101
|
Scroccarello A, Della Pelle F, Ferraro G, Fratini E, Tempera F, Dainese E, Compagnone D. Plasmonic active film integrating gold/silver nanostructures for H 2O 2 readout. Talanta 2020; 222:121682. [PMID: 33167288 DOI: 10.1016/j.talanta.2020.121682] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 09/13/2020] [Accepted: 09/15/2020] [Indexed: 12/16/2022]
Abstract
A nanostructured Ag/Au adhesive film for H2O2 reagentless determination is here proposed. The film has been realised onto ELISA polystyrene microplates. Microwells surface has been initially modified with a gold nanoparticles (AuNPs)/polydopamine thin-film. The pristine AuNPs-decorated film was later functionalized with catechin (Au-CT) allowing a uniform formation of a plasmonic active nanostructured silver network in presence of Ag+. Changes in localized surface plasmon resonance (LSPR) of the silver network upon addition of H2O2 has been used as analytical signal, taking advantage of the etching phenomenon. The Ag/Au nanocomposite-film is characterized by a well-defined (LSPRmax = 405 ± 5 nm), reproducible (intraplate RSD ≤ 9.8%, n = 96; inter-plate RSD ≤ 11.4%, n = 480) and stable LSPR signal. The film's analytical features have been tested for H2O2 and glucose (bio)sensing. Satisfactory analytical performances were obtained both for H2O2 (linear range 1-200 μM, R2 = 0.9992, RSD ≤ 6.3%, LOD = 0.2 μM) and glucose (linear range 2-250 μM, R2 = 0.9998, RSD ≤ 8.9%, LOD = 0.4 μM). As proof of applicability, the determination of the two analytes in soft drinks has been carried out achieving good and reproducible recoveries (84-111%; RSD ≤ 9%). The developed nanostructured film overcomes analytical drawbacks associated with the use of colloidal dispersions in plasmonic assays carried out in solution; the low cost, robustness, ease of use and possibility of coupling enzymatic reactions appears very promising for (bio)sensors based on the detection of H2O2.
Collapse
Affiliation(s)
- Annalisa Scroccarello
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Via Renato Balzarini 1, 64100, Teramo, Italy
| | - Flavio Della Pelle
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Via Renato Balzarini 1, 64100, Teramo, Italy.
| | - Giovanni Ferraro
- Department of Chemistry "Ugo Schiff" and CSGI, University of Florence, Via Della Lastruccia 3-Sesto Fiorentino, I-50019, Florence, Italy
| | - Emiliano Fratini
- Department of Chemistry "Ugo Schiff" and CSGI, University of Florence, Via Della Lastruccia 3-Sesto Fiorentino, I-50019, Florence, Italy
| | - Francesco Tempera
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Via Renato Balzarini 1, 64100, Teramo, Italy
| | - Enrico Dainese
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Via Renato Balzarini 1, 64100, Teramo, Italy
| | - Dario Compagnone
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Via Renato Balzarini 1, 64100, Teramo, Italy.
| |
Collapse
|
102
|
Martínez-Periñán E, Gutiérrez-Sánchez C, García-Mendiola T, Lorenzo E. Electrochemiluminescence Biosensors Using Screen-Printed Electrodes. BIOSENSORS-BASEL 2020; 10:bios10090118. [PMID: 32916838 PMCID: PMC7559215 DOI: 10.3390/bios10090118] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 09/03/2020] [Accepted: 09/07/2020] [Indexed: 12/25/2022]
Abstract
Electrogenerated chemiluminescence (also called electrochemiluminescence (ECL)) has become a great focus of attention in different fields of analysis, mainly as a consequence of the potential remarkably high sensitivity and wide dynamic range. In the particular case of sensing applications, ECL biosensor unites the benefits of the high selectivity of biological recognition elements and the high sensitivity of ECL analysis methods. Hence, it is a powerful analytical device for sensitive detection of different analytes of interest in medical prognosis and diagnosis, food control and environment. These wide range of applications are increased by the introduction of screen-printed electrodes (SPEs). Disposable SPE-based biosensors cover the need to perform in-situ measurements with portable devices quickly and accurately. In this review, we sum up the latest biosensing applications and current progress on ECL bioanalysis combined with disposable SPEs in the field of bio affinity ECL sensors including immunosensors, DNA analysis and catalytic ECL sensors. Furthermore, the integration of nanomaterials with particular physical and chemical properties in the ECL biosensing systems has improved tremendously their sensitivity and overall performance, being one of the most appropriates research fields for the development of highly sensitive ECL biosensor devices.
Collapse
Affiliation(s)
- Emiliano Martínez-Periñán
- Departamento de Química Analítica y Análisis Instrumental Universidad Autónoma de Madrid, 28049 Madrid, Spain; (E.M.-P.); (C.G.-S.); (T.G.-M.)
| | - Cristina Gutiérrez-Sánchez
- Departamento de Química Analítica y Análisis Instrumental Universidad Autónoma de Madrid, 28049 Madrid, Spain; (E.M.-P.); (C.G.-S.); (T.G.-M.)
| | - Tania García-Mendiola
- Departamento de Química Analítica y Análisis Instrumental Universidad Autónoma de Madrid, 28049 Madrid, Spain; (E.M.-P.); (C.G.-S.); (T.G.-M.)
- Institute for Advanced Research in Chemical Sciences (IAdChem) Universidad Autónoma de Madrid, 28049 Madrid, Spain
- IMDEA-Nanociencia, Ciudad Universitaria de Cantoblanco, 28049 Madrid, Spain
| | - Encarnación Lorenzo
- Departamento de Química Analítica y Análisis Instrumental Universidad Autónoma de Madrid, 28049 Madrid, Spain; (E.M.-P.); (C.G.-S.); (T.G.-M.)
- Institute for Advanced Research in Chemical Sciences (IAdChem) Universidad Autónoma de Madrid, 28049 Madrid, Spain
- IMDEA-Nanociencia, Ciudad Universitaria de Cantoblanco, 28049 Madrid, Spain
- Correspondence: ; Tel.: +34-91-497-4488
| |
Collapse
|
103
|
Printed Electrodes in Microfluidic Arrays for Cancer Biomarker Protein Detection. BIOSENSORS-BASEL 2020; 10:bios10090115. [PMID: 32906644 PMCID: PMC7559629 DOI: 10.3390/bios10090115] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 08/27/2020] [Accepted: 09/01/2020] [Indexed: 12/27/2022]
Abstract
Medical diagnostics is trending towards a more personalized future approach in which multiple tests can be digitized into patient records. In cancer diagnostics, patients can be tested for individual protein and genomic biomarkers that detect cancers at very early stages and also be used to monitor cancer progression or remission during therapy. These data can then be incorporated into patient records that could be easily accessed on a cell phone by a health care professional or the patients themselves on demand. Data on protein biomarkers have a large potential to be measured in point-of-care devices, particularly diagnostic panels that could provide a continually updated, personalized record of a disease like cancer. Electrochemical immunoassays have been popular among protein detection methods due to their inherent high sensitivity and ease of coupling with screen-printed and inkjet-printed electrodes. Integrated chips featuring these kinds of electrodes can be built at low cost and designed for ease of automation. Enzyme-linked immunosorbent assay (ELISA) features are adopted in most of these ultrasensitive detection systems, with microfluidics allowing easy manipulation and good fluid dynamics to deliver reagents and detect the desired proteins. Several of these ultrasensitive systems have detected biomarker panels ranging from four to eight proteins, which in many cases when a specific cancer is suspected may be sufficient. However, a grand challenge lies in engineering microfluidic-printed electrode devices for the simultaneous detection of larger protein panels (e.g., 50-100) that could be used to test for many types of cancers, as well as other diseases for truly personalized care.
Collapse
|
104
|
Erdem A, Eksin E. Impedimetric Sensing of Factor V Leiden Mutation by Zip Nucleic Acid Probe and Electrochemical Array. BIOSENSORS-BASEL 2020; 10:bios10090116. [PMID: 32906640 PMCID: PMC7559847 DOI: 10.3390/bios10090116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 08/27/2020] [Accepted: 09/03/2020] [Indexed: 12/02/2022]
Abstract
A carbon nanofiber enriched 8-channel screen-printed electrochemical array was used for the impedimetric detection of SNP related to Factor V Leiden (FV Leiden) mutation, which is the most common inherited form of thrombophilia. FV Leiden mutation sensing was carried out in three steps: solution-phase nucleic acid hybridization between zip nucleic acid probe (Z-probe) and mutant type DNA target, followed by the immobilization of the hybrid on the working electrode area of array, and measurement by electrochemical impedance spectroscopy (EIS). The selectivity of the assay was tested against mutation-free DNA sequences and synthetic polymerase chain reaction (PCR) samples. The developed biosensor was a trustful assay for FV Leiden mutation diagnosis, which can effectively discriminate wild type and mutant type even in PCR samples.
Collapse
|
105
|
Hassani S, Rezaei Akmal M, Salek Maghsoudi A, Rahmani S, Vakhshiteh F, Norouzi P, Ganjali MR, Abdollahi M. High-Performance Voltammetric Aptasensing Platform for Ultrasensitive Detection of Bisphenol A as an Environmental Pollutant. Front Bioeng Biotechnol 2020; 8:574846. [PMID: 33015024 PMCID: PMC7498542 DOI: 10.3389/fbioe.2020.574846] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Accepted: 08/17/2020] [Indexed: 12/15/2022] Open
Abstract
Bisphenol A (BPA) as a pervasive endocrine-disrupting compound (EDC) has been shown to cause multiple detrimental effects including cardiovascular disorders, pregnancy complications, obesity, glucose metabolism disorders, and reproductive toxicity even at a concentration as low as tolerable daily intake (TDI) (4 μg/kg/day). In the present study, a novel ultra-sensitive, electrochemical aptasensor was designed using a screen-printed carbon electrode (SPCE) modified by gold nanoparticles (Au NPs) conjugated to thiolated aptamers for accurate determination of BPA in biological, industrial and environmental samples. To characterize the electrochemical properties of the aptasensor, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were implemented. Detection of BPA was also performed through differential pulse voltammetry (DPV) in [Fe(CN)6]3–/4– electrolyte solution. Under optimum condition, the present electrochemical aptasensor demonstrated an outstanding linear response in the concentration range of 1 pM to 10 nM with a remarkably low limit of detection of 0.113 pM. Due to the superb affinity between anti-BPA aptamers and BPA molecules, the designed aptasensor did not show any significant interaction with other analytes in real samples. Also, fabricated biosensor remained perfectly stable in long-term storage. The analytical results of the fabricated aptasensor are well compatible with those obtained by the ELISA method, indicating the trustworthiness and reasonable accuracy of the application of aptasensor in real samples. Overall, the proposed aptasensor would be a credible and economical method of precise, reproducible, and highly selective detection of minimum levels of BPA in food containers and clinical samples. This would be a promising strategy to enhance the safety of food products and reduce the risk of BPA daily exposure.
Collapse
Affiliation(s)
- Shokoufeh Hassani
- Toxicology and Diseases Group (TDG), Pharmaceutical Sciences Research Center (PSRC), The Institute of Pharmaceutical Sciences (TIPS), and Department of Toxicology and Pharmacology, School of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| | - Milad Rezaei Akmal
- Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran
| | - Armin Salek Maghsoudi
- Toxicology and Diseases Group (TDG), Pharmaceutical Sciences Research Center (PSRC), The Institute of Pharmaceutical Sciences (TIPS), and Department of Toxicology and Pharmacology, School of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| | - Soheila Rahmani
- Toxicology and Diseases Group (TDG), Pharmaceutical Sciences Research Center (PSRC), The Institute of Pharmaceutical Sciences (TIPS), and Department of Toxicology and Pharmacology, School of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| | - Faezeh Vakhshiteh
- Nanotechnology Research Centre, School of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| | - Parviz Norouzi
- Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran.,Endocrinology and Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran
| | - Mohammad Reza Ganjali
- Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran.,Endocrinology and Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran
| | - Mohammad Abdollahi
- Toxicology and Diseases Group (TDG), Pharmaceutical Sciences Research Center (PSRC), The Institute of Pharmaceutical Sciences (TIPS), and Department of Toxicology and Pharmacology, School of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran.,Endocrinology and Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
106
|
Cumba LR, Camisasca A, Giordani S, Forster RJ. Electrochemical Properties of Screen-Printed Carbon Nano-Onion Electrodes. Molecules 2020; 25:molecules25173884. [PMID: 32858929 PMCID: PMC7503887 DOI: 10.3390/molecules25173884] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 08/21/2020] [Accepted: 08/24/2020] [Indexed: 12/11/2022] Open
Abstract
The properties of carbon nano-onions (CNOs) make them attractive electrode materials/additives for the development of low-cost, simple to use and highly sensitive Screen Printed Electrodes (SPEs). Here, we report the development of the first CNO-based ink for the fabrication of low-cost and disposable electrodes, leading to high-performance sensors. Achieving a true dispersion of CNOs is intrinsically challenging and a key aspect of the ink formulation. The screen-printing ink formulation is achieved by carefully selecting and optimising the conductive materials (graphite (GRT) and CNOs), the polymer binder, the organic solvent and the plasticiser. Our CNO/GRT-based screen-printed electrodes consist of an interconnected network of conducting carbon particles with a uniform distribution. Electrochemical studies show a heterogeneous electron transfer rate constant of 1.3 ± 0.7 × 10-3 cm·s-1 and a higher current density than the ferrocene/ferrocenium coupled to a commercial graphite SPEs. In addition, the CNO/GRT SPE can detect dopamine in the concentration range of 10.0-99.9 µM with a limit of detection of 0.92 µM (N = 3). They exhibit a higher analytical sensitivity than the commercial graphite-based SPE, with a 4-fold improvement observed. These results open up the possibility of using high-performing CNO-based SPEs for electrochemical applications including sensors, battery electrodes and electrocatalysis.
Collapse
Affiliation(s)
- Loanda R. Cumba
- School of Chemical Sciences, National Centre for Sensor Research, Dublin City University, Dublin 9, Ireland; (A.C.); (R.J.F.)
- Correspondence: (L.R.C.); (S.G.)
| | - Adalberto Camisasca
- School of Chemical Sciences, National Centre for Sensor Research, Dublin City University, Dublin 9, Ireland; (A.C.); (R.J.F.)
| | - Silvia Giordani
- School of Chemical Sciences, National Centre for Sensor Research, Dublin City University, Dublin 9, Ireland; (A.C.); (R.J.F.)
- Correspondence: (L.R.C.); (S.G.)
| | - Robert J. Forster
- School of Chemical Sciences, National Centre for Sensor Research, Dublin City University, Dublin 9, Ireland; (A.C.); (R.J.F.)
- FutureNeuro SFI Research Centre, Dublin, Ireland
| |
Collapse
|
107
|
Wang JS, Sakthivel R, Anbazhagan R, Krishnamoorthi R, Kubendhiran S, Lai JY, Tsai HC, Chen SM. Electroactive polypyrrole-molybdenum disulfide nanocomposite for ultrasensitive detection of berberine in rat plasma. Anal Chim Acta 2020; 1125:210-219. [PMID: 32674768 DOI: 10.1016/j.aca.2020.05.056] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Revised: 04/28/2020] [Accepted: 05/21/2020] [Indexed: 12/31/2022]
Abstract
Electroactive polypyrrole-molybdenum disulfide (MoP) nanocomposites were synthesized and used for modifying screen-printed carbon electrodes (SPCEs) for ultrasensitive detection of berberine, an anticancer drug, in rat plasma. The electroactive nanocomposites were fabricated by exfoliating MoS2 followed by pyrrole polymerization. The effect of polypyrrole in the MoP nanocomposite was evaluated by varying the pyrrole concentration during polymerization, and the resulting nanocomposites prepared with pyrrole concentrations of 10, 20, 30 μL were named as MoP-1, MoP-2, and MoP-3, respectively. The electrochemical characterization of the three MoP nanocomposite sensors revealed that MoP-2/SPCE exhibited the highest electroactivity. The detection of berberine by the three MoP-coated SPCEs revealed that MoP-2/SPCE exhibited the highest activity against berberine due to a two-electron transfer mechanism on the MoP-2/SPCE electrode surface. The detection limit of berberine using the MoP-2/SPCE sensor was found to be about 0.05 μM, which is remarkably lower than the reported detection limits. The interference study proved the selectivity of the MoP-2/SPCE sensor toward berberine in the presence of other bioactive molecules and metal ions. The designed MoP-2/SPCE sensor retained 92% of its initial activity after 15 days of storage at room temperature, with RSD values of about 2.95% and 3.68% for the repeatability and reproducibility studies. Finally, the detection limit of berberine in a rat plasma sample determined using the MoP-2/SPCE sensor was found to be about 5 μM.
Collapse
Affiliation(s)
- Jun-Sheng Wang
- Taiwan Instrument Research Institute, National Applied Research Laboratories, Hsinchu, Taiwan
| | - Rajalakshmi Sakthivel
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei, Taiwan
| | - Rajeshkumar Anbazhagan
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, Taiwan; Advanced Membrane Materials Research Center, Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, Taiwan.
| | - Rajakumari Krishnamoorthi
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, Taiwan; Advanced Membrane Materials Research Center, Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, Taiwan
| | | | - Juin-Yih Lai
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, Taiwan; Advanced Membrane Materials Research Center, Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, Taiwan; R&D Center for Membrane Technology, Chung Yuan Christian University, Taiwan
| | - Hsieh-Chih Tsai
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, Taiwan; Advanced Membrane Materials Research Center, Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, Taiwan; R&D Center for Membrane Technology, Chung Yuan Christian University, Taiwan.
| | - Shen-Ming Chen
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei, Taiwan.
| |
Collapse
|
108
|
An electrochemical biosensor based on multi-wall carbon nanotube-modified screen-printed electrode immobilized by uricase for the detection of salivary uric acid. Anal Bioanal Chem 2020; 412:7275-7283. [PMID: 32794003 DOI: 10.1007/s00216-020-02860-w] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 07/28/2020] [Accepted: 08/03/2020] [Indexed: 12/13/2022]
Abstract
The amounts of uric acid (UA) in non-invasive biological samples, such as saliva, are critical for diagnosis and therapy of gout, hyperuricemia, Lesch-Nyhan syndrome, and several other diseases. Here, disposable UA biosensors were fabricated with the screen printing technique on the substrate of flexible PET. The working electrode was modified with carbon nanotubes followed by uricase for UA detection with excellent selectivity. The biosensor showed good electrocatalytic activity toward UA with high sensitivity, low detection limit, and wide linear range, which covers the full range of UA levels in human saliva. We demonstrate that UA can be directly detected in human saliva with the biosensor and the experimental data were consistent with the clinical analysis. This study indicated that the non-invasive biosensor is an attractive and possible approach for the monitoring of salivary UA. Graphical abstract A disposable uric acid biosensor modified with carbon nanotubes followed by uricase was fabricated on flexible PET and applied for the monitoring of salivary uric acid in human saliva.
Collapse
|
109
|
Hartati YW, Gaffar S, Alfiani D, Pratomo U, Sofiatin Y, Subroto T. A voltammetric immunosensor based on gold nanoparticle - Anti-ENaC bioconjugate for the detection of epithelial sodium channel (ENaC) protein as a biomarker of hypertension. SENSING AND BIO-SENSING RESEARCH 2020. [DOI: 10.1016/j.sbsr.2020.100343] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
|
110
|
Gajdosova V, Lorencova L, Kasak P, Tkac J. Electrochemical Nanobiosensors for Detection of Breast Cancer Biomarkers. SENSORS (BASEL, SWITZERLAND) 2020; 20:E4022. [PMID: 32698389 PMCID: PMC7412172 DOI: 10.3390/s20144022] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 07/14/2020] [Accepted: 07/15/2020] [Indexed: 12/16/2022]
Abstract
This comprehensive review paper describes recent advances made in the field of electrochemical nanobiosensors for the detection of breast cancer (BC) biomarkers such as specific genes, microRNA, proteins, circulating tumor cells, BC cell lines, and exosomes or exosome-derived biomarkers. Besides the description of key functional characteristics of electrochemical nanobiosensors, the reader can find basic statistic information about BC incidence and mortality, breast pathology, and current clinically used BC biomarkers. The final part of the review is focused on challenges that need to be addressed in order to apply electrochemical nanobiosensors in a clinical practice.
Collapse
Affiliation(s)
- Veronika Gajdosova
- Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, 845 38 Bratislava, Slovakia; (V.G.); (L.L.)
| | - Lenka Lorencova
- Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, 845 38 Bratislava, Slovakia; (V.G.); (L.L.)
| | - Peter Kasak
- Center for Advanced Materials, Qatar University, Doha 2713, Qatar
| | - Jan Tkac
- Institute of Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, 845 38 Bratislava, Slovakia; (V.G.); (L.L.)
| |
Collapse
|
111
|
Sigolaeva LV, Bulko TV, Konyakhina AY, Kuzikov AV, Masamrekh RA, Max JB, Köhler M, Schacher FH, Pergushov DV, Shumyantseva VV. Rational Design of Amphiphilic Diblock Copolymer/MWCNT Surface Modifiers and Their Application for Direct Electrochemical Sensing of DNA. Polymers (Basel) 2020; 12:polym12071514. [PMID: 32650434 PMCID: PMC7407114 DOI: 10.3390/polym12071514] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 06/23/2020] [Accepted: 07/03/2020] [Indexed: 02/07/2023] Open
Abstract
We demonstrate the application of amphiphilic ionic poly(n-butylmethacrylate)-block- poly(2-(dimethylamino)ethyl methacrylate) diblock copolymers (PnBMA40-b-PDMAEMA40, PnBMA40-b-PDMAEMA120, PnBMA70-b-PDMAEMA120) for dispersing multiwalled carbon nanotubes (MWCNTs) in aqueous media, a subsequent efficient surface modification of screen-printed electrodes (SPEs), and the application of the modified SPEs for DNA electrochemistry. Stable and fine aqueous dispersions of MWCNTs were obtained with PnBMAx-b-PDMAEMAy diblock copolymers, regardless of the structure of the copolymer and the amount of MWCNTs in the dispersions. The effect of the diblock copolymer structure was important when the dispersions of MWCNTs were deposited as modifying layers on surfaces of SPEs, resulting in considerable increases of the electroactive surface areas and great acceleration of the electron transfer rate. The SPE/(PnBMAx-b-PDMAEMAy + MWCNT) constructs were further exploited for direct electrochemical oxidation of the guanine (G) and adenine (A) residues in a model salmon sperm double-stranded DNA (dsDNA). Two well-defined irreversible oxidation peaks were observed at about +600 and +900 mV, corresponding to the electrochemical oxidation of G and A residues, respectively. A multi-parametric optimization of dsDNA electrochemistry enables one to get the limits of detection (LOD) as low as 5 μg/mL (0.25 μM) and 1 μg/mL (0.05 μM) for G and A residues, respectively. The achieved sensitivity of DNA assay enables quantification of the A and G residues of dsDNA in the presence of human serum and DNA in isolated human leukocytes.
Collapse
Affiliation(s)
- Larisa V. Sigolaeva
- Department of Chemistry, M.V. Lomonosov Moscow State University, Leninskie Gory 1/3, 119991 Moscow, Russia; (T.V.B.); (A.Y.K.); (A.V.K.); (R.A.M.); (D.V.P.); (V.V.S.)
- V.N. Orekhovich Institute of Biomedical Chemistry, 119121 Moscow, Russia
- Correspondence: ; Tel.: +7-495-939-40-42
| | - Tatiana V. Bulko
- Department of Chemistry, M.V. Lomonosov Moscow State University, Leninskie Gory 1/3, 119991 Moscow, Russia; (T.V.B.); (A.Y.K.); (A.V.K.); (R.A.M.); (D.V.P.); (V.V.S.)
- V.N. Orekhovich Institute of Biomedical Chemistry, 119121 Moscow, Russia
| | - Apollinariya Yu. Konyakhina
- Department of Chemistry, M.V. Lomonosov Moscow State University, Leninskie Gory 1/3, 119991 Moscow, Russia; (T.V.B.); (A.Y.K.); (A.V.K.); (R.A.M.); (D.V.P.); (V.V.S.)
| | - Alexey V. Kuzikov
- Department of Chemistry, M.V. Lomonosov Moscow State University, Leninskie Gory 1/3, 119991 Moscow, Russia; (T.V.B.); (A.Y.K.); (A.V.K.); (R.A.M.); (D.V.P.); (V.V.S.)
- V.N. Orekhovich Institute of Biomedical Chemistry, 119121 Moscow, Russia
- Pirogov Russian National Research Medical University, 117997 Moscow, Russia
| | - Rami A. Masamrekh
- Department of Chemistry, M.V. Lomonosov Moscow State University, Leninskie Gory 1/3, 119991 Moscow, Russia; (T.V.B.); (A.Y.K.); (A.V.K.); (R.A.M.); (D.V.P.); (V.V.S.)
- V.N. Orekhovich Institute of Biomedical Chemistry, 119121 Moscow, Russia
- Pirogov Russian National Research Medical University, 117997 Moscow, Russia
| | - Johannes B. Max
- Institute of Organic Chemistry and Macromolecular Chemistry (IOMC), Friedrich-Schiller-University Jena, D-07743 Jena, Germany; (J.B.M.); (M.K.); (F.H.S.)
| | - Moritz Köhler
- Institute of Organic Chemistry and Macromolecular Chemistry (IOMC), Friedrich-Schiller-University Jena, D-07743 Jena, Germany; (J.B.M.); (M.K.); (F.H.S.)
| | - Felix H. Schacher
- Institute of Organic Chemistry and Macromolecular Chemistry (IOMC), Friedrich-Schiller-University Jena, D-07743 Jena, Germany; (J.B.M.); (M.K.); (F.H.S.)
- Jena Center for Soft Matter (JCSM), Friedrich-Schiller-University Jena, D-07743 Jena, Germany
- Center for Energy and Environmental Chemistry (CEEC), Friedrich-Schiller-University Jena, D-07743 Jena, Germany
| | - Dmitry V. Pergushov
- Department of Chemistry, M.V. Lomonosov Moscow State University, Leninskie Gory 1/3, 119991 Moscow, Russia; (T.V.B.); (A.Y.K.); (A.V.K.); (R.A.M.); (D.V.P.); (V.V.S.)
| | - Victoria V. Shumyantseva
- Department of Chemistry, M.V. Lomonosov Moscow State University, Leninskie Gory 1/3, 119991 Moscow, Russia; (T.V.B.); (A.Y.K.); (A.V.K.); (R.A.M.); (D.V.P.); (V.V.S.)
- V.N. Orekhovich Institute of Biomedical Chemistry, 119121 Moscow, Russia
- Pirogov Russian National Research Medical University, 117997 Moscow, Russia
| |
Collapse
|
112
|
Cagnani GR, Ibáñez-Redín G, Tirich B, Gonçalves D, Balogh DT, Oliveira ON. Fully-printed electrochemical sensors made with flexible screen-printed electrodes modified by roll-to-roll slot-die coating. Biosens Bioelectron 2020; 165:112428. [PMID: 32729544 DOI: 10.1016/j.bios.2020.112428] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 06/12/2020] [Accepted: 07/03/2020] [Indexed: 01/28/2023]
Abstract
The manufacture of sensors using large-scale production techniques, such as roll-to-roll (R2R) processing, may fulfill requirements of low-cost disposable devices. Herein, we report the fabrication of fully-printed electrochemical sensors using screen-printed carbon electrodes coated with carbon black inks through slot-die coating within an R2R process. As a proof of concept, sensors were produced to detect the neurotransmitter dopamine with high reproducibility and low limit of detection (0.09 μmol L-1). Furthermore, fully-printed biosensors made with a tyrosinase-containing ink were used to detect catechol in natural water samples. Since slot-die deposition enables printing enzymes without significant activity loss, the biosensors exhibited high stability over a period of several weeks. Even more important, R2R slot-die coating may be extended to any type of sensors and biosensors with the possibility of large-scale manufacturing.
Collapse
Affiliation(s)
- Giovana Rosso Cagnani
- Sao Carlos Institute of Physics, University of Sao Paulo, 13560-970, São Carlos, São Paulo, Brazil.
| | - Gisela Ibáñez-Redín
- Sao Carlos Institute of Physics, University of Sao Paulo, 13560-970, São Carlos, São Paulo, Brazil
| | - Beatriz Tirich
- Sao Carlos Institute of Physics, University of Sao Paulo, 13560-970, São Carlos, São Paulo, Brazil
| | - Débora Gonçalves
- Sao Carlos Institute of Physics, University of Sao Paulo, 13560-970, São Carlos, São Paulo, Brazil
| | - Debora T Balogh
- Sao Carlos Institute of Physics, University of Sao Paulo, 13560-970, São Carlos, São Paulo, Brazil
| | - Osvaldo N Oliveira
- Sao Carlos Institute of Physics, University of Sao Paulo, 13560-970, São Carlos, São Paulo, Brazil
| |
Collapse
|
113
|
Ibáñez-Redín G, Materon EM, Furuta RHM, Wilson D, do Nascimento GF, Melendez ME, Carvalho AL, Reis RM, Oliveira ON, Gonçalves D. Screen-printed electrodes modified with carbon black and polyelectrolyte films for determination of cancer marker carbohydrate antigen 19-9. Mikrochim Acta 2020; 187:417. [DOI: 10.1007/s00604-020-04404-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Accepted: 06/17/2020] [Indexed: 11/24/2022]
|
114
|
Fakude CT, Arotiba OA, Arduini F, Mabuba N. Flexible Polyester Screen‐printed Electrode Modified with Carbon Nanofibers for the Electrochemical Aptasensing of Cadmium (II). ELECTROANAL 2020. [DOI: 10.1002/elan.202060070] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Affiliation(s)
- Colani T Fakude
- Department of Chemical Sciences University of Johannesburg Doornfontein 2028 Johannesburg South Africa
| | - Omotayo A Arotiba
- Department of Chemical Sciences University of Johannesburg Doornfontein 2028 Johannesburg South Africa
- Centre for Nanomaterials Science Research University of Johannesburg 2028 Johannesburg South Africa
| | - Fabiana Arduini
- Department of Chemical Science and Technologies University of Rome “Tor Vergata” 00133 Rome Italy
| | - Nonhlangabezo Mabuba
- Department of Chemical Sciences University of Johannesburg Doornfontein 2028 Johannesburg South Africa
- Centre for Nanomaterials Science Research University of Johannesburg 2028 Johannesburg South Africa
| |
Collapse
|
115
|
Díaz-Cruz JM, Serrano N, Pérez-Ràfols C, Ariño C, Esteban M. Electroanalysis from the past to the twenty-first century: challenges and perspectives. J Solid State Electrochem 2020; 24:2653-2661. [PMID: 32837295 PMCID: PMC7306008 DOI: 10.1007/s10008-020-04733-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 06/15/2020] [Accepted: 06/16/2020] [Indexed: 12/14/2022]
Abstract
A personal mini-review is presented on the history of electroanalysis and on their present achievements and future challenges. The manuscript is written from the subjective view of two generations of electroanalytical chemists that have witnessed for many years the evolution of this discipline.
Collapse
Affiliation(s)
- José Manuel Díaz-Cruz
- Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Martí i Franquès 1-11, E08028 Barcelona, Spain
- Water Research Institute (IdRA) of the University of Barcelona, Barcelona, Spain
| | - Núria Serrano
- Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Martí i Franquès 1-11, E08028 Barcelona, Spain
- Water Research Institute (IdRA) of the University of Barcelona, Barcelona, Spain
| | - Clara Pérez-Ràfols
- Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Martí i Franquès 1-11, E08028 Barcelona, Spain
- Department of Chemistry, School of Engineering Science in Chemistry, Biochemistry and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-10044 Stockholm, Sweden
| | - Cristina Ariño
- Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Martí i Franquès 1-11, E08028 Barcelona, Spain
- Water Research Institute (IdRA) of the University of Barcelona, Barcelona, Spain
| | - Miquel Esteban
- Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Martí i Franquès 1-11, E08028 Barcelona, Spain
- Water Research Institute (IdRA) of the University of Barcelona, Barcelona, Spain
| |
Collapse
|
116
|
de Castro ACH, Alves LM, Siquieroli ACS, Madurro JM, Brito-Madurro AG. Label-free electrochemical immunosensor for detection of oncomarker CA125 in serum. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104746] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
117
|
Kang PL, Lin YH, Settu K, Yen CS, Yeh CY, Liu JT, Chen CJ, Chang SJ. A Facile Fabrication of Biodegradable and Biocompatible Cross-Linked Gelatin as Screen Printing Substrates. Polymers (Basel) 2020; 12:polym12051186. [PMID: 32456005 PMCID: PMC7284702 DOI: 10.3390/polym12051186] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 05/15/2020] [Accepted: 05/19/2020] [Indexed: 01/06/2023] Open
Abstract
This study focuses on preparation and valuation of the biodegradable, native, and modified gelatin film as screen-printing substrates. Modified gelatin film was prepared by crosslinking with various crosslinking agents and the electrode array was designed by screen-printing. It was observed that the swelling ratio of C-2, crosslinked with glutaraldehyde and EDC/NHS (1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide) was found to be lower (3.98%) than that of C-1 (crosslinked with only glutaraldehyde) (8.77%) and C-0 (without crosslinking) (28.15%). The obtained results indicate that the swelling ratios of both C-1 and C-2 were found to be lower than that of C-0 (control one without crosslinking). The Young's modulus for C-1 and C-2 was found to be 8.55 ± 0.57 and 23.72 ± 2.04 kPa, respectively. Hence, it was conveyed that the mechanical strength of C-2 was found to be two times higher than that of C-l, suggesting that the mechanical strength was enhanced upon dual crosslinking in this study also. The adhesion study indicates that silver ink adhesion on the gelation surface is better than that of carbon ink. In addition, the electrical response of C-2 with a screen-printed electrode (SPE) was found to be the same as the commercial polycarbonate (PC) substrate. The result of MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide) assay suggested that the silver SPE on C-2 was non-cytotoxic toward L929 fibroblast cells proliferation. The results indicated that C-2 gelatin is a promising material to act as a screen-printing substrate with excellent biodegradable and biocompatible properties.
Collapse
Affiliation(s)
- Pei-Leun Kang
- Cardiovascular Surgery, Department of Surgery, Kaohsiung Veterans General Hospital, Kaohsiung 81362, Taiwan; (P.-L.K.); (Y.-H.L.)
| | - Yu-Hsin Lin
- Cardiovascular Surgery, Department of Surgery, Kaohsiung Veterans General Hospital, Kaohsiung 81362, Taiwan; (P.-L.K.); (Y.-H.L.)
| | - Kalpana Settu
- Department of Electrical Engineering, National Taipei University, New Taipei 23741, Taiwan;
| | - Ching-Shu Yen
- Department of Biomedical Engineering, I-Shou University, Kaohsiung 82445, Taiwan; (C.-S.Y.); (C.-Y.Y.)
| | - Chin-Yi Yeh
- Department of Biomedical Engineering, I-Shou University, Kaohsiung 82445, Taiwan; (C.-S.Y.); (C.-Y.Y.)
| | - Jen-Tsai Liu
- College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing 100049, China
- Correspondence: (J.-T.L.); (C.-J.C.); (S.-J.C.); Tel.: +886-76151100-7467 (S.-J.C.)
| | - Ching-Jung Chen
- School of Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing 100049, China
- Correspondence: (J.-T.L.); (C.-J.C.); (S.-J.C.); Tel.: +886-76151100-7467 (S.-J.C.)
| | - Shwu-Jen Chang
- Department of Biomedical Engineering, I-Shou University, Kaohsiung 82445, Taiwan; (C.-S.Y.); (C.-Y.Y.)
- Correspondence: (J.-T.L.); (C.-J.C.); (S.-J.C.); Tel.: +886-76151100-7467 (S.-J.C.)
| |
Collapse
|
118
|
Abdel-Moety EM, Abou Al-Alamein AM, Fawaz E, Abd El-Rahman MK. A Companion Diagnostic for Personalizing Mivacurium at the Point-of-Care. JOURNAL OF THE ELECTROCHEMICAL SOCIETY 2020; 167:087510. [DOI: 10.1149/1945-7111/ab927e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
119
|
Khanmohammadi A, Jalili Ghazizadeh A, Hashemi P, Afkhami A, Arduini F, Bagheri H. An overview to electrochemical biosensors and sensors for the detection of environmental contaminants. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2020. [DOI: 10.1007/s13738-020-01940-z] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
120
|
Squissato AL, Munoz RAA, Banks CE, Richter EM. An Overview of Recent Electroanalytical Applications Utilizing Screen‐Printed Electrodes Within Flow Systems. ChemElectroChem 2020. [DOI: 10.1002/celc.202000175] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- André L. Squissato
- Institute of Chemistry Federal University of Uberlandia Av. João Naves de Ávila 2121 – Uberlandia, Minas Gerais Brazil
| | - Rodrigo A. A. Munoz
- Institute of Chemistry Federal University of Uberlandia Av. João Naves de Ávila 2121 – Uberlandia, Minas Gerais Brazil
| | - Craig E. Banks
- Faculty of Science and Engineering Manchester Metropolitan University Chester Street Manchester M1 5GD UK
| | - Eduardo M. Richter
- Institute of Chemistry Federal University of Uberlandia Av. João Naves de Ávila 2121 – Uberlandia, Minas Gerais Brazil
- Faculty of Science and Engineering Manchester Metropolitan University Chester Street Manchester M1 5GD UK
| |
Collapse
|
121
|
Pérez-Fernández B, Costa-García A, Muñiz ADLE. Electrochemical (Bio)Sensors for Pesticides Detection Using Screen-Printed Electrodes. BIOSENSORS 2020; 10:E32. [PMID: 32252430 PMCID: PMC7236603 DOI: 10.3390/bios10040032] [Citation(s) in RCA: 57] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 03/27/2020] [Accepted: 03/30/2020] [Indexed: 12/12/2022]
Abstract
Pesticides are among the most important contaminants in food, leading to important global health problems. While conventional techniques such as high-performance liquid chromatography (HPLC) and mass spectrometry (MS) have traditionally been utilized for the detection of such food contaminants, they are relatively expensive, time-consuming and labor intensive, limiting their use for point-of-care (POC) applications. Electrochemical (bio)sensors are emerging devices meeting such expectations, since they represent reliable, simple, cheap, portable, selective and easy to use analytical tools that can be used outside the laboratories by non-specialized personnel. Screen-printed electrodes (SPEs) stand out from the variety of transducers used in electrochemical (bio)sensing because of their small size, high integration, low cost and ability to measure in few microliters of sample. In this context, in this review article, we summarize and discuss about the use of SPEs as analytical tools in the development of (bio)sensors for pesticides of interest for food control. Finally, aspects related to the analytical performance of the developed (bio)sensors together with prospects for future improvements are discussed.
Collapse
Affiliation(s)
| | | | - Alfredo de la Escosura- Muñiz
- NanoBioAnalysis Group-Department of Physical and Analytical Chemistry, University of Oviedo, Julián Clavería 8, 33006 Oviedo, Spain
| |
Collapse
|
122
|
Tayyab Raza Naqvi S, Rasheed T, Naeem Ashiq M, Najam ul Haq M, Majeed S, Fatima B, Nawaz R, Hussain D, Shafi S. Fabrication of iron modified screen printed carbon electrode for sensing of amino acids. Polyhedron 2020. [DOI: 10.1016/j.poly.2020.114426] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
123
|
Kuzikov AV, Bulko TV, Koroleva PI, Masamrekh RA, Babkina SS, Gilep AA, Shumyantseva VV. [Electroanalytical and electrocatalytical characteristics of cytochrome P450 3A4 using electrodes modified with nanocomposite carbon nanomaterials]. BIOMEDIT︠S︡INSKAI︠A︡ KHIMII︠A︡ 2020; 66:64-70. [PMID: 32116227 DOI: 10.18097/pbmc20206601064] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The electroanalytical characteristics of recombinant cytochrome P450 3A4 (P450 3A4) immobilized on the surface of screen-printed graphite electrodes modified with multi-walled carbon nanotubes have been studied. The role and the influence of graphite working electrode modification with carbon nanotubes on electroanalytical characteristics of cytochrome P450 3A4 have been demonstrated. The conditions for the immobilization of cytochrome P450 3A4 on the obtained screen-printed graphite electrodes modified with carbon multi-walled nanotubes have been optimized. The electrochemical parameters of the oxidation and reduction of the heme iron of the enzyme have been estimated. The midpoint potential E0' was -0.35±0.01 V vs Ag/AgCl; the calculated heterogeneous electron transfer rate constant ks, was 0.57±0.04 s-1; the amount of electroactive cytochrome P450 3A4 on the electrode Г0, was determined as (2.6±0.6)⋅10-10 mol/cm2. The functioning mechanism of P450 3A4-based electrochemical sensor followed the "protein film voltammetry". In order to develop electrochemical analysis of drugs being substrates of that hemoprotein and respective medical biosensors the voltammetric study of catalytic activity of immobilized cytochrome P450 3A4 was carried out. Electrocatalytic properties of cytochrome P450 3A4, immobilized on modified screen-printed graphite electrodes, has been investigated using erythromycin (macrolide antibiotics). It has been shown that the modification of electrodes plays a decisive role for the study of the properties of cytochromes P450 in electrochemical investigations. Smart electrodes can serve as sensors for analytical purposes, as well as electrocatalysts for the study of biotransformation processes and metabolic processes. Electrodes modified with carbon nanomaterials are applicable for analytical purposes in the registration of hemoproteins. Electrodes modified with synthetic membrane-like compounds (e.g. didodecyldimethylammonium bromide) are effective in enzyme-dependent electrocatalysis.
Collapse
Affiliation(s)
- A V Kuzikov
- Institute of Biomedical Chemistry, Moscow, Russia; Pirogov Russian National Research Medical University, Moscow, Russia
| | - T V Bulko
- Institute of Biomedical Chemistry, Moscow, Russia
| | - P I Koroleva
- Institute of Biomedical Chemistry, Moscow, Russia
| | - R A Masamrekh
- Institute of Biomedical Chemistry, Moscow, Russia; Pirogov Russian National Research Medical University, Moscow, Russia
| | - S S Babkina
- Russian Technological University, Moscow, Russia
| | - A A Gilep
- Institute of Bioorganic Chemistry, Minsk, Belarus
| | - V V Shumyantseva
- Institute of Biomedical Chemistry, Moscow, Russia; Pirogov Russian National Research Medical University, Moscow, Russia
| |
Collapse
|
124
|
All-electrochemical nanocomposite two-electrode setup for quantification of drugs and study of their electrocatalytical conversion by cytochromes P450. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2019.135579] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
125
|
Li X, Zhang M, Hu Y, Xu J, Sun D, Hu T, Ni Z. Screen-printed electrochemical biosensor based on a ternary Co@MoS 2/rGO functionalized electrode for high-performance non-enzymatic glucose sensing. Biomed Microdevices 2020; 22:17. [PMID: 32076841 DOI: 10.1007/s10544-020-0472-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
In this study, cobalt oxides functionalized MoS2/reduced graphene oxide was synthesized via a facile one-pot hydrothermal approach. Morphology and crystal structure of this ternary nanoarchitecture were characterized through scanning electron microscopy, transmission electron microscopy, Raman spectra and X-ray photoelectron spectroscopy. An ultrasensitive non-enzymatic glucose sensor was developed by decorating this ternary nanohybrid on the working electrode of a screen-printed electrochemical sensor. Cycle sweep voltammetry and amperometry were used to study the electro-catalytic activity of the modified working electrode, which demonstrated superior catalytic activity towards glucose oxidation with an extremely low detection limit of 30 nM. Meanwhile, this sensor showed an excellent selectivity in the presence of interfering species such as uric acid, ascorbic acid, etc. Based on the screen-printed technique, enzyme mimic nanomaterials could be easily introduced into portable devices, which opens the way to take non-enzymatic glucose electrochemical sensing towards point-of-care.
Collapse
Affiliation(s)
- Xiao Li
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Man Zhang
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Yujie Hu
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Jian Xu
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Dongke Sun
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China
| | - Tao Hu
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| | - Zhonghua Ni
- School of Mechanical Engineering, and Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University, Nanjing, 211189, China.
| |
Collapse
|
126
|
Chou JC, Lin SH, Lai TY, Kuo PY, Lai CH, Nien YH, Su TY. A Facile Fabrication of a Potentiometric Arrayed Glucose Biosensor Based on Nafion-GOx/GO/AZO. SENSORS 2020; 20:s20040964. [PMID: 32054014 PMCID: PMC7071120 DOI: 10.3390/s20040964] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 01/31/2020] [Accepted: 02/07/2020] [Indexed: 12/14/2022]
Abstract
In this study, the potentiometric arrayed glucose biosensors, which were based on zinc oxide (ZnO) or aluminum-doped zinc oxide (AZO) sensing membranes, were fabricated by using screen-printing technology and a sputtering system, and graphene oxide (GO) and Nafion-glucose oxidase (GOx) were used to modify sensing membranes by using the drop-coating method. Next, the material properties were characterized by using a Raman spectrometer, a field-emission scanning electron microscope (FE-SEM), and a scanning probe microscope (SPM). The sensing characteristics of the glucose biosensors were measured by using the voltage–time (V-T) measurement system. Finally, electrochemical impedance spectroscopy (EIS) was conducted to analyze their charge transfer abilities. The results indicated that the average sensitivity of the glucose biosensor based on Nafion-GOx/GO/AZO was apparently higher than that of the glucose biosensor based on Nafion-GOx/GO/ZnO. In addition, the glucose biosensor based on Nafion-GOx/GO/AZO exhibited an excellent average sensitivity of 15.44 mV/mM and linearity of 0.997 over a narrow range of glucose concentration range, a response time of 26 s, a limit of detection (LOD) of 1.89 mM, and good reproducibility. In terms of the reversibility and stability, the hysteresis voltages (VH) were 3.96 mV and 2.42 mV. Additionally, the glucose biosensor also showed good anti-inference ability and reproducibility. According to these results, it is demonstrated that AZO is a promising material, which could be used to develop a reliable, simple, and low-cost potentiometric glucose biosensor.
Collapse
Affiliation(s)
- Jung-Chuan Chou
- Graduate School of Electronic Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan; (S.-H.L.); (T.-Y.L.); (P.-Y.K.); (C.-H.L.)
- Correspondence: ; Tel.: +886-5-534-2601 (ext. #4383)
| | - Si-Hong Lin
- Graduate School of Electronic Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan; (S.-H.L.); (T.-Y.L.); (P.-Y.K.); (C.-H.L.)
| | - Tsu-Yang Lai
- Graduate School of Electronic Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan; (S.-H.L.); (T.-Y.L.); (P.-Y.K.); (C.-H.L.)
| | - Po-Yu Kuo
- Graduate School of Electronic Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan; (S.-H.L.); (T.-Y.L.); (P.-Y.K.); (C.-H.L.)
| | - Chih-Hsien Lai
- Graduate School of Electronic Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan; (S.-H.L.); (T.-Y.L.); (P.-Y.K.); (C.-H.L.)
| | - Yu-Hsun Nien
- Graduate School of Chemical and Materials Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan; (Y.-H.N.); (T.-Y.S.)
| | - Tzu-Yu Su
- Graduate School of Chemical and Materials Engineering, National Yunlin University of Science and Technology, Douliu 64002, Taiwan; (Y.-H.N.); (T.-Y.S.)
| |
Collapse
|
127
|
Valverde A, Serafín V, Montero‐Calle A, González‐Cortés A, Barderas R, Yáñez‐Sedeño P, Campuzano S, Pingarrón JM. Carbon/Inorganic Hybrid Nanoarchitectures as Carriers for Signaling Elements in Electrochemical Immunosensors: First Biosensor for the Determination of the Inflammatory and Metastatic Processes Biomarker RANK‐ligand. ChemElectroChem 2020. [DOI: 10.1002/celc.201902025] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Alejandro Valverde
- Analytical Chemistry Dept., Faculty of ChemistryComplutense University of Madrid. 28040 Madrid Spain
| | - Verónica Serafín
- Analytical Chemistry Dept., Faculty of ChemistryComplutense University of Madrid. 28040 Madrid Spain
| | - Ana Montero‐Calle
- Chronic Disease ProgrammeUFIEC, Instituto de Salud Carlos III 28220 Majadahonda, Madrid Spain
| | - Araceli González‐Cortés
- Analytical Chemistry Dept., Faculty of ChemistryComplutense University of Madrid. 28040 Madrid Spain
| | - Rodrigo Barderas
- Chronic Disease ProgrammeUFIEC, Instituto de Salud Carlos III 28220 Majadahonda, Madrid Spain
| | - Paloma Yáñez‐Sedeño
- Analytical Chemistry Dept., Faculty of ChemistryComplutense University of Madrid. 28040 Madrid Spain
| | - Susana Campuzano
- Analytical Chemistry Dept., Faculty of ChemistryComplutense University of Madrid. 28040 Madrid Spain
| | - José M. Pingarrón
- Analytical Chemistry Dept., Faculty of ChemistryComplutense University of Madrid. 28040 Madrid Spain
| |
Collapse
|
128
|
Nie Y, Li J, Liu Y, Zhang Q, Ma Q. A Visual FRET Immunofluorescent Biosensor for Ratiometric Parathyroid Hormone (1-84) Antigen Point-of-Care Detection. J Fluoresc 2020; 30:329-334. [PMID: 32020436 DOI: 10.1007/s10895-020-02502-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Accepted: 01/27/2020] [Indexed: 01/28/2023]
Abstract
Excessive secretion of PTH leads to disturbance of calcium and phosphorus metabolism in the body, which promotes bone, kidney, digestive system and nervous system diseases. Due to the short half-life of PTH, it becomes a difficult issue for PTH detection in the clinical diagnosis field. We explored a competitive immunofluorescent sensing mode based on FRET of two-color CdTe QDs for ratiometric PTH 1-84 antigen detection. The FRET effect and ratiometric fluorescence between the two-color CdTe QDs motivated accurate quantification of PTH 1-84 antigen concentration from 0.01 ng mL-1 to 0.08 ng mL-1 with a limit of detection of 3 pg mL-1. More importantly, under UV irradiation, samples with different concentrations of PTH 1-84 antigen achieved fluorescence visualization, which provides huge possibility for the practical application of PTH 1-84 antigen point-of-care detection.
Collapse
Affiliation(s)
- Yixin Nie
- Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China.,National Chemistry Experimental Teaching Demonstration Center, Jilin University, Changchun, 130012, China
| | - Jingting Li
- Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China.,National Chemistry Experimental Teaching Demonstration Center, Jilin University, Changchun, 130012, China
| | - Yang Liu
- Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China.,National Chemistry Experimental Teaching Demonstration Center, Jilin University, Changchun, 130012, China
| | - Qian Zhang
- Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China.,National Chemistry Experimental Teaching Demonstration Center, Jilin University, Changchun, 130012, China
| | - Qiang Ma
- Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China. .,National Chemistry Experimental Teaching Demonstration Center, Jilin University, Changchun, 130012, China.
| |
Collapse
|
129
|
Mahmoodi P, Rezayi M, Rasouli E, Avan A, Gholami M, Ghayour Mobarhan M, Karimi E, Alias Y. Early-stage cervical cancer diagnosis based on an ultra-sensitive electrochemical DNA nanobiosensor for HPV-18 detection in real samples. J Nanobiotechnology 2020; 18:11. [PMID: 31931815 PMCID: PMC6956556 DOI: 10.1186/s12951-020-0577-9] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Accepted: 01/07/2020] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND In several years ago, infection with human papillomaviruses (HPVs), have been prevalent in the worlds especially HPV type 18, can lead to cervical cancer. Therefore, rapid, accurate, and early diagnosis of HPV for successful treatment is essential. The present study describes the development of a selective and sensitive electrochemical biosensor base on DNA, for early detection of HPV-18. For this purpose, a nanocomposite of reduced graphene oxide (rGO) and multiwalled carbon nanotubes (MWCNTs) were electrodeposited on a screen-printed carbon electrode (SPCE). Then, Au nanoparticles (AuNPs) were dropped on a modified SPCE. Subsequently, single strand DNA (ssDNA) probe was immobilized on the modified electrode. The link attached between AuNPs and probe ssDNA provided by L-cysteine via functionalizing AuNPs (Cys-AuNPs). The differential pulse voltammetry (DPV) assay was also used to electrochemical measurement. The measurement was based on the oxidation signals of anthraquninone-2-sulfonic acid monohydrate sodium salt (AQMS) before and after hybridization between the probe and target DNA. RESULTS The calibration curve showed a linear range between 0.01 fM to 0.01 nM with a limit of detection 0.05 fM. The results showed that the optimum concentration for DNA probe was 5 µM. The good performance of the proposed biosensor was achieved through hybridization of DNA probe-modified SPCE with extracted DNA from clinical samples. CONCLUSIONS According to the investigated results, this biosensor can be introduced as a proprietary, accurate, sensitive, and rapid diagnostic method of HPV 18 in the polymerase chain reaction (PCR) of real samples.
Collapse
Affiliation(s)
- Pegah Mahmoodi
- Department of Biology, Mashhad Branch, Islamic Azad University, Mashhad, Iran
| | - Majid Rezayi
- Medical Toxicology Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
- Metabolic Syndrome Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
- Department of Medical Biotechnology and Nanotechnology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
| | - Elisa Rasouli
- Nanotechnology & Catalysis Research Centre, Institute of Postgraduate Studies, University Malaya, 50603, Kuala Lumpur, Malaysia
| | - Amir Avan
- Metabolic Syndrome Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mehrdad Gholami
- Department of Chemistry, Marvdasht Branch, Islamic Azad University, P.O. Box 465, Marvdasht, Iran
| | - Majid Ghayour Mobarhan
- Metabolic Syndrome Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Ehsan Karimi
- Department of Biology, Mashhad Branch, Islamic Azad University, Mashhad, Iran
| | - Yatima Alias
- Department of Chemistry, University of Malaya, 50603, Kuala Lumpur, Malaysia
| |
Collapse
|
130
|
Carneiro P, Morais S, do Carmo Pereira M. Biosensors on the road to early diagnostic and surveillance of Alzheimer's disease. Talanta 2020; 211:120700. [PMID: 32070618 DOI: 10.1016/j.talanta.2019.120700] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Revised: 12/21/2019] [Accepted: 12/28/2019] [Indexed: 12/22/2022]
Abstract
Alzheimer's disease is a debilitating and largely untreatable condition with subtle onset and slow progression over an extensive period of time, which culminate in increasing levels of disability. As Alzheimer's disease prevalence is expected to grow exponentially in the upcoming decades, there is an urgency to develop analytical technologies for the sensitive, reliable and cost-effective detection of Alzheimer's disease biomarkers. Biosensors are powerful analytical devices that translate events of biological recognition on physical or chemical transducers into electrical, thermal or optical signals. The high sensitivity and selectivity of biosensors associated with easy, rapid and low-cost determination of analytes have made this discipline one of the most intensively studied in the past decades. This review centers on recent advances, challenges and trends of Alzheimer's disease biosensing particularly in the effort to combine the unique properties of nanomaterials with biorecognition elements. In the last decade, impressive progresses have been made towards the development of biosensors, mainly electrochemical and optical, for detection of Alzheimer's disease biomarkers in the pico- and femto-molar range. Nonetheless, advances in multiplexed detection, robustness, stability and specificity are still necessary to ensure an accurate and differentiated diagnosis of this disease.
Collapse
Affiliation(s)
- Pedro Carneiro
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal; REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4200-072, Porto, Portugal
| | - Simone Morais
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr. António Bernardino de Almeida 431, 4200-072, Porto, Portugal.
| | - Maria do Carmo Pereira
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| |
Collapse
|
131
|
|
132
|
Idili A, Parolo C, Ortega G, Plaxco KW. Calibration-Free Measurement of Phenylalanine Levels in the Blood Using an Electrochemical Aptamer-Based Sensor Suitable for Point-of-Care Applications. ACS Sens 2019; 4:3227-3233. [PMID: 31789505 PMCID: PMC8097980 DOI: 10.1021/acssensors.9b01703] [Citation(s) in RCA: 69] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
By analogy to the revolution the "home glucose monitor" created in the treatment of diabetes, the availability of a modular, "platform" technology able to measure nearly any metabolite, biomarker, or drug "at-home" in unprocessed, finger-prick volumes of whole blood could revolutionize the monitoring and treatment of disease. Thus motivated, we have adapted here the electrochemical aptamer-based sensing platform to the problem of rapidly and conveniently measuring the level of phenylalanine in the blood, an ability that would aid the monitoring and management of phenylketonuria (PKU). To achieve this, we exploited a previously reported DNA aptamer that recognizes phenylalanine in complex with a rhodium-based "receptor" that improves affinity. We re-engineered this to undergo a large-scale, binding-induced conformational change before modifying it with a methylene blue redox reporter and attaching it to a gold electrode that supports the appropriate electrochemical interrogation. The resultant sensor achieves a useful dynamic range of 90 nM to 7 μM. When challenged with finger-prick-scale sample volumes of the whole blood (diluted 1000-fold to match the sensor's dynamic range), the device achieves the accurate (±20%), calibration-free measurement of blood phenylalanine levels in minutes.
Collapse
Affiliation(s)
- Andrea Idili
- Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States
- Center for Bioengineering, University of California Santa Barbara, Santa Barbara, California 93106, United States
| | - Claudio Parolo
- Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States
- Center for Bioengineering, University of California Santa Barbara, Santa Barbara, California 93106, United States
| | - Gabriel Ortega
- Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States
- Center for Bioengineering, University of California Santa Barbara, Santa Barbara, California 93106, United States
| | - Kevin W. Plaxco
- Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States
- Center for Bioengineering, University of California Santa Barbara, Santa Barbara, California 93106, United States
| |
Collapse
|
133
|
Salazar P, Fernández I, Rodríguez MC, Hernández-Creus A, González-Mora JL. One-step green synthesis of silver nanoparticle-modified reduced graphene oxide nanocomposite for H2O2 sensing applications. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.113638] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
134
|
Cardoso AR, de Sá M, Sales MGF. An impedimetric molecularly-imprinted biosensor for Interleukin-1β determination, prepared by in-situ electropolymerization on carbon screen-printed electrodes. Bioelectrochemistry 2019; 130:107287. [DOI: 10.1016/j.bioelechem.2019.04.017] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Revised: 04/20/2019] [Accepted: 04/20/2019] [Indexed: 12/24/2022]
|
135
|
Abstract
: Nanomaterial biosensors have revolutionized the entire scientific, technology, biomedical, materials science, and engineering fields. Among all nanomaterials, magnetic nanoparticles, microparticles, and beads are unique in offering facile conjugation of biorecognition probes for selective capturing of any desired analytes from complex real sample matrices (e.g., biofluids such as whole blood, serum, urine and saliva, tissues, food, and environmental samples). In addition, rapid separation of the particle-captured analytes by the simple use of a magnet for subsequent detection on a sensor unit makes the magnetic particle sensor approach very attractive. The easy magnetic isolation feature of target analytes is not possible with other inorganic particles, both metallic (e.g., gold) and non-metallic (e.g., silica), which require difficult centrifugation and separation steps. Magnetic particle biosensors have thus enabled ultra-low detection with ultra-high sensitivity that has traditionally been achieved only by radioactive assays and other tedious optical sources. Moreover, when traditional approaches failed to selectively detect low-concentration analytes in complex matrices (e.g., colorimetric, electrochemistry, and optical methods), magnetic particle-incorporated sensing strategies enabled sample concentration into a defined microvolume of large surface area particles for a straightforward detection. The objective of this article is to highlight the ever-growing applications of magnetic materials for the detection of analytes present in various real sample matrices. The central idea of this paper was to show the versatility and advantages of using magnetic particles for a variety of sample matrices and analyte types and the adaptability of different transducers with the magnetic particle approaches.
Collapse
|
136
|
Sanati A, Jalali M, Raeissi K, Karimzadeh F, Kharaziha M, Mahshid SS, Mahshid S. A review on recent advancements in electrochemical biosensing using carbonaceous nanomaterials. Mikrochim Acta 2019; 186:773. [PMID: 31720840 DOI: 10.1007/s00604-019-3854-2] [Citation(s) in RCA: 78] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Accepted: 09/19/2019] [Indexed: 12/29/2022]
Abstract
This review, with 201 references, describes the recent advancement in the application of carbonaceous nanomaterials as highly conductive platforms in electrochemical biosensing. The electrochemical biosensing is described in introduction by classifying biosensors into catalytic-based and affinity-based biosensors and statistically demonstrates the most recent published works in each category. The introduction is followed by sections on electrochemical biosensors configurations and common carbonaceous nanomaterials applied in electrochemical biosensing, including graphene and its derivatives, carbon nanotubes, mesoporous carbon, carbon nanofibers and carbon nanospheres. In the following sections, carbonaceous catalytic-based and affinity-based biosensors are discussed in detail. In the category of catalytic-based biosensors, a comparison between enzymatic biosensors and non-enzymatic electrochemical sensors is carried out. Regarding the affinity-based biosensors, scholarly articles related to biological elements such as antibodies, deoxyribonucleic acids (DNAs) and aptamers are discussed in separate sections. The last section discusses recent advancements in carbonaceous screen-printed electrodes as a growing field in electrochemical biosensing. Tables are presented that give an overview on the diversity of analytes, type of materials and the sensors performance. Ultimately, general considerations, challenges and future perspectives in this field of science are discussed. Recent findings suggest that interests towards 2D nanostructured electrodes based on graphene and its derivatives are still growing in the field of electrochemical biosensing. That is because of their exceptional electrical conductivity, active surface area and more convenient production methods compared to carbon nanotubes. Graphical abstract Schematic representation of carbonaceous nanomaterials used in electrochemical biosensing. The content is classified into non-enzymatic sensors and affinity/ catalytic biosensors. Recent publications are tabulated and compared, considering materials, target, limit of detection and linear range of detection.
Collapse
Affiliation(s)
- Alireza Sanati
- Department of Materials Engineering, Isfahan University of Technology, Isfahan, 84156-83111, Iran.,Department of Bioengineering, McGill University, Montreal, Quebec, H3A 0E9, Canada
| | - Mahsa Jalali
- Department of Bioengineering, McGill University, Montreal, Quebec, H3A 0E9, Canada
| | - Keyvan Raeissi
- Department of Materials Engineering, Isfahan University of Technology, Isfahan, 84156-83111, Iran
| | - Fathallah Karimzadeh
- Department of Materials Engineering, Isfahan University of Technology, Isfahan, 84156-83111, Iran
| | - Mahshid Kharaziha
- Department of Materials Engineering, Isfahan University of Technology, Isfahan, 84156-83111, Iran
| | - Sahar Sadat Mahshid
- Sunnybrook Research Institute, Sunnybrook Hospital, Toronto, Ontario, M4N 3M5, Canada.
| | - Sara Mahshid
- Department of Bioengineering, McGill University, Montreal, Quebec, H3A 0E9, Canada.
| |
Collapse
|
137
|
Birch CS, Bonwick GA. Advanced Glycation Endproducts (AGEs) in Food: Health Implications and Mitigation Strategies. MITIGATING CONTAMINATION FROM FOOD PROCESSING 2019:191-220. [DOI: 10.1039/9781788016438-00191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
Abstract
Controversy remains over the impact of advanced glycation endproducts (AGEs), not only in their formation, but also whether they actually come directly from food products or are generated by the body in response to ingestion of certain foods. This final chapter will take a different approach to food contaminants and look at the health impact of AGEs, regardless of whether they are directly ingested from food, autogenerated by the body as a consequence of underlying disease conditions or contribute to the aetiology of disease. AGEs are formed from food components or as a consequence of some disease states, such as type II diabetes or cardiovascular disease (CVD). As such these compounds are inextricably linked to the Maillard reaction and cooking conditions. Furthermore, processing-derived chemical contaminants in cooked foods are of concern to consumers. This chapter examines new research into naturally derived plant extracts as inhibitory agents on new dietary AGE (dAGE) formation and introduces practical approaches for the reduction of dAGE consumption in the daily diet. Understanding the pathogenic mechanisms of AGEs is paramount to developing strategies against diabetic and cardiovascular complications.
Collapse
|
138
|
|
139
|
Ferreira PC, Ataíde VN, Silva Chagas CL, Angnes L, Tomazelli Coltro WK, Longo Cesar Paixão TR, Reis de Araujo W. Wearable electrochemical sensors for forensic and clinical applications. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.115622] [Citation(s) in RCA: 74] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
140
|
Electrochemical DNA Biosensors Based on Labeling with Nanoparticles. NANOMATERIALS 2019; 9:nano9101361. [PMID: 31547500 PMCID: PMC6836269 DOI: 10.3390/nano9101361] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Revised: 09/18/2019] [Accepted: 09/20/2019] [Indexed: 02/07/2023]
Abstract
This work reviews the field of DNA biosensors based on electrochemical determination of nanoparticle labels. These labeling platforms contain the attachment of metal nanoparticles (NPs) or quantum dots (QDs) on the target DNA or on a biorecognition reporting probe. Following the development of DNA bioassay, the nanotags are oxidized to ions, which are determined by voltammetric methods, such as pulse voltammetry (PV) and stripping voltammetry (SV). The synergistic effects of NPs amplification (as each nanoprobe releases a large number of detectable ions) and the inherent sensitivity of voltammetric techniques (e.g., thanks to the preconcentration step of SV) leads to the construction of ultrasensitive, low cost, miniaturized, and integrated biodevices. This review focuses on accomplishments in DNA sensing using voltammetric determination of nanotags (such as gold and silver NPs, and Cd- and Pb-based QDs), includes published works on integrated three electrode biodevices and paper-based biosystems, and discusses strategies for multiplex DNA assays and signal enhancement procedures. Besides, this review mentions the electroactive NP synthesis procedures and their conjugation protocols with biomolecules that enable their function as labels in DNA electrochemical biosensors.
Collapse
|
141
|
Sharafeldin M, McCaffrey K, Rusling JF. Influence of antibody immobilization strategy on carbon electrode immunoarrays. Analyst 2019; 144:5108-5116. [PMID: 31373337 PMCID: PMC6711173 DOI: 10.1039/c9an01093a] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
We report here the influence of antibody immobilization strategy for protein immunosensors on screen printed carbon electrode arrays in terms of antibody binding activity, analytical sensitivity, limit of detection, and stability. Horseradish peroxidase (HRP) was the model analyte with anti-HRP immobilized on the sensors, and HRP activity was used for detection. Covalently immobilized anti-HRP antibodies on electrodes coated with chitosan, electrochemically reduced graphene oxide (rGO), and dense gold nanoparticle (AuNP) films had only 20-30% of the total immobilized antibodies active for binding. Active antibodies increased to 60% with passively adsorbed antibodies on bare electrodes, to 85% with oriented antibodies using protein A covalently immobilized on AuNP-coated carbon electrode, and to 98% when attached to protein A passively adsorbed onto bare electrodes. Passively adsorbed antibodies on bare electrodes lost activity in 1-2 days, but antibodies immobilized using other strategies remained relatively stable after 5 days. Covalent immobilization gave limits of detection (LOD) of 40 fg mL-1, while passively adsorbed antibodies or protein A on carbon electrodes had LODs 4-8 fg mL-1, but were unstable. Sensitivity was highest for antibodies covalently attached to AuNP electrodes (2.40 nA per log pg per mL) that also had highest antibody coverage, and decreased slightly when protein A on AuNP was used to orient antibodies. Passively adsorbed antibodies and oriented antibodies on protein A gave slightly lower sensitivities. Immobilization strategy or antibody orientation did not have a significant effect on LOD, but dynamic range increased as the number of active antibodies on sensor surfaces increased.
Collapse
Affiliation(s)
- Mohamed Sharafeldin
- Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA. and Analytical Chemistry Department, Faculty of Pharmacy, Zagazig University, Sharkia, Egypt
| | - Kira McCaffrey
- Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA.
| | - James F Rusling
- Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA. and Institute of Material Science, Storrs, CT 06269, USA and Department of Surgery and Neag Cancer Center, UConn Health, Farmington, CT 06032, USA and School of Chemistry, National University of Ireland at Galway, Ireland
| |
Collapse
|
142
|
Khanmohammadi A, Aghaie A, Vahedi E, Qazvini A, Ghanei M, Afkhami A, Hajian A, Bagheri H. Electrochemical biosensors for the detection of lung cancer biomarkers: A review. Talanta 2019; 206:120251. [PMID: 31514848 DOI: 10.1016/j.talanta.2019.120251] [Citation(s) in RCA: 204] [Impact Index Per Article: 34.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Revised: 08/08/2019] [Accepted: 08/09/2019] [Indexed: 01/05/2023]
Abstract
Cancer is one of the most widespread challenges and important diseases, which has the highest mortality rate. Lung cancer is the most common type of cancer, so that about 25% of all cancer deaths are related to the lung cancer. The lung cancer is classified as two different types with different treatment methodology: the small cell lung carcinoma and nonsmall cell lung carcinoma are two categories of the lung cancer. Since the lung cancer is often in the latent period in its early stages, therefore, early diagnosis of lung cancer has many challenges. Hence, there is a need for sensitive and reliable tools for preclinical diagnosis of lung cancer. Therefore, many detection methods have been employed for early detection of lung cancer. As lung cancer tumors growth in the body, the cancerous cells release numerous DNA, proteins, and metabolites as special biomarkers of the lung cancer. The levels of these biomarkers show the stages of the lung cancer. Therefore, detection of the biomarkers can be used for screening and clinical diagnosis of the lung cancer. There are numerous biomarkers for the lung cancer such as EGFR, CEA, CYFRA 21-1, ENO1, NSE, CA 19-9, CA 125 and VEGF. Nowadays, electrochemical methods are very attractive and useful in the lung cancer detections. So, in this paper, the recent advances and improvements (2010-2018) in the electrochemical detection of the lung cancer biomarkers have been reviewed.
Collapse
Affiliation(s)
- Akbar Khanmohammadi
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Ali Aghaie
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Ensieh Vahedi
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Ali Qazvini
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Mostafa Ghanei
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Abbas Afkhami
- Faculty of Chemistry, Bu-Ali Sina University, Hamedan, Iran
| | - Ali Hajian
- Institute of Sensor and Actuator Systems, TU Wien, Vienna, Austria
| | - Hasan Bagheri
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
143
|
Screen-printed electrodes modified with green-synthesized gold nanoparticles for the electrochemical determination of aminothiols. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.05.066] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
144
|
Girão AF, Serrano MC, Completo A, Marques PAAP. Do biomedical engineers dream of graphene sheets? Biomater Sci 2019; 7:1228-1239. [PMID: 30720810 DOI: 10.1039/c8bm01636d] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
During the past few years, graphene has outstandingly emerged as a key nanomaterial for boosting the performance of commercial, industrial and scientific related technologies. The popularity of this novel nanomaterial in biomedical engineering is due to its excellent biological, electronic, optical and thermal properties that, as a whole, surpass the features of commonly used biomaterials and consequently open a wide range of applications so far within the reach of science fiction. In this minireview, the potential of graphene and its based materials in the expanding biomedical field is highlighted with focus on groundbreaking diagnostic, monitoring and therapeutic strategies. Some of the major challenges related to the synthesis and safety of graphene-based materials are also briefly discussed because of their critical importance in bringing this class of carbon materials closer to the clinic.
Collapse
Affiliation(s)
- André F Girão
- TEMA, Department of Mechanical Engineering, University of Aveiro (UA), 3810-193 Aveiro, Portugal.
| | | | | | | |
Collapse
|
145
|
Filik H, Avan AA. Nanostructures for nonlabeled and labeled electrochemical immunosensors: Simultaneous electrochemical detection of cancer markers: A review. Talanta 2019; 205:120153. [PMID: 31450406 DOI: 10.1016/j.talanta.2019.120153] [Citation(s) in RCA: 72] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 07/09/2019] [Accepted: 07/12/2019] [Indexed: 12/14/2022]
Abstract
The simultaneous electrochemical determination of multiple tumor antigens has attracted a great deal of attention, which can effectively enhance the capability and accuracy of the analysis. Nanostructured materials mostly played a key major role in the electrochemical immunosensors fabrication and operation improvement. This review focused mainly on the protocols for using nanostructures to fabricate electrochemical (nonlabeled@label-free and labeled@sandwich-type) immunosensors. Furthermore, this review has also described the diverse classes of electroactive nanospecies which are a complementary part of any immunosensor that assists to reach the selectivity for the target antigen. Finally, the important analytical characteristics of the published immunosensors were discussed (electrochemical detection technique, linear range, and detection limit). Studies published between the years 2009-2018 have been included in this review.
Collapse
Affiliation(s)
- Hayati Filik
- Istanbul University-Cerrahpaşa, Faculty of Engineering, Department of Chemistry, 34320 Avcılar, Istanbul, Turkey.
| | - A Aslıhan Avan
- Istanbul University-Cerrahpaşa, Faculty of Engineering, Department of Chemistry, 34320 Avcılar, Istanbul, Turkey
| |
Collapse
|
146
|
Mollarasouli F, Kurbanoglu S, Ozkan SA. The Role of Electrochemical Immunosensors in Clinical Analysis. BIOSENSORS 2019; 9:E86. [PMID: 31324020 PMCID: PMC6784381 DOI: 10.3390/bios9030086] [Citation(s) in RCA: 121] [Impact Index Per Article: 20.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Revised: 07/04/2019] [Accepted: 07/05/2019] [Indexed: 01/12/2023]
Abstract
An immunosensor is a kind of affinity biosensor based on interactions between an antigen and specific antigen immobilized on a transducer surface. Immunosensors possess high selectivity and sensitivity due to the specific binding between antibody and corresponding antigen, making them a suitable platform for several applications especially in the medical and bioanalysis fields. Electrochemical immunosensors rely on the measurements of an electrical signal recorded by an electrochemical transducer and can be classed as amperometric, potentiometric, conductometric, or impedimetric depending on the signal type. Among the immunosensors, electrochemical immunosensors have been more perfected due to their simplicity and, especially their ability to be portable, and for in situ or automated detection. This review addresses the potential of immunosensors destined for application in clinical analysis, especially cancer biomarker diagnosis. The emphasis is on the approaches used to fabricate electrochemical immunosensors. A general overview of recent applications of the developed electrochemical immunosensors in the clinical approach is described.
Collapse
Affiliation(s)
- Fariba Mollarasouli
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560 Ankara, Turkey
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51666-16471, Iran
| | - Sevinc Kurbanoglu
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560 Ankara, Turkey
| | - Sibel A Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560 Ankara, Turkey.
| |
Collapse
|
147
|
The influence of the shape of Au nanoparticles on the catalytic current of fructose dehydrogenase. Anal Bioanal Chem 2019; 411:7645-7657. [PMID: 31286179 PMCID: PMC6881425 DOI: 10.1007/s00216-019-01944-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 05/08/2019] [Accepted: 05/24/2019] [Indexed: 11/02/2022]
Abstract
Graphite electrodes were modified with triangular (AuNTrs) or spherical (AuNPs) nanoparticles and further modified with fructose dehydrogenase (FDH). The present study reports the effect of the shape of these nanoparticles (NPs) on the catalytic current of immobilized FDH pointing out the different contributions on the mass transfer-limited and kinetically limited currents. The influence of the shape of the NPs on the mass transfer-limited and the kinetically limited current has been proved by using two different methods: a rotating disk electrode (RDE) and an electrode mounted in a wall jet flow-through electrochemical cell attached to a flow system. The advantages of using the wall jet flow system compared with the RDE system for kinetic investigations are as follows: no need to account for substrate consumption, especially in the case of desorption of enzyme, and studies of product-inhibited enzymes. The comparison reveals that virtually identical results can be obtained using either of the two techniques. The heterogeneous electron transfer (ET) rate constants (kS) were found to be 3.8 ± 0.3 s-1 and 0.9 ± 0.1 s-1, for triangular and spherical NPs, respectively. The improvement observed for the electrode modified with AuNTrs suggests a more effective enzyme-NP interaction, which can allocate a higher number of enzyme molecules on the electrode surface. Graphical abstract The shape of gold nanoparticles has a crucial effect on the catalytic current related to the oxidation of D-(-)-fructose to 5-keto-D-(-)-fructose occurring at the FDH-modified electrode surface. In particular, AuNTrs have a higher effect compared with the spherical one.
Collapse
|
148
|
Dincer C, Bruch R, Costa-Rama E, Fernández-Abedul MT, Merkoçi A, Manz A, Urban GA, Güder F. Disposable Sensors in Diagnostics, Food, and Environmental Monitoring. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2019; 31:e1806739. [PMID: 31094032 DOI: 10.1002/adma.201806739] [Citation(s) in RCA: 307] [Impact Index Per Article: 51.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Revised: 03/29/2019] [Indexed: 05/18/2023]
Abstract
Disposable sensors are low-cost and easy-to-use sensing devices intended for short-term or rapid single-point measurements. The growing demand for fast, accessible, and reliable information in a vastly connected world makes disposable sensors increasingly important. The areas of application for such devices are numerous, ranging from pharmaceutical, agricultural, environmental, forensic, and food sciences to wearables and clinical diagnostics, especially in resource-limited settings. The capabilities of disposable sensors can extend beyond measuring traditional physical quantities (for example, temperature or pressure); they can provide critical chemical and biological information (chemo- and biosensors) that can be digitized and made available to users and centralized/decentralized facilities for data storage, remotely. These features could pave the way for new classes of low-cost systems for health, food, and environmental monitoring that can democratize sensing across the globe. Here, a brief insight into the materials and basics of sensors (methods of transduction, molecular recognition, and amplification) is provided followed by a comprehensive and critical overview of the disposable sensors currently used for medical diagnostics, food, and environmental analysis. Finally, views on how the field of disposable sensing devices will continue its evolution are discussed, including the future trends, challenges, and opportunities.
Collapse
Affiliation(s)
- Can Dincer
- Department of Bioengineering, Imperial College London, Royal School of Mines, SW7 2AZ, London, UK
- University of Freiburg, Freiburg Center for Interactive Materials and Bioinspired Technologies (FIT), 79110, Freiburg, Germany
- Laboratory for Sensors, Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany
| | - Richard Bruch
- University of Freiburg, Freiburg Center for Interactive Materials and Bioinspired Technologies (FIT), 79110, Freiburg, Germany
- Laboratory for Sensors, Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany
| | - Estefanía Costa-Rama
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, 4249-015, Porto, Portugal
- Departamento de Química Física y Analítica, Universidad de Oviedo, 33006, Oviedo, Spain
| | | | - Arben Merkoçi
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and The Barcelona Institute of Science and Technology, 08193, Barcelona, Spain
- ICREA, 08010, Barcelona, Spain
| | - Andreas Manz
- Korea Institute of Science and Technology in Europe, 66123, Saarbrücken, Germany
| | - Gerald Anton Urban
- Laboratory for Sensors, Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany
- University of Freiburg, Freiburg Materials Research Center (FMF), 79104, Freiburg, Germany
| | - Firat Güder
- Department of Bioengineering, Imperial College London, Royal School of Mines, SW7 2AZ, London, UK
| |
Collapse
|
149
|
Deroco PB, Fatibello‐Filho O, Arduini F, Moscone D. Effect of Different Carbon Blacks on the Simultaneous Electroanalysis of Drugs as Water Contaminants Based on Screen‐printed Sensors. ELECTROANAL 2019. [DOI: 10.1002/elan.201900042] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Patricia Batista Deroco
- Department of ChemistryFederal University of São Carlos, C.P. 676 13560-970 São Carlos–SP Brazil
| | - Orlando Fatibello‐Filho
- Department of ChemistryFederal University of São Carlos, C.P. 676 13560-970 São Carlos–SP Brazil
| | - Fabiana Arduini
- Department of Chemical Science and TechnologiesUniversity of Rome “Tor Vergata” Via della Ricerca Scientifica 00133 Rome Italy
| | - Danila Moscone
- Department of Chemical Science and TechnologiesUniversity of Rome “Tor Vergata” Via della Ricerca Scientifica 00133 Rome Italy
| |
Collapse
|
150
|
Stanković DM, Ognjanović M, Jović M, Cuplić V, Lesch A, Girault HH, Gavrović Jankulović M, Antić B. Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet‐printed CNT Electrodes‐droplet Based Paracetamol Detection in Biological Fluids for “Point‐of‐care” Applications. ELECTROANAL 2019. [DOI: 10.1002/elan.201900129] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Affiliation(s)
- Dalibor M. Stanković
- The “Vinča” Institute of Nuclear SciencesUniversity of Belgrade, POB 522 11001 Belgrade Serbia
| | - Miloš Ognjanović
- The “Vinča” Institute of Nuclear SciencesUniversity of Belgrade, POB 522 11001 Belgrade Serbia
| | - Milica Jović
- Laboratory of Physical and Analytical Electrochemistry (LEPA)EPFL Valais Wallis Rue de l'Industrie 17 CH-1951 Sion Switzerland
| | - Valentina Cuplić
- Faculty of ChemistryUniversity of Belgrade Studentski trg 12–16 11000 Belgrade Serbia
| | - Andreas Lesch
- Department of Industrial Chemistry “Toso Montanari”University of Bologna Viale del Risorgimento 4 40136 Bologna Italy
| | - Hubert H. Girault
- Laboratory of Physical and Analytical Electrochemistry (LEPA)EPFL Valais Wallis Rue de l'Industrie 17 CH-1951 Sion Switzerland
| | | | - Bratislav Antić
- The “Vinča” Institute of Nuclear SciencesUniversity of Belgrade, POB 522 11001 Belgrade Serbia
| |
Collapse
|