351
|
Veilleux NJ, Kalore NV, Wegelin JA, Vossen JA, Jiranek WA, Wayne JS. Automated femoral version estimation without the distal femur. J Orthop Res 2018; 36:3161-3168. [PMID: 30074280 DOI: 10.1002/jor.24121] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2018] [Accepted: 07/16/2018] [Indexed: 02/04/2023]
Abstract
Femoral version impacts the long-term functioning of the femoroacetabular joint. Accurate measurements of version are thus required for success in total hip arthroplasties and hip reconstructive surgeries. These are impossible to obtain without visualization of the distal femur, which is often unavailable preoperatively as the majority of imaging scans are isolated to the pelvis and proximal femur. We developed an automated algorithm for identifying the major landmarks of the femur. These landmarks were then used to identify proximal axes and create a statistical shape model of the proximal femur across 144 asymptomatic femora. With six proximal axes selected, and 200 parameters (distances and angles between points) from the shape model measured, the best-fitting linear correlation was found. The difference between true version and version predicted by this model was 0.00 ± 5.13° with a maximum overestimation and underestimation of 11.80 and 15.35°, respectively. The mean absolute difference was 4.14°. This model and its prediction of femoral version are a substantial improvement over pre-operative 2D or intra-operative visual estimation measures. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:3161-3168, 2018.
Collapse
Affiliation(s)
- Nathan J Veilleux
- Orthopaedic Research Laboratory, Department of Biomedical Engineering, Virginia Commonwealth University, P.O. Box 843067, Richmond, Virginia
| | - Niraj V Kalore
- Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, Virginia
| | - Jacob A Wegelin
- Department of Biostatistics, Virginia Commonwealth University, Richmond, Virginia
| | - Josephina A Vossen
- Department of Radiology, Virginia Commonwealth University, Richmond, Virginia
| | - William A Jiranek
- Department of Orthopaedic Surgery, Duke University, Durham, North Carolina
| | - Jennifer S Wayne
- Orthopaedic Research Laboratory, Department of Biomedical Engineering, Virginia Commonwealth University, P.O. Box 843067, Richmond, Virginia
| |
Collapse
|
352
|
Peng Y, Arauz P, An S, Kwon YM. In vivo sliding distance on the metal-on-polyethylene total hip arthroplasty articulation using patient-specific gait analysis. J Orthop Res 2018; 36:3151-3160. [PMID: 30035328 DOI: 10.1002/jor.24113] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 07/13/2018] [Indexed: 02/04/2023]
Abstract
Metal-on-polyethylene (MoP) is the most commonly used bearing surface in primary total hip arthroplasty (THA). Polyethylene wear debris remains a major concern. Studies investigating the wear performance based on patient-specific in vivo kinematics and component orientation remains largely lacking. The primary goal of this study was to identify patterns of the distribution of sliding distance and cross-shear ratio among THA patients. A validated approach combining dual fluoroscopic imaging system and computed-tomography was utilized to quantify in vivo gait kinematics and component orientations in 48 total hips. The distribution of accumulated sliding distance and cross-shear ratio over the polyethylene bearing surface was calculated and analyzed using principal component analysis (PCA). Strong patient-specific variation in sliding distance and cross-shear ratio was observed. PCA detected two principal components (PCs) of the sliding distance that together contribute to 94.8% of the total variation. PCA detected four PCs that together contribute to 86% of the total variation of the cross-shear ratio. Regression analysis identified a positive association between cross-shear magnitude and axial and frontal range of motion (RoM). Increased cup inclination, stem anteversion, and reduced cup anteversion may lead to superiorly distributed high cross-shear region, potentially accelerating wear. Our study investigated, in vivo sliding distance and cross-shear pattern using a comprehensive patient-specific dataset and detected several wear indicators under in vivo conditions. These findings provided useful reference values that may help to assess wear in MoP THA patients. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:3151-3160, 2018.
Collapse
Affiliation(s)
- Yun Peng
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts
| | - Paul Arauz
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts
| | - Shuai An
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts
| | - Young-Min Kwon
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts
| |
Collapse
|
353
|
Lum ZC, Dorr LD. Restoration of center of rotation and balance of THR. J Orthop 2018; 15:992-996. [PMID: 30224857 PMCID: PMC6138845 DOI: 10.1016/j.jor.2018.08.040] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Accepted: 08/25/2018] [Indexed: 10/28/2022] Open
Abstract
Improvements in early hip arthroplasties focused on surgical techniques with subsequent studies emphasizing restoration of the hip center of rotation for longevity of the implant. Current literature suggests femoral stem anteversion of 10-20°, cup anteversion of 20-25° and a combined anteversion of 25-40° in males, 30-45° in females. Inclination goal appears to be 45° precisely to balance between impingement & dislocation versus edge loading & accelerated wear. Restoration of the acetabular center of rotation will improve joint reactive forces and reduce wear. Here we describe techniques to achieve a well balanced total hip with restoration of the center of rotation.
Collapse
Affiliation(s)
- Zachary C. Lum
- University of California, Davis Medical Center, Department of Orthopaedics, 4860 Y Street, Suite 3800, Sacramento, CA, 95817, USA
| | - Lawrence D. Dorr
- Keck Medical Center of University of Southern California, 1520 San Pablo Street, Suite 2000, Department of Orthopedics, Los Angeles, CA, 90033, USA
| |
Collapse
|
354
|
Shigemura T, Yamamoto Y, Murata Y, Sato T, Tsuchiya R, Mizuki N, Toki Y, Wada Y. Total hip arthroplasty after failed transtrochanteric rotational osteotomy for osteonecrosis of the femoral head: A systematic review and meta-analysis. Orthop Traumatol Surg Res 2018; 104:1163-1170. [PMID: 30293751 DOI: 10.1016/j.otsr.2018.06.019] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Revised: 05/16/2018] [Accepted: 06/08/2018] [Indexed: 02/02/2023]
Abstract
BACKGROUND Several studies have reported regarding total hip arthroplasty (THA) for osteonecrosis of the femoral head after failed transtrochanteric rotational osteotomy (TRO). However, to our knowledge, no formal systematic review and meta-analysis have been published yet summarizing the clinical results of a THA after failed TRO. Therefore, we conducted a systematic review and meta-analysis of the THA outcomes after failed TRO. We focussed on the issue whether a previous TRO affects the results of subsequent THA, including operative time, operative blood loss, radiological parameters, postoperative complications, and clinical outcomes. METHODS Literatures published up to January 2018 were searched in the PubMed, Web of Science, and Cochrane Library, and the pooling of data was performed using a RevMan software (version 5.3, Cochrane Collaboration, Oxford, UK). A p-value<0.05 was considered statistically significant. We calculated the mean differences (MD) for continuous data and the odds ratio (OR) for dichotomous data with 95% confidence intervals (CI) for each outcome. Statistical heterogeneity was assessed based on I2 using the standard Chi2. When I2>50%, significant heterogeneity was assumed, and a random-effects model was applied for the meta-analysis. A fixed-effects model was applied in the absence of significant heterogeneity. RESULTS Five studies were included in this meta-analysis. The results showed that operative time was significantly longer in the THA after the TRO than that for the THA without previous osteotomy (I2=92%; MD=31.62; 95% CI: 5.95 to 57.28; p=0.02). Operative blood loss was significantly greater in the THA after the TRO than that in the THA without previous osteotomy (I2=71%; MD=123.30; 95% CI: 22.21 to 224.39; p=0.02). The rate of stem malalignment was significantly higher in the THA after the TRO than that in the THA without previous osteotomy (I2=0%; OR=5.23, 95% CI: 1.95 to 14.06; p=0.001). There was no significant difference in the dislocation rate (I2=0%; OR=2.12; 95% CI: 0.64 to 6.99; p=0.22), and the postoperative Harris hip score at the final follow-up (I2=75%, MD=-0.46, 95% CI: -3.92 to 3.01, p=0.80) between the groups. CONCLUSION The results demonstrate that, performing the THA after the TRO is technically more demanding than the THA without previous osteotomy. TRO does not affect the clinical results of future THA, and is a sufficient therapeutic alternative in younger patients. LEVEL OF EVIDENCE III, systematic and meta-analysis of case control studies.
Collapse
Affiliation(s)
- Tomonori Shigemura
- Department of Orthopaedic Surgery, Teikyo University Chiba Medical Center, 3426-3 Anesak, Ichiharai, Chiba 299-0111, Japan.
| | - Yohei Yamamoto
- Department of Orthopaedic Surgery, Teikyo University Chiba Medical Center, 3426-3 Anesak, Ichiharai, Chiba 299-0111, Japan
| | - Yasuaki Murata
- Department of Orthopaedic Surgery, Teikyo University Chiba Medical Center, 3426-3 Anesak, Ichiharai, Chiba 299-0111, Japan
| | - Takashi Sato
- Department of Orthopaedic Surgery, Teikyo University Chiba Medical Center, 3426-3 Anesak, Ichiharai, Chiba 299-0111, Japan
| | - Ryuto Tsuchiya
- Department of Orthopaedic Surgery, Teikyo University Chiba Medical Center, 3426-3 Anesak, Ichiharai, Chiba 299-0111, Japan
| | - Norichika Mizuki
- Department of Orthopaedic Surgery, Chiba Rosai Hospital, 2-16 Tatsumidai-higashi, Ichihara, Chiba 290-0003, Japan
| | - Yasunori Toki
- Department of Orthopaedic Surgery, Kimitsu Chuo Hospital, 1010 Sakurai, Kisarazu, Chiba 292-0822, Japan
| | - Yuichi Wada
- Department of Orthopaedic Surgery, Teikyo University Chiba Medical Center, 3426-3 Anesak, Ichiharai, Chiba 299-0111, Japan
| |
Collapse
|
355
|
Luo Y, Sun XF, Chen J, Cui W, Wang T. Could larger diameter of 4th generation ceramic bearing increase the rate of squeaking after THA?: A retrospective study. Medicine (Baltimore) 2018; 97:e13977. [PMID: 30593224 PMCID: PMC6314778 DOI: 10.1097/md.0000000000013977] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The present study aimed to evaluate the clinical outcomes and bearing-specific complications in a single center of 135 delta ceramic-on-ceramic (COC) total hip arthroplasties (THAs) and explore the occurrence rate of squeaking in 4th generation COC THAs and collate the risk factors for squeaking.We retrospectively analyzed consecutive cohorts of 127 patients (135 hips) who had primary THA with delta COC bearings in our hospital between April 2010 and April 2012. Preoperative Harris hip score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and University of California Los Angeles (UCLA) activity score were evaluated preoperatively and postoperatively. We also evaluated ceramic fracture, squeak, mid-term results, and survival.In our study, the final patient final follow-up date was July 31, 2016. The mean preoperative HHS improved from 39.5 to 93.1 points. Mean preoperative UCLA score was 3.2 points, improving to 8.2 points. The mean preoperative total WOMAC score was 55.5 points and the mean total WOMAC score was 13.3 points at the final follow-up. The Kaplan-Meier survival plot of revision for any reason as the end point was 98.5% and survival with ceramic fracture as the end point was 99.2% at a mean of 70 months' follow-up. One post-operative ceramic liner rim fracture occurred at 50 months after surgery. Thirteen of the 135 hips produced a squeaking sound. There were no significant differences in gender (P = .56), age (P = .20), body mass index (BMI) (P = .11), diagnosis (P = .46), cup inclination (P = .36), or cup anteversion (P = 1.0) between the squeaking and non-squeaking groups. However, the incidence of squeaking in the 36 mm COC femoral head bearings was higher than in the 28 mm size (13.6% vs 2.1%, P = .033).The 4th generation COC bearing performed well and provides an encouraging rate of survival with no osteolysis or loosening. However, we found that a squeaking sound associated with use of the delta ceramic occurred at a rate of 9.6%, with the larger-diameter heads having significantly higher incidence.
Collapse
Affiliation(s)
- Yuan Luo
- Department of Orthopedic Surgery, The First People's Hospital of Taicang
| | - Xue-Feng Sun
- Department of Orthopedic Surgery, Suzhou Xiangcheng People's Hospital
| | - Jin Chen
- Department of Orthopedic Surgery, Suzhou Xiangcheng People's Hospital
| | - Wei Cui
- Department of Orthopedic Surgery, Suzhou Xiangcheng People's Hospital
| | - Tao Wang
- Department of Orthopedic Surgery, Affiliated Hospital of Jiangnan University, Wuxi, China
| |
Collapse
|
356
|
Zhou B, Zhou Y, Yang D, Tang H, Shao H, Huang Y. The Utilization of Metal Augments Allows Better Biomechanical Reconstruction of the Hip in Revision Total Hip Arthroplasty With Severe Acetabular Defects: A Comparative Study. J Arthroplasty 2018; 33:3724-3733. [PMID: 30243881 DOI: 10.1016/j.arth.2018.08.027] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Revised: 08/22/2018] [Accepted: 08/24/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Reconstructing the normal hip biomechanics is important for a successful revision total hip arthroplasty (THA). Little is known about whether using metal augments in revision THA is biomechanically superior to traditional techniques. METHODS A retrospective review was conducted on 74 consecutive THAs revised using metal augments with a cementless hemispherical cup and 77 consecutive THAs revised using the jumbo cup, all with a minimum 2-year follow-up. Biomechanical parameters were measured before and immediately after the revision. Radiological and clinical outcomes at follow-ups were also evaluated. RESULTS The metal augment group had a reconstructed center of rotation (COR) that was 6.5 mm closer to the anatomic COR in height (P < .001), had 3.6 m smaller cup size (P < .001), and had 5.7 mm less head-cup difference (P < .001). Moreover, there was a reconstructed COR that was much closer to the anatomic COR (vertical distance: 1.8 vs 14.1 mm, P < .001; horizontal distance: -2.1 vs 7.9 mm, P = .013), had 4.1 mm greater femoral offset (P = .006), and had 8 mm less leg length discrepancy (P = .035) in the subgroup of Paprosky type III bone defects when compared to the jumbo cup group. All cup-augment constructs were radiologically stable with a higher mean postoperative Harris Hip Score (P = .012). One jumbo cup was radiologically unstable. CONCLUSION In revision THA, utilizing metal augments helps to restore the COR position more precisely, avoid using a larger cup, reduce head-cup difference, rebuild femoral offset, and decrease leg length discrepancy, particularly with Paprosky type III bone defects. Moreover, it provides satisfactory radiological and clinical outcomes in the short term.
Collapse
Affiliation(s)
- Baochun Zhou
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, People's Republic of China
| | - Yixin Zhou
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, People's Republic of China
| | - Dejin Yang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, People's Republic of China
| | - Hao Tang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, People's Republic of China
| | - Hongyi Shao
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, People's Republic of China
| | - Yong Huang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, People's Republic of China
| |
Collapse
|
357
|
Imai H, Miyawaki J, Kamada T, Maruishi A, Takeba J, Miura H. Radiolucency around highly porous sockets and hydroxyapatite-coated porous sockets in total hip arthroplasty for hip dysplasia. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2018; 29:611-618. [PMID: 30488136 PMCID: PMC6422951 DOI: 10.1007/s00590-018-2351-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Accepted: 11/25/2018] [Indexed: 02/07/2023]
Abstract
Studies over the past decade have reported that the use of highly porous sockets in total hip arthroplasty (THA) results in osseointegration and long-term implant stability. However, some reports have raised concerns regarding radiographic evidence of poor osseointegration with features of fibrous tissue ingrowth. The purpose of this study was to compare clinical and radiographic assessments of highly porous sockets with those of hydroxyapatite (HA)-coated porous sockets in THA for hip dysplasia (DDH) at least 1 year after surgery. A total of 127 patients (136 hips) were recruited for the study. Of these, 94 patients (101 hips) received highly porous sockets with clustered screws, while 33 patients (35 hips) received HA-coated porous sockets with clustered screws. There was no difference in clinical outcomes between the two types of sockets. All HA-coated porous sockets were radiographically stable, without radiolucent lines. Fifteen hips had radiolucent lines in two or three DeLee and Charnley zones, accompanied by sclerotic lines along the circumferences of the highly porous sockets. A significant difference in the height of the preoperative osteophyte of the anterior acetabular wall was observed between 86 hips with one or no radiolucent lines and 15 hips with two or three radiolucent lines. In cases of DDH with atrophic bone remodeling pattern, highly porous sockets with multiple screws may be used, while HA-coated porous sockets with clustered screws result in better sealing of the bone–component interface.
Collapse
Affiliation(s)
- Hiroshi Imai
- Department of Bone and Joint Surgery, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
| | - Joji Miyawaki
- Department of Bone and Joint Surgery, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Tomomi Kamada
- Department of Bone and Joint Surgery, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Akira Maruishi
- Department of Bone and Joint Surgery, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Jun Takeba
- Department of Bone and Joint Surgery, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| | - Hiromasa Miura
- Department of Bone and Joint Surgery, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan
| |
Collapse
|
358
|
Schulze C, Vogel D, Sander M, Bader R. Calibration of crushable foam plasticity models for synthetic bone material for use in finite element analysis of acetabular cup deformation and primary stability. Comput Methods Biomech Biomed Engin 2018; 22:25-37. [PMID: 30449160 DOI: 10.1080/10255842.2018.1524884] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Polyurethane (PU) foam is a material often used in biomechanical experiments and demands for the definition of crushable foam plasticity (CFP) in numerical simulations of the primary stability and deformation of implants, to describe the crushing behaviour appropriately. Material data of PU foams with five different densities (10-40 pounds per cubic foot were ascertained experimentally in uniaxial compression test and used to calibrate CFP models for finite element modelling. Additionally, experimental and numerical deformation, push-out and lever-out tests of press-fit acetabular cups were carried out to assess the influence of the chosen material definition (linear elastic and CFP) on the numerical results. Comparison of the experimentally and numerically determined force-displacement curves of the uniaxial compression test showed a mean deviation of less than 3%. In primary stability testing, the deviation between the experimental and numerical results was in a range of 0%-27% for CFP modelling and 64%-341% for the linear elastic model. The material definition selected, highly influenced the numerical results in the current study. The use of a CFP model is recommended for further numerical simulations, when a deformation of the foam beyond the yield strength is likely to occur.
Collapse
Affiliation(s)
- Christian Schulze
- a Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics , University Medicine Rostock , Rostock , Germany
| | - Danny Vogel
- a Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics , University Medicine Rostock , Rostock , Germany
| | - Manuela Sander
- b Department of Structural Mechanics , University of Rostock , Rostock , Germany
| | - Rainer Bader
- a Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics , University Medicine Rostock , Rostock , Germany
| |
Collapse
|
359
|
Worlicek M, Weber M, Wörner M, Schwarz T, Zeman F, Grifka J, Renkawitz T, Craiovan B. The final implant position of a commonly used collarless straight tapered stem design (Corail ®) does not correlate with femoral neck resection height in cement-free total hip arthroplasty: a retrospective computed tomography analysis. J Orthop Traumatol 2018; 19:20. [PMID: 30426269 PMCID: PMC6233230 DOI: 10.1186/s10195-018-0513-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2018] [Accepted: 10/20/2018] [Indexed: 11/11/2022] Open
Abstract
Background In total hip arthroplasty, inadequate femoral component positioning can be associated with instability, impingement and component wear and subsequently with patient dissatisfaction. In this study, we investigated the influence of femoral neck resection height on the final three-dimensional position of a collarless straight tapered stem (Corail®). We asked two questions—(1) is neck resection height correlated with version, tilt, and varus/valgus alignment of the femoral component, and (2) dependent on the resection height of the femoral neck, which area of the stem comes into contact with the femoral cortical bone? Materials and methods Three-dimensional computed tomography scans of 40 patients who underwent minimally invasive, cementless total hip arthroplasty were analyzed retrospectively. We analyzed the relationship between femoral neck resection height and three-dimensional alignment of the femoral implant, as well as the contact points of the implant with the femoral cortical bone. This investigation was approved by the local Ethics Commission (No.10-121-0263) and is a secondary analysis of a larger project (DRKS00000739, German Clinical Trials Register May-02-2011). Results Mean femoral neck resection height was 10.4 mm (± 4.8) (range 0–20.1 mm). Mean stem version was 8.7° (± 7.4) (range − 2° to 27.9°). Most patients had a varus alignment of the implant. The mean varus/valgus alignment was 1.5° (± 1.8). All 40 patients (100%) had anterior tilt of the implant with a mean tilt of 2.2° (± 1.6). Femoral neck resection height did not correlate with stem version, varus/valgus alignment, or tilt. Independent from femoral neck resection height, in most patients the implant had contact with the ventral and ventromedial cortical bone in the upper third (77.5%) and the middle third (52.5%). In the lower third, the majority of the implants had contact with the lateral and dorsolateral cortical bone (92.5%). Conclusion Femoral neck resection height ranging between 0 and 20.1 mm does not correlate with the final position of a collarless straight tapered stem design (Corail®). Level of evidence Level 3.
Collapse
Affiliation(s)
- Michael Worlicek
- Department of Trauma Surgery, University Medical Center Regensburg, University of Regensburg, Franz-Josef-Strauss-Allee 1, 93053, Regensburg, Germany.
| | - Markus Weber
- Department of Orthopedic Surgery, Asklepios Medical Center, University of Regensburg, Bad Abbach, Germany
| | - Michael Wörner
- Department of Orthopedic Surgery, Asklepios Medical Center, University of Regensburg, Bad Abbach, Germany
| | - Timo Schwarz
- Department of Orthopedic Surgery, Asklepios Medical Center, University of Regensburg, Bad Abbach, Germany
| | - Florian Zeman
- Center of Clinical Studies, University of Regensburg, Regensburg, Germany
| | - Joachim Grifka
- Department of Orthopedic Surgery, Asklepios Medical Center, University of Regensburg, Bad Abbach, Germany
| | - Tobias Renkawitz
- Department of Orthopedic Surgery, Asklepios Medical Center, University of Regensburg, Bad Abbach, Germany
| | - Benjamin Craiovan
- Department of Orthopedic Surgery, Asklepios Medical Center, University of Regensburg, Bad Abbach, Germany
| |
Collapse
|
360
|
Tanaka T, Takao M, Sakai T, Hamada H, Tanaka S, Sugano N. Variations in sagittal and coronal stem tilt and their impact on prosthetic impingement in total hip arthroplasty. Artif Organs 2018; 43:569-576. [PMID: 30412266 DOI: 10.1111/aor.13388] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 11/02/2018] [Accepted: 11/02/2018] [Indexed: 11/28/2022]
Abstract
Optimization of the combined anteversion of cup and stem has been emphasized to avoid prosthetic impingement in total hip arthroplasty (THA). However, no study has focused on the impact of variations in sagittal and coronal stem tilt against the whole femur on prosthetic range of motion. The purposes of the present study were a) to quantify the anatomical variation of sagittal and coronal tilt of the proximal canal axis against the femoral retrocondylar coordinate system, that is variation of sagittal and coronal stem tilt and b) to determine their impact on the zone of impingement-free cup position using computer simulation. Preoperative computed tomography images of 477 femurs from 409 consecutive patients who underwent THA using computed tomography-based computer navigation were stored. Virtual implantation of an anatomical stem was performed on the navigation workstation. The safe zone of the cup position with regard to prosthetic impingement was determined by motion simulation in the range of sagittal and coronal stem tilt of the subjects. The sagittal and coronal stem tilt varied by 10°, which was smaller than the stem anteversion variation. However, there was about 3 times the difference in the impingement-free zone of cup position in the ranges of sagittal and coronal stem tilt. The safe zone was significantly decreased by posterior tilt and valgus tilt of the stem. Range of motion simulation revealed that the variations in sagittal or coronal stem tilt significantly influenced the safe zone of the cup. In conclusion, although the variations in sagittal and coronal stem tilt against the femoral retrocondylar coordinate system were small, their impact on prosthetic impingement was significant.
Collapse
Affiliation(s)
- Takeyuki Tanaka
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Osaka, Japan.,Orthopaedic Surgery, Sensory and Motor System Medicine, Surgical Sciences, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Masaki Takao
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Takashi Sakai
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Hidetoshi Hamada
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Sakae Tanaka
- Orthopaedic Surgery, Sensory and Motor System Medicine, Surgical Sciences, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Nobuhiko Sugano
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
361
|
Effect of changing femoral head diameter on bony and prosthetic jumping angles. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2018; 29:625-632. [PMID: 30377824 DOI: 10.1007/s00590-018-2325-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Accepted: 10/21/2018] [Indexed: 10/28/2022]
Abstract
BACKGROUND In THA, using a larger femoral head can increase the oscillation angle and jumping distance. However, there have been no reports which indicate precisely how increasing the jumping distance leads to an increase in the angle from impingement to dislocation (jumping angle). In this study, we clarified the jumping angle of various head diameters and its relationship with pelvic morphology. METHODS Using a three-dimensional templating system, virtual THA and ROM simulations were performed in 82 patients. We investigated the distance between bony and prosthetic impingement points and the head centre and calculated the jumping angle for various head diameters. We measured various pelvic shapes and length to clarify the relationship between pelvic morphology and impingement distance. RESULTS Jumping angles were 7.7° ± 3.2°, 12.1° ± 1.6°, 15.4° ± 2.5° and 10.0° ± 3.0° with flexion, internal rotation with 90° flexion (IR), extension and external rotation (ER), respectively, when we used a 22-mm head diameter. Bony jumping angle increased about 0.5°, 0.8°, 1.0° and 0.7° per 2-mm increase in head diameter with flexion, IR, extension and ER. On the other hand, prosthetic jumping angle remained almost stable at about 31°. Impingement distance was related to pelvic morphology in all directions. Bony jumping angles differed with ROM; the biggest was seen with extension, followed by IR, ER and flexion. On the other hand, bony jumping angle was less than prosthetic jumping angle in all cases. CONCLUSION Bony jumping angles differed with ROM; the biggest was seen with extension, followed by IR, ER and flexion. Prosthetic impingement angles were stable. In addition, the bony jumping angle was less than the prosthetic jumping angle in all cases.
Collapse
|
362
|
Tanino H, Sato T, Nishida Y, Mitsutake R, Ito H. Hip stability after total hip arthroplasty predicted by intraoperative stability test and range of motion: a cross-sectional study. BMC Musculoskelet Disord 2018; 19:373. [PMID: 30322394 PMCID: PMC6190554 DOI: 10.1186/s12891-018-2289-y] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2018] [Accepted: 10/01/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Dislocation continues to be a common complication following total hip arthroplasty (THA). A larger intraoperative range of motion (ROM) is believed to minimize dislocation risk, and intraoperative stability tests have been used to assess the ROM. However, it is not clear whether or not intraoperative stability tests can predict hip stability after THA. It is also unclear which angles are required in intraoperative stability tests. We investigated the usefulness of intraoperative stability tests, and other risk factors to predict hip stability after THA. METHODS Patients operated by single surgeon at one hospital from June 2009 to December 2013 were evaluated. This study included 185 hips with 32 mm metal femoral head. The range of internal rotation with 90° hip flexion (IR angle) was measured as an intraoperative stability test. The variables studied as risk factors included age, height, weight, gender, cerebral dysfunction, preoperative diagnosis, history of previous hip surgery, and IR angle. RESULTS Mean IR angle was statistically different between patients with dislocation and patients without dislocation (59.5° vs 69.6°: p = 0.006). Cerebral dysfunction and a history of previous hip surgery were statistically related with prevalence of dislocation (p = 0.021, and p = 0.011). The receiver-operating characteristic curve analysis suggested that the cutoff points for IR angle were 51° and 67°. Dislocation rate in larger IR angle group was significantly lower than the rate in smaller IR angle group when patients were divided by 51° (p = 0.002). Logistic regression analyses showed that significant risk factors were cerebral dysfunction (OR: 5.3 (95%CI 1.1-25.9); p = 0.037), history of previous hip surgery (OR: 8.6 (95%CI 1.2-63.0); p = 0.035), and IR angle (OR: 10.4 (95%CI 1.9-57.1); p = 0.007). CONCLUSIONS The results showed that intraoperative stability test, especially the IR angle, was a useful method to predict hip stability after THA, and a larger intraoperative ROM reduced the likelihood of dislocation. 51° and 67° were indicated as cutoff points for IR angle. Cerebral dysfunction and a history of previous hip surgery are also risk factors for the incidence of dislocation after THA. TRIAL REGISTRATION This is a retrospective study, not a clinical trial defined by the World Health Organization (WHO).
Collapse
Affiliation(s)
- Hiromasa Tanino
- Department of Orthopaedic Surgery, Asahikawa Medical University, Midorigaoka-Higashi 2-1-1-1, Asahikawa, 078-8510, Japan.
| | - Tatsuya Sato
- Department of Orthopaedic Surgery, Asahikawa Medical University, Midorigaoka-Higashi 2-1-1-1, Asahikawa, 078-8510, Japan
| | - Yasuhiro Nishida
- Department of Orthopaedic Surgery, Asahikawa Medical University, Midorigaoka-Higashi 2-1-1-1, Asahikawa, 078-8510, Japan
| | - Ryo Mitsutake
- Department of Orthopaedic Surgery, Asahikawa Medical University, Midorigaoka-Higashi 2-1-1-1, Asahikawa, 078-8510, Japan
| | - Hiroshi Ito
- Department of Orthopaedic Surgery, Asahikawa Medical University, Midorigaoka-Higashi 2-1-1-1, Asahikawa, 078-8510, Japan
| |
Collapse
|
363
|
Patient-Specific Surgical Guide for Total Hip Arthroplasty. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2018. [PMID: 30306490 DOI: 10.1007/978-981-13-1396-7_23] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2024]
Abstract
Three-dimensional printing technique has been adapted for orthopedic surgery, and a patient-specific surgical guide (PSG) has been introduced as a convenient surgical instrument and implicated in the ideal positioning of the components, including acetabular and femoral components in total hip arthroplasty (THA). PSG is designed and manufactured based on preoperative imaging data, mainly computed tomography (CT) data. PSGs for implantation in THA are classified into three types: PSG for guidewire insertion, PSG for bone cutting, and PSG for bone reaming and implant fixation. PSG positioning accuracy depends on the PSG design and surgical preparation in contact area on the bone surface. PSGs for the acetabular component, for the conventional femoral component, and for the resurfacing femoral component have been clinically used. To achieve precise implantation, precise PSG setting needs and careful surgical preparation of soft tissues are important.
Collapse
|
364
|
Bullock MW, De Gregorio M, Danelson KA, Willey JS, Seem ME, Plate JF, Lang JE, Shields JS. Quantifying the force transmission through the pelvic joints during total hip arthroplasty: A pilot cadaveric study. Clin Biomech (Bristol, Avon) 2018; 58:69-73. [PMID: 30048857 DOI: 10.1016/j.clinbiomech.2018.07.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Revised: 06/26/2018] [Accepted: 07/19/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Total hip arthroplasty is one of the most successful and cost effective procedures in orthopedics. The purpose of this study is to investigate force transmission through the sacroiliac joint as a possible source of post-operative pain after total hip arthroplasty through the following three questions: Does the ipsilateral sacroiliac joint, contralateral sacroiliac joint, or pubic symphysis experience more force during placement? Does the larger mallet used to seat the implant generate a higher force? Does the specimen's bone density or BMI alter force transmission? METHODS A solid design acetabular component was impacted into five human cadaver pelves with intact soft tissues. The pressure at both sacroiliac joints and the pubic symphysis was measured during cup placement. This same procedure was replicated using an existing pelvis finite element model to use for comparison. FINDINGS The location of the peak force for each hammer strike was found to be specimen specific. The finite model results indicated the ipsilateral sacroiliac joint had the highest pressure and strain followed by the pubic symphysis over the course of the full simulation. The heft of the mallet and bone mineral density did not predict force values or locations. The largest median force was generated in extremely obese specimens. INTERPRETATION Contrary to previous ideas, it is highly unlikely that forces experienced at the pelvic joints are large enough to contribute post-operative pain during impaction of an acetabular component. These results indicate more force is conveyed to the pubic symphysis compared to the sacroiliac joints.
Collapse
Affiliation(s)
- Matthew W Bullock
- Department of Orthopaedic Surgery, Wake Forest School of Medicine, Winston-Salem, NC 27157-1050, USA.
| | | | - Kerry A Danelson
- Department of Orthopaedic Surgery, Wake Forest School of Medicine, Winston-Salem, NC 27157-1050, USA.
| | - Jeffery S Willey
- Department of Orthopaedic Surgery, Wake Forest School of Medicine, Winston-Salem, NC 27157-1050, USA.
| | - Michael E Seem
- Department of Orthopaedic Surgery, Wake Forest School of Medicine, Winston-Salem, NC 27157-1050, USA.
| | - Johannes F Plate
- Department of Orthopaedic Surgery, Wake Forest School of Medicine, Winston-Salem, NC 27157-1050, USA.
| | - Jason E Lang
- Blue Ridge Bone and Joint, 2585 Hendersonville Road, Arden, NC 28704, USA
| | - John S Shields
- Department of Orthopaedic Surgery, Wake Forest School of Medicine, Winston-Salem, NC 27157-1050, USA.
| |
Collapse
|
365
|
Mayeda BF, Haw JG, Battenberg AK, Schmalzried TP. Femoral-Acetabular Mating: The Effect of Femoral and Combined Anteversion on Cross-Linked Polyethylene Wear. J Arthroplasty 2018; 33:3320-3324. [PMID: 29970327 DOI: 10.1016/j.arth.2018.06.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Revised: 05/29/2018] [Accepted: 06/04/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Cross-linked polyethylene (XLPE) has generally low rates of wear and osteolysis at 10 years, but component position may become important with longer follow-up. At 5-13 years, neither acetabular component lateral opening angle nor version were significantly correlated to wear. In the present study, we analyzed the effects of femoral anteversion and combined anteversion on XLPE wear. METHODS Forty-two well-functioning primary total hip arthroplasties in 36 patients, performed by a single surgeon via a posterior approach, were followed for a minimum of 5 years (mean, 7.1 years; range, 5.0-10.3). All hips had a modular, XLPE liner with a ≥36-mm bearing. Femoral anteversion was measured on the modified Budin view. Wear was measured on radiographs using a validated, computer-assisted, edge-detection-based algorithm. The mean lateral opening angle was 40.4° (range, 22.6°-50.3°). The mean acetabular version was 19.1° (range, 11.3°-27.5°). Neither of these variables was significantly correlated to wear. Effects of femoral anteversion and combined anteversion on XLPE wear were assessed using linear and polynomial regression analysis. RESULTS Femoral anteversion (mean, 18.4°; range, 6.8°-30.7°) was significantly correlated to linear wear (mean, 0.06 mm/y; range, 0-0.16), showing an inverse parabolic relationship with the least wear occurring at 18.2° (P = .02). Combined anteversion (mean, 37.2°; range, 21.8°-54.3°) showed a similar significant relationship with the least wear at 38.1° (P < .001). Based on regression, combined anteversion between 24.6° and 50.4° resulted in linear wear rates less than 0.1 mm/y. CONCLUSION To the authors' knowledge, this is the first study to identify femoral anteversion as an independent factor influencing XLPE wear, with least wear occurring around 18°. At 5-10 years, average linear wear of XLPE is below 0.1 mm/y over a 25°-50° range of combined anteversion, with the least wear around 38°. Femoral-acetabular mating is a product of both components. Femoral component version and combined anteversion had a greater effect on wear than acetabular component lateral opening angle. Additional studies are warranted, but these results indicate that the sensitivity of wear studies is increased with version assessments.
Collapse
Affiliation(s)
- Brian F Mayeda
- Department of Orthopaedic Surgery, Harbor-UCLA Medical Center, Torrance, CA
| | - Jonathan G Haw
- Department of Orthopaedic Surgery, Harbor-UCLA Medical Center, Torrance, CA
| | | | | |
Collapse
|
366
|
Sakai T, Abe H, Nakamura N, Hamada H, Takao M, Sugano N. Differences in activities of daily living after hip arthroplasty among hip resurfacing, anterolateral THA, and posterolateral THA: a propensity score matched analysis. J Artif Organs 2018; 22:84-90. [PMID: 30251057 DOI: 10.1007/s10047-018-1069-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2018] [Accepted: 09/04/2018] [Indexed: 11/24/2022]
Abstract
The aim was to elucidate the differences in activities of daily living (ADL) after hip arthroplasty among hip resurfacing (HRA), anterolateral total hip arthroplasty (AL-THA), and posterolateral THA (PL-THA) patients after age, sex, body mass index, bilateral/unilateral hip arthroplasty, and postoperative duration were matched using propensity scores. A total of 673 hips from 540 consecutive patients who underwent hip arthroplasty were included. A self-completed questionnaire on preoperative and postoperative ADLs was administered during postsurgical visits at least ≥ 4 years postoperatively. Between HRA and PL-THA patients, the numbers of patients who performed heels-down squatting was significantly more in HRA than in PL-THA. Between AL-THA and PL-THA patients, there were significant differences in postoperative ADLs including bathing in a bathtub, riding on a train/bus, cutting toenails, bowing while straight sitting, heels-up/down squatting, riding on a bicycle, driving a car, and domestic travel. There were no significant differences in postoperative ADLs between ≥ 36 mm head and ≤ 32 mm head PL-THA patients, and between AL-THA and HRA patients. This propensity score matched study indicated that AL-THA and HRA patients were more active postoperatively than PL-THA patients.
Collapse
Affiliation(s)
- Takashi Sakai
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita, 565-0871, Japan.
| | - Hirohito Abe
- Department of Orthopaedic Surgery, Osaka-Minami National Hospital, 2-1, Kidohigashi-cho, Kawachinagano, 586-8521, Japan.
| | - Nobuo Nakamura
- Department of Orthopaedic Surgery, Kyowakai Hospital, 1-24-1, Kishibekita, Suita, 564-0001, Japan
| | - Hidetoshi Hamada
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita, 565-0871, Japan
| | - Masaki Takao
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita, 565-0871, Japan
| | - Nobuhiko Sugano
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita, 565-0871, Japan
| |
Collapse
|
367
|
Cho HM, Seo JW, Lee HJ, Kang KB, Kim JR, Wee HW. Mid-to long-term results of total hip arthroplasty after contralateral lower extremity amputation. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA 2018; 52:343-347. [PMID: 30097316 PMCID: PMC6204465 DOI: 10.1016/j.aott.2018.06.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2017] [Revised: 03/04/2018] [Accepted: 06/27/2018] [Indexed: 11/15/2022]
Abstract
Objective There is limited literature concerning the outcomes and role of THA as a surgical option for amputee patients. The aim of this study is to determine the mid-to long-term survival and complication rates of cementless total hip arthroplasty (THA) in patients with contralateral below knee amputations. Methods A retrospective review of 54 patients with below knee amputation were perfomed who underwent THA for osteoarthritis of the contralateral hip over a 5-year period between 1999 and 2014. Patients were monitored for at least 5 years and assessed with the Harris Hip Score and activities of daily living scale and by evaluating migration or osteolysis around the acetabular cup and femoral stems (amputee group). The amputee group was compared with a control group (non-amputee group) with the same number of patients. Results Differences in the Harris Hip Score (p = 0.021) and activities of daily living scale (p = 0.043) between the two groups were statistically significant lower in the amputee group at 3 months after surgery. However, no differences were found between the groups from 6 months postoperatively to the last follow-up (Harris Hip Score p = 0.812, activities of daily living scale p = 0.885). Radiologically, any cups or stems showed no signs of migration or osteolysis. In the amputee group, dislocation was found in 1 patient 2 months after arthroplasty (p = 0.315) and long stem revision surgery were performed on two patients due to periprosthetic fracture (p = 0.153). Conclusions THA performed on the contralateral side of patients with below knee amputation is considered to be an effective treatment with good clinical and radiological results at mid-to long-term follow-up. Level of evidence Level IV, therapeutic study.
Collapse
Affiliation(s)
- Hong-Man Cho
- Department of Orthopedic Surgery, Gwangju Veterans Hospital, Gwangju, South Korea.
| | - Jae-Woong Seo
- Department of Orthopedic Surgery, Gwangju Veterans Hospital, Gwangju, South Korea
| | - Hyun-Ju Lee
- Department of Orthopedic Surgery, Gwangju Veterans Hospital, Gwangju, South Korea
| | - Kyu-Bok Kang
- Department of Orthopedic Surgery, Veterans Health Service Medical Center, Seoul, South Korea
| | - Jung-Ryul Kim
- Department of Orthopedic Surgery, Busan Veterans Hospital, Busan, South Korea
| | - Ho-Wook Wee
- Department of Orthopedic Surgery, Daegu Veterans Hospital, Daegu, South Korea
| |
Collapse
|
368
|
Die Pfanneninklinationsmessung in der Beckenübersichtsaufnahme. DER ORTHOPADE 2018; 47:1003-1008. [DOI: 10.1007/s00132-018-3628-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
369
|
Inoue D, Kabata T, Kimura H, Tsuchiya H. A prospective clinical trial to assess the accuracy of an MRI-based patient-specific acetabular instrument guide in total hip arthroplasty. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2018; 29:65-71. [DOI: 10.1007/s00590-018-2279-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2018] [Accepted: 07/23/2018] [Indexed: 12/16/2022]
|
370
|
Shoji T, Yamasaki T, Izumi S, Kenji M, Sawa M, Yasunaga Y, Adachi N. The effect of cup medialization and lateralization on hip range of motion in total hip arthroplasty. Clin Biomech (Bristol, Avon) 2018; 57:121-128. [PMID: 29986274 DOI: 10.1016/j.clinbiomech.2018.06.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Revised: 06/18/2018] [Accepted: 06/22/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND There is little description of the effect of cup position on the hip range of motion in total hip arthroplasty. The purpose is to evaluate the effect of cup medialization/lateralization with a compensatory increase/decrease in femoral offset on the hip range of motion, and whether the bone morphology of the anterior inferior iliac spine affects hip range of motion in total hip arthroplasty. METHODS Using the CT data of 100 patients (male; 30, female; 70), 3D-dynamic motion analysis was performed in four scenarios with cup medialization/lateralization with the same/decreased global offset. We calculated the range of motion before component impingement and bony impingement in flexion, internal rotation and external rotation using the software. Furthermore, we measured bony morphological features of anterior inferior iliac spine, and we analyzed the correlations among them. FINDINGS We found that the cup medialization with the same stem offset had negative effects on hip range of motion in flexion and internal rotation due to bony impingement, whereas cup medialization caused external rotation to significantly decrease with the same global offset. On the other hand, cup lateralization with the same global offset had negative effects on flexion and internal rotation, whereas external rotation increased. Furthermore, there were negative correlations among flexion and laterally large and steep anterior inferior iliac spine. INTERPRETATION Our results demonstrated that the advantage of cup medialization can depend on the individual anatomy such as bony morphology of anterior inferior iliac spine in flexion.
Collapse
Affiliation(s)
- Takeshi Shoji
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
| | - Takuma Yamasaki
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Soutarou Izumi
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Mifuji Kenji
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Mikiya Sawa
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Yuji Yasunaga
- Department of Orthopaedic Surgery, Hiroshima Prefectural Rehabilitation Center, 295-3 Taguchi, Saijo-town, Higashi-hiroshima 739-0036, Japan
| | - Nobuo Adachi
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| |
Collapse
|
371
|
Correct Assessment of Acetabular Component Orientation in Total Hip Arthroplasty From Plane Radiographs. J Arthroplasty 2018; 33:2652-2659.e3. [PMID: 29615377 DOI: 10.1016/j.arth.2018.02.023] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2016] [Revised: 01/25/2018] [Accepted: 02/03/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Correct positioning of the cup is an important factor in total hip arthroplasty. Assessing its position from a plain anteroposterior pelvic radiograph is known to be hampered by systemic errors. This study focuses on developing a correction method to adjust for these potential sources of error and to eliminate them based on a 3D geometric analysis. METHODS Computed tomography scans of 113 (66 male, 47 female) pelvices were reconstructed and virtually projected onto a plain radiograph with varying rotational and translational positions. Thus cup inclination and anteversion as measured on a 2D-radiograph and in the 3D environment were correlated. Projected offset of the symphysis from the mid-sacrum served as a mean to measure pelvic right/left-rotation. Pelvic tilt was determined from the projected height of the contour of the small pelvis. Correction formulas were verified by projecting a gimbal-mounted artificial pelvis with a cup implanted in a known position. RESULTS We found gender-specific formulas that correct for malrotated and off-centered radiographs. Applying these formulas cup inclination was assessed as close as 1.3° (±1.90°) to the true 3D value and cup anteversion as close as 1° (±1.91°) although deviations between directly measured plain values and corrected values rose up to 18°. CONCLUSION Inherent effects of central projection and malrotations due to pelvic tilt, pelvic rotation, and noncentered radiographs are corrected. Evaluation of radiographic inclination and anteversion of acetabular cups from plain 2D-radiographs show improved precision. Real values are approached better than 1.3° when applying our correction formulas.
Collapse
|
372
|
Mohammed W, Abd-Elhaleem M, Eltayeb M. Design and Simulation of Hip Prosthesis using Finite Elements Methods to fulfill Essential Range of Motion. 2018 INTERNATIONAL CONFERENCE ON COMPUTER, CONTROL, ELECTRICAL, AND ELECTRONICS ENGINEERING (ICCCEEE) 2018. [DOI: 10.1109/iccceee.2018.8515764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
373
|
Eachempati KK, Malhotra R, Pichai S, Reddy AVG, Podhili Subramani AK, Gautam D, Bollavaram VR, Sheth NP. Results of trabecular metal augments in Paprosky IIIA and IIIB defects. Bone Joint J 2018; 100-B:903-908. [DOI: 10.1302/0301-620x.100b7.bjj-2017-1604.r1] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims The advent of trabecular metal (TM) augments has revolutionized the management of severe bone defects during acetabular reconstruction. The purpose of this study was to evaluate patients undergoing revision total hip arthroplasty (THA) with the use of TM augments for reconstruction of Paprosky IIIA and IIIB defects. Patients and Methods A retrospective study was conducted at four centres between August 2008 and January 2015. Patients treated with TM augments and TM shell for a Paprosky grade IIIA or IIIB defect, in the absence of pelvic discontinuity, and who underwent revision hip arthroplasty with the use of TM augments were included in the study. A total of 41 patients with minimum follow-up of two years were included and evaluated using intention-to-treat analysis. Results There were 36 (87.8%) patients with a Paprosky IIIA defect and five (12.2%) patients with a Paprosky IIIB defect. The mean age was 56.7 years (28 to 94). There were 21 (51.2%) women and 20 (48.8%) men. The mean follow-up was 39.4 months (12 to 96). One (2%) patient died after eight years. No failures were noted in the series. The mean survivorship was 100% at the time of latest follow-up. Conclusion The results of this multicentre study showed encouraging short- and mid-term results for the use of TM augments in the management of Paprosky grade IIIA and IIIB defects. Cite this article: Bone Joint J 2018;100-B:903–8.
Collapse
Affiliation(s)
- K. K. Eachempati
- Department of Orthopaedics, Max Cure Hospitals, Hyderabad, India
| | - R. Malhotra
- Department of Orthopaedics, All India
Institute of Medical Sciences, New Delhi, India
| | - S. Pichai
- Asian Joint Reconstruction Institute, Chennai, India
| | | | | | - D. Gautam
- Department of Orthopaedics, All India
Institute of Medical Sciences, New Delhi, India
| | - V. R. Bollavaram
- Department of Orthopaedics, Max Cure Hospitals, Hyderabad, India
| | - N. P. Sheth
- Department of Orthopaedic Surgery, University
of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania, USA
| |
Collapse
|
374
|
Sonohata M, Kitajima M, Kawano S, Mawatari M. Comparison of Total Hip Arthroplasty Outcomes after Failed Femoral Wedge or Curved Varus Osteotomy. Open Orthop J 2018; 12:208-217. [PMID: 30008970 PMCID: PMC6018131 DOI: 10.2174/1874325001812010208] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2018] [Revised: 05/27/2018] [Accepted: 06/07/2018] [Indexed: 11/23/2022] Open
Abstract
Background: Differences in clinical and radiographic results following total hip arthroplasty between failed wedge and curved varus osteotomy are unclear. Objective: To investigate differences in clinical and radiographic results following total hip arthroplasty in patients who exhibited failed wedge or curved varus osteotomy. Method: We performed 18 total hip arthroplasties after failed femoral varus osteotomy. Hips were divided into two groups: 14 had failed wedge varus osteotomy and four had failed curved varus osteotomy. Average ages at osteotomy and total hip arthroplasty were 27 years old (range, 10-46 years old) and 56 years old (range, 25-74 years old), respectively. The average duration of follow-up monitoring was 72.2 months (range, 54-91 months). Clinical and radiographic evaluations were completed for each group. Results: The Japanese Orthopaedic Association hip score of total hip arthroplasty after failed varus osteotomy significantly improved at the last follow-up in both groups. However, hip score at the last follow-up was significantly higher after failed curved varus osteotomy than after failed wedge varus osteotomy (p<0.01). Four hips that failed wedge varus osteotomy underwent subtrochanteric corrective osteotomy with total hip arthroplasty. Radiographic evaluation showed that three stems for total hip arthroplasty after failed wedge varus osteotomy were inserted in malposition, and all stems in total hip arthroplasty after failed curved varus osteotomy were inserted in the normal position. Conclusion: Surgeons performing femoral varus osteotomy should consider possible future conversion to total hip arthroplasty. Curved varus osteotomy is more suitable than wedge varus osteotomy for future conversion to total hip arthroplasty.
Collapse
Affiliation(s)
- Motoki Sonohata
- Department of Orthopaedic Surgery, Faculty of Medicine, Saga University 5-1-1 Nabeshima, Saga 849-8501, Japan
| | - Masaru Kitajima
- Department of Orthopaedic Surgery, Faculty of Medicine, Saga University 5-1-1 Nabeshima, Saga 849-8501, Japan
| | - Shunsuke Kawano
- Department of Orthopaedic Surgery, Faculty of Medicine, Saga University 5-1-1 Nabeshima, Saga 849-8501, Japan
| | - Masaaki Mawatari
- Department of Orthopaedic Surgery, Faculty of Medicine, Saga University 5-1-1 Nabeshima, Saga 849-8501, Japan
| |
Collapse
|
375
|
Nogueira JBS, Carvalho ACGDS, Barros Filho EMD, Araújo LHDC, Bezerra MJC, Demange MK. Evaluation of benefits and accuracy of a mobile application in planning total knee arthroplasties. Rev Bras Ortop 2018; 53:142-150. [PMID: 29911079 PMCID: PMC6001150 DOI: 10.1016/j.rboe.2018.02.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Accepted: 02/01/2017] [Indexed: 12/02/2022] Open
Abstract
Objective To evaluate the usefulness of an application when planning total knee arthroplasties (TKA), besides the accuracy when measuring the anatomical-mechanical femoral angle (AMFA), comparing, also, the time spent during planning a TKA manually and by using the application. Methods An interdisciplinary team involving health and computer science areas established activities in order to develop the application. After development, 24 physicians underwent an application usability test. Each one planned a primary total knee arthroplasty (TKA) initially, in a conventional manner and then by using the application. Data concerning AMFA measurement and time spent during planning were collected, in both manners. The Mann–Whitney and Wilcoxon tests were used to evaluate statistical significance related to angle and time. Results Users considered it important checking AMFA and drawing the bone cut lines orthogonal to the mechanical axis, when planning TKAs. They also assessed that the application could be useful for training surgeons and for specialists. There was no statistically significant difference between the AMFA, as measured by the application and by the conventional manner. The planning time was shorter when the application was used (39% of the time spent manually). Conclusions The application has proved to be useful in planning TKAs and has revealed accuracy when measuring the AMFA when it was compared to the manual form of preoperative planning. The application was able to reduce planning time by more than half and it demonstrated reliability in measuring the AMFA.
Collapse
Affiliation(s)
| | | | | | | | | | - Marco Kawamura Demange
- Instituto de Ortopedia e Traumatologia, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, Brazil
| |
Collapse
|
376
|
Tezuka T, Inaba Y, Kobayashi N, Choe H, Higashihira S, Saito T. The influence of patient factors on femoral rotation after total hip arthroplasty. BMC Musculoskelet Disord 2018; 19:189. [PMID: 29885651 PMCID: PMC5994239 DOI: 10.1186/s12891-018-2110-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Accepted: 05/24/2018] [Indexed: 11/25/2022] Open
Abstract
Background A postoperative change in femoral rotation following total hip arthroplasty (THA) might be the cause of dislocation due to the change in combined anteversion. However, very few studies have evaluated the femoral rotation angle following THA, or the factors that influence femoral rotation. We aimed to evaluate changes in femoral rotation after THA, and to investigate preoperative patient factors that influence femoral rotation after THA. Methods This study involved 211 hips treated with primary THA. We used computed tomography to measure the femoral rotation angle before and one week after THA. In addition, multiple regression analysis was performed to evaluate preoperative patient factors that could influence femoral rotation after THA. Results The femoral rotation angle was 0.2 ± 14° externally before surgery and 4.4 ± 12° internally after surgery (p < 0.001). Multiple regression analysis revealed that sex (β = 0.19; p = 0.003), age (β = 0.15; p = 0.017), preoperative anatomical femoral anteversion (β = − 0.25; p = 0.002), and preoperative femoral rotation angle (β = 0.36; p < 0.001) were significantly associated with the postoperative femoral rotation angle. The final model of the regression formula was described by the following equation: [postoperative femoral rotation angle = 5.41 × sex (female: 0, male: 1) + 0.15 × age - 0.22 × preoperative anatomical femoral anteversion + 0.33 × preoperative femoral rotation angle - 10.1]. Conclusion The current study showed the mean internal change of 4.6° in the femoral rotation angle one week after THA. Sex, age, preoperative anatomical femoral anteversion and preoperative femoral rotation were associated with postoperative femoral rotation. The patients who were male, older, and who exhibited lesser preoperative anatomical femoral anteversion or greater preoperative femoral rotation angles, tended to demonstrate an externally rotated femur after THA. Conversely, patients who were female, younger, and who exhibited greater preoperative anatomical femoral anteversion or lesser preoperative femoral rotation angles, tended to demonstrate an internal rotation of the femur after THA.
Collapse
Affiliation(s)
- Taro Tezuka
- Department of Orthopedic Surgery, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, Japan.
| | - Yutaka Inaba
- Department of Orthopedic Surgery, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, Japan
| | - Naomi Kobayashi
- Department of Orthopedic Surgery, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, Japan
| | - Hyonmin Choe
- Department of Orthopedic Surgery, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, Japan
| | - Syota Higashihira
- Department of Orthopedic Surgery, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, Japan
| | - Tomoyuki Saito
- Department of Orthopedic Surgery, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, Japan
| |
Collapse
|
377
|
Alzohiry MA, Abdelnasser MK, Moustafa M, Mahran M, Bakr H, Khalifa Y, Abelaal A, Atta H, Said GZ. Accuracy of plain antero-posterior radiographic-based methods for measurement of acetabular cup version. INTERNATIONAL ORTHOPAEDICS 2018; 42:2777-2785. [PMID: 29869012 DOI: 10.1007/s00264-018-3984-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2017] [Accepted: 05/10/2018] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Acetabular cup version is crucial for successful total hip arthroplasty (THA). Many methods have been described for measurement of cup version angle. The aim of this study is to assess the accuracy of five commonly used methods for measurement of acetabular cup version in plain antero-posterior views of the pelvis and hip. MATERIAL AND METHODS Sixty primary THA cases were subjected postoperatively to plain A-P of the pelvis (AP-P), A-P view of the hip (AP-H), and computed tomography (CT) imaging. The acetabular cup version was measured in AP-P and AP-H by five methods (Lewinnek, Widmer, Hassan et al., Ackland et al., and Liaw et al.). These measurements were compared to the CT measurement. RESULTS All plain X-ray methods showed no significant differences from the CT, except those of Hassan et al. in AP-H, and Widmer and Ackland et al. in AP-P. CONCLUSIONS AND RECOMMENDATIONS For measurement of acetabular cup version angle, we recommend the use of Lewinnek and Liaw et al. methods both in AP-P and in AP-H, while Hassan et al.'s method is recommended in AP-P only, and Widmer and Ackland et al.'s methods in AP-H only.
Collapse
Affiliation(s)
| | | | - Mohamed Moustafa
- Orthopedic Department, Assiut University Hospital, Assiut, Egypt
| | - Mohamed Mahran
- Orthopedic Department, Assiut University Hospital, Assiut, Egypt
| | - Hatem Bakr
- Orthopedic Department, Assiut University Hospital, Assiut, Egypt
| | - Yaser Khalifa
- Orthopedic Department, Assiut University Hospital, Assiut, Egypt
| | - Ahmed Abelaal
- Orthopedic Department, Assiut University Hospital, Assiut, Egypt
| | - Haisam Atta
- Radiology Department, South Egypt Cancer Institute, Assiut University, Assiut, Egypt
| | - Galal Zaki Said
- Orthopedic Department, Assiut University Hospital, Assiut, Egypt
| |
Collapse
|
378
|
Ogawa H, Hasegawa S, Tsukada S, Matsubara M. A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty. J Arthroplasty 2018; 33:1833-1837. [PMID: 29502961 DOI: 10.1016/j.arth.2018.01.067] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2017] [Revised: 01/19/2018] [Accepted: 01/24/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND We developed an acetabular cup placement device, the AR-HIP system, using augmented reality (AR). The AR-HIP system allows the surgeon to view an acetabular cup image superimposed in the surgical field through a smartphone. The smartphone also shows the placement angle of the acetabular cup. This preliminary study was performed to assess the accuracy of the AR-HIP system for acetabular cup placement during total hip arthroplasty (THA). METHODS We prospectively measured the placement angles using both a goniometer and AR-HIP system in 56 hips of 54 patients undergoing primary THA. We randomly determined the order of intraoperative measurement using the 2 devices. At 3 months after THA, the placement angle of the acetabular cup was measured on computed tomography images. The primary outcome was the absolute value of the difference between intraoperative and postoperative computed tomography measurements. RESULTS The measurement angle using AR-HIP was significantly more accurate in terms of radiographic anteversion than that using a goniometer (2.7° vs 6.8°, respectively; mean difference 4.1°; 95% confidence interval, 3.0-5.2; P < .0001). There was no statistically significant difference in terms of radiographic inclination (2.1° vs 2.6°; mean difference 0.5°; 95% confidence interval, -1.1 to 0.1; P = .13). CONCLUSION In this pilot study, the AR-HIP system provided more accurate information regarding acetabular cup placement angle than the conventional method. Further studies are required to confirm the utility of the AR-HIP system as a navigation tool.
Collapse
Affiliation(s)
- Hiroyuki Ogawa
- Department of Orthopaedic Surgery, Nissan Tamagawa Hospital, Tokyo, Japan; Department of Orthopaedic Surgery, The Fraternity Memorial Hospital, Tokyo, Japan
| | - Seiichirou Hasegawa
- Department of Orthopaedic Surgery, The Fraternity Memorial Hospital, Tokyo, Japan
| | - Sachiyuki Tsukada
- Department of Orthopaedic Surgery, Hokusuikai Kinen Hospital, Ibaraki, Japan
| | - Masaaki Matsubara
- Department of Orthopaedic Surgery, Nissan Tamagawa Hospital, Tokyo, Japan
| |
Collapse
|
379
|
Camenzind RS, Stoffel K, Lash NJ, Beck M. Direct anterior approach to the hip joint in the lateral decubitus position for joint replacement. OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE 2018; 30:276-285. [PMID: 29802423 DOI: 10.1007/s00064-018-0550-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Revised: 10/12/2017] [Accepted: 10/23/2017] [Indexed: 11/25/2022]
Abstract
SURGICAL PRINCIPLE AND OBJECTIVE The direct anterior approach for total hip arthroplasty is associated with higher complication rates and difficult femoral component positioning. Performing a modified technique in the lateral position allows secure component positioning. INDICATIONS Primary hip replacement (including femoral neck fracture) and cup revision without bone deficiency. CONTRAINDICATIONS Destruction/deformities of proximal femur or acetabulum, bone deficiency or malignancy. SURGICAL TECHNIQUE Strict lateral decubitus position. Straight anterior incision of 10-12 cm, starting 2 cm lateral to the anterior superior iliac spine. Incision of the fascia over the tensor fascia lata muscle (TFL). Lateral retraction of the TFL. Incision of the fascia and medial retraction of rectus femoris. Ligation of the ascending branch of the lateral femoral circumflex artery. Detachment of the iliocapsularis muscle from the capsule in a medial direction. Anterior capsule excision. Femoral neck osteotomy and removal of the head. Reaming of the acetabulum; insertion the acetabular component. Exposure of the femur. Incision/excision of the capsule medial to the greater trochanter for easy anteriorization of the femur. Reaming and implantation of femoral component. POSTOPERATIVE MANAGEMENT Weight bearing on day one with crutches for 4 weeks; deep vein thrombosis prophylaxis. RESULTS In all, 138 patients (72 women, 66 men, mean age of 67 years) were followed up over 2 years. Overall complication rate was 3.6%: 3 patients (2.2%) with grade III complications required additional intervention. Acetabular cup inclination: 35-50° in 88% of patients. Neutral femoral stem position observed in 99% of patients. Mean Harris hip score improved from 61 preoperatively to 97 after 2 years. Patient satisfaction on a visual analogue scale improved from 3.7 to 9.5.
Collapse
Affiliation(s)
- R S Camenzind
- Clinic of Orthopaedic Surgery, Luzerner Kantonsspital Luzern, Spitalstraße, 6000, Lucerne 16, Switzerland.
| | - K Stoffel
- Clinic of Orthopaedic Surgery, Kantonsspital Baselland, Liestal, Switzerland
- University of Basel, Basel, Switzerland
| | - N J Lash
- Clinic of Orthopaedic Surgery, Luzerner Kantonsspital Luzern, Spitalstraße, 6000, Lucerne 16, Switzerland
- Consultant Surgeon, Christchurch Public Hospital, Christchurch, New Zealand
| | - M Beck
- Clinic of Orthopaedic Surgery, Luzerner Kantonsspital Luzern, Spitalstraße, 6000, Lucerne 16, Switzerland
| |
Collapse
|
380
|
Park CH, Ha YC, Lee YK, Koo KH. Using Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty Necessitating 44- or 46-mm Metal Shells. Orthopedics 2018; 41:e354-e359. [PMID: 29570759 DOI: 10.3928/01477447-20180320-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2017] [Accepted: 12/15/2017] [Indexed: 02/03/2023]
Abstract
Ceramic-on-ceramic articulation shows the lowest wear, with a low incidence of osteolysis. A small cup limits options regarding liner thickness and femoral implant size. The purpose of this study was to evaluate the safety of a 4-mm-thick ceramic liner and the outcomes of cementless total hip arthroplasty using a 44- or 46-mm metal shell and a ceramic-on-ceramic bearing at mid- to long-term follow-up. Between May 2003 and June 2008, 80 patients (88 hips) who had hip osteoarthritis and a hypoplastic acetabulum underwent cementless total hip arthroplasty using a 44- or 46-mm metal shell and a ceramic-on-ceramic bearing. Sixty-eight of these patients (76 hips) were followed for an average of 8 years. The ceramic-related complications, clinical and radiological results, and Kaplan-Meier survivorship of these patients were evaluated. Mean Harris hip score had improved to 88 points (range, 49-100 points) at final follow-up. No ceramic fractures occurred during follow-up. All acetabular and femoral prostheses had bone ingrowth, and there was no measurable wear in any hip. In 1 patient, a radiolucent lesion occurred around the acetabular cup. Two hips underwent revision because of periprosthetic fractures. The survival rates of the acetabular cups and the femoral stems were 100% and 97.4%, respectively. The thin (4 mm) ceramic liner did not increase the risk of ceramic fracture and did not affect the mid- to long-term results and survival of cementless total hip arthroplasty using 44- or 46-mm metal shells. [Orthopedics. 2018; 41(3):e354-e359.].
Collapse
|
381
|
Formby PM, Nappo KE, Purcell RL, Pickett A, Newman MT, Mack AW. The effect of BMI and surgical approach on acetabular component malpositioning in a cohort of military patients with hip arthroplasty. CURRENT ORTHOPAEDIC PRACTICE 2018. [DOI: 10.1097/bco.0000000000000615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
382
|
Lee YK, Kim JW, Kim TY, Ha YC, Koo KH. Validity of the intra-operative measurement of stem anteversion and factors for the erroneous estimation in cementless total hip arthroplasty using postero-lateral approach. Orthop Traumatol Surg Res 2018; 104:341-346. [PMID: 29458202 DOI: 10.1016/j.otsr.2017.11.023] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Revised: 11/07/2017] [Accepted: 11/23/2017] [Indexed: 02/02/2023]
Abstract
BACKGROUND Intra-operative estimation of stem anteversion in total hip arthroplasty (THA) using postero-lateral approach is made by the surgeon's visual assessment, using the tibia as a guide, with the assumption that tibial axis is vertical to the trans-epicondylar axis. However, the accuracy of the intra-operative estimation has rarely been verified with postoperative CT-scans, with controversies regarding these measurements particularly in case of knee osteoarthritis. Therefore we performed a prospective study to: (1) determine the accuracy of the intra-operative measurement and (2) investigate factors affecting the discrepancy between the surgeon's estimation and the real stem anteversion. HYPOTHESIS Intra-operative estimation of stem anteversion correlated with the real stem anteversion on CT-scan. PATIENTS AND METHODS Sixty-seven THAs using cementless straight stems (65 patients) without ipsilateral total knee arthroplasty were prospectively evaluated to compare the intra-operative measurement of stem anteversion with the real stem anteversion on computed tomography (CT) scans. There were 33 men and 34 women with a mean age of 59.7years (range, 27-84years) at the time of surgery. Age, tibia plateau angle, native femoral anteversion, femoro-tibial angle, body mass index, operative site, gender, coronal and sagittal tilt of the stem, stem type, ipsilateral knee osteoarthritis, and preoperative diagnosis were analyzed to evaluate the factors affecting the discrepancy between the intra-operative and CT measurements. RESULTS The intra-operative estimation (mean, 21.5°±8.5°; range, 5.0°-39.0°) was greater than the CT measurement (mean, 19.5°±8.7°; range, 4.5°-38.5°) by 2.0°. The mean absolute value of discrepancy was 4.5°. The correlation coefficient between intra-operative and CT measurements was 0.837. The femoro-tibial angle was associated with the discrepancy between the two measurements. In the presence of genu varum deformity, the intra-operative measurement underestimated the stem anteversion. DISCUSSION Although intra-operative estimation of stem anteversion was slightly greater than the real stem anteversion, there was an excellent correlation between the two. The femoro-tibial angle should be considered to optimize the stem anteversion during cementless THA using postero-lateral approach. LEVEL OF EVIDENCE Level III, prospective case control study.
Collapse
Affiliation(s)
- Y K Lee
- Seoul National University Bundang Hospital, Department of Orthopaedic Surgery, 166 Gumi-ro, Bundang-gu, Seongnam 463-707 South Korea
| | - J W Kim
- Seoul National University Bundang Hospital, Department of Orthopaedic Surgery, 166 Gumi-ro, Bundang-gu, Seongnam 463-707 South Korea
| | - T Y Kim
- Hallym University Sacred Heart Hospital, Department of Orthopaedic Surgery, 896 Pyeongchon-dong, Dongan-gu, Anyang 431-070, South Korea; Konkuk University Medical Center, Department of Orthopaedic Surgery, School of Medicine, Konkuk University, Seoul 05030, South Korea.
| | - Y C Ha
- Chung-Ang University, College of Medicine, Department of Orthopaedic Surgery, 224-1 Heukseok-dong, Dongjak-gu, Seoul 156-755, South Korea
| | - K H Koo
- Seoul National University Bundang Hospital, Department of Orthopaedic Surgery, 166 Gumi-ro, Bundang-gu, Seongnam 463-707 South Korea
| |
Collapse
|
383
|
Effect of Pelvic Tilt and Rotation on Cup Orientation in Both Supine and Standing Positions. J Arthroplasty 2018; 33:1442-1448. [PMID: 29276116 DOI: 10.1016/j.arth.2017.11.069] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Revised: 11/15/2017] [Accepted: 11/30/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study is to analyze the effect of pelvic tilt and rotation on radiographic measurement of cup orientation. METHODS A total of 68 patients (79 hips) were included in this study. The patients had a computed tomography study and approximately 3 months of postoperative standing anteroposterior pelvic radiographs in both supine and standing positions. We used 2-dimensional (2D)/3-dimensional (3D) matching to measure pelvic tilt and rotation, and cup orientation. RESULTS There was a wide range of pelvic tilt between individuals in both supine and standing positions. Supine pelvic tilt was different from standing pelvic tilt (P < .05). There were differences in cup anteversion before and after 2D/3D matching in both supine and standing positions (P < .05). Supine and standing pelvic tilt correlated with differences in cup anteversion before and after 2D/3D matching. When all 79 hips were separated into right and left side, pelvic rotation inversely correlated with the pelvic tilt-adjusted difference in anteversion before and after 2D/3D matching of the right side but directly correlated with that of the left side in both supine and standing positions. CONCLUSION This study demonstrated that the measurement of cup anteversion on anteroposterior radiographs is significantly affected by both pelvic tilt and pelvic rotation (depending on the side). Improved understanding of pelvic orientation and improved ability to measure pelvic orientation may eventually allow for desired cup positioning to potentially protect against complications associated with malposition of the cup.
Collapse
|
384
|
Clinical Results of Total Hip Arthroplasty in Two Patients with Charcot Hip Joints due to Congenital Insensivity to Pain with Anhydrosis. Case Rep Orthop 2018; 2018:1743068. [PMID: 29666733 PMCID: PMC5831877 DOI: 10.1155/2018/1743068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2017] [Accepted: 12/26/2017] [Indexed: 11/20/2022] Open
Abstract
Traditionally, Charcot arthropathy has been considered an absolute contraindication for total hip arthroplasty (THA). However, some recent reports have shown that good short- to mid-term results can be achieved by improving the durability of the implant. This paper reports the mid- to long-term results of THA in two patients with Charcot hip joints caused by congenital insensivity to pain with anhydrosis. Both patients suffered multiple posterior dislocations in the six months immediately following surgery. However, with the continuous use of a hard abduction brace, one patient was eventually able to walk with a lofstrand cane and the other with the use of one crutch. Although one patient experienced a dislocation five years after surgery, X-rays taken after nine years and five years, respectively, revealed no clinical signs of implant loosening. We conclude that, with careful planning and appropriate precautions, THA may be a viable treatment option for Charcot hip joints caused by congenital insensivity to pain with anhydrosis.
Collapse
|
385
|
Park YS, Shin WC, Lee SM, Kwak SH, Bae JY, Suh KT. The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs. J Orthop Surg Res 2018; 13:66. [PMID: 29609639 PMCID: PMC5879940 DOI: 10.1186/s13018-018-0767-4] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Accepted: 03/16/2018] [Indexed: 12/02/2022] Open
Abstract
Background Several radiological methods for measuring the anteversion of the acetabular component after total hip arthroplasty (THA) exist, and no single standardized method has been established. We evaluated the reliability and accuracy of six widely utilized methods (Liaw et al., Lewinnek et al., Widmer, Hassan et al., Ackland et al., and Woo and Morrey) for measuring anteversion on plain radiographs, using a reference standard in the same definition obtained from the PolyWare programme. Methods We reviewed 71 patients who underwent primary unilateral THA. The anteversion of the acetabular component was measured on pelvis AP radiographs using five different methods (Liaw et al., Lewinnek et al., Widmer, Hassan et al., and Ackland et al.) and on cross-table lateral radiographs using the method of Woo and Morrey. The values obtained using the PolyWare programme, which determines the anteversion of the acetabular component by edge detection, were regarded as the reference standard. Results Intra- and inter-observer reliabilities were excellent for all methods using plain radiographs, including the PolyWare programme. The method of Liaw et al. obtained values similar to those obtained using the PolyWare programme and was thus considered accurate (P = 0.447). However, values obtained using the other five methods significantly differed from those obtained using the PolyWare programme and were thus considered less accurate (P < 0.001, P < 0.001, P < 0.001, P = 0.007, and P < 0.001, respectively). Conclusion The method of Liaw et al. is more accurate than other methods using plain radiographs for the measurement of the anteversion of the acetabular component after THA, with reference to the anteversion obtained from the PolyWare programme.
Collapse
Affiliation(s)
- Yang Soo Park
- Department of Orthopedics, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, South Korea
| | - Won Chul Shin
- Department of Orthopedics, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, South Korea
| | - Sang Min Lee
- Department of Orthopedics, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, South Korea
| | - Sang Ho Kwak
- Department of Orthopedics, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, South Korea
| | - Jung Yun Bae
- Department of Orthopedics, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, South Korea
| | - Kuen Tak Suh
- Department of Orthopedics, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, South Korea. .,Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, 20 Geumo-ro, Mulgeum-eup, Yangsan, Gyeongsangnam-do, 626-770, South Korea.
| |
Collapse
|
386
|
Nakahara I, Kyo T, Kuroda Y, Miki H. Effect of improved navigation performance on the accuracy of implant placement in total hip arthroplasty with a CT-based navigation system. J Artif Organs 2018; 21:340-347. [PMID: 29611147 DOI: 10.1007/s10047-018-1041-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2017] [Accepted: 03/27/2018] [Indexed: 12/28/2022]
Abstract
A computed tomography (CT)-based navigation system is one of the support tools to place implant with appropriate alignment and position in total hip arthroplasty (THA). To determine whether the higher performance of the navigation would further improve the accuracy of implant placement in the clinical setting, we retrospectively compared the navigation accuracy of two different versions of a navigation system. The newer version of the navigation system had an upgraded optical sensor with superior positional accuracy. Navigation accuracy, defined as differences between postoperative measurements on CT images and intraoperative records on the navigation system, of 49 THAs performed with the newer version of the navigation system was compared with that of 49 THAs performed with the older version. With the newer version, the mean absolute accuracy (95% limits of agreement) of implant alignment was 1.2° (± 3.3°) for cup inclination, 1.0° (± 2.4°) for cup anteversion, 2.0° (± 4.9°) for stem anteversion, and 1.1° (± 2.4°) for stem valgus angle. The accuracy of the implant position was 1.5 mm (± 3.1 mm), 1.3 mm (± 3.0 mm), and 1.5 mm (± 3.1 mm) for cup x-, y-, and z-axes, respectively, 1.6 mm (± 3.2 mm), 1.4 mm (± 2.9 mm), and 1.5 mm (± 2.7 mm) for stem x-, y-, and z-axes, respectively, and 2.4 mm (± 4.5 mm) for leg length discrepancy. The values for the newer version were significantly more accurate with less variation compared to those of the older version. With upgraded navigation performance, more accurate implant placement was demonstrated in the clinical setting.
Collapse
Affiliation(s)
- Ichiro Nakahara
- Department of Orthopaedic Surgery, Osaka National Hospital, 2-1-14 oenzaka, Chuo-ku, Osaka, 5400006, Japan.
| | - Takayuki Kyo
- Department of Orthopaedic Surgery, Bellland General Hospital, 500-3 Higashiyama, Naka-ku, Sakai-city, Osaka, Japan
| | - Yasuo Kuroda
- Department of Orthopaedic Surgery, Osaka National Hospital, 2-1-14 oenzaka, Chuo-ku, Osaka, 5400006, Japan
| | - Hidenobu Miki
- Department of Orthopaedic Surgery, Osaka National Hospital, 2-1-14 oenzaka, Chuo-ku, Osaka, 5400006, Japan
| |
Collapse
|
387
|
Hip malformation is a very common finding in young patients scheduled for total hip arthroplasty. Arch Orthop Trauma Surg 2018; 138:581-589. [PMID: 29429067 DOI: 10.1007/s00402-018-2900-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2017] [Indexed: 10/18/2022]
Abstract
INTRODUCTION In Denmark, 20% of all registered total hip arthroplasties (THA) from 1995 to 2014 has been patients younger than 60 years with primary idiopathic osteoarthritis (OA). It is speculated that hip malformations may be a major contributor to early OA development. It has been shown that hip malformation may compromise implant position and, therefore, identifying and knowing the incidence of malformations is important. Our aim was to assess the prevalence and type of hip malformations in a cohort of younger patients undergoing THA. MATERIALS AND METHODS In this prospective two center cohort study, 95 consecutive patients (106 hips) met the inclusion criteria. One observer performed radiographic measurements for malformations and radiographic OA. Inter- and intraobserver variability was assessed. RESULTS From 95 patients (male n = 52 and female n = 43) age ranged from 35 to 59 years and prevalences of hip malformations were; CAM-deformity 50.9 and 25.5%, coxa profunda 33 and 27.4%, acetabular retroversion 33 and 29.2%, and acetabular dysplasia 10.4 and 3.8%. All patients showed minimum of one malformation. Prevalences of Tönnis grade 0-1 were 22.6% and 2-3 were 77.4%. CONCLUSION All patients showed malformations, especially high prevalences were found for CAM-deformity, coxa profunda and acetabular retroversion. Identifying these malformations is fairly simple and recognizing the high prevalence may help surgeons avoid pitfalls during implant positioning in THA surgery. Further, focus on hip malformations may facilitate correct referral to joint-preserving surgery before OA develops.
Collapse
|
388
|
Nakamura N, Maeda Y, Hamawaki M, Sakai T, Sugano N. Effect of soft-tissue impingement on range of motion during posterior approach Total Hip Arthroplasty: an in vivo measurement study. Comput Assist Surg (Abingdon) 2018; 21:132-136. [PMID: 27973946 DOI: 10.1080/24699322.2016.1223347] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Abstract
PURPOSE While implant impingement and bony impingement have been recognized as causes of poor outcomes in total hip arthroplasty (THA), reports of soft-tissue impingement are rare. To clarify the issue, the effect of anterior capsule resection on hip range of motion (ROM) was quantitatively measured in vivo during posterior approach THA using a CT-based hip navigation system. MATERIALS AND METHODS For 47 patients (51 hips), hip ROM was measured intraoperatively before and after resection of the anterior hip capsule, and the difference was compared. RESULTS Resection of the anterior hip capsule brought about an average 6° increase of ROM in the direction of flexion with internal rotation and did not markedly change ROM in other directions. CONCLUSIONS During THA through a posterior approach, soft-tissue impingement by the anterior hip capsule can occur. Clinically, we expect that resection of the anterior hip capsule can reduce the risk of posterior instability without increasing the risk of anterior instability.
Collapse
Affiliation(s)
- Nobuo Nakamura
- a Center of Arthroplasty, Kyowakai Hospital , Suita-city , Osaka , Japan
| | - Yuki Maeda
- a Center of Arthroplasty, Kyowakai Hospital , Suita-city , Osaka , Japan
| | - Makoto Hamawaki
- a Center of Arthroplasty, Kyowakai Hospital , Suita-city , Osaka , Japan
| | - Takashi Sakai
- b Department of Orthopedic Surgery , Osaka University Medical School , Suita-city , Osaka , Japan
| | - Nobuhiko Sugano
- b Department of Orthopedic Surgery , Osaka University Medical School , Suita-city , Osaka , Japan
| |
Collapse
|
389
|
Soft tissue tension is four times lower in the unstable primary total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2018; 42:2059-2065. [DOI: 10.1007/s00264-018-3908-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Accepted: 03/16/2018] [Indexed: 01/25/2023]
|
390
|
Kim WY, Ko MS, Lee SW, Kim KS. Short-term Outcomes of Ceramic Coated Metal-on-Metal Large Head in Total Hip Replacement Arthroplasty. Hip Pelvis 2018; 30:12-17. [PMID: 29564292 PMCID: PMC5861020 DOI: 10.5371/hp.2018.30.1.12] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Revised: 12/11/2017] [Accepted: 12/21/2017] [Indexed: 11/29/2022] Open
Abstract
Purpose This study characterizes the short-term outcomes of ceramic coated metal-on-metal (MoM) large head total hip arthroplasty (THA) in prospectively selected patients aged 70 to 75 years. Materials and Methods Eighteen patients (18 hips) between the ages of 70 and 75-years old with THA using ceramic-coated MoM large heads between June 2014 and December 2014 were evaluated. We prospectively selected patients younger than 70 years for bipolar hemiarthroplasty and older than 75 years for conventional THA. There were one case of osteoarthritis, 8 cases of femur neck fracture, and 9 cases of intertrochanteric fracture. All patients underwent clinical and radiological follow-up at 6 weeks, 6 and 12 months, and every year postoperatively. The mean duration of follow-up was 24.2 months (range, 18–34 months). Results The average Harris hip score at the final follow-up was 81.0, except one case which was ultimately converted to conventional THA due to acetabular cup loosening. Radiographically, mean acetabular cup inclination was 45.8°(range, 38–56°) and anteversion was 20.1° (range, 11–25°). The average femoral head size was 48.7 mm. All stems were neutral-positioned except 1 varus-positioned stem. There was 1 case of a soft tissue infection, 3 patients complained of persistent groin pain, and no dislocations occurred. Conclusion Ceramic coated large MOM articulation (ACCIS) have many complications: cup loosening, groin pain, which can lead to fatal outcomes in the elderly patients. Especially in patients with communicated intertrochanter fracture (AO 31-A22, 23), careful attention should be paid to the choice of surgical option.
Collapse
Affiliation(s)
- Weon-Yoo Kim
- Department of Orthopedic Surgery, The Catholic University of Korea, Daejeon St. Mary's Hospital, Daejeon, Korea
| | - Myung-Sup Ko
- Department of Orthopedic Surgery, The Catholic University of Korea, Daejeon St. Mary's Hospital, Daejeon, Korea
| | - Se-Won Lee
- Department of Orthopedic Surgery, The Catholic University of Korea, Daejeon St. Mary's Hospital, Daejeon, Korea
| | - Kwang-Sub Kim
- Department of Orthopedic Surgery, The Catholic University of Korea, Daejeon St. Mary's Hospital, Daejeon, Korea
| |
Collapse
|
391
|
Yuasa T, Maezawa K, Sato H, Maruyama Y, Kaneko K. Safely transitioning to the direct anterior from posterior approach for total hip arthroplasty. J Orthop 2018; 15:420-423. [PMID: 29881168 DOI: 10.1016/j.jor.2018.03.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Accepted: 03/16/2018] [Indexed: 12/27/2022] Open
Abstract
Purpose We compare the complication rate in transition to direct anterior (DAA) from posterior approach (PA) for total hip arthroplasty (THA). Methods This is a retrospective cohort single-surgeon study of consecutive primary THAs over a transition period from PA to DAA. Results There were no significant differences in dislocation rate, femoral fracture, lateral femoral cutaneous nerve injury or success rate in cup inclination and anteversion angle between two groups. Conclusion We conclude that this single-surgeon study demonstrates the safely transitioning to DAA from PA in THA with no significant increase in complications in a selected patients.
Collapse
Affiliation(s)
- Takahito Yuasa
- Department of Orthopaedic Surgery, Juntendo University Urayasu Hospital, Japan
| | - Katsuhiko Maezawa
- Department of Orthopaedic Surgery, Juntendo University Urayasu Hospital, Japan
| | - Hironobu Sato
- Department of Orthopaedic Surgery, Juntendo University Urayasu Hospital, Japan
| | - Yuichiro Maruyama
- Department of Orthopaedic Surgery, Juntendo University Urayasu Hospital, Japan
| | - Kazuo Kaneko
- Department of Orthopaedic Surgery, Juntendo University, Japan
| |
Collapse
|
392
|
Total hip arthroplasty via an anterolateral supine approach for obese patients increases the risk of greater trochanteric fracture. J Orthop 2018; 15:379-383. [PMID: 29881158 DOI: 10.1016/j.jor.2018.03.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 03/16/2018] [Indexed: 11/21/2022] Open
Abstract
Purpose The aim of this study was to evaluate the outcomes and early complications of obese patients who underwent total hip arthroplasty for osteoarthritis via an anterolateral approach in the supine position (ALS-THA) and compare these outcome with of a matched control group of non-obese patients. Patients and methods Thirty-one hips in 28 patients with obesity (BMI ≧ 30 kg/m2) were included in this study. As a control group, 31 hips of 31 patients with a normal weight (BMI between 20 and 25 kg/m2) were matched based on age, sex, and laterality. Clinical evaluations using the Merle d'Aubigne and Postel hip score, radiological evaluations and perioperative complications were compared in two groups. Results There were no significant differences between the groups in the operative time, period of hospitalization, clinical hip score, or cup positioning, although the position of the cup tended to deviate from the optimal safe zone in the obese compared with non-obese group (32.3 and 16.1%, respectively). There was no infection, dislocation, nerve palsy, or life-threatening event in either group. The rate of avulsion fractures of the greater trochanter in the obese group was 3 times higher compared to that in the non-obese group. Conclusions As the clinical outcome of ALS-THA for the obese group is not inferior to that for the non-obese group, obesity is not considered to be a contraindication for ALS-THA. However, obesity increases the risk of intraoperative greater trochanteric fracture. Thus, surgeons should be particularly careful when manipulating the femur in this class of patients, who should be informed of this risk.
Collapse
|
393
|
Shimodaira H, Tensho K, Akaoka Y, Koyama S, Maruyama M, Kato H, Saito N. The Acetabular Fossa May Not Be Located at the True Center of the Acetabulum: A Detailed Analysis Using Preoperative CT Images. J Bone Joint Surg Am 2018; 100:e27. [PMID: 29509621 DOI: 10.2106/jbjs.17.00362] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The acetabular fossa is thought to be located in the center of the acetabulum, and acetabular reaming in total hip arthroplasty is conventionally performed in the center of the fossa. However, the actual location of the fossa and the influence that hypoplasia or deformity may have on the position of the fossa are unknown. We hypothesized that the fossa is located in the center of the acetabulum, regardless of hypoplasia or deformity. METHODS Fifty patients with normal hips (normal hip group), 50 patients with dysplasia who underwent rotational acetabular osteotomy (dysplastic hip group), and 46 patients with osteoarthritis who underwent total hip arthroplasty (osteoarthritic hip group) were evaluated by computed tomography (CT) imaging. On the horizontal plane that passes through the center of the femoral head, the center line of the acetabulum was defined as the perpendicular bisector of the anterior and posterior rims of the acetabulum. The angle and distance of the center of the acetabular fossa in relation to the center line of the acetabulum were evaluated; furthermore, the center position of the fossa from the anterior margin of the acetabulum was calculated as a ratio relative to acetabular size. A 1-way analysis of variance was performed to compare measurements among the 3 groups. RESULTS The center of the acetabular fossa was positioned anteriorly to the center line of the acetabulum in all 3 groups. The mean center angle of the acetabular fossa was 14.0° ± 3.8°, 15.2° ± 5.6°, and 14.9° ± 5.5° in the normal, dysplastic, and osteoarthritic hip groups, respectively (p = 0.33). The mean center distance of the acetabular fossa was 5.6 ± 1.8, 5.8 ± 2.3, and 6.1 ± 2.2 mm, respectively (p = 0.55). The mean center position of the acetabular fossa was 38.8% ± 3.3%, 38.5% ± 4.2%, and 38.3% ± 3.9%, respectively (p = 0.71). CONCLUSIONS The center of the acetabular fossa is positioned anteriorly to the center of the acetabulum, and the positioning is affected by neither dysplasia nor osteoarthritis. The preconception that the center of the acetabulum corresponds to the center of the acetabular fossa may risk eccentric reaming, possibly damaging the anterior wall. LEVEL OF EVIDENCE Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Hiroki Shimodaira
- Department of Orthopedic Surgery (H.S., K.T., Y.A., S.K., and H.K.) and Institute for Biomedical Sciences, Interdisciplinary Cluster for Cutting Edge Research (N.S.), Shinshu University School of Medicine, Matsumoto, Japan
| | - Keiji Tensho
- Department of Orthopedic Surgery (H.S., K.T., Y.A., S.K., and H.K.) and Institute for Biomedical Sciences, Interdisciplinary Cluster for Cutting Edge Research (N.S.), Shinshu University School of Medicine, Matsumoto, Japan
| | - Yusuke Akaoka
- Department of Orthopedic Surgery (H.S., K.T., Y.A., S.K., and H.K.) and Institute for Biomedical Sciences, Interdisciplinary Cluster for Cutting Edge Research (N.S.), Shinshu University School of Medicine, Matsumoto, Japan
| | - Suguru Koyama
- Department of Orthopedic Surgery (H.S., K.T., Y.A., S.K., and H.K.) and Institute for Biomedical Sciences, Interdisciplinary Cluster for Cutting Edge Research (N.S.), Shinshu University School of Medicine, Matsumoto, Japan
| | - Masaaki Maruyama
- Department of Orthopedic Surgery, Shinonoi General Hospital, Nagano, Japan
| | - Hiroyuki Kato
- Department of Orthopedic Surgery (H.S., K.T., Y.A., S.K., and H.K.) and Institute for Biomedical Sciences, Interdisciplinary Cluster for Cutting Edge Research (N.S.), Shinshu University School of Medicine, Matsumoto, Japan
| | - Naoto Saito
- Department of Orthopedic Surgery (H.S., K.T., Y.A., S.K., and H.K.) and Institute for Biomedical Sciences, Interdisciplinary Cluster for Cutting Edge Research (N.S.), Shinshu University School of Medicine, Matsumoto, Japan
| |
Collapse
|
394
|
Myers CA, Laz PJ, Shelburne KB, Judd DL, Huff DN, Winters JD, Stevens-Lapsley JE, Rullkoetter PJ. The impact of hip implant alignment on muscle and joint loading during dynamic activities. Clin Biomech (Bristol, Avon) 2018; 53:93-100. [PMID: 29482087 PMCID: PMC5890933 DOI: 10.1016/j.clinbiomech.2018.02.010] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Revised: 01/09/2018] [Accepted: 02/12/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Component alignment is an important consideration in total hip arthroplasty. The impact of changes in alignment on muscle forces and joint contact forces during dynamic tasks are not well understood, and have the potential to influence surgical decision making. The objectives of this study were to assess the impact of femoral head/stem and cup component placement on hip muscle and joint contact forces during tasks of daily living and to identify which alignment parameters have the greatest impact on joint loading. METHODS Using a series of strength-calibrated, subject-specific musculoskeletal models of patients performing gait, sit-to-stand and step down tasks, component alignments were perturbed and joint contact and muscle forces evaluated. FINDINGS Based on the range of alignments reported clinically, variation in head/stem anteversion-retroversion had the largest impact of any degree of freedom throughout all three tasks; average contact forces 413.5 (319.1) N during gait, 262.7 (256.4) N during sit to stand, and 572.7 (228.1) N during the step down task. The sensitivity of contact force to anteversion-retroversion of the head/stem was 31.5 N/° for gait, which was similar in magnitude to anterior-posterior position of the cup (34.6 N/m for gait). Additionally, superior-inferior cup alignment resulted in 16.4 (4.9)° of variation in the direction of the hip joint contact force across the three tasks, with the most inferior cup placements moving the force vector towards the cup equator at the point of peak joint contact force. INTERPRETATION A quantitative understanding of the impact and potential tradeoffs when altering component alignment is valuable in supporting surgical decision making.
Collapse
Affiliation(s)
- Casey A Myers
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO, USA.
| | - Peter J Laz
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO, USA
| | - Kevin B Shelburne
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO, USA
| | - Dana L Judd
- Physical Therapy Program, University of Colorado, Aurora, CO, USA
| | | | - Joshua D Winters
- Physical Therapy Program, University of Colorado, Aurora, CO, USA
| | - Jennifer E Stevens-Lapsley
- Physical Therapy Program, University of Colorado, Aurora, CO, USA; Geriatric Research Education and Clinical Center, VA Eastern Colorado Healthcare System, Denver, CO, USA
| | - Paul J Rullkoetter
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO, USA
| |
Collapse
|
395
|
Bargar WL, Parise CA, Hankins A, Marlen NA, Campanelli V, Netravali NA. Fourteen Year Follow-Up of Randomized Clinical Trials of Active Robotic-Assisted Total Hip Arthroplasty. J Arthroplasty 2018; 33:810-814. [PMID: 29107496 DOI: 10.1016/j.arth.2017.09.066] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2017] [Revised: 09/11/2017] [Accepted: 09/25/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Active robotic total hip arthroplasty (THA) has been used clinically for over 20 years, but long-term results have never been studied. The aims of this study are to determine whether active robotic THA improves clinical outcomes and results in fewer revisions over a long-term follow-up. METHODS Patients from 2 US Food and Drug Administration clinical trials (1994-1998 and 2001-2006) who had undergone THA using either an active robotic system or a traditional manual technique were examined to determine if any differences existed in radiographic analysis and patient pain and function using the University of California, Los Angeles; visual analog scale; Health Status Questionnaire (HSQ) pain; HSQ role physical; HSQ physical functioning; Harris pain scores; and the total Western Ontario and McMaster Universities Osteoarthritis Index scores at a mean follow-up of 14 years. RESULTS The ROBODOC group had statistically significant higher HSQ pain and Harris pain scores and lower Western Ontario and McMaster Universities Osteoarthritis Index scores. There was no statistically significant difference in probability of a revision for wear between the groups (χ2 = 1.80; P = .179), and no revisions for loosening in either group. CONCLUSION Prior studies have demonstrated improved implant fit and alignment with the use of this active robot system. This long-term study now shows no failures for stem loosening at a mean follow-up of 14 years and small but potentially important improvements in clinical outcomes in the robot group.
Collapse
Affiliation(s)
- William L Bargar
- Department of Orthopaedics, Sutter Medical Center Sacramento, University of California at Davis School of Medicine, Sacramento, California
| | - Carol A Parise
- Sutter Health, Sutter Institute for Medical Research, Sacramento, California
| | - Andrea Hankins
- Sutter Health, Sutter Institute for Medical Research, Sacramento, California
| | - Natalie A Marlen
- Sutter Health, Sutter Institute for Medical Research, Sacramento, California
| | | | | |
Collapse
|
396
|
Nogueira JBS, Carvalho ACGDS, Barros Filho EMD, Araújo LHDC, Bezerra MJC, Demange MK. Avaliação de utilidade e acurácia de aplicativo móvel no planejamento de artroplastias totais do joelho. Rev Bras Ortop 2018. [DOI: 10.1016/j.rbo.2017.02.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
397
|
Uemura K, Atkins PR, Fiorentino NM, Anderson AE. Hip rotation during standing and dynamic activities and the compensatory effect of femoral anteversion: An in-vivo analysis of asymptomatic young adults using three-dimensional computed tomography models and dual fluoroscopy. Gait Posture 2018; 61:276-281. [PMID: 29413797 PMCID: PMC6599491 DOI: 10.1016/j.gaitpost.2018.01.016] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Revised: 01/18/2018] [Accepted: 01/20/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Individuals are thought to compensate for femoral anteversion by altering hip rotation. However, the relationship between hip rotation in a neutral position (i.e. static rotation) and dynamic hip rotation is poorly understood, as is the relationship between anteversion and hip rotation. RESEARCH OBJECTIVE Herein, anteversion and in-vivo hip rotation during standing, walking, and pivoting were measured in eleven asymptomatic, morphologically normal, young adults using three-dimensional computed tomography models and dual fluoroscopy. METHODS Using correlation analyses, we: 1) determined the relationship between hip rotation in the static position to that measured during dynamic activities, and 2) evaluated the association between femoral anteversion and hip rotation during dynamic activities. Hip rotation was calculated while standing (static-rotation), throughout gait, as a mean during gait (mean gait rotation), and as a mean (mid-pivot rotation), maximum (max-rotation) and minimum (min-rotation) during pivoting. RESULTS Static-rotation (mean ± standard deviation; 11.3° ± 7.3°) and mean gait rotation (7.8° ± 4.7°) were positively correlated (r = 0.679, p = 0.022). Likewise, static-rotation was strongly correlated with mid-pivot rotation (r = 0.837, p = 0.001), max-rotation (r = 0.754, p = 0.007), and min-rotation (r = 0.835, p = 0.001). Strong positive correlations were found between anteversion and hip internal rotation during all of the stance phase (0-60% gait) and during mid- and terminal-swing (86-100% gait) (all r > 0.607, p < 0.05). CONCLUSIONS Our results suggest that the static position may be used cautiously to express the neutral rotational position of the femur for dynamic movements. Further, our results indicate that femoral anteversion is compensated for by altering hip rotation. As such, both anteversion and hip rotation may be important to consider when diagnosing hip pathology and planning for surgical procedures.
Collapse
Affiliation(s)
- Keisuke Uemura
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA.
| | - Penny R Atkins
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA; Department of Bioengineering, University of Utah, James LeVoy Sorenson Molecular Biotechnology Building, 36 S. Wasatch Drive, Rm. 3100, Salt Lake City, UT 84112 USA.
| | - Niccolo M Fiorentino
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA; Mechanical Engineering Department, University of Vermont, 33 Colchester Ave, Votey Hall 201A, Burlington, VT 05405, USA.
| | - Andrew E Anderson
- Department of Orthopaedics, University of Utah, 590 Wakara Way, Salt Lake City, UT, 84108, USA; Department of Bioengineering, University of Utah, James LeVoy Sorenson Molecular Biotechnology Building, 36 S. Wasatch Drive, Rm. 3100, Salt Lake City, UT 84112 USA; Department of Physical Therapy, University of Utah, 520 Wakara Way, Suite 240, Salt Lake City, UT 84108, USA; Scientific Computing and Imaging Institute, 72 S Central Campus Drive, Room 3750, Salt Lake City, UT 84112, USA.
| |
Collapse
|
398
|
Zhao JX, Su XY, Zhao Z, Xiao RX, Zhang LC, Tang PF. Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup. INTERNATIONAL ORTHOPAEDICS 2018; 42:1819-1825. [PMID: 29453586 DOI: 10.1007/s00264-018-3809-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Accepted: 01/23/2018] [Indexed: 10/18/2022]
Abstract
AIM The aim of this study is to demonstrate the varying rules of radiographic angles following varying three-dimensional (3D) orientations and locations of cup using an accurate mathematical model. METHODS A cone model is established to address the quantitative relationship between the opening circle of cup and its ellipse projection on radiograph. The varying rules of two-dimensional (2D) radiographic anteversion (RA) and inclination (RI) angles can be analyzed. RESULTS When the centre of cup is located above X-ray source, with proper 3D RI/RA angles, 2D RA angle can be equal to its 3D counterpart, and 2D RI angle is usually greater than its 3D counterpart. Except for the original point on hip-centered anterior-posterior radiograph, there is no area on radiograph where both 2D RA and RI angles are equal to their 3D counterparts simultaneously. DISCUSSION This study proposes an innovative model for accurately explaining how 2D RA/RI angles of cup are varying following different 3D RA/RI angles and location of cup. The analysis results provide clinicians an intuitive grasp of knowledge about 2D RA/RI angles greater or smaller than their 3D counterparts post-operatively. The established model may allow determining the effects of pelvic rotations on 2D radiographic angles of cup.
Collapse
Affiliation(s)
- Jing-Xin Zhao
- Department of Orthopaedics, Chinese PLA General Hospital, Beijing, 100853, China
| | - Xiu-Yun Su
- Department of Orthopaedics, Chinese PLA General Hospital, Beijing, 100853, China
| | - Zhe Zhao
- Department of Orthopaedics, Beijing Tsinghua Chang Gung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, 102218, China
| | - Ruo-Xiu Xiao
- School of Computer and Communication Engineering, University of Science and Technology Beijing, Beijing, 100083, China
| | - Li-Cheng Zhang
- Department of Orthopaedics, Chinese PLA General Hospital, Beijing, 100853, China.
| | - Pei-Fu Tang
- Department of Orthopaedics, Chinese PLA General Hospital, Beijing, 100853, China.
| |
Collapse
|
399
|
Penenberg BL, Samagh SP, Rajaee SS, Woehnl A, Brien WW. Digital Radiography in Total Hip Arthroplasty: Technique and Radiographic Results. J Bone Joint Surg Am 2018; 100:226-235. [PMID: 29406344 DOI: 10.2106/jbjs.16.01501] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Obtaining the ideal acetabular cup position in total hip arthroplasty remains a challenge. Advancements in digital radiography and image analysis software allow the assessment of the cup position during the surgical procedure. This study describes a validated technique for evaluating cup position during total hip arthroplasty using digital radiography. METHODS Three hundred and sixty-nine consecutive patients undergoing total hip arthroplasty were prospectively enrolled. Preoperative supine anteroposterior pelvic radiographs were made. Intraoperative anteroposterior pelvic radiographs were made with the patient in the lateral decubitus position. Radiographic beam angle adjustments and operative table adjustments were made to approximate rotation and tilt of the preoperative radiograph. The target for cup position was 30° to 50° abduction and 15° to 35° anteversion. Intraoperative radiographic measurements were calculated and final cup position was determined after strict impingement and range-of-motion testing. Postoperative anteroposterior pelvic radiographs were made. Two independent observers remeasured all abduction and anteversion angles. RESULTS Of the cups, 97.8% were placed within 30° to 50° of abduction, with a mean angle (and standard deviation) of 39.5° ± 4.6°. The 2.2% of cups placed outside the target zone were placed so purposefully on the basis of intraoperative range-of-motion testing and patient factors, and 97.6% of cups were placed between 15° and 35° of anteversion, with a mean angle of 26.6° ± 4.7°. Twenty-eight percent of cups were repositioned on the basis of intraoperative measurements. Subluxation during range-of-motion testing occurred in 3% of hips despite acceptable measurements, necessitating cup repositioning. There was 1 early anterior dislocation. CONCLUSIONS Placing the acetabular component within a target range is a critical component to minimizing dislocation and polyethylene wear in total hip arthroplasty. Using digital radiography, we positioned the acetabular component in our desired target zone in 97.8% of cases and outside the target zone, purposefully, in 2.2% of cases. When used in conjunction with strict impingement testing, digital radiography allows for predictable cup placement in total hip arthroplasty.
Collapse
Affiliation(s)
- Brad L Penenberg
- Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, California
| | - Sanjum P Samagh
- Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, California
| | - Sean S Rajaee
- Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, California
| | - Antonia Woehnl
- Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, California
| | | |
Collapse
|
400
|
Uemura K, Takao M, Otake Y, Koyama K, Yokota F, Hamada H, Sakai T, Sato Y, Sugano N. Can Anatomic Measurements of Stem Anteversion Angle Be Considered as the Functional Anteversion Angle? J Arthroplasty 2018; 33:595-600. [PMID: 28993085 DOI: 10.1016/j.arth.2017.09.027] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Revised: 08/02/2017] [Accepted: 09/12/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Stem anteversion angle is important in the combined anteversion theory to avoid implant impingement after total hip arthroplasty (THA). However, anatomic measurements of stem anteversion angle may not represent functional anteversion of the femur if the femur undergoes axial rotation. Herein, the femoral rotational angle (FRA) was measured in supine and standing positions before and after THA to evaluate the difference between anatomic and functional measurements. METHODS A total of 191 hips (174 patients) treated with THA for osteoarthritis were analyzed in this retrospective, case-controlled study. The FRA was measured as the angle between the posterior condylar line and the line through the bilateral anterior superior iliac spines (positive for external rotation) and was measured preoperatively and postoperatively in supine and standing positions with computed tomography segmentation and landmark localization of the pelvis and the femur followed by intensity-based 2D-3D registration. The number of cases in which the absolute FRA remained <15° in both positions was also calculated. RESULTS The average ± standard deviation preoperative FRA was 0.3° ± 8.3° in the supine position and -4.5° ± 8.8° during standing; the postoperative FRA was -3.8° ± 9.0° in supine and -14.3° ± 8.3° during standing. There were 134 cases (70%) in which the preoperative absolute FRA remained <15° in both positions while only 85 hips (45%) remained <15°, postoperatively. CONCLUSION Substantial variability was seen in the FRA, especially during the postoperative period. These results suggest that the anatomic stem anteversion angle may not represent the functional anteversion of the femur.
Collapse
Affiliation(s)
- Keisuke Uemura
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Masaki Takao
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Yoshito Otake
- Graduate School of Information Science, Nara Institute of Science and Technology, Ikoma, Nara, Japan
| | - Koki Koyama
- Graduate School of Information Science, Nara Institute of Science and Technology, Ikoma, Nara, Japan
| | - Futoshi Yokota
- Graduate School of Information Science, Nara Institute of Science and Technology, Ikoma, Nara, Japan
| | - Hidetoshi Hamada
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Takashi Sakai
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| | - Yoshinobu Sato
- Graduate School of Information Science, Nara Institute of Science and Technology, Ikoma, Nara, Japan
| | - Nobuhiko Sugano
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
| |
Collapse
|