1
|
Pilot Quality-Assurance Study of a Third-Generation Batch-Mode Clinical-Scale Automated Xenon-129 Hyperpolarizer. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27041327. [PMID: 35209116 PMCID: PMC8879294 DOI: 10.3390/molecules27041327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 02/08/2022] [Accepted: 02/10/2022] [Indexed: 11/28/2022]
Abstract
We present a pilot quality assurance (QA) study of a clinical-scale, automated, third-generation (GEN-3) 129Xe hyperpolarizer employing batch-mode spin-exchange optical pumping (SEOP) with high-Xe densities (50% natural abundance Xe and 50% N2 in ~2.6 atm total pressure sourced from Nova Gas Technologies) and rapid temperature ramping enabled by an aluminum heating jacket surrounding the 0.5 L SEOP cell. 129Xe hyperpolarization was performed over the course of 700 gas loading cycles of the SEOP cell, simulating long-term hyperpolarized contrast agent production in a clinical lung imaging setting. High levels of 129Xe polarization (avg. %PXe = 51.0% with standard deviation σPXe = 3.0%) were recorded with fast 129Xe polarization build-up time constants (avg. Tb = 25.1 min with standard deviation σTb = 3.1 min) across the first 500 SEOP cell refills, using moderate temperatures of 75 °C. These results demonstrate a more than 2-fold increase in build-up rate relative to previously demonstrated results in a comparable QA study on a second-generation (GEN-2) 129Xe hyperpolarizer device, with only a minor reduction in maximum achievable %PXe and with greater consistency over a larger number of SEOP cell refill processes at a similar polarization lifetime duration (avg. T1 = 82.4 min, standard deviation σT1 = 10.8 min). Additionally, the effects of varying SEOP jacket temperatures, distribution of Rb metal, and preparation and operation of the fluid path are quantified in the context of device installation, performance optimization and maintenance to consistently produce high 129Xe polarization values, build-up rates (Tb as low as 6 min) and lifetimes over the course of a typical high-throughput 129Xe polarization SEOP cell life cycle. The results presented further demonstrate the significant potential for hyperpolarized 129Xe contrast agent in imaging and bio-sensing applications on a clinical scale.
Collapse
|
2
|
Birchall JR, Irwin RK, Nikolaou P, Coffey AM, Kidd BE, Murphy M, Molway M, Bales LB, Ranta K, Barlow MJ, Goodson BM, Rosen MS, Chekmenev EY. XeUS: A second-generation automated open-source batch-mode clinical-scale hyperpolarizer. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 319:106813. [PMID: 32932118 DOI: 10.1016/j.jmr.2020.106813] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 08/20/2020] [Accepted: 08/24/2020] [Indexed: 06/11/2023]
Abstract
We present a second-generation open-source automated batch-mode 129Xe hyperpolarizer (XeUS GEN-2), designed for clinical-scale hyperpolarized (HP) 129Xe production via spin-exchange optical pumping (SEOP) in the regimes of high Xe density (0.66-2.5 atm partial pressure) and resonant photon flux (~170 W, Δλ = 0.154 nm FWHM), without the need for cryo-collection typically employed by continuous-flow hyperpolarizers. An Arduino micro-controller was used for hyperpolarizer operation. Processing open-source software was employed to program a custom graphical user interface (GUI), capable of remote automation. The Arduino Integrated Development Environment (IDE) was used to design a variety of customized automation sequences such as temperature ramping, NMR signal acquisition, and SEOP cell refilling for increased reliability. A polycarbonate 3D-printed oven equipped with a thermo-electric cooler/heater provides thermal stability for SEOP for both binary (Xe/N2) and ternary (4He-containing) SEOP cell gas mixtures. Quantitative studies of the 129Xe hyperpolarization process demonstrate that near-unity polarization can be achieved in a 0.5 L SEOP cell. For example, %PXe of 93.2 ± 2.9% is achieved at 0.66 atm Xe pressure with polarization build-up rate constant γSEOP = 0.040 ± 0.005 min-1, giving a max dose equivalent ≈ 0.11 L/h 100% hyperpolarized, 100% enriched 129Xe; %PXe of 72.6 ± 1.4% is achieved at 1.75 atm Xe pressure with γSEOP of 0.041 ± 0.001 min-1, yielding a corresponding max dose equivalent of 0.27 L/h. Quality assurance studies on this device have demonstrated the potential to refill SEOP cells hundreds of times without significant losses in performance, with average %PXe = 71.7%, (standard deviation σP = 1.52%) and mean polarization lifetime T1 = 90.5 min, (standard deviation σT = 10.3 min) over the first ~200 gas mixture refills, with sufficient performance maintained across a further ~700 refills. These findings highlight numerous technological developments and have significant translational relevance for efficient production of gaseous HP 129Xe contrast agents for use in clinical imaging and bio-sensing techniques.
Collapse
Affiliation(s)
- Jonathan R Birchall
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, MI 48202, United States
| | - Robert K Irwin
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham NG7 2RD, United Kingdom
| | | | - Aaron M Coffey
- Department of Radiology, Vanderbilt University Institute of Imaging Science (VUIIS), Nashville, TN 37232, United States
| | - Bryce E Kidd
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States
| | - Megan Murphy
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States
| | - Michael Molway
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States
| | - Liana B Bales
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States
| | - Kaili Ranta
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States
| | - Michael J Barlow
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham NG7 2RD, United Kingdom
| | - Boyd M Goodson
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States; Materials Technology Center, Southern Illinois University, Carbondale, IL 62901, United States
| | - Matthew S Rosen
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA 02129, United States; Department of Physics, Harvard University, Cambridge, MA 02138, United States
| | - Eduard Y Chekmenev
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, MI 48202, United States; Russian Academy of Sciences, Leninskiy Prospekt 14, Moscow 119991, Russia.
| |
Collapse
|
3
|
Birchall JR, Irwin RK, Nikolaou P, Pokochueva EV, Kovtunov KV, Koptyug IV, Barlow MJ, Goodson BM, Chekmenev EY. Pilot multi-site quality assurance study of batch-mode clinical-scale automated xenon-129 hyperpolarizers. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 316:106755. [PMID: 32512397 DOI: 10.1016/j.jmr.2020.106755] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 05/21/2020] [Accepted: 05/25/2020] [Indexed: 06/11/2023]
Abstract
We present a pilot quality assurance (QA) study of spin-exchange optical pumping (SEOP) performed on two nearly identical second-generation (GEN-2) automated batch-mode clinical-scale 129Xe hyperpolarizers, each utilizing a convective forced air oven, high-power (~170 W) continuous pump laser irradiation, and xenon-rich gas mixtures (~1.30 atm partial pressure). In one study, the repeatability of SEOP in a 1000 Torr Xe/900 Torr N2/100 Torr 4He (2000 Torr total pressure) gas mixture is evaluated over the course of ~700 gas loading cycles, with negligible decrease in performance during the first ~200 cycles, and with high 129Xe polarization levels (avg. %PXe = 71.7% with standard deviation σPXe = 1.5%), build-up rates (avg. γSEOP = 0.019 min-1 with standard deviation σγ = 0.003 min-1) and polarization lifetimes (avg. T1 = 90.5 min with standard deviation σT = 10.3 min) reported at moderate oven temperature of ~70 °C. Although the SEOP cell in this study exhibited a detectable performance decrease after 400 cycles, the cell continued to produce potentially useable HP 129Xe with %PXe = 42.3 ± 0.6% even after nearly 700 refill cycles. The possibility of "regenerating" "dormant" (i.e., not used for an extended period of time) SEOP cells using repeated temperature cycling methods to recover %PXe is also demonstrated. The quality and consistency of results show significant promise for translation to clinical-scale production of hyperpolarized 129Xe contrast agents for imaging and bio-sensing applications.
Collapse
Affiliation(s)
- Jonathan R Birchall
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, MI 48202, United States.
| | - Robert K Irwin
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham NG7 2RD, United Kingdom
| | | | - Ekaterina V Pokochueva
- International Tomography Center SB RAS, Institutskaya Street 3A, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova Street 2, Novosibirsk 630090, Russia
| | - Kirill V Kovtunov
- International Tomography Center SB RAS, Institutskaya Street 3A, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova Street 2, Novosibirsk 630090, Russia
| | - Igor V Koptyug
- International Tomography Center SB RAS, Institutskaya Street 3A, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova Street 2, Novosibirsk 630090, Russia
| | - Michael J Barlow
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham NG7 2RD, United Kingdom
| | - Boyd M Goodson
- Department of Chemistry and Biochemistry, Southern Illinois University, Carbondale, IL 62901, United States; Materials Technology Center, Southern Illinois University, Carbondale, IL 62901, United States
| | - Eduard Y Chekmenev
- Department of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), Detroit, MI 48202, United States; Russian Academy of Sciences, Leninskiy Prospekt 14, Moscow 119991, Russia.
| |
Collapse
|
4
|
Kuzmin VV, Nacher PJ. Signal feedback applications in low-field NMR and MRI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 310:106622. [PMID: 31765970 DOI: 10.1016/j.jmr.2019.106622] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 10/13/2019] [Accepted: 10/14/2019] [Indexed: 06/10/2023]
Abstract
Tuned pick-up coils with high quality factors Q are used in NMR and MRI for high-sensitivity and low-noise detection. However, large Q-factors introduce bandwidth issues at low frequency and the associated enhanced currents may cause significant radiation damping effects, especially with hyperpolarised samples. Signal feedback can be used to actively control these currents and adjust the detection bandwidth without resistive losses. Capacitive and inductive coupling methods are compared using detailed models and the operating conditions for efficient feedback with negligible noise penalty are discussed. Several high-impedance commercial preamplifiers have been found to affect the resonance characteristics of tuned coils in a gain-dependent way, or could not be used in low-frequency NMR because of oscillations at large positive gain. This is attributed to an undocumented internal feedback, and could be neutralised using external feedback. The implementation of an inductive coupling scheme to feed a suitably amplified phase-adjusted signal back into the PU coils of low-field NMR systems is described, and three experimental applications are reported. One system is used for NMR studies of distant dipolar field effects in highly polarised liquid 3He without or with radiation damping. The moderate intrinsic Q-factor (≈7) could be reduced (down to 1) or increased (up to 100) to control transient maser oscillations. Another system was used for MRI of water samples around 2 mT with Q≈190 litz-wire detection coils. The detection bandwidth was increased by actively reducing the Q-factor to obtain uniform sensitivities in images and avoid artifacts introduced by intensity corrections. Finally, parallel acquisition in MRI was performed using two separately tuned detection coils placed above and below the sample. They were actively decoupled using two feedback systems. For an imaging field of view smaller than the sample, artifact-free unfolded images demonstrate the efficiency of this active coil decoupling scheme.
Collapse
Affiliation(s)
- Vyacheslav V Kuzmin
- Laboratoire Kastler Brossel, ENS-Université PSL, CNRS, Sorbonne Université, Collège de France, 24 rue Lhomond, 75005 Paris, France.
| | - Pierre-Jean Nacher
- Laboratoire Kastler Brossel, ENS-Université PSL, CNRS, Sorbonne Université, Collège de France, 24 rue Lhomond, 75005 Paris, France.
| |
Collapse
|
5
|
Buckenmaier K, Rudolph M, Fehling P, Steffen T, Back C, Bernard R, Pohmann R, Bernarding J, Kleiner R, Koelle D, Plaumann M, Scheffler K. Mutual benefit achieved by combining ultralow-field magnetic resonance and hyperpolarizing techniques. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:125103. [PMID: 30599552 DOI: 10.1063/1.5043369] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Accepted: 11/08/2018] [Indexed: 06/09/2023]
Abstract
Ultralow-field (ULF) nuclear magnetic resonance spectroscopy (MRS) and magnetic resonance imaging (MRI) are promising spectroscopy and imaging methods allowing for, e.g., the simultaneous detection of multiple nuclei or imaging in the vicinity of metals. To overcome the inherently low signal-to-noise ratio that usually hampers a wider application, we present an alternative approach to prepolarized ULF MRS employing hyperpolarization techniques like signal amplification by reversible exchange (SABRE) or Overhauser dynamic nuclear polarization (ODNP). Both techniques allow continuous hyperpolarization of 1H as well as other MR-active nuclei. For the implementation, a superconducting quantum interference device (SQUID)-based ULF MRS/MRI detection scheme was constructed. Due to the very low intrinsic noise level, SQUIDs are superior to conventional Faraday detection coils at ULFs. Additionally, the broadband characteristics of SQUIDs enable them to simultaneously detect the MR signal of different nuclei such as 13C, 19F, or 1H. Since SQUIDs detect the MR signal directly, they are an ideal tool for a quantitative investigation of hyperpolarization techniques such as SABRE or ODNP.
Collapse
Affiliation(s)
- Kai Buckenmaier
- High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076 Tübingen, Germany
| | - Matthias Rudolph
- High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076 Tübingen, Germany
| | - Paul Fehling
- High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076 Tübingen, Germany
| | - Theodor Steffen
- High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076 Tübingen, Germany
| | - Christoph Back
- Physikalisches Institut and Center for Quantum Science (CQ) in LISA+, University of Tübingen, Tübingen, Germany
| | - Rebekka Bernard
- High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076 Tübingen, Germany
| | - Rolf Pohmann
- High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076 Tübingen, Germany
| | - Johannes Bernarding
- Department for Biometrics and Medical Informatics, Otto-von-Guericke University, Magdeburg, Germany
| | - Reinhold Kleiner
- Physikalisches Institut and Center for Quantum Science (CQ) in LISA+, University of Tübingen, Tübingen, Germany
| | - Dieter Koelle
- Physikalisches Institut and Center for Quantum Science (CQ) in LISA+, University of Tübingen, Tübingen, Germany
| | - Markus Plaumann
- Department for Biometrics and Medical Informatics, Otto-von-Guericke University, Magdeburg, Germany
| | - Klaus Scheffler
- High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076 Tübingen, Germany
| |
Collapse
|
6
|
Barskiy DA, Salnikov OG, Shchepin RV, Feldman MA, Coffey AM, Kovtunov KV, Koptyug IV, Chekmenev EY. NMR SLIC Sensing of Hydrogenation Reactions Using Parahydrogen in Low Magnetic Fields. THE JOURNAL OF PHYSICAL CHEMISTRY. C, NANOMATERIALS AND INTERFACES 2016; 120:29098-29106. [PMID: 28066517 PMCID: PMC5204359 DOI: 10.1021/acs.jpcc.6b07555] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2016] [Revised: 10/26/2016] [Indexed: 05/12/2023]
Abstract
Parahydrogen-induced polarization (PHIP) is an NMR hyperpolarization technique that increases nuclear spin polarization by orders of magnitude, and it is particularly well-suited to study hydrogenation reactions. However, the use of high-field NMR spectroscopy is not always possible, especially in the context of potential industrial-scale reactor applications. On the other hand, the direct low-field NMR detection of reaction products with enhanced nuclear spin polarization is challenging due to near complete signal cancellation from nascent parahydrogen protons. We show that hydrogenation products prepared by PHIP can be irradiated with weak (on the order of spin-spin couplings of a few hertz) alternating magnetic field (called Spin-Lock Induced Crossing or SLIC) and consequently efficiently detected at low magnetic field (e.g., 0.05 T used here) using examples of several types of organic molecules containing a vinyl moiety. The detected hyperpolarized signals from several reaction products at tens of millimolar concentrations were enhanced by 10000-fold, producing NMR signals an order of magnitude greater than the background signal from protonated solvents.
Collapse
Affiliation(s)
- Danila A. Barskiy
- Vanderbilt
University Institute of Imaging Sciences, Nashville, Tennessee 37232, United States
| | - Oleg G. Salnikov
- International
Tomography Center SB RAS, Novosibirsk 630090, Russia
- Novosibirsk
State University, Novosibirsk 630090, Russia
| | - Roman V. Shchepin
- Vanderbilt
University Institute of Imaging Sciences, Nashville, Tennessee 37232, United States
| | - Matthew A. Feldman
- Vanderbilt
University Institute of Imaging Sciences, Nashville, Tennessee 37232, United States
| | - Aaron M. Coffey
- Vanderbilt
University Institute of Imaging Sciences, Nashville, Tennessee 37232, United States
| | - Kirill V. Kovtunov
- International
Tomography Center SB RAS, Novosibirsk 630090, Russia
- Novosibirsk
State University, Novosibirsk 630090, Russia
| | - Igor V. Koptyug
- International
Tomography Center SB RAS, Novosibirsk 630090, Russia
- Novosibirsk
State University, Novosibirsk 630090, Russia
| | - Eduard Y. Chekmenev
- Vanderbilt
University Institute of Imaging Sciences, Nashville, Tennessee 37232, United States
- Russian
Academy of Sciences, Moscow 119991, Russia
| |
Collapse
|
7
|
Kovtunov KV, Truong ML, Barskiy D, Salnikov OG, Bukhtiyarov V, Coffey AM, Waddell KW, Koptyug IV, Chekmenev EY. Propane- d6 Heterogeneously Hyperpolarized by Parahydrogen. THE JOURNAL OF PHYSICAL CHEMISTRY. C, NANOMATERIALS AND INTERFACES 2014; 118:28234-28243. [PMID: 25506406 PMCID: PMC4259496 DOI: 10.1021/jp508719n] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2014] [Revised: 11/06/2014] [Indexed: 05/20/2023]
Abstract
Long-lived spin states of hyperpolarized propane-d6 gas were demonstrated following pairwise addition of parahydrogen gas to propene-d6 using heterogeneous parahydrogen-induced polarization (HET-PHIP). Hyperpolarized molecules were synthesized using Rh/TiO2 solid catalyst with 1.6 nm Rh nanoparticles. Hyperpolarized (PH ∼ 1%) propane-d6 was detected at high magnetic field (9.4 T) spectroscopically and by high-resolution 3D gradient-echo MRI (4.7 T) as the gas flowed through the radiofrequency coil with a spatial and temporal resolution of 0.5 × 0.5 × 0.5 mm3 and 17.7 s, respectively. Stopped-flow hyperpolarized propane-d6 gas was also detected at 0.0475 T with an observed nuclear spin polarization of PH ∼ 0.1% and a relatively long lifetime with T1,eff = 6.0 ± 0.3 s. Importantly, it was shown that the hyperpolarized protons of the deuterated product obtained via pairwise parahydrogen addition could be detected directly at low magnetic field. Importantly, the relatively long low-field T1,eff of HP propane-d6 gas is not susceptible to paramagnetic impurities as tested by exposure to ∼0.2 atm oxygen. This long lifetime and nontoxic nature of propane gas could be useful for bioimaging applications including potentially pulmonary low-field MRI. The feasibility of high-resolution low-field 2D gradient-echo MRI was demonstrated with 0.88 × 0.88 mm2 spatial and ∼0.7 s temporal resolution, respectively, at 0.0475 T.
Collapse
Affiliation(s)
- Kirill V. Kovtunov
- International
Tomography Center, 3A
Institutskaya St., Novosibirsk 630090, Russia
- Novosibirsk
State University, 2 Pirogova
St., Novosibirsk, 630090, Russia
- E-mail:
| | - Milton L. Truong
- Institute of Imaging Science, Department
of Radiology, Department of Biomedical
Engineering, Department of Physics and Astronomy, Department of Biochemistry, Vanderbilt-Ingram Cancer
Center, Vanderbilt University, Nashville, Tennessee 37232-2310, United States
| | - Danila
A. Barskiy
- International
Tomography Center, 3A
Institutskaya St., Novosibirsk 630090, Russia
- Novosibirsk
State University, 2 Pirogova
St., Novosibirsk, 630090, Russia
| | - Oleg G. Salnikov
- International
Tomography Center, 3A
Institutskaya St., Novosibirsk 630090, Russia
- Novosibirsk
State University, 2 Pirogova
St., Novosibirsk, 630090, Russia
| | - Valery
I. Bukhtiyarov
- Boreskov
Institute of Catalysis, SB RAS, 5 Acad. Lavrentiev Pr., Novosibirsk 630090, Russia
| | - Aaron M. Coffey
- Institute of Imaging Science, Department
of Radiology, Department of Biomedical
Engineering, Department of Physics and Astronomy, Department of Biochemistry, Vanderbilt-Ingram Cancer
Center, Vanderbilt University, Nashville, Tennessee 37232-2310, United States
| | - Kevin W. Waddell
- Institute of Imaging Science, Department
of Radiology, Department of Biomedical
Engineering, Department of Physics and Astronomy, Department of Biochemistry, Vanderbilt-Ingram Cancer
Center, Vanderbilt University, Nashville, Tennessee 37232-2310, United States
| | - Igor V. Koptyug
- International
Tomography Center, 3A
Institutskaya St., Novosibirsk 630090, Russia
- Novosibirsk
State University, 2 Pirogova
St., Novosibirsk, 630090, Russia
| | - Eduard Y. Chekmenev
- Institute of Imaging Science, Department
of Radiology, Department of Biomedical
Engineering, Department of Physics and Astronomy, Department of Biochemistry, Vanderbilt-Ingram Cancer
Center, Vanderbilt University, Nashville, Tennessee 37232-2310, United States
- E-mail:
| |
Collapse
|
8
|
Zheng Y, Cates GD, Tobias WA, Mugler JP, Miller GW. Very-low-field MRI of laser polarized xenon-129. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2014; 249:108-117. [PMID: 25462954 DOI: 10.1016/j.jmr.2014.09.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2014] [Revised: 09/29/2014] [Accepted: 09/29/2014] [Indexed: 06/04/2023]
Abstract
We describe a homebuilt MRI system for imaging laser-polarized xenon-129 at a very low holding field of 2.2mT. A unique feature of this system was the use of Maxwell coils oriented at so-called "magic angles" to generate the transverse magnetic field gradients, which provided a simple alternative to Golay coils. We used this system to image a laser-polarized xenon-129 phantom with both a conventional gradient-echo and a fully phase-encoded pulse sequence. In other contexts, a fully phase-encoded acquisition, also known as single-point or constant-time imaging, has been used to enable distortion-free imaging of short-T2∗ species. Here we used this technique to overcome imperfections associated with our homebuilt MRI system while also taking full advantage of the long T2∗ available at very low field. Our results demonstrate that xenon-129 image quality can be dramatically improved at low field by combining a fully phase-encoded k-space acquisition with auxiliary measurements of system imperfections including B0 field drift and gradient infidelity.
Collapse
Affiliation(s)
- Yuan Zheng
- Department of Physics, University of Virginia, Charlottesville, VA 22904, USA
| | - Gordon D Cates
- Department of Physics, University of Virginia, Charlottesville, VA 22904, USA; Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA 22908, USA
| | - William A Tobias
- Department of Physics, University of Virginia, Charlottesville, VA 22904, USA
| | - John P Mugler
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA 22908, USA
| | - G Wilson Miller
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA 22908, USA.
| |
Collapse
|
9
|
Barskiy DA, Kovtunov KV, Koptyug IV, He P, Groome KA, Best QA, Shi F, Goodson BM, Shchepin RV, Truong ML, Coffey AM, Waddell KW, Chekmenev EY. In situ and ex situ low-field NMR spectroscopy and MRI endowed by SABRE hyperpolarization. Chemphyschem 2014; 15:4100-7. [PMID: 25367202 DOI: 10.1002/cphc.201402607] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2014] [Revised: 09/26/2014] [Indexed: 12/11/2022]
Abstract
By using 5.75 and 47.5 mT nuclear magnetic resonance (NMR) spectroscopy, up to 10(5)-fold sensitivity enhancement through signal amplification by reversible exchange (SABRE) was enabled, and subsecond temporal resolution was used to monitor an exchange reaction that resulted in the buildup and decay of hyperpolarized species after parahydrogen bubbling. We demonstrated the high-resolution low-field proton magnetic resonance imaging (MRI) of pyridine in a 47.5 mT magnetic field endowed by SABRE. Molecular imaging (i.e. imaging of dilute hyperpolarized substances rather than the bulk medium) was conducted in two regimes: in situ real-time MRI of the reaction mixture (in which pyridine was hyperpolarized), and ex situ MRI (in which hyperpolarization decays) of the liquid hyperpolarized product. Low-field (milli-Tesla range, e.g. 5.75 and 47.5 mT used in this study) parahydrogen-enhanced NMR and MRI, which are free from the limitations of high-field magnetic resonance (including susceptibility-induced gradients of the static magnetic field at phase interfaces), potentially enables new imaging applications as well as differentiation of hyperpolarized chemical species on demand by exploiting spin manipulations with static and alternating magnetic fields.
Collapse
Affiliation(s)
- Danila A Barskiy
- Laboratory of Magnetic Resonance Microimaging, International Tomography Center, SB RAS, 3 A Institutskaya St. Novosibirsk 630090 (Russia); Novosibirsk State University, 2 Pirogova St. Novosibirsk 630090 (Russia)
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Coffey AM, Kovtunov KV, Barskiy DA, Koptyug IV, Shchepin RV, Waddell KW, He P, Groome KA, Best QA, Shi F, Goodson BM, Chekmenev EY. High-resolution low-field molecular magnetic resonance imaging of hyperpolarized liquids. Anal Chem 2014; 86:9042-9. [PMID: 25162371 PMCID: PMC4165454 DOI: 10.1021/ac501638p] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
We demonstrate the feasibility of microscale molecular imaging using hyperpolarized proton and carbon-13 MRI contrast media and low-field (47.5 mT) preclinical scale (38 mm i.d.) 2D magnetic resonance imaging (MRI). Hyperpolarized proton images with 94 × 94 μm(2) spatial resolution and hyperpolarized carbon-13 images with 250 × 250 μm(2) in-plane spatial resolution were recorded in 4-8 s (largely limited by the electronics response), surpassing the in-plane spatial resolution (i.e., pixel size) achievable with micro-positron emission tomography (PET). These hyperpolarized proton and (13)C images were recorded using large imaging matrices of up to 256 × 256 pixels and relatively large fields of view of up to 6.4 × 6.4 cm(2). (13)C images were recorded using hyperpolarized 1-(13)C-succinate-d2 (30 mM in water, %P(13C) = 25.8 ± 5.1% (when produced) and %P(13C) = 14.2 ± 0.7% (when imaged), T1 = 74 ± 3 s), and proton images were recorded using (1)H hyperpolarized pyridine (100 mM in methanol-d4, %P(H) = 0.1 ± 0.02% (when imaged), T1 = 11 ± 0.1 s). Both contrast agents were hyperpolarized using parahydrogen (>90% para-fraction) in an automated 5.75 mT parahydrogen induced polarization (PHIP) hyperpolarizer. A magnetized path was demonstrated for successful transportation of a (13)C hyperpolarized contrast agent (1-(13)C-succinate-d2, sensitive to fast depolarization when at the Earth's magnetic field) from the PHIP polarizer to the 47.5 mT low-field MRI. While future polarizing and low-field MRI hardware and imaging sequence developments can further improve the low-field detection sensitivity, the current results demonstrate that microscale molecular imaging in vivo is already feasible at low (<50 mT) fields and potentially at low (~1 mM) metabolite concentrations.
Collapse
Affiliation(s)
- Aaron M Coffey
- Vanderbilt University Institute of Imaging Science (VUIIS) and Department of Radiology, Vanderbilt University , Nashville, Tennessee 37232, United States
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Nikolaou P, Coffey AM, Barlow MJ, Rosen MS, Goodson BM, Chekmenev EY. Temperature-ramped (129)Xe spin-exchange optical pumping. Anal Chem 2014; 86:8206-12. [PMID: 25008290 PMCID: PMC4139178 DOI: 10.1021/ac501537w] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2014] [Accepted: 06/26/2014] [Indexed: 12/12/2022]
Abstract
We describe temperature-ramped spin-exchange optical pumping (TR-SEOP) in an automated high-throughput batch-mode (129)Xe hyperpolarizer utilizing three key temperature regimes: (i) "hot"-where the (129)Xe hyperpolarization rate is maximal, (ii) "warm"-where the (129)Xe hyperpolarization approaches unity, and (iii) "cool"-where hyperpolarized (129)Xe gas is transferred into a Tedlar bag with low Rb content (<5 ng per ∼1 L dose) suitable for human imaging applications. Unlike with the conventional approach of batch-mode SEOP, here all three temperature regimes may be operated under continuous high-power (170 W) laser irradiation, and hyperpolarized (129)Xe gas is delivered without the need for a cryocollection step. The variable-temperature approach increased the SEOP rate by more than 2-fold compared to the constant-temperature polarization rate (e.g., giving effective values for the exponential buildup constant γSEOP of 62.5 ± 3.7 × 10(-3) min(-1) vs 29.9 ± 1.2 × 10(-3) min(-1)) while achieving nearly the same maximum %PXe value (88.0 ± 0.8% vs 90.1% ± 0.8%, for a 500 Torr (67 kPa) Xe cell loading-corresponding to nuclear magnetic resonance/magnetic resonance imaging (NMR/MRI) enhancements of ∼3.1 × 10(5) and ∼2.32 × 10(8) at the relevant fields for clinical imaging and HP (129)Xe production of 3 T and 4 mT, respectively); moreover, the intercycle "dead" time was also significantly decreased. The higher-throughput TR-SEOP approach can be implemented without sacrificing the level of (129)Xe hyperpolarization or the experimental stability for automation-making this approach beneficial for improving the overall (129)Xe production rate in clinical settings.
Collapse
Affiliation(s)
- Panayiotis Nikolaou
- Department
of Radiology, Vanderbilt University Institute of Imaging
Science, Vanderbilt University, Nashville, Tennessee 37232, United States
| | - Aaron M. Coffey
- Department
of Radiology, Vanderbilt University Institute of Imaging
Science, Vanderbilt University, Nashville, Tennessee 37232, United States
- Department of Biomedical
Engineering, Department of Biochemistry, and Vanderbilt-Ingram
Cancer Center, Vanderbilt University, Nashville, Tennessee 37205, United States
| | - Michael J. Barlow
- Sir Peter Mansfield
Magnetic Resonance Centre, University of Nottingham, Nottingham, NG7 2RD, United Kingdom
| | - Matthew S. Rosen
- Athinoula A. Martinos
Center for Biomedical Imaging, Massachusetts General
Hospital, Boston, Massachusetts 02129, United States
- Department
of Physics, Harvard University, Cambridge, Massachusetts 02138, United States
| | - Boyd M. Goodson
- Department
of Chemistry and Biochemistry, Southern
Illinois University, Carbondale, Illinois 62901, United States
| | - Eduard Y. Chekmenev
- Department
of Radiology, Vanderbilt University Institute of Imaging
Science, Vanderbilt University, Nashville, Tennessee 37232, United States
- Department of Biomedical
Engineering, Department of Biochemistry, and Vanderbilt-Ingram
Cancer Center, Vanderbilt University, Nashville, Tennessee 37205, United States
| |
Collapse
|
12
|
Kędzia P, Czechowski T, Baranowski M, Jurga J, Szcześniak E. Analysis of Uniformity of Magnetic Field Generated by the Two-Pair Coil System. APPLIED MAGNETIC RESONANCE 2013; 44:605-618. [PMID: 23761951 PMCID: PMC3677240 DOI: 10.1007/s00723-012-0427-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/08/2012] [Revised: 10/22/2012] [Indexed: 06/02/2023]
Abstract
In this paper we use a simple analysis based on properties of the axial field generated by symmetrical multipoles to reveal all possible distributions of two coaxial pairs of circular windings, which result in systems featuring zero octupole and 32 pole magnetic moments (six-order systems). Homogeneity of magnetic field of selected systems is analyzed. It has been found that one of the derived systems generates homogenous magnetic field whose volume is comparable to that yielded by the eight-order system. The influence of the current distribution and the windings placement on the field homogeneity is considered. The table, graphs and equations given in the paper facilitate the choice of the most appropriate design for a given problem. The systems presented may find applications in low field electron paramagnetic resonance imaging, some functional f-MRI (nuclear magnetic resonance imaging) and bioelectromagnetic experiments requiring the access to the working space from all directions.
Collapse
Affiliation(s)
- P. Kędzia
- Laboratory of EPR Tomography Institute of Materials Technology, Faculty of Mechanical Engineering and Management, Poznan University of Technology, Piotrowo 3 St., 60-965 Poznan, Poland
| | - T. Czechowski
- Laboratory of EPR Tomography Institute of Materials Technology, Faculty of Mechanical Engineering and Management, Poznan University of Technology, Piotrowo 3 St., 60-965 Poznan, Poland
| | - M. Baranowski
- Laboratory of EPR Tomography Institute of Materials Technology, Faculty of Mechanical Engineering and Management, Poznan University of Technology, Piotrowo 3 St., 60-965 Poznan, Poland
- Department of Physics, Adam Mickiewicz University, Umultowska 85, St., 61-614 Poznan, Poland
| | - J. Jurga
- Laboratory of EPR Tomography Institute of Materials Technology, Faculty of Mechanical Engineering and Management, Poznan University of Technology, Piotrowo 3 St., 60-965 Poznan, Poland
| | - E. Szcześniak
- Laboratory of EPR Tomography Institute of Materials Technology, Faculty of Mechanical Engineering and Management, Poznan University of Technology, Piotrowo 3 St., 60-965 Poznan, Poland
| |
Collapse
|
13
|
Lisitza N, Muradian I, Frederick E, Patz S, Hatabu H, Chekmenev EY. Toward 13C hyperpolarized biomarkers produced by thermal mixing with hyperpolarized 129Xe. J Chem Phys 2009; 131:044508. [PMID: 19655895 PMCID: PMC2730707 DOI: 10.1063/1.3181062] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2009] [Accepted: 06/23/2009] [Indexed: 11/15/2022] Open
Abstract
The (13)C NMR signal of acetic acid 1-(13)C-AcH is enhanced by polarization transfer from hyperpolarized (129)Xe using a thermal mixing procedure. 1-(13)C-AcH acid and hyperpolarized (129)Xe are mixed as gases to disperse (129)Xe in the acetic acid. The mixture is frozen with liquid N(2) at 0.5 T. The magnetic field is then momentarily dropped to allow for exchange of spin polarization between (13)C and (129)Xe. After polarization exchange the magnetic field is raised to its original value and the mixture is thawed, resulting in a solution of polarization enhanced 1-(13)C-AcH. A (13)C nuclear spin polarization enhancement of 10 is observed compared to its thermal polarization at 4.7 T. This polarization enhancement is approximately three orders of magnitude lower than that predicted by theory. The discrepancy is attributed to the formation of either an inhomogeneous solid matrix and/or spin dynamics during polarization transfer. Despite the low polarization enhancement, this is the first report of polarization transfer from (129)Xe to (13)C nuclear spins achieved by thermal mixing for a proton-containing molecule of biomedical importance. If future work can increase the enhancement, this method will be useful in hyperpolarizing a wide range of (13)C enriched compounds important in biomedical and biophysical research.
Collapse
Affiliation(s)
- Natalia Lisitza
- Enhanced Magnetic Resonance Laboratory, Huntington Medical Research Institutes, Pasadena, California 91105, USA.
| | | | | | | | | | | |
Collapse
|
14
|
Tsai LL, Mair RW, Rosen MS, Patz S, Walsworth RL. An open-access, very-low-field MRI system for posture-dependent 3He human lung imaging. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2008; 193:274-85. [PMID: 18550402 PMCID: PMC2572034 DOI: 10.1016/j.jmr.2008.05.016] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2007] [Revised: 05/14/2008] [Accepted: 05/14/2008] [Indexed: 05/20/2023]
Abstract
We describe the design and operation of an open-access, very-low-field, magnetic resonance imaging (MRI) system for in vivo hyperpolarized 3He imaging of the human lungs. This system permits the study of lung function in both horizontal and upright postures, a capability with important implications in pulmonary physiology and clinical medicine, including asthma and obesity. The imager uses a bi-planar B(0) coil design that produces an optimized 65 G (6.5 mT) magnetic field for 3He MRI at 210 kHz. Three sets of bi-planar coils produce the x, y, and z magnetic field gradients while providing a 79-cm inter-coil gap for the imaging subject. We use solenoidal Q-spoiled RF coils for operation at low frequencies, and are able to exploit insignificant sample loading to allow for pre-tuning/matching schemes and for accurate pre-calibration of flip angles. We obtain sufficient SNR to acquire 2D 3He images with up to 2.8mm resolution, and present initial 2D and 3D 3He images of human lungs in both supine and upright orientations. 1H MRI can also be performed for diagnostic and calibration reasons.
Collapse
Affiliation(s)
- L. L. Tsai
- Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA 02139
- Harvard Medical School, Boston, MA 02115
| | - R. W. Mair
- Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138
| | - M. S. Rosen
- Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138
- Department of Physics, Harvard University, Cambridge, MA 02138
| | - S. Patz
- Harvard Medical School, Boston, MA 02115
- Department of Radiology, Brigham and Women’s Hospital, Boston, MA 02115
| | - R. L. Walsworth
- Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138
- Department of Physics, Harvard University, Cambridge, MA 02138
| |
Collapse
|
15
|
Tsai LL, Mair RW, Li CH, Rosen MS, Patz S, Walsworth RL. Posture-dependent human 3He lung imaging in an open-access MRI system: initial results. Acad Radiol 2008; 15:728-39. [PMID: 18486009 PMCID: PMC2474800 DOI: 10.1016/j.acra.2007.10.010] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2007] [Revised: 09/24/2007] [Accepted: 10/17/2007] [Indexed: 11/28/2022]
Abstract
RATIONALE AND OBJECTIVES The human lung and its functions are extremely sensitive to orientation and posture, and debate continues as to the role of gravity and the surrounding anatomy in determining lung function and heterogeneity of perfusion and ventilation. However, study of these effects is difficult. The conventional high-field magnets used for most hyperpolarized (3)He magnetic resonance imaging (MRI) of the human lung, and most other common radiologic imaging modalities including positron emission tomography and computed tomography, restrict subjects to lying horizontally, minimizing most gravitational effects. MATERIALS AND METHODS In this article, we review the motivation for posture-dependent studies of human lung function and present initial imaging results of human lungs in the supine and vertical body orientations using inhaled hyperpolarized (3)He gas and an open-access MRI instrument. The open geometry of this MRI system features a "walk-in" capability that permits subjects to be imaged in vertical and horizontal positions and potentially allows for complete rotation of the orientation of the imaging subject in a two-dimensional plane. RESULTS Initial results include two-dimensional lung images acquired with approximately 4 x 8 mm in-plane resolution and three-dimensional images with approximately 2-cm slice thickness. CONCLUSIONS Effects of posture variation are observed, including posture-related effects of the diaphragm and distension of the lungs while vertical.
Collapse
Affiliation(s)
- Leo L Tsai
- Harvard-Smithsonian Center for Astrophysics, 60 Garden St, MS 59, Cambridge, MA 02138, USA
| | | | | | | | | | | |
Collapse
|