151
|
Liu J, Zhang Y, Zhao Q, Lv T, Wu W, Cai N, Quan G, Yang W, Chen Y, Luo L, Shu H, Coatrieux JL. Deep iterative reconstruction estimation (DIRE): approximate iterative reconstruction estimation for low dose CT imaging. ACTA ACUST UNITED AC 2019; 64:135007. [DOI: 10.1088/1361-6560/ab18db] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
152
|
Anand R, Thittai AK. Compressed Sensing with Gaussian Sampling Kernel for Ultrasound Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1814-1829. [PMID: 30987910 DOI: 10.1016/j.ultrasmedbio.2019.02.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Revised: 02/08/2019] [Accepted: 02/15/2019] [Indexed: 06/09/2023]
Abstract
Recently, compressed sensing (CS) has been applied to ultrasound imaging for either data reduction or frame rate improvement. However, there are no detailed reports yet on strategies for lateral undersampling of channel data in conventional focused beamforming (CFB) and its recovery exploiting the CS approach. We propose a strategic lateral undersampling approach for channel data using the Gaussian sampling scheme and compare it with a direct extension of the often-used uniform undersampling reported for axial undersampling to the lateral direction and 2-D random sampling reported in the literature. As opposed to the reported 2-D random undersampling, we explore undersampling of channel data in the lateral direction by acquiring radiofrequency data from only a reduced number of chosen receive elements and subjecting these data to further undersampling in the axial direction. The effect of the sampling schemes on CS recovery was studied using data from simulations and experiments for various lateral and axial undersampling rates. The results suggest that CS-recovered data from the Gaussian distribution-based channel data subsampling yielded better recovery and contrast in comparison to those obtained from the often-used uniform distribution-based undersampling. Although 90% of the samples from the original data using the proposed sampling scheme were discarded, the contrast of the CS-recovered image was comparable to that of the reference image. Thus, CS with the proposed Gaussian sampling scheme for channel data subsampling not only reduces the data size significantly, but also strategically uses only a few active receive elements in the process; thus, it can provide an attractive option for the affordable point-of-care ultrasound system.
Collapse
Affiliation(s)
- Ramkumar Anand
- Biomedical Ultrasound Laboratory, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai, India
| | - Arun K Thittai
- Biomedical Ultrasound Laboratory, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai, India.
| |
Collapse
|
153
|
Gong K, Catana C, Qi J, Li Q. PET Image Reconstruction Using Deep Image Prior. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:1655-1665. [PMID: 30575530 PMCID: PMC6584077 DOI: 10.1109/tmi.2018.2888491] [Citation(s) in RCA: 121] [Impact Index Per Article: 20.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Recently, deep neural networks have been widely and successfully applied in computer vision tasks and have attracted growing interest in medical imaging. One barrier for the application of deep neural networks to medical imaging is the need for large amounts of prior training pairs, which is not always feasible in clinical practice. This is especially true for medical image reconstruction problems, where raw data are needed. Inspired by the deep image prior framework, in this paper, we proposed a personalized network training method where no prior training pairs are needed, but only the patient's own prior information. The network is updated during the iterative reconstruction process using the patient-specific prior information and measured data. We formulated the maximum-likelihood estimation as a constrained optimization problem and solved it using the alternating direction method of multipliers algorithm. Magnetic resonance imaging guided positron emission tomography reconstruction was employed as an example to demonstrate the effectiveness of the proposed framework. Quantification results based on simulation and real data show that the proposed reconstruction framework can outperform Gaussian post-smoothing and anatomically guided reconstructions using the kernel method or the neural-network penalty.
Collapse
|
154
|
Seghouane AK, Iqbal A, Abed-Meraim K. A Sequential Block-Structured Dictionary Learning Algorithm for Block Sparse Representations. IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING 2019; 5:228-239. [DOI: 10.1109/tci.2018.2884809] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
155
|
Cong W, Wang G, Yang Q, Li J, Hsieh J, Lai R. CT IMAGE RECONSTRUCTION ON A LOW DIMENSIONAL MANIFOLD. INVERSE PROBLEMS AND IMAGING (SPRINGFIELD, MO.) 2019; 13:449-460. [PMID: 36406139 PMCID: PMC9674026 DOI: 10.3934/ipi.2019022] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The patch manifold of a natural image has a low dimensional structure and accommodates rich structural information. Inspired by the recent work of the low-dimensional manifold model (LDMM), we apply the LDMM for regularizing X-ray computed tomography (CT) image reconstruction. This proposed method recovers detailed structural information of images, significantly enhancing spatial and contrast resolution of CT images. Both numerically simulated data and clinically experimental data are used to evaluate the proposed method. The comparative studies are also performed over the simultaneous algebraic reconstruction technique (SART) incorporated the total variation (TV) regularization to demonstrate the merits of the proposed method. Results indicate that the LDMM-based method enables a more accurate image reconstruction with high fidelity and contrast resolution.
Collapse
Affiliation(s)
- Wenxiang Cong
- Biomedical Imaging Center, Department of Biomedical Engineering Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | - Ge Wang
- Biomedical Imaging Center, Department of Biomedical Engineering Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | - Qingsong Yang
- Biomedical Imaging Center, Department of Biomedical Engineering Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | - Jia Li
- School of Mathematics Sun Yat-sen University, Guangzhou 510275, China
| | - Jiang Hsieh
- GE Healthcare Technologies, Waukesha, WI 53188, USA
| | - Rongjie Lai
- Department of Mathematical Sciences Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| |
Collapse
|
156
|
Seghouane AK, Iqbal A, Abed-Meraim K. Sequential Structured Dictionary Learning for Block Sparse Representations. ICASSP 2019 - 2019 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP) 2019. [DOI: 10.1109/icassp.2019.8683600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
157
|
Li Y, Sixou B, Burghard A, Peyrin F. Investigation of Semi-Coupled Dictionary Learning in 3-D Super Resolution HR-pQCT Imaging. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2019. [DOI: 10.1109/trpms.2018.2881488] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
158
|
Hu Z, Jiang C, Sun F, Zhang Q, Ge Y, Yang Y, Liu X, Zheng H, Liang D. Artifact correction in low‐dose dental
CT
imaging using Wasserstein generative adversarial networks. Med Phys 2019; 46:1686-1696. [DOI: 10.1002/mp.13415] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Revised: 01/16/2019] [Accepted: 01/22/2019] [Indexed: 11/08/2022] Open
Affiliation(s)
- Zhanli Hu
- Lauterbur Research Center for Biomedical Imaging Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
| | - Changhui Jiang
- Lauterbur Research Center for Biomedical Imaging Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
- Shenzhen College of Advanced Technology University of Chinese Academy of Sciences Shenzhen 518055 China
| | - Fengyi Sun
- Lauterbur Research Center for Biomedical Imaging Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
| | - Qiyang Zhang
- Lauterbur Research Center for Biomedical Imaging Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
| | - Yongshuai Ge
- Lauterbur Research Center for Biomedical Imaging Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
| | - Yongfeng Yang
- Lauterbur Research Center for Biomedical Imaging Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
| | - Xin Liu
- Lauterbur Research Center for Biomedical Imaging Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
| | - Hairong Zheng
- Lauterbur Research Center for Biomedical Imaging Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
| | - Dong Liang
- Lauterbur Research Center for Biomedical Imaging Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen 518055 China
| |
Collapse
|
159
|
Nam H, Guo M, Yu H, Lee K, Li R, Han B, Xing L, Lee R, Gao H. Tensor framelet based iterative image reconstruction algorithm for low-dose multislice helical CT. PLoS One 2019; 14:e0210410. [PMID: 30633760 PMCID: PMC6329516 DOI: 10.1371/journal.pone.0210410] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Accepted: 12/21/2018] [Indexed: 11/18/2022] Open
Abstract
In this study, we investigate the feasibility of improving the imaging quality for low-dose multislice helical computed tomography (CT) via iterative reconstruction with tensor framelet (TF) regularization. TF based algorithm is a high-order generalization of isotropic total variation regularization. It is implemented on a GPU platform for a fast parallel algorithm of X-ray forward band backward projections, with the flying focal spot into account. The solution algorithm for image reconstruction is based on the alternating direction method of multipliers or the so-called split Bregman method. The proposed method is validated using the experimental data from a Siemens SOMATOM Definition 64-slice helical CT scanner, in comparison with FDK, the Katsevich and the total variation (TV) algorithm. To test the algorithm performance with low-dose data, ACR and Rando phantoms were scanned with different dosages and the data was equally undersampled with various factors. The proposed method is robust for the low-dose data with 25% undersampling factor. Quantitative metrics have demonstrated that the proposed algorithm achieves superior results over other existing methods.
Collapse
Affiliation(s)
- Haewon Nam
- Department of Liberal Arts, Hongik University, Sejong, Republic of Korea
| | - Minghao Guo
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Hengyong Yu
- Department of Electrical and Computer Engineering, University of Massachusetts, Lowell, Massachusetts 01854, United States of America
| | - Keumsil Lee
- Department of Radiology, Stanford University, Stanford, California 94305, United States of America
| | - Ruijiang Li
- Department of Radiation Oncology, Stanford University, Stanford, California 94305, United States of America
| | - Bin Han
- Department of Radiation Oncology, Stanford University, Stanford, California 94305, United States of America
| | - Lei Xing
- Department of Radiation Oncology, Stanford University, Stanford, California 94305, United States of America
| | - Rena Lee
- Department of Radiation Oncology, Ewha Womans University, Seoul, Korea
| | - Hao Gao
- Department of Radiation Oncology, Emory University, Atlanta, GA 30322, United States of America
- * E-mail:
| |
Collapse
|
160
|
Gou J, Wu X, Dong H. Reduced iteration image reconstruction of incomplete projection CT using regularization strategy through Lp norm dictionary learning. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2019; 27:559-572. [PMID: 31177257 DOI: 10.3233/xst-180470] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
BACKGROUND For sparse and limited angle projection Computed Tomography (CT), the reconstructed image usually suffers from considerable artifacts due to undersampled data. OBJECTIVE To improve image reconstruction quality of sparse and limited angle projection CT, this study tested a novel reconstruction algorithm based on Dictionary Learning (DL) from sparse and limited projections. METHODS The study used signal sparse representation and feature extraction to render the DL technology, which is constrained by L2 and Lp norms, respectively. A Lp Norm Dictionary Learning term is suitable for regular term of objective function for CT image reconstruction. This is helpful for solving the objective function by combining algorithm of ART. Based on these features, the new algorithm of ART-DL-Lp is proposed for CT image reconstruction. The alternate solving strategy of the algorithm of "ART first, then adaptive DL" is provided in sequence. The impact on reconstruction results of ART-DL-Lp at different p values (0 < p < 1) is also considered. RESULTS For non-ideal projections with noise, the digital experiments show that ART-DL-Lp data were superior to those of ART, SART, and ART-DL-L2. Accordingly, the objective evaluation metrics for non-ideal situation of RMSE, MAE, PSNR, Residuals and SSIM are all better than those of contrasted three algorithms. The metrics curves of ART-DL-Lp algorithm are recorded as the best. In both incomplete projection situations, smaller p-value of ART-DL-Lp algorithm induces more close reconstructed images to the original form and better five objective evaluation metrics. CONCLUSIONS Overall, the reconstruction efficiency of the proposed ART-DL-Lp for CT imaging using the noisy incomplete projections outperforms ART, SART and ART-DL-L2 algorithms. For ART-DL-Lp algorithm, lower p-values result in better reconstruction performance.
Collapse
Affiliation(s)
- Junnian Gou
- School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, China
- Key Laboratory of Opto-technology and Intelligent Control, Ministry of Education, Lanzhou Jiaotong University, Lanzhou, China
- Rail Transit Electrical Automation Engineering Laboratory of Gansu Province, Lanzhou Jiaotong University, Lanzhou, China
| | - Xiaoyuan Wu
- School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, China
| | - Haiying Dong
- School of New Energy and Power Engineering, Lanzhou Jiaotong University, Lanzhou, China
| |
Collapse
|
161
|
Li K, Sang Z, Zhang X, Zhang M, Jiang C, Zhang Q, Ge Y, Liang D, Yang Y, Liu X, Zheng H, Hu Z. Few-view CT image reconstruction using improved total variation regularization. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2019; 27:739-753. [PMID: 31227684 DOI: 10.3233/xst-190506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
X-ray radiation is harmful to human health. Thus, obtaining a better reconstructed image with few projection view constraints is a major challenge in the computed tomography (CT) field to reduce radiation dose. In this study, we proposed and tested a new algorithm that combines penalized weighted least-squares using total generalized variation (PWLS-TGV) and dictionary learning (DL), named PWLS-TGV-DL to address this challenge. We first presented and tested this new algorithm and evaluated it through both data simulation and physical experiments. We then analyzed experimental data in terms of image qualitative and quantitative measures, such as the structural similarity index (SSIM) and the root mean square error (RMSE). The experiments and data analysis indicated that applying the new algorithm to CT data recovered images more efficiently and yielded better results than the traditional CT image reconstruction approaches.
Collapse
Affiliation(s)
- Kuai Li
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
- School of Information Engineering, Wuhan University of Technology, Wuhan, China
| | - Ziru Sang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xuezhu Zhang
- Department of Biomedical Engineering, University of California, Davis, CA, USA
| | - Mengxi Zhang
- Department of Biomedical Engineering, University of California, Davis, CA, USA
| | - Changhui Jiang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Qiyang Zhang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Yongshuai Ge
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Dong Liang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Yongfeng Yang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xin Liu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Hairong Zheng
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Zhanli Hu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| |
Collapse
|
162
|
Deng X, Zhao Y, Li H. Projection data smoothing through noise-level weighted total variation regularization for low-dose computed tomography. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2019; 27:537-557. [PMID: 31282470 DOI: 10.3233/xst-180469] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Reducing radiation dose while maintaining the quality of the reconstructed images is a major challenge in the computed tomography (CT) community. In light of the non-stationary Gaussian noise distribution, we developed a model that incorporates a noise-level weighted total variation (NWTV) regularization term for denoising the projection data. Contrary to the well-known edge-weighted total variation method, which aims for better edge preserving, the proposed NWTV tries to adapt the regularization with the spatially varying noise levels. Experiments on simulated data as well as the real imaging data suggest that the proposed NWTV regularization could achieve quite competitive results. For sinograms with sharp edges, the NWTV could do a better job at balancing noise reduction and edge preserving, such that noise is removed in a more uniform manner. Another conclusion from our experiments is that the well-recognized stair-casing artifacts of TV regularization play little role in the reconstructed images when the NWTV method is applied to low-dose CT imaging data.
Collapse
Affiliation(s)
- Xiaojuan Deng
- School of Mathematical Sciences, Capital Normal University, Beijing, China
- Beijing Advanced Innovation Center for Imaging Technology, Capital Normal University, Beijing, China
| | - Yunsong Zhao
- School of Mathematical Sciences, Capital Normal University, Beijing, China
- Beijing Advanced Innovation Center for Imaging Technology, Capital Normal University, Beijing, China
| | - Hongwei Li
- School of Mathematical Sciences, Capital Normal University, Beijing, China
- Beijing Advanced Innovation Center for Imaging Technology, Capital Normal University, Beijing, China
| |
Collapse
|
163
|
Generative Low-Dose CT Image Denoising. DEEP LEARNING AND CONVOLUTIONAL NEURAL NETWORKS FOR MEDICAL IMAGING AND CLINICAL INFORMATICS 2019. [DOI: 10.1007/978-3-030-13969-8_14] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
164
|
Zhao X, Jiang C, Zhang Q, Ge Y, Liang D, Liu X, Yang Y, Zheng H, Hu Z. Iterative image reconstruction for sparse-view CT via total variation regularization and dictionary learning. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2019; 27:573-590. [PMID: 31177258 DOI: 10.3233/xst-180477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Recently, low-dose computed tomography (CT) has become highly desirable due to the increasing attention paid to the potential risks of excessive radiation of the regular dose CT. However, ensuring image quality while reducing the radiation dose in the low-dose CT imaging is a major challenge. Compared to classical filtered back-projection (FBP) algorithms, statistical iterative reconstruction (SIR) methods for modeling measurement statistics and imaging geometry can significantly reduce the radiation dose, while maintaining the image quality in a variety of CT applications. To facilitate low-dose CT imaging, we in this study proposed an improved statistical iterative reconstruction scheme based on the penalized weighted least squares (PWLS) standard combined with total variation (TV) minimization and sparse dictionary learning (DL), which is named as a method of PWLS-TV-DL. To evaluate this PWLS-TV-DL method, we performed experiments on digital phantoms and physical phantoms, and analyzed the results in terms of image quality and calculation. The results show that the proposed method is better than the comparison methods, which indicates the potential of applying this PWLS-TV-DL method to reconstruct low-dose CT images.
Collapse
Affiliation(s)
- Xianyu Zhao
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
- School of Information Engineering, Wuhan University of Technology, Wuhan, China
| | - Changhui Jiang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Qiyang Zhang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Yongshuai Ge
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Dong Liang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xin Liu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Yongfeng Yang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Hairong Zheng
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Zhanli Hu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| |
Collapse
|
165
|
Development of Limited-Angle Iterative Reconstruction Algorithms with Context Encoder-Based Sinogram Completion for Micro-CT Applications. SENSORS 2018; 18:s18124458. [PMID: 30558381 PMCID: PMC6308519 DOI: 10.3390/s18124458] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2018] [Revised: 12/11/2018] [Accepted: 12/13/2018] [Indexed: 12/03/2022]
Abstract
Limited-angle iterative reconstruction (LAIR) reduces the radiation dose required for computed tomography (CT) imaging by decreasing the range of the projection angle. We developed an image-quality-based stopping-criteria method with a flexible and innovative instrument design that, when combined with LAIR, provides the image quality of a conventional CT system. This study describes the construction of different scan acquisition protocols for micro-CT system applications. Fully-sampled Feldkamp (FDK)-reconstructed images were used as references for comparison to assess the image quality produced by these tested protocols. The insufficient portions of a sinogram were inpainted by applying a context encoder (CE), a type of generative adversarial network, to the LAIR process. The context image was passed through an encoder to identify features that were connected to the decoder using a channel-wise fully-connected layer. Our results evidence the excellent performance of this novel approach. Even when we reduce the radiation dose by 1/4, the iterative-based LAIR improved the full-width half-maximum, contrast-to-noise and signal-to-noise ratios by 20% to 40% compared to a fully-sampled FDK-based reconstruction. Our data support that this CE-based sinogram completion method enhances the efficacy and efficiency of LAIR and that would allow feasibility of limited angle reconstruction.
Collapse
|
166
|
Zhang H, Gang GJ, Dang H, Stayman JW. Regularization Analysis and Design for Prior-Image-Based X-Ray CT Reconstruction. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:2675-2686. [PMID: 29994249 PMCID: PMC6295916 DOI: 10.1109/tmi.2018.2847250] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Prior-image-based reconstruction (PIBR) methods have demonstrated great potential for radiation dose reduction in computed tomography applications. PIBR methods take advantage of shared anatomical information between sequential scans by incorporating a patient-specific prior image into the reconstruction objective function, often as a form of regularization. However, one major challenge with PIBR methods is how to optimally determine the prior image regularization strength which balances anatomical information from the prior image with data fitting to the current measurements. Too little prior information yields limited improvements over traditional model-based iterative reconstruction, while too much prior information can force anatomical features from the prior image not supported by the measurement data, concealing true anatomical changes. In this paper, we develop quantitative measures of the bias associated with PIBR. This bias exhibits as a fractional reconstructed contrast of the difference between the prior image and current anatomy, which is quite different from traditional reconstruction biases that are typically quantified in terms of spatial resolution or artifacts. We have derived an analytical relationship between the PIBR bias and prior image regularization strength and illustrated how this relationship can be used as a predictive tool to prospectively determine prior image regularization strength to admit specific kinds of anatomical change in the reconstruction. Because bias is dependent on local statistics, we further generalized shift-variant prior image penalties that permit uniform (shift invariant) admission of anatomical changes across the imaging field of view. We validated the mathematical framework in phantom studies and compared bias predictions with estimates based on brute force exhaustive evaluation using numerous iterative reconstructions across regularization values. The experimental results demonstrate that the proposed analytical approach can predict the bias-regularization relationship accurately, allowing for prospective determination of the prior image regularization strength in PIBR. Thus, the proposed approach provides an important tool for controlling image quality of PIBR methods in a reliable, robust, and efficient fashion.
Collapse
Affiliation(s)
- Hao Zhang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205 USA (telephone: 410-955-1314, )
| | - Grace J. Gang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205 USA (telephone: 410-955-1314, )
| | - Hao Dang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205 USA (telephone: 410-955-1314, )
| | - J. Webster Stayman
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205 USA (telephone: 410-955-1314, )
| |
Collapse
|
167
|
Jia X, Liao Y, Zeng D, Zhang H, Zhang Y, He J, Bian Z, Wang Y, Tao X, Liang Z, Huang J, Ma J. Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image. Phys Med Biol 2018; 63:225020. [PMID: 30457116 PMCID: PMC6309620 DOI: 10.1088/1361-6560/aaebc9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
In some clinical applications, prior normal-dose CT (NdCT) images are available, and the valuable textures and structure features in them may be used to promote follow-up low-dose CT (LdCT) reconstruction. This study aims to learn texture information from the NdCT images and leverage it for follow-up LdCT image reconstruction to preserve textures and structure features. Specifically, the proposed reconstruction method first learns the texture information from those patches with similar structures in NdCT image, and the similar patches can be clustered by searching context features efficiently from the surroundings of the current patch. Then it utilizes redundant texture information from the similar patches as a priori knowledge to describe specific regions in the LdCT image. The advanced region-aware texture preserving prior is termed as 'RATP'. The main advantage of the PATP prior is that it can properly learn the texture features from available NdCT images and adaptively characterize the region-specific structures in the LdCT image. The experiments using patient data were performed to evaluate the performance of the proposed method. The proposed RATP method demonstrated superior performance in LdCT imaging compared to the filtered back projection (FBP) and statistical iterative reconstruction (SIR) methods using Gaussian regularization, Huber regularization and the original texture preserving regularization.
Collapse
Affiliation(s)
- Xiao Jia
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
- School of Software Engineering, Nanyang Normal University, Nanyang, Henan 473061, People’s Republic of China
- Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
| | - Yuting Liao
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
- Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
| | - Dong Zeng
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
- Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
| | - Hao Zhang
- Department of Radiation Oncology, Stanford University, Stanford, CA 94305, United States of America
| | - Yuanke Zhang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
- Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
| | - Ji He
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
- Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
| | - Zhaoying Bian
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
- Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
| | - Yongbo Wang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
- Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
| | - Xi Tao
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
- Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
| | - Zhengrong Liang
- Department of Radiology and Biomedical Engineering, State University of New York at Stony Brook, NY 11794, United States of America
| | - Jing Huang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
- Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
| | - Jianhua Ma
- School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
- Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangzhou, Guangdong 510515, People’s Republic of China
| |
Collapse
|
168
|
Bao P, Zhou J, Zhang Y. Group Sparsity based Sparse-Sampling CT Reconstruction. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:5097-5100. [PMID: 30441487 DOI: 10.1109/embc.2018.8513439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Classical total variation (TV) based iterative re-construction algorithms assume that the signal is piecewise smooth, which causes reconstruction results to suffer from the over-smoothing effect. To address this problem, this work presents a novel computed tomography (CT) reconstruction method for the sparse-sampling problem called the group- sparsity regularization-based simultaneous algebraic reconstruction technique (GSR-SART). Group-based sparse representation, which utilizes the concept of a group as the basic unit of sparse representation instead of a patch, is introduced as the image domain prior regularization term to eliminate the over-smoothing effect. By grouping the nonlocal patches into different clusters with similarity measured by Euclidean distance, the sparsity and nonlocal similarity in a single image are simultaneously explored. The split Bregman iteration algorithm is applied to obtain the numerical scheme. Experimental results demonstrate that our method both qualitatively and quantitatively outperforms several existing reconstruction methods, including filtered back projection, expectation maximization, SART, and TV-based projections onto convex sets.
Collapse
|
169
|
Wu W, Zhang Y, Wang Q, Liu F, Chen P, Yu H. Low-dose spectral CT reconstruction using image gradient ℓ 0-norm and tensor dictionary. APPLIED MATHEMATICAL MODELLING 2018; 63:538-557. [PMID: 32773921 PMCID: PMC7409840 DOI: 10.1016/j.apm.2018.07.006] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Spectral computed tomography (CT) has a great superiority in lesion detection, tissue characterization and material decomposition. To further extend its potential clinical applications, in this work, we propose an improved tensor dictionary learning method for low-dose spectral CT reconstruction with a constraint of image gradient ℓ 0-norm, which is named as ℓ 0TDL. The ℓ 0TDL method inherits the advantages of tensor dictionary learning (TDL) by employing the similarity of spectral CT images. On the other hand, by introducing the ℓ 0-norm constraint in gradient image domain, the proposed method emphasizes the spatial sparsity to overcome the weakness of TDL on preserving edge information. The split-bregman method is employed to solve the proposed method. Both numerical simulations and real mouse studies are perform to evaluate the proposed method. The results show that the proposed ℓ 0TDL method outperforms other competing methods, such as total variation (TV) minimization, TV with low rank (TV+LR), and TDL methods.
Collapse
Affiliation(s)
- Weiwen Wu
- Key Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, China
- Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA
| | - Yanbo Zhang
- Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA
| | - Qian Wang
- Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA
| | - Fenglin Liu
- Key Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, China
- Engineering Research Center of Industrial Computed Tomography Nondestructive Testing, Ministry of Education, Chongqing University, Chongqing 400044, China
- Corresponding author at: Key Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, China. (F. Liu)
| | - Peijun Chen
- Key Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, China
| | - Hengyong Yu
- Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA
| |
Collapse
|
170
|
Wang Y, Liao Y, Zhang Y, He J, Li S, Bian Z, Zhang H, Gao Y, Meng D, Zuo W, Zeng D, Ma J. Iterative quality enhancement via residual-artifact learning networks for low-dose CT. Phys Med Biol 2018; 63:215004. [PMID: 30265251 DOI: 10.1088/1361-6560/aae511] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Radiation exposure and the associated risk of cancer for patients in computed tomography (CT) scans have been major clinical concerns. The radiation exposure can be reduced effectively via lowering the x-ray tube current (mA). However, this strategy may lead to excessive noise and streak artifacts in the conventional filtered back-projection reconstructed images. To address this issue, some deep convolutional neural network (ConvNet) based approaches have been developed for low-dose CT imaging inspired by the recent development of machine learning. Nevertheless, some of the image textures reconstructed by the ConvNet could be corrupted by the severe streaks, especially in ultra-low-dose cases, which could be close to prostheses and hamper diagnosis. Therefore, in this work, we propose an iterative residual-artifact learning ConvNet (IRLNet) approach to improve the reconstruction performance over the ConvNet based approaches. Specifically, the proposed IRLNet estimates the high-frequency details within the noise and then removes them iteratively; after eliminating severe streaks in the low-dose CT images, the residual low-frequency details can be processed through the conventional network. Moreover, the proposed IRLNet scheme can be extended for robust handling of quantitative dual energy CT/cerebral perfusion CT imaging, and statistical iterative reconstruction. Real patient data are used to evaluate the proposed IRLNet, and the experimental results demonstrate that the proposed IRLNet approach outperforms the previous ConvNet based approaches in reducing the image noise and streak artifacts efficiently at the same time as preserving edge details well, suggesting that the proposed IRLNet approach can be used to improve the CT image quality, especially in ultra-low-dose cases.
Collapse
Affiliation(s)
- Yongbo Wang
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, People's Republic of China. Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Southern Medical University, Guangdong 510515, People's Republic of China. These authors contributed equally
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
171
|
Xie H, Niu T, Tang S, Yang X, Kadom N, Tang X. Content‐oriented sparse representation (
COSR
) for
CT
denoising with preservation of texture and edge. Med Phys 2018; 45:4942-4954. [DOI: 10.1002/mp.13189] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 08/17/2018] [Accepted: 09/05/2018] [Indexed: 11/10/2022] Open
Affiliation(s)
- Huiqiao Xie
- Department of Radiology and Imaging Sciences Emory University School of Medicine Atlanta GA USA
| | - Tianye Niu
- Sir Run Run Shaw Hospital Zhejiang University School of Medicine and Institute of Translational Medicine Zhejiang University Hangzhou Zhejiang China
| | - Shaojie Tang
- Xi'an University of Posts and Telecommunications Xi'an Shaanxi China
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute Emory University Atlanta GA USA
| | - Nadja Kadom
- Department of Radiology and Imaging Sciences Emory University School of Medicine Atlanta GA USA
| | - Xiangyang Tang
- Department of Radiology and Imaging Sciences Emory University School of Medicine Atlanta GA USA
| |
Collapse
|
172
|
Yi X, Babyn P. Sharpness-Aware Low-Dose CT Denoising Using Conditional Generative Adversarial Network. J Digit Imaging 2018; 31:655-669. [PMID: 29464432 PMCID: PMC6148809 DOI: 10.1007/s10278-018-0056-0] [Citation(s) in RCA: 121] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
Abstract
Low-dose computed tomography (LDCT) has offered tremendous benefits in radiation-restricted applications, but the quantum noise as resulted by the insufficient number of photons could potentially harm the diagnostic performance. Current image-based denoising methods tend to produce a blur effect on the final reconstructed results especially in high noise levels. In this paper, a deep learning-based approach was proposed to mitigate this problem. An adversarially trained network and a sharpness detection network were trained to guide the training process. Experiments on both simulated and real dataset show that the results of the proposed method have very small resolution loss and achieves better performance relative to state-of-the-art methods both quantitatively and visually.
Collapse
Affiliation(s)
- Xin Yi
- University of Saskatchewan, College of Medicine, Saskatoon, SK, Canada.
| | - Paul Babyn
- University of Saskatchewan, College of Medicine, Saskatoon, SK, Canada
| |
Collapse
|
173
|
Zhang H, Wang J, Zeng D, Tao X, Ma J. Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review. Med Phys 2018; 45:e886-e907. [PMID: 30098050 PMCID: PMC6181784 DOI: 10.1002/mp.13123] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2018] [Revised: 06/22/2018] [Accepted: 08/04/2018] [Indexed: 12/17/2022] Open
Abstract
Statistical image reconstruction (SIR) methods have shown potential to substantially improve the image quality of low-dose x-ray computed tomography (CT) as compared to the conventional filtered back-projection (FBP) method. According to the maximum a posteriori (MAP) estimation, the SIR methods are typically formulated by an objective function consisting of two terms: (a) a data-fidelity term that models imaging geometry and physical detection processes in projection data acquisition, and (b) a regularization term that reflects prior knowledge or expectations of the characteristics of the to-be-reconstructed image. SIR desires accurate system modeling of data acquisition, while the regularization term also has a strong influence on the quality of reconstructed images. A variety of regularization strategies have been proposed for SIR in the past decades, based on different assumptions, models, and prior knowledge. In this paper, we review the conceptual and mathematical bases of these regularization strategies and briefly illustrate their efficacies in SIR of low-dose CT.
Collapse
Affiliation(s)
- Hao Zhang
- Department of Radiation OncologyStanford UniversityStanfordCA94304USA
| | - Jing Wang
- Department of Radiation OncologyUT Southwestern Medical CenterDallasTX75390USA
| | - Dong Zeng
- School of Biomedical EngineeringSouthern Medical UniversityGuangzhou510515China
| | - Xi Tao
- School of Biomedical EngineeringSouthern Medical UniversityGuangzhou510515China
| | - Jianhua Ma
- School of Biomedical EngineeringSouthern Medical UniversityGuangzhou510515China
| |
Collapse
|
174
|
Mechlem K, Sellerer T, Ehn S, Munzel D, Braig E, Herzen J, Noel PB, Pfeiffer F. Spectral Angiography Material Decomposition Using an Empirical Forward Model and a Dictionary-Based Regularization. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:2298-2309. [PMID: 29993572 DOI: 10.1109/tmi.2018.2840841] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
By resolving the energy of the incident X-ray photons, spectral X-ray imaging with photon counting detectors offers additional material-specific information compared to conventional X-ray imaging. This additional information can be used to improve clinical diagnosis for various applications. However, spectral imaging still faces several challenges. Amplified noise and a reduced signal-to-noise ratio on the decomposed basis material images remain a major problem, especially for low-dose applications. Furthermore, it is challenging to construct an accurate model of the spectral measurement acquisition process. In this paper, we present a novel algorithm for projection-based material decomposition. It uses an empirical polynomial model that is tuned by calibration measurements. We combine this method with a statistical model of the measured photon counts and a dictionary-based joint regularization approach. We focused on spectral coronary angiography as a potential clinical application of projection-based material decomposition with photon counting detectors. Numerical and real experiments show that spectral angiography with realistic dose levels and gadolinium contrast agent concentrations are feasible using the proposed decomposition algorithm and currently available photon-counting detector technology.
Collapse
|
175
|
Bao P, Zhou J, Zhang Y. Few-view CT reconstruction with group-sparsity regularization. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2018; 34:e3101. [PMID: 29737620 DOI: 10.1002/cnm.3101] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Revised: 04/03/2018] [Accepted: 04/20/2018] [Indexed: 06/08/2023]
Abstract
Classical total variation-based iterative reconstruction algorithm is effective for the reconstruction of piecewise smooth image, but it causes oversmoothing effect for textured regions in the reconstructed image. To address this problem, this work presents a novel computed tomography reconstruction method for the few-view problem called the group-sparsity regularization-based simultaneous algebraic reconstruction technique (SART). Group-based sparse representation, which uses the concept of a group as the basic unit of sparse representation instead of a patch, is introduced as the image domain prior regularization term to eliminate the oversmoothing effect. By grouping the nonlocal patches into different clusters with similarity measured by Euclidean distance, the sparsity and nonlocal similarity in a single image are simultaneously explored. The split Bregman iteration algorithm is applied to obtain the numerical scheme. Experimental results demonstrate that our method both qualitatively and quantitatively outperforms several existing reconstruction methods, including filtered back projection, SART, total variation-based projections onto convex sets, and SART-based dictionary learning.
Collapse
Affiliation(s)
- Peng Bao
- College of Computer Science, Sichuan University, Chengdu 610065, China
| | - Jiliu Zhou
- College of Computer Science, Sichuan University, Chengdu 610065, China
| | - Yi Zhang
- College of Computer Science, Sichuan University, Chengdu 610065, China
| |
Collapse
|
176
|
Dynamic Tomographic Reconstruction of Deforming Volumes. MATERIALS 2018; 11:ma11081395. [PMID: 30096947 PMCID: PMC6119884 DOI: 10.3390/ma11081395] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/17/2018] [Revised: 08/03/2018] [Accepted: 08/06/2018] [Indexed: 12/20/2022]
Abstract
The motion of a sample while being scanned in a tomograph prevents its proper volume reconstruction. In the present study, a procedure is proposed that aims at estimating both the kinematics of the sample and its standard 3D imaging from a standard acquisition protocol (no more projection than for a rigid specimen). The proposed procedure is a staggered two-step algorithm where the volume is first reconstructed using a “Dynamic Reconstruction” technique, a variant of Algebraic Reconstruction Technique (ART) compensating for a “frozen” determination of the motion, followed by a Projection-based Digital Volume Correlation (P-DVC) algorithm that estimates the space/time displacement field, with a “frozen” microstructure and shape of the sample. Additionally, this procedure is combined with a multi-scale approach that is essential for a proper separation between motion and microstructure. A proof-of-concept of the validity and performance of this approach is proposed based on two virtual examples. The studied cases involve a small number of projections, large strains, up to 25%, and noise.
Collapse
|
177
|
Salehjahromi M, Zhang Y, Yu H. Iterative spectral CT reconstruction based on low rank and average-image-incorporated BM3D. Phys Med Biol 2018; 63:155021. [PMID: 30004028 PMCID: PMC6124507 DOI: 10.1088/1361-6560/aad356] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In a photon counting detector integrated spectral CT scanner, the received photons are counted in several energy channels to generate the corresponding projections. Since the projection in each energy channel is generated using part of the received photons, the reconstructed channel image suffers from severe noise. Therefore, image reconstruction in spectral CT is considered to be a big challenge. Because the inter-channel images are all from the same object but in different energy bins, there exists a strong correlation among these images. Moreover, it is suggested that there are similarities among various patches of CT images in the spatial domain. In this work, we propose average-image-incorporated block-matching and 3D (aiiBM3D) filtering along with low rank regularization for iterative spectral CT reconstruction. The aiiBM3D method is based on filtered 3D data arrays formed by similar 2D blocks using the mapped version of the average image obtained from linear regression. The reconstruction procedure consists of two main steps. First, the alternating direction method of multipliers is employed to solve the problem with low rank regularization where the goal is to exploit the correlation in inter-channel images. Second, our proposed BM3D-based algorithm is applied to all the channel images to make use of the redundant information in the spatial domain and inter-channel. The two steps repeat until the stopping criteria are satisfied. The proposed method is validated on numerically simulated and preclinical datasets. Our results confirm its high performance in terms of signal to noise ratio and structural preservation.
Collapse
Affiliation(s)
- Morteza Salehjahromi
- Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, USA 01854
| | - Yanbo Zhang
- Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, USA 01854
| | - Hengyong Yu
- Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, USA 01854
| |
Collapse
|
178
|
Zhang Y, Lu H, Rong J, Meng J, Shang J, Ren P, Zhang J. Adaptive non-local means on local principle neighborhood for noise/artifacts reduction in low-dose CT images. Med Phys 2018; 44:e230-e241. [PMID: 28901609 DOI: 10.1002/mp.12388] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Revised: 02/24/2017] [Accepted: 04/27/2017] [Indexed: 11/06/2022] Open
Abstract
PURPOSE Low-dose CT (LDCT) technique can reduce the x-ray radiation exposure to patients at the cost of degraded images with severe noise and artifacts. Non-local means (NLM) filtering has shown its potential in improving LDCT image quality. However, currently most NLM-based approaches employ a weighted average operation directly on all neighbor pixels with a fixed filtering parameter throughout the NLM filtering process, ignoring the non-stationary noise nature of LDCT images. In this paper, an adaptive NLM filtering scheme on local principle neighborhoods (PC-NLM) is proposed for structure-preserving noise/artifacts reduction in LDCT images. METHODS Instead of using neighboring patches directly, in the PC-NLM scheme, the principle component analysis (PCA) is first applied on local neighboring patches of the target patch to decompose the local patches into uncorrelated principle components (PCs), then a NLM filtering is used to regularize each PC of the target patch and finally the regularized components is transformed to get the target patch in image domain. Especially, in the NLM scheme, the filtering parameter is estimated adaptively from local noise level of the neighborhood as well as the signal-to-noise ratio (SNR) of the corresponding PC, which guarantees a "weaker" NLM filtering on PCs with higher SNR and a "stronger" filtering on PCs with lower SNR. The PC-NLM procedure is iteratively performed several times for better removal of the noise and artifacts, and an adaptive iteration strategy is developed to reduce the computational load by determining whether a patch should be processed or not in next round of the PC-NLM filtering. RESULTS The effectiveness of the presented PC-NLM algorithm is validated by experimental phantom studies and clinical studies. The results show that it can achieve promising gain over some state-of-the-art methods in terms of artifact suppression and structure preservation. CONCLUSIONS With the use of PCA on local neighborhoods to extract principal structural components, as well as adaptive NLM filtering on PCs of the target patch using filtering parameter estimated based on the local noise level and corresponding SNR, the proposed PC-NLM method shows its efficacy in preserving fine anatomical structures and suppressing noise/artifacts in LDCT images.
Collapse
Affiliation(s)
- Yuanke Zhang
- School of Biomedical Engineering, Fourth Military Medical University, Xi'an, Shaanxi, 710032, China.,School of Information Science and Engineering, Qufu Normal University, Rizhao, Shandong, 276826, China
| | - Hongbing Lu
- School of Biomedical Engineering, Fourth Military Medical University, Xi'an, Shaanxi, 710032, China
| | - Junyan Rong
- School of Biomedical Engineering, Fourth Military Medical University, Xi'an, Shaanxi, 710032, China
| | - Jing Meng
- School of Information Science and Engineering, Qufu Normal University, Rizhao, Shandong, 276826, China
| | - Junliang Shang
- School of Information Science and Engineering, Qufu Normal University, Rizhao, Shandong, 276826, China
| | - Pinghong Ren
- School of Information Science and Engineering, Qufu Normal University, Rizhao, Shandong, 276826, China
| | - Junying Zhang
- School of Computer Science and Technology, Xidian University, Xi'an, Shaanxi, 710071, China
| |
Collapse
|
179
|
Zhang H, Ma J, Wang J, Moore W, Liang Z. Assessment of prior image induced nonlocal means regularization for low-dose CT reconstruction: Change in anatomy. Med Phys 2018; 44:e264-e278. [PMID: 28901622 DOI: 10.1002/mp.12378] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Revised: 05/04/2017] [Accepted: 05/18/2017] [Indexed: 11/06/2022] Open
Abstract
PURPOSE Repeated computed tomography (CT) scans are prescribed for some clinical applications such as lung nodule surveillance. Several studies have demonstrated that incorporating a high-quality prior image into the reconstruction of subsequent low-dose CT (LDCT) acquisitions can either improve image quality or reduce data fidelity requirements. Our proposed previous normal-dose image induced nonlocal means (ndiNLM) regularization method for LDCT is an example of such a method. However, one major concern with prior image based methods is that they might produce false information when the prior image and the current LDCT image show different structures (for example, if a lung nodule emerges, grows, shrinks, or disappears over time). This study aims to assess the performance of the ndiNLM regularization method in situations with change in anatomy. METHOD We incorporated the ndiNLM regularization into the statistical image reconstruction (SIR) framework for reconstruction of subsequent LDCT images. Because of its patch-based search mechanism, a rough registration between the prior image and the current LDCT image is adequate for the SIR-ndiNLM method. We assessed the performance of the SIR-ndiNLM method in lung nodule surveillance for two different scenarios: (a) the nodule was not found in a baseline exam but appears in a follow-up LDCT scan; (b) the nodule was present in a baseline exam but disappears in a follow-up LDCT scan. We further investigated the effect of nodule size on the performance of the SIR-ndiNLM method. RESULTS We found that a relatively large search-window (e.g., 33 × 33) should be used for the SIR-ndiNLM method to account for misalignment between the prior image and the current LDCT image, and to ensure that enough similar patches can be found in the prior image. With proper selection of other parameters, experimental results with two patient datasets demonstrated that the SIR-ndiNLM method did not miss true nodules nor introduce false nodules in the lung nodule surveillance scenarios described above. We also found that the SIR-ndiNLM reconstruction shows improved image quality when the prior image is similar to the current LDCT image in anatomy. These gains in image quality might appear small upon visual inspection, but they can be detected using quantitative measures. Finally, the SIR-ndiNLM method also performed well in ultra-low-dose conditions and with different nodule sizes. CONCLUSIONS This study assessed the performance of the SIR-ndiNLM method in situations in which the prior image and the current LDCT image show substantial anatomical differences, specifically, changes in lung nodules. The experimental results demonstrate that the SIR-ndiNLM method does not introduce false lung nodules nor miss true nodules, which relieves the concern that this method might produce false information. However, there is insufficient evidence that these findings will hold true for all kinds of anatomical changes.
Collapse
Affiliation(s)
- Hao Zhang
- Department of Radiology, Stony Brook University, NY, 11794, USA.,Department of Biomedical Engineering, Stony Brook University, NY, 11794, USA
| | - Jianhua Ma
- Department of Biomedical Engineering, Southern Medical University, Guangdong, 510515, China
| | - Jing Wang
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, TX, 75390, USA
| | - William Moore
- Department of Radiology, Stony Brook University, NY, 11794, USA
| | - Zhengrong Liang
- Department of Radiology, Stony Brook University, NY, 11794, USA.,Department of Biomedical Engineering, Stony Brook University, NY, 11794, USA
| |
Collapse
|
180
|
Tang X, Krupinski EA, Xie H, Stillman AE. On the data acquisition, image reconstruction, cone beam artifacts, and their suppression in axial MDCT and CBCT - A review. Med Phys 2018; 45. [PMID: 30019342 DOI: 10.1002/mp.13095] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2017] [Revised: 06/12/2018] [Accepted: 07/05/2018] [Indexed: 12/12/2022] Open
Abstract
PURPOSE In the clinic, computed tomography (CT) has evolved into an essential modality for diagnostic imaging by multidetector row CT (MDCT) and image guided intervention by cone beam CT (CBCT). Recognizing the increasing importance of axial MDCT/CBCT in clinical and preclinical applications, and the existence of CB artifacts in MDCT/CBCT images, we provide a review of CB artifacts' root causes, rendering mechanisms and morphology, and possible solutions for elimination and/or reduction of the artifacts. METHODS By examining the null space in Radon and Fourier domain, the root cause of CB artifacts (i.e., data insufficiency) in axial MDCT/CBCT is analytically investigated, followed by a review of the data sufficiency conditions and the "circle +" source trajectories. The rendering mechanisms and morphology of CB artifacts in axial MDCT/CBCT and their special cases (e.g., half/short scan and full scan with latitudinally displaced detector) are then analyzed, followed by a survey of the potential solutions to suppress the artifacts. The phenomenon of imaged zone indention and its variation over FBP, BPF/DBPF, two-pass and iterative CB reconstruction algorithms and/or schemes are discussed in detail. RESULTS An interdomain examination of the null space provides an insightful understanding of the root cause of CB artifacts in axial MDCT/CBCT. The decomposition of CB artifacts rendering mechanisms facilitates understanding of the artifacts' behavior under different conditions and the potential solutions to suppress them. An inspection of the imaged zone intention phenomenon provides guidance on the design and implementation of CB image reconstruction algorithms and schemes for CB artifacts suppression in axial MDCT/CBCT. CONCLUSIONS With increasing importance of axial MDCT/CBCT in clinical and preclinical applications, this review article can update the community with in-depth information and clarification on the latest progress in dealing with CB artifacts and thus increase clinical/preclinical confidence.
Collapse
Affiliation(s)
- Xiangyang Tang
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Dr., C-5018, Atlanta, GA, 30322, USA
| | - Elizabeth A Krupinski
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Dr., C-5018, Atlanta, GA, 30322, USA
| | - Huiqiao Xie
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Dr., C-5018, Atlanta, GA, 30322, USA
| | - Arthur E Stillman
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Dr., C-5018, Atlanta, GA, 30322, USA
| |
Collapse
|
181
|
Hasan AM, Melli A, Wahid KA, Babyn P. Denoising Low-Dose CT Images Using Multiframe Blind Source Separation and Block Matching Filter. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2018. [DOI: 10.1109/trpms.2018.2810221] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
182
|
Guan H, Hagen CK, Olivo A, Anastasio MA. Subspace-based resolution-enhancing image reconstruction method for few-view differential phase-contrast tomography. J Med Imaging (Bellingham) 2018; 5:023501. [PMID: 29963577 DOI: 10.1117/1.jmi.5.2.023501] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Accepted: 05/31/2018] [Indexed: 01/08/2023] Open
Abstract
It is well known that properly designed image reconstruction methods can facilitate reductions in imaging doses and data-acquisition times in tomographic imaging. The ability to do so is particularly important for emerging modalities, such as differential x-ray phase-contrast tomography (D-XPCT), which are currently limited by these factors. An important application of D-XPCT is high-resolution imaging of biomedical samples. However, reconstructing high-resolution images from few-view tomographic measurements remains a challenging task due to the high-frequency information loss caused by data incompleteness. In this work, a subspace-based reconstruction strategy is proposed and investigated for use in few-view D-XPCT image reconstruction. By adopting a two-step approach, the proposed method can simultaneously recover high-frequency details within a certain region of interest while suppressing noise and/or artifacts globally. The proposed method is investigated by the use of few-view experimental data acquired by an edge-illumination D-XPCT scanner.
Collapse
Affiliation(s)
- Huifeng Guan
- Washington University in St. Louis, Department of Biomedical Engineering, St. Louis, Missouri, United States
| | - Charlotte Klara Hagen
- University College London, Department of Medical Physics and Biomedical Engineering, London, United Kingdom
| | - Alessandro Olivo
- University College London, Department of Medical Physics and Biomedical Engineering, London, United Kingdom
| | - Mark A Anastasio
- Washington University in St. Louis, Department of Biomedical Engineering, St. Louis, Missouri, United States
| |
Collapse
|
183
|
Shan H, Zhang Y, Yang Q, Kruger U, Kalra MK, Sun L, Cong W, Wang G. 3-D Convolutional Encoder-Decoder Network for Low-Dose CT via Transfer Learning From a 2-D Trained Network. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1522-1534. [PMID: 29870379 PMCID: PMC6022756 DOI: 10.1109/tmi.2018.2832217] [Citation(s) in RCA: 196] [Impact Index Per Article: 28.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Low-dose computed tomography (LDCT) has attracted major attention in the medical imaging field, since CT-associated X-ray radiation carries health risks for patients. The reduction of the CT radiation dose, however, compromises the signal-to-noise ratio, which affects image quality and diagnostic performance. Recently, deep-learning-based algorithms have achieved promising results in LDCT denoising, especially convolutional neural network (CNN) and generative adversarial network (GAN) architectures. This paper introduces a conveying path-based convolutional encoder-decoder (CPCE) network in 2-D and 3-D configurations within the GAN framework for LDCT denoising. A novel feature of this approach is that an initial 3-D CPCE denoising model can be directly obtained by extending a trained 2-D CNN, which is then fine-tuned to incorporate 3-D spatial information from adjacent slices. Based on the transfer learning from 2-D to 3-D, the 3-D network converges faster and achieves a better denoising performance when compared with a training from scratch. By comparing the CPCE network with recently published work based on the simulated Mayo data set and the real MGH data set, we demonstrate that the 3-D CPCE denoising model has a better performance in that it suppresses image noise and preserves subtle structures.
Collapse
Affiliation(s)
- Hongming Shan
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180 USA
| | - Yi Zhang
- Corresponding author. G. Wang ; Y. Zhang
| | - Qingsong Yang
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180 USA
| | - Uwe Kruger
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180 USA
| | - Mannudeep K. Kalra
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114 USA
| | - Ling Sun
- Huaxi MR Research Center (HMRRC), Department of Radiology, West China Hospital, Sichuan University, Chengdu, 610041 China
| | - Wenxiang Cong
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180 USA
| | - Ge Wang
- Corresponding author. G. Wang ; Y. Zhang
| |
Collapse
|
184
|
Zhang Z, Liang X, Dong X, Xie Y, Cao G. A Sparse-View CT Reconstruction Method Based on Combination of DenseNet and Deconvolution. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1407-1417. [PMID: 29870369 DOI: 10.1109/tmi.2018.2823338] [Citation(s) in RCA: 150] [Impact Index Per Article: 21.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Sparse-view computed tomography (CT) holds great promise for speeding up data acquisition and reducing radiation dose in CT scans. Recent advances in reconstruction algorithms for sparse-view CT, such as iterative reconstruction algorithms, obtained high-quality image while requiring advanced computing power. Lately, deep learning (DL) has been widely used in various applications and has obtained many remarkable outcomes. In this paper, we propose a new method for sparse-view CT reconstruction based on the DL approach. The method can be divided into two steps. First, filter backprojection (FBP) was used to reconstruct the CT image from sparsely sampled sinogram. Then, the FBP results were fed to a DL neural network, which is a DenseNet and deconvolution-based network (DD-Net). The DD-Net combines the advantages of DenseNet and deconvolution and applies shortcut connections to concatenate DenseNet and deconvolution to accelerate the training speed of the network; all of those operations can greatly increase the depth of network while enhancing the expression ability of the network. After the training, the proposed DD-Net achieved a competitive performance relative to the state-of-the-art methods in terms of streaking artifacts removal and structure preservation. Compared with the other state-of-the-art reconstruction methods, the DD-Net method can increase the structure similarity by up to 18% and reduce the root mean square error by up to 42%. These results indicate that DD-Net has great potential for sparse-view CT image reconstruction.
Collapse
|
185
|
Gupta H, Jin KH, Nguyen HQ, McCann MT, Unser M. CNN-Based Projected Gradient Descent for Consistent CT Image Reconstruction. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1440-1453. [PMID: 29870372 DOI: 10.1109/tmi.2018.2832656] [Citation(s) in RCA: 119] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
We present a new image reconstruction method that replaces the projector in a projected gradient descent (PGD) with a convolutional neural network (CNN). Recently, CNNs trained as image-to-image regressors have been successfully used to solve inverse problems in imaging. However, unlike existing iterative image reconstruction algorithms, these CNN-based approaches usually lack a feedback mechanism to enforce that the reconstructed image is consistent with the measurements. We propose a relaxed version of PGD wherein gradient descent enforces measurement consistency, while a CNN recursively projects the solution closer to the space of desired reconstruction images. We show that this algorithm is guaranteed to converge and, under certain conditions, converges to a local minimum of a non-convex inverse problem. Finally, we propose a simple scheme to train the CNN to act like a projector. Our experiments on sparse-view computed-tomography reconstruction show an improvement over total variation-based regularization, dictionary learning, and a state-of-the-art deep learning-based direct reconstruction technique.
Collapse
|
186
|
Yang Q, Yan P, Zhang Y, Yu H, Shi Y, Mou X, Kalra MK, Zhang Y, Sun L, Wang G. Low-Dose CT Image Denoising Using a Generative Adversarial Network With Wasserstein Distance and Perceptual Loss. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1348-1357. [PMID: 29870364 PMCID: PMC6021013 DOI: 10.1109/tmi.2018.2827462] [Citation(s) in RCA: 599] [Impact Index Per Article: 85.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
The continuous development and extensive use of computed tomography (CT) in medical practice has raised a public concern over the associated radiation dose to the patient. Reducing the radiation dose may lead to increased noise and artifacts, which can adversely affect the radiologists' judgment and confidence. Hence, advanced image reconstruction from low-dose CT data is needed to improve the diagnostic performance, which is a challenging problem due to its ill-posed nature. Over the past years, various low-dose CT methods have produced impressive results. However, most of the algorithms developed for this application, including the recently popularized deep learning techniques, aim for minimizing the mean-squared error (MSE) between a denoised CT image and the ground truth under generic penalties. Although the peak signal-to-noise ratio is improved, MSE- or weighted-MSE-based methods can compromise the visibility of important structural details after aggressive denoising. This paper introduces a new CT image denoising method based on the generative adversarial network (GAN) with Wasserstein distance and perceptual similarity. The Wasserstein distance is a key concept of the optimal transport theory and promises to improve the performance of GAN. The perceptual loss suppresses noise by comparing the perceptual features of a denoised output against those of the ground truth in an established feature space, while the GAN focuses more on migrating the data noise distribution from strong to weak statistically. Therefore, our proposed method transfers our knowledge of visual perception to the image denoising task and is capable of not only reducing the image noise level but also trying to keep the critical information at the same time. Promising results have been obtained in our experiments with clinical CT images.
Collapse
|
187
|
Zheng X, Ravishankar S, Long Y, Fessler JA. PWLS-ULTRA: An Efficient Clustering and Learning-Based Approach for Low-Dose 3D CT Image Reconstruction. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1498-1510. [PMID: 29870377 PMCID: PMC6034686 DOI: 10.1109/tmi.2018.2832007] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
The development of computed tomography (CT) image reconstruction methods that significantly reduce patient radiation exposure, while maintaining high image quality is an important area of research in low-dose CT imaging. We propose a new penalized weighted least squares (PWLS) reconstruction method that exploits regularization based on an efficient Union of Learned TRAnsforms (PWLS-ULTRA). The union of square transforms is pre-learned from numerous image patches extracted from a dataset of CT images or volumes. The proposed PWLS-based cost function is optimized by alternating between a CT image reconstruction step, and a sparse coding and clustering step. The CT image reconstruction step is accelerated by a relaxed linearized augmented Lagrangian method with ordered-subsets that reduces the number of forward and back projections. Simulations with 2-D and 3-D axial CT scans of the extended cardiac-torso phantom and 3-D helical chest and abdomen scans show that for both normal-dose and low-dose levels, the proposed method significantly improves the quality of reconstructed images compared to PWLS reconstruction with a nonadaptive edge-preserving regularizer. PWLS with regularization based on a union of learned transforms leads to better image reconstructions than using a single learned square transform. We also incorporate patch-based weights in PWLS-ULTRA that enhance image quality and help improve image resolution uniformity. The proposed approach achieves comparable or better image quality compared to learned overcomplete synthesis dictionaries, but importantly, is much faster (computationally more efficient).
Collapse
|
188
|
Abstract
We propose the Learned Primal-Dual algorithm for tomographic reconstruction. The algorithm accounts for a (possibly non-linear) forward operator in a deep neural network by unrolling a proximal primal-dual optimization method, but where the proximal operators have been replaced with convolutional neural networks. The algorithm is trained end-to-end, working directly from raw measured data and it does not depend on any initial reconstruction such as filtered back-projection (FBP). We compare performance of the proposed method on low dose computed tomography reconstruction against FBP, total variation (TV), and deep learning based post-processing of FBP. For the Shepp-Logan phantom we obtain >6 dB peak signal to noise ratio improvement against all compared methods. For human phantoms the corresponding improvement is 6.6 dB over TV and 2.2 dB over learned post-processing along with a substantial improvement in the structural similarity index. Finally, our algorithm involves only ten forward-back-projection computations, making the method feasible for time critical clinical applications.
Collapse
|
189
|
Chen B, Xiang K, Gong Z, Wang J, Tan S. Statistical Iterative CBCT Reconstruction Based on Neural Network. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1511-1521. [PMID: 29870378 PMCID: PMC6002810 DOI: 10.1109/tmi.2018.2829896] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Cone-beam computed tomography (CBCT) plays an important role in radiation therapy. Statistical iterative reconstruction (SIR) algorithms with specially designed penalty terms provide good performance for low-dose CBCT imaging. Among others, the total variation (TV) penalty is the current state-of-the-art in removing noises and preserving edges, but one of its well-known limitations is its staircase effect. Recently, various penalty terms with higher order differential operators were proposed to replace the TV penalty to avoid the staircase effect, at the cost of slightly blurring object edges. We developed a novel SIR algorithm using a neural network for CBCT reconstruction. We used a data-driven method to learn the "potential regularization term" rather than design a penalty term manually. This approach converts the problem of designing a penalty term in the traditional statistical iterative framework to designing and training a suitable neural network for CBCT reconstruction. We proposed using transfer learning to overcome the data deficiency problem and an iterative deblurring approach specially designed for the CBCT iterative reconstruction process during which the noise level and resolution of the reconstructed images may change. Through experiments conducted on two physical phantoms, two simulation digital phantoms, and patient data, we demonstrated the excellent performance of the proposed network-based SIR for CBCT reconstruction, both visually and quantitatively. Our proposed method can overcome the staircase effect, preserve both edges and regions with smooth intensity transition, and provide reconstruction results at high resolution and low noise level.
Collapse
|
190
|
Zhang Y, Yu H. Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1370-1381. [PMID: 29870366 PMCID: PMC5998663 DOI: 10.1109/tmi.2018.2823083] [Citation(s) in RCA: 207] [Impact Index Per Article: 29.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
In the presence of metal implants, metal artifacts are introduced to x-ray computed tomography CT images. Although a large number of metal artifact reduction (MAR) methods have been proposed in the past decades, MAR is still one of the major problems in clinical x-ray CT. In this paper, we develop a convolutional neural network (CNN)-based open MAR framework, which fuses the information from the original and corrected images to suppress artifacts. The proposed approach consists of two phases. In the CNN training phase, we build a database consisting of metal-free, metal-inserted and pre-corrected CT images, and image patches are extracted and used for CNN training. In the MAR phase, the uncorrected and pre-corrected images are used as the input of the trained CNN to generate a CNN image with reduced artifacts. To further reduce the remaining artifacts, water equivalent tissues in a CNN image are set to a uniform value to yield a CNN prior, whose forward projections are used to replace the metal-affected projections, followed by the FBP reconstruction. The effectiveness of the proposed method is validated on both simulated and real data. Experimental results demonstrate the superior MAR capability of the proposed method to its competitors in terms of artifact suppression and preservation of anatomical structures in the vicinity of metal implants.
Collapse
|
191
|
Kang E, Min J, Ye JC. A deep convolutional neural network using directional wavelets for low-dose X-ray CT reconstruction. Med Phys 2018; 44:e360-e375. [PMID: 29027238 DOI: 10.1002/mp.12344] [Citation(s) in RCA: 345] [Impact Index Per Article: 49.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2016] [Revised: 05/02/2017] [Accepted: 05/04/2017] [Indexed: 12/22/2022] Open
Abstract
PURPOSE Due to the potential risk of inducing cancer, radiation exposure by X-ray CT devices should be reduced for routine patient scanning. However, in low-dose X-ray CT, severe artifacts typically occur due to photon starvation, beam hardening, and other causes, all of which decrease the reliability of the diagnosis. Thus, a high-quality reconstruction method from low-dose X-ray CT data has become a major research topic in the CT community. Conventional model-based de-noising approaches are, however, computationally very expensive, and image-domain de-noising approaches cannot readily remove CT-specific noise patterns. To tackle these problems, we want to develop a new low-dose X-ray CT algorithm based on a deep-learning approach. METHOD We propose an algorithm which uses a deep convolutional neural network (CNN) which is applied to the wavelet transform coefficients of low-dose CT images. More specifically, using a directional wavelet transform to extract the directional component of artifacts and exploit the intra- and inter- band correlations, our deep network can effectively suppress CT-specific noise. In addition, our CNN is designed with a residual learning architecture for faster network training and better performance. RESULTS Experimental results confirm that the proposed algorithm effectively removes complex noise patterns from CT images derived from a reduced X-ray dose. In addition, we show that the wavelet-domain CNN is efficient when used to remove noise from low-dose CT compared to existing approaches. Our results were rigorously evaluated by several radiologists at the Mayo Clinic and won second place at the 2016 "Low-Dose CT Grand Challenge." CONCLUSIONS To the best of our knowledge, this work is the first deep-learning architecture for low-dose CT reconstruction which has been rigorously evaluated and proven to be effective. In addition, the proposed algorithm, in contrast to existing model-based iterative reconstruction (MBIR) methods, has considerable potential to benefit from large data sets. Therefore, we believe that the proposed algorithm opens a new direction in the area of low-dose CT research.
Collapse
Affiliation(s)
- Eunhee Kang
- Bio Imaging and Signal Processing Lab., Dept. of Bio and Brain Engineering, KAIST, Daejeon, Korea
| | - Junhong Min
- Bio Imaging and Signal Processing Lab., Dept. of Bio and Brain Engineering, KAIST, Daejeon, Korea
| | - Jong Chul Ye
- Bio Imaging and Signal Processing Lab., Dept. of Bio and Brain Engineering, KAIST, Daejeon, Korea
| |
Collapse
|
192
|
Cai A, Li L, Zheng Z, Wang L, Yan B. Block-matching sparsity regularization-based image reconstruction for low-dose computed tomography. Med Phys 2018; 45:2439-2452. [PMID: 29645279 DOI: 10.1002/mp.12911] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Revised: 03/26/2018] [Accepted: 03/29/2018] [Indexed: 01/04/2023] Open
Abstract
PURPOSE Low-dose computed tomography (CT) imaging has been widely explored because it can reduce the radiation risk to human bodies. This presents challenges in improving the image quality because low radiation dose with reduced tube current and pulse duration introduces severe noise. In this study, we investigate block-matching sparsity regularization (BMSR) and devise an optimization problem for low-dose image reconstruction. METHOD The objective function of the program is built by combining the sparse coding of BMSR and analysis error, which is subject to physical data measurement. A practical reconstruction algorithm using hard thresholding and projection-onto-convex-set for fast and stable performance is developed. An efficient scheme for the choices of regularization parameters is analyzed and designed. RESULTS In the experiments, the proposed method is compared with a conventional edge preservation method and adaptive dictionary-based iterative reconstruction. Experiments with clinical images and real CT data indicate that the obtained results show promising capabilities in noise suppression and edge preservation compared with the competing methods. CONCLUSIONS A block-matching-based reconstruction method for low-dose CT is proposed. Improvements in image quality are verified by quantitative metrics and visual comparisons, thereby indicating the potential of the proposed method for real-life applications.
Collapse
Affiliation(s)
- Ailong Cai
- National Digital Switching System Engineering & Technological Research Centre, Zhengzhou, Henan, 450002, China
| | - Lei Li
- National Digital Switching System Engineering & Technological Research Centre, Zhengzhou, Henan, 450002, China
| | - Zhizhong Zheng
- National Digital Switching System Engineering & Technological Research Centre, Zhengzhou, Henan, 450002, China
| | - Linyuan Wang
- National Digital Switching System Engineering & Technological Research Centre, Zhengzhou, Henan, 450002, China
| | - Bin Yan
- National Digital Switching System Engineering & Technological Research Centre, Zhengzhou, Henan, 450002, China
| |
Collapse
|
193
|
|
194
|
Cai A, Li L, Zheng Z, Zhang H, Wang L, Hu G, Yan B. Block matching sparsity regularization-based image reconstruction for incomplete projection data in computed tomography. Phys Med Biol 2018; 63:035045. [PMID: 29188791 DOI: 10.1088/1361-6560/aa9e63] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In medical imaging many conventional regularization methods, such as total variation or total generalized variation, impose strong prior assumptions which can only account for very limited classes of images. A more reasonable sparse representation frame for images is still badly needed. Visually understandable images contain meaningful patterns, and combinations or collections of these patterns can be utilized to form some sparse and redundant representations which promise to facilitate image reconstructions. In this work, we propose and study block matching sparsity regularization (BMSR) and devise an optimization program using BMSR for computed tomography (CT) image reconstruction for an incomplete projection set. The program is built as a constrained optimization, minimizing the L1-norm of the coefficients of the image in the transformed domain subject to data observation and positivity of the image itself. To solve the program efficiently, a practical method based on the proximal point algorithm is developed and analyzed. In order to accelerate the convergence rate, a practical strategy for tuning the BMSR parameter is proposed and applied. The experimental results for various settings, including real CT scanning, have verified the proposed reconstruction method showing promising capabilities over conventional regularization.
Collapse
Affiliation(s)
- Ailong Cai
- National Digital Switching System Engineering and Technological Research Centre, Zhengzhou 450002, Henan, People's Republic of China
| | | | | | | | | | | | | |
Collapse
|
195
|
Niu S, Yu G, Ma J, Wang J. Nonlocal low-rank and sparse matrix decomposition for spectral CT reconstruction. INVERSE PROBLEMS 2018; 34:024003. [PMID: 30294061 PMCID: PMC6168215 DOI: 10.1088/1361-6420/aa942c] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Spectral computed tomography (CT) has been a promising technique in research and clinic because of its ability to produce improved energy resolution images with narrow energy bins. However, the narrow energy bin image is often affected by serious quantum noise because of the limited number of photons used in the corresponding energy bin. To address this problem, we present an iterative reconstruction method for spectral CT using nonlocal low-rank and sparse matrix decomposition (NLSMD), which exploits the self-similarity of patches that are collected in multi-energy images. Specifically, each set of patches can be decomposed into a low-rank component and a sparse component, and the low-rank component represents the stationary background over different energy bins, while the sparse component represents the rest of different spectral features in individual energy bins. Subsequently, an effective alternating optimization algorithm was developed to minimize the associated objective function. To validate and evaluate the NLSMD method, qualitative and quantitative studies were conducted by using simulated and real spectral CT data. Experimental results show that the NLSMD method improves spectral CT images in terms of noise reduction, artifacts suppression and resolution preservation.
Collapse
Affiliation(s)
- Shanzhou Niu
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA
- School of Mathematics and Computer Science, Gannan Normal University, Ganzhou 341000, China
| | - Gaohang Yu
- School of Mathematics and Computer Science, Gannan Normal University, Ganzhou 341000, China
| | - Jianhua Ma
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China
| | - Jing Wang
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA
| |
Collapse
|
196
|
Wu J, Dai F, Hu G, Mou X. Low dose CT reconstruction via L1 norm dictionary learning using alternating minimization algorithm and balancing principle. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2018; 26:603-622. [PMID: 29689766 DOI: 10.3233/xst-17358] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Excessive radiation exposure in computed tomography (CT) scans increases the chance of developing cancer and has become a major clinical concern. Recently, statistical iterative reconstruction (SIR) with l0-norm dictionary learning regularization has been developed to reconstruct CT images from the low dose and few-view dataset in order to reduce radiation dose. Nonetheless, the sparse regularization term adopted in this approach is l0-norm, which cannot guarantee the global convergence of the proposed algorithm. To address this problem, in this study we introduced the l1-norm dictionary learning penalty into SIR framework for low dose CT image reconstruction, and developed an alternating minimization algorithm to minimize the associated objective function, which transforms CT image reconstruction problem into a sparse coding subproblem and an image updating subproblem. During the image updating process, an efficient model function approach based on balancing principle is applied to choose the regularization parameters. The proposed alternating minimization algorithm was evaluated first using real projection data of a sheep lung CT perfusion and then using numerical simulation based on sheep lung CT image and chest image. Both visual assessment and quantitative comparison using terms of root mean square error (RMSE) and structural similarity (SSIM) index demonstrated that the new image reconstruction algorithm yielded similar performance with l0-norm dictionary learning penalty and outperformed the conventional filtered backprojection (FBP) and total variation (TV) minimization algorithms.
Collapse
Affiliation(s)
- Junfeng Wu
- College of Science, Xi'an University of Technology, Xi'an, China
- The Key Laboratory of Computer Network and Information Integration, Southeast University, Ministry of Education, Nanjing, China
| | - Fang Dai
- College of Science, Xi'an University of Technology, Xi'an, China
| | - Gang Hu
- College of Science, Xi'an University of Technology, Xi'an, China
| | - Xuanqin Mou
- The Institute of Image processing and Pattern recognition, Xi'an Jiaotong University, Xi'an, China
| |
Collapse
|
197
|
Sunday DF, Kline RJ. Methodology for evaluating the information distribution in small angle scattering from periodic nanostructures. JOURNAL OF MICRO/NANOLITHOGRAPHY, MEMS, AND MOEMS : JM3 2018; 17:https://doi.org/10.1117/1.jmm.17.4.044002. [PMID: 33033553 PMCID: PMC7539628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Optimizing the extraction of information from x-ray measurements while minimizing exposure time is an important area of research in a variety of fields. The semiconductor industry is reaching a point where the traditional optical metrologies need to be augmented in order to better resolve the critical dimensions of structures with feature sizes below 10 nm. Critical dimension small angle x-ray scattering (CDSAXS) is one measurement technique that is capable of characterizing detailed features of periodic nanostructures. As currently implemented, the measurement utilizes the combined scattering from up to 60 different angles. Reducing the number of angles would dramatically improve the feasibility of CDSAXS for implementation in a fabrication setting, but currently there are no clear guidelines as to which angles provide the most information to minimize the uncertainty in the shape of the target structure while maximizing the throughput. In order to develop guidelines for optimizing the angle selection, simulation studies were conducted on a wide variety of structures with subsets of the full angular range to identify which angles minimized the overall shape uncertainty. Analyzing sets of two angle pairs (including all combinations between 0 deg and 60 deg) provides guidance on which angles best constrain the samples. For select samples, higher numbers of angles were included to explore the impact of additional information on the model uncertainty. In general, low angles (<3 deg) best contributed to minimizing the line-width uncertainty, while higher angles near high curvature regions of the scattering profile best constrained the height of the structure. The minimum uncertainty was generally achieved with combinations of the two. This simulation approach can be used to minimize the number of angles measured on real samples and significantly reduce the measurement time.
Collapse
|
198
|
You C, Yang Q, Shan H, Gjesteby L, Li G, Ju S, Zhang Z, Zhao Z, Zhang Y, Wenxiang C, Wang G. Structurally-sensitive Multi-scale Deep Neural Network for Low-Dose CT Denoising. IEEE ACCESS : PRACTICAL INNOVATIONS, OPEN SOLUTIONS 2018; 6:41839-41855. [PMID: 30906683 PMCID: PMC6426337 DOI: 10.1109/access.2018.2858196] [Citation(s) in RCA: 108] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Computed tomography (CT) is a popular medical imaging modality and enjoys wide clinical applications. At the same time, the x-ray radiation dose associated with CT scannings raises a public concern due to its potential risks to the patients. Over the past years, major efforts have been dedicated to the development of Low-Dose CT (LDCT) methods. However, the radiation dose reduction compromises the signal-to-noise ratio (SNR), leading to strong noise and artifacts that downgrade CT image quality. In this paper, we propose a novel 3D noise reduction method, called Structurally-sensitive Multi-scale Generative Adversarial Net (SMGAN), to improve the LDCT image quality. Specifically, we incorporate three-dimensional (3D) volumetric information to improve the image quality. Also, different loss functions for training denoising models are investigated. Experiments show that the proposed method can effectively preserve structural and textural information in reference to normal-dose CT (NDCT) images, and significantly suppress noise and artifacts. Qualitative visual assessments by three experienced radiologists demonstrate that the proposed method retrieves more information, and outperforms competing methods.
Collapse
Affiliation(s)
- Chenyu You
- Departments of Bioengineering and Electrical Engineering, Stanford University, Stanford, CA, 94305
| | - Qingsong Yang
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180
| | - Hongming Shan
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180
| | - Lars Gjesteby
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180
| | - Guang Li
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180
| | - Shenghong Ju
- Jiangsu Key Laboratory of Molecular and Functional Imaging, Department of Radiology, Zhongda Hospital, Medical School, Southeast University, Nanjing 210009, China
| | - Zhuiyang Zhang
- Department of Radiology, Wuxi No.2 People's Hospital,Wuxi, 214000, China
| | - Zhen Zhao
- Jiangsu Key Laboratory of Molecular and Functional Imaging, Department of Radiology, Zhongda Hospital, Medical School, Southeast University, Nanjing 210009, China
| | - Yi Zhang
- College of Computer Science, Sichuan University, Chengdu 610065, China
| | - Cong Wenxiang
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180
| | - Ge Wang
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180
| |
Collapse
|
199
|
Du W, Chen H, Wu Z, Sun H, Liao P, Zhang Y. Stacked competitive networks for noise reduction in low-dose CT. PLoS One 2017; 12:e0190069. [PMID: 29267360 PMCID: PMC5739486 DOI: 10.1371/journal.pone.0190069] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Accepted: 12/07/2017] [Indexed: 02/05/2023] Open
Abstract
Since absorption of X-ray radiation has the possibility of inducing cancerous, genetic and other diseases to patients, researches usually attempt to reduce the radiation dose. However, reduction of the radiation dose associated with CT scans will unavoidably increase the severity of noise and artifacts, which can seriously affect diagnostic confidence. Due to the outstanding performance of deep neural networks in image processing, in this paper, we proposed a Stacked Competitive Network (SCN) approach to noise reduction, which stacks several successive Competitive Blocks (CB). The carefully handcrafted design of the competitive blocks was inspired by the idea of multi-scale processing and improvement the network's capacity. Qualitative and quantitative evaluations demonstrate the competitive performance of the proposed method in noise suppression, structural preservation, and lesion detection.
Collapse
Affiliation(s)
- Wenchao Du
- School of Computer Science, Sichuan University, Chengdu, China
- National Key Laboratory of Fundamental Science on Synthetic Vision, Sichuan University, Chengdu, China
| | - Hu Chen
- School of Computer Science, Sichuan University, Chengdu, China
- National Key Laboratory of Fundamental Science on Synthetic Vision, Sichuan University, Chengdu, China
| | - Zhihong Wu
- School of Computer Science, Sichuan University, Chengdu, China
- National Key Laboratory of Fundamental Science on Synthetic Vision, Sichuan University, Chengdu, China
| | - Huaiqiang Sun
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Peixi Liao
- Department of Scientific Research and Education, The Sixth People’s Hospital of Chengdu, Chengdu, China
| | - Yi Zhang
- School of Computer Science, Sichuan University, Chengdu, China
| |
Collapse
|
200
|
Frame-Based CT Image Reconstruction via the Balanced Approach. JOURNAL OF HEALTHCARE ENGINEERING 2017; 2017:1417270. [PMID: 29201330 PMCID: PMC5672135 DOI: 10.1155/2017/1417270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/22/2017] [Accepted: 08/15/2017] [Indexed: 12/02/2022]
Abstract
Frame-based regularization method as one kind of sparsity representation method has been developed in recent years and has been proved to be an efficient method for CT image reconstruction. However, most of the developed CT image reconstruction methods are analysis-based frame methods. This paper proposes a novel frame-based balanced hybrid model with two sparse regularization terms for CT image reconstruction. We generalize the fast alternating direction method to solve the proposed model so that every subproblem can be easily solved. The numerical experiments suggest that the proposed hybrid balanced-based wavelet regularization scheme is efficient in terms of reducing the defined reconstruction root mean squared error and improving the signal to noise ratio in CT image reconstruction.
Collapse
|