1
|
McCandless BA, Raum K, Muller M. The respective and dependent effects of scattering and bone matrix absorption on ultrasound attenuation in cortical bone. Phys Med Biol 2024; 69:115018. [PMID: 38631364 DOI: 10.1088/1361-6560/ad3fff] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 04/17/2024] [Indexed: 04/19/2024]
Abstract
Cortical bone is characterized by a dense solid matrix permeated by fluid-filled pores. Ultrasound scattering has potential for the non-invasive evaluation of changes in bone porosity. However, there is an incomplete understanding of the impact of ultrasonic absorption in the solid matrix on ultrasound scattering. In this study, maps were derived from scanning acoustic microscopy images of human femur cross-sections. Finite-difference time domain ultrasound scatter simulations were conducted on these maps. Pore density, diameter distribution of the pores, and nominal absorption values in the solid and fluid matrices were controlled. Ultrasound pulses with a central frequency of 8.2 MHz were propagated, both in through-transmission and backscattering configurations. From these data, the scattering, bone matrix absorption, and attenuation extinction lengths were calculated. The results demonstrated that as absorption in the solid matrix was varied, the scattering, absorption, and attenuation extinction lengths were significantly impacted. It was shown that for lower values of absorption in the solid matrix (less than 2 dB mm-1), attenuation due to scattering dominates, whereas at higher values of absorption (more than 2 dB mm-1), attenuation due to absorption dominates. This will impact how ultrasound attenuation and scattering parameters can be used to extract quantitative information on bone microstructure.
Collapse
Affiliation(s)
- Brett Austin McCandless
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, United States of America
| | - Kay Raum
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Center for Biomedicine, Center for Regenerative Therapies, D-12203 Berlin, Germany
| | - Marie Muller
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, United States of America
| |
Collapse
|
2
|
Surowiec RK, Does MD, Nyman JS. In Vivo Assessment of Bone Quality Without X-rays. Curr Osteoporos Rep 2024; 22:56-68. [PMID: 38227178 PMCID: PMC11050740 DOI: 10.1007/s11914-023-00856-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/22/2023] [Indexed: 01/17/2024]
Abstract
PURPOSE OF REVIEW This review summarizes recent advances in the assessment of bone quality using non-X-ray techniques. RECENT FINDINGS Quantitative ultrasound (QUS) provides multiple measurements of bone characteristics based on the propagation of sound through bone, the attenuation of that sound, and different processing techniques. QUS parameters and model predictions based on backscattered signals can discriminate non-fracture from fracture cases with accuracy comparable to standard bone mineral density (BMD). With advances in magnetic resonance imaging (MRI), bound water and pore water, or a porosity index, can be quantified in several long bones in vivo. Since such imaging-derived measurements correlate with the fracture resistance of bone, they potentially provide new BMD-independent predictors of fracture risk. While numerous measurements of mineral, organic matrix, and bound water by Raman spectroscopy correlate with the strength and toughness of cortical bone, the clinical assessment of person's bone quality using spatially offset Raman spectroscopy (SORS) requires advanced spectral processing techniques that minimize contaminating signals from fat, skin, and blood. Limiting exposure of patients to ionizing radiation, QUS, MRI, and SORS has the potential to improve the assessment of fracture risk and track changes of new therapies that target bone matrix and micro-structure.
Collapse
Affiliation(s)
- Rachel K Surowiec
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Dr., West Lafayette, IN, 47907, USA
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, 550 N. University Blvd., Indianapolis, IN, 46202, USA
| | - Mark D Does
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN, 37232, USA
- Institute of Imaging Science, Vanderbilt University Medical Center, 1161 21st Ave. S., Nashville, TN, 37232, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, 1161 21st Ave. S., Nashville, TN, 37232, USA
- Department of Electrical Engineering and Computer Science, Vanderbilt University, 400 24th Ave. S., Nashville, TN, 37212, USA
| | - Jeffry S Nyman
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN, 37232, USA.
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Ave. S., Suite 4200, Nashville, TN, 37232, USA.
- Vanderbilt Center for Bone Biology, Vanderbilt University Medical Center, 1211 Medical Center Dr., Nashville, TN, 37212, USA.
- Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, 37212, USA.
| |
Collapse
|
3
|
Marchant JK, Clinard SR, Odéen H, Parker DL, Christensen DA. The influence of bone model geometries on the determination of skull acoustic properties. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3779. [PMID: 37794748 PMCID: PMC10841890 DOI: 10.1002/cnm.3779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 04/06/2023] [Accepted: 09/04/2023] [Indexed: 10/06/2023]
Abstract
In this study, we investigated the impact of various simulated skull bone geometries on the determination of skull speed of sound and acoustic attenuation values via optimization using transmitted pressure amplitudes beyond the bone. Using the hybrid angular spectrum method (HAS), we simulated ultrasound transmission through four model sets of different geometries involving sandwiched layers of diploë and cortical bone in addition to three models generated from CT images of ex-vivo human skull-bones. We characterized cost-function solution spaces for each model and, using optimization, found that when a model possessed appreciable variations in resolvable layer thickness, the predefined attenuation coefficients could be found with low error (RMSE < 0.01 Np/cm). However, we identified a spatial frequency cutoff in the models' geometry beyond which the accuracy of the property determination begins to fail, depending on the frequency of the ultrasound source. There was a large increase in error of the attenuation coefficients determined by the optimization when the variations in layer thickness were above the identified spatial frequency cutoffs, or when the lateral variations across the model were relatively low in amplitude. For our limited sample of three CT-image derived bone models, the attenuation coefficients were determined successfully. The speed of sound values were determined with low error for all models (including the CT-image derived models) that were tested (RMSE < 0.4 m/s). These results illustrate that it is possible to determine the acoustic properties of two-component models when the internal bone structure is taken into account and the structure satisfies the spatial frequency constraints discussed.
Collapse
Affiliation(s)
- Joshua K. Marchant
- Department of Physics and Astronomy, University of Utah, Salt Lake City, UT, USA
| | - Samuel R. Clinard
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Henrik Odéen
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Dennis L. Parker
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Douglas A. Christensen
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
4
|
Yang M, Yin H, Zhen D, Ding Y, Wang Y, Sun L, He F, Tang X. Exposure to famine in every stage of life and the risk of osteoporosis and fractures later in life: A cross-sectional study. Bone 2023; 168:116644. [PMID: 36566820 DOI: 10.1016/j.bone.2022.116644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 11/24/2022] [Accepted: 12/09/2022] [Indexed: 12/24/2022]
Abstract
BACKGROUND AND OBJECTIVE Data on the association between early-life famine exposure and osteoporosis and fractures remain limited and inconclusive. The aim of this study was to investigate the correlation between famine exposure and osteoporosis and fractures. METHODS We performed a cross-sectional analysis using the first follow-up survey data from the China Cardiometabolic Disease and Cancer Cohort Study from 2014 to 2016. We classified 4807 Lanzhou participants into seven groups based on their birthday (non-exposed or exposed in the fetal stage, early childhood, mid-childhood, late childhood, adolescence, or early adulthood). And we combined the non-exposed and early-adulthood exposed groups as a control group, which was called "age balanced group". This age-balanced group was used as the control group to further evaluate the risk of osteoporosis and fracture. We used multiple logistic regression to estimate the association between famine exposure and the risk of osteoporosis (T-score ≤ -1.8 by QUS) and self-reported fracture. RESULTS In women, compared to the age-balanced group, the odds ratios (95 % CI) for the risk of osteoporosis were 1.400(1.034, 1.897), 1.630(1.268, 2.095), 1.707(1.314, 2.218), 2.150(1.732.2.668) and 2.885(2.286,3.641) in the fetal stage, early childhood, mid-childhood, late childhood and adolescence famine-exposed cohorts. In men, no association between famine and osteoporosis was noted with exposed cohort compared with the age-balanced control cohort (p > 0.05). Interestingly, the association between famine exposure and fractures was slightly different from the above results: in women, the odds ratios (95 % CI) for fractures in mid-childhood famine exposure was 1.461(1.082,1.973), in late childhood famine exposure was 1.333(1.035,1.718) and in adolescence famine exposure was 1.607(1.239,2.085). However, compared to the age-balanced control cohort, men exposed to famine in early childhood (OR: 1.801, 95 % CI: 1.010,3.211) had a higher risk of fracture. CONCLUSION Famine exposure in different life stage has adverse effects on bone health. Famine exposure in not only the period from gestation to infancy, but also childhood and adolescence was associated with an increased risk of osteoporosis, especially in women. Exposure to famine in childhood- (mid and late) and adolescence- life period is associated with fracture in women. But, in men early-childhood famine exposure was only associated with fracture.
Collapse
Affiliation(s)
- Mengdi Yang
- First School of Clinical Medicine, Lanzhou University, Donggang West Road, Lanzhou 730000, Gansu, People's Republic of China
| | - Hongtao Yin
- Department of Endocrinology, The First Hospital of Lanzhou University, Donggang West Road, Lanzhou 730000, Gansu, People's Republic of China
| | - Donghu Zhen
- Department of Endocrinology, The First Hospital of Lanzhou University, Donggang West Road, Lanzhou 730000, Gansu, People's Republic of China.
| | - Yulu Ding
- First School of Clinical Medicine, Lanzhou University, Donggang West Road, Lanzhou 730000, Gansu, People's Republic of China
| | - Yujie Wang
- First School of Clinical Medicine, Lanzhou University, Donggang West Road, Lanzhou 730000, Gansu, People's Republic of China
| | - Linnan Sun
- First School of Clinical Medicine, Lanzhou University, Donggang West Road, Lanzhou 730000, Gansu, People's Republic of China
| | - Fengying He
- First School of Clinical Medicine, Lanzhou University, Donggang West Road, Lanzhou 730000, Gansu, People's Republic of China
| | - Xulei Tang
- Department of Endocrinology, The First Hospital of Lanzhou University, Donggang West Road, Lanzhou 730000, Gansu, People's Republic of China
| |
Collapse
|
5
|
Dia AS, Renaud G, Nooghabi AH, Grimal Q. The influence of intra-cortical microstructure on the contrast in ultrasound images of the cortex of long bones: A 2D simulation study. ULTRASONICS 2023; 127:106831. [PMID: 36084514 DOI: 10.1016/j.ultras.2022.106831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 07/14/2022] [Accepted: 08/16/2022] [Indexed: 06/15/2023]
Abstract
Decreased thickness of the bone cortex due to bone loss in the course of ageing and osteoporosis is associated with reduced bone strength. Cortical thickness measurement from ultrasound images was recently demonstrated in young adults. This requires the identification of both the outer (periosteum) and inner (endosteum) surfaces of the bone cortex. However, with bone loss, the cortical porosity and the size of the vascular pores increase resulting in enhanced ultrasound scattering which may prevent the detection of the endosteum. The aim of this work was to study the influence of cortical bone microstructure variables, such as porosity and pore size, on the contrast of the endosteum in ultrasound images. We wanted to estimate the range of these variables for which ultrasound imaging of the endosteum is feasible. We generated synthetic data using a two-dimensional time-domain code to simulate the propagation of elastodynamic waves. A synthetic aperture imaging sequence with an array transducer operating at a center frequency of 2.5 MHz was used. The numerical simulations were conducted for 105 cortical microstructures obtained from high resolution X-ray computed tomography images of ex vivo bone samples with a porosity ranging from 2% to 24 %. Images were reconstructed using a delay-and-sum (DAS) algorithm with optimized f-number, correction of refraction at the periosteum, and sample-specific wave-speed. We observed a range variation of 18 dB of endosteum contrast in our data set depending on the bone microstructure. We found that as porosity increases, speckle intensity inside the bone cortex increases whereas the intensity of the signal from the endosteum decreases. Also, a microstructure with large pores (diameter >250 μm) was associated with poor endosteum visibility, compared with a microstructure with equal porosity but a more narrow distribution of pore sizes. These findings suggest that ultrasound imaging of the bone cortex with a probe operating at a central frequency of 2.5 MHz using refraction-corrected DAS is capable of detecting the endosteum of a cortex with moderate porosity (less than about 10%) if the largest pores remain smaller than about 200 μm.
Collapse
Affiliation(s)
- Amadou Sall Dia
- Sorbonne Université, INSERM, CNRS, Laboratoire d'Imagerie Biomédicale, LIB, F-75006, Paris, France.
| | - Guillaume Renaud
- Sorbonne Université, INSERM, CNRS, Laboratoire d'Imagerie Biomédicale, LIB, F-75006, Paris, France; Department of Imaging Physics, Delft University of Technology, The Netherlands
| | - Aida Hejazi Nooghabi
- Sorbonne Université, INSERM, CNRS, Laboratoire d'Imagerie Biomédicale, LIB, F-75006, Paris, France
| | - Quentin Grimal
- Sorbonne Université, INSERM, CNRS, Laboratoire d'Imagerie Biomédicale, LIB, F-75006, Paris, France
| |
Collapse
|
6
|
Miranda D, Olivares R, Munoz R, Minonzio JG. Improvement of Patient Classification Using Feature Selection Applied to Bidirectional Axial Transmission. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:2663-2671. [PMID: 35914050 DOI: 10.1109/tuffc.2022.3195477] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Osteoporosis is still a worldwide problem, particularly due to associated fragility fractures. Patients at risk of fracture are currently detected using the X-Ray gold standard dual-energy X-ray absorptiometry (DXA), based on a calibrated 2-D image. Different alternatives, such as 3-D X-rays, magnetic resonance imaging (MRI) or ultrasound, have been proposed, the latter having advantages of being portable and sensitive to mechanical and geometrical properties. Bidirectional axial transmission (BDAT) has been used to classify between patients with or without nontraumatic fractures using "classical" ultrasonic parameters, such as velocities, as well as cortical thickness and porosity, obtained from an inverse problems. Recently, complementary parameters acquired with structural and textural analysis of guided wave spectrum images (GWSIs) have been introduced. These parameters are not limited by solution ambiguities, as for inverse problem. The aim of the study is to improve the patient classification using a feature selection strategy for all available ultrasound features completed by clinical parameters. To this end, three classical feature ranking methods were considered: analysis of variance (ANOVA), recursive feature elimination (RFE), and extreme gradient boosting importance feature (XGBI). In order to evaluate the performance of the feature selection techniques, three classical classification methods were used: logistic regression (LR), support vector machine (SVM), and extreme gradient boosting (XGB). The database was obtained from a previous clinical study [Minonzio et al., 2019]. Results indicate that the best accuracy of 71 [66-76]% was achieved by using RFE and SVM with 22 (out of 43) ultrasonic and clinical features. This value outperformed the accuracy of 68 [64-73]% reached with 2 (out of 6) DXA and clinical features. These values open promising perspectives toward improved and generalizable classification of patients at risk of fracture.
Collapse
|
7
|
Estimation of Thickness and Speed of Sound for Transverse Cortical Bone Imaging Using Phase Aberration Correction Methods: An In Silico and Ex Vivo Validation Study. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12105283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Delay-and-sum (DAS) beamforming of backscattered echoes is used for conventional ultrasound imaging. Although DAS beamforming is well suited for imaging in soft tissues, refraction, scattering, and absorption, porous mineralized tissues cause phase aberrations of reflected echoes and subsequent image degradation. The recently developed refraction corrected multi-focus technique uses subsequent focusing of waves at variable depths, the tracking of travel times of waves reflected from outer and inner cortical bone interfaces, the estimation of the shift needed to focus from one interface to another to determine cortical thickness (Ct.Th), and the speed of sound propagating in a radial bone direction (Ct.ν11). The method was validated previously in silico and ex vivo on plate shaped samples. The aim of this study was to correct phase aberration caused by bone geometry (i.e., curvature and tilt with respect to the transducer array) and intracortical pores for the multi-focus approach. The phase aberration correction methods are based on time delay estimation via bone geometry differences to flat bone plates and via the autocorrelation and cross correlation of the reflected ultrasound waves from the endosteal bone interface. We evaluate the multi-focus approach by incorporating the phase aberration correction methods by numerical simulation and one experiment on a human tibia bone, and analyze the precision and accuracy of measuring Ct.Th and Ct.ν11. Site-matched reference values of the cortical thickness of the human tibia bone were obtained from high-resolution peripheral computed tomography. The phase aberration correction methods resulted in a more precise (coefficient of variation of 5.7%) and accurate (root mean square error of 6.3%) estimation of Ct.Th, and a more precise (9.8%) and accurate (3.4%) Ct.ν11 estimation, than without any phase aberration correction. The developed multi-focus method including phase aberration corrections provides local estimations of both cortical thickness and sound velocity and is proposed as a biomarker of cortical bone quality with high clinical potential for the prevention of osteoporotic fractures.
Collapse
|
8
|
Clinical Devices for Bone Assessment. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:35-53. [DOI: 10.1007/978-3-030-91979-5_3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|