251
|
Nair S, Nambiar M, Pope A, Parkes M, De Jong K, Hau R. Intraoperative fluoroscopy alone versus routine post-operative X-rays in identifying return to theatre after fracture fixation. ANZ J Surg 2021; 91:392-397. [PMID: 33538096 DOI: 10.1111/ans.16610] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 01/03/2021] [Accepted: 01/06/2021] [Indexed: 12/12/2022]
Abstract
BACKGROUND Post-operative imaging aims to assess fracture reduction and fixation with better resolution than intraoperative fluoroscopy (IF). However, this routine practice may increase costs and delay the discharge of patients. The aim of this study is to assess the role of post-operative imaging in identifying patients that require a return to theatre following the use of IF. METHODS A retrospective cohort study was conducted in a single health network comprising of two hospitals over 1 year. All fracture fixations that required IF were included. Patients who had post-operative imaging were identified and complications requiring a return to theatre were obtained. Non-trauma patients and those who did not have IF were excluded. RESULTS A total of 1319 patients had IF. Of these patients, 1131 patients had post-operative radiographs within 7 days of their operation. In total, 12 patients (1.1%) returned to theatre as a result of a finding identified in their post-operative imaging. The calculated number of X-rays required to be taken to identify a complication was 94. The main reasons identified for these cases to require a return to theatre despite having had IF included: (i) insufficient quality/views of IF, (ii) loss of position/new injury occurring in post-operative period and (iii) poor reduction/fixation demonstrated intraoperatively that was missed/accepted. CONCLUSION The use of post-operative radiographs can identify significant complications despite the use of IF in trauma patients. However, further consideration needs to be made regarding the benefits and costs of this practice in evaluating its clinical effectiveness.
Collapse
Affiliation(s)
- Sachin Nair
- Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Victoria, Australia.,Department of Orthopaedic Surgery, Box Hill Hospital, Melbourne, Victoria, Australia
| | - Mithun Nambiar
- Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Victoria, Australia.,Department of Orthopaedic Surgery, Box Hill Hospital, Melbourne, Victoria, Australia
| | - Alun Pope
- Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Victoria, Australia
| | - Muhajir Parkes
- Department of Radiology, Box Hill Hospital, Melbourne, Victoria, Australia
| | - Kenneth De Jong
- Department of Orthopaedic Surgery, Box Hill Hospital, Melbourne, Victoria, Australia
| | - Raphael Hau
- Department of Orthopaedic Surgery, Box Hill Hospital, Melbourne, Victoria, Australia.,Eastern Health Clinical School, Monash University, Melbourne, Victoria, Australia.,Northwest Clinical School, Northern Hospital, The University of Melbourne, Melbourne, Victoria, Australia
| |
Collapse
|
252
|
Weight-bearing CT in foot and ankle pathology. Orthop Traumatol Surg Res 2021; 107:102772. [PMID: 33321232 DOI: 10.1016/j.otsr.2020.102772] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2019] [Revised: 03/10/2020] [Accepted: 03/13/2020] [Indexed: 02/09/2023]
Abstract
Cone-beam scanners (CBCT) enable CT to be performed under weight-bearing - notably for the foot and ankle. The technology is not new: it has been used since 1996 in dental surgery, where it has come to replace panoramic X-ray. What is new is placing the scanner on the ground, so as to have 3D weight-bearing images, initially of the foot and ankle, and later for the knee and pelvis. This saves time, radiation and money. It is now increasingly used, but is unfortunately limited by not having specific national health insurance cover in France, and by the psychological reticence that goes with any technological breakthrough. A review of the topic is indispensable, as it is essential to become properly acquainted with this technique. To this end, we shall be addressing 5 questions. What biases does conventional radiography incur? Projecting a volume onto a plane incurs deformation, precluding true measurement. Conventional CT is therefore often associated with an increased dose of radiation. What is the impact of CBCT on radiation dose, costs and the care pathway? The conical beam turns around the limb (under weight-bearing if so desired) in less than a minute, making the radiation dose no greater than in standard X-ray. What does the literature have to say about CBCT, and what are the indications? CBCT is indicated in all foot and ankle pathologies, and indications now extend to the upper limb and the knee, and will soon include the pelvis. How are angles measured on this 3D technique? The recently developed concept of 3D biometry uses dedicated software to identify anatomic landmarks and automatically segment the bones, thereby enabling every kind of measurement. What further developments are to be expected? CBCT may become indispensable to lower-limb surgical planning. Artificial Intelligence will reveal novel diagnostic, prognostic and therapeutic solutions. LEVEL OF EVIDENCE: V; expert opinion.
Collapse
|
253
|
Harrison JD, Balonov M, Bochud F, Martin C, Menzel HG, Ortiz-Lopez P, Smith-Bindman R, Simmonds JR, Wakeford R. ICRP Publication 147: Use of Dose Quantities in Radiological Protection. Ann ICRP 2021; 50:9-82. [PMID: 33653178 DOI: 10.1177/0146645320911864] [Citation(s) in RCA: 69] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
|
254
|
Image quality of ultralow-dose chest CT using deep learning techniques: potential superiority of vendor-agnostic post-processing over vendor-specific techniques. Eur Radiol 2021; 31:5139-5147. [PMID: 33415436 DOI: 10.1007/s00330-020-07537-7] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 10/30/2020] [Accepted: 11/17/2020] [Indexed: 12/19/2022]
Abstract
OBJECTIVE To compare the image quality between the vendor-agnostic and vendor-specific algorithms on ultralow-dose chest CT. METHODS Vendor-agnostic deep learning post-processing model (DLM), vendor-specific deep learning image reconstruction (DLIR, high level), and adaptive statistical iterative reconstruction (ASiR, 70%) algorithms were employed. One hundred consecutive ultralow-dose noncontrast CT scans (CTDIvol; mean, 0.33 ± 0.056 mGy) were reconstructed with five algorithms: DLM-stnd (standard kernel), DLM-shrp (sharp kernel), DLIR, ASiR-stnd, and ASiR-shrp. Three thoracic radiologists blinded to the reconstruction algorithms reviewed five sets of 100 images and assessed subjective noise, spatial resolution, distortion artifact, and overall image quality. They selected the most preferred algorithm among five image sets for each case. Image noise and signal-to-noise ratio were measured. Edge-rise-distance was measured at a pulmonary vessel, i.e., the distance between two points where attenuation was 10% and 90% of maximal intravascular intensity. The skewness of attenuation was calculated in homogeneous areas. RESULTS DLM-stnd, followed by DLIR, showed the best subjective noise on both lung and mediastinal windows, while DLIR yielded the least measured noise (ps < .0001). Compared to DLM-stnd, DLIR showed inferior subjective spatial resolution on lung window and higher edge-rise-distance (ps < .0001). Additionally, DLIR showed the most frequent distortion artifacts and deviated skewness (ps < .0001). DLM-stnd scored the best overall image quality, followed by DLM-shrp and DLIR (mean score 3.89 ± 0.19, 3.68 ± 0.24, and 3.53 ± 0.33; ps < .001). Two among three readers preferred DLM-stnd on both windows. CONCLUSION Although DLIR provided the best quantitative noise profile, DLM-stnd showed the best overall image quality with fewer artifacts and was preferred by two among three readers. KEY POINTS • A vendor-agnostic deep learning post-processing algorithm applied to ultralow-dose chest CT exhibited the best image quality compared to vendor-specific deep learning algorithm and ASiR techniques. • Two out of three readers preferred a vendor-agnostic deep learning post-processing algorithm in comparison to vendor-specific deep learning algorithm and ASiR techniques. • A vendor-specific deep learning reconstruction algorithm yielded the least image noise, but showed significantly more frequent specific distortion artifacts and increased skewness of attenuation compared to a vendor-agnostic algorithm.
Collapse
|
255
|
Keles A, Keles MB, Keles A. COV19-CNNet and COV19-ResNet: Diagnostic Inference Engines for Early Detection of COVID-19. Cognit Comput 2021:1-11. [PMID: 33425046 PMCID: PMC7785922 DOI: 10.1007/s12559-020-09795-5] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Accepted: 11/16/2020] [Indexed: 12/23/2022]
Abstract
Chest CT is used in the COVID-19 diagnosis process as a significant complement to the reverse transcription polymerase chain reaction (RT-PCR) technique. However, it has several drawbacks, including long disinfection and ventilation times, excessive radiation effects, and high costs. While X-ray radiography is more useful for detecting COVID-19, it is insensitive to the early stages of the disease. We have developed inference engines that will turn X-ray machines into powerful diagnostic tools by using deep learning technology to detect COVID-19. We named these engines COV19-CNNet and COV19-ResNet. The former is based on convolutional neural network architecture; the latter is on residual neural network (ResNet) architecture. This research is a retrospective study. The database consists of 210 COVID-19, 350 viral pneumonia, and 350 normal (healthy) chest X-ray (CXR) images that were created using two different data sources. This study was focused on the problem of multi-class classification (COVID-19, viral pneumonia, and normal), which is a rather difficult task for the diagnosis of COVID-19. The classification accuracy levels for COV19-ResNet and COV19-CNNet were 97.61% and 94.28%, respectively. The inference engines were developed from scratch using new and special deep neural networks without pre-trained models, unlike other studies in the field. These powerful diagnostic engines allow for the early detection of COVID-19 as well as distinguish it from viral pneumonia with similar radiological appearances. Thus, they can help in fast recovery at the early stages, prevent the COVID-19 outbreak from spreading, and contribute to reducing pressure on health-care systems worldwide.
Collapse
Affiliation(s)
- Ayturk Keles
- Department of Computer Education and Instructional Technology, Faculty of Education, Agri Ibrahim Cecen University, 04100 Agri, Turkey
| | - Mustafa Berk Keles
- Department of Software Engineering, Faculty of Engineering, Istanbul Aydin University, 34295 Istanbul, Turkey
| | - Ali Keles
- Department of Computer Education and Instructional Technology, Faculty of Education, Agri Ibrahim Cecen University, 04100 Agri, Turkey
| |
Collapse
|
256
|
Kheir F, Thakore SR, Uribe Becerra JP, Tahboub M, Kamat R, Abdelghani R, Fernandez-Bussy S, Kaphle UR, Majid A. Cone-Beam Computed Tomography-Guided Electromagnetic Navigation for Peripheral Lung Nodules. Respiration 2021; 100:44-51. [PMID: 33401270 DOI: 10.1159/000510763] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Accepted: 08/09/2020] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Electromagnetic navigation bronchoscopy (ENB) is a minimally invasive technology for the diagnosis of peripheral pulmonary nodules. However, ENB is limited by the lack of real-time confirmation of various biopsy devices. Cone-beam computed tomography (CBCT) could increase diagnostic yield by allowing real-time confirmation to overcome the inherent divergence of nodule location. OBJECTIVES The aim of this study was to assess the diagnostic yield of ENB plus CBCT as compared with ENB alone for biopsy of peripheral lung nodules. METHOD We conducted a retrospective study of patients undergoing ENB before and after the implementation of CBCT. Data from 62 consecutive patients with lung nodules located in the outer two-thirds of the lung who underwent ENB and combined ENB-CBCT were collected. Radial endobronchial ultrasound was used during all procedures as well. Diagnostic yield was defined as the presence of malignancy or benign histological findings that lead to a specific diagnosis. RESULTS Thirty-one patients had ENB-CBCT, and 31 patients had only ENB for peripheral lung lesions. The median size of the lesion for the ENB-CBCT group was 16 (interquartile range (IQR) 12.6-25.5) mm as compared to 21.5 (IQR 16-27) mm in the ENB group (p = 0.2). In the univariate analysis, the diagnostic yield of ENB-CBCT was 74.2% and ENB 51.6% (p = 0.05). Following multivariate regression analysis adjusting for the size of the lesion, distance from the pleura, and presence of bronchus sign, the odds ratio for the diagnostic yield was 3.4 (95% CI 1.03-11.26, p = 0.04) in the ENB-CBCT group as compared with ENB alone. The median time for the procedure was shorter in patients in the ENB-CBCT group (74 min) than in those in the ENB group (90 min) (p = 0.02). The rate of adverse events was similar in both groups (6.5%, p = 0.7). CONCLUSIONS The use of CBCT might increase the diagnostic yield in ENB-guided peripheral lung nodule biopsies. Future randomized clinical trials are needed to confirm such findings.
Collapse
Affiliation(s)
- Fayez Kheir
- Division of Pulmonary Diseases, Critical Care and Environmental Medicine, Tulane University Health Sciences Center, New Orleans, Louisiana, USA.,Division of Thoracic Surgery and Interventional Pulmonology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Sanket R Thakore
- Division of Pulmonary Diseases, Critical Care and Environmental Medicine, Tulane University Health Sciences Center, New Orleans, Louisiana, USA.,Division of Interventional Pulmonary, Department of Pulmonary, Critical Care and Sleep Medicine, Yale University, New Haven, Connecticut, USA
| | - Juan Pablo Uribe Becerra
- Division of Thoracic Surgery and Interventional Pulmonology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Mohammad Tahboub
- Division of Pulmonary Diseases, Critical Care and Environmental Medicine, Tulane University Health Sciences Center, New Orleans, Louisiana, USA
| | - Rahul Kamat
- Division of Pulmonary Diseases, Critical Care and Environmental Medicine, Tulane University Health Sciences Center, New Orleans, Louisiana, USA
| | - Ramsy Abdelghani
- Division of Pulmonary Diseases, Critical Care and Environmental Medicine, Tulane University Health Sciences Center, New Orleans, Louisiana, USA.,Division of Thoracic Surgery and Interventional Pulmonology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | | | - Upendra R Kaphle
- Division of Pulmonary and Critical Care, Kaiser Permanente Roseville and Sacramento Medical Center, Roseville, California, USA
| | - Adnan Majid
- Division of Thoracic Surgery and Interventional Pulmonology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA,
| |
Collapse
|
257
|
Radiation dose from medical imaging in end stage renal disease patients: a Nationwide Italian Survey. J Nephrol 2021; 34:791-799. [PMID: 33387337 DOI: 10.1007/s40620-020-00911-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Accepted: 11/11/2020] [Indexed: 12/14/2022]
Abstract
BACKGROUND AND OBJECTIVES End stage renal disease (ESRD) patients are exposed to the risk of ionizing radiation during repeated imaging studies. The variability in diagnostic imaging policies and the accompanying radiation doses across various renal units is still unknown. We studied this variability at the centre level and quantified the associated radiation doses at the patient level. METHODS Fourteen Italian nephrology departments enrolled 739 patients on haemodialysis and 486 kidney transplant patients. The details of the radiological procedures performed over one year were recorded. The effective doses and organ doses of radiation were estimated for each patient using standardized methods to convert exposure parameters into effective and organ doses RESULTS: Computed tomography (CT) was the major contributor (> 77%) to ionizing radiation exposure. Among the haemodialysis and kidney transplant patients, 15% and 6% were in the high (≥ 20 mSv per year) radiation dose groups, respectively. In haemodialysis patients, the most exposed organs were the liver (16 mSv), the kidney (15 mSv) and the stomach (14 mSv), while the uterus (6.2 mSv), the lung (5.7 mSv) and the liver (5.5 mSv) were the most exposed in kidney transplant patients. The average cumulative effective dose (CED) of ionizing radiation among centres in this study was highly variable both in haemodialysis (from 6.4 to 18.8 mSv per patient-year; p = 0.018) and even more so in kidney transplant (from 0.6 to 13.7 mSv per patient-year; p = 0.002) patients. CONCLUSIONS Radiation exposure attributable to medical imaging is high in distinct subgroups of haemodialysis and transplant patients. Furthermore, there is high inter-centre variability in radiation exposure, suggesting that nephrology units have substantially different clinical policies for the application of diagnostic imaging studies.
Collapse
|
258
|
Edam A, Sulieman A, Tamam N, Abuelhaia E, Salih I, Sam A, Yousef M, Alkhorayef M, Bradley D. Current Sudan protective practice in diagnostic nuclear medicine and patient dose. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2020.108997] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
259
|
Ali WM, Sulieman A, Salah H, Almohammed H, Alkhorayef M, Bradley D. Short-term retention of 99mTc activity in bone scintigraphy. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2020.108907] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
260
|
Rawashdeh MA, Saade C. Radiation dose reduction considerations and imaging patterns of ground glass opacities in coronavirus: risk of over exposure in computed tomography. LA RADIOLOGIA MEDICA 2021; 126:380-387. [PMID: 32897493 PMCID: PMC7477737 DOI: 10.1007/s11547-020-01271-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 08/23/2020] [Indexed: 01/07/2023]
Abstract
This article aims to summarize the available data on the severe acute respiratory syndrome coronavirus 2 (SAR-CoV-2) imaging patterns as well as reducing radiation dose exposure in chest computed tomography (CT) protocols. First, the general aspects of radiation dose in CT and radiation risk are discussed, followed by the effect of changing parameters on image quality. This article attempts to highlight some of the common chest CT signs that radiologists and emergency physicians are likely to encounter. With the increasing trend of using chest CT scans as an imaging tool to diagnose and monitor SAR-CoV-2, we emphasize that pattern recognition is the key, and this pictorial essay should serve as a guide to help establish correct diagnosis coupled with correct scanner parameters to reduce radiation dose without affecting imaging quality in this tragic pandemic the world is facing.
Collapse
Affiliation(s)
- Mohammad Ahmmad Rawashdeh
- grid.37553.370000 0001 0097 5797Department of Allied Medical Sciences, Jordan University of Science and Technology, P.O.Box 3030, Irbid, 22110 Jordan
| | - Charbel Saade
- grid.411654.30000 0004 0581 3406Diagnostic Radiology Department, American University of Beirut Medical Center, P.O.Box 11-0236, Riad El-Solh, Beirut, 1107 2020 Lebanon
| |
Collapse
|
261
|
Loughenbury PR, Gentles SL, Murphy EJ, Tomlinson JE, Borse VH, Dunsmuir RA, Gummerson NW, Millner PA, Rao AS, Rowbotham E, Khan AL. Estimated cumulative X-ray exposure and additional cancer risk during the evaluation and treatment of scoliosis in children and young people requiring surgery. Spine Deform 2021; 9:949-954. [PMID: 33660241 PMCID: PMC8270816 DOI: 10.1007/s43390-021-00314-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Accepted: 02/14/2021] [Indexed: 10/29/2022]
Abstract
INTRODUCTION Clinicians and patients must weigh the benefits of radiological imaging against the risks of radiation exposure in the diagnosis and treatment of scoliosis. This report aims to estimate the cumulative absorbed and equivalent dose of radiation in patients undergoing surgical treatment for scoliosis, and to present this as an estimated risk of cancer compared to background radiation levels. METHODS Retrospective review of estimated absorbed dose on the Computerised Radiology Information System (CRIS®). Patients undergoing surgical correction of scoliosis (age ≤ 25) from August 2010 to August 2015 investigated. Estimated absorbed dose [milligrays (mGy)] recorded. Pedicle screws inserted using image intensification. Equivalent dose [millisieverts (mSv)] and additional cancer risk calculated from the National Research Council document 'Health risks from exposure to low levels of ionising radiation' (2006). RESULTS 271 patients identified. Mean age 15 (range 2-25). Mean total absorbed dose 2136 mGy [standard deviation (SD) 1700 mGy]. Mean number of plain spine radiographs was 8 (SD 3) with total 1884 mGy exposure (SD 1609 mGy). Additional dose provided by CT (mean 0.17 episodes), plain chest and abdominal radiographs and image intensification. Mean number of image intensification episodes was 1.1 with mean estimated exposure 180 mGy (SD 238 mGy). Image intensification accounted for 8% of the estimated absorbed dose during treatment. Estimated mean effective dose delivered was 20.952 mSv equating to an additional cancer risk of 0.27-0.45%. CONCLUSION Additional cancer risk from cumulative imaging is small and equivalent to approximately 8 years of natural background radiation. Use of image intensification for pedicle screw insertion is a minor contribution (8%) to the total patient dose.
Collapse
Affiliation(s)
- P. R. Loughenbury
- grid.415967.80000 0000 9965 1030Centre for Neurosciences, Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds, LS1 3EX UK
| | - S. L. Gentles
- grid.415967.80000 0000 9965 1030Centre for Neurosciences, Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds, LS1 3EX UK
| | - E. J. Murphy
- grid.415967.80000 0000 9965 1030Centre for Neurosciences, Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds, LS1 3EX UK
| | - J. E. Tomlinson
- grid.415967.80000 0000 9965 1030Centre for Neurosciences, Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds, LS1 3EX UK
| | - V. H. Borse
- grid.415967.80000 0000 9965 1030Centre for Neurosciences, Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds, LS1 3EX UK
| | - R. A. Dunsmuir
- grid.415967.80000 0000 9965 1030Centre for Neurosciences, Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds, LS1 3EX UK
| | - N. W. Gummerson
- grid.415967.80000 0000 9965 1030Centre for Neurosciences, Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds, LS1 3EX UK
| | - P. A. Millner
- grid.415967.80000 0000 9965 1030Centre for Neurosciences, Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds, LS1 3EX UK
| | - A. S. Rao
- grid.415967.80000 0000 9965 1030Centre for Neurosciences, Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds, LS1 3EX UK
| | - E. Rowbotham
- grid.415967.80000 0000 9965 1030Centre for Neurosciences, Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds, LS1 3EX UK
| | - A. L. Khan
- grid.415967.80000 0000 9965 1030Centre for Neurosciences, Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds, LS1 3EX UK
| |
Collapse
|
262
|
Longhitano A, Alipour R, Khot A, Bajel A, Antippa P, Slavin M, Thursky K. The role of 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG PET/CT) in assessment of complex invasive fungal disease and opportunistic co-infections in patients with acute leukemia prior to allogeneic hematopoietic cell transplant. Transpl Infect Dis 2020; 23:e13547. [PMID: 33338319 DOI: 10.1111/tid.13547] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 12/03/2020] [Accepted: 12/06/2020] [Indexed: 12/20/2022]
Abstract
INTRODUCTION Individuals diagnosed with acute lymphoid and myeloid malignancies are at significant risk of invasive fungal and bacterial infections secondary to their marked immunocompromised states with a significant high risk of mortality. The role of metabolic imaging with 18F-Fluorodeoxyglucose (FDG) Positron Emission Tomography/Computed Tomography (PET/CT) has been increasingly recognized in optimizing the diagnosis of invasive infection, monitoring the response to therapy and guiding the duration of antimicrobial therapy or need to escalate to surgical intervention. METHODS Two distinct cases of pulmonary co-infection of rare fungal and bacterial pathogens are explored in severely immunocompromised individuals where FDG PET/CT aided both patients to make a full recovery and transition to HCT. The first case explores mixed Scedosporium apiospermum and Rhizomucor pulmonary infection on a background of T cell/myeloid mixed phenotype acute leukemia ultimately warranting long-term antifungal therapy and lobectomy prior to HCT. The second case explores Fusarium and Nocardia pulmonary infection on a background of relapsed AML also warranting surgical resection with lobectomy and long-term antimicrobials prior to transition to HCT. DISCUSSION The cases highlight the utility of FDG PET/CT to support the diagnosis of infections, including the presence or absence of disseminated infection, and to provide highly sensitive monitoring of the infection over time. FDG PET/CT played a key role in directing therapy duration decisions and prompted the necessity for surgical intervention. Ultimately, the use of FDG PET/CT allowed for a successful transition to HCT highlighting its value in this clinical setting. CONCLUSION FDG PET/CT has an emerging role in the diagnostic and monitoring pathway for complex infections in high-risk immunocompromised patients.
Collapse
Affiliation(s)
- Anthony Longhitano
- Department of Infectious Diseases, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia
| | - Ramin Alipour
- Sir Peter MacCallum Department of Oncology, University of Melbourne Parkville, Melbourne, Vic., Australia.,Department of Molecular Imaging and Therapeutic Nuclear Medicine, Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia
| | - Amit Khot
- Clinical Haematology, Peter MacCallum Cancer Centre and Royal Melbourne Hospital, Melbourne, Vic., Australia
| | - Ashish Bajel
- Clinical Haematology, Peter MacCallum Cancer Centre and Royal Melbourne Hospital, Melbourne, Vic., Australia
| | - Phillip Antippa
- Department of Cardiothoracic Surgery, The Royal Melbourne Hospital, Melbourne, Vic., Australia.,Lung Cancer Service, Victorian Comprehensive Cancer Centre, Melbourne, Vic., Australia
| | - Monica Slavin
- Department of Infectious Diseases, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia.,Sir Peter MacCallum Department of Oncology, University of Melbourne Parkville, Melbourne, Vic., Australia.,National Centre for Infection in Cancer, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia
| | - Karin Thursky
- Department of Infectious Diseases, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia.,National Centre for Antimicrobial Stewardship (NCAS), The Peter Doherty Institute for Infection and Immunity, Melbourne, Vic., Australia.,Department of Medicine, University of Melbourne, Parkville, Vic., Australia
| |
Collapse
|
263
|
Scoring Osteoarthritis Reliably in Large Joints and the Spine Using Whole-Body CT: OsteoArthritis Computed Tomography-Score (OACT-Score). J Pers Med 2020; 11:jpm11010005. [PMID: 33375114 PMCID: PMC7822205 DOI: 10.3390/jpm11010005] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 12/18/2020] [Accepted: 12/18/2020] [Indexed: 01/02/2023] Open
Abstract
A standardized method to assess structural osteoarthritis (OA) burden thorough the body lacks from literature. Such a method can be valuable in developing personalized treatments for OA. We developed a reliable scoring system to evaluate OA in large joints and the spine-the OsteoArthritis Computed Tomography (OACT) score, using a convenience sample of 197 whole-body low-dose non-contrast CTs. An atlas, containing example images as reference points for training and scoring, are presented. Each joint was graded between 0-3. The total OA burden was calculated by summing scores of individual joints. Intra- and inter-observer reliability was tested 25 randomly selected scans (N = 600 joints). Intra-observer reliability and inter-observer reliability between three observers was assessed using intraclass correlation coefficient (ICC) and square-weighted kappa statistics. The square-weighted kappa for intra-observer reliability for OACT-score at joint-level ranged from 0.79 to 0.95; the ICC for the total OA grade was 0.97 (95%-CI, 0.94 to 0.99). Square-weighted kappa for interobserver reliability ranged from 0.48 to 0.95; the ICC for the total OA grade was 0.95 (95%-CI, 0.90 to 0.98). The OACT score, a new reproducible CT-based grading system reflecting OA burden in large joints and the spine, has a satisfactory reproducibility. The atlas can be used for research purposes, training, educational purposes and systemic grading of OA on CT-scans.
Collapse
|
264
|
Kim M, Kim JS, Lee C, Kang BK. Detection of pneumoperitoneum in the abdominal radiograph images using artificial neural networks. Eur J Radiol Open 2020; 8:100316. [PMID: 33385018 PMCID: PMC7770533 DOI: 10.1016/j.ejro.2020.100316] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Revised: 12/15/2020] [Accepted: 12/16/2020] [Indexed: 12/15/2022] Open
Abstract
The purpose of this study was to assess the diagnostic performance of artificial neural networks (ANNs) to detect pneumoperitoneum in abdominal radiographs for the first time. This approach applied a novel deep-learning algorithm, a simple ANN training process without employing CNN, and also used ResNet-50, for comparison. By applying ResNet-50 to abdominal radiographs, we obtained an area under the ROC curve (AUC) of 0.916 and an accuracy of 85.0 % with a sensitivity of 85.7 % and a predictive value of the negative tests (NPV) of 91.7 %. Compared with CNN, our novel approach used extremely small ANN structures and a simple ANN training process. The diagnostic performance of our approach, with a sensitivity of 88.6 % and NPV of 91.3 %, was compared decently with that of ResNet-50.
Background/purpose The purpose of this study was to assess the diagnostic performance of artificial neural networks (ANNs) to detect pneumoperitoneum in abdominal radiographs for the first time. Materials and methods This approach applied a novel deep-learning algorithm, a simple ANN training process without employing a convolution neural network (CNN), and also used a widely utilized deep-learning method, ResNet-50, for comparison. Results By applying ResNet-50 to abdominal radiographs, we obtained an area under the ROC curve (AUC) of 0.916 and an accuracy of 85.0 % with a sensitivity of 85.7 % and a predictive value of the negative tests (NPV) of 91.7 %. Compared with the most commonly applied deep-learning methods such as a CNN, our novel approach used extremely small ANN structures and a simple ANN training process. The diagnostic performance of our approach, with a sensitivity of 88.6 % and NPV of 91.3 %, was compared decently with that of ResNet-50. Conclusions The results of this study showed that ANN-based computer-assisted diagnostics can be used to accurately detect pneumoperitoneum in abdominal radiographs, reduce the time delay in diagnosing urgent diseases such as pneumoperitoneum, and increase the effectiveness of clinical practice and patient care.
Collapse
Affiliation(s)
- Mimi Kim
- Department of Radiology, Hanyang University Seoul Hospital, Seoul, Republic of Korea
| | - Jong Soo Kim
- Institute for Software Convergence, Hanyang University, Seoul, Republic of Korea
| | - Changhwan Lee
- Department of Biomedical Engineering, Hanyang University, Seoul, Republic of Korea
| | - Bo-Kyeong Kang
- Department of Radiology, Hanyang University Seoul Hospital, Seoul, Republic of Korea
| |
Collapse
|
265
|
Ye K, Chen M, Li J, Zhu Q, Lu Y, Yuan H. Ultra-low-dose CT reconstructed with ASiR-V using SmartmA for pulmonary nodule detection and Lung-RADS classifications compared with low-dose CT. Clin Radiol 2020; 76:156.e1-156.e8. [PMID: 33293025 DOI: 10.1016/j.crad.2020.10.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Accepted: 10/30/2020] [Indexed: 11/28/2022]
Abstract
AIM To evaluate the accuracy of ultra-low-dose computed tomography (ULDCT) with ASiR-V using a noise index (SmartmA) for pulmonary nodule detection and Lung CT Screening Reporting And Data System (Lung-RADS) classifications compared with low-dose CT (LDCT). MATERIALS AND METHODS Two-hundred and ten patients referred for lung cancer screening underwent conventional chest LDCT (0.80 ± 0.28 mSv) followed immediately by ULDCT (0.16 ± 0.03 mSv). ULDCT was scanned using 120 kV/SmartmA with a noise index of 28 HU and reconstructed with ASiR-V70%. The types and diameters of all nodules were recorded. The attenuation of pure ground-glass nodules (pGGNs) was measured on LDCT. All nodules were further classified using Lung-RADS. Sensitivities of nodule detection on ULDCT were analysed using LDCT as the reference standard. Logistic regression was used to establish a prediction model for the sensitivity of nodules. RESULTS LDCT revealed 362 nodules and the overall sensitivity on ULDCT was 90.1%. The sensitivity for solid nodules (SNs) of ≥1 mm diameter was 96.6% (228/236) and 100% (26/26) for SNs of ≥6 mm diameter. For pGGNs of ≥6 mm, the overall sensitivity was 93% (40/43) and 100% (29/29) for nodules with a attenuation value -700 HU or more. The agreement of Lung-RADS classification between two scans was good. On logistic regression, diameter was the only independent predictor for sensitivity of SNs (p<0.05). Diameter and attenuation value were predictors for pGGNs (p<0.05). CONCLUSION ULDCT with ASiR-V using SmartmA is suitable for lung-cancer screening in people with a BMI ≤35 kg/m2 as it has a low radiation dose of 0.16 mSv, high sensitivity for nodule detection and good performance of Lung-RADS classifications.
Collapse
Affiliation(s)
- K Ye
- Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China
| | - M Chen
- Department of Radiology, Ghent University Hospital, Corneel Heymanslaan 10, 9000, Ghent, Belgium
| | - J Li
- Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China
| | - Q Zhu
- Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China
| | - Y Lu
- Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China
| | - H Yuan
- Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, People's Republic of China.
| |
Collapse
|
266
|
Akyea-Larbi KO, Tetteh MA, Martinsen ACT, Hasford F, Inkoom S, Jensen K. BENCHMARKING OF A NEW AUTOMATIC CT RADIATION DOSE CALCULATOR. RADIATION PROTECTION DOSIMETRY 2020; 191:361-368. [PMID: 33151301 DOI: 10.1093/rpd/ncaa167] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 09/03/2020] [Accepted: 09/23/2020] [Indexed: 06/11/2023]
Abstract
Information on patient radiation dose is essential to meet the radiation protection regulations and the demands of dose optimization. Vendors have developed different tools for patient dose assessment for radiological purposes. In this study, estimated effective doses derived from a new image-based software tool (DoseWatch, GE Healthcare) was benchmarked against the corresponding doses from a dose calculator (CT-Expo, SASCRAD) and a conversion coefficient method. Dose data from 150 adult patients (66 male and 84 female), who underwent CT head, abdominopelvic or chest examinations, were retrospectively collected using DoseWatch. Effective dose estimated by DoseWatch was significantly lower than that of CT-Expo and DLP-E (k) (p ≤ 0.001). For the organ doses, DoseWatch resulted in lower dose than CT-Expo for all the organs with the exception of testis (p ≤ 001) and eye lenses (p ≤ 0.026).
Collapse
Affiliation(s)
- Kofi Okyere Akyea-Larbi
- Department of Medical Physics, School of Nuclear and Allied Sciences, University of Ghana, LG 25 Legon, Accra, Ghana
- Department of Physics, Norwegian University of Science and Technology (NTNU), NO-7491 Trondheim, Norway
| | - Mercy Afadzi Tetteh
- Department of Physics, Norwegian University of Science and Technology (NTNU), NO-7491 Trondheim, Norway
- Department of Diagnostic Physics, Oslo University Hospital, 0424 Oslo, Norway
| | - Anne Catrine T Martinsen
- Department of Diagnostic Physics, Oslo University Hospital, 0424 Oslo, Norway
- Faculty of Health sciences, Oslo Metropolitan University, N-0130 Oslo, Norway
| | - Francis Hasford
- Department of Medical Physics, School of Nuclear and Allied Sciences, University of Ghana, LG 25 Legon, Accra, Ghana
- Radiological and Medical Sciences Research Institute, Ghana Atomic Energy Commission, LG 80 Legon, Accra, Ghana
| | - Stephen Inkoom
- Department of Medical Physics, School of Nuclear and Allied Sciences, University of Ghana, LG 25 Legon, Accra, Ghana
- Radiation Protection Institute, Ghana Atomic Energy Commission, LG 80 Legon, Accra, Ghana
| | - Kristin Jensen
- Department of Diagnostic Physics, Oslo University Hospital, 0424 Oslo, Norway
| |
Collapse
|
267
|
Abeles M, Akerman M, Halaby C, Pirzada M. Do subtle findings on chest X-ray predict worse outcomes for paediatric asthma? Postgrad Med J 2020; 98:183-186. [PMID: 33273110 DOI: 10.1136/postgradmedj-2020-139165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 11/09/2020] [Accepted: 11/14/2020] [Indexed: 11/03/2022]
Abstract
BACKGROUND Asthma, a common childhood condition, often presents with chronic cough. While evaluating for chronic cough, many specialists obtain a baseline chest radiograph (CR) to assess for other causes. Usually read as 'normal', sometimes CRs will reveal evidence of airway inflammation in the form of subtle findings, such as 'increased interstitial markings' or 'peribronchial thickening'. There is sparse literature in the outpatient setting correlating findings on baseline CRs with adverse outcomes such as systemic steroid use, emergency department (ED) visit or hospitalisation. METHODS This was a retrospective study of patients seen at our institution's Pediatric Pulmonology outpatient clinic. We reviewed the charts of all new patients aged 0-18 years who presented between January 2015 and December 2017. Patients were included if they were diagnosed with asthma, had a CR after the initial visit and were followed up at least twice. Adverse outcomes include systemic steroid use, ED visit or hospitalisation. RESULTS 130 subjects were included. 89 subjects had clear CRs and 41 subjects had CRs with airway inflammation. Overall events were higher in the airway inflammation group (22.5% vs 46.3%, respectively, p<0.0058). There were no significant differences between in terms of oral corticosteroid use or hospitalisations. There was a significant difference between the two groups in terms of ED visits (2.2% vs 14.6%, respectively, p=0.0121). CONCLUSION This study shows a positive correlation between airway inflammation findings on baseline CR and subsequent ED visits in patients with asthma.
Collapse
Affiliation(s)
- Michael Abeles
- Pediatric Pulmonology, NYU Winthrop Hospital, Mineola, New York, USA
| | | | - Claudia Halaby
- Pediatric Pulmonology, NYU Winthrop Hospital, Mineola, New York, USA
| | - Melodi Pirzada
- Pediatric Pulmonology, NYU Winthrop Hospital, Mineola, New York, USA
| |
Collapse
|
268
|
Prasetyo M, Nindita N, Murdana IN, Prihartono J, Setiawan SI. Computed tomography evaluation of fat infiltration ratio of the multifidus muscle in chronic low back pain patients. Eur J Radiol Open 2020; 7:100293. [PMID: 33304941 PMCID: PMC7718153 DOI: 10.1016/j.ejro.2020.100293] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 11/24/2020] [Accepted: 11/24/2020] [Indexed: 12/11/2022] Open
Abstract
Background and objectives Fat infiltration of multifidus muscle is an important parameter to assess the efficacy of spinal stabilization training in chronic low back pain (LBP) patients. As a CT scan shows a specific attenuation value for fat, it can be used as a ratio to evaluate fat infiltration of the muscle relative to its cross-sectional area. This study aims to compare the fat infiltration ratio of multifidus muscle between subjects with and without chronic LBP in Indonesia. Methods Comparative cross-sectional study of 20 subjects with chronic LBP and 20 subjects without LBP. Fat infiltration ratio calculation of the multifidus muscle was obtained from the database of abdominal CT at the level of the superior and inferior endplate of L4 and L5 vertebral body. Results The fat infiltration ratio of multifidus muscle in the chronic LBP subjects group was significantly higher than the subjects group without NPB (p < 0.05). The cut-off value of the fat infiltration ratio at the level of the inferior endplate of L4 was 0.125 (75 % sensitivity and 80 % specificity). Conclusion The calculation of the multifidus muscle fat infiltration ratio at the inferior endplate L4 using CT is a potential method to evaluate multifidus muscle quality in chronic LBP patients.
Collapse
Affiliation(s)
- Marcel Prasetyo
- Department of Radiology, Faculty of Medicine Universitas Indonesia - Dr. Cipto Mangunkusumo National Central General Hospital, Jakarta, Indonesia
| | - Nadia Nindita
- Department of Radiology, Faculty of Medicine Universitas Indonesia - Dr. Cipto Mangunkusumo National Central General Hospital, Jakarta, Indonesia
| | - I Nyoman Murdana
- Department of Physical Medicine and Rehabilitation, Faculty of Medicine Universitas Indonesia - Dr. Cipto Mangunkusumo National Central General Hospital, Jakarta, Indonesia
| | - Joedo Prihartono
- Departement of Community Medicine, Faculty of Medicine Universitas Indonesia, Jakarta, Indonesia
| | - Stefanus Imanuel Setiawan
- Department of Radiology, Faculty of Medicine Universitas Indonesia - Dr. Cipto Mangunkusumo National Central General Hospital, Jakarta, Indonesia
| |
Collapse
|
269
|
García-Hernández T, Romero-Expósito M, Sánchez-Nieto B. Low dose radiation therapy for COVID-19: Effective dose and estimation of cancer risk. Radiother Oncol 2020; 153:289-295. [PMID: 33065184 PMCID: PMC7553901 DOI: 10.1016/j.radonc.2020.09.051] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2020] [Revised: 09/16/2020] [Accepted: 09/27/2020] [Indexed: 01/11/2023]
Abstract
BACKGROUND AND PURPOSE The objective of this work is to evaluate the risk of carcinogenesis of low dose ionizing radiation therapy (LDRT), for treatment of immune-related pneumonia following COVID-19 infection, through the estimation of effective dose and the lifetime attributable risk of cancer (LAR). MATERIAL AND METHODS LDRT treatment was planned in male and female computational phantoms. Equivalent doses in organs were estimated using both treatment planning system calculations and a peripheral dose model (based on ionization chamber measurements). Skin dose was estimated using radiochromic films. Later, effective dose and LAR were calculated following radiation protection procedures. RESULTS Equivalent doses to organs per unit of prescription dose range from 10 mSv/cGy to 0.0051 mSv/cGy. Effective doses range from 204 mSv to 426 mSv, for prescription doses ranging from 50 cGy to 100 cGy. Total LAR for a prescription dose of 50 cGy ranges from 1.7 to 0.29% for male and from 4.9 to 0.54% for female, for ages ranging from 20 to 80 years old. CONCLUSIONS The organs that mainly contribute to risk are lung and breast. Risk for out-of-field organs is low, less than 0.06 cases per 10000. Female LAR is on average 2.2 times that of a male of the same age. Effective doses are of the same order of magnitude as the higher-dose interventional radiology techniques. For a 60 year-old male, LAR is 8 times that from a cardiac CT, when prescription dose is 50 cGy.
Collapse
Affiliation(s)
| | - Maite Romero-Expósito
- Área de Ciencias Básicas y Ambientales, Instituto Tecnológico de Santo Domingo (INTEC), P.O. Box 342-9/249-2, Santo Domingo, Dominican Republic
| | | |
Collapse
|
270
|
Are Routine Follow-up Radiographs Necessary for Extra-articular Scapula Body Fractures Managed Conservatively? J Am Acad Orthop Surg 2020; 28:990-995. [PMID: 32235240 DOI: 10.5435/jaaos-d-19-00553] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Accepted: 02/22/2020] [Indexed: 02/01/2023] Open
Abstract
INTRODUCTION Extra-articular scapula body fractures have been shown to have good outcomes with nonsurgical management. What is not known is whether routine postinjury imaging of these fractures is necessary for monitoring healing and alignment. As the shift toward providing cost-effective healthcare continues, we sought to evaluate if routine postinjury imaging of these fractures resulted in any change in management while secondarily evaluating the imaging for fracture patterns at risk of displacement. METHODS A retrospective review of all extra-articular scapula body fractures managed nonsurgically at our institution was performed from January 2013 to December 2017. We measured the glenopolar angle, lateral border offset, sagittal angulation, and translation on both injury CT scans and follow-up radiographs to evaluate if any displacement occurred. In fractures that displaced more than 10 mm or 10° in any measurement, we evaluated the fracture pattern to see if any particular pattern posed a risk for displacement. In addition, we evaluated the cost of imaging for all radiographs obtained in the follow-up period. RESULTS A total of 139 patients with 147 extra-articular scapula body fractures were included in our analysis. No patient experienced a change in management based on postinjury radiographs. A total of 120 patients underwent postinjury imaging with a total of 204 radiographic series ordered, equating to $172,769.50 in radiograph expenses. Final radiographs were obtained at an average of 48.4 days postinjury, and overall, no significant difference was observed (P < 0.05) in any radiographic measurement when compared with the initial injury imaging; however, when looking at fractures that displaced, transverse fracture patterns of the scapula body represented a risk factor for displacement (relative risk = 6.5). DISCUSSION Satisfactory outcomes have previously been demonstrated with nonsurgical management of scapula body fractures and for most of these injuries postinjury imaging may not be necessary or cost effective. LEVEL OF EVIDENCE Level IV.
Collapse
|
271
|
Steadman J, Sripanich Y, Rungprai C, Mills MK, Saltzman CL, Barg A. Comparative assessment of midfoot osteoarthritis diagnostic sensitivity using weightbearing computed tomography vs weightbearing plain radiography. Eur J Radiol 2020; 134:109419. [PMID: 33259992 DOI: 10.1016/j.ejrad.2020.109419] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 11/02/2020] [Accepted: 11/16/2020] [Indexed: 12/31/2022]
Abstract
PURPOSE Accuracy in diagnosing osteoarthritis in the midfoot using weightbearing plain radiography (WBPR) remains questionable due to the overlapping osseous architecture present, occluding visualization. Weightbearing computed tomography (WBCT), providing clearer bony landmark identification and joint space visualization, can also be used for evaluation. The aim of this project is to perform a standardized retrospective intra-patient analysis identifying the discrepancy of midfoot osteoarthritis diagnosis and osteoarthritis severity grading between WBPR and WBCT. METHODS AND MATERIALS A cohort of 302 patient feet was acquired from an internal, consecutive patient database using detailed inclusion criteria. The musculoskeletal radiologist interpretation of the WBCT and WBPR of each specimen was then assessed for any direct diagnosis or mention of osteoarthritic signs in specific articulations of 3 midfoot joint groups (Chopart, "central", and tarsometatarsal). WBPR sensitivity and specificity metrics were calculated with WBCT considered the gold standard for comparison. RESULTS From the WBPR radiologist interpretation, we found diagnostic sensitivity of 72.5 % and specificity of 87.9 % for Chopart joints; 61.5 % sensitivity, and 96.1 % specificity for central joints; and 68.4 % sensitivity, and 92.9 % specificity for tarsometatarsal joints. The severity of degenerative changes was also consistently underestimated when interpreted from WBPR relative to WBCT. CONCLUSIONS In this series, midfoot osteoarthritis was often undetected on WBPR. WBCT imaging facilitates an earlier, more reliable diagnosis and grading of midfoot osteoarthritis relative to WBPR.
Collapse
Affiliation(s)
- Jesse Steadman
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108, USA.
| | - Yantarat Sripanich
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108, USA; Department of Orthopaedics, Phramongkutklao Hospital and College of Medicine, 315 Rajavithi Road, Tung Phayathai, Ratchathewi, Bangkok 10400, Thailand.
| | - Chamnanni Rungprai
- Department of Orthopaedics, Phramongkutklao Hospital and College of Medicine, 315 Rajavithi Road, Tung Phayathai, Ratchathewi, Bangkok 10400, Thailand.
| | - Megan K Mills
- Department of Radiology and Imaging Sciences, University of Utah, 30 N. 1900 E. #1A071, Salt Lake City, UT 84132, USA.
| | - Charles L Saltzman
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108, USA.
| | - Alexej Barg
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT 84108, USA; Department of Orthopaedics, Trauma and Reconstructive Surgery, University of Hamburg, Martinistrasse 52, 20246 Hamburg, Germany.
| |
Collapse
|
272
|
Murata K, Endo K, Aihara T, Suzuki H, Sawaji Y, Matsuoka Y, Nishimura H, Takamatsu T, Konishi T, Maekawa A, Yamauchi H, Kanazawa K, Endo H, Tsuji H, Inoue S, Fukushima N, Kikuchi H, Sato H, Yamamoto K. Artificial intelligence for the detection of vertebral fractures on plain spinal radiography. Sci Rep 2020; 10:20031. [PMID: 33208824 PMCID: PMC7674499 DOI: 10.1038/s41598-020-76866-w] [Citation(s) in RCA: 57] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 10/29/2020] [Indexed: 12/26/2022] Open
Abstract
Vertebral fractures (VFs) cause serious problems, such as substantial functional loss and a high mortality rate, and a delayed diagnosis may further worsen the prognosis. Plain thoracolumbar radiography (PTLR) is an essential method for the evaluation of VFs. Therefore, minimizing the diagnostic errors of VFs on PTLR is crucial. Image identification based on a deep convolutional neural network (DCNN) has been recognized to be potentially effective as a diagnostic strategy; however, the accuracy for detecting VFs has not been fully investigated. A DCNN was trained with PTLR images of 300 patients (150 patients with and 150 without VFs). The accuracy, sensitivity, and specificity of diagnosis of the model were calculated and compared with those of orthopedic residents, orthopedic surgeons, and spine surgeons. The DCNN achieved accuracy, sensitivity, and specificity rates of 86.0% [95% confidence interval (CI) 82.0-90.0%], 84.7% (95% CI 78.8-90.5%), and 87.3% (95% CI 81.9-92.7%), respectively. Both the accuracy and sensitivity of the model were suggested to be noninferior to those of orthopedic surgeons. The DCNN can assist clinicians in the early identification of VFs and in managing patients, to prevent further invasive interventions and a decreased quality of life.
Collapse
Affiliation(s)
- Kazuma Murata
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
| | - Kenji Endo
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Takato Aihara
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Hidekazu Suzuki
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Yasunobu Sawaji
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Yuji Matsuoka
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Hirosuke Nishimura
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Taichiro Takamatsu
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Takamitsu Konishi
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Asato Maekawa
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Hideya Yamauchi
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Kei Kanazawa
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Hiroo Endo
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Hanako Tsuji
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Shigeru Inoue
- Department of Preventive Medicine and Public Health, Tokyo Medical University, Tokyo, Japan
| | - Noritoshi Fukushima
- Department of Preventive Medicine and Public Health, Tokyo Medical University, Tokyo, Japan
| | - Hiroyuki Kikuchi
- Department of Preventive Medicine and Public Health, Tokyo Medical University, Tokyo, Japan
| | - Hiroki Sato
- Department of Preventive Medicine and Public Health, Tokyo Medical University, Tokyo, Japan
| | - Kengo Yamamoto
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| |
Collapse
|
273
|
Sun R, Ammari S, Bockel S, Achkar S, Merad M, Dercle L, Rivera S, Chargari C, Deutsch E. Optimization of Patient Management During the COVID-19 Pandemic: Chest CT Scan and PCR as Gatekeepers of the Radiation Therapy Workflow. Front Oncol 2020; 10:556334. [PMID: 33312944 PMCID: PMC7708327 DOI: 10.3389/fonc.2020.556334] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Accepted: 10/23/2020] [Indexed: 12/12/2022] Open
Affiliation(s)
- Roger Sun
- Gustave Roussy, Département de Radiothérapie, INSERM 1030, Université Paris-Saclay, Villejuif, France
| | - Samy Ammari
- Gustave Roussy, Département d’Imagerie Médicale, Université Paris-Saclay, Villejuif, France
| | - Sophie Bockel
- Gustave Roussy, Département de Radiothérapie, INSERM 1030, Université Paris-Saclay, Villejuif, France
| | - Samir Achkar
- Gustave Roussy, Département de Radiothérapie, INSERM 1030, Université Paris-Saclay, Villejuif, France
| | - Mansouria Merad
- Gustave Roussy, Département d’Oncologie Médicale, Université Paris-Saclay, Villejuif, France
| | - Laurent Dercle
- Department of Radiology, Columbia University Irving Medical Center, New York, NY, United States
| | - Sofia Rivera
- Gustave Roussy, Département de Radiothérapie, INSERM 1030, Université Paris-Saclay, Villejuif, France
| | - Cyrus Chargari
- Gustave Roussy, Département de Radiothérapie, INSERM 1030, Université Paris-Saclay, Villejuif, France
| | - Eric Deutsch
- Gustave Roussy, Département de Radiothérapie, INSERM 1030, Université Paris-Saclay, Villejuif, France
| |
Collapse
|
274
|
Arellano RS, Yang K, Rehani MM. Analysis of patients receiving ≥ 100 mSv during a computed tomography intervention. Eur Radiol 2020; 31:3065-3070. [PMID: 33180164 DOI: 10.1007/s00330-020-07458-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 08/27/2020] [Accepted: 11/03/2020] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To identify a patient cohort who received ≥ 100 mSv during a single computed tomography (CT)-guided intervention and analyze clinical information. MATERIALS AND METHODS Using the dose-tracking platform Radimetrics that collects data from all CT scanners in a single hospital, a patient-level search was performed retrospectively by setting a threshold effective dose (E) of 100 mSv for the period from January 2013 to December 2017. Patients who received ≥ 100 mSv in a single day during a single CT-guided intervention were then identified. Procedure types were identified, and medical records were reviewed up to January 2020 to identify patients who developed short- and/or medium-term (up to 8 years) medical consequences. RESULTS Of 8952 patients with 100 mSv+, there were 33 patients who underwent 37 CT-guided interventions each resulting in ≥ 100 mSv. Procedures included ablations (15), myelograms (8), drainages (7), biopsies (6), and other (1). The dose for individual procedures was 100.2 to 235.5 mSv with mean and median of 125.7 mSv and 111.8 mSv, respectively. Six patients (18 %) were less than 50 years of age. During the study period of 0.2 to 7 years, there were no deterministic or stochastic consequences identified in this study cohort. CONCLUSIONS While infrequent, CT-guided interventions may result in a single procedure dose of ≥ 100 mSv. Awareness of the possibility of such high doses and potential for long-term deleterious effects, especially in younger patients, and consideration of alternative imaging guidance and/or further dose optimization should be strongly considered whenever feasible. KEY POINTS • Although not so frequent, CT-guided interventions may result in a single procedure dose of ≥ 100 mSv • Procedures with potential for high dose includes ablations, myelograms, drainages, and biopsies.
Collapse
Affiliation(s)
- Ronald S Arellano
- Radiology Department, Massachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA.
| | - Kai Yang
- Radiology Department, Massachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA
| | - Madan M Rehani
- Radiology Department, Massachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA
| |
Collapse
|
275
|
Nead KT, Mitra N, Weathers B, Pyle L, Emechebe N, Pucci DA, Jacobs LA, Vaughn DJ, Nathanson KL, Kanetsky PA. Lower abdominal and pelvic radiation and testicular germ cell tumor risk. PLoS One 2020; 15:e0239321. [PMID: 33175879 PMCID: PMC7657535 DOI: 10.1371/journal.pone.0239321] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 09/04/2020] [Indexed: 11/18/2022] Open
Abstract
Background Testicular germ cell tumor (TGCT) incidence has increased in recent decades along with the use and dose of diagnostic radiation. Here we examine the association between reported exposure to diagnostic radiation and TGCT risk. Methods We conducted a case-control study of men with and without TGCT recruited from hospital- and population-based settings. Participants reported on exposures to 1) x-ray or CT below the waist and 2) lower GI series or barium enema, which consists of a series of x-rays of the colon. We also derived a combined measure of exposure. We used logistic regression to determine the risk of developing TGCT according to categories of exposures (0, 1–2, or ≥3 exposures) and age at first exposure, adjusting for age, year of birth, race, county, body mass index at diagnosis, family history of TGCT, and personal history of cryptorchidism. Results There were 315 men with TGCT and 931 men without TGCT in our study. Compared to no exposures, risk of TGCT was significantly elevated among those reporting at least three exposures to x-ray or CT (OR≥3 exposures, 1.78; 95% CI, 1.15–2.76; p = 0.010), lower GI series or barium enema (OR≥3 exposures, 4.58; 95% CI, 2.39–8.76; p<0.001), and the combined exposure variable (OR≥3 exposures, 1.59; 95% CI, 1.05–2.42; p = 0.029). The risk of TGCT was elevated for those exposed to diagnostic radiation at age 0–10 years, compared to those first exposed at age 18 years or later, although this association did not reach statistical significance (OR, 2.00; 95% CI, 0.91–4.42; p = 0.086). Conclusions Exposure to diagnostic radiation below the waist may increase TGCT risk. If these results are validated, efforts to reduce diagnostic radiation doses to the testes should be prioritized.
Collapse
Affiliation(s)
- Kevin T. Nead
- Department of Radiation Oncology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
- Department of Epidemiology, Department of Radiation Oncology, MD Anderson Cancer Center, Houston, Texas, United States of America
| | - Nandita Mitra
- Department of Biostatistics, Epidemiology and Informatics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Benita Weathers
- Division of Translational Medicine and Human Genetics, Department of Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Louisa Pyle
- Division of Translational Medicine and Human Genetics, Department of Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
- Division of Human Genetics and Metabolism, Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania, United States of America
| | - Nnadozie Emechebe
- Department of Cancer Epidemiology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, United States of America
- Department of Epidemiology and Biostatistics, College of Public Health, University of South Florida, Tampa, Florida, United States of America
| | - Donna A. Pucci
- Division of Hematology-Oncology, Department of Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Linda A. Jacobs
- Division of Hematology-Oncology, Department of Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
- Abramson Cancer Center, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - David J. Vaughn
- Division of Hematology-Oncology, Department of Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
- Abramson Cancer Center, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Katherine L. Nathanson
- Division of Translational Medicine and Human Genetics, Department of Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
- Abramson Cancer Center, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
- * E-mail:
| | - Peter A. Kanetsky
- Department of Cancer Epidemiology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, United States of America
| |
Collapse
|
276
|
Barba D, León-Sosa A, Lugo P, Suquillo D, Torres F, Surre F, Trojman L, Caicedo A. Breast cancer, screening and diagnostic tools: All you need to know. Crit Rev Oncol Hematol 2020; 157:103174. [PMID: 33249359 DOI: 10.1016/j.critrevonc.2020.103174] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 09/18/2020] [Accepted: 11/05/2020] [Indexed: 02/06/2023] Open
Abstract
Breast cancer is one of the most frequent malignancies among women worldwide. Methods for screening and diagnosis allow health care professionals to provide personalized treatments that improve the outcome and survival. Scientists and physicians are working side-by-side to develop evidence-based guidelines and equipment to detect cancer earlier. However, the lack of comprehensive interdisciplinary information and understanding between biomedical, medical, and technology professionals makes innovation of new screening and diagnosis tools difficult. This critical review gathers, for the first time, information concerning normal breast and cancer biology, established and emerging methods for screening and diagnosis, staging and grading, molecular and genetic biomarkers. Our purpose is to address key interdisciplinary information about these methods for physicians and scientists. Only the multidisciplinary interaction and communication between scientists, health care professionals, technical experts and patients will lead to the development of better detection tools and methods for an improved screening and early diagnosis.
Collapse
Affiliation(s)
- Diego Barba
- Escuela de Medicina, Universidad San Francisco de Quito USFQ, Quito, Ecuador; Instituto de Investigaciones en Biomedicina, Universidad San Francisco de Quito USFQ, Quito, Ecuador; Mito-Act Research Consortium, Quito, Ecuador
| | - Ariana León-Sosa
- Escuela de Medicina, Universidad San Francisco de Quito USFQ, Quito, Ecuador; Instituto de Investigaciones en Biomedicina, Universidad San Francisco de Quito USFQ, Quito, Ecuador; Mito-Act Research Consortium, Quito, Ecuador
| | - Paulina Lugo
- Hospital de los Valles HDLV, Quito, Ecuador; Fundación Ayuda Familiar y Comunitaria AFAC, Quito, Ecuador
| | - Daniela Suquillo
- Instituto de Investigaciones en Biomedicina, Universidad San Francisco de Quito USFQ, Quito, Ecuador; Mito-Act Research Consortium, Quito, Ecuador; Ingeniería en Procesos Biotecnológicos, Colegio de Ciencias Biológicas y Ambientales COCIBA, Universidad San Francisco de Quito USFQ, Quito, Ecuador
| | - Fernando Torres
- Escuela de Medicina, Universidad San Francisco de Quito USFQ, Quito, Ecuador; Hospital de los Valles HDLV, Quito, Ecuador
| | - Frederic Surre
- University of Glasgow, James Watt School of Engineering, Glasgow, G12 8QQ, United Kingdom
| | - Lionel Trojman
- LISITE, Isep, 75006, Paris, France; Universidad San Francisco de Quito USFQ, Colegio de Ciencias e Ingenierías Politécnico - USFQ, Instituto de Micro y Nanoelectrónica, IMNE, USFQ, Quito, Ecuador
| | - Andrés Caicedo
- Escuela de Medicina, Universidad San Francisco de Quito USFQ, Quito, Ecuador; Instituto de Investigaciones en Biomedicina, Universidad San Francisco de Quito USFQ, Quito, Ecuador; Mito-Act Research Consortium, Quito, Ecuador; Sistemas Médicos SIME, Universidad San Francisco de Quito USFQ, Quito, Ecuador.
| |
Collapse
|
277
|
Perret JL, Miles S, Brims F, Newbigin K, Davidson M, Jersmann H, Edwards A, Zosky G, Frankel A, Johnson AR, Hoy R, Reid DW, Musk AW, Abramson MJ, Edwards B, Cohen R, Yates DH. Respiratory surveillance for coal mine dust and artificial stone exposed workers in Australia and New Zealand: A position statement from the Thoracic Society of Australia and New Zealand. Respirology 2020; 25:1193-1202. [PMID: 33051927 PMCID: PMC7702073 DOI: 10.1111/resp.13952] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 07/19/2020] [Accepted: 08/11/2020] [Indexed: 12/17/2022]
Abstract
Coal mine lung dust disease (CMDLD) and artificial stone (AS) silicosis are preventable diseases which have occurred in serious outbreaks in Australia recently. This has prompted a TSANZ review of Australia's approach to respiratory periodic health surveillance. While regulating respirable dust exposure remains the foundation of primary and secondary prevention, identification of workers with early disease assists with control of further exposure, and with the aims of preserving lung function and decreasing respiratory morbidity in those affected. Prompt detection of an abnormality also allows for ongoing respiratory specialist clinical management. This review outlines a medical framework for improvements in respiratory surveillance to detect CMDLD and AS silicosis in Australia. This includes appropriate referral, improved data collection and interpretation, enhanced surveillance, the establishment of a nationwide Occupational Lung Disease Registry and an independent advisory group. These measures are designed to improve health outcomes for workers in the coal mining, AS and other dust-exposed and mining industries.
Collapse
Affiliation(s)
- Jennifer L. Perret
- Allergy and Lung Health Unit, Centre for Epidemiology and BiostatisticsThe University of MelbourneMelbourneVICAustralia
| | - Susan Miles
- Department of MedicineCalvary Mater NewcastleNewcastleNSWAustralia
- School of Medicine and Public HealthUniversity of NewcastleNewcastleNSWAustralia
| | - Fraser Brims
- Curtin Medical SchoolCurtin UniversityPerthWAAustralia
- Department of Respiratory MedicineSir Charles Gairdner HospitalPerthWAAustralia
| | | | - Maggie Davidson
- Health and Management School of ScienceWestern Sydney UniversitySydneyNSWAustralia
| | - Hubertus Jersmann
- Department of Thoracic MedicineRoyal Adelaide HospitalAdelaideSAAustralia
| | - Adrienne Edwards
- Christchurch Public HospitalCanterbury District Health BoardChristchurchNew Zealand
| | - Graeme Zosky
- Menzies Institute for Medical Research, College of Health and MedicineUniversity of TasmaniaHobartTASAustralia
- School of Medicine, College of Health and MedicineUniversity of TasmaniaHobartTASAustralia
| | - Anthony Frankel
- Bankstown HospitalSouth Western Sydney Local Heath DistrictSydneyNSWAustralia
- Department of MedicineUniversity of New South WalesSydneyNSWAustralia
| | | | - Ryan Hoy
- School of Public Health and Preventive MedicineMonash UniversityMelbourneVICAustralia
| | - David W. Reid
- QIMR‐Berghofer Institute of Medical ResearchBrisbaneQLDAustralia
| | - A. William Musk
- Department of Respiratory MedicineSir Charles Gairdner HospitalPerthWAAustralia
- School of Population HealthUniversity of Western AustraliaPerthWAAustralia
| | - Michael J. Abramson
- School of Public Health and Preventive MedicineMonash UniversityMelbourneVICAustralia
| | - Bob Edwards
- Wesley Dust Disease Research CentreBrisbaneQLDAustralia
| | - Robert Cohen
- School of Public Health, University of IllinoisChicagoILUSA
| | - Deborah H. Yates
- Department of Thoracic MedicineSt Vincent's HospitalSydneyNSWAustralia
- University of NSWSydneyNSWAustralia
| |
Collapse
|
278
|
Zangeneh M, Deevband MR, Mohsenzadeh B. Lifetime attributable risk of cancer incidence and mortality in routine digital radiology procedures. Clin Imaging 2020; 67:226-236. [DOI: 10.1016/j.clinimag.2020.08.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 07/14/2020] [Accepted: 08/10/2020] [Indexed: 11/26/2022]
|
279
|
Tulik M, Tulik P, Kowalska T. On the optimization of bone SPECT/CT in terms of image quality and radiation dose. J Appl Clin Med Phys 2020; 21:237-246. [PMID: 33111500 PMCID: PMC7700938 DOI: 10.1002/acm2.13069] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 10/03/2020] [Accepted: 10/05/2020] [Indexed: 12/24/2022] Open
Abstract
INTRODUCTION The purpose of this study was to present the optimization process of CT parameters to reduce patient exposure during bone SPECT/CT without affecting the quality of SPECT images with attenuation correction (AC). MATERIAL AND METHODS A fillable phantom reflecting realistic bone scintigraphy conditions was developed and acquired on an AnyScan SC. SPECT/CT scans were carried out with different x-ray tube current values (10, 20, 30, 40, 50, 60, 70, 90, 110, 130, 150, and 200 mA) at three different high-voltage values (80, 100, and 120 kV). The contrast (C) and coefficients of variation (CV) in the SPECT images as well as the signal-to-noise ratio (SNR) and noise (SDCT ) in the CT images with CTDIvol were measured. An optimal acquisition protocol that obtained SPECT/CT images with no artifacts on both CT and SPECT images, acceptable C, SNR, CV, and SDCT values, and the largest reduction in patient exposure compared to the reference acquisition procedure was sought. RESULTS The optimal set of parameters for bone SPECT/CT was determined based on a phantom study. It has been implemented in clinical practice. Two groups of patients were examined according to the baseline and optimized protocols, respectively. The new SPECT/CT protocol substantially reduced patients' radiation exposure compared to the old protocol while maintaining the required diagnostic quality of SPECT and CT images. CONCLUSIONS In the study, we present a methodology that finds a compromise between diagnostic information and patient exposure during bone SPECT/CT procedures.
Collapse
Affiliation(s)
- Monika Tulik
- Maria Sklodowska-Curie National Research Institute of Oncology Krakow Branch, Krakow, Poland
| | - Piotr Tulik
- Warsaw University of Technology, Faculty of Mechatronics, Institute of Metrology and Biomedical Engineering, Warsaw, Poland
| | - Teresa Kowalska
- Maria Sklodowska-Curie National Research Institute of Oncology Krakow Branch, Krakow, Poland
| |
Collapse
|
280
|
A A, A N, S S, S S. Measurement of Entrance Skin Dose and the Dose Received by Different Organs in Panoramic Dental Imaging. J Biomed Phys Eng 2020; 10:569-574. [PMID: 33134215 PMCID: PMC7557459 DOI: 10.31661/jbpe.v0i0.878] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2018] [Accepted: 03/20/2018] [Indexed: 11/16/2022]
Abstract
Background: Thermoluminescence dosimetry(TLD) has been known as one of the most effective methods for dose estimation in diagnostic radiology. Orthopantomogram (OPG) imaging is used by many dentists, oral and maxillofacial surgeons as an effective tool for choosing an appropriate treatment plan. Objective: This study aims to measure the entrance skin dose and the dose values received by different head and neck organs in OPG imaging using TLD dosimeters (TLD-100). Material and Methods: In this experimental study, the entrance skin dose and doses of various organs during imaging were measured by TLD dosimeters inside and on the surface of the Rando-Phantom. Doses to various organs, including thyroid, eye, esophagus, parotid and sublingual and submandibular salivary glands were measured. The measurements were repeated twice, and the dose values obtained in the two steps were compared. Results: Based on the results obtained in this study, the minimum dose values were found in Esophagus; 65.81, and 59.31 µGy, respectively. The maximum organ dose value was found for left parotid glands, 3842.42, and 3399.58 for the two measurements, respectively. Conclusion: The results show that the dose values can vary based on devices, exposure conditions, and TLD positioning.
Collapse
Affiliation(s)
- Ahmadi A
- MSc, Kerman Graduate University of Advanced Technology, Kerman, Iran
| | - Negarestani A
- PhD, Kerman Graduate University of Advanced Technology, Kerman, Iran
| | - Sina S
- PhD, Radiation Research Center, Shiraz University, Shiraz, Iran
| | - Sarshough S
- PhD, Department of Nuclear Engineering, Shiraz University, Shiraz, Iran
| |
Collapse
|
281
|
The Risk of Cancer from CT Scans and Other Sources of Low-Dose Radiation: A Critical Appraisal of Methodologic Quality. Prehosp Disaster Med 2020; 35:3-16. [PMID: 32009606 DOI: 10.1017/s1049023x1900520x] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
INTRODUCTION Concern exists that radiation exposure from computerized tomography (CT) will cause thousands of malignancies. Other experts share the same perspective regarding the risk from additional sources of low-dose ionizing radiation, such as the releases from Three Mile Island (1979; Pennsylvania USA) and Fukushima (2011; Okuma, Fukushima Prefecture, Japan) nuclear power plant disasters. If this premise is false, the fear of cancer leading patients and physicians to avoid CT scans and disaster responders to initiate forced evacuations is unfounded. STUDY OBJECTIVE This investigation provides a quantitative evaluation of the methodologic quality of studies to determine the evidentiary strength supporting or refuting a causal relationship between low-dose radiation and cancer. It will assess the number of higher quality studies that support or question the role of low-dose radiation in oncogenesis. METHODS This investigation is a systematic, methodologic review of articles published from 1975-2017 examining cancer risk from external low-dose x-ray and gamma radiation, defined as less than 200 millisievert (mSv). Following the PRISMA guidelines, the authors performed a search of the PubMed, Cochrane, Scopus, and Web of Science databases. Methodologies of selected articles were scored using the Newcastle Ottawa Scale (NOS) and a tool identifying 11 lower quality indicators. Manuscript methodologies were ranked as higher quality if they scored no lower than seven out of nine on the NOS and contained no more than two lower quality indicators. Investigators then characterized articles as supporting or not supporting a causal relationship between low-dose radiation and cancer. RESULTS Investigators identified 4,382 articles for initial review. A total of 62 articles met all inclusion/exclusion criteria and were evaluated in this study. Quantitative evaluation of the manuscripts' methodologic strengths found 25 studies met higher quality criteria while 37 studies met lower quality criteria. Of the 25 studies with higher quality methods, 21 out of 25 did not support cancer induction by low-dose radiation (P = .0003). CONCLUSIONS A clear preponderance of articles with higher quality methods found no increased risk of cancer from low-dose radiation. The evidence suggests that exposure to multiple CT scans and other sources of low-dose radiation with a cumulative dose up to 100 mSv (approximately 10 scans), and possibly as high as 200 mSv (approximately 20 scans), does not increase cancer risk.
Collapse
|
282
|
Hill KL, Gross ME, Sutton KM, Mulcahey MK. Evaluation and Resuscitation of the Pregnant Orthopaedic Trauma Patient: Considerations for Maternal and Fetal Outcomes. JBJS Rev 2020; 7:e3. [PMID: 31841448 DOI: 10.2106/jbjs.rvw.19.00013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Kelly L Hill
- Department of Orthopaedic Surgery (K.L.H. and M.K.M.), Tulane University School of Medicine (M.E.G.), New Orleans, Louisiana
| | - Maya E Gross
- Department of Orthopaedic Surgery (K.L.H. and M.K.M.), Tulane University School of Medicine (M.E.G.), New Orleans, Louisiana
| | | | - Mary K Mulcahey
- Department of Orthopaedic Surgery (K.L.H. and M.K.M.), Tulane University School of Medicine (M.E.G.), New Orleans, Louisiana
| |
Collapse
|
283
|
D'Alessio I, Domanin M, Bissacco D, Rimoldi P, Palmieri B, Piffaretti G, Trimarchi S. Thoracic endovascular aortic repair for traumatic aortic injuries: insight from literature and practical recommendations. THE JOURNAL OF CARDIOVASCULAR SURGERY 2020; 61:681-696. [PMID: 32964899 DOI: 10.23736/s0021-9509.20.11580-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
INTRODUCTION Thoracic endovascular aortic repair (TEVAR) for treatment of blunt traumatic aortic injuries (BTAIs) is nowadays the gold standard technique in adult patients, replacing gradually the use of open repair (OR). Although randomized controlled trials will never be performed comparing TEVAR to OR for BTAIs management, trauma and vascular societies guidelines today primarily recommend the former for BTAI patients with a suitable anatomy. The aim of this review was to describe past and recent data published in literature regarding pros and cons of TEVAR treatment in BTAI, and to analyze some debated issues and future perspectives. EVIDENCE ACQUISITION Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and Scale for the Assessment of Narrative Review Articles (SANRA) were used to obtain and describe selected articles on TEVAR in BTAI. EVIDENCE SYNTHESIS Young (<50 years) men were the most operated population. The use of TEVAR increased over the years, with a progressive reduction in mortality and overall postoperative complication rates when compared with OR. Lack of information remains about the percentage of urgent cases. CONCLUSIONS TEVAR is considered nowadays the treatment of choice in BTAI patients. In case of aortic rupture (grade IV) the treatment is mandatory, while intimal tear (grade I) and intramural hematoma (grade II) can be safely managed with no operative management (NOM). Debate is still ongoing on grade III (pseudoaneurysms). Unfortunately, several aspects remain not yet clarified, including disease classification, type and grade to treat, timing (urgent versus elective), priority of vascular injuries in polytrauma patients, and TEVAR use in pediatrics and young patients.
Collapse
Affiliation(s)
- Ilenia D'Alessio
- Unit of Vascular Surgery, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Maurizio Domanin
- Unit of Vascular Surgery, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy - .,Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy
| | - Daniele Bissacco
- Unit of Vascular Surgery, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Pierantonio Rimoldi
- Department of Cardio-Thoraco-Vascular Surgery, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Bruno Palmieri
- Department of Cardio-Thoraco-Vascular Surgery, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Gabriele Piffaretti
- Unit of Vascular Surgery, Department of Medicine and Surgery, University of Insubria School of Medicine, Varese, Italy
| | - Santi Trimarchi
- Unit of Vascular Surgery, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.,Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy
| |
Collapse
|
284
|
Dundara Debeljuh D, Jurković S, Pribanić I, Poljak F, Kralik I, Krstonošić B, Bralić A, Bajan T, Božac Jokić O, Vidošević L, Kumrić D, Zrilić I, Šegota D, Diklić A, Smilović Radojčić Đ, Vassileva J. National survey to set diagnostic reference levels in nuclear medicine single photon emission imaging in Croatia. Phys Med 2020; 78:109-116. [PMID: 32956917 DOI: 10.1016/j.ejmp.2020.09.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 08/10/2020] [Accepted: 09/01/2020] [Indexed: 12/25/2022] Open
Abstract
PURPOSE In order to introduce the concept of diagnostic reference levels (DRLs) in the national nuclear medicine practice a survey was proposed and completed through all nuclear medicine departments in Croatia. An additional aim was to increase the awareness of importance and full implementation of a comprehensive quality program that includes devices used in the nuclear medicine chain. METHODS Data were collected for more than 30 nuclear medicine single photon emission procedures. National DRLs (NDRLs) as administered activity and also as administered activity per unit mass were calculated in accordance to International Commission on Radiological Protection (ICRP) recommendations. Additionally, effective doses were estimated using conversion factors published by the ICRP. RESULTS NDRLs for nuclear medicine single photon emission procedures were proposed. For procedures performed in only one department typical values were presented as reference. Effective doses related to applied radiopharmaceuticals were calculated to estimate radiation risk related to respective nuclear medicine procedure in more detail. CONCLUSION This work presents results of the first national survey on DRLs of nuclear medicine single photon emission procedures and proposes reliable NDRLs that represent an actual status of nuclear medicine practice in Croatia. Results have motivated departments to introduce and set their own typical values to be used, as one of the tools, for further optimization process. One of the drawbacks of the DRL concept in nuclear medicine is the lack of the image quality parameters involved. For this reason, a quantity that considers both radiation protection and image quality should be introduced.
Collapse
Affiliation(s)
- Dea Dundara Debeljuh
- University Hospital Rijeka, Department for Medical Physics and Radiation Protection, Krešimirova 42, Rijeka, Croatia; General Hospital Pula, Department of Radiology, Santoriova 24a, Pula, Croatia; University of Rijeka, Faculty of Medicine, Nuclear Medicine Department, Braće Branchetta 20/1, Rijeka, Croatia.
| | - Slaven Jurković
- University Hospital Rijeka, Department for Medical Physics and Radiation Protection, Krešimirova 42, Rijeka, Croatia; University of Rijeka, Faculty of Medicine, Department of Medical Physics and Biophysics, Rijeka, Croatia
| | - Ivan Pribanić
- University Hospital Rijeka, Department for Medical Physics and Radiation Protection, Krešimirova 42, Rijeka, Croatia; University of Rijeka, Faculty of Medicine, Nuclear Medicine Department, Braće Branchetta 20/1, Rijeka, Croatia
| | - Frano Poljak
- University Hospital Center Zagreb, Division of Medical Physics, Department of Nuclear Medicine and Radiation Protection, Kišpatićeva ulica 12, Zagreb, Croatia
| | - Ivana Kralik
- University Hospital Dubrava, Department of Diagnostic and Interventional Radiology, Avenija Gojka Šuška 6, Zagreb, Croatia
| | - Branislav Krstonošić
- Osijek University Hospital, Department of Medical Physics, Osijek, Josipa Huttlera 4, Croatia
| | - Ante Bralić
- University Hospital Centre Split, Department of Medical Physics, Spinčićeva 1, Split, Croatia
| | - Tamara Bajan
- University Clinical Hospital Center Sestre Milosrdnice, Department of Medical Physics, Vinogradska 29, Zagreb, Croatia
| | - Ondina Božac Jokić
- General Hospital Pula, Department of Nuclear Medicine, Zagrebačka 34, Pula, Croatia
| | - Ljiljana Vidošević
- General Hospital Šibenik, Department of Endocrinology, Diabetology, Metabolic Diseases and Nuclear Medicine, Bože Peričića 16, 22000 Šibenik, Croatia
| | - Danijela Kumrić
- General Hospital Varaždin, Department of Nuclear Medicine, Ivana Meštrovića 1, 42000 Varaždin, Croatia
| | - Ivana Zrilić
- General Hospital Zadar, Department of Oncology and Nuclear Medicine, Bože Peričića 5, 23000 Zadar, Croatia
| | - Doris Šegota
- University Hospital Rijeka, Department for Medical Physics and Radiation Protection, Krešimirova 42, Rijeka, Croatia; University of Rijeka, Faculty of Medicine, Radiology Department, Rijeka, Croatia
| | - Ana Diklić
- University Hospital Rijeka, Department for Medical Physics and Radiation Protection, Krešimirova 42, Rijeka, Croatia; University of Rijeka, Faculty of Medicine, Department of Medical Physics and Biophysics, Rijeka, Croatia
| | - Đeni Smilović Radojčić
- University Hospital Rijeka, Department for Medical Physics and Radiation Protection, Krešimirova 42, Rijeka, Croatia; University of Rijeka, Faculty of Medicine, Department of Medical Physics and Biophysics, Rijeka, Croatia
| | - Jenia Vassileva
- International Atomic Energy Agency, Radiation Protection of Patients Unit, Vienna International Centre, PO Box 100, 1400 Vienna, Austria
| |
Collapse
|
285
|
Pyper M, Sidiqi A, Rogalla P, Sabbah S, Kielar A. CT Abdominal Tomography Indications: Are We All Sticking to the Plan? Can Assoc Radiol J 2020; 72:736-741. [PMID: 32903020 DOI: 10.1177/0846537120951078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
OBJECTIVE Ultra-low radiation dose computed tomography (CT) abdominal tomography was introduced in our institution in 2016 to replace standard abdominal radiography in the investigation of emergency department patients. This project aims to ascertain whether investigation of emergency department patients using ultra-low radiation dose CT abdominal tomography complies with original indication guidelines and/or if there has been any "indication creep" 3 years after inception. METHODS Retrospective, quality assurance project with research ethics waiver. A review of 200 consecutive patients investigated with CT abdominal tomography between February and May 2017 was performed. This was compared with 200 consecutive patients investigated between February and May 2019. Data analyzed included patient demographics, indication for scan, as well as scan and patient outcomes. RESULTS In the 2017 group, 29/200 scans were noncompliant with approved indication guidelines. In the 2019 group, 30/200 scans were also noncompliant. There was no statistically significant difference between groups (P < .05) regarding the use of approved indications. Forty of 200 scans performed in 2017 revealed additional findings which are not specifically addressed on the reporting template. Forty-one of 200 scans in 2019 revealed these findings. CONCLUSIONS There has been no "indication creep" for CT abdominal tomography over time.
Collapse
Affiliation(s)
- Michael Pyper
- Toronto General Hospital, Toronto, ON, Canada.,Royal Victoria Hospital, Belfast, Northern Ireland, UK
| | | | | | - Sam Sabbah
- Toronto General Hospital, Toronto, ON, Canada
| | - Ania Kielar
- Toronto General Hospital, Toronto, ON, Canada
| |
Collapse
|
286
|
Abstract
Lung cancer is the leading cause of US cancer-related deaths. Lung cancer screening with a low radiation dose chest computed tomography scan is now standard of care for a high-risk eligible population. It is imperative for clinicians and surgeons to evaluate the trade-offs of benefits and harms, including the identification of many benign lung nodules, overdiagnosis, and complications. Integration of smoking cessation interventions augments the clinical benefits of screening. Screening programs must develop strategies to manage screening-detected findings to minimize potential harms. Further research should focus on how to improve patient selection, minimize harms, and facilitate access to screening.
Collapse
Affiliation(s)
- Humberto K Choi
- Respiratory Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA.
| | - Peter J Mazzone
- Respiratory Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| |
Collapse
|
287
|
Neira S, Guiu‐Souto J, Díaz‐Botana P, Pais P, Fernández C, Pubul V, Ruibal Á, Candela‐Juan C, Gago‐Arias A, Pombar M, Pardo‐Montero J. Quantification of internal dosimetry in PET patients: individualized Monte Carlo vs generic phantom-based calculations. Med Phys 2020; 47:4574-4588. [PMID: 32569389 PMCID: PMC7586975 DOI: 10.1002/mp.14344] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Revised: 06/11/2020] [Accepted: 06/12/2020] [Indexed: 12/15/2022] Open
Abstract
PURPOSE The purpose of this work is to calculate individualized dose distributions in patients undergoing 18 F-FDG PET/CT studies through a methodology based on full Monte Carlo (MC) simulations and PET/CT patient images, and to compare such values with those obtained by employing nonindividualized phantom-based methods. METHODS We developed a MC-based methodology for individualized internal dose calculations, which relies on CT images (for organ segmentation and dose deposition), PET images (for organ segmentation and distributions of activities), and a biokinetic model (which works with information provided by PET and CT images) to obtain cumulated activities. The software vGATE version 8.1. was employed to carry out the Monte Carlo calculations. We also calculated deposited doses with nonindividualized phantom-based methods (Cristy-Eckerman, Stabin, and ICRP-133). RESULTS Median MC-calculated dose/activity values are within 0.01-0.03 mGy/MBq for most organs, with higher doses delivered especially to the bladder wall, major vessels, and brain (medians of 0.058, 0.060, 0.066 mGy/MBq, respectively). Comparison with values obtained with nonindividualized phantom-based methods has shown important differences in many cases (ranging from -80% to + 260%). These differences are significant (p < 0.05) for several organs/tissues, namely, remaining tissues, adrenals, bladder wall, bones, upper large intestine, heart, pancreas, skin, and stomach wall. CONCLUSIONS The methodology presented in this work is a viable and useful method to calculate internal dose distributions in patients undergoing medical procedures involving radiopharmaceuticals, individually, with higher accuracy than phantom-based methods, fulfilling the guidelines provided by the European Council directive 2013/59/Euratom.
Collapse
Affiliation(s)
- Sara Neira
- Group of Medical Physics and BiomathematicsInstituto de Investigación Sanitaria de SantiagoTravesía Choupana s/nSantiago de Compostela15706Spain
| | - Jacobo Guiu‐Souto
- Department of Medical PhysicsCentro Oncolóxico de GaliciaC/ Doctor Camilo Beiras 1Coruña15009 ASpain
| | - Pablo Díaz‐Botana
- Group of Medical Physics and BiomathematicsInstituto de Investigación Sanitaria de SantiagoTravesía Choupana s/nSantiago de Compostela15706Spain
- Galician Supercomputation Center (CESGA)Avenida de Vigo s/nSantiago de Compostela15705Spain
| | - Paulino Pais
- Department of Nuclear MedicineCentro Oncolóxico de GaliciaC/ Doctor Camilo Beiras 1Coruña15009 ASpain
| | - Carlos Fernández
- Department of Medical PhysicsCentro Oncolóxico de GaliciaC/ Doctor Camilo Beiras 1Coruña15009 ASpain
| | - Virginia Pubul
- Department of Nuclear MedicineComplexo Hospitalario Universitario de Santiago de CompostelaTravesía Choupana s/nSantiago de Compostela15706Spain
| | - Álvaro Ruibal
- Department of Nuclear MedicineComplexo Hospitalario Universitario de Santiago de CompostelaTravesía Choupana s/nSantiago de Compostela15706Spain
- Group of Molecular Imaging and OncologyInstituto de Investigación Sanitaria de Santiago, Travesía Choupana s/nSantiago de Compostela15706Spain
- Molecular Imaging GroupDepartment of RadiologyFaculty of MedicineUniversidade de Santiago de CompostelaCampus VidaSantiago de Compostela15782Spain
- Fundación TejerinaC/ José Abascal 40Madrid28003Spain
| | - Cristian Candela‐Juan
- Centro Nacional de DosimetríaInstituto Nacional de Gestión SanitariaAv. Campanar 21Valencia46009Spain
| | - Araceli Gago‐Arias
- Group of Medical Physics and BiomathematicsInstituto de Investigación Sanitaria de SantiagoTravesía Choupana s/nSantiago de Compostela15706Spain
- Instituto de FísicaPontificia Universidad Católica de ChileSantiagoChile
| | - Miguel Pombar
- Group of Molecular Imaging and OncologyInstituto de Investigación Sanitaria de Santiago, Travesía Choupana s/nSantiago de Compostela15706Spain
- Department of Medical PhysicsComplexo Hospitalario Universitario de Santiago de CompostelaTravesía da Choupana s/nSantiago de Compostela15706Spain
| | - Juan Pardo‐Montero
- Group of Medical Physics and BiomathematicsInstituto de Investigación Sanitaria de SantiagoTravesía Choupana s/nSantiago de Compostela15706Spain
- Department of Medical PhysicsComplexo Hospitalario Universitario de Santiago de CompostelaTravesía da Choupana s/nSantiago de Compostela15706Spain
| |
Collapse
|
288
|
Establishment of Submillisievert Abdominal CT Protocols With an In Vivo Swine Model and an Anthropomorphic Phantom. AJR Am J Roentgenol 2020; 215:685-694. [DOI: 10.2214/ajr.19.22053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
289
|
Chest X-ray and Uveitis Evaluation in a Population with Low Incidence of Sarcoidosis. Ophthalmol Ther 2020; 9:577-584. [PMID: 32613593 PMCID: PMC7406623 DOI: 10.1007/s40123-020-00274-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Indexed: 11/01/2022] Open
Abstract
Introduction Methods Results Conclusions
Collapse
|
290
|
The Effect of Low Temperatures on Environmental Radiation Damage in Living Systems: Does Hypothermia Show Promise for Space Travel? Int J Mol Sci 2020; 21:ijms21176349. [PMID: 32882991 PMCID: PMC7504535 DOI: 10.3390/ijms21176349] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 08/31/2020] [Accepted: 08/31/2020] [Indexed: 12/23/2022] Open
Abstract
Low-temperature treatments (i.e., hypothermia) may be one way of regulating environmental radiation damage in living systems. With this in mind, hibernation under hypothermic conditions has been proposed as a useful approach for long-term human space flight. However, the underlying mechanisms of hypothermia-induced radioresistance are as yet undetermined, and the conventional risk assessment of radiation exposure during hibernation remains insufficient for estimating the effects of chronic exposure to galactic cosmic rays (GCRs). To promote scientific discussions on the application of hibernation in space travel, this literature review provides an overview of the progress to date in the interdisciplinary research field of radiation biology and hypothermia and addresses possible issues related to hypothermic treatments as countermeasures against GCRs. At present, there are concerns about the potential effects of chronic radiation exposure on neurological disorders, carcinogenesis, ischemia heat failures, and infertility in astronauts; these require further study. These concerns may be resolved by comparing and integrating data gleaned from experimental and epidemiological studies.
Collapse
|
291
|
Zander A, Paunesku T, Woloschak GE. Analyses of cancer incidence and other morbidities in gamma irradiated B6CF1 mice. PLoS One 2020; 15:e0231510. [PMID: 32818954 PMCID: PMC7440931 DOI: 10.1371/journal.pone.0231510] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Accepted: 07/21/2020] [Indexed: 12/12/2022] Open
Abstract
With increasing medical radiation exposures, it is important to understand how different modes of delivery of ionizing radiation as well as total doses of exposure impact health outcomes. Our lab studied the risks associated with ionizing radiation by analyzing the Northwestern University Radiation Archive for animals (NURA). NURA contains detailed data from a series of 10 individual neutron and gamma irradiation experiments conducted on over 50,000 mice. Rigorous statistical testing on control mice from all Janus experiments enabled us to select studies that could be compared to one another and uncover unexpected differences among the controls as well as experimental animals. For controls, mice sham irradiated with 300 fractions died significantly earlier than those with fewer sham fractions and were excluded from the pooled dataset. Using the integrated dataset of gamma irradiated and control mice, we found that fractionation significantly decreased the death hazard for animals dying of lymphomas, tumors, non-tumors, and unknown causes. Gender differences in frequencies of causes of death were identified irrespective of irradiation and dose fractionation, with female mice being at a greater risk for all causes of death, except for lung tumors. Irradiated and control male mice were at a significantly greater risk for lung tumors, the opposite from observations noted in humans. Additionally, we discovered that lymphoma deaths can occur quickly after exposures to high doses of gamma rays. This study systematically cross-compared outcomes of different modes of fractionation evaluated across different Janus experiments and across a wide span of total doses. It demonstrates that protraction modulated survival and disease status differently based on the total dose, cause of death, and sex of an animal. This novel method for analyzing the Janus datasets will lead to insightful new mechanistic hypotheses and research in the fields of radiation biology and protection.
Collapse
Affiliation(s)
- Alia Zander
- Feinberg School of Medicine, Radiation Oncology, Northwestern University, Chicago, IL, United States of America
| | - Tatjana Paunesku
- Feinberg School of Medicine, Radiation Oncology, Northwestern University, Chicago, IL, United States of America
| | - Gayle E. Woloschak
- Feinberg School of Medicine, Radiation Oncology, Northwestern University, Chicago, IL, United States of America
- * E-mail:
| |
Collapse
|
292
|
Baena-Navarro R, Torres-Hoyos F, Uc-Rios C, Colmenares-Quintero RF. Design and assembly of an IoT-based device to determine the absorbed dose of gamma and UV radiation. Appl Radiat Isot 2020; 166:109359. [PMID: 32739748 DOI: 10.1016/j.apradiso.2020.109359] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Revised: 07/12/2020] [Accepted: 07/22/2020] [Indexed: 11/17/2022]
Abstract
Ionizing and non-ionizing radiations are part of our daily life, and when organisms are exposed to them for a long time, they may experience their lethal or sublethal effects. For this reason, technologies have been created to quantify them. In this study, Internet of Things (IoT) was used through connecting gamma meters and a low-cost UV radiation device. The validation of this structure was performed with meters calibrated in certified laboratories. The validation results matched those obtained by the other devices, with an error of 2%.
Collapse
Affiliation(s)
- R Baena-Navarro
- Universidad Internacional Iberoamericana, 24560, Campeche, Mexico; Department of Systems Engineering, Universidad Cooperativa de Colombia 230002, Montería, Colombia.
| | - F Torres-Hoyos
- Department of Physics, Universidad de Córdoba 230002, Montería, Colombia; Department of Systems Engineering, Universidad Cooperativa de Colombia 230002, Montería, Colombia.
| | - C Uc-Rios
- Universidad Internacional Iberoamericana, 24560, Campeche, Mexico.
| | | |
Collapse
|
293
|
Bouwer NI, Jager A, Liesting C, Kofflard MJM, Brugts JJ, Kitzen JJEM, Boersma E, Levin MD. Cardiac monitoring in HER2-positive patients on trastuzumab treatment: A review and implications for clinical practice. Breast 2020; 52:33-44. [PMID: 32361151 PMCID: PMC7375662 DOI: 10.1016/j.breast.2020.04.005] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Revised: 03/17/2020] [Accepted: 04/13/2020] [Indexed: 12/12/2022] Open
Abstract
Trastuzumab prolongs progression-free and overall survival in patients with human epidermal growth factor receptor 2 (HER2) positive breast cancer. However, trastuzumab treatment is hampered by cardiotoxicity, defined as a left ventricular ejection fraction (LVEF) decline with a reported incidence ranging from 3 to 27% depending on variable factors. Early identification of patients at increased risk of trastuzumab-induced myocardial damage is of great importance to prevent deterioration to irreversible cardiotoxicity. Although current cardiac monitoring with multi gated acquisition (MUGA) scanning and/or conventional 2D-echocardiography (2DE) have a high availability, their reproducibility are modest, and more sensitive and reliable techniques are needed such as 3D-echocardiography (3DE) and speckle tracking echocardiography (STE). But which other diagnostic imaging modalities are available for patients before and during trastuzumab treatment? In addition, what is the optimal frequency and duration of cardiac monitoring? At last, which biomarker monitoring strategies are currently available for the identification of cardiotoxicity in patients treated with trastuzumab?
Collapse
Affiliation(s)
- Nathalie I Bouwer
- Department of Cardiology, Albert Schweitzer Hospital, Albert Schweitzerplaats 25, 3300 AK, Dordrecht, the Netherlands; Department of Internal Medicine, Albert Schweitzer Hospital, Albert Schweitzerplaats 25, 3300 AK, Dordrecht, the Netherlands
| | - Agnes Jager
- Department of Medical Oncology, Erasmus MC Cancer Institute, Dr. Molewaterplein 40, 3000 CA, Rotterdam, the Netherlands
| | - Crista Liesting
- Department of Cardiology, Albert Schweitzer Hospital, Albert Schweitzerplaats 25, 3300 AK, Dordrecht, the Netherlands
| | - Marcel J M Kofflard
- Department of Cardiology, Albert Schweitzer Hospital, Albert Schweitzerplaats 25, 3300 AK, Dordrecht, the Netherlands
| | - Jasper J Brugts
- Department of Cardiology, Erasmus MC Thoraxcenter, Dr. Molewaterplein 40, 3000 CA, Rotterdam, the Netherlands
| | - Jos J E M Kitzen
- Department of Internal Medicine, Albert Schweitzer Hospital, Albert Schweitzerplaats 25, 3300 AK, Dordrecht, the Netherlands
| | - Eric Boersma
- Department of Cardiology, Erasmus MC Thoraxcenter, Dr. Molewaterplein 40, 3000 CA, Rotterdam, the Netherlands
| | - Mark-David Levin
- Department of Internal Medicine, Albert Schweitzer Hospital, Albert Schweitzerplaats 25, 3300 AK, Dordrecht, the Netherlands.
| |
Collapse
|
294
|
Weinrich JM, Warncke M, Wiese N, Regier M, Tahir E, Heinemann A, Sehner S, Püschel K, Adam G, Laqmani A. Feasibility of extremely reduced-dose CT of the thoracic spine in human cadavers. Acta Radiol 2020; 61:1034-1041. [PMID: 31840526 DOI: 10.1177/0284185119891417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND According to the as low as reasonably achievable (ALARA) principle, radiation exposure in computed tomography (CT) should be minimized while maintaining adequate image quality. Dedicated CT protocols combined with iterative reconstruction (IR) can reduce radiation dose and/or improve image quality. PURPOSE To investigate the feasibility of extremely reduced-dose (RD) CT of the thoracic spine in human cadavers using a standard-dose (SD) and three different RDCT protocols reconstructed with filtered back projection (FBP) and IR. MATERIAL AND METHODS The thoracic spines of 11 cadavers were examined using different RDCT protocols with decreasing reference tube currents (RDCT-1: 50 mAs; RDCT-2: 30 mAs; RDCT-3: 10 mAs) at 140 kV. A clinical SDCT (70 mAs, 140 kV) served as reference. Raw data were reconstructed using FBP and two increasing levels of IR (IRL4 and IRL6). Images were evaluated for image quality, diagnostic acceptability, and visibility of anatomical structures according to a 5-point-scale. RESULTS Regardless of the reconstruction technique, image quality was rated as diagnostically acceptable for all cadavers in SDCT and RDCT-1. Image quality of reconstructions with FBP were generally rated lower. Application of IR improved image quality ratings in SDCT and RDCT. RDCT-2 with IR was the most reduced-dose CT protocol which enabled diagnostically acceptable image quality in all cadavers. Compared to SDCT, RDCT protocols resulted in significantly reduced effective radiation doses (SDCT: 4.1 ± 1.5 mSv; RDCT-1: 2.9 ± 1.1 mSv; 2:1.7 ± 0.6 mSv; 3:0.6 ± 0.1 mSv; P = 0.001). CONCLUSION Diagnostically acceptable RDCT of the thoracic spine with 1.7 mSv is feasible using IR.
Collapse
Affiliation(s)
- Julius Matthias Weinrich
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Malte Warncke
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Nis Wiese
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Marc Regier
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Enver Tahir
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Axel Heinemann
- Department of Legal Medicine, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Susanne Sehner
- Department of Medical Biometry and Epidemiology, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Klaus Püschel
- Department of Legal Medicine, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Gerhard Adam
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| | - Azien Laqmani
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
295
|
Messina C, Albano D, Gitto S, Tofanelli L, Bazzocchi A, Ulivieri FM, Guglielmi G, Sconfienza LM. Body composition with dual energy X-ray absorptiometry: from basics to new tools. Quant Imaging Med Surg 2020; 10:1687-1698. [PMID: 32742961 DOI: 10.21037/qims.2020.03.02] [Citation(s) in RCA: 115] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Dual-energy X-ray absorptiometry (DXA) in nowadays considered one of the most versatile imaging techniques for the evaluation of metabolic bone disorders such as osteoporosis, sarcopenia and obesity. The advantages of DXA over other imaging techniques are the very low radiation dose, its accuracy and simplicity of use. In addition, fat mass (FM) and lean mass (LM) values by DXA shows very good accuracy compared to that of computed tomography and magnetic resonance imaging. In this review we will explain the technical working principles of body composition with DXA, together with the possible limitations and pitfalls that should be avoided in daily routine to produce high-quality DXA examinations. We will also cover the current clinical practical application of whole body DXA values, with particular emphasis on the use of LM indices in the diagnostic workup of reduced muscle mass, sarcopenia and osteosarcopenic obesity according to the most recent guidelines. The possible use of adipose indices will be considered, such as the fat mass index (FMI) or the android/gynoid ratio, as well as lipodystrophy indices and the evaluation of visceral adipose tissue (VAT). Whenever available, we will provide possible cut-off diagnostic values for each of these LM and FM indices, according to current literature and guidelines.
Collapse
Affiliation(s)
- Carmelo Messina
- IRCCS Istituto Ortopedico Galeazzi, Via Riccardo Galeazzi 4, 20161 Milano, Italy.,Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Luigi Mangiagalli 31, 20133, Milano, Italy
| | - Domenico Albano
- IRCCS Istituto Ortopedico Galeazzi, Via Riccardo Galeazzi 4, 20161 Milano, Italy.,Sezione di Scienze Radiologiche, Dipartimento di Biomedicina, Neuroscienze e Diagnostica Avanzata, Università degli Studi di Palermo, 90127, Palermo, Italy
| | - Salvatore Gitto
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Luigi Mangiagalli 31, 20133, Milano, Italy
| | - Laura Tofanelli
- Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milano, Italy
| | - Alberto Bazzocchi
- Diagnostic and Interventional Radiology, IRCCS Istituto Ortopedico Rizzoli, Via G. C. Pupilli 1, 40136, Bologna, Italy
| | - Fabio Massimo Ulivieri
- Bone Metabolic Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico. Medicina Nucleare, Via Francesco Sforza 35, 20122, Milano, Italy
| | - Giuseppe Guglielmi
- Department of Radiology, University of Foggia, Viale Luigi Pinto 1, 71100, Foggia, Italy.,Department of Radiology, Scientific Institute "Casa Sollievo della Sofferenza" Hospital, San Giovanni Rotondo, Foggia, Italy
| | - Luca Maria Sconfienza
- IRCCS Istituto Ortopedico Galeazzi, Via Riccardo Galeazzi 4, 20161 Milano, Italy.,Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Luigi Mangiagalli 31, 20133, Milano, Italy
| |
Collapse
|
296
|
Shim YS, Park SH, Choi SJ, Ahn SJ, Pak SY, Jung H, Park SH. Comparison of submillisievert CT with standard-dose CT for urolithiasis. Acta Radiol 2020; 61:1105-1115. [PMID: 31795730 DOI: 10.1177/0284185119890088] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
BACKGROUND Patients with renal stones receive multiple computed tomography (CT) examinations. We investigated whether submillisievert (sub-mSv) CT for stone detection could reduce radiation dose at exposure levels comparable to kidney, ureter, and bladder (KUB) radiography. PURPOSE To evaluate the radiation dose exposure, diagnostic performance, and image quality of sub-mSv non-contrast CT using advanced modelled iterative reconstruction algorithm with spectral filtration for the detection of urolithiasis. MATERIAL AND METHODS A total of 145 consecutive patients underwent non-contrast CT using a third-generation dual-source scanner to obtain two datasets, i.e. 16.7% (sub-mSv CT, tube detector A) and 100% (standard-dose CT, combination of tube detector A and B) tube loads with spectral filtration. The performance of sub-mSv CT for the detection of stones was analyzed by two readers and compared with that of standard-dose CT. Image quality was measured subjectively and objectively. RESULTS In total, 171 stones were detected in 79 patients. The mean effective radiation doses of sub-mSv CT was 0.3 mSv. The sensitivity and specificity values for diagnosis of stones measuring ≥3 mm was 95.1% and 100% for sub-mSv CT. The sensitivity and specificity for all stone detection was 74.9% and 97.8%, respectivey, for sub-mSv CT. The image quality was lower for sub-mSv CT than for standard-dose CT (P < 0.01). CONCLUSION Sub-mSv CT can be achieved with radiation doses close to KUB radiography. Sub-mSv CT with spectral filtration can be used to detect stones measuring ≥3 mm and be used as a follow-up imaging modality as an alternative to KUB radiography.
Collapse
Affiliation(s)
- Young Sup Shim
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
| | - So Hyun Park
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
| | - Seung Joon Choi
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
| | - Su Joa Ahn
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
| | - Seong Yong Pak
- Healthcare Diagnostic Imaging Division, Siemens-healthineers, Seoul, Republic of Korea
| | - Han Jung
- Department of Urology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
| | - Seong Ho Park
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea
| |
Collapse
|
297
|
Schultheiss M, Schober SA, Lodde M, Bodden J, Aichele J, Müller-Leisse C, Renger B, Pfeiffer F, Pfeiffer D. A robust convolutional neural network for lung nodule detection in the presence of foreign bodies. Sci Rep 2020; 10:12987. [PMID: 32737389 PMCID: PMC7395787 DOI: 10.1038/s41598-020-69789-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 07/14/2020] [Indexed: 12/24/2022] Open
Abstract
Lung cancer is a major cause of death worldwide. As early detection can improve outcome, regular screening is of great interest, especially for certain risk groups. Besides low-dose computed tomography, chest X-ray is a potential option for screening. Convolutional network (CNN) based computer aided diagnosis systems have proven their ability of identifying nodules in radiographies and thus may assist radiologists in clinical practice. Based on segmented pulmonary nodules, we trained a CNN based one-stage detector (RetinaNet) with 257 annotated radiographs and 154 additional radiographs from a public dataset. We compared the performance of the convolutional network with the performance of two radiologists by conducting a reader study with 75 cases. Furthermore, the potential use for screening on patient level and the impact of foreign bodies with respect to false-positive detections was investigated. For nodule location detection, the architecture achieved a performance of 43 true-positives, 26 false-positives and 22 false-negatives. In comparison, performance of the two readers was 42 ± 2 true-positives, 28 ± 0 false-positives and 23 ± 2 false-negatives. For the screening task, we retrieved a ROC AUC value of 0.87 for the reader study test set. We found the trained RetinaNet architecture to be only slightly prone to foreign bodies in terms of misclassifications: out of 59 additional radiographs containing foreign bodies, false-positives in two radiographs were falsely detected due to foreign bodies.
Collapse
Affiliation(s)
- Manuel Schultheiss
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany.
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, 81675, München, Germany.
| | - Sebastian A Schober
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany
| | - Marie Lodde
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, 81675, München, Germany
| | - Jannis Bodden
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, 81675, München, Germany
| | - Juliane Aichele
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, 81675, München, Germany
| | - Christina Müller-Leisse
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, 81675, München, Germany
| | - Bernhard Renger
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, 81675, München, Germany
| | - Franz Pfeiffer
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, 81675, München, Germany
| | - Daniela Pfeiffer
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, 81675, München, Germany
| |
Collapse
|
298
|
Patel S. The effects of microgravity and space radiation on cardiovascular health: From low-Earth orbit and beyond. IJC HEART & VASCULATURE 2020; 30:100595. [PMID: 32775602 PMCID: PMC7399104 DOI: 10.1016/j.ijcha.2020.100595] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 07/07/2020] [Accepted: 07/13/2020] [Indexed: 10/26/2022]
Abstract
The unique conditions of space harbor considerable challenges for astronauts to overcome. Namely, the ionizing content of space radiation and the effects of microgravity have been implicated in the pathogenesis of cardiovascular disease. Post-flight carotid arterial stiffness was demonstrated in astronaut studies while early arteriosclerosis has been linked with microgravity-induced oxidative stress in cellular studies. Similarly, radiation has been shown to disrupt molecular pathways, enhance reactive oxygen species and increase risk of cardiovascular disease in exposed populations. These results may bear even more significance in space owing to the propensity for microgravity and space radiation to yield synergistic and/or additive interactions. Potential countermeasures such as α-tocopherol and captopril target these oxidative pathways and may help to protect against the effects of microgravity and radiation-induced cardiac damage. However, more research needs to be conducted in this area to facilitate a safe passage for humans to the Moon, Mars and beyond.
Collapse
Affiliation(s)
- Smit Patel
- Vascular Biology, Cardiovascular Science, National Heart & Lung Institute (NHLI), Faculty of Medicine, Imperial College London, Dovehouse Street, London SW3 6LY, UK
| |
Collapse
|
299
|
Corso M, Cancelliere C, Mior S, Kumar V, Smith A, Côté P. The clinical utility of routine spinal radiographs by chiropractors: a rapid review of the literature. Chiropr Man Therap 2020; 28:33. [PMID: 32641135 PMCID: PMC7346665 DOI: 10.1186/s12998-020-00323-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Accepted: 05/24/2020] [Indexed: 02/08/2023] Open
Abstract
INTRODUCTION When indicated by signs or symptoms of potentially serious underlying pathology (red flags), chiropractors can use radiographs to inform their diagnosis. In the absence of red flags, the clinical utility of routine or repeat radiographs to assess the structure and function of the spine is controversial. OBJECTIVES To determine the diagnostic and therapeutic utility of routine or repeat radiographs (in the absence of red flags) of the cervical, thoracic or lumbar spine for the functional or structural evaluation of the spine. Investigate whether functional or structural findings on repeat radiographs are valid markers of clinically meaningful outcomes. The research objectives required that we determine the validity, diagnostic accuracy and reliability of radiographs for the structural and functional evaluation of the spine. EVIDENCE REVIEW We searched MEDLINE, CINAHL, and Index to Chiropractic Literature from inception to November 25, 2019. We used rapid review methodology recommended by the World Health Organization. Eligible studies (cross-sectional, case-control, cohort, randomized controlled trials, diagnostic and reliability) were critically appraised. Studies of acceptable quality were included in our synthesis. The lead author extracted data and a second reviewer independently validated the data extraction. We conducted a qualitative synthesis of the evidence. FINDINGS We identified 959 citations, screened 176 full text articles and critically appraised 23. No relevant studies assessed the clinical utility of routine or repeat radiographs (in the absence of red flags) of the cervical, thoracic or lumbar spine for the functional or structural evaluation of the spine. No studies investigated whether functional or structural findings on repeat radiographs are valid markers of clinically meaningful outcomes. Nine low risk of bias studies investigated the validity (n = 2) and reliability (n = 8) of routine or repeat radiographs. These studies provide no evidence of clinical utility. CONCLUSION We found no evidence that the use of routine or repeat radiographs to assess the function or structure of the spine, in the absence of red flags, improves clinical outcomes and benefits patients. Given the inherent risks of ionizing radiation, we recommend that chiropractors do not use radiographs for the routine and repeat evaluation of the structure and function of the spine.
Collapse
Affiliation(s)
- Melissa Corso
- Faculty of Health Sciences, Ontario Tech University and Centre for Disability Prevention and Rehabilitation, 2000 Simcoe St N, Oshawa, ON, L1G 0C5, Canada
| | - Carol Cancelliere
- Faculty of Health Sciences, Ontario Tech University and Centre for Disability Prevention and Rehabilitation, 2000 Simcoe St N, Oshawa, ON, L1G 0C5, Canada
| | - Silvano Mior
- Faculty of Health Sciences, Ontario Tech University and Centre for Disability Prevention and Rehabilitation, 2000 Simcoe St N, Oshawa, ON, L1G 0C5, Canada
- Canadian Memorial Chiropractic College, North York, Ontario, Canada
| | - Varsha Kumar
- Canadian Memorial Chiropractic College, North York, Ontario, Canada
| | - Ali Smith
- Canadian Memorial Chiropractic College, North York, Ontario, Canada
| | - Pierre Côté
- Faculty of Health Sciences, Ontario Tech University and Centre for Disability Prevention and Rehabilitation, 2000 Simcoe St N, Oshawa, ON, L1G 0C5, Canada.
| |
Collapse
|
300
|
Hopkins SR. Ventilation/Perfusion Relationships and Gas Exchange: Measurement Approaches. Compr Physiol 2020; 10:1155-1205. [PMID: 32941684 DOI: 10.1002/cphy.c180042] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Ventilation-perfusion ( V ˙ A / Q ˙ ) matching, the regional matching of the flow of fresh gas to flow of deoxygenated capillary blood, is the most important mechanism affecting the efficiency of pulmonary gas exchange. This article discusses the measurement of V ˙ A / Q ˙ matching with three broad classes of techniques: (i) those based in gas exchange, such as the multiple inert gas elimination technique (MIGET); (ii) those derived from imaging techniques such as single-photon emission computed tomography (SPECT), positron emission tomography (PET), magnetic resonance imaging (MRI), computed tomography (CT), and electrical impedance tomography (EIT); and (iii) fluorescent and radiolabeled microspheres. The focus is on the physiological basis of these techniques that provide quantitative information for research purposes rather than qualitative measurements that are used clinically. The fundamental equations of pulmonary gas exchange are first reviewed to lay the foundation for the gas exchange techniques and some of the imaging applications. The physiological considerations for each of the techniques along with advantages and disadvantages are briefly discussed. © 2020 American Physiological Society. Compr Physiol 10:1155-1205, 2020.
Collapse
Affiliation(s)
- Susan R Hopkins
- Departments of Medicine and Radiology, University of California, San Diego, California, USA
| |
Collapse
|