1
|
Green Assessment of Chromatographic Methods Used for the Analysis of Four Methamphetamine Combinations with Commonly Abused Drugs. SEPARATIONS 2022. [DOI: 10.3390/separations9070156] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Numerous agents with anxiolytic or stimulant effects have the potential to be overused, and their misuse is associated with serious side effects. In Saudi Arabia, the estimated percentage of Saudis who abuse drugs is around 7–8% and the age range is 12–22 years. Methamphetamine, captagon, tramadol, heroin, and cannabis/cannabinoids have been proven to be the most commonly abused drugs in Saudi Arabia, with methamphetamine being at the top of the list. The present study focuses on the chromatographic analytical methods used for the analysis of methamphetamine in combination with commonly abused drugs, aiming to point out the greenest among them. These mixtures have been chosen as they are analyzed periodically and frequently in criminal evidence and forensic medicine. Therefore, the chances of hazards for analysts and the environment are high if the mixtures are not handled appropriately. This study aims to compare 23 chromatographic methods used for the analysis of methamphetamine mixtures in four major combinations, and to assess their greenness by using three greenness assessment tools, namely, NEMI, ESA and AGREE, to recommend the greenest analytical method. The NEMI results were proven to have low discriminating abilities and, accordingly, the comparisons are based on ESA and AGREE scores. The analysis results show that the safest methods with the most eco-friendly results (based on ESA and AGREE) are the GC-MS method proposed by Mohammed et al. to analyze methamphetamine and captagon mixtures (ESA = 79 and AGREE = 0.57), the UHPLC–MS-MS method proposed by Busardò et al. to analyze methamphetamine and cannabis/cannabinoid mixtures (ESA = 78 and AGREE = 0.57), the LC-MS method proposed by Herrin et al. to analyze methamphetamine and tramadol mixtures (ESA = 81 and AGREE = 0.56), and the LC-MS method proposed by Postigo-et al to analyze methamphetamine and heroin mixtures (ESA = 76 and AGREE = 0.58).
Collapse
|
2
|
Fanali S. An overview to nano-scale analytical techniques: Nano-liquid chromatography and capillary electrochromatography. Electrophoresis 2017; 38:1822-1829. [PMID: 28256745 DOI: 10.1002/elps.201600573] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2016] [Revised: 02/17/2017] [Accepted: 02/21/2017] [Indexed: 01/04/2023]
Abstract
Nano-liquid chromatography (nano-LC) and CEC are microfluidic techniques mainly used for analytical purposes. They have been applied to the separation and analysis of a large number of compounds, e.g., peptides, proteins, drugs, enantiomers, antibiotics, pesticides, nutraceutical, etc. Analytes separation is carried out into capillaries containing selected stationary phase. The mobile phase is moved either by a pump (nano-LC) or by an EOF, respectively. The two tools can offer some advantages over conventional techniques, e.g., high selectivity, separation efficiency, resolution, short analysis time and consumption of low volumes of mobile phase. Flow rates in the range 50-800 nL/min are usually applied. The low flow rate reduces the chromatographic dilution increasing the mass sensitivity. Special attention must be paid in avoiding peak dispersion selecting the appropriate detector, injector and tube connection. Finally due to the low flow rate these microfluidic techniques can be easily coupled with mass spectrometry.
Collapse
Affiliation(s)
- Salvatore Fanali
- Institute of Chemical Methodologies, Italian National Research Council, Monterotondo, Italy
| |
Collapse
|
3
|
Declerck S, Vander Heyden Y, Mangelings D. Enantioseparations of pharmaceuticals with capillary electrochromatography: A review. J Pharm Biomed Anal 2016; 130:81-99. [PMID: 27156645 DOI: 10.1016/j.jpba.2016.04.024] [Citation(s) in RCA: 56] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Revised: 04/13/2016] [Accepted: 04/17/2016] [Indexed: 11/19/2022]
Abstract
The chiral separation of pharmaceuticals is one of the major research topics in the pharmaceutical industry. Chromatographic techniques are most frequently used in this context. Separations in capillary electrochromatography (CEC) are an alternative and achieved by chromatographic retention and electrophoretic mobility principles. As a result, CEC is characterized by a high selectivity and efficiency. The limited number of stationary phases specifically developed for CEC, the low number of commercially available CEC columns, the frits to maintain the stationary phase, which forms fragile spots in the columns, and the limited column robustness and reproducibility, make CEC not very attractive for industrial application. However, CEC is still applied and studied in the academic field. This review discusses the enantioseparation of drugs in CEC published during the last four years, with a critical view on the reproducibility and the practical utility of these applications.
Collapse
Affiliation(s)
- Sven Declerck
- Department of Analytical Chemistry and Pharmaceutical Technology (FABI), Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090 Brussels, Belgium.
| | - Yvan Vander Heyden
- Department of Analytical Chemistry and Pharmaceutical Technology (FABI), Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090 Brussels, Belgium.
| | - Debby Mangelings
- Department of Analytical Chemistry and Pharmaceutical Technology (FABI), Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090 Brussels, Belgium.
| |
Collapse
|
4
|
D'Orazio G, Hernández-Borges J, Asensio-Ramos M, Rodríguez-Delgado MÁ, Fanali S. Capillary electrochromatography and nano-liquid chromatography coupled to nano-electrospray ionization interface for the separation and identification of estrogenic compounds. Electrophoresis 2015; 37:356-62. [DOI: 10.1002/elps.201500327] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2015] [Revised: 09/27/2015] [Accepted: 10/05/2015] [Indexed: 11/06/2022]
Affiliation(s)
- Giovanni D'Orazio
- Instituto di Metodologie Chimiche; Consiglio Nazionale delle Ricerche (C.N.R.); Monterotondo Roma Italia
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias; Universidad de La Laguna (ULL); La Laguna Tenerife España
| | - Javier Hernández-Borges
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias; Universidad de La Laguna (ULL); La Laguna Tenerife España
| | - María Asensio-Ramos
- Instituto Volcanológico de Canarias (INVOLCAN); Parque Taoro Puerto de la Cruz Tenerife España
| | - Miguel Ángel Rodríguez-Delgado
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias; Universidad de La Laguna (ULL); La Laguna Tenerife España
| | - Salvatore Fanali
- Instituto di Metodologie Chimiche; Consiglio Nazionale delle Ricerche (C.N.R.); Monterotondo Roma Italia
| |
Collapse
|
5
|
Baciu T, Botello I, Borrull F, Calull M, Aguilar C. Capillary electrophoresis and related techniques in the determination of drugs of abuse and their metabolites. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.05.011] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
6
|
Posch TN, Pütz M, Martin N, Huhn C. Electromigrative separation techniques in forensic science: combining selectivity, sensitivity, and robustness. Anal Bioanal Chem 2014; 407:23-58. [PMID: 25381613 DOI: 10.1007/s00216-014-8271-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Revised: 10/12/2014] [Accepted: 10/14/2014] [Indexed: 01/27/2023]
Abstract
In this review we introduce the advantages and limitations of electromigrative separation techniques in forensic toxicology. We thus present a summary of illustrative studies and our own experience in the field together with established methods from the German Federal Criminal Police Office rather than a complete survey. We focus on the analytical aspects of analytes' physicochemical characteristics (e.g. polarity, stereoisomers) and analytical challenges including matrix tolerance, separation from compounds present in large excess, sample volumes, and orthogonality. For these aspects we want to reveal the specific advantages over more traditional methods. Both detailed studies and profiling and screening studies are taken into account. Care was taken to nearly exclusively document well-validated methods outstanding for the analytical challenge discussed. Special attention was paid to aspects exclusive to electromigrative separation techniques, including the use of the mobility axis, the potential for on-site instrumentation, and the capillary format for immunoassays. The review concludes with an introductory guide to method development for different separation modes, presenting typical buffer systems as starting points for different analyte classes. The objective of this review is to provide an orientation for users in separation science considering using capillary electrophoresis in their laboratory in the future.
Collapse
Affiliation(s)
- Tjorben Nils Posch
- Forschungszentrum Jülich GmbH, Central Institute for Engineering, Electronics and Analytics, Analytics ZEA-3, 52425, Jülich, Germany
| | | | | | | |
Collapse
|
7
|
Wu Q, Yu X, Wang Y, Gu X, Ma X, Lv W, Chen Z, Yan C. Pressurized CEC coupled with QTOF-MS for urinary metabolomics. Electrophoresis 2014; 35:2470-8. [PMID: 24789083 DOI: 10.1002/elps.201400117] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2014] [Revised: 04/19/2014] [Accepted: 04/19/2014] [Indexed: 11/09/2022]
Affiliation(s)
- Qian Wu
- School of Pharmacy; Shanghai Jiao Tong University; Shanghai China
| | - Xinwei Yu
- School of Pharmacy; Shanghai Jiao Tong University; Shanghai China
| | - Yan Wang
- School of Pharmacy; Shanghai Jiao Tong University; Shanghai China
| | - Xue Gu
- School of Pharmacy; Shanghai Jiao Tong University; Shanghai China
| | - Xiaoqiong Ma
- Zhejiang Provincial Hospital of Traditional Chinese Medicine; Zhejiang Chinese Medical University; Hangzhou China
| | - Wang Lv
- Zhejiang Provincial Hospital of Traditional Chinese Medicine; Zhejiang Chinese Medical University; Hangzhou China
| | - Zhe Chen
- Zhejiang Provincial Hospital of Traditional Chinese Medicine; Zhejiang Chinese Medical University; Hangzhou China
| | - Chao Yan
- School of Pharmacy; Shanghai Jiao Tong University; Shanghai China
| |
Collapse
|
8
|
D’Orazio G, Fanali S. Pressurized nano-liquid–junction interface for coupling capillary electrochromatography and nano-liquid chromatography with mass spectrometry. J Chromatogr A 2013; 1317:67-76. [DOI: 10.1016/j.chroma.2013.08.052] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2013] [Revised: 08/12/2013] [Accepted: 08/14/2013] [Indexed: 11/30/2022]
|
9
|
Hendrickx A, Klerck KD, Mangelings D, Clincke L, Heyden YV. Three versus five micrometer chlorinated polysaccharide-based packings in chiral capillary electrochromatography: efficiency and precision evaluation. Biomed Chromatogr 2013; 28:168-81. [DOI: 10.1002/bmc.3071] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2013] [Revised: 09/16/2013] [Accepted: 09/20/2013] [Indexed: 11/10/2022]
Affiliation(s)
- Ans Hendrickx
- Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research; Vrije Universiteit Brussel-VUB; Brussels Belgium
| | - Katrijn De Klerck
- Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research; Vrije Universiteit Brussel-VUB; Brussels Belgium
| | - Debby Mangelings
- Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research; Vrije Universiteit Brussel-VUB; Brussels Belgium
| | - Lies Clincke
- Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research; Vrije Universiteit Brussel-VUB; Brussels Belgium
| | - Yvan Vander Heyden
- Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research; Vrije Universiteit Brussel-VUB; Brussels Belgium
| |
Collapse
|
10
|
Akamatsu S, Mitsuhashi T. Simultaneous determination of pharmaceutical components in dietary supplements for weight loss by capillary electrophoresis tandem mass spectrometry. Drug Test Anal 2013; 6:426-33. [DOI: 10.1002/dta.1524] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2013] [Revised: 07/04/2013] [Accepted: 07/13/2013] [Indexed: 11/11/2022]
Affiliation(s)
- Shigeki Akamatsu
- Hyogo Prefectural Institute of Public Health and Consumer Sciences; 2-1-29, Arata-cho, Hyogo-ku; Kobe; 652-0032; Japan
| | - Takao Mitsuhashi
- Hyogo Prefectural Institute of Public Health and Consumer Sciences; 2-1-29, Arata-cho, Hyogo-ku; Kobe; 652-0032; Japan
| |
Collapse
|
11
|
Tak YH, Toraño JS, Somsen GW, de Jong GJ. Optimization of in-line fritless solid-phase extraction for capillary electrophoresis–mass spectrometry. J Chromatogr A 2012; 1267:138-43. [DOI: 10.1016/j.chroma.2012.08.067] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2012] [Revised: 08/17/2012] [Accepted: 08/21/2012] [Indexed: 10/27/2022]
|
12
|
Analysis of synthetic cannabinoids in herbal blends by means of nano-liquid chromatography. J Pharm Biomed Anal 2012; 71:45-53. [DOI: 10.1016/j.jpba.2012.08.008] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2012] [Revised: 08/04/2012] [Accepted: 08/07/2012] [Indexed: 10/28/2022]
|
13
|
Hezinová V, Aturki Z, Klepárník K, D'Orazio G, Foret F, Fanali S. Simultaneous analysis of cocaine and its metabolites in urine by capillary electrophoresis-electrospray mass spectrometry using a pressurized liquid junction nanoflow interface. Electrophoresis 2012; 33:653-60. [DOI: 10.1002/elps.201100410] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
14
|
In-line solid-phase extraction-capillary electrophoresis coupled with mass spectrometry for determination of drugs of abuse in human urine. Anal Bioanal Chem 2012; 403:777-84. [PMID: 22370589 DOI: 10.1007/s00216-012-5872-3] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2011] [Revised: 02/09/2012] [Accepted: 02/14/2012] [Indexed: 10/28/2022]
Abstract
In-line solid-phase extraction-capillary electrophoresis coupled with mass spectrometric detection (SPE-CE-MS) has been used for determination of 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), codeine (COD), hydrocodeine (HCOD), and 6-acetylmorphine (6AM) in urine. The preconcentration system consists of a small capillary filled with Oasis HLB sorbent and inserted into the inlet section of the electrophoresis capillary. The SPE-CE-MS experimental conditions were optimized as follows: the sample (adjusted to pH 6.0) was loaded at 930 mbar for 60 min, elution was performed with methanol at 50 mbar for 35 s, 60 mmol L(-1) ammonium acetate at pH 3.8 was used as running buffer, the separation voltage was 30 kV, and the sheath liquid at a flow rate of 5.0 μL min(-1) was isopropanol-water 50:50 (v/v) containing 0.5% acetic acid. Analysis of urine samples spiked with the four drugs and diluted 1:1 (v/v) was studied in the linear range 0.08-10 ng mL(-1). Detection limits (LODs) (S/N = 3) were between 0.013 and 0.210 ng mL(-1). Repeatability (expressed as relative standard deviation) was below 7.2%. The method developed enables simple and effective determination of these drugs of abuse in urine samples at the levels encountered in toxicology and doping.
Collapse
|
15
|
Pascali JP, Bortolotti F, Tagliaro F. Recent advances in the application of CE to forensic sciences, an update over years 2009-2011. Electrophoresis 2011; 33:117-26. [DOI: 10.1002/elps.201100463] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
16
|
Rabanes HR, Guidote AM, Quirino JP. Capillary electrophoresis of natural products: Highlights of the last five years (2006-2010). Electrophoresis 2011; 33:180-95. [DOI: 10.1002/elps.201100223] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2011] [Revised: 09/22/2011] [Accepted: 09/22/2011] [Indexed: 12/14/2022]
|
17
|
Bragg W, Shamsi SA. Development of a fritless packed column for capillary electrochromatography-mass spectrometry. J Chromatogr A 2011; 1218:8691-700. [PMID: 22035695 DOI: 10.1016/j.chroma.2011.09.060] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2011] [Revised: 09/23/2011] [Accepted: 09/23/2011] [Indexed: 11/25/2022]
Abstract
A novel procedure was developed for the fabrication of a fritless packed column for the coupling of capillary electrochromatography (CEC) to mass spectrometry (MS). The process involved the formation of internal tapers on two separate columns. Once the internal tapers are formed and the columns are packed, the untapered ends of each column were joined together by a commercially available connector. Several advantages of the fritless columns are described. First, the design used here eventually eliminates the need for any frits thus reducing the possibility of bubble formation seen with fritted packed columns. In addition, this is the first report in which the internal tapers are formed at both the inlet and outlet column ends making the fritless CEC-MS column more robust compared to only one report with externally tapered counterparts. Second, a comparison of internally tapered single frit packed CEC-MS (previously developed in our laboratory) column versus fritless CEC-MS column reported here shows that the latter provides better efficiency, suggesting no dead volume with equally good sensitivity and chiral resolution of (±)-aminoglutethimide. The fritless column procedure is universal and was used to prepare a series of columns with a variety of commercially available packing material (mixed mode strong cation exchange, SCX; mixed mode strong anion exchange, SAX; C-18) for the separation and MS detection of short chain non-chromophoric polar amines, long chain nonchromophic anionic surfactant as well as oligomers of non-chromophoric non-ionic surfactants, respectively. The fritless columns showed good intra-day repeatability and inter-day reproducibility of retention times, chiral and achiral resolutions and peak areas. Very satisfactory column-to-column and operator-to-operator reproducibility was demonstrated.
Collapse
Affiliation(s)
- William Bragg
- Department of Chemistry, Center for Biotechnology and Drug Design, Georgia State University, Atlanta, GA 30302, USA
| | | |
Collapse
|
18
|
Abstract
MS has evolved as a critical component in metabolomics, which seeks to answer biological questions through large-scale qualitative and quantitative analyses of the metabolome. MS-based metabolomics techniques offer an excellent combination of sensitivity and selectivity, and they have become an indispensable platform in biology and metabolomics. In this minireview, various MS technologies used in metabolomics are briefly discussed, and future needs are suggested.
Collapse
Affiliation(s)
- Zhentian Lei
- From the Plant Biology Division, The Samuel Roberts Noble Foundation, Ardmore, Oklahoma 73402
| | - David V. Huhman
- From the Plant Biology Division, The Samuel Roberts Noble Foundation, Ardmore, Oklahoma 73402
| | - Lloyd W. Sumner
- From the Plant Biology Division, The Samuel Roberts Noble Foundation, Ardmore, Oklahoma 73402
| |
Collapse
|
19
|
Chen ML, Suo LL, Gao Q, Feng YQ. Determination of eight illegal drugs in human urine by combination of magnetic solid-phase extraction with capillary zone electrophoresis. Electrophoresis 2011; 32:2099-106. [PMID: 21766481 DOI: 10.1002/elps.201100215] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2011] [Revised: 05/06/2011] [Accepted: 05/08/2011] [Indexed: 11/07/2022]
Abstract
Using magnetite/silica/poly(methacrylic acid-co-ethylene glycol dimethacrylate) (Fe(3)O(4)/SiO(2)/poly(MAA-co-EDMA)) magnetic microspheres, a rapid and high-throughput magnetic solid-phase extraction coupled with capillary zone electrophoresis (MSPE-CZE) method was developed for the determination of illegal drugs (ketamine, amphetamines, opiates, and metabolites). The MSPE of target analytes could be completed within 2 min, and the eight target analytes could be baseline separated within 15 min by CZE with 30 mM phosphate buffer solution (PBS, pH 2.0) containing 15% v/v ACN as background electrolyte. Furthermore, hydrodynamic injection with field-amplified sample stacking (FASS) was employed to enhance the sensitivity of this MSPE-CZE method. Under such optimal conditions, the limits of detection for the eight target analytes ranged from 0.015 to 0.105 μg/mL. The application feasibility of MSPE-CZE in illegal drugs monitoring was demonstrated by analyzing urine samples, and the recoveries of target drugs for the spiked sample ranging from 85.4 to 110.1%. The method reproducibility was tested by evaluating the intra- and interday precisions, and relative standard deviations of <10.3 and 12.4%, respectively, were obtained. To increase throughput of the analysis, a home-made MSPE array that has potential application to the treatment of 96 samples simultaneously was used.
Collapse
Affiliation(s)
- Ming-Luan Chen
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan, PR China
| | | | | | | |
Collapse
|
20
|
Lu M, Li Q, Lai Y, Zhang L, Qiu B, Chen G, Cai Z. Determination of stimulants and narcotics as well as their in vitro metabolites by online CE-ESI-MS. Electrophoresis 2011; 32:472-8. [PMID: 21254133 DOI: 10.1002/elps.201000453] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2010] [Revised: 11/12/2010] [Accepted: 11/27/2010] [Indexed: 11/06/2022]
Abstract
A simple, rapid and sensitive CE-ESI-MS method for the simultaneous analysis of seven stimulants and narcotics (amphetamine, ephedrine, methadone, pethidine, tetracaine, codeine and heroin) was developed. The CE-ESI-MS experimental conditions were optimized as follows: 20 mmol/L ammonium acetate with pH 9.0 as running buffer, the separation voltage of 22 kV and the sheath liquid of isopropanol/water (1:1 v/v) containing 7.5 mmol/L acetic acid with 3.0 μL/min flow rate. Under the optimized conditions, the stimulants and narcotics were well separated within 4.6 min using a 70-cm length fused-silica capillary (50 μm id). The detection limits (S/N=3) of the CE-ESI-MS analysis were in the range of 0.40-1.0 ng/mL. Method repeatability of intra-day and inter-day was satisfactory. The recoveries obtained from the analysis of spiked urine samples were between 84.1 and 108%. The developed method was successfully applied for the simultaneous analysis of methadone, pethidine and codeine and their in vitro metabolites.
Collapse
Affiliation(s)
- Minghua Lu
- Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fuzhou University, Fuzhou, PR China
| | | | | | | | | | | | | |
Collapse
|
21
|
Current Awareness in Drug Testing and Analysis. Drug Test Anal 2010. [DOI: 10.1002/dta.66] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|