101
|
Li P, He Q, Liu H, Liu Y, Su J, Tian N, Zhan D. Collision Incidents of Single Tetrahexahedral Platinum Nanocrystals Recorded by a Carbon Nanoelectrode. ChemElectroChem 2018. [DOI: 10.1002/celc.201800650] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Pei Li
- State Key Laboratory of Physical Chemistry of Solid Surfaces Collaborative Innovation Centre of Chemistry for Energy Materials College of Chemistry and Chemical EngineeringXiamen University Xiamen 361005 China
| | - Quanfeng He
- State Key Laboratory of Physical Chemistry of Solid Surfaces Collaborative Innovation Centre of Chemistry for Energy Materials College of Chemistry and Chemical EngineeringXiamen University Xiamen 361005 China
| | - Hai‐Xia Liu
- State Key Laboratory of Physical Chemistry of Solid Surfaces Collaborative Innovation Centre of Chemistry for Energy Materials College of Chemistry and Chemical EngineeringXiamen University Xiamen 361005 China
- Key Laboratory of Mesoscopic Chemistry of MOE Collaborative Innovation Center of Chemistry for Life Sciences School of Chemistry and Chemical EngineeringNanjing University Nanjing 210093 China
| | - Yunhua Liu
- National CAD Support Software Engineering Research CenterHuazhong University of Science and Technology Wuhan 430074 China
| | - Jian‐Jia Su
- State Key Laboratory of Physical Chemistry of Solid Surfaces Collaborative Innovation Centre of Chemistry for Energy Materials College of Chemistry and Chemical EngineeringXiamen University Xiamen 361005 China
| | - Na Tian
- State Key Laboratory of Physical Chemistry of Solid Surfaces Collaborative Innovation Centre of Chemistry for Energy Materials College of Chemistry and Chemical EngineeringXiamen University Xiamen 361005 China
| | - Dongping Zhan
- State Key Laboratory of Physical Chemistry of Solid Surfaces Collaborative Innovation Centre of Chemistry for Energy Materials College of Chemistry and Chemical EngineeringXiamen University Xiamen 361005 China
| |
Collapse
|
102
|
Xu M, Pan R, Zhu Y, Jiang D, Chen HY. Resistive Analysis of Hydrogen Peroxide in One Axon of Single Neuron with Nanopipets. Anal Chem 2018; 90:10117-10121. [DOI: 10.1021/acs.analchem.8b01539] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Mingchen Xu
- The State Key Lab of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, Jiangsu 210093, China
| | - Rongrong Pan
- The State Key Lab of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, Jiangsu 210093, China
| | - Yue Zhu
- Jiangsu Key Laboratory for High Technology Research of TCM Formulae and Jiangsu Collaborative Innovation Center of Chinese Medicinal Resources Industrialization, Nanjing University of Chinese Medicine, Nanjing, Jiangsu 210093, China
| | - Dechen Jiang
- The State Key Lab of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, Jiangsu 210093, China
| | - Hong-Yuan Chen
- The State Key Lab of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, Jiangsu 210093, China
| |
Collapse
|
103
|
Zhang H, Ruan J, Liu W, Jiang X, Du T, Jiang H, Alberto P, Gottschalk KE, Wang X. Monitoring dynamic release of intracellular hydrogen peroxide through a microelectrode based enzymatic biosensor. Anal Bioanal Chem 2018; 410:4509-4517. [PMID: 29796900 DOI: 10.1007/s00216-018-1108-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Revised: 03/25/2018] [Accepted: 04/24/2018] [Indexed: 01/01/2023]
Abstract
A high sensitive and selective hydrogen peroxide (H2O2) biosensor was fabricated on the basis of reduced hemoglobin (Hb) and single-walled carbon nanotubes (SWCNTs) for detecting the release of H2O2 from living HepG2 cancer cells in the process of the in situ biosynthesis of ZnO quantum. The modification of carbon fiber microelectrode (CFME) was carried out by physical adsorption. By the scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS), the dense cover of surface and successful immobilization were characterized. Electrochemical investigation demonstrates that the as-prepared modified microelectrode showed a quasi-reversible process toward the reduction of H2O2, which exhibited a linear range from 0.51 to 10.6 μM, with a limit of detection of 0.23 μM. This microelectrode biosensor was applied for the quantification of the change of H2O2 concentration released from HepG2 cells through the in situ biosynthesis of ZnO quantum dots, which was further confirmed by the fluorescence staining.
Collapse
Affiliation(s)
- Hang Zhang
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Jun Ruan
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Weiwei Liu
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Xuerui Jiang
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Tianyu Du
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Hui Jiang
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Pasquarelli Alberto
- Institute of Experimental Physics, Ulm University, Albert Einstein Allee 45, 89069, Ulm, Germany
| | - Kay-Eberhard Gottschalk
- Institute of Experimental Physics, Ulm University, Albert Einstein Allee 45, 89069, Ulm, Germany
| | - Xuemei Wang
- State Key Laboratory of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.
| |
Collapse
|
104
|
Shi W, Zeng Y, Zhu C, Xiao Y, Cummins TR, Hou J, Baker LA. Characterization of Membrane Patch-Ion Channel Probes for Scanning Ion Conductance Microscopy. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2018; 14:e1702945. [PMID: 29226633 PMCID: PMC6955111 DOI: 10.1002/smll.201702945] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2017] [Revised: 10/09/2017] [Indexed: 05/07/2023]
Abstract
Integration of dual-barrel membrane patch-ion channel probes (MP-ICPs) to scanning ion conductance microscopy (SICM) holds promise of providing a revolutionized approach of spatially resolved chemical sensing. A series of experiments are performed to further the understanding of the system and to answer some fundamental questions, in preparation for future developments of this approach. First, MP-ICPs are constructed that contain different types of ion channels including transient receptor potential vanilloid 1 and large conductance Ca2+ -activated K+ channels to establish the generalizability of the methods. Next, the capability of the MP-ICP platforms in single ion channel activity measurements is proved. In addition, the interplay between the SICM barrel and the ICP barrel is studied. For ion channels gated by uncharged ligands, channel activity at the ICP barrel is unaffected by the SICM barrel potential; whereas for ion channels that are gated by charged ligands, enhanced channel activity can be obtained by biasing the SICM barrel at potentials with opposite polarity to the charge of the ligand molecules. Finally, a proof-of-principle experiment is performed and site-specific molecular/ionic flux sensing is demonstrated at single-ion-channel level, which show that the MP-ICP platform can be used to quantify local molecular/ionic concentrations.
Collapse
Affiliation(s)
- Wenqing Shi
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405
| | - Yuhan Zeng
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405
| | - Cheng Zhu
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405
| | - Yucheng Xiao
- Department of Biology, Indiana University-Purdue University Indianapolis, Stark Neurosciences Research Institute, 723 West Michigan Street, SL-306 Indianapolis, Indiana 46202
| | - Theodore R. Cummins
- Department of Biology, Indiana University-Purdue University Indianapolis, Stark Neurosciences Research Institute, 723 West Michigan Street, SL-306 Indianapolis, Indiana 46202
| | - Jianghui Hou
- Department of Internal Medicine – Renal Division, Division of Biological and Biochemical Sciences, Washington University School of Medicine, 660 South Euclid Avenue, Campus Box 8126, St. Louis, Missouri 63110
| | - Lane A. Baker
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405
- Author to whom correspondence should be addressed., ; Phone: (812) 856-1873; Fax: (812) 856-8300
| |
Collapse
|
105
|
Parizi KB, Akin D, Wong HSP. Internalization of subcellular-scale microfabricated chips by healthy and cancer cells. PLoS One 2018; 13:e0194712. [PMID: 29601607 PMCID: PMC5877870 DOI: 10.1371/journal.pone.0194712] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2017] [Accepted: 03/08/2018] [Indexed: 11/18/2022] Open
Abstract
Continuous monitoring of physiological parameters inside a living cell will lead to major advances in our understanding of biology and complex diseases, such as cancer. It also enables the development of new medical diagnostics and therapeutics. Progress in nanofabrication and wireless communication has opened up the potential of making a wireless chip small enough that it can be wholly inserted into a living cell. To investigate how such chips could be internalized into various types of living single cells and how this process might affect cells' physiology, we designed and fabricated a series of multilayered micron-scale tag structures with different sizes as potential RFID (Radio Frequency IDentification) cell trackers. While the present structures are test structures that do not resonate, the tags that do resonate have similar structure from device fabrication, material properties, and device size point of view. The structures are in four different sizes, the largest with the lateral dimension of 9 μm × 21 μm. The thickness for these structures is kept constant at 1.5 μm. We demonstrate successful delivery of our fabricated chips into various types of living cells, such as melanoma skin cancer, breast cancer, colon cancer and healthy/normal fibroblast skin cells. To our surprise, we observed a remarkable internalization rate difference between each cell type; the uptake rate was faster for more aggressive cancer cells than the normal/healthy cells. Cell viability before and after tag cellular internalization and persistence of the internalized tags have also been recorded over the course of five days of incubation. These results establish the foundations of the possibility of long term, wireless, intracellular physiological signal monitoring.
Collapse
Affiliation(s)
- Kokab B. Parizi
- Department of Electrical Engineering, School of Engineering, Stanford University, Stanford, California, United States of America
- * E-mail:
| | - Demir Akin
- Center for Cancer Nanotechnology Excellence, Department of Radiology, School of Medicine, Stanford University, Stanford, California, United States of America
| | - H.-S. Philip Wong
- Department of Electrical Engineering, School of Engineering, Stanford University, Stanford, California, United States of America
| |
Collapse
|
106
|
Zhang J, Zhou J, Pan R, Jiang D, Burgess JD, Chen HY. New Frontiers and Challenges for Single-Cell Electrochemical Analysis. ACS Sens 2018; 3:242-250. [PMID: 29276834 DOI: 10.1021/acssensors.7b00711] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Previous measurements of cell populations might obscure many important cellular differences, and new strategies for single-cell analyses are urgently needed to re-examine these fundamental biological principles for better diagnosis and treatment of diseases. Electrochemistry is a robust technique for the analysis of single living cells that has the advantages of minor interruption of cellular activity and provides the capability of high spatiotemporal resolution. The achievements of the past 30 years have revealed significant information about the exocytotic events of single cells to elucidate the mechanisms of cellular activity. Currently, the rapid developments of micro/nanofabrication and optoelectronic technologies drive the development of multifunctional electrodes and novel electrochemical approaches with higher resolution for single cells. In this Perspective, three new frontiers in this field, namely, electrochemical microscopy, intracellular analysis, and single-cell analysis in a biological system (i.e., neocortex and retina), are reviewed. The unique features and remaining challenges of these techniques are discussed.
Collapse
Affiliation(s)
- Jingjing Zhang
- The
State Key Laboratory of Analytical Chemistry for Life Science, School
of Chemistry and Chemical Engineering, Nanjing University, Jiangsu 210093, China
| | - Junyu Zhou
- The
State Key Laboratory of Analytical Chemistry for Life Science, School
of Chemistry and Chemical Engineering, Nanjing University, Jiangsu 210093, China
| | - Rongrong Pan
- The
State Key Laboratory of Analytical Chemistry for Life Science, School
of Chemistry and Chemical Engineering, Nanjing University, Jiangsu 210093, China
| | - Dechen Jiang
- The
State Key Laboratory of Analytical Chemistry for Life Science, School
of Chemistry and Chemical Engineering, Nanjing University, Jiangsu 210093, China
| | - James D. Burgess
- Department
of Medical Laboratory, Imaging, and Radiologic Sciences, College of
Allied Health Sciences, Augusta University, Augusta, Georgia 30912, United States
| | - Hong-Yuan Chen
- The
State Key Laboratory of Analytical Chemistry for Life Science, School
of Chemistry and Chemical Engineering, Nanjing University, Jiangsu 210093, China
| |
Collapse
|
107
|
Qiu QF, Zhang FL, Tang Y, Zhang XW, Jiang H, Liu YL, Huang WH. Real-time Monitoring of Exocytotic Glutamate Release from Single Neuron by Amperometry at an Enzymatic Biosensor. ELECTROANAL 2018. [DOI: 10.1002/elan.201700656] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Quan-Fa Qiu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Fu-Li Zhang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Yun Tang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Xin-Wei Zhang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Hong Jiang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Yan-Ling Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Wei-Hua Huang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| |
Collapse
|
108
|
Smith SK, Lugo‐Morales LZ, Tang C, Gosrani SP, Lee CA, Roberts JG, Morton SW, McCarty GS, Khan SA, Sombers LA. Quantitative Comparison of Enzyme Immobilization Strategies for Glucose Biosensing in Real‐Time Using Fast‐Scan Cyclic Voltammetry Coupled with Carbon‐Fiber Microelectrodes. Chemphyschem 2018; 19:1197-1204. [DOI: 10.1002/cphc.201701235] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Indexed: 11/12/2022]
Affiliation(s)
- Samantha K. Smith
- Department of Chemistry NC State University 2620 Yarbrough Dr., Campus Box 8204 Raleigh NC 27695-8204 USA
| | - Leyda Z. Lugo‐Morales
- Department of Chemistry NC State University 2620 Yarbrough Dr., Campus Box 8204 Raleigh NC 27695-8204 USA
| | - C. Tang
- Department of Chemical and Biomolecular Engineering NC State University, Centennial Campus 911 Partners Way, Campus Box 7905 Raleigh NC 27695-7905 USA
| | - Saahj P. Gosrani
- Department of Chemistry NC State University 2620 Yarbrough Dr., Campus Box 8204 Raleigh NC 27695-8204 USA
| | - Christie A. Lee
- Department of Chemistry NC State University 2620 Yarbrough Dr., Campus Box 8204 Raleigh NC 27695-8204 USA
| | - James G. Roberts
- Department of Chemistry NC State University 2620 Yarbrough Dr., Campus Box 8204 Raleigh NC 27695-8204 USA
| | - Stephen W. Morton
- Department of Chemistry NC State University 2620 Yarbrough Dr., Campus Box 8204 Raleigh NC 27695-8204 USA
- Department of Chemical and Biomolecular Engineering NC State University, Centennial Campus 911 Partners Way, Campus Box 7905 Raleigh NC 27695-7905 USA
| | - Gregory S. McCarty
- Department of Chemistry NC State University 2620 Yarbrough Dr., Campus Box 8204 Raleigh NC 27695-8204 USA
| | - Saad A. Khan
- Department of Chemical and Biomolecular Engineering NC State University, Centennial Campus 911 Partners Way, Campus Box 7905 Raleigh NC 27695-7905 USA
| | - Leslie A. Sombers
- Department of Chemistry NC State University 2620 Yarbrough Dr., Campus Box 8204 Raleigh NC 27695-8204 USA
| |
Collapse
|
109
|
Hu XB, Liu YL, Wang WJ, Zhang HW, Qin Y, Guo S, Zhang XW, Fu L, Huang WH. Biomimetic Graphene-Based 3D Scaffold for Long-Term Cell Culture and Real-Time Electrochemical Monitoring. Anal Chem 2018; 90:1136-1141. [DOI: 10.1021/acs.analchem.7b03324] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Affiliation(s)
- Xue-Bo Hu
- Key
Laboratory of Analytical Chemistry for Biology and Medicine (Ministry
of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Yan-Ling Liu
- Key
Laboratory of Analytical Chemistry for Biology and Medicine (Ministry
of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Wen-Jie Wang
- College
of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Hai-Wei Zhang
- Key
Laboratory of Analytical Chemistry for Biology and Medicine (Ministry
of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Yu Qin
- Key
Laboratory of Analytical Chemistry for Biology and Medicine (Ministry
of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Shan Guo
- Key
Laboratory of Analytical Chemistry for Biology and Medicine (Ministry
of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Xin-Wei Zhang
- Key
Laboratory of Analytical Chemistry for Biology and Medicine (Ministry
of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Lei Fu
- College
of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Wei-Hua Huang
- Key
Laboratory of Analytical Chemistry for Biology and Medicine (Ministry
of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| |
Collapse
|
110
|
Liu Y, Li J, Tschirhart T, Terrell JL, Kim E, Tsao C, Kelly DL, Bentley WE, Payne GF. Connecting Biology to Electronics: Molecular Communication via Redox Modality. Adv Healthc Mater 2017; 6. [PMID: 29045017 DOI: 10.1002/adhm.201700789] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2017] [Revised: 08/18/2017] [Indexed: 12/13/2022]
Abstract
Biology and electronics are both expert at for accessing, analyzing, and responding to information. Biology uses ions, small molecules, and macromolecules to receive, analyze, store, and transmit information, whereas electronic devices receive input in the form of electromagnetic radiation, process the information using electrons, and then transmit output as electromagnetic waves. Generating the capabilities to connect biology-electronic modalities offers exciting opportunities to shape the future of biosensors, point-of-care medicine, and wearable/implantable devices. Redox reactions offer unique opportunities for bio-device communication that spans the molecular modalities of biology and electrical modality of devices. Here, an approach to search for redox information through an interactive electrochemical probing that is analogous to sonar is adopted. The capabilities of this approach to access global chemical information as well as information of specific redox-active chemical entities are illustrated using recent examples. An example of the use of synthetic biology to recognize external molecular information, process this information through intracellular signal transduction pathways, and generate output responses that can be detected by electrical modalities is also provided. Finally, exciting results in the use of redox reactions to actuate biology are provided to illustrate that synthetic biology offers the potential to guide biological response through electrical cues.
Collapse
Affiliation(s)
- Yi Liu
- Institute for Bioscience and Biotechnology Research and Fischell Department of Bioengineering University of Maryland College Park MD 20742 USA
| | - Jinyang Li
- Institute for Bioscience and Biotechnology Research and Fischell Department of Bioengineering University of Maryland College Park MD 20742 USA
| | - Tanya Tschirhart
- Institute for Bioscience and Biotechnology Research and Fischell Department of Bioengineering University of Maryland College Park MD 20742 USA
| | - Jessica L. Terrell
- Institute for Bioscience and Biotechnology Research and Fischell Department of Bioengineering University of Maryland College Park MD 20742 USA
| | - Eunkyoung Kim
- Institute for Bioscience and Biotechnology Research and Fischell Department of Bioengineering University of Maryland College Park MD 20742 USA
| | - Chen‐Yu Tsao
- Institute for Bioscience and Biotechnology Research and Fischell Department of Bioengineering University of Maryland College Park MD 20742 USA
| | - Deanna L. Kelly
- Maryland Psychiatric Research Center University of Maryland School of Medicine Baltimore MD 21228 USA
| | - William E. Bentley
- Institute for Bioscience and Biotechnology Research and Fischell Department of Bioengineering University of Maryland College Park MD 20742 USA
| | - Gregory F. Payne
- Institute for Bioscience and Biotechnology Research and Fischell Department of Bioengineering University of Maryland College Park MD 20742 USA
| |
Collapse
|
111
|
Shin M, Field TM, Stucky CS, Furgurson MN, Johnson MA. Ex Vivo Measurement of Electrically Evoked Dopamine Release in Zebrafish Whole Brain. ACS Chem Neurosci 2017; 8:1880-1888. [PMID: 28617576 DOI: 10.1021/acschemneuro.7b00022] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Abstract
Zebrafish (Danio rerio) have recently emerged as useful model organism for the study of neuronal function. Here, fast-scan cyclic voltammetry (FSCV) at carbon-fiber microelectrodes was used to measure locally evoked dopamine release and uptake in zebrafish whole brain preparations and results were compared with those obtained from brain slices. Evoked dopamine release ([DA]max) was similar in whole brain and sagittal brain slice preparations (0.49 ± 0.13 μM in whole brain and 0.59 ± 0.28 μM in brain slices). Treatment with α-methyl-p-tyrosine methyl ester (αMPT), an inhibitor of tyrosine hydroxylase, diminished release and the electrochemical signal reappeared after subsequent drug washout. No observed change in stimulated release current occurred after treatment with desipramine or fluoxetine in the whole brain. Treatment with the uptake inhibitors, nomifensine or GBR 12909 increased [DA]max, while treatment with sulpiride, a D2 dopamine autoreceptor antagonist, resulted in increased stimulated dopamine release in whole brain, but had no effect on release in slices. Dopamine release in whole brains increased progressively up to an electrical stimulation frequency of 25 Hz, while release in slices increased up to a frequency of only 10 Hz and then plateaued, highlighting another key difference between these preparations. We observed a lag in peak dopamine release following stimulation, which we address using diffusion models and pharmacological treatments. Collectively, these results demonstrate the electrochemical determination of dopamine release in the whole, intact brain of a vertebrate species ex vivo and are an important step for carrying out further experiments in zebrafish.
Collapse
Affiliation(s)
- Mimi Shin
- Department of Chemistry, 1251 Wescoe Hall Drive, University of Kansas, Lawrence, Kansas 66045, United States
| | - Thomas M. Field
- Department of Chemistry, 1251 Wescoe Hall Drive, University of Kansas, Lawrence, Kansas 66045, United States
| | - Chase S. Stucky
- Department of Chemistry, 1251 Wescoe Hall Drive, University of Kansas, Lawrence, Kansas 66045, United States
| | - Mia N. Furgurson
- Department of Chemistry, 1251 Wescoe Hall Drive, University of Kansas, Lawrence, Kansas 66045, United States
| | - Michael A. Johnson
- Department of Chemistry, 1251 Wescoe Hall Drive, University of Kansas, Lawrence, Kansas 66045, United States
| |
Collapse
|
112
|
Tavakoli J, Tang Y. Hydrogel Based Sensors for Biomedical Applications: An Updated Review. Polymers (Basel) 2017; 9:E364. [PMID: 30971040 PMCID: PMC6418953 DOI: 10.3390/polym9080364] [Citation(s) in RCA: 211] [Impact Index Per Article: 26.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2017] [Revised: 08/10/2017] [Accepted: 08/12/2017] [Indexed: 02/07/2023] Open
Abstract
Biosensors that detect and convert biological reactions to a measurable signal have gained much attention in recent years. Between 1950 and 2017, more than 150,000 papers have been published addressing the applications of biosensors in different industries, but to the best of our knowledge and through careful screening, critical reviews that describe hydrogel based biosensors for biomedical applications are rare. This review discusses the biomedical application of hydrogel based biosensors, based on a search performed through Web of Science Core, PubMed (NLM), and Science Direct online databases for the years 2000⁻2017. In this review, we consider bioreceptors to be immobilized on hydrogel based biosensors, their advantages and disadvantages, and immobilization techniques. We identify the hydrogels that are most favored for this type of biosensor, as well as the predominant transduction strategies. We explain biomedical applications of hydrogel based biosensors including cell metabolite and pathogen detection, tissue engineering, wound healing, and cancer monitoring, and strategies for small biomolecules such as glucose, lactate, urea, and cholesterol detection are identified.
Collapse
Affiliation(s)
- Javad Tavakoli
- Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide 5042, SA, Australia.
| | - Youhong Tang
- Institute for Nano Scale Science & Technology, College of Science and Engineering, Flinders University, Adelaide 5042, SA, Australia.
| |
Collapse
|
113
|
Mitchell EC, Dunaway LE, McCarty GS, Sombers LA. Spectroelectrochemical Characterization of the Dynamic Carbon-Fiber Surface in Response to Electrochemical Conditioning. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2017; 33:7838-7846. [PMID: 28715197 DOI: 10.1021/acs.langmuir.7b01443] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The effects of electrochemical preconditioning of P-55 pitch-based carbon-fiber microelectrodes were quantitatively examined in this study. Microstructural characterization of the electrode surface was done using Raman spectroscopy and scanning electron microscopy. Electrochemical performance was evaluated using cyclic voltammetry. The data show that application of positive potentials provides beneficial structural modifications to the electrode surface. Electrodes that were preconditioned using a static potential of +1.0 V exhibited enhanced sensitivity and electron transfer properties when compared to electrodes conditioned for the same amount of time with dynamic (triangular) waveforms reaching +1.0 V. Conditioning elicited microstructural changes to the electrode surface that were dependent on the amount of time spent at potentials greater than ∼1.0 V. Importantly, the data demonstrate that the carbon-fiber microstructure is dynamic. It is able to quickly and continuously undergo rapid structural reorganization as potential is applied, repeatedly alternating between a relatively ordered state and one that exhibits greater disorder in response to applied electrochemical potentials that span the range commonly used in voltammetric experiments.
Collapse
Affiliation(s)
- Edwin C Mitchell
- Department of Chemistry, North Carolina State University , Raleigh, North Carolina 27695, United States
| | - Lars E Dunaway
- Department of Chemistry, North Carolina State University , Raleigh, North Carolina 27695, United States
| | - Gregory S McCarty
- Department of Chemistry, North Carolina State University , Raleigh, North Carolina 27695, United States
| | - Leslie A Sombers
- Department of Chemistry, North Carolina State University , Raleigh, North Carolina 27695, United States
| |
Collapse
|
114
|
Zhou J, Jiang D, Chen HY. Nanoelectrochemical architectures for high-spatial-resolution single cell analysis. Sci China Chem 2017. [DOI: 10.1007/s11426-017-9109-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
115
|
Liu YL, Qin Y, Jin ZH, Hu XB, Chen MM, Liu R, Amatore C, Huang WH. A Stretchable Electrochemical Sensor for Inducing and Monitoring Cell Mechanotransduction in Real Time. Angew Chem Int Ed Engl 2017. [DOI: 10.1002/anie.201705215] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Affiliation(s)
- Yan-Ling Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Yu Qin
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Zi-He Jin
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Xue-Bo Hu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Miao-Miao Chen
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Rong Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Christian Amatore
- PASTEUR; Département de chimie; École normale supérieure; PSL Research University; Sorbonne Universités; UPMC Univ. Paris 06, CNRS; 24 rue Lhomond 75005 Paris France
- State Key Laboratory of Physical Chemistry of Solid Surfaces; College of Chemistry and Chemical Engineering; Xiamen University; China
| | - Wei-Hua Huang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| |
Collapse
|
116
|
Liu YL, Qin Y, Jin ZH, Hu XB, Chen MM, Liu R, Amatore C, Huang WH. A Stretchable Electrochemical Sensor for Inducing and Monitoring Cell Mechanotransduction in Real Time. Angew Chem Int Ed Engl 2017. [DOI: 10.1002/ange.201705215] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Yan-Ling Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Yu Qin
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Zi-He Jin
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Xue-Bo Hu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Miao-Miao Chen
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Rong Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Christian Amatore
- PASTEUR; Département de chimie; École normale supérieure; PSL Research University; Sorbonne Universités; UPMC Univ. Paris 06, CNRS; 24 rue Lhomond 75005 Paris France
- State Key Laboratory of Physical Chemistry of Solid Surfaces; College of Chemistry and Chemical Engineering; Xiamen University; China
| | - Wei-Hua Huang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| |
Collapse
|
117
|
Guo W, Liu Y, Cao Z, Su B. Imaging Analysis Based on Electrogenerated Chemiluminescence. JOURNAL OF ANALYSIS AND TESTING 2017. [DOI: 10.1007/s41664-017-0013-9] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
118
|
Zhang H, Oellers T, Feng W, Abdulazim T, Saw EN, Ludwig A, Levkin PA, Plumeré N. High-Density Droplet Microarray of Individually Addressable Electrochemical Cells. Anal Chem 2017; 89:5832-5839. [DOI: 10.1021/acs.analchem.7b00008] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Affiliation(s)
- Huijie Zhang
- Center
for Electrochemical Sciences—CES, Ruhr-Universität Bochum, Universitätsstrasse 150, 44780 Bochum, Germany
| | - Tobias Oellers
- Chair
of MEMS Materials, Institute for Materials, Faculty of Mechanical
Engineering, Ruhr-Universität Bochum, Universitätsstrasse 150, 44780 Bochum, Germany
| | - Wenqian Feng
- Institute
of Toxicology and Genetics, Karlsruhe Institute of Technology (KIT), 76021 Karlsruhe, Germany
| | - Tarik Abdulazim
- Center
for Electrochemical Sciences—CES, Ruhr-Universität Bochum, Universitätsstrasse 150, 44780 Bochum, Germany
| | - En Ning Saw
- Center
for Electrochemical Sciences—CES, Ruhr-Universität Bochum, Universitätsstrasse 150, 44780 Bochum, Germany
| | - Alfred Ludwig
- Chair
of MEMS Materials, Institute for Materials, Faculty of Mechanical
Engineering, Ruhr-Universität Bochum, Universitätsstrasse 150, 44780 Bochum, Germany
| | - Pavel A. Levkin
- Institute
of Toxicology and Genetics, Karlsruhe Institute of Technology (KIT), 76021 Karlsruhe, Germany
- Institute
of Organic Chemistry, Karlsruhe Institute of Technology (KIT), 76021 Karlsruhe, Germany
| | - Nicolas Plumeré
- Center
for Electrochemical Sciences—CES, Ruhr-Universität Bochum, Universitätsstrasse 150, 44780 Bochum, Germany
| |
Collapse
|
119
|
Zhao X, Zhang Q, Chen H, Liu G, Bai W. Highly Sensitive Molecularly Imprinted Sensor Based on Platinum Thin-film Microelectrode for Detection of Chloramphenicol in Food Samples. ELECTROANAL 2017. [DOI: 10.1002/elan.201700164] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Xiaojuan Zhao
- College of Light Industry and Food Science; Zhongkai University of Agriculture and Engineering; Guangzhou 510225 P. R. China
- Key Laboratory of Traditional Cantonese Food Processing and Safety Control; Guangzhou 510225 P. R. China
| | - Qimei Zhang
- College of Light Industry and Food Science; Zhongkai University of Agriculture and Engineering; Guangzhou 510225 P. R. China
- Shenzhen Academy of Metrology and Quality Inspection; Shenzhen 518109 P. R. China
| | - Haiguang Chen
- College of Light Industry and Food Science; Zhongkai University of Agriculture and Engineering; Guangzhou 510225 P. R. China
- Key Laboratory of Traditional Cantonese Food Processing and Safety Control; Guangzhou 510225 P. R. China
| | - Gongliang Liu
- College of Light Industry and Food Science; Zhongkai University of Agriculture and Engineering; Guangzhou 510225 P. R. China
- Key Laboratory of Traditional Cantonese Food Processing and Safety Control; Guangzhou 510225 P. R. China
| | - Weidong Bai
- College of Light Industry and Food Science; Zhongkai University of Agriculture and Engineering; Guangzhou 510225 P. R. China
- Key Laboratory of Traditional Cantonese Food Processing and Safety Control; Guangzhou 510225 P. R. China
| |
Collapse
|
120
|
Bilatto SER, Adly NY, Correa DS, Wolfrum B, Offenhäusser A, Yakushenko A. Printed microfluidic filter for heparinized blood. BIOMICROFLUIDICS 2017; 11:034101. [PMID: 28798855 PMCID: PMC5533500 DOI: 10.1063/1.4982963] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Accepted: 04/24/2017] [Indexed: 05/25/2023]
Abstract
A simple lab-on-a-chip method for blood plasma separation was developed by combining stereolithographic 3D printing with inkjet printing, creating a completely sealed microfluidic device. In some approaches, one dilutes the blood sample before separation, reducing the concentration of a target analyte and increasing a contamination risk. In this work, a single drop (8 μl) of heparinized whole blood could be efficiently filtered using a capillary effect without any external driving forces and without dilution. The blood storage in heparin tubes during 24 h at 4 °C initiated the formation of small crystals that formed auto-filtration structures in the sample upon entering the 3D-printed device, with pores smaller than the red blood cells, separating plasma from the cellular content. The total filtration process took less than 10 s. The presented printed plasma filtration microfluidics fabricated with a rapid prototyping approach is a miniaturized, fast and easy-to-operate device that can be integrated into healthcare/portable systems for point-of-care diagnostics.
Collapse
Affiliation(s)
| | - Nouran Y Adly
- Institute of Bioelectronics (PGI-8/ICS-8), Forschungszentrum Jülich, 52425 Jülich, Germany
| | | | | | - Andreas Offenhäusser
- Institute of Bioelectronics (PGI-8/ICS-8), Forschungszentrum Jülich, 52425 Jülich, Germany
| | - Alexey Yakushenko
- Institute of Bioelectronics (PGI-8/ICS-8), Forschungszentrum Jülich, 52425 Jülich, Germany
| |
Collapse
|
121
|
Jin ZH, Liu YL, Chen JJ, Cai SL, Xu JQ, Huang WH. Conductive Polymer-Coated Carbon Nanotubes To Construct Stretchable and Transparent Electrochemical Sensors. Anal Chem 2017; 89:2032-2038. [DOI: 10.1021/acs.analchem.6b04616] [Citation(s) in RCA: 58] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Zi-He Jin
- Key Laboratory of Analytical
Chemistry for Biology and Medicine (Ministry of Education), College
of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Yan-Ling Liu
- Key Laboratory of Analytical
Chemistry for Biology and Medicine (Ministry of Education), College
of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Jing-Jing Chen
- Key Laboratory of Analytical
Chemistry for Biology and Medicine (Ministry of Education), College
of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Si-Liang Cai
- Key Laboratory of Analytical
Chemistry for Biology and Medicine (Ministry of Education), College
of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Jia-Quan Xu
- Key Laboratory of Analytical
Chemistry for Biology and Medicine (Ministry of Education), College
of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| | - Wei-Hua Huang
- Key Laboratory of Analytical
Chemistry for Biology and Medicine (Ministry of Education), College
of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, China
| |
Collapse
|
122
|
Xiao T, Wu F, Hao J, Zhang M, Yu P, Mao L. In Vivo Analysis with Electrochemical Sensors and Biosensors. Anal Chem 2016; 89:300-313. [DOI: 10.1021/acs.analchem.6b04308] [Citation(s) in RCA: 138] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Tongfang Xiao
- Beijing
National Laboratory for Molecular Sciences, CAS Key Laboratory of
Analytical Chemistry for Living Biosystems and Photochemistry, Institute
of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Fei Wu
- Beijing
National Laboratory for Molecular Sciences, CAS Key Laboratory of
Analytical Chemistry for Living Biosystems and Photochemistry, Institute
of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jie Hao
- Beijing
National Laboratory for Molecular Sciences, CAS Key Laboratory of
Analytical Chemistry for Living Biosystems and Photochemistry, Institute
of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Meining Zhang
- Beijing
National Laboratory for Molecular Sciences, CAS Key Laboratory of
Analytical Chemistry for Living Biosystems and Photochemistry, Institute
of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Ping Yu
- Beijing
National Laboratory for Molecular Sciences, CAS Key Laboratory of
Analytical Chemistry for Living Biosystems and Photochemistry, Institute
of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Lanqun Mao
- Beijing
National Laboratory for Molecular Sciences, CAS Key Laboratory of
Analytical Chemistry for Living Biosystems and Photochemistry, Institute
of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
123
|
A novel N-doped carbon nanotube fiber for selective and reliable electrochemical determination of ascorbic acid in rat brain microdialysates. J Electroanal Chem (Lausanne) 2016. [DOI: 10.1016/j.jelechem.2016.10.027] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
124
|
Hu XB, Liu YL, Zhang HW, Xiao C, Qin Y, Duo HH, Xu JQ, Guo S, Pang DW, Huang WH. Electrochemical Monitoring of Hydrogen Sulfide Release from Single Cells. ChemElectroChem 2016. [DOI: 10.1002/celc.201600411] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Xue-Bo Hu
- Key Laboratory of Analytical Chemistry for Biology and Medicine; Ministry of Education; College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 P. R. China
| | - Yan-Ling Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine; Ministry of Education; College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 P. R. China
| | - Hai-Wei Zhang
- Key Laboratory of Analytical Chemistry for Biology and Medicine; Ministry of Education; College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 P. R. China
| | - Chong Xiao
- Key Laboratory of Analytical Chemistry for Biology and Medicine; Ministry of Education; College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 P. R. China
| | - Yu Qin
- Key Laboratory of Analytical Chemistry for Biology and Medicine; Ministry of Education; College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 P. R. China
| | - Huan-Huan Duo
- Key Laboratory of Analytical Chemistry for Biology and Medicine; Ministry of Education; College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 P. R. China
| | - Jia-Quan Xu
- Key Laboratory of Analytical Chemistry for Biology and Medicine; Ministry of Education; College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 P. R. China
| | - Shan Guo
- Key Laboratory of Analytical Chemistry for Biology and Medicine; Ministry of Education; College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 P. R. China
| | - Dai-Wen Pang
- Key Laboratory of Analytical Chemistry for Biology and Medicine; Ministry of Education; College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 P. R. China
| | - Wei-Hua Huang
- Key Laboratory of Analytical Chemistry for Biology and Medicine; Ministry of Education; College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 P. R. China
| |
Collapse
|
125
|
Guo H, Kurokawa T, Takahata M, Hong W, Katsuyama Y, Luo F, Ahmed J, Nakajima T, Nonoyama T, Gong JP. Quantitative Observation of Electric Potential Distribution of Brittle Polyelectrolyte Hydrogels Using Microelectrode Technique. Macromolecules 2016. [DOI: 10.1021/acs.macromol.6b00037] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Affiliation(s)
- Honglei Guo
- Graduate
School of Life Science, Hokkaido University, Sapporo, 060-0810, Japan
| | - Takayuki Kurokawa
- Faculty
of Advanced Life Science, Hokkaido University, Sapporo, 060-0810, Japan
- Global
Station for Soft Matter, Global Institution for Collaborative Research
and Education, Hokkaido University, Sapporo, Japan
| | | | - Wei Hong
- Global
Station for Soft Matter, Global Institution for Collaborative Research
and Education, Hokkaido University, Sapporo, Japan
- Department
of Aerospace Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Yoshinori Katsuyama
- Faculty
of Advanced Life Science, Hokkaido University, Sapporo, 060-0810, Japan
| | - Feng Luo
- Faculty
of Advanced Life Science, Hokkaido University, Sapporo, 060-0810, Japan
| | - Jamil Ahmed
- Graduate
School of Life Science, Hokkaido University, Sapporo, 060-0810, Japan
| | - Tasuku Nakajima
- Faculty
of Advanced Life Science, Hokkaido University, Sapporo, 060-0810, Japan
- Global
Station for Soft Matter, Global Institution for Collaborative Research
and Education, Hokkaido University, Sapporo, Japan
| | - Takayuki Nonoyama
- Faculty
of Advanced Life Science, Hokkaido University, Sapporo, 060-0810, Japan
- Global
Station for Soft Matter, Global Institution for Collaborative Research
and Education, Hokkaido University, Sapporo, Japan
| | - Jian Ping Gong
- Faculty
of Advanced Life Science, Hokkaido University, Sapporo, 060-0810, Japan
- Global
Station for Soft Matter, Global Institution for Collaborative Research
and Education, Hokkaido University, Sapporo, Japan
| |
Collapse
|
126
|
Li Y, Meunier A, Fulcrand R, Sella C, Amatore C, Thouin L, Lemaître F, Guille-Collignon M. Multi-chambers Microsystem for Simultaneous and Direct Electrochemical Detection of Reactive Oxygen and Nitrogen Species Released by Cell Populations. ELECTROANAL 2016. [DOI: 10.1002/elan.201501157] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Yun Li
- Ecole Normale Supérieure-PSL Research University, Département de Chimie; Sorbonne Universités - UPMC Univ Paris 06, CNRS UMR 8640 PASTEUR; 24, rue Lhomond 75005 Paris France
| | - Anne Meunier
- Ecole Normale Supérieure-PSL Research University, Département de Chimie; Sorbonne Universités - UPMC Univ Paris 06, CNRS UMR 8640 PASTEUR; 24, rue Lhomond 75005 Paris France
| | - Rémy Fulcrand
- Ecole Normale Supérieure-PSL Research University, Département de Chimie; Sorbonne Universités - UPMC Univ Paris 06, CNRS UMR 8640 PASTEUR; 24, rue Lhomond 75005 Paris France
| | - Catherine Sella
- Ecole Normale Supérieure-PSL Research University, Département de Chimie; Sorbonne Universités - UPMC Univ Paris 06, CNRS UMR 8640 PASTEUR; 24, rue Lhomond 75005 Paris France
| | - Christian Amatore
- Ecole Normale Supérieure-PSL Research University, Département de Chimie; Sorbonne Universités - UPMC Univ Paris 06, CNRS UMR 8640 PASTEUR; 24, rue Lhomond 75005 Paris France
| | - Laurent Thouin
- Ecole Normale Supérieure-PSL Research University, Département de Chimie; Sorbonne Universités - UPMC Univ Paris 06, CNRS UMR 8640 PASTEUR; 24, rue Lhomond 75005 Paris France
| | - Frédéric Lemaître
- Ecole Normale Supérieure-PSL Research University, Département de Chimie; Sorbonne Universités - UPMC Univ Paris 06, CNRS UMR 8640 PASTEUR; 24, rue Lhomond 75005 Paris France
| | - Manon Guille-Collignon
- Ecole Normale Supérieure-PSL Research University, Département de Chimie; Sorbonne Universités - UPMC Univ Paris 06, CNRS UMR 8640 PASTEUR; 24, rue Lhomond 75005 Paris France
| |
Collapse
|
127
|
Liu YL, Jin ZH, Liu YH, Hu XB, Qin Y, Xu JQ, Fan CF, Huang WH. Stretchable Electrochemical Sensor for Real-Time Monitoring of Cells and Tissues. Angew Chem Int Ed Engl 2016; 55:4537-41. [PMID: 26929123 DOI: 10.1002/anie.201601276] [Citation(s) in RCA: 82] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2016] [Indexed: 01/19/2023]
Abstract
Stretchable electrochemical sensors are conceivably a powerful technique that provides important chemical information to unravel elastic and curvilinear living body. However, no breakthrough was made in stretchable electrochemical device for biological detection. Herein, we synthesized Au nanotubes (NTs) with large aspect ratio to construct an effective stretchable electrochemical sensor. Interlacing network of Au NTs endows the sensor with desirable stability against mechanical deformation, and Au nanostructure provides excellent electrochemical performance and biocompatibility. This allows for the first time, real-time electrochemical monitoring of mechanically sensitive cells on the sensor both in their stretching-free and stretching states as well as sensing of the inner lining of blood vessels. The results demonstrate the great potential of this sensor in electrochemical detection of living body, opening a new window for stretchable electrochemical sensor in biological exploration.
Collapse
Affiliation(s)
- Yan-Ling Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Zi-He Jin
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Yan-Hong Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Xue-Bo Hu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Yu Qin
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Jia-Quan Xu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Cui-Fang Fan
- Department of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Wei-Hua Huang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China.
| |
Collapse
|
128
|
Siraj S, McRae CR, Wong DK. Effective activation of physically small carbon electrodes by n-butylsilane reduction. Electrochem commun 2016. [DOI: 10.1016/j.elecom.2016.01.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023] Open
|
129
|
Liu YL, Jin ZH, Liu YH, Hu XB, Qin Y, Xu JQ, Fan CF, Huang WH. Stretchable Electrochemical Sensor for Real-Time Monitoring of Cells and Tissues. Angew Chem Int Ed Engl 2016. [DOI: 10.1002/ange.201601276] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Yan-Ling Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Zi-He Jin
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Yan-Hong Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Xue-Bo Hu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Yu Qin
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Jia-Quan Xu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| | - Cui-Fang Fan
- Department of Obstetrics and Gynecology; Renmin Hospital of Wuhan University; Wuhan 430060 China
| | - Wei-Hua Huang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education); College of Chemistry and Molecular Sciences; Wuhan University; Wuhan 430072 China
| |
Collapse
|
130
|
He R, Tang H, Jiang D, Chen HY. Electrochemical Visualization of Intracellular Hydrogen Peroxide at Single Cells. Anal Chem 2016; 88:2006-9. [DOI: 10.1021/acs.analchem.6b00150] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Affiliation(s)
- Ruiqin He
- The State
Key Lab of Analytical Chemistry for Life Science, School of Chemistry
and Chemical Engineering, Nanjing University, Nanjing, Jiangsu 210093, China
| | - Huifen Tang
- The State
Key Lab of Analytical Chemistry for Life Science, School of Chemistry
and Chemical Engineering, Nanjing University, Nanjing, Jiangsu 210093, China
| | - Dechen Jiang
- The State
Key Lab of Analytical Chemistry for Life Science, School of Chemistry
and Chemical Engineering, Nanjing University, Nanjing, Jiangsu 210093, China
| | - Hong-yuan Chen
- The State
Key Lab of Analytical Chemistry for Life Science, School of Chemistry
and Chemical Engineering, Nanjing University, Nanjing, Jiangsu 210093, China
| |
Collapse
|
131
|
Bai J, Wu L, Wang X, Zhang HM. Hemoglobin-graphene modified carbon fiber microelectrode for direct electrochemistry and electrochemical H2O2 sensing. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.10.100] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
132
|
Novel phenol biosensor based on laccase immobilized on reduced graphene oxide supported palladium–copper alloyed nanocages. Biosens Bioelectron 2015; 74:347-52. [DOI: 10.1016/j.bios.2015.06.060] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2015] [Revised: 06/15/2015] [Accepted: 06/25/2015] [Indexed: 01/05/2023]
|
133
|
Navratilova E, Atcherley CW, Porreca F. Brain Circuits Encoding Reward from Pain Relief. Trends Neurosci 2015; 38:741-750. [PMID: 26603560 PMCID: PMC4752429 DOI: 10.1016/j.tins.2015.09.003] [Citation(s) in RCA: 156] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2015] [Revised: 09/23/2015] [Accepted: 09/24/2015] [Indexed: 01/09/2023]
Abstract
Relief from pain in humans is rewarding and pleasurable. Primary rewards, or reward-predictive cues, are encoded in brain reward/motivational circuits. While considerable advances have been made in our understanding of reward circuits underlying positive reinforcement, less is known about the circuits underlying the hedonic and reinforcing actions of pain relief. We review findings from electrophysiological, neuroimaging, and behavioral studies supporting the concept that the rewarding effect of pain relief requires opioid signaling in the anterior cingulate cortex (ACC), activation of midbrain dopamine neurons, and the release of dopamine in the nucleus accumbens (NAc). Understanding of circuits that govern the reward of pain relief may allow the discovery of more effective and satisfying therapies for patients with acute or chronic pain.
Collapse
Affiliation(s)
- Edita Navratilova
- Department of Pharmacology, Arizona Health Sciences Center, University of Arizona, Tucson, AZ 85724, USA.
| | | | - Frank Porreca
- Department of Pharmacology, Arizona Health Sciences Center, University of Arizona, Tucson, AZ 85724, USA; Deparment of Research, Mayo Clinic, Scottsdale, AZ 85453, USA.
| |
Collapse
|
134
|
Qin WW, Wang SP, Li J, Peng TH, Xu Y, Wang K, Shi JY, Fan CH, Li D. Visualizing dopamine released from living cells using a nanoplasmonic probe. NANOSCALE 2015; 7:15070-15074. [PMID: 26348717 DOI: 10.1039/c5nr04433b] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We report the development of an ultrasensitive nanoplasmonic probe for discriminative detection and imaging of dopamine released from living cells. The sensing mechanism is based on the dopamine-induced seeded-growth of Au nanoparticles (Au NPs) that leads to the shift of the plasmon band. This platform allows for the detection of dopamine with a detection limit down to 0.25 pM within 1 min. This nanoplasmonic assay is further applied to visualize the release of dopamine from living rat pheochromocytoma (PC12) cells under ATP-stimulation with dark-field microscopy (DFM). The DFM results together with real time fluorescence imaging of PC12 cells stained with the Fluo calcium indicator, suggested that ATP stimulated-release of dopamine is concomitant with the Ca(2+) influx, and the influx of Ca(2+) is through ATP-activated channels instead of the voltage-gated Ca(2+) channel (VGC).
Collapse
Affiliation(s)
- W W Qin
- Division of Physical Biology & Bioimaging Centre, Shanghai Synchrotron Radiation Facility, CAS Key Laboratory of Interfacial Physics and Technology, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China.
| | | | | | | | | | | | | | | | | |
Collapse
|
135
|
Xu JQ, Liu YL, Wang Q, Duo HH, Zhang XW, Li YT, Huang WH. Photocatalytically Renewable Micro-electrochemical Sensor for Real-Time Monitoring of Cells. Angew Chem Int Ed Engl 2015. [DOI: 10.1002/ange.201507354] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
136
|
Xu J, Liu Y, Wang Q, Duo H, Zhang X, Li Y, Huang W. Photocatalytically Renewable Micro‐electrochemical Sensor for Real‐Time Monitoring of Cells. Angew Chem Int Ed Engl 2015; 54:14402-6. [DOI: 10.1002/anie.201507354] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Revised: 09/09/2015] [Indexed: 01/01/2023]
Affiliation(s)
- Jia‐Quan Xu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China)
| | - Yan‐Ling Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China)
| | - Qian Wang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China)
| | - Huan‐Huan Duo
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China)
| | - Xin‐Wei Zhang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China)
| | - Yu‐Tao Li
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China)
| | - Wei‐Hua Huang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China)
| |
Collapse
|
137
|
Lv X, Hu B, Wang Z, Peng J, Weng J. Two-Electron Oxidation of Dopamine Controlled by Surface Modification of Few-Layer Graphene. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.08.075] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
138
|
Zhou J, Ma G, Chen Y, Fang D, Jiang D, Chen HY. Electrochemiluminescence imaging for parallel single-cell analysis of active membrane cholesterol. Anal Chem 2015. [PMID: 26213787 DOI: 10.1021/acs.analchem.5b00542] [Citation(s) in RCA: 100] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Luminol electrochemiluminescence (ECL) imaging was developed for the parallel measurement of active membrane cholesterol at single living cells, thus establishing a novel electrochemical detection technique for single cells with high analysis throughput and low detection limit. In our strategy, the luminescence generated from luminol and hydrogen peroxide upon the potential was recorded in one image so that hydrogen peroxide at the surface of multiple cells could be simultaneously analyzed. Compared with the classic microelectrode array for the parallel single-cell analysis, the plat electrode only was needed in our ECL imaging, avoiding the complexity of electrode fabrication. The optimized ECL imaging system showed that hydrogen peroxide as low as 10 μM was visible and the efflux of hydrogen peroxide from cells could be determined. Coupled with the reaction between active membrane cholesterol and cholesterol oxidase to generate hydrogen peroxide, active membrane cholesterol at cells on the electrode was analyzed at single-cell level. The luminescence intensity was correlated with the amount of active membrane cholesterol, validating our system for single-cell cholesterol analysis. The relative high standard deviation on the luminescence suggested high cellular heterogeneities on hydrogen peroxide efflux and active membrane cholesterol, which exhibited the significance of single-cell analysis. This success in ECL imaging for single-cell analysis opens a new field in the parallel measurement of surface molecules at single cells.
Collapse
Affiliation(s)
- Junyu Zhou
- †School of Pharmacy, Nanjing Medical University, Jiangsu, 210000, China
| | - Guangzhong Ma
- ‡Key State Laboratory of Analytical Chemistry for Life Science and School of Chemistry and Chemical Engineering, Nanjing University, Jiangsu, 210093, China
| | - Yun Chen
- †School of Pharmacy, Nanjing Medical University, Jiangsu, 210000, China
| | - Danjun Fang
- †School of Pharmacy, Nanjing Medical University, Jiangsu, 210000, China
| | - Dechen Jiang
- ‡Key State Laboratory of Analytical Chemistry for Life Science and School of Chemistry and Chemical Engineering, Nanjing University, Jiangsu, 210093, China
| | - Hong-Yuan Chen
- ‡Key State Laboratory of Analytical Chemistry for Life Science and School of Chemistry and Chemical Engineering, Nanjing University, Jiangsu, 210093, China
| |
Collapse
|
139
|
Electrochemical evidence for asialoglycoprotein receptor – mediated hepatocyte adhesion and proliferation in three dimensional tissue engineering scaffolds. Anal Chim Acta 2015; 890:83-90. [DOI: 10.1016/j.aca.2015.06.057] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Revised: 04/30/2015] [Accepted: 06/30/2015] [Indexed: 11/18/2022]
|
140
|
Saylor RA, Reid EA, Lunte SM. Microchip electrophoresis with electrochemical detection for the determination of analytes in the dopamine metabolic pathway. Electrophoresis 2015; 36:1912-9. [PMID: 25958983 DOI: 10.1002/elps.201500150] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2015] [Revised: 04/10/2015] [Accepted: 04/14/2015] [Indexed: 12/23/2022]
Abstract
A method for the separation and detection of analytes in the dopamine metabolic pathway was developed using microchip electrophoresis with electrochemical detection. The microchip consisted of a 5 cm PDMS separation channel in a simple-t configuration. Analytes in the dopamine metabolic pathway were separated using a background electrolyte composed of 15 mM phosphate at pH 7.4, 15 mM SDS, and 2.5 mM boric acid. Two different microchip substrates using different electrode materials were compared for the analysis: a PDMS/PDMS device with a carbon fiber electrode and a PDMS/glass hybrid device with a pyrolyzed photoresist film carbon electrode. While the PDMS/PDMS device generated high separation efficiencies and good resolution, more reproducible migration times were obtained with the PDMS/glass hybrid device, making it a better choice for biological applications. Lastly, the optimized method was used to monitor l-DOPA metabolism in a rat brain slice.
Collapse
Affiliation(s)
- Rachel A Saylor
- Department of Chemistry, University of Kansas, Lawrence, KS, USA.,Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS, USA
| | - Erin A Reid
- Department of Chemistry, University of Kansas, Lawrence, KS, USA.,Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS, USA
| | - Susan M Lunte
- Department of Chemistry, University of Kansas, Lawrence, KS, USA.,Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS, USA.,Department of Pharmaceutical Chemistry, University of Kansas, Lawrence, KS, USA
| |
Collapse
|
141
|
Dejam M, Hassanzadeh H, Chen Z. Shear dispersion in combined pressure-driven and electro-osmotic flows in a capillary tube with a porous wall. AIChE J 2015. [DOI: 10.1002/aic.14897] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Affiliation(s)
- Morteza Dejam
- Dept. of Chemical and Petroleum Engineering; Schulich School of Engineering, University of Calgary; 2500 University Drive NW Calgary AB Canada T2N 1N4
| | - Hassan Hassanzadeh
- Dept. of Chemical and Petroleum Engineering; Schulich School of Engineering, University of Calgary; 2500 University Drive NW Calgary AB Canada T2N 1N4
| | - Zhangxin Chen
- Dept. of Chemical and Petroleum Engineering; Schulich School of Engineering, University of Calgary; 2500 University Drive NW Calgary AB Canada T2N 1N4
| |
Collapse
|
142
|
Maouche N, Ktari N, Bakas I, Fourati N, Zerrouki C, Seydou M, Maurel F, Chehimi MM. A surface acoustic wave sensor functionalized with a polypyrrole molecularly imprinted polymer for selective dopamine detection. J Mol Recognit 2015; 28:667-78. [DOI: 10.1002/jmr.2482] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2014] [Revised: 04/20/2015] [Accepted: 04/28/2015] [Indexed: 01/03/2023]
Affiliation(s)
- Naima Maouche
- Laboratoire d'Electrochimie et Matériaux; Université Sétif -1; 19000 Algeria
| | - Nadia Ktari
- Laboratoire Méthodes et Techniques d'Analyse; Institut National de Recherche et d'Analyse Physico-chimique, BiotechPole Sidi-Thabet; 2020 Ariana Tunisia
| | - Idriss Bakas
- Université Paris Diderot, Sorbonne Cité; ITODYS, UMR 7086 CNRS; 15 rue Jean Antoine de Baïf 75205 Paris Cedex13 France
| | - Najla Fourati
- SATIE, UMR 8029, CNRS, ENS-Cachan; Cnam; 292 rue Saint Martin 75003 Paris France
| | - Chouki Zerrouki
- SATIE, UMR 8029, CNRS, ENS-Cachan; Cnam; 292 rue Saint Martin 75003 Paris France
| | - Mahamadou Seydou
- Université Paris Diderot, Sorbonne Cité; ITODYS, UMR 7086 CNRS; 15 rue Jean Antoine de Baïf 75205 Paris Cedex13 France
| | - François Maurel
- Université Paris Diderot, Sorbonne Cité; ITODYS, UMR 7086 CNRS; 15 rue Jean Antoine de Baïf 75205 Paris Cedex13 France
| | - Mohammed Mehdi Chehimi
- Université Paris Diderot, Sorbonne Cité; ITODYS, UMR 7086 CNRS; 15 rue Jean Antoine de Baïf 75205 Paris Cedex13 France
- Université Paris Est, ICMPE, SPC, PoPI team, UPEC, 2-8 rue Henri Dunant; 94320 Thiais France
| |
Collapse
|
143
|
Koman VB, Santschi C, von Moos NR, Slaveykova VI, Martin OJ. Portable oxidative stress sensor: Dynamic and non-invasive measurements of extracellular H 2 O 2 released by algae. Biosens Bioelectron 2015; 68:245-252. [DOI: 10.1016/j.bios.2014.12.044] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2014] [Revised: 12/17/2014] [Accepted: 12/20/2014] [Indexed: 01/12/2023]
|
144
|
Abe H, Ino K, Li CZ, Kanno Y, Inoue KY, Suda A, Kunikata R, Matsudaira M, Takahashi Y, Shiku H, Matsue T. Electrochemical Imaging of Dopamine Release from Three-Dimensional-Cultured PC12 Cells Using Large-Scale Integration-Based Amperometric Sensors. Anal Chem 2015; 87:6364-70. [DOI: 10.1021/acs.analchem.5b01307] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Hiroya Abe
- Graduate School
of Environmental Studies, Tohoku University, 6-6-11-604 Aramaki-aza Aoba, Aoba-ku, Sendai 980-8579, Japan
| | - Kosuke Ino
- Graduate School
of Environmental Studies, Tohoku University, 6-6-11-604 Aramaki-aza Aoba, Aoba-ku, Sendai 980-8579, Japan
| | - Chen-Zhong Li
- Nanobioengineering/Nanobioelectronics Laboratory, Department
of Biomedical Engineering, Florida International University, 10555 West
Flagler Street, Miami, Florida 33174, United States
- WPI-Advanced Institute for Materials Research, Tohoku University, 2-1-1
Katahira, Aoba, Sendai 980-8577, Japan
| | - Yusuke Kanno
- Graduate School
of Environmental Studies, Tohoku University, 6-6-11-604 Aramaki-aza Aoba, Aoba-ku, Sendai 980-8579, Japan
| | - Kumi Y. Inoue
- Graduate School
of Environmental Studies, Tohoku University, 6-6-11-604 Aramaki-aza Aoba, Aoba-ku, Sendai 980-8579, Japan
| | - Atsushi Suda
- Japan Aviation Electronics Industry, Ltd. 1-1, Musashino 3-chome, Akishima-shi, Tokyo 196-8555, Japan
| | - Ryota Kunikata
- Japan Aviation Electronics Industry, Ltd. 1-1, Musashino 3-chome, Akishima-shi, Tokyo 196-8555, Japan
| | - Masahki Matsudaira
- Micro
System Integration Center, Tohoku University, 519-1176 Aramaki-aza Aoba, Aoba-ku, Sendai 980-0845, Japan
| | - Yasufumi Takahashi
- Graduate School
of Environmental Studies, Tohoku University, 6-6-11-604 Aramaki-aza Aoba, Aoba-ku, Sendai 980-8579, Japan
- WPI-Advanced Institute for Materials Research, Tohoku University, 2-1-1
Katahira, Aoba, Sendai 980-8577, Japan
- PRESTO, JST, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012, Japan
| | - Hitoshi Shiku
- Graduate School
of Environmental Studies, Tohoku University, 6-6-11-604 Aramaki-aza Aoba, Aoba-ku, Sendai 980-8579, Japan
| | - Tomokazu Matsue
- Graduate School
of Environmental Studies, Tohoku University, 6-6-11-604 Aramaki-aza Aoba, Aoba-ku, Sendai 980-8579, Japan
- WPI-Advanced Institute for Materials Research, Tohoku University, 2-1-1
Katahira, Aoba, Sendai 980-8577, Japan
| |
Collapse
|
145
|
Zhao XE, Zhu S, Yang H, You J, Song F, Liu Z, Liu S. Simultaneous determination of amino acid and monoamine neurotransmitters in PC12 cells and rats models of Parkinson's disease using a sensitizing derivatization reagent by UHPLC-MS/MS. J Chromatogr B Analyt Technol Biomed Life Sci 2015; 995-996:15-23. [PMID: 26021847 DOI: 10.1016/j.jchromb.2015.05.017] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2014] [Revised: 05/04/2015] [Accepted: 05/14/2015] [Indexed: 11/27/2022]
Abstract
Multi-analytes simultaneous monitoring of amino acid and monoamine neurotransmitters (NTs) has important scientific significance for their related pathology, physiology and drug screening. In this work, in virtue of a mass spectrometry sensitizing reagent 10-ethyl-acridone-3-sulfonyl chloride (EASC) as derivatization reagent, an Ultra High Performance Liquid Chromatography-Tandem Mass Spectrometry (UHPLC-MS/MS) method was developed and validated for simultaneous determination of six amino acid NTs, two monoamine ones and its one metabolite. The simple and rapid derivatization reaction was innovatively combined with plasma preparation by using EASC acetonitrile solution as protein precipitant. This interesting combination brought the advantages of speediness, simpleness and high-throughput in a cost-effective way. Under the optimized conditions, LODs (0.004-3.80nM) and LOQs (0.014-13.3nM) of EASC derivatized-NTs were calculated and found to be significantly lower than those of direct UHPLC-MS/MS detection about 11.5-275.0 and 14.4-371.4 times, respectively. Moreover, EASC derivatization significantly improved chromatographic resolution and matrix effect when compared with direct UPLC-MS/MS detection method without derivatization. Meanwhile, it also brought acceptable precision (3.0-13.0%, peak area CVs%), accuracy (86.4-112.9%), recovery (88.3-107.8%) and stability (3.8-8.5%, peak area CVs%) results. This method was successfully applied for the antiparkinsonian effect evaluation of levodopa and Ginsenoside Rg1 using PC12 cells and rats models by measuring multiple NTs. This provided a new method for the NTs related studies in the future.
Collapse
Affiliation(s)
- Xian-En Zhao
- Shandong Provincial Key Laboratory of Life-Organic Analysis, College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu 273165, Shandong, PR China; Changchun Center of Mass Spectrometry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, PR China.
| | - Shuyun Zhu
- Shandong Provincial Key Laboratory of Life-Organic Analysis, College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu 273165, Shandong, PR China
| | - Hongmei Yang
- Changchun Center of Mass Spectrometry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, PR China; Jilin Ginseng Academy, Changchun University of Chinese Medicine, Changchun 130117, China
| | - Jinmao You
- Shandong Provincial Key Laboratory of Life-Organic Analysis, College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu 273165, Shandong, PR China
| | - Fengrui Song
- Changchun Center of Mass Spectrometry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, PR China
| | - Zhiqiang Liu
- Changchun Center of Mass Spectrometry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, PR China
| | - Shuying Liu
- Changchun Center of Mass Spectrometry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, PR China; Jilin Ginseng Academy, Changchun University of Chinese Medicine, Changchun 130117, China.
| |
Collapse
|
146
|
Abstract
Digital simulations are a commonly used tool in electrochemical and electroanalytical research. However, even though the employed computational methods often feature significant complexity, testing routines are rarely specified or discussed in literature. In this work, we address this topic and describe approaches towards testing electrochemical simulation software. While focussing on simple systems featuring Nernstian reactions in 1 : 1 stoichiometries, we guide through rigorous testing processes of one- and two dimensional simulations with regard to applications in cyclic voltammetry. To this end, we compile expressions for the calculation of key values as references, discuss the conduction of convergence studies, and suggest approaches to automated software testing.
Collapse
Affiliation(s)
- Enno Kätelhön
- Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford, OX1 3QZ, UK.
| | | |
Collapse
|
147
|
Liang R, Broussard GJ, Tian L. Imaging chemical neurotransmission with genetically encoded fluorescent sensors. ACS Chem Neurosci 2015; 6:84-93. [PMID: 25565280 DOI: 10.1021/cn500280k] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
A major challenge in neuroscience is to decipher the logic of neural circuitry and to link it to learning, memory, and behavior. Synaptic transmission is a critical event underlying information processing within neural circuitry. In the extracellular space, the concentrations and distributions of excitatory, inhibitory, and modulatory neurotransmitters impact signal integration, which in turn shapes and refines the function of neural networks. Thus, the determination of the spatiotemporal relationships between these chemical signals with synaptic resolution in the intact brain is essential to decipher the codes for transferring information across circuitry and systems. Here, we review approaches and probes that have been employed to determine the spatial and temporal extent of neurotransmitter dynamics in the brain. We specifically focus on the design, screening, characterization, and application of genetically encoded indicators directly probing glutamate, the most abundant excitatory neurotransmitter. These indicators provide synaptic resolution of glutamate dynamics with cell-type specificity. We also discuss strategies for developing a suite of genetically encoded probes for a variety of neurotransmitters and neuromodulators.
Collapse
Affiliation(s)
- Ruqiang Liang
- Department
of Biochemistry and Molecular Medicine and ‡Center
for Neuroscience, University of California Davis, Davis, California 95817, United States
| | - Gerard Joseph Broussard
- Department
of Biochemistry and Molecular Medicine and ‡Center
for Neuroscience, University of California Davis, Davis, California 95817, United States
| | - Lin Tian
- Department
of Biochemistry and Molecular Medicine and ‡Center
for Neuroscience, University of California Davis, Davis, California 95817, United States
| |
Collapse
|
148
|
Saylor RA, Lunte SM. A review of microdialysis coupled to microchip electrophoresis for monitoring biological events. J Chromatogr A 2015; 1382:48-64. [PMID: 25637011 DOI: 10.1016/j.chroma.2014.12.086] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2014] [Revised: 12/23/2014] [Accepted: 12/26/2014] [Indexed: 12/30/2022]
Abstract
Microdialysis is a powerful sampling technique that enables monitoring of dynamic processes in vitro and in vivo. The combination of microdialysis with chromatographic or electrophoretic methods with selective detection yields a "separation-based sensor" capable of monitoring multiple analytes in near real time. For monitoring biological events, analysis of microdialysis samples often requires techniques that are fast (<1 min), have low volume requirements (nL-pL), and, ideally, can be employed on-line. Microchip electrophoresis fulfills these requirements and also permits the possibility of integrating sample preparation and manipulation with detection strategies directly on-chip. Microdialysis coupled to microchip electrophoresis has been employed for monitoring biological events in vivo and in vitro. This review discusses technical considerations for coupling microdialysis sampling and microchip electrophoresis, including various interface designs, and current applications in the field.
Collapse
Affiliation(s)
- Rachel A Saylor
- Department of Chemistry, University of Kansas, Lawrence, KS 66045, USA; Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS 66047, USA.
| | - Susan M Lunte
- Department of Chemistry, University of Kansas, Lawrence, KS 66045, USA; Department of Pharmaceutical Chemistry, University of Kansas, Lawrence, KS 66047, USA; Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS 66047, USA.
| |
Collapse
|
149
|
Zhang Z, Hao J, Xiao T, Yu P, Mao L. Online electrochemical systems for continuous neurochemical measurements with low-potential mediator-based electrochemical biosensors as selective detectors. Analyst 2015; 140:5039-47. [DOI: 10.1039/c5an00593k] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
This study demonstrates a new strategy to develop online electrochemical systems (OECSs) for continuously monitoring neurochemicals by efficiently integrating in vivo microdialysis with an oxidase-based electrochemical biosensor with low-potential electron mediators to shuttle the electron transfer of the oxidases.
Collapse
Affiliation(s)
- Zipin Zhang
- Beijing National Laboratory for Molecular Sciences
- Key Laboratory of Analytical Chemistry for Living Biosystems
- Institute of Chemistry
- The Chinese Academy of Sciences (CAS)
- Beijing 100190
| | - Jie Hao
- Beijing National Laboratory for Molecular Sciences
- Key Laboratory of Analytical Chemistry for Living Biosystems
- Institute of Chemistry
- The Chinese Academy of Sciences (CAS)
- Beijing 100190
| | - Tongfang Xiao
- Beijing National Laboratory for Molecular Sciences
- Key Laboratory of Analytical Chemistry for Living Biosystems
- Institute of Chemistry
- The Chinese Academy of Sciences (CAS)
- Beijing 100190
| | - Ping Yu
- Beijing National Laboratory for Molecular Sciences
- Key Laboratory of Analytical Chemistry for Living Biosystems
- Institute of Chemistry
- The Chinese Academy of Sciences (CAS)
- Beijing 100190
| | - Lanqun Mao
- Beijing National Laboratory for Molecular Sciences
- Key Laboratory of Analytical Chemistry for Living Biosystems
- Institute of Chemistry
- The Chinese Academy of Sciences (CAS)
- Beijing 100190
| |
Collapse
|
150
|
Bongard D, Bohr W, Swierczek M, Degefa TH, Walder L, Brandt R. Alkylene-bridged viologen dendrimers: versatile cell delivery tools with biosensing properties. Org Biomol Chem 2014; 12:9583-91. [PMID: 25335762 DOI: 10.1039/c4ob00560k] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The synthesis of two types of viologen dendrimers with peripheral carboxyl groups is described. Their interaction with plasmid DNA and CT-DNA and the influence of time evolution and electrolyte on dendriplex formation have been electrochemically investigated. A negative potential shift appearing in the cyclic voltammograms of the dendrimers indicates dendriplex formation on the time scale of 15 to 19 minutes, i.e. similar to those determined empirically for other dendrimer types. The presence or absence of the negative potential shift can be used to check the stability towards sodium chloride and different cell growth media directing to sucrose for cell incubation experiments. The electrolyte content of commercially available cell growth media inhibits the dendriplex formation in solution prior to plasmid addition. Furthermore, a low salt stability of 20 mM sodium chloride for viologen dendriplexes has been confirmed, also recommending the use of lysosomotropic sucrose. The two types of viologen dendrimers have been combined with two plasmids differing in the number of base pairs. Four immortal cell lines have been tested to check the suitability of viologen dendriplexes as gene delivery systems. Probably due to the absence of terminal amino groups and endosomolytic substances only a small transfection efficiency of dendriplexes was achieved at low pH, generally excluding in vivo applications. With the larger pHSV-eGFP plasmid (5743 bp) no transfected cells were observed indicating a preference for shorter plasmids.
Collapse
Affiliation(s)
- Dirk Bongard
- Institute of Chemistry of New Materials, University of Osnabrück, Barbarastr. 7, D-49076 Osnabrück, Germany.
| | | | | | | | | | | |
Collapse
|