1
|
Ristori T, Vigliotti A, Baaijens FPT, Loerakker S, Deshpande VS. Prediction of Cell Alignment on Cyclically Strained Grooved Substrates. Biophys J 2017; 111:2274-2285. [PMID: 27851949 DOI: 10.1016/j.bpj.2016.09.052] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2016] [Revised: 09/13/2016] [Accepted: 09/28/2016] [Indexed: 11/27/2022] Open
Abstract
Cells respond to both mechanical and topographical stimuli by reorienting and reorganizing their cytoskeleton. Under certain conditions, such as for cells on cyclically stretched grooved substrates, the effects of these stimuli can be antagonistic. The biophysical processes that lead to the cellular reorientation resulting from such a competition are not clear yet. In this study, we hypothesized that mechanical cues and the diffusion of the intracellular signal produced by focal adhesions are determinants of the final cellular alignment. This hypothesis was investigated by means of a computational model, with the aim to simulate the (re)orientation of cells cultured on cyclically stretched grooved substrates. The computational results qualitatively agree with previous experimental studies, thereby supporting our hypothesis. Furthermore, cellular behavior resulting from experimental conditions different from the ones reported in the literature was simulated, which can contribute to the development of new experimental designs.
Collapse
Affiliation(s)
- Tommaso Ristori
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Institute for Complex Molecular Systems, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Andrea Vigliotti
- Innovative Materials Laboratory, Italian Aerospace Research Centre, Capua, Italy
| | - Frank P T Baaijens
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Institute for Complex Molecular Systems, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Sandra Loerakker
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Institute for Complex Molecular Systems, Eindhoven University of Technology, Eindhoven, the Netherlands.
| | - Vikram S Deshpande
- Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| |
Collapse
|
2
|
Liu H, Yi Q, Liao Y, Feng J, Qiu M, Tang L. Characterizing the role of mechanical signals in gene regulatory networks using Long SAGE. Gene 2012; 501:153-63. [PMID: 22525039 DOI: 10.1016/j.gene.2012.04.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2011] [Revised: 02/13/2012] [Accepted: 04/05/2012] [Indexed: 12/18/2022]
Abstract
A systems understanding of mechanical regulation is critical for determining how cells proliferate and differentiate. To better understand the biological process in which mechanical signals regulate cells, we globally investigated the gene expression profiling via long serial analysis of gene expression (Long SAGE) in osteoblasts after exposure to mechanical stretching. The analysis showed that the differentially expressed genes were related with many physiological processes, including signal transduction, cell proliferation and apoptosis. Several genes that were seldom or never studied in osteoblasts have been found in this study. We further analyzed the signal pathways and provided gene regulatory networks activated by mechanical signals. Many changed genes in our data were contributed to ECM-integrin-FAK mediated pathway and mainly influenced actin-cytoskeleton dynamic remodeling, cell proliferation and differentiation. We also provided evidence supporting the hypothesis that endoplasmic reticulum and mitochondrion were combined to dedicate to calcium regulation. Taken together, our experiments provided a systemic view on biological processes and mechanotransduction network in osteoblasts, suggesting that mechanical signals regulate osteoblast through a greater diversity of interactions and pathways than previously appreciated.
Collapse
Affiliation(s)
- Huan Liu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044, China
| | | | | | | | | | | |
Collapse
|
3
|
Kokkonen H, Verhoef R, Kauppinen K, Muhonen V, Jørgensen B, Damager I, Schols HA, Morra M, Ulvskov P, Tuukkanen J. Affecting osteoblastic responses with in vivo engineered potato pectin fragments. J Biomed Mater Res A 2011; 100:111-9. [DOI: 10.1002/jbm.a.33240] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2010] [Revised: 06/21/2011] [Accepted: 07/27/2011] [Indexed: 11/08/2022]
|
4
|
Green ME, Goforth PB, Satin LS, Love BJ. An integrated instrument for rapidly deforming living cells using rapid pressure pulses and simultaneously monitoring applied strain in near real time. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2010; 81:125102. [PMID: 21198046 PMCID: PMC3017568 DOI: 10.1063/1.3520135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2010] [Accepted: 11/03/2010] [Indexed: 05/30/2023]
Abstract
Because many types of living cells are sensitive to applied strain, different in vitro models have been designed to elucidate the cellular and subcellular processes that respond to mechanical deformation at both the cell and tissue level. Our focus was to improve upon an already established strain system to make it capable of independently monitoring the deflection and applied pressure delivered to specific wells of a commercially available, deformable multiwell culture plate. To accomplish this, we devised a custom frame that was capable of mounting deformable 6 or 24 well plates, a pressurization system that could load wells within the plates, and a camera-based imaging system which was capable of capturing strain responses at a sufficiently high frame rate. The system used a user defined program constructed in Labview(®) to trigger plate pressurization while simultaneously allowing the deflection of the silicone elastomeric plate bottoms to be imaged in near real time. With this system, up to six wells could be pulsed simultaneously using compressed air or nitrogen. Digital image capture allowed near-real time monitoring of applied strain, strain rate, and the cell loading profiles. Although our ultimate goal is to determine how different strain rates applied to neurons modulates their intrinsic biochemical cascades, the same platform technology could be readily applied to other systems. Combining commercially available, deformable multiwell plates with a simple instrument having the monitoring capabilities described here should permit near real time calculations of stretch-induced membrane strain in multiple wells in real time for a wide variety of applications, including high throughput drug screening.
Collapse
Affiliation(s)
- M E Green
- Department of Materials Science and Engineering, The University of Michigan, Ann Arbor, Michigan 48109, USA
| | | | | | | |
Collapse
|
5
|
Sato N, Kubo K, Yamada M, Hori N, Suzuki T, Maeda H, Ogawa T. Osteoblast mechanoresponses on Ti with different surface topographies. J Dent Res 2009; 88:812-6. [PMID: 19767577 DOI: 10.1177/0022034509343101] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
During implant healing, mechanical force is transmitted to osteogenic cells via implant surfaces with various topographies. This study tested a hypothesis that osteoblasts respond to mechanical stimulation differently on titanium with different surface topographies. Rat bone-marrow-derived osteoblastic cells were cultured on titanium disks with machined or acid-etched surfaces. A loading session consisted of a 3-minute application of a 10- or 20-mum-amplitude vibration. Alkaline phosphatase activity and gene expression increased only when the cells were loaded in 3 sessions/day on machined surfaces, regardless of the vibration amplitude, whereas they were increased with 1 loading session/day on the acid-etched surface. The loading did not affect the osteoblast proliferation on either surface, but selectively enhanced the cell spreading on the machined surface. Analysis of the data suggests that osteoblastic differentiation is promoted by mechanical stimulation on titanium, and that the promotion is disproportionate, depending on the titanium surface topography. The frequency of mechanical stimulation, rather than its amplitude, seemed to have a key role.
Collapse
Affiliation(s)
- N Sato
- Laboratory of Bone and Implant Sciences, Weintraub Center for Reconstructive Biotechnology, Division of Advanced Prosthodontics, Biomaterials and Hospital Dentistry, UCLA School of Dentistry, 10833 Le Conte Avenue (B3-81 CHS), Box 951668, Los Angeles, CA 90095-1668, USA
| | | | | | | | | | | | | |
Collapse
|
6
|
Kokkinos PA, Zarkadis IK, Kletsas D, Deligianni DD. Effects of physiological mechanical strains on the release of growth factors and the expression of differentiation marker genes in human osteoblasts growing on Ti-6Al-4V. J Biomed Mater Res A 2009; 90:387-95. [PMID: 18523952 DOI: 10.1002/jbm.a.32105] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Mechanical loading factors at the bone-implant interface are critical for the osseointegration and clinical success of the implant. The aim of the present investigation was to study the effects of mechanical strain on the orthopedic biomaterial Ti-6Al-4V/osteoblast interface, using an in vitro model. Homogeneous strain was applied to human bone marrow derived osteoblasts (HBMDOs) cultured on Ti-6Al-4V, at physiological levels (strain magnitudes 500 microstrain (microepsilon) and 1000 microepsilon, at frequencies of load application 0.5 Hz and 1 Hz), by a mechanostimulatory system, based on the principle of four-point bending. Semi-quantitative reverse transcription-polymerase chain reaction (sqRT-PCR) was used to determine the mRNA expression of Cbfa1 and osteocalcin at different loading conditions. The release of growth factors as a response to stretch was also investigated by transferring stretch-conditioned media to nonstretched cells and by measuring their effect on the regulation of DNA synthesis. Mechanical loading was found to contribute to the regulation of osteoblast differentiation by influencing the level of the osteoblast-specific transcription factor Cbfa1, both at the mRNA and protein level, and also the level of osteocalcin, which is regarded as the most osteoblast-specific gene. Both genes were differentially expressed shortly after the application of different mechanical stimuli, in terms of strain frequency, magnitude, and time interval. Media conditioned from mechanically stressed HBMDOs stimulate DNA synthesis more intensely compared to media conditioned from unstressed control cultures, indicating that mechanical strain induces the release of a mitogenic potential that regulates cell proliferation.
Collapse
Affiliation(s)
- Petros A Kokkinos
- Biomedical Engineering Laboratory, Department of Mechanical Engineering and Aeronautics, University of Patras, Rion GR 26500 Patra, Greece
| | | | | | | |
Collapse
|
7
|
Kokkinos PA, Zarkadis IK, Panidis TT, Deligianni DD. Estimation of hydrodynamic shear stresses developed on human osteoblasts cultured on Ti-6Al-4V and strained by four point bending. Effects of mechanical loading to specific gene expression. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2009; 20:655-665. [PMID: 18941870 DOI: 10.1007/s10856-008-3602-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2008] [Accepted: 09/23/2008] [Indexed: 05/26/2023]
Abstract
The aim of the present investigation was to study the effects of mechanical strain on the orthopedic biomaterial Ti-6Al-4V-osteoblast interface, using an in vitro model. Homogeneous strain was applied to Human Bone Marrow derived Osteoblasts (HBMDOs) cultured on Ti-6Al-4V, at levels which are considered physiological, by a four-point bending mechanostimulatory system. A simple model for the estimation of maximum hydrodynamic shear stresses developed on cell culture layer and induced by nutrient medium flow during mechanical loading, as a function of the geometry of the culture plate and the load characteristics, is proposed. Shear stresses were lower than those which can elicit cell response. Mechanical loading was found that contributes to the regulation of osteoblast differentiation by influencing the expression of the osteoblast-specific transcription factor Cbfa1, both at the mRNA and protein level, and also the osteocalcin expression, whereas osteopontin gene expression was unaffected by mechanical loading at all experimental conditions.
Collapse
Affiliation(s)
- Petros A Kokkinos
- Biomedical Engineering Laboratory, Department of Mechanical Engineering and Aeronautics, University of Patras, Rion, 26500, Patra, Greece
| | | | | | | |
Collapse
|
8
|
Naito K, Matsuzaka K, Ishigami K, Inoue T. Mechanical force promotes proliferation and early differentiation of bone marrow derived osteoblast-like cells in vitro. ACTA ACUST UNITED AC 2009. [DOI: 10.3353/omp.13.143] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
9
|
Affiliation(s)
- Adele L Boskey
- Musculoskeletal Integrity Program, Hospital for Special Surgery, 535 East 70th Street, New York, New York 10021, USA.
| | | |
Collapse
|
10
|
Kokkonen H, Cassinelli C, Verhoef R, Morra M, Schols HA, Tuukkanen J. Differentiation of Osteoblasts on Pectin-Coated Titanium. Biomacromolecules 2008; 9:2369-76. [DOI: 10.1021/bm800356b] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- H. Kokkonen
- Department of Anatomy and Cell Biology, University of Oulu, Post Office Box 5000, 90014 Oulu, Finland, Nobil Bio Ricerche, Str. S. Rocco 36, 14018 Villafranca d‘Asti, Italy, and Laboratory of Food Chemistry, Wageningen University, Bomenweg 2, 6703HD Wageningen, The Netherlands
| | - C. Cassinelli
- Department of Anatomy and Cell Biology, University of Oulu, Post Office Box 5000, 90014 Oulu, Finland, Nobil Bio Ricerche, Str. S. Rocco 36, 14018 Villafranca d‘Asti, Italy, and Laboratory of Food Chemistry, Wageningen University, Bomenweg 2, 6703HD Wageningen, The Netherlands
| | - R. Verhoef
- Department of Anatomy and Cell Biology, University of Oulu, Post Office Box 5000, 90014 Oulu, Finland, Nobil Bio Ricerche, Str. S. Rocco 36, 14018 Villafranca d‘Asti, Italy, and Laboratory of Food Chemistry, Wageningen University, Bomenweg 2, 6703HD Wageningen, The Netherlands
| | - M. Morra
- Department of Anatomy and Cell Biology, University of Oulu, Post Office Box 5000, 90014 Oulu, Finland, Nobil Bio Ricerche, Str. S. Rocco 36, 14018 Villafranca d‘Asti, Italy, and Laboratory of Food Chemistry, Wageningen University, Bomenweg 2, 6703HD Wageningen, The Netherlands
| | - H. A. Schols
- Department of Anatomy and Cell Biology, University of Oulu, Post Office Box 5000, 90014 Oulu, Finland, Nobil Bio Ricerche, Str. S. Rocco 36, 14018 Villafranca d‘Asti, Italy, and Laboratory of Food Chemistry, Wageningen University, Bomenweg 2, 6703HD Wageningen, The Netherlands
| | - J. Tuukkanen
- Department of Anatomy and Cell Biology, University of Oulu, Post Office Box 5000, 90014 Oulu, Finland, Nobil Bio Ricerche, Str. S. Rocco 36, 14018 Villafranca d‘Asti, Italy, and Laboratory of Food Chemistry, Wageningen University, Bomenweg 2, 6703HD Wageningen, The Netherlands
| |
Collapse
|
11
|
Shalabi MM, Wolke JGC, Cuijpers VMJI, Jansen JA. Evaluation of bone response to titanium-coated polymethyl methacrylate resin (PMMA) implants by X-ray tomography. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2007; 18:2033-9. [PMID: 17558472 DOI: 10.1007/s10856-007-3160-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2006] [Accepted: 08/21/2006] [Indexed: 05/15/2023]
Abstract
High-resolution three-dimensional data about the bone response to oral implants can be obtained by using microfocus computer tomography. However, a disadvantage is that metallic implants cause streaking artifacts due to scattering of X-rays, which prevents an accurate evaluation of the interfacial bone-to-implant contact. It has been suggested that the use of thin titanium coatings deposited on polymeric implants can offer an alternative option for analyzing bone contact using micro-CT imaging. Consequently, the aim of the current study was to investigate bone behavior to titanium-coated polymethylmethacrylate (PMMA) implants by micro-CT and histological evaluation. For the experiment titanium-coated PMMA implants were used. The implants had a machined threaded appearance and were provided with a 400-500 nm thick titanium coating. The implants were inserted in the right or left tibia of 10 goats. After an implantation period of 12 weeks the implants were retrieved and prepared for micro-computer tomography (microCT), light microscopy, and X-ray microanalysis. The micro-CT showed that the screw-threads and typical implant configuration were well maintained through the installation procedure. Overall, histological responses showed that the titanium-coated implants were well tolerated and caused no atypical tissue response. In addition, the bone was seen in direct contact with the titanium-coated layer. The X-ray microanalysis results confirmed the light microscopical data. In conclusion, the obtained results proof the final use of titanium-coated PMMA implants for evaluation of the bone-implant response using microCT. However, this study also confirms that for a proper analysis of the bone-implant interface the additional use of microscopical techniques is still required.
Collapse
Affiliation(s)
- Manal M Shalabi
- Department of Periodontology and Biomaterials, Dentistry 309, Radboud University Nijmegen Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | | | | | | |
Collapse
|
12
|
Siebers MC, Walboomers XF, Leewenburgh SCG, Wolke JCG, Boerman OC, Jansen JA. Transforming growth factor-beta1 release from a porous electrostatic spray deposition-derived calcium phosphate coating. ACTA ACUST UNITED AC 2006; 12:2449-56. [PMID: 16995778 DOI: 10.1089/ten.2006.12.2449] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
This study evaluated the utilization of a porous coating, derived with electrostatic spray deposition (ESD), as a carrier material for transforming growth factor-beta1 (TGF-beta1). A porous beta-tricalcium phosphate coating was deposited with ESD, and 10 ng of (125) I-labeled TGF-beta1 was loaded on the substrates. A burst release during the first hour of incubation of >90% was observed, in either culture medium or phosphate-buffered saline (PBS). Ninety-nine percent of the growth factor was released after 10 days of incubation. All samples were able to inhibit epithelial cell growth, indicating that the growth factor had remained bioactive after release. Thereafter, osteoblast-like cells were seeded upon substrates with or without 10 ng of TGF-beta1. While proliferation of osteoblast-like cells was increased on TGF-beta1-loaded substrates, differentiation was inhibited or delayed. In conclusion, a porous ESD-derived calcium phosphate coating can be used as a carrier material for TGF-beta1, when a burst release is desired.
Collapse
Affiliation(s)
- Marijke C Siebers
- Department of Periodontology and Biomaterials, Radboud University Nijmegen Medical Centre, Nijmegen, the Netherlands
| | | | | | | | | | | |
Collapse
|
13
|
Bartold PM, Xiao Y, Lyngstaadas SP, Paine ML, Snead ML. Principles and applications of cell delivery systems for periodontal regeneration. Periodontol 2000 2006; 41:123-35. [PMID: 16686930 DOI: 10.1111/j.1600-0757.2006.00156.x] [Citation(s) in RCA: 77] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- P Mark Bartold
- Colgate Australian Clinical Dental Research Centre, Dental School, University of Adelaide, Adelaide, South Australia, Australia
| | | | | | | | | |
Collapse
|
14
|
Loesberg WA, Walboomers XF, van Loon JJWA, Jansen JA. The effect of combined cyclic mechanical stretching and microgrooved surface topography on the behavior of fibroblasts. J Biomed Mater Res A 2006; 75:723-32. [PMID: 16110493 DOI: 10.1002/jbm.a.30480] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Under the influence of mechanical stress, cultured fibroblasts have a tendency to orient themselves perpendicular to the stress direction. Similar cell alignment can be induced by guiding cells along topographical clues, like microgrooves. The aim of this study was to evaluate cell behavior on microgrooved substrates, exposed to cyclic stretching. We hypothesized that cellular shape is mainly determined by topographical clues. On basis of earlier studies, a 10-microm wide square groove, and a 40-microm wide V-shaped groove pattern were used. Smooth substrates served as controls. Onto all substrates fibroblasts were cultured and 1-Hz cyclic stretching was applied (0, 4, or 8%) for 3-24 h. Cells were prepared for scanning electron microscopy, immunostaining of filamentous actin, alignment measurements, and PCR (collagen-I, fibronectin, alpha1- and beta1-integrins). Results showed that cells aligned on all grooved surfaces, and fluorescence microscopy showed similar orientation of intracellular actin filaments. After 3 h of stretch, cellular orientation started to commence, and after 24 h the cells had aligned themselves almost entirely. Image analysis showed better orientation with increasing groove depth. Statistical testing proved that the parameters groove type, groove orientation, and time all were significant, but the variation of stretch force was not. Substrates with microgrooves perpendicular to the stretch direction elicit a better cell alignment. The expression of beta1-integrin and collagen-I was higher in the stretched samples. In conclusion, we can maintain our hypothesis, as microgrooved topography was most effective in applying strains relative to the long axis of the cell, and only secondary effects of stretch force were present.
Collapse
Affiliation(s)
- W A Loesberg
- Radboud University Nijmegen Medical Centre, Department of Periodontology & Biomaterials, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands
| | | | | | | |
Collapse
|
15
|
Loesberg WA, Walboomers XF, van Loon JJWA, Jansen JA. The effect of combined hypergravity and microgrooved surface topography on the behaviour of fibroblasts. ACTA ACUST UNITED AC 2006; 63:384-94. [PMID: 16607630 DOI: 10.1002/cm.20132] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
This study evaluated in vitro the differences in morphological behaviour between fibroblast cultured on smooth and micro-grooved substrata (groove depth: 1 mum, width: 1, 2, 5, 10 microm), which undergo artificial hypergravity by centrifugation (10, 24 and 50 g; or 1 g control). The aim of the study was to clarify which of these parameters was more important to determine cell behaviour. Morphological characteristics were investigated using scanning electron microscopy and fluorescence microscopy in order to obtain qualitative information on cell spreading and alignment. Confocal laser scanning microscopy visualised distribution of actin filaments and vinculin anchoring points through immunostaining. Finally, expression of collagen type I, fibronectin, and alpha(1)- and beta(1)-integrin were investigated by PCR. Microscopy and image analysis showed that the fibroblasts aligned along the groove direction on all textured surfaces. On the smooth substrata (control), cells spread out in a random fashion. The alignment of cells cultured on grooved surfaces increased with higher g-forces until a peak value at 25 g. An ANOVA was performed on the data, for all main parameters: topography, gravity force, and time. In this analysis, all parameters proved significant. In addition, most gene levels were reduced by hypergravity. Still, collagen type 1 and fibronectin are seemingly unaffected by time or force. From our data it is concluded that the fibroblasts primarily adjust their shape according to morphological environmental cues like substratum surface whilst a secondary, but significant, role is played by hypergravity forces.
Collapse
Affiliation(s)
- W A Loesberg
- Department of Periodontology and Biomaterials, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
| | | | | | | |
Collapse
|
16
|
Walboomers XF, Elder SE, Bumgardner JD, Jansen JA. Hydrodynamic compression of young and adult rat osteoblast-like cells on titanium fiber mesh. J Biomed Mater Res A 2006; 76:16-24. [PMID: 16250009 DOI: 10.1002/jbm.a.30304] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Living bone cells are responsive to mechanical loading. Consequently, numerous in vitro models have been developed to examine the application of loading to cells. However, not all systems are suitable for the fibrous and porous three-dimensional materials, which are preferable for tissue repair purposes, or for the production of tissue engineering scaffolds. For three-dimensional applications, mechanical loading of cells with either fluid flow systems or hydrodynamic pressure systems has to be considered. Here, we aimed to evaluate the response of osteoblast-like cells to hydrodynamic compression, while growing in a three-dimensional titanium fiber mesh scaffolding material. For this purpose, a custom hydrodynamic compression chamber was built. Bone marrow cells were obtained from the femora of young (12-day-old) or old (1-year-old) rats, and precultured in the presence of dexamethasone and beta-glycerophosphate to achieve an osteoblast-like phenotype. Subsequently, cells were seeded onto the titanium mesh scaffolds, and subjected to hydrodynamic pressure, alternating between 0.3 to 5.0 MPa at 1 Hz, at 15-min intervals for a total of 60 min per day for up to 3 days. After pressurization, cell viability was checked. Afterward, DNA levels, alkaline phosphatase (ALP) activity, and extracellular calcium content were measured. Finally, all specimens were observed with scanning electron microscopy. Cell viability studies showed that the applied pressure was not harmful to the cells. Furthermore, we found that cells were able to detect the compression forces, because we did see evident effects on the cell numbers of the cells derived from old animals. However, there were no other changes in the cells under pressure. Finally, it was also noticeable that cells from old animals did not express ALP activity, but did show similar calcified extracellular matrix formation to the cells from young animals. In conclusion, the difference in DNA levels as reaction toward pressure, and the difference in ALP levels, suggest that the osteogenic properties of bone marrow-derived osteoblast-like cells are different with respect to the age of the donor.
Collapse
Affiliation(s)
- X F Walboomers
- Department of Biomaterials, University Medical Center, College of Dental Science, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands
| | | | | | | |
Collapse
|