Comparison of two catheters measuring local impedance: local impedance variation vs lesion characteristics and steam pops. J Interv Card Electrophysiol 2022; 65:419-428. [PMID: 35438394 DOI: 10.1007/s10840-022-01214-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 03/31/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE The size of the distal electrode and the method of measuring local impedance (LI) are different between the IntellaNav MiFi-OI™ (MiFi-OI) and IntellaNav STABLE POINT™ (SP) catheters. We investigated the impact of these differences on LI, efficacy, and safety of radiofrequency (RF) applications. METHODS RF applications at a range of powers (30 W, 40 W, and 50 W), contact forces (10 g and 20 g), and durations (10-120 s) were performed in excised porcine hearts (N = 48). LI variation was defined by δLI-drop (= initial LI - post-RF LI) and %LI-drop (= δLI-drop/initial LI) × 100, and the relationship between lesion characteristics and LI variation was compared. RESULTS A total of 576 lesions were examined. Although absolute δLI-drop during RF applications was significantly larger for the SP than MiFi-OI catheter (47[31-65]ohm for SP vs 37[24-51]ohm for MiFi-OI, p < 0.0001), %LI-drop was similar (23.3 [15.5-30.6]% in SP vs 24.9[17.3-32.5]% in MiFi-OI, p = 0.10). Although lesions produced by both catheters were similarly correlated with LI variation, the SP catheter produced generally larger lesions (depth; 5.0 [3.7-6.1]mm vs 4.7 [3.3-6.0]mm, p = 0.06; surface areas, 46.9 [36.8-58.8]mm2 vs 44.7 [34.3-55.5]mm2, p = 0.02; volume, 321 [165-533]mm3 vs 265[141-471]mm3, p = 0.02). Steam pops were similarly observed with both catheters. In both catheters, %LI-drop was superior to δLI-drop in correlation to lesion size (p < 0.0001) and in predicting steam pops (p < 0.01). CONCLUSIONS Although no difference in safety profile is observed between MiFi-OI and SP catheters, the SP catheter produces larger lesions. %LI-drop is superior to δLI-drop in correlation to lesion size and in predicting steam pops as well as in normalizing the difference between catheters.
Collapse
|
52
|
Sasaki T, Nakamura K, Minami K, Take Y, Nakatani Y, Miki Y, Goto K, Kaseno K, Yamashita E, Koyama K, Naito S. Local impedance measurements during contact force-guided cavotricuspid isthmus ablation for predicting an effective radiofrequency ablation. J Arrhythm 2022; 38:245-252. [PMID: 35387143 PMCID: PMC8977576 DOI: 10.1002/joa3.12680] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 01/05/2022] [Accepted: 01/16/2022] [Indexed: 01/13/2023] Open
Abstract
Background An ablation catheter capable of contact force (CF) and local impedance (LI) monitoring (IntellaNav StablePoint, Boston Scientific) has been recently launched. We evaluated the relationship between the CF and LI values during radiofrequency catheter ablation (RFCA) along the cavotricuspid isthmus (CTI). Methods Fifty consecutive subjects who underwent a CTI-RFCA using IntellaNav StablePoint catheters were retrospectively studied. The initial CF and LI at the start of the RF applications and mean CF and minimum LI during the RF applications were measured. The absolute and percentage LI drops were calculated as the difference between the initial and minimum LIs and 100 × absolute LI drop/initial LI, respectively. Results We analyzed 602 first-pass RF applications. A weak correlation was observed between the initial CF and LI (r = 0.13) and between the mean CF and LI drops (r = 0.22). The initial LI and absolute and percentage LI drops were greater at effective ablation sites than ineffective ablation sites (median, 151 vs. 138 Ω, 22 vs. 14 Ω, and 14.4% vs. 9.9%; p < .001), but the initial and mean CF did not differ. At optimal cutoffs of 21 Ω and 10.8% for the absolute and percentage LI drops according to the receiver-operating characteristic analysis, the sensitivity, and specificity for predicting an effective ablation were 57.4% and 88.9% and 80.0%, and 61.1%, respectively. Conclusions The effective sites during the CF-guided CTI-RFCA had greater initial LI and LI drops than the ineffective sites. Absolute and percentage LI drops of 21 Ω and 10.8% may be appropriate targets for an effective ablation.
Collapse
Affiliation(s)
- Takehito Sasaki
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Kohki Nakamura
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Kentaro Minami
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Yutaka Take
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Yosuke Nakatani
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Yuko Miki
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Koji Goto
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Kenichi Kaseno
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Eiji Yamashita
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Keiko Koyama
- Division of RadiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| | - Shigeto Naito
- Division of CardiologyGunma Prefectural Cardiovascular CenterMaebashi CityJapan
| |
Collapse
|
53
|
Yasumoto K, Egami Y, Kawanami S, Sugae H, Ukita K, Kawamura A, Nakamura H, Matsuhiro Y, Tsuda M, Okamoto N, Matsunaga-Lee Y, Yano M, Nishino M, Tanouchi J. The correlation between local impedance drop and catheter contact in clinical pulmonary vein isolation use. Pacing Clin Electrophysiol 2022; 45:984-992. [PMID: 35363376 DOI: 10.1111/pace.14500] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 02/27/2022] [Accepted: 03/18/2022] [Indexed: 11/28/2022]
Abstract
INTRODUCTION Local impedance (LI) drop during radiofrequency (RF) application is monitored to assess the lesion formation. Recently, a novel ablation catheter has been introduced to clinical setting, which is capable of monitoring LI and catheter contact parameters including contact force (CF) and contact angle (CA). This study aimed to clarify the correlation between LI drop and catheter contact parameters. METHODS AND RESULTS This prospective study included 15 paroxysmal atrial fibrillation (AF) patients who underwent initial pulmonary vein isolation (PVI). First-pass encircling point-by-point PV ablation was performed by using a 4.5-mm irrigated ablation catheter, with monitoring LI, CF, and CA. RF energy was applied for 30 sec at each site with 30W. Stable ablation points were analyzed to examine the correlation between LI drop and catheter contact parameters. Among 903 ablation points, 499 stable ablation points (55.2%) were analyzed. CA showed good correlation with LI drop (ρ = 0.418, P<0.001). Maximum CF, minimum CF, average CF, and initial CF all showed weak correlation with LI drop (ρ = 0.201, P<0.001; ρ = 0.224, P<0.001; ρ = 0.258, P<0.001; and ρ = 0.212, P<0.001, respectively). Multivariate analysis demonstrated that CA was an independent factor of LI drop among the catheter contact parameters (β = 0.139, 95%CI = 0.111-0.167, P<0.001). The LI drop in the blocked segments was significantly higher than that in the electrical conduction gap segments (27.3 ± 9.8 Ω vs. 19.6 ± 6.4 Ω, P<0.001) CONCLUSION: In clinical PVI use, both CF and CA were correlated with LI drop. More parallel CA could induce higher LI drop, which may lead to effective lesion formation. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Koji Yasumoto
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Yasuyuki Egami
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Shodai Kawanami
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Hiroki Sugae
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Kohei Ukita
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Akito Kawamura
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Hitoshi Nakamura
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Yutaka Matsuhiro
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Masaki Tsuda
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Naotaka Okamoto
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | | | - Masamichi Yano
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Masami Nishino
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| | - Jun Tanouchi
- Division of Cardiology, Osaka Rosai Hospital, Sakai, Osaka, Japan
| |
Collapse
|
54
|
Masnok K, Watanabe N. Catheter contact area strongly correlates with lesion area in radiofrequency cardiac ablation: an ex vivo porcine heart study. J Interv Card Electrophysiol 2022; 63:561-572. [PMID: 34499311 PMCID: PMC9151538 DOI: 10.1007/s10840-021-01054-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 08/18/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE Our previous study confirmed that not only force but also the catheter contact angle substantially impacted the contact area and its morphology. Therefore, in this study, we aimed to further investigate the relationship between the catheter contact area and the dimensions of the ablation lesion area as a function of catheter contact angle and force in radiofrequency catheter ablation. METHODS The radiofrequency catheter ablation test was performed for 5 contact angles and 8 contact forces at a fixed ablation time of 30 s. The initial impedance was 92.5 ± 2.5 Ω, the temperature during ablation was 30 °C, and the power was 30 W. The irrigation rate during ablation was set to 17 mL/min. Each experiment was repeated 6 times. RESULTS The catheter contact area showed a strong correlation with the ablation lesion area (r = 0.8507). When the contact area was increased, the lesion area also increased linearly in a monotonic manner. The relationships between catheter contact force and ablation lesion area and between catheter contact force and ablation lesion depth are logarithmic functions in which increased contact force was associated with increased lesion area and depth. The catheter contact angle is also an important determinant of the lesion area. The lesion area progressively increased when the contact angle was decreased. In contrast, the lesion depth progressively increased when the contact angle was increased. CONCLUSIONS The catheter contact area was strongly correlated with the ablation lesion area. Additionally, catheter contact force and contact angle significantly impacted the dimensions of the lesion in radiofrequency catheter ablation procedures.
Collapse
Affiliation(s)
- Kriengsak Masnok
- Biofluid Science and Engineering Laboratory, Functional Control Systems, Graduate School of Engineering and Science, Shibaura Institute of Technology, Room-102, 6th Building, Omiya-Campus, 307 Fukasaku, Minuma-Ku, Saitama-City, Saitama, 337-8570, Japan
| | - Nobuo Watanabe
- Biofluid Science and Engineering Laboratory, Functional Control Systems, Graduate School of Engineering and Science, Shibaura Institute of Technology, Room-102, 6th Building, Omiya-Campus, 307 Fukasaku, Minuma-Ku, Saitama-City, Saitama, 337-8570, Japan.
- Department of Bio-Science and Engineering, College of Systems Engineering and Science, Shibaura Institute of Technology, Saitama, Japan.
| |
Collapse
|
55
|
Asvestas D, Sousonis V, Kotsovolis G, Karanikas S, Xintarakou A, Sakadakis E, Rigopoulos AG, Kalogeropoulos AS, Vardas P, Tzeis S. Cavotricuspid isthmus ablation guided by force-time integral - A randomized study. Clin Cardiol 2022; 45:503-508. [PMID: 35301726 PMCID: PMC9045076 DOI: 10.1002/clc.23805] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 02/13/2022] [Accepted: 02/17/2022] [Indexed: 11/17/2022] Open
Abstract
Background Force‐time integral (FTI) is an ablation marker of lesion quality and transmurality. A target FTI of 400 gram‐seconds (gs) has been shown to improve durability of pulmonary vein isolation, following atrial fibrillation ablation. However, relevant targets for cavotricuspid isthmus (CTI) ablation are lacking. Hypothesis We sought to investigate whether CTI ablation with 600 gs FTI lesions is associated with reduced rate of transisthmus conduction recovery compared to 400 gs lesions. Methods Fifty patients with CTI‐dependent flutter were randomized to ablation using 400 gs (FTI400 group, n = 26) or 600 gs FTI lesions (FTI600 group, n = 24). The study endpoint was spontaneous or adenosine‐mediated recovery of transisthmus conduction, after a 20‐min waiting period. Results The study endpoint occurred in five patients (19.2%) in group FTI400 and in four patients (16.7%) in group FTI600, p = .81. First‐pass CTI block was similar in both groups (50% in FTI400 vs. 54.2% in FTI600, p = .77). There were no differences in the total number of lesions, total ablation time, procedure time and fluoroscopy duration between the two groups. There were no major complications in any group. In the total population, patients not achieving first‐pass CTI block had significantly higher rate of acute CTI conduction recovery, compared to those with first‐pass block (29.2% vs. 7.7% respectively, p = .048). Conclusions CTI ablation using 600 gs FTI lesions is not associated with reduced spontaneous or adenosine‐mediated recurrence of transisthmus conduction, compared to 400 gs lesions.
Collapse
Affiliation(s)
| | | | - George Kotsovolis
- Department of Cardiology, Mitera Hospital, Hygeia Group, Athens, Greece
| | - Stavros Karanikas
- Department of Cardiology, Mitera Hospital, Hygeia Group, Athens, Greece
| | | | | | | | | | - Panos Vardas
- Department of Cardiology, Mitera Hospital, Hygeia Group, Athens, Greece
| | - Stylianos Tzeis
- Department of Cardiology, Mitera Hospital, Hygeia Group, Athens, Greece
| |
Collapse
|
56
|
Themistoclakis S, Calzolari V, De Mattia L, China P, Russo AD, Fassini G, Casella M, Caporaso I, Indiani S, Addis A, Basso C, Della Barbera M, Thiene G, Tondo C. In vivo Lesion Index (LSI) validation in percutaneous radiofrequency catheter ablation. J Cardiovasc Electrophysiol 2022; 33:874-882. [PMID: 35262242 DOI: 10.1111/jce.15442] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 01/06/2022] [Accepted: 01/30/2022] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Lesion Index (LSI) has been developed to predict lesion efficacy during radiofrequency (RF) catheter ablation. However, its value in predicting lesions size has still to be established. The aim of our study was to assess the lesions size reproducibility for pre-specified values of LSI reached during RF delivery in an in vivo beating heart. METHODS Ablation lesions were created with different values of LSI in 7 domestic pigs by means of a contact force sensing catheter (TactiCathTM , Abbott). Lesions were identified during RF delivery by means of a 3D mapping system (EnSiteTM Precision, Abbott) and measured after heart explantation. Histology was carried out after gross examination on the first 3 lesions to confirm the accuracy of the macroscopic evaluation. RESULTS A total of 64 myocardial lesions were created. Thirty-nine lesions were excluded from the analysis for the following reasons: histological confirmation of macroscopic lesion measurement (n=3), transmurality (n=24), unfavorable anatomic position (n=10), not macroscopically identifiable (n=2). In a final set of 25 non-transmural lesions, injury width and depth were respectively 4.6±0.6 mm and 2.6±0.8 mm for LSI=4, 7.3±0.8 mm and 4.7±0.6 mm for LSI=5, and 8.6±1.2 mm and 7.2±1.1 mm for LSI=6. A strong linear correlation was observed between LSI and lesion width (r=0.87, p<0.00001) and depth (r=0.89, p<0.00001). Multiple linear regression analysis identified LSI as the only ablation parameter that significantly predicted lesion width (p<0.001) and depth (p<0.001). CONCLUSION In our in vivo study, LSI proved highly predictive of lesion size and depth. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
| | | | - Luca De Mattia
- Ospedale Ca'Foncello-ULSS2 Marca Trevigiana, Treviso, Italy
| | - Paolo China
- Ospedale dell'Angelo-ULSS3 Serenissima, Mestre-Venice, Italy
| | | | - Gaetano Fassini
- Heart Rhythm Center, Monzino Cardiac Center, IRCCS, Milan, Italy
| | - Michela Casella
- Heart Rhythm Center, Monzino Cardiac Center, IRCCS, Milan, Italy
| | - Igor Caporaso
- Abbott Medical Italia S.p.A., Sesto San Giovanni, Italy
| | | | - Alessandro Addis
- CRABCC, Biotechnology Research Center for Cardiothoracic Applications, Rivolta D'Adda, Italy
| | - Cristina Basso
- Cardiovascular Pathology, Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Padova, Italy
| | - Mila Della Barbera
- Cardiovascular Pathology, Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Padova, Italy
| | - Gaetano Thiene
- Cardiovascular Pathology, Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Padova, Italy
| | - Claudio Tondo
- Heart Rhythm Center, Monzino Cardiac Center, IRCCS, Milan, Italy.,Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy
| |
Collapse
|
57
|
Enriquez AD, Kattel S. Radiofrequency Ablation: Four Decades Later, Still Optimizing Lesion Characterization. J Cardiovasc Electrophysiol 2022; 33:883-884. [PMID: 35262984 DOI: 10.1111/jce.15445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Accepted: 02/26/2022] [Indexed: 11/28/2022]
Abstract
Intracardiac catheter ablation was first introduced in the early 1980s with a direct current shock used as the energy source. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Alan D Enriquez
- Section of Cardiovascular Medicine, Yale University School of Medicine, New Haven, CT.,VA Connecticut Healthcare System, West Haven, CT
| | - Sharma Kattel
- Section of Cardiovascular Medicine, Yale University School of Medicine, New Haven, CT
| |
Collapse
|
58
|
Optimal Ablation Settings Predicting Durable Scar Detected Using LGE-MRI after Modified Left Atrial Anterior Line Ablation. J Clin Med 2022; 11:jcm11030830. [PMID: 35160281 PMCID: PMC8837068 DOI: 10.3390/jcm11030830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 01/25/2022] [Accepted: 02/02/2022] [Indexed: 02/05/2023] Open
Abstract
(1) Background: The modified anterior line (MAL) has been described as an alternative to the mitral isthmus line. Despite better ablation results, achieving a bidirectional line block can be challenging. We aimed to investigate the ablation parameters that determine a persistent scar on late-gadolinium enhancement magnet resonance imaging (LGE-MRI) as a surrogate parameter for successful ablation 3 months after MAL ablation. (2) Methods: Twenty-four consecutive patients who underwent a MAL ablation have been included. The indication for MAL was perimitral flutter (n = 5) or substrate ablation in the diffuse anterior left atrial (LA) low-voltage area in persistent atrial fibrillation (AF) (n = 19). The MAL was divided into three segments: segment 1 (S1) from mitral annulus to height of lower region of left atrial appendage (LAA) antrum; segment 2 (S2) height of lower region of LAA antrum to end of upper LAA antrum; segment 3 (S3) from end of upper LAA antrum to left superior pulmonary vein. Ablation was performed using a contact force irrigated catheter with a power of 40 Watt and guided by automated lesion tagging and the Ablation Index (AI). The AI target was left to the operator’s choice. An inter-lesion distance of ≤6 mm was recommended. The bidirectional block was systematically evaluated using stimulation maneuvers at the end of procedure. All patients underwent LGE-MRI imaging at 3 months, regardless of symptoms, to identify myocardial lesions (scars). (3) Results: Bidirectional MAL block was achieved in all patients. LGE-MRI imaging revealed scarring in 45 of 72 (63%) segments. In all three segments of MAL, ablation time and AI were significantly higher in scarred areas compared with non-scar areas. The mean AI value to detect a durable scar was 514.2 in S1, 486.7 in S2 and 485.9 in S3. The mean ablation time to detect a scar was 20.4 s in S1, 22.1 s in S2 and 20.2 s in S3. Mean contact force and impedance drop were not significantly different between scar and non-scar areas. (4) Conclusions: Targeting optimal AI values is crucial to determine persistent left atrial scars on an LGE-MRI scan 3 months after ablation. AI guided linear left atrial ablation seems to be effective in producing durable lesions.
Collapse
|
59
|
Pérez JJ, Nadal E, Berjano E, González-Suárez A. Computer modeling of radiofrequency cardiac ablation including heartbeat-induced electrode displacement. Comput Biol Med 2022; 144:105346. [DOI: 10.1016/j.compbiomed.2022.105346] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 02/13/2022] [Accepted: 02/21/2022] [Indexed: 12/12/2022]
|
60
|
Karkowski G, Kuniewicz M, Ząbek A, Koźluk E, Dębski M, Matusik PT, Lelakowski J. Contact Force-Sensing versus Standard Catheters in Non-Fluoroscopic Radiofrequency Catheter Ablation of Idiopathic Outflow Tract Ventricular Arrhythmias. J Clin Med 2022; 11:jcm11030593. [PMID: 35160043 PMCID: PMC8836481 DOI: 10.3390/jcm11030593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Revised: 01/10/2022] [Accepted: 01/21/2022] [Indexed: 12/04/2022] Open
Abstract
Background: Adequate contact between the catheter tip and tissue is important for optimal lesion formation and, in some procedures, it has been associated with improved effectiveness and safety. We evaluated the potential benefits of contact force-sensing (CFS) catheters during non-fluoroscopic radiofrequency catheter ablation (NF-RFCA) of idiopathic ventricular arrhythmias (VAs) originating from outflow tracts (OTs). Methods: A group of 102 patients who underwent NF-RFCA (CARTO, Biosense Webster Inc., Irvine, CA, USA) of VAs from OTs between 2014 to 2018 was retrospectively analyzed. Results: We included 52 (50.9%) patients in whom NF-RFCA was performed using CFS catheters and 50 (49.1%) who were ablated using standard catheters. Arrhythmias were localized in the right and left OT in 70 (68.6%) and 32 (31.4%) patients, respectively. The RFCA acute success rate was 96.1% (n = 98) and long-term success during a minimum 12-month follow-up (mean 51.3 ± 21.6 months) was 85.3% (n = 87), with no difference between CFS and standard catheters. There was no difference in complications rate between CFS (n = 1) and standard catheter (n = 2) ablations. Conclusions: There is no additional advantage of CFS catheters use over standard catheters during NF-RFCA of OT-VAs in terms of procedural effectiveness and safety.
Collapse
Affiliation(s)
- Grzegorz Karkowski
- Department of Electrocardiology, The John Paul II Hospital, 31-202 Kraków, Poland; (G.K.); (M.K.); (A.Z.); (J.L.)
| | - Marcin Kuniewicz
- Department of Electrocardiology, The John Paul II Hospital, 31-202 Kraków, Poland; (G.K.); (M.K.); (A.Z.); (J.L.)
- Department of Anatomy, Jagiellonian University Medical College, 31-008 Kraków, Poland
| | - Andrzej Ząbek
- Department of Electrocardiology, The John Paul II Hospital, 31-202 Kraków, Poland; (G.K.); (M.K.); (A.Z.); (J.L.)
| | - Edward Koźluk
- Department of Cardiology, Medical University of Warsaw, 02-097 Warsaw, Poland;
| | - Maciej Dębski
- Department of Cardiology, Norfolk and Norwich University Hospital, University of East Anglia, Norwich NR4 7TJ, UK;
| | - Paweł T. Matusik
- Department of Electrocardiology, The John Paul II Hospital, 31-202 Kraków, Poland; (G.K.); (M.K.); (A.Z.); (J.L.)
- Department of Electrocardiology, Institute of Cardiology, Jagiellonian University Medical College, 31-008 Kraków, Poland
- Correspondence: ; Tel.: +48-12-614-2277
| | - Jacek Lelakowski
- Department of Electrocardiology, The John Paul II Hospital, 31-202 Kraków, Poland; (G.K.); (M.K.); (A.Z.); (J.L.)
- Department of Electrocardiology, Institute of Cardiology, Jagiellonian University Medical College, 31-008 Kraków, Poland
| |
Collapse
|
61
|
Matsuura G, Fukaya H, Ogawa E, Kawakami S, Mori H, Saito D, Sato T, Nakamura H, Ishizue N, Oikawa J, Kishihara J, Niwano S, Ako J. Catheter contact angle influences local impedance drop during radiofrequency catheter ablation: Insight from a porcine experimental study with 2 different LI-sensing catheters. J Cardiovasc Electrophysiol 2022; 33:380-388. [PMID: 35018687 DOI: 10.1111/jce.15356] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 11/23/2021] [Accepted: 01/01/2022] [Indexed: 11/26/2022]
Abstract
BACKGROUND Local impedance (LI) can indirectly measure catheter contact and tissue temperature during radiofrequency catheter ablation (RFCA). However, data on the effects of catheter contact angle on LI parameters are scarce. This study aimed to evaluate the influence of catheter contact angle on LI changes and lesion size with 2 different LI-sensing catheters in a porcine experimental study. METHODS Lesions were created by the INTELLANAV MiFi™ OI (MiFi) and the INTELLANAV STABLEPOINT™ (STABLEPOINT). RFCA was performed with 30 watts and a duration of 30 seconds. The CF (0, 5, 10, 20, and 30 g) and catheter contact angle (30°, 45°, and 90°) were changed in each set (n=8 each). The LI rise, LI drop, and lesion size were evaluated. RESULTS The LI rise increased as CF increased. There was no angular dependence with the LI rise under all CFs in the MiFi. On the other hand, the LI rise at 90° was lower than at 30° under 5 and 10 g of CF in STABLEPOINT. The LI drop increased as CF increased. Regarding the difference in catheter contact angles, the LI drop at 90° was lower than that at 30° for both catheters. The maximum lesion widths and surface widths were smaller at 90° than at 30°, whereas there were no differences in lesion depths. CONCLUSION The LI drop and lesion widths at 90° were significantly smaller than those at 30°, although the lesion depths were not different among the 3 angles for the MiFi and STABLEPOINT. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Gen Matsuura
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan
| | - Hidehira Fukaya
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan
| | - Emiyu Ogawa
- Department of Medical Engineering and Technology, Kitasato University School of Allied Health Sciences, Sagamihara, Kanagawa, Japan
| | - Sota Kawakami
- Department of Medical Engineering and Technology, Kitasato University School of Allied Health Sciences, Sagamihara, Kanagawa, Japan
| | - Hitoshi Mori
- Department of Cardiology, Saitama Medical University International Medical Center, Hidaka, Saitama, Japan
| | - Daiki Saito
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan
| | - Tetsuro Sato
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan
| | - Hironori Nakamura
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan
| | - Naruya Ishizue
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan
| | - Jun Oikawa
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan
| | - Jun Kishihara
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan
| | - Shinichi Niwano
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan
| | - Junya Ako
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan
| |
Collapse
|
62
|
Lozano Granero C, Franco E, Matía Francés R, Hernández-Madrid A, Sánchez-Pérez I, Zamorano Gómez JL, Moreno J. Impact of power and contact force on index-guided radiofrequency lesions in an ex vivo porcine heart model. J Interv Card Electrophysiol 2022; 63:687-697. [PMID: 34997886 DOI: 10.1007/s10840-021-01110-y] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Accepted: 12/27/2021] [Indexed: 11/28/2022]
Abstract
PURPOSE Lesion size index (LSI) and ablation index (AI) are markers of lesion quality that incorporate power, contact force (CF) and time in a weighted formula to estimate lesion size. Although accurate predicting lesion depth in vitro, their precision in lesion size estimation has not been well established for certain power and CF settings. We conducted an experimental ex vivo study to analyse the effect of power and CF in size and morphology of ablation lesions in a porcine heart model. METHODS Twenty-four sets of 10 perpendicular epicardial radiofrequency applications were performed with two commercially available catheters (TactiCath, Sensor Enabled; and SmartTouch) on porcine left ventricle submerged in 37 °C saline, combining different power (25, 30, 35, 40, 50 and 60 W) and CF (10 and 20 g) settings, and aiming at a lower (LSI/AI of 5/400) or higher (LSI/AI of 6/550) index. After each application, lesions were cross-sectioned and measured. RESULTS Four hundred eighty lesions were performed. For a given target index and CF, significant differences in lesion volume and depth with different power were observed with both catheters, generally with smaller lesions using higher power. Lesions performed with CF of 10 g were particularly smaller with TactiCath compared to SmartTouch; lesions with CF of 20 g aiming a low LSI/AI were, however, bigger; lesions with CF of 20 g aiming a high LSI/AI were similar. In general, high-power lesions were wider and shallower than low-power lesions, especially with SmartTouch. CONCLUSION Size and morphology of index-guided radiofrequency lesions varied significantly with different power and CF settings.
Collapse
Affiliation(s)
- Cristina Lozano Granero
- Cardiology Department, Arrhythmia Unit, University Hospital Ramón Y Cajal, M-607, km 9100, 28034, Madrid, Spain.
| | - Eduardo Franco
- Cardiology Department, Arrhythmia Unit, University Hospital Ramón Y Cajal, M-607, km 9100, 28034, Madrid, Spain
| | - Roberto Matía Francés
- Cardiology Department, Arrhythmia Unit, University Hospital Ramón Y Cajal, M-607, km 9100, 28034, Madrid, Spain
| | - Antonio Hernández-Madrid
- Cardiology Department, Arrhythmia Unit, University Hospital Ramón Y Cajal, M-607, km 9100, 28034, Madrid, Spain
| | - Inmaculada Sánchez-Pérez
- Paediatric Cardiology Department, Arrhythmia Unit, University Hospital Ramón Y Cajal, M-607, km 9100, 28034, Madrid, Spain
| | | | - Javier Moreno
- Cardiology Department, Arrhythmia Unit, University Hospital Ramón Y Cajal, M-607, km 9100, 28034, Madrid, Spain
| |
Collapse
|
63
|
Schlögl S, Schlögl KS, Bengel P, Bergau L, Haarmann H, Rasenack E, Hasenfuss G, Zabel M. Impact of open-irrigated radiofrequency catheter with contact force measurement on the efficacy and safety of atrial fibrillation ablation: a single-center direct comparison. J Interv Card Electrophysiol 2022; 65:685-693. [PMID: 35907108 PMCID: PMC9726666 DOI: 10.1007/s10840-022-01316-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Accepted: 07/20/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND In atrial fibrillation (AF) patients, catheter ablation of pulmonary veins (PVI) is the most effective therapeutic option to maintain sinus rhythm. To improve successful PVI, contact force-sensing (CF) catheters became routinely available. Previous studies did not clearly show superior clinical efficacy in comparison with non-CF catheters. METHODS We investigated consecutive patients, who underwent index PVI for AF at our hospital between 2012 and 2018. Three hundred and fifty-four patients were ablated without CF. After availability of CF catheters in 2016, 317 patients were ablated using CF. In case of crossover between the groups, follow-up was censored. The primary endpoint was any documented atrial tachycardia (AT) or atrial fibrillation > 30 s after a 3-month blanking period. Secondary endpoints were procedural characteristics and periprocedural complications. RESULTS There was no significant difference between the groups at baseline except hyperlipidemia. After 365 days of follow-up, 67% of patients in the CF group remained free from AF/AT recurrence compared to 59% in non-CF group (P = 0.038). In multivariable Cox regression analysis, non-CF ablation was an independent risk factor for AF recurrence besides age and persistent AF. Total fluoroscopy time (15 ± 7.6 vs. 28 ± 15.9 min) and total procedure time (114 ± 29.6 vs. 136 ± 38.5 min) were significantly lower for CF-guided PVI (P < 0.001). Complication rates did not differ between groups (P = 0.661). CONCLUSIONS In our study, the AT/AF recurrence rate and pulmonary vein reconnection rate is lower after CF PVI with a similar complication rate but lower total procedure time and total fluoroscopy time compared to non-CF PVI.
Collapse
Affiliation(s)
- Simon Schlögl
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany ,grid.452396.f0000 0004 5937 5237DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany
| | - Klaudia Stella Schlögl
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany
| | - Philipp Bengel
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany ,grid.452396.f0000 0004 5937 5237DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany
| | - Leonard Bergau
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany
| | - Helge Haarmann
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany ,grid.452396.f0000 0004 5937 5237DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany
| | - Eva Rasenack
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany
| | - Gerd Hasenfuss
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany ,grid.452396.f0000 0004 5937 5237DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany
| | - Markus Zabel
- grid.411984.10000 0001 0482 5331Department of Cardiology and Pneumology, Heart Center, University Medical Center, Robert-Koch-Str. 40, 37075 Göttingen, Germany ,grid.452396.f0000 0004 5937 5237DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, Göttingen, Germany
| |
Collapse
|
64
|
Mulder MJ, Kemme MJB, Allaart CP. Radiofrequency ablation to achieve durable pulmonary vein isolation. Europace 2021; 24:874-886. [PMID: 34964469 DOI: 10.1093/europace/euab279] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Indexed: 11/13/2022] Open
Abstract
Pulmonary vein isolation (PVI) by radiofrequency (RF) ablation is an important alternative to antiarrhythmic drugs in the treatment of symptomatic atrial fibrillation. However, the inability to consistently achieve durable isolation of the pulmonary veins hampers the long-term efficacy of PVI procedures. The large number of factors involved in RF lesion formation and the complex interplay of these factors complicate reliable creation of durable and transmural ablation lesions. Various surrogate markers of ablation lesion formation have been proposed that may provide information on RF lesion completeness. Real-time assessment of these surrogates may aid in the creation of transmural ablation lesions, and therefore, holds potential to decrease the risk of PV reconnection and consequent post-PVI arrhythmia recurrence. Moreover, titration of energy delivery until lesions is transmural may prevent unnecessary ablation and subsequent adverse events. Whereas several surrogate markers of ablation lesion formation have been described over the past decades, a 'gold standard' is currently lacking. This review provides a state-of-the-art overview of ablation strategies that aim to enhance durability of RF-PVI, with special focus on real-time available surrogates of RF lesion formation in light of the biophysical basis of RF ablation.
Collapse
Affiliation(s)
- Mark J Mulder
- Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam Cardiovascular Sciences, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Michiel J B Kemme
- Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam Cardiovascular Sciences, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| | - Cornelis P Allaart
- Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam Cardiovascular Sciences, De Boelelaan 1117, 1081 HV Amsterdam, The Netherlands
| |
Collapse
|
65
|
Shin D, Kim HU, Kulkarni A, Kim YH, Kim T. Development of Force Sensor System Based on Tri-Axial Fiber Bragg Grating with Flexure Structure. SENSORS (BASEL, SWITZERLAND) 2021; 22:16. [PMID: 35009561 PMCID: PMC8747225 DOI: 10.3390/s22010016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 12/13/2021] [Accepted: 12/17/2021] [Indexed: 06/14/2023]
Abstract
Fiber Bragg grating (FBG) sensors have an advantage over optical sensors in that they are lightweight, easy to terminate, and have a high flexibility and a low cost. Additionally, FBG is highly sensitive to strain and temperature, which is why it has been used in FBG force sensor systems for cardiac catheterization. When manually inserting the catheter, the physician should sense the force at the catheter tip under the limitation of power (<0.5 N). The FBG force sensor can be optimal for a catheter as it can be small, low-cost, easy to manufacture, free of electromagnetic interference, and is materially biocompatible with humans. In this study, FBG fibers mounted on two different flexure structures were designed and simulated using ANSYS simulation software to verify their sensitivity and durability for use in a catheter tip. The selected flexure was combined with three FBGs and an interrogator to obtain the wavelength signals. To obtain a calibration curve, the FBG sensor obtained data on the change in wavelength with force at a high resolution of 0.01 N within the 0.1-0.5 N range. The calibration curve was used in the force sensor system by the LabVIEW program to measure the unknown force values in real time.
Collapse
Affiliation(s)
- Dongjoo Shin
- School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea;
| | - Hyeong-U Kim
- Department of Plasma Engineering, Korea Institute of Machinery & Materials (KIMM), Daejeon 34103, Korea;
| | - Atul Kulkarni
- Symbiosis Centre for Nanoscience and Nanotechnology, Symbiosis International (Deemed University), Pune 412115, India;
| | - Young-Hak Kim
- Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea;
| | - Taesung Kim
- School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea;
- SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon 16419, Korea
| |
Collapse
|
66
|
Zhao X, Ziv O, Mohammadpour R, Crosby B, Hoyt WJ, Jenkins MW, Snyder C, Hendon C, Laurita KR, Rollins AM. Polarization-sensitive optical coherence tomography monitoring of percutaneous radiofrequency ablation in left atrium of living swine. Sci Rep 2021; 11:24330. [PMID: 34934120 PMCID: PMC8692484 DOI: 10.1038/s41598-021-03724-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Accepted: 12/06/2021] [Indexed: 11/12/2022] Open
Abstract
Radiofrequency ablation (RFA) is commonly used to treat atrial fibrillation (AF). However, the outcome is often compromised due to the lack of direct real-time feedback to assess lesion transmurality. In this work, we evaluated the ability of polarization-sensitive optical coherence tomography (PSOCT) to measure cardiac wall thickness and assess RF lesion transmurality during left atrium (LA) RFA procedures. Quantitative transmural lesion criteria using PSOCT images were determined ex vivo using an integrated PSOCT-RFA catheter and fresh swine hearts. LA wall thickness of living swine was measured with PSOCT and validated with a micrometer after harvesting the heart. A total of 38 point lesions were created in the LA of 5 living swine with the integrated PSOCT-RFA catheter using standard clinical RFA procedures. For all lesions with analyzable PSOCT images, lesion transmurality was assessed with a sensitivity of 89% (17 of 19 tested positive) and a specificity of 100% (5 of 5 tested negative) using the quantitative transmural criteria. This is the first report of using PSOCT to assess LA RFA lesion transmurality in vivo. The results indicate that PSOCT may potentially provide direct real-time feedback for LA wall thickness and lesion transmurality.
Collapse
Affiliation(s)
- Xiaowei Zhao
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Ohad Ziv
- School of Medicine, Case Western Reserve University, Cleveland, OH, USA
- Heart and Vascular Research Center, MetroHealth Medical Center, Cleveland, OH, USA
| | | | - Benjamin Crosby
- Department of Chemistry, Case Western Reserve University, Cleveland, OH, USA
| | - Walter J Hoyt
- Department of Pediatrics, Ochsner Health, New Orleans, LA, USA
| | - Michael W Jenkins
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
- Department of Pediatrics, Case Western Reserve University, Cleveland, OH, USA
| | - Christopher Snyder
- School of Medicine, Case Western Reserve University, Cleveland, OH, USA
- The Congenital Heart Collaborative, Rainbow Babies and Children's Hospital, Cleveland, OH, USA
| | - Christine Hendon
- Department of Electrical Engineering, Columbia University, New York, NY, USA
| | - Kenneth R Laurita
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
- Heart and Vascular Research Center, MetroHealth Medical Center, Cleveland, OH, USA
| | - Andrew M Rollins
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
- School of Medicine, Case Western Reserve University, Cleveland, OH, USA.
| |
Collapse
|
67
|
Stevenson WG, Sapp JL. Newer Methods for VT Ablation and When to Use Them. Can J Cardiol 2021; 38:502-514. [PMID: 34942300 DOI: 10.1016/j.cjca.2021.12.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 12/03/2021] [Accepted: 12/11/2021] [Indexed: 02/07/2023] Open
Abstract
Radiofrequency (RF) catheter ablation has long been an important therapy for ventricular tachycardia and frequent symptomatic premature ventricular beats and nonsustained arrhythmias when antiarrhythmic drugs fail to suppress the arrhythmias. It is increasingly used in preference to antiarrhythmic drugs, sparing the patient drug adverse effects. Ablation success varies with the underlying heart disease and type of arrhythmia, being very effective for patients without structural heart disease, less in structural heart disease. Failure occurs when a target for ablation cannot be identified, or ablation lesions fail to reach and abolish the arrhythmia substrate that may be extensive, intramural or subepicardial in location. Approaches to improving ablation lesion creation are modifications to RF ablation and emerging investigational techniques. Easily implemented modifications to RF methods include manipulating the size and location of the cutaneous dispersive electrode, increasing RF delivery duration, and use of lower tonicity catheter irrigation (usually 0.45% saline). When catheters can be placed on either side of culprit substrate RF can be delivered in a bipolar or simultaneous unipolar configuration that can be successful. Catheters with extendable/retractable irrigated needles for RF delivery are under investigation in clinical trials. Cryoablation is potentially useful in specific situations when maintaining contact is difficult. Transvascular ethanol ablation and stereotactic radioablation have both shown promise for arrhythmias that fail other ablation strategies. Although substantial clinical progress has been achieved, further improvement is clearly needed. With ability to increase ablation lesion size, continued careful evaluation of safety, which has been excellent for standard RF ablation, remains important.
Collapse
Affiliation(s)
- William G Stevenson
- The Cardiovascular Division, Department of Medicine, Vanderbilt University Medical Center, Nashville, Tennessee; The Heart Rhythm Service, Department of Medicine, Division of Cardiology, QEII Health Sciences Centre, Halifax, Nova Scotia, Canada.
| | - John L Sapp
- The Cardiovascular Division, Department of Medicine, Vanderbilt University Medical Center, Nashville, Tennessee; The Heart Rhythm Service, Department of Medicine, Division of Cardiology, QEII Health Sciences Centre, Halifax, Nova Scotia, Canada
| |
Collapse
|
68
|
Kashiwagi M, Kuroi A, Katayama Y, Terada K, Fujita S, Hozumi T, Shimamura K, Shiono Y, Tanimoto T, Kubo T, Tanaka A, Akasaka T. Impact of cavotricuspid isthmus depth on the ablation index for successful first-pass typical atrial flutter ablation. Sci Rep 2021; 11:22413. [PMID: 34789842 PMCID: PMC8599492 DOI: 10.1038/s41598-021-01846-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Accepted: 11/01/2021] [Indexed: 11/18/2022] Open
Abstract
Cavotricuspid isthmus (CTI) linear ablation has been established as the treatment for typical atrial flutter. Recently, ablation index (AI) has emerged as a novel marker for estimating ablation lesions. We investigated the relationship between CTI depth and ablation parameters on the procedural results of typical atrial flutter ablation. A total of 107 patients who underwent CTI ablation were retrospectively enrolled in this study. All patients underwent computed tomography before catheter ablation. From the receiver-operating curve, the best cut-off value of CTI depth was < 4.1 mm to predict first-pass success. Although the average AI was not different between deep CTI (DC; CTI depth ≥ 4.1) and shallow CTI (SC; CTI depth < 4.1), DC required a longer ablation time and showed a lower first-pass success rate (p < 0.01). In addition, the catheter inversion technique was more frequently required in the DC (p < 0.01). The lowest AI sites of the first-pass CTI line were determined in both the ventricular (2/3 segment of CTI) and inferior vena cava (IVC, 1/3 segment of CTI) sides. The best cut-off values of the weakest AIs at the ventricular and IVC sides for predicting first-pass success were > 420 and > 386, respectively. Among patients with these cut-off values, the first-pass success rate was 89% in the SC and 50% in the DC (p < 0.01). Although ablation parameters were not significantly different, the first-pass success rate was lower in the DC than in the SC. Further investigation might be required for better outcomes in deep CTIs.
Collapse
Affiliation(s)
- Manabu Kashiwagi
- Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan.
| | - Akio Kuroi
- Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan
| | - Yosuke Katayama
- Department of Cardiovascular Medicine, Shingu Municipal Medical Center, 18-7, Hachibuse, Shingu, Wakayama, 647-0072, Japan
| | - Kosei Terada
- Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan
| | - Suwako Fujita
- Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan
| | - Takeshi Hozumi
- Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan
| | - Kunihiro Shimamura
- Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan
| | - Yasutsugu Shiono
- Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan
| | - Takashi Tanimoto
- Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan
| | - Takashi Kubo
- Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan
| | - Atsushi Tanaka
- Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan
| | - Takashi Akasaka
- Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan
| |
Collapse
|
69
|
Kella D, Padmanabhan D. Ablation index in AF. Indian Pacing Electrophysiol J 2021; 21:342-343. [PMID: 34749980 PMCID: PMC8577120 DOI: 10.1016/j.ipej.2021.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Affiliation(s)
| | - Deepak Padmanabhan
- Sri Jayadeva Institute of Cardiovascular Sciences and Research, Bangalore, 69, India.
| |
Collapse
|
70
|
Tonegawa-Kuji R, Yamagata K, Suzuki S, Miyazaki Y, Ueda N, Kusano K. Prompt recognition and successful aspiration of a left atrial thrombus under intracardiac echocardiography guidance during radiofrequency catheter ablation for atrial tachycardia. Europace 2021; 23:1527. [PMID: 34477861 DOI: 10.1093/europace/euab210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Affiliation(s)
- Reina Tonegawa-Kuji
- Division of Arrhythmia and Electrophysiology, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, 6-1, Kishibe-Shimmachi, Suita, Osaka 564-8565, Japan
| | - Kenichiro Yamagata
- Division of Arrhythmia and Electrophysiology, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, 6-1, Kishibe-Shimmachi, Suita, Osaka 564-8565, Japan
| | - Sho Suzuki
- Division of Arrhythmia and Electrophysiology, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, 6-1, Kishibe-Shimmachi, Suita, Osaka 564-8565, Japan
| | - Yuichiro Miyazaki
- Division of Arrhythmia and Electrophysiology, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, 6-1, Kishibe-Shimmachi, Suita, Osaka 564-8565, Japan
| | - Nobuhiko Ueda
- Division of Arrhythmia and Electrophysiology, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, 6-1, Kishibe-Shimmachi, Suita, Osaka 564-8565, Japan
| | - Kengo Kusano
- Division of Arrhythmia and Electrophysiology, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, 6-1, Kishibe-Shimmachi, Suita, Osaka 564-8565, Japan
| |
Collapse
|
71
|
Okamatsu H, Okumura K, Kaneko S, Negishi K, Hayashi K, Tsurugi T, Tanaka Y, Nakao K, Sakamoto T, Koyama J. Ablation Index-Guided High-Power Radiofrequency Application Shortens the Procedure Time With Similar Outcomes to Conventional Power Application in Atrial Fibrillation Ablation. Circ Rep 2021; 3:559-568. [PMID: 34703933 PMCID: PMC8492404 DOI: 10.1253/circrep.cr-21-0099] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Accepted: 07/18/2021] [Indexed: 11/21/2022] Open
Abstract
Background:
The impact of high-power radiofrequency (RF) application in ablation index (AI)-guided atrial fibrillation (AF) ablation has not been elucidated. Methods and Results:
We investigated 1,333 patients undergoing first AF ablation (median age 68 years; interquartile range [IQR] 61–73 years). The first 301 patients underwent AI-guided conventional power RF application (CP group), whereas the following 1,032 patients underwent high-power RF application (HP group). The minimum AI target values were 400, 360, and 260 at the left atrial anterior wall, posterior wall, and esophagus, respectively. RF power in the CP group was 30–40, 20–25, and 20 W at the anterior wall, posterior wall, and esophagus, respectively, compared with 50, 40, and 25, respectively, in the HP group. Procedure time was shorter in the HP than CP group (median 153 [IQR 129–190] vs. 180 (IQR 152–229) min; P<0.0001). The percentage of first-pass pulmonary vein isolation (69% vs. 73%; P=0.07) and all procedure-related complications (2.0% vs. 3.4%; P=0.19) was similar. Kaplan-Meier analysis showed similar recurrence-free survival (RFS) for all AF types. Respective 1-year RFS in the CP and HP groups was 82% and 87% in paroxysmal AF, 78% and 82% in persistent AF, and 59% and 58% in long-standing persistent AF. Conclusions:
In AI-guided AF ablation, high-power RF application shortens the procedure time without increasing complications and with similar outcomes.
Collapse
Affiliation(s)
- Hideharu Okamatsu
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Ken Okumura
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Shozo Kaneko
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Kodai Negishi
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Katsuhide Hayashi
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Takuo Tsurugi
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Yasuaki Tanaka
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Koichi Nakao
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Tomohiro Sakamoto
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Junjiroh Koyama
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| |
Collapse
|
72
|
Park J, Cha DI, Jeong Y, Park H, Lee J, Kang TW, Lim HK, Park I. Real-Time Internal Steam Pop Detection during Radiofrequency Ablation with a Radiofrequency Ablation Needle Integrated with a Temperature and Pressure Sensor: Preclinical and Clinical Pilot Tests. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:e2100725. [PMID: 34351701 PMCID: PMC8498861 DOI: 10.1002/advs.202100725] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 05/29/2021] [Indexed: 06/13/2023]
Abstract
A radiofrequency ablation (RFA) needle integrated with a temperature sensor (T-sensor) and pressure sensor (P-sensor) is designed and utilized for real-time internal steam pop monitoring during RFA. The characteristics of the sensor-integrated RFA needle (sRFA-needle) are investigated quantitatively using a pressure chamber system, and the feasibility and usability of the needle in preclinical and clinical trials is demonstrated. The sharp changes in the temperature and normalized pressure sensor signals induced by the abrupt release of hot and high-pressure steam can be clearly monitored during the steam pop phenomena. The basic mechanism of the preliminary steam pop is hypothesized and verified using in situ ultrasound imaging data and computational analysis data of the RFA procedure. Moreover, the usability of the system in clinical trials is investigated, and the steam pop phenomena during the RFA procedure are detected using T-sensor and P-sensor. The results confirm that the sensor integration on the medical needle can provide critical data for safer and more effective medical practices.
Collapse
Affiliation(s)
- Jaeho Park
- Department of Mechanical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141South Korea
- Present address:
Department of Chemical EngineeringStanford UniversityStanfordCA94305United States
| | - Dong Ik Cha
- Radiology and Center for Imaging ScienceSamsung Medical CenterSungkyunkwan University School of MedicineSeoul06351South Korea
| | - Yongrok Jeong
- Department of Mechanical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141South Korea
| | - Hayan Park
- Radiology and Center for Imaging ScienceSamsung Medical CenterSungkyunkwan University School of MedicineSeoul06351South Korea
| | - Jinwoo Lee
- RF Medical Co. Ltd.Seoul08511South Korea
| | - Tae Wook Kang
- Radiology and Center for Imaging ScienceSamsung Medical CenterSungkyunkwan University School of MedicineSeoul06351South Korea
| | - Hyo Keun Lim
- Radiology and Center for Imaging ScienceSamsung Medical CenterSungkyunkwan University School of MedicineSeoul06351South Korea
- Department of Health Sciences and TechnologySamsung Advanced Institute for Health Sciences & Technology (SAIHST)Sungkyunkwan University School of MedicineSeoul06355South Korea
| | - Inkyu Park
- Department of Mechanical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141South Korea
| |
Collapse
|
73
|
Ochoa M, Algorri JF, Roldán-Varona P, Rodríguez-Cobo L, López-Higuera JM. Recent Advances in Biomedical Photonic Sensors: A Focus on Optical-Fibre-Based Sensing. SENSORS (BASEL, SWITZERLAND) 2021; 21:6469. [PMID: 34640788 PMCID: PMC8513032 DOI: 10.3390/s21196469] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 09/21/2021] [Accepted: 09/23/2021] [Indexed: 01/22/2023]
Abstract
In this invited review, we provide an overview of the recent advances in biomedical photonic sensors within the last five years. This review is focused on works using optical-fibre technology, employing diverse optical fibres, sensing techniques, and configurations applied in several medical fields. We identified technical innovations and advancements with increased implementations of optical-fibre sensors, multiparameter sensors, and control systems in real applications. Examples of outstanding optical-fibre sensor performances for physical and biochemical parameters are covered, including diverse sensing strategies and fibre-optical probes for integration into medical instruments such as catheters, needles, or endoscopes.
Collapse
Affiliation(s)
- Mario Ochoa
- Photonics Engineering Group, University of Cantabria, 39005 Santander, Spain; (J.F.A.); (P.R.-V.)
- Instituto de Investigación Sanitaria Valdecilla (IDIVAL), 39011 Santander, Spain
| | - José Francisco Algorri
- Photonics Engineering Group, University of Cantabria, 39005 Santander, Spain; (J.F.A.); (P.R.-V.)
- Instituto de Investigación Sanitaria Valdecilla (IDIVAL), 39011 Santander, Spain
| | - Pablo Roldán-Varona
- Photonics Engineering Group, University of Cantabria, 39005 Santander, Spain; (J.F.A.); (P.R.-V.)
- Instituto de Investigación Sanitaria Valdecilla (IDIVAL), 39011 Santander, Spain
- CIBER-bbn, Institute of Health Carlos III, 28029 Madrid, Spain;
| | | | - José Miguel López-Higuera
- Photonics Engineering Group, University of Cantabria, 39005 Santander, Spain; (J.F.A.); (P.R.-V.)
- Instituto de Investigación Sanitaria Valdecilla (IDIVAL), 39011 Santander, Spain
- CIBER-bbn, Institute of Health Carlos III, 28029 Madrid, Spain;
| |
Collapse
|
74
|
Tsutsui K, Kawano D, Mori H, Kato R, Ikeda Y, Sumitomo N, Fukaya H, Iwanaga S, Nakano S, Muramatsu T, Matsumoto K. Characteristics and optimal ablation settings of a novel, contact-force sensing and local impedance-enabled catheter in an ex vivo perfused swine ventricle model. J Cardiovasc Electrophysiol 2021; 32:3187-3194. [PMID: 34559441 DOI: 10.1111/jce.15253] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2021] [Revised: 08/25/2021] [Accepted: 09/18/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Local impedance (LI) has emerged as a new technology that informs on electrical catheter-tissue coupling during radiofrequency (RF) ablation. Recently, IntellaNav StablePoint, a novel LI-enabled catheter that equips contact force (CF) sensing, has been introduced. Although StablePoint and its predecessor IntellaNav MiFi OI share the common technology that reports LI, distinct mechanics for LI sensing between the two products raise a concern that the LI-RF lesion formation relationship may differ. METHODS In an ex vivo swine cardiac tissue model, we investigated the initial level and range of a reduction in LI during a 60-s RF ablation and the resultant lesion characteristics at nine combinations of three energy power (30, 40, and 50 W) and CF (10, 30, and 50 g) steps. Correlations and interactions between CF, LI, wattage, and formed lesions were analyzed. Incidence of achieving LI drop plateau and that of a steam pop were also determined. RESULTS Positive correlations existed between CF and initial LI, CF and absolute/relative LI drop, CF and lesion volume, and LI drop and lesion volume. At the same LI drop, wattage-dependent gain in lesion volume was observed. Steam pops occurred in all CF steps and the prevalence was highest at 50 W. LI drop predicted a steam pop with a cutoff value at 89Ω. CONCLUSION In StablePoint, wattage crucially affects LI drop and lesion volume. Because 30 W ablation may by underpowered for intramural lesion formation and 50 W often resulted in a steam pop, 40 W appears to achieve the balance between the safety and efficacy.
Collapse
Affiliation(s)
- Kenta Tsutsui
- Department of Cardiology, Saitama Medical University International Medical Center, Hidaka, Japan
| | - Daisuke Kawano
- Department of Cardiology, Saitama Medical University International Medical Center, Hidaka, Japan
| | - Hitoshi Mori
- Department of Cardiology, Saitama Medical University International Medical Center, Hidaka, Japan.,Department of Pediatric Cardiology, Saitama Medical University International Medical Center, Hidaka, Japan
| | - Ritsushi Kato
- Department of Cardiology, Saitama Medical University International Medical Center, Hidaka, Japan
| | - Yoshifumi Ikeda
- Department of Cardiology, Saitama Medical University International Medical Center, Hidaka, Japan
| | - Naokata Sumitomo
- Department of Pediatric Cardiology, Saitama Medical University International Medical Center, Hidaka, Japan
| | - Hidehira Fukaya
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Sagamihara, Japan
| | - Shiro Iwanaga
- Department of Cardiology, Saitama Medical University International Medical Center, Hidaka, Japan
| | - Shintaro Nakano
- Department of Cardiology, Saitama Medical University International Medical Center, Hidaka, Japan
| | - Toshihiro Muramatsu
- Department of Cardiology, Saitama Medical University International Medical Center, Hidaka, Japan
| | - Kazuo Matsumoto
- Department of Cardiology, Saitama Medical University International Medical Center, Hidaka, Japan
| |
Collapse
|
75
|
Verma A, Asivatham SJ, Deneke T, Castellvi Q, Neal RE. Primer on Pulsed Electrical Field Ablation: Understanding the Benefits and Limitations. Circ Arrhythm Electrophysiol 2021; 14:e010086. [PMID: 34538095 DOI: 10.1161/circep.121.010086] [Citation(s) in RCA: 107] [Impact Index Per Article: 26.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Pulsed electrical field (PEF) energy is a promising technique for catheter ablation of cardiac arrhythmias. In this article, the key aspects that need to be considered for safe and effective PEF delivery are reviewed, and their impact on clinical feasibility is discussed. The most important benefit of PEF appears to be the ability to kill cells through mechanisms that do not alter stromal proteins, sparing sensitive structures to improve safety, without sacrificing cardiomyocyte ablation efficacy. Many parameters affect PEF treatment outcomes, including pulse intensity, waveform shape, and number of pulses, as well as electrode configuration and geometry. These physical and electrical characteristics must be titrated carefully to balance target tissue effects with collateral implications (muscle contraction, temperature rise, risk of electrical arcing events). It is important to note that any combination of parameters affecting PEF needs to be tested for clinical efficacy and safety. Applying PEF clinically requires knowledge of the fundamentals of this technology to exploit its opportunities and generate viable, durable health improvements for patients.
Collapse
Affiliation(s)
- Atul Verma
- Division of Cardiology, Southlake Regional Health Center, University of Toronto, Newmarket, Canada (A.V.)
| | - Samuel J Asivatham
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (S.J.A.)
| | - Thomas Deneke
- Division of Cardiology, Rhon-Klinikum Campus Bad Neustadt, Bad Neustadt, Germany (T.D.)
| | | | | |
Collapse
|
76
|
Bennett R, Campbell T, Kotake Y, Turnbull S, Bhaskaran A, De Silva K, Lee G, Kalman J, Kumar S. Catheter ablation of idiopathic outflow tract ventricular arrhythmias with low intraprocedural burden guided by pace mapping. Heart Rhythm O2 2021; 2:355-364. [PMID: 34430941 PMCID: PMC8369296 DOI: 10.1016/j.hroo.2021.05.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Background There are limited data comparing ablation outcomes in patients with low intraprocedural burden of ventricular arrhythmias (VA) undergoing a pace mapping (PM)–guided strategy vs those with high burden guided by standard activation mapping strategy (non-PM). Objective We sought to determine if catheter ablation–guided by PM of low-intraprocedural-burden idiopathic outflow tract VA would be noninferior compared to non-PM-guided ablation. Methods Outcomes of catheter ablation of idiopathic outflow tract VA in 22 patients with a low burden of intraprocedural VA using PM-guided ablation were compared to 44 patients with a high burden of intraprocedural VA undergoing ablation using standard techniques. Results Sixty-six patients were included (age 46.5 ± 14.8 years; 68% female, left ventricular ejection fraction 59% ± 5%). Within the PM group, 24-hour preprocedure premature ventricular complex (PVC) burden was 9.5% (interquartile range [IQR] 4%–13.8%), number of pace maps 33.6 ± 18.5, surface area of ≥95% pace map correlation 1.9 ± 1.2 cm2, with best pace map correlation 96% (IQR 92%–97%). Within the non-PM group, 24-hour preprocedure PVC burden was 13.5% (IQR 6.6%–30%), earliest activation time -33.7 ± 9.9 ms. Procedural duration, general anesthesia administration, fluoroscopy dose, and complications were all comparable. Following final procedure, 24-hour VA burden (PM 0% [IQR 0–2.4%] vs non-PM 0% [IQR 0–4.2%], P = .98), along with VA-free survival at 6-month follow-up (PM 77% vs non-PM 71%, P = .77), were both comparable. Conclusion In patients with low intraprocedural burden of outflow tract VA, PM-guided catheter ablation can accurately identify the VA site of origin, leading to outcomes comparable to those achieved with standard ablation techniques.
Collapse
Affiliation(s)
- Richard Bennett
- Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, Westmead, Australia
| | - Timothy Campbell
- Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, Westmead, Australia
| | - Yasuhito Kotake
- Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, Westmead, Australia
| | - Samual Turnbull
- Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, Westmead, Australia
| | - Ashwin Bhaskaran
- Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, Westmead, Australia
| | - Kasun De Silva
- Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, Westmead, Australia
| | - Geoffrey Lee
- Department of Cardiology, The Royal Melbourne Hospital, University of Melbourne, Victoria, Australia
| | - Jonathan Kalman
- Department of Cardiology, The Royal Melbourne Hospital, University of Melbourne, Victoria, Australia
| | - Saurabh Kumar
- Department of Cardiology, Westmead Hospital, Westmead Applied Research Centre, University of Sydney, Westmead, Australia
| |
Collapse
|
77
|
Viola G, Stabile G, Bandino S, Rossi L, Marrazzo N, Pecora D, Bottoni N, Solimene F, Schillaci V, Scaglione M, Ocello S, Baiocchi C, Santoro A, Donzelli S, De Ruvo E, Lavalle C, Sanchez-Gomez JM, Pastor JFA, Grandio PC, Ferraris F, Castro A, Rebellato L, Marchese P, Adao L, Primo J, Barra S, Casu G. Safety, efficacy, and reproducibility of cavotricuspid isthmus ablation guided by the ablation index: acute results of the FLAI study. Europace 2021; 23:264-270. [PMID: 33212484 DOI: 10.1093/europace/euaa215] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Accepted: 07/06/2020] [Indexed: 11/14/2022] Open
Abstract
AIMS Ablation index (AI) is a marker of lesion quality during catheter ablation that incorporates contact force, time, and power in a weighted formula. This index was originally developed for pulmonary vein isolation as well as other left atrial procedures. The aim of our study is to evaluate the feasibility and efficacy of the AI for the ablation of the cavotricuspid isthmus (CTI) in patients presenting with typical atrial flutter (AFL). METHODS AND RESULTS This prospective multicentre non-randomized study enrolled 412 consecutive patients with typical AFL undergoing AI-guided cavotricuspid isthmus ablation. The procedure was performed targeting an AI of 500 and an inter-lesion distance measurement of ≤6 mm. The primary endpoints were CTI 'first-pass' block and persistent block after a 20-min waiting time. Secondary endpoints included procedural and radiofrequency duration and fluoroscopic time. A total of 412 consecutive patients were enrolled in 31 centres (mean age 64.9 ± 9.8; 72.1% males and 27.7% with structural heart disease). The CTI bidirectional 'first-pass' block was reached in 355 patients (88.3%), whereas CTI block at the end of the waiting time was achieved in 405 patients (98.3%). Mean procedural, radiofrequency, and fluoroscopic time were 56.5 ± 28.1, 7.8 ± 4.8, and 1.9 ± 4.8 min, respectively. There were no major procedural complications. There was no significant inter-operator variability in the ability to achieve any of the primary endpoints. CONCLUSION AI-guided ablation with an inter-lesion distance ≤6 mm represents an effective, safe, and highly reproducible strategy to achieve bidirectional block in the treatment of typical AFL.
Collapse
Affiliation(s)
- Graziana Viola
- San Francesco Hospital, Via Mannironi 1, 08100 Nuoro, Italy
| | | | | | - Luca Rossi
- Guglielmo da Saliceto Hospital, Piacenza, Italy
| | | | - Domenico Pecora
- Poliambulanza Foundation Hospital Institute of Brescia, Brescia, Italy
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | - Joao Primo
- Hospital da Luz Arrabida, Vila Nova de Gaia, Portugal
| | - Sergio Barra
- Hospital da Luz Arrabida, Vila Nova de Gaia, Portugal.,Royal Papworth Hospital NHS Trust, Cambridge, UK
| | - Gavino Casu
- San Francesco Hospital, Via Mannironi 1, 08100 Nuoro, Italy.,Department of Biomedical Science, University of Sassari, Sassari, Italy
| |
Collapse
|
78
|
Nogami A, Kurita T, Abe H, Ando K, Ishikawa T, Imai K, Usui A, Okishige K, Kusano K, Kumagai K, Goya M, Kobayashi Y, Shimizu A, Shimizu W, Shoda M, Sumitomo N, Seo Y, Takahashi A, Tada H, Naito S, Nakazato Y, Nishimura T, Nitta T, Niwano S, Hagiwara N, Murakawa Y, Yamane T, Aiba T, Inoue K, Iwasaki Y, Inden Y, Uno K, Ogano M, Kimura M, Sakamoto S, Sasaki S, Satomi K, Shiga T, Suzuki T, Sekiguchi Y, Soejima K, Takagi M, Chinushi M, Nishi N, Noda T, Hachiya H, Mitsuno M, Mitsuhashi T, Miyauchi Y, Miyazaki A, Morimoto T, Yamasaki H, Aizawa Y, Ohe T, Kimura T, Tanemoto K, Tsutsui H, Mitamura H, the JCS/JHRS Joint Working Group. JCS/JHRS 2019 guideline on non-pharmacotherapy of cardiac arrhythmias. J Arrhythm 2021; 37:709-870. [PMID: 34386109 PMCID: PMC8339126 DOI: 10.1002/joa3.12491] [Citation(s) in RCA: 110] [Impact Index Per Article: 27.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
|
79
|
Wintgens LIS, Klaver MN, Maarse M, Spitzer SG, Langbein A, Swaans MJ, Van Dijk VF, Balt JC, Wijffels MCEF, Tijssen JGP, Elvan A, Boersma LVA. Efficacy and safety of the GOLD FORCE multicentre randomized clinical trial: multielectrode phased radiofrequency vs. irrigated radiofrequency single-tip catheter with contact force ablation for treatment of symptomatic paroxysmal atrial fibrillation. Europace 2021; 23:1931-1938. [PMID: 34279627 DOI: 10.1093/europace/euab168] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Accepted: 06/15/2021] [Indexed: 11/14/2022] Open
Abstract
AIMS Pulmonary vein isolation (PVI) for atrial fibrillation (AF) has become increasingly safe and effective with the evolution of single-tip ablation catheters aided by contact force sensing (ST-CF) and single-shot devices such as the second-generation pulmonary vein ablation catheter (PVAC) Gold multi-electrode array. The multicentre randomized GOLD FORCE trial was conducted to evaluate non-inferiority of safety and efficacy of PVAC Gold PVI compared to ST-CF ablation for paroxysmal AF. METHODS AND RESULTS The primary efficacy endpoint documented AF recurrence ≥30 s was assessed by time-to-first-event analysis after a 90-day blanking period using repeated 7-day Holters. Secondary endpoints include acute success and procedural characteristics. Safety endpoints included procedural complications, stroke/transient ischaemic attack (TIA), tamponade, bleeding, and access site complications. Two hundred and eight patients underwent randomization and PVI (103 assigned to PVAC Gold, 105 to ST-CF). Acute success rates were 95% and 97% for PVAC Gold and ST-CF, respectively. At 12 months, AF recurrence was observed in 46.6% of the PVAC Gold group and in 26.2% of the ST-CF group [absolute efficacy difference 20.4% (95% confidence interval, CI 7.5-33.2%), hazard ratio 2.05 (95% CI 1.28-3.29), P = 0.003]. PVAC Gold had significantly shorter procedure and ablation times. Complication rates were 5.7% and 4.9% for PVAC Gold and ST-CF, respectively (P = 0.782). CONCLUSION In this multicentre randomized clinical trial, ablation with ST-CF and PVAC Gold ablation catheters non-inferiority for efficacy was not met. AF recurrence was significantly more frequent in the PVAC Gold group compared to single-tip contact force group. Both groups had similarly low rates of adverse events. PVAC Gold ablation had significantly shorter procedure and ablation times.
Collapse
Affiliation(s)
- Lisette I S Wintgens
- St. Antonius Hospital, Department of Cardiology , Koekoekslaan 1, 3435 Nieuwegein, the Netherlands
| | - Martijn N Klaver
- St. Antonius Hospital, Department of Cardiology , Koekoekslaan 1, 3435 Nieuwegein, the Netherlands
| | - Moniek Maarse
- St. Antonius Hospital, Department of Cardiology , Koekoekslaan 1, 3435 Nieuwegein, the Netherlands
| | - Stefan G Spitzer
- Praxisklinik Herz und Gefäße Dresden, Akademische Lehrpraxisklinik der TU Dresden, Department of Cardiology, Dresden, Germany.,Brandenburg University of Technology Cottbus-Senftenberg, Institute of Medical Technology, Department of Cardiology, Cottbus, Germany
| | - Anke Langbein
- Praxisklinik Herz und Gefäße Dresden, Akademische Lehrpraxisklinik der TU Dresden, Department of Cardiology, Dresden, Germany
| | - Martin J Swaans
- St. Antonius Hospital, Department of Cardiology , Koekoekslaan 1, 3435 Nieuwegein, the Netherlands
| | - Vincent F Van Dijk
- St. Antonius Hospital, Department of Cardiology , Koekoekslaan 1, 3435 Nieuwegein, the Netherlands
| | - Jippe C Balt
- St. Antonius Hospital, Department of Cardiology , Koekoekslaan 1, 3435 Nieuwegein, the Netherlands
| | - Maurits C E F Wijffels
- St. Antonius Hospital, Department of Cardiology , Koekoekslaan 1, 3435 Nieuwegein, the Netherlands
| | - Jan G P Tijssen
- Amsterdam UMC, Department of Cardiology, Amsterdam, the Netherlands
| | - Arif Elvan
- Isala Clinics, Department of Cardiology, Zwolle, the Netherlands
| | - Lucas V A Boersma
- St. Antonius Hospital, Department of Cardiology , Koekoekslaan 1, 3435 Nieuwegein, the Netherlands.,Amsterdam UMC, Department of Cardiology, Amsterdam, the Netherlands
| |
Collapse
|
80
|
Kawano D, Mori H, Kato R, Tsutsui K, Ikeda Y, Sumitomo N, Fukaya H, Iwagana S, Nakano S, Muramatsu T, Matsumoto K. The optimal ablation setting for a local impedance guided catheter in an in vitro experimental model. J Cardiovasc Electrophysiol 2021; 32:2069-2076. [PMID: 34185348 DOI: 10.1111/jce.15136] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 05/20/2021] [Accepted: 06/07/2021] [Indexed: 01/09/2023]
Abstract
BACKGROUND The local impedance (LI) reflects the electrical catheter-tissue coupling and correlates with the local tissue temperature. However, there have been few clinical studies showing the recommended method for LI monitoring catheters. This study aimed to investigate the optimal ablation setting for this catheter in an in vitro experimental model. METHODS LI monitoring catheters were used in an excised swine heart experimental model. The tissue contact force (CF) was directly monitored from an external weight scale. Radiofrequency ablation was performed with a combination of various energy power settings (30, 40, and 50 W), and various CFs (10, 30, and 50 g) for 60 s. The correlation between the LI-related indexes, power, and CF with the lesion formation was statistically analyzed. RESULTS A positive correlation between the LI or lesion formation and CF was observed under all powers. Although the LI drop always correlated with the maximum lesion depth, lesion diameter, and lesion volume, the coefficient of the correlation value was lower under a high CF (lesion depth, diameter, and volume; 10 g, r = 0.8064, r = 0.8389, r = 0.8477; 30 g, r = 0.7590, r = 0.8063, r = 0.8060; 50 g r = 0.5555, r = 0.5701, and r = 0.5678, respectively). Steam pops occurred only under a 50 W ablation and the LI drop cutoff value for steam pops was 46 Ω. CONCLUSION The same LI drop did not always lead to the same lesion size when the CF differed. Monitoring the LI and not exceeding 46 Ω would be useful for a safe ablation.
Collapse
Affiliation(s)
- Daisuke Kawano
- Department of Cardiology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Hitoshi Mori
- Department of Cardiology, Saitama Medical University International Medical Center, Saitama, Japan.,Department of Pediatric Cardiology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Ritsushi Kato
- Department of Cardiology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Kenta Tsutsui
- Department of Cardiology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Yoshifumi Ikeda
- Department of Cardiology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Naokata Sumitomo
- Department of Pediatric Cardiology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Hidehira Fukaya
- Department of Cardiovascular Medicine, Kitasato University School of Medicine, Tokyo, Japan
| | - Shiro Iwagana
- Department of Cardiology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Shintaro Nakano
- Department of Cardiology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Toshihiro Muramatsu
- Department of Cardiology, Saitama Medical University International Medical Center, Saitama, Japan
| | - Kazuo Matsumoto
- Department of Cardiology, Saitama Medical University International Medical Center, Saitama, Japan
| |
Collapse
|
81
|
Takigawa M, Goya M, Iwakawa H, Martin CA, Anzai T, Takahashi K, Kamata T, Matsumura Y, Amemiya M, Yamamoto T, Hirao T, Sekigawa M, Shirai Y, Tao S, Takahashi Y, Sasano T. Impact of a formula combining local impedance and conventional parameters on lesion size prediction. J Interv Card Electrophysiol 2021; 63:389-398. [PMID: 34156611 DOI: 10.1007/s10840-021-01013-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Accepted: 05/23/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND Although ablation energy (AE) and force-time integral (FTI) are well-known active predictors of lesion characteristics, these parameters do not reflect passive tissue reactions during ablation, which may instead be represented by drops in local impedance (LI). This study aimed to investigate if additional LI data improves predicting lesion characteristics and steam pops. METHODS RF applications at a range of powers (30 W, 40 W, and 50 W), contact forces (8 g, 15 g, 25 g, and 35 g), and durations (10-180 s) using perpendicular/parallel catheter orientations were performed in excised porcine hearts (N = 30). The correlation between AE, FTI, and lesion characteristics was examined, and the impact of LI (%LI drop (%LID) defined by the ΔLI divided by the initial LI) was additionally assessed. RESULTS Three hundred seventy-five lesions without steam pops were examined. Ablation energy (W × s) and FTI (g × s) showed a positive correlation with lesion depth (ρ = 0.824:P < 0.0001 and ρ = 0.708:P < 0.0001), surface area (ρ = 0.507:P < 0.0001 and ρ = 0.562:P < 0.0001), and volume (ρ = 0.807:P < 0.0001 and ρ = 0.685:P < 0.0001). %LID also showed a positive correlation individually with lesion depth (ρ = 0.643:P < 0.0001), surface area (ρ = 0.547:P < 0.0001), and volume (ρ = 0.733:P < 0.0001). However, the combined indices of AE × %LID (AE multiplied by %LID) and FTI × %LID (FTI multiplied by %LID) provided significantly stronger correlation with lesion depth (ρ = 0.834:P < 0.0001 and ρ = 0.809:P < 0.0001), surface area (ρ = 0.529:P < 0.0001 and ρ = 0.656:P < 0.0001), and volume (ρ = 0.864:P < 0.0001 and ρ = 0.838:P < 0.0001). This tendency was observed regardless of the catheter placement (parallel/perpendicular). AE (P = 0.02) and %LID (P = 0.002) independently remained as significant predictors to predict steam pops (N = 27). However, the AE × %LID did not increase the predictive power of steam pops compared to the AE alone. CONCLUSION LI, when combined with conventional parameters (AE and FTI), may provide stronger correlation with lesion characteristics.
Collapse
Affiliation(s)
- Masateru Takigawa
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, Japan.
- Department of Advanced Arrhythmia Research, Tokyo Medical and Dental University, Tokyo, Japan.
| | - Masahiko Goya
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, Japan
| | - Hidehiro Iwakawa
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, Japan
- Department of Cardiovascular Medicine, Graduate School of Medicine, Akita University, Akita, Japan
| | | | - Tatsuhiko Anzai
- Department of Biostatistics M&D Data Science Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Kunihiko Takahashi
- Department of Biostatistics M&D Data Science Center, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tatsuaki Kamata
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, Japan
| | - Yu Matsumura
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, Japan
| | - Miki Amemiya
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, Japan
| | - Tasuku Yamamoto
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, Japan
| | - Tatsuhiko Hirao
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, Japan
| | - Masahiro Sekigawa
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, Japan
| | - Yasuhiro Shirai
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, Japan
| | - Susumu Tao
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, Japan
| | - Yoshihide Takahashi
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, Japan
- Department of Advanced Arrhythmia Research, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tetsuo Sasano
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, Japan
| |
Collapse
|
82
|
Nakagawa H, Ikeda A, Sharma T, Govari A, Ashton J, Maffre J, Lifshitz A, Fuimaono K, Yokoyama K, Wittkampf FHM, Jackman WM. Comparison of In Vivo Tissue Temperature Profile and Lesion Geometry for Radiofrequency Ablation With High Power-Short Duration and Moderate Power-Moderate Duration: Effects of Thermal Latency and Contact Force on Lesion Formation. Circ Arrhythm Electrophysiol 2021; 14:e009899. [PMID: 34138641 DOI: 10.1161/circep.121.009899] [Citation(s) in RCA: 89] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
[Figure: see text].
Collapse
Affiliation(s)
- Hiroshi Nakagawa
- Heart Rhythm Institute, Department of Medicine, University of Oklahoma Health Sciences Center (H.N., A.I., W.M.J.)
| | - Atsushi Ikeda
- Heart Rhythm Institute, Department of Medicine, University of Oklahoma Health Sciences Center (H.N., A.I., W.M.J.).,Department of Medicine, Nihon University School of Medicine, Tokyo, Japan (A.I., K.Y.)
| | - Tushar Sharma
- Biosense Webster, Irwindale, CA (T.S., J.A., J.M., A.L., K.F.)
| | | | - John Ashton
- Biosense Webster, Irwindale, CA (T.S., J.A., J.M., A.L., K.F.)
| | - Jennifer Maffre
- Biosense Webster, Irwindale, CA (T.S., J.A., J.M., A.L., K.F.)
| | | | | | - Katsuaki Yokoyama
- Department of Medicine, Nihon University School of Medicine, Tokyo, Japan (A.I., K.Y.)
| | - Fred H M Wittkampf
- Department of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands (F.H.M.W.)
| | - Warren M Jackman
- Heart Rhythm Institute, Department of Medicine, University of Oklahoma Health Sciences Center (H.N., A.I., W.M.J.)
| |
Collapse
|
83
|
Verma A, Schmidt MM, Lalonde JP, Ramirez DA, Getman MK. Assessing the Relationship of Applied Force and Ablation Duration on Lesion Size Using a Diamond Tip Catheter Ablation System. Circ Arrhythm Electrophysiol 2021; 14:e009541. [PMID: 34138635 PMCID: PMC8294657 DOI: 10.1161/circep.120.009541] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
[Figure: see text].
Collapse
Affiliation(s)
- Atul Verma
- Southlake Regional Health Centre, University of Toronto, Newmarket, ON, Canada (A.V)
| | | | | | | | | |
Collapse
|
84
|
McBride S, Avazzadeh S, Wheatley AM, O’Brien B, Coffey K, Elahi A, O’Halloran M, Quinlan LR. Ablation Modalities for Therapeutic Intervention in Arrhythmia-Related Cardiovascular Disease: Focus on Electroporation. J Clin Med 2021; 10:jcm10122657. [PMID: 34208708 PMCID: PMC8235263 DOI: 10.3390/jcm10122657] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 06/13/2021] [Accepted: 06/14/2021] [Indexed: 02/06/2023] Open
Abstract
Targeted cellular ablation is being increasingly used in the treatment of arrhythmias and structural heart disease. Catheter-based ablation for atrial fibrillation (AF) is considered a safe and effective approach for patients who are medication refractory. Electroporation (EPo) employs electrical energy to disrupt cell membranes which has a minimally thermal effect. The nanopores that arise from EPo can be temporary or permanent. Reversible electroporation is transitory in nature and cell viability is maintained, whereas irreversible electroporation causes permanent pore formation, leading to loss of cellular homeostasis and cell death. Several studies report that EPo displays a degree of specificity in terms of the lethal threshold required to induce cell death in different tissues. However, significantly more research is required to scope the profile of EPo thresholds for specific cell types within complex tissues. Irreversible electroporation (IRE) as an ablative approach appears to overcome the significant negative effects associated with thermal based techniques, particularly collateral damage to surrounding structures. With further fine-tuning of parameters and longer and larger clinical trials, EPo may lead the way of adapting a safer and efficient ablation modality for the treatment of persistent AF.
Collapse
Affiliation(s)
- Shauna McBride
- Physiology and Cellular Physiology Laboratory, CÚRAM SFI Centre for Research in Medical Devices, School of Medicine, Human Biology Building, National University of Ireland (NUI) Galway, H91 W5P7 Galway, Ireland; (S.M.); (S.A.); (A.M.W.)
| | - Sahar Avazzadeh
- Physiology and Cellular Physiology Laboratory, CÚRAM SFI Centre for Research in Medical Devices, School of Medicine, Human Biology Building, National University of Ireland (NUI) Galway, H91 W5P7 Galway, Ireland; (S.M.); (S.A.); (A.M.W.)
| | - Antony M. Wheatley
- Physiology and Cellular Physiology Laboratory, CÚRAM SFI Centre for Research in Medical Devices, School of Medicine, Human Biology Building, National University of Ireland (NUI) Galway, H91 W5P7 Galway, Ireland; (S.M.); (S.A.); (A.M.W.)
| | - Barry O’Brien
- AtriAN Medical Limited, Unit 204, NUIG Business Innovation Centre, Upper Newcastle, H91 R6W6 Galway, Ireland; (B.O.); (K.C.)
| | - Ken Coffey
- AtriAN Medical Limited, Unit 204, NUIG Business Innovation Centre, Upper Newcastle, H91 R6W6 Galway, Ireland; (B.O.); (K.C.)
| | - Adnan Elahi
- Translational Medical Device Lab (TMDL), Lamb Translational Research Facility, University College Hospital Galway, H91 V4AY Galway, Ireland; (A.E.); (M.O.)
- Electrical & Electronic Engineering, School of Engineering, National University of Ireland Galway, H91 HX31 Galway, Ireland
| | - Martin O’Halloran
- Translational Medical Device Lab (TMDL), Lamb Translational Research Facility, University College Hospital Galway, H91 V4AY Galway, Ireland; (A.E.); (M.O.)
| | - Leo R. Quinlan
- Physiology and Cellular Physiology Laboratory, CÚRAM SFI Centre for Research in Medical Devices, School of Medicine, Human Biology Building, National University of Ireland (NUI) Galway, H91 W5P7 Galway, Ireland; (S.M.); (S.A.); (A.M.W.)
- CÚRAM, SFI Research Centre for Medical Devices, National University of Ireland Galway, H92 W2TY Galway, Ireland
- Correspondence:
| |
Collapse
|
85
|
Catheter ablation via the left atrium for atrioventricular nodal reentrant tachycardia: A narrative review. Heart Rhythm O2 2021; 2:187-200. [PMID: 34113921 PMCID: PMC8183875 DOI: 10.1016/j.hroo.2021.01.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Background Since 1996, it has been recognized that catheter ablation for atrioventricular nodal reentrant tachycardia (AVNRT) may require an approach through the left atrium. Objective The purposes are to present a case report and to provide a comprehensive narrative review on this topic. Methods A literature review of all articles that provided detailed information on patients who underwent catheter ablation via the left atrium for AVNRT was performed. The primary search queried PubMed using Medical Subject Headings (MeSH) terms "atrioventricular nodal reentrant tachycardia" and "left." The secondary search was performed by manual review of reference lists and Google Scholar citations of manuscripts retrieved by the primary search. The review was limited to the English language. Results The searches yielded 30 articles that described 79 patients. A case report was added. Therefore, the final review consisted of 80 patients. The prevalence of left atrial ablation for patients with AVNRT undergoing catheter ablation at tertiary care centers was approximately 1%. Failed right atrial ablation, with or without coronary sinus ablation, was the most common indication for left atrial ablation. Pooled data from 3 cohort studies estimated the acute success rate for radiofrequency ablation of the slow pathway at the septal or inferoparaseptal segments of the mitral valve annulus after failed right-sided ablation to be 90%. There were no reports of atrioventricular block requiring permanent pacemaker implantation. Conclusion Catheter ablation of the slow pathway via the left atrium is an important technique for AVNRT cases that are refractory to conventional ablation.
Collapse
|
86
|
Nogami A, Kurita T, Abe H, Ando K, Ishikawa T, Imai K, Usui A, Okishige K, Kusano K, Kumagai K, Goya M, Kobayashi Y, Shimizu A, Shimizu W, Shoda M, Sumitomo N, Seo Y, Takahashi A, Tada H, Naito S, Nakazato Y, Nishimura T, Nitta T, Niwano S, Hagiwara N, Murakawa Y, Yamane T, Aiba T, Inoue K, Iwasaki Y, Inden Y, Uno K, Ogano M, Kimura M, Sakamoto SI, Sasaki S, Satomi K, Shiga T, Suzuki T, Sekiguchi Y, Soejima K, Takagi M, Chinushi M, Nishi N, Noda T, Hachiya H, Mitsuno M, Mitsuhashi T, Miyauchi Y, Miyazaki A, Morimoto T, Yamasaki H, Aizawa Y, Ohe T, Kimura T, Tanemoto K, Tsutsui H, Mitamura H. JCS/JHRS 2019 Guideline on Non-Pharmacotherapy of Cardiac Arrhythmias. Circ J 2021; 85:1104-1244. [PMID: 34078838 DOI: 10.1253/circj.cj-20-0637] [Citation(s) in RCA: 90] [Impact Index Per Article: 22.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Akihiko Nogami
- Department of Cardiology, Faculty of Medicine, University of Tsukuba
| | | | - Haruhiko Abe
- Department of Heart Rhythm Management, University of Occupational and Environmental Health, Japan
| | - Kenji Ando
- Department of Cardiology, Kokura Memorial Hospital
| | - Toshiyuki Ishikawa
- Department of Medical Science and Cardiorenal Medicine, Yokohama City University
| | - Katsuhiko Imai
- Department of Cardiovascular Surgery, Kure Medical Center and Chugoku Cancer Center
| | - Akihiko Usui
- Department of Cardiac Surgery, Nagoya University Graduate School of Medicine
| | - Kaoru Okishige
- Department of Cardiology, Yokohama City Minato Red Cross Hospital
| | - Kengo Kusano
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center
| | | | - Masahiko Goya
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | | | | | - Wataru Shimizu
- Department of Cardiovascular Medicine, Graduate School of Medicine, Nippon Medical School
| | - Morio Shoda
- Department of Cardiology, Tokyo Women's Medical University
| | - Naokata Sumitomo
- Department of Pediatric Cardiology, Saitama Medical University International Medical Center
| | - Yoshihiro Seo
- Department of Cardiology, Faculty of Medicine, University of Tsukuba
| | | | - Hiroshi Tada
- Department of Cardiovascular Medicine, Faculty of Medical Sciences, University of Fukui
| | | | - Yuji Nakazato
- Department of Cardiovascular Medicine, Juntendo University Urayasu Hospital
| | - Takashi Nishimura
- Department of Cardiac Surgery, Tokyo Metropolitan Geriatric Hospital
| | - Takashi Nitta
- Department of Cardiovascular Surgery, Nippon Medical School
| | - Shinichi Niwano
- Department of Cardiovascular Medicine, Kitasato University School of Medicine
| | | | - Yuji Murakawa
- Fourth Department of Internal Medicine, Teikyo University Hospital Mizonokuchi
| | - Teiichi Yamane
- Department of Cardiology, Jikei University School of Medicine
| | - Takeshi Aiba
- Division of Arrhythmia, Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center
| | - Koichi Inoue
- Division of Arrhythmia, Cardiovascular Center, Sakurabashi Watanabe Hospital
| | - Yuki Iwasaki
- Department of Cardiovascular Medicine, Graduate School of Medicine, Nippon Medical School
| | - Yasuya Inden
- Department of Cardiology, Nagoya University Graduate School of Medicine
| | - Kikuya Uno
- Arrhythmia Center, Chiba Nishi General Hospital
| | - Michio Ogano
- Department of Cardiovascular Medicine, Shizuoka Medical Center
| | - Masaomi Kimura
- Advanced Management of Cardiac Arrhythmias, Hirosaki University Graduate School of Medicine
| | | | - Shingo Sasaki
- Department of Cardiology and Nephrology, Hirosaki University Graduate School of Medicine
| | | | - Tsuyoshi Shiga
- Department of Cardiology, Tokyo Women's Medical University
| | - Tsugutoshi Suzuki
- Departments of Pediatric Electrophysiology, Osaka City General Hospital
| | - Yukio Sekiguchi
- Department of Cardiology, Faculty of Medicine, University of Tsukuba
| | - Kyoko Soejima
- Arrhythmia Center, Second Department of Internal Medicine, Kyorin University Hospital
| | - Masahiko Takagi
- Division of Cardiac Arrhythmia, Department of Internal Medicine II, Kansai Medical University
| | - Masaomi Chinushi
- School of Health Sciences, Faculty of Medicine, Niigata University
| | - Nobuhiro Nishi
- Department of Cardiovascular Therapeutics, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
| | - Takashi Noda
- Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center
| | - Hitoshi Hachiya
- Department of Cardiovascular Medicine, Tsuchiura Kyodo General Hospital
| | | | | | - Yasushi Miyauchi
- Department of Cardiovascular Medicine, Nippon Medical School Chiba-Hokusoh Hospital
| | - Aya Miyazaki
- Department of Pediatric Cardiology, Congenital Heart Disease Center, Tenri Hospital
| | - Tomoshige Morimoto
- Department of Thoracic and Cardiovascular Surgery, Osaka Medical College
| | - Hiro Yamasaki
- Department of Cardiology, Faculty of Medicine, University of Tsukuba
| | | | | | - Takeshi Kimura
- Department of Cardiology, Graduate School of Medicine and Faculty of Medicine, Kyoto University
| | - Kazuo Tanemoto
- Department of Cardiovascular Surgery, Kawasaki Medical School
| | | | | | | |
Collapse
|
87
|
Kanagasundram A, Richardson TD, Stevenson WG. Tissue coverage matters. J Cardiovasc Electrophysiol 2021; 32:1600-1601. [PMID: 33928705 DOI: 10.1111/jce.15055] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 04/23/2021] [Indexed: 12/01/2022]
Affiliation(s)
- Arvindh Kanagasundram
- Arrhythmia Section, Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Travis D Richardson
- Arrhythmia Section, Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - William G Stevenson
- Arrhythmia Section, Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| |
Collapse
|
88
|
Bourier F, Popa M, Kottmaier M, Maurer S, Bahlke F, Telishevska M, Lengauer S, Koch-Büttner K, Kornmayer M, Risse E, Brkic A, Reents T, Hessling G, Deisenhofer I. RF electrode-tissue coverage significantly influences steam pop incidence and lesion size. J Cardiovasc Electrophysiol 2021; 32:1594-1599. [PMID: 33928696 DOI: 10.1111/jce.15063] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 03/04/2021] [Accepted: 03/16/2021] [Indexed: 01/18/2023]
Abstract
BACKGROUND Steam pops are a rare complication associated with radiofrequency (RF) ablation and are hard to predict. The aim of this study was to assess the influence of coverage between the RF ablation electrode and cardiac tissue on steam pop incidence and lesion size. METHODS AND RESULTS An ex vivo model using porcine cardiac preparations and contact force sensing catheters was designed to perform RF ablations at different coverage levels between the RF electrode and cardiac tissue. During coverage level I, only the distal part of the ablation electrode was in contact with tissue. During coverage level II half of the ablation electrode, and during coverage level III the entire ablation electrode was embedded in tissue. RF applications (n = 60) at different coverage levels I-III were systematically performed using the same standardized ablation protocol. Ablations during coverage level III resulted in a significantly higher rate of steam pops (100%) when compared to ablations during coverage level II (10%) and coverage level I (0%), log rank p < .001. Coverage level I ablations resulted in significantly smaller lesion depths, diameters, and impedance drops when compared to higher coverage level ablations, p < .001. In the controlled ex vivo model, there was no difference in applied contact force or energy between different coverage levels. CONCLUSIONS The level of coverage between RF electrode, cardiac tissue, and the surrounding fluid significantly influenced the incidence of steam pops in an ex vivo setup. Larger coverage between RF electrode and tissue resulted in significantly larger lesion dimensions.
Collapse
Affiliation(s)
- Felix Bourier
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Miruna Popa
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Marc Kottmaier
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Susanne Maurer
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Fabian Bahlke
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Marta Telishevska
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Sarah Lengauer
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Katharina Koch-Büttner
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Marielouise Kornmayer
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Elena Risse
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Amir Brkic
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Tilko Reents
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Gabriele Hessling
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Isabel Deisenhofer
- Department of Electrophysiology, German Heart Center Munich, Technical University Munich, Munich, Germany
| |
Collapse
|
89
|
Cheng W, Yao M, Zhai B, Wang P. Contact force sensors in minimally invasive catheters: current and future applications. Expert Rev Med Devices 2021; 18:445-455. [PMID: 33886427 DOI: 10.1080/17434440.2021.1917372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
INTRODUCTION Advances in catheter design for minimally invasive surgery have brought about the incorporation of contact force (CF) sensors in catheters. Two main approaches to achieve CF sensing at the catheter end-effector consist of fiber optic or magnetic solutions. CF sensing feedback can be used to assist in ablation procedures, mapping cardiac regions, identifying tissue characteristics, and enhancing robotic catheter control. AREAS COVERED This review covers the technological and clinical aspects of CFS in catheters. Contact force and force-time integral thresholds for ablation procedures, procedural complications, and electroanatomical mapping strategies are discussed. Future applications of improving catheter control, minimizing complications, and enhancing mapping techniques through CF are examined. EXPERT OPINION Fiber optic CF catheters may be more desirable compared to magnetic modalities due to the lower cost, compactness, and higher accuracy. In ablation procedures, complications due to higher ablation duration, power, contact force, and force time can be reduced through practical experience and informed training for catheter operators. Future prospects consist of the incorporation of CF sensors with remote catheter systems to assist in catheter control. We propose that CF can also be used in machine learning decision-making algorithms to prevent complications or improve tissue characterization.
Collapse
Affiliation(s)
- Weyland Cheng
- Department of Orthopaedic Surgery, Children's Hospital Affiliated to Zhengzhou University, Henan Children's Hospital, Zhengzhou Children's Hospital, Zhengzhou, Henan, China.,Henan Provincial Key Laboratory of Children's Genetics and Metabolic Diseases, Children's Hospital Affiliated to Zhengzhou University, Henan Children's Hospital, Zhengzhou Children's Hospital, Zhengzhou, Henan, China
| | - Manye Yao
- Department of Orthopaedic Surgery, Children's Hospital Affiliated to Zhengzhou University, Henan Children's Hospital, Zhengzhou Children's Hospital, Zhengzhou, Henan, China
| | - Bo Zhai
- Department of Cardiothoracic Surgery, Children's Hospital Affiliated to Zhengzhou University, Henan Children's Hospital, Zhengzhou Children's Hospital, Zhengzhou, Henan, China
| | - Penggao Wang
- Department of Cardiothoracic Surgery, Children's Hospital Affiliated to Zhengzhou University, Henan Children's Hospital, Zhengzhou Children's Hospital, Zhengzhou, Henan, China
| |
Collapse
|
90
|
Blandino A, Bianchi F, Sibona Masi A, Mazzanti A, D'Ascenzo F, Grossi S, Musumeci G. Outcomes of manual versus remote magnetic navigation for catheter ablation of ventricular tachycardia: a systematic review and updated meta-analysis. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2021; 44:1102-1114. [PMID: 33825206 DOI: 10.1111/pace.14231] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 02/08/2021] [Accepted: 03/21/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE Ventricular tachycardia (VT) ablation is a complex procedure that requires remarkable catheter manipulation skill, great mapping accuracy and catheter stability, and can expose patients to serious complications. Magnetic navigation system (RMN)-guided ablation and contact force-sensing (CFS) catheters have the potential to overcome these obstacles. We performed a systematic review and updated meta-analysis of all available studies evaluating the outcomes of VT ablation by using RMN-guided compared to manual navigation (MAN)-guided, with and without CFS catheters. METHODS MEDLINE/PubMed, Cochrane, and Google Scholar were searched for randomized controlled trials (RCT) or observational studies with multivariate adjustment comparing RMN-guided versus MAN-guided VT ablation. RESULTS Thirteen studies enrolling 1348 patients (656 RMN-guided vs. 692 MAN-guided) were included. CFS catheter were used in 14% of MAN-guided patients. In comparison to MAN-guided and CFS-guided, RMN-guided VT ablation was associated with a significant higher acute ablation success (OR 2.32, 1.66-3.23 and OR 2.91, 1.29-6.53, respectively) but similar results in term of long-term VT recurrence (OR 0.75, 0.56-1.01 and OR 0.79, 0.27-2.36, respectively). RMN-guided showed a better safety profile (for all complications, OR 0.52, 0.34-0.81) and allowed a significant x-ray reduction compared to MAN-guided (OR 0.21, 0.14-0.32) and CFS-guided VT ablation (OR 0.23, 0.11-0.52, all 95% CI). CONCLUSIONS RMN-guided was superior to MAN-guided and CFS-guided VT ablation in term of acute ablation success, all complications endpoint, and reduction of fluoroscopy exposure, but did not reduce long-term VT recurrence. Large prospective multicenter randomized trials are needed to confirm these findings.
Collapse
Affiliation(s)
| | | | | | - Andrea Mazzanti
- Molecular Cardiology, Istituti Clinici Scientifici Maugeri, Istituto di Ricovero e Cura a Carattere Scientifico, Pavia, Italy.,Department of Molecular Medicine, University of Pavia, Pavia, Italy
| | - Fabrizio D'Ascenzo
- Division of Cardiology, Department of Medical Sciences, AOU Città della Salute e della Scienza, University of Turin, Turin, Italy
| | - Stefano Grossi
- Division of Cardiology, Mauriziano Umberto I Hospital, Turin, Italy
| | | |
Collapse
|
91
|
Maclean E, Simon R, Ang R, Dhillon G, Ahsan S, Khan F, Earley M, Lambiase PD, Rosengarten J, Chow AW, Dhinoja M, Providencia R, Markides V, Wong T, Hunter RJ, Behar JM. A multi-center experience of ablation index for evaluating lesion delivery in typical atrial flutter. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2021; 44:1039-1046. [PMID: 33782987 DOI: 10.1111/pace.14228] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 02/18/2021] [Accepted: 03/21/2021] [Indexed: 12/20/2022]
Abstract
BACKGROUND Anatomical studies demonstrate significant variation in cavotricuspid isthmus (CTI) architecture. METHODS Thirty-eight patients underwent CTI ablation at two tertiary centers. Operators delivered 682 lesions with a target ablation index (AI) of 600 Wgs. Ablation parameters were recorded every 10-20 ms. Post hoc, Visitags were trisected according to CTI position: inferior vena cava (IVC), middle (Mid), or ventricular (V) lesions. RESULTS There were no complications. 92.1% of patients (n = 35) remained in sinus rhythm after 14.6 ± 3.4 months. For the whole CTI, peak AI correlated with mean impedance drop (ID) (R2 = 0.89, p < .0001). However, analysis by anatomical site demonstrated a non-linear relationship Mid CTI (R2 = 0.15, p = .21). Accordingly, while mean AI was highest Mid CTI (IVC: 473.1 ± 122.1 Wgs, Mid: 539.6 ± 103.5 Wgs, V: 486.2 ± 111.8 Wgs, ANOVA p < .0001), mean ID was lower (IVC: 10.7 ± 7.5Ω, Mid: 9.0 ± 6.5Ω, V: 10.9 ± 7.3Ω, p = .011), and rate of ID was slower (IVC: 0.37 ± 0.05 Ω/s, Mid: 0.18 ± 0.08 Ω/s, V: 0.29 ± 0.06 Ω/s, p < .0001). Mean contact force was similar at all sites; however, temporal fluctuations in contact force (IVC: 19.3 ± 12.0 mg/s, Mid: 188.8 ± 92.1 mg/s, V: 102.8 ± 32.3 mg/s, p < .0001) and catheter angle (IVC: 0.42°/s, Mid: 3.4°/s, V: 0.28°/s, p < .0001) were greatest Mid CTI. Use of a long sheath attenuated these fluctuations and improved energy delivery. CONCLUSIONS Ablation characteristics vary across the CTI. At the Mid CTI, higher AI values do not necessarily deliver more effective ablation; this may reflect localized fluctuations in catheter angle and contact force.
Collapse
Affiliation(s)
- Edd Maclean
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK.,William Harvey Research Institute, Queen Mary University of London, London, UK
| | - Ron Simon
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK
| | - Richard Ang
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK
| | - Gurpreet Dhillon
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK
| | - Syed Ahsan
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK
| | - Fakhar Khan
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK
| | - Mark Earley
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK
| | - Pier D Lambiase
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK
| | - James Rosengarten
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK
| | - Anthony W Chow
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK
| | - Mehul Dhinoja
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK
| | - Rui Providencia
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK
| | - Vias Markides
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK
| | - Tom Wong
- Department of Cardiac Electrophysiology, Royal Brompton Hospital, London, UK
| | - Ross J Hunter
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK.,William Harvey Research Institute, Queen Mary University of London, London, UK
| | - Jonathan M Behar
- Department of Cardiac Electrophysiology, St Bartholomew's Hospital, W Smithfield, London, UK.,William Harvey Research Institute, Queen Mary University of London, London, UK.,Department of Cardiac Electrophysiology, Royal Brompton Hospital, London, UK
| |
Collapse
|
92
|
Enomoto Y, Nakamura K, Ishii R, Toyoda Y, Asami M, Takagi T, Hashimoto H, Hara H, Sugi K, Moroi M, Nakamura M. Lesion size and adjacent tissue damage assessment with high power and short duration radiofrequency ablation: comparison to conventional radiofrequency ablation power setting. Heart Vessels 2021; 36:1438-1444. [PMID: 33740089 DOI: 10.1007/s00380-021-01833-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Accepted: 03/12/2021] [Indexed: 10/21/2022]
Abstract
There is increased interest in creating high-power short duration (HPSD) ablation lesions in the field of atrial fibrillation (AF) radiofrequency ablation (RFA). We evaluated the lesion characteristics and collateral damage using two separate RFA protocols setting (HPSD: 50 W and 7 s vs control: 25 W and 30 s) in vitro model. Sixteen freshly killed porcine hearts were obtained, and the atrium and ventricle slabs were harvested for ablation. The each slabs were placed in a tissue bath with circulating 0.9% NaCl at maintained temperature 37 °C. RFA was performed with 4 mm tip irrigated force sensing catheter. All lesions were ablated under recording the electrical parameters using with Ensite Navx system (St. Jude Medical, St. Paul, Minnesota). After RFA, lesion characteristics were assessed for each lesion. Thirty-five lesions were made for each ablation protocol (total 70 lesions for analysis). Ablation parameters were similar between two groups (HPSD vs control; impedance drop (Ω): 34.2 ± 13.1 vs 36.1 ± 8.65 P = 0.49, contact force (g): 13.9 ± 4.37 vs 14.6 ± 5.09, P = 0.51, lesion size index: 4.8 ± 0.52 vs 4.73 ± 0.59, P = 0.62). Although the lesion volume was similar, the HPSD ablation creates wider but more shallower lesions compared to control group (HPSD vs control; lesion volume: 29.6 ± 18.1 mm3 vs 35.5 ± 17.1 mm3 P = 0.16, lesion diameter: 4.98 ± 0.91 mm vs 4.45 ± 0.74 mm P = 0.0095, lesion depth: 2.2 ± 0.76 mm vs 2.8 ± 1.56 mm P = 0.046). Of these, 38 lesions were assessed for adjacent tissue damage and adjacent tissue damages were more frequent seen in control group (HPSD vs control; 1/19 (5.26%) vs 6/19 (31.5%), P = 0.036). Effective lesions were made with HPSD, thereby reducing RFA procedure time. Although the lesion volume was similar between two groups, collateral damage was less seen in HPSD group attributed by lesion characteristics.
Collapse
Affiliation(s)
- Yoshinari Enomoto
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi Meguro-ku, Tokyo, 153-8515, Japan.
| | - Keijiro Nakamura
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi Meguro-ku, Tokyo, 153-8515, Japan
| | - Rina Ishii
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi Meguro-ku, Tokyo, 153-8515, Japan
| | - Yasutake Toyoda
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi Meguro-ku, Tokyo, 153-8515, Japan
| | - Masako Asami
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi Meguro-ku, Tokyo, 153-8515, Japan
| | - Takahito Takagi
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi Meguro-ku, Tokyo, 153-8515, Japan
| | - Hikari Hashimoto
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi Meguro-ku, Tokyo, 153-8515, Japan
| | - Hidehiko Hara
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi Meguro-ku, Tokyo, 153-8515, Japan
| | - Kaoru Sugi
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi Meguro-ku, Tokyo, 153-8515, Japan.,Division of Cardiology, Odawara Cardiovascular Hospital, Tokyo, Japan
| | - Masao Moroi
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi Meguro-ku, Tokyo, 153-8515, Japan
| | - Masato Nakamura
- Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-17-6 Ohashi Meguro-ku, Tokyo, 153-8515, Japan
| |
Collapse
|
93
|
Cui L, Chu Y, Han Y, Dong S. Comparison of higher-power and conventional power ablation of atrial fibrillation using contact force-sensing catheters: a systematic review and meta-analysis. J Interv Card Electrophysiol 2021; 62:1-7. [PMID: 33730302 DOI: 10.1007/s10840-021-00975-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Accepted: 03/07/2021] [Indexed: 01/01/2023]
Abstract
BACKGROUND Contact force-sensing catheters have been widely used in catheter ablation. During the past few decades, more attention has been paid on the technique of high-power ablation. The purpose of this meta-analysis is to compare the efficacy and safety of conventional power and high power on atrial fibrillation radiofrequency ablation by contact force-sensing catheters. METHODS We identified studies through searching MEDLINE, Embase, the Web of Science, Scopus, and the Cochrane Library from inception up until July 2020. The primary outcomes were defined as recurrence of atrial tachyarrhythmia and complications. The secondary outcomes were acute reconnections of pulmonary veins (PVs), ablation time, and the total procedural time. RESULTS Four nonrandomized, observational studies (nROS) were selected involving 231 patients with high-power ablation and 239 patients with conventional power ablation. There were insignificant differences in the recurrence rate of atrial tachyarrhythmia (14.2% versus 20.5%, OR: 0.64, 95%CI: 0.39 to 1.04, Z = 1.82, P = 0.07) and clinical complications (1.7% versus 2.5%, OR: 0.72, 95%CI: 0.21 to 2.47, Z = 0.51, P = 0.61) between high-power and conventional power ablation. However, compared with conventional power group, the high-power group had fewer acute PVs reconnections (P = 0.0001), shorter in ablation time (P < 0.0001), and the total procedural time (P < 0.0001). CONCLUSIONS High-power ablation could not only ablate safely and efficiently but also reduce focal ablation time and total procedural time significantly.
Collapse
Affiliation(s)
- Luqian Cui
- Department of Cardiology, Zhengzhou University People's Hospital, Zhengzhou, China
| | - Yingjie Chu
- Department of Cardiology, Henan Province People's Hospital, Zhengzhou, China.
| | - Yongmei Han
- Department of Cardiology, Zhengzhou University People's Hospital, Zhengzhou, China
| | - Shujuan Dong
- Department of Cardiology, Henan Province People's Hospital, Zhengzhou, China
| |
Collapse
|
94
|
Relationship of Catheter Contact Angle and Contact Force with Contact Area on the Surface of Heart Muscle Tissue in Cardiac Catheter Ablation. Cardiovasc Eng Technol 2021; 12:407-417. [PMID: 33723738 PMCID: PMC8354874 DOI: 10.1007/s13239-021-00529-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Accepted: 02/16/2021] [Indexed: 11/16/2022]
Abstract
Purpose The aims of this study were to develop an experimental procedure for setting the catheter angle with respect to the surface of the heart muscle and the catheter contact force and to investigate the catheter contact area on the heart muscle as a function of catheter contact angle and force. Methods Visualization tests were performed for 5 contact angles (0°, 30°, 45°, 60°, and 90°) and 8 contact forces (2, 4, 6, 10, 15, 20, 30, and 40 gf). Each experiment was repeated 6 times with 2 different commercially available catheter tips. Results The morphology of the contact area was classified into rectangular, circular, ellipsoidal, and semi-ellipsoidal. The correlation between contact force and contact area was a logarithmic function; increasing contact force was associated with increased contact area. At the same contact force, the correlation between contact angle and contact area was inverse; decreasing contact angle was associated with a corresponding increase in contact area. Conclusion Both the catheter contact angle and contact force substantially impact the contact area and morphology in catheter ablation procedures.
Collapse
|
95
|
Hwang YM, Lee WS, Choi KJ, Kim YR. Radiofrequency induced lesion characteristics according to force-time integral in experimental model. Medicine (Baltimore) 2021; 100:e25126. [PMID: 33725912 PMCID: PMC7969321 DOI: 10.1097/md.0000000000025126] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Accepted: 02/16/2021] [Indexed: 01/05/2023] Open
Abstract
Contact force (CF)-sensing technology has enabled accurate real-time CF measurement in tissue. Average CF, which is quantified by the force–time integral (FTI), correlates with lesion volume. Little is known about which of the time and force factors that compose FTI plays a more important role and which is a better index for predicting lesion size, FTI, or force–power–time index (FPTI). Investigators sought to identify a better index for predicting radiofrequency ablation lesion formation with experimental model. Radiofrequency current was delivered to the swine skeletal muscle at radiofrequency energy current was delivered at 4 fixed power settings (15, 25, 30, and 40 W) for 6 variable time durations (5, 10, 20, 30, 40, and 50 s) with 6 variable CF settings (5, 10, 20, 30, 40, and 50 g). At each setting, the following parameters were evaluated: (1).. transmural lesion depth, (2).. lesion width, and (3).. lesion volume. Between FTI factors, the time factor was more important than the force factor for lesion formation. The area under the curve was greater for FPTI (0.943) than for FTI (0.870). On univariate linear regression analysis, the explanatory power of the linear regression model was better explained by FPTI (56.4%) than FTI (32.1%). Under the same FTI condition, the time factor had a greater effect on lesion formation. When power was included, the power factor had a greater effect on lesion formation and steam pop.
Collapse
Affiliation(s)
- You Mi Hwang
- Division of Cardiology, Department of Internal Medicine, St. Vincent's Hospital, The Catholic University of Korea, Seoul, South Korea
| | - Woo Seok Lee
- Division of Cardiology, Department of Internal Medicine, Yeosu Jeil Hospital, Yeosu
| | - Kee-Joon Choi
- Division of Cardiology, Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Yoo Ri Kim
- Division of Cardiology, Department of Internal Medicine, Dongguk University Ilsan Hospital, 10326, 27 Dongguk-ro Ilsandong-gu, Goyang-si, Gyeonggi-do, Korea
| |
Collapse
|
96
|
Bennett R, Turnbull S, Kotake Y, Campbell T, Kumar S. Ventricular Arrhythmia Burden as a Marker of Success Following Catheter Ablation of Ventricular Arrhythmias in Patients with Structural Heart Disease. Korean Circ J 2021; 51:455-468. [PMID: 33764012 PMCID: PMC8112175 DOI: 10.4070/kcj.2020.0415] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 12/09/2020] [Accepted: 01/12/2021] [Indexed: 01/19/2023] Open
Abstract
Background and Objectives There is little emphasis on the efficacy of catheter ablation for ventricular arrhythmia (VA) when using VA burden reduction as a marker for success. We examined the efficacy of catheter ablation using VA burden, rather than VA recurrence as a marker of success, following catheter ablation of structural heart disease (SHD) related VA. Methods Catheter ablation of SHD related VA was performed at a single centre over 4-years. VA episodes and implantable cardioverter defibrillator (ICD) therapies were recorded over the 6-months before and after final ablation. Outcomes were reported in terms of burden reduction and compared to singular VA recurrence. Results Overall, 108 patients were included in the study. Mean age 64.2±13.9 years, 86% male, mean left ventricular ejection fraction (LVEF) 42±16%. Median VA episodes and ICD therapy were significantly reduced after ablation (VA before: 10 [interquartile range, IQR: 2–38] vs. VA after: 0 [IQR: 0–2], p<0.001; anti–tachycardia pacing [ATP] before: 16 (IQR: 1.5–57) vs. ATP after: 0 [IQR: 0–2], p<0.001; shocks before: 1 [IQR: 0–5] vs. shocks after: 0 [IQR: 0–0], p<0.001). Procedural success at 6-months was significantly higher when considering ≥75% reduction in VA burden, rather than a singular VA-free survival (83% vs. 67%, p=0.001). Conclusions The vast majority (>80%) of patients achieve reduction in VA burden (≥75% reduction) after catheter ablation for VA. This data suggests that catheter ablation is highly therapeutic when procedure success is defined as reduction in VA, rather than using a single VA recurrence as a metric for failure.
Collapse
Affiliation(s)
- Richard Bennett
- Department of Cardiology, Westmead Hospital, The University of Sydney, Westmead, Australia
| | - Samual Turnbull
- Department of Cardiology, Westmead Hospital, The University of Sydney, Westmead, Australia
| | - Yasuhito Kotake
- Department of Cardiology, Westmead Hospital, The University of Sydney, Westmead, Australia
| | - Timothy Campbell
- Department of Cardiology, Westmead Hospital, The University of Sydney, Westmead, Australia
| | - Saurabh Kumar
- Department of Cardiology, Westmead Hospital, The University of Sydney, Westmead, Australia.
| |
Collapse
|
97
|
Kumar N, Wirekoh J, Saba S, Riviere CN, Park YL. Soft Miniaturized Actuation and Sensing Units for Dynamic Force Control of Cardiac Ablation Catheters. Soft Robot 2021; 8:59-70. [PMID: 32392453 PMCID: PMC7891206 DOI: 10.1089/soro.2019.0011] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
Recently, there has been active research in finding robotized solutions for the treatment of atrial fibrillation (AF) by augmenting catheter systems through the integration of force sensors at the tip. However, limited research has been aimed at providing automatic force control by also integrating actuation of the catheter tip, which can significantly enhance safety in such procedures. This article solves the demanding challenge of miniaturizing both actuation and sensing for integration into flexible catheters. Fabrication strategies are presented for a series of novel soft thick-walled cylindrical actuators, with embedded sensing using eutectic gallium-indium. The functional catheter tips have a diameter in the range of 2.6-3.6 mm and can both generate and detect forces in the range of < 0.4 N, with a bandwidth of 1-2 Hz. The deformation modeling of thick-walled cylinders with fiber reinforcement is presented in the article. An experimental setup developed for static and dynamic characterization of these units is presented. The prototyped units were validated with respect to the design specifications. The preliminary force control results indicate that these units can be used in tracking and control of contact force, which has the potential to make AF procedures much safer and more accurate.
Collapse
Affiliation(s)
- Nitish Kumar
- Department of Computer Science, ETH Zürich, Zürich, Switzerland
| | | | - Samir Saba
- Department of Cardiac Electrophysiology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Cameron N. Riviere
- Robotics Institute, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA
| | - Yong-Lae Park
- Robotics Institute, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA
- Department of Mechanical Engineering, Institute of Advanced Machines and Design, Institute of Engineering Research, Seoul National University, Seoul, Korea
| |
Collapse
|
98
|
Jankelson L, Dai M, Aizer A, Bernstein S, Park DS, Holmes D, Chinitz LA, Barbhaiya C. Lesion Sequence and Catheter Spatial Stability Affect Lesion Quality Markers in Atrial Fibrillation Ablation. JACC Clin Electrophysiol 2021; 7:367-377. [PMID: 33516716 DOI: 10.1016/j.jacep.2020.09.027] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Revised: 09/03/2020] [Accepted: 09/23/2020] [Indexed: 11/19/2022]
Abstract
OBJECTIVES This study sought to analyze high-frequency catheter excursion in relation to lesion quality markers in 20 consecutive patients undergoing first-time radiofrequency (RF) ablation for paroxysmal atrial fibrillation (AF). BACKGROUND Ablation therapy for AF requires the delivery of durable lesions. The extent to which lesion sequence, catheter spatial stability, and anatomic location influence lesion formation during RF ablation of AF is not well understood. METHODS Three-dimensional spatial excursion of the ablation catheter sampled at 60 Hz during pre-specified pairs of RF lesions was extracted from the CARTO3 System (Biosense Webster Inc., Irvine, California) and analyzed by using custom-developed MATLAB software (MathWorks, Natick, Massachusetts) to define precise catheter spatial stability during RF ablation. Ablation parameters including bipolar electrogram amplitude reduction, impedance decline and transmurality-associated unipolar electrogram (TUE) as evidence of lesion transmurality during lesion placement were recorded and analyzed. RESULTS We collected 437,760 position data points during lesion placement. Ablation catheter spatial stability and lesion formation parameters varied considerably by anatomic location. Lesions placed immediately had similar bipolar electrogram amplitude reduction, smaller impedance decline, but higher likelihood of achieving TUE compared to delayed lesions. Greater catheter spatial stability correlated with lesser impedance decline. CONCLUSIONS Lesion sequence, ablation catheter spatial stability, and anatomic location are important modifiers of RF lesion formation. Lesions placed immediately are more likely to exhibit TUE. Greater ablation catheter stability is associated with lesser impedance decline but greater likelihood of TUE.
Collapse
Affiliation(s)
- Lior Jankelson
- Leon H. Charney Division of Cardiology, New York University Langone Medical Center, New York University School of Medicine, New York, New York, USA.
| | - Matthew Dai
- Leon H. Charney Division of Cardiology, New York University Langone Medical Center, New York University School of Medicine, New York, New York, USA
| | - Anthony Aizer
- Leon H. Charney Division of Cardiology, New York University Langone Medical Center, New York University School of Medicine, New York, New York, USA
| | - Scott Bernstein
- Leon H. Charney Division of Cardiology, New York University Langone Medical Center, New York University School of Medicine, New York, New York, USA
| | - David S Park
- Leon H. Charney Division of Cardiology, New York University Langone Medical Center, New York University School of Medicine, New York, New York, USA
| | - Douglas Holmes
- Leon H. Charney Division of Cardiology, New York University Langone Medical Center, New York University School of Medicine, New York, New York, USA
| | - Larry A Chinitz
- Leon H. Charney Division of Cardiology, New York University Langone Medical Center, New York University School of Medicine, New York, New York, USA
| | - Chirag Barbhaiya
- Leon H. Charney Division of Cardiology, New York University Langone Medical Center, New York University School of Medicine, New York, New York, USA
| |
Collapse
|
99
|
Nakamura K, Sasaki T, Take Y, Minami K, Sasaki W, Kishi S, Yoshimura S, Okazaki Y, Miki Y, Goto K, Kaseno K, Yamashita E, Koyama K, Funabashi N, Naito S. Effect of preventing air intrusion on silent strokes during atrial fibrillation ablation using a mini-basket catheter. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2020; 44:71-81. [PMID: 33216388 DOI: 10.1111/pace.14131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Revised: 11/04/2020] [Accepted: 11/15/2020] [Indexed: 11/28/2022]
Abstract
BACKGROUND Air bubble intrusion through transseptal sheaths during left atrial (LA) catheter ablation can cause cerebral embolisms, especially when using complex-shape catheters. This study aimed to compare the incidence of silent cerebral events (SCEs) after atrial fibrillation (AF) catheter ablation using a mini-basket catheter (IntellaMap Orion; Boston Scientific) between the following groups: group SP, strict prevention of LA air intrusion and group CP, conventional air intrusion prevention. METHODS We enrolled 123 consecutive AF patients (group SP, n = 61 and group CP, n = 62) who underwent brain magnetic resonance imaging after a local-impedance-guided ablation using one mini-basket catheter and one circular mapping catheter. The preventive strategy in group SP included (a) the insertion of the mini-basket catheter into the transseptal sheaths in a container filled with heparinized saline and (b) no exchange of all catheters over the sheaths. RESULTS SCEs were detected in 67 patients (54.5%), and the incidence of SCEs did not significantly differ between groups SP and CP (55.7% vs 53.2%; P = .780). A multivariate analysis demonstrated that an older age, non-paroxysmal AF, and radiofrequency (RF) power output were independent positive predictors of SCEs (odds ratios: 1.079, 5.613, and 1.405; P = .005, <.001, and .012). On the follow-up MR imaging, 83.5% of the SCEs in group SP and 87.7% in group CP disappeared (P = .398). CONCLUSIONS Strict prevention of LA air intrusion may have no additional effect for reducing the incidence of SCEs after local impedance-guided AF ablation using a mini-basket catheter. An older age, non-paroxysmal AF, and high-power RF applications may increase the risk of SCEs.
Collapse
Affiliation(s)
- Kohki Nakamura
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| | - Takehito Sasaki
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| | - Yutaka Take
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| | - Kentaro Minami
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| | - Wataru Sasaki
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| | - Shohei Kishi
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| | - Shingo Yoshimura
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| | - Yoshinori Okazaki
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| | - Yuko Miki
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| | - Koji Goto
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| | - Kenichi Kaseno
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| | - Eiji Yamashita
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| | - Keiko Koyama
- Division of Radiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| | - Nobusada Funabashi
- Department of Cardiovascular Science and Medicine, Chiba University Graduate School of Medicine, Chiba, Japan
| | - Shigeto Naito
- Division of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi, Japan
| |
Collapse
|
100
|
Pook C, Kuhn E, Singh A, Kovach J. Contact force ablation of accessory pathways in pediatric patients. J Cardiovasc Electrophysiol 2020; 32:370-375. [PMID: 33205493 DOI: 10.1111/jce.14817] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 10/30/2020] [Accepted: 11/05/2020] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Contact force (CF) catheters provide feedback confirming adequate tissue contact for optimal lesion size and minimal complications. CF ablation catheters have resulted in decreased procedure times and improved outcomes for ablation of atrial fibrillation in adults. There is limited data evaluating CF use for accessory pathway (AP) ablation or in pediatric patients. The aim of our study was to compare a cohort who underwent AP ablation with a CF catheter to historical controls, evaluating for differences in procedure times, number of lesions, and outcomes. METHODS A retrospective chart review of CF ablation cases at Children's Wisconsin performed between June 2015 to April 2018 was compared to a historical control cohort of traditional radiofrequency (RF) ablations between June 2012 and June 2015. 43 patients with APs underwent 49 CF ablation procedures (18 males, 13.6 ± 3 years old) and a control cohort consisted of 77 procedures in 69 patients (38 males, 12.4 ± 4 years). RESULTS The groups did not differ significantly on procedure time (CF 2.01 ± 0.48 h, control 1.53 ± 0.48 h, p = .37), or total lesions administered (CF and control 7 ± 6 lesions, p = .89). CF cases showed a trend toward improvement in acute success (98% CF, 90% controls, p = .15) though with increased recurrence compared to controls (13% CF, 4.3% controls, p = .16), neither being statistically significant. CONCLUSION Our study suggests that ablation outcomes using CF are comparable to traditional RF ablation in pediatric patients with APs.
Collapse
Affiliation(s)
- Caitlin Pook
- Department of Pediatrics, Medical College of Wisconsin, Wauwatosa, Wisconsin, USA
| | - Evelyn Kuhn
- Department of Business Intelligence and Data Warehousing, Children's Wisconsin, Wauwatosa, Wisconsin, USA
| | - Anoop Singh
- Department of Pediatrics, Medical College of Wisconsin, Wauwatosa, Wisconsin, USA
| | - Joshua Kovach
- Department of Pediatrics, Medical College of Wisconsin, Wauwatosa, Wisconsin, USA
| |
Collapse
|