1
|
Huang J, Hou L, Bian X, Chang K. Analysis of intracellular reactive oxygen species by micellar electrokinetic capillary chromatography with laser-induced-fluorescence detector. J LIQ CHROMATOGR R T 2019. [DOI: 10.1080/10826076.2019.1625369] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Jianping Huang
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, China
- Henan Engineering Research Center of Water Pollution and Soil Damage Remediation, Zhengzhou, China
- Henan Key Laboratory of Water Environment Simulation and Treatment, Zhengzhou, China
| | - Lijun Hou
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, China
| | - Xiaozheng Bian
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, China
| | - Kai Chang
- School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, China
| |
Collapse
|
2
|
Xue Z, Yin B, Wang H, Li M, Rao H, Liu X, Zhou X, Lu X. An organic indicator functionalized graphene oxide nanocomposite-based colorimetric assay for the detection of sarcosine. NANOSCALE 2016; 8:5488-96. [PMID: 26902537 DOI: 10.1039/c6nr00005c] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Rapid detection of sarcosine is a key requirement for both diagnosis and treatment of disease. We report here a simple yet sensitive colorimetric nanocomposite platform for rapid detection of sarcosine in alkaline media. The approach exploited the benefits of a rapid color-producing reaction between an organic indicator, 1,2-naphthoquinone-4-sulphonic acid sodium salt (NQS), and the analyte of sarcosine species as well as the good catalytic ability of graphene oxide (GO) to the formation of highly colored products due to its good water dispersibility, extremely large surface area and facile surface modification. As a result, a NQS functionalized GO nanocomposite through π-π stacking has been demonstrated to be useful as a highly efficient catalyst system for the selective and sensitive colorimetric determination of sarcosine by providing a nanocomposite-amplified colorimetric response. Meanwhile, the strategy offered excellent selectivity toward sarcosine species against other amino acids as well as a satisfying detection limit of 0.73 μM. More importantly, by using an electrochemical method, a credible sensing mechanism of GO nanocomposite-based colorimetric platform for a special analyte determination can be easily verified and elucidated, which also provides an attractive alternative to conventional characterization strategies.
Collapse
Affiliation(s)
- Zhonghua Xue
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China.
| | - Bo Yin
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China.
| | - Hui Wang
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China.
| | - Mengqian Li
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China.
| | - Honghong Rao
- School of chemistry & environmental science, Lanzhou City University, Lanzhou, 730070, China
| | - Xiuhui Liu
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China.
| | - Xinbin Zhou
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China.
| | - Xiaoquan Lu
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China.
| |
Collapse
|
3
|
Gupta P, Rosy R, Goyal RN. A carbon ion beam irradiated MWCNT/AuNPs composite sensor for a sensitive assay of purine-nucleosides of DNA. RSC Adv 2015. [DOI: 10.1039/c5ra18970e] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Sensor for purine nucleosides has been developed using irradiation with high energy carbon ion beam.
Collapse
Affiliation(s)
- Pankaj Gupta
- Department of Chemistry
- Indian Institute of Technology Roorkee
- Roorkee-247667
- India
| | - Rosy Rosy
- Department of Chemistry
- Indian Institute of Technology Roorkee
- Roorkee-247667
- India
| | - Rajendra N. Goyal
- Department of Chemistry
- Indian Institute of Technology Roorkee
- Roorkee-247667
- India
| |
Collapse
|
4
|
Henley WH, Ramsey JM. High electric field strength two-dimensional peptide separations using a microfluidic device. Electrophoresis 2012; 33:2718-24. [PMID: 22965717 PMCID: PMC3787844 DOI: 10.1002/elps.201200069] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
New instrumentation has been developed to improve the resolution, efficiency, and speed of microfluidic 2D separations using MEKC coupled to high field strength CE. Previously published 2D separation instrumentation [Ramsey, J. D. et al., Anal. Chem. 2003, 75, 3758-3764] from our group was limited to a maximum potential difference of 8.4 kV, resulting in an electric field strength of only approximately 200 V/cm in the first dimension. The circuit described in this report has been designed to couple a higher voltage supply with a rapidly switching, lower voltage supply to utilize the best features of each. Voltages applied in excess of 20 kV lead to high electric field strength separations in both dimensions, increasing the separation resolution, efficiency, and peak capacity while reducing the required analysis time. Detection rates as high as six peptides per second (based on total analysis time) were observed for a model protein tryptic digest separation. Additionally, higher applied voltages used in conjunction with microfluidic chips with longer length channels maintained higher electric field strengths and produced peak capacities of over 4000 for some separations. Total separation time in these longer channel devices was comparable to that obtained in short channels at low field strength; however, resolving power improved approximately threefold.
Collapse
Affiliation(s)
- W Hampton Henley
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| | | |
Collapse
|
5
|
Puangpila C, Petsom A, Nhujak T. Theoretical models of separation selectivity for charged compounds in micellar electrokinetic chromatography. Electrophoresis 2010; 32:203-9. [DOI: 10.1002/elps.201000405] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2010] [Revised: 10/18/2010] [Accepted: 10/18/2010] [Indexed: 11/05/2022]
|
6
|
Markuszewski MJ, Struck W, Waszczuk-Jankowska M, Kaliszan R. Metabolomic approach for determination of urinary nucleosides as potential tumor markers using electromigration techniques. Electrophoresis 2010; 31:2300-10. [PMID: 20564268 DOI: 10.1002/elps.200900785] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
In the postgenome-sequencing era, several large projects have been running recently. Proteomics and other analysis or structural biology are the most active today. Since the late 1990 s, metabolomics has been gaining importance in systems biology, as it provides real-world end points that complement and help in the interpretation of genomic and proteomic data. Comprehensive information about the level changes of numerous metabolites present in the analyzed samples is essential in metabolomic studies. Therefore, the applied analytical techniques must be suitable for the simultaneous analysis of a diverse range of low-molecular-mass endogenous metabolites such as nucleosides at various concentrations and in different matrices, in particular, in urine and serum. In the view of metabolomic study, this domain is obviously significant to understand specific humans' reactions and it can be perceived as a diagnostic and predictive tool in pathological reactions. Since the term "metabolom" has occurred in common scientific use, there have been many publications about possible ways of analysis of nucleosides as metabolites of either oxidative DNA damage or RNA's turnover that are used as the potential tumor markers. Besides, the availability of fast, reproducible and easy to apply analytical techniques that would allow the identification of a large number of metabolites is highly desirable since they may provide detailed information about the progression of a pathological process. This paper, which describes the most relevant electromigration techniques, covers the period starting from the review of Karl H. Schram (Mass Spectrom. Rev. 1998, 17, 131-251) up to the beginning of 2009.
Collapse
Affiliation(s)
- Michal J Markuszewski
- Department of Toxicology, Ludwik Rydygier Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland.
| | | | | | | |
Collapse
|
7
|
Liu Q, Jia L, Hu C. On-Line Concentration Methods for Analysis of Fat-Soluble Vitamins by MEKC. Chromatographia 2010. [DOI: 10.1365/s10337-010-1608-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
8
|
Liu Q, Liu Y, Guan Y, Jia L. Comparison of field-enhanced and pressure-assisted field-enhanced sample injection techniques for the analysis of water-soluble vitamins using CZE. J Sep Sci 2009; 32:1011-7. [DOI: 10.1002/jssc.200800598] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
9
|
Hoeman KW, Culbertson CT. A novel, environmentally friendly sodium lauryl ether sulfate-, cocamidopropyl betaine-, cocamide monoethanolamine-containing buffer for MEKC on microfluidic devices. Electrophoresis 2008; 29:4900-5. [DOI: 10.1002/elps.200800463] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
10
|
García-Pérez I, Vallejo M, García A, Legido-Quigley C, Barbas C. Metabolic fingerprinting with capillary electrophoresis. J Chromatogr A 2008; 1204:130-9. [DOI: 10.1016/j.chroma.2008.07.025] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2008] [Revised: 07/01/2008] [Accepted: 07/08/2008] [Indexed: 10/21/2022]
|
11
|
Jouyban A, Kenndler E. Impurity analysis of pharmaceuticals using capillary electromigration methods. Electrophoresis 2008; 29:3531-51. [DOI: 10.1002/elps.200800054] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
12
|
Abstract
Recent research and development efforts concerning polymeric pseudostationary phases (PSPs) for electrokinetic chromatography are reviewed. The introduction of new materials, characterization of structural effects on performance and selectivity, applications, and the use of polymeric PSPs with mass spectrometric detection are considered. Very interesting results concerning the effects of polymer structure have been reported. Significant developments have also been reported in the development of novel applications of polymeric PSPs, particularly for sample preconcentration using micellar affinity gradient focusing. The use of mass spectrometric detection with electrokinetic chromatography has seen significant development, and recent reports indicate that this is a robust and sensitive approach.
Collapse
Affiliation(s)
- Christopher P Palmer
- Australian Centre for Research, on Separation Science (ACROSS), School of Chemistry, University of Tasmania, Hobart, Tasmania, Australia.
| |
Collapse
|
13
|
Silva CA, Pereira EA, Micke GA, Farah JPS, Tavares MFM. Mixture-designed electrolytes for the MEKC separation of natural and synthetic steroids. Electrophoresis 2008; 28:3722-30. [PMID: 17941121 DOI: 10.1002/elps.200700511] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
In this work, the separation of 11 natural and synthetic steroids was studied using MEKC electrolytes modified by property-selected organic solvents: ethanol, ACN, and THF. The interplay between electrophoretic behavior and structural features was disclosed and the effects of organic modifiers to modulate retention and to alter selectivity were discussed in terms of system linear solvation energy relationships (LSER). The LSER indicated the total organic solvent percentage in the electrolyte as a major parameter to control retention and as a minor contribution, the hydrogen bond acidity. By evaluating the electropherograms obtained from mixture-designed electrolytes, a favorable separation condition for all solutes was achieved in ca. 25 min with an electrolyte composed of 20 mmol/L sodium tetraborate at pH 9.4, 20 mmol/L SDS and 20% EtOH (0.80% CV for migration time and 2.5% CV for peak area, n = five consecutive injections). The applicability of the proposed separation condition was demonstrated by the inspection of estrogens in urine sample (puberty stage).
Collapse
Affiliation(s)
- Claudinei A Silva
- Institute of Chemistry, University of São Paulo, São Paulo, SP, Brazil
| | | | | | | | | |
Collapse
|
14
|
Feng YL, Zhu J. On-line enhancement technique for the analysis of nucleotides using capillary zone electrophoresis/mass spectrometry. Anal Chem 2007; 78:6608-13. [PMID: 16970340 DOI: 10.1021/ac0608568] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A new on-line capillary zone electrophoresis/mass spectrometry (CZE/MS), constant pressure-assisted electrokinetic injection (PAEKI), for the analysis of negatively charged nucleotides is reported. PAEKI uses an applied pressure to counterbalance the reverse electroosmotic flow in the capillary column during sample injection, while taking advantage of the field amplification in the sample medium. At balance, the running buffer in the column is stationary, permitting potentially unlimited injection time, and hence unlimited sample enrichment power. The ability of PAEKI to maintain a narrow sample zone over a long injection time seems to be a result of the formation of a high ion concentration band at the boundary of the two media due to rapid deceleration of the migrating ions at the boundary. The injected amount of analytes proved to be linearly proportional to both the field amplification factor, which is expressed as the ratio of resistivities of sample medium to running buffer, and the injection time, which extended up to 1200 s in CZE/MS and 3600 s in CZE/UV. For a 300-s on-line PAEKI injection in CZE/MS, 3 orders of magnitude sample enhancement (5000-fold enrichment) could be observed for the four single nucleotides without compromising separation efficiency and peak shape, and an achievement of detection limits between 0.04 and 0.07 ng/mL. With appropriate sample cleanup, PAEKI can be used in the analysis of single nucleotides in enzyme-digested DNA.
Collapse
Affiliation(s)
- Yong-Lai Feng
- Chemistry Research Division, Health Canada, AL 0800C, EHC, Tunney's Pasture, Ottawa, Ontario, Canada K1A 0L2
| | | |
Collapse
|
15
|
Abstract
Proteomic technologies are used with increasing frequency in the renal community. In this review, we highlight the use in renal research of a number of available techniques including two-dimensional gel electrophoresis, liquid chromatography/mass spectrometry, surface-enhanced laser desorption/ionization, capillary electrophoresis/mass spectrometry, and antibody and tissue arrays. These techniques have been used to identify proteins or changes in proteins specific to regions of the kidney or associated with renal diseases or toxicity. They have also been used to examine protein expression changes and posttranslational modifications of proteins during signaling. A number of studies have used proteomic methodologies to look for diagnostic biomarkers in body fluids. The rapid rate of development of the technologies along with the combination of classic physiological and biochemical techniques with proteomics will enable new discoveries.
Collapse
Affiliation(s)
- Michael G Janech
- Medical University of South Carolina, Ralph H. Johnson Veterans Affairs Medical Center, Charleston, SC 29425-2220, USA
| | | | | |
Collapse
|
16
|
Szymańska E, Markuszewski MJ, Capron X, van Nederkassel AM, Heyden YV, Markuszewski M, Krajka K, Kaliszan R. Increasing conclusiveness of metabonomic studies by chem-informatic preprocessing of capillary electrophoretic data on urinary nucleoside profiles. J Pharm Biomed Anal 2006; 43:413-20. [PMID: 17000071 DOI: 10.1016/j.jpba.2006.08.015] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2006] [Revised: 08/16/2006] [Accepted: 08/16/2006] [Indexed: 10/24/2022]
Abstract
Nowadays, bioinformatics offers advanced tools and procedures of data mining aimed at finding consistent patterns or systematic relationships between variables. Numerous metabolites concentrations can readily be determined in a given biological system by high-throughput analytical methods. However, such row analytical data comprise noninformative components due to many disturbances normally occurring in analysis of biological samples. To eliminate those unwanted original analytical data components advanced chemometric data preprocessing methods might be of help. Here, such methods are applied to electrophoretic nucleoside profiles in urine samples of cancer patients and healthy volunteers. The electrophoretic nucleoside profiles were obtained under following conditions: 100 mM borate, 72.5 mM phosphate, 160 mM SDS, pH 6.7; 25 kV voltage, 30 degrees C temperature; untreated fused silica capillary 70 cm effective length, 50 microm I.D. Different most advanced preprocessing tools were applied for baseline correction, denoising and alignment of electrophoretic data. That approach was compared to standard procedure of electrophoretic peak integration. The best results of preprocessing were obtained after application of the so-called correlation optimized warping (COW) to align the data. The principal component analysis (PCA) of preprocessed data provides a clearly better consistency of the nucleoside electrophoretic profiles with health status of subjects than PCA of peak areas of original data (without preprocessing).
Collapse
Affiliation(s)
- E Szymańska
- Department of Biopharmaceutics and Pharmacodynamics, Medical University of Gdańsk, Gen. J. Hallera 107, 80-416 Gdańsk, Poland
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Sung WC, Chen SH. Pharmacokinetic applications of capillary electrophoresis: A review on recent progress. Electrophoresis 2006; 27:257-65. [PMID: 16315169 DOI: 10.1002/elps.200500617] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This article covers recent publications from 2003 to 2005 on the subject of pharmacokinetic applications of CE. Many analytical methods were validated and more importantly, they were shown to have sufficient sensitivities to access pharmacokinetic data on different models. Because of unique advantages, such as simplified sample preparation methods, small sample amount required, high separation power, and speedy analysis, CE-based assays were found to gain popularity not only as a second method but also as a major method for many pharmacokinetic studies.
Collapse
Affiliation(s)
- Wang-Chou Sung
- Department of Chemistry, National Cheng Kung University, Tainan, Taiwan
| | | |
Collapse
|
18
|
Kurien BT, Patel NC, Porter AC, D'Souza A, Miller D, Matsumoto H, Wang H, Scofield RH. Prolidase deficiency and the biochemical assays used in its diagnosis. Anal Biochem 2005; 349:165-75. [PMID: 16298326 DOI: 10.1016/j.ab.2005.10.018] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2005] [Revised: 10/10/2005] [Accepted: 10/11/2005] [Indexed: 11/16/2022]
Affiliation(s)
- Biji T Kurien
- Arthritis and Immunology Program, Oklahoma Medical Research Foundation, Oklahoma City, OK 73104, USA.
| | | | | | | | | | | | | | | |
Collapse
|