101
|
Abstract
The introduction of the Toronto stentless porcine valve (SPV) (St. Jude, Minneapolis, MN), recently approved by the Food and Drug Administration following a 6-year multi-institutional clinical trial from 1991 to 1997, reflects an evolutionary pursuit of an ideal valve substitute, namely, low thrombogenicity, freedom from anticoagulation, durability, easy availability, resistance to infection, and easy implantability. Currently, four different types of valve replacement have been time tested: mechanical valves, cryopreserved aortic homograft, stented heterograft, and pulmonary autograft (Ross procedure), and none of the available valve substitutes meet all the criteria of an ideal valve. The mechanical valve's favorable properties of durability and easy implantability are susceptible to thrombus formation, which requires lifelong anticoagulation. Although the aortic homografts are durable, with low incidence of infection and thrombogenicity, their widespread application has been limited by the lack of availability. The pulmonary autograft, with its native aortic valve properties, has been shunned by some surgeons because it requires a demanding technical expertise in implantation and needs an allograft in the pulmonary position. Stented xenografts are characterized by "off-the-shelf" availability, freedom from anticoagulation, easy implantability, and low incidence of infection. Its major drawback has been its limited durability. Another limitation is its residual transvalvular gradient. A modified version, a stentless xenograft, has been introduced to improve hemodynamic profiles in the hope of subsequent superior structural durability and patient survival. Two valves have been approved by the Food and Drug Administration, the Toronto SPV and the Freestyle valve (Medtronic, Minneapolis, MN). At The Methodist Hospital and the Baylor College of Medicine, the Toronto SPV stentless valve has been our stentless xenograft valve of choice. We therefore review the historical evolution, design advantages, surgical techniques, and clinical outcomes of this valve.
Collapse
Affiliation(s)
- S Z Park
- Division of Cardiothoracic Surgery, Baylor College of Medicine, Houston, Texas 77030, USA
| | | |
Collapse
|
102
|
Khan SS, Siegel RJ, DeRobertis MA, Blanche CE, Kass RM, Cheng W, Fontana GP, Trento A. Regression of hypertrophy after Carpentier-Edwards pericardial aortic valve replacement. Ann Thorac Surg 2000; 69:531-5. [PMID: 10735693 DOI: 10.1016/s0003-4975(99)01389-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
BACKGROUND The purpose of this study was to determine whether significant regression of left ventricular hypertrophy is seen after implantation of small sizes (19 to 23 mm) of the Carpentier-Edwards (CE) pericardial valve, a stented pericardial valve. METHODS Echocardiograms and electrocardiograms (ECGs) were performed at least 1 year after surgery (mean 18 months) in patients with 19-, 21-, and 23-mm CE pericardial aortic valves and compared with preoperative echocardiograms and ECGs. RESULTS A total of 41 patients, mean age 79 +/- 9 years (range 46 to 93 years), were studied, including 7 19-mm, 22 21-mm, and 12 23-mm patients. The mean postoperative gradient was 22 +/- 7 mm Hg for 19-mm valves, 18 +/- 5 mm Hg for 21-mm valves, and 16 +/- 4 mm Hg for 23-mm valves. The postoperative valve areas were 1.1 +/- 0.3 cm2 for the 19-mm, 1.3 +/- 0.3 cm2 for the 21-mm, and 1.5 +/- 0.4 cm2 for the 23-mm valves. Left ventricular end diastolic diameter, end systolic diameter, septal thickness, and posterior wall thickness all decreased significantly (p <0.05) postoperatively. The proportion of patients with significant left ventricular hypertrophy on ECG decreased from 63% to 47% (p = 0.001). Left ventricular mass decreased significantly by echocardiography from 265 g preoperatively to 208 g postoperatively (p = 0.004). Left ventricular mass decreased for each valve size, and the greatest absolute reduction in mass occurred in the 19-mm valve recipients. CONCLUSIONS Implantation of the 19-, 21-, and 23-mm CE pericardial valves results in significant reductions in left ventricular mass. These findings suggest that stented pericardial valves can be used in the small aortic root without the need for aortic root enlargement procedures.
Collapse
Affiliation(s)
- S S Khan
- Division of Cardiology, Cedars-Sinai Medical Center, Los Angeles, California 90048, USA.
| | | | | | | | | | | | | | | |
Collapse
|
103
|
Natsuaki M, Itoh T, Okazaki Y, Ishida H, Hamada M, Rikitake K, Naitoh K. Evaluation of postoperative cardiac function and long-term results in patients after aortic valve replacement for aortic valve disease with increased left ventricular mass. THE JAPANESE JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY : OFFICIAL PUBLICATION OF THE JAPANESE ASSOCIATION FOR THORACIC SURGERY = NIHON KYOBU GEKA GAKKAI ZASSHI 2000; 48:30-8. [PMID: 10714018 DOI: 10.1007/bf03218082] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
OBJECTIVE This clinical study was designed to evaluate the postoperative cardiac function in patients after aortic valve replacement for aortic valve disease with increased left ventricular mass. METHODS Aortic valve replacement was performed in 117 patients using the St. Jude Medical valve. Their valve lesion was aortic regurgitation in 71, and aortic stenosis in 46. The mean value of the left ventricular mass index was 272 g/m2. The 117 patients were subdivided into 4 groups according to their preoperative left ventricular mass index-Group I (n = 35) with aortic regurgitation and a large left ventricular mass index (> or = 273 g/m2), Group II (n = 36) with aortic regurgitation and a small left ventricular mass index Group III (n = 19) with aortic stenosis and a large left ventricular mass index, and Group IV (n = 27) with aortic stenosis and a small left ventricular mass index. The cardiac function was evaluated by radionuclide ventriculography. RESULTS In a comparative study of postoperative parameters among the 4 groups, the postoperative systolic and diastolic parameters of Group I patients were more significantly impaired compared with these parameters of the other 3 groups. The postoperative values the left ventricular mass index were significantly higher in Group I than in the other 3 groups. The 10-year survival rate was significantly lower in Group I than in the other 3 groups (30 +/- 22% in Group I). CONCLUSION Aortic valve replacement is recommended for patients with eccentric hypertrophy in the adequate clinical phase of patients whose left ventricular mass index is less than 272 g/m2.
Collapse
Affiliation(s)
- M Natsuaki
- Department of Thoracic and Cardiovascular Surgery, Saga Medical School, Japan
| | | | | | | | | | | | | |
Collapse
|
104
|
Pibarot P, Dumesnil JG, Leblanc MH, Cartier P, Métras J. Changes in left ventricular mass and function after aortic valve replacement: a comparison between stentless and stented bioprosthetic valves. J Am Soc Echocardiogr 1999; 12:981-7. [PMID: 10552360 DOI: 10.1016/s0894-7317(99)70152-5] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The objective of this study was to compare stentless bioprostheses with stented bioprostheses with regard to the postoperative changes in left ventricular (LV) mass and function. Forty patients with aortic stenosis undergoing valve replacement with a stentless (20 patients) or a stented (20 patients) bioprosthesis were evaluated early (baseline), 1 year, and 2 years after operation. Left ventricular mass index was calculated with the corrected American Society of Echocardiography formula. The relative changes between end-diastole and end-systole in LV mid-wall radius, length, and volume (ejection fraction) were determined with a previously validated model for dynamic geometry of the left ventricle. Overall, a significant decrease was found in LV mass index (from 155 +/- 30 to 112 +/- 23 g/m(2); P <.001) and a significant increase in longitudinal shortening (from 0.12 +/- 0.11 to 0.22 +/- 0.08; P <. 001), and ejection fractions (from 0.67 +/- 0.11 to 0.71 +/- 0.10; P =.017). No significant change was found in the mid-wall radius shortening fraction. Two years after surgery, the extent of LV mass regression was greater in stentless bioprostheses (-51 +/- 18 vs -35 +/- 17 g/m(2); P =.01), though the average mass index was similar in both groups (114 +/- 26 vs 110 +/- 20 g/m(2)). Also at 2 years, the longitudinal shortening fraction was greater in patients with a stentless bioprosthesis (0.25 +/- 0.07 vs 0.18 +/- 0.08; P =.03). In conclusion, this study suggests that the superior hemodynamic performance of stentless bioprostheses may have some benefits with regard to LV mass regression and function after aortic valve replacement. The significance of these benefits in terms of prognosis remains to be determined.
Collapse
Affiliation(s)
- P Pibarot
- Quebec Heart Institute/Laval Hospital, Department of Medicine, Laval University, Ste-Foy, Quebec, Canada.
| | | | | | | | | |
Collapse
|
105
|
Pibarot P, Dumesnil JG, Jobin J, Cartier P, Honos G, Durand LG. Hemodynamic and physical performance during maximal exercise in patients with an aortic bioprosthetic valve: comparison of stentless versus stented bioprostheses. J Am Coll Cardiol 1999; 34:1609-17. [PMID: 10551713 DOI: 10.1016/s0735-1097(99)00360-5] [Citation(s) in RCA: 96] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVES The objective of this study was to compare stentless bioprostheses with stented bioprostheses with regard to their hemodynamic behavior during exercise. BACKGROUND Stentless aortic bioprostheses have better hemodynamic performances at rest than stented bioprostheses, but very few comparisons were performed during exercise. METHODS Thirty-eight patients with normally functioning stentless (n = 19) or stented (n = 19) bioprostheses were submitted to a maximal ramp upright bicycle exercise test. Valve effective orifice area and mean transvalvular pressure gradient at rest and during peak exercise were successfully measured using Doppler echocardiography in 30 of the 38 patients. RESULTS At peak exercise, the mean gradient increased significantly less in stentless than in stented bioprostheses (+5 +/- 3 vs. +12 +/- 8 mm Hg; p = 0.002) despite similar increases in mean flow rates (+137 +/- 58 vs. +125 +/- 65 ml/s; p = 0.58); valve area also increased but with no significant difference between groups. Despite this hemodynamic difference, exercise capacity was not significantly different, but left ventricular (LV) mass and function were closer to normal in stentless bioprostheses. Overall, there was a strong inverse relation between the mean gradient during peak exercise and the indexed valve area at rest (r = 0.90). CONCLUSIONS Hemodynamics during exercise are better in stentless than stented bioprostheses due to the larger resting indexed valve area of stentless bioprostheses. This is associated with beneficial effects with regard to LV mass and function. The relation found between the resting indexed valve area and the gradient during exercise can be used to project the hemodynamic behavior of these bioprostheses at the time of operation. It should thus be useful to select the optimal prosthesis given the patient's body surface area and level of physical activity.
Collapse
Affiliation(s)
- P Pibarot
- Quebec Heart Institute/Laval Hospital, Laval University, Ste-Foy, Quebec, Canada.
| | | | | | | | | | | |
Collapse
|
106
|
Dellgren G, Eriksson MJ, Blange I, Brodin LA, Rådegran K, Sylvén C. Angiotensin-converting enzyme gene polymorphism influences degree of left ventricular hypertrophy and its regression in patients undergoing operation for aortic stenosis. Am J Cardiol 1999; 84:909-13. [PMID: 10532509 DOI: 10.1016/s0002-9149(99)00464-6] [Citation(s) in RCA: 49] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Insertion (I)/deletion (D) polymorphism of the angiotensin-converting enzyme (ACE) gene has been associated with increased left ventricular hypertrophy (LVH) in patients with cardiomyopathy and congestive heart failure. Patients with aortic stenosis (AS) have varying degrees of LVH at a given valve area. The aim of this study was to examine the relation between ACE gene polymorphism and the degree of LVH in patients undergoing operation for AS. Eighty-two patients who underwent operation for AS with a stentless valve were followed prospectively with echocardiographic assessments of left ventricular mass index (LVMI). ACE gene polymorphism was determined by polymerase chain reaction. The genotype (DD, ID, and II) frequency was the same as in healthy controls. The pressure difference across the aortic valve did not differ between genotypes. Patients with the DD genotype of the ACE gene had a higher LVMI (197 +/- 47 g/m2) preoperatively than those with ID (175 +/- 41 g/m2) or II (155 +/- 43 g/m2) genotypes (p = 0.01). LVMI decreased significantly in DD (p <0.001) and ID (p <0.001) genotypes but not in the II genotype during follow-up (mean 15 months). There was a significant difference in regression of LVMI over time between genotypes (p = 0.0056), with no significant difference between genotypes at follow-up. The DD genotype of the ACE gene is associated with increased preoperative LVH in patients treated surgically for AS. The DD genotype appears to be an important factor which increases hypertrophic myocardial reactivity to pressure overload.
Collapse
Affiliation(s)
- G Dellgren
- Department of Cardiothoracic Surgery, Karolinska Institute, Huddinge University Hospital, Sweden.
| | | | | | | | | | | |
Collapse
|
107
|
Niwaya K, Elkins RC, Knott-Craig CJ, Santangelo KL, Cannon MB, Lane MM. Normalization of left ventricular dimensions after Ross operation with aortic annular reduction. Ann Thorac Surg 1999; 68:812-8; discussion 818-9. [PMID: 10509967 DOI: 10.1016/s0003-4975(99)00765-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Fifty-seven patients (August 1995 to November 1998) with a dysplastic dilated aortic root, a relative contraindication to the Ross operation, received an extended Ross operation with aortic annulus reduction and external cuff fixation (age 14-54 years). To assess the efficacy of these operations, echocardiographic assessment of autograft valve function and left ventricular function and dimensions were reviewed. METHODS Preoperative and postoperative assessment of 27 patients with aortic insufficiency (AI group) and 30 patients with aortic stenosis (>20 mm Hg peak gradient) and aortic insufficiency (AS group) were compared. Aortic annulus size, valvular gradient, valve insufficiency, left ventricular dimensions at end-systole and end-diastole, left ventricular fractional shortening, and left ventricular mass were assessed. RESULTS There was one late death. Aortic annulus size, degree of AI, left ventricular internal dimensions, and left ventricular mass were all significantly reduced (p<0.05) postoperatively in the AI group. Mean peak pressure gradients for this group were 6.8+/-6.7 mm Hg before operation and 8.7+/-6.4 mm Hg at 1 year after operation. Peak pressure gradient, aortic annulus size, degree of AI, left ventricular internal dimensions, and left ventricular mass were significantly reduced (p<0.05) in the AS group. Mean fractional shortening was within normal limits pre- and postoperatively for both groups. CONCLUSIONS Regression of left ventricular dilatation and hypertrophy, excellent autograft valve function, and survival suggest that this modification of the Ross operation may be offered to patients with a dysplastic aortic root requiring aortic valve replacement.
Collapse
Affiliation(s)
- K Niwaya
- Section of Thoracic and Cardiovascular Surgery, University of Oklahoma Health Sciences Center, Oklahoma City 73190, USA
| | | | | | | | | | | |
Collapse
|
108
|
Gross C, Harringer W, Beran H, Mair R, Sihorsch K, Hofmann R, Brücke P. Aortic valve replacement: is the stentless xenograft an alternative to the homograft? Midterm results. Ann Thorac Surg 1999; 68:919-24. [PMID: 10509984 DOI: 10.1016/s0003-4975(99)00535-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND This study was performed to assess the midterm clinical results after aortic valve replacement (AVR) with stentless xenograft (SX) compared with cryopreserved aortic or pulmonary homografts (HX). METHODS In 139 patients (<60 years) undergoing elective AVR, 59 HX and 80 SX were inserted. All patients were followed clinically and by color flow Doppler echocardiography for 45+/-12 months (range 31-58 months). RESULTS There were 5 in-hospital deaths (3.5%): 4 HX and 1 SX (p = NS). The mean gradient was 6+/-2 mm Hg in HX versus 13+/-6 mm Hg in SX (p<0.001) and remained unchanged during follow-up. Actuarial survival (HX 77%, SX 80%), freedom from endocarditis (HX 91%, SX 99%), freedom from thromboembolic events (HX 98%, SX 90%), and freedom from reoperation (HX 98%, SX 100%) were comparable between groups after 58 months. CONCLUSIONS Despite slightly higher transvalvular gradients, the stentless aortic valve achieved excellent midterm results, when compared with homografts.
Collapse
Affiliation(s)
- C Gross
- Department of Surgery I and Cardiology, General Hospital Linz, Austria
| | | | | | | | | | | | | |
Collapse
|
109
|
González-Juanatey JR, Fernández MV, Sampedro FG, García-Acuña JM, García-Bengoechea JB, Cendon AA, de La Peña MG. Haemodynamic performance of aortic pericardial bioprostheses and bileaflet prostheses at rest and during exercise: implications for the surgical management of patients with small aortic roots. Heart 1999; 82:149-55. [PMID: 10409527 PMCID: PMC1729145 DOI: 10.1136/hrt.82.2.149] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
OBJECTIVE To determine the haemodynamic behaviour, at rest and during exercise, of aortic valve pericardial bioprostheses and different sizes of bileaflet prosthesis. DESIGN Observational study. SETTING Tertiary medical centre. PATIENTS AND INTERVENTIONS 74 patients (33 women, 41 men; mean age 64 years) in whom 40 pericardial bioprostheses and 34 bileaflet prostheses sized 19, 21, or 23 mm had been implanted to replace aortic valves. MAIN OUTCOME MEASURES Doppler echocardiography at rest and at peak exercise, between 12 and 47 months after surgery. RESULTS All patients achieved a significant increase in heart rate, systolic blood pressure, and cardiac output with exercise. Transvalvar pressure fall, valve area, and left ventricular systolic and diastolic function indices also underwent significant changes with exercise. Reductions in peak and mean transvalvar pressure, at rest and at peak exercise, were greater in patients with small valves (p < 0.05). Valve areas and effective area index were greater in the patients with larger valves (p < 0.001). There were no significant differences between patients with mechanical and biological prostheses with regard to transvalvar pressure fall and valve areas at rest and at peak exercise. CONCLUSIONS 19 mm and 21 mm aortic prostheses and bioprostheses continue to create significant obstruction, particularly with exercise.
Collapse
Affiliation(s)
- J R González-Juanatey
- Department of Cardiology, Galician General Hospital and University of Santiago Faculty of Medicine, 15705 Santiago de Compostela, Spain.
| | | | | | | | | | | | | |
Collapse
|
110
|
Maselli D, Pizio R, Bruno LP, Di Bella I, De Gasperis C. Left ventricular mass reduction after aortic valve replacement: homografts, stentless and stented valves. Ann Thorac Surg 1999; 67:966-71. [PMID: 10320236 DOI: 10.1016/s0003-4975(99)00215-5] [Citation(s) in RCA: 63] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND We studied the effect of four different types of prosthetic aortic valves on time course and extent of regression of left ventricular hypertrophy after aortic valve replacement for aortic stenosis. METHODS Four groups of 10 patients each were randomly assigned to receive: (1) aortic homograft preserved in antibiotic solution at 4 degrees C, (2) Toronto stentless porcine valve, (3) Medtronic Freestyle stentless valve, or (4) Medtronic Intact aortic valve. The left ventricular mass index, effective orifice area index, and peak and mean transaortic gradients were measured by Doppler echocardiography before the operation and 8 months postoperatively. RESULTS The hemodynamic performance indices were much better for the homograft and stentless valves than for the stented one. The absolute left ventricular mass index reduction was greater in the homograft group compared with the Intact (p = 0.0004) and Toronto (p = 0.007) groups. The extent of percent left ventricular mass index reduction was greater only in the homograft group versus Intact group (p = 0.005). The multilinear regression analysis showed that the only predictors of a larger percentage of left ventricular mass index reduction were the homograft type, a higher valve size index, and a higher preoperative left ventricular mass index. CONCLUSIONS When a stentless or homograft aortic valve was used instead of a stented valve to replace a stenotic aortic valve there was more complete or at least faster regression of left ventricular hypertrophy. The hemodynamic performance of stentless porcine valves was similar to that of aortic homografts, nevertheless the aortic homografts preserved in antibiotic solution offered a faster regression of left ventricular hypertrophy during the same period of time.
Collapse
Affiliation(s)
- D Maselli
- Department of Cardiac Surgery, Ospedale Maggiore della Carità, Novara, Italy.
| | | | | | | | | |
Collapse
|
111
|
Jin XY, Pillai R, Westaby S. Medium-term determinants of left ventricular mass index after stentless aortic valve replacement. Ann Thorac Surg 1999; 67:411-6. [PMID: 10197662 DOI: 10.1016/s0003-4975(98)01134-5] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND This study aimed to investigate the risk factors for elevated left ventricular mass index 3 to 5 years after stentless aortic valve replacement, and to elucidate the underlying physiologic mechanisms. METHODS Eighty-nine patients (age, 76 +/- 6 years, 51 males) having a stentless porcine valve for aortic stenosis (n = 76) or regurgitation (n = 13) were prospectively studied by Doppler echocardiography 3 to 5 years after operation. Left ventricular systolic function, mass index, blood pressure, cardiac rhythm, and New York Heart Association function class were all determined. Stentless valve effective orifice area, mean pressure drop, and the presence and degree of aortic regurgitation were quantified. RESULTS The mean stentless aortic valve size was 24 +/- 2 mm. At follow-up time of 45 +/- 9 months, effective orifice area index was 1.2 +/- 0.35 cm2 x m(-2), and mean pressure drop was 5.7 +/- 3.8 mm Hg. Left ventricular mass index was 128 +/- 47 g x m(-2), and ejection fraction was 63% +/- 14%. Multivariant analysis showed a greater left ventricular mass index to be associated with nonsinus rhythm (versus sinus) (163 +/- 8 versus 131 +/- 7 g x m(-2)), greater pulse pressure (> 84 mm Hg) (161 +/- 7 versus 133 +/- 7 g x m(-2)), New York Heart Association class II or III (versus class I) (166 +/- 10 versus 128 +/- 5 g x m(-2)), and male sex (versus female) (160 +/- 7 versus 134 +/- 8 g x m(-2)), all p < 0.01. Mean pressure drop (> 8 mm Hg), effective orifice area index (< 1.0 cm2 x m(-2)), the presence of mild regurgitation of the stentless valve, or the type of previous valve disease were insignificant determinants of left ventricular mass index. CONCLUSIONS Three to five years after the implantation, stentless aortic valve hemodynamics remain excellent. Left ventricular hypertrophy caused by previous native aortic valve disease had largely regressed. However, patient-related factors, particularly systemic blood pressure, cardiac rhythm, and function, are significant causes of late residual left ventricular hypertrophy. Thus, continued medical care and earlier surgical intervention may further improve the outlook for these patients.
Collapse
Affiliation(s)
- X Y Jin
- Department of Cardiac Surgery, Oxford Heart Centre, John Radcliffe Hospital, Headington, England
| | | | | |
Collapse
|
112
|
Hvass U, Palatianos GM, Frassani R, Puricelli C, O'Brien M. Multicenter study of stentless valve replacement in the small aortic root. J Thorac Cardiovasc Surg 1999; 117:267-72. [PMID: 9918967 DOI: 10.1016/s0022-5223(99)70422-8] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
OBJECTIVE A clinical study was conducted to evaluate the results of stentless porcine valves in patients with a small aortic root (19- and 21-mm aortic anulus). METHODS Of 567 patients, from 4 surgical institutions, 171 patients (30.1%) had a small aortic root, comprising 163 cases with calcified aortic stenosis and 8 cases with predominant valvular insufficiency. Sixty patients had associated mitral or coronary lesions. Mean age was 72 +/- 4.2 years. Forty-seven patients with a small aortic root had a 19-mm anulus, and 124 patients had a 21-mm anulus. The body surface area was, respectively, 1.55 +/- 0.2 m2 and 1.78 +/- 0.45 m2. Hemodynamic evaluation of the stentless valve comprised serial measures of mean gradients, effective orifice area, and left ventricular mass reduction. Complication rates for secondary events were evaluated over a 6-year period. RESULTS The hospital mortality rate was 3.5%. The mean gradients after the first year were 9 +/- 2 mm Hg and 6 +/- 1.7 mm Hg in patients with a 19-mm and a 21-mm anulus, respectively. Effective orifice area was 1.45 +/- 0.3 cm2 and 1.72 +/- 0.4 cm2. Gradients and surfaces remained stable throughout the study period. Aortic regurgitation was zero to trace. Left ventricular mass at discharge and at 1 year were, respectively, 296 +/- 127 g and 215 +/- 102 g for patients with a 19-mm anulus and 281 +/- 75 g and 236 +/- 15 g for patients with a 21-mm anulus. CONCLUSIONS Stentless valves are a suitable device for elderly patients with small aortic roots, which leave only mild residual obstruction.
Collapse
Affiliation(s)
- U Hvass
- Hopital Bichat, Paris, France
| | | | | | | | | |
Collapse
|
113
|
Lund O, Chandrasekaran V, Grocott-Mason R, Elwidaa H, Mazhar R, Khaghani A, Mitchell A, Ilsley C, Yacoub MH. Primary aortic valve replacement with allografts over twenty-five years: valve-related and procedure-related determinants of outcome. J Thorac Cardiovasc Surg 1999; 117:77-90; discussion 90-1. [PMID: 9869760 DOI: 10.1016/s0022-5223(99)70471-x] [Citation(s) in RCA: 122] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
OBJECTIVES Allografts offer many advantages over prosthetic valves, but allograft durability varies considerably. METHODS From 1969 through 1993, 618 patients aged 15 to 84 years underwent their first aortic valve replacement with an aortic allograft. Concomitant surgery included aortic root tailoring (n = 58), replacement or tailoring of the ascending aorta (n = 56), and coronary artery bypass grafting (n = 87). Allograft implantation was done by means of a "freehand" subcoronary technique (n = 551) or total root replacement (n = 67). The allografts were antibiotic sterilized (n = 479), cryopreserved (n = 12), or viable (unprocessed, harvested from brain-dead multiorgan donors or heart transplant recipients, n = 127). Maximum follow-up was 27.1 years. RESULTS Thirty-day mortality was 5.0%, and crude survival was 67% and 35% at 10 and 20 years. Ten- and 20-year rates of freedom from complications were as follows: endocarditis, 93% and 89%; primary tissue failure, 62% and 18%; and redo aortic valve replacement, 81% and 35%. Multivariable Cox analyses identified several valve- and procedure-related determinants: rising allograft donor age and antibiotic-sterilized allograft for mortality; donor more than 10 years older than patient for endocarditis; rising donor age minus patient age, rising implantation time (from harvest to aortic valve replacement), and donor age more than 65 years for tissue failure; and rising donor age minus patient age, young patient age, rising implantation time, and subcoronary implantation preceded by aortic root tailoring for redo aortic valve replacement. Estimated 10- and 20-year rates of freedom from tissue failure for a 70-year-old patient with a viable valve from a 30-year-old donor and no other risk factors were 91% and 64%; the figures were 71% and 20% if the donor age was 65 years. The rates of freedom from tissue failure for a 30-year-old patient with a 30-year-old donor were 82% and 39%; the figures were 49% and 3% with a 65-year-old donor. Beneficial influences of a viable valve were largely covered by short harvest time (no delay for allografts from brain dead organ donors or heart transplant recipients) and short implantation time. CONCLUSIONS Primary allograft aortic valve replacement can give acceptable results for up to 25 years. The late results can be improved by the use of a viable allograft, by matching patient and donor age, and by more liberal use of free root replacement with re-implantation of the coronary arteries rather than tailoring the root to accommodate a subcoronary implantation.
Collapse
Affiliation(s)
- O Lund
- Academic Department of Cardiac Surgery, Harefield Hospital, Middlesex, United Kingdom
| | | | | | | | | | | | | | | | | |
Collapse
|
114
|
Abstract
BACKGROUND The 5-year follow-up of CryoLife-O'Brien stentless porcine aortic valve xenografts is presented. METHODS From August 1991 to August 1996, the valve was used in 366 patients. Patients' ages ranged from 18 to 90 years (mean, 73+/-6 years). Survivors were monitored with Doppler echocardiography before discharge, at 6 months, and then annually by the referring cardiologist. Operative and long-term mortality and morbidity were collected using the Edmunds guidelines for reporting morbidity and mortality after cardiac valvular operations. RESULTS The study was completed during a 6-month period with a 96.5% follow-up, comprising 999 patient-years for a mean follow-up period of 27 months (range, 3 to 64 months). Operative mortality was 6.5%. Linearized rates per patient-year for complications were as follows: structural valve deterioration (0%); thromboembolism (0.5%); prosthetic valve endocarditis (0.2%); valve reoperation (0.8%); and valve-related mortality (0.2%). Sixteen late deaths have occurred. The actuarial survival rate at 5 years was 83%+/-3.5%. CONCLUSIONS The Cryolife-O'Brien stentless valve has given excellent early hemodynamic and 5-year results.
Collapse
Affiliation(s)
- U Hvass
- Department of Cardiovascular Surgery, Hôpital Bichat, Paris, France
| | | |
Collapse
|
115
|
Dumesnil JG, LeBlanc MH, Cartier PC, Métras J, Desaulniers D, Doyle DP, Lemieux MD, Raymond G. Hemodynamic features of the freestyle aortic bioprosthesis compared with stented bioprosthesis. Ann Thorac Surg 1998; 66:S130-3. [PMID: 9930433 DOI: 10.1016/s0003-4975(98)01119-9] [Citation(s) in RCA: 47] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
BACKGROUND The Freestyle prosthesis is a new stentless aortic bioprosthesis. Anticipated benefits are improved hemodynamics and increased longevity. METHODS Doppler echocardiograms were performed early and at 3 to 6 months, 1 year, and 2 years after operation in 157 patients (69 men, 88 women, aged 48 to 85 years) with this prosthesis, and results were compared with hemodynamic data in patients with Intact and Mosaic stented bioprostheses. RESULTS Distinctive features of the prosthesis compared with stented prostheses are (1) an increase in effective orifice area (+0.15+/-0.26 cm2; p < 0.05) and a decrease in mean gradient (-3.5+/-4.0 mm Hg; p < 0.001) during the first 3 to 6 months postoperatively and stabilization thereafter; (2) a markedly lower mean gradient at 1 year after operation (average, 6+/-4 mm Hg) than in stented prostheses (Intact, 22+/-8 mm Hg; Mosaic, 12+/-6 mm Hg); (3) in contrast to stented prostheses, in vivo effective orifice areas much lower (-0.91+/-0.35 cm2) than those calculated in vitro; (4) as in stented prostheses, the indexed effective orifice area (cm2/m2) is the best predictor (r = 0.77 at 1 year) of the mean gradient after operation; and (5) similar incidence of aortic regurgitation (trivial or mild, 34% versus 29% in Intact). CONCLUSIONS The hemodynamics of the Freestyle are very satisfactory and represent a marked improvement in comparison to stented prosthesis.
Collapse
Affiliation(s)
- J G Dumesnil
- Quebec Heart Institute, Laval Hospital, Ste-Foy, Canada
| | | | | | | | | | | | | | | |
Collapse
|
116
|
Bach DS, David T, Yacoub M, Pepper J, Goldman B, Wood J, Verrier E, Petracek M, Aldrete V, Rosenbloom M, Azar H, Rakowski H. Hemodynamics and left ventricular mass regression following implantation of the Toronto SPV stentless porcine valve. Am J Cardiol 1998; 82:1214-9. [PMID: 9832097 DOI: 10.1016/s0002-9149(98)00607-9] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Stentless tissue valves may provide more favorable hemodynamics than conventional stented valves. Hemodynamic findings from a large multicenter trial have not been previously reported. The present report describes the hemodynamic findings from a multinational, multicenter study after implantation of the Toronto SPV valve. A total of 577 patients underwent aortic valve replacement with the Toronto SPV valve at 12 sites in 3 countries. Echocardiograms were recorded in the early postoperative period, 3 to 6 months after surgery, 1 year after surgery, and yearly thereafter, with follow-up to 3 years. Gradients decreased and effective orifice area increased in the months after surgery. One year after surgery, mean gradient for valve sizes 20 to 22, 23, 25, 27, and 29 mm was 7.3 +/- 4.4, 7.4 +/- 4.5, 6.1 +/- 3.3, 4.9 +/- 2.4, and 4.0 +/- 2.1 mm Hg, respectively; effective orifice area was 1.3 +/- 0.7, 1.5 +/- 0.5, 1.7 +/- 0.4, 2.0 +/- 0.4, and 2.4 +/- 0.6 cm2, respectively. There was a very low prevalence of significant aortic regurgitation at all time periods. There was significant left ventricular (LV) mass regression between the early and 3- to 6-month periods and between the 3- to 6-month and 1-year postoperative periods. The Toronto SPV valve has an excellent hemodynamic profile supported by significant regression of LV hypertrophy in the year after implantation. Data through 3 years demonstrates maintenance of low gradients and freedom from significant aortic regurgitation.
Collapse
Affiliation(s)
- D S Bach
- Department of Internal Medicine, University of Michigan, Ann Arbor 48109, USA.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
117
|
Tsukamoto M, Inoue S, Ito T, Hachiro Y, Muraki S, Abe T. Functional evaluation of the bileaflet mechanical valve in the aortic position using dobutamine-stress echocardiography: is a 23-mm prosthetic valve adequately large enough? JAPANESE CIRCULATION JOURNAL 1998; 62:817-23. [PMID: 9856597 DOI: 10.1253/jcj.62.817] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The issue of valve prosthesis-patient mismatch in small annular patients is still controversial. The hemodynamic function of bileaflet mechanical valves in the aortic position was examined using dobutamine-stress echocardiography. Forty-four patients were enrolled in the study and divided into 5 groups, according to prosthesis size, from 21 mm to 29 mm. The aortic peak pressure gradient (APG) increased significantly in all groups with dobutamine-stress and exceeded 50 mmHg in 83% of the 21-mm group, in 64% of the 23-mm group, and in 33% of the 25-mm group. The APG even exceeded 80 mmHg in 22% and 18% of the 21-mm and 23-mm groups, respectively. In these cases, the potential of 'valve prosthesis-patient mismatch' was considered. From the relationship between the APG and the prosthesis valve area index (VAI), 'critical VAIs' were found where patients were likely to enter the 'mismatch' status; that is, 1.22 and 1.77 cm2/m2, respectively, for the 5 and 10 microg/kg per min stages of dobutamine stress. This critical VAI range is useful in predicting the 'mismatch' patients preoperatively. Alternative procedures or prostheses should then be selected for them.
Collapse
Affiliation(s)
- M Tsukamoto
- Department of Thoracic and Cardiovascular Surgery, Sapporo Medical University, Japan
| | | | | | | | | | | |
Collapse
|
118
|
De Paulis R, Sommariva L, Colagrande L, De Matteis GM, Fratini S, Tomai F, Bassano C, Penta de Peppo A, Chiariello L. Regression of left ventricular hypertrophy after aortic valve replacement for aortic stenosis with different valve substitutes. J Thorac Cardiovasc Surg 1998; 116:590-8. [PMID: 9766587 DOI: 10.1016/s0022-5223(98)70165-5] [Citation(s) in RCA: 52] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
OBJECTIVE Stentless biologic aortic valves are less obstructive than stented biologic or mechanical valves. Their superior hemodynamic performances are expected to reflect in better regression of left ventricular hypertrophy. We compared the regression of left ventricular hypertrophy in 3 groups of patients undergoing aortic valve replacement for severe aortic stenosis. Group I (10 patients) received stentless biologic aortic valves, group II (10 patients) received stented biologic aortic valves, and group III (10 patients) received bileaflet mechanical aortic valves. METHODS Echocardiographic evaluations were performed before the operation and after 1 year, and the results were compared with those of a control group. Left ventricular diameters and function, left ventricular wall thickness, and left ventricular mass were assessed by echocardiography. RESULTS Group I patients had a significantly lower maximum and mean transprosthetic gradient than the other valve groups (P = .001). One year after operation there was a significant reduction in left ventricular mass for all patient groups (P < .01), but mass did not reach normal values (P = .05). Although the rate of regression in the interventricular septum and posterior wall thickness differed slightly among groups, their values at follow-up were comparable and still higher than control values (P = .002). The ratio between interventricular septum and posterior wall and the ratio between wall thickness and chamber radius did not change significantly at follow-up. CONCLUSIONS Because the number of patients was relatively small, we could not use left ventricular mass regression after I year to distinguish among patients undergoing aortic valve replacement for aortic stenosis by means of valve prostheses with different hemodynamic performances.
Collapse
Affiliation(s)
- R De Paulis
- Cardiac Surgery Department, Tor Vergata University of Rome, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|
119
|
Hunziker PR, Spöndlin B, Hediger S, Burckhardt D, Brett W, Buser P. Long-Term Follow-Up and Dobutamine Stress Echocardiography of 19-mm Prosthetic Heart Valves. Echocardiography 1998; 15:617-624. [PMID: 11175091 DOI: 10.1111/j.1540-8175.1998.tb00659.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND: In patients with a small aortic root, the use of 19-mm valve prostheses for valve replacement is controversial because of the small orifice area of these valves. METHODS: To assess stress hemodynamics in patients with 19-mm valve prostheses, to find predictors of unfavorable hemodynamics, and to document the long-term follow-up, we examined 30 patients (age, 64 +/- 19 years; 27 women and 3 men; follow-up, 38 +/- 50 months) clinically and with the use of dobutamine stress echocardiography. A history was taken, and a physical examination was performed. At rest and during dobutamine stress, Doppler echocardiography was performed. RESULTS: At rest, transprosthetic gradients were moderately elevated with mean and peak gradients of 15 +/- 7 and 32 +/- 14 mmHg, and effective orifice areas were small (0.91 +/- 0.31 cm(2)). Gradients rose markedly during stress (mean, 37 +/- 14 mmHg; peak, 83 +/- 41 mmHg). Predictors of high transprosthetic gradients were larger body surface area, younger age, and valve type. Mean and peak gradients were lower with St. Jude Medical Hemodynamic Plus valves than with standard St. Jude Medical (P < 0.05) and other valves, and the effective orifice area was highest (1.07 +/- 0.29 cm(2); P < 0.05 versus standard St. Jude Medical) in this valve model. Sixty percent of patients developed significant dynamic subvalvular or intraventricular gradients (84 +/- 41 mmHg) during dobutamine stress. CONCLUSIONS: After aortic valve replacement with 19-mm prostheses in patients with a small aortic root, dobutamine stress leads to high transvalvular gradients, which are dependent on valve model, age, and body surface area. In addition, 60% of patients develop significant dynamic outflow obstructions. These findings and the persistence of some degree of exercise-induced symptoms in 70% of patients suggest that alternative surgical techniques should be considered if the size of the aortic annulus demands a 19-mm valve, especially if the patient seeks physical activity, is young, or is of larger body size.
Collapse
Affiliation(s)
- Patrick R. Hunziker
- Division of Cardiology, University Hospital, Petergraben 5, 4031 Basel, Switzerland
| | | | | | | | | | | |
Collapse
|
120
|
Jin XY, Dhital K, Bhattacharya K, Pieris R, Amarasena N, Pillai R. Fifth-year hemodynamic performance of the prima stentless aortic valve. Ann Thorac Surg 1998; 66:805-9. [PMID: 9768934 DOI: 10.1016/s0003-4975(98)00550-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
BACKGROUND The medium-term hemodynamic performance of stentless valves has not been widely reported, particularly in comparison with in vitro studies. Therefore, we have assessed prospectively the hemodynamics of the Edwards Prima valve in its fifth year after implantation in the aortic position, and compared the results with those at 1 month after implantation and also with in vitro data. METHODS Thirty-five patients (age, 77 +/- 6 years; 19 men) were prospectively studied by Doppler echocardiography at 1 month and 52 +/- 8 months after implantation of a Prima stentless valve. Valve hemodynamics were assessed by measuring the mean pressure gradient, mean valve resistance, and effective orifice area. Left ventricular systolic function was quantified by ejection fraction, the degree of hypertrophy by ventricular mass index, and the ratio of ventricular wall thickness to cavity radius as a measure of ventricular geometry. RESULTS With a mean valve size of 24.6 +/- 2.2 mm in the fifth year after implantation, the mean pressure gradient was 6.2 +/- 3.5 mm Hg, the mean valve resistance, 29 +/- 16 dyne x s(-1) x cm(-5)), and the effective orifice area was 2.05 +/- 0.50 cm2. Compared with 1 month after operation, there was a 47% decrease in mean valve resistance (p = 0.002) and a 39% increase in effective orifice area (p = 0.001). Furthermore, both effective orifice area and mean valve resistance in the fifth year did not differ from their in vitro counterparts, whereas the left ventricular ejection fraction (0.64 +/- 0.14), the left ventricular mass index (119 +/- 49 g/m2), and the ratio of ventricular wall thickness to cavity radius (0.44 +/- 0.13) were within the normal range. CONCLUSIONS This study suggests that the Prima valve is a reliable stentless aortic bioprosthesis. This is supported by a favorable medium-term clinical outcome, durable hemodynamic performance, and normal mean values of left ventricular ejection fraction and mass index in the fifth year after implantation.
Collapse
Affiliation(s)
- X Y Jin
- Department of Cardiac Surgery, Oxford Heart Centre, John Radcliffe Hospital, England
| | | | | | | | | | | |
Collapse
|
121
|
Abstract
The implantation of stentless porcine valves (SPVs) is technically more demanding than implantation of stented bioprosthetic valves. Implantation of the Toronto SPV bioprosthesis requires an,understanding of the relationships between the leaflets and the aortic annulus and sinotubular junction. In addition to proper alignment of the three commissures within the aortic root, the diameter of sinotubular junction should not exceed the external diameter of the porcine aortic valve after completion of the operation. The Medtronic Freestyle porcine aortic root bioprosthesis can be used for subcoronary implantation as well as for aortic root replacement. Degenerative calcification of a tricuspid aortic valve is the most common cause of aortic valve disease in older patients. Implantation of stentless valves in the subcoronary position is usually feasible because the geometry of the aortic root is well maintained in these patients. The bicuspid aortic valve is the second most common cause of aortic valve disease in older patients and the most common in younger patients. These patients frequently have dilated aortic root, and the Medtronic Freestyle bioprosthesis is ideal for implantation using the root inclusion technique. Stentless porcine bioprostheses are minimally obstructive and associated with low mean systolic gradients. In addition, they have better hemodynamic performance during exercise than stented bioprostheses. For these reasons, patient-prosthesis mismatch has not been described with stentless valves. Left ventricular function after aortic valve replacement appears to be better with stentless than with stented bioprostheses. Comparative, nonrandomized studies of aortic valve replacement with stented and stentless valves suggest that the risk of cardiac death is reduced with stentless valves and the rates of valve-related complications also appear to be lower. What remains unknown is whether stentless valves are more durable than stented ones.
Collapse
Affiliation(s)
- T E David
- Division of Cardiovascular Surgery of The Toronto Hospital and University of Toronto, Ontario, Canada
| |
Collapse
|
122
|
Legare JF, Wood JW, Koilpillai C, Buth KJ, MacDougall C, Ross DB. St. Jude SPV versus Medtronic Freestyle: a single institution comparison of two stentless aortic valves. J Card Surg 1998; 13:392-7. [PMID: 10440655 DOI: 10.1111/j.1540-8191.1998.tb01102.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND Improved hemodynamics with the SPV and Freestyle bioprostheses compared to stented valves have been reported. It has been suggested that there is more aortic insufficiency (Al) with the Freestyle than with the SPV valve. This study was designed to assess the hemodynamic performance of these two valves implanted at a single institution with all echocardiograms reviewed by one echocardiographer. METHODS From 1993 to 1997 112 patients underwent aortic valve replacement with stentless aortic valves (69 SPV, 43 Freestyle). There were no major preoperative differences in patient age, gender, NYHA class, or ejection fraction between groups. Echocardiographic assessment was obtained at discharge, 3 to 6 months following surgery, and yearly thereafter. RESULTS Mean follow-up was 15.9 months for the SPV and 28.6 months for the Freestyle. Both valves have excellent valve areas and low transvalvar mean gradients. There is a trend for more Al in the SPV group. At 1 year, 1+ or greater Al was present in 11 of 42 SPV patients compared to 2 of 34 Freestyle patients (p = 0.030). Al has tended to remain stable over time, has not progressed, and is not clinically evident. DISCUSSION Differences in the previously reported incidence of aortic insufficiency with these valves may have more to do with the method of reporting Al than its actual frequency. Within our institution, there has been slightly more mild Al with the SPV valve than with Freestyle. Long-term follow-up of these valves is needed to determine if the Al progresses or becomes clinically important. To date there is no such trend with either valve.
Collapse
Affiliation(s)
- J F Legare
- QEII Health Sciences Centre, New Halifax Infirmary, Nova Scotia, Canada
| | | | | | | | | | | |
Collapse
|
123
|
Westaby S, Jin XY, Katsumata T, Arifi A, Braidley P. Valve replacement with a stentless bioprosthesis: versatility of the porcine aortic root. J Thorac Cardiovasc Surg 1998; 116:477-84. [PMID: 9731790 DOI: 10.1016/s0022-5223(98)70014-5] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE Stentless valves convey important hemodynamic benefits but are used selectively depending on aortic root structure. The Freestyle valve (Medtronic, Inc, Minneapolis, Minn) is a versatile device that can be implanted by different methods depending on operating conditions. We aimed to demonstrate that a stentless valve could be used in every patient without increased risk of morbidity or mortality. We documented the effects of this valve on clinical outcome and left ventricular mechanics. METHODS The Freestyle valve was implanted by the modified subcoronary method into 200 consecutive unselected patients who received a tissue valve in the aortic position and by root replacement in 2. Forty-three percent were older than 75 years. Forty percent underwent coronary bypass. Detailed clinical and echocardiographic follow-up (Food and Drug Administration protocol) was used out to 3 years. RESULTS Mean ischemic time was 43+/-6 minutes for isolated aortic valve replacement and 63+/-14 minutes with concomitant procedures. Thirty-day mortality was 6%, none of the deaths being valve related. Hemodynamic function improved progressively with falling valve gradients and increased effective orifice areas. Left ventricular mass fell within normal limits over 2 years, but at 3 years there was a non-valve-related upswing. No instances of valve thrombosis, hemolysis, or paravalvular leak were noted. Less than 5% had mild to moderate aortic regurgitation. CONCLUSIONS The Freestyle valve can be used in virtually every patient with aortic valve disease and provides superlative hemodynamic outcome. Hospital mortality and morbidity are similar to those reported for stented valves in an elderly population.
Collapse
Affiliation(s)
- S Westaby
- Department of Cardiac Surgery, Oxford Heart Centre, The John Radcliffe Hospital, United Kingdom
| | | | | | | | | |
Collapse
|
124
|
Del Rizzo DF, Abdoh A. Clinical and hemodynamic comparison of the Medtronic Freestyle and Toronto SPV stentless valves. J Card Surg 1998; 13:398-407. [PMID: 10440656 DOI: 10.1111/j.1540-8191.1998.tb01103.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The excellent hemodynamics of stentless valves have been observed by numerous investigators. With the recent release of the Toronto SPV (stentless porcine valve) and the Medtronic Freestyle stentless valves in North America, it is appropriate to now compare the clinical and hemodynamic performance of these devices. We analyzed the results of 995 patients who underwent aortic valve replacement (AVR) with either of the two valves; in all cases a subcoronary implant technique was used. There were important differences in the preoperative characteristics for the two groups: Medtronic Freestyle patients were notably older than the Toronto SPV patients (70.7+/-8.6 vs 61.8+/-11.1 years, p < 0.001) and were markedly more symptomatic (p < 0.0001). In the Toronto SPV group, most patients had New York Heart Association (NYHA) Class II (41.5%) or Class III (44.7%) symptoms preoperatively, while in the Freestyle group, 61.5% were in Class III and 12.5% were in Class IV. There were no notable differences in mortality or morbidity for the two groups. Both devices demonstrated a meaningful decrease in mean gradient and a corresponding increase in effective orifice area (EOA). Furthermore, the indexed EOA (EOA/body surface area [BSA]) was > 1cm2/m2 for all valves indicating there was no patient-prosthetic mismatch. There was a meaningful decrease in left ventricular (LV) mass as well as LV mass index (LVMI) for both devices up to 3 years postoperatively. Our data indicate that there were no differences in clinical outcome or hemodynamic performance of these two valves. Both devices offer excellent results with normalization of LV function.
Collapse
Affiliation(s)
- D F Del Rizzo
- Department of Surgery, University of Manitoba, Winnipeg, Canada.
| | | |
Collapse
|
125
|
Pepper JR, Chir M. The stentless porcine valve. J Card Surg 1998; 13:352-9. [PMID: 10440650 DOI: 10.1111/j.1540-8191.1998.tb01097.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Recognition of the long-term results of homografts has brought about a renewed interest in stentless valves. This has been matched by the introduction of several glutaraldehyde preserved porcine stentless prostheses. The early experience indicates that these valves are technically somewhat simpler to insert than homografts and are associated with satisfactory early and immediate-term results. In particular, they appear to offer an earlier and more complete resolution of left ventricular hypertrophy. Correct insertion of a stentless porcine valve needs meticulous attention to detail and awareness of the precise anatomical features of the aortic root, which is a complex structure. Although the myocardial ischemic and cardiopulmonary bypass times are longer for the more complex insertion of this prosthesis, our studies indicate that this has no serious disadvantage to the patient and is more than matched by an improved hemodynamic performance associated with more stable left ventricular function. The theoretical advantages of a stentless valve substitute in the aortic position seem clear. Further detailed prospective studies are needed to report on the long-term performance of this valve.
Collapse
Affiliation(s)
- J R Pepper
- The Department of Surgery, Royal Brompton and Harefield Hospitals NHS Trust, London, United Kingdom
| | | |
Collapse
|
126
|
David TE, Puschmann R, Ivanov J, Bos J, Armstrong S, Feindel CM, Scully HE. Aortic valve replacement with stentless and stented porcine valves: a case-match study. J Thorac Cardiovasc Surg 1998; 116:236-41. [PMID: 9699575 DOI: 10.1016/s0022-5223(98)70122-9] [Citation(s) in RCA: 102] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
OBJECTIVES To assess the potential benefits of the hemodynamic superiority of stentless valves, we conducted a case-match study among patients who underwent aortic valve replacement with two types of porcine bioprostheses: the Toronto SPV and the stented Hancock II bioprosthesis. METHODS Preoperative clinical variables predictive of death after aortic valve replacement were determined by a stepwise logistic regression analysis in a series of 908 consecutive patients who received porcine aortic bioprostheses during a 14-year interval. Advanced age, New York Heart Association functional class IV, left ventricular ejection fraction of less than 30%, and coronary artery disease were independent predictors of death. On the basis of these four variables, 198 pairs of patients who survived aortic valve replacement with stentless and stented porcine valves were matched. The follow-up, truncated to the shortest interval for each matched pair, was 43 +/- 24 months for both groups. RESULTS At 8 years the actuarial survival was 91% +/- 4% for the Toronto SPV group and 69% +/- 8% for the Hancock II group (p = 0.006); the freedom from cardiac-related death was 95% +/- 4% for the Toronto SPV and 81% +/- 8% for the Hancock II (p = 0.01); the freedom from any valve-related complication was 81% +/- 5% for the Toronto SPV and 50% +/- 10% for the Hancock II (p = 0.008). A Cox proportional hazard model demonstrated a significant reduction in cardiac mortality rates and valve-related morbidity in patients who received the Toronto SPV bioprosthesis. CONCLUSIONS Although it is possible that confounding factors may have played a role in the clinical outcomes of this case-control study, the study suggests that aortic valve replacement with a stentless porcine valve enhances survival. This is believed to be due to the hemodynamic superiority of these valves.
Collapse
Affiliation(s)
- T E David
- Division of Cardiovascular Surgery of The Toronto Hospital and the University of Toronto, Ontario, Canada
| | | | | | | | | | | | | |
Collapse
|
127
|
Bertolini P, Luciani GB, Vecchi B, Pugliese P, Mazzucco A. Aortic valve replacement with the Biocor PSB stentless xenograft. Ann Thorac Surg 1998; 66:425-30. [PMID: 9725379 DOI: 10.1016/s0003-4975(98)00345-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
BACKGROUND The midterm clinical results after aortic valve replacement with the Biocor PSB stentless xenograft on all patients operated between October 1992 and October 1996 were reviewed. METHODS One hundred six patients, aged 70+/-6 years, had aortic valve replacement for aortic stenosis (67%), regurgitation (11%), or both (22%). Associated procedures were done in 49 patients (46%), including coronary artery bypass in 30 patients, mitral valve repair/replacement in 16, and ascending aorta replacement in 5 patients. Aortic cross-clamp and cardiopulmonary bypass times were 96+/-24 and 129+/-31 minutes, respectively. RESULTS There were 3 (3%) early deaths due to low output (2 patients) and cerebrovascular accident (1 patient). Follow-up of survivors ranged from 6 to 66 months (mean, 39+/-14 months). Survival was 94%+/-2% and 90%+/-3% at 1 and 5 years. There were 5 late deaths due to cardiac cause (2), cancer (2), and pulmonary embolism (1 patient). No patient had structural valve deterioration, whereas 100% and 95%+/-3% were free from valve-related events at 1 and 5 years. There were two reoperations due to narrowing of the left coronary ostium and endocarditis, with an actuarial freedom from reoperation of 99%+/-1% and 98+/-1% at 1 and 5 years, respectively. Functional results demonstrated a mean peak transprosthetic gradient of 16+/-12 mm Hg, with only 1 patient (1%) with a 55 mm Hg gradient. No cases of valve regurgitation greater than mild were recorded at follow-up. Assessment of New York Heart Association functional class demonstrated a significant improvement (2.9+/-0.6 versus 1.4+/-0.7; p=0.01). All patients were free from anticoagulation. CONCLUSIONS Aortic valve replacement using the Biocor PSB stentless xenograft offers excellent midterm survival, negligible valve deterioration, and a very low rate of valve-related events, which are comparable to estimates reported with other models of stentless xenografts and currently available stented xenografts. Hemodynamic performance is favorable and quality of life satisfactory.
Collapse
Affiliation(s)
- P Bertolini
- Division of Cardiac Surgery, University of Verona, Italy
| | | | | | | | | |
Collapse
|
128
|
Doty JR, Flores JH, Millar RC, Doty DB. Aortic valve replacement with medtronic freestyle bioprosthesis: operative technique and results. J Card Surg 1998; 13:208-17. [PMID: 10193992 DOI: 10.1111/j.1540-8191.1998.tb01264.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE This study evaluates the initial results for safety and efficacy of aortic valve replacement (AVR) using the Medtronic Freestyle Bioprosthesis. METHODS One hundred three patients underwent AVR with the Medtronic Freestyle Bioprosthesis over a 40-month period. There were 59 male and 44 female patients with a mean age of 74 years (range 36 to 88 years). Valve size ranged from 19 to 27 mm, and all valves were implanted using a freehand subcoronary technique. Anticoagulation with coumadin was only used for atrial fibrillation. Aspirin was given to patients with associated coronary artery disease. Echocardiography to assess transvalvular pressure gradient and effective valve orifice area was performed at discharge, 3 to 6 months, 1 year, and then annually. RESULTS There were 4 (3.9%) deaths within 30 days of operation and 5 (4.9%) late deaths. Two (1.9%) deaths were valve-related, one from commissural dehiscence and one from bacterial endocarditis. Three (2.9%) deaths, two early and one late, were from other cardiac causes. The remaining deaths were from noncardiac causes. Five (4.9%) patients suffered a thromboembolic event, two had permanent neurological deficits, two had transient neurological events, and one had coronary artery occlusion. Mean transvalvular gradient assessed by echocardiography was low at all time intervals: discharge (12.8 mmHg), 3 to 6 months (11.3 mmHg), 1 year (12.0 mmHg), and 2 years (11.6 mmHg). Mean effective valve orifice area was good at all time intervals: discharge (1.4 cm2), 3 to 6 months (1.5 cm2), 1 year (1.6 cm2), and 2 years (1.6 cm2). Of the 38 patients assessed by echocardiography at 1 year, 33 (87%) had no or trivial valve incompetence and the remainder had mild valve incompetence. CONCLUSIONS Aortic valve replacement with the Medtronic Freestyle Bioprosthesis has a low incidence of early valve-related mortality and thromboembolism. The bioprosthesis demonstrates good hemodynamic performance even in small diameters and is particularly well suited for older patients and the small aortic root.
Collapse
Affiliation(s)
- J R Doty
- The Department of Surgery, LDS Hospital, Salt Lake City, Utah 84103, USA.
| | | | | | | |
Collapse
|
129
|
Westaby S, Huysmans HA, David TE. Stentless aortic bioprostheses: compelling data from the Second International Symposium. Ann Thorac Surg 1998; 65:235-40. [PMID: 9456124 DOI: 10.1016/s0003-4975(97)01290-3] [Citation(s) in RCA: 51] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
BACKGROUND Stentless aortic xenografts are an important addition to the range of prosthetic valves. So far their use has been restricted to a limited number of study centers. This report summarizes the principal findings from the Second International Symposium on Stentless Bioprostheses. Attention is focused on the Toronto SPV and Freestyle valves recently approved by the United States Food and Drug Administration. METHODS Stentless xenografts are used predominantly in elderly patients with aortic stenosis. Implant techniques are more complex than for stented valves, as reflected by longer ischemic and cardiopulmonary bypass times. The valves have been subjected to detailed serial echocardiographic assessment and clinical follow-up. RESULTS The hemodynamic characteristics resemble those of the aortic homograft. There is a progressive increase in effective orifice area and decrease in transvalvular pressure gradients with time. Left ventricular mass index and wall thickness normalize between 6 and 12 months postoperatively. Left ventricular remodeling is accompanied by improved symptomatic status and a low incidence of valve-related complications. Limited comparative studies suggest important benefits over stented xenografts. Improved hemodynamics may translate into better bioprosthetic durability. CONCLUSIONS Reproducible and reliable implant methods should be taught carefully, but the hemodynamic advantages are substantial. Stentless xenografts are ideal for the elderly patient with aortic stenosis.
Collapse
Affiliation(s)
- S Westaby
- Oxford Heart Centre, John Radcliffe Hospital, United Kingdom
| | | | | |
Collapse
|
130
|
Abstract
In the presence of severe dilatation of the ascending aorta the implantation of a Toronto SPV stentless bioprosthesis is compromised by the risk of postoperative central regurgitation. A modification of the implantation technique is described that restores the normal shape of the ascending aorta and thereby avoids the risk of dysfunction of the prosthesis.
Collapse
Affiliation(s)
- R P Siebenmann
- Cardiovascular Surgery, HerzZentrum Hirslanden, Zürich, Switzerland
| |
Collapse
|
131
|
Del Rizzo DF, Goldman BS, Christakis GT, David TE. Hemodynamic benefits of the Toronto Stentless Valve. J Thorac Cardiovasc Surg 1996; 112:1431-45; discussion 1445-6. [PMID: 8975834 DOI: 10.1016/s0022-5223(96)70001-6] [Citation(s) in RCA: 82] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
We report on 254 consecutive patients (170 male, 84 female) undergoing aortic valve replacement with the Toronto SPV Stentless Valve (St. Jude Medical, Inc., St. Paul, Minn.). Mean age (+/- standard deviation) was 62.1 +/- 11.6 years. Three patients (1%) received sizes 21 or 22 mm, 24 (9%) received size 23 mm, and 227 patients (89%) received sizes 25, 27, or 29 mm. Serial echocardiography was used to assess valve performance during a 3-year follow-up. Mean gradient decreased by 35.8% (p < 0.0001; 95% confidence interval -39.6%, -31.7%) from postoperative values to the 3- to 6-month follow-up and by 6.1% (p = 0.004; 95% confidence interval -10.1%, -2%) at each subsequent interval; effective orifice area increased by 17.2% (p = 0.0001; 95% confidence interval 12.0%, 22.6%) initially and by 4.4% (p < 0.001; 95% confidence interval 1.8%, 7.0%) thereafter. At 2 years of follow-up, mean gradient was 3.3 +/- 2.1 mm Hg and mean effective orifice area was 2.2 +/- 0.8 cm2. Studies on left ventricular mass were carried out on 84 patients. Left ventricular mass decreased by 14.3% (37.8 +/- 57.9 gm; p < 0.0001; 95% confidence interval -53.7, -21.9 gm) and left ventricular mass index decreased by 15.2% (21.1 +/- 30.5 gm/m2; p < 0.0001; 95% confidence interval -29.5, -12.7 gm/m2) from postoperative values to the 3- to 6-month follow-up interval. The reduction in residual gradient and potential regression in left ventricular hypertrophy may have a beneficial prognostic implication. We believe that the unique stentless design of the Toronto SPV Stentless Valve allows this to occur.
Collapse
Affiliation(s)
- D F Del Rizzo
- Sunnybrook Health Science Centre, University of Toronto, Canada
| | | | | | | |
Collapse
|