101
|
Tonezzer T, Caffaro LAM, Menon KRS, Brandini da Silva FC, Moran de Brito CM, Sarri AJ, Casarotto RA. Effects of transcutaneous electrical nerve stimulation on chemotherapy-induced peripheral neuropathy symptoms (CIPN): a preliminary case-control study. J Phys Ther Sci 2017; 29:685-692. [PMID: 28533610 PMCID: PMC5430273 DOI: 10.1589/jpts.29.685] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2016] [Accepted: 01/10/2017] [Indexed: 01/19/2023] Open
Abstract
[Purpose] The aim of this double-blind, randomized and placebo-controlled study is to
investigate the effects of Transcutaneous Electrical Nerve Stimulation for reducing the
side effects of Chemotherapy-induced Peripheral Neuropathy in cancer patients undergoing
chemotherapy with oxaloplatin or paclitaxel. [Subjects and Methods] Twenty-four patients
were randomly allocated into two groups: active or placebo stimulation. All patients were
assessed for pain, numbness/tingiling, frequency of symptoms, and quality of life. The
transcutaneous Electrical Nerve Stimulation device was applied daily with modulating
frequencies ranging between 7 Hz and 65 Hz in distal limb regions during three cycles of
chemotherapy (45 days). The other stimulation parameters were: pulse duration of 200 μsec,
intensity at the highest tolerable level, and increases in intensity when it diminished.
[Results] The data showed no difference between active or placebo groups in terms of pain,
numbness/tingling, frequency of symptoms or impact on daily life activities. [Conclusion]
These results suggest that Transcutaneous Electrical Nerve Stimulation applied in the
frequency variation mode was not proven to be effective to improve the symptoms of
Chemotherapy-induced Peripheral Neuropathy during chemotherapy cycles. There was no
worsening of symptoms in subsequent cycles of the onset of symptoms of the disease.
Collapse
Affiliation(s)
- Tania Tonezzer
- Department of Rehabilitation Sciences in the School of Medicine, Department of Physical Therapy, Speech and Occupational Therapy, University of São Paulo, Brazil
| | - Leonardo Affonso Massabki Caffaro
- Department of Rehabilitation Sciences in the School of Medicine, Department of Physical Therapy, Speech and Occupational Therapy, University of São Paulo, Brazil
| | | | | | | | | | - Raquel Aparecida Casarotto
- Department of Physical Therapy, Speech and Occupational Therapy, School of Medicine of the University of São Paulo, Brazil
| |
Collapse
|
102
|
Hibbert AW, Billaut F, Varley MC, Polman RCJ. No Influence of Transcutaneous Electrical Nerve Stimulation on Exercise-Induced Pain and 5-Km Cycling Time-Trial Performance. Front Physiol 2017; 8:26. [PMID: 28223939 PMCID: PMC5293800 DOI: 10.3389/fphys.2017.00026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2016] [Accepted: 01/11/2017] [Indexed: 11/22/2022] Open
Abstract
Introduction: Afferent information from exercising muscle contributes to the sensation of exercise-induced muscle pain. Transcutaneous electrical nerve stimulation (TENS) delivers low–voltage electrical currents to the skin, inhibiting nociceptive afferent information. The use of TENS in reducing perceptions of exercise-induced pain has not yet been fully explored. This study aimed to investigate the effect of TENS on exercise-induced muscle pain, pacing strategy, and performance during a 5-km cycling time trial (TT). Methods: On three separate occasions, in a single-blind, randomized, and cross-over design, 13 recreationally active participants underwent a 30-min TENS protocol, before performing a 5-km cycling TT. TENS was applied to the quadriceps prior to exercise under the following conditions; control (CONT), placebo with sham TENS application (PLAC), and an experimental condition with TENS application (TENS). Quadriceps fatigue was assessed with magnetic femoral nerve stimulation assessing changes in potentiated quadriceps twitch force at baseline, pre and post exercise. Subjective scores of exertion, affect and pain were taken every 1-km. Results: During TTs, application of TENS did not influence pain perceptions (P = 0.68, ηp2 = 0.03). There was no significant change in mean power (P = 0.16, ηp2 = 0.16) or TT duration (P = 0.17, ηp2 = 0.14), although effect sizes were large for these two variables. Changes in power output were not significant but showed moderate effect sizes at 500-m (ηp2 = 0.10) and 750-m (ηp2 = 0.10). Muscle recruitment as inferred by electromyography data was not significant, but showed large effect sizes at 250-m (ηp2 = 0.16), 500-m (ηp2 = 0.15), and 750-m (ηp2 = 0.14). This indicates a possible effect for TENS influencing performance up to 1-km. Discussion: These findings do not support the use of TENS to improve 5-km TT performance.
Collapse
Affiliation(s)
- Andrew W Hibbert
- Institute of Sport, Exercise, and Active Living, Victoria UniversityMelbourne, VIC, Australia; College of Sport and Exercise Science, Victoria UniversityMelbourne, VIC, Australia
| | - François Billaut
- Institute of Sport, Exercise, and Active Living, Victoria UniversityMelbourne, VIC, Australia; Department of Kinesiology, University LavalQuebec, QC, Canada
| | - Matthew C Varley
- Institute of Sport, Exercise, and Active Living, Victoria University Melbourne, VIC, Australia
| | - Remco C J Polman
- Institute of Sport, Exercise, and Active Living, Victoria UniversityMelbourne, VIC, Australia; Psychology Department, Bournemouth UniversityBournemouth, UK
| |
Collapse
|
103
|
Problems, Solutions, and Strategies Reported by Users of Transcutaneous Electrical Nerve Stimulation for Chronic Musculoskeletal Pain: Qualitative Exploration Using Patient Interviews. Phys Ther 2016; 96:1039-48. [PMID: 26678446 DOI: 10.2522/ptj.20150272] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Accepted: 12/06/2015] [Indexed: 11/17/2022]
Abstract
BACKGROUND Transcutaneous electrical nerve stimulation (TENS) could offer a non-drug form of pain relief, but there is no consensus regarding its effectiveness for chronic musculoskeletal pain or chronic low back pain. A recent review of previous trial methods identified significant problems with low treatment fidelity. There is little information available to inform the development of a pragmatic implementation design for a TENS evaluation. OBJECTIVES The aim of this study was to explore the experiences of patients who were receiving secondary care in a pain clinic and who had expertise in using TENS to manage chronic musculoskeletal pain. These key informants were selected because they had the potential to generate knowledge that could inform research design and clinical practice. DESIGN A qualitative method using individual semistructured interviews with open questions was selected for its capacity to generate rich data. METHODS Semistructured interviews were conducted with 9 patients (6 women, 3 men). Thematic analysis was used as the primary data analysis method, and this analysis was enhanced by a case-level analysis of the context and processes of TENS use of each individual. RESULTS Data analysis indicated that patients learned to address a range of problems in order to optimize TENS use. Patients may need to personalize the positioning of electrodes and the TENS settings and to readjust them over time. Patients learned to use TENS in a strategic manner, and the outcomes of each strategy varied. CONCLUSIONS The findings indicated that a pragmatic TENS evaluation may need to incorporate a learning phase to allow patients to optimize this complex pattern of TENS usage, and evaluation may need to be sensitive to the outcomes of strategic use. These findings also have implications for clinical practice.
Collapse
|
104
|
Gozani SN. Fixed-site high-frequency transcutaneous electrical nerve stimulation for treatment of chronic low back and lower extremity pain. J Pain Res 2016; 9:469-79. [PMID: 27418854 PMCID: PMC4935001 DOI: 10.2147/jpr.s111035] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Objective The objective of this study was to determine if fixed-site high-frequency transcutaneous electrical nerve stimulation (FS-TENS) is effective in treating chronic low back and lower extremity pain. Background Transcutaneous electrical nerve stimulation is widely used for treatment of chronic pain. General-purpose transcutaneous electrical nerve stimulation devices are designed for stimulation anywhere on the body and often cannot be used while the user is active or sleeping. FS-TENS devices are designed for placement at a pre-determined location, which enables development of a wearable device for use over extended time periods. Methods Study participants with chronic low back and/or lower extremity pain self-administered an FS-TENS device for 60 days. Baseline, 30-, and 60-day follow-up data were obtained through an online questionnaire. The primary outcome measure was the patient global impression of change. Pain intensity and interference were assessed using the Brief Pain Inventory. Changes in use of concomitant pain medications were evaluated with a single-item global self-rating. Results One hundred and thirty participants were enrolled, with 88 completing the 60-day follow-up questionnaire. Most participants (73.9%) were 50 years of age or older. At baseline, low back pain was identified by 85.3%, lower extremity pain by 71.6%, and upper extremity pain by 62.5%. Participants reported widespread pain, at baseline, with a mean of 3.4 (standard deviation 1.1) pain sites. At the 60-day follow-up, 80.7% of participants reported that their chronic pain had improved and they were classified as responders. Baseline characteristics did not differentiate non-responders from responders. There were numerical trends toward reduced pain interference with walking ability and sleep, and greater pain relief in responders. There was a large difference in use of concomitant pain medications, with 80.3% of responders reporting a reduction compared to 11.8% of non-responders. Conclusion FS-TENS is a safe and effective option for treating chronic low back and lower extremity pain. These results motivate the use of FS-TENS in development of wearable analgesic devices.
Collapse
|
105
|
High- and low-frequency transcutaneous electrical nerve stimulation does not reduce experimental pain in elderly individuals. Pain 2016; 156:2093-2099. [PMID: 26101836 PMCID: PMC4770382 DOI: 10.1097/j.pain.0000000000000276] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
High- and low-frequency transcutaneous electrical nerve stimulation is effective for reducing experimental heat pain in young individuals but not in older individuals. Despite its widespread clinical use, the efficacy of transcutaneous electrical nerve stimulation (TENS) remains poorly documented in elderly individuals. In this randomized, double-blind crossover study, we compared the efficacy of high-frequency (HF), low-frequency (LF), and placebo (P) TENS in a group of 15 elderly adults (mean age: 67 ± 5 years). The effect of HF-, LF-, and P-TENS was also evaluated in a group of 15 young individuals (26 ± 5 years; same study design) to validate the effectiveness of the TENS protocols that were used in the elderly group. Each participant came to the laboratory on 3 separate occasions to receive, in random order, HF-, LF-, and P-TENS. Pain intensity and pain perception thresholds were assessed before, during, and after TENS, using an experimental heat pain paradigm. For the young group, there was a significant decrease in pain intensity during and after HF- and LF-TENS when compared with baseline, with both HF- and LF-TENS being superior to P-TENS. In the older group, HF- and LF-TENS did not reduce pain when compared with baseline and no difference was observed between the 2 active TENS sessions and P-TENS. High-frequency, LF-, and P-TENS all increased pain thresholds in young individuals, whereas in older individuals, only LF-TENS increased pain thresholds. Taken together, these results suggest that TENS is effective in young, but not in older, individuals. Future studies should be conducted to confirm these results in pain populations and to identify strategies that could enhance the effect of TENS in the elderly.
Collapse
|
106
|
Elserty N, Kattabei O, Elhafez H. Effect of Fixed Versus Adjusted Transcutaneous Electrical Nerve Stimulation Amplitude on Chronic Mechanical Low Back Pain. J Altern Complement Med 2016; 22:557-62. [PMID: 27144300 DOI: 10.1089/acm.2015.0063] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVES This study aimed to investigate the effect of adjusting pulse amplitude of transcutaneous electrical nerve stimulation versus fixed pulse amplitude in treatment of chronic mechanical low back pain. DESIGN Randomized clinical trial. SETTING El-sahel Teaching Hospital, Egypt. PARTICIPANTS Forty-five patients with chronic low back pain assigned to three equal groups. Their ages ranged from 20 to 50 years. INTERVENTION The three groups received the same exercise program. Group A received transcutaneous electrical nerve stimulation with fixed pulse amplitude for 40 minutes. Group B received transcutaneous electrical nerve stimulation with adjusted pulse amplitude for 40 minutes, with the pulse amplitude adjusted every 5 minutes. Group C received exercises only. Treatment sessions were applied three times per week for 4 weeks for the three groups. OUTCOME MEASURES A visual analogue scale was used to assess pain severity, the Oswestry Disability Index was used to assess functional level, and a dual inclinometer was used to measure lumbar range of motion. Evaluations were performed before and after treatment. RESULTS Visual analogue scale, Oswestry Disability Index, and back range of motion significantly differed between the two groups that received transcutaneous electrical nerve stimulation and the control group and did not significantly differ between fixed and adjusted pulse amplitude of transcutaneous electrical nerve stimulation. CONCLUSION Adjusting pulse amplitude of transcutaneous electrical nerve stimulation does not produce a difference in the effect of transcutaneous electrical nerve stimulation used to treat chronic low back pain.
Collapse
Affiliation(s)
- Noha Elserty
- 1 Physical Therapy Department, El-Sahel Teaching Hospital , Cairo, Egypt
| | - Omaima Kattabei
- 2 Basic Science Department, Faculty of Physical Therapy, Cairo University , Cairo, Egypt
| | - Hytham Elhafez
- 2 Basic Science Department, Faculty of Physical Therapy, Cairo University , Cairo, Egypt
| |
Collapse
|
107
|
Kumaran B, Watson T. Radiofrequency-based treatment in therapy-related clinical practice – a narrative review. Part II: chronic conditions. PHYSICAL THERAPY REVIEWS 2016. [DOI: 10.1080/10833196.2015.1133034] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
108
|
Simon CB, Riley JL, Fillingim RB, Bishop MD, George SZ. Age Group Comparisons of TENS Response Among Individuals With Chronic Axial Low Back Pain. THE JOURNAL OF PAIN 2015; 16:1268-1279. [PMID: 26342650 PMCID: PMC4666741 DOI: 10.1016/j.jpain.2015.08.009] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2015] [Revised: 08/05/2015] [Accepted: 08/19/2015] [Indexed: 12/19/2022]
Abstract
UNLABELLED Chronic low back pain (CLBP) is a highly prevalent and disabling musculoskeletal pain condition among older adults. Transcutaneous electrical nerve stimulation (TENS) is commonly used to treat CLBP, however response to TENS in older adults compared with younger adults is untested. In a dose-response study stratified by age, 60 participants with axial CLBP (20 young, 20 middle-aged, 20 older) received four 20-minute sessions of high-frequency high-intensity TENS over a 2- to 3-week period in a laboratory-controlled setting. Experimental measures of pain sensitivity (mechanical pressure pain detection threshold) and central pain excitability (phasic heat temporal summation and heat aftersensations) were assessed before and after TENS. Episodic or immediate axial CLBP relief was assessed after TENS via measures of resting pain, movement-evoked-pain, and self-reported disability. Cumulative or prolonged axial CLBP relief was assessed by comparing daily pain reports across sessions. Independent of age, individuals experienced episodic increase in the pressure pain detection threshold and reduction in aftersensation after TENS application. Similarly, all groups, on average, experienced episodic axial CLBP relief via improved resting pain, movement-evoked pain, and disability report. Under this design, no cumulative effect was observed as daily pain did not improve for any age group across the 4 sessions. However, older adults received higher TENS amplitude across all sessions to achieve TENS responses similar to those in younger adults. These findings suggest that older adults experience similar episodic axial CLBP relief to that of younger individuals after high-frequency, high-intensity TENS when higher dose parameters are used. PERSPECTIVE This study examined age group differences in experimental and axial CLBP response to TENS, delivered under the current recommended parameters of strong, but tolerable amplitude. Older adults had comparable TENS response although at higher TENS amplitude than younger adults, which may have important mechanistic and clinical implications.
Collapse
Affiliation(s)
- Corey B Simon
- Department of Physical Therapy, College of Public Health and Health Professions, University of Florida, Gainesville, Florida; Pain Research & Intervention Center of Excellence, University of Florida, Gainesville, Florida.
| | - Joseph L Riley
- Pain Research & Intervention Center of Excellence, University of Florida, Gainesville, Florida
| | - Roger B Fillingim
- Pain Research & Intervention Center of Excellence, University of Florida, Gainesville, Florida
| | - Mark D Bishop
- Department of Physical Therapy, College of Public Health and Health Professions, University of Florida, Gainesville, Florida; Pain Research & Intervention Center of Excellence, University of Florida, Gainesville, Florida
| | - Steven Z George
- Department of Physical Therapy, College of Public Health and Health Professions, University of Florida, Gainesville, Florida; Pain Research & Intervention Center of Excellence, University of Florida, Gainesville, Florida
| |
Collapse
|
109
|
Direct and Indirect Benefits Reported by Users of Transcutaneous Electrical Nerve Stimulation for Chronic Musculoskeletal Pain: Qualitative Exploration Using Patient Interviews. Phys Ther 2015; 95:1518-28. [PMID: 25929534 DOI: 10.2522/ptj.20140120] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2014] [Accepted: 04/19/2015] [Indexed: 11/17/2022]
Abstract
BACKGROUND There is no consensus regarding the effectiveness of transcutaneous electrical nerve stimulation (TENS) for management of chronic musculoskeletal pain or chronic low back pain. A recent review of previous trial methodology identified significant problems with low treatment fidelity. There is little information available to guide selection of patient-reported outcome measures appropriate for TENS evaluation. OBJECTIVES The purpose of this study was to explore the experiences of patients at a secondary care pain clinic who successfully used TENS to help manage chronic musculoskeletal pain. These key informants were selected because they had the potential to generate knowledge that could inform research design and clinical practice. DESIGN A qualitative method using individual semistructured interviews with open questions was selected for its capacity to generate rich data. METHODS A mini focus group informed the development of a discussion guide for semistructured interviews with 9 patients (6 women, 3 men). Thematic analysis was used as the primary data analysis method, and this analysis was enhanced by a case-level analysis of the context and processes of TENS use of each individual. RESULTS Data analysis indicated that distraction from pain and a reduction in the sensations associated with muscle tension or spasm should be considered as separate outcomes from pain relief. These direct benefits led to a wide range of indirect benefits dependent on patient decision making, including medication reduction, enhanced function, psychological benefits, and enhanced ability to rest. CONCLUSIONS The findings indicate that evaluating TENS using a unidimensional pain scale is likely to overlook potential benefits. The complex pattern of TENS usage, as well as multiple direct and indirect outcomes, indicates that TENS could be considered as a complex intervention.
Collapse
|
110
|
Improved Walking Claudication Distance with Transcutaneous Electrical Nerve Stimulation. Am J Phys Med Rehabil 2015; 94:941-9. [PMID: 25802954 DOI: 10.1097/phm.0000000000000277] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
111
|
Catley MJ, Gibson W, Wand BM, Meads C, O'Connell NE. Transcutaneous Electrical Nerve Stimulation (TENS) for chronic pain - an overview of Cochrane reviews. THE COCHRANE DATABASE OF SYSTEMATIC REVIEWS 2015. [DOI: 10.1002/14651858.cd011890] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Mark J Catley
- University of South Australia; School of Health Sciences; GPO Box 2471 Adelaide South Australia Australia 5001
| | - William Gibson
- University of Notre Dame Australia; School of Physiotherapy; 19 Mouat Street (PO Box 1225) Fremantle Western Australia Australia 6959
| | - Benedict M Wand
- University of Notre Dame Australia; School of Physiotherapy; 19 Mouat Street (PO Box 1225) Fremantle Western Australia Australia 6959
| | - Catherine Meads
- Brunel University London; Health Economics Research Group, Institute for Environment Health and Societies; Kingston Lane London UK
| | - Neil E O'Connell
- Brunel University; Department of Clinical Sciences/Health Economics Research Group, Institute of Environment, Health and Societies; Kingston Lane Uxbridge Middlesex UK UB8 3PH
| |
Collapse
|
112
|
Johnson MI, Mulvey MR, Bagnall AM. Transcutaneous electrical nerve stimulation (TENS) for phantom pain and stump pain following amputation in adults. Cochrane Database Syst Rev 2015; 8:CD007264. [PMID: 26284511 PMCID: PMC7209768 DOI: 10.1002/14651858.cd007264.pub3] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
BACKGROUND This is the first update of a Cochrane review published in Issue 5, 2010 on transcutaneous electrical nerve stimulation (TENS) for phantom pain and stump pain following amputation in adults. Pain may present in a body part that has been amputated (phantom pain) or at the site of amputation (stump pain), or both. Phantom pain and stump pain are complex and multidimensional and the underlying pathophysiology remains unclear. The condition remains a severe burden for those who are affected by it. The mainstay treatments are predominately pharmacological, with increasing acknowledgement of the need for non-drug interventions. TENS has been recommended as a treatment option but there has been no systematic review of available evidence. Hence, the effectiveness of TENS for phantom pain and stump pain is currently unknown. OBJECTIVES To assess the analgesic effectiveness of TENS for the treatment of phantom pain and stump pain following amputation in adults. SEARCH METHODS For the original version of the review we searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, PsycINFO, AMED, CINAHL, PEDRO and SPORTDiscus (February 2010). For this update, we searched the same databases for relevant randomised controlled trials (RCTs) from 2010 to 25 March 2015. SELECTION CRITERIA We only included RCTs investigating the use of TENS for the management of phantom pain and stump pain following an amputation in adults. DATA COLLECTION AND ANALYSIS Two review authors independently assessed trial quality and extracted data. We planned that where available and appropriate, data from outcome measures were to be pooled and presented as an overall estimate of the effectiveness of TENS. MAIN RESULTS In the original review there were no RCTs that examined the effectiveness of TENS for the treatment of phantom pain and stump pain in adults. For this update, we did not identify any additional RCTs for inclusion. AUTHORS' CONCLUSIONS There were no RCTs to judge the effectiveness of TENS for the management of phantom pain and stump pain. The published literature on TENS for phantom pain and stump pain lacks the methodological rigour and robust reporting needed to confidently assess its effectiveness. Further RCT evidence is required before an assessment can be made. Since publication of the original version of this review, we have found no new studies and our conclusions remain unchanged.
Collapse
Affiliation(s)
- Mark I Johnson
- Faculty of Health and Social Sciences, Leeds Beckett University, City Campus, Calverley Street, Leeds, UK, LS1 3HE
| | | | | |
Collapse
|
113
|
Mira TAA, Giraldo PC, Yela DA, Benetti-Pinto CL. Effectiveness of complementary pain treatment for women with deep endometriosis through Transcutaneous Electrical Nerve Stimulation (TENS): randomized controlled trial. Eur J Obstet Gynecol Reprod Biol 2015; 194:1-6. [PMID: 26319650 DOI: 10.1016/j.ejogrb.2015.07.009] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2015] [Revised: 07/03/2015] [Accepted: 07/23/2015] [Indexed: 12/11/2022]
Abstract
OBJECTIVE Evaluate TENS effectiveness as a complementary treatment of chronic pelvic pain and deep dyspareunia in women with deep endometriosis. STUDY DESIGN This randomized controlled trial was performed in a tertiary health care center, including twenty-two women with deep endometriosis undergoing hormone therapy with persistent pelvic pain and/or deep dyspareunia. This study was registered in the Brazilian Record of Clinical Trials (ReBEC), under n RBR-3rndh6. TENS application for 8 weeks followed a randomized allocation into two groups: Group 1 - acupuncture-like TENS (Frequency: 8Hz, pulse duration: 250μs) - VIF (n=11) and Group 2 - self-applied TENS (Frequency: 85Hz, pulse duration: 75μs) (n=11). The intensity applied was "strong, but comfortable". We evaluated patients before and after treatment by the use of the Visual Analogue Scale, Deep Dyspareunia Scale and Endometriosis Quality of Life Questionnaire. We used the Wilcoxon and Mann-Whitney tests to compare before and after treatment conditions. RESULTS Despite the use of hormone therapy for 1.65±2.08 years, the 22 women with deep endometriosis sustained pelvic pain complaints (VAS=5.95±2.13 and 2.45±2.42, p<.001) and/or deep dyspareunia (DDS=2.29±0.46 and 1.20±1.01, p=.001). We observed significant improvement for chronic pelvic pain, deep dyspareunia and quality of life by the use of TENS. Both application types of TENS were effective for improving the evaluated types of pain. CONCLUSIONS Both resources (acupuncture-like TENS and self-applied TENS) demonstrated effectiveness as a complementary treatment of pelvic pain and deep dyspareunia, improving quality of life in women with deep endometriosis regardless of the device used for treatment.
Collapse
Affiliation(s)
- Ticiana A A Mira
- Department of Obstetrics and Gynecology, University of Campinas, Campinas, Brazil
| | - Paulo C Giraldo
- Department of Obstetrics and Gynecology, University of Campinas, Campinas, Brazil
| | - Daniela A Yela
- Department of Obstetrics and Gynecology, University of Campinas, Campinas, Brazil
| | | |
Collapse
|
114
|
Abstract
BACKGROUND This is a second update of a Cochrane Review originally published in Issue 2, 2009. Transcutaneous Electrical Nerve Stimulation (TENS) is a non-pharmacological agent, based on delivering low voltage electrical currents to the skin. TENS is used by people to treat a variety of pain conditions. OBJECTIVES To assess the analgesic effectiveness of TENS, as a sole treatment, for acute pain in adults. SEARCH METHODS We searched the following databases up to 3 December 2014: the Cochrane Central Register of Controlled Trials (CENTRAL), in the Cochrane Library; MEDLINE; EMBASE; CINAHL; and AMED. We also checked the reference lists of included trials. SELECTION CRITERIA We included randomised controlled trials (RCTs) of adults with acute pain (< 12 weeks) if they examined TENS given as a sole treatment and assessed pain with subjective pain scales. Trials were eligible if they compared TENS to placebo TENS, no treatment controls, pharmacological interventions or non-pharmacological interventions. We excluded trials on experimental pain, case reports, clinical observations, letters, abstracts or reviews. Also we excluded trials investigating the effect of TENS on pain during childbirth (labour), primary dysmenorrhoea or dental procedures. Studies where TENS was given with another treatment as part of the formal trial design were excluded. We did not restrict any articles based on language of publication. DATA COLLECTION AND ANALYSIS Two review authors independently assessed study eligibility and carried out study selection, data extraction, 'Risk of bias' assessment and analyses of data. We extracted data on the following: types of participants and pain condition, trial design and methods, treatment parameters, adverse effects, and outcome measures. We contacted trial authors for additional information if necessary. MAIN RESULTS We included 12 trials in the original review (2009) and included no further trials in the first update (2011). An additional seven new trials met the inclusion criteria in this second update. In total, we included 19 RCTs involving 1346 participants at entry, with 11 trials awaiting classification either because the full text was unavailable or information in the full text failed to clarify eligibility. We excluded most trials because TENS was given in combination with another treatment as part of the formal study design or TENS was not delivered using appropriate TENS technique. The types of acute pain included in this Cochrane Review were procedural pain, e.g. cervical laser treatment, venepuncture, screening flexible sigmoidoscopy and non-procedural pain, e.g. postpartum uterine contractions and rib fractures. We pooled data for pain intensity for six trials (seven comparisons) comparing TENS with placebo but the I(2) statistic suggested substantial heterogeneity. Mean difference (MD) with 95% confidence intervals (CIs) on a visual analogue scale (VAS, 100 mm) was -24.62 mm (95% CI -31.79 to -17.46) in favour of TENS. Data for the proportion of participants achieving ≥ 50% reduction in pain was pooled for four trials (seven comparisons) and relative risk was 3.91 (95% CI 2.42 to 6.32) in favour of TENS over placebo. We pooled data for pain intensity from five trials (seven comparisons) but the I(2) statistic suggested considerable heterogeneity. MD was -19.05 mm (95% CI -27.30 to -10.79) in favour of TENS using a random-effects model. It was not possible to pool other data. There was a high risk of bias associated with inadequate sample sizes in treatment arms and unsuccessful blinding of treatment interventions. Seven trials reported minor adverse effects, such as mild erythema and itching underneath the electrodes and participants disliking TENS sensation. AUTHORS' CONCLUSIONS This Cochrane Review update includes seven new trials, in addition to the 12 trials reviewed in the first update in 2011. The analysis provides tentative evidence that TENS reduces pain intensity over and above that seen with placebo (no current) TENS when administered as a stand-alone treatment for acute pain in adults. The high risk of bias associated with inadequate sample sizes in treatment arms and unsuccessful blinding of treatment interventions makes definitive conclusions impossible. There was incomplete reporting of treatment in many reports making replication of trials impossible.
Collapse
Affiliation(s)
- Mark I Johnson
- Faculty of Health and Social Sciences, Leeds Beckett University, City Campus, Calverley Street, Leeds, UK, LS1 3HE
| | | | | | | |
Collapse
|
115
|
Eckenrode BJ, Stackhouse SK. IMPROVED PRESSURE PAIN THRESHOLDS AND FUNCTION FOLLOWING NOXIOUS ELECTRICAL STIMULATION ON A RUNNER WITH CHRONIC ACHILLES TENDINOPATHY: A CASE REPORT. Int J Sports Phys Ther 2015; 10:354-362. [PMID: 26075151 PMCID: PMC4458923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023] Open
Abstract
BACKGROUND AND PURPOSE Achilles tendinopathy is a common overuse injury sustained by athletes including runners. The use of noxious electrical stimulation for the treatment of chronic tendinopathies is a novel treatment intervention, which may alter pain perception and serve as adjunct technique in the recovery of painfree function. The purpose of this case report is to demonstrate the use of noxious electrical stimulation for the treatment of chronic, bilateral Achilles tendinopathy that was resistant to conservative treatment using plantarflexor eccentric exercise. CASE DESCRIPTION A 27-year old male runner was referred to physical therapy with a 7-year history of bilateral Achilles tendinopathy. He scored a 73/80 on the Lower Extremity Functional Scale (LEFS) and a 64% on the Victorian Institute of Sports Assessment-Achilles (VISA-A). Pain pressure threshold testing of the Achilles tendon was performed, followed by a single session of noxious electric stimulation to bilateral Achilles tendons, and the subject was instructed to continue with eccentric gastroc-soleus complex strengthening as previously performed. OUTCOMES Pain pressure threshold testing was performed to the mid-portion of the posterior Achilles tendon. The left Achilles tendon mean was 10.50kg and right Achilles tendon was 8.33kg prior to the noxious stimulation intervention. Twenty-four hours after the noxious stimulation treatment, improvements in mean pain threshold testing were found for both the left (16.31kg) and right (12.36kg) Achilles tendons. At one month after the physical therapy noxious stimulation session, the subject was able to progress his workouts to include sprints and interval training. His LEFS improved to 76/80 and his VISA-A improved to 96%. DISCUSSION The case illustrates the successful pain reduction and return to progressive sports activity in a runner with chronic Achilles tendinopathy. The utilization of noxious electric stimulation may have altered the pain perception of the nervous system as evidenced by the improvement in pain pressure threshold testing. Future studies on the application of noxious electric stimulation on chronic Achilles tendinopathy may help support the benefit of this intervention on pain and function. LEVEL OF EVIDENCE Therapy, Level 4.
Collapse
|
116
|
Vance CGT, Dailey DL, Rakel BA, Sluka KA. Using TENS for pain control: the state of the evidence. Pain Manag 2015; 4:197-209. [PMID: 24953072 DOI: 10.2217/pmt.14.13] [Citation(s) in RCA: 212] [Impact Index Per Article: 21.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Transcutaneous electrical nerve stimulation (TENS) is a nonpharmacological intervention that activates a complex neuronal network to reduce pain by activating descending inhibitory systems in the central nervous system to reduce hyperalgesia. The evidence for TENS efficacy is conflicting and requires not only description but also critique. Population-specific systemic reviews and meta-analyses are emerging, indicating both HF and LF TENS being shown to provide analgesia, specifically when applied at a strong, nonpainful intensity. The purpose of this article is to provide a critical review of the latest basic science and clinical evidence for TENS. Additional research is necessary to determine if TENS has effects specific to mechanical stimuli and/or beyond reduction of pain and will improve activity levels, function and quality of life.
Collapse
Affiliation(s)
- Carol G T Vance
- The University of Iowa Physical Therapy & Rehabilitation Science Department, IA, USA
| | | | | | | |
Collapse
|
117
|
On "The American Physical Therapy Association's top five Choosing Wisely recommendations." White NT, Delitto A, Manal TJ, Miller S. Phys Ther. doi: 10.2522/ptj.20140287. Phys Ther 2015; 95:275-8. [PMID: 25639528 DOI: 10.2522/ptj.2015.95.2.275] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
|
118
|
Effect of transcutaneous electrical nerve stimulation on pain, function, and quality of life in fibromyalgia: a double-blind randomized clinical trial. Phys Ther 2015; 95:129-40. [PMID: 25212518 PMCID: PMC4295083 DOI: 10.2522/ptj.20140218] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
BACKGROUND Fibromyalgia is a common chronic pain condition that has a significant impact on quality of life and often leads to disability. To date, there have been few well-controlled trials assessing the utility of nonpharmacological treatment modalities such as transcutaneous electrical nerve stimulation (TENS) in the management of pain and improvement in function in individuals with fibromyalgia. OBJECTIVES The purpose of this study will be to complete a long-term, multicenter study to assess the effects of TENS in women with fibromyalgia. DESIGN This will be a phase II randomized, double-blind, placebo-controlled, multicenter clinical trial. PARTICIPANTS Three hundred forty-three participants with fibromyalgia will be recruited for this study. INTERVENTION Participants will be randomly assigned to 1 of 3 groups: the intervention (TENS), placebo, or no treatment. After completing the randomized period, all participants will receive the intervention for 1 month. The participants will be asked to use TENS at the highest tolerable level for at least 2 hours daily during physical activity. MEASUREMENTS The primary outcome will be pain with movement, with secondary outcomes assessing functional abilities, patient-reported outcomes, and quantitative sensory testing. LIMITATIONS Because having participants refrain from their typical medications is not practical, their usage and any change in medication use will be recorded. CONCLUSIONS The results of this study will provide some of the first evidence from a large-scale, double-blind, placebo-controlled trial on the effectiveness of TENS on pain control and quality-of-life changes in patients with fibromyalgia.
Collapse
|
119
|
Colvin LA, Dougherty PM. Peripheral neuropathic pain: signs, symptoms, mechanisms, and causes: are they linked? Br J Anaesth 2014; 114:361-3. [PMID: 25253232 DOI: 10.1093/bja/aeu323] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Affiliation(s)
- L A Colvin
- Department of Anaesthesia, Critical Care and Pain Medicine, University of Edinburgh, Western General Hospital, Crewe Rd, Edinburgh EH4 2XU, UK
| | - P M Dougherty
- Department of Anesthesiology and Pain Management, The University of Texas M.D. Anderson Cancer Center, 1400 Holcombe Boulevard Unit 409, Houston, TX 77030, USA
| |
Collapse
|
120
|
Management of a patient with chronic low back pain and multiple health conditions using a pain mechanisms-based classification approach. J Orthop Sports Phys Ther 2014; 44:403-C2. [PMID: 24766360 DOI: 10.2519/jospt.2014.4861] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
STUDY DESIGN Case report. BACKGROUND Pain can lead to a significant reduction in quality of life. A pain mechanisms-based classification scheme has been outlined to improve management of patients with pain, but studies describing its use are limited. Evidence for physical therapy interventions in those with chronic pain and multiple health conditions is also lacking. This case report describes management of a patient with chronic pain and multiple health conditions. CASE DESCRIPTION A 29-year-old man presented with a 3-year history of low back pain and 11-month history of lower extremity paresthesia. Current health conditions included left-sided hemiparesis secondary to a stroke, pancreatic kidney transplant, left-sided blindness, and osteoporosis secondary to hyperparathyroidism. Inability to walk to school and sit through class, and pain-related sleep disruption were the primary activity and participation restrictions. Outcome measures included the numeric pain rating scale, global rating of change, Oswestry Disability Index, and pain medication usage. A score of 12 on the Leeds assessment of neuropathic symptoms and signs (LANSS) pain scale indicated the presence of neuropathic pain, but other pain mechanisms were also hypothesized to be present. Treatment was designed to improve patient goals considering these pain mechanisms. OUTCOMES The patient was seen for 20 visits over 6 months. Ten months after the initial evaluation, the patient's Oswestry Disability Index scores improved by more than 50% and the patient achieved all initially stated goals without pain medication. DISCUSSION A pain mechanisms-based approach assisted in the management of a patient with chronic pain and multiple health conditions. Using this approach may enhance clinical decision making when managing individuals with chronic pain. LEVEL OF EVIDENCE Therapy, level 4.
Collapse
|
121
|
An interprofessional consensus of core competencies for prelicensure education in pain management: curriculum application for physical therapy. Phys Ther 2014; 94:451-65. [PMID: 24309615 PMCID: PMC4023081 DOI: 10.2522/ptj.20130346] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
122
|
Pivec R, Stokes M, Chitnis AS, Paulino CB, Harwin SF, Mont MA. Clinical and economic impact of TENS in patients with chronic low back pain: analysis of a nationwide database. Orthopedics 2013; 36:922-8. [PMID: 24579210 DOI: 10.3928/01477447-20131120-04] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
This study evaluated patients who were given transcutaneous electrical nerve stimulation (TENS) compared with a matched group without TENS prior to intervention and at 1-year follow-up. Patients who were treated with TENS had significantly fewer hospital and clinic visits, used less diagnostic imaging (31 vs 46 events per 100 patients), had fewer physical therapy visits (94 vs 107), and required less back surgery (7.5 vs 9.2 surgeries) than patients receiving other treatment modalities. Total annual costs for chronic low back pain patients without neurological involvement were lower in TENS patients ($17,957 vs $17,986 for non-TENS), even when the cost of the device was taken into account.
Collapse
|
123
|
Gregory NS, Harris AL, Robinson CR, Dougherty PM, Fuchs PN, Sluka KA. An overview of animal models of pain: disease models and outcome measures. THE JOURNAL OF PAIN 2013; 14:1255-69. [PMID: 24035349 PMCID: PMC3818391 DOI: 10.1016/j.jpain.2013.06.008] [Citation(s) in RCA: 258] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2013] [Revised: 06/14/2013] [Accepted: 06/24/2013] [Indexed: 01/12/2023]
Abstract
UNLABELLED Pain is ultimately a perceptual phenomenon. It is built from information gathered by specialized pain receptors in tissue, modified by spinal and supraspinal mechanisms, and integrated into a discrete sensory experience with an emotional valence in the brain. Because of this, studying intact animals allows the multidimensional nature of pain to be examined. A number of animal models have been developed, reflecting observations that pain phenotypes are mediated by distinct mechanisms. Animal models of pain are designed to mimic distinct clinical diseases to better evaluate underlying mechanisms and potential treatments. Outcome measures are designed to measure multiple parts of the pain experience, including reflexive hyperalgesia measures, sensory and affective dimensions of pain, and impact of pain on function and quality of life. In this review, we discuss the common methods used for inducing each of the pain phenotypes related to clinical pain syndromes as well as the main behavioral tests for assessing pain in each model. PERSPECTIVE Understanding animal models and outcome measures in animals will assist in translating data from basic science to the clinic.
Collapse
Affiliation(s)
- Nicholas S Gregory
- Department of Physical Therapy and Rehabilitation Science, College of Medicine, University of Iowa, Iowa City, Iowa; Neuroscience Graduate Program, College of Medicine, University of Iowa, Iowa City, Iowa
| | | | | | | | | | | |
Collapse
|
124
|
|
125
|
On "what makes transcutaneous electrical nerve stimulation work?.." Sluka KA, Bjordal JM, Marchand S, Rakel BA. Phys Ther. 2013;93:1397-1402. Phys Ther 2013; 93:1426-7. [PMID: 24086069 DOI: 10.2522/ptj.2013.93.10.1426] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
126
|
Chesterton LS, Lewis AM, Sim J, Mallen CD, Mason EE, Hay EM, van der Windt DA. Transcutaneous electrical nerve stimulation as adjunct to primary care management for tennis elbow: pragmatic randomised controlled trial (TATE trial). BMJ 2013; 347:f5160. [PMID: 23999980 PMCID: PMC3759476 DOI: 10.1136/bmj.f5160] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/11/2013] [Indexed: 01/02/2023]
Abstract
OBJECTIVE To investigate the effectiveness of supplementing information and advice on analgesia and exercise from a general practitioner with transcutaneous electrical nerve stimulation (TENS) as a non-drug form of analgesia to reduce pain intensity in patients with tennis elbow. DESIGN Pragmatic randomised controlled trial in primary care. SETTING AND 38 general practices in the West Midlands, UK. PARTICIPANTS 241 adults consulting with a first or new (no consultation in previous six months) clinical diagnosis of tennis elbow. INTERVENTIONS Participants were randomly allocated to either primary care management alone, consisting of a consultation with a general practitioner followed by information and advice on exercises, or primary care management plus TENS to be used once a day for 45 minutes over six weeks (or until symptom resolution) for pain relief. OUTCOME MEASURES The primary outcome was self reported intensity of elbow pain (0-10 rating scale) at six weeks. Primary and secondary outcomes were measured at baseline and at six weeks, six months, and 12 months by postal questionnaire. Analysis was by intention to treat. RESULTS 121 participants were randomised to primary care management plus TENS and 120 to primary care management only (first episode, n=197 (82%); duration <1-3 months, n=138 (57%)). Adherence to exercise and TENS recommendations reported at six weeks was low; only 42 participants in the primary care management plus TENS group met a priori defined adherence criteria. Both intervention groups showed large improvements in pain and secondary outcomes, especially during the first six weeks of follow-up. However, no clinically or statistically significant differences were seen between groups at any follow-up timepoint. At the primary endpoint (six weeks), the between group difference in improvement of pain was -0.33 (95% confidence interval -0.96 to 0.31; P=0.31) in favour of the primary care management only group, with adjustment for age, sex, and baseline pain score. CONCLUSIONS This trial does not provide evidence for additional benefit of TENS as an adjunct to primary care management of tennis elbow. Poor adherence to interventions is evidence of the challenges of implementing self management treatment strategies in primary care. TRIAL REGISTRATION Current Controlled Trials ISRCTN87141084.
Collapse
Affiliation(s)
- Linda S Chesterton
- Arthritis Research UK Primary Care Centre, Keele University, Keele, Staffordshire ST5 5BG, UK.
| | | | | | | | | | | | | |
Collapse
|