1
|
Abstract
Mass cytometry has revolutionized immunophenotyping, particularly in exploratory settings where simultaneous breadth and depth of characterization of immune populations is needed with limited samples such as in preclinical and clinical tumor immunotherapy. Mass cytometry is also a powerful tool for single-cell immunological assays, especially for complex and simultaneous characterization of diverse intratumoral immune subsets or immunotherapeutic cell populations. Through the elimination of spectral overlap seen in optical flow cytometry by replacement of fluorescent labels with metal isotopes, mass cytometry allows, on average, robust analysis of 60 individual parameters simultaneously. This is, however, associated with significantly increased complexity in the design, execution, and interpretation of mass cytometry experiments. To address the key pitfalls associated with the fragmentation, complexity, and analysis of data in mass cytometry for immunologists who are novices to these techniques, we have developed a comprehensive resource guide. Included in this review are experiment and panel design, antibody conjugations, sample staining, sample acquisition, and data pre-processing and analysis. Where feasible multiple resources for the same process are compared, allowing researchers experienced in flow cytometry but with minimal mass cytometry expertise to develop a data-driven and streamlined project workflow. It is our hope that this manuscript will prove a useful resource for both beginning and advanced users of mass cytometry.
Collapse
Affiliation(s)
- Akshay Iyer
- Department of Pediatrics, University of Miami Miller School of Medicine, Miami, FL, United States
- Department of Microbiology and Immunology, University of Miami Miller School of Medicine, Miami, FL, United States
| | - Anouk A. J. Hamers
- Department of Pediatrics, University of Miami Miller School of Medicine, Miami, FL, United States
- Department of Microbiology and Immunology, University of Miami Miller School of Medicine, Miami, FL, United States
- Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL, United States
| | - Asha B. Pillai
- Department of Pediatrics, University of Miami Miller School of Medicine, Miami, FL, United States
- Department of Microbiology and Immunology, University of Miami Miller School of Medicine, Miami, FL, United States
- Sylvester Comprehensive Cancer Center, University of Miami Miller School of Medicine, Miami, FL, United States
- Sheila and David Fuente Program in Cancer Biology, University of Miami Miller School of Medicine, Miami, FL, United States
| |
Collapse
|
2
|
Soh KT, Came N, Otteson GE, Jevremovic D, Shi M, Olteanu H, Natoni A, Lagoo A, Theakston E, Óskarsson JÞ, Gorniak M, Grigoriadis G, Arroz M, Fletcher M, Lin P, Ludwig P, Tembhare P, Matuzeviciene R, Radzevicius M, Kay S, Chen W, Cabrita C, Wallace PK. Evaluation of multiple myeloma measurable residual disease by high sensitivity flow cytometry: An international harmonized approach for data analysis. CYTOMETRY PART B: CLINICAL CYTOMETRY 2022; 102:88-106. [PMID: 35005838 PMCID: PMC10105368 DOI: 10.1002/cyto.b.22053] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 11/15/2021] [Accepted: 12/21/2021] [Indexed: 01/02/2023]
Abstract
BACKGROUND Multiple myeloma (MM) measurable residual disease (MRD) evaluated by flow cytometry is a surrogate for progression-free and overall survival in clinical trials. However, analysis and reporting between centers lack uniformity. We designed and evaluated a consensus protocol for MM MRD analysis to reduce inter-laboratory variation in MM MRD reporting. METHODS Seventeen participants from 13 countries performed blinded analysis of the same eight de-identified flow cytometry files from patients with/without MRD using their own method (Stage 1). A consensus gating protocol was then designed following survey and discussions, and the data re-analyzed for MRD and other bone marrow cells (Stage 2). Inter-laboratory variation using the consensus strategy was reassessed for another 10 cases and compared with earlier results (Stage 3). RESULTS In Stage 1, participants agreed on MRD+/MRD- status 89% and 68% of the time respectively. Inter-observer variation was high for total numbers of analyzed cells, total and normal plasma cells (PCs), limit of detection, lower limit of quantification, and enumeration of cell populations that determine sample adequacy. The identification of abnormal PCs remained relatively consistent. By consensus method, average agreement on MRD- status improved to 74%. Better consistency enumerating all parameters among operators resulted in near-unanimous agreement on sample adequacy. CONCLUSION Uniform flow cytometry data analysis substantially reduced inter-laboratory variation in reporting multiple components of the MM MRD assay. Adoption of a harmonized approach would meet an important need for conformity in reporting MM MRD for clinical trials, and wider acceptance of MM MRD as a surrogate clinical endpoint.
Collapse
Affiliation(s)
- Kah Teong Soh
- Roswell Park Comprehensive Cancer Center Buffalo New York USA
| | - Neil Came
- Peter MacCallum Cancer Centre Melbourne Victoria Australia
| | | | | | - Min Shi
- Mayo Clinic Rochester Minnesota USA
| | | | | | - Anand Lagoo
- Duke University Medical Center Durham North Carolina USA
| | | | | | | | | | - Maria Arroz
- Centro Hospitalar de Lisboa Ocidental Hospital S. Francisco Xavier Lisbon Portugal
| | - Matthew Fletcher
- UK NEQAS for Leucocyte Immunophenotyping, Department of Haematology Royal Hallamshire Hospital Sheffield UK
| | - Pei Lin
- MD Anderson Cancer Center Houston Texas USA
| | | | | | - Reda Matuzeviciene
- Institute of Biomedical Sciences, Department of Physiology, Biochemistry, Microbiology and Laboratory Medicine, Faculty of Medicine Vilnius University Vilnius Lithuania
- Laboratory Medicine Centre Vilnius University Hospital Santaros Clinics Vilnius Lithuania
| | - Mantas Radzevicius
- Institute of Biomedical Sciences, Department of Physiology, Biochemistry, Microbiology and Laboratory Medicine, Faculty of Medicine Vilnius University Vilnius Lithuania
- Laboratory Medicine Centre Vilnius University Hospital Santaros Clinics Vilnius Lithuania
| | - Sigi Kay
- Tel‐Aviv Sourasky Medical Center Tel‐Aviv Israel
| | - Weina Chen
- University of Texas Southwestern Medical Center Dallas Texas USA
| | | | - Paul K. Wallace
- Roswell Park Comprehensive Cancer Center Buffalo New York USA
| |
Collapse
|
3
|
Bravo-Pérez C, Sola M, Teruel-Montoya R, García-Malo MD, Ortuño FJ, Vicente V, de Arriba F, Jerez A. Minimal Residual Disease in Multiple Myeloma: Something Old, Something New. Cancers (Basel) 2021; 13:4332. [PMID: 34503142 PMCID: PMC8430644 DOI: 10.3390/cancers13174332] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2021] [Revised: 08/20/2021] [Accepted: 08/23/2021] [Indexed: 12/13/2022] Open
Abstract
The game-changing outcome effect, due to the generalized use of novel agents in MM, has cre-ated a paradigm shift. Achieving frequent deep responses has placed MM among those neoplasms where the rationale for assessing MRD is fulfilled. However, its implementation in MM has raised specific questions: how might we weight standard measures against deep MRD in the emerging CAR-T setting? Which high sensitivity method to choose? Are current response criteria still useful? In this work, we address lessons learned from the use of MRD in other neoplasms, the steps followed for the harmonization of current methods for comprehensively measuring MRD, and the challenges that new therapies and concepts pose in the MM clinical field.
Collapse
Affiliation(s)
- Carlos Bravo-Pérez
- Hematology and Medical Oncology Department, University Hospital Morales Meseguer, IMIB, 30003 Murcia, Spain; (C.B.-P.); (M.S.); (M.D.G.-M.); (F.J.O.); (V.V.); (F.d.A.); (A.J.)
| | - María Sola
- Hematology and Medical Oncology Department, University Hospital Morales Meseguer, IMIB, 30003 Murcia, Spain; (C.B.-P.); (M.S.); (M.D.G.-M.); (F.J.O.); (V.V.); (F.d.A.); (A.J.)
| | - Raúl Teruel-Montoya
- Hematology and Medical Oncology Department, University Hospital Morales Meseguer, IMIB, 30003 Murcia, Spain; (C.B.-P.); (M.S.); (M.D.G.-M.); (F.J.O.); (V.V.); (F.d.A.); (A.J.)
- CB15/00055-CIBERER, 30003 Murcia, Spain
| | - María Dolores García-Malo
- Hematology and Medical Oncology Department, University Hospital Morales Meseguer, IMIB, 30003 Murcia, Spain; (C.B.-P.); (M.S.); (M.D.G.-M.); (F.J.O.); (V.V.); (F.d.A.); (A.J.)
| | - Francisco José Ortuño
- Hematology and Medical Oncology Department, University Hospital Morales Meseguer, IMIB, 30003 Murcia, Spain; (C.B.-P.); (M.S.); (M.D.G.-M.); (F.J.O.); (V.V.); (F.d.A.); (A.J.)
| | - Vicente Vicente
- Hematology and Medical Oncology Department, University Hospital Morales Meseguer, IMIB, 30003 Murcia, Spain; (C.B.-P.); (M.S.); (M.D.G.-M.); (F.J.O.); (V.V.); (F.d.A.); (A.J.)
- CB15/00055-CIBERER, 30003 Murcia, Spain
| | - Felipe de Arriba
- Hematology and Medical Oncology Department, University Hospital Morales Meseguer, IMIB, 30003 Murcia, Spain; (C.B.-P.); (M.S.); (M.D.G.-M.); (F.J.O.); (V.V.); (F.d.A.); (A.J.)
| | - Andrés Jerez
- Hematology and Medical Oncology Department, University Hospital Morales Meseguer, IMIB, 30003 Murcia, Spain; (C.B.-P.); (M.S.); (M.D.G.-M.); (F.J.O.); (V.V.); (F.d.A.); (A.J.)
- CB15/00055-CIBERER, 30003 Murcia, Spain
| |
Collapse
|
4
|
Maclachlan KH, Came N, Diamond B, Roshal M, Ho C, Thoren K, Mayerhoefer ME, Landgren O, Harrison S. Minimal residual disease in multiple myeloma: defining the role of next generation sequencing and flow cytometry in routine diagnostic use. Pathology 2021; 53:385-399. [PMID: 33674146 DOI: 10.1016/j.pathol.2021.02.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2020] [Revised: 02/01/2021] [Accepted: 02/03/2021] [Indexed: 12/11/2022]
Abstract
For patients diagnosed with multiple myeloma (MM) there have been significant treatment advances over the past decade, reflected in an increasing proportion of patients achieving durable remissions. Clinical trials repeatedly demonstrate that achieving a deep response to therapy, with a bone marrow assessment proving negative for minimal residual disease (MRD), confers a significant survival advantage. To accurately assess for minute quantities of residual cancer requires highly sensitive methods; either multiparameter flow cytometry or next generation sequencing are currently recommended for MM response assessment. Under optimal conditions, these methods can detect one aberrant cell amongst 1,000,000 normal cells (a sensitivity of 10-6). Here, we will review the practical use of MRD assays in MM, including challenges in implementation for the routine diagnostic laboratory, standardisation across laboratories and clinical trials, the clinical integration of MRD status assessment into MM management and future directions for ongoing research.
Collapse
Affiliation(s)
- Kylee H Maclachlan
- Myeloma Service, Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA; Haematology Service, Peter MacCallum Cancer Centre, East Melbourne, Vic, Australia; Sir Peter MacCallum Department of Oncology, University of Melbourne, Parkville, Vic, Australia.
| | - Neil Came
- Sir Peter MacCallum Department of Oncology, University of Melbourne, Parkville, Vic, Australia; Pathology Department, Peter MacCallum Cancer Centre, East Melbourne, Vic, Australia
| | - Benjamin Diamond
- Myeloma Service, Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Mikhail Roshal
- Department of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Caleb Ho
- Department of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Katie Thoren
- Department of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Marius E Mayerhoefer
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Ola Landgren
- Myeloma Service, Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA; Myeloma Program, Department of Medicine, Sylvester Comprehensive Cancer Center, University of Miami, Miami, FL, USA
| | - Simon Harrison
- Haematology Service, Peter MacCallum Cancer Centre, East Melbourne, Vic, Australia; Sir Peter MacCallum Department of Oncology, University of Melbourne, Parkville, Vic, Australia
| |
Collapse
|
5
|
Bayly E, Nguyen V, Binek A, Piggin A, Baldwin K, Westerman D, Came N. Validation of a modified pre-lysis sample preparation technique for flow cytometric minimal residual disease assessment in multiple myeloma, chronic lymphocytic leukemia, and B-non Hodgkin lymphoma. CYTOMETRY PART B-CLINICAL CYTOMETRY 2020; 98:385-398. [PMID: 32530574 DOI: 10.1002/cyto.b.21893] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 05/11/2020] [Accepted: 05/13/2020] [Indexed: 12/13/2022]
Abstract
BACKGROUND Minimal residual disease (MRD) assessment of hematopoietic neoplasia below 10-4 requires more leukocytes than is usually attainable by post-lysis preparation. However, not all laboratories are resourced for consensus Euroflow pre-lysis methodology. Our study aim was to validate a modified pre-lysis protocol against our standard post-lysis method for MRD detection of multiple myeloma (MM), chronic lymphocytic leukemia (CLL), and B-non Hodgkin lymphoma (B-NHL), to meet demand for deeper MRD assessment by flow cytometry. METHOD Clinical samples for MRD assessment of MM, CLL, and B-NHL (50, 30, and 30 cases, respectively) were prepared in parallel by pre and post-lysis methods for the initial validation. Total leukocytes, MRD, and median fluorescence intensity of antigen expression were compared as measures of sensitivity and antigen stability. Lymphocyte and granulocyte composition were compared, assessing relative sample processing stability. Sensitivity of the pre-lysis assay was monitored post validation for a further 18 months. RESULTS Pre-lysis achieved at least 10-4 sensitivity in 85% MM, 81% CLL, and 90% B-NHL samples versus 24%, 48%, and 26% by post-lysis, respectively, with stable antigen expression and leukocyte composition. Post validation over 18 months with technical expertise improving, pre-lysis permitted 10-5 MRD assessment in 69%, 86%, and 82% of the respective patient groups. CONCLUSION This modified pre-lysis procedure provides a sensitive, robust, time efficient, and relatively cost-effective alternative for MRD testing by MFC at 10-5 , facilitating clinically meaningful deeper response assessment for MM, CLL, and B-NHL. This method adaptation may facilitate more widespread adoption of highly sensitive flow cytometry-based MRD assessment.
Collapse
Affiliation(s)
- Emma Bayly
- Pathology Department, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.,Clinical Haematology, Victorian Comprehensive Cancer Centre, Melbourne, Victoria, Australia
| | - Vuong Nguyen
- Pathology Department, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia
| | - Adrian Binek
- Pathology Department, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia
| | - Anna Piggin
- Pathology Department, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.,Clinical Haematology, Victorian Comprehensive Cancer Centre, Melbourne, Victoria, Australia
| | - Kylie Baldwin
- Pathology Department, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia
| | - David Westerman
- Pathology Department, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.,Clinical Haematology, Victorian Comprehensive Cancer Centre, Melbourne, Victoria, Australia.,Sir Peter MacCallum Department of Oncology, Peter MacCallum Cancer Centre, The University of Melbourne, Parkville, Victoria, Australia
| | - Neil Came
- Pathology Department, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.,Sir Peter MacCallum Department of Oncology, Peter MacCallum Cancer Centre, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
6
|
Roshal M. Measurable disease evaluation in patients with myeloma. Best Pract Res Clin Haematol 2020; 33:101154. [PMID: 32139019 DOI: 10.1016/j.beha.2020.101154] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Accepted: 01/30/2020] [Indexed: 01/09/2023]
Abstract
Recent years saw significant breakthroughs in treatment of multiple myeloma. Durable remissions are now seen in a significant proportion of patients with the previously uniformly incurable and progressive disease. Yet because of deep suppression of the neoplastic myeloma clones by the newer therapies, older disease monitoring techniques are insufficient to distinguish between the patients at high risk of imminent relapse and those in whom durable remission is expected. This review briefly describes prognostic and therapeutic implications of measurable disease (MRD) evaluation, explains why deep MRD evaluation is needed for patients without morphologic evidence of disease, and reviews the state of the art of evaluation of myeloma MRD by flow cytometry.
Collapse
Affiliation(s)
- Mikhail Roshal
- Hematopathology Service, Department of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
| |
Collapse
|
7
|
Finak G, Jiang W, Gottardo R. CytoML for cross-platform cytometry data sharing. Cytometry A 2019; 93:1189-1196. [PMID: 30551257 PMCID: PMC6443375 DOI: 10.1002/cyto.a.23663] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2018] [Revised: 09/11/2018] [Accepted: 10/02/2018] [Indexed: 12/20/2022]
Abstract
CytoML is an R/Bioconductor package that enables cross‐platform import, export, and sharing of gated cytometry data. It currently supports Cytobank, FlowJo, Diva, and R, allowing users to import gated cytometry data from commercial platforms into R. Once data are available in R, the data can be further manipulated. For example it can be combined with other computational and analytic approaches, and the results can be exported to FlowJo or Cytobank to be explored by researchers using those platforms. We demonstrate how CytoML and related R packages can be used as a tool to import, modify and export several samples stained with the T cell panel from the FlowCAP IV Lyoplate data set. Once imported, the gating is modified using computational approaches, and exported for visualization in Cytobank and FlowJo. We further show how CytoML can be used to import gated data from a publicly accessible mass cytometry experiment from Cytobank. CytoML is the only tool that allows such sharing of gated cytometry data between researchers working across different platforms, and it will serve as a useful tool for validating and verifying the reproducibility of analyses. © 2018 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of International Society for Advancement of Cytometry.
Collapse
Affiliation(s)
- Greg Finak
- Program in Biostatistics Bioinformatics and Epidemiology, Vaccine and Infectious Disease Division, Fred Hutchinson Cancer Research Center, Seattle, Western Australia
| | - Wenxin Jiang
- Program in Biostatistics Bioinformatics and Epidemiology, Vaccine and Infectious Disease Division, Fred Hutchinson Cancer Research Center, Seattle, Western Australia
| | - Raphael Gottardo
- Program in Biostatistics Bioinformatics and Epidemiology, Vaccine and Infectious Disease Division, Fred Hutchinson Cancer Research Center, Seattle, Western Australia
| |
Collapse
|
8
|
Diks AM, Bonroy C, Teodosio C, Groenland RJ, de Mooij B, de Maertelaere E, Neirynck J, Philippé J, Orfao A, van Dongen JJM, Berkowska MA. Impact of blood storage and sample handling on quality of high dimensional flow cytometric data in multicenter clinical research. J Immunol Methods 2019; 475:112616. [PMID: 31181213 DOI: 10.1016/j.jim.2019.06.007] [Citation(s) in RCA: 56] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2019] [Revised: 05/21/2019] [Accepted: 06/04/2019] [Indexed: 01/20/2023]
Abstract
Obtaining reliable and reproducible high quality data in multicenter clinical research settings requires design of optimal standard operating procedures. While the need for standardization in sample processing and data analysis is well-recognized, the impact of sample handling in the pre-analytical phase remains underestimated. We evaluated the impact of sample storage time (≈transport time) and temperature, type of anticoagulant, and limited blood volume on reproducibility of flow cytometric studies. EDTA and Na-Heparin samples processed with the EuroFlow bulk lysis protocol, stained and stored at 4 °C showed fairly stable expression of cell surface markers and distribution of the major leukocyte populations for up to 72 h. Additional sample fixation (1% PFA, Fix & Perm) did not have any beneficial effects. Blood samples stored for <24 h at room temperature before processing and staining seemed suitable for reliable immunophenotyping, although losses in absolute cell numbers were observed. The major losses were observed in myeloid cells and monocytes, while lymphocytes seemed less affected. Expression of cell surface markers and population distribution were more stable in Na-Heparin blood than in EDTA blood. However, storage of Na-Heparin samples was associated with faster decrease in leukocyte counts over time. Whole blood fixation strategies (Cyto-Chex, TransFix) improved long-term population distribution, but were detrimental for expression of cellular markers. The main conclusions from this study on healthy donor blood samples were successfully confirmed in EDTA clinical (patient) blood samples with different time delays until processing. Finally, we recognized the need for adjustments in bulk lysis in case of insufficient blood volumes. Despite clear overall conclusions, individual markers and cell populations had different preferred conditions. Therefore, specific guidelines for sample handling should always be adjusted to the clinical application and the main target leukocyte population.
Collapse
Affiliation(s)
- A M Diks
- Department of Immunohematology and Blood Transfusion, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands
| | - C Bonroy
- Department of Diagnostic Sciences, Ghent University, Ghent, Belgium; Department of Laboratory Medicine, Ghent University Hospital, Ghent, Belgium
| | - C Teodosio
- Department of Immunohematology and Blood Transfusion, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands
| | - R J Groenland
- Department of Immunohematology and Blood Transfusion, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands
| | - B de Mooij
- Department of Immunohematology and Blood Transfusion, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands
| | - E de Maertelaere
- Department of Laboratory Medicine, Ghent University Hospital, Ghent, Belgium
| | - J Neirynck
- Department of Laboratory Medicine, Ghent University Hospital, Ghent, Belgium
| | - J Philippé
- Department of Diagnostic Sciences, Ghent University, Ghent, Belgium; Department of Laboratory Medicine, Ghent University Hospital, Ghent, Belgium
| | - A Orfao
- Cancer Research Centre (IBMCC, USAL-CSIC; CIBERONC CB16/12/00400), Institute for Biomedical Research of Salamanca (IBSAL), Department of Medicine and Cytometry Service (NUCLEUS Research Support Platform), University of Salamanca (USAL), Salamanca, Spain
| | - J J M van Dongen
- Department of Immunohematology and Blood Transfusion, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands.
| | - M A Berkowska
- Department of Immunohematology and Blood Transfusion, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands
| |
Collapse
|
9
|
Blum A, Haussmann K, Streitz M, Schlickeiser S, Tietze-Buerger C, Blau IW, Uharek L. Standardized assay for assessment of minimal residual disease in blood, bone marrow and apheresis from patients with plasma cell myeloma. Sci Rep 2019; 9:2922. [PMID: 30814612 PMCID: PMC6393516 DOI: 10.1038/s41598-019-39631-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Accepted: 01/24/2019] [Indexed: 12/21/2022] Open
Abstract
The recent advances in myeloma treatment result in significantly better outcomes, defined as increased progression free survival (PFS) and overall survival (OS). Since there is a proven correlation between the extend of response and prolonged survival, there is an urgent need for highly sensitive assays for the detection of minimal residual disease (MRD). Next generation flow cytometry has become a valuable approach for sensitive evaluation of the depth of complete response (CR). Here, we report the diagnostic performance and validation results of a single-tube 9-color panel assay. The validation design included intra-assay analysis measuring accuracy, inter-assay analysis estimating method’s linearity and precision and inter-assay analysis evaluating repeatability. Furthermore, in inter-operator analysis assessed the comparability of the result analysis of different operators. Staining stability was evaluated in age-of-stain experiments. Our validation results show that a reliable detection of residual myeloma cells is feasible to a detection level of 10−5 with a single-tube assay for a variety of materials (peripheral blood, bone marrow and stem cell apheresis). This study establishes highly sensitive, fully standardized approach for MRD detection in myeloma that is ready for implementation in routine diagnostic laboratories.
Collapse
Affiliation(s)
- Agnieszka Blum
- Charité Stem Cell Facility, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Augustenburger Platz 1, Berlin, 13353, Germany.
| | - Katy Haussmann
- Charité Stem Cell Facility, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Augustenburger Platz 1, Berlin, 13353, Germany
| | - Mathias Streitz
- Institute of Medical Immunology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Augustenburger Platz 1, Berlin, 13353, Germany
| | - Stephan Schlickeiser
- Institute of Medical Immunology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Augustenburger Platz 1, Berlin, 13353, Germany
| | - Carola Tietze-Buerger
- Charité Stem Cell Facility, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Augustenburger Platz 1, Berlin, 13353, Germany
| | - Igor Wolfgang Blau
- Department of Haematology, Oncology, Tumor Immunology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Augustenburger Platz 1, Berlin, 13353, Germany
| | - Lutz Uharek
- Charité Stem Cell Facility, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Augustenburger Platz 1, Berlin, 13353, Germany
| |
Collapse
|
10
|
Spurgeon BE, Naseem KM. Platelet Flow Cytometry: Instrument Setup, Controls, and Panel Performance. CYTOMETRY PART B-CLINICAL CYTOMETRY 2019; 98:19-27. [DOI: 10.1002/cyto.b.21774] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2018] [Revised: 01/05/2019] [Accepted: 01/31/2019] [Indexed: 11/10/2022]
Affiliation(s)
| | - Khalid M. Naseem
- Leeds Institute of Cardiovascular and Metabolic MedicineUniversity of Leeds Leeds UK
| |
Collapse
|
11
|
Came N. Should we be routinely testing for circulating clonal plasma cells in patients with multiple myeloma? CYTOMETRY PART B-CLINICAL CYTOMETRY 2018; 94:559. [PMID: 30240163 DOI: 10.1002/cyto.b.21741] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
12
|
Soh KT, Tario JD, Wallace PK. Diagnosis of Plasma Cell Dyscrasias and Monitoring of Minimal Residual Disease by Multiparametric Flow Cytometry. Clin Lab Med 2018; 37:821-853. [PMID: 29128071 DOI: 10.1016/j.cll.2017.08.001] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Plasma cell dyscrasia (PCD) is a heterogeneous disease that has seen a tremendous change in outcomes due to improved therapies. Over the past few decades, multiparametric flow cytometry has played an important role in the detection and monitoring of PCDs. Flow cytometry is a high-sensitivity assay for early detection of minimal residual disease (MRD) that correlates well with progression-free survival and overall survival. Before flow cytometry can be effectively implemented in the clinical setting, sample preparation, panel configuration, analysis, and gating strategies must be optimized to ensure accurate results. Current consensus methods and reporting guidelines for MRD testing are discussed.
Collapse
Affiliation(s)
- Kah Teong Soh
- Department of Flow and Image Cytometry, Roswell Park Cancer Institute, Elm and Carlton Streets, Buffalo, NY 14263, USA.
| | - Joseph D Tario
- Department of Flow and Image Cytometry, Roswell Park Cancer Institute, Elm and Carlton Streets, Buffalo, NY 14263, USA
| | - Paul K Wallace
- Department of Flow and Image Cytometry, Roswell Park Cancer Institute, Elm and Carlton Streets, Buffalo, NY 14263, USA
| |
Collapse
|
13
|
Roshal M. Minimal Residual Disease Detection by Flow Cytometry in Multiple Myeloma: Why and How? Semin Hematol 2018; 55:4-12. [PMID: 29759152 DOI: 10.1053/j.seminhematol.2018.02.011] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Accepted: 02/27/2018] [Indexed: 11/11/2022]
Abstract
The outlook for myeloma patients has steadily improved with the introduction of newer drug combinations in recent years. Unlike older therapies that largely achieved only modest levels of neoplastic clone reduction, the newer drug combinations have led to deeper suppression of myeloma clones in most patients. Frequently the neoplastic clones become undetectable with traditional disease evaluation approaches. Recent studies using ultrasensitive disease monitoring have demonstrated that patients with disease undetectable by traditional techniques show wide heterogeneity in disease levels varying by several orders of magnitude. Moreover, measurement of the depth of disease suppression even at very low level has emerged as the most powerful prognostication tool in myeloma. Minimal (or measurable) residual disease (MRD) evaluation has also been proposed as a relevant tool in assessment of drug efficacy and in selection of further therapeutic options. In the face of the robust MRD measurement utility data, it has become critical to develop widely applicable disease monitoring techniques that can be applied to more patients in a variety of clinical setting. Both DNA-based and flow cytometry-based approaches have been successfully developed for this purpose achieving sensitivity approaching 1 neoplastic cell in a million. This review article focuses on the theoretical and practical aspects and challenges of deep MRD monitoring in myeloma by flow cytometry. Challenges of flow cytometric disease monitoring in the era of antigen-directed therapy are also discussed.
Collapse
Affiliation(s)
- Mikhail Roshal
- Hematopathology Service, Department of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY.
| |
Collapse
|
14
|
David R, Talbot E, Allen B, Wilson A, Arshad U, Doherty A. The development of an in vitro Pig-a assay in L5178Y cells. Arch Toxicol 2018; 92:1609-1623. [PMID: 29362862 DOI: 10.1007/s00204-018-2157-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Accepted: 01/17/2018] [Indexed: 12/01/2022]
Abstract
A recent flow cytometry-based in vivo mutagenicity assay involves the hemizygous phosphatidylinositol class A (Pig-a) gene. Pig-a forms the catalytic subunit of N-acetylglucosaminyltransferase required for glycophosphatidylinositol (GPI) anchor biosynthesis. Mutations in Pig-a prevent GPI-anchor synthesis resulting in loss of cell-surface GPI-linked proteins. The aim of the current study was to develop and validate an in vitro Pig-a assay in L5178Y mouse lymphoma cells. Ethyl methanesulfonate (EMS)-treated cells (186.24-558.72 µg/ml; 24 h) were used for method development and antibodies against GPI-linked CD90.2 and stably expressed CD45 were used to determine GPI-status by flow cytometry. Antibody concentration and incubation times were optimised (0.18 µg/ml, 30 min, 4 °C) and Zombie Violet™ (viability marker; 0.5%, 30 min, RT) was included. The optimum phenotypic expression period was 8 days. The low background mutation frequency of GPI-deficiency [GPI(-)] in L5178Y cells (0.1%) constitutes a rare event, thus flow cytometry acquisition parameters were optimised; 104 cells were measured at medium flow rate to ensure a CV ≤ 30%. Spiking known numbers of GPI(-) cells into a wild-type population gave high correlation between measured and spiked numbers (R2 0.999). We applied the in vitro Pig-a assay to a selection of well-validated genotoxic and non-genotoxic compounds. EMS, N-ethyl-N-nitrosourea and 4-nitroquinoline-N-oxide dose dependently increased numbers of GPI(-) cells, while etoposide, mitomycin C, and a bacterial-specific mutagen did not. Cycloheximide and sodium chloride were negative. Sanger sequencing revealed Pig-a mutations in the GPI(-) clones. In conclusion, this in vitro Pig-a assay could complement the in vivo version, and follow up weak Ames positives and late-stage human metabolites or impurities.
Collapse
Affiliation(s)
- Rhiannon David
- Genetic Toxicology, Discovery Safety, Drug Safety and Metabolism, IMED Biotech Unit, AstraZeneca, Cambridge, UK.
| | - Emily Talbot
- Genetic Toxicology, Discovery Safety, Drug Safety and Metabolism, IMED Biotech Unit, AstraZeneca, Cambridge, UK
| | - Bethany Allen
- Genetic Toxicology, Discovery Safety, Drug Safety and Metabolism, IMED Biotech Unit, AstraZeneca, Cambridge, UK
| | - Amy Wilson
- Genetic Toxicology, Discovery Safety, Drug Safety and Metabolism, IMED Biotech Unit, AstraZeneca, Cambridge, UK
| | - Usman Arshad
- Genetic Toxicology, Discovery Safety, Drug Safety and Metabolism, IMED Biotech Unit, AstraZeneca, Cambridge, UK
| | - Ann Doherty
- Genetic Toxicology, Discovery Safety, Drug Safety and Metabolism, IMED Biotech Unit, AstraZeneca, Cambridge, UK
| |
Collapse
|
15
|
[Expert consensus on minimal residual disease detection of acute leukemia and plasma cell neoplasms by multi-parameter flow cytometry]. ZHONGHUA XUE YE XUE ZA ZHI = ZHONGHUA XUEYEXUE ZAZHI 2017; 38:1001-1011. [PMID: 29365391 PMCID: PMC7342185 DOI: 10.3760/cma.j.issn.0253-2727.2017.12.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Indexed: 11/09/2022]
|
16
|
Flow cytometric analysis of CD64 expression pattern and density in the diagnosis of acute promyelocytic leukemia: a multi-center study in Shanghai, China. Oncotarget 2017; 8:80625-80637. [PMID: 29113330 PMCID: PMC5655225 DOI: 10.18632/oncotarget.20814] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2017] [Accepted: 08/23/2017] [Indexed: 12/19/2022] Open
Abstract
No unified immunophenotypic profiles and corresponding analytic strategies have been established for the rapid diagnosis of acute promyelocytic leukemia (APL) using flow cytometry (FCM). Here we describe a characteristic immunophenotypic panel that can rapidly and accurately distinguish APL from other types of adult acute myeloid leukemia (AML) using only FCM. By comparing APL cells and non-APL AML cells that share APL common immunophenotypes (CD34−CD117+HLA−DR−) we found that CD64 was a significant factor that differentiated APL from other AMLs. Further retrospective analyses of 205 APL and 629 non-APL AML patients from different hematology centers showed that either the CD64dim and homoCD13+homo CD33+homoMPO+ (myeloperoxidase) CD11c− panel or the CD64dim and homoCD13+homo CD33+homoMPO+ CD11c+CD10−CD117+ SSChigh (high side scatter signal) panel could distinguish APL from non-APL AML patients with nearly 100% sensitivity, specificity and accuracy. Moreover, relative quantification of CD64 expression enhanced the applicability of our APL diagnostic immunophenotypic panels (ADI-panels) in different hematology centers. Application of the ADI-panels will decrease diagnosis time and improve personalized treatment for APL, a life-threatening disease with very rapid progression.
Collapse
|
17
|
MRD detection in multiple myeloma: comparison between MSKCC 10-color single-tube and EuroFlow 8-color 2-tube methods. Blood Adv 2017; 1:728-732. [PMID: 29296716 DOI: 10.1182/bloodadvances.2016003715] [Citation(s) in RCA: 80] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2016] [Accepted: 02/22/2017] [Indexed: 11/20/2022] Open
Abstract
In patients with multiple myeloma, obtaining posttreatment minimal residual disease (MRD) negativity is associated with longer progression-free survival and overall survival. Here, we compared the diagnostic performance of a single 10-color tube with that of a EuroFlow 8-color 2-tube panel for MRD testing. Bone marrow samples from 41 multiple myeloma patients were tested in parallel using the 2 approaches. Compared with the sum of the cells from the EuroFlow two 8-color tubes, the Memorial Sloan Kettering Cancer Center (MSKCC) single 10-color tube had a slight reduction in total cell number with a mean ratio of 0.85 (range, 0.57-1.46; P < .05), likely attributable to permeabilization of the cells. Percent of plasma cells showed a high degree of concordance (r2 = 0.97) as did normal plasma cells (r2 = 0.96), consistent with no selective plasma cell loss. Importantly, concordant measurement of residual disease burden was seen with abnormal plasma cells (r2 = 0.97). The overall concordance between the 2 tests was 98%. In 1 case, there was a discrepancy near the limit of detection of both tests in favor of the slightly greater theoretical sensitivity of the EuroFlow 8-color 2-tube panel (analytical sensitivity limit of MSKCC single 10-color tube: 6 cells in 1 million with at least 3 million cell acquisitions; EuroFlow 8-color 2-tube panel: 2 cells in 1 million with the recommended 10 million cell acquisitions).
Collapse
|
18
|
Preffer FI, Yuan CM, Lin P, Stetler-Stevenson M, Marti GE. Introduction to multiple myeloma special issue: The flow cytometric detection of minimal residual disease. CYTOMETRY PART B-CLINICAL CYTOMETRY 2016; 90:9-10. [PMID: 26780351 DOI: 10.1002/cyto.b.21342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|