Tsubouchi T, Beltran CJ, Yagi M, Hamatani N, Takashina M, Shimizu S, Kanai T, Furutani KM. Beam delivery characteristics of the Hitachi carbon ion scanning system at Osaka Heavy Ion Medical Accelerator in Kansai (HIMAK). Med Phys 2024; 51:2239-2250. [PMID: 37877590 DOI: 10.1002/mp.16791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 09/15/2023] [Accepted: 09/28/2023] [Indexed: 10/26/2023] Open
Abstract
BACKGROUND Using the pencil beam raster scanning method employed at most carbon beam treatment facilities, spots can be moved without interrupting the beam, allowing for the delivery of a dose between spots (move dose). This technique is also known as Dose-Driven-Continuous-Scanning (DDCS). To minimize its impact on HIMAK patient dosimetry, there's an upper limit to the move dose. Spots within a layer are grouped into sets, or "break points," allowing continuous irradiation. The beam is turned off when transitioning between sets or at the end of a treatment layer or spill. The control system beam-off is accomplished by turning off the RF Knockout (RFKO) extraction and after a brief delay the High Speed Steering Magnet (HSST) redirects the beam transport away from isocenter to a beam dump. PURPOSE The influence of the move dose and beam on/off control on the dose distribution and irradiation time was evaluated by measurements never before reported and modelled for Hitachi Carbon DDCS. METHOD We conducted fixed-point and scanning irradiation experiments at three different energies, both with and without breakpoints. For fixed-point irradiation, we utilized a 2D array detector and an oscilloscope to measure beam intensity over time. The oscilloscope data enabled us to confirm beam-off and beam-on timing due to breakpoints, as well as the relative timing of the RFKO signal, HSST signal, and dose monitor (DM) signals. From these measurements, we analyzed and modelled the temporal characteristics of the beam intensity. We also developed a model for the spot shape and amplitude at isocenter occurring after the beam-off signal which we called flap dose and its dependence on beam intensity. In the case of scanning irradiation, we measured move doses using the 2D array detector and compared these measurements with our model. RESULT We observed that the most dominant time variation of the beam intensity was at 1 kHz and its harmonic frequencies. Our findings revealed that the derived beam intensity cannot reach the preset beam intensity when each spot belongs to different breakpoints. The beam-off time due to breakpoints was approximately 100 ms, while the beam rise time and fall time (tdecay ) were remarkably fast, about 10 ms and 0.2 ms, respectively. Moreover, we measured the time lag (tdelay ) of approximately 0.2 ms between the RFKO and HSST signals. Since tdelay ≈ tdecay at HIMAK then the HSST is activated after the residual beam intensity, resulting in essentially zero flap dose at isocenter from the HSST. Our measurements of the move dose demonstrated excellent agreement with the modelled move dose. CONCLUSION We conducted the first move dose measurement for a Hitachi Carbon synchrotron, and our findings, considering beam on/off control details, indicate that Hitachi's carbon synchrotron provides a stable beam at HIMAK. Our work suggests that measuring both move dose and flap dose should be part of the commissioning process and possibly using our model in the Treatment Planning System (TPS) for new facilities with treatment delivery control systems with higher beam intensities and faster beam-off control.
Collapse
Affiliation(s)
- Toshiro Tsubouchi
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Osaka, Japan
| | - Chris J Beltran
- Department of Carbon Ion Radiotherapy, Osaka University Graduate School of Medicine, Osaka, Japan
- Department of Radiation Oncology, Division of Medical Physics, Mayo Clinic, Jacksonville, Florida, USA
| | - Masashi Yagi
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Osaka, Japan
- Department of Carbon Ion Radiotherapy, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Noriaki Hamatani
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Osaka, Japan
| | - Masaaki Takashina
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Osaka, Japan
| | - Shinichi Shimizu
- Department of Carbon Ion Radiotherapy, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Tatsuaki Kanai
- Department of Carbon Ion Radiotherapy, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Keith M Furutani
- Department of Carbon Ion Radiotherapy, Osaka University Graduate School of Medicine, Osaka, Japan
- Department of Radiation Oncology, Division of Medical Physics, Mayo Clinic, Jacksonville, Florida, USA
| |
Collapse
|
2
|
Parisi A, Beltran CJ, Furutani KM. Variable RBE in proton radiotherapy: a comparative study with the predictive Mayo Clinic Florida microdosimetric kinetic model and phenomenological models of cell survival. Phys Med Biol 2023; 68:185020. [PMID: 38133518 DOI: 10.1088/1361-6560/acf43b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 08/25/2023] [Indexed: 12/23/2023]
Abstract
Objectives. (1) To examine to what extent the cell- and exposure- specific information neglected in the phenomenological proton relative biological effectiveness (RBE) models could influence the computed RBE in proton therapy. (2) To explore similarities and differences in the formalism and the results between the linear energy transfer (LET)-based phenomenological proton RBE models and the microdosimetry-based Mayo Clinic Florida microdosimetric kinetic model (MCF MKM). (3) To investigate how the relationship between the RBE and the dose-mean proton LET is affected by the proton energy spectrum and the secondary fragments.Approach. We systematically compared six selected phenomenological proton RBE models with the MCF MKM in track-segment simulations, monoenergetic proton beams in a water phantom, and two spread-out Bragg peaks. A representative comparison within vitrodata for human glioblastoma cells (U87 cell line) is also included.Main results. Marked differences were observed between the results of the phenomenological proton RBE models, as reported in previous studies. The dispersion of these models' results was found to be comparable to the spread in the MCF MKM results obtained by varying the cell-specific parameters neglected in the phenomenological models. Furthermore, while single cell-specific correlation between RBE and the dose-mean proton LET seems reasonable above 2 keVμm-1, caution is necessary at lower LET values due to the relevant contribution of secondary fragments. The comparison within vitrodata demonstrates comparable agreement between the MCF MKM predictions and the results of the phenomenological models.Significance. The study highlights the importance of considering cell-specific characteristics and detailed radiation quality information for accurate RBE calculations in proton therapy. Furthermore, these results provide confidence in the use of the MCF MKM for clonogenic survival RBE calculations in proton therapy, offering a more mechanistic approach compared to phenomenological models.
Collapse
Affiliation(s)
- Alessio Parisi
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, FL, United States of America
| | - Chris J Beltran
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, FL, United States of America
| | - Keith M Furutani
- Department of Radiation Oncology, Mayo Clinic, Jacksonville, FL, United States of America
| |
Collapse
|
3
|
Yagi M, Tsubouchi T, Hamatani N, Takashina M, Saruwatari N, Minami K, Wakisaka Y, Fujitaka S, Hirayama S, Nihongi H, Hasegawa A, Koizumi M, Shimizu S, Ogawa K, Kanai T. Validation of robust radiobiological optimization algorithms based on the mixed beam model for intensity-modulated carbon-ion therapy. PLoS One 2023; 18:e0288545. [PMID: 37506069 PMCID: PMC10381094 DOI: 10.1371/journal.pone.0288545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 06/29/2023] [Indexed: 07/30/2023] Open
Abstract
Currently, treatment planning systems (TPSs) that can compute the intensities of intensity-modulated carbon-ion therapy (IMCT) using scanned carbon-ion beams are limited. In the present study, the computational efficacy of the newly designed IMCT algorithms was analyzed for the first time based on the mixed beam model with respect to the physical and biological doses; moreover, the validity and effectiveness of the robust radiobiological optimization were verified. A dose calculation engine was independently generated to validate a clinical dose determined in the TPS. A biological assay was performed using the HSGc-C5 cell line to validate the calculated surviving fraction (SF). Both spot control (SC) and voxel-wise worst-case scenario (WC) algorithms were employed for robust radiobiological optimization followed by their application in a Radiation Therapy Oncology Group benchmark phantom under homogeneous and heterogeneous conditions and a clinical case for range and position errors. Importantly, for the first time, both SC and WC algorithms were implemented in the integrated TPS platform that can compute the intensities of IMCT using scanned carbon-ion beams for robust radiobiological optimization. For assessing the robustness, the difference between the maximum and minimum values of a dose-volume histogram index in the examined error scenarios was considered as a robustness index. The relative biological effectiveness (RBE) determined by the independent dose calculation engine exhibited a -0.6% difference compared with the RBE defined by the TPS at the isocenter, whereas the measured and the calculated SF were similar. Regardless of the objects, compared with the conventional IMCT, the robust radiobiological optimization enhanced the sensitivity of the examined error scenarios by up to 19% for the robustness index. The computational efficacy of the novel IMCT algorithms was verified according to the mixed beam model with respect to the physical and biological doses. The robust radiobiological optimizations lowered the impact of range and position uncertainties considerably in the examined scenarios. The robustness of the WC algorithm was more enhanced compared with that of the SC algorithm. Nevertheless, the SC algorithm can be used as an alternative to the WC IMCT algorithm with respect to the computational cost.
Collapse
Affiliation(s)
- Masashi Yagi
- Department of Carbon Ion Radiotherapy, Osaka University Graduate School of Medicine, Suita-shi, Osaka, Japan
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Osaka-shi, Osaka, Japan
| | - Toshiro Tsubouchi
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Osaka-shi, Osaka, Japan
| | - Noriaki Hamatani
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Osaka-shi, Osaka, Japan
| | - Masaaki Takashina
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Osaka-shi, Osaka, Japan
| | - Naoto Saruwatari
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita-shi, Osaka, Japan
| | - Kazumasa Minami
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita-shi, Osaka, Japan
| | - Yushi Wakisaka
- Department of Radiation Technology, Osaka Heavy Ion Therapy Center, Osaka-shi, Osaka, Japan
| | | | - Shusuke Hirayama
- Hitachi, Ltd., Research & Development Group, Hitachi-shi, Ibaraki, Japan
| | - Hideaki Nihongi
- Hitachi, Ltd., Healthcare Innovation Division/Healthcare Business Division, Kashiwa-shi, Chiba, Japan
| | - Azusa Hasegawa
- Department of Radiation Oncology, Osaka Heavy Ion Therapy Center, Osaka-shi, Osaka, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita-shi, Osaka, Japan
| | - Shinichi Shimizu
- Department of Carbon Ion Radiotherapy, Osaka University Graduate School of Medicine, Suita-shi, Osaka, Japan
| | - Kazuhiko Ogawa
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita-shi, Osaka, Japan
| | - Tatsuaki Kanai
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Osaka-shi, Osaka, Japan
| |
Collapse
|
4
|
Wakisaka Y, Minami K, Okada N, Tsubouchi T, Hamatani N, Yagi M, Takashina M, Kanai T. Treatment planning of carbon ion radiotherapy for prostate cancer based on cellular experiments with PC3 human prostate cancer cells. Phys Med 2023; 107:102537. [PMID: 36780791 DOI: 10.1016/j.ejmp.2023.102537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 01/10/2023] [Accepted: 01/31/2023] [Indexed: 02/13/2023] Open
Abstract
[Purpose] Treatment plans for carbon ion radiotherapy (CIRT) in Japan are designed to uniformly deliver the prescribed clinical dose based on the radiosensitivity of human salivary gland (HSG) cells to the planning target volume (PTV). However, sensitivity to carbon beams varies between cell lines, that is, it should be checked that the clinical dose distribution based on the cell radiosensitivity of the treatment site is uniform within the PTV. [Methods] We modeled the linear energy transfer (LET) dependence of the linear-quadratic (LQ) coefficients specific to prostate cancer, which accounts for the majority of CIRT. This was achieved by irradiating prostate cancer cells (PC3) with X-rays from a 4 MV-Linac and carbon beams with different LETs of 11.1-214.3 keV/μm. By using the radiosensitivity of PC3 cells derived from cellular experiments, we reconstructed prostate-cancer-specific clinical dose distributions on patient computed tomography (CT). [Results] The LQ coefficient, α, of PC3 cells was larger than that of HSG cells at low (<50 keV/μm) LET and smaller at high (>50 keV/μm) LET, which was validated by cellular experiments performed on rectangular SOBPs. The reconstructed dose distribution on patient CT was sloped when 1 fraction incident from the one side of the patient was considered, but remained uniform from the sum of 12 fractions of the left-right opposing beams (as is used in clinical practice). [Conclusion] Our study reveals the inhomogeneity of clinical doses in single-field plans calculated using the PC3 radiosensitivity data. However, this inhomogeneity is compensated by using the combination of left-right opposing beams.
Collapse
Affiliation(s)
- Yushi Wakisaka
- Osaka Heavy Ion Therapy Center, Osaka City, Osaka, Japan; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Osaka City, Osaka, Japan.
| | - Kazumasa Minami
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Osaka City, Osaka, Japan
| | - Nao Okada
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Osaka City, Osaka, Japan
| | | | | | - Masashi Yagi
- Osaka Heavy Ion Therapy Center, Osaka City, Osaka, Japan; Department of Carbon Ion Radiotherapy, Osaka University Graduate School of Medicine, Osaka City, Osaka, Japan
| | | | - Tatsuaki Kanai
- Osaka Heavy Ion Therapy Center, Osaka City, Osaka, Japan; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Osaka City, Osaka, Japan
| |
Collapse
|
5
|
Nakaji T, Kanai T, Takashina M, Matsumura A, Osaki K, Yagi M, Tsubouchi T, Hamatani N, Ogawa K. Clinical dose assessment for scanned carbon-ion radiotherapy using linear energy transfer measurements and Monte Carlo simulations. Phys Med Biol 2022; 67. [PMID: 36327456 DOI: 10.1088/1361-6560/aca003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Accepted: 11/03/2022] [Indexed: 11/06/2022]
Abstract
Objective. Dosimetric commissioning of treatment planning systems (TPS) focuses on validating the agreement of the physical dose with experimental data. For carbon-ion radiotherapy, the commissioning of the relative biological effectiveness (RBE) is necessary to predict the clinical outcome based on the radiation quality of the mixed radiation field. In this study, we proposed a approach for RBE commissioning using Monte Carlo (MC) simulations, which was further strengthen by RBE validation based on linear energy transfer (LET) measurements.Approach. First, we tuned the MC simulation based on the results of dosimetric experiments including the beam ranges, beam sizes, and MU calibrations. Furthermore, we compared simulated results to measured depth- and radial-LET distributions of the 430 MeV u-1carbon-ion spot beam with a 1.5 mm2, 36μm thick silicon detector. The measured dose-averaged LET (LETd) and RBE were compared with the simulated results. The RBE was calculated based on the mixed beam model with linear-quadratic parameters depending on the LET. Finally, TPS-calculated clinical dose profiles were validated through the tuned MC-based calculations.Main results. A 10 keVμm-1and 0.15 agreement for LETdand RBE, respectively, were found between simulation and measurement results obtained for a 2σlateral size of 430 MeV u-1carbon-ion spot beam in water. These results suggested that the tuned MC simulation can be used with acceptable precision for the RBE and LET calculations of carbon-ion spot beam within the clinical energy range. For physical and clinical doses, the TPS- and MC-based calculations showed good agreements within 1.0% at the centre of the spread-out Bragg peaks.Significance. The tuned MC simulation can accurately reproduce the actual carbon-ion beams, and it can be used to validate the physical and clinical dose distributions calculated by TPS. Moreover, the MC simulation can be used for dosimetric commissioning, including clinical doses, without LET measurements.
Collapse
Affiliation(s)
- Taku Nakaji
- QST Hospital, Quantum Life and Medical Science Directorate, National Institutes for Quantum Science and Technology (QST), 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan.,Graduate School of Medicine, Osaka University, 2-2 Yamada-oka, Suita, Osaka 565-0871, Japan
| | - Tatsuaki Kanai
- Graduate School of Medicine, Osaka University, 2-2 Yamada-oka, Suita, Osaka 565-0871, Japan.,Division of Medical Physics, Osaka Heavy Ion Therapy Center, 3-1-10 Otemae, Chuo-ku, Osaka City, Osaka 540-0008, Japan
| | - Masaaki Takashina
- Graduate School of Medicine, Osaka University, 2-2 Yamada-oka, Suita, Osaka 565-0871, Japan.,Division of Medical Physics, Osaka Heavy Ion Therapy Center, 3-1-10 Otemae, Chuo-ku, Osaka City, Osaka 540-0008, Japan
| | - Akihiko Matsumura
- Heavy Ion Medical Center, Gunma University, 3-39-22 Showa-Machi, Maebashi, Gunma 371-8511, Japan
| | - Kohei Osaki
- Graduate School of Medicine, Gunma University, 3-39-22 Showa-Machi, Maebashi, Gunma 371-8511, Japan
| | - Masashi Yagi
- Graduate School of Medicine, Osaka University, 2-2 Yamada-oka, Suita, Osaka 565-0871, Japan.,Division of Medical Physics, Osaka Heavy Ion Therapy Center, 3-1-10 Otemae, Chuo-ku, Osaka City, Osaka 540-0008, Japan
| | - Toshiro Tsubouchi
- Division of Medical Physics, Osaka Heavy Ion Therapy Center, 3-1-10 Otemae, Chuo-ku, Osaka City, Osaka 540-0008, Japan
| | - Noriaki Hamatani
- Division of Medical Physics, Osaka Heavy Ion Therapy Center, 3-1-10 Otemae, Chuo-ku, Osaka City, Osaka 540-0008, Japan
| | - Kazuhiko Ogawa
- Graduate School of Medicine, Osaka University, 2-2 Yamada-oka, Suita, Osaka 565-0871, Japan
| |
Collapse
|
6
|
The Mayo Clinic Florida Microdosimetric Kinetic Model of Clonogenic Survival: Application to Various Repair-Competent Rodent and Human Cell Lines. Int J Mol Sci 2022; 23:ijms232012491. [PMID: 36293348 PMCID: PMC9604502 DOI: 10.3390/ijms232012491] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 10/04/2022] [Accepted: 10/11/2022] [Indexed: 11/30/2022] Open
Abstract
The relative biological effectiveness (RBE) calculations used during the planning of ion therapy treatments are generally based on the microdosimetric kinetic model (MKM) and the local effect model (LEM). The Mayo Clinic Florida MKM (MCF MKM) was recently developed to overcome the limitations of previous MKMs in reproducing the biological data and to eliminate the need for ion-exposed in vitro data as input for the model calculations. Since we are considering to implement the MCF MKM in clinic, this article presents (a) an extensive benchmark of the MCF MKM predictions against corresponding in vitro clonogenic survival data for 4 rodent and 10 cell lines exposed to ions from 1H to 238U, and (b) a systematic comparison with published results of the latest version of the LEM (LEM IV). Additionally, we introduce a novel approach to derive an approximate value of the MCF MKM model parameters by knowing only the animal species and the mean number of chromosomes. The overall good agreement between MCF MKM predictions and in vitro data suggests the MCF MKM can be reliably used for the RBE calculations. In most cases, a reasonable agreement was found between the MCF MKM and the LEM IV.
Collapse
|
7
|
Yagi M, Tsubouchi T, Hamatani N, Takashina M, Maruo H, Fujitaka S, Nihongi H, Ogawa K, Kanai T. Commissioning a newly developed treatment planning system, VQA Plan, for fast-raster scanning of carbon-ion beams. PLoS One 2022; 17:e0268087. [PMID: 35536852 PMCID: PMC9089877 DOI: 10.1371/journal.pone.0268087] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 04/21/2022] [Indexed: 11/18/2022] Open
Abstract
In this study, we report our experience in commissioning a commercial treatment planning system (TPS) for fast-raster scanning of carbon-ion beams. This TPS uses an analytical dose calculation algorithm, a pencil-beam model with a triple Gaussian form for the lateral-dose distribution, and a beam splitting algorithm to consider lateral heterogeneity in a medium. We adopted the mixed beam model as the relative biological effectiveness (RBE) model for calculating the RBE values of the scanned carbon-ion beam. To validate the modeled physical dose, we compared the calculations with measurements of various relevant quantities as functions of the field size, range and width of the spread-out Bragg peak (SOBP), and depth–dose and lateral-dose profiles for a 6-mm SOBP in water. To model the biological dose, we compared the RBE calculated with the newly developed TPS to the RBE calculated with a previously validated TPS that is in clinical use and uses the same RBE model concept. We also performed patient-specific measurements to validate the dose model in clinical situations. The physical beam model reproduces the measured absolute dose at the center of the SOBP as a function of field size, range, and SOBP width and reproduces the dose profiles for a 6-mm SOBP in water. However, the profiles calculated for a heterogeneous phantom have some limitations in predicting the carbon-ion-beam dose, although the biological doses agreed well with the values calculated by the validated TPS. Using this dose model for fast-raster scanning, we successfully treated more than 900 patients from October 2018 to October 2020, with an acceptable agreement between the TPS-calculated and measured dose distributions. We conclude that the newly developed TPS can be used clinically with the understanding that it has limited accuracies for heterogeneous media.
Collapse
Affiliation(s)
- Masashi Yagi
- Department of Carbon Ion Radiotherapy, Osaka University Graduate School of Medicine, Suita-city, Osaka, Japan
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Chuo-ku, Osaka-city, Osaka, Japan
- * E-mail:
| | - Toshiro Tsubouchi
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Chuo-ku, Osaka-city, Osaka, Japan
| | - Noriaki Hamatani
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Chuo-ku, Osaka-city, Osaka, Japan
| | - Masaaki Takashina
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Chuo-ku, Osaka-city, Osaka, Japan
| | - Hiroyasu Maruo
- Department of Radiation Technology, Osaka Heavy Ion Therapy Center, Chuo-ku, Osaka-city, Osaka, Japan
| | | | - Hideaki Nihongi
- Hitachi, Ltd. Smart Life Business Management Division/Healthcare Business Division, KOIL TERRACE 3F 226-44-141-1, Wakashiba, Kashiwa-shi, Chiba, Japan
| | - Kazuhiko Ogawa
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita-city, Osaka, Japan
| | - Tatsuaki Kanai
- Department of Medical Physics, Osaka Heavy Ion Therapy Center, Chuo-ku, Osaka-city, Osaka, Japan
| |
Collapse
|
8
|
A Consistent Protocol Reveals a Large Heterogeneity in the Biological Effectiveness of Proton and Carbon-Ion Beams for Various Sarcoma and Normal-Tissue-Derived Cell Lines. Cancers (Basel) 2022; 14:cancers14082009. [PMID: 35454915 PMCID: PMC9029457 DOI: 10.3390/cancers14082009] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Revised: 04/03/2022] [Accepted: 04/07/2022] [Indexed: 01/27/2023] Open
Abstract
Simple Summary Using a consistent experimental protocol, we found a large heterogeneity in the relative biological effectiveness (RBE) values of both proton and carbon-ion beams in various sarcomas and normal-tissue-derived cell lines. Our data suggest that proton beam therapy may be more beneficial for some types of tumors. In carbon-ion therapy, for some types of tumors, large heterogeneity in RBE should prompt consideration of dose reduction or an increased dose per fraction. In particular, a higher RBE value in normal tissues requires caution. Specific dose evaluations for tumor and normal tissues are needed for both proton and carbon-ion therapies. Abstract This study investigated variations in the relative biological effectiveness (RBE) values among various sarcoma and normal-tissue-derived cell lines (normal cell line) in proton beam and carbon-ion irradiations. We used a consistent protocol that specified the timing of irradiation after plating cells and detailed the colony formation assay. We examined the cell type dependence of RBE for proton beam and carbon-ion irradiations using four human sarcoma cell lines (MG63 osteosarcoma, HT1080 fibrosarcoma, SW872 liposarcoma, and SW1353 chondrosarcoma) and three normal cell lines (HDF human dermal fibroblast, hTERT-HME1 mammary gland, and NuLi-1 bronchus epithelium). The cells were irradiated with gamma rays, proton beams at the center of the spread-out Bragg peak, or carbon-ion beams at 54.4 keV/μm linear energy transfer. In all sarcoma and normal cell lines, the average RBE values in proton beam and carbon-ion irradiations were 1.08 ± 0.11 and 2.08 ± 0.36, which were consistent with the values of 1.1 and 2.13 used in current treatment planning systems, respectively. Up to 34% difference in the RBE of the proton beam was observed between MG63 and HT1080. Similarly, a 32% difference in the RBE of the carbon-ion beam was observed between SW872 and the other sarcoma cell lines. In proton beam irradiation, normal cell lines had less variation in RBE values (within 10%), whereas in carbon-ion irradiation, RBE values differed by up to 48% between hTERT-HME1 and NuLi-1. Our results suggest that specific dose evaluations for tumor and normal tissues are necessary for treatment planning in both proton and carbon-ion therapies.
Collapse
|