncertain" if the "high sensitivity" NE and the "high specificity" NE disagreed. An internal "development" dataset of 1740 clinical DAT-SPECT images was used for training (n = 1250) and testing (n = 490). Two independent datasets with different image characteristics were used for testing only (n = 640, 645). Three established approaches for uncertainty detection were used for comparison (sigmoid, dropout, model averaging). RESULTS In the test data from the development dataset, the NEfC achieved 98.0% accuracy. 4.3% of all test cases were flagged as "uncertain" by the UDM: 2.5% of the correctly classified cases and 90% of the misclassified cases. NEfC accuracy among "certain" cases was 99.8%. The three comparison methods were less effective in labelling misclassified cases as "uncertain" (40-80%). These findings were confirmed in both additional test datasets. CONCLUSION The UDM allows reliable identification of uncertain [123I]FP-CIT SPECT with high risk of misclassification. We recommend that automatic classification of [123I]FP-CIT SPECT images is combined with an UDM to improve clinical utility and acceptance. The proposed UDM method ("high sensitivity versus high specificity") might be useful also for DAT imaging with other ligands and for other binary classification tasks.
Collapse
Affiliation(s)
- Thomas Budenkotte
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany
| | - Ivayla Apostolova
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany
| | | | | | - Susanne Klutmann
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany
| | - Ralph Buchert
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany.
| |
Collapse
|
10
|
Eseonu K, Oduoza U, Robinson P, Easty M, Nadarajah R, Biassoni L. Bone scintigraphy with SPECT/CT in paediatric patients with neck and back pain in comparison with other imaging modalities: the experience of a tertiary paediatric referral centre. Nucl Med Commun 2024; 45:278-286. [PMID: 38214085 DOI: 10.1097/mnm.0000000000001811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2024]
Abstract
OBJECTIVE Retrospective review of the additional clinical value provided by single photon emission computed tomography-computed tomography (SPECT/CT) in children and adolescents with back pain. METHODS A total of 207 consecutive paediatric patients (94 males, 113 females, age range 5-17 years, median age 14 years) were reviewed after referral to the spinal surgery clinic of a paediatric teaching hospital between November 2009 and February 2021. All patients had either only whole spine X-rays or whole spine x-rays and MRI, along with bone scan with planar whole-body images and SPECT/CT (with spot views of painful area). RESULTS X-ray identified the pain generator in 23 of 177 (13.0%) cases. MRI identified the pain generator in 49 of 165 (29.7%) cases. SPECT/CT reported relevant positive findings which identified the pain generator in 107 of 185 (57.8%) cases. SPECT/CT changed patients' management in 72 of 185 (38.9%) cases. SPECT/CT was most effective at identifying the pain generator in cases of facet arthropathy, previous vertebral fracture and patients with previous deformity correction, where the pain generator was identified in 76.5% (13 of 17), 71.4% (5 of 7) and 63.4% (26 of 41) of cases, respectively. CT settings were adjusted to minimise the radiation burden (50 mAs/80kVp under 8 years, 24 mAs/110 kVp over 8 years). CONCLUSION The role of SPECT/CT in diagnosing back pain is justified in selected paediatric patients, particularly with diagnostic uncertainty using conventional imaging. The CT component of the SPECT/CT study produced a lower radiation dose than conventional CT imaging, whilst producing bone images of diagnostic quality.
Collapse
Affiliation(s)
| | | | - Phillip Robinson
- Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust
| | - Marina Easty
- Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust
| | | | - Lorenzo Biassoni
- Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust
| |
Collapse
|
11
|
Derakhshan S, Ghaderi B, Roshani D. Left ventricular mechanical dyssynchrony after chemotherapy in breast cancer patients with normal rest gated SPECT-MPI. Ann Nucl Med 2024; 38:272-277. [PMID: 38244106 DOI: 10.1007/s12149-023-01897-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Accepted: 12/24/2023] [Indexed: 01/22/2024]
Abstract
OBJECTIVES Early diagnosis of chemotherapy-induced cardiotoxicity plays an important role in preventing heart failure. The main aim of our study was to assess left ventricular (LV) dyssynchrony measured by phase analysis of gated single-photon emission computed tomography (SPECT) as an early sign of cardiotoxicity after breast cancer chemotherapy. METHODS This cross-sectional study was conducted on patients with stage ≤ 3 breast cancer and no history of cardiovascular disease or diabetes. After mastectomy, the patients underwent rest gated SPECT myocardial perfusion imaging (MPI). Sixty patients with normal gated SPECT-MPI were selected and the imaging was performed after chemotherapy with doxorubicin, cyclophosphamide and paclitaxel. LV function and contractility parameters were extracted by QGS software and the results were compared with the t test method. The abnormality of at least one of the three phase analysis indices was considered as left ventricular dyssynchrony (LVD). RESULTS The average LV end-systolic volume and ejection fraction (LVEF) before and after chemotherapy were (16.2 ± 8.0 ml and 21.6 ± 11.6 ml) and (73.4 ± 7.9% and 67.5 ± 9.2%) respectively, which showed a significant decrease (P < 0.05). In 2 patients (3.3%), the LVEF decreased to less than 50% after chemotherapy. The average parameters of left ventricular contractility before and after chemotherapy were, respectively, as follows: PHB (24.1 ± 7.5 and 33.8 ± 16.4), PSD (9.4 ± 6.1 and 5.7 ± 1.9) and entropy (28.9 ± 7.1 and 35.6 ± 9.7), which showed a significant increase (P < 0.05). LVD was observed in 14 patients (23.4%) after chemotherapy and prevalence of LVD was significantly higher in patients who had received a cumulative dose of doxorubicin of more than 400 mg/m2 (P = 0.005). There was no relationship between age and body mass index with the incidence of LVD after chemotherapy (P > 0.05). CONCLUSION Using phase analysis of gated SPECT-MPI, chemotherapy-induced LVD was seen in a significant number of patients with breast cancer, especially with a high cumulative dose of doxorubicin. LVD might indicate chemotherapy-induced cardiotoxicity before LVEF becomes abnormal.
Collapse
Affiliation(s)
- Siamak Derakhshan
- Department of Radiotherapy, Faculty of Paramedical Medicine, Kurdistan University of Medical Sciences, Sanandaj, Iran.
| | - Bayazid Ghaderi
- Cancer and Immunology Research Center, Research Institute for Health Development, Kurdistan University of Medical Sciences, Sanandaj, Iran
| | - Daem Roshani
- Department of Epidemiology and Biostatistics, Faculty of Medicine, Kurdistan University of Medical Sciences, Sanandaj, Iran
| |
Collapse
|
12
|
Chung SJ, Kim SH, Park CW, Lee HS, Yun M, Kim YJ, Sohn YH, Jeong Y, Lee PH. Patterns of regional cerebral hypoperfusion in early Parkinson's disease: Clinical implications. Parkinsonism Relat Disord 2024; 121:106024. [PMID: 38377658 DOI: 10.1016/j.parkreldis.2024.106024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Revised: 01/07/2024] [Accepted: 02/01/2024] [Indexed: 02/22/2024]
Abstract
INTRODUCTION This study aimed to investigate whether regional cerebral perfusion patterns on early-phase 18F-FP-CIT PET scans, which is typically coupled to cerebral metabolism, predict the long-term prognosis of Parkinson's disease (PD). METHODS We enrolled 397 drug-naïve patients with early-stage PD who underwent dual-phase 18F-FP-CIT PET scans. After quantifying the early-phase 18F-FP-CIT PET images, cluster analysis was performed to delineate the PD subtypes according to the patterns of regional cerebral perfusion. We compared the risk of developing levodopa-induced dyskinesia (LID), wearing-off, freezing of gait (FOG), and dementia between the PD subtypes. RESULTS Cluster analysis classified patients into three subtypes: cluster 1 (relatively preserved cortical uptake; n = 175), cluster 2 (decreased uptake in the frontal, parietal, and temporal regions; n = 151), and cluster 3 (decreased uptake in more extensive regions, additionally involving the lateral occipital regions; n = 71). Cluster 1 was characterized by a younger age-of-onset, less severe motor deficits, less severely decreased 18F-FP-CIT binding in the caudate, and better cognitive performance. Cluster 3 was characterized by an older age-of-onset, more severe motor deficits, and poorer cognitive performance. Cluster 2 was intermediate between clusters 1 and 3. Cox regression analyses demonstrated that clusters 2 and 3 had a higher risk for dementia conversion than cluster 1, whereas the risk for developing LID, wearing-off, and FOG did not differ among the clusters. CONCLUSION The patterns of regional cerebral perfusion can provide information on long-term prognosis with regards to cognitive, but not motor aspects of patients with early-stage PD.
Collapse
Affiliation(s)
- Seok Jong Chung
- Department of Neurology, Yonsei University College of Medicine, Seoul, South Korea; Department of Neurology, Yongin Severance Hospital, Yonsei University Health System, Yongin, South Korea; YONSEI BEYOND LAB, Yongin, South Korea
| | - Su Hong Kim
- Graduate School of Medical Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea; KAIST Institute for Health Science Technology, Korea Advanced Institute of Science and Technology, Daejeon, South Korea; Department of Radiology, Yeungnam University College of Medicine, Daegu, South Korea
| | - Chan Wook Park
- Department of Neurology, Yonsei University College of Medicine, Seoul, South Korea; Department of Physiology, Yonsei University College of Medicine, Seoul, South Korea
| | - Hye Sun Lee
- Biostatistics Collaboration Unit, Yonsei University College of Medicine, Seoul, South Korea
| | - Mijin Yun
- Department of Nuclear Medicine, Yonsei University College of Medicine, Seoul, South Korea
| | - Yun Joong Kim
- Department of Neurology, Yonsei University College of Medicine, Seoul, South Korea; Department of Neurology, Yongin Severance Hospital, Yonsei University Health System, Yongin, South Korea; YONSEI BEYOND LAB, Yongin, South Korea
| | - Young H Sohn
- Department of Neurology, Yonsei University College of Medicine, Seoul, South Korea
| | - Yong Jeong
- KAIST Institute for Health Science Technology, Korea Advanced Institute of Science and Technology, Daejeon, South Korea; Department of Radiology, Yeungnam University College of Medicine, Daegu, South Korea; Program of Brain and Cognitive Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea; Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea.
| | - Phil Hyu Lee
- Department of Neurology, Yonsei University College of Medicine, Seoul, South Korea; Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul, South Korea.
| |
Collapse
|
13
|
Michler E, Kästner D, Brogsitter C, Pretze M, Hartmann H, Freudenberg R, Schultz MK, Kotzerke J. First-in-human SPECT/CT imaging of [ 212Pb]Pb-VMT-α-NET in a patient with metastatic neuroendocrine tumor. Eur J Nucl Med Mol Imaging 2024; 51:1490-1492. [PMID: 37991526 PMCID: PMC10957691 DOI: 10.1007/s00259-023-06529-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Accepted: 11/14/2023] [Indexed: 11/23/2023]
Affiliation(s)
- Enrico Michler
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - David Kästner
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
| | - Claudia Brogsitter
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Marc Pretze
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Holger Hartmann
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Robert Freudenberg
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | | | - Jörg Kotzerke
- Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany
- Faculty of Medicine Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| |
Collapse
|
14
|
Bao H, Wang N, Chen S, Wang Y, Shao H, Ni Y, Li Y, Liu X, Han X. Multimodal Theranostic Nanoparticles for Necrosis Targeting, Fluorescence/SPECT Imaging, and Radiotherapy of Residual Tumors after Hepatocellular Carcinoma Ablation. Mol Pharm 2024; 21:1729-1744. [PMID: 38449426 DOI: 10.1021/acs.molpharmaceut.3c01081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/08/2024]
Abstract
Thermal ablation has been commonly used as an effective treatment for hepatocellular carcinoma; however, peri-necrotic tumor residues after ablation play a significant role in tumor recurrence and poor prognosis. Therefore, developing agents that can effectively target and eliminate residual tumors is critically needed. Necrosis targeting strategies have potential implications for evaluating tumor necrosis areas and treating the surrounding residual tumors. To address this issue, we have developed a biodegradable nanoparticle with necrosis avidity that is compatible with fluorescence imaging, single photon emission computed tomography (SPECT) imaging, and necrosis targeted radiotherapy. The nanoparticles were synthesized using iodine-131-labeled hypericin (131I-Hyp) as the core and amphiphilic copolymer poly(ethylene glycol)-block-poly(ε-caprolactone) (PEG-PCL) as the shell. The developed nanoparticle, PNP@(131I-Hyp), has a uniform spherical morphology with a size of 33.07 ± 3.94 and 45.93 ± 0.58 nm determined by cryogenic transmission electron microscopy (cryo-TEM) and dynamic light-scattering analysis (polydispersity index = 0.19 ± 0.01), respectively, and having a good stability and blood compatibility in vitro. In mouse subcutaneous ablated-residual tumor models, fluorescence and SPECT imaging demonstrated that PNP@(131I-Hyp) prominently accumulated in the tumor and was retained for as long as 168 h following intravenous injection. Moreover, ex vivo analyses showed that PNP@(131I-Hyp) mainly gathered in the necrotic zones of subcutaneous tumors and inhibited residual tumors by radiotherapy. In addition, histological examination of harvested organs and hematological analysis demonstrated that intravenous injection of 5 mCi/kg nanoparticles caused no gross abnormalities. This multifunctional nanoparticle, therefore, has necrosis imaging and targeted therapeutic effects on residual tumors after thermal ablation of hepatocellular carcinoma, showing potential for clinical application.
Collapse
Affiliation(s)
- Han Bao
- Department of Interventional Radiology, The First Hospital of China Medical University, Shenyang 110001, China
| | - Ning Wang
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang 110001, China
| | - Song Chen
- Department of Nuclear Medicine, The First Hospital of China Medical University, Shenyang 110001, China
| | - Yang Wang
- Department of Chemistry, School of Forensic Medicine, China Medical University, Shenyang 110122, China
| | - Haibo Shao
- Department of Interventional Radiology, The First Hospital of China Medical University, Shenyang 110001, China
| | - Yicheng Ni
- Department of Radiology, Zhongda Hospital, Southeast University, Nanjing 210000, China
| | - Yukang Li
- Department of Interventional Radiology, The First Hospital of China Medical University, Shenyang 110001, China
| | - Xian Liu
- Department of Interventional Radiology, The First Hospital of China Medical University, Shenyang 110001, China
| | - Xiangjun Han
- Department of Interventional Radiology, The First Hospital of China Medical University, Shenyang 110001, China
| |
Collapse
|
15
|
Wang J, Chen Y, Chu H, Pang Z, Hsu B, Li J. Feasibility of myocardial blood flow quantification to detect flow-limited coronary artery disease with a one-day rest/stress continuous rapid imaging protocol on cardiac-dedicated cadmium zinc telluride single photon emission computed tomography. J Nucl Cardiol 2024; 34:101825. [PMID: 38387736 DOI: 10.1016/j.nuclcard.2024.101825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 01/25/2024] [Accepted: 02/11/2024] [Indexed: 02/24/2024]
Abstract
BACKGROUND It is clinically needed to explore a more efficient imaging protocol for single photon emission computed tomography (SPECT) myocardial blood flow (MBF) quantitation derived from cadmium zinc telluride (CZT) SPECT camera for the routine clinical utilization. METHODS One hundred and twenty patients with matched clinical characteristics and angiographic findings who completed one-day rest/stress SPECT imaging with either the intermittently sequential imaging (ISI) protocol (two dynamic and two electrocardiography (ECG)-gated scans) or the continuous rapid imaging (CRI) protocol (two dynamic/ECG-gated scans) were included. MBF quantitation adopted residual activity correction (RAC) to correct for rest residual activity (RRA) in the stress dynamic SPECT scan for the detection of flow-limited coronary artery disease. RESULTS The CRI protocol reduced about 6.2 times shorter than the ISI protocol (25.5 min vs 157.6 min), but slightly higher than the RRA (26.7% ± 3.6% vs 22.3% ± 4.9%). With RAC, both protocols demonstrated close stress MBF (2.18 ± 1.13 vs 2.05 ± 1.10, P > 0.05) and myocardial flow reserve (MFR) (2.42 ± 1.05 vs 2.48 ± 1.11, P > 0.05) to deliver comparable diagnostic performance (sensitivity = 82.1%-92.3%, specificity = 81.2%-91.2%). Myocardial perfusion and left ventricular function overall showed no significant difference (all P > 0.26). CONCLUSION One-day rest/stress SPECT with the CRI protocol and rest RAC is feasible to warrant the diagnostic performance of MBF quantitation with a shortened examination time and enhanced patient comfort. Further evaluation on the impact of extracardiac activity to regional MBF and perfusion pattern is required. Additional evaluation is needed in a patient population that is typical of those referred for SPECT MPI, including those with known or suspected coronary microvascular disease.
Collapse
Affiliation(s)
- Jiao Wang
- Nuclear Medicine Department, TEDA International Cardiovascular Hospital, Tianjin, China
| | - Yue Chen
- Nuclear Medicine Department, TEDA International Cardiovascular Hospital, Tianjin, China
| | - Hongxin Chu
- Nuclear Medicine Department, TEDA International Cardiovascular Hospital, Tianjin, China
| | - Zekun Pang
- Nuclear Medicine Department, TEDA International Cardiovascular Hospital, Tianjin, China
| | - Bailing Hsu
- Nuclear Science and Engineering Institute, University of Missouri-Columbia, Columbia, MO, USA.
| | - Jianming Li
- Nuclear Medicine Department, TEDA International Cardiovascular Hospital, Tianjin, China.
| |
Collapse
|
16
|
Bahloul A, Verger A, Lamash Y, Roth N, Dari D, Marie PY, Imbert L. Ultra-fast whole-body bone tomoscintigraphies achieved with a high-sensitivity 360° CZT camera and a dedicated deep-learning noise reduction algorithm. Eur J Nucl Med Mol Imaging 2024; 51:1215-1220. [PMID: 38082197 DOI: 10.1007/s00259-023-06558-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 12/01/2023] [Indexed: 03/22/2024]
Abstract
This study aimed to determine whether the whole-body bone Single Photon Emission Computed Tomography (SPECT) recording times of around 10 min, routinely provided by a high-sensitivity 360° cadmium and zinc telluride (CZT) camera, can be further reduced by a deep-learning noise reduction (DLNR) algorithm. METHODS DLNR was applied on whole-body images recorded after the injection of 545 ± 33 MBq of [99mTc]Tc-HDP in 19 patients (14 with bone metastasis) and reconstructed with 100%, 90%, 80%, 70%, 60%, 50%, 40%, and 30% of the original SPECT recording times. RESULTS Irrespective of recording time, DLNR enhanced the contrast-to-noise ratios and slightly decreased the standardized uptake values of bone lesions. Except in one markedly obese patient, the quality of DLNR processed images remained good-to-excellent down to 60% of the recording time, corresponding to around 6 min SPECT-recording. CONCLUSION Ultra-fast SPECT recordings of 6 min can be achieved when DLNR is applied on whole-body bone 360° CZT-SPECT.
Collapse
Affiliation(s)
- Achraf Bahloul
- CHRU-Nancy, Department of Nuclear Medicine & Nancyclotep imaging platform, Université de Lorraine, Nancy, France
- INSERM, IADI U1254, Université de Lorraine, Vandoeuvre-lès-Nancy, France
| | - Antoine Verger
- CHRU-Nancy, Department of Nuclear Medicine & Nancyclotep imaging platform, Université de Lorraine, Nancy, France
- INSERM, IADI U1254, Université de Lorraine, Vandoeuvre-lès-Nancy, France
| | | | | | - Diawad Dari
- CHRU-Nancy, Department of Nuclear Medicine & Nancyclotep imaging platform, Université de Lorraine, Nancy, France
| | - Pierre-Yves Marie
- CHRU-Nancy, Department of Nuclear Medicine & Nancyclotep imaging platform, Université de Lorraine, Nancy, France
- INSERM, IADI U1254, Université de Lorraine, Vandoeuvre-lès-Nancy, France
| | - Laetitia Imbert
- CHRU-Nancy, Department of Nuclear Medicine & Nancyclotep imaging platform, Université de Lorraine, Nancy, France.
- INSERM, IADI U1254, Université de Lorraine, Vandoeuvre-lès-Nancy, France.
| |
Collapse
|
17
|
Hu B, Ma X, Shi L, Liu T, Li L, Yao M, Li C, Jia B. Noninvasive Evaluation of Tumoral PD-L1 Using a Novel 99mTc-Labeled Nanobody Tracer with Rapid Renal Clearance. Mol Pharm 2024; 21:1977-1986. [PMID: 38395797 DOI: 10.1021/acs.molpharmaceut.3c01219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2024]
Abstract
The expression level of PD-L1 in tumor tissue is considered one of the effective biomarkers to guide PD-1/PD-L1 therapy. Quantifying whole-body PD-L1 expression by SPECT imaging may help in selecting patients that potentially respond to PD-1/PD-L1 therapy. Nanobody is the smallest antibody fragment with antigen-binding ability that is well suited for radionuclide imaging. Nevertheless, high retention of radioactivity in the kidney may limit its clinical translation. The present study aimed to screen, design, and prepare a nanobody-based SPECT probe with rapid renal clearance to evaluate the PD-L1 expression level in vivo noninvasively. A phage library was constructed by immunizing alpaca with recombinant human PD-L1 protein, and 17 anti-PD-L1 nanobodies were screened by the phage display technique. After sequence alignment and flow cytometry analysis, APN09 was selected as the candidate nanobody, and a GGGC chelator was attached to its C-terminus for 99mTc labeling to prepare a SPECT imaging probe. The affinity and specificity of 99mTc-APN09 were evaluated by protein and cell-binding experiments, and SPECT imaging and biodistribution were performed in a mouse model with bilateral transplantation of A549 and A549PD-L1 tumors. The ability of 99mTc-APN09 to quantify the PD-L1 expression level in vivo was validated in tumor models with different PD-L1 expression levels. 99mTc-APN09 had a radiochemical purity higher than 99% and a binding equilibrium dissociation constant of 21.44 ± 1.65 nM with hPD-L1, showing high affinity. SPECT imaging results showed that 99mTc-APN09 could efficiently detect PD-L1-positive tumors within 0.5 h, and the quantitative results of SPECT were well correlated with the expression level of PD-L1 in cell lines. SPECT imaging and biodistribution results also showed that 99mTc-APN09 was rapidly cleared from the kidney in 2 h postinjection. 99mTc-APN09 was a simple and stable tool for visualizing PD-L1 expression in the whole body. In addition, due to its significant reduction in renal retention, it has better prospects for clinical translation.
Collapse
Affiliation(s)
- Biao Hu
- Department of Radiation Medicine, School of Basic Medical Sciences, Peking University, Beijing 100191, China
- Department of Nuclear Medicine, Molecular Imaging Lab, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China
| | - Xiaopan Ma
- Department of Nuclear Medicine, Peking University Cancer Hospital & Institute, Beijing 100142, China
| | - Linqing Shi
- Department of Radiation Medicine, School of Basic Medical Sciences, Peking University, Beijing 100191, China
| | - Tianyu Liu
- Department of Radiation Medicine, School of Basic Medical Sciences, Peking University, Beijing 100191, China
| | - Liqiang Li
- Department of Radiation Medicine, School of Basic Medical Sciences, Peking University, Beijing 100191, China
| | - Meinan Yao
- Department of Radiation Medicine, School of Basic Medical Sciences, Peking University, Beijing 100191, China
| | - Chenzhen Li
- Department of Radiation Medicine, School of Basic Medical Sciences, Peking University, Beijing 100191, China
| | - Bing Jia
- Department of Radiation Medicine, School of Basic Medical Sciences, Peking University, Beijing 100191, China
- Department of Integration of Chinese and Western Medicine, School of Basic Medical Sciences, Peking University, Beijing 100191, China
| |
Collapse
|
18
|
Ruddy TD, Wells RG. Shortening the acquisition times of CZT SPECT imaging for measurement of myocardial blood flow. J Nucl Cardiol 2024; 34:101847. [PMID: 38467185 DOI: 10.1016/j.nuclcard.2024.101847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 03/08/2024] [Indexed: 03/13/2024]
Affiliation(s)
- Terrence D Ruddy
- Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada.
| | - R Glenn Wells
- Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada
| |
Collapse
|
19
|
Karssemakers LHE, Besseling LMP, Schoonmade LJ, Su N, Nolte JW, Raijmakers PG, Becking AG. Diagnostic accuracy of bone SPECT and SPECT/CT imaging in the diagnosis of unilateral condylar hyperplasia: A systematic review and meta-analysis. J Craniomaxillofac Surg 2024; 52:447-453. [PMID: 38378369 DOI: 10.1016/j.jcms.2024.01.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2023] [Revised: 10/26/2023] [Accepted: 01/16/2024] [Indexed: 02/22/2024] Open
Abstract
Imaging with bone scans plays an important role in the diagnostic path of patients with unilateral condylar hyperactivity or unilateral condylar hyperplasia (UCH). The aim of this study is to perform a systematic review of the diagnostic performance of the bone SPECT and SPECT/CT scan for the diagnosis of UCH. PubMed, SCOPUS and EMBASE were searched electronically to identify diagnostic accuracy studies that assessed the diagnostic value of bone SPECT and SPECT/CT for the diagnosis of UCH, Meta-analyses were performed with Metadisc 1.4 and 2.0. A total of 14 studies, with a total number of 887 patients, were included in the qualitative analysis and 11 studies qualified for meta-analyses. The pooled sensitivity and specificity for the SPECT scan were 0.814 (95 % CI: 0.639-0.915) and 0.774 (95 % CI: 0.655-0.861), for the SPECT/CT scan these were 0.818 (95 % CI: 0.749-0.874) and 0.901 (95 % CI: 0.840-0.945). The summary receiver operating characteristics of the SPECT scan showed an area under the curve of 0.847 (95 % CI: 0.722-0.972) and that of the SPECT/CT scan was 0.928 (95 % CI: 0.876-0.980). CONCLUSION: Both bone SPECT scan and SPECT/CT scan provide a high diagnostic accuracy for UCH. The added value of the SPECT/CT scan is questionable and given the potential disadvantages of the SPECT/CT scan, including the increased radiation dose and costs, the diagnostic modality of first choice in patients with UCH should be a SPECT scan.
Collapse
Affiliation(s)
- L H E Karssemakers
- Department of Oral and Maxillofacial Surgery, Amsterdam UMC/Emma Children's Hospital, and Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam, Amsterdam, the Netherlands; Department of Head and Neck Surgery & Oncology, Netherlands Cancer Institute, Antoni Van Leeuwenhoek, Amsterdam, the Netherlands.
| | - L M P Besseling
- Department of Oral and Maxillofacial Surgery, Amsterdam UMC/Emma Children's Hospital, and Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam, Amsterdam, the Netherlands
| | - L J Schoonmade
- Medical Library, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - N Su
- Department of Oral and Maxillofacial Surgery, Amsterdam UMC/Emma Children's Hospital, and Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam, Amsterdam, the Netherlands; Department of Oral Public Health, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - J W Nolte
- Department of Oral and Maxillofacial Surgery, Amsterdam UMC/Emma Children's Hospital, and Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam, Amsterdam, the Netherlands
| | - P G Raijmakers
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - A G Becking
- Department of Oral and Maxillofacial Surgery, Amsterdam UMC/Emma Children's Hospital, and Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam, Amsterdam, the Netherlands; Department of Oral and Maxillofacial Surgery, MKA Kennemer & Meer, Haarlem, the Netherlands
| |
Collapse
|
20
|
Fastner S, Creveling P, Shen N, Horns JJ, Bowles TL, Hyngstrom J, Asare EA. Single-Photon Emission Computed Tomography/Computed Tomography Utilization for Extremity Melanomas at a High-Volume Center. J Surg Res 2024; 296:196-202. [PMID: 38277957 DOI: 10.1016/j.jss.2023.12.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 11/22/2023] [Accepted: 12/23/2023] [Indexed: 01/28/2024]
Abstract
INTRODUCTION Planar lymphoscintigraphy (PL) is commonly used in mapping before sentinel lymph node biopsy (SLNB) for invasive cutaneous melanoma. Recently, single-photon emission computed tomography (SPECT)/ computed tomography (CT) has been utilized, in addition to PL, for detailed anatomic information and detection of sentinel lymph nodes (SLNs) outside of the primary nodal basin in truncal and head and neck melanoma. Following a protocol change due to COVID-19, our institution began routinely obtaining both PL and SPECT-CT imaging for all melanoma SLN mapping. We hypothesized that SPECT-CT is associated with higher instances of SLNBs from "nontraditional" nodal basins (NTNB) for extremity melanomas. METHODS Patients with extremity melanoma (2017-2022) who underwent SLNB were grouped into SPECT-CT with PL versus PL alone. Outcomes were total SLNs removed, + or-SLN status, total NTNB sampled, and postoperative complication rate. Poisson regression and logistic regression models were used to assess association of SPECT-CT with patient outcomes. RESULTS Of 380 patients with extremity melanoma, 42.11% had SPECT-CT. There were no differences between the groups with regards to age at diagnosis or sex. From 2020 to 2022, all patients underwent SPECT-CT. SPECT-CT was associated with increased odds of SLNB from an NTNB, (odds ratio = 2.39 [95% confidence interval: 1.25-4.67]). There was no difference in odds of number of SLNs sampled, SLN positivity rate, or postoperative complication rate with SPECT-CT. CONCLUSIONS Routine SPECT-CT was associated with higher incidence of SLNB in NTNB but did not increase number of SLNs removed or SLN positivity rate. The added value of routine SPECT-CT in cutaneous melanoma of the extremities remains to be defined.
Collapse
Affiliation(s)
| | - Polly Creveling
- Spencer Fox Eccles School of Medicine, University of Utah, Salt Lake City, Utah
| | - Nathan Shen
- Huntsman Cancer Institute, Salt Lake City, Utah
| | - Joshua J Horns
- Department of Surgery, University of Utah, Salt Lake City, Utah
| | - Tawnya L Bowles
- Department of Surgery, Intermountain Medical Center, Murray, Utah
| | - John Hyngstrom
- Huntsman Cancer Institute, Salt Lake City, Utah; Department of Surgery, University of Utah, Salt Lake City, Utah
| | - Elliot A Asare
- Huntsman Cancer Institute, Salt Lake City, Utah; Department of Surgery, University of Utah, Salt Lake City, Utah.
| |
Collapse
|
21
|
Wang H, Li X, Xu L, Kuang Y. PET/SPECT/spectral-CT/CBCT imaging in a small-animal radiation therapy platform: A Monte Carlo study-Part I: Quad-modal imaging. Med Phys 2024; 51:2941-2954. [PMID: 38421665 DOI: 10.1002/mp.17007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 01/16/2024] [Accepted: 02/12/2024] [Indexed: 03/02/2024] Open
Abstract
BACKGROUND In spite of the tremendous potential of game-changing biological image- and/or biologically guided radiation therapy (RT) and adaptive radiation therapy for cancer treatment, existing limited strategies for integrating molecular imaging and/or biological information with RT have impeded the translation of preclinical research findings to clinical applications. Additionally, there is an urgent need for a highly integrated small-animal radiation therapy (SART) platform that can seamlessly combine therapeutic and diagnostic capabilities to comprehensively enhance RT for cancer treatment. PURPOSE We investigated a highly integrated quad-modal on-board imaging configuration combining positron emission tomography (PET), single-photon emission computed tomography (SPECT), photon-counting spectral CT, and cone-beam computed tomography (CBCT) in a SART platform using a Monte Carlo model as a proof-of-concept. METHODS The quad-modal on-board imaging configuration of the SART platform was designed and evaluated by using the GATE Monte Carlo code. A partial-ring on-board PET imaging subsystem, utilizing advanced semiconductor thallium bromide detector technology, was designed to achieve high sensitivity and spatial resolution. On-board SPECT, photon-counting spectral-CT, and CBCT imaging were performed using a single cadmium zinc telluride flat detector panel. The absolute peak sensitivity and scatter fraction of the PET subsystem were estimated by using simulated phantoms described in the NEMA NU-4 standard. The spatial resolution of the PET image of the platform was evaluated by imaging a simulated micro-Derenzo hot-rod phantom. To evaluate the quantitative imaging capability of the system's spectral CT, the Bayesian eigentissue decomposition (ETD) method was utilized to quantitatively decompose the virtual noncontrast (VNC) electron densities and iodine contrast agent fractions in the Kidney1 inserts mixed with the iodine contrast agent within the simulated phantoms. The performance of the proposed quad-model imaging in the platform was validated by imaging a simulated phantom with multiple imaging probes, including an iodine contrast agent and radioisotopes of 18F and 99mTc. RESULTS The PET subsystem demonstrated an absolute peak sensitivity of 18.5% at the scanner center, with an energy window of 175-560 KeV, and a scatter fraction of only 3.5% for the mouse phantom, with a default energy window of 480-540 KeV. The spatial resolution of PET on-board imaging exceeded 1.2 mm. All imaging probes were identified clearly within the phantom. The PET and SPECT images agreed well with the actual spatial distributions of the tracers within the phantom. Average relative errors on electron density and iodine contrast agent fraction in the Kidney1 inserts were less than 3%. High-quality PET images, SPECT images, spectral-CT images (including iodine contrast agent fraction images and VNC electron density images), and CBCT images of the simulated phantom demonstrated the comprehensive multimodal imaging capability of the system. CONCLUSIONS The results demonstrated the feasibility of the proposed quad-modal imaging configuration in a SART platform. The design incorporates anatomical, molecular, and functional information about tumors, thereby facilitating successful translation of preclinical studies into clinical practices.
Collapse
Affiliation(s)
- Hui Wang
- Medical Imaging and Translational Medicine Laboratory, Department of Radiotherapy, Affiliated Hangzhou Cancer Hospital, Westlake University School of Medicine, Hangzhou, Zhejiang, China
- Medical Physics Program, University of Nevada, Las Vegas, Nevada, USA
| | - Xiadong Li
- Medical Imaging and Translational Medicine Laboratory, Department of Radiotherapy, Affiliated Hangzhou Cancer Hospital, Westlake University School of Medicine, Hangzhou, Zhejiang, China
| | - Lixia Xu
- Medical Imaging and Translational Medicine Laboratory, Department of Radiotherapy, Affiliated Hangzhou Cancer Hospital, Westlake University School of Medicine, Hangzhou, Zhejiang, China
| | - Yu Kuang
- Medical Physics Program, University of Nevada, Las Vegas, Nevada, USA
| |
Collapse
|
22
|
Kolade OU, Brink A, Ayeni AO, More S, Holness J. Optimizing PSMA scintigraphy for resource limited settings - a retrospective comparative study. Cancer Imaging 2024; 24:46. [PMID: 38556864 PMCID: PMC10983723 DOI: 10.1186/s40644-024-00693-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 03/20/2024] [Indexed: 04/02/2024] Open
Abstract
BACKGROUND PSMA PET/CT is the most sensitive molecular imaging modality for prostate cancer (PCa), yet much of the developing world has little or no access to PET/CT. [99mTc]Tc-PSMA scintigraphy (PS) is a cheaper and more accessible gamma camera-based alternative. However, many resource-constrained departments have only a single camera without tomographic or hybrid imaging functionality, and camera time is frequently in high demand. Simplifying imaging protocols by limiting the field of view (FOV) and omitting SPECT/CT or even SPECT may provide a partial solution. The aim was thus to determine the adequacy of PS planar-only and/or SPECT-only imaging protocols with a limited FOV. METHODS The scans of 95 patients with histologically proven PCa who underwent PS with full-body planar and multi-FOV SPECT/CT were reviewed. The detection rates for uptake in the prostate gland/bed and in metastases were compared on planar, SPECT, and SPECT/CT. The agreement between modalities was calculated for the detection of metastases and for staging. The impact of imaging a limited FOV was determined. RESULTS Pathological prostatic uptake was seen in all cases on SPECT/CT (excluding two post-prostatectomy patients), 90.3% of cases on SPECT, and 15.1% on planar images (p < 0.001). Eleven (11.7%) patients had seminal vesicle involvement on SPECT/CT, which was undetectable/indistinguishable on planar images and SPECT. The agreement between modalities was moderate to good (κ = 0.41 to 0.61) for the detection of nodal metastases, with detection rates that did not differ significantly (SPECT/CT = 11.6%, SPECT = 8.4%, planar = 5.3%). Detection rates for bone metastases were 14.7% (SPECT/CT) and 11.6% (SPECT and planar). Agreement between modalities for the detection of bone metastases was good (κ = 0.73 to 0.77). Three (3.1%) patients had visceral metastases on SPECT/CT, two of which were detected on SPECT and planar. There was good agreement between modalities for the TNM staging of patients (κ = 0.70 to 0.88). No metastatic lesions were missed on the limited FOV images. CONCLUSION When PS scintigraphy is performed, SPECT/CT is recommended. However, the lack of SPECT/CT capabilities should not preclude the use of PS in the presence of limited resources, as both planar and SPECT imaging are adequate and will correctly stage most PCa patients. Furthermore, time-based optimisations are achievable by limiting the FOV to exclude the distal lower limbs.
Collapse
Affiliation(s)
- Olumayowa U Kolade
- Division of Nuclear Medicine, Department of Radiation Medicine, University of Cape Town, Cape Town, South Africa.
- Department of Nuclear Medicine, University College Hospital, Ibadan, Oyo State, Nigeria.
| | - Anita Brink
- Division of Nuclear Medicine, Department of Radiation Medicine, University of Cape Town, Cape Town, South Africa
- Division of Human Health, Department of Nuclear Sciences and Applications, International Atomic Energy Agency (IAEA), Vienna, Austria
| | - Akinwale O Ayeni
- Division of Nuclear Medicine, Department of Radiation Medicine, University of Cape Town, Cape Town, South Africa
- Department of Nuclear Medicine, Klerksdorp/Tshepong Hospital Complex, Klerksdorp, South Africa
- Division of Nuclear Medicine, Department of Radiation Sciences, University of the Witwatersrand, Johannesburg, South Africa
| | - Stuart More
- Division of Nuclear Medicine, Department of Radiation Medicine, University of Cape Town, Cape Town, South Africa
| | - Jennifer Holness
- Division of Nuclear Medicine, Department of Radiation Medicine, University of Cape Town, Cape Town, South Africa
- Division of Nuclear Medicine, Department of Medical Imaging and Clinical Oncology, Stellenbosch University, Cape Town, South Africa
| |
Collapse
|
23
|
Liu J, Kang J, Qi M, Tang J, Fang Y, Liu C, Hong J, Zuo J, Chen Z. Synthesis and initial evaluation of radioiodine-labelled deuterated tropane derivatives targeting dopamine transporter. Bioorg Med Chem Lett 2024; 102:129678. [PMID: 38408514 DOI: 10.1016/j.bmcl.2024.129678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 02/21/2024] [Accepted: 02/23/2024] [Indexed: 02/28/2024]
Abstract
The dopamine transporter (DAT) is closely related to a variety of neurological disorders including Parkinson's disease (PD) and other neurodegenerative diseases. In vivo imaging of DAT with radio-labelled tracers has become a powerful technique in related disorders. The radioiodine-labelled tropane derivative [123I]FP-CIT ([123I]1a) is widely used in clinical single photon emission computed tomography (SPECT) imaging as a DAT imaging agent. To develop more metabolically stable DAT radioligands for accurate imaging, this work compared two novel deuterated tropane derivatives ([131I]1c-d) with non-deuterated tropane derivatives ([131I]1a-b). [131I]1a-d were obtained in high radiochemical purity (RCP) above 99 % with molar activities of 7.0-10.0 GBq/μmol. The [131I]1a and [131I]1c exhibited relatively higher affinity to DAT (Ki: 2.0-3.12 nM) than [131I]1b and [131I]1d. Biodistribution results showed that [131I]1c consistently exhibited a higher ratio of the target to non-target (striatum/cerebellum) than [131I]1a. Furthermore, metabolism studies indicated that the in vivo metabolic stability of [131I]1c was superior to that of [131I]1a. Ex vivo autoradiography showed that [131I]1c selectively localized on DAT-rich striatal regions and the specific signal could be blocked by DAT inhibitor. These results indicated that [131I]1c might be a potential probe for DAT SPECT imaging in the brain.
Collapse
Affiliation(s)
- Jie Liu
- Department of Radiopharmaceuticals, School of Pharmacy, Nanjing Medical University, Nanjing 211166, China; NHC Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063, China
| | - Jing Kang
- Department of Radiopharmaceuticals, School of Pharmacy, Nanjing Medical University, Nanjing 211166, China; NHC Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063, China
| | - Meihui Qi
- NHC Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063, China; School of Pharmaceutical Science, Inner Mongolia Medical University, Hohhot 010110, China
| | - Jie Tang
- NHC Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063, China
| | - Yi Fang
- NHC Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063, China
| | - Chunyi Liu
- NHC Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063, China
| | - Jingjing Hong
- NHC Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063, China; Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy, School of Pharmacy, Xuzhou Medical University, Xuzhou 221004, China
| | - Jiaojiao Zuo
- NHC Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063, China; School of Pharmaceutical Science, Inner Mongolia Medical University, Hohhot 010110, China
| | - Zhengping Chen
- Department of Radiopharmaceuticals, School of Pharmacy, Nanjing Medical University, Nanjing 211166, China; NHC Key Laboratory of Nuclear Medicine, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063, China; School of Pharmaceutical Science, Inner Mongolia Medical University, Hohhot 010110, China; Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy, School of Pharmacy, Xuzhou Medical University, Xuzhou 221004, China.
| |
Collapse
|
24
|
Piatkova Y, Doyen M, Heyer S, Tahmazov A, Frismand S, Hopes L, Imbert L, Verger A. Effects of medication on dopamine transporter imaging using [ 123I]I-FP-CIT SPECT in routine practice. Eur J Nucl Med Mol Imaging 2024; 51:1323-1332. [PMID: 38114618 DOI: 10.1007/s00259-023-06565-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Accepted: 12/08/2023] [Indexed: 12/21/2023]
Abstract
PURPOSE Dopamine transporter (DAT) imaging is used to support the diagnosis of neurodegenerative parkinsonian disorders. Specific medications have been reported to confound the interpretation of [123I]I-FP-CIT SPECT scans, but there is limited data. The aim of the current study is to identify potential medication effects on the interpretation of [123I]I-FP-CIT SPECT scans in routine practice. MATERIALS AND METHODS Consecutive patients undergoing a [123I]I-FP-CIT SPECT/CT scan on a 360° CZT camera between September 2019 and December 2022 were included. An exhaustive review of patient medications (antidepressants, antipsychotics, anti-epileptics, anti-parkinsonians, benzodiazepines, lithium, opioids, and stimulants) was performed. Two experienced nuclear physicians, blinded to the medication reports, interpreted the [123I]I-FP-CIT SPECT scans visually and a semi-quantitative analysis was performed using a local normal database. RESULTS The study included 305 patients (71.0 ± 10.4, 135 women) and 145 (47.5%) visually interpreted normal scans. In normal scans, the striatum/occiput radioligand uptake ratio was decreased by noradrenergic and specific serotonergic antidepressants (NASSAs) (n = 15, z-score of - 0.93) and opioid medication (tramadol, n = 6, z-score of - 0.85) and was associated with a younger age in the multivariate analysis. In the overall population, the striatum/occiput ratio was influenced by NASSAs and associated with consensual visual analysis, age, sex, and anti-parkinsonian medications related to the status of the disease. CONCLUSION Our study confirms the potential impact of antidepressant (NASSA) and opioid (tramadol) medications on the semi-quantitative analysis of [123I]I-FP-CIT SPECT scans. However, when performing a visual analysis, only NASSAs significantly impacted the interpretation of [123I]I-FP-CIT SPECT scans.
Collapse
Affiliation(s)
- Yuliya Piatkova
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, Université de Lorraine, CHRU Nancy, F-54000, Nancy, France
| | - Matthieu Doyen
- IADI, INSERM U1254, Université de Lorraine, F-54000, Nancy, France
| | - Sébastien Heyer
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, Université de Lorraine, CHRU Nancy, F-54000, Nancy, France
| | - Ayaz Tahmazov
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, Université de Lorraine, CHRU Nancy, F-54000, Nancy, France
| | - Solene Frismand
- Department of Neurology, Université de Lorraine, CHRU de Nancy, F-54000, Nancy, France
| | - Lucie Hopes
- Department of Neurology, Université de Lorraine, CHRU de Nancy, F-54000, Nancy, France
| | - Laetitia Imbert
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, Université de Lorraine, CHRU Nancy, F-54000, Nancy, France
- IADI, INSERM U1254, Université de Lorraine, F-54000, Nancy, France
| | - Antoine Verger
- Department of Nuclear Medicine and Nancyclotep Imaging Platform, Université de Lorraine, CHRU Nancy, F-54000, Nancy, France.
- IADI, INSERM U1254, Université de Lorraine, F-54000, Nancy, France.
| |
Collapse
|
25
|
Curkic Kapidzic S, Gustafsson J, Larsson E, Jessen L, Sjögreen Gleisner K. Kidney dosimetry in [ 177Lu]Lu-DOTA-TATE therapy based on multiple small VOIs. Phys Med 2024; 120:103335. [PMID: 38555793 DOI: 10.1016/j.ejmp.2024.103335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 01/24/2024] [Accepted: 03/21/2024] [Indexed: 04/02/2024] Open
Abstract
PURPOSE The aim was to investigate the use of multiple small VOIs for kidney dosimetry in [177Lu]Lu-DOTA-TATE therapy. METHOD The study was based on patient and simulated SPECT images in anthropomorphic geometries. Images were reconstructed using two reconstruction programs (local LundaDose and commercial Hermia) using OS-EM with and without resolution recovery (RR). Five small VOIs were placed to determine the average activity concentration (AC) in each kidney. The study consisted of three steps: (i) determination of the number of iterations for AC convergence based on simulated images; (ii) determination of recovery-coefficients (RCs) for 2 mL VOIs using a separate set of simulated images; (iii) assessment of operator variability in AC estimates for simulated and patient images. Five operators placed the VOIs, using for guidance: a) SPECT/CT with RR, b) SPECT/CT without RR, and c) CT only. For simulated images, time-integrated ACs (TIACs) were evaluated. For patient images, estimated ACs were compared with results of a previous method based on whole-kidney VOIs. RESULTS Eight iterations and ten subsets were sufficient for both programs and reconstruction settings. Mean RCs (mean ± SD) with RR were 1.03 ± 0.02 (LundaDose) and 1.10 ± 0.03 (Hermia), and without RR 0.91 ± 0.03 (LundaDose) and 0.94 ± 0.03 (Hermia). Most stable and accurate estimates of the AC were obtained using five 2-mL VOIs guided by SPECT/CT with RR, applying them to images without RR, and including an explicit RC for recovery correction. CONCLUSION The small VOI method based on five 2-mL VOIs was found efficient and sufficiently accurate for kidney dosimetry in [177Lu]Lu-DOTA-TATE therapy.
Collapse
Affiliation(s)
- Selma Curkic Kapidzic
- Medical Radiation Physics, Lund, Lund University, Lund, Sweden; Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Sweden.
| | | | - Erik Larsson
- Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Sweden
| | - Lovisa Jessen
- Medical Radiation Physics, Lund, Lund University, Lund, Sweden
| | | |
Collapse
|
26
|
Miyagawa M, Nakajima Y, Murata N, Okumura Y. Potential Benefits of Non-Gated Computed Tomography for an Early Invasive Strategy in Ventricular Fibrillation. Circ J 2024; 88:614. [PMID: 38382973 DOI: 10.1253/circj.cj-23-0855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Affiliation(s)
- Masatsugu Miyagawa
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine
| | - Yuki Nakajima
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine
| | - Nobuhiro Murata
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine
| | - Yasuo Okumura
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine
| |
Collapse
|
27
|
Fredensborg FLH, Thilsing-Hansen K, Simonsen JA, Grupe P, Farahani ZA, Andersen CW, Gjedde A, Hvidsten S. Dynamic multi-pinhole collimated brain SPECT of Parkinson's disease by [ 123I]FP-CIT: a feasibility study of fSPECT. Sci Rep 2024; 14:6624. [PMID: 38503852 PMCID: PMC10951323 DOI: 10.1038/s41598-024-57152-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 03/13/2024] [Indexed: 03/21/2024] Open
Abstract
We investigated the feasibility of using a dopamine transporter (DaT) tracer ligand ([123I]FP-CIT) along with novel multi-pinhole brain collimators for dynamic brain single photon emission computed tomography (SPECT) in suspected Parkinson's disease patients. Thirteen patients underwent dynamic tracer acquisitions before standard imaging. Uptake values were corrected for partial volume effects. Specific binding ratio (SBRcalc) was calculated, reflecting binding potential relative to non-displaceable binding (BPND) in the cortex. Additional pharmacokinetic parameters (BPND, R1, k2) were estimated using the simplified reference tissue model, revealing differences between Kahraman low-score (LS) and high-score (HS) groups. Results showed increasing striatal tracer uptake until 100 min post-injection, with consistent values afterward. Uptake and SBRcalc ratios matched visual assessment. LS patients had lower putamen than caudate nucleus tracer uptake, decreased BPND values, while R1 and k2 values were comparable to HS patients. In conclusion, dynamic multi-pinhole SPECT using DaT tracer with the extraction of pharmacokinetic parameters is feasible and could help enable early differentiation of reduced and normal DaT values.
Collapse
Affiliation(s)
- Filip L H Fredensborg
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark.
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark.
| | | | - Jane A Simonsen
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Peter Grupe
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Ziba A Farahani
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark
| | | | - Albert Gjedde
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark
- Translational Neuropsychiatry Unit, Aarhus University and Aarhus University Hospital, Aarhus, Denmark
- Department of Neuroscience, University of Copenhagen, Copenhagen, Denmark
- Department of Neurology and Neurosurgery, McGill University, Montréal, Québec, Canada
| | - Svend Hvidsten
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark
| |
Collapse
|
28
|
Miyai M, Fukui R, Nakashima M, Goto S. Deep learning-based attenuation correction method in 99mTc-GSA SPECT/CT hepatic imaging: a phantom study. Radiol Phys Technol 2024; 17:165-175. [PMID: 38032506 DOI: 10.1007/s12194-023-00762-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 10/15/2023] [Accepted: 11/02/2023] [Indexed: 12/01/2023]
Abstract
This study aimed to evaluate a deep learning-based attenuation correction (AC) method to generate pseudo-computed tomography (CT) images from non-AC single-photon emission computed tomography images (SPECTNC) for AC in 99mTc-galactosyl human albumin diethylenetriamine pentaacetic acid (GSA) scintigraphy and to reduce patient dosage. A cycle-consistent generative network (CycleGAN) model was used to generate pseudo-CT images. The training datasets comprised approximately 850 liver phantom images obtained from SPECTNC and real CT images. The training datasets were then input to CycleGAN, and pseudo-CT images were output. SPECT images with real-time CT attenuation correction (SPECTCTAC) and pseudo-CT attenuation correction (SPECTGAN) were acquired. The difference in liver volume between real CT and pseudo-CT images was evaluated. Total counts and uniformity were then used to evaluate the effects of AC. Additionally, the similarity coefficients of SPECTCTAC and SPECTGAN were assessed using a structural similarity (SSIM) index. The pseudo-CT images produced a lower liver volume than the real CT images. SPECTCTAC exhibited a higher total count than SPECTNC and SPECTGAN, which were approximately 60% and 7% lower, respectively. The uniformities of SPECTCTAC and SPECTGAN were better than those of SPECTNC. The mean SSIM value for SPECTCTAC and SPECTGAN was 0.97. We proposed a deep learning-based AC approach to generate pseudo-CT images from SPECTNC images in 99mTc-GSA scintigraphy. SPECTGAN with AC using pseudo-CT images was similar to SPECTCTAC, demonstrating the possibility of SPECT/CT examination with reduced exposure to radiation.
Collapse
Affiliation(s)
- Masahiro Miyai
- Department of Radiological Technology, Graduate School of Health Sciences, Okayama University, 2-5-1 Shikata-Cho, Kita-Ku, Okayama-Shi, Okayama, 700-8558, Japan.
- Department of Radiology, Kawasaki Medical School General Medical Center, 2-6-1 Nakasange, Kita-Ku, Okayama-shi, Okayama, 700-8505, Japan.
| | - Ryohei Fukui
- Department of Radiological Technology, Faculty of Health Sciences, Okayama University, 2-5-1 Shikata-Cho, Kita-Ku, Okayama-shi, Okayama, 700-8558, Japan
| | - Masahiro Nakashima
- Division of Radiological Technology, Okayama University Hospital, 2-5-1 Shikata-Cho, Kita-Ku, Okayama-shi, Okayama, 700-8558, Japan
| | - Sachiko Goto
- Department of Radiological Technology, Faculty of Health Sciences, Okayama University, 2-5-1 Shikata-Cho, Kita-Ku, Okayama-shi, Okayama, 700-8558, Japan
| |
Collapse
|
29
|
de Nijs R, Berg RMG, Lindskov Hansen S, Mortensen J. Ventilation perfusion functional difference images in lung SPECT: A linear and symmetrical scale as an alternative to the ventilation perfusion ratio. Phys Med 2024; 119:103306. [PMID: 38335743 DOI: 10.1016/j.ejmp.2024.103306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 01/25/2024] [Accepted: 01/29/2024] [Indexed: 02/12/2024] Open
Abstract
PURPOSE Ventilation Perfusion SPECT is important in the diagnostics of e.g. pulmonary embolism and chronic obstructive pulmonary disease. Classical and reverse mismatched defects can be identified by utilizing the ventilation-perfusion ratio. Unfortunately, this ratio is only linear in the ventilation, the scale is not symmetrical regarding classical and reversed mismatches and small perfusion values give rise to artifacts. The ventilation-perfusion (VQ) difference is developed as an alternative. METHODS For both VQ-ratio and VQ-difference a scaling factor for the perfusion is computed, so that voxels with matched ventilation and perfusion (on average) yield zero signal. The relative VQ-difference is calculated by scaling with the summed VQ-signal in each voxel. The scaled VQ-difference is calculated by scaling with the global maximum of this sum. RESULTS The relative and scaled differences have a scale from -1 (perfusion only) to + 1 (ventilation only). Image quality of relative VQ-difference and VQ-ratio images is hampered by artifacts from areas with both low perfusion and low ventilation. Ratio and differences have been investigated in ten patients and are shown for three patients (one without defects). Clinical thresholds for the difference images are derived resulting in color maps of relevant (reversed) mismatches with a (reciprocal) ratio larger than two. CONCLUSIONS The relative ventilation-perfusion difference is a methodological improvement on the ventilation-perfusion ratio, because it has a symmetrical scale and is bound on a closed domain. A better diagnostic value is expected by utilizing the scaled difference, which represents functional difference instead of relative difference.
Collapse
Affiliation(s)
- Robin de Nijs
- Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark.
| | - Ronan M G Berg
- Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark; Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark; Center for Physical Activity Research, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark
| | - Sofie Lindskov Hansen
- Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark
| | - Jann Mortensen
- Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark; Department of Medicine, The National Hospital, Torshavn, Faroe Islands
| |
Collapse
|
30
|
Esteban Hurtado Á, Orozco Cortés J, Cárcamo Ibarra P, López González U, Badenes Romero Á, Navas de la Cruz MÁ, Siscar Gelo C, Casas Calabuig L, Abreu Sánchez P, Mut Dólera T, Balaguer Muñoz D, Reyes Ojeda MD, Plancha Mansanet C, Caballero Calabuig E. Concordance between freehand SPECT and conventional scintigraphy for sentinel lymph node detection in breast cancer. Rev Esp Med Nucl Imagen Mol 2024; 43:79-83. [PMID: 38387784 DOI: 10.1016/j.remnie.2024.02.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Accepted: 11/04/2023] [Indexed: 02/24/2024]
Abstract
INTRODUCTION Freehand SPECT can be a useful imaging technique for preoperative planning of sentinel lymph node biopsy (SLNB) as it allows localization of the sentinel node by 3D and real-time tomographic imaging and determines its depth after a few minutes of scanning. The aim of the study was to evaluate the correlation between the number of detected SNs between freehand SPECT images and lymphoscintigraphy (LS). MATERIALS AND METHODS 100 patients with a diagnosis of invasive breast cancer and no clinical evidence of lymph node involvement prospectively underwent SLNB. The preoperative study included freehand SPECT imaging at 15min after injection and LS imaging at 25 and 60-90min after injection (early and late). The observed agreement was analyzed and a concordance study was performed between the number of SNs detected with freehand SPECT and LS. RESULTS The observed agreement in the detection of SNs between freehand SPECT and early LS was 72%; between freehand SPECT and late LS was 85%; and between early and late LS was 87%. In the concordance study, there was moderate concordance between freehand SPECT and early LS (kappa coefficient: 0.42); moderate-high concordance between freehand SPECT and late LS (kappa coefficient: 0.60); and moderate-high concordance between early and late LS (kappa coefficient: 0.70), with no significant differences between them (p-value=0.16). CONCLUSION Freehand SPECT showed a moderate-high concordance with conventional imaging studies and could be a valid alternative for the presurgical study of SLNB in breast cancer.
Collapse
Affiliation(s)
- Á Esteban Hurtado
- Servicio de Medicina Nuclear, Hospital Universitario Doctor Peset, Valencia, Spain.
| | - J Orozco Cortés
- Servicio de Medicina Nuclear, Hospital Universitario Doctor Peset, Valencia, Spain
| | - P Cárcamo Ibarra
- Servicio de Medicina Nuclear, Hospital Clínico Universitario, Valencia, Spain
| | - U López González
- Servicio de Medicina Preventiva, Hospital Universitario Doctor Peset, Valencia, Spain
| | - Á Badenes Romero
- Servicio de Medicina Nuclear, Hospital Universitario Doctor Peset, Valencia, Spain
| | - M Á Navas de la Cruz
- Servicio de Medicina Nuclear, Hospital Universitario Doctor Peset, Valencia, Spain
| | - C Siscar Gelo
- Servicio de Medicina Nuclear, Hospital Universitario Doctor Peset, Valencia, Spain
| | - L Casas Calabuig
- Servicio de Medicina Nuclear, Hospital Universitario Doctor Peset, Valencia, Spain
| | - P Abreu Sánchez
- Servicio de Medicina Nuclear, Hospital Universitario Doctor Peset, Valencia, Spain
| | - T Mut Dólera
- Servicio de Medicina Nuclear, Hospital Universitario Doctor Peset, Valencia, Spain
| | - D Balaguer Muñoz
- Servicio de Medicina Nuclear, Hospital Universitario Doctor Peset, Valencia, Spain
| | - M D Reyes Ojeda
- Servicio de Medicina Nuclear, Hospital Universitario Doctor Peset, Valencia, Spain
| | - C Plancha Mansanet
- Servicio de Medicina Nuclear, Hospital Universitario Doctor Peset, Valencia, Spain
| | - E Caballero Calabuig
- Servicio de Medicina Nuclear, Hospital Universitario Doctor Peset, Valencia, Spain
| |
Collapse
|
31
|
Conrad TJ, Lau HX, Yerkovich ST, Alghamry A, Lee JC. Ventilation-perfusion scan for diagnosing pulmonary embolism: do chest x-rays matter? Nucl Med Commun 2024; 45:181-187. [PMID: 38247659 DOI: 10.1097/mnm.0000000000001802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2024]
Abstract
BACKGROUND Ventilation-perfusion (V/Q) scan coupled with single photon emission computed tomography (SPECT) is commonly used for the diagnosis of pulmonary embolism (PE). An abnormal chest x-ray (CXR) is deemed to hinder the interpretation of V/Q scan and therefore a normal CXR is recommended prior to V/Q scan. AIMS To determine if an abnormal CXR impacted on V/Q scan interpretation and subsequent management. METHODS A retrospective cohort analysis of all patients who underwent a V/Q scan for diagnosis of suspected acute PE between March 2016 and 2022 was performed. CXR reports were reviewed and classified as normal or abnormal. Low-dose computerised tomography was routinely performed in patients above the age of 70. Data regarding V/Q scan results and subsequent management including initiation of anticoagulation for PE or further diagnostic investigations were collected. RESULTS A total of 340 cases were evaluated. Of the positive V/Q scans (92/340), 98.3% of the normal CXR were anticoagulated compared to 100% of the abnormal CXR group. Of the negative V/Q scans (239/340), no cases were started on anticoagulation and no further investigations were performed across both normal and abnormal CXR groups. Indeterminate results occurred in only 9 cases with no significant difference in management between normal and abnormal CXR groups. CONCLUSION An abnormal CXR does not affect the reliability of V/Q scan interpretation in the diagnosis of PE when coupled with SPECT. Unless clinically indicated, the mandate by clinical society guidelines for a normal CXR prior to V/Q should be revisited.
Collapse
Affiliation(s)
- Thomas J Conrad
- Internal Medicine Services, The Prince Charles Hospital, Metro North Health, Brisbane
- Internal Medicine Services, Toowoomba Hospital, Darling Downs Health, Toowoomba, Queensland, Australia
| | - Han X Lau
- Internal Medicine Services, The Prince Charles Hospital, Metro North Health, Brisbane
| | - Stephanie T Yerkovich
- Child and Maternal Health Division, Menzies School of Health Research, Charles Darwin University, Darwin, Northern Territory, Australia
- Australian Centre for Health Services Innovation, Queensland University of Technology
| | - Alaa Alghamry
- Internal Medicine Services, The Prince Charles Hospital, Metro North Health, Brisbane
- Faculty of Medicine, The University of Queensland
| | - Joseph C Lee
- Faculty of Medicine, The University of Queensland
- Department of Medical Imaging, The Prince Charles Hospital, Metro North Health, Brisbane, Queensland, Australia
| |
Collapse
|
32
|
Nakashima M, Yamazaki Y. Evaluation of attenuation correction method for head holder in brain perfusion single-photon emission computed tomography. Radiol Phys Technol 2024; 17:322-328. [PMID: 38332240 DOI: 10.1007/s12194-024-00778-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2023] [Revised: 01/03/2024] [Accepted: 01/04/2024] [Indexed: 02/10/2024]
Abstract
Head holder attenuation affects brain perfusion single-photon emission computed tomography (SPECT) image quality. Here, we proposed a head holder-attenuation correction (AC) method using attenuation coefficient maps calculated by Chang's method from CT images. Then, we evaluated the effectiveness of the head holder-AC method by numerical phantom and clinical cerebral perfusion SPECT studies. In the numerical phantom, the posterior counts were 10.7% lower than the anterior counts without head holder-AC method. However, by performing head holder-AC, the posterior count recovered by approximately 6.8%, approaching the true value. In the clinical study, the normalized count ratio was significantly increased by performing the head holder-AC method in the posterior-middle cerebral artery, posterior cerebral artery and cerebellum regions. There were no significant increases in other regions. The head holder-AC method can correct the counts attenuated by the head holder.
Collapse
Affiliation(s)
- Masahiro Nakashima
- Division of Radiological Technology, Okayama University Hospital, 2-5-1 Shikatacho, Kitaku, Okayama, 700-8558, Japan.
| | - Yuta Yamazaki
- Canon Medical Systems Corporation, 1385 Shimoishigami, Otawara-Shi, Tochigi, 324-8550, Japan
| |
Collapse
|
33
|
Shibutani T, Onoguchi M, Kanno T, Kinuya S. Influence of spill-over for 99mTc images and the effect of scatter correction for dual-isotope simultaneous acquisition with 99mTc and 18F using small-animal SPECT-PET/CT system. Phys Eng Sci Med 2024; 47:135-142. [PMID: 37902935 DOI: 10.1007/s13246-023-01348-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Accepted: 10/16/2023] [Indexed: 11/01/2023]
Abstract
A dual-isotope simultaneous acquisition (DISA) of 99mTc and 18F affects the image quality of 99mTc by crosstalk and spill-over from 18F. We demonstrated the influence of spill-over and crosstalk on image quality and its correction effect for DISA SPECT with 99mTc and 18F. A fillable cylindrical chamber of 30 mm with NEMA-NU4 image quality phantom was filled with 99mTc only or a mixed 99mTc and 18F solution (C100). Two small-region chambers were filled with 99mTc only or a mixed 99mTc and 18F solution made at half the radioactivity concentration of C100 (C50) and non-radioactive water (C0). The 18F/99mTc ratio for DISA was set at approximately 0.4-12. Two types of 99mTc transverse images with and without scatter correction (SC and nonSC) were created. The 99mTc images of single-isotope acquisition (SIA) were created as a reference. The DISA/SIA ratio and contrast of 99mTc were compared between SIA and DISA. Although the DISA/SIA ratios with nonSC of C100, C50 and C0 gradually increased with increasing 18F/99mTc ratio, it was nearly constant by SC. The contrasts of C100 and C50 were similar to a reference value for both nonSC and SC. In conclusion, DISA images showed lower image quality as the 18F/99mTc ratio increased. The image quality in hot-spot regions such as C100 and C50 was improved by SC, whereas cold-spot regions such as C0 could not completely remove the influence of spill-over even with SC.
Collapse
Affiliation(s)
- Takayuki Shibutani
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
| | - Masahisa Onoguchi
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan.
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan.
| | - Takayuki Kanno
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
- Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan
- Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
| | - Seigo Kinuya
- Department of Nuclear Medicine, Kanazawa University Hospital, Kanazawa, Japan
| |
Collapse
|
34
|
Noipinit N, Sukprakun C, Siricharoen P, Khamwan K. Comparison of absorbed doses to the tumoral and non-tumoral liver in HCC patients undergoing 99mTc-MAA and 90Y-microspheres radioembolization. Ann Nucl Med 2024; 38:210-218. [PMID: 38142421 DOI: 10.1007/s12149-023-01890-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 11/26/2023] [Indexed: 12/26/2023]
Abstract
PURPOSE This study aimed to determine the absorbed doses in the tumoral-liver and non-tumoral liver of hepatocellular carcinoma (HCC) patients undergoing radioembolization with Yttrium-90 (90Y) resin microspheres, and compared with those derived from 99mTc-MAA using the partition model. METHODS A total of 42 HCC patients (28 males and 14 females, mean age 65 ± 11.51 years) who received 45 treatment sessions with 90Y-microspheres between 2016 and 2021 were included. Pre-treatment 99mTc-MAA and post-treatment 90Y-bremsstrahlung SPECT/CT were acquired for each patient. Semi-automated segmentation of regions of interest (ROIs) was performed using MIM Encore software to determine the tumor-liver ratio (TLR) encompassing the liver volume, tumoral-liver, and lungs, and verified by both nuclear medicine physician and interventional radiologist. A partition dosimetry model was used to estimate the administered activity of 90Y-microspheres and the absorbed doses to the tumoral-liver and non-tumoral liver. The student's paired t test and Bland-Altman plot were used for the statistical analysis. RESULTS The mean TLR values obtained from 99mTc-MAA SPECT/CT and 90Y-bremsstrahlung SPECT/CT were 4.78 ± 3.51 and 2.73 ± 1.18, respectively. The mean planning administered activity of 90Y-microspheres based on 99mTc-MAA SPECT/CT was 1.56 ± 0.80 GBq, while the implanted administered activity was 2.53 ± 1.23 GBq (p value < 0.001). The mean absorbed doses in the tumoral-liver estimated from 99mTc-MAA and 90Y-bremsstrahlung SPECT/CT were 127.44 ± 4.36 Gy and 135.98 ± 6.30 Gy, respectively. The corresponding mean absorbed doses in the non-tumoral liver were 34.61 ± 13.93 Gy and 55.04 ± 16.36 Gy. CONCLUSION This study provides evidence that the administered activity of 90Y-microspheres, as estimated from 90Y-bremsstrahlung SPECT/CT, was significantly higher than that estimated from 99mTc-MAA SPECT/CT resulted in increased absorbed doses in both the tumoral-liver and non-tumoral liver. However, 99mTc-MAA SPECT/CT remains a valuable planning tool for predicting the distribution of 90Y-microspheres in liver cancer treatment.
Collapse
Affiliation(s)
- Nut Noipinit
- Medical Physics Program, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
- Division of Nuclear Medicine, Department of Radiology, King Chulalongkorn Memorial Hospital, The Thai Red Cross Society, Bangkok, Thailand
- Chulalongkorn University Biomedical Imaging Group, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Chanan Sukprakun
- Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| | - Punnarai Siricharoen
- Department of Computer Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
| | - Kitiwat Khamwan
- Medical Physics Program, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
- Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
- Chulalongkorn University Biomedical Imaging Group, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
| |
Collapse
|
35
|
Lughezzani G, Casale P, Evangelista L. Re: Giuseppe Basile, Giuseppe Fallara, Paolo Verri, et al. The Role of 99mTc-Sestamibi Single-photon Emission Computed Tomography/Computed Tomography in the Diagnostic Pathway for Renal Masses: A Systematic Review and Meta-analysis. Eur Urol. 2024;85:63-71. Eur Urol 2024; 85:e76. [PMID: 38092612 DOI: 10.1016/j.eururo.2023.11.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Accepted: 11/09/2023] [Indexed: 03/09/2024]
Affiliation(s)
- Giovanni Lughezzani
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Italy; Department of Urology, IRCCS Humanitas Research Hospital, Rozzano, Italy.
| | - Paolo Casale
- Department of Urology, IRCCS Humanitas Research Hospital, Rozzano, Italy
| | - Laura Evangelista
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Italy; Department of Nuclear Medicine, IRCCS Humanitas Research Hospital, Rozzano, Italy
| |
Collapse
|
36
|
Di Carli MF. Navigating the positron emission tomography vs. single-photon emission computed tomography debate: A closer look at evidence and guidelines. J Nucl Cardiol 2024; 33:101822. [PMID: 38369407 DOI: 10.1016/j.nuclcard.2024.101822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2024] [Accepted: 01/28/2024] [Indexed: 02/20/2024]
Affiliation(s)
- Marcelo F Di Carli
- Cardiovascular Imaging Program, Departments of Radiology and Medicine, USA; Division of Nuclear Medicine and Cardiovascular Imaging, Department of Radiology, USA; Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, USA.
| |
Collapse
|
37
|
Nakata T, Shimada K, Iba A, Oda H, Terashima A, Koide Y, Kawasaki R, Yamada T, Ishii K. Differential diagnosis of MCI with Lewy bodies and MCI due to Alzheimer's disease by visual assessment of occipital hypoperfusion on SPECT images. Jpn J Radiol 2024; 42:308-318. [PMID: 37861956 DOI: 10.1007/s11604-023-01501-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Accepted: 09/27/2023] [Indexed: 10/21/2023]
Abstract
PURPOSE Predicting progression of mild cognitive impairment (MCI) to Alzheimer's disease (AD) or dementia with Lewy bodies (DLB) is important. We evaluated morphological and functional differences between MCI with Lewy bodies (MCI-LB) and MCI due to AD (MCI-AD), and a method for differentiating between these conditions using brain MRI and brain perfusion SPECT. METHODS A continuous series of 101 subjects, who had visited our memory clinic and met the definition of MCI, were enrolled retrospectively. They were consisted of 60 MCI-LB and 41 MCI-AD subjects. Relative cerebral blood flow (rCBF) on SPECT images and relative brain atrophy on MRI images were evaluated. We performed voxel-based analysis and visually inspected brain perfusion SPECT images for regional brain atrophy, occipital hypoperfusion and the cingulate island sign (CIS), for differential diagnosis of MCI-LB and MCI-AD. RESULTS MRI showed no significant differences in regional atrophy between the MCI-LB and MCI-AD groups. In MCI-LB subjects, occipital rCBF was significantly decreased compared with MCI-AD subjects (p < 0.01, family wise error [FWE]-corrected). Visual inspection of occipital hypoperfusion had sensitivity, specificity, and accuracy values of 100%, 73.2% and 89.1%, respectively, for differentiating MCI-LB and MCI-AD. Occipital hypoperfusion was offered higher diagnostic utility than the CIS. CONCLUSIONS The occipital lobe was the region with significantly decreased rCBF in MCI-LB compared with MCI-AD subjects. Occipital hypoperfusion on brain perfusion SPECT may be a more useful imaging biomarker than the CIS for visually differentiating MCI-LB and MCI-AD.
Collapse
Affiliation(s)
- Takashi Nakata
- Neurocognitive Disorders Medical Center, Hyogo Prefectural Harima-Himeji General Medical Center, 3-264 Kamiyacho, Himeji, Hyogo, 670-8560, Japan.
- Department of Radiology, Kindai University Faculty of Medicine, 377-2 Ohnohigashi, Osakasayama, Osaka, Japan.
- Department of Aging Brain and Cognitive Disorders, Hyogo Brain and Heart Center, 520 Saisho-Ko, Himji, Hyogo, Japan.
| | - Kenichi Shimada
- Neurocognitive Disorders Medical Center, Hyogo Prefectural Harima-Himeji General Medical Center, 3-264 Kamiyacho, Himeji, Hyogo, 670-8560, Japan
- Department of Aging Brain and Cognitive Disorders, Hyogo Brain and Heart Center, 520 Saisho-Ko, Himji, Hyogo, Japan
| | - Akiko Iba
- Department of Aging Brain and Cognitive Disorders, Hyogo Brain and Heart Center, 520 Saisho-Ko, Himji, Hyogo, Japan
- Department of Psychiatry, Hyogo Prefectural Harima-Himeji General Medical Center, 3-264 Kamiyacho, Himeji, Hyogo, Japan
- Hyogo Mental Health Center, 3 Noborio, Kamitanigami, Yamadacho, Kita-Ku, Kobe, Hyogo, Japan
| | - Haruhiko Oda
- Neurocognitive Disorders Medical Center, Hyogo Prefectural Harima-Himeji General Medical Center, 3-264 Kamiyacho, Himeji, Hyogo, 670-8560, Japan
- Department of Aging Brain and Cognitive Disorders, Hyogo Brain and Heart Center, 520 Saisho-Ko, Himji, Hyogo, Japan
- Hyogo Mental Health Center, 3 Noborio, Kamitanigami, Yamadacho, Kita-Ku, Kobe, Hyogo, Japan
| | - Akira Terashima
- Neurocognitive Disorders Medical Center, Hyogo Prefectural Harima-Himeji General Medical Center, 3-264 Kamiyacho, Himeji, Hyogo, 670-8560, Japan
- Department of Aging Brain and Cognitive Disorders, Hyogo Brain and Heart Center, 520 Saisho-Ko, Himji, Hyogo, Japan
| | - Yutaka Koide
- Department of Diagnostic and Interventional Radiology, Hyogo Prefectural Harima-Himeji General Medical Center, 3-264 Kamiyacho, Himeji, Hyogo, Japan
- Department of Radiology and Nuclear Medicine, Hyogo Brain and Heart Center, 520 Saisho-Ko, Himeji, Hyogo, Japan
| | - Ryota Kawasaki
- Department of Diagnostic and Interventional Radiology, Hyogo Prefectural Harima-Himeji General Medical Center, 3-264 Kamiyacho, Himeji, Hyogo, Japan
- Department of Radiology and Nuclear Medicine, Hyogo Brain and Heart Center, 520 Saisho-Ko, Himeji, Hyogo, Japan
| | - Takahiro Yamada
- Department of Radiology, Kindai University Faculty of Medicine, 377-2 Ohnohigashi, Osakasayama, Osaka, Japan
| | - Kazunari Ishii
- Department of Radiology, Kindai University Faculty of Medicine, 377-2 Ohnohigashi, Osakasayama, Osaka, Japan
- Department of Diagnostic and Interventional Radiology, Hyogo Prefectural Harima-Himeji General Medical Center, 3-264 Kamiyacho, Himeji, Hyogo, Japan
- Department of Radiology and Nuclear Medicine, Hyogo Brain and Heart Center, 520 Saisho-Ko, Himeji, Hyogo, Japan
| |
Collapse
|
38
|
Buchert R, Szabo B, Kovacs A, Buddenkotte T, Mathies F, Karimzadeh A, Lehnert W, Klutmann S, Forgacs A, Apostolova I. Dopamine Transporter SPECT with 12-Minute Scan Duration Using Multiple-Pinhole Collimators. J Nucl Med 2024; 65:446-452. [PMID: 38238040 DOI: 10.2967/jnumed.123.266276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Accepted: 11/28/2023] [Indexed: 03/03/2024] Open
Abstract
This study evaluated the potential to reduce the scan duration in dopamine transporter (DAT) SPECT when using a second-generation multiple-pinhole (MPH) collimator designed for brain SPECT with improved count sensitivity and improved spatial resolution compared with parallel-hole and fanbeam collimators. Methods: The retrospective study included 640 consecutive clinical DAT SPECT studies that had been acquired in list mode with a triple-head SPECT system with MPH collimators and a 30-min net scan duration after injection of 181 ± 10 MBq of [123I]FP-CIT. Raw data corresponding to scan durations of 20, 15, 12, 8, 6, and 4 min were obtained by restricting the events to a proportionally reduced time interval of the list-mode data for each projection angle. SPECT images were reconstructed iteratively with the same parameter settings irrespective of scan duration. The resulting 5,120 SPECT images were assessed for a neurodegeneration-typical reduction in striatal signal by visual assessment, conventional specific binding ratio analysis, and a deep convolutional neural network trained on 30-min scans. Results: Regarding visual interpretation, image quality was considered diagnostic for all 640 patients down to a 12-min scan duration. The proportion of discrepant visual interpretations between 30 and 12 min (1.2%) was not larger than the proportion of discrepant visual interpretations between 2 reading sessions of the same reader at a 30-min scan duration (1.5%). Agreement with the putamen specific binding ratio from the 30-min images was better than expected for 5% test-retest variability down to a 10-min scan duration. A relevant change in convolutional neural network-based automatic classification was observed at a 6-min scan duration or less. Conclusion: The triple-head SPECT system with MPH collimators allows reliable DAT SPECT after administration of about 180 MBq of [123I]FP-CIT with a 12-min scan duration.
Collapse
Affiliation(s)
- Ralph Buchert
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; and
| | - Balazs Szabo
- Mediso Medical Imaging Systems, Budapest, Hungary
| | - Akos Kovacs
- Mediso Medical Imaging Systems, Budapest, Hungary
| | - Thomas Buddenkotte
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; and
| | - Franziska Mathies
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; and
| | - Amir Karimzadeh
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; and
| | - Wencke Lehnert
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; and
| | - Susanne Klutmann
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; and
| | | | - Ivayla Apostolova
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; and
| |
Collapse
|
39
|
Kawakubo M, Nagao M, Kaimoto Y, Nakao R, Yamamoto A, Kawasaki H, Iwaguchi T, Matsuo Y, Kaneko K, Sakai A, Sakai S. Deep learning approach using SPECT-to-PET translation for attenuation correction in CT-less myocardial perfusion SPECT imaging. Ann Nucl Med 2024; 38:199-209. [PMID: 38151588 PMCID: PMC10884131 DOI: 10.1007/s12149-023-01889-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Accepted: 11/23/2023] [Indexed: 12/29/2023]
Abstract
OBJECTIVE Deep learning approaches have attracted attention for improving the scoring accuracy in computed tomography-less single photon emission computed tomography (SPECT). In this study, we proposed a novel deep learning approach referring to positron emission tomography (PET). The aims of this study were to analyze the agreement of representative voxel values and perfusion scores of SPECT-to-PET translation model-generated SPECT (SPECTSPT) against PET in 17 segments according to the American Heart Association (AHA). METHODS This retrospective study evaluated the patient-to-patient stress, resting SPECT, and PET datasets of 71 patients. The SPECTSPT generation model was trained (stress: 979 image pairs, rest: 987 image pairs) and validated (stress: 421 image pairs, rest: 425 image pairs) using 31 cases of SPECT and PET image pairs using an image-to-image translation network. Forty of 71 cases of left ventricular base-to-apex short-axis images were translated to SPECTSPT in the stress and resting state (stress: 1830 images, rest: 1856 images). Representative voxel values of SPECT and SPECTSPT in the 17 AHA segments against PET were compared. The stress, resting, and difference scores of 40 cases of SPECT and SPECTSPT were also compared in each of the 17 segments. RESULTS For AHA 17-segment-wise analysis, stressed SPECT but not SPECTSPT voxel values showed significant error from PET at basal anterior regions (segments #1, #6), and at mid inferoseptal regions (segments #8, #9, and #10). SPECT, but not SPECTSPT, voxel values at resting state showed significant error at basal anterior regions (segments #1, #2, and #6), and at mid inferior regions (segments #8, #9, and #11). Significant SPECT overscoring was observed against PET in basal-to-apical inferior regions (segments #4, #10, and #15) during stress. No significant overscoring was observed in SPECTSPT at stress, and only moderate over and underscoring in the basal inferior region (segment #4) was found in the resting and difference states. CONCLUSIONS Our PET-supervised deep learning model is a new approach to correct well-known inferior wall attenuation in SPECT myocardial perfusion imaging. As standalone SPECT systems are used worldwide, the SPECTSPT generation model may be applied as a low-cost and practical clinical tool that provides powerful auxiliary information for the diagnosis of myocardial blood flow.
Collapse
Affiliation(s)
- Masateru Kawakubo
- Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Michinobu Nagao
- Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
| | - Yoko Kaimoto
- Department of Radiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Risako Nakao
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Atsushi Yamamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Hiroshi Kawasaki
- Department of Advanced Information Technology, Faculty of Information Science and Electrical Engineering, Kyushu University, Fukuoka, Japan
| | - Takafumi Iwaguchi
- Department of Advanced Information Technology, Faculty of Information Science and Electrical Engineering, Kyushu University, Fukuoka, Japan
| | - Yuka Matsuo
- Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan
| | - Koichiro Kaneko
- Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan
| | - Akiko Sakai
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Shuji Sakai
- Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan
| |
Collapse
|
40
|
Villines TC, Rodriguez-Lozano P, Mallawaarachchi I, Williams MC, Hirschfeld C, Better N, Shaw LJ, Vitola JV, Cerci RJ, Dorbala S, Bucciarelli-Ducci C, Karthikeyan G, Cohen YA, Malkovskiy E, Randazzo MJ, Choi AD, Pascual TNB, Pynda Y, Dondi M, Paez D, Einstein AJ. Disparities in Noninvasive Traditional and Advanced Testing for Coronary Artery Disease: Findings from the INCAPS-COVID 2 Study. Am J Cardiol 2024; 214:85-93. [PMID: 38218393 DOI: 10.1016/j.amjcard.2023.12.048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 12/10/2023] [Accepted: 12/24/2023] [Indexed: 01/15/2024]
Abstract
The COVID-19 pandemic disrupted the delivery of cardiovascular care, including noninvasive testing protocols and test selection for the evaluation of coronary artery disease (CAD). Trends in test selection in traditional versus advanced noninvasive tests for CAD during the pandemic and in countries of varying income status have not been well studied. The International Atomic Energy Agency conducted a global survey to assess the pandemic-related changes in the practice of cardiovascular diagnostic testing. Site procedural volumes for noninvasive tests to evaluate CAD from March 2019 (prepandemic), April 2020 (onset), and April 2021 (initial recovery) were collected. We considered traditional testing modalities, such as exercise electrocardiography, stress echocardiography, and stress single-photon emission computed tomography, and advanced testing modalities, such as stress cardiac magnetic resonance, coronary computed tomography angiography, and stress positron emission tomography. Survey data were obtained from 669 centers in 107 countries, reporting the performance of 367,933 studies for CAD during the study period. Compared with 2019, traditional tests were performed 14% less frequently (recovery rate 82%) in 2021 versus advanced tests, which were performed 15% more frequently (128% recovery rate). Coronary computed tomography angiography, stress cardiac magnetic resonance, and stress positron emission tomography showed 14%, 25%, and 25% increases in volumes from 2019 to 2021, respectively. The increase in advanced testing was isolated to high- and upper middle-income countries, with 132% recovery in advanced tests by 2021 compared with 55% in lower income nations. The COVID-19 pandemic exacerbated economic disparities in CAD testing practice between wealthy and poorer countries. Greater recovery rates and even new growth were observed for advanced imaging modalities; however, this growth was restricted to wealthy countries. Efforts to reduce practice variations in CAD testing because of economic status are warranted.
Collapse
Affiliation(s)
- Todd C Villines
- University of Virginia Health System, Charlottesville, Virginia.
| | | | | | - Michelle C Williams
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| | - Cole Hirschfeld
- Division of Cardiology, Weill Cornell Medicine and NewYork-Presbyterian Hospital, New York, New York
| | - Nathan Better
- Department of Cardiology and Nuclear Medicine, Cabrini Health, Royal Melbourne Hospital, University of Melbourne, Australia
| | - Leslee J Shaw
- Blavatnik Family Women'S Health Research Institute, Mount Sinai Medical Center, New York, New York
| | | | | | | | - Chiara Bucciarelli-Ducci
- Royal Brompton and Harefield Hospitals, Guys' and St Thomas NHS Trust and King's College London, London, United Kingdom
| | - Ganesan Karthikeyan
- Department of Cardiology, All India Institute of Medical Sciences, New Delhi, India
| | - Yosef A Cohen
- Department of Epidimiology, Columbia-Mailman School of Public Health, New York, New York
| | - Eli Malkovskiy
- Seymour, Paul and Gloria Milstein Division of Cardiology, Department of Medicine, Columbia University Irving Medical Center and NewYork-Presbyterian Hospital, New York, New York; Department of Medicine, Columbia University Irving Medical Center and New York-Presbyterian Hospital, New York, New York
| | - Michael J Randazzo
- Section of Cardiology, University of Chicago Medical Center, Chicago, Illinois
| | - Andrew D Choi
- Division of Cardiology and Department of Radiology, The George Washington University School of Medicine, Washington, District of Columbia
| | | | - Yaroslav Pynda
- Division of Human Health, Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Vienna, Austria
| | - Maurizio Dondi
- Division of Human Health, Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Vienna, Austria
| | - Diana Paez
- Division of Human Health, Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Vienna, Austria
| | - Andrew J Einstein
- Seymour, Paul and Gloria Milstein Division of Cardiology, Department of Medicine, Columbia University Irving Medical Center and NewYork-Presbyterian Hospital, New York, New York; Department of Medicine, Columbia University Irving Medical Center and New York-Presbyterian Hospital, New York, New York
| |
Collapse
|
41
|
Leblanc M, Tessier M, Ollenberger G, O'Brien C, Zuckier LS. Guidelines for ventilation/perfusion (V/P SPECT) in pulmonary embolism. J Med Imaging Radiat Sci 2024; 55:158-162. [PMID: 37996383 DOI: 10.1016/j.jmir.2023.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Accepted: 09/07/2023] [Indexed: 11/25/2023]
|
42
|
Salgado-Garcia C, Moreno-Ballesteros A, Guardia-Jimena P, Sanchez-de-Mora E, Rebollo-Aguirre AC, Ramirez-Navarro A, Santos-Bueno A, Jimenez-Heffernan A. Role of the clinical radiopharmacist in patient safety during myocardial perfusion imaging with vasodilator stress agents. Rev Esp Med Nucl Imagen Mol 2024; 43:84-90. [PMID: 38184070 DOI: 10.1016/j.remnie.2023.12.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 11/20/2023] [Accepted: 11/23/2023] [Indexed: 01/08/2024]
Abstract
AIM To assess the radiopharmacist's role in a multidisciplinary team focused on the contraindications of regadenoson in order to ensure the safe use of pharmacologic vasodilator stress agents in patients undergoing SPECT-MPI. METHODS We ambispectively studied its safe use in 1905 patients (54.1% female, mean age: 66.6±11.7 years, range: 20-95 years). Sex, age, medical history, medications, drug allergies, and contraindications for stress testing were registered together with recommendations for the nuclear physician in charge. RESULTS Detected contraindications and corresponding recommendations were as follows: risk factors for QTc interval prolongation 7.5% - measurement of QTc interval previously to test and monitor ECG; prior stroke or TIA 4.2% - consider carotid stenosis assessment; salicylates/sulfonamides allergy 3.1% - use 99mTc-sestamibi; epilepsy or risk factors for seizures 2.4% - use of adenosine or reconsider test indication; systemic corticosteroid therapy for severe COPD 1.3% - reassessment of patient's condition; acute exacerbation of COPD 0.8% - defer test until acute episode is over; severe asthma 0.4% - do not perform test; methylxanthine ingestion 0.3% - avoid consumption previously; other 6.1% - evaluation of other contraindications. No contraindications were detected in 73.6% of patients. The test was canceled due to absolute contraindications in 2.9% of the requests. CONCLUSIONS Working in a systematic way, the radiopharmacist was able to detect a high number of issues related to regadenoson, with one out of four patients presenting some clinical contraindication. The recommendations given by the radiopharmacist were well accepted by the nuclear physicians who changed their approach contributing to increase the safety of patients referred for MPI.
Collapse
Affiliation(s)
- C Salgado-Garcia
- Radiopharmacy Unit (Department of Nuclear Medicine), Hospital Juan Ramon Jimenez, Huelva, Spain.
| | | | - P Guardia-Jimena
- Department of Nuclear Medicine, Hospital Juan Ramon Jimenez, Huelva, Spain
| | - E Sanchez-de-Mora
- Department of Nuclear Medicine, Hospital Juan Ramon Jimenez, Huelva, Spain
| | | | - A Ramirez-Navarro
- Radiopharmacy Unit (Department of Nuclear Medicine), Hospital Virgen de las Nieves, Granada, Spain
| | - A Santos-Bueno
- Department of Nuclear Medicine, Hospital Juan Ramon Jimenez, Huelva, Spain
| | | |
Collapse
|
43
|
Li T, Dou J, Zhang H, Su X, Liu Y, Gao M, Xiao J, Xu W, Gao J. Optimized gated a SPECT-derived myocardial salvage index: its prognostic significance in predicting major adverse cardiac events following acute myocardial infarction percussion. Ann Nucl Med 2024; 38:219-230. [PMID: 38175381 DOI: 10.1007/s12149-023-01894-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Accepted: 11/26/2023] [Indexed: 01/05/2024]
Abstract
PURPOSE Estimate myocardial salvage index (MSI) using a single-gated Single-Photon Emission Computed Tomography (SPECT) myocardial perfusion imaging (GSMPI) early after percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI) and compare its predictive value with the traditional method especially for post-PCI left ventricular ejection fraction (LVEF) improvement and major adverse cardiac events (MACEs). METHODS GSMPI was performed in 62 patients with AMI early after PCI (3-10 days). The MSI and the conventional parameters were obtained, including total perfusion deficit, LVEF, peak ejection rate (PER), and peak filling rate (PFR). The new calculation method (scoring evaluation method means the extent of abnormality is the percentage of the total scores of abnormal segments divided by the sum of the maximum scores of all myocardial segments using 4-point and 5-point scale semi-quantitative scoring method) and the reference method (number evaluation method means the extent of abnormality is the percentage of the number of abnormal segments divided by the total number of myocardial segments) were applied to acquire the MSI. We compared the predictive ability of the 2 methods based on the area under the receiver operating characteristic curve for LVEF improvement 6 months after PCI using MSI. The Kaplan-Meier method was used for depicting survival curves for predicting MACEs by the 2 methods. Cox proportional-hazards regression was applied to confirm the independent predictors of MACEs. RESULTS The MSI obtained by the new method indicated stronger prognostic significance in LVEF improvement [area under the curve (AUC): 0.793, 95% confidence interval (CI) 0.620-0.912, P < .001] compared with the reference method (AUC: 0.634, 95%CI 0.452-0.792, P = .187). Delong's test revealed a statistically significant difference in AUCs between the 2 methods (P < .05, 95%CI 0.003-0.316). The diagnostic value of the scoring evaluation method was higher than that of the number evaluation method. The Cox prevalence of MACEs was substantially higher in the < median MSI group than in the ≥ median MSI group (hazard ratio: 0.172; 95% CI 0.041-0.724; P < .05] using the new method, whereas no considerable differences were observed between the 2 groups using the reference method (P = .12). Further, the multivariate Cox regression analysis revealed that MSI was an independent indicator for predicting MACEs (P < .05). CONCLUSION The MSI obtained from a simple GSMPI early after PCI, using the scoring evaluation method, was a reliable prognostic indicator for predicting LVEF improvement and MACEs in AMI. It remarkably improved the prognostic value compared with the previous reference methods.
Collapse
Affiliation(s)
- Ting Li
- Department of Molecular Imaging and Nuclear Medicine, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, The Huan-Hu-Xi Road, Ti-Yuan-Bei, HeXi District, Tianjin, 300060, People's Republic of China
- Department of Nuclear Medicine, Tianjin Chest Hospital, No. 261 Tai Er Zhuang Road, Jinnan District, Tianjin, 300222, People's Republic of China
- Graduate School, Tianjin Medical University, No. 22 Qi Xiang Tai Road, Heping District, Tianjin, 300070, People's Republic of China
| | - Jing Dou
- Department of Cardiology, Tianjin Chest Hospital, No. 261 Tai Er Zhuang Road, Jinnan District, Tianjin, 300222, People's Republic of China
| | - Hong Zhang
- Department of Radiology, Tianjin Chest Hospital, No. 261 Tai Er Zhuang Road, Jinnan District, Tianjin, 300222, People's Republic of China
| | - Xuexiao Su
- Department of Nuclear Medicine, Tianjin Chest Hospital, No. 261 Tai Er Zhuang Road, Jinnan District, Tianjin, 300222, People's Republic of China
| | - Yin Liu
- Department of Cardiology, Tianjin Chest Hospital, No. 261 Tai Er Zhuang Road, Jinnan District, Tianjin, 300222, People's Republic of China
| | - Mingdong Gao
- Department of Cardiology, Tianjin Chest Hospital, No. 261 Tai Er Zhuang Road, Jinnan District, Tianjin, 300222, People's Republic of China
| | - Jianyong Xiao
- Department of Cardiology, Tianjin Chest Hospital, No. 261 Tai Er Zhuang Road, Jinnan District, Tianjin, 300222, People's Republic of China
| | - Wengui Xu
- Department of Molecular Imaging and Nuclear Medicine, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, The Huan-Hu-Xi Road, Ti-Yuan-Bei, HeXi District, Tianjin, 300060, People's Republic of China.
| | - Jing Gao
- Cardiovascular Institute, Tianjin Chest Hospital, No. 261 Tai Er Zhuang Road, Jinnan District, Tianjin, 300222, People's Republic of China.
- Thoracic Clinical College, Tianjin Medical University, No. 22 Qi Xiang Tai Road, Heping District, Tianjin, 300070, People's Republic of China.
| |
Collapse
|
44
|
Al Rifai M, Winchester D. When should myocardial perfusion imaging be a first-test choice? J Nucl Cardiol 2024; 33:101824. [PMID: 38360263 DOI: 10.1016/j.nuclcard.2024.101824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 02/05/2024] [Accepted: 02/06/2024] [Indexed: 02/17/2024]
Affiliation(s)
- Mahmoud Al Rifai
- Houston Methodist DeBakey Heart & Vascular Center, Houston, TX, USA
| | - David Winchester
- Division of Cardiovascular Medicine, University of Florida, Gainesville, FL, USA.
| |
Collapse
|
45
|
Chong A, Seo Y, Bang JI, Park S, Kim K, Hong CM, Choi M, Oh SW, Lee SW. Clinical Implications of Adding SPECT/CT to Radioiodine Whole-Body Scan in Patients With Differentiated Thyroid Cancer: A Systematic Review and Meta-analysis. Clin Nucl Med 2024; 49:215-225. [PMID: 38048517 DOI: 10.1097/rlu.0000000000004953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/06/2023]
Abstract
PURPOSE This study aimed to determine the usefulness of adding SPECT/CT to radioiodine whole-body scans (WBSs) for the treatment of differentiated thyroid cancer (DTC). PATIENTS AND METHODS A systematic review and meta-analysis were performed following the PRISMA guidelines (PROSPERO registration: CRD42022341732) to compare the feasibility of conclusive readings and the frequency of changes in treatment plans in patients with DTC undergoing WBS + SPECT/CT versus WBS. MEDLINE, EMBASE, and Cochrane databases were searched to identify relevant articles concerning thyroid cancer, radioactive iodine, and SPECT/CT or SPECT, published before August 16, 2023. Studies not comparing WBS + SPECT/CT with WBS, those lacking target outcomes, and those not involving human subjects were excluded. The risk of bias was assessed using the RoBANS 2.0 (Risk of Bias Assessment Tool for Nonrandomized Studies) tool. The GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) system was used to evaluate the quality of evidence and strength of recommendations. RESULTS A total of 30 studies (prospective n = 9, retrospective n = 21) were included in the meta-analyses. Adding SPECT/CT to WBS was shown to increase conclusive readings for cervical lesions, extracervical lesions, and all regions. Lesion-based analyses showed improvements of 14%, 20%, and 18%, respectively, whereas scan-based analyses showed improvements of 27%, 9%, and 34%. The addition of SPECT/CT to WBS led to changes in 30% of treatment plans after diagnostic scans and 9% of treatment plans after posttherapeutic scans. The quality of evidence and strength of recommendations were low. CONCLUSIONS Compelling evidence demonstrates that the addition of SPECT/CT to WBS improves lesion localization, diagnostic performance, and therapy plan for patients with DTC.
Collapse
Affiliation(s)
- Ari Chong
- From the Department of Nuclear Medicine, Chosun University, College of Medicine and Chosun University Hospital, Gwangju
| | - Youngduk Seo
- Department of Nuclear Medicine, Chungnam National University Sejong Hospital, Sejong
| | - Ji-In Bang
- Department of Nuclear Medicine, CHA Bundang Medical Center, CHA University, Pocheon
| | - Sohyun Park
- Department of Nuclear Medicine, Hospital, National Cancer Center, Goyang
| | - Keunyoung Kim
- Department of Nuclear Medicine and Biomedical Research Institute, Pusan National University Hospital and School of Medicine, Pusan National University, Busan
| | - Chae Moon Hong
- Department of Nuclear Medicine, School of Medicine, Kyungpook National University, Daegu
| | - Miyoung Choi
- Division of Health Technology Assessment Research, National Evidence-Based Healthcare Collaborating Agency
| | - So Won Oh
- Department of Nuclear Medicine, Seoul National University Boramae Medical Center, Seoul
| | - Sang-Woo Lee
- Department of Nuclear Medicine, Kyungpook National University, School of Medicine and Chilgok Hospital, Daegu, South Korea
| |
Collapse
|
46
|
Ma R, Ji C, Shen M, Xu S, Fan G, Wu C, Yu Q, Yin L. Development of Small HN Linked Radionuclide Iodine-125 for Nanocarrier Image Tracing in Mouse Model. Int J Nanomedicine 2024; 19:1909-1922. [PMID: 38414522 PMCID: PMC10898482 DOI: 10.2147/ijn.s446564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Accepted: 02/15/2024] [Indexed: 02/29/2024] Open
Abstract
Background Radionuclides have important roles in clinical tumor radiotherapy as they are used to kill tumor cells or as imaging agents for drug tracing. The application of radionuclides has been developing as an increasing number of nanomaterials are used to deliver radionuclides to tumor areas to kill tumor cells. However, promoting the efficient combination of radionuclides and nanocarriers (NCs), enhancing radionuclide loading efficiency, and avoiding environmental pollution caused by radionuclide overuse are important challenges that hinder their further development. Methods In the present study, a new small molecule compound (3-[[(2S)-2-hydroxy-3-(4-hydroxyphenyl)-1-carbonyl] amino]-alanine, abbreviation: HN, molecular formula: C12H16N2O5) was synthesized as a linker between radionuclide iodine-125 (125I) and NCs to enable a more efficient binding between NCs and radionuclides. Results In vitro evidence indicated that the linker was able to bind 125I with higher efficiency (labeling efficiency >80%) than that of tyrosine, as well as various NCs, such as cellulose nanofibers, metal oxide NCs, and graphene oxide. Single-photon emission computed tomography/computed tomography imaging demonstrated the biological distribution of 125I-labeled NCs in different organs/tissues after administration in mice. Conclusion These results showed an improvement in radionuclide labeling efficiency for nanocarriers and provided an approach for nanocarrier image tracing.
Collapse
Affiliation(s)
- Ronglin Ma
- Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, 215002, People’s Republic of China
- Department of Gastroenterology, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, 215002, People’s Republic of China
| | - Chunya Ji
- Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, 215002, People’s Republic of China
| | - Mengdan Shen
- Department of Gastroenterology, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, 215002, People’s Republic of China
| | - Shujuan Xu
- Department of Gastroenterology, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, 215002, People’s Republic of China
| | - Guojia Fan
- Center for Cytotoxicity Testing, Sanitation & Environment Technology Institute, Soochow University, Suzhou, Jiangsu, 215006, People’s Republic of China
| | - Chengcheng Wu
- Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, 215002, People’s Republic of China
| | - Qiang Yu
- Department of Gastroenterology, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, 215002, People’s Republic of China
| | - Linliang Yin
- Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, 215002, People’s Republic of China
| |
Collapse
|
47
|
Li YL, Leu HB, Ting CH, Lim SS, Tsai TY, Wu CH, Chung IF, Liang KH. Predicting long-term time to cardiovascular incidents using myocardial perfusion imaging and deep convolutional neural networks. Sci Rep 2024; 14:3802. [PMID: 38360974 PMCID: PMC10869727 DOI: 10.1038/s41598-024-54139-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 02/08/2024] [Indexed: 02/17/2024] Open
Abstract
Myocardial perfusion imaging (MPI) is a clinical tool which can assess the heart's perfusion status, thereby revealing impairments in patients' cardiac function. Within the MPI modality, the acquired three-dimensional signals are typically represented as a sequence of two-dimensional grayscale tomographic images. Here, we proposed an end-to-end survival training approach for processing gray-scale MPI tomograms to generate a risk score which reflects subsequent time to cardiovascular incidents, including cardiovascular death, non-fatal myocardial infarction, and non-fatal ischemic stroke (collectively known as Major Adverse Cardiovascular Events; MACE) as well as Congestive Heart Failure (CHF). We recruited a total of 1928 patients who had undergone MPI followed by coronary interventions. Among them, 80% (n = 1540) were randomly reserved for the training and 5- fold cross-validation stage, while 20% (n = 388) were set aside for the testing stage. The end-to-end survival training can converge well in generating effective AI models via the fivefold cross-validation approach with 1540 patients. When a candidate model is evaluated using independent images, the model can stratify patients into below-median-risk (n = 194) and above-median-risk (n = 194) groups, the corresponding survival curves of the two groups have significant difference (P < 0.0001). We further stratify the above-median-risk group to the quartile 3 and 4 group (n = 97 each), and the three patient strata, referred to as the high, intermediate and low risk groups respectively, manifest statistically significant difference. Notably, the 5-year cardiovascular incident rate is less than 5% in the low-risk group (accounting for 50% of all patients), while the rate is nearly 40% in the high-risk group (accounting for 25% of all patients). Evaluation of patient subgroups revealed stronger effect size in patients with three blocked arteries (Hazard ratio [HR]: 18.377, 95% CI 3.719-90.801, p < 0.001), followed by those with two blocked vessels at HR 7.484 (95% CI 1.858-30.150; p = 0.005). Regarding stent placement, patients with a single stent displayed a HR of 4.410 (95% CI 1.399-13.904; p = 0.011). Patients with two stents show a HR of 10.699 (95% CI 2.262-50.601; p = 0.003), escalating notably to a HR of 57.446 (95% CI 1.922-1717.207; p = 0.019) for patients with three or more stents, indicating a substantial relationship between the disease severity and the predictive capability of the AI for subsequent cardiovascular inciidents. The success of the MPI AI model in stratifying patients into subgroups with distinct time-to-cardiovascular incidents demonstrated the feasibility of proposed end-to-end survival training approach.
Collapse
Affiliation(s)
- Yi-Lian Li
- Institute of Biomedical Informatics, National Yang Ming Chiao Tung University, Taipei City, Taiwan
| | - Hsin-Bang Leu
- Department of Medicine, Taipei Veterans General Hospital, Taipei City, Taiwan
| | - Chien-Hsin Ting
- Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei City, Taiwan
| | - Su-Shen Lim
- Department of Medicine, Taipei Veterans General Hospital, Taipei City, Taiwan
| | - Tsung-Ying Tsai
- Department of Medicine, Taipei Veterans General Hospital, Taipei City, Taiwan
| | - Cheng-Hsueh Wu
- Department of Medicine, Taipei Veterans General Hospital, Taipei City, Taiwan
| | - I-Fang Chung
- Institute of Biomedical Informatics, National Yang Ming Chiao Tung University, Taipei City, Taiwan.
| | - Kung-Hao Liang
- Department of Medical Research, Taipei Veterans General Hospital, Taipei City, Taiwan.
| |
Collapse
|
48
|
Demirtaş CK, Can M, Karadeniz Ö, Çilengiroğlu ÖV, Ertay T, Kaya GÇ. Energy window optimization in bremsstrahlung imaging after Yttrium-90 microsphere therapy. Biomed Phys Eng Express 2024; 10:025028. [PMID: 38306962 DOI: 10.1088/2057-1976/ad25ba] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 02/02/2024] [Indexed: 02/04/2024]
Abstract
In imaging of Yttrium-90 patients treated hepatic primary and metastatic cancers, bremsstrahlung photons produced in a wide energy range is used. However, the image quality depends on acquisition energy window. This research aimed energy window optimization for Yttrium-90 bremsstrahlung imaging and 48 patients with various types of cancer received radioembolization therapy were investigated. Patients were imaged using a GE Healthcare Optima NM/CT 640 series gamma camera system with a medium energy general-purpose (MEGP) collimator and planar images were acquired with 8 different energy windows in the 55-400 keV energy range. The data set, formed with the % FOV, contrast, and spatial resolution of image quality parameters calculated from these images, was statistically examined with ANOVA and Tukey tests. According to the visual evaluations and ANOVA/Tukey test results, it was statistically concluded that energy window of 90-110 keV is the optimal energy window while 60-400 keV energy ranges show the lowest image quality for Y-90 bremsstrahlung imaging.
Collapse
Affiliation(s)
- C Kayaş Demirtaş
- Department of Medical Physics, Institute of Health Sciences, Dokuz Eylül University, 35340, İnciraltı, İzmir, Turkey
| | - M Can
- Department of Medical Physics, Institute of Health Sciences, Dokuz Eylül University, 35340, İnciraltı, İzmir, Turkey
- Program of Nuclear Medicine Techniques, Vocational School of Health Services, Dokuz Eylül University, 35330, İnciralti, İzmir, Turkey
| | - Ö Karadeniz
- Department of Medical Physics, Institute of Health Sciences, Dokuz Eylül University, 35340, İnciraltı, İzmir, Turkey
- Department of Physics, Faculty of Sciences, Dokuz Eylül University, 35390, Tınaztepe, Izmir, Turkey
| | - Ö Vupa Çilengiroğlu
- Department of Statistics, Faculty of Sciences, Dokuz Eylül University, 35390, Tınaztepe, Izmir, Turkey
| | - T Ertay
- Department of Medical Physics, Institute of Health Sciences, Dokuz Eylül University, 35340, İnciraltı, İzmir, Turkey
- Department of Nuclear Medicine, Faculty of Medicine, Dokuz Eylül University, 35340, Inciraltı, Izmir, Turkey
| | - G Çapa Kaya
- Department of Medical Physics, Institute of Health Sciences, Dokuz Eylül University, 35340, İnciraltı, İzmir, Turkey
- Department of Nuclear Medicine, Faculty of Medicine, Dokuz Eylül University, 35340, Inciraltı, Izmir, Turkey
| |
Collapse
|
49
|
Yan Y, Shi X, Li J, Duan W, Zheng S. Five image performances of dual-phase 99mTc-MIBI SPECT/CT in ectopic parathyroid gland localization. QJM 2024; 117:69-72. [PMID: 37802885 DOI: 10.1093/qjmed/hcad230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Indexed: 10/08/2023] Open
Affiliation(s)
- Y Yan
- The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - X Shi
- The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - J Li
- The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - W Duan
- The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - S Zheng
- The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| |
Collapse
|
50
|
Yao J, Fan M, Peng J, Luo H, Lu J. Synthesis and Evaluation of Novel 99mTc-Labeled FGFR2-Targeting Peptides. Mol Pharm 2024; 21:895-903. [PMID: 38170629 DOI: 10.1021/acs.molpharmaceut.3c00998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2024]
Abstract
To develop radiolabeled FGFR2-targeting probes for visualizing fibroblast growth factor receptor (FGFR) expression levels in the tumor microenvironment, four novel 99mTc-labeled FGFR2-targeting peptides ([99mTc]Tc-FGFR2-1, [99mTc]Tc-FGFR2-2, [99mTc]Tc-FGFR2-3, and [99mTc]Tc-FGFR2-4) with different amino acid linkers between the targeted peptide moiety and the 99mTc chelating group were designed and synthesized. The in vitro cellular inhibition, internalization, and efflux results demonstrated that the four 99mTc complexes exhibited FGFR2-specific binding and prolonged cellular retention in DU145 human prostate cancer cells, which indicated that modification from the glycine side (N-terminal) of CH02 was feasible. Among them, [99mTc]Tc-FGFR2-1 exhibited the highest in vitro cellular uptake and in vivo tumor uptake at 30 min postinjection, and tumor uptake could be significantly inhibited by the competitor CH02 (53% inhibited, p < 0.05), suggesting the tumor-specific targeting ability of [99mTc]Tc-FGFR2-1. The DU145-xenografted tumor lesions were clearly visualized by single photon emission computed tomography (SPECT)/CT at 30 min postinjection of [99mTc]Tc-FGFR2-1, highlighting its potential as a SPECT imaging probe for tumor FGFR2 detection.
Collapse
Affiliation(s)
- Jingjing Yao
- Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, P. R. China
| | - Mingxuan Fan
- Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, P. R. China
| | - Jiaying Peng
- Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, P. R. China
| | - Hao Luo
- Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, P. R. China
| | - Jie Lu
- Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, P. R. China
| |
Collapse
|