401
|
Role of brachytherapy in the boost management of anal carcinoma with node involvement (CORS-03 study). Int J Radiat Oncol Biol Phys 2012. [PMID: 23195780 DOI: 10.1016/j.ijrobp.2012.09.034] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
PURPOSE To assess retrospectively the clinical outcome in anal cancer patients, with lymph node involvement, treated with split-course radiation therapy and receiving a boost through external beam radiation therapy (EBRT) or brachytherapy (BCT). METHODS AND MATERIALS From 2000 to 2005, among 229 patients with invasive nonmetastatic anal squamous cell carcinoma, a selected group of 99 patients, with lymph node involvement, was studied. Tumor staging reported was T1 in 4 patients, T2 in 16 patients, T3 in 49 patients, T4 in 16 patients, and T unknown in 14 patients and as N1 in 67 patients and N2/N3 in 32 patients. Patients underwent a first course of EBRT (mean dose, 45.1 Gy) followed by a boost (mean dose, 18 Gy) using EBRT (50 patients) or BCT (49 patients). All characteristics of patients and tumors were well balanced between the BCT and EBRT groups. Prognostic factors of cumulative rate of local recurrence (CRLR), cumulative rate of distant (including nodal) recurrence (CRDR), colostomy-free survival (CFS) rate, and overall survival (OS) rate were analyzed for the overall population and according to the nodal status classification. RESULTS The median follow-up was 71.5 months. The 5-year CRLR, CRDR, CFS rate, and OS rate were 21%, 19%, 63%, and 74.4%, respectively. In the overall population, the type of node involvement (N1 vs N2/N3) was the unique independent prognostic factor for CRLR. In N1 patients, by use of multivariate analysis, BCT boost was the unique prognostic factor for CRLR (4% for BCT vs 31% for EBRT; hazard ratio, 0.08; P=.042). No studied factors were significantly associated with CRDR, CFS, and OS. No difference with regard to boost technique and any other factor studied was observed in N2/N3 patients for any kind of recurrence. CONCLUSION In anal cancer, even in the case of initial perirectal node invasion, BCT boost is superior to EBRT boost for CRLR, without an influence on OS, suggesting that N1 status should not be a contraindication to use of a BCT boost technique, as well as emphasizing the important of investigating the benefit of BCT boost in prospective randomized trials.
Collapse
|
402
|
Appenzoller LM, Michalski JM, Thorstad WL, Mutic S, Moore KL. Predicting dose-volume histograms for organs-at-risk in IMRT planning. Med Phys 2012; 39:7446-61. [DOI: 10.1118/1.4761864] [Citation(s) in RCA: 270] [Impact Index Per Article: 20.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
403
|
Lee VHF, Ng SCY, Choi CW, Luk MY, Leung TW, Au GKH, Kwong DLW. Comparative analysis of dosimetric parameters of three different radiation techniques for patients with Graves' ophthalmopathy treated with retro-orbital irradiation. Radiat Oncol 2012. [PMID: 23181900 PMCID: PMC3573990 DOI: 10.1186/1748-717x-7-199] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Background We would like to investigate the if IMRT produced better target coverage and dose sparing to adjacent normal structures as compared with 3-dimensional conformal radiotherapy (3DCRT) and lateral opposing fields (LOF) for patients with Graves’ ophthalmopathy treated with retro-orbital irradiation. Methods Ten consecutive patients diagnosed with Graves’ ophthalmopathy were prospectively recruited into this study. An individual IMRT, 3DCRT and LOF plan was created for each patient. Conformity index (CI), homogeneity index (HI) and other dosimetric parameters of the targets and organs-at-risk (OAR) generated by IMRT were compared with the other two techniques. Results Mann–Whitney U test demonstrated that CI generated by IMRT was superior to that produced by 3DCRT and LOF (p=0.005 for both respectively). Similarly HI with IMRT was proven better than 3DCRT (p=0.007) and LOF (p=0.005). IMRT gave rise to better dose sparing to some OARs including globes, lenses and optic nerves as compared with 3DCRT but not with LOF. Conclusions IMRT, as compared with 3DCRT and LOF, was found to have a better target coverage, conformity and homogeneity and dose sparing to some surrounding structures, despite a slight increase but clinically negligible dose to other structures. Dosimetrically it might be a preferred treatment technique and a longer follow up is warranted to establish its role in routine clinical use.
Collapse
Affiliation(s)
- Victor H F Lee
- Department of Clinical Oncology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, 1/F, Professorial Block, Queen Mary Hospital, 102 Pokfulam Road, Pokfulam, Hong Kong.
| | | | | | | | | | | | | |
Collapse
|
404
|
Sobotta B, Söhn M, Alber M. Accelerated evaluation of the robustness of treatment plans against geometric uncertainties by Gaussian processes. Phys Med Biol 2012; 57:8023-39. [DOI: 10.1088/0031-9155/57/23/8023] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
405
|
Böhlen TT, Brons S, Dosanjh M, Ferrari A, Fossati P, Haberer T, Patera V, Mairani A. Investigating the robustness of ion beam therapy treatment plans to uncertainties in biological treatment parameters. Phys Med Biol 2012; 57:7983-8004. [DOI: 10.1088/0031-9155/57/23/7983] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
406
|
(Radio)biological optimization of external-beam radiotherapy. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2012; 2012:329214. [PMID: 23251227 PMCID: PMC3508750 DOI: 10.1155/2012/329214] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2012] [Accepted: 08/31/2012] [Indexed: 12/25/2022]
Abstract
“Biological optimization” (BIOP) means planning treatments using (radio)biological criteria and models, that is, tumour control probability and normal-tissue complication probability. Four different levels of BIOP are identified: Level I is “isotoxic” individualization of prescription dose Dpresc at fixed fraction number. Dpresc is varied to keep the NTCP of the organ at risk constant. Significant improvements in local control are expected for non-small-cell lung tumours. Level II involves the determination of an individualized isotoxic combination of Dpresc and fractionation scheme. This approach is appropriate for “parallel” OARs (lung, parotids). Examples are given using our BioSuite software. Hypofractionated SABR for early-stage NSCLC is effectively Level-II BIOP. Level-III BIOP uses radiobiological functions as part of the inverse planning of IMRT, for example, maximizing TCP whilst not exceeding a given NTCP. This results in non-uniform target doses. The NTCP model parameters (reflecting tissue “architecture”) drive the optimizer to emphasize different regions of the DVH, for example, penalising high doses for quasi-serial OARs such as rectum. Level-IV BIOP adds functional imaging information, for example, hypoxia or clonogen location, to Level III; examples are given of our prostate “dose painting” protocol, BioProp. The limitations of and uncertainties inherent in the radiobiological models are emphasized.
Collapse
|
407
|
Lee TF, Ting HM, Chao PJ, Wang HY, Shieh CS, Horng MF, Wu JM, Yeh SA, Cho MY, Huang EY, Huang YJ, Chen HC, Fang FM. Dosimetric advantages of generalised equivalent uniform dose-based optimisation on dose-volume objectives in intensity-modulated radiotherapy planning for bilateral breast cancer. Br J Radiol 2012; 85:1499-506. [PMID: 23091290 PMCID: PMC3500793 DOI: 10.1259/bjr/24112047] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2011] [Revised: 03/08/2012] [Accepted: 03/19/2012] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE We compared and evaluated the differences between two models for treating bilateral breast cancer (BBC): (i) dose-volume-based intensity-modulated radiation treatment (DV plan), and (ii) dose-volume-based intensity-modulated radiotherapy with generalised equivalent uniform dose-based optimisation (DV-gEUD plan). METHODS The quality and performance of the DV plan and DV-gEUD plan using the Pinnacle(3) system (Philips, Fitchburg, WI) were evaluated and compared in 10 patients with stage T2-T4 BBC. The plans were delivered on a Varian 21EX linear accelerator (Varian Medical Systems, Milpitas, CA) equipped with a Millennium 120 leaf multileaf collimator (Varian Medical Systems). The parameters analysed included the conformity index, homogeneity index, tumour control probability of the planning target volume (PTV), the volumes V(20 Gy) and V(30 Gy) of the organs at risk (OAR, including the heart and lungs), mean dose and the normal tissue complication probability. RESULTS Both plans met the requirements for the coverage of PTV with similar conformity and homogeneity indices. However, the DV-gEUD plan had the advantage of dose sparing for OAR: the mean doses of the heart and lungs, lung V(20) (Gy), and heart V(30) (Gy) in the DV-gEUD plan were lower than those in the DV plan (p<0.05). CONCLUSIONS A better result can be obtained by starting with a DV-generated plan and then improving it by adding gEUD-based improvements to reduce the number of iterations and to improve the optimum dose distribution. Advances to knowledge The DV-gEUD plan provided superior dosimetric results for treating BBC in terms of PTV coverage and OAR sparing than the DV plan, without sacrificing the homogeneity of dose distribution in the PTV.
Collapse
Affiliation(s)
- T-F Lee
- Medical Physics & Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung, Taiwan.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
408
|
Tanyi JA, Doss EJ, Kato CM, Monaco DL, ZMeng L, Chen Y, Kubicky CD, Marquez CM, Fuss M. Dynamic conformal arc cranial stereotactic radiosurgery: implications of multileaf collimator margin on dose-volume metrics. Br J Radiol 2012; 85:e1058-66. [PMID: 23091293 PMCID: PMC3500804 DOI: 10.1259/bjr/79414773] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2011] [Revised: 02/26/2012] [Accepted: 02/28/2012] [Indexed: 12/25/2022] Open
Abstract
OBJECTIVE The effect of multileaf collimator (MLC) margin on target and normal tissue dose-volume metrics for intracranial stereotactic radiosurgery (SRS) was assessed. METHODS 118 intracranial lesions of 83 SRS patients formed the basis of this study. For each planning target volume (PTV), five separate treatment plans were generated with MLC margins of -1, 0, 1, 2 and 3 mm, respectively. Identical treatment planning parameters were employed with a median of five dynamic conformal arcs using the Varian/BrainLab high-definition MLC for beam shaping. Prescription dose (PD) was such that 22 Gy covered at least 95% of the PTV. Dose-volume and dose-response comparative metrics included conformity index, heterogeneity index, dose gradient, tumour control probability (TCP) and normal tissue complication probability (NTCP). RESULTS Target dose heterogeneity decreased with increasing MLC margin (p<0.001); mean heterogeneity index decreased from 70.4 ± 12.7 to 10.4 ± 2.2%. TCP decreased with increasing MLC margin (p<0.001); mean TCP decreased from 81.0 ± 2.3 to 62.2 ± 1.8%. Normal tissue dose fall-off increased with MLC margin (p<0.001); mean gradient increased from 3.1 ± 0.9 mm to 5.3 ± 0.7 mm. NTCP was optimal at 1 mm MLC margin. No unambiguous correlation was observed between NTCP and PTV volume. Plan delivery efficiency generally improved with larger margins (p<0.001); mean monitor unit per centigray of the PD decreased from 3.60 ± 1.30 to 1.56 ± 0.13. Conclusion Use of 1 mm MLC margins for dynamic conformal arc-based cranial radiosurgery resulted in optimal tumour control and normal tissue sparing. Clinical significance of these comparative findings warrants further investigation.
Collapse
Affiliation(s)
- J A Tanyi
- Department of Radiation Medicine, Oregon Health and Science University, Portland, OR 97239, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
409
|
Mapping of RBE-Weighted Doses Between HIMAC– and LEM–Based Treatment Planning Systems for Carbon Ion Therapy. Int J Radiat Oncol Biol Phys 2012; 84:854-60. [DOI: 10.1016/j.ijrobp.2012.01.038] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2011] [Revised: 01/10/2012] [Accepted: 01/12/2012] [Indexed: 11/23/2022]
|
410
|
Grün R, Friedrich T, Elsässer T, Krämer M, Zink K, Karger CP, Durante M, Engenhart-Cabillic R, Scholz M. Impact of enhancements in the local effect model (LEM) on the predicted RBE-weighted target dose distribution in carbon ion therapy. Phys Med Biol 2012; 57:7261-74. [PMID: 23075883 DOI: 10.1088/0031-9155/57/22/7261] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Biological optimization for treatment planning in carbon ion therapy is currently based on the first version of the local effect model (LEM I). Further developments implemented in the latest version (LEM IV) allowed to predict more accurately the Relative Biological Effectiveness (RBE) in-vitro. The main goal of this study is to compare the LEM IV against LEM I under treatment-like conditions for idealized target geometries. Therefore, physical dose distributions resulting from the biological optimization with LEM I were used to recalculate the RBE-weighted dose distribution based on LEM IV. Input parameters representing the clinical endpoints late toxicity in the central nervous system and the tumor control for chordoma were chosen to investigate the impact of changes on the predicted isoeffective dose levels. The recalculated RBE-weighted dose distributions show an increase within the target region, and the mean RBE-weighted dose values are dependent on the geometry and decrease with increasing target dimension. The differences between predictions of LEM IV and LEM I are less than 10% for typical tumor volumes treated in the pilot project at GSI. Median RBE-weighted doses predicted by LEM IV in the target region are consistent with clinically observed dose-response behavior as demonstrated by comparison to the 5-year local control curve for skull base chordoma.
Collapse
Affiliation(s)
- R Grün
- Department of Biophysics, GSI Helmholtz Centre for Heavy Ion Research, Darmstadt, Germany.
| | | | | | | | | | | | | | | | | |
Collapse
|
411
|
Evaluation of Dosimetric Consequences of Seroma Contour Variability in Accelerated Partial Breast Irradiation Using a Constructed Representative Seroma Contour. Int J Radiat Oncol Biol Phys 2012; 84:527-32. [DOI: 10.1016/j.ijrobp.2011.11.060] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2011] [Revised: 11/16/2011] [Accepted: 11/26/2011] [Indexed: 11/23/2022]
|
412
|
Tudor GSJ, Rimmer YL, Nguyen TB, Cowen MA, Thomas SJ. Consideration of the likely benefit from implementation of prostate image-guided radiotherapy using current margin sizes: a radiobiological analysis. Br J Radiol 2012; 85:1263-71. [PMID: 22337688 PMCID: PMC3487058 DOI: 10.1259/bjr/27924223] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2010] [Revised: 08/10/2011] [Accepted: 10/17/2011] [Indexed: 12/25/2022] Open
Abstract
OBJECTIVE To estimate the benefit of introduction of image-guided radiotherapy (IGRT) to prostate radiotherapy practice with current clinical target volume-planning target volume (PTV) margins of 5-10 mm. METHODS Systematic error data collected from 50 patients were used together with a random error of σ=3.0 mm to model non-IGRT treatment. IGRT was modelled with residual errors of Σ=σ=1.5 mm. Population tumour control probability (TCP(pop)) was calculated for two three-dimensional conformal radiotherapy techniques: two-phase and concomitant boost. Treatment volumes and dose prescriptions were ostensibly the same. The relative field sizes of the treatment techniques, distribution of systematic errors and correlations between movement axes were examined. RESULTS The differences in TCP(pop) between the IGRT and non-IGRT regimes were 0.3% for the two-phase and 1.5% for the concomitant boost techniques. A 2-phase plan, in each phase of which the 95% isodose conformed to its respective PTV, required fields that were 3.5 mm larger than those required for the concomitant boost plan. Despite the larger field sizes, the TCP (without IGRT) in the two-phase plan was only 1.7% higher than the TCP in the concomitant boost plan. The deviation of craniocaudal systematic errors (p=0.02) from a normal distribution, and the correlation of translations in the craniocaudal and anteroposterior directions (p<0.0001) were statistically significant. CONCLUSIONS The expected population benefit of IGRT for the modelled situation was too small to be detected by a clinical trial of reasonable size, although there was a significant benefit to individual patients. For IGRT to have an observable population benefit, the trial would need to use smaller margins than those used in this study. Concomitant treatment techniques permit smaller fields and tighter conformality than two phases planned separately.
Collapse
Affiliation(s)
- G S J Tudor
- University of Cambridge Department of Oncology, Oncology Centre, Addenbrookes Hospital, Cambridge, UK.
| | | | | | | | | |
Collapse
|
413
|
Comp Plan: A computer program to generate dose and radiobiological metrics from dose-volume histogram files. Med Dosim 2012; 37:305-9. [DOI: 10.1016/j.meddos.2011.11.004] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2010] [Revised: 09/24/2011] [Accepted: 11/29/2011] [Indexed: 12/25/2022]
|
414
|
Pehlivan B, Ares C, Lomax AJ, Stadelmann O, Goitein G, Timmermann B, Schneider RA, Hug EB. Temporal Lobe Toxicity Analysis After Proton Radiation Therapy for Skull Base Tumors. Int J Radiat Oncol Biol Phys 2012; 83:1432-40. [DOI: 10.1016/j.ijrobp.2011.10.042] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2010] [Revised: 10/20/2011] [Accepted: 10/24/2011] [Indexed: 10/28/2022]
|
415
|
Sgouros G, Hobbs RF. Patient-Specific Dosimetry, Radiobiology, and the Previously-Treated Patient. ACTA ACUST UNITED AC 2012. [DOI: 10.1007/174_2012_684] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
|
416
|
A retrospective study of SBRT of metastases in patients with primary sarcoma. Med Oncol 2012; 29:3431-9. [PMID: 22815154 PMCID: PMC3505552 DOI: 10.1007/s12032-012-0256-2] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2012] [Accepted: 05/11/2012] [Indexed: 12/18/2022]
Abstract
We retrospectively reviewed the results of stereotactic body radiotherapy (SBRT) in 46 patients with a total of 136 metastases from primary sarcoma. The purpose of this study was to evaluate the overall response rate and side effects of SBRT in metastatic sarcoma. The patients were treated at Karolinska University Hospital between 1994 and 2005, using 3D conformal multifield technique and a stereotactic body-frame. Prescribed doses ranged from 4 to 20 Gy per fraction in 1–5 fractions, with total doses of 10–48 Gy. All 46 patients were diagnosed with a primary sarcoma. The treated metastases were localized mainly in the lungs. A total number of 136 metastases were treated (1–14 per patient). Overall response rate (local control = CR, PR and SD) for each tumour was 88 % (119/135). Median follow-up was 21.8 months (range 2.7–112.8 months). Thirteen patients (31 %) were long-term survivors (>36 months), and 5 patients are still alive after last follow-up. Two cases of serious non-lethal side effects were seen, one patient had a colon perforation and another patient had contracture of the hip region. SBRT is a safe, convenient and effective non-invasive treatment with high local control for patients with metastatic sarcoma.
Collapse
|
417
|
Panet-Raymond V, Ansbacher W, Zavgorodni S, Bendorffe B, Nichol A, Truong PT, Beckham W, Vlachaki M. Coplanar versus noncoplanar intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment planning for fronto-temporal high-grade glioma. J Appl Clin Med Phys 2012; 13:3826. [PMID: 22766954 PMCID: PMC5716518 DOI: 10.1120/jacmp.v13i4.3826] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2011] [Revised: 03/19/2012] [Accepted: 03/23/2012] [Indexed: 12/02/2022] Open
Abstract
The purpose of this study was to compare dosimetric and radiobiological parameters of treatment plans using coplanar and noncoplanar beam arrangements in patients with fronto‐temporal high‐grade glioma (HGG) generated for intensity‐modulated radiotherapy (IMRT) or volumetric‐modulated arc therapy (VMAT). Ten cases of HGG overlapping the optic apparatus were selected. Four separate plans were created for each case: coplanar IMRT, noncoplanar IMRT (ncIMRT), VMAT, and noncoplanar VMAT (ncVMAT). The prescription dose was 60 Gy in 30 fractions. Dose‐volume histograms and equivalent uniform doses (EUD) for planning target volumes (PTVs) and organs at risk (OARs) were generated. The four techniques resulted in comparable mean, minimum, maximum PTV doses, and PTV EUDs (p≥0.33). The mean PTV dose and EUD averaged for all techniques were 59.98 Gy (Standard Deviation (SD)±0.15) and 59.86 Gy (SD±0.27). Noncoplanar IMRT significantly reduced contralateral anterior globe EUDs (6.7 Gy versus 8.2 Gy, p=0.05), while both ncIMRT and ncVMAT reduced contralateral retina EUDs (16 Gy versus 18.8 Gy, p=0.03). Noncoplanar techniques resulted in lower contralateral temporal lobe dose (22.2 Gy versus 24.7 Gy). Compared to IMRT, VMAT techniques required fewer monitor units (755 vs. 478, p≤0.001) but longer optimization times. Treatment delivery times were 6.1 and 10.5 minutes for coplanar and ncIMRT versus 2.9 and 5.0 minutes for coplanar and ncVMAT. In this study, all techniques achieved comparable target coverage. Superior sparing of contralateral optic structures was seen with ncIMRT. The VMAT techniques reduced treatment delivery duration but prolonged plan optimization times, compared to IMRT techniques. Technique selection should be individualized, based on patient‐specific clinical and dosimetric parameters. PACS number: 87
Collapse
Affiliation(s)
- Valerie Panet-Raymond
- Department of Radiation Oncology, McGill University Health Centre, Montreal, QC, Canada.
| | | | | | | | | | | | | | | |
Collapse
|
418
|
Arvold ND, Niemierko A, Broussard GP, Adams J, Fullerton B, Loeffler JS, Shih HA. Projected Second Tumor Risk and Dose to Neurocognitive Structures After Proton Versus Photon Radiotherapy for Benign Meningioma. Int J Radiat Oncol Biol Phys 2012; 83:e495-500. [DOI: 10.1016/j.ijrobp.2011.10.056] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2011] [Revised: 10/24/2011] [Accepted: 10/25/2011] [Indexed: 10/14/2022]
|
419
|
Potentials of robust intensity modulated scanning proton plans for locally advanced lung cancer in comparison to intensity modulated photon plans. Radiother Oncol 2012; 104:45-51. [DOI: 10.1016/j.radonc.2012.03.017] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2012] [Revised: 03/21/2012] [Accepted: 03/26/2012] [Indexed: 12/25/2022]
|
420
|
Risk-adaptive volumetric modulated arc therapy using biological objective functions for subvolume boosting in radiotherapy. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2012; 2012:348471. [PMID: 22792127 PMCID: PMC3390113 DOI: 10.1155/2012/348471] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2012] [Accepted: 04/26/2012] [Indexed: 11/24/2022]
Abstract
Objectives. Simultaneous integrated boost (SIB) for prostate cancer allows increases in tumor control probability while respecting normal tissue dose constraints. Biological optimization functions that optimize based on treatment outcome can be used to create SIB prostate plans. This study investigates the feasibility of biologically optimized volumetric modulated arc therapy (VMAT) for SIB prostate radiotherapy. Methods. Five prostate cancer patients with diffusion-weighted MR images were selected for analysis. A two-step VMAT optimization was performed, which consisted of an initial biological optimization of a static gantry angle delivery followed by conversion of the static delivery to a single arc VMAT plan. A dosimetric analysis was performed on the resulting plans. Results. The VMAT plans resulted in a ΔEUD between the prostate and the boost volume of between 15.1 Gy and 20.3 Gy. Rectal volumes receiving 75.6 Gy ranged from 4.5 to 9.9%. Expected rectal normal tissue complication probabilities were between 8.6% and 21.4%. Maximum bladder doses ranged from 73.6 Gy to 75.8 Gy. Estimated treatment time was 120 s or less. Conclusions. The presented biological optimization method resulted in deliverable VMAT plans that achieved sufficient modulation for SIB without violating rectal and bladder dose constraints. Advances in knowledge. This study presents a method for creating simultaneous integrated boost VMAT treatments using biological outcome objective functions.
Collapse
|
421
|
Qi XS, Yang Q, Lee SP, Li XA, Wang D. An Estimation of Radiobiological Parameters for Head-and-Neck Cancer Cells and the Clinical Implications. Cancers (Basel) 2012; 4:566-80. [PMID: 24213325 PMCID: PMC3712697 DOI: 10.3390/cancers4020566] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2012] [Revised: 05/29/2012] [Accepted: 06/06/2012] [Indexed: 11/28/2022] Open
Abstract
In vitro survival measurements using two human head-and-neck cancer (HNC) cell lines were performed. The specially designed split-dose surviving fraction was obtained and fitted to the linear-quadratic formalism. The repair halftime (Tr), the potential doubling time (Td), a/β and radiosensitivity a, were estimated. Other radiobiological models: EUD, BED, TCP, etc., were used to examine the potential treatment effectiveness of different IMRT techniques. Our data indicated the repair halftime of ~17 min based on two HNC cell lines. The combined a/β, a and Td are a/β = 8.1 ± 4.1 Gy, a = 0.22 ± 0.08 Gy-1, Td = 4.0 ± 1.8 day, respectively. The prolonged IMRT dose delivery for entire HNC treatment course could possibly result in the loss of biological effectiveness, i.e., the target EUDs decreased by 11% with fraction dose delivery time varying from 5 to 30 min. We determined the sublethal damage repair halftime and other radiobiological parameters for HNC cells, and to evaluate treatment effectiveness of the prolonged dose delivery times associated with different IMRT techniques. The estimated repair halftime for HNC is relatively short and may be comparable to the step-and-shoot IMRT fraction dose delivery time. The effectiveness of IMRT treatment may be improved by reducing the fraction delivery time for HNC treatment.
Collapse
Affiliation(s)
- X Sharon Qi
- Department of Radiation Oncology, University of California Los Angeles, 200 ULCA Medical Plaza, Los Angeles, CA 90024, USA.
| | | | | | | | | |
Collapse
|
422
|
Lin H, Jing J, Xu L, Wu D, Xu Y. Combining the LKB NTCP model with radiosensitivity parameters to characterize toxicity of radionuclides based on a multiclonogen kidney model: a theoretical assessment. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2012; 35:165-76. [PMID: 22678954 DOI: 10.1007/s13246-012-0141-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2011] [Accepted: 05/10/2012] [Indexed: 12/25/2022]
Abstract
The Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) model is often used to estimate the damage level to normal tissue. However, it does not manifestly involve the influence of radiosensitivity parameters. This work replaces the generalized mean equivalent uniform dose (gEUD) with the equivalent uniform dose (EUD) in the LKB model to investigate the effect of a variety of radiobiological parameters on the NTCP to characterize the toxicity of five types of radionuclides. The dose for 50 % complication probability (D (50)) is replaced by the corresponding EUD for 50 % complication probability (EUD(50)). The properties of a variety of radiobiological characteristics, such as biologically effective dose (BED), NTCP, and EUD, for five types of radioisotope ((131)I, (186)Re, (188)Re, (90)Y, and (67)Cu) are investigated by various radiosensitivity parameters such as intrinsic radiosensitivity α, alpha-beta ratio α/β, cell repair half-time, cell mean clonogen doubling time, etc. The high-energy beta emitters ((90)Y and (188)Re) have high initial dose rate and mean absorbed dose per injected activity in kidney, and their kidney toxicity should be of greater concern if they are excreted through kidneys. The radiobiological effect of (188)Re changes most sharply with the radiobiological parameters due to its high-energy electrons and very short physical half-life. The dose for a probability of 50% injury within 5y (D (50/5)) 28 Gy for whole-kidney irradiation should be adjusted according to different radionuclides and different radiosensitivity of individuals. The D (50/5) of individuals with low α/β or low α, or low biological clearance half-time, will be less than 28 Gy. The 50 % complication probability dose for (67)Cu and (188)Re could be 25 Gy and 22 Gy. The same mean absorbed dose generally corresponds to different degrees of damage for tissues of different radiosensitivity and different radionuclides. The influence of various radiobiological parameters should be taken into consideration in the NTCP model.
Collapse
Affiliation(s)
- Hui Lin
- School of Electronic Science & Application Physics, Hefei University of Technology, Hefei, China.
| | | | | | | | | |
Collapse
|
423
|
Davidson MTM, Masucci GL, Follwell M, Blake SJ, Xu W, Moseley DJ, Sanghera P, Wong CS, Perry J, Tsao M, Sahgal A. Single Arc Volumetric Modulated Arc Therapy for Complex Brain Gliomas: Is There an Advantage as Compared to Intensity Modulated Radiotherapy or by Adding a Partial Arc? Technol Cancer Res Treat 2012; 11:211-20. [DOI: 10.7785/tcrt.2012.500289] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
The objective of this study was to determine if volumetric modulated arc therapy (VMAT) offers advantages over intensity modulated radiotherapy (IMRT) for complex brain gliomas and evaluate the role of an additional partial arc. Twelve patients with glioma involving critical organs at risk (OAR) were selected [six low grade brainstem glioma (BG) and six glioblastoma (GB) cases]. BGs were prescribed 54 Gy/30 fractions (frx), and GB treated to 50 Gy/30 frx to a lower dose PTV (PTV50) with a simultaneous integrated boost delivering a total dose of 60 Gy/30 frx to a higher dose PTV (PTV60). VMAT was planned with a single arc (VMAT1) and with an additional coplanar partial arc spanning 90° (VMAT2). We observed VMATI improving the PTV equivalent uniform dose (EUD) for BG cases (p = 0.027), improving the V95 for the PTV50 in GB cases (p = 0.026) and resulting in more conformal GB plans (p = 0.008) as compare to IMRT. However, for the GB PTV60, IMRT achieved favorable V95 over VMAT1 and VMAT2 (0.0046 and 0.008, respectively). The GB total integral dose (ID) was significantly lower with VMAT1 and VMAT2 (p = 0.049 and p = 0.006, respectively). Both VMAT1 and VMAT2 reduced the ID, however, only at the 5 Gy threshold for BG cases (p = 0.011 and 0.005, respectively). VMAT achieved a lower spinal cord maximum dose and EUD for BG cases and higher optic nerve doses, otherwise no significant differences were observed. VMAT1 yielded the fastest treatment times and least MU. We conclude that VMAT offers faster treatment delivery for complex brain tumors while maintaining similar dosimetric qualities to IMRT. Selective dosimetric advantages in terms of spinal cord sparing and lowering the ID are observed favoring the use of an additional coplanar partial arc.
Collapse
Affiliation(s)
- M. T. M. Davidson
- Department of Medical Physics, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - G. L. Masucci
- Department of Radiation Oncology, University of Toronto, Princess Margaret Hospital, Toronto, Ontario, Canada
| | - M. Follwell
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Princess Margaret Hospital, Toronto, Ontario, Canada
| | - S. J. Blake
- Department of Medical Physics, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - W. Xu
- Department of Biostatistics, University Health Network, Toronto, Ontario, Canada
| | - D. J. Moseley
- Department of Radiation Oncology, University of Toronto, Princess Margaret Hospital, Toronto, Ontario, Canada
| | - P. Sanghera
- Hall-Edwards Radiotherapy Research Group, The Cancer Centre, Queen Elizabeth Hospital, Birmingham, England
| | - C. S. Wong
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - J. Perry
- Department of Medical Oncology and Neurology, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - M. Tsao
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - A. Sahgal
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
- Department of Radiation Oncology, University of Toronto, Princess Margaret Hospital, Toronto, Ontario, Canada
| |
Collapse
|
424
|
Anderson D, Siegbahn EA, Fallone BG, Serduc R, Warkentin B. Evaluation of dose-volume metrics for microbeam radiation therapy dose distributions in head phantoms of various sizes using Monte Carlo simulations. Phys Med Biol 2012; 57:3223-48. [PMID: 22546732 DOI: 10.1088/0031-9155/57/10/3223] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
This work evaluates four dose-volume metrics applied to microbeam radiation therapy (MRT) using simulated dosimetric data as input. We seek to improve upon the most frequently used MRT metric, the peak-to-valley dose ratio (PVDR), by analyzing MRT dose distributions from a more volumetric perspective. Monte Carlo simulations were used to calculate dose distributions in three cubic head phantoms: a 2 cm mouse head, an 8 cm cat head and a 16 cm dog head. The dose distribution was calculated for a 4 × 4 mm² microbeam array in each phantom, as well as a 16 × 16 mm² array in the 8 cm cat head, and a 32 × 32 mm² array in the 16 cm dog head. Microbeam widths of 25, 50 and 75 µm and center-to-center spacings of 100, 200 and 400 µm were considered. The metrics calculated for each simulation were the conventional PVDR, the peak-to-mean valley dose ratio (PMVDR), the mean dose and the percentage volume below a threshold dose. The PVDR ranged between 3 and 230 for the 2 cm mouse phantom, and between 2 and 186 for the 16 cm dog phantom depending on geometry. The corresponding ranges for the PMVDR were much smaller, being 2-49 (mouse) and 2-46 (dog), and showed a slightly weaker dependence on phantom size and array size. The ratio of the PMVDR to the PVDR varied from 0.21 to 0.79 for the different collimation configurations, indicating a difference between the geometric dependence on outcome that would be predicted by these two metrics. For unidirectional irradiation, the mean lesion dose was 102%, 79% and 42% of the mean skin dose for the 2 cm mouse, 8 cm cat and 16 cm dog head phantoms, respectively. However, the mean lesion dose recovered to 83% of the mean skin dose in the 16 cm dog phantom in intersecting cross-firing regions. The percentage volume below a 10% dose threshold was highly dependent on geometry, with ranges for the different collimation configurations of 2-87% and 33-96% for the 2 cm mouse and 16 cm dog heads, respectively. The results of this study illustrate that different dose-volume metrics exhibit different functional dependences on MRT geometry parameters, and suggest that reliance on the PVDR as a predictor of therapeutic outcome may be insufficient.
Collapse
Affiliation(s)
- Danielle Anderson
- Department of Oncology, University of Alberta, 11560 University Avenue, Edmonton, Alberta T6G 1Z2, Canada.
| | | | | | | | | |
Collapse
|
425
|
Abstract
Despite many studies over the last 3 decades that have attempted to explicitly quantify the decision-making process for radiotherapy treatment plan evaluation, judgments of an individual plan's degree of quality are still largely subjective and can show inter- and intra-practitioner variability even if the clinical treatment goals are the same. Several factors conspire to confound the full quantification of treatment plan quality, including uncertainties in dose response of cancerous and normal tissue, the rapid pace of new technology adoption, and the human component of treatment planning. However, new developments in clinical informatics and automation are lowering the bar for developing and implementing quantitative metrics into the treatment planning process. This review discusses general strategies for using quantitative metrics in the treatment planning process and presents a case study in intensity-modulated radiation therapy planning whereby control was established on a variable system via such techniques.
Collapse
Affiliation(s)
- Kevin L Moore
- Department of Radiation Oncology, Washington University School of Medicine, St Louis, MO 63110, USA.
| | | | | | | |
Collapse
|
426
|
Skórska M, Piotrowski T. Optimization of treatment planning parameters used in tomotherapy for prostate cancer patients. Phys Med 2012; 29:273-85. [PMID: 22521735 DOI: 10.1016/j.ejmp.2012.03.007] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2011] [Revised: 03/22/2012] [Accepted: 03/27/2012] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND AND PURPOSE Tomotherapy treatment planning depends on parameters that are not used conventionally such as: field width (FW), pitch factor (PF) and modulation factor (MF). The aim of this study is to analyze the relationship between these parameters and their influence on the quality of treatment plans and beam-on time. MATERIAL AND METHODS Ten prostate cancer patients were included in the study. For each patient, two cases of irradiation were considered depending on the target volume: PTV1 included the prostate gland, seminal vesicles, pelvic lymph nodes and a 1 cm margin, whereas PTV2 included only the prostate gland with a 1 cm margin. For each patient and each case of irradiation (PTV1 and PTV2) 8 treatment plans were created - all consisted of a different combination of planning parameters (FW = 1.05, 2.5, 5 cm; PF = 0.107, 0.215, 0.43; MF = 1.5, 2.5, 3.5). Default values used in this study were FW = 2.5 cm, PF = 0.215 and MF = 2.5. Hence, for plans with different FWs, parameters of PF and MF were 0.215 and 2.5, respectively; for different PFs, FW and MF were 2.5 and 2.5, respectively; finally for different MFs, FW and PF were 2.5 and 0.215, respectively. The reference plan was optimized for FW = 1.05 cm, PF = 0.107 and MF = 3.5, which was assumed to result in the best dose distribution and the longest treatment time. As a result, 160 plans were created. Each plan was analyzed for dose distribution and execution time. RESULTS AND CONCLUSION : Treatment plans with FW of 5 cm resulted in the shortest execution time compromising the dose distribution. Moreover, the dose fall off in the longitudinal direction was not sharp. FW of 1.05 cm and PF of 0.107 were not recommended for routine prostate plans due to long execution time, which was 3 times longer than for plans with FW = 5 cm. There was no substantial decrease of irradiation time when PF was increased from 0.215 to 0.43 for both cases (PTV1 and PTV2); however, the dose distribution was slightly compromised. Finally, decreasing MF from 2.5 to 1.5 was useless because it did not change the beam-on time; however, it did remarkably decrease the dose distribution. Nevertheless, increasing MF up to 3.5 could be considered. The lowest EUD for the rectum and intestines, could be observed for PF = 0.107. For the other plans the differences were rather small (the EUD was almost the same). By reducing PF from 0.43 to 0.107 or FW from 5 to 1.05 the EUD for bladder (in PTV1 case) decreased by 3.13% and 2.60%. When PTV2 was a target volume, the EUD for bladder decreased by 4.54% and 3.43% when FW was changed from 5 to 1.05 and MF from 1.5 to 3.5, respectively. For optimal balance between beam-on time and dose distribution in OARs for routine patients, the authors would suggest to use: FW = 2.5, PF = 0.215 and MF = 2.5.
Collapse
Affiliation(s)
- M Skórska
- Department of Medical Physics, Greater Poland Cancer Centre, Garbary 15, 61-866 Poznan, Poland.
| | | |
Collapse
|
427
|
Daly ME, Luxton G, Choi CY, Gibbs IC, Chang SD, Adler JR, Soltys SG. Normal Tissue Complication Probability Estimation by the Lyman-Kutcher-Burman Method Does Not Accurately Predict Spinal Cord Tolerance to Stereotactic Radiosurgery. Int J Radiat Oncol Biol Phys 2012; 82:2025-32. [DOI: 10.1016/j.ijrobp.2011.03.004] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2010] [Revised: 01/26/2011] [Accepted: 03/11/2011] [Indexed: 11/29/2022]
|
428
|
Stanic S, Mathai M, Cui J, Purdy JA, Valicenti RK. Relationship Between Pelvic Organ-at-Risk Dose and Clinical Target Volume in Postprostatectomy Patients Receiving Intensity-Modulated Radiotherapy. Int J Radiat Oncol Biol Phys 2012; 82:1897-902. [DOI: 10.1016/j.ijrobp.2010.10.033] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2010] [Revised: 09/10/2010] [Accepted: 10/12/2010] [Indexed: 10/18/2022]
|
429
|
Censor Y, Unkelbach J. From analytic inversion to contemporary IMRT optimization: radiation therapy planning revisited from a mathematical perspective. Phys Med 2012; 28:109-18. [PMID: 21616694 PMCID: PMC3164927 DOI: 10.1016/j.ejmp.2011.04.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2009] [Revised: 04/11/2011] [Accepted: 04/14/2011] [Indexed: 12/22/2022] Open
Abstract
In this paper we look at the development of radiation therapy treatment planning from a mathematical point of view. Historically, planning for Intensity-Modulated Radiation Therapy (IMRT) has been considered as an inverse problem. We discuss first the two fundamental approaches that have been investigated to solve this inverse problem: Continuous analytic inversion techniques on one hand, and fully-discretized algebraic methods on the other hand. In the second part of the paper, we review another fundamental question which has been subject to debate from the beginning of IMRT until the present day: The rotation therapy approach versus fixed angle IMRT. This builds a bridge from historic work on IMRT planning to contemporary research in the context of Intensity-Modulated Arc Therapy (IMAT).
Collapse
Affiliation(s)
- Yair Censor
- Department of Mathematics, University of Haifa, Mt. Carmel, Haifa 31905, Israel
| | - Jan Unkelbach
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, 02114 USA
| |
Collapse
|
430
|
Kim B, Park HC, Oh D, Shin EH, Ahn YC, Kim J, Han Y. Development of the DVH management software for the biologically-guided evaluation of radiotherapy plan. Radiat Oncol J 2012; 30:43-8. [PMID: 23120743 PMCID: PMC3475962 DOI: 10.3857/roj.2012.30.1.43] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2012] [Revised: 03/22/2012] [Accepted: 03/26/2012] [Indexed: 12/20/2022] Open
Abstract
Purpose To develop the dose volume histogram (DVH) management software which guides the evaluation of radiotherapy (RT) plan of a new case according to the biological consequences of the DVHs from the previously treated patients. Materials and Methods We determined the radiation pneumonitis (RP) as an biological response parameter in order to develop DVH management software. We retrospectively reviewed the medical records of lung cancer patients treated with curative 3-dimensional conformal radiation therapy (3D-CRT). The biological event was defined as RP of the Radiation Therapy Oncology Group (RTOG) grade III or more. Results The DVH management software consisted of three parts (pre-existing DVH database, graphical tool, and Pinnacle3 script). The pre-existing DVH data were retrieved from 128 patients. RP events were tagged to the specific DVH data through retrospective review of patients' medical records. The graphical tool was developed to present the complication histogram derived from the pre-existing database (DVH and RP) and was implemented into the radiation treatment planning (RTP) system, Pinnacle3 v8.0 (Phillips Healthcare). The software was designed for the pre-existing database to be updated easily by tagging the specific DVH data with the new incidence of RP events at the time of patients' follow-up. Conclusion We developed the DVH management software as an effective tool to incorporate the phenomenological consequences derived from the pre-existing database in the evaluation of a new RT plan. It can be used not only for lung cancer patients but also for the other disease site with different toxicity parameters.
Collapse
Affiliation(s)
- Bokyong Kim
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | | | | | | | | | | | | |
Collapse
|
431
|
Bazan JG, Luxton G, Mok EC, Koong AC, Chang DT. Normal tissue complication probability modeling of acute hematologic toxicity in patients treated with intensity-modulated radiation therapy for squamous cell carcinoma of the anal canal. Int J Radiat Oncol Biol Phys 2012; 84:700-6. [PMID: 22414279 DOI: 10.1016/j.ijrobp.2011.12.072] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2011] [Revised: 12/20/2011] [Accepted: 12/21/2011] [Indexed: 11/25/2022]
Abstract
PURPOSE To identify dosimetric parameters that correlate with acute hematologic toxicity (HT) in patients with squamous cell carcinoma of the anal canal treated with definitive chemoradiotherapy (CRT). METHODS AND MATERIALS We analyzed 33 patients receiving CRT. Pelvic bone (PBM) was contoured for each patient and divided into subsites: ilium, lower pelvis (LP), and lumbosacral spine (LSS). The volume of each region receiving at least 5, 10, 15, 20, 30, and 40 Gy was calculated. Endpoints included grade ≥3 HT (HT3+) and hematologic event (HE), defined as any grade ≥2 HT with a modification in chemotherapy dose. Normal tissue complication probability (NTCP) was evaluated with the Lyman-Kutcher-Burman (LKB) model. Logistic regression was used to test associations between HT and dosimetric/clinical parameters. RESULTS Nine patients experienced HT3+ and 15 patients experienced HE. Constrained optimization of the LKB model for HT3+ yielded the parameters m = 0.175, n = 1, and TD(50) = 32 Gy. With this model, mean PBM doses of 25 Gy, 27.5 Gy, and 31 Gy result in a 10%, 20%, and 40% risk of HT3+, respectively. Compared with patients with mean PBM dose of <30 Gy, patients with mean PBM dose ≥30 Gy had a 14-fold increase in the odds of developing HT3+ (p = 0.005). Several low-dose radiation parameters (i.e., PBM-V10) were associated with the development of HT3+ and HE. No association was found with the ilium, LP, or clinical factors. CONCLUSIONS LKB modeling confirms the expectation that PBM acts like a parallel organ, implying that the mean dose to the organ is a useful predictor for toxicity. Low-dose radiation to the PBM was also associated with clinically significant HT. Keeping the mean PBM dose <22.5 Gy and <25 Gy is associated with a 5% and 10% risk of HT, respectively.
Collapse
Affiliation(s)
- Jose G Bazan
- Department of Radiation Oncology, Stanford University, Stanford, CA 94305-5847, USA
| | | | | | | | | |
Collapse
|
432
|
Anderson N, Lawford C, Khoo V, Rolfo M, Joon DL, Wada M. Improved normal tissue sparing in head and neck radiotherapy using biological cost function based-IMRT. Technol Cancer Res Treat 2012; 10:575-83. [PMID: 22066597 PMCID: PMC4509883 DOI: 10.1177/153303461101000607] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
Abstract
Intensity-modulated radiotherapy (IMRT) has reduced the impact of acute and late toxicities associated with head and neck radiotherapy. Treatment planning system (TPS) advances in biological cost function based optimization (BBO) and improved segmentation techniques have increased organ at risk (OAR) sparing compared to conventional dose-based optimization (DBO). A planning study was undertaken to compare OAR avoidance in DBO and BBO treatment planning. Simultaneous integrated boost treatment plans were produced for 10 head and neck patients using both planning systems. Plans were compared for tar get coverage and OAR avoidance. Comparisons were made using the BBO TPS Monte Carlo dose engine to eliminate differences due to inherent algorithms. Target coverage (V95%) was maintained for both solutions. BBO produced lower OAR doses, with statistically significant improvement to left (12.3%, p = 0.005) and right parotid mean dose (16.9%, p = 0.004), larynx V50 Gy (71.0%, p = 0.005), spinal cord (21.9%, p < 0.001) and brain stem dose maximums (31.5%, p = 0.002). This study observed improved OAR avoidance with BBO planning. Further investigations will be undertaken to review any clinical benefit of this improved planned dosimetry.
Collapse
Affiliation(s)
- N Anderson
- Department of Radiation Oncology, Austin Health, Heidelberg Heights, Victoria, Australia.
| | | | | | | | | | | |
Collapse
|
433
|
Pedicini P, Caivano R, Fiorentino A, Strigari L, Califano G, Barbieri V, Sanpaolo P, Castaldo G, Benassi M, Fusco V. Comparative dosimetric and radiobiological assessment among a nonstandard RapidArc, standard RapidArc, classical intensity-modulated radiotherapy, and 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecologic cancer. Med Dosim 2012; 37:347-52. [PMID: 22382087 DOI: 10.1016/j.meddos.2011.11.009] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2011] [Revised: 11/16/2011] [Accepted: 11/29/2011] [Indexed: 11/26/2022]
Abstract
To evaluate a nonstandard RapidArc (RA) modality as alternative to high-dose-rate brachytherapy (HDR-BRT) or IMRT treatments of the vaginal vault in patients with gynecological cancer (GC). Nonstandard (with vaginal applicator) and standard (without vaginal applicator) RapidArc plans for 27 women with GC were developed to compare with HDR-BRT and IMRT. Dosimetric and radiobiological comparison were performed by means of dose-volume histogram and equivalent uniform dose (EUD) for planning target volume (PTV) and organs at risk (OARs). In addition, the integral dose and the overall treatment times were evaluated. RA, as well as IMRT, results in a high uniform dose on PTV compared with HDR-BRT. However, the average of EUD for HDR-BRT was significantly higher than those with RA and IMRT. With respect to the OARs, standard RA was equivalent of IMRT but inferior to HDR-BRT. Furthermore, nonstandard RA was comparable with IMRT for bladder and sigmoid and better than HDR-BRT for the rectum because of a significant reduction of d(2cc), d(1cc), and d(max) (p < 0.01). Integral doses were always higher than HDR-BRT, although the values were very low. Delivery times were about the same and more than double for HDR-BRT compared with IMRT and RA, respectively. In conclusion, the boost of dose on vaginal vault in patients affected by GC delivered by a nonstandard RA technique was a reasonable alternative to the conventional HDR-BRT because of a reduction of delivery time and rectal dose at substantial comparable doses for the bladder and sigmoid. However HDR-BRT provides better performance in terms of PTV coverage as evidenced by a greater EUD.
Collapse
Affiliation(s)
- Piernicola Pedicini
- Service of Medical Physics, IRCCS Regional Cancer Hospital (C.R.O.B.), Rionero in Vulture, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
434
|
Niyazi M, Söhn M, Schwarz SB, Lang P, Belka C, Ganswindt U. Radiation treatment parameters for re-irradiation of malignant glioma. Strahlenther Onkol 2012; 188:328-33. [PMID: 22349710 DOI: 10.1007/s00066-011-0055-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2011] [Accepted: 10/20/2011] [Indexed: 12/25/2022]
Abstract
BACKGROUND AND PURPOSE Most patients with malignant glioma ultimately fail locally or loco-regionally after the first treatment, with re-irradiation being a reasonable treatment option. However, only limited data are presently available allowing for a precise selection of patients suitable for re-treatment with regard to safety and efficacy. MATERIAL AND METHODS Using the department database, 39 patients with a second course of radiation were identified. Doses to gross tumor volume (GTV), planning target volume (PTV), and relevant organs at risk (OARs; brainstem, optic chiasm, optic nerves, brain) were retrospectively analyzed and correlated to outcome parameters. Relevant treatment parameters including D(max), D(min), D(mean), and volume (ml) were obtained. Equivalent uniform dose (EUD) values were calculated for the tumor and OARs. To address the issue of radiation necrosis/leukoencephalopathy posttherapeutic MRI images were routinely examined every 3 months. RESULTS Median follow-up was 147 days. The time interval between first and second irradiation was regularly greater than 6 months. Median EUDs to the OARs were 11.9 Gy (range 0.7-27.4 Gy) to the optic chiasm, 17.6 Gy (range 0.7-43.0 Gy) to the brainstem, 4.9/2.1 Gy (range 0.3-24.5 Gy) to the right/left optic nerve, and 29.4 Gy (range 25.2-32.5 Gy) to the brain. No correlation between treated volume and survival was observed. Cold spots and dose did not correlate with survival. Re-irradiated volumes were treated with on average lower doses if they were larger and vice versa. CONCLUSION In general, re-irradiation is a safe and feasible re-treatment option. No relevant toxicity was observed after re-irradiation in our patient cohort during follow-up. In this regard, this analysis provides baseline data for the selection of putative patients. EUD values are derived and may serve as reference for further studies, including intensity-modulated radiotherapy (IMRT) protocols.
Collapse
Affiliation(s)
- M Niyazi
- Department of Radiation Oncology, Ludwig-Maximilians-University, Marchioninistr. 15, 81377, Munich, Germany.
| | | | | | | | | | | |
Collapse
|
435
|
Gagne NL, Leonard KL, Huber KE, Mignano JE, Duker JS, Laver NV, Rivard MJ. BEDVH-A method for evaluating biologically effective dose volume histograms: Application to eye plaque brachytherapy implants. Med Phys 2012; 39:976-83. [DOI: 10.1118/1.3679010] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
436
|
Chen W, Unkelbach J, Trofimov A, Madden T, Kooy H, Bortfeld T, Craft D. Including robustness in multi-criteria optimization for intensity-modulated proton therapy. Phys Med Biol 2012; 57:591-608. [PMID: 22222720 DOI: 10.1088/0031-9155/57/3/591] [Citation(s) in RCA: 120] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
We present a method to include robustness in a multi-criteria optimization (MCO) framework for intensity-modulated proton therapy (IMPT). The approach allows one to simultaneously explore the trade-off between different objectives as well as the trade-off between robustness and nominal plan quality. In MCO, a database of plans each emphasizing different treatment planning objectives, is pre-computed to approximate the Pareto surface. An IMPT treatment plan that strikes the best balance between the different objectives can be selected by navigating on the Pareto surface. In our approach, robustness is integrated into MCO by adding robustified objectives and constraints to the MCO problem. Uncertainties (or errors) of the robust problem are modeled by pre-calculated dose-influence matrices for a nominal scenario and a number of pre-defined error scenarios (shifted patient positions, proton beam undershoot and overshoot). Objectives and constraints can be defined for the nominal scenario, thus characterizing nominal plan quality. A robustified objective represents the worst objective function value that can be realized for any of the error scenarios and thus provides a measure of plan robustness. The optimization method is based on a linear projection solver and is capable of handling large problem sizes resulting from a fine dose grid resolution, many scenarios, and a large number of proton pencil beams. A base-of-skull case is used to demonstrate the robust optimization method. It is demonstrated that the robust optimization method reduces the sensitivity of the treatment plan to setup and range errors to a degree that is not achieved by a safety margin approach. A chordoma case is analyzed in more detail to demonstrate the involved trade-offs between target underdose and brainstem sparing as well as robustness and nominal plan quality. The latter illustrates the advantage of MCO in the context of robust planning. For all cases examined, the robust optimization for each Pareto optimal plan takes less than 5 min on a standard computer, making a computationally friendly interface possible to the planner. In conclusion, the uncertainty pertinent to the IMPT procedure can be reduced during treatment planning by optimizing plans that emphasize different treatment objectives, including robustness, and then interactively seeking for a most-preferred one from the solution Pareto surface.
Collapse
Affiliation(s)
- Wei Chen
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
| | | | | | | | | | | | | |
Collapse
|
437
|
Beyzadeoglu M, Ozyigit G, Selek U, Selek U. Radiobiology. Radiat Oncol 2012. [DOI: 10.1007/978-3-642-27988-1_2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
|
438
|
Sanpaolo P, Barbieri V, Genovesi D, Fusco V, Ausili Cèfaro G. Biologically effective dose and breast cancer conservative treatment: is duration of radiation therapy really important? Breast Cancer Res Treat 2011; 134:81-7. [PMID: 22203436 DOI: 10.1007/s10549-011-1932-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2011] [Accepted: 12/17/2011] [Indexed: 11/28/2022]
Abstract
To evaluate if biologically effective dose (BED), and in particular the duration of radiation treatment, has an effect on local relapse risk. Between January 2000 and December 2008 a total of 762 patients with T1-2 N0/+ breast cancer was treated with breast-conserving surgery and radiotherapy, with and without hormone therapy and chemotherapy. Adjuvant radiation therapy was administered to a total dose of 60-66 Gy in 30-33 fractions. The computed BEDs were divided in four groups: <43.1, 43.1-44.9, 45.0-46.1, and >46.1 Gy (A-D, respectively). Kaplan-Meier method was used to calculate local relapse rates. Cox regression method was used to identify prognostic factors of local relapse. Evaluated variables were age, tumor histology, tumor size, surgical margin status, axillary nodal status, tumor grading, adjuvant therapies, adjuvant chemotherapy alone, adjuvant hormone therapy alone, adjuvant anthracyclines, and BEDs values. 8-year local relapse rates were 18.0% for group A, 8.5% for group B, 4.6% for group C, and 2.7% for group D (P=0.008). Multivariate Cox regression analysis showed that BEDs values were associated with higher local relapse risk (P=0.001). In our study, a prolongation of radiotherapy treatment, intended as a lower BED value, after breast-conserving surgery is associated with an increased risk of local relapse. Considering the wide range of results published in other studies, hypofractionation for breast cancer should be considered, at the moment, feasible in selected patients.
Collapse
Affiliation(s)
- Pietro Sanpaolo
- Radiation Oncology Department, CROB, Via Padre Pio 1, 85028, Rionero in Vulture, Potenza, Italy.
| | | | | | | | | |
Collapse
|
439
|
Diot Q, Kavanagh B, Timmerman R, Miften M. Biological-based optimization and volumetric modulated arc therapy delivery for stereotactic body radiation therapy. Med Phys 2011; 39:237-45. [DOI: 10.1118/1.3668059] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
|
440
|
A comparison of several modulated radiotherapy techniques for head and neck cancer and dosimetric validation of VMAT. Radiother Oncol 2011; 101:388-93. [DOI: 10.1016/j.radonc.2011.08.023] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2010] [Revised: 08/25/2011] [Accepted: 08/25/2011] [Indexed: 11/22/2022]
|
441
|
Wiklund K, Toma-Dasu I, Lind BK. The influence of dose heterogeneity on tumour control probability in fractionated radiation therapy. Phys Med Biol 2011; 56:7585-600. [DOI: 10.1088/0031-9155/56/23/016] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
442
|
Mihaylov IB, Curran B, Sternick E. The effect of gantry spacing resolution on plan quality in a single modulated arc optimization. J Appl Clin Med Phys 2011; 12:3603. [PMID: 22089019 PMCID: PMC5718730 DOI: 10.1120/jacmp.v12i4.3603] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2011] [Revised: 05/31/2011] [Accepted: 06/02/2011] [Indexed: 11/23/2022] Open
Abstract
Volumetric‐modulated arc technique (VMAT) is an efficient form of IMRT delivery. It is advantageous over conventional IMRT in terms of treatment delivery time. This study investigates the relation between the number of segments and plan quality in VMAT optimization for a single modulated arc. Five prostate, five lung, and five head‐and‐neck (HN) patient plans were studied retrospectively. For each case, four VMAT plans were generated. The plans differed only in the number of control points used in the optimization process. The control points were spaced 2°, 3°, 4°, and 6° apart, respectively. All of the optimization parameters were the same among the four schemes. The 2° spacing plan was used as a reference to which the other three plans were compared. The plan quality was assessed by comparison of dose indices (DIs) and generalized equivalent uniform doses (gEUDs) for targets and critical structures. All optimization schemes generated clinically acceptable plans. The differences between the majority of reference and compared DIs and gEUDs were within 3%. DIs and gEUDs which differed in excess of 3% corresponded to dose levels well below the organ tolerances. The DI and the gEUD differences increased with an increase in plan complexity from prostates to HNs. Optimization with gantry spacing resolution of 4° seems to be a very balanced alternative between plan quality and plan complexity. PACS number: 87.55.de
Collapse
Affiliation(s)
- Ivaylo B Mihaylov
- Department of Radiation Oncology, Rhode Island Hospital/Brown Medical Center, Providence, RI 02903, USA.
| | | | | |
Collapse
|
443
|
Li R, Xing L. Bridging the gap between IMRT and VMAT: dense angularly sampled and sparse intensity modulated radiation therapy. Med Phys 2011; 38:4912-9. [PMID: 21978036 DOI: 10.1118/1.3618736] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To propose an alternative radiation therapy (RT) planning and delivery scheme with optimal angular beam sampling and intrabeam modulation for improved dose distribution while maintaining high delivery efficiency. METHODS In the proposed approach, coined as dense angularly sampled and sparse intensity modulated RT (DASSIM-RT), a large number of beam angles are used to increase the angular sampling, leading to potentially more conformal dose distributions as compared to conventional IMRT. At the same time, intensity modulation of the incident beams is simplified to eliminate the dispensable segments, compensating the increase in delivery time caused by the increased number of beams and facilitating the plan delivery. In a sense, the proposed approach shifts and transforms, in an optimal fashion, some of the beam segments in conventional IMRT to the added beams. For newly available digital accelerators, the DASSIM-RT delivery can be made very efficient by concatenating the beams so that they can be delivered sequentially without operator's intervention. Different from VMAT, the level of intensity modulation in DASSIS-RT is field specific and optimized to meet the need of each beam direction. Three clinical cases (a head and neck (HN) case, a pancreas case, and a lung case) are used to evaluate the proposed RT scheme. DASSIM-RT, VMAT, and conventional IMRT plans are compared quantitatively in terms of the conformality index (CI) and delivery efficiency. RESULTS Plan quality improves generally with the number and intensity modulation of the incident beams. For a fixed number of beams or fixed level of intensity modulation, the improvement saturates after the intensity modulation or number of beams reaches to a certain level. An interplay between the two variables is observed and the saturation point depends on the values of both variables. For all the cases studied here, the CI of DASSIM-RT with 15 beams and 5 intensity levels (0.90, 0.79, and 0.84 for the HN, pancreas, and lung cases, respectively) is similar with that of conventional IMRT with seven beams and ten intensity levels (0.88, 0.79, and 0.83) and is higher than that of single-arc VMAT (0.75, 0.75, and 0.82). It is also found that the DASSIM-RT plans generally have better sparing of organs-at-risk than IMRT plans. It is estimated that the dose delivery time of DASSIM-RT with 15 beams and 5 intensity levels is about 4.5, 4.4, and 4.2 min for the HN, pancreas, and lung case, respectively, similar to that of IMRT plans with 7 beams and 10 intensity levels. CONCLUSION DASSIS-RT bridges the gap between IMRT and VMAT and allows optimal sampling of angular space and intrabeam modulation, thus it provides improved conformity in dose distributions while maintaining high delivery efficiency.
Collapse
Affiliation(s)
- Ruijiang Li
- Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA 94305-5847, USA
| | | |
Collapse
|
444
|
Fiege J, McCurdy B, Potrebko P, Champion H, Cull A. PARETO: A novel evolutionary optimization approach to multiobjective IMRT planning. Med Phys 2011; 38:5217-29. [PMID: 21978066 DOI: 10.1118/1.3615622] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Abstract
PURPOSE In radiation therapy treatment planning, the clinical objectives of uniform high dose to the planning target volume (PTV) and low dose to the organs-at-risk (OARs) are invariably in conflict, often requiring compromises to be made between them when selecting the best treatment plan for a particular patient. In this work, the authors introduce Pareto-Aware Radiotherapy Evolutionary Treatment Optimization (pareto), a multiobjective optimization tool to solve for beam angles and fluence patterns in intensity-modulated radiation therapy (IMRT) treatment planning. METHODS pareto is built around a powerful multiobjective genetic algorithm (GA), which allows us to treat the problem of IMRT treatment plan optimization as a combined monolithic problem, where all beam fluence and angle parameters are treated equally during the optimization. We have employed a simple parameterized beam fluence representation with a realistic dose calculation approach, incorporating patient scatter effects, to demonstrate feasibility of the proposed approach on two phantoms. The first phantom is a simple cylindrical phantom containing a target surrounded by three OARs, while the second phantom is more complex and represents a paraspinal patient. RESULTS pareto results in a large database of Pareto nondominated solutions that represent the necessary trade-offs between objectives. The solution quality was examined for several PTV and OAR fitness functions. The combination of a conformity-based PTV fitness function and a dose-volume histogram (DVH) or equivalent uniform dose (EUD) -based fitness function for the OAR produced relatively uniform and conformal PTV doses, with well-spaced beams. A penalty function added to the fitness functions eliminates hotspots. Comparison of resulting DVHs to those from treatment plans developed with a single-objective fluence optimizer (from a commercial treatment planning system) showed good correlation. Results also indicated that pareto shows promise in optimizing the number of beams. CONCLUSIONS This initial evaluation of the evolutionary optimization software tool pareto for IMRT treatment planning demonstrates feasibility and provides motivation for continued development. Advantages of this approach over current commercial methods for treatment planning are many, including: (1) fully automated optimization that avoids human controlled iterative optimization and potentially improves overall process efficiency, (2) formulation of the problem as a true multiobjective one, which provides an optimized set of Pareto nondominated solutions refined over hundreds of generations and compiled from thousands of parameter sets explored during the run, and (3) rapid exploration of the final nondominated set accomplished by a graphical interface used to select the best treatment option for the patient.
Collapse
Affiliation(s)
- Jason Fiege
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba, Canada.
| | | | | | | | | |
Collapse
|
445
|
Henríquez FC, Castrillón SV. A quality index for equivalent uniform dose. J Med Phys 2011; 36:126-32. [PMID: 21897557 PMCID: PMC3159218 DOI: 10.4103/0971-6203.83466] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2010] [Revised: 12/12/2010] [Accepted: 02/18/2011] [Indexed: 12/25/2022] Open
Abstract
Equivalent uniform dose (EUD) is the absorbed dose that, when homogeneously given to a tumor, yields the same mean surviving clonogen number as the given non-homogeneous irradiation. EUD is used as an evaluation tool under the assumption that two plans with the same value of EUD are equivalent, and their biological effect on the tumor (clonogen survival) would be the same as the one of a homogeneous irradiation of absorbed dose EUD. In this work, this assumption has been studied, and a figure of merit of its applicability has been obtained. Distributions of surviving clonogen number for homogeneous and non-homogeneous irradiations are found to be different even if their mean values are the same, the figure of merit being greater when there is a wider difference, and the equivalence assumption being less valid. Therefore, EUD can be closer to a uniform dose for some cases than for other ones (high α values, extreme heterogeneity), and the accuracy of the radiobiological indices obtained for evaluation, could be affected. Results show that the equivalence is very sensitive to the choice of radiobiological parameters, and this conclusion has been derived from mathematical properties of EUD.
Collapse
|
446
|
Zhang GG, Ku L, Dilling TJ, Stevens CW, Zhang RR, Li W, Feygelman V. Volumetric modulated arc planning for lung stereotactic body radiotherapy using conventional and unflattened photon beams: a dosimetric comparison with 3D technique. Radiat Oncol 2011; 6:152. [PMID: 22070866 PMCID: PMC3354344 DOI: 10.1186/1748-717x-6-152] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2011] [Accepted: 11/09/2011] [Indexed: 01/10/2023] Open
Abstract
Purpose Frequently, three-dimensional (3D) conformal beams are used in lung cancer stereotactic body radiotherapy (SBRT). Recently, volumetric modulated arc therapy (VMAT) was introduced as a new treatment modality. VMAT techniques shorten delivery time, reducing the possibility of intrafraction target motion. However dose distributions can be quite different from standard 3D therapy. This study quantifies those differences, with focus on VMAT plans using unflattened photon beams. Methods A total of 15 lung cancer patients previously treated with 3D or VMAT SBRT were randomly selected. For each patient, non-coplanar 3D, coplanar and non-coplanar VMAT and flattening filter free VMAT (FFF-VMAT) plans were generated to meet the same objectives with 50 Gy covering 95% of the PTV. Two dynamic arcs were used in each VMAT plan. The couch was set at ± 5° to the 0° straight position for the two non-coplanar arcs. Pinnacle version 9.0 (Philips Radiation Oncology, Fitchburg WI) treatment planning system with VMAT capabilities was used. We analyzed the conformity index (CI), which is the ratio of the total volume receiving at least the prescription dose to the target volume receiving at least the prescription dose; the conformity number (CN) which is the ratio of the target coverage to CI; and the gradient index (GI) which is the ratio of the volume of 50% of the prescription isodose to the volume of the prescription isodose; as well as the V20, V5, and mean lung dose (MLD). Paired non-parametric analysis of variance tests with post-tests were performed to examine the statistical significance of the differences of the dosimetric indices. Results Dosimetric indices CI, CN and MLD all show statistically significant improvement for all studied VMAT techniques compared with 3D plans (p < 0.05). V5 and V20 show statistically significant improvement for the FFF-VMAT plans compared with 3D (p < 0.001). GI is improved for the FFF-VMAT and the non-coplanar VMAT plans (p < 0.01 and p < 0.05 respectively) while the coplanar VMAT plans do not show significant difference compared to 3D plans. Dose to the target is typically more homogeneous in FFF-VMAT plans. FFF-VMAT plans require more monitor units than 3D or non-coplanar VMAT ones. Conclusion Besides the advantage of faster delivery times, VMAT plans demonstrated better conformity to target, sharper dose fall-off in normal tissues and lower dose to normal lung than the 3D plans for lung SBRT. More monitor units are often required for FFF-VMAT plans.
Collapse
|
447
|
Ma L, Lee L, Barani I, Hwang A, Fogh S, Nakamura J, McDermott M, Sneed P, Larson DA, Sahgal A. Shot sequencing based on biological equivalent dose considerations for multiple isocenter Gamma Knife radiosurgery. Phys Med Biol 2011; 56:7247-56. [DOI: 10.1088/0031-9155/56/22/015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
448
|
McQuaid D, Bortfeld T. 4D planning over the full course of fractionation: assessment of the benefit of tumor trailing. Phys Med Biol 2011; 56:6935-49. [PMID: 22008696 DOI: 10.1088/0031-9155/56/21/011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
449
|
Appelt AL, Vogelius IR. A method to adjust radiation dose-response relationships for clinical risk factors. Radiother Oncol 2011; 102:352-4. [PMID: 21981874 DOI: 10.1016/j.radonc.2011.08.031] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2011] [Revised: 08/15/2011] [Accepted: 08/27/2011] [Indexed: 12/25/2022]
Abstract
Several clinical risk factors for radiation induced toxicity have been identified in the literature. Here, we present a method to quantify the effect of clinical risk factors on radiation dose-response curves and apply the method to adjust the dose-response for radiation pneumonitis for patients with/without pre-existing pulmonary co-morbidities.
Collapse
Affiliation(s)
- Ane L Appelt
- Department of Oncology, University of Southern Denmark, Vejle Sygehus, Denmark.
| | | |
Collapse
|
450
|
Stereotactic body radiation therapy in non-small-cell lung cancer: linking radiobiological modeling and clinical outcome. Am J Clin Oncol 2011; 34:432-41. [PMID: 20539207 DOI: 10.1097/coc.0b013e3181df4b3f] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
For patients with peripheral, early-stage non-small-cell lung cancer, it has been found feasible to deliver 5 or fewer fractions of large doses through stereotactic body radiation therapy (SBRT) without causing severe early or late injury and with impressive tumor control. In this review, we employ radiobiological modeling with the linear quadratic formulation to explore the adequacy of various dose schedules used for tumor control in the lung as supported by clinical evidence, the influence of dose distribution and delivery time on local control, and how to decrease the likelihood of severe toxicity following SBRT. Furthermore, the validity of the linear quadratic formalism in the high dose range of SBRT for lung cancer is explored.
Collapse
|