1
|
Ghalkhani M, Sohouli E, Dehkordi ZS. Electrochemical sensor based on mesoporous g-C 3N 4/N-CNO/gold nanoparticles for measuring oxycodone. Sci Rep 2024; 14:17221. [PMID: 39060331 PMCID: PMC11282311 DOI: 10.1038/s41598-024-68310-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Accepted: 07/22/2024] [Indexed: 07/28/2024] Open
Abstract
Oxycodone, often used as an analgesic, is a potent opioid. While its effectiveness has been proven in the control of moderate to acute pain, excessive use of oxycodone imposes heart failure, heart palpitations, reduction of red blood cells, bone pain, and even death. Therefore, monitoring the oxycodone concentration in blood is vital for emergency care. For this purpose, a novel electrochemical sensor was designed based on a glassy carbon electrode modified with mesoporous g-C3N4 (M-C3N4), carbon nano-onions doped with nitrogen (N-CNO), and gold nanoparticles. At first, the SEM and XRD techniques were employed to characterize prepared M-C3N4 and N-CNO samples. The electro-oxidation behavior of the oxycodone was evaluated by cyclic and differential pulse voltammetric methods. Based on the influence of the potential scanning rate and solution pH on the voltammetric response of oxycodone oxidation, a redox mechanism was proposed. A 16 nM detection limit was acquired for the oxycodone analysis with a linear response in the 0.05-150 µM range. This sensor showed a remarkable ability for oxycodone detection in plasma samples. The long-term stability, superior selectivity, and reproducibility of this sensor prove its ability to measure oxycodone accurately and precisely in authentic spices.
Collapse
Affiliation(s)
- Masoumeh Ghalkhani
- Electrochemical Sensors Research Laboratory, Department of Chemistry, Faculty of Science, Shahid Rajaee Teacher Training University, Lavizan, P.O. Box 1678815811, Tehran, Iran.
| | - Esmail Sohouli
- Electrochemical Sensors Research Laboratory, Department of Chemistry, Faculty of Science, Shahid Rajaee Teacher Training University, Lavizan, P.O. Box 1678815811, Tehran, Iran
| | - Zeinab Saberi Dehkordi
- Department of Chemistry, Faculty of Science, Shahrekord Branch, Islamic Azad University, Shahrekord, Iran
| |
Collapse
|
2
|
Ansari S, Masoum S. A hybrid imprinted polymer based on magnetic graphene oxide and carbon dots for ultrasonic assisted dispersive solid-phase microextraction of oxycodone. Microchem J 2021. [DOI: 10.1016/j.microc.2021.105988] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
3
|
Khosropour H, Rezaei B, Alinajafi HA, Ensafi AA. Electrochemical sensor based on glassy carbon electrode modified by polymelamine formaldehyde/graphene oxide nanocomposite for ultrasensitive detection of oxycodone. Mikrochim Acta 2021; 188:1. [PMID: 33386503 DOI: 10.1007/s00604-020-04655-3] [Citation(s) in RCA: 77] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Accepted: 11/17/2020] [Indexed: 10/22/2022]
Abstract
Polymelamine formaldehyde/graphene oxide (PMF/GO) nanocomposite was used, for the first time, to study the ultrasensitive and selective electrochemical detection of oxycodone (OXC). The successful characterization of PMF/GO was verified based on scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared (FT-IR), X-ray diffraction (XRD), energy-dispersive spectroscopy (EDS), and Raman spectroscopy. The modified GCE (PMF/GO-GCE) proved its electrocatalytic effect on OXC determination according to cyclic, linear sweep, and differential pulse voltammetry (CV, LSV, and DPV) and electrochemical impedance spectroscopy (EIS) studies. The developed sensor under optimal conditions offered a linear relationship in a limited range of 0.01 to 45 μmol L-1 with the limit of detection (LOD) of 2.0 nmol L-1. The proposed PMF/GO-GCE sensor was effectively employed for the OXC detection in human urine and serum samples. Graphical abstract.
Collapse
Affiliation(s)
- Hossein Khosropour
- Department of Chemistry, Isfahan University of Technology, Isfahan, I.R., 84156-83111, Iran
| | - Behzad Rezaei
- Department of Chemistry, Isfahan University of Technology, Isfahan, I.R., 84156-83111, Iran.
| | - Hossein A Alinajafi
- Department of Chemistry, Isfahan University of Technology, Isfahan, I.R., 84156-83111, Iran
| | - Ali A Ensafi
- Department of Chemistry, Isfahan University of Technology, Isfahan, I.R., 84156-83111, Iran
| |
Collapse
|
4
|
Mynttinen E, Wester N, Lilius T, Kalso E, Mikladal B, Varjos I, Sainio S, Jiang H, Kauppinen EI, Koskinen J, Laurila T. Electrochemical Detection of Oxycodone and Its Main Metabolites with Nafion-Coated Single-Walled Carbon Nanotube Electrodes. Anal Chem 2020; 92:8218-8227. [PMID: 32412733 PMCID: PMC7735650 DOI: 10.1021/acs.analchem.0c00450] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
![]()
Oxycodone is a strong opioid
frequently used as an analgesic. Although proven efficacious in the
management of moderate to severe acute pain and cancer pain, use of
oxycodone imposes a risk of adverse effects such as addiction, overdose,
and death. Fast and accurate determination of oxycodone blood concentration
would enable personalized dosing and monitoring of the analgesic as
well as quick diagnostics of possible overdose in emergency care.
However, in addition to the parent drug, several metabolites are always
present in the blood after a dose of oxycodone, and to date, there
is no electrochemical data available on any of these metabolites.
In this paper, a single-walled carbon nanotube (SWCNT) electrode and
a Nafion-coated SWCNT electrode were used, for the first time, to
study the electrochemical behavior of oxycodone and its two main metabolites,
noroxycodone and oxymorphone. Both electrode types could selectively
detect oxycodone in the presence of noroxycodone and oxymorphone.
However, we have previously shown that addition of a Nafion coating
on top of the SWCNT electrode is essential for direct measurements
in complex biological matrices. Thus, the Nafion/SWCNT electrode was
further characterized and used for measuring clinically relevant concentrations
of oxycodone in buffer solution. The limit of detection for oxycodone
with the Nafion/SWCNT sensor was 85 nM, and the linear range was 0.5–10
μM in buffer solution. This study shows that the fabricated
Nafion/SWCNT sensor has potential to be applied in clinical concentration
measurements.
Collapse
Affiliation(s)
- Elsi Mynttinen
- Department of Electrical Engineering and Automation, Aalto University, Tietotie 3, 02150 Espoo, Finland
| | - Niklas Wester
- Department of Chemistry and Materials Science, Aalto University, Kemistintie 1, 02150 Espoo, Finland
| | - Tuomas Lilius
- Department of Pharmacology, University of Helsinki, Haartmaninkatu 8, 00290 Helsinki, Finland.,Department of Clinical Pharmacology, University of Helsinki and Helsinki University Hospital, Tukholmankatu 8C, 00290 Helsinki, Finland
| | - Eija Kalso
- Department of Pharmacology, University of Helsinki, Haartmaninkatu 8, 00290 Helsinki, Finland.,Pain Clinic, Department of Anesthesiology, Intensive Care and Pain Medicine, University of Helsinki and Helsinki University Hospital, Haartmaninkatu 2A, 00290 Helsinki, Finland
| | | | - Ilkka Varjos
- Canatu Oy, Tiilenlyöjänkuja 9, 01720 Vantaa, Finland
| | - Sami Sainio
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, California 94025, United States
| | - Hua Jiang
- Department of Applied Physics, Aalto University, 02150 Espoo, Finland
| | - Esko I Kauppinen
- Department of Applied Physics, Aalto University, 02150 Espoo, Finland
| | - Jari Koskinen
- Department of Chemistry and Materials Science, Aalto University, Kemistintie 1, 02150 Espoo, Finland
| | - Tomi Laurila
- Department of Electrical Engineering and Automation, Aalto University, Tietotie 3, 02150 Espoo, Finland
| |
Collapse
|
5
|
Fang WB, Lofwall MR, Walsh SL, Moody DE. Determination of oxycodone, noroxycodone and oxymorphone by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry in human matrices: in vivo and in vitro applications. J Anal Toxicol 2013; 37:337-44. [PMID: 23743505 DOI: 10.1093/jat/bkt042] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
The opioid analgesic oxycodone is widely abused and increasingly associated with overdose deaths. A sensitive analytical method was developed for oxycodone and its metabolites, noroxycodone and oxymorphone, in human plasma, urine (±enzymatic hydrolysis at 50°C for 16 h) and liver microsomes (HLMs). Liquid-liquid extraction was followed by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry. The calibration range was 0.2-250 ng/mL for plasma and HLM and 10-5000 ng/mL for urine. Intra- and interrun accuracies were within 13.3% of target; precisions were within 12.8% for all matrices. Recoveries from plasma were: oxycodone, 75.6%; noroxycodone, 37.4% and oxymorphone, 18.2%. Analytes exhibited room temperature stability in plasma and urine up to 24 h, and freeze-thaw stability in plasma up to three cycles. In 24-h hydrolyzed urine from subjects administered intranasal oxycodone (30 mg/70 kg, n = 5), mean concentrations (ng/mL) and % daily doses excreted were: oxycodone, 1150, 6.53%; noroxycodone, 1330, 7.81% and oxymorphone, 3000, 17.1%. Oxycodone incubated with HLM produced more noroxycodone than oxymorphone. With a panel of recombinant human cytochrome P450s (CYPs), CYP2C18 and CYP3A4 produced the most noroxycodone, whereas CYP2D6 produced the most oxymorphone. These results demonstrate a new method suitable for both in vivo and in vitro metabolism and pharmacokinetic studies of oxycodone.
Collapse
Affiliation(s)
- Wenfang B Fang
- 1Center for Human Toxicology, Department of Pharmacology and Toxicology, University of Utah, Salt Lake City, UT 84112, USA
| | | | | | | |
Collapse
|
6
|
Krishnamurthy RB, Upton RN, Fajumi AO, Lai S, Charlton CS, Ousley RM, Martinez AM, McConnell H, O'Connor SN, Ong J, Macintyre PE, Chapman MJ, Ludbrook GL. Pharmacokinetics of oxycodone after subcutaneous administration in a critically ill population compared with a healthy cohort. Anaesth Intensive Care 2012; 40:269-74. [PMID: 22417021 DOI: 10.1177/0310057x1204000209] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This study aimed to characterise and compare the absorption pharmacokinetics of a single subcutaneous dose of oxycodone in critically ill patients and healthy subjects. Blood samples taken at intervals from two minutes to eight hours after a subcutaneous dose of oxycodone in patients (5 mg) and healthy volunteers (10 mg) were assayed using high performance liquid chromatography. Data were analysed using a non-compartmental approach and presented as mean (SD). Parameters were corrected for dose differences between the groups assuming linear kinetics. Ten patients (eight male, two female) and seven healthy male subjects were included. Maximum venous concentration and area under the concentration curve were approximately two-fold lower in the patient group for an equivalent dose, suggesting either reduced bioavailability or increased clearance: maximum venous concentration 0.14 ± 0.06 vs 0.05 ± 0.02 µg/ml (P <0.0001); area under the concentration curve 19.50 ± 9.15 vs 9.72 ± 2.71 µg/ml/minute (P <0.001) respectively. However, time to maximum venous concentration and mean residence time were not different, suggesting similar absorption rates: time to maximum venous concentration 22.10 ± 18.0 vs 20.50 ± 16.10 minutes (P=0.81); mean residence time 353 ± 191 vs 291 ± 80 minutes (P=0.26). Kinetic parameters were less variable in patients than in volunteers. The patients therefore had reduced exposure to subcutaneous oxycodone. This warrants further model-based analysis and experimentation. Dose regimens for subcutaneous oxycodone developed in healthy volunteers cannot be directly translated to critically ill patients.
Collapse
Affiliation(s)
- R B Krishnamurthy
- Department of Intensive Care, Royal Adelaide Hospital, Adelaide, South Australia, Australia.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Sakurada T, Takada S, Eguchi H, Izumi K, Satoh N, Ueda S. Relationship between plasma concentrations of morphine and its metabolites and pain in cancer patients. ACTA ACUST UNITED AC 2010; 32:737-43. [DOI: 10.1007/s11096-010-9430-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2008] [Accepted: 08/09/2010] [Indexed: 11/29/2022]
|
8
|
Determination of Oxycodone, Noroxycodone, Oxymorphone, and Noroxymorphone in Human Plasma by Liquid Chromatography-Electrospray-Tandem Mass Spectrometry. Ther Drug Monit 2008; 30:333-40. [DOI: 10.1097/ftd.0b013e31816e2d4b] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
9
|
Musshoff F, Trafkowski J, Kuepper U, Madea B. An automated and fully validated LC-MS/MS procedure for the simultaneous determination of 11 opioids used in palliative care, with 5 of their metabolites. JOURNAL OF MASS SPECTROMETRY : JMS 2006; 41:633-40. [PMID: 16541404 DOI: 10.1002/jms.1021] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
A fully validated liquid chromatographic procedure coupled with electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) is presented for quantitative determination of the opioids buprenorphine, codeine, fentanyl, hydromorphone, methadone, morphine, oxycodone, oxymorphone, piritramide, tilidine, and tramadol together with their metabolites bisnortilidine, morphine-glucuronides, norfentanyl, and nortilidine in blood plasma after an automatically performed solid-phase extraction (SPE). Separation was achieved in 35 min on a Phenomenex C12 MAX-RP column (4 microm, 150 x 2 mm) using a gradient of ammonium formiate buffer (pH 3.5) and acetonitrile. The validation data were within the required limits. The assay was successfully applied to authentic plasma samples, allowing confirmation of the diagnosis of overdose situations as well as monitoring of patients' compliance, especially in patients under palliative care.
Collapse
Affiliation(s)
- F Musshoff
- Institute of Forensic Medicine, Stiftsplatz 12, 53111 Bonn, Germany.
| | | | | | | |
Collapse
|